WorldWideScience

Sample records for program iris features

  1. Dynamic Features for Iris Recognition.

    Science.gov (United States)

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  2. Feature Vector Construction Method for IRIS Recognition

    Science.gov (United States)

    Odinokikh, G.; Fartukov, A.; Korobkin, M.; Yoo, J.

    2017-05-01

    One of the basic stages of iris recognition pipeline is iris feature vector construction procedure. The procedure represents the extraction of iris texture information relevant to its subsequent comparison. Thorough investigation of feature vectors obtained from iris showed that not all the vector elements are equally relevant. There are two characteristics which determine the vector element utility: fragility and discriminability. Conventional iris feature extraction methods consider the concept of fragility as the feature vector instability without respect to the nature of such instability appearance. This work separates sources of the instability into natural and encodinginduced which helps deeply investigate each source of instability independently. According to the separation concept, a novel approach of iris feature vector construction is proposed. The approach consists of two steps: iris feature extraction using Gabor filtering with optimal parameters and quantization with separated preliminary optimized fragility thresholds. The proposed method has been tested on two different datasets of iris images captured under changing environmental conditions. The testing results show that the proposed method surpasses all the methods considered as a prior art by recognition accuracy on both datasets.

  3. Statistical feature extraction based iris recognition system

    Indian Academy of Sciences (India)

    Iris recognition systems have been proposed by numerous researchers using different feature extraction techniques for accurate and reliable biometric authentication. In this paper, a statistical feature extraction technique based on correlation between adjacent pixels has been proposed and implemented. Hamming ...

  4. Ethnicity distinctiveness through iris texture features using Gabor filters

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu P

    2017-02-01

    Full Text Available Research in iris biometrics has been focused on utilizing iris features as a means of identity verification and authentication. However, not enough research work has been done to explore iris textures to determine soft biometrics such as gender...

  5. Comparison of features response in texture-based iris segmentation

    CSIR Research Space (South Africa)

    Bachoo, A

    2009-03-01

    Full Text Available and eyelashes that corrupt the iris region of interest. An accurate segmentation algorithm must localize and remove these noise components. Texture features are considered in this paper for describing iris and non-iris regions. These regions are classified using...

  6. Iris Recognition Using Feature Extraction of Box Counting Fractal Dimension

    Science.gov (United States)

    Khotimah, C.; Juniati, D.

    2018-01-01

    Biometrics is a science that is now growing rapidly. Iris recognition is a biometric modality which captures a photo of the eye pattern. The markings of the iris are distinctive that it has been proposed to use as a means of identification, instead of fingerprints. Iris recognition was chosen for identification in this research because every human has a special feature that each individual is different and the iris is protected by the cornea so that it will have a fixed shape. This iris recognition consists of three step: pre-processing of data, feature extraction, and feature matching. Hough transformation is used in the process of pre-processing to locate the iris area and Daugman’s rubber sheet model to normalize the iris data set into rectangular blocks. To find the characteristics of the iris, it was used box counting method to get the fractal dimension value of the iris. Tests carried out by used k-fold cross method with k = 5. In each test used 10 different grade K of K-Nearest Neighbor (KNN). The result of iris recognition was obtained with the best accuracy was 92,63 % for K = 3 value on K-Nearest Neighbor (KNN) method.

  7. A multi-approach feature extractions for iris recognition

    Science.gov (United States)

    Sanpachai, H.; Settapong, M.

    2014-04-01

    Biometrics is a promising technique that is used to identify individual traits and characteristics. Iris recognition is one of the most reliable biometric methods. As iris texture and color is fully developed within a year of birth, it remains unchanged throughout a person's life. Contrary to fingerprint, which can be altered due to several aspects including accidental damage, dry or oily skin and dust. Although iris recognition has been studied for more than a decade, there are limited commercial products available due to its arduous requirement such as camera resolution, hardware size, expensive equipment and computational complexity. However, at the present time, technology has overcome these obstacles. Iris recognition can be done through several sequential steps which include pre-processing, features extractions, post-processing, and matching stage. In this paper, we adopted the directional high-low pass filter for feature extraction. A box-counting fractal dimension and Iris code have been proposed as feature representations. Our approach has been tested on CASIA Iris Image database and the results are considered successful.

  8. Iris image recognition wavelet filter-banks based iris feature extraction schemes

    CERN Document Server

    Rahulkar, Amol D

    2014-01-01

    This book provides the new results in wavelet filter banks based feature extraction, and the classifier in the field of iris image recognition. It provides the broad treatment on the design of separable, non-separable wavelets filter banks, and the classifier. The design techniques presented in the book are applied on iris image analysis for person authentication. This book also brings together the three strands of research (wavelets, iris image analysis, and classifier). It compares the performance of the presented techniques with state-of-the-art available schemes. This book contains the compilation of basic material on the design of wavelets that avoids reading many different books. Therefore, it provide an easier path for the new-comers, researchers to master the contents. In addition, the designed filter banks and classifier can also be effectively used than existing filter-banks in many signal processing applications like pattern classification, data-compression, watermarking, denoising etc.  that will...

  9. Iris features-based heart disease diagnosis by computer vision

    Science.gov (United States)

    Nguchu, Benedictor A.; Li, Li

    2017-07-01

    The study takes advantage of several new breakthroughs in computer vision technology to develop a new mid-irisbiomedical platform that processes iris image for early detection of heart-disease. Guaranteeing early detection of heart disease provides a possibility of having non-surgical treatment as suggested by biomedical researchers and associated institutions. However, our observation discovered that, a clinical practicable solution which could be both sensible and specific for early detection is still lacking. Due to this, the rate of majority vulnerable to death is highly increasing. The delayed diagnostic procedures, inefficiency, and complications of available methods are the other reasons for this catastrophe. Therefore, this research proposes the novel IFB (Iris Features Based) method for diagnosis of premature, and early stage heart disease. The method incorporates computer vision and iridology to obtain a robust, non-contact, nonradioactive, and cost-effective diagnostic tool. The method analyzes abnormal inherent weakness in tissues, change in color and patterns, of a specific region of iris that responds to impulses of heart organ as per Bernard Jensen-iris Chart. The changes in iris infer the presence of degenerative abnormalities in heart organ. These changes are precisely detected and analyzed by IFB method that includes, tensor-based-gradient(TBG), multi orientations gabor filters(GF), textural oriented features(TOF), and speed-up robust features(SURF). Kernel and Multi class oriented support vector machines classifiers are used for classifying normal and pathological iris features. Experimental results demonstrated that the proposed method, not only has better diagnostic performance, but also provides an insight for early detection of other diseases.

  10. Optimal Features Subset Selection and Classification for Iris Recognition

    Directory of Open Access Journals (Sweden)

    Prabir Bhattacharya

    2008-06-01

    Full Text Available The selection of the optimal features subset and the classification have become an important issue in the field of iris recognition. We propose a feature selection scheme based on the multiobjectives genetic algorithm (MOGA to improve the recognition accuracy and asymmetrical support vector machine for the classification of iris patterns. We also suggest a segmentation scheme based on the collarette area localization. The deterministic feature sequence is extracted from the iris images using the 1D log-Gabor wavelet technique, and the extracted feature sequence is used to train the support vector machine (SVM. The MOGA is applied to optimize the features sequence and to increase the overall performance based on the matching accuracy of the SVM. The parameters of SVM are optimized to improve the overall generalization performance, and the traditional SVM is modified to an asymmetrical SVM to treat the false accept and false reject cases differently and to handle the unbalanced data of a specific class with respect to the other classes. Our experimental results indicate that the performance of SVM as a classifier is better than the performance of the classifiers based on the feedforward neural network, the k-nearest neighbor, and the Hamming and the Mahalanobis distances. The proposed technique is computationally effective with recognition rates of 99.81% and 96.43% on CASIA and ICE datasets, respectively.

  11. An Offline Fuzzy Based Approach for Iris Recognition with Enhanced Feature Detection

    Science.gov (United States)

    Kodituwakku, S. R.; Fazeen, M. I. M.

    Among many biometric identification methods iris recognition is more attractive due to the unique features of the human eye [1]. There are many proposed algorithms for iris recognition. Although all these methods are based on the properties of the iris, they are subject to some limitations. In this research we attempt to develop an algorithm for iris recognition based on Fuzzy logic incorporated with not only the visible properties of the human iris but also considering the iris function. Visible features of the human iris such as pigment related features, features controlling the size of the pupil, visible rare anomalies, pigment frill and Collarette are considered [2]. This paper presents the algorithm we developed to recognize iris. A prototype system developed is also discussed.

  12. Iris image enhancement for feature recognition and extraction

    CSIR Research Space (South Africa)

    Mabuza, GP

    2012-10-01

    Full Text Available domain by using three enhancement techniques namely: (i) local histogram equalisation, (ii) global histogram equalisation and (iii) partial contrast, to improve the quality of iris images from three different iris databases....

  13. Measuring Biometric Sample Quality in terms of Biometric Feature Information in Iris Images

    Directory of Open Access Journals (Sweden)

    R. Youmaran

    2012-01-01

    Full Text Available This paper develops an approach to measure the information content in a biometric feature representation of iris images. In this context, the biometric feature information is calculated using the relative entropy between the intraclass and interclass feature distributions. The collected data is regularized using a Gaussian model of the feature covariances in order to practically measure the biometric information with limited data samples. An example of this method is shown for iris templates processed using Principal-Component Analysis- (PCA- and Independent-Component Analysis- (ICA- based feature decomposition schemes. From this, the biometric feature information is calculated to be approximately 278 bits for PCA and 288 bits for ICA iris features using Masek's iris recognition scheme. This value approximately matches previous estimates of iris information content.

  14. IRIS

    African Journals Online (AJOL)

    Esem

    their HIV status as they are asymptomatic in the. 1 early neonatal period . The vaccine coverage rate for. 2. BCG currently stands at 95% . Observational case series of Immune Reconstitution. Inflammatory Syndrome (IRIS) following initiation of. Antiretroviral Therapy in infants with absent BCG scars in Lusaka, Zambia. 1. 1.

  15. Measuring Biometric Sample Quality in terms of Biometric Feature Information in Iris Images

    OpenAIRE

    Youmaran, R.; Adler, A.

    2012-01-01

    This paper develops an approach to measure the information content in a biometric feature representation of iris images. In this context, the biometric feature information is calculated using the relative entropy between the intraclass and interclass feature distributions. The collected data is regularized using a Gaussian model of the feature covariances in order to practically measure the biometric information with limited data samples. An example of this method is shown for iris templates ...

  16. Iris feature based watermarking algorithm for personal identification

    Science.gov (United States)

    Feng, Gui; Lin, Qiwei

    2007-11-01

    Rapidly development of technique causes big problem on the security of digital product. The digital signature technique and watermarking technique are common used solution, but hidden security trouble is still existed. A new biometric watermarking scheme is proposed for property protecting and digital product owner identification. The scheme adopts the iris of digital product holder as watermark, which has the advantage of uniqueness, stability and impossible been counterfeited, so the security level is improved. In this scheme, we utilize person's iris to generate the watermark, and embed this watermark signal into the host image like certification of consumer or other document. While identifying or verifying the owner of the product, we first extract and reconstruct the watermark, then compare the watermark (i.e. the iris image) with the field collected iris image to verify authority. Because there is a direct relationship between the certification holder and the credentials; the reliability is improved greatly.

  17. FAST DISCRETE CURVELET TRANSFORM BASED ANISOTROPIC FEATURE EXTRACTION FOR IRIS RECOGNITION

    Directory of Open Access Journals (Sweden)

    Amol D. Rahulkar

    2010-11-01

    Full Text Available The feature extraction plays a very important role in iris recognition. Recent researches on multiscale analysis provide good opportunity to extract more accurate information for iris recognition. In this work, a new directional iris texture features based on 2-D Fast Discrete Curvelet Transform (FDCT is proposed. The proposed approach divides the normalized iris image into six sub-images and the curvelet transform is applied independently on each sub-image. The anisotropic feature vector for each sub-image is derived using the directional energies of the curvelet coefficients. These six feature vectors are combined to create the resultant feature vector. During recognition, the nearest neighbor classifier based on Euclidean distance has been used for authentication. The effectiveness of the proposed approach has been tested on two different databases namely UBIRIS and MMU1. Experimental results show the superiority of the proposed approach.

  18. A Narrative Methodology to Recognize Iris Patterns By Extracting Features Using Gabor Filters and Wavelets

    Directory of Open Access Journals (Sweden)

    Shristi Jha

    2016-01-01

    Full Text Available Iris pattern Recognition is an automated method of biometric identification that uses mathematical pattern-Recognition techniques on images of one or both of the irises of an individual’s eyes, whose complex random patterns are unique, stable, and can be seen from some distance. Iris recognition uses video camera technology with subtle near infrared illumination to acquire images of the detail-rich, intricate structures of the iris which are visible externally. In this narrative research paper the input image is captured and the success of the iris recognition depends on the quality of the image so the captured image is subjected to the preliminary image preprocessing techniques like localization, segmentation, normalization and noise detection followed by texture and edge feature extraction by using Gabor filters and wavelets then the processed image is matched with templates stored in the database to detect the Iris Patterns.

  19. Developing virtual REU cohorts: Reflections from the IRIS Undergraduate Internship Program

    Science.gov (United States)

    Hubenthal, M.; Taber, J.; Aster, R.; Frassetto, A.

    2007-12-01

    Beginning in 2006, the IRIS Education and Outreach program received funding from the National Science Foundation (EAR-0453427) to explore a novel approach to the traditional Research Experience for Undergraduates (REU) model. This model blends the spirit of an REU program, which traditionally hosts participants in one location with successful prior IRIS experience hosting students at widely separated institutions to participate in summer research. A unique feature the IRIS Undergraduate Internship Program is that throughout the summer, interns form and sustain a virtual community, offering assistance, sharing ideas, asking questions, and relaying life experiences while conducting their research at diverse institutions. Key to IRIS's REU model is a combination of: one-on-one mentoring by researchers at IRIS institutions across the US, developing a strong unity among interns through both face-to-face and on-line interactions, participation of an IRIS REU alumni mentor to provide both group and intern-specific guidance developing interns' abilities to self-evaluate and work independently, through carefully designed web-based tools, and increasing interns' awareness of the IRIS and broader Earth Science community; demonstrating the role they will play in this larger community. Virtual interaction is facilitated by 1) bringing students together for face-to-face contact, through a week long orientation held annually at the IRIS PASSCAL Instrument Center on the campus of the New Mexico Institute of Mining and Technology, and 2) the community enabling web infrastructure at http://www.iris.edu/internship/. During the orientation students engage in classes in geophysics basics, career preparation, as well as training to communicate virtually. Our experiences and evaluations from the 2006 and 2007 field seasons have:shown the increasing demand for electronic advertising of REU programs, provided support for several assumptions of the model including the key role of both the

  20. Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition

    Directory of Open Access Journals (Sweden)

    Md. Rabiul Islam

    2014-01-01

    Full Text Available The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  1. The Iris biometric feature segmentation using finite element method

    Directory of Open Access Journals (Sweden)

    David Ibitayo LANLEGE

    2015-05-01

    Full Text Available This manuscript presents a method for segmentation of iris images based on a deformable contour (active contour paradigm. The deformable contour is a novel approach in image segmentation. A type of active contour is the Snake. Snake is a parametric curve defined within the domain of the image. Snake properties are specified through a function called energy functional. This means they consist of packets of energy which expressed as partial Differential Equations. The partial Differential Equation is the controlling engine of the active contour since this project, the Finite Element Method (Standard Galerkin Method implementation for deformable model is presented.

  2. An iris localization algorithm based on geometrical features of cow eyes

    Science.gov (United States)

    Zhang, Menglu; Zhao, Lindu; Kong, Qiang

    2009-10-01

    Abrupt vicious affairs on meat food safety show rapid expansion, which poses a threat to food safety and human health. In order to trace the flow of meat products in the food supply chain, the research on the individual identification of large animals based on iris recognition has very important practical significance. Iris localization is the key step in the iris recognition system, and this paper makes the cow iris as an example to propose two-step localization method on the basis of studying and analyzing lots of cow geometrical features. Firstly, threshold transform and Sobel edge detection operator are used to make the image binarization processing and realize coarse location, and the coordinates of boundary points are determined with the quadratic B-spline interpolation curves. Secondly, the cow eye iris image is located from the coarseness to fine through fitting circles. This paper proposes two methods to determine the parameters of the inner and outer boundary circles, including fitting concentric and non-concentric circle. Experimental results show that fitting non-concentric circle algorithm can locate iris region quickly and efficiently and has better accuracy and good robustness.

  3. Face-iris multimodal biometric scheme based on feature level fusion

    Science.gov (United States)

    Huo, Guang; Liu, Yuanning; Zhu, Xiaodong; Dong, Hongxing; He, Fei

    2015-11-01

    Unlike score level fusion, feature level fusion demands all the features extracted from unimodal traits with high distinguishability, as well as homogeneity and compatibility, which is difficult to achieve. Therefore, most multimodal biometric research focuses on score level fusion, whereas few investigate feature level fusion. We propose a face-iris recognition method based on feature level fusion. We build a special two-dimensional-Gabor filter bank to extract local texture features from face and iris images, and then transform them by histogram statistics into an energy-orientation variance histogram feature with lower dimensions and higher distinguishability. Finally, through a fusion-recognition strategy based on principal components analysis and support vector machine (FRSPS), feature level fusion and one-to-n identification are accomplished. The experimental results demonstrate that this method can not only effectively extract face and iris features but also provide higher recognition accuracy. Compared with some state-of-the-art fusion methods, the proposed method has a significant performance advantage.

  4. 77 FR 26751 - Integrated Risk Information System (IRIS); Announcement of 2012 Program

    Science.gov (United States)

    2012-05-07

    ... chemicals are withdrawn from the IRIS agenda: Chemical Cas No. alkylates various. bisphenol A 80-05-7. mirex... are nominated in the future, the IRIS Program will consider these nominations individually. Bisphenol A is withdrawn because EPA is awaiting further analysis and results from the U.S. Food and Drug...

  5. Leveraging community support for Education and Outreach: The IRIS E&O Program

    Science.gov (United States)

    Taber, J.; Hubenthal, M.; Wysession, M. E.

    2009-12-01

    The IRIS E&O Program was initiated 10 years ago, some 15 years after the creation of the IRIS Consortium, as IRIS members increasingly recognized the fundamental need to communicate the results of scientific research more effectively and to attract more students to study Earth science. Since then, IRIS E&O has received core funding through successive 5-year cooperative agreements with NSF, based on proposals submitted by IRIS. While a small fraction of the overall Consortium budget, this consistent funding has allowed the development of strong, long-term elements within the E&O Program, including summer internships, IRIS/USGS museum displays, seismographs in schools, IRIS/SSA Distinguished Lecture series, and professional development for middle school and high school teachers. Reliable funding has allowed us to develop expertise in these areas due to the longevity of the programs and the continuous improvement resulting from ongoing evaluations. Support from Consortium members, including volunteering time and expertise, has been critical for the program, as the Consortium has to continually balance the value of E&O products versus equipment and data services for seismology research. The E&O program also provides service to the Consortium, such as PIs being able to count on and leverage IRIS resources when defining the broader impacts of their own research. The reliable base has made it possible to build on the core elements with focused and innovative proposals, allowing, for example, the expansion of our internship program into a full REU site. Developing collaborative proposals with other groups has been a key strategy where IRIS E&O's long-term viability can be combined with expertise from other organizations to develop new products and services. IRIS can offer to continue to reliably deliver and maintain products after the end of a 2-3 year funding cycle, which can greatly increase the reach of the project. Consortium backing has also allowed us to establish an

  6. The IRIS Education and Outreach Program: Providing access to data and equipment for educational and public use

    Science.gov (United States)

    Taber, J.; Toigo, M.; Bravo, T. K.; Hubenthal, M.; McQuillan, P. J.; Welti, R.

    2009-12-01

    The IRIS Education and Outreach Program has been an integral part of IRIS for the past 10 years and during that time has worked to advance awareness and understanding of seismology and earth science while inspiring careers in geophysics. The focus on seismology and the use of seismic data has allowed the IRIS E&O program to develop and disseminate a unique suite of products and services for a wide range of audiences. One result of that effort has been increased access to the IRIS Data Management System by non-specialist audiences and simplified use of location and waveform data. The Seismic Monitor was one of the first Web-based tools for observing near-real-time seismicity. It continues to be the most popular IRIS web page, and thus it presents aspects of seismology to a very wide audience. For individuals interested in more detailed ground motion information, waveforms can be easily viewed using the Rapid Earthquake Viewer, developed by the University of South Carolina in collaboration with IRIS E&O. The Seismographs in Schools program gives schools the opportunity to apply for a low-cost educational seismograph and to receive training for its use in the classroom. To provide better service to the community, a new Seismographs in Schools website was developed in the past year with enhanced functions to help teachers improve their teaching of seismology. The site encourages schools to make use of seismic data and communicate with other educational seismology users throughout the world. Users can view near-real-time displays of other participating schools, upload and download data, and use the “find a teacher” tool to contact nearby schools that also may be operating seismographs. In order to promote and maintain program participation and communication, the site features a discussion forum to encourage and support the growing global community of educational seismograph users. Any data that is submitted to the Seismographs in Schools Website is also accessible

  7. The Promotion of the use of Seismic Data via the IRIS Education and Outreach Program

    Science.gov (United States)

    Taber, J.; Aster, R. C.; Braile, L. W.; Hall-Wallace, M.

    2002-12-01

    The Incorporated Research Institutions for Seismology (IRIS) recognizes the potential for coordinated Education and Outreach activities in seismology to contribute significantly to the advancement of national awareness, interest, and understanding of science and mathematics. IRIS E&O activities are targeted at audiences ranging from K-16 students to the general public, and are focused on areas where IRIS is well-positioned to make substantive contributions stemming from its strong research and data resources. Program goals are advanced by the E&O staff in close collaboration with diverse allies, including IRIS members, K-12 teachers, undergraduate institutions, the media, and science museums. IRIS also works closely with other national and regional Earth science organizations to maximize effectiveness and reduce redundancy. Leveraging IRIS resources to produce nationally significant results requires substantial and sustained outreach to the wider education community. Important efforts in this direction include a range of K-16 teacher workshops, a new Educational Affiliate membership for undergraduate institutions, and widely distributed teaching modules and associated tools. Students can access global seismic data from the IRIS Data Management System in near real time as well as by selecting events from the online archives. Earthquake locations and information are available via a new interactive map (the Seismic Monitor). Students can also collect their own seismic data using a stand-alone, relatively inexpensive seismograph (the AS1), or with research-quality broadband instruments with continuous network connections. Consortium members are currently developing new visualization tools and classroom activities using seismic data. Outreach to the general public includes a distinguished lecture program, museum exhibits with real-time displays of earthquake locations and ground motion, access to and use of seismic data via our website, and other informational materials.

  8. Toward More Accurate Iris Recognition Using Cross-Spectral Matching.

    Science.gov (United States)

    Nalla, Pattabhi Ramaiah; Kumar, Ajay

    2017-01-01

    Iris recognition systems are increasingly deployed for large-scale applications such as national ID programs, which continue to acquire millions of iris images to establish identity among billions. However, with the availability of variety of iris sensors that are deployed for the iris imaging under different illumination/environment, significant performance degradation is expected while matching such iris images acquired under two different domains (either sensor-specific or wavelength-specific). This paper develops a domain adaptation framework to address this problem and introduces a new algorithm using Markov random fields model to significantly improve cross-domain iris recognition. The proposed domain adaptation framework based on the naive Bayes nearest neighbor classification uses a real-valued feature representation, which is capable of learning domain knowledge. Our approach to estimate corresponding visible iris patterns from the synthesis of iris patches in the near infrared iris images achieves outperforming results for the cross-spectral iris recognition. In this paper, a new class of bi-spectral iris recognition system that can simultaneously acquire visible and near infra-red images with pixel-to-pixel correspondences is proposed and evaluated. This paper presents experimental results from three publicly available databases; PolyU cross-spectral iris image database, IIITD CLI and UND database, and achieve outperforming results for the cross-sensor and cross-spectral iris matching.

  9. Score level fusion scheme based on adaptive local Gabor features for face-iris-fingerprint multimodal biometric

    Science.gov (United States)

    He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Chen, Ying

    2014-05-01

    A multimodal biometric system has been considered a promising technique to overcome the defects of unimodal biometric systems. We have introduced a fusion scheme to gain a better understanding and fusion method for a face-iris-fingerprint multimodal biometric system. In our case, we use particle swarm optimization to train a set of adaptive Gabor filters in order to achieve the proper Gabor basic functions for each modality. For a closer analysis of texture information, two different local Gabor features for each modality are produced by the corresponding Gabor coefficients. Next, all matching scores of the two Gabor features for each modality are projected to a single-scalar score via a trained, supported, vector regression model for a final decision. A large-scale dataset is formed to validate the proposed scheme using the Facial Recognition Technology database-fafb and CASIA-V3-Interval together with FVC2004-DB2a datasets. The experimental results demonstrate that as well as achieving further powerful local Gabor features of multimodalities and obtaining better recognition performance by their fusion strategy, our architecture also outperforms some state-of-the-art individual methods and other fusion approaches for face-iris-fingerprint multimodal biometric systems.

  10. Iris Recognition Using Wavelet

    Directory of Open Access Journals (Sweden)

    Khaliq Masood

    2013-08-01

    Full Text Available Biometric systems are getting more attention in the present era. Iris recognition is one of the most secure and authentic among the other biometrics and this field demands more authentic, reliable and fast algorithms to implement these biometric systems in real time. In this paper, an efficient localization technique is presented to identify pupil and iris boundaries using histogram of the iris image. Two small portions of iris have been used for polar transformation to reduce computational time and to increase the efficiency of the system. Wavelet transform is used for feature vector generation. Rotation of iris is compensated without shifts in the iris code. System is tested on Multimedia University Iris Database and results show that proposed system has encouraging performance.

  11. Iris Recognition for Human Identification

    Science.gov (United States)

    Alandkar, Lajari; Gengaje, Sachin

    2010-11-01

    Iris recognition system is the biometric identification system. Iris has an intricate structure, uniqueness, stability, and natural protection. Due to these features of the iris it can be used for biometric identification. This system gives better performance than other biometric identification systems. A novel eyelash removal method for preprocessing of human iris images in a human iris recognition system is presented.. Discrete cosine transform (DCT) method is used for feature extraction. For matching of two-iris code Hamming distance calculation is used. EER value must be less for the optimum performance of the system.

  12. Using crypts as iris minutiae

    Science.gov (United States)

    Shen, Feng; Flynn, Patrick J.

    2013-05-01

    Iris recognition is one of the most reliable biometric technologies for identity recognition and verification, but it has not been used in a forensic context because the representation and matching of iris features are not straightforward for traditional iris recognition techniques. In this paper we concentrate on the iris crypt as a visible feature used to represent the characteristics of irises in a similar way to fingerprint minutiae. The matching of crypts is based on their appearances and locations. The number of matching crypt pairs found between two irises can be used for identity verification and the convenience of manual inspection makes iris crypts a potential candidate for forensic applications.

  13. Simplified safety and containment systems for the iris reactor

    Energy Technology Data Exchange (ETDEWEB)

    Conway, L.E. [Westinghouse Electric Co., Pittsburgh, PA (United States); Lombardi, C.; Ricotti, M.; Oriani, L. [Polytechnic of Milan, Dept. of Nuclear Engineering, Milan (Italy)

    2001-07-01

    The IRIS (International Reactor Innovative and Secure) is a 100 - 300 MW modular type pressurized water reactor supported by the U.S. DOE NERI Program. IRIS features a long-life core to provide proliferation resistance and to reduce the volume of spent fuel, as well as reduce maintenance requirements. IRIS utilizes an integral reactor vessel that contains all major primary system components. This integral reactor vessel makes it possible to reduce containment size; making the IRIS more cost competitive. IRIS is being designed to enhance reactor safety, and therefore a key aspect of the IRIS program is the development of the safety and containment systems. These systems are being designed to maximize containment integrity, prevent core uncover following postulated accidents, minimize the probability and consequences of severe accidents, and provide a significant simplification over current safety system designs. The design of the IRIS containment and safety systems has been identified and preliminary analyses have been completed. The IRIS safety concept employs some unique features that minimize the consequences of postulated design basis events. This paper will provide a description of the containment design and safety systems, and will summarize the analysis results. (author)

  14. Perancangan Program Aplikasi Deteksi Iris Mata untuk Absensi Karyawan Menggunakan Metode Gabor Wavelet

    Directory of Open Access Journals (Sweden)

    Zahedi Zahedi

    2011-06-01

    Full Text Available To take the employees’ absences in a company, a variety of invented tools or technologies are and already used, for example, attendance cards, fingerprints attendance tool, and attendance tool that uses facial recognition. Attendance tool with a facial recognition uses iris recognition of those employees. Iris code has many properties that hard to forge. Thus, the detection and iris recognition is one of the most secure and accurate for identification. 

  15. Iris colour as an indicator of age feature in female Brazilian tanagers (Passeriformes: Emberizidae confirmed by a molecular sexing technique

    Directory of Open Access Journals (Sweden)

    Denise Monnerat Nogueira

    2008-12-01

    Full Text Available The Brazilian tanager, Ramphocelus bresilius is an endemic species from Brazil that is sexually dimorphic in adult plumage. Young males are similar to adult and young females until their second year. Adults and young females are not distinguishable in plumage. We tested whether iris colour can be used to separate adult females from immature females. We used for the first time the molecular sexing technique based on CHD-genes to confirm the sex of the individuals classified as "female plumage with red iris", and to identify the sex of individuals classified as "female plumage and brown iris". The adult males were used as a positive control. DNA samples from 190 individuals were analysed. The sizes of the PCR products were identified as 350 base pairs (bp for CHD-Z and 388 bp for CHD-W. We confirmed that adult females have a red iris and the young females a brown iris. We could also separate young males and females which present the same iris colour and plumage. Although there are indications that the iris colour can be used by birds to identify the adults in co-operative breeding species such as the Brazilian tanager, more behavioural data are required to understand the role of iris coloration in this species. Rev. Biol. Trop. 56 (4: 1629-1633. Epub 2008 December 12.El ave Ramphocelus bresilius es una especie endémica de Brasil con dimorfismo sexual en el plumaje del adulto. Los machos jóvenes son similares a las hembras adultas y jóvenes hasta el segundo año de vida. Adultos y hembras jóvenes son indistinguibles por el plumaje. Evaluamos si el color del iris puede ser utilizado para distinguir hembras adultas de hembras inmaduras. Utilizamos por primera vez la técnica molecular de identificación de sexos basada en los genes CHD para confirmar el género de individuos clasificados como plumaje femenino con iris rojo, y para identificar el sexo de los individuos clasificados como plumaje femenino e iris marrón. Usamos machos adultos como

  16. Fingerprint + Iris = IrisPrint

    Science.gov (United States)

    Othman, Asem; Ross, Arun

    2015-05-01

    We consider the problem of generating a biometric image from two different traits. Specifically, we focus on generating an IrisPrint that inherits its structure from a fingerprint image and an iris image. To facilitate this, the continuous phase of the fingerprint image, characterizing its ridge flow, is first extracted. Next, a scheme is developed to extract "minutiae" from an iris image. Finally, an IrisPrint, that resembles a fingerprint, is created by mixing the ridge flow of the fingerprint with the iris minutiae. Preliminary experiments suggest that the new biometric image (i.e., IrisPrint) (a) can potentially be used for authentication by an existing fingerprint matcher, and (b) can potentially conceal and preserve the privacy of the original fingerprint and iris images.

  17. Privacy Preserving Iris Based Biometric Identity Verification

    Directory of Open Access Journals (Sweden)

    Przemyslaw Strzelczyk

    2011-08-01

    Full Text Available Iris biometrics is considered one of the most accurate and robust methods of identity verification. Individually unique iris features can be presented in a compact binary form easily compared with reference template to confirm identity. However, when templates or features are disclosed, iris biometrics is no longer suitable for verification. Therefore, there is a need to perform iris feature matching without revealing the features itself and reference template. The paper proposes an extension of the standard iris-based verification protocol that introduces features and a template locking mechanism, which guarantees that no sensitive information is exposed.Article in English

  18. Exploiting iris dynamics

    Science.gov (United States)

    Hsu, Charles; Szu, Harold

    2010-04-01

    The human iris is a circular curtain over the light entrance pupil which is controlled directly by the intensity of blue light from photosensitive ganglions in the retina within the eye. The human iris dynamic is remarkable in that it is capable of shrinking concentrically along the radial direction by a factor 4 from 8mm to 2mm, and constantly oscillates in 1/2 second periodicity. Pupil dilation and contraction causes the iris texture to undergo nonlinear deformation with discrete components and minutia features. Thus, iris recognition must be scale invariant due to the pupil dynamics. We propose the Mandelbrot fractal dimension count of minutia iris details, at different intensity thresholds, in dilation-invariant wedge-boxes, formed at specific angular sizes, but spatially varying over 4 90° quadrants due to the cellular growth under the gravity. Despite the concentric dynamic, we have sought an invariant fractal dimensionality in the circular direction and discovered the non-isotropic effect, departed from the simple Richardson fractal law. Furthermore, we choose an optimum Rayleigh criterion λ/D matching the robust fine resolution scale for the given lens aperture D and the illumination wavelength λ for a potential application from a distant, with the help of comprehensive biometric including iris.

  19. Effective Preparation Program Features: A Literature Review

    Science.gov (United States)

    Crow, Gary M.; Whiteman, Rodney S.

    2016-01-01

    This article is a summary of a report prepared for the University Council for Educational Administration Program Improvement Project for the Wallace Foundation. This explores the research base for educational leadership preparation programs, specifically examining literature on program features. The review covers context, candidates, faculty,…

  20. Remodularizing Java programs for comprehension of features

    DEFF Research Database (Denmark)

    Olszak, Andrzej; Jørgensen, Bo Nørregaard

    2009-01-01

    . In absence of these mechanisms, feature implementations tend to be scattered and tangled in terms of object-oriented abstractions, making the code implementing features difficult to locate and comprehend. In this paper we present a semi-automatic method for feature-oriented remodularization of Java programs....... Our method uses execution traces to locate implementations of features, and Java packages to establish explicit feature modules. To evaluate usefulness of the approach, we present a case study where we apply our method to two real-world software systems. The obtained results indicate a significant...

  1. A new approach for cancelable iris recognition

    Science.gov (United States)

    Yang, Kai; Sui, Yan; Zhou, Zhi; Du, Yingzi; Zou, Xukai

    2010-04-01

    The iris is a stable and reliable biometric for positive human identification. However, the traditional iris recognition scheme raises several privacy concerns. One's iris pattern is permanently bound with him and cannot be changed. Hence, once it is stolen, this biometric is lost forever as well as all the applications where this biometric is used. Thus, new methods are desirable to secure the original pattern and ensure its revocability and alternatives when compromised. In this paper, we propose a novel scheme which incorporates iris features, non-invertible transformation and data encryption to achieve "cancelability" and at the same time increases iris recognition accuracy.

  2. Academy Distance Learning Tools (IRIS) -

    Data.gov (United States)

    Department of Transportation — IRIS is a suite of front-end web applications utilizing a centralized back-end Oracle database. The system fully supports the FAA Academy's Distance Learning Program...

  3. IRIS TECHNOLOGY: A REVIEW ON IRIS BASED BIOMETRIC SYSTEMS FOR UNIQUE HUMAN IDENTIFICATION

    OpenAIRE

    Dr M V Bramhananda Reddy; Dr V Goutham

    2018-01-01

    Biometric features are widely used in real time applications for unique human identification. Iris is one of the physiological biometric features which are regarded as highly reliable in biometric identification systems. Often iris is combined with other biometric features for robust biometric systems. It is also observed that biometrics is combined with cryptography for stronger security mechanisms. Since iris is unique for all individuals across the globe, many researchers focused on using ...

  4. A fourier transform quality measure for iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2014-08-01

    Full Text Available Iris recognition systems have attracted much attention for their uniqueness, stability and reliability. However, performance of this system depends on quality of acquired iris sample. This is because in order to obtain reliable features good quality...

  5. Enhanced iris recognition method based on multi-unit iris images

    Science.gov (United States)

    Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung

    2013-04-01

    For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the

  6. Iris Recognition: The Consequences of Image Compression

    Directory of Open Access Journals (Sweden)

    Craig Belcher

    2010-01-01

    Full Text Available Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  7. Upper atmospheric effects of the hf active auroral research program ionospheric research instrument (HAARP IRI)

    Energy Technology Data Exchange (ETDEWEB)

    Eccles, V.; Armstrong, R.

    1993-05-01

    The earth's ozone layer occurs in the stratosphere, primarily between 10 and 30 miles altitude. The amount of ozone, O3, present is the result of a balance between production and destruction processes. Experiments have shown that natural processes such as auroras create molecules that destroy O. One family of such molecules is called odd nitrogen of which nitric oxide (NO) is an example. Because the HAARP (HF Active Auroral Research Program) facility is designed to mimic and investigate certain natural processes, a study of possible effects of HAARP on the ozone layer was conducted. The study used a detailed model of the thermal and chemical effects of the high power HF beam, which interacts with free electrons in the upper atmosphere above 50 miles altitude. It was found only a small fraction of the beam energy goes into the production of odd nitrogen molecules, whereas odd nitrogen is efficiently produced by auroras. Since the total energy emitted by HAARP in the year is some 200,000 times less than the energy deposited in the upper atmosphere by auroras, the study demonstrates that HAARP HF beam experiments will cause no measurable depletion of the earth's ozone layer.... Ozone, Ozone depletion, Ozone layer, Odd nitrogen, Nitric oxide, HAARP Emitter characteristics.

  8. Efficient Iris Localization via Optimization Model

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2017-01-01

    Full Text Available Iris localization is one of the most important processes in iris recognition. Because of different kinds of noises in iris image, the localization result may be wrong. Besides this, localization process is time-consuming. To solve these problems, this paper develops an efficient iris localization algorithm via optimization model. Firstly, the localization problem is modeled by an optimization model. Then SIFT feature is selected to represent the characteristic information of iris outer boundary and eyelid for localization. And SDM (Supervised Descent Method algorithm is employed to solve the final points of outer boundary and eyelids. Finally, IRLS (Iterative Reweighted Least-Square is used to obtain the parameters of outer boundary and upper and lower eyelids. Experimental result indicates that the proposed algorithm is efficient and effective.

  9. IRIS Final Technical Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    M. D. Carelli

    2003-11-03

    OAK-B135 This NERI project, originally started as the Secure Transportable Autonomous Light Water Reactor (STAR-LW) and currently known as the International Reactor Innovative and Secure (IRIS) project, had the objective of investigating a novel type of water-cooled reactor to satisfy the Generation IV goals: fuel cycle sustainability, enhanced reliability and safety, and improved economics. The research objectives over the three-year (1999-2002) program were as follows: First year: Assess various design alternatives and establish main characteristics of a point design; Second year: Perform feasibility and engineering assessment of the selected design solutions; Third year: Complete reactor design and performance evaluation, including cost assessment These objectives were fully attained and actually they served to launch IRIS as a full fledged project for eventual commercial deployment. The program did not terminate in 2002 at the end of the NERI program, and has just entered in its fifth year. This has been made possible by the IRIS project participants which have grown from the original four member, two-countries team to the current twenty members, nine countries consortium. All the consortium members work under their own funding and it is estimated that the value of their in-kind contributions over the life of the project has been of the order of $30M. Currently, approximately 100 people worldwide are involved in the project. A very important constituency of the IRIS project is the academia: 7 universities from four countries are members of the consortium and five more US universities are associated via parallel NERI programs. To date, 97 students have worked or are working on IRIS; 59 IRIS-related graduate theses have been prepared or are in preparation, and 41 of these students have already graduated with M.S. (33) or Ph.D. (8) degrees. This ''final'' report (final only as far as the NERI program is concerned) summarizes the work performed

  10. SURVEY OF BIOMETRIC SYSTEMS USING IRIS RECOGNITION

    OpenAIRE

    S.PON SANGEETHA; Dr. M. Karnan

    2014-01-01

    The security plays an important role in any type of organization in today’s life. Iris recognition is one of the leading automatic biometric systems in the area of security which is used to identify the individual person. Biometric systems include fingerprints, facial features, voice recognition, hand geometry, handwriting, the eye retina and the most secured one presented in this paper, the iris recognition. Biometric systems has become very famous in security systems because it is not possi...

  11. IRIS Toxicological Review of Dichloromethane (Methylene ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site

  12. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  13. TAPIOCA MELANOMA OF THE IRIS

    NARCIS (Netherlands)

    DEKEIZER, RJW; OOSTERHUIS, JA; HOUTMAN, WA; DEWOLFFROUENDAAL, D

    Clinical identification of tapioca melanoma of the iris is important because its medical treatment may differ from that of other malignant iris melanomas. The characteristic iris nodules must be differentiated from granulomatous uveitis, metastases, and Lisch nodules (neurofibromatosis). We will

  14. Iris and periocular biometrics

    CERN Document Server

    Rathgeb, Christian

    2017-01-01

    This book provides an overview of scientific fundamentals and principles of iris and periocular biometric recognition. It covers: an introduction to iris and periocular recognition; a selective overview of issues and challenges; soft biometric classification; security aspects; privacy protection and forensics; and future trends.

  15. Scale Invariant Gabor Descriptor-based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Zhi Zhou

    2010-01-01

    Full Text Available A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  16. Scale Invariant Gabor Descriptor-Based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Du Yingzi

    2010-01-01

    Full Text Available Abstract A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  17. Multimodal Algorithm for Iris Recognition with Local Topological Descriptors

    Science.gov (United States)

    Campos, Sergio; Salas, Rodrigo; Allende, Hector; Castro, Carlos

    This work presents a new method for feature extraction of iris images to improve the identification process. The valuable information of the iris is intrinsically located in its natural texture, and preserving and extracting the most relevant features is of paramount importance. The technique consists in several steps from adquisition up to the person identification. Our contribution consists in a multimodal algorithm where a fragmentation of the normalized iris image is performed and, afterwards, regional statistical descriptors with Self-Organizing-Maps are extracted. By means of a biometric fusion of the resulting descriptors, the features of the iris are compared and classified. The results with the iris data set obtained from the Bath University repository show an excellent accuracy reaching up to 99.867%.

  18. Iris Freckles a Potential Biomarker for Chronic Sun Damage.

    Science.gov (United States)

    Schwab, Christoph; Mayer, Christoph; Zalaudek, Iris; Riedl, Regina; Richtig, Markus; Wackernagel, Werner; Hofmann-Wellenhof, Rainer; Richtig, Georg; Langmann, Gerald; Tarmann, Lisa; Wedrich, Andreas; Richtig, Erika

    2017-05-01

    To investigate the role of sunlight exposure in iris freckles formation. We prospectively examined volunteers attending a skin cancer screening program conducted by ophthalmologists and dermatologists. Frequency and topographical variability of iris freckles were noted and associated with behavioral and dermatologic characteristics indicating high sun exposure. Six hundred thirty-two participants (n = 360; 57% female) were examined. Mean age of all participants was 38.4 ± 18.4 years (range, 4-84 years). Of all individuals, 76.1% (n = 481) exhibited at least one iris freckle. Most freckles were observed in the inferior temporal quadrant. The presence of iris freckles was associated with higher age (participants with iris freckles: 41.8 ± 16.8 years versus participants without iris freckles: 27.6 ± 19.2 years), a high number of sunburns during lifetime (>10: 31% vs. 19%), sunlight-damaged skin (26% vs. 11%), presence of actinic lentigines (72% vs. 45%), and a high total nevus body count (>10; 78% vs. 67%). The association of iris freckles, behavioral factors, and dermatologic findings, as well as the topographical distribution, indicate that sunlight exposure may trigger the formation of iris freckles. The evaluation of iris freckles offers an easily accessible potential biomarker, which might be helpful in indicating sun damage on the skin associated with cutaneous malignancies. Furthermore, the evaluation of iris freckles could also be helpful in understanding the role of sunlight in several ophthalmologic diseases.

  19. Feature extraction from multiple data sources using genetic programming.

    Energy Technology Data Exchange (ETDEWEB)

    Szymanski, J. J. (John J.); Brumby, Steven P.; Pope, P. A. (Paul A.); Eads, D. R. (Damian R.); Galassi, M. C. (Mark C.); Harvey, N. R. (Neal R.); Perkins, S. J. (Simon J.); Porter, R. B. (Reid B.); Theiler, J. P. (James P.); Young, A. C. (Aaron Cody); Bloch, J. J. (Jeffrey J.); David, N. A. (Nancy A.); Esch-Mosher, D. M. (Diana M.)

    2002-01-01

    Feature extration from imagery is an important and long-standing problem in remote sensing. In this paper, we report on work using genetic programming to perform feature extraction simultaneously from multispectral and digital elevation model (DEM) data. The tool used is the GENetic Imagery Exploitation (GENIE) software, which produces image-processing software that inherently combines spatial and spectral processing. GENIE is particularly useful in exploratory studies of imagery, such as one often does in combining data from multiple sources. The user trains the software by painting the feature of interest with a simple graphical user interface. GENIE then uses genetic programming techniques to produce an image-processing pipeline. Here, we demonstrate evolution of image processing algorithms that extract a range of land-cover features including towns, grasslands, wild fire burn scars, and several types of forest. We use imagery from the DOE/NNSA Multispectral Thermal Imager (MTI) spacecraft, fused with USGS 1:24000 scale DEM data.

  20. Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study.

    Science.gov (United States)

    Diniz Filho, Alberto; Cronemberger, Sebastião; Ferreira, Dollores Martins; Mérula, Rafael Vidal; Calixto, Nassim

    2010-01-01

    To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration) or partially absent (incomplete plateau iris configuration) ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 microm from the scleral spur; peripheral iris thickness at 500 microm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. Plateau iris configuration was found in 33 eyes of 20 (10.2%) out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3%) out of 32 patients with acute primary angleclosure. Seventeen (77.3%) patients with plateau iris configuration were female and 5 (22.7%) male. Twenty-three (62.2%) out of 37 eyes had complete plateau iris configuration, and 14 (37.8%) had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration presented similar biometric

  1. Feature Scaling via Second-Order Cone Programming

    Directory of Open Access Journals (Sweden)

    Zhizheng Liang

    2016-01-01

    Full Text Available Feature scaling has attracted considerable attention during the past several decades because of its important role in feature selection. In this paper, a novel algorithm for learning scaling factors of features is proposed. It first assigns a nonnegative scaling factor to each feature of data and then adopts a generalized performance measure to learn the optimal scaling factors. It is of interest to note that the proposed model can be transformed into a convex optimization problem: second-order cone programming (SOCP. Thus the scaling factors of features in our method are globally optimal in some sense. Several experiments on simulated data, UCI data sets, and the gene data set are conducted to demonstrate that the proposed method is more effective than previous methods.

  2. Alaska Program Point and Line Feature GIS Data from COMIDA, ANIMIDA and cANIMIDA Programs

    Data.gov (United States)

    Bureau of Ocean Energy Management, Department of the Interior — Alaska Program Map Service contains point and line features from the following BOEM Alaska Region environmental monitoring programs: Chukchi Sea Offshore Monitoring...

  3. Iris biometric system design using multispectral imaging

    Science.gov (United States)

    Widhianto, Benedictus Yohanes Bagus Y. B.; Nasution, Aulia M. T.

    2016-11-01

    An identity recognition system is a vital component that cannot be separated from life, iris biometric is one of the biometric that has the best accuracy reaching 99%. Usually, iris biometric systems use infrared spectrum lighting to reduce discomfort caused by radiation when the eye is given direct light, while the eumelamin that is forming the iris has the most flourescent radiation when given a spectrum of visible light. This research will be conducted by detecting iris wavelengths of 850 nm, 560 nm, and 590 nm, where the detection algorithm will be using Daugman algorithm by using a Gabor wavelet extraction feature, and matching feature using a Hamming distance. Results generated will be analyzed to identify how much differences there are, and to improve the accuracy of the multispectral biometric system and as a detector of the authenticity of the iris. The results obtained from the analysis of wavelengths 850 nm, 560 nm, and 590 nm respectively has an accuracy of 99,35 , 97,5 , 64,5 with a matching score of 0,26 , 0,23 , 0,37.

  4. Iris recognition as a biometric method after cataract surgery

    Directory of Open Access Journals (Sweden)

    Roizenblatt Jaime

    2004-01-01

    Full Text Available Abstract Background Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Methods Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. Results A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Conclusions Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  5. Iris recognition as a biometric method after cataract surgery.

    Science.gov (United States)

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  6. Aura: A Multi-Featured Programming Framework in Python

    Directory of Open Access Journals (Sweden)

    2010-09-01

    Full Text Available This paper puts forward the design, programming and application of innovative educational software, ‘Aura’ made using Python and PyQt Python bindings. The research paper presents a new concept of using a single tool to relate between syntaxes of various programming languages and algorithms. It radically increases their understanding and retaining capacity, since they can correlate between many programming languages. The software is a totally unorthodox attempt towards helping students who have their first tryst with programming languages. The application is designed to help students understand how algorithms work and thus, help them in learning multiple programming languages on a single platform using an interactive graphical user interface. This paper elucidates how using Python and PyQt bindings, a comprehensive feature rich application, that implements an interactive algorithm building technique, a web browser, multiple programming language framework, a code generator and a real time code sharing hub be embedded into a single interface. And also explains, that using Python as building tool, it requires much less coding than conventional feature rich applications coded in other programming languages, and at the same time does not compromise on stability, inter-operability and robustness of the application.

  7. Fusion of phase congruency and harris algorithm for extraction of iris corner points

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, G

    2015-12-01

    Full Text Available of reliable iris features. This work proposes a fusion of Phase congruency and Harris algorithm to detect corner features found within the arrangement of iris patterns. This fusion produces a feature vector with the exact location of corner features...

  8. A Novel Iris Segmentation Scheme

    Directory of Open Access Journals (Sweden)

    Chen-Chung Liu

    2014-01-01

    Full Text Available One of the key steps in the iris recognition system is the accurate iris segmentation from its surrounding noises including pupil, sclera, eyelashes, and eyebrows of a captured eye-image. This paper presents a novel iris segmentation scheme which utilizes the orientation matching transform to outline the outer and inner iris boundaries initially. It then employs Delogne-Kåsa circle fitting (instead of the traditional Hough transform to further eliminate the outlier points to extract a more precise iris area from an eye-image. In the extracted iris region, the proposed scheme further utilizes the differences in the intensity and positional characteristics of the iris, eyelid, and eyelashes to detect and delete these noises. The scheme is then applied on iris image database, UBIRIS.v1. The experimental results show that the presented scheme provides a more effective and efficient iris segmentation than other conventional methods.

  9. The FDSN Archive at the IRIS Data Management Center

    Directory of Open Access Journals (Sweden)

    T. Ahern

    1994-06-01

    Full Text Available In August of 1990, the IRIS Data Management Center (IRIS DMC was designated as the first FDSN Data Center. Since that time the IRIS DMC has also come to be known as the FDSN Archive. As the FDSN Archive, all member networks, through their own local Network Data Centers, routinely send data to the IRIS DMC. At the present time we have received data from seven member networks. These include: CNSN (Canada; CDSN (China; GEOSCOPE (France; Graefenberg (Germany; IRIS GSN (U.S.A.; MEDNET (Italy; POSEIDON (Japan. In addition to acting as the FDSN Archive, the IRIS DMC is responsible for archiving and distributing data from several sources. The Global Seismographie Network (GSN and the Program for Array Seismic Studies of the Continental Lithosphere (PASSCAL and the Joint Seismic Program (JSP are three IRIS programs that presently send data to the IRIS DMS. The DMC also archives data from some regional networks in the United States and in the Former Soviet Union (FSU. The DMC is one component of a larger Data Management System (DMS consisting of several components including two Data Collection Centers (DCCs, one Data Management Center (DMQ, a DMC Host at the University of Washington, a Wave form Quality Center (WQC, and the Moscow Data Analysis Center (MDC in Russia.

  10. Image compression with Iris-C

    Science.gov (United States)

    Gains, David

    2009-05-01

    Iris-C is an image codec designed for streaming video applications that demand low bit rate, low latency, lossless image compression. To achieve compression and low latency the codec features the discrete wavelet transform, Exp-Golomb coding, and online processes that construct dynamic models of the input video. Like H.264 and Dirac, the Iris-C codec accepts input video from both the YUV and YCOCG colour spaces, but the system can also operate on Bayer RAW data read directly from an image sensor. Testing shows that the Iris-C codec is competitive with the Dirac low delay syntax codec which is typically regarded as the state-of-the-art low latency, lossless video compressor.

  11. Mall Walking Program Environments, Features, and Participants: A Scoping Review.

    Science.gov (United States)

    Farren, Laura; Belza, Basia; Allen, Peg; Brolliar, Sarah; Brown, David R; Cormier, Marc L; Janicek, Sarah; Jones, Dina L; King, Diane K; Marquez, David X; Rosenberg, Dori E

    2015-08-13

    Walking is a preferred and recommended physical activity for middle-aged and older adults, but many barriers exist, including concerns about safety (ie, personal security), falling, and inclement weather. Mall walking programs may overcome these barriers. The purpose of this study was to summarize the evidence on the health-related value of mall walking and mall walking programs. We conducted a scoping review of the literature to determine the features, environments, and benefits of mall walking programs using the RE-AIM framework (reach, effectiveness, adoption, implementation, and maintenance). The inclusion criteria were articles that involved adults aged 45 years or older who walked in indoor or outdoor shopping malls. Exclusion criteria were articles that used malls as laboratory settings or focused on the mechanics of walking. We included published research studies, dissertations, theses, conference abstracts, syntheses, nonresearch articles, theoretical papers, editorials, reports, policy briefs, standards and guidelines, and nonresearch conference abstracts and proposals. Websites and articles written in a language other than English were excluded. We located 254 articles on mall walking; 32 articles met our inclusion criteria. We found that malls provided safe, accessible, and affordable exercise environments for middle-aged and older adults. Programmatic features such as program leaders, blood pressure checks, and warm-up exercises facilitated participation. Individual benefits of mall walking programs included improvements in physical, social, and emotional well-being. Limited transportation to the mall was a barrier to participation. We found the potential for mall walking programs to be implemented in various communities as a health promotion measure. However, the research on mall walking programs is limited and has weak study designs. More rigorous research is needed to define best practices for mall walking programs' reach, effectiveness, adoption

  12. Genetic programming approach to extracting features from remotely sensed imagery

    Energy Technology Data Exchange (ETDEWEB)

    Theiler, J. P. (James P.); Perkins, S. J. (Simon J.); Harvey, N. R. (Neal R.); Szymanski, J. J. (John J.); Brumby, Steven P.

    2001-01-01

    Multi-instrument data sets present an interesting challenge to feature extraction algorithm developers. Beyond the immediate problems of spatial co-registration, the remote sensing scientist must explore a complex algorithm space in which both spatial and spectral signatures may be required to identify a feature of interest. We describe a genetic programming/supervised classifier software system, called Genie, which evolves and combines spatio-spectral image processing tools for remotely sensed imagery. We describe our representation of candidate image processing pipelines, and discuss our set of primitive image operators. Our primary application has been in the field of geospatial feature extraction, including wildfire scars and general land-cover classes, using publicly available multi-spectral imagery (MSI) and hyper-spectral imagery (HSI). Here, we demonstrate our system on Landsat 7 Enhanced Thematic Mapper (ETM+) MSI. We exhibit an evolved pipeline, and discuss its operation and performance.

  13. Mall Walking Program Environments, Features, and Participants: A Scoping Review

    Science.gov (United States)

    Belza, Basia; Allen, Peg; Brolliar, Sarah; Brown, David R.; Cormier, Marc L.; Janicek, Sarah; Jones, Dina L.; King, Diane K.; Marquez, David X.; Rosenberg, Dori E.

    2015-01-01

    Introduction Walking is a preferred and recommended physical activity for middle-aged and older adults, but many barriers exist, including concerns about safety (ie, personal security), falling, and inclement weather. Mall walking programs may overcome these barriers. The purpose of this study was to summarize the evidence on the health-related value of mall walking and mall walking programs. Methods We conducted a scoping review of the literature to determine the features, environments, and benefits of mall walking programs using the RE-AIM framework (reach, effectiveness, adoption, implementation, and maintenance). The inclusion criteria were articles that involved adults aged 45 years or older who walked in indoor or outdoor shopping malls. Exclusion criteria were articles that used malls as laboratory settings or focused on the mechanics of walking. We included published research studies, dissertations, theses, conference abstracts, syntheses, nonresearch articles, theoretical papers, editorials, reports, policy briefs, standards and guidelines, and nonresearch conference abstracts and proposals. Websites and articles written in a language other than English were excluded. Results We located 254 articles on mall walking; 32 articles met our inclusion criteria. We found that malls provided safe, accessible, and affordable exercise environments for middle-aged and older adults. Programmatic features such as program leaders, blood pressure checks, and warm-up exercises facilitated participation. Individual benefits of mall walking programs included improvements in physical, social, and emotional well-being. Limited transportation to the mall was a barrier to participation. Conclusion We found the potential for mall walking programs to be implemented in various communities as a health promotion measure. However, the research on mall walking programs is limited and has weak study designs. More rigorous research is needed to define best practices for mall walking

  14. Iris - nimi marmortahvlilt / Tiit Tuumalu

    Index Scriptorium Estoniae

    Tuumalu, Tiit, 1971-

    2003-01-01

    Briti kirjanikust Iris Murdochist pajatava inglise-ameerika mängufilmist "Iris" eesti videolevisse jõudmise puhul. Võrreldakse inglise teatrilavastaja Richard Eyre filmidebüüti Elmo Nüganeni debüütfilmiga "Nimed marmortahvlil"

  15. Iris recognition using the JAVAVis Library

    Directory of Open Access Journals (Sweden)

    L.Martin García

    2008-12-01

    Full Text Available This project has been created to develop a biometric identification system through a man’s iris using a computer to perform the processing of the pictures. To develop this application, and to differentiate the project from others who have already implemented, we have used the image processing library JAVAVis and JAVA as a programming language.

  16. Iris reactor development

    Energy Technology Data Exchange (ETDEWEB)

    Paramonov, D.V.; Carelli, M.D. [Westinghouse Electric Corp., Baltimore, MD (United States); Miller, K. [BNFL, Inc., (United Kingdom); Lombardi, C.V.; Ricotti, M.E. [Polytechnic of Milan, Polimi (Italy); Todreas, N.E. [Masachussets Institute of Technology, MIT (United States); Greenspan, E. [University of California at Berkeley, UCB (United States); Yamamoto, K. [JAPC Japan Atomic Power Co., Tokyo (Japan); Nagano, A. [Mitsubishi Heavy Industries Ltd., Tokyo (Japan); Ninokata, H. [Tokyo Institut of Technology, TIT (Japan); Robertson, J. [Westinghouse and bechtel (United States); Oriolo, F. [Pisa Univ. (Italy)

    2001-07-01

    The development progress of the IRIS (International Reactor Innovative and Secure) nuclear power system is presented. IRIS is currently being developed by an international consortium of industry, laboratory, university and utility establishments, led by Westinghouse. It is aimed at achieving the four major objectives of the Generation IV nuclear systems, i.e., proliferation resistance, enhanced safety, economic competitiveness and reduced waste. The project first year activities, which are summarized here, were focused on core neutronics, in-vessel configuration, steam generator and containment design, safety approach and economic performance. Details of these studies are provided in parallel papers in these proceedings. (author)

  17. Iris Recognition for Partially Occluded Images: Methodology and Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    A. Poursaberi

    2007-01-01

    Full Text Available Accurate iris detection is a crucial part of an iris recognition system. One of the main issues in iris segmentation is coping with occlusion that happens due to eyelids and eyelashes. In the literature, some various methods have been suggested to solve the occlusion problem. In this paper, two different segmentations of iris are presented. In the first algorithm, a circle is located around the pupil with an appropriate diameter. The iris area encircled by the circular boundary is used for recognition purposes then. In the second method, again a circle is located around the pupil with a larger diameter. This time, however, only the lower part of the encircled iris area is utilized for individual recognition. Wavelet-based texture features are used in the process. Hamming and harmonic mean distance classifiers are exploited as a mixed classifier in suggested algorithm. It is observed that relying on a smaller but more reliable part of the iris, though reducing the net amount of information, improves the overall performance. Experimental results on CASIA database show that our method has a promising performance with an accuracy of 99.31%. The sensitivity of the proposed method is analyzed versus contrast, illumination, and noise as well, where lower sensitivity to all factors is observed when the lower half of the iris is used for recognition.

  18. Iris Recognition - Beyond One Meter

    Science.gov (United States)

    Matey, James R.; Kennell, Lauren R.

    Iris recognition Iris recognition is, arguably, the most robust form of biometric Biometrics identification. It has been deployed in large-scale systems that have been very effective. The systems deployed to date make use of iris Remote Biometric cameras that require significant user cooperation; that in turn imposes significant constraints on the deployment scenarios that are practical.

  19. A study on quality-adjusted impact of time lapse on iris recognition

    Science.gov (United States)

    Sazonova, Nadezhda; Hua, Fang; Liu, Xuan; Remus, Jeremiah; Ross, Arun; Hornak, Lawrence; Schuckers, Stephanie

    2012-06-01

    Although human iris pattern is widely accepted as a stable biometric feature, recent research has found some evidences on the aging effect of iris system. In order to investigate changes in iris recognition performance due to the elapsed time between probe and gallery iris images, we examine the effect of elapsed time on iris recognition utilizing 7,628 iris images from 46 subjects with an average of ten visits acquired over two years from a legacy database at Clarkson University. Taken into consideration the impact of quality factors such as local contrast, illumination, blur and noise on iris recognition performance, regression models are built with and without quality metrics to evaluate the degradation of iris recognition performance based on time lapse factors. Our experimental results demonstrate the decrease of iris recognition performance along with increased elapsed time based on two iris recognition system (the modified Masek algorithm and a commercial software VeriEye SDK). These results also reveal the significance of quality factors in iris recognition regression indicating the variability in match scores. According to the regression analysis, our study in this paper helps provide the quantified decrease on match scores with increased elapsed time, which indicates the possibility to implement the prediction scheme for iris recognition performance based on learning of impact on time lapse factors.

  20. A novel iris patterns matching algorithm of weighted polar frequency correlation

    Science.gov (United States)

    Zhao, Weijie; Jiang, Linhua

    2014-11-01

    Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.

  1. IRIS Toxicological Review of Trichloroacetic Acid (Tca) (Final Report)

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Trichloroacetic Acid: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  2. Challenges at different stages of an iris based biometric system

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Singla

    2012-04-01

    Full Text Available Iris recognition has been used for authentication for the past few years and is capable of positive/negative authenticationof an individual without any physical contact or intervention. This technique is being used mainly because of its uniqueness,stability, and reliability but still many challenges are being faced an the iris based recognition system. This paperpresents the difficulties faced in different modules, like the sensor module, preprocessing module, feature extraction module,and matching module of an iris biometric system.

  3. Fast Iris Segmentation by Rotation Average Analysis of Intensity-Inversed Image

    Science.gov (United States)

    Li, Wei; Jiang, Lin-Hua

    Iris recognition is a reliable and accurate biometric technique used in modern personnel identification system. Segmentation of the effective iris region is the base of iris feature encoding and recognition. In this paper, a novel method is presented for fast iris segmentation. There are two steps to finish the iris segmentation. The first step is iris location, which is based on rotation average analysis of intensity-inversed image and non-linear circular regression. The second step is eyelid detection. A new method to detect the eyelids utilizing a simplified mathematical model of arc with three free parameters is implemented for quick fitting. Comparatively, the conventional model with four parameters is less optimal. Experiments were carried out on both self-collected images and CASIA database. The results show that our method is fast and robust in segmenting the effective iris region with high tolerance of noise and scaling.

  4. Optimal Face-Iris Multimodal Fusion Scheme

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2016-06-01

    Full Text Available Multimodal biometric systems are considered a way to minimize the limitations raised by single traits. This paper proposes new schemes based on score level, feature level and decision level fusion to efficiently fuse face and iris modalities. Log-Gabor transformation is applied as the feature extraction method on face and iris modalities. At each level of fusion, different schemes are proposed to improve the recognition performance and, finally, a combination of schemes at different fusion levels constructs an optimized and robust scheme. In this study, CASIA Iris Distance database is used to examine the robustness of all unimodal and multimodal schemes. In addition, Backtracking Search Algorithm (BSA, a novel population-based iterative evolutionary algorithm, is applied to improve the recognition accuracy of schemes by reducing the number of features and selecting the optimized weights for feature level and score level fusion, respectively. Experimental results on verification rates demonstrate a significant improvement of proposed fusion schemes over unimodal and multimodal fusion methods.

  5. IRIS Toxicological Review and Summary Documents for ...

    Science.gov (United States)

    Carbon tetrachloride is a volatile haloalkane with a wide range of industrial and chemical applications. It is produced commercially from chlorination of a variety of low molecular weight hydrocarbons such as carbon disulfide, methanol, methane, propane, and ethylene dichloride. It is also produced by thermal chlorination in the production of tetrachloroethylene. Major uses of carbon tetrachloride have been in the recovery of tin from tin plating waste, in formulation of petrol additives and refrigerants, in metal degreasing and agricultural fumigants, in chlorination of organic compounds, in the production of semiconductors, in the reduction of fire hazard, as a solvent for rubber cement, and as a catalyst in polymer technology. Its production has been decreasing and it is no longer permitted in products intended for home use. Despite this ban, carbon tetrachloride has been detected at 314 hazardous waste sites. EPA's assessment of noncancer health effects and carcinogenic potential of carbon tetrachloride was last prepared and added to the IRIS database in 1991. The IRIS program is preparing an assessment that will incorporate health effects information available for carbon tetrachloride, and current risk assessment methods. The IRIS assessment for carbon tetrachloride will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity

  6. Integrated risk information system (IRIS)

    Energy Technology Data Exchange (ETDEWEB)

    Tuxen, L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRIS contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).

  7. Compact dynamic microfluidic iris array

    Science.gov (United States)

    Kimmle, Christina; Doering, Christoph; Steuer, Anna; Fouckhardt, Henning

    2011-09-01

    A dynamic microfluidic iris is realized. Light attenuation is achieved by absorption of an opaque liquid (e.g. black ink). The adjustment of the iris diameter is achieved by fluid displacement via a transparent elastomer (silicone) half-sphere. This silicone calotte is hydraulically pressed against a polymethylmethacrylate (PMMA) substrate as the bottom window, such that the opaque liquid is squeezed away, this way opening the iris. With this approach a dynamic range of more than 60 dB can be achieved with response times in the ms to s regime. The design allows the realization of a single iris as well as an iris array. So far the master for the molded silicone structure was fabricated by precision mechanics. The aperture diameter was changed continuously from 0 to 8 mm for a single iris and 0 to 4 mm in case of a 3 x 3 iris array. Moreover, an iris array was combined with a PMMA lens array into a compact module, the distance of both arrays equaling the focal length of the lenses. This way e.g. spatial frequency filter arrays can be realized. The possibility to extend the iris array concept to an array with many elements is demonstrated. Such arrays could be applied e.g. in light-field cameras.

  8. Iris classification based on sparse representations using on-line dictionary learning for large-scale de-duplication applications.

    Science.gov (United States)

    Nalla, Pattabhi Ramaiah; Chalavadi, Krishna Mohan

    2015-01-01

    De-duplication of biometrics is not scalable when the number of people to be enrolled into the biometric system runs into billions, while creating a unique identity for every person. In this paper, we propose an iris classification based on sparse representation of log-gabor wavelet features using on-line dictionary learning (ODL) for large-scale de-duplication applications. Three different iris classes based on iris fiber structures, namely, stream, flower, jewel and shaker, are used for faster retrieval of identities. Also, an iris adjudication process is illustrated by comparing the matched iris-pair images side-by-side to make the decision on the identification score using color coding. Iris classification and adjudication are included in iris de-duplication architecture to speed-up the identification process and to reduce the identification errors. The efficacy of the proposed classification approach is demonstrated on the standard iris database, UPOL.

  9. Statistical feature extraction based iris recognition system

    Indian Academy of Sciences (India)

    Atul Bansal

    1 Department of Electronics and Communication, G.L.A. University, 17-km stone, NH#2, Delhi-Mathura Road,. Mathura 281406, India. 2 Department of Electrical and Instrumentation Engineering, Thapar University, Patiala 147004, India. 3 Department of Computer Science and Engineering, Thapar University, Patiala ...

  10. Robust iris segmentation through parameterization of the Chan-Vese algorithm

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, G

    2015-06-01

    Full Text Available -Vese algorithm with pre-defined initial contour and curve evolution parameters for accurate segmentation. Preprocessing techniques to enhance and detect iris features for extraction. Labeling features of strongest pixel connectivity and using Harris algorithm...

  11. Efficient iris texture analysis method based on Gabor ordinal measures

    Science.gov (United States)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  12. Automatic quantification of iris color

    DEFF Research Database (Denmark)

    Christoffersen, S.; Harder, Stine; Andersen, J. D.

    2012-01-01

    An automatic algorithm to quantify the eye colour and structural information from standard hi-resolution photos of the human iris has been developed. Initially, the major structures in the eye region are identified including the pupil, iris, sclera, and eyelashes. Based on this segmentation, the ...

  13. A bibliography of IRIS-related publications, 2000-2011

    Science.gov (United States)

    Muco, B.

    2012-12-01

    Citations and acknowledgements in scientific journals can be an indicator of the role an organization has on the research of that field. Since its formation and incorporation in May 1984, the IRIS Consortium (Incorporated Research Institutions for Seismology) is mentioned more and more as a valuable source of data, instruments and programs in the literature of earth sciences. As a large organization with more than 100 member domestic institutes and about 40 international affiliates, obviously IRIS has a direct impact on the earth sciences through all its programs, projects, workshops, symposia, and news¬letters and as a lively forum for exchanging ideas. In order to maintain support from National Science Foundation (NSF) and the research community, it is important to document the continued use of IRIS facilities in basic research programs. IRIS maintains a database of articles that are based on the use of IRIS facilities or which reference use of IRIS data and resources. Articles in this database have been either been provided to IRIS by the authors or selected through an annual search of a number of prominent journals. A text version of the full bibliographic database is available on the IRIS website and a version in EndNote format is also provided. To provide a more complete bibliography and a consistent evaluation of temporal tends in publications, a special annual search began in 2000 which focused on a subset of key seismology and Earth science journals: Bulletin of Seismological Society of America, Journal of Geophysical Research, Seismological Research Letters, Geophysical Research Letters, Earth and Planetary Science Letters, Physics of the Earth and Planetary Interiors, Tectonophysics, Geophysical Journal International, Nature, Science, Geology and EOS. Using different search engines as Scirus, ScienceDirect, GeoRef, OCLC First Search, EASI Search, NASA Abstract Service etc. for online journals and publishers' databases, we searched for key words (IRIS

  14. Does iris change over time?

    Directory of Open Access Journals (Sweden)

    Hunny Mehrotra

    Full Text Available Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  15. Does iris change over time?

    Science.gov (United States)

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  16. Method of preliminary localization of the iris in biometric access control systems

    Science.gov (United States)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  17. Ultrasound biomicroscopic analysis of iris cysts.

    Science.gov (United States)

    Pedro-Aguilar, L; Fuentes-Cataño, C; Pedroza-Seres, M

    2016-02-01

    To describe the ultrasound biomicroscopic (UBM) features and complications associated with iris cysts. A retrospective case series. Thirteen patients with iris cysts were identified in a 10 year period study at a ophthalmologic reference Center in Mexico City. The variables included demographic data, ocular and medical history, clinical course, and complications. All patients were examined by UBM, and type, number, location, and acoustic characteristics of cysts were evaluated. Descriptive statistics were performed. Thirteen patients were included (8 men and 5 women). The mean age was 44.5 ± 15.5 years (range 6-70 years). The origin most prevalent was neuroepithelial (92.3%), and 7.7% had stromal cysts. Regarding to location 76.9% were found in the periphery, and 69.2% between meridians II and VI. All cysts showed a moderate to high reflectivity in the wall. Complications were present in 38.5% of cases (15.4% partial angle closure, 15.4% secondary angle closure glaucoma and 7.7% dyscoria). Most cysts are derived from iris pigmented epithelium, with a benign course and a minor rate of complications. The UBM is an indispensable tool that allows us to plan more specific and conservative treatments, with less damage to ocular structures and, therefore, better visual prognosis. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Bartus Iris biometrics

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, R.; Grace, W.

    1996-07-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). We won a 1994 R&D 100 Award for inventing the Bartas Iris Verification System. The system has been delivered to a sponsor and is no longer available to us. This technology can verify the identity of a person for purposes of access control, national security, law enforcement, forensics, counter-terrorism, and medical, financial, or scholastic records. The technique is non-invasive, psychologically acceptable, works in real-time, and obtains more biometric data than any other biometric except DNA analysis. This project sought to develop a new, second-generation prototype instrument.

  19. Iris recognition via plenoptic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J.; Boehnen, Chris Bensing; Bolme, David S.

    2017-11-07

    Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

  20. Iris Recognition Using Image Moments and k-Means Algorithm

    Directory of Open Access Journals (Sweden)

    Yaser Daanial Khan

    2014-01-01

    Full Text Available This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%.

  1. Iris recognition using image moments and k-means algorithm.

    Science.gov (United States)

    Khan, Yaser Daanial; Khan, Sher Afzal; Ahmad, Farooq; Islam, Saeed

    2014-01-01

    This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%.

  2. Iris Murdoch armastusest / Udo uibo

    Index Scriptorium Estoniae

    Uibo, Udo, 1956-

    2010-01-01

    Londoni Kingstoni ülikool omandas 50 000 naesterlingi eest 164 Iris Murdochi kirja prantsuse kirjanikule, keeleeksperimentaatorile Raymond Quenaule, millest selgub Murdochi ühepoolne ning vastamata jäänud tunne Quenau suhtes.

  3. Ankeny - Yellow Flag Iris Control

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This project aims to inventory and map all existing stands of yellow flag iris within wetland habitats at Ankeny NWR, treat them with herbicide in late spring and...

  4. Integrated Risk Information System (IRIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA?s Integrated Risk Information System (IRIS) is a compilation of electronic reports on specific substances found in the environment and their potential to cause...

  5. Evaluation of Genetic Diversity of Iris Genotypes (Iris spp Using ISSR

    Directory of Open Access Journals (Sweden)

    seyedeh zeinab attari

    2017-02-01

    demonstrate that ISSR marker is a simple, informative, reproducible and suitable approach to evaluation of molecular diversity and phylogenetic relationships in Iris spp. The highest genetic similarity was between species Iris kopetdaghensis and Iris fosteriana. This study revealed a significant variation especially between Iris kopetdaghensis and Iris songarica. Conclusions: The results of cluster analysis showed that molecular markers able to identify the species and genotypes within a species from each other. Results of this study showed that the use of molecular markers in breeding programs, especially fingerprinting is useful for lily. ISSR molecular markers have proved to be an efficient tool for studying genetic diversity and management of lily germplasm. . Also the result showed these genotypes have high genetic diversity, and the success in Iris breeding programs use to recommend Iranian local Iris.

  6. Quantitative study of the microvasculature and its endothelial cells in the porcine iris.

    Science.gov (United States)

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-03-01

    The roles of the iris microvasculature have been increasingly recognised in the pathogenesis of glaucoma and cataract; however limited information exists regarding the iris microvasculature and its endothelium. This study quantitatively assessed the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining of the porcine iris. The temporal long posterior ciliary artery of 11 isolated porcine eyes was cannulated, perfusion-fixed and labelled using silver nitrate. The iris microvasculature was studied for its distribution, orders and endothelial morphometrics. The density of three layers of microvasculature was measured. Endothelial cell length and width were measured for each vessel order. The iris has an unusual vascular distribution which consisted of abundant large vessels in the middle of the iris stroma, branching over a relatively short distance to the microvasculature located in the superficial and deep stroma as well as the pupil edge. The average vascular density of the middle, superficial, and deep layers were 38.9 ± 1.93%, 10.9 ± 1.61% and 8.0 ± 0.79% respectively. Multiple orders of iris vessels (capillary, 6 orders of arteries, and 4 orders of veins) with relatively large capillary and input arteries (319.5 ± 25.6 μm) were found. Significant heterogeneity of vascular diameter and shape of the endothelia was revealed in different orders of the iris vasculature. Detailed information of topography and endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. ANTIMICROBIAL ACTIVITY OF EXTRACTS OF IRIS HUNGARICA AND IRIS SIBIRICA

    Directory of Open Access Journals (Sweden)

    Kovalev V. M.

    2017-06-01

    Full Text Available Introduction. Referring to the latest data, infectious diseases command a large part of among the total number of pathologies in the world and are an important problem in medicine. The leading role in prevention and treatment of diseases of microbial origin belongs to antibacterial chemotherapeutic agents. Advantages of antibiotics of synthetic origin are the high activity compared to phytogenic drugs. But it is known that microorganisms can release the resistance to synthetic antibiotics, so the use of drugs based on the plant materials is appropriate: phytogenic drugs more rarely induce the formation of resistance of the strains of microorganisms, they have a gentle action, can be used for a long-term, have the low cost. Therefore, it is appropriate to examine the drug plants with the aim of determination their antibacterial activity.Iris hungarica Waldst et Kit. and Iris sibirica L. are the representatives of the family Iridaceae, genus Iris and they have a wide spectrum of the pharmacological activity. Biologically active substances that were recovered from plants of the genus Iris (tectoridin, iristectorigenin B, nigracin, kaempferol, quercetin, etc. exhibited an antitumor, antimicrobial, estrogenic, insecticidal, antiplasmatic, anticholinesterase action, they were the inhibitors of enzymes and exhibited the immunomodulatory properties, which made these plants perspective for the research study. Raw materials Irises are constituent components of more than 9 medicines. Materials and Methods. The objects of the study were the leaves and rhizomes of Iris hungarica and Iris sibirica that were prepared during the growing season in 2014 in the M.M. Gryshko National botanical garden (Kiev, Ukraine. The dry and lipophilic extracts from the leaves and rhizomes of Irises were used to establish the antimicrobial activity. For the study of extracts antimicrobial activity was used agar well diffusion method. According to the WHO recommendations the

  8. Particular features of development and realizations of purposeful complex programs in Ukraine

    Directory of Open Access Journals (Sweden)

    О.В. Самков

    2004-04-01

    Full Text Available  Features of development and realization of aviation purposeful complex programs in Ukraine are examined. The necessity of metrology securing of aviation programs as well as decision making process in the logistics system during complex programs development and realization. Examples from the modernization programs of aviation are analyzed.

  9. Dynamic iris biometry: a technique for enhanced identification

    Directory of Open Access Journals (Sweden)

    McDowell Douglas R

    2010-07-01

    Full Text Available Abstract Background The iris as a unique identifier is predicated on the assumption that the iris image does not alter. This does not consider the fact that the iris changes in response to certain external factors including medication, disease, surgery as well as longer term ageing changes. It is also part of a dynamic optical system that alters with light level and focussing distance. A means of distinguishing the features that do not alter over time from those that do is needed. This paper applies iris recognition algorithms to a newly acquired database of 186 iris images from four subjects. These images have greater magnification and detail than iris images in existing databases. Iris segmentation methods are tested on the database. A new technique that enhances segmentation is presented and compared to two existing methods. These are also applied to test the effects of pupil dilation in the identification process. Findings Segmentation results from all the images showed that using the proposed algorithm accurately detected pupil boundaries for 96.2% respectively of the images, which was an increase of 88.7% over the most commonly used algorithm. For the images collected, the proposed technique also showed significant improvement in detection of the limbal boundary compared to the detection rates using existing methods. With regard to boundary displacement errors, only slight errors were found with the proposed technique compared to extreme errors made when existing techniques were applied. As the pupil becomes more dilated, the success of identification is increasingly more dependent on the decision criterion used. Conclusions The enhanced segmentation technique described in this paper performs with greater accuracy than existing methods for the higher quality images collected in this study. Implementation of the proposed segmentation enhancement significantly improves pupil boundary detection and therefore overall iris segmentation. Pupil

  10. Feature Program: Project N.I.C.E.

    Science.gov (United States)

    Education Journal of the Institute for the Development of Indian Law, 1973

    1973-01-01

    The Northern Indian California Education Project, established in 1971, has pilot programs in 6 schools which reach out to 24 additional schools. The article lists project goals, the implementation of these goals, accomplishments, and available materials. (KM)

  11. Association of iris crypts with acute primary angle closure.

    Science.gov (United States)

    Koh, Victor; Chua, Jacqueline; Shi, Yuan; Thakku, Sri Gowtham; Lee, Ryan; Nongpiur, Monisha E; Baskaran, Mani; Kumar, Rajesh S; Perera, Shamira; Aung, Tin; Cheng, Ching-Yu

    2017-10-01

    To determine the relationship between iris surface features and acute primary angle closure (APAC) in eyes with angle closure. Case-control study involving Asian patients diagnosed with previous APAC, primary angle closure suspect (PACS), primary angle closure (PAC) and primary angle closure glaucoma (PACG) at an eye centre in Singapore between August 2012 and January 2015. Participants underwent ophthalmic examination and digital slit-lamp iris photography. Iris surface features were graded based on crypts, furrows and colour. Fellow eyes of APAC were compared with PACS and PAC/PACG eyes with regard to their iris surface features. Occurrence of APAC. A total of 309 patients (71 APAC, 139 PACS, 47 PAC and 52 PACG) were included (mean age: 67.7±7.2 years and 36.6% male). Compared with PACS, higher crypt grade was significantly associated with lower odds of APAC (OR=0.58 for one grade higher in crypt grade; p=0.027, adjusted for age, gender, ethnicity and pupil diameter). The results remained similar when compared with PAC/PACG group (OR=0.58 for one grade higher in crypt grade; p=0.043). We did not observe any significant associations between iris furrows or colour with presence of APAC. Our study comprising Asian eyes with angle closure suggests that the presence of a higher crypt grading may be protective for APAC. As such, assessing iris surface architecture for crypts could be a new measure for risk stratification of developing APAC in eyes with angle closure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Remodularizing Java Programs for Improved Locality of Feature Implementations in Source Code

    DEFF Research Database (Denmark)

    Olszak, Andrzej; Jørgensen, Bo Nørregaard

    2011-01-01

    Explicit traceability between features and source code is known to help programmers to understand and modify programs during maintenance tasks. However, the complex relations between features and their implementations are not evident from the source code of object-oriented Java programs. Conseque...

  13. Features of using multimedia technologies at lecturing programming

    Directory of Open Access Journals (Sweden)

    G. S. Ivanova

    2014-01-01

    Full Text Available The subject of study of this paper is multimedia capabilities, which are used for lectures on programming for undergraduate students to learn Computer Science and Engineering.The objective is to analyze the factors affecting the efficiency of lectures on programming, readable using multimedia, identifying the advantages and disadvantages of using presentations and process of creating and debugging programs in software environments demonstration, and to make recommendations on the use of illustrative material aimed at improving student's handout with the knowledge readable material.Scientific novelty of the material is to identify and analyze the factors influencing the effectiveness of teaching programming using multimedia as well as to make recommendations on the creation of illustrative material in the form of lecture presentations, analyse the negative side effects of presentations and opportunities to address them.It is stated that even at the initial stage of teaching in programming the amount of learning material and associated details in their records to which student's attention should be drawn, commensurate with the restrictions of psycho physiological capabilities defined for modern undergraduate students to remember and learn. The conclusion about expediency to improve lectures efficiency through the use of multimedia equipment capabilities is made.The types of illustrative material used in lectures on programming are listed and named, examples of illustrative material for presentation slides are analyzed. The positive results of the process of program creating, debugging and running directly in the programming environment during the lecture are underlined .As the merits of the multimedia-based lectures are marked a significant reduction of time to be required for material presentation ( from 10 to 30 % and the structured and with no errors in the program texts of lectures available for students. Negative effects of the multimedia

  14. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    Energy Technology Data Exchange (ETDEWEB)

    Karakaya, Mahmut [ORNL; Barstow, Del R [ORNL; Santos-Villalobos, Hector J [ORNL; Thompson, Joseph W [ORNL; Bolme, David S [ORNL; Boehnen, Chris Bensing [ORNL

    2013-01-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  15. Gaze estimation for off-angle iris recognition based on the biometric eye model

    Science.gov (United States)

    Karakaya, Mahmut; Barstow, Del; Santos-Villalobos, Hector; Thompson, Joseph; Bolme, David; Boehnen, Christopher

    2013-05-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ORNL biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  16. A new method for generating an invariant iris private key based on the fuzzy vault system.

    Science.gov (United States)

    Lee, Youn Joo; Park, Kang Ryoung; Lee, Sung Joo; Bae, Kwanghyuk; Kim, Jaihie

    2008-10-01

    Cryptographic systems have been widely used in many information security applications. One main challenge that these systems have faced has been how to protect private keys from attackers. Recently, biometric cryptosystems have been introduced as a reliable way of concealing private keys by using biometric data. A fuzzy vault refers to a biometric cryptosystem that can be used to effectively protect private keys and to release them only when legitimate users enter their biometric data. In biometric systems, a critical problem is storing biometric templates in a database. However, fuzzy vault systems do not need to directly store these templates since they are combined with private keys by using cryptography. Previous fuzzy vault systems were designed by using fingerprint, face, and so on. However, there has been no attempt to implement a fuzzy vault system that used an iris. In biometric applications, it is widely known that an iris can discriminate between persons better than other biometric modalities. In this paper, we propose a reliable fuzzy vault system based on local iris features. We extracted multiple iris features from multiple local regions in a given iris image, and the exact values of the unordered set were then produced using the clustering method. To align the iris templates with the new input iris data, a shift-matching technique was applied. Experimental results showed that 128-bit private keys were securely and robustly generated by using any given iris data without requiring prealignment.

  17. Iris-based authentication system with template protection and renewability

    Science.gov (United States)

    Ercole, Chiara; Campisi, Patrizio; Neri, Alessandro

    2007-10-01

    Biometrics is the most emerging technology for automatic people authentication, nevertheless severe concerns raised about security of such systems and users' privacy. In case of malicious attacks toward one or more components of the authentication system, stolen biometric features cannot be replaced. This paper focuses on securing the enrollment database and the communication channel between such database and the matcher. In particular, a method is developed to protect the stored biometric templates, adapting the fuzzy commitment scheme to iris biometrics by exploiting error correction codes tailored on template discriminability. The aforementioned method allows template renewability applied to iris based authentication and guarantees high security performing the match in the encrypted domain.

  18. Iris color and visual functions.

    Science.gov (United States)

    Nischler, Christian; Michael, Ralph; Wintersteller, Christine; Marvan, Patrick; van Rijn, Laurentius J; Coppens, Joris E; van den Berg, Thomas J T P; Emesz, Martin; Grabner, Günther

    2013-01-01

    The aim of this study was to evaluate if iris color is associated with differences in visual functions such as intraocular straylight (IOSL), contrast sensitivity (CS), or best-corrected visual acuity (BCVA). In this retrospective cohort study, which is a subgroup analysis of a large prospective trial about visual impairments in European car drivers, we included 853 persons between 20 and 80 years of age and without a history of ocular surgery or any eye disease including cataract. Subjects participated in an ophthalmological examination, grading of lens opacity, and the measurement of visual functions such as IOSL, CS, and BCVA. Dependent on iris color, participants were divided into four groups: light-blue, blue-grey, green-hazel, and brown. Independent of age, IOSL was significantly (all p values colored iris (1.14 log(IOSL) [95 % CI: 1.11-1.17]) compared to participants with blue-grey (1.07 log(IOSL) [95 % CI: 1.05-1.09]), green-hazel (1.06 log(IOSL) [95 % CI: 1.04-1.08]) or brown (1.06 log(IOSL) [95 % CI: 1.04-1.08]) iris color. CS was also lower in participants with light-blue pigmented irises (1.60 log(CS) [95 % CI: 1.58-1.62]) than in the other groups, but statistically significant (p = 0.013, Fisher's LSD test) only compared to brown iris color. For BCVA we could not found any difference between the four groups. We could show in this study that iris color has a significant impact on IOSL and to a lower degree on CS, but not on BCVA. Persons with light-blue iris color who showed significantly higher IOSL values therefore may experience disability glare in daily situations such as driving at night more often than others.

  19. Extended depth of field system for long distance iris acquisition

    Science.gov (United States)

    Chen, Yuan-Lin; Hsieh, Sheng-Hsun; Hung, Kuo-En; Yang, Shi-Wen; Li, Yung-Hui; Tien, Chung-Hao

    2012-10-01

    Using biometric signatures for identity recognition has been practiced for centuries. Recently, iris recognition system attracts much attention due to its high accuracy and high stability. The texture feature of iris provides a signature that is unique for each subject. Currently most commercial iris recognition systems acquire images in less than 50 cm, which is a serious constraint that needs to be broken if we want to use it for airport access or entrance that requires high turn-over rate . In order to capture the iris patterns from a distance, in this study, we developed a telephoto imaging system with image processing techniques. By using the cubic phase mask positioned front of the camera, the point spread function was kept constant over a wide range of defocus. With adequate decoding filter, the blurred image was restored, where the working distance between the subject and the camera can be achieved over 3m associated with 500mm focal length and aperture F/6.3. The simulation and experimental results validated the proposed scheme, where the depth of focus of iris camera was triply extended over the traditional optics, while keeping sufficient recognition accuracy.

  20. IDENTIFIKASI IRIS MATA MENGGUNAKAN TAPIS GABOR WAVELET DAN JARINGAN SYARAF TIRUAN LEARNING VECTOR QUANTIZATION (LVQ

    Directory of Open Access Journals (Sweden)

    Budi Setiyono

    2012-02-01

    Full Text Available Biometric represents the human identification method development using natural characteristic of humanbeing as its bases. Every iris has the detail and unique texture, even differ between right and left eye.Theeye iris identification process in this research are data acquisition, early processing, feature exctractionand classification. Algorithm used for classification of texture slice the eye is Gabor wavelet filtering, andclassification process of slice the eye texture will be used by a Artificial Neural Network LVQ. Recognitionthe value of feature vektor in each iris obtained from to the number of right recognition value or thepercentage of right one. The best recognition percentage is 87,5 %.

  1. Plateau Iris Distribution Across Anterior Segment Optical Coherence Tomography Defined Subgroups of Subjects With Primary Angle Closure Glaucoma.

    Science.gov (United States)

    Verma, Sushma; Nongpiur, Monisha E; Oo, Hnin H; Atalay, Eray; Goh, David; Wong, Tina T; Perera, Shamira A; Aung, Tin

    2017-10-01

    We previously identified three distinct subgroups of patients with primary angle closure glaucoma (PACG) based on anterior segment optical coherence tomography (ASOCT) imaging. Group 1 was characterized by a large iris area with deepest anterior chambers, group 2 by a large lens vault (LV) and shallow anterior chamber depth (ACD), and group 3 displayed intermediate values across iris area, LV, and ACD. The purpose of the present study was to determine the distribution of plateau iris in these subgroups using ultrasound biomicroscopy (UBM) features. UBM images of the 210 subjects who were previously enrolled for the ASOCT subgrouping analysis and had undergone laser peripheral iridotomy were assessed and graded by a single glaucoma fellowship trained clinician. Plateau iris was defined as the presence of all the following UBM criteria in at least two quadrants: anteriorly directed ciliary body, absent ciliary sulcus, iris angulation, flat iris plane, and iridoangle touch. Of 210 subjects, 23 were excluded due to poor-quality images. Based on standardized UBM criteria, the overall prevalence of plateau iris was 36.9% (n = 187). The proportion of plateau iris was similar across the three groups (subgroup 1:35.4% (n = 29); subgroup 2:39.0% (n = 32); subgroup 3:34.8% (n = 8), P = 0.87). On multiple logistic regression analysis, iris thickness at 750 μm from the scleral spur (IT750) was the only variable associated with plateau iris (odds ratio: 1.5/100 μm increase in iris thickness [IT], P = 0.04). The proportion of plateau iris was similar across the three ASOCT-based PACG subgroups and more than one-third of subjects with PACG were diagnosed with plateau iris based on standardized UBM criteria. In addition, we noted that eyes with increased peripheral IT have an increased likelihood of plateau iris.

  2. Diagnostic potential of iris cross-sectional imaging in albinism using optical coherence tomography.

    Science.gov (United States)

    Sheth, Viral; Gottlob, Irene; Mohammad, Sarim; McLean, Rebecca J; Maconachie, Gail D E; Kumar, Anil; Degg, Christopher; Proudlock, Frank A

    2013-10-01

    To characterize in vivo anatomic abnormalities of the iris in albinism compared with healthy controls using anterior segment optical coherence tomography (AS-OCT) and to explore the diagnostic potential of this technique for albinism. We also investigated the relationship between iris abnormalities and other phenotypical features of albinism. Prospective cross-sectional study. A total of 55 individuals with albinism and 45 healthy controls. We acquired 4.37×4.37-mm volumetric scans (743 A-scans, 50 B-scans) of the nasal and temporal iris in both eyes using AS-OCT (3-μm axial resolution). Iris layers were segmented and thicknesses were measured using ImageJ software. Iris transillumination grading was graded using Summers and colleagues' classification. Retinal OCT, eye movement recordings, best-corrected visual acuity (BCVA), visual evoked potential (VEP), and grading of skin and hair pigmentation were used to quantify other phenotypical features associated with albinism. Iris AS-OCT measurements included (1) total iris thickness, (2) stroma/anterior border (SAB) layer thickness, and (3) posterior epithelial layer (PEL) thickness. Correlation with other phenotypical measurements, including (1) iris transillumination grading, (2) retinal layer measurements at the fovea, (3) nystagmus intensity, (4) BCVA, (5) VEP asymmetry, (6) skin pigmentation, and (7) hair pigmentation (of head hair, lashes, and brows). The mean iris thickness was 10.7% thicker in controls (379.3 ± 44.0 μm) compared with the albinism group (342.5 ± 52.6 μm; P>0.001), SAB layers were 5.8% thicker in controls (315.1 ± 43.8 μm) compared with the albinism group (297.7 ± 50.0 μm; P=0.044), and PEL was 44.0% thicker in controls (64.1 ± 11.7 μm) compared with the albinism group (44.5 ± 13.9 μm; Palbinism. Phenotypic features of albinism, such as skin and hair pigmentation, BCVA, and nystagmus intensity, were significantly correlated to AS-OCT iris thickness measurements. We have

  3. Early Career Investigator Opportunities in Geophysics with IRIS

    Science.gov (United States)

    Colella, H.; Sumy, D. F.; Schutt, D.

    2016-12-01

    Early career geoscientists face many challenges as they transition from senior level graduate students into postdoctoral researchers, tenure-track faculty positions, or the vast array of employment opportunities outside of academia. However, few receive adequate mentoring or guidance on how to successfully make the leap from graduate school to a fulfilling career. In recognition of these hurdles and challenges, the Incorporated Research Institutions for Seismology (IRIS) created an early-career investigator (ECI) program in 2011 to help reduce barriers for newly minted scientists, researchers, and educators on their path to success. The core mission of the ECI program is to organize practical resources and professional development opportunities for ECIs. The initiative has encouraged and supported collaboration between ECIs and senior scientists through colloquium lectureships and visiting scientist collaborations, which aimed to increase the visibility of ECIs and their research and to promote interaction between junior and senior scientists outside of their home institutions. Additionally, ECI-centric events are held at various national meetings to showcase the range of career paths available in geophysics, openly discuss the challenges ECIs face (e.g., work-life balance, job search difficulties, teaching challenges), expose participants to the ECI program's initiatives and resources, and better inform IRIS about the needs of the community. Post-workshop evaluations reveal ECIs are eager to have exposure to a variety of workforce options and a forum in which to ask difficult questions. Of note, there is a variety of cultural knowledge and expectations assumed in both the academic and professional worlds that is often not formally disseminated. The ECI program aims to better understand and facilitate transfer of this knowledge and reduce barriers to success for ECIs from both traditional and non-traditional backgrounds. The program also features webinars focused

  4. What Genes Tell about Iris Appearance

    DEFF Research Database (Denmark)

    Harder, Stine; Christoffersen, Susanne R.; Johansen, Peter

    2012-01-01

    are performed supporting that this SNP is very important for eye color expression. With the suggested image characterizations we are able to investigate the correlation between the phenotypic iris appearance and specific SNPs. This has potential for further investigation of the relation between DNA and iris......Predicting phenotypes based on genotypes is generally hard, but has shown good results for prediction of iris color. We propose to correlate the appearance of iris with DNA. Six single-nucleotide polymorphisms (SNPs) have previously been shown to correlate with human iris color, and we demonstrate...... that especially one of the six SNPs are correlated with iris appearance. To perform this analysis we need a method to model the iris appearance, and we suggest an iris characterization based on a bag of visual words, which gives us a similarity measure between images of eyes. We have a dataset of 215 eye images...

  5. IRIS Toxicological Review of Naphthalene (1998 Final)

    Science.gov (United States)

    EPA announced the release of the final report, Toxicological Review of Naphthalene: in support of the Integrated Risk Information System (IRIS). The updated Summary for Naphthalene and accompanying toxicological review have been added to the IRIS Database.

  6. Eyelid Localization for Iris Identification

    Directory of Open Access Journals (Sweden)

    T. Ea

    2008-12-01

    Full Text Available This article presents a new eyelid localization algorithm based on a parabolic curve fitting. To deal with eyelashes, low contrast or false detection due to iris texture, we propose a two steps algorithm. First, possible edge candidates are selected by applying edge detection on a restricted area inside the iris. Then, a gradient maximization is applied along every parabola, on a larger area, to refine parameters and select the best one. Experiments have been conducted on a database of 151 iris that have been manually segmented. The performance evaluation is carried out by comparing the segmented images obtained by the proposed method with the manual segmentation. The results are satisfactory in more than 90% of the cases.

  7. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (Final Report)

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This ...

  8. Ekspert i undervisning - IRIS Connect

    DEFF Research Database (Denmark)

    Wullum, Annemette Heine; Eriksen, Frits Hedegaard

    2014-01-01

    Ekspert i undervisning – IRIS Connect Credoet bag de seneste års mange læreruddannelsesreformer har været, at flere og dybere kundskaber vil styrke de studerendes forudsætninger for at løse opgaverne i pædagogisk praksis. Et forhold, som bliver overset i forbindelse med uddannelsesreformerne, er...... praksis, og hvad ”effektiv” undervisning er. Hovedantagelserne bag projektet er, at de studerendes personbundne kundskaber kan synliggøres, at deres lægmandsopfattelser af, hvad ”effektiv” undervisning er, kan udfordres gennem analyser og drøftelser, og at brugen af IRIS Connects dataindsamlings- og...

  9. Articulation Therapy Using Distinctive Feature Analysis to Structure the Training Program: Two Case Studies.

    Science.gov (United States)

    Ruder, Kenneth F.; Bunce, Betty H.

    1981-01-01

    Two case reports of 4 and 5 year old children describe the rationale and procedures for structuring an articulation therapy program on the basis of distinctive feature analysis of the child's articulation problems. (Author/DB)

  10. Virtual cohorts and face-to-face recruitment: Strategies for cultivating the next generation of the IRIS Community

    Science.gov (United States)

    Hubenthal, M.; Wysession, M. E.; Aster, R. C.

    2009-12-01

    surveys we believe that the best method to advertise REU programs has shifted away from the traditional and expensive hardcopy fliers tacked to bulletin board in the halls of science departments. Instead we have found that the two most common methods for students to learn about the program were by visiting the IRIS website to view video clips or slideshow presentations and via personal notification/encouragement from faculty or staff at their institutions. The importance of personal notification was even more pronounced for applicants from minority serving institutions. Given the importance both the web and faculty advising in encouraging students to apply, the IRIS REU has adopted the following three recruitment strategies: 1) Engage students through the website by providing access to traditional text and photos, narrated video clips and other media, as well as links to previous intern’s blogs, 2) Empower and encourage faculty to recruit students by providing resources for easy use in classes such as annotated slideshows and narrated videos, and 3) Reach out to minority students personally through a speaker series featuring minority alumni of the IRIS REU program.

  11. CFD modeling of the IRIS pressurizer dynamic

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, Ronny R.; Montesinos, Maria E.; Garcia, Carlos; Bueno, Elizabeth D.; Mazaira, Leorlen R., E-mail: rsanz@instec.cu, E-mail: mmontesi@instec.cu, E-mail: cgh@instec.cu, E-mail: leored1984@gmail.com [Instituto Superior de Tecnologias y Ciencias Aplicadas (InSTEC), La Habana (Cuba); Bezerra, Jair L.; Lira, Carlos A.B. Oliveira, E-mail: jair.lima@ufpe.br, E-mail: cabol@ufpe.br [Universida Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2015-07-01

    Integral layout of nuclear reactor IRIS makes possible the elimination of the spray system, which is usually used to mitigate in-surge transient and also help to Boron homogenization. The study of transients with deficiencies in the Boron homogenization in this technology is very important, because they can cause disturbances in the reactor power and insert a strong reactivity in the core. The detailed knowledge of the behavior of multiphase multicomponent flows is challenging due to the complex phenomena and interactions at the interface. In this context, the CFD modeling is employed in the design of equipment in the nuclear industry as it allows predicting accidents or predicting their performance in dissimilar applications. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial CFD code CFX. A symmetric tri dimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of four phases and also takes into account the heat losses. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX. Moreover, two subdomains and several additional variables are defined to monitoring the boron dilution sequences and condensation-evaporation rates in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  12. Diffusion of Courses with World Wide Web Features: Perceptions of Journalism and Mass Communication Program Administrators.

    Science.gov (United States)

    Sutherland, Patrick J.

    2003-01-01

    Examines perceptions of top administrators concerning courses with Web features at Association of Schools of Journalism and Mass Communication (ASJMC) programs. Studies the imperatives and pressures to implement courses with Web features as well as resistances to implementation. Suggests that administrators perceive an extensive set of needs and…

  13. Visualizing how Seismic Waves Propagate Across Seismic Arrays using the IRIS DMS Ground Motion Visualization (GMV) Products and Codes

    Science.gov (United States)

    Taber, J.; Bahavar, M.; Bravo, T. K.; Butler, R. F.; Kilb, D. L.; Trabant, C.; Woodward, R.; Ammon, C. J.

    2011-12-01

    Data from dense seismic arrays can be used to visualize the propagation of seismic waves, resulting in animations effective for teaching both general and advanced audiences. One of the first visualizations of this type was developed using Objective C code and EarthScope/USArray data, which was then modified and ported to the Matlab platform and has now been standardized and automated as an IRIS Data Management System (IRIS-DMS) data product. These iterative code developments and improvements were completed by C. Ammon, R. Woodward and M. Bahavar, respectively. Currently, an automated script creates Ground Motion Visualizations (GMVs) for all global earthquakes over magnitude 6 recorded by EarthScope's USArray Transportable Array (USArray TA) network. The USArray TA network is a rolling array of 400 broadband stations deployed on a uniform 70-km grid. These near real-time GMV visualizations are typically available for download within 4 hours or less of their occurrence (see: www.iris.edu/dms/products/usarraygmv/). The IRIS-DMS group has recently added a feature that allows users to highlight key elements within the GMVs, by providing an online tool for creating customized GMVs. This new interface allows users to select the stations, channels, and time window of interest, adjust the mapped areal extent of the view, and specify high and low pass filters. An online tutorial available from the IRIS Education and Public Outreach (IRIS-EPO) website, listed below, steps through a teaching sequence that can be used to explain the basic features of the GMVs. For example, they can be used to demonstrate simple concepts such as relative P, S and surface wave velocities and corresponding wavelengths for middle-school students, or more advanced concepts such as the influence of focal mechanism on waveforms, or how seismic waves converge at an earthquake's antipode. For those who desire a greater level of customization, including the ability to use the GMV framework with data

  14. PLOT3D/AMES, UNIX SUPERCOMPUTER AND SGI IRIS VERSION (WITH TURB3D)

    Science.gov (United States)

    Buning, P.

    1994-01-01

    five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In addition to providing the advantages of performing complex

  15. PLOT3D/AMES, UNIX SUPERCOMPUTER AND SGI IRIS VERSION (WITHOUT TURB3D)

    Science.gov (United States)

    Buning, P.

    1994-01-01

    five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In addition to providing the advantages of performing complex

  16. Engineering a Light-Attenuating Artificial Iris.

    Science.gov (United States)

    Shareef, Farah J; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-04-01

    Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage.

  17. Cistos primários do epitélio pigmentar da íris e corpo ciliar: aspectos de biomicroscopia ultra-sônica Primary cysts of the iris and ciliary body pigment epithelium: ultrasound biomicroscopy features

    Directory of Open Access Journals (Sweden)

    Bernadete Ayres

    2000-10-01

    Full Text Available Objetivo: Descrever as características, incidência e distribuição dos cistos primários de epitélio pigmentar de íris e corpo ciliar ao exame de biomicroscopia ultra-sônica, que devem ser diferenciados de lesões sólidas. Métodos: Foram estudados de modo retrospectivo os prontuários de 73 pacientes, 82 olhos, com diagnóstico ecográfico de cisto primário de íris ou corpo ciliar durante o período de janeiro/97 a dezembro/99. Utilizou-se o biomicroscópio ultra-sônico, aplicando técnicas padronizadas de imersão. Resultados: À biomicroscopia ultra-sônica os cistos caracterizaram-se por apresentarem paredes finas e regulares, e conteúdo anecóico. Quarenta e oito pacientes (65,7% eram do sexo feminino. A maior incidência (28,8% ocorreu para o grupo incluído no intervalo de 20 a 29 anos de idade. Observou-se uma característica distribuição, predominantemente nos quadrantes temporais inferiores. Conclusões: A biomicroscopia ultra-sônica mostrou-se útil no diagnóstico de cistos primários do epitélio pigmentar da íris e do corpo ciliar, auxiliando na diferenciação de patologias tumorais e avaliando possíveis complicações. O conhecimento dos critérios ecográficos e da distribuição epidemiológica facilitam o diagnóstico destas lesões.Purpose: To describe the ultrasound biomicroscopic characteristics, incidence, distribution and location of primary cysts of the iris and ciliary body pigment epithelium, and to differentiate them from solid lesions. Methods: A retrospective study was performed through a review of charts of 73 patients, 82 eyes, with echographic diagnosis of primary cysts of the iris and ciliary body pigment epithelium during a 36-month period (January/97 through December/99. All examinations were performed using an ultrasound biomicroscope applying standard immersion techniques. Results: Ultrasound biomicroscopy revealed typical findings of the primary cysts of the pigment epithelium such as thin

  18. Identity Recognizing using Iris Scan with multiple frames of Video

    OpenAIRE

    Asha Latha Bandi; Vishnu Priya Thotakura; Suneetha Ravi

    2012-01-01

    The field of iris biometrics has been significant research over the last decade. At this point, iris capture has become a main stream technology with wide acceptance. A general iris recognition systemworks with four different steps. 1. Capturing the image from the eye. 2. Extracting iris from the processed image. 3. Transforming the raw image coordinates into normalized polar coordinates. 4. Finally the iris code is compared with known iris code for identification of a person. Iris performanc...

  19. PLOT3D/AMES, SGI IRIS VERSION (WITH TURB3D)

    Science.gov (United States)

    Buning, P.

    1994-01-01

    five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In each of these areas, the IRIS implementation of PLOT3D offers

  20. PLOT3D/AMES, SGI IRIS VERSION (WITHOUT TURB3D)

    Science.gov (United States)

    Buning, P.

    1994-01-01

    five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In each of these areas, the IRIS implementation of PLOT3D offers

  1. Features of circular training as a part of strength training program for dancer

    OpenAIRE

    Олександрова [Veronika Aleksandrova], Вероніка Анатоліївна; Шиян [Vladimir Shiyan], Віктор Володимирович

    2013-01-01

    says about the results of the experimental program which has been worked out and theoretically substantiated. The program includes two ways of strength training which are strength and stamina development. The program consists of three weeklong micro cycles (units): first week – drawing unit, second week – strength unit, third week – stamina development unit. Circular trainings were carried out according to individual differences of the dancers. The analysis of the literature about features of...

  2. Alpha antagonists and intraoperative floppy iris syndrome: A spectrum

    Directory of Open Access Journals (Sweden)

    Sharif A Issa

    2008-07-01

    Full Text Available Sharif A Issa, Omar H Hadid, Oliver Baylis, Margaret DayanDepartment of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UKBackground: To determine occurrence of features of intraoperative floppy iris syndrome (IFIS during cataract surgery in patients taking systemic alpha-antagonists (AA.Methods: We prospectively studied patients on AA and who underwent phacoemulsification. The following were recorded: pupil diameter preoperatively, iris flaccidity, iris prolapse and peroperative miosis.Results: We studied 40 eyes of 31 subjects. Mean age was 78 years. Overall, 14 eyes (13 patients showed signs of IFIS: 9/13 (69% eyes of patients on tamsulosin, 1/18 (6% eyes in the doxazosin group, 2/2 prazosin patients, 1/4 eyes in the indoramin group, and 1/2 eyes in two patients on a combination of doxazosin and tamsulosin. Most cases (92% had only one or two signs of IFIS. Bilateral cataract surgery was undertaken in 9 patients but only one patient (on tamsulosin had features of IFIS in both eyes, while 4 patients (2 on tamsulosin and 2 on other AA showed signs of IFIS in one eye only, and 4 patients did not show IFIS in either eye.Conclusion: Most AA were associated with IFIS, but it tends to present as a spectrum of signs rather than full triad originally described. Tamsulosin was most likely to be associated with IFIS; however, its intake does not necessarily mean that IFIS will occur. For patients on AA, the behavior of the iris intraoperatively in one eye is a poor predictor of the other eye. Surgeons should anticipate the occurrence of IFIS in any patient on AA.Keywords: alpha blocker, alpha antagonist, cataract surgery, intraoperative floppy iris syndrome, tamsulosin.

  3. A Novel Approach for Regenerating a Secure and Reliable Password using Iris and Fingerprint

    OpenAIRE

    SOROUSH SHIEKHALHOKAMAII; MOHAMMAD AMIN PIRBONYEH

    2013-01-01

    Cryptography - biological authentications are mechanisms that attempt to identify users by combining unique features such as physical and behavioral characteristics. The old method which was based on passwords (e.g., public key, AES, etc.) can be easily discovered by attackers. In order to improve local security key, this paper presents a method that uses biological fingerprints and iris patterns to generate cryptographic keys. In this method, fingerprint and iris images are collected from th...

  4. Successful Bullying Prevention Programs: Influence of Research Design, Implementation Features, and Program Components

    Directory of Open Access Journals (Sweden)

    Bryanna Hahn Fox

    2012-12-01

    Full Text Available Bullying prevention programs have been shown to be generally effective in reducing bullying and victimization. However, the effects are relatively small in randomized experiments and greater in quasi-experimental and age-cohort designs. Programs that are more intensive and of longer duration (for both children and teachers are more effective, as are programs containing more components. Several program components are associated with large effect sizes, including parent training or meetings and teacher training. These results should inform the design and evaluation of anti-bullying programs in the future, and a system ofaccreditation of effective programs.

  5. The best bits in an iris code.

    Science.gov (United States)

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2009-06-01

    Iris biometric systems apply filters to iris images to extract information about iris texture. Daugman's approach maps the filter output to a binary iris code. The fractional Hamming distance between two iris codes is computed and decisions about the identity of a person are based on the computed distance. The fractional Hamming distance weights all bits in an iris code equally. However, not all the bits in an iris code are equally useful. Our research is the first to present experiments documenting that some bits are more consistent than others. Different regions of the iris are compared to evaluate their relative consistency, and contrary to some previous research, we find that the middle bands of the iris are more consistent than the inner bands. The inconsistent-bit phenomenon is evident across genders and different filter types. Possible causes of inconsistencies, such as segmentation, alignment issues, and different filters are investigated. The inconsistencies are largely due to the coarse quantization of the phase response. Masking iris code bits corresponding to complex filter responses near the axes of the complex plane improves the separation between the match and nonmatch Hamming distance distributions.

  6. Using Hierarchical Latent Dirichlet Allocation to Construct Feature Tree for Program Comprehension

    Directory of Open Access Journals (Sweden)

    Xiaobing Sun

    2017-01-01

    Full Text Available Program comprehension is an important task faced by developers during software maintenance. With the increasing complexity of evolving systems, program comprehension becomes more and more difficult. In practice, programmers are accustomed to getting a general view of the features in a software system and then finding the interesting or necessary files to start the understanding process. Given a system, developers may need a general view of the system. The traditional view of a system is shown in a package-class structure which is difficult to understand, especially for large systems. In this article, we focus on understanding the system in both feature view and file structure view. This article proposes an approach to generate a feature tree based on hierarchical Latent Dirichlet Allocation (hLDA, which includes two hierarchies, the feature hierarchy and file structure hierarchy. The feature hierarchy shows the features from abstract level to detailed level, while the file structure hierarchy shows the classes from whole to part. Empirical results show that the feature tree can produce a view for the features and files, and the clustering of classes in the package in our approach is better (in terms of recall than the other clustering approach, that is, hierarchical clustering.

  7. Deep learning architecture for iris recognition based on optimal Gabor filters and deep belief network

    Science.gov (United States)

    He, Fei; Han, Ye; Wang, Han; Ji, Jinchao; Liu, Yuanning; Ma, Zhiqiang

    2017-03-01

    Gabor filters are widely utilized to detect iris texture information in several state-of-the-art iris recognition systems. However, the proper Gabor kernels and the generative pattern of iris Gabor features need to be predetermined in application. The traditional empirical Gabor filters and shallow iris encoding ways are incapable of dealing with such complex variations in iris imaging including illumination, aging, deformation, and device variations. Thereby, an adaptive Gabor filter selection strategy and deep learning architecture are presented. We first employ particle swarm optimization approach and its binary version to define a set of data-driven Gabor kernels for fitting the most informative filtering bands, and then capture complex pattern from the optimal Gabor filtered coefficients by a trained deep belief network. A succession of comparative experiments validate that our optimal Gabor filters may produce more distinctive Gabor coefficients and our iris deep representations be more robust and stable than traditional iris Gabor codes. Furthermore, the depth and scales of the deep learning architecture are also discussed.

  8. Amblyopia secondary to iris cyst.

    Science.gov (United States)

    López-Arroquia, T E; Avendaño-Cantos, E M; Mesa-Varona, D; Gálvez-Martínez, J; López-Romero, S; Nuñez-Plascencia, R; González del Valle, F

    2014-12-01

    A 5 year-old child diagnosed with moderate anisometropic amblyopia secondary to primary cyst of iris pigment epithelium. He was evaluated with ultrasound biomicroscopy (BMU) and optical coherence tomography (OCT) of anterior segment. The OCT, although with some limitations, is a useful tool to study the anterior segment. It is probably more recommendable than BMU in the childhood. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  9. Intracellular cytoskeleton and junction proteins of endothelial cells in the porcine iris microvasculature.

    Science.gov (United States)

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-11-01

    and shape of the endothelia. Detailed information of the topography and intracellular structure and junction proteins of the endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris vasculature in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Lentes plegables suturadas a iris

    Directory of Open Access Journals (Sweden)

    Dunia Cruz Izquierdo

    Full Text Available Para la corrección quirúrgica de la afaquia existen en la actualidad varias técnicas quirúrgicas que permiten fijar los lentes intraoculares plegables o rígidos en cámara posterior suturados al iris o al sulcus ciliar. En estas circunstancias el cirujano determinará cuándo, dónde y el tipo de lente mejor a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de movimiento de mano a 1 m. Se le realizó implante secundario de lente intraocular plegable de cámara posterior suturada al iris. En el examen biomicroscópico en lámpara de hendidura del ojo izquierdo se observó midriasis media paralítica, refracción dinámica de +11,00 (0,6 y tensión ocular normal. Se le realizó examen por bimicroscopía indirecta sin alteración. Al mes de operado la agudeza visual mejor corregida alcanzó la unidad de visión. Las complicaciones presentadas fueron ovalización de la pupila y depósitos de pigmentos de iris en el lente intraocular.

  11. CDIS: Circle Density Based Iris Segmentation

    Science.gov (United States)

    Gupta, Anand; Kumari, Anita; Kundu, Boris; Agarwal, Isha

    Biometrics is an automated approach of measuring and analysing physical and behavioural characteristics for identity verification. The stability of the Iris texture makes it a robust biometric tool for security and authentication purposes. Reliable Segmentation of Iris is a necessary precondition as an error at this stage will propagate into later stages and requires proper segmentation of non-ideal images having noises like eyelashes, etc. Iris Segmentation work has been done earlier but we feel it lacks in detecting iris in low contrast images, removal of specular reflections, eyelids and eyelashes. Hence, it motivates us to enhance the said parameters. Thus, we advocate a new approach CDIS for Iris segmentation along with new algorithms for removal of eyelashes, eyelids and specular reflections and pupil segmentation. The results obtained have been presented using GAR vs. FAR graphs at the end and have been compared with prior works related to segmentation of iris.

  12. Iris analysis for biometric recognition systems

    CERN Document Server

    Bodade, Rajesh M

    2014-01-01

    The book presents three most significant areas in Biometrics and Pattern Recognition. A step-by-step approach for design and implementation of Dual Tree Complex Wavelet Transform (DTCWT) plus Rotated Complex Wavelet Filters (RCWF) is discussed in detail. In addition to the above, the book provides detailed analysis of iris images and two methods of iris segmentation. It also discusses simplified study of some subspace-based methods and distance measures for iris recognition backed by empirical studies and statistical success verifications.

  13. IRIS thermal balance test within ESTEC LSS

    Science.gov (United States)

    Messidoro, Piero; Ballesio, Marino; Vessaz, J. P.

    1988-01-01

    The Italian Research Interim Stage (IRIS) thermal balance test was successfully performed in the ESTEC Large Space Simulator (LSS) to qualify the thermal design and to validate the thermal mathematical model. Characteristics of the test were the complexity of the set-up required to simulate the Shuttle cargo bay and allowing IRIS mechanism actioning and operation for the first time in the new LSS facility. Details of the test are presented, and test results for IRIS and the LSS facility are described.

  14. Computational cameras for moving iris recognition

    Science.gov (United States)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  15. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    Science.gov (United States)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  16. Diode Laser Transscleral Cyclophotocoagulation in the Treatment of Refractory Glaucoma with Iris Melanocytoma

    Directory of Open Access Journals (Sweden)

    Mei-Ju Chen

    2008-10-01

    Full Text Available Iris melanocytoma is a rare melanocytic nevus with distinctive clinical and pathologic features. Secondary glaucoma may develop rapidly and respond poorly to glaucoma medication in some cases. However, few data are available in the literature with respect to the appropriate treatment for refractory glaucoma associated with iris melanocytoma. Herein, we present a 28-year-old man with blurred vision and an elevated intraocular pressure (IOP of 40 mmHg in his right eye while on multiple glaucoma medications. A dark brown lobulated iris mass with surrounding small pigmented lesions was noted between the 4 and 5:30 o'clock positions. Sector iridectomy was performed and pathologic examination revealed an iris melanocytoma. After surgery, antiglaucomatous medications still failed to control IOP. The patient then underwent diode laser transscleral cyclophotocoagulation (TSCP. At the last follow-up of 15 months, IOP had returned to normal without the need for medication.

  17. Iris identification system based on Fourier coefficients and singular value decomposition

    Science.gov (United States)

    Somnugpong, Sawet; Phimoltares, Suphakant; Maneeroj, Saranya

    2011-12-01

    Nowadays, both personal identification and classification are very important. In order to identify the person for some security applications, physical or behavior-based characteristics of individuals with high uniqueness might be analyzed. Biometric becomes the mostly used in personal identification purpose. There are many types of biometric information currently used. In this work, iris, one kind of personal characteristics is considered because of its uniqueness and collectable. Recently, the problem of various iris recognition systems is the limitation of space to store the data in a variety of environments. This work proposes the iris recognition system with small-size of feature vector causing a reduction in space complexity term. For this experiment, each iris is presented in terms of frequency domain, and based on neural network classification model. First, Fast Fourier Transform (FFT) is used to compute the Discrete Fourier Coefficients of iris data in frequency domain. Once the iris data was transformed into frequency-domain matrix, Singular Value Decomposition (SVD) is used to reduce a size of the complex matrix to single vector. All of these vectors would be input for neural networks for the classification step. With this approach, the merit of our technique is that size of feature vector is smaller than that of other techniques with the acceptable level of accuracy when compared with other existing techniques.

  18. Combining heterogeneous features for colonic polyp detection in CTC based on semi-definite programming

    Science.gov (United States)

    Wang, Shijun; Yao, Jianhua; Petrick, Nicholas A.; Summers, Ronald M.

    2009-02-01

    Colon cancer is the second leading cause of cancer-related deaths in the United States. Computed tomographic colonography (CTC) combined with a computer aided detection system provides a feasible combination for improving colonic polyps detection and increasing the use of CTC for colon cancer screening. To distinguish true polyps from false positives, various features extracted from polyp candidates have been proposed. Most of these features try to capture the shape information of polyp candidates or neighborhood knowledge about the surrounding structures (fold, colon wall, etc.). In this paper, we propose a new set of shape descriptors for polyp candidates based on statistical curvature information. These features, called histogram of curvature features, are rotation, translation and scale invariant and can be treated as complementing our existing feature set. Then in order to make full use of the traditional features (defined as group A) and the new features (group B) which are highly heterogeneous, we employed a multiple kernel learning method based on semi-definite programming to identify an optimized classification kernel based on the combined set of features. We did leave-one-patient-out test on a CTC dataset which contained scans from 50 patients (with 90 6-9mm polyp detections). Experimental results show that a support vector machine (SVM) based on the combined feature set and the semi-definite optimization kernel achieved higher FROC performance compared to SVMs using the two groups of features separately. At a false positive per patient rate of 7, the sensitivity on 6-9mm polyps using the combined features improved from 0.78 (Group A) and 0.73 (Group B) to 0.82 (p<=0.01).

  19. IRIS Toxicological Review of Trichloroacetic Acid (Tca) (Final ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Trichloroacetic Acid: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. The draft Toxicological Review of Trichloroacetic Acid provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  20. Engineering a Light-Attenuating Artificial Iris

    Science.gov (United States)

    Shareef, Farah J.; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-01-01

    Purpose Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. Methods The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Results Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Conclusions Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage. PMID:27116547

  1. Real-Time IRI driven by GIRO data

    Science.gov (United States)

    Galkin, Ivan; Huang, Xueqin; Reinisch, Bodo; Bilitza, Dieter; Vesnin, Artem

    Real-time extensions of the empirical International Reference Ionosphere (IRI) model are based on assimilative techniques that preserve the IRI formalism which is optimized for the description of climatological ionospheric features. The Global Ionosphere Radio Observatory (GIRO) team has developed critical parts of an IRI Real Time Assimilative Model (IRTAM) for the global ionospheric plasma distribution using measured data available in real time from ~50 ionosondes of the GIRO network, The current assimilation results present global assimilative maps of foF2 and hmF2 that reproduce available data at the sensor sites and smoothly return to the climatological specifications when and where the data are missing, and are free from artificial sharp gradients and short-lived artifacts when viewed in time progression. Animated real-time maps of foF2 and hmF2 are published with a few minutes latency at http://giro.uml.edu/IRTAM/. Our real-time IRI modeling uses morphing, a technique that transforms the climatological ionospheric specifications to match the observations by iteratively computing corrections to the original coefficients of the diurnal/spatial expansions, used in IRI to map the key ionospheric characteristics, while keeping the IRI expansion basis formalism intact. Computation of the updated coefficient set for a given point in time includes analysis of the latest 24-hour history of observations, which allows the morphing technique to sense evolving ionospheric dynamics even with a sparse sensor network. A Non-linear Error Compensation Technique for Associative Restoration (NECTAR), one of the features in our morphing approach, has been in operation at the Lowell GIRO Data Center since 2013. The cornerstone of NECTAR is a recurrent neural network optimizer that is responsible for smoothing the transitions between the grid cells where observations are available. NECTAR has proved suitable for real-time operations that require the assimilation code to be

  2. Iris Image Classification Based on Hierarchical Visual Codebook.

    Science.gov (United States)

    Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang

    2014-06-01

    Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.

  3. Multi-Objective Genetic Programming with Redundancy-Regulations for Automatic Construction of Image Feature Extractors

    Science.gov (United States)

    Watchareeruetai, Ukrit; Matsumoto, Tetsuya; Takeuchi, Yoshinori; Kudo, Hiroaki; Ohnishi, Noboru

    We propose a new multi-objective genetic programming (MOGP) for automatic construction of image feature extraction programs (FEPs). The proposed method was originated from a well known multi-objective evolutionary algorithm (MOEA), i.e., NSGA-II. The key differences are that redundancy-regulation mechanisms are applied in three main processes of the MOGP, i.e., population truncation, sampling, and offspring generation, to improve population diversity as well as convergence rate. Experimental results indicate that the proposed MOGP-based FEP construction system outperforms the two conventional MOEAs (i.e., NSGA-II and SPEA2) for a test problem. Moreover, we compared the programs constructed by the proposed MOGP with four human-designed object recognition programs. The results show that the constructed programs are better than two human-designed methods and are comparable with the other two human-designed methods for the test problem.

  4. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  5. Multi-Patches IRIS Based Person Authentication System Using Particle Swarm Optimization and Fuzzy C-Means Clustering

    Science.gov (United States)

    Shekar, B. H.; Bhat, S. S.

    2017-05-01

    Locating the boundary parameters of pupil and iris and segmenting the noise free iris portion are the most challenging phases of an automated iris recognition system. In this paper, we have presented person authentication frame work which uses particle swarm optimization (PSO) to locate iris region and circular hough transform (CHT) to device the boundary parameters. To undermine the effect of the noise presented in the segmented iris region we have divided the candidate region into N patches and used Fuzzy c-means clustering (FCM) to classify the patches into best iris region and not so best iris region (noisy region) based on the probability density function of each patch. Weighted mean Hammimng distance is adopted to find the dissimilarity score between the two candidate irises. We have used Log-Gabor, Riesz and Taylor's series expansion (TSE) filters and combinations of these three for iris feature extraction. To justify the feasibility of the proposed method, we experimented on the three publicly available data sets IITD, MMU v-2 and CASIA v-4 distance.

  6. [Aniridia-IOL and artificial iris reconstruction].

    Science.gov (United States)

    Thomas, B C; Rabsilber, T M; Auffarth, G U

    2013-08-01

    Aniridia is defined as missing iris tissue which can be partial, subtotal or total. Characteristic clinical symptoms include photophobia and decreased visual acuity due to an increased light perception. In addition, disturbing cosmetic problems are prevalent. Modern iris reconstruction implants offer visual and cosmetic rehabilitation. Amongst them are aniridia intraocular lenses (IOL), iris segment implants and the "artificial iris". Different overall and pupil diameters are available for total or partial implants. At the same time aphakia or cataract can be treated when using aniridia IOLs. Intra- and extracapsular fixation is possible. The "artificial iris" can be folded and implanted through small incisions. The aesthetic results are improved significantly due to customised colour selection providing increased patient satisfaction postoperatively. Georg Thieme Verlag KG Stuttgart · New York.

  7. Spermatogenesis-specific features of the meiotic program in Caenorhabditis elegans.

    Directory of Open Access Journals (Sweden)

    Diane C Shakes

    2009-08-01

    Full Text Available In most sexually reproducing organisms, the fundamental process of meiosis is implemented concurrently with two differentiation programs that occur at different rates and generate distinct cell types, sperm and oocytes. However, little is known about how the meiotic program is influenced by such contrasting developmental programs. Here we present a detailed timeline of late meiotic prophase during spermatogenesis in Caenorhabditis elegans using cytological and molecular landmarks to interrelate changes in chromosome dynamics with germ cell cellularization, spindle formation, and cell cycle transitions. This analysis expands our understanding C. elegans spermatogenesis, as it identifies multiple spermatogenesis-specific features of the meiotic program and provides a framework for comparative studies. Post-pachytene chromatin of spermatocytes is distinct from that of oocytes in both composition and morphology. Strikingly, C. elegans spermatogenesis includes a previously undescribed karyosome stage, a common but poorly understood feature of meiosis in many organisms. We find that karyosome formation, in which chromosomes form a constricted mass within an intact nuclear envelope, follows desynapsis, involves a global down-regulation of transcription, and may support the sequential activation of multiple kinases that prepare spermatocytes for meiotic divisions. In spermatocytes, the presence of centrioles alters both the relative timing of meiotic spindle assembly and its ultimate structure. These microtubule differences are accompanied by differences in kinetochores, which connect microtubules to chromosomes. The sperm-specific features of meiosis revealed here illuminate how the underlying molecular machinery required for meiosis is differentially regulated in each sex.

  8. A Multiobjective Genetic Programming-Based Ensemble for Simultaneous Feature Selection and Classification.

    Science.gov (United States)

    Nag, Kaustuv; Pal, Nikhil R

    2016-02-01

    We present an integrated algorithm for simultaneous feature selection (FS) and designing of diverse classifiers using a steady state multiobjective genetic programming (GP), which minimizes three objectives: 1) false positives (FPs); 2) false negatives (FNs); and 3) the number of leaf nodes in the tree. Our method divides a c -class problem into c binary classification problems. It evolves c sets of genetic programs to create c ensembles. During mutation operation, our method exploits the fitness as well as unfitness of features, which dynamically change with generations with a view to using a set of highly relevant features with low redundancy. The classifiers of i th class determine the net belongingness of an unknown data point to the i th class using a weighted voting scheme, which makes use of the FP and FN mistakes made on the training data. We test our method on eight microarray and 11 text data sets with diverse number of classes (from 2 to 44), large number of features (from 2000 to 49 151), and high feature-to-sample ratio (from 1.03 to 273.1). We compare our method with a bi-objective GP scheme that does not use any FS and rule size reduction strategy. It depicts the effectiveness of the proposed FS and rule size reduction schemes. Furthermore, we compare our method with four classification methods in conjunction with six features selection algorithms and full feature set. Our scheme performs the best for 380 out of 474 combinations of data sets, algorithm and FS method.

  9. The features of teaching methods of programming in the system of supplementary education in informatics and ICT

    National Research Council Canada - National Science Library

    Наталья Геннадьевна Саблукова

    2010-01-01

    The model of formation of the rational contents of teaching to programming in described in the article in view of specificity of supplementary education and features of visual surroundings of programming...

  10. IRIS

    African Journals Online (AJOL)

    Esem

    Reported here is the case series of six infants presenting with immune reconstitution syndrome following the initiation of antiretroviral therapy. (ARV). The infants had no BCG scars at the time of starting ARVs and the mean duration of appearance of the cold abscess / lymphadenitis on the ipsilateral side of the BCG site was ...

  11. IRIS

    African Journals Online (AJOL)

    Esem

    shown to be inherently resistant to isoniazide and acquire resistance to rifampicin during therapy has been demonstrated in HIV infected infants with BCG. 9 disease . This has far reaching consequencies in the management of infants with BCG lymphadenothay / cold abscesses who may progress to BCG disease. Case no.

  12. LASSOing the MUSTANG: Using Tools Developed by IRIS for Actionable Seismic Data Quality Assessment

    Science.gov (United States)

    Frassetto, A.; Sumy, D. F.; Casey, R. E.; Woodward, R.; Ahern, T. K.

    2016-12-01

    MUSTANG, short for Modular Utility for STAtistical kNowledge Gathering, is a system developed by IRIS Data Services to bring data quality analysis web services to the IRIS DMC, covering the entirety of the data archive from past to present time. It provides station operators and earth scientists ready access to measurements that are scientifically useful and reflect the state of instrumentation that record seismic data. LASSO (Latest Assessment of Seismic Station Observations) is a software client, developed by Instrumental Software Technologies Inc. in conjunction with IRIS Instrumentation Services, which allows the viewer to download, display, sort, and analyze values of different metrics from MUSTANG. LASSO runs within a web-browser, allowing its user to interactively select from a number of preset metric groupings, or develop a more customized query. For many networks archiving data with the DMC, MUSTANG metrics are now available within days, making LASSO an ideal tool for assessing network status. Here, we demonstrate the features of LASSO and how Instrumentation Services commonly uses both LASSO and MUSTANG directly to provide actionable reports and visualizations of data quality. We also highlight the Mustang Data Browser, a tool for the simplified, rapid display of MUSTANG metrics developed by Data Services. Those interested in learning more about LASSO (lasso.iris.edu), MUSTANG (http://service.iris.edu/mustang/), and the Data Browser (https://ds.iris.edu/mustang/databrowser/) are encouraged to use these tools and visit our presentation.

  13. Epileptic MEG Spike Detection Using Statistical Features and Genetic Programming with KNN.

    Science.gov (United States)

    Alotaiby, Turky N; Alrshoud, Saud R; Alshebeili, Saleh A; Alhumaid, Majed H; Alsabhan, Waleed M

    2017-01-01

    Epilepsy is a neurological disorder that affects millions of people worldwide. Monitoring the brain activities and identifying the seizure source which starts with spike detection are important steps for epilepsy treatment. Magnetoencephalography (MEG) is an emerging epileptic diagnostic tool with high-density sensors; this makes manual analysis a challenging task due to the vast amount of MEG data. This paper explores the use of eight statistical features and genetic programing (GP) with the K-nearest neighbor (KNN) for interictal spike detection. The proposed method is comprised of three stages: preprocessing, genetic programming-based feature generation, and classification. The effectiveness of the proposed approach has been evaluated using real MEG data obtained from 28 epileptic patients. It has achieved a 91.75% average sensitivity and 92.99% average specificity.

  14. Epileptic MEG Spike Detection Using Statistical Features and Genetic Programming with KNN

    Directory of Open Access Journals (Sweden)

    Turky N. Alotaiby

    2017-01-01

    Full Text Available Epilepsy is a neurological disorder that affects millions of people worldwide. Monitoring the brain activities and identifying the seizure source which starts with spike detection are important steps for epilepsy treatment. Magnetoencephalography (MEG is an emerging epileptic diagnostic tool with high-density sensors; this makes manual analysis a challenging task due to the vast amount of MEG data. This paper explores the use of eight statistical features and genetic programing (GP with the K-nearest neighbor (KNN for interictal spike detection. The proposed method is comprised of three stages: preprocessing, genetic programming-based feature generation, and classification. The effectiveness of the proposed approach has been evaluated using real MEG data obtained from 28 epileptic patients. It has achieved a 91.75% average sensitivity and 92.99% average specificity.

  15. Systematic Review: Concept and Tool Development with Application in the Integrated Risk Information System (IRIS) Assessment Process

    Science.gov (United States)

    Systematic Review: Concept and tool development with application to the National Toxicology Program (NTP) and the Integrated Risk Information System (IRIS) Assessment Processes. There is growing interest within the environmental health community to incorporate systematic review m...

  16. Iris phenotypes and pigment dispersion caused by genes influencing pigmentation.

    Science.gov (United States)

    Anderson, Michael G; Hawes, Norman L; Trantow, Colleen M; Chang, Bo; John, Simon W M

    2008-10-01

    Spontaneous mutations altering mouse coat colors have been a classic resource for discovery of numerous molecular pathways. Although often overlooked, the mouse iris is also densely pigmented and easily observed, thus representing a similarly powerful opportunity for studying pigment cell biology. Here, we present an analysis of iris phenotypes among 16 mouse strains with mutations influencing melanosomes. Many of these strains exhibit biologically and medically relevant phenotypes, including pigment dispersion, a common feature of several human ocular diseases. Pigment dispersion was identified in several strains with mutant alleles known to influence melanosomes, including beige, light, and vitiligo. Pigment dispersion was also detected in the recently arising spontaneous coat color variant, nm2798. We have identified the nm2798 mutation as a missense mutation in the Dct gene, an identical re-occurrence of the slaty light mutation. These results suggest that dysregulated events of melanosomes can be potent contributors to the pigment dispersion phenotype. Combined, these findings illustrate the utility of studying iris phenotypes as a means of discovering new pathways, and re-linking old ones, to processes of pigmented cells in health and disease.

  17. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  18. Role of Arbuscular Mycorrhizal Fungi on Iris

    Directory of Open Access Journals (Sweden)

    CHEN Yuan

    2014-06-01

    Full Text Available For efficiency using the amphibious plant iris to restore polluted water, the promoting effect of different arbuscular mycorrhiza fungi(AMFon iris was investigated, by monitoring the plant growth index, the physicochemical properties of the soil and the plant photosynthesis indexes. The result showed that the promoting effects of the AMF on the aboveground part and the underground part of the iris were based on different mechanism. For the underground part of the iris, the AMF stimulated its growth through the nutrient enrichment which was performed by the enormous hypha network. The nitrogen absorbing rate of the G. mosseae and the G. intraradices infected iris increased about 71.75% and 42.55%, and the phosphorous absorbing rate increased 8.36% and 9.5% separately. For the aboveground part of the iris, the AMF strengthened the conductance of the leaves’ stomas to control the balance between the net photosynthesis rate and the transpiration rate, so that the utilization rate of water resources was optimized, the metabolic rate was accelerated and the growth of the plant was promoted eventually. In this study, the promoting effect of the G. mosseae on the photosynthesis rate of the iris was significantly better than that of the G. intraradices(P<0.05.

  19. IRIS Toxicological Review of Libby Amphibole Asbestos ...

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of Libby Amphibole Asbestos that will appear in the Integrated Risk Information System (IRIS) database. The project supports OSWER and Region 8 site clean-up and related risk management initiatives at this Superfund site. As with all IRIS assessments, the draft document will undergo agency review, OMB/interagency review and independent external peer review before being included on the IRIS data base.

  20. SEGMENTATION AND QUALITY ANALYSIS OF LONG RANGE CAPTURED IRIS IMAGE

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-05-01

    Full Text Available The iris segmentation plays a major role in an iris recognition system to increase the performance of the system. This paper proposes a novel method for segmentation of iris images to extract the iris part of long range captured eye image and an approach to select best iris frame from the iris polar image sequences by analyzing the quality of iris polar images. The quality of iris image is determined by the frequency components present in the iris polar images. The experiments are carried out on CASIA-long range captured iris image sequences. The proposed segmentation method is compared with Hough transform based segmentation and it has been determined that the proposed method gives higher accuracy for segmentation than Hough transform.

  1. Biometric iris image acquisition system with wavefront coding technology

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Yang, Hsi-Wen; Huang, Shao-Hung; Li, Yung-Hui; Tien, Chung-Hao

    2013-09-01

    Biometric signatures for identity recognition have been practiced for centuries. Basically, the personal attributes used for a biometric identification system can be classified into two areas: one is based on physiological attributes, such as DNA, facial features, retinal vasculature, fingerprint, hand geometry, iris texture and so on; the other scenario is dependent on the individual behavioral attributes, such as signature, keystroke, voice and gait style. Among these features, iris recognition is one of the most attractive approaches due to its nature of randomness, texture stability over a life time, high entropy density and non-invasive acquisition. While the performance of iris recognition on high quality image is well investigated, not too many studies addressed that how iris recognition performs subject to non-ideal image data, especially when the data is acquired in challenging conditions, such as long working distance, dynamical movement of subjects, uncontrolled illumination conditions and so on. There are three main contributions in this paper. Firstly, the optical system parameters, such as magnification and field of view, was optimally designed through the first-order optics. Secondly, the irradiance constraints was derived by optical conservation theorem. Through the relationship between the subject and the detector, we could estimate the limitation of working distance when the camera lens and CCD sensor were known. The working distance is set to 3m in our system with pupil diameter 86mm and CCD irradiance 0.3mW/cm2. Finally, We employed a hybrid scheme combining eye tracking with pan and tilt system, wavefront coding technology, filter optimization and post signal recognition to implement a robust iris recognition system in dynamic operation. The blurred image was restored to ensure recognition accuracy over 3m working distance with 400mm focal length and aperture F/6.3 optics. The simulation result as well as experiment validates the proposed code

  2. Perbaikan Kualitas Citra Iris Mata Untuk Pengenalan Pola (Biometric)

    OpenAIRE

    Heksaputra, Dadang; Wijaya, Dhina Puspasari; Nilawati, Sri

    2015-01-01

    Mata merupakan bagian dari kelima panca indra dari tubuh manusia. Mata mempuyai salah satu bagian disebut iris mata. Iris adalah salah satu organ bagian dalam dari mata terletak di belakang kornea dan di depan lensa. Fungsi utama dari iris mata adalah mengatur ukuran (besarnya) pupil. Banyaknya cahaya masuk ke dalam pupil jatuh pada retina mata dan diatur oleh otot–otot dalam iris. Iris mata setiap manusia memiliki pola berbeda sehingga dapat digunakan untuk kepentingan identifikasi seseorang...

  3. Deep Learning-Based Iris Segmentation for Iris Recognition in Visible Light Environment

    Directory of Open Access Journals (Sweden)

    Muhammad Arsalan

    2017-11-01

    Full Text Available Existing iris recognition systems are heavily dependent on specific conditions, such as the distance of image acquisition and the stop-and-stare environment, which require significant user cooperation. In environments where user cooperation is not guaranteed, prevailing segmentation schemes of the iris region are confronted with many problems, such as heavy occlusion of eyelashes, invalid off-axis rotations, motion blurs, and non-regular reflections in the eye area. In addition, iris recognition based on visible light environment has been investigated to avoid the use of additional near-infrared (NIR light camera and NIR illuminator, which increased the difficulty of segmenting the iris region accurately owing to the environmental noise of visible light. To address these issues; this study proposes a two-stage iris segmentation scheme based on convolutional neural network (CNN; which is capable of accurate iris segmentation in severely noisy environments of iris recognition by visible light camera sensor. In the experiment; the noisy iris challenge evaluation part-II (NICE-II training database (selected from the UBIRIS.v2 database and mobile iris challenge evaluation (MICHE dataset were used. Experimental results showed that our method outperformed the existing segmentation methods.

  4. Fusion of hand vein, iris and fingerprint for person identity verification based on Bayesian theory

    Science.gov (United States)

    Li, Xiuyan; Liu, Tiegen; Deng, Shichao; Wang, Yunxin

    2009-11-01

    Biometric identification is an important guarantee for social security. In recent years, as the development of social and economic, the more accuracy and safety of identification are required. The person identity verification systems that use a single biometric appear inherent limitations in accuracy, user acceptance, universality. Limitations of unimodal biometric systems can be overcome by using multimodal biometric systems, which combines the conclusions made by a number of unrelated biometrics indicators. Aiming at the limitations of unimodal biometric identification, a recognition algorithm for multimodal biometric fusion based on hand vein, iris and fingerprint was proposed. To verify person identity, the hand vein images, iris images and fingerprint images were preprocessed firstly. The region of interest (ROI) of hand vein image was obtained and filtered to reduce image noises. The multiresolution analysis theory was utilized to extract the texture information of hand vein. The iris image was preprocessed through iris localization, eyelid detection, image normalization and image enhancement, and then the feature code of iris was extracted from the detail images obtained using wavelet transform. The texture feature information represented fingerprint pattern was extracted after filtering and image enhancement. The Bayesian theorem was employed to realize the fusion at the matching score level and the fusion recognition result was finally obtained. The experimental results were presented, which showed that the recognition performance of the proposed fusion method was obviously higher than that of single biometric recognition algorithm. It had verified the efficiency of the proposed method for biometrics.

  5. Exploration of Genetic Programming Optimal Parameters for Feature Extraction from Remote Sensed Imagery

    Science.gov (United States)

    Gao, P.; Shetty, S.; Momm, H. G.

    2014-11-01

    Evolutionary computation is used for improved information extraction from high-resolution satellite imagery. The utilization of evolutionary computation is based on stochastic selection of input parameters often defined in a trial-and-error approach. However, exploration of optimal input parameters can yield improved candidate solutions while requiring reduced computation resources. In this study, the design and implementation of a system that investigates the optimal input parameters was researched in the problem of feature extraction from remotely sensed imagery. The two primary assessment criteria were the highest fitness value and the overall computational time. The parameters explored include the population size and the percentage and order of mutation and crossover. The proposed system has two major subsystems; (i) data preparation: the generation of random candidate solutions; and (ii) data processing: evolutionary process based on genetic programming, which is used to spectrally distinguish the features of interest from the remaining image background of remote sensed imagery. The results demonstrate that the optimal generation number is around 1500, the optimal percentage of mutation and crossover ranges from 35% to 40% and 5% to 0%, respectively. Based on our findings the sequence that yielded better results was mutation over crossover. These findings are conducive to improving the efficacy of utilizing genetic programming for feature extraction from remotely sensed imagery.

  6. Correlation of iris biometrics and DNA

    DEFF Research Database (Denmark)

    Harder, Stine; Clemmensen, Line Katrine Harder; Dahl, Anders Bjorholm

    2013-01-01

    The presented work concerns prediction of complex human phenotypes from genotypes. We were interested in correlating iris color and texture with DNA. Our data consist of 212 eye images along with DNA: 32 single-nucleotide polymorphisms (SNPs). We used two types of biometrics to describe the eye...... images: One for iris color and one for iris texture. Both biometrics were high dimensional and a sparse principle component analysis (SPCA) reduced the dimensions and resulted in a representation of data with good interpretability. The correlations between the sparse principal components (SPCs....... The SNPs (rs12896399, rs3733542, rs6475555, rs12913832) and (rs12896399, rs3733542, rs12913832) had the highest correlation to the canonical variable for color and texture, respectively. Three of the most contributing SNPs were the same for both biometrics, revealing a covariance between iris color...

  7. IRIS Bimonthly Public Meeting (Oct 2014)

    Science.gov (United States)

    The meeting was held to obtain input from the scientific community and the public on studies and data that will be used in the assessments of Diisononyl Phthalate (DINP) and Hexavalent Chromium (Cr(VI)) that are under IRIS development.

  8. Quality assessment for online iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2015-01-01

    Full Text Available -1 Computer Science & Information Technology (CS & IT), Dubai, UAE, 23-24 January 2015 Quality assessment for online iris images Sisanda Makinana, Tendani Malumedzha, and Fulufhelo V Nelwamondo Modelling and Digital Science, CSIR, Pretoria, South...

  9. An Application for Descriptive Nearness: Iris Recognition

    Directory of Open Access Journals (Sweden)

    Polat Kadirhan

    2017-12-01

    Full Text Available Near Set Theory has various applications in the literature. In this paper, using the concept descriptive nearness, we show how to perform iris recognition. This process has a few algorithms given via Mathematica Script Language.

  10. Residential immersive life skills programs for youth with disabilities: service providers' perceptions of experiential benefits and key program features.

    Science.gov (United States)

    King, Gillian; McPherson, Amy; Kingsnorth, Shauna; Stewart, Debra; Glencross-Eimantas, Tanya; Gorter, Jan Willem; Jones-Galley, Kimberlea; Morrison, Andrea; Isihi, Ana Maria

    2015-01-01

    The objective was to determine service providers' perceptions of the experiential benefits of residential immersive life skills (RILS) programs for youth with disabilities, along with important program features. Thirty-seven service providers from three RILS programs took part in qualitative interviews. Themes were derived using a phenomenological approach. There were perceived benefits for youth, and also for parents and service providers. Study themes concerned the process of youth empowerment, life-changing experiences for youth and parents, and changed service provider views affecting practice. Youth changes were attributed to the residential group format and afforded opportunities, which included being away from home, navigating public transportation, directing attendant services, and sharing intense learning and social experiences with peers. Youth were seen to experience important personal changes in life skills, self-confidence, self-understandings, and self-advocacy. Perceived benefits for parents included realizations concerning their child's abilities and new hope for the future. Service providers indicated changes in their knowledge, perspectives, and approach to practice. The findings suggest that life skills programs should be intentionally designed to provide challenging experiential opportunities that motivate youth to engage in new life directions by providing new insights, self-realizations, and positive yet realistic views of the future. Service providers indicated the importance of challenging, real-world experiential opportunities that provide youth with disabilities with new insights, self-realizations, and positive yet realistic views of the future. Important experiential opportunities for youth included being away from home, navigating public transportation, directing attendant care, and sharing intense learning and social experiences with peers. The findings provide preliminary qualitative evidence that life skills programs should be

  11. Deteksi Iris Berdasarkan Metode Black Hole dan Circle Curve Fitting

    Directory of Open Access Journals (Sweden)

    Danny Kurnianto

    2013-11-01

    Full Text Available Sistem pengenalan identitas personal berdasarkan ciri biometrika adalah suatu sistem pengenalan seseorang berdasarkan pada ciri biometrika yang melekat pada orang tersebut. Iris mata merupakan salah satu ciri biometrik yang handal untuk sistem pengenalan identitas personal. Bagian sistem pengenalan identitas personal berdasarkan biometrik iris yang dianggap paling krusial adalah deteksi lokasi iris, karena akurasi deteksi iris berpengaruh pada tingkat akurasi sistem secara keseluruhan. Lokasi iris pada citra mata dibatasi oleh dua buah lingkaran yang memisahkan antara bagian iris  dengan pupil dan sklera. Telah banyak metodemetode yang diusulkan oleh para peneliti untuk menghasilkan deteksi lokasi iris dengan akurat dan cepat. Masalah akurasi, kecepatan waktu eksekusi dan ketahanan terhadap noise merupakan bidang penelitian yang menantang pada deteksi iris. Makalah ini menyajikan metode deteksi iris menggunakan metode black hole dan circle curve fitting. Langkah pertama, mencari batas dalam lingkaran iris yang memisahkan antara daerah iris dan pupil. Dengan metode black hole yang bekerja berdasarkan fakta bahwa lokasi pupil merupakan daerah  lingkaran yang paling hitam dan memiliki distribusi nilai intensitas yang seragam, maka lokasi pupil dapat ditentukan dengan teknik pengambangan. Batas lingkaran pupil dapat ditentukan dengan circle curve fitting dari parameter lingkaran daerah pupil. Langkah kedua,  mencari batas luar lingkaran iris yang memisahkan antara iris dan sklera. Peta tepi citra iris dicari dengan menggunakan deteksi tepi Canny, kemudian diambil satu komponen tepi arah vertikal yang dapat mewakili batas lingkaran luar iris. Dari komponen tepi tersebut, dihitung jari-jari iris yang berpusat di pusat pupil. Dengan jari-jari iris dan pusat iris maka dapat ditentukan batas luar iris menggunakan circle curve fitting

  12. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    Science.gov (United States)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  13. The features of teaching methods of programming in the system of supplementary education in informatics and ICT

    Directory of Open Access Journals (Sweden)

    Наталья Геннадьевна Саблукова

    2010-06-01

    Full Text Available The model of formation of the rational contents of teaching to programming in described in the article in view of specificity of supplementary education and features of visual surroundings of programming. The realization of structure of the contents of training to programming is written stage by stage.

  14. Human Iris Recognition System using Wavelet Transform and LVQ

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwan Yong; Lim, Shin Young [Electronics and Telecommunications Research Institute (Korea); Cho, Seong Won [Hongik University (Korea)

    2000-07-01

    The popular methods to check the identity of individuals include passwords and ID cards. These conventional methods for user identification and authentication are not altogether reliable because they can be stolen and forgotten. As an alternative of the existing methods, biometric technology has been paid much attention for the last few decades. In this paper, we propose an efficient system for recognizing the identity of a living person by analyzing iris patterns which have a high level of stability and distinctiveness than other biometric measurements. The proposed system is based on wavelet transform and a competitive neural network with the improved mechanisms. After preprocessing the iris data acquired through a CCD camera, feature vectors are extracted by using Haar wavelet transform. LVQ(Learning Vector Quantization) is exploited to classify these feature vectors. We improve the overall performance of the proposed system by optimizing the size of feature vectors and by introducing an efficient initialization of the weight vectors and a new method for determining the winner in order to increase the recognition accuracy of LVQ. From the experiments, we confirmed that the proposed system has a great potential of being applied to real applications in an efficient and effective way. (author). 14 refs., 13 figs., 7 tabs.

  15. Mission X in Japan, an Education Outreach Program Featuring Astronautical Specialties and Knowledge

    Science.gov (United States)

    Niihori, Maki; Yamada, Shin; Matsuo, Tomoaki; Nakao, Reiko; Nakazawa, Takashi; Kamiyama, Yoshito; Takeoka, Hajime; Matsumoto, Akiko; Ohshima, Hiroshi; Mukai, Chiaki

    In the science field, disseminating new information to the public is becoming increasingly important, since it can aid a deeper understanding of scientific significance and increase the number of future scientists. As part of our activities, we at the Japan Aerospace Exploration Agency (JAXA) Space Biomedical Research Office, started work to focus on education outreach featuring space biomedical research. In 2010, we launched the Mission X education program in Japan, named after “Mission X: Train Like an Astronaut” (hereinafter called “Mission X”), mainly led by NASA and European Space Agency (ESA). Mission X is an international public outreach program designed to encourage proper nutrition and exercise and teaching young people to live and eat like astronauts. We adopted Mission X's standpoint, and modified the program based on the originals to suit Japanese culture and the students' grade. Using astronauts as examples, this mission can motivate and educate students to instill and adopt good nutrition and physical fitness as life-long practices.Here we introduce our pilot mission of the “Mission X in Japan” education program, which was held in early 2011. We are continuing the education/public outreach to promote the public understanding of science and contribute to science education through lectures on astronautical specialties and knowledge.

  16. IRIS (International Research on the Interior of the Sun) Workshop, 2nd, Tashkent, Uzbek SSR, Sept. 1989, Proceedings

    Science.gov (United States)

    Egamberdiev, Sh.; Fossat, Eric

    1991-05-01

    Papers are presented on the IRIS (for International Research on the Interior of the Sun program) sodium cell instrument, the IRIS data management, global oscillation measurements at Kumbel Station in frame of the IRIS program, the Moroccan participation in the study of solar oscillations, and the general presentation of a single IRIS site raw data analysis problem. Attention is given to some peculiarities of the power spectrum of the 5-min solar brightness oscillations, new results on the 160-min pulsation of the sun, 5-min variations of the global magnetic field of the sun, the instrumental capabilities of the Sayan Observatory for the study of oscillatory processes on the sun, and a standard solar model of the asymptotic spectrum of gravity modes as a function of the solar structures. Other papers are on solar convective zone and acoustic oscillations and seismic probing of outer regions of the sun.

  17. Microelectrofluidic iris for variable aperture

    Science.gov (United States)

    Chang, Jong-hyeon; Jung, Kyu-Dong; Lee, Eunsung; Choi, Minseog; Lee, Seungwan

    2012-03-01

    This paper presents a variable aperture design based on the microelectrofluidic technology which integrates electrowetting and microfluidics. The proposed microelectrofluidic iris (MEFI) consists of two immiscible fluids and two connected surface channels formed by three transparent plates and two spacers between them. In the initial state, the confined aqueous ring makes two fluidic interfaces, on which the Laplace pressure is same, in the hydrophobic surface channels. When a certain voltage is applied between the dielectric-coated control electrode beneath the three-phase contact line (TCL) and the reference electrode for grounding the aqueous, the contact angle changes on the activated control electrode. At high voltage over the threshold, the induced positive pressure difference makes the TCLs on the 1st channel advance to the center and the aperture narrow. If there is no potential difference between the control and reference electrodes, the pressure difference becomes negative. It makes the TCLs on the 1st channel recede and the aperture widen to the initial state. It is expected that the proposed MEFI is able to be widely used because of its fast response, circular aperture, digital operation, high aperture ratio, and possibility to be miniaturized for variable aperture.

  18. [The clinical and pathological characteristics of 14 cases of primary iris stromal cysts].

    Science.gov (United States)

    Zhang, Yan; Lin, Jinyong

    2014-10-01

    To analysis the clinical and pathological characteristics of primary iris stromal cyst. Retrospective cases series study. 14 cases of primary iris stromal cyst which were treated in Tianjin Eye Hospital from Jan.1979 to Dec. 2012 were collected. They were all proved by pathological results. Their clinical and pathological features were analyzed. The age of 14 patients were 5 months to 50 years old, the median is 10 years old.10 patients (71.4%) were attacked from children or adolescence, among which onset age of 8 patients were less than 1-year-old. 4 patients (28.6%) occurs when they were adults. 10 cases were female and 4 cases were males. 10 cases were left eyes, 4 cases were right eyes. All cases were unilateral involvement. In these cases, 11 cases appeared as a single translucent or gray-white cystic mass on the iris surface, which 6 cases located in the inferior aspect of the iris, 2 cases appeared with diffused iris cyst and another 1 case's cyst was found occasionally in the eyeball enucleating specimen. 8 cases had corneal opacity or leucoma, 7 cases had secondary glaucoma, and 3 cases had complicated cataract. Pathological features showed: cysts located on the iris surface or in the stroma layer. The cysts of 9 cases were constructed of non-cuticular stratified squamous epithelium cells. 3 cases' cysts were constructed of lens epithelium cells and lens capsular analogical tissues, and the cysts adhesion to the lenstightly. The other 2 cysts were constructed of single or stratified epithelium cells, similar to ciliary epithelium cells. 2 cases complicated with crystalline lens dysplasia, 3 cases complicated with iris tissue dysplasia, 2 cases complicated with ciliary cysts and 1 case had chamber angle dysplasia. Primary iris stoma cyst is rare and it usually occurs in infant, more often in the children less than 1-year-old. Pathological examination showed that most of the cysts originated from the conjunctivaepithelium, minority cysts originated from

  19. New features of the National Cholesterol Education Program Adult Treatment Panel III lipid-lowering guidelines.

    Science.gov (United States)

    Brewer, H Bryan

    2003-04-01

    The National Cholesterol Education Program (NCEP) Adult Treatment Panel III (ATP III) guidelines for lipid-lowering therapy to reduce coronary heart disease (CHD) risk contain a number of features that distinguish them from the previous ATP guidelines. These new features include modifications in lipid/lipoprotein levels considered optimal, abnormal, or reflective of risk; increased focus on primary prevention through use of Framingham risk scoring to define risk in persons with multiple lipid/nonlipid risk factors; and increased focus on the association of the metabolic syndrome with CHD risk. The introduction of the category of CHD risk equivalents-including persons with atherosclerotic disease, diabetes, or 10-year CHD risk > 20% based on Framingham scoring-results in an increase over previous guidelines in the proportion of patients categorized as being at high risk and therefore eligible for more intensive low-density lipoprotein cholesterol (LDL-C)-lowering therapy. Use of the new secondary therapeutic target of non-high-density lipoprotein cholesterol should improve management of lipid risk factors in patients who have elevated triglyceride levels after LDL-C goals have been met. These new features of the NCEP ATP III guidelines should improve identification and treatment of patients with dyslipidemias associated with CHD risk.

  20. Nuottilukihäiriökö ongelma? : oppimishäiriön kohtaaminen soittotunnilla

    OpenAIRE

    Westerlund, Erna

    2010-01-01

    Tämä kirjallinen opinnäytetyö käsittelee nuottilukihäiriötä. Määrittelen nuottilukihäiriön yhdeksi oppimishäiriön muodoksi, sekä rinnastan sen dysleksiaan. Toisessa luvussa pohdin mikä on nuottilukihäiriö. Miten se ilmenee ja miten opettaja voi soitonoppilastaan tarkailemalla ja haastattelemalla pohtia, onko oppilaalla nuottilukihäiriö. Käsittelen myös ilmiön taustalla olevia neurologisia syitä. Kolmannessa ja neljännessä luvussa lähestyn ilmiötä ensin oppilaan ja sitten opettajan näk...

  1. Iris autofluorescence in Fuchs' heterochromic uveitis.

    Science.gov (United States)

    Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li

    2016-10-01

    To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Joo Hyun

    2013-10-01

    Full Text Available We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL. Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery with a toric intraocular lens. This case exhibits clinical manifestations that differ from previously reported trauma of a non-foldable iris-fixated pIOL. A relatively small corneal incision and a large optic diameter of Artiflex pIOLs may prevent posttraumatic total expulsion of intraocular tissues and present different clinical features from the case of non-foldable pIOLs (Artisan. Although the extent of the damage is different, the possibility of aniridia and traumatic cataract exists in eyes with both foldable and non-foldable iris-fixated pIOLs.

  3. Association Between Baseline Iris Thickness and Prophylactic Laser Peripheral Iridotomy Outcomes in Primary Angle Closure Suspects

    Science.gov (United States)

    Lee, Roland Y.; Kasuga, Toshimitsu; Cui, Qi N.; Porco, Travis C.; Huang, Guofu; He, Mingguang; Lin, Shan C.

    2014-01-01

    Objective To evaluate the association between baseline measurements of iris thickness at three positions and change in anterior segment biometric parameters after prophylactic laser peripheral iridotomy (LPI). Design Prospective clinical cohort study. Participants Fifty-two eyes of 52 nonglaucomatous subjects with anatomically narrow angles. Methods Anterior segment optical coherence tomography images captured before and after LPI were analyzed using customized software, the Zhongshan Angle Assessment Program. Differences in preoperative and postoperative measurements for anterior segment biometric parameters were compared by paired Student’s t-tests. Multivariate linear regression models, adjusted for age, sex, ethnicity, and preoperative pupil diameter, were used to examine the association between the baseline measurements of iris thickness at three positions and the change in anterior segment biometric parameters after LPI. Main Outcome Measures Baseline iris thickness measured at 750μm (IT750) and 2000μm (IT2000) from the scleral spur and maximal iris thickness (ITM). Changes in iris curvature (ICURV) and trabecular–iris space area at 500μm (TISA500) and 750μm (TISA750) from the scleral spur after LPI. Results ICURV significantly decreased, while TISA500 and TISA750 significantly increased following LPI (all Piris thickness are associated with greater decrease in ICURV and increases in TISA500 and TISA750 after LPI. This suggests that eyes with thinner irides undergoing LPI were more likely to exhibit greater magnitude of change in terms of flattening of the iris convexity (i.e., ICURV) and widening of the anterior chamber angle (i.e., TISA500 and TISA750). PMID:24534754

  4. ORNL Biometric Eye Model for Iris Recognition

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Barstow, Del R [ORNL; Karakaya, Mahmut [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK); Boehnen, Chris Bensing [ORNL

    2012-01-01

    Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method uses an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.

  5. Association between baseline iris thickness and prophylactic laser peripheral iridotomy outcomes in primary angle-closure suspects.

    Science.gov (United States)

    Lee, Roland Y; Kasuga, Toshimitsu; Cui, Qi N; Porco, Travis C; Huang, Guofu; He, Mingguang; Lin, Shan C

    2014-06-01

    To evaluate the association between baseline measurements of iris thickness at 3 positions and change in anterior segment biometric parameters after prophylactic laser peripheral iridotomy (LPI). Prospective clinical cohort study. Fifty-two eyes of 52 nonglaucomatous subjects with anatomically narrow angles. Anterior segment optical coherence tomography (ASOCT) images captured before and after LPI were analyzed using customized software, the Zhongshan Angle Assessment Program (ZAAP) (Zhongshan Ophthalmic Centre, Guangzhou, China). Differences in preoperative and postoperative measurements for anterior segment biometric parameters were compared by paired Student t tests. Multivariate linear regression models, adjusted for age, sex, ethnicity, and preoperative pupil diameter, were used to examine the association between the baseline measurements of iris thickness at 3 positions and the change in anterior segment biometric parameters after LPI. Baseline iris thickness measured at 750 μm from the scleral spur (IT750), iris thickness measured at 2000 μm from the scleral spur (IT2000), and maximal iris thickness (ITM). Changes in iris curvature (ICURV) and trabecular-iris space area at 500 μm from the scleral spur (TISA500) and 750 μm from the scleral spur (TISA750) after LPI. The ICURV significantly decreased, whereas TISA500 and TISA750 significantly increased after LPI (all P iris thickness are associated with greater decrease in ICURV and increases in TISA500 and TISA750 after LPI. This suggests that eyes with thinner irides undergoing LPI were more likely to exhibit greater magnitude of change in terms of flattening of the iris convexity (i.e., ICURV) and widening of the anterior chamber angle (i.e., TISA500 and TISA750). Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. IRIS Toxicological Review of Decabromodiphenyl Ether (Final Report)

    Science.gov (United States)

    EPA announced the release of the final report, Toxicological Review of Decabromodiphenyl Ether: in support of the Integrated Risk Information System (IRIS). The updated Summary for Decabromodiphenyl Ether and accompanying toxicological review have been added to the IRIS Da...

  7. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing

    Science.gov (United States)

    2011-12-31

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  8. IRIS Toxicological Review of Acrylonitrile (External Review Draft)

    Science.gov (United States)

    [UPDATE] New Schedule for IRIS Acrylonitrile Assessment In May 2012, EPA developed a new schedule for completing the IRIS acrylonitrile assessment. Acrylonitrile is primarily used in the manufacture of acrylic and modacrylic fibers, plastics, and nitrile rubbers. It ...

  9. Internet Renewable energy Information System (IRIS)

    DEFF Research Database (Denmark)

    Bäurle, Britta; Nielsen, Vilhjalmur; Ménard, Lionel

    1999-01-01

    Even though the Internet is now a widely accessible data source, the unorganised flood of information makes a specific request e.g. for renewable energy products inefficient. In addition, existing databases on renewable energies are often old and incomplete. The objective of IRIS has been...... to organise and retrieve renewable energy product information on the Internet instead of collecting it manually. Updating coincides with the self interestself-interest of manufacturers to present their latest renewable energy products on their own HTML documents. IRIS is based on a set of powerful tools...... and intends to find, extract, collect and index HTML documents with standardised META tags that are widely spread across web servers on the Internet. This paper presents the structure of IRIS, the software tools, and gives one example of how to categorise and prepare web-sites with product information...

  10. Programming of adaptive repair process chains using repair features and function blocks

    Directory of Open Access Journals (Sweden)

    Gunter Spöcker

    2016-01-01

    Full Text Available The current trends of product customization and repair of high value parts with individual defects demand automation and a high degree of flexibility of the involved manufacturing process chains. To determine the corresponding requirements this paper gives an overview of manufacturing process chains by distinguishing between horizontal and vertical process chains. The established way of modeling and programming processes with CAx systems and existing approaches is shown. Furthermore, the different types of possible adaptions of a manufacturing process chain are shown and considered as a cascaded control loop. Following this it is discussed which key requirements of repair process chains are unresolved by existing approaches. To overcome the deficits this paper introduces repair features which comprise the idea of geometric features and defines analytical auxiliary geometries based on the measurement input data. This meets challenges normally caused by working directly on reconstructed geometries in the form of triangulated surfaces which are prone to artifacts. Embedded into function blocks, this allows the use of traditional approaches for manufacturing process chains to be applied to adaptive repair process chains.

  11. The Efficacy of IRIS "STAR Legacy" Modules under Different Instructional Conditions

    Science.gov (United States)

    Sayeski, Kristin L.; Hamilton-Jones, Bethany; Oh, Susan

    2015-01-01

    The vast majority of special education teacher preparation programs in the United States incorporate the IRIS Center's "STAR Legacy" modules into their coursework. Given the diversity of module content and ways in which the modules are employed, the purpose of this study was to explore the potential mediating effects of instructional…

  12. IRIS Toxicological Review and Summary Documents for Tertiary Amyl Ethyl Ether (Taee)

    Science.gov (United States)

    This is EPA's first assessment of the noncancer health effects and carcinogenic potential of tertiary amyl ethyl ether (TAEE). The IRIS program is preparing an assessment that will incorporate health effects information available for TAEE, and current risk assessment methods. T...

  13. IRIS Toxicological Review of Hydrogen Cyanide and Cyanide Salts (Final Report)

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Hydrogen Cyanide and Cyanide Salts: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  14. Cataract influence on iris recognition performance

    Science.gov (United States)

    Trokielewicz, Mateusz; Czajka, Adam; Maciejewicz, Piotr

    2014-11-01

    This paper presents the experimental study revealing weaker performance of the automatic iris recognition methods for cataract-affected eyes when compared to healthy eyes. There is little research on the topic, mostly incorporating scarce databases that are often deficient in images representing more than one illness. We built our own database, acquiring 1288 eye images of 37 patients of the Medical University of Warsaw. Those images represent several common ocular diseases, such as cataract, along with less ordinary conditions, such as iris pattern alterations derived from illness or eye trauma. Images were captured in near-infrared light (used in biometrics) and for selected cases also in visible light (used in ophthalmological diagnosis). Since cataract is a disorder that is most populated by samples in the database, in this paper we focus solely on this illness. To assess the extent of the performance deterioration we use three iris recognition methodologies (commercial and academic solutions) to calculate genuine match scores for healthy eyes and those influenced by cataract. Results show a significant degradation in iris recognition reliability manifesting by worsening the genuine scores in all three matchers used in this study (12% of genuine score increase for an academic matcher, up to 175% of genuine score increase obtained for an example commercial matcher). This increase in genuine scores affected the final false non-match rate in two matchers. To our best knowledge this is the only study of such kind that employs more than one iris matcher, and analyzes the iris image segmentation as a potential source of decreased reliability

  15. IRISpy: Analyzing IRIS Data in Python

    Science.gov (United States)

    Ryan, Daniel; Christe, Steven; Mumford, Stuart; Baruah, Ankit; Timothy, Shelbe; Pereira, Tiago; De Pontieu, Bart

    2017-08-01

    IRISpy is a new community-developed open-source software library for analysing IRIS level 2 data. It is written in Python, a free, cross-platform, general-purpose, high-level programming language. A wide array of scientific computing software packages have already been developed in Python, from numerical computation (NumPy, SciPy, etc.), to visualization and plotting (matplotlib), to solar-physics-specific data analysis (SunPy). IRISpy is currently under development as a SunPy-affiliated package which means it depends on the SunPy library, follows similar standards and conventions, and is developed with the support of of the SunPy development team. IRISpy’s has two primary data objects, one for analyzing slit-jaw imager data and another for analyzing spectrograph data. Both objects contain basic slicing, indexing, plotting, and animating functionality to allow users to easily inspect, reduce and analyze the data. As part of this functionality the objects can output SunPy Maps, TimeSeries, Spectra, etc. of relevant data slices for easier inspection and analysis. Work is also ongoing to provide additional data analysis functionality including derivation of systematic measurement errors (e.g. readout noise), exposure time correction, residual wavelength calibration, radiometric calibration, and fine scale pointing corrections. IRISpy’s code base is publicly available through github.com and can be contributed to by anyone. In this poster we demonstrate IRISpy’s functionality and future goals of the project. We also encourage interested users to become involved in further developing IRISpy.

  16. Plateau iris secondary to iridociliary cysts.

    Science.gov (United States)

    Vila-Arteaga, J; Díaz-Céspedes, R A; Suriano, M M

    2015-11-01

    We present a case of plateau iris and glaucoma due to multiple unilateral iridociliary cysts. The patient was treated with iridotomy Nd: YAG laser and 360° iridoplasty, without achieving pressure control. Phacoemulsification improved the hypertension. Dynamic gonioscopy and OCT of the anterior chamber was also performed before and after treatment. Iridociliary cysts are a benign condition that can cause iris plateau configuration, and can produce a difficult to treat ocular hypertension. Cystotomy, peripheral iridoplasty, and other treatments have been proposed. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  17. A modified COMS plaque for iris melanoma

    Directory of Open Access Journals (Sweden)

    Daniel J. Scanderbeg

    2011-09-01

    Full Text Available Melanoma of the iris is a rare condition compared to posterior ocular tumors and in this case report we presenta 51-year-old female patient with diffuse iris melanoma. Traditional COMS (Collaborative Ocular Melanoma Studyplaques are used at our institution for radiation therapy, so a novel modification of the traditional plaque was requiredto allow better conformance with placement on the cornea. The usual silastic insert was machined to dimensions incompliance with the cornea, placed without incident, and treatment delivered with excellent patient tolerance of themodified plaque.

  18. Artificial Neural Networks and Gene Expression Programing based age estimation using facial features

    Directory of Open Access Journals (Sweden)

    Baddrud Z. Laskar

    2015-10-01

    Full Text Available This work is about estimating human age automatically through analysis of facial images. It has got a lot of real-world applications. Due to prompt advances in the fields of machine vision, facial image processing, and computer graphics, automatic age estimation via faces in computer is one of the dominant topics these days. This is due to widespread real-world applications, in areas of biometrics, security, surveillance, control, forensic art, entertainment, online customer management and support, along with cosmetology. As it is difficult to estimate the exact age, this system is to estimate a certain range of ages. Four sets of classifications have been used to differentiate a person’s data into one of the different age groups. The uniqueness about this study is the usage of two technologies i.e., Artificial Neural Networks (ANN and Gene Expression Programing (GEP to estimate the age and then compare the results. New methodologies like Gene Expression Programing (GEP have been explored here and significant results were found. The dataset has been developed to provide more efficient results by superior preprocessing methods. This proposed approach has been developed, tested and trained using both the methods. A public data set was used to test the system, FG-NET. The quality of the proposed system for age estimation using facial features is shown by broad experiments on the available database of FG-NET.

  19. Initial experience with a risk-sharing in vitro fertilization-embryo transfer program with novel features.

    Science.gov (United States)

    Stassart, Jacques P; Bayless, Romaine B; Casey, Colleen L; Phipps, William R

    2011-06-01

    To describe outcomes of the first 100 consecutive infertility patients participating in a risk-sharing program with uncomplicated eligibility requirements. The program included the costs of FSH-containing gonadotropin preparations and provided a full payment refund if no birth occurred that resulted in a normal infant surviving to an age of 1 month. Retrospective cohort study. Private IVF center. Infertility patientsrisk-sharing program with uncomplicated eligibility requirements are very likely to have a successful pregnancy. Other centers may wish to incorporate some of the described program's features into their own risk-sharing IVF programs. Copyright © 2011. Published by Elsevier Inc.

  20. Iris Recognition Method Based on Natural Open Eyes | Latha ...

    African Journals Online (AJOL)

    The non-intrusive property of iris recognition leads to several problems to the images of natural-open eyes and it is hard to increase the accuracy of iris recognition because of these problems. In order to ensure the non-intrusive property as well as achieve an iris recognition which has high accuracy simultaneously, this ...

  1. A patient with multiple iris | Asselman | Southern African Journal of ...

    African Journals Online (AJOL)

    ... initiating ART.1 A case definition for IRIS is shown in Table I. The most common forms of IRIS described occur in association with mycobacterial and herpesvirus infections.3 We describe here a patient who presented with IRIS in association with tuberculosis (TB), then cryptococcosis, and later varicella zoster virus (VZV).

  2. Acute endothelial failure after cosmetic iris implants (NewIris®).

    Science.gov (United States)

    Garcia-Pous, Maria; Udaondo, Patricia; Garcia-Delpech, Salvador; Salom, David; Díaz-Llopis, Manuel

    2011-01-01

    We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.

  3. IRIS - A Community-Based Facility to Support Research in Seismology

    Science.gov (United States)

    Ingate, S.; Ahern, T.; Butler, R.; Fowler, J.; Simpson, D.; Taber, J.; van der Vink, G.

    2002-12-01

    The IRIS Consortium was established in 1984 in response to growing pressure from the research community for enhanced facilities in global and lithospheric seismology. At the same time, the National Science Foundation was encouraging improvements in technology and infrastructure that were sorely needed to ensure the future health of the nation's research endeavors. The governance of IRIS and growth of the facility programs have been guided by strong involvement of the research community. The IRIS management governance and structure serves as an interface between the scientific community, funding agencies, and the programs of IRIS. The structure is designed to focus scientific talent on common objectives, to encourage broad participation, and to efficiently manage its programs. IRIS is governed by a Board of Directors consisting of representatives from each of IRIS' 99 member institutions. Operational policies are set by an Executive Committee elected by the Board of Directors. The Executive Committee, in turn, appoints members to the Planning Committee, the Program Coordination Committee, and the four Standing Committees that provide oversight of the Global Seismographic Network (GSN), the Program of Array Seismic Studies of the Continental Lithosphere (PASSCAL), the Data Management System (DMS), and the Education and Outreach Program (E&O). In addition, special advisory committees and ad hoc working groups are convened for special tasks. Development of the IRIS programs has rested on strong core support from the Instrumentation and Facilities Program of the National Science Foundation's Earth Science Division, augmented with funding from the Department of Defense, Department of Energy, member universities, and private organizations. Close collaboration with the US Geological Survey and other national and foreign institutions has greatly extended the geographical coverage and strengthened the intellectual input that is essential to guiding the evolution of the IRIS

  4. Bemesting van iris in de broeierij

    NARCIS (Netherlands)

    Pasterkamp, H.P.; Marinova, S.; Wees, van N.S.

    2003-01-01

    Bij de bloementeelt van iris komt een aantal afwijkingen voor; vooral bloemverdroging en bladverbranding. Een oplossing hiervoor zou aanpassing van de beschikbaarheid van bepaalde nutriënten zijn. PPO Bloembollen deed onderzoek naar het voorkomen van deze afwijkingen. Vooral de broeiers van irissen

  5. Revealing metabolite biomarkers for acupuncture treatment by linear programming based feature selection.

    Science.gov (United States)

    Wang, Yong; Wu, Qiao-Feng; Chen, Chen; Wu, Ling-Yun; Yan, Xian-Zhong; Yu, Shu-Guang; Zhang, Xiang-Sun; Liang, Fan-Rong

    2012-01-01

    Acupuncture has been practiced in China for thousands of years as part of the Traditional Chinese Medicine (TCM) and has gradually accepted in western countries as an alternative or complementary treatment. However, the underlying mechanism of acupuncture, especially whether there exists any difference between varies acupoints, remains largely unknown, which hinders its widespread use. In this study, we develop a novel Linear Programming based Feature Selection method (LPFS) to understand the mechanism of acupuncture effect, at molecular level, by revealing the metabolite biomarkers for acupuncture treatment. Specifically, we generate and investigate the high-throughput metabolic profiles of acupuncture treatment at several acupoints in human. To select the subsets of metabolites that best characterize the acupuncture effect for each meridian point, an optimization model is proposed to identify biomarkers from high-dimensional metabolic data from case and control samples. Importantly, we use nearest centroid as the prototype to simultaneously minimize the number of selected features and the leave-one-out cross validation error of classifier. We compared the performance of LPFS to several state-of-the-art methods, such as SVM recursive feature elimination (SVM-RFE) and sparse multinomial logistic regression approach (SMLR). We find that our LPFS method tends to reveal a small set of metabolites with small standard deviation and large shifts, which exactly serves our requirement for good biomarker. Biologically, several metabolite biomarkers for acupuncture treatment are revealed and serve as the candidates for further mechanism investigation. Also biomakers derived from five meridian points, Zusanli (ST36), Liangmen (ST21), Juliao (ST3), Yanglingquan (GB34), and Weizhong (BL40), are compared for their similarity and difference, which provide evidence for the specificity of acupoints. Our result demonstrates that metabolic profiling might be a promising method to

  6. Acute endothelial failure after cosmetic iris implants (NewIris®

    Directory of Open Access Journals (Sweden)

    Garcia-Pous M

    2011-05-01

    Full Text Available Maria Garcia-Pous1, Patricia Udaondo2, Salvador Garcia-Delpech2, David Salom1, Manuel Díaz-Llopis21Faculty of Medicine, University of Valencia, Valencia, Spain; 2Ophthalmology Department, Hospital Universitario La Fe, Valencia, SpainAbstract: We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris®. A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.Keywords: NewIris, endothelial failure, cosmetic iris implants

  7. Checking the new IRI model The bottomside B parameters

    CERN Document Server

    Mosert, M; Ezquer, R; Lazo, B; Miro, G

    2002-01-01

    Electron density profiles obtained at Pruhonice (50.0, 15.0), El Arenosillo (37.1, 353.2) and Havana (23, 278) were used to check the bottom-side B parameters BO (thickness parameter) and B1 (shape parameter) predicted by the new IRI - 2000 version. The electron density profiles were derived from ionograms using the ARP technique. The data base includes daytime and nighttime ionograms recorded under different seasonal and solar activity conditions. Comparisons with IRI predictions were also done. The analysis shows that: a) The parameter B1 given by IRI 2000 reproduces better the observed ARP values than the IRI-90 version and b) The observed BO values are in general well reproduced by both IRI versions: IRI-90 and IRI-2000.

  8. [RbcL sequence analysis of Belamcanda chinensis and related medicinal plants of Iris].

    Science.gov (United States)

    Qin, Min-jian; Huang, Yun; Yang, Guang; Xu, Luo-shan; Zhou, Kai-ya

    2003-02-01

    To identify "Shegan" [Belamcanda chinensis (L.) DC.] and relative medicinal plants of Iris including Iris tectorum Maxim., I. dichotoma Pall., I. germanica L. and I. japonica Thunb. by ribulose 1,5-bisphosphate carboxylase Large Gene (rbcL) sequence analysis. General DNA was isolated from the fresh leaves of Belamcanda chinensis and 4 Iris spp. by CTAB. A pair of primers was designed to amplify the rbcL gene and PCR Preps DNA kit was used to purify the PCR products. The rbcL sequences were determined by ABI (Applied Biosystems Inco.) Prism 310 Genetic Analyzer. A fragment of about 750 bp of rbcL gene from Belamcanda chinensis and 4 Iris spp. were amplified and sequenced. The rbcL sequences of Iris tectorum, I. dichotoma Pall. and I. japonica were reported for the first time. The rbcL sequences of 5 species of Iridaceae were aligned and analyzed using Clustal (Version 8.0) and MEGA (Version 2.0.) programs. The nucleotide number of difference is from 1.000 to 20.000. The tranversions is from 0.000 to 9.000 and the transitions is from 0.000 to 14.000. Phylogenetic tree based on rbcL partial sequence data indicated that the eleven samples of 5 species clustered separately. The sequence variation of rbcL can be used to identify Belamcanda chinensis and 4 species of relative medicinal plants of Iris. The molecular phylogenetic tree accords with the classical taxonomy.

  9. Digital compared to screen-film mammography: breast cancer prognostic features in an organized screening program.

    Science.gov (United States)

    Prummel, Maegan V; Done, Susan J; Muradali, Derek; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Shumak, Rene S; Yaffe, Martin J; Holloway, Claire M B; Chiarelli, Anna M

    2014-09-01

    Our previous study found cancer detection rates were equivalent for direct radiography compared to screen-film mammography, while rates for computed radiography were significantly lower. This study compares prognostic features of invasive breast cancers by type of mammography. Approved by the University of Toronto Research Ethics Board, this study identified invasive breast cancers diagnosed among concurrent cohorts of women aged 50-74 screened by direct radiography, computed radiography, or screen-film mammography from January 1, 2008 to December 31, 2009. During the study period, 816,232 mammograms were performed on 668,418 women, and 3,323 invasive breast cancers were diagnosed. Of 2,642 eligible women contacted, 2,041 participated (77.3 %). The final sample size for analysis included 1,405 screen-detected and 418 interval cancers (diagnosed within 24 months of a negative screening mammogram). Polytomous logistic regression was performed to evaluate the association between tumour characteristics and type of mammography, and between tumour characteristics and detection method. Odds ratios (OR) and 95 % confidence intervals (CI) were recorded. Cancers detected by computed radiography compared to screen-film mammography were significantly more likely to be lymph node positive (OR 1.94, 95 %CI 1.01-3.73) and have higher stage (II:I, OR 2.14, 95 %CI 1.11-4.13 and III/IV:I, OR 2.97, 95 %CI 1.02-8.59). Compared to screen-film mammography, significantly more cancers detected by direct radiography (OR 1.64, 95 %CI 1.12-2.38) were lymph node positive. Interval cancers had worse prognostic features compared to screen-detected cancers, irrespective of mammography type. Screening with computed radiography may lead to the detection of cancers with a less favourable stage distribution compared to screen-film mammography that may reflect a delayed diagnosis. Screening programs should re-evaluate their use of computed radiography for breast screening.

  10. Results in Combined Cataract Surgery With Prosthetic Iris Implantation in Patients With Previous Iridocyclectomy for Iris Melanoma.

    Science.gov (United States)

    Snyder, Michael E; Osher, Robert H; Wladecki, Trisha M; Perez, Mauricio A; Augsburger, James J; Corrêa, Zélia

    2017-03-01

    To present visual and functional results following implantation of iris prosthesis combined with cataract surgery in eyes with previous iridocyclectomy for iris melanoma or presumed iris melanoma. Retrospective noncomparative case series. Sixteen patients (16 eyes) with iris defects after iridocyclectomy for iris melanoma in 15 cases and iris adenoma in 1 case underwent prosthetic iris device implantation surgery. Prosthetic iris implantation was combined with phacoemulsification and intraocular lens (IOL) implantation. The visual acuity, subjective glare and photophobia reduction, anatomic outcome, and complications were reviewed. Best-corrected visual acuity was improved in 13 eyes (81.25%), remained stable in 2 eyes (12.25%), and decreased in 1 eye (6.25%). Photophobia and glare improved in every case except for 1 (93.75%). Notably, after surgery 12 patients (75.00%) reported no photophobia and 10 patients (62.50%) reported no glare. The median postoperative follow-up was 29.5 months, with a minimum of 5 months and a maximum of 189 months. All iris devices were in the correct position, and all eyes achieved the desired anatomic result. The IOL optic edges were covered in all areas by either residual iris or opaque portions of a prosthetic iris device. In patients who have undergone previous iridocyclectomy for presumed iris melanoma, combined cataract surgery and iris prosthesis placement, with or without iris reconstruction, can lead to visual improvement as well as reduction of both glare and photophobia. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Transcriptome Profiling of Louisiana iris Root and Identification of Genes Involved in Lead-Stress Response

    Directory of Open Access Journals (Sweden)

    Songqing Tian

    2015-11-01

    Full Text Available Louisiana iris is tolerant to and accumulates the heavy metal lead (Pb. However, there is limited knowledge of the molecular mechanisms behind this feature. We describe the transcriptome of Louisiana iris using Illumina sequencing technology. The root transcriptome of Louisiana iris under control and Pb-stress conditions was sequenced. Overall, 525,498 transcripts representing 313,958 unigenes were assembled using the clean raw reads. Among them, 43,015 unigenes were annotated and their functions classified using the euKaryotic Orthologous Groups (KOG database. They were divided into 25 molecular families. In the Gene Ontology (GO database, 50,174 unigenes were categorized into three GO trees (molecular function, cellular component and biological process. After analysis of differentially expressed genes, some Pb-stress-related genes were selected, including biosynthesis genes of chelating compounds, metal transporters, transcription factors and antioxidant-related genes. This study not only lays a foundation for further studies on differential genes under Pb stress, but also facilitates the molecular breeding of Louisiana iris.

  12. Understanding Legacy Features with Featureous

    DEFF Research Database (Denmark)

    Olszak, Andrzej; Jørgensen, Bo Nørregaard

    2011-01-01

    Feature-centric comprehension of source code is essential during software evolution. However, such comprehension is oftentimes difficult to achieve due the discrepancies between structural and functional units of object-oriented programs. We present a tool for feature-centric analysis of legacy...... Java programs called Featureous that addresses this issue. Featureous allows a programmer to easily establish feature-code traceability links and to analyze their characteristics using a number of visualizations. Featureous is an extension to the NetBeans IDE, and can itself be extended by third...

  13. Nuclear Systems Enhanced Performance Program, Maintenance Cycle Extension in Advanced Light Water Reactor Design

    Energy Technology Data Exchange (ETDEWEB)

    Professor Neill Todreas

    2001-10-01

    A renewed interest in new nuclear power generation in the US has spurred interest in developing advanced reactors with features which will address the public's concerns regarding nuclear generation. However, it is economic performance which will dictate whether any new orders for these plants will materialize. Economic performance is, to a great extent, improved by maximizing the time that the plant is on-line generating electricity relative to the time spent off-line conducting maintenance and refueling. Indeed, the strategy for the advanced light water reactor plant IRIS (International Reactor, Innovative and Secure) is to utilize an eight year operating cycle. This report describes a formalized strategy to address, during the design phase, the maintenance-related barriers to an extended operating cycle. The top-level objective of this investigation was to develop a methodology for injecting component and system maintainability issues into the reactor plant design process to overcome these barriers. A primary goal was to demonstrate the applicability and utility of the methodology in the context of the IRIS design. The first step in meeting the top-level objective was to determine the types of operating cycle length barriers that the IRIS design team is likely to face. Evaluation of previously identified regulatory and investment protection surveillance program barriers preventing a candidate operating PWR from achieving an extended (48 month) cycle was conducted in the context of the IRIS design. From this analysis, 54 known IRIS operating cycle length barriers were identified. The resolution methodology was applied to each of these barriers to generate design solution alternatives for consideration in the IRIS design. The methodology developed has been demonstrated to narrow the design space to feasible design solutions which enable a desired operating cycle length, yet is general enough to have broad applicability. Feedback from the IRIS design team

  14. Multi-task feature selection in microarray data by binary integer programming

    OpenAIRE

    Lan, Liang; Vucetic, Slobodan

    2013-01-01

    A major challenge in microarray classification is that the number of features is typically orders of magnitude larger than the number of examples. In this paper, we propose a novel feature filter algorithm to select the feature subset with maximal discriminative power and minimal redundancy by solving a quadratic objective function with binary integer constraints. To improve the computational efficiency, the binary integer constraints are relaxed and a low-rank approximation to the quadratic ...

  15. Management of aniridia and iris defects: an update on iris prosthesis options.

    Science.gov (United States)

    Weissbart, Sarah B; Ayres, Brandon D

    2016-05-01

    This review examines the advantages and limitations of the various iris prostheses as treatment for aniridia. Multiple prosthetic iris devices have been developed for implantation in eyes with aniridia. However, none is currently approved for use in the USA. Aniridia can be congenital or traumatic in etiology and can lead to glare and other visual disturbances. Treatment options include colored contact lenses, corneal tattooing, and corneal stromal implants, although these carry significant risks of infection and corneal scarring. Prosthetic iris devices can often simultaneously treat aphakia or cataract as well as aniridia, and various models are currently available around the world from Morcher GMBH (Kapuzinerweg 12, 70374 Stuttgart, Germany), Ophtec USA Inc. (6421 Congress Ave Suite 12, Boca Raton, FL 33487, USA) and HumanOptics (Erlangen, Germany). Surgical planning and technique are important in optimizing the safety of these devices. The CustomFlex iris prosthesis from HumanOptics can be implanted within the capsular bag or ciliary sulcus with scleral fixation and offers excellent cosmetic outcomes. At present, the HumanOptics prosthetic iris is being investigated in a multicenter clinical trial.

  16. IRIS PASSCAL Instrument Center: Advancing Portable Seismology

    Science.gov (United States)

    Beaudoin, B. C.; Bilek, S. L.; Anderson, K. R.

    2016-12-01

    IRIS PASSCAL has supported portable seismology for 30 years providing instrumentation and services for nearly 1200 PI-driven experiments. Throughout this time, the scientific community continues to pursue cutting-edge science questions, requiring a steady evolution of IRIS PASSCAL Instrument Center (PIC) services. Deployment strategies and station designs have evolved with the introduction of new technology and from the collective experience of the PI community. New equipment, new power technologies, and extreme environments provide additional challenges. Experiments have also increased in size and complexity, requiring new methods of handling and integrating data. Several recent developments and enhancements to communications hardware, data management, station power, and station design have simplified logistics and increased station reliability. Here we present: advancements in Iridium communications station state-of-health and data transmission; evaluation of battery technologies that simplify station design; software for integrating and storing multimode experiment data; and next generation station designs.

  17. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The draft Toxicological Review of trichloroacetic acid provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  18. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Trichloroacetic Acid (TCA), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. The draft Toxicological Review of Trichloroacetic Acid provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  19. Hyperspectral imaging of the human iris

    Science.gov (United States)

    Di Cecilia, Luca; Marazzi, Francesco; Rovati, Luigi

    2017-07-01

    We describe an optical system and a method for measuring the human iris spectral reflectance in vivo by hyperspectral imaging analysis. It is important to monitor age-related changes in the reflectance properties of the iris as they are a prognostic factor for several eye pathologies. In this paper, we report the outcomes of our most recent research, resulting from the improvement of our imaging system. In particular, a custom tunable light source was developed: the images are now acquired in the spectral range 440 - 900 nm. With this system, we are able to obtain a spectral resolution of 20nm, while each image of 2048 x 1536 pixels has a spatial resolution of 10.7 μm. The results suggest that the instrument could be exploited for measuring iris pigmentation changes over time. These measurements could provide new diagnostic capabilities in ophthalmology. Further studies are required to determine the measurements' repeatability and to develop a spectral library for results evaluation and to detect differences among subsequent screenings of the same subject.

  20. A method of evolving novel feature extraction algorithms for detecting buried objects in FLIR imagery using genetic programming

    Science.gov (United States)

    Paino, A.; Keller, J.; Popescu, M.; Stone, K.

    2014-06-01

    In this paper we present an approach that uses Genetic Programming (GP) to evolve novel feature extraction algorithms for greyscale images. Our motivation is to create an automated method of building new feature extraction algorithms for images that are competitive with commonly used human-engineered features, such as Local Binary Pattern (LBP) and Histogram of Oriented Gradients (HOG). The evolved feature extraction algorithms are functions defined over the image space, and each produces a real-valued feature vector of variable length. Each evolved feature extractor breaks up the given image into a set of cells centered on every pixel, performs evolved operations on each cell, and then combines the results of those operations for every cell using an evolved operator. Using this method, the algorithm is flexible enough to reproduce both LBP and HOG features. The dataset we use to train and test our approach consists of a large number of pre-segmented image "chips" taken from a Forward Looking Infrared Imagery (FLIR) camera mounted on the hood of a moving vehicle. The goal is to classify each image chip as either containing or not containing a buried object. To this end, we define the fitness of a candidate solution as the cross-fold validation accuracy of the features generated by said candidate solution when used in conjunction with a Support Vector Machine (SVM) classifier. In order to validate our approach, we compare the classification accuracy of an SVM trained using our evolved features with the accuracy of an SVM trained using mainstream feature extraction algorithms, including LBP and HOG.

  1. Quantitative analysis of iris changes after physiologic and pharmacologic mydriasis in a rural Chinese population.

    Science.gov (United States)

    Zhang, Ye; Li, Si Zhen; Li, Lei; He, Ming Guang; Thomas, Ravi; Wang, Ning Li

    2014-04-24

    To estimate and compare the change in iris cross-sectional area (IA) and iris volume (IV) following physiologic and pharmacologic pupil dilation in primary angle closure suspects (PACS) and normal subjects. Anterior segment-optical coherence tomography (AS-OCT) measurements in light, dark, and following pharmacologic dilation were obtained on 186 PACS and 224 normal subjects examined during the 5-year follow-up of the Handan Eye Study. Iris cross-sectional area, IV, and other biometric parameters calculated using the Zhongshan angle assessment program in the right eyes of all subjects were analyzed. The mean IA and IV decreased in dark compared with light and after pharmacologic dilation in both PACS and normal eyes. This change was statistically significant in normal eyes: light versus pharmacologic dilation for IA (P = 0.038) and for IV, both light versus dark (P = 0.031) and light versus pharmacologic dilation (P = 0.012). A longer axial length (P = 0.028) and a greater change in pupil diameter (PD) (P iris behavior between PACS and normal rural Chinese subjects following physiologic or pharmacologic pupillary dilation may help provide insights into the pathogenesis of angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. IRIS-2012 OECD/NEA/CSNI benchmark: Numerical simulations of structural impact

    Energy Technology Data Exchange (ETDEWEB)

    Orbovic, Nebojsa, E-mail: nebojsa.orbovic@cnsc-ccsn.gc.ca [Canadian Nuclear Safety Commission, Ottawa, ON (Canada); Tarallo, Francois [IRSN, Fontenay aux Roses (France); Rambach, Jean-Mathieu [Géodynamique et Structures, Bagneux (France); Sagals, Genadijs; Blahoianu, Andrei [Canadian Nuclear Safety Commission, Ottawa, ON (Canada)

    2015-12-15

    A benchmark of numerical simulations related to the missile impact on reinforced concrete (RC) slabs has been launched in the frame of OECD/NEA/CSNI research program “Improving Robustness Assessment Methodologies for Structures Impacted by Missiles”, under the acronym IRIS. The goal of the research program is to simulate RC structural, flexural and punching, behavior under deformable and rigid missile impact. The first phase called IRIS-2010 was a blind prediction of the tests performed at VTT facility in Espoo, Finland. The two simulations were performed related to two series of tests: (1) two tests on the impact of a deformable missile exhibiting damage mainly by flexural (so-called “flexural tests”) or global response and (2) three tests on the impact of a rigid missile exhibiting damage mainly by punching response (so-called “punching tests”) or local response. The simulation results showed significant scatter (coefficient of variation up to 132%) for both flexural and punching cases. The IRIS-2012 is the second, post-test, phase of the benchmark with the goal to improve simulations and reduce the scatter of the results. Based on the IRIS-2010 recommendations and to better calibrate concrete constitutive models, a series of tri-axial tests as well as Brazilian tests were performed as a part of the IRIS-2012 benchmark. 25 teams from 11 countries took part in this exercise. Majority of participants were part of the IRIS-2010 benchmark. Participants showed significant improvement in reducing epistemic uncertainties in impact simulations. Several teams presented both finite element (FE) and simplified analysis as per recommendations of the IRIS-2010. The improvements were at the level of simulation results but also at the level of understanding of impact phenomena and its modeling. Due to the complexity of the physical phenomena and its simulation (high geometric and material non-linear behavior) and inherent epistemic and aleatory uncertainties, the

  3. Key Features of Management of Technology (MoT) Undergraduate Program in Malaysia

    Science.gov (United States)

    Shamsuddin, Alina; Abdullah, Nor Hazana; Wahab, Eta

    2011-01-01

    Management of Technology (MoT) Education is growing both in numbers and importance. There are more than 200 universities in the world that are offering MoT programs. However, these universities have taken different approaches with respect to the names and designs of the programs. In Malaysia, some of the programs are known as Technology…

  4. Sutureless artificial iris after phacoemulsification in congenital aniridia.

    Science.gov (United States)

    Fernández-López, Ester; Pascual, Francisco Pastor; Pérez-López, Marta; Quevedo, Alejandro Madrigal; Martínez, Cristina Peris

    2015-04-01

    This article reports the first case of a sutureless artificial iris prosthesis used in combination with cataract surgery for congenital aniridia with successful visual and cosmetic results. A 15-year-old woman with congenital bilateral partial aniridia, cataracts, and intense photophobia presented to the Cornea and Refractive Surgery Unit of the Ophthalmology Department. She was managed with an artificial iris implant (ArtificialIris, Dr. Schmidt Intraocularlinsen GmbH, Human Optics) fixed in the ciliary sulcus without any sutures after small-incision cataract surgery. At the 1-year follow-up, subjective complaints of glare and photophobia as well as binocular near visual acuity improved significantly. The cosmetic result was excellent. No postoperative complications have been recorded within this period. The ArtificialIris is a promising device for treating photophobia in congenital aniridia. ArtificialIris does not require suture fixation with adequate capsular support and iris remnants.

  5. Exploring the Unique Features of a First Nations Graduate-Level Social Work Program

    Directory of Open Access Journals (Sweden)

    Ralph C. Bodor

    2015-03-01

    Full Text Available Recently, a one-time cohort of graduate-level social work students completed a unique MSW program. The program was delivered in partnership between the Faculty of Social Work, University of Calgary and Blue Quills First Nations College and, of the twenty four graduates; twenty-one were of First Nations or Me´tis ancestry. The program honored traditional knowledge and ways of learning combined with a critical analysis of Western perspectives of social work knowledge. Strong fiscal resources enabled the program to establish a formal support network for the students and to support the development of Indigenous curriculum and programming that encouraged success for the students. The program was fundamentally different than urban on-campus programs while still maintaining graduate level accreditation requirements. This analysis of the program required the use of Indigenous Research Methodology to collect and create an understanding of the program. Instructors commented on the centered, empowered, balanced, and congruent students. The formal and informal, concrete and invisible supports to the students ensured the success of this program and this cohort of students. As one student commented, the program started in ceremony, ended in ceremony, and could not fail within the context ceremony.

  6. HyspIRI Low Latency Concept and Benchmarks

    Science.gov (United States)

    Mandl, Dan

    2010-01-01

    Topics include HyspIRI low latency data ops concept, HyspIRI data flow, ongoing efforts, experiment with Web Coverage Processing Service (WCPS) approach to injecting new algorithms into SensorWeb, low fidelity HyspIRI IPM testbed, compute cloud testbed, open cloud testbed environment, Global Lambda Integrated Facility (GLIF) and OCC collaboration with Starlight, delay tolerant network (DTN) protocol benchmarking, and EO-1 configuration for preliminary DTN prototype.

  7. Bilateral acute iris transillumination (BAIT) initially misdiagnosed as acute iridocyclitis

    OpenAIRE

    Gonul, Saban; Bozkurt, Banu

    2015-01-01

    Bilateral acute iris transillumination (BAIT) is a relatively new clinical entity characterized by bilateral acute loss of iris pigment epithelium, iris transillumination, pigment dispersion in the anterior chamber, and sphincter paralysis. We report the case of a 30-year-old male who was initially diagnosed with acute iridocyclitis in a different clinic and treated with topical and systemic corticosteroids. He was referred to our clinic to seek another opinion because his symptoms did not im...

  8. Embedded Design Research of Iris Information Acquisition System

    OpenAIRE

    Huiyan Xu

    2014-01-01

    In view of the limitation of traditional identification, it is easy to lose and copy keys, cards or ID cards, and it is easy to forget the password, so we designed an embedded application system based on the iris identification technology, which can realize the functions of gathering, inputting, and registering the iris information and identification. The hardware circuit was designed by using advanced RISC machines (ARM) embedded microprocessor as the core. The iris sensor was used to gather...

  9. Acute endothelial failure after cosmetic iris implants (NewIris®)

    OpenAIRE

    Garcia-Pous M; Udaondo P; Garcia-Delpech S; Salom D; Díaz-Llopis M

    2011-01-01

    Maria Garcia-Pous1, Patricia Udaondo2, Salvador Garcia-Delpech2, David Salom1, Manuel Díaz-Llopis21Faculty of Medicine, University of Valencia, Valencia, Spain; 2Ophthalmology Department, Hospital Universitario La Fe, Valencia, SpainAbstract: We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris®. A 21-year-old woman came to us complaining of progressive loss of vision and pain af...

  10. Iris recognition in the presence of ocular disease.

    Science.gov (United States)

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-05-06

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology.

  11. Extending the imaging volume for biometric iris recognition.

    Science.gov (United States)

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  12. Multispectral iris recognition based on group selection and game theory

    Science.gov (United States)

    Ahmad, Foysal; Roy, Kaushik

    2017-05-01

    A commercially available iris recognition system uses only a narrow band of the near infrared spectrum (700-900 nm) while iris images captured in the wide range of 405 nm to 1550 nm offer potential benefits to enhance recognition performance of an iris biometric system. The novelty of this research is that a group selection algorithm based on coalition game theory is explored to select the best patch subsets. In this algorithm, patches are divided into several groups based on their maximum contribution in different groups. Shapley values are used to evaluate the contribution of patches in different groups. Results show that this group selection based iris recognition

  13. New algorithm for iris recognition based on video sequences

    Science.gov (United States)

    Bourennane, Salah; Fossati, Caroline; Ketchantang, William

    2010-07-01

    Among existing biometrics, iris recognition systems are among the most accurate personal biometric identification systems. However, the acquisition of a workable iris image requires strict cooperation of the user; otherwise, the image will be rejected by a verification module because of its poor quality, inducing a high false reject rate (FRR). The FRR may also increase when iris localization fails or when the pupil is too dilated. To improve the existing methods, we propose to use video sequences acquired in real time by a camera. In order to keep the same computational load to identify the iris, we propose a new method to estimate the iris characteristics. First, we propose a new iris texture characterization based on Fourier-Mellin transform, which is less sensitive to pupil dilatations than previous methods. Then, we develop a new iris localization algorithm that is robust to variations of quality (partial occlusions due to eyelids and eyelashes, light reflects, etc.), and finally, we introduce a fast and new criterion of suitable image selection from an iris video sequence for an accurate recognition. The accuracy of each step of the algorithm in the whole proposed recognition process is tested and evaluated using our own iris video database and several public image databases, such as CASIA, UBIRIS, and BATH.

  14. Gabor Weber Local Descriptor for Bovine Iris Recognition

    Directory of Open Access Journals (Sweden)

    Shengnan Sun

    2013-01-01

    Full Text Available Iris recognition is a robust biometric technology. This paper proposes a novel local descriptor for bovine iris recognition, named Gabor Weber local descriptor (GWLD. We first compute the Gabor magnitude maps for the input bovine iris image, and then calculate the differential excitation and orientation for each pixel over each Gabor magnitude map. After that, we use these differential excitations and orientations to construct the GWLD histogram representation. Finally, histogram intersection is adopted to measure the similarity between different GWLD histograms. The experimental results on the SEU bovine iris database verify the representation power of our proposed local descriptor.

  15. Discriminant Feature Selection by Genetic Programming: Towards a domain independent multi-class object detection system.

    Directory of Open Access Journals (Sweden)

    Jacques-André Landry

    2005-02-01

    Full Text Available In order to implement a multi-class object detection system, an efficient object representation is needed; in this short paper, we present a feature selection method based on the Genetic Algorithm paradigm. This method allows for the identification of a set of features that best represent the classes in the problem at hand. The idea would then be to have a broad set of features to describe any object, and then to use the presented feature selection method to adapt the description to the actual needs of the classification problem. Furthermore, the tree like solutions generated by the method can be interpreted and modified for increased generality. A brief review of literature, the first implementation of the method and the first results are presented here. The method shows potential to be used as a building block of a detection system, although further experimentation is underway in order to fully asses the power of the method.

  16. Intraoperative floppy iris syndrome (IFIS): a practical approach to medical and surgical considerations in cataract extractions

    DEFF Research Database (Denmark)

    Storr-Paulsen, Allan; Nørregaard, Jens Christian; Børme, Kim Kamp

    2009-01-01

    Abstract. Intraoperative floppy iris syndrome (IFIS) during cataract surgery is characterized by iris fluttering, iris prolapse towards the incisions, and a progressive pupillary constriction leading to high rates of complications. The syndrome has been reported following the treatment of benign...

  17. Facilitate, Collaborate, Educate: the Role of the IRIS Consortium in Supporting National and International Research in Seismology (Invited)

    Science.gov (United States)

    Simpson, D. W.; Beck, S. L.

    2009-12-01

    Over the twenty-five years since its founding in 1984, the IRIS Consortium has contributed in fundamental ways to change the practice and culture of research in seismology in the US and worldwide. From an original founding group of twenty-two U.S. academic institutions, IRIS membership has now grown to 114 U.S. Member Institutions, 20 Educational Affiliates and 103 Foreign Affiliates. With strong support from the National Science Foundation, additional resources provided by other federal agencies, close collaboration with the U.S. Geological Survey and many international partners, the technical resources of the core IRIS programs - the Global Seismographic Network (GSN), the Program for Array Seismic Studies of the Continental Lithosphere (PASSCAL), the Data Management System (DMS) and Education and Outreach - have grown to become a major national and international source of experimental data for research on earthquakes and Earth structure, and a resource to support education and outreach to the public. While the primary operational focus of the Consortium is to develop and maintain facilities for the collection of seismological data for basic research, IRIS has become much more than an instrument facility. It has become a stimulus for collaboration between academic seismological programs and a focus for their interactions with national and international partners. It has helped establish the academic community as a significant contributor to the collection of data and an active participant in global research and monitoring. As a consortium of virtually all of the Earth science research institutions in the US, IRIS has helped coordinate the academic community in the development of new initiatives, such as EarthScope, to strengthen the support for science and argue for the relevance of seismology and its use in hazard mitigation. The early IRIS pioneers had the foresight to carefully define program goals and technical standards for the IRIS facilities that have stood

  18. Automated identification of protein-ligand interaction features using Inductive Logic Programming: a hexose binding case study

    Directory of Open Access Journals (Sweden)

    A Santos Jose C

    2012-07-01

    Full Text Available Abstract Background There is a need for automated methods to learn general features of the interactions of a ligand class with its diverse set of protein receptors. An appropriate machine learning approach is Inductive Logic Programming (ILP, which automatically generates comprehensible rules in addition to prediction. The development of ILP systems which can learn rules of the complexity required for studies on protein structure remains a challenge. In this work we use a new ILP system, ProGolem, and demonstrate its performance on learning features of hexose-protein interactions. Results The rules induced by ProGolem detect interactions mediated by aromatics and by planar-polar residues, in addition to less common features such as the aromatic sandwich. The rules also reveal a previously unreported dependency for residues cys and leu. They also specify interactions involving aromatic and hydrogen bonding residues. This paper shows that Inductive Logic Programming implemented in ProGolem can derive rules giving structural features of protein/ligand interactions. Several of these rules are consistent with descriptions in the literature. Conclusions In addition to confirming literature results, ProGolem’s model has a 10-fold cross-validated predictive accuracy that is superior, at the 95% confidence level, to another ILP system previously used to study protein/hexose interactions and is comparable with state-of-the-art statistical learners.

  19. Frontal view reconstruction for iris recognition

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J; Bolme, David S; Boehnen, Chris Bensing

    2015-02-17

    Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

  20. IRIS Toxicological Review of Acrylamide (External Review ...

    Science.gov (United States)

    EPA has conducted a peer review by EPA’s Science Advisory Board (SAB) of the scientific basis supporting the human health hazard and dose-response assessment of acrylamide that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that the science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. The draft Toxicological Review of Acrylamide provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to a chronic exposure to acrylamide.

  1. DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SGI IRIS VERSION)

    Science.gov (United States)

    Rogers, J. L.

    1994-01-01

    amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the

  2. Utilisation of Perkin-Elmer Operating System Features to Optimise Programming Efficiency

    OpenAIRE

    Gray, L.S.; Morris, A.S.

    1982-01-01

    This paper consists of printed notes given as the first lecture of a two-part special lecture course on efficient programming. Emphasis is laid on on efficient programming in relation to the hardware and operating system of the Perkin-Elmer 3220 computer, although the principles embodied are in general, universally applicable. The functioning of the operating system and its interaction with the hardware of the computer is explained in considerable detail, as this is felt a necessary prerequis...

  3. The Identification, Implementation, and Evaluation of Critical User Interface Design Features of Computer-Assisted Instruction Programs in Mathematics for Students with Learning Disabilities

    Science.gov (United States)

    Seo, You-Jin; Woo, Honguk

    2010-01-01

    Critical user interface design features of computer-assisted instruction programs in mathematics for students with learning disabilities and corresponding implementation guidelines were identified in this study. Based on the identified features and guidelines, a multimedia computer-assisted instruction program, "Math Explorer", which delivers…

  4. Unconstrained Iris Acquisition and Recognition Using COTS PTZ Camera

    Directory of Open Access Journals (Sweden)

    Venugopalan Shreyas

    2010-01-01

    Full Text Available Abstract Uniqueness of iris patterns among individuals has resulted in the ubiquity of iris recognition systems in virtual and physical spaces, at high security facilities around the globe. Traditional methods of acquiring iris patterns in commercial systems scan the iris when an individual is at a predetermined location in front of the scanner. Most state-of-the-art techniques for unconstrained iris acquisition in literature use expensive custom equipment and are composed of a multicamera setup, which is bulky, expensive, and requires calibration. This paper investigates a method of unconstrained iris acquisition and recognition using a single commercial off-the-shelf (COTS pan-tilt-zoom (PTZ camera, that is compact and that reduces the cost of the final system, compared to other proposed hierarchical multicomponent systems. We employ state-of-the-art techniques for face detection and a robust eye detection scheme using active shape models for accurate landmark localization. Additionally, our system alleviates the need for any calibration stage prior to its use. We present results using a database of iris images captured using our system, while operating in an unconstrained acquisition mode at 1.5 m standoff, yielding an iris diameter in the 150–200 pixels range.

  5. Delay of Iris flower senescence by cytokinins and jasmonates

    NARCIS (Netherlands)

    Doorn, van W.G.; Celikel, F.G.; Pak, C.; Harkema, H.

    2013-01-01

    It is not known whether tepal senescence in Iris flowers is regulated by hormones. We applied hormones and hormone inhibitors to cut flowers and isolated tepals of Iris x hollandica cv. Blue Magic. Treatments with ethylene or ethylene antagonists indicated lack of ethylene involvement. Auxins or

  6. Investigation on Optimization in Segmentation Phase of Iris Recognition

    Directory of Open Access Journals (Sweden)

    Selvamuthukumaran Shanmugam

    2010-01-01

    Full Text Available In a progressively more digital society, the demandfor secure identification has led to amplified development ofbiometric systems. Iris biometric systems are becoming widelyadopted and accepted as one of the most effective ways topositively identify people. In this paper, the Segmentation phasesof Iris recognition has been examined. The performance of theSegmentation phase could be amplified by the proposedoptimization technique- Optimized Iris Segmentation using SobelEdge Detection. By the proposed method, the overall rank-onerecognition rate of 90% is being achieved which is much betterthan reported accuracies for iris recognition in the literature.Also the proposed approach makes the overall iris recognitionsystem performance by the improvement factor of 10 fold as well.

  7. A NEURAL NETWORK BASED IRIS RECOGNITION SYSTEM FOR PERSONAL IDENTIFICATION

    Directory of Open Access Journals (Sweden)

    Usham Dias

    2010-10-01

    Full Text Available This paper presents biometric personal identification based on iris recognition using artificial neural networks. Personal identification system consists of localization of the iris region, normalization, enhancement and then iris pattern recognition using neural network. In this paper, through results obtained, we have shown that a person’s left and right eye are unique. In this paper, we also show that the network is sensitive to the initial weights and that over-training gives bad results. We also propose a fast algorithm for the localization of the inner and outer boundaries of the iris region. Results of simulations illustrate the effectiveness of the neural system in personal identification. Finally a hardware iris recognition model is proposed and implementation aspects are discussed.

  8. Immunohistochemical evidence of specific iris involvement in Blau syndrome.

    Science.gov (United States)

    Paparizos, Stella C; Goldstein, Debra A; Bouhenni, Rachida A; Steiner, Scott; Dunmire, Jeffrey J; Edward, Deepak P

    2012-12-01

    To evaluate iris involvement in Blau syndrome using histology and immunohistochemistry. Iridectomy specimen of a patient with treated Blau syndrome and a normal control were evaluated by light microscopy and immunohistochemistry using antibodies against CD4(+), CD8(+), HLA-DR, CD68(+), NF-κB and IL-17. Blau iris tissue demonstrated increased numbers of CD4(+) lymphocytes and CD68 negative, HLA-DR positive spindle shaped cells compared to normal iris tissue. Blau iris tissue also demonstrated elevated CD4(+)/CD8(+) ratio and IL-17 and NF-κB immunolabeling. No macrophages, epithelioid cells, or granulomas were noted in the Blau specimen. The persistent immunolocalization of inflammatory markers in an iris specimen from an aggresively treated patient with proven Blau syndrome suggests that further pathologic and immunohistochemical investigation of Blau ocular tissue is necessary to better understand the complexities of NOD2 activating mutations in the eye.

  9. Bilateral acute iris transillumination following systemic administration of antibiotics.

    Science.gov (United States)

    Tranos, Paris; Lokovitis, Evangelos; Masselos, Stelios; Kozeis, Nikolaos; Triantafylla, Magda; Markomichelakis, Nikolaos

    2018-03-02

    To describe the demographic characteristics, clinical features, and potential prognostic factors of bilateral acute iris transillumination (BAIT) following oral antibiotic uptake. A retrospective study of 16 consecutive patients who developed BAIT following treatment with systemic antibiotics. Detailed past medical and ocular history was obtained, presenting signs and symptoms were documented and demographic characteristics were analyzed. All patients underwent a complete ocular examination and laboratory investigation. The course of best corrected visual acuity (BCVA), anterior chamber activity, and intraocular pressure (IOP) during the follow-up period were recorded and possible correlations with potential prognosticators were investigated. Fourteen females and two males were included in the present study. The mean age (SD) of the patients was 43 (14) years. All individuals presented conjunctival injection and photophobia and developed bilateral transillumination defects, fixed mid-dilated pupils and pigment dispersion in the anterior chamber. Systemic antibiotics were previously prescribed in all cases (13 patients with moxifloxacin and three patients with clarithromycin) and the mean (SD) interval between onset of symptoms and antibiotic administration was 17 (4) days. Ocular hypertension complicated all eyes and required antiglaucoma medication in 25 eyes. Severe anterior chamber pigment dispersion and higher IOP during the first week after presentation was significantly associated with longer duration of ocular hypertension (OHT) (p = 0.019). BAIT represents a rare clinical entity with characteristic features. Although etiopathogenesis of this condition remains unclear, a series of cases that indicate a strong correlation between systemic antibiotic administration and BAIT is herein presented.

  10. Feasibility study neutron diffraction at IRI

    Energy Technology Data Exchange (ETDEWEB)

    Haan, V.O. de

    1995-06-01

    Although neutron diffraction is a basic and relatively simple technique and should be available at a neutron source, it is not possible to perform neutron diffraction measurements at IRI at this moment. Until recently a neutron diffractometer with a relatively small flux at the sample position and a relaxed resolution (designed for liquid diffraction) was operated at IRI. Due to the modest neutron source intensity and the relatively old design (flat monochromator and single detector) this diffractometer was outdated. However, at a contemporary reactor source an instrument to perform neutron diffraction experiments cannot be missed. This study shows that thanks to recent developments in neutron diffraction optics it is possible to increase the flux, to enhance the resolution and to get a better flexibility. If also the number of detectors is increased or a position-sensitive detector is used to performance can be increased at least a thousand fold. A preliminary design is given to indicate how this gain can be realized. (orig.).

  11. Making automated computer program documentation a feature of total system design

    Science.gov (United States)

    Wolf, A. W.

    1970-01-01

    It is pointed out that in large-scale computer software systems, program documents are too often fraught with errors, out of date, poorly written, and sometimes nonexistent in whole or in part. The means are described by which many of these typical system documentation problems were overcome in a large and dynamic software project. A systems approach was employed which encompassed such items as: (1) configuration management; (2) standards and conventions; (3) collection of program information into central data banks; (4) interaction among executive, compiler, central data banks, and configuration management; and (5) automatic documentation. A complete description of the overall system is given.

  12. Program of Adaptation Assistance in Foster Families and Particular Features of Its Implementation

    Science.gov (United States)

    Zakirova, Venera G.; Gaysina, Guzel I.; Zhumabaeva, Asia

    2015-01-01

    Relevance of the problem stated in the article, conditioned by the fact that the successful adaptation of orphans in a foster family requires specialized knowledge and skills, as well as the need of professional support. Therefore, this article aims at substantiation of the effectiveness of the developed pilot program psycho-pedagogical support of…

  13. Edge detection of iris of the eye for human biometric identification system

    Directory of Open Access Journals (Sweden)

    Kateryna O. Tryfonova

    2015-03-01

    Full Text Available Method of human biometric identification by iris of the eye is considered as one of the most accurate and reliable methods of identification. Aim of the research is to solve the problem of edge detection of digital image of the human eye iris to be able to implement human biometric identification system by means of mobile device. To achieve this aim the algorithm of edge detection by Canny is considered in work. It consists of the following steps: smoothing, finding gradients, non-maximum suppression, double thresholding with hysteresis. The software implementation of the Canny algorithm is carried out for the Android mobile platform with the use of high level programming language Java.

  14. Efficient Iris Recognition Based on Optimal Subfeature Selection and Weighted Subregion Fusion

    Directory of Open Access Journals (Sweden)

    Ying Chen

    2014-01-01

    Full Text Available In this paper, we propose three discriminative feature selection strategies and weighted subregion matching method to improve the performance of iris recognition system. Firstly, we introduce the process of feature extraction and representation based on scale invariant feature transformation (SIFT in detail. Secondly, three strategies are described, which are orientation probability distribution function (OPDF based strategy to delete some redundant feature keypoints, magnitude probability distribution function (MPDF based strategy to reduce dimensionality of feature element, and compounded strategy combined OPDF and MPDF to further select optimal subfeature. Thirdly, to make matching more effective, this paper proposes a novel matching method based on weighted sub-region matching fusion. Particle swarm optimization is utilized to accelerate achieve different sub-region’s weights and then weighted different subregions’ matching scores to generate the final decision. The experimental results, on three public and renowned iris databases (CASIA-V3 Interval, Lamp, andMMU-V1, demonstrate that our proposed methods outperform some of the existing methods in terms of correct recognition rate, equal error rate, and computation complexity.

  15. Enhancement of Iris Recognition System Based on Phase Only Correlation

    Directory of Open Access Journals (Sweden)

    Nuriza Pramita

    2011-08-01

    Full Text Available Iris recognition system is one of biometric based recognition/identification systems. Numerous techniques have been implemented to achieve a good recognition rate, including the ones based on Phase Only Correlation (POC. Significant and higher correlation peaks suggest that the system recognizes iris images of the same subject (person, while lower and unsignificant peaks correspond to recognition of those of difference subjects. Current POC methods have not investigated minimum iris point that can be used to achieve higher correlation peaks. This paper proposed a method that used only one-fourth of full normalized iris size to achieve higher (or at least the same recognition rate. Simulation on CASIA version 1.0 iris image database showed that averaged recognition rate of the proposed method achieved 67%, higher than that of using one-half (56% and full (53% iris point. Furthermore, all (100% POC peak values of the proposed method was higher than that of the method with full iris points.

  16. A simple shape prior model for iris image segmentation

    Science.gov (United States)

    Bishop, Daniel A.; Yezzi, Anthony, Jr.

    2011-06-01

    In order to make biometric systems faster and more user-friendly, lower-quality images must be accepted. A major hurdle in this task is accurate segmentation of the boundaries of the iris in these images. Quite commonly, circle-fitting is used to approximate the boundaries of the inner (pupil) and outer (limbic) boundaries of the iris, but this assumption does not hold for off-axis or otherwise non-circular boundaries. In this paper we present a novel, foundational method for elliptical segmentation of off-axis iris images. This method uses active contours with constrained flow to achieve a simplified form of shape prior active contours. This is done by calculating a region-based contour evolution and projecting it upon a properly chosen set of vectors to confine it to a class of shapes. In this case, that class of shapes is ellipses. This serves to regularize the contour, simplifying the curve evolution and preventing the development of irregularities that present challenges in iris segmentation. The proposed method is tested using images from the UBIRIS v.1 and CASIA-IrisV3 image data sets, with both near-ideal and off-axis images. Additional testing has been performed using the WVU Off Axis/Angle Iris Dataset, Release 1. By avoiding many of the assumptions commonly used in iris segmentation methods, the proposed method is able to accurately fit elliptical boundaries to off-axis images.

  17. Evaluating the impact of image preprocessing on iris segmentation

    Directory of Open Access Journals (Sweden)

    José F. Valencia-Murillo

    2014-08-01

    Full Text Available Segmentation is one of the most important stages in iris recognition systems. In this paper, image preprocessing algorithms are applied in order to evaluate their impact on successful iris segmentation. The preprocessing algorithms are based on histogram adjustment, Gaussian filters and suppression of specular reflections in human eye images. The segmentation method introduced by Masek is applied on 199 images acquired under unconstrained conditions, belonging to the CASIA-irisV3 database, before and after applying the preprocessing algorithms. Then, the impact of image preprocessing algorithms on the percentage of successful iris segmentation is evaluated by means of a visual inspection of images in order to determine if circumferences of iris and pupil were detected correctly. An increase from 59% to 73% in percentage of successful iris segmentation is obtained with an algorithm that combine elimination of specular reflections, followed by the implementation of a Gaussian filter having a 5x5 kernel. The results highlight the importance of a preprocessing stage as a previous step in order to improve the performance during the edge detection and iris segmentation processes.

  18. Efficient quantitative assessment of facial paralysis using iris segmentation and active contour-based key points detection with hybrid classifier.

    Science.gov (United States)

    Barbosa, Jocelyn; Lee, Kyubum; Lee, Sunwon; Lodhi, Bilal; Cho, Jae-Gu; Seo, Woo-Keun; Kang, Jaewoo

    2016-03-12

    Facial palsy or paralysis (FP) is a symptom that loses voluntary muscles movement in one side of the human face, which could be very devastating in the part of the patients. Traditional methods are solely dependent to clinician's judgment and therefore time consuming and subjective in nature. Hence, a quantitative assessment system becomes apparently invaluable for physicians to begin the rehabilitation process; and to produce a reliable and robust method is challenging and still underway. We introduce a novel approach for a quantitative assessment of facial paralysis that tackles classification problem for FP type and degree of severity. Specifically, a novel method of quantitative assessment is presented: an algorithm that extracts the human iris and detects facial landmarks; and a hybrid approach combining the rule-based and machine learning algorithm to analyze and prognosticate facial paralysis using the captured images. A method combining the optimized Daugman's algorithm and Localized Active Contour (LAC) model is proposed to efficiently extract the iris and facial landmark or key points. To improve the performance of LAC, appropriate parameters of initial evolving curve for facial features' segmentation are automatically selected. The symmetry score is measured by the ratio between features extracted from the two sides of the face. Hybrid classifiers (i.e. rule-based with regularized logistic regression) were employed for discriminating healthy and unhealthy subjects, FP type classification, and for facial paralysis grading based on House-Brackmann (H-B) scale. Quantitative analysis was performed to evaluate the performance of the proposed approach. Experiments show that the proposed method demonstrates its efficiency. Facial movement feature extraction on facial images based on iris segmentation and LAC-based key point detection along with a hybrid classifier provides a more efficient way of addressing classification problem on facial palsy type and degree

  19. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    Science.gov (United States)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A.; Bustamante, John G.; Kirkconnell, Carl S.; Luong, Thomas T.; Murphy, J. B.; Haley, Michael F.

    2014-01-01

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

  20. PROPERTIES OF CHROMOSPHERIC EVAPORATION AND PLASMA DYNAMICS OF A SOLAR FLARE FROM IRIS OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Sadykov, Viacheslav M.; Dominguez, Santiago Vargas; Kosovichev, Alexander G. [Big Bear Solar Observatory, New Jersey Institute of Technology, Big Bear City, CA 92314 (United States); Sharykin, Ivan N.; Struminsky, Alexei B.; Zimovets, Ivan [Space Research Institute (IKI) of Russian Academy of Sciences, Moscow 117997 (Russian Federation)

    2015-06-01

    The dynamics of hot chromospheric plasma of solar flares is a key to understanding the mechanisms of flare energy release and particle acceleration. A moderate M1.0 class flare of 2014 June 12, (SOL2014-06-12T21:12) was simultaneously observed by NASA's Interface Region Imaging Spectrograph (IRIS) and other spacecraft, and also by the New Solar Telescope at the BBSO. This paper presents the first part of our investigation focused on analysis of the IRIS data. Our analysis of the IRIS data in different spectral lines reveals a strong redshifted jet-like flow with a speed of ∼100 km s{sup −1} of the chromospheric material before the flare. Strong nonthermal emission of the C ii k 1334.5 Å line, formed in the chromosphere–corona transition region, is observed at the beginning of the impulsive phase in several small (with a size of ∼1″) points. It is also found that the C ii k line is redshifted across the flaring region before, during, and after the impulsive phase. A peak of integrated emission of the hot (1.1 · 10{sup 7} K) plasma in the Fe xxi 1354.1 Å line is detected approximately five minutes after the integrated emission peak of the lower temperature C ii k. A strong blueshift of the Fe xxi line across the flaring region corresponds to evaporation flows of the hot chromospheric plasma with a speed of 50 km s{sup −1}. Additional analysis of the RHESSI data supports the idea that the upper chromospheric dynamics observed by IRIS has features of “gentle” evaporation driven by heating of the solar chromosphere by accelerated electrons and by a heat flux from the flare energy release site.

  1. Neovascularization of the iris in retinoschisis.

    Science.gov (United States)

    Slean, Geraldine R; Fu, Arthur D; Chen, Judy; Kalevar, Ananda

    2017-09-01

    To report the association of rubeosis iridis with chronic bullous degenerative peripheral retinoschisis. A 63-year-old female presented with acute hyphema and neovascularization of the iris in association with elevated intraocular pressure. Posterior segment examination including imaging revealed no vascular occlusion as a potential cause. However, large, peripheral bullous retinoschisis was noted in the right eye. No nonperfusion aside from that seen within the schism detachment, or neovascularization of the retina on wide-field fundus photography or fluorescein angiography was noted. Bullous retinoschisis was also found in the left eye. The patient was treated conservatively with prednisolone acetate and timolol eye drops. Chronic bullous retinoschisis can be associated with anterior segment neovascularization such as rubeosis iridis, presumably due to non-perfusion within the retinoschisis cavity.

  2. Iris segmentation using an edge detector based on fuzzy sets theory and cellular learning automata.

    Science.gov (United States)

    Ghanizadeh, Afshin; Abarghouei, Amir Atapour; Sinaie, Saman; Saad, Puteh; Shamsuddin, Siti Mariyam

    2011-07-01

    Iris-based biometric systems identify individuals based on the characteristics of their iris, since they are proven to remain unique for a long time. An iris recognition system includes four phases, the most important of which is preprocessing in which the iris segmentation is performed. The accuracy of an iris biometric system critically depends on the segmentation system. In this paper, an iris segmentation system using edge detection techniques and Hough transforms is presented. The newly proposed edge detection system enhances the performance of the segmentation in a way that it performs much more efficiently than the other conventional iris segmentation methods.

  3. BRCA1-IRIS overexpression promotes formation of aggressive breast cancers.

    Directory of Open Access Journals (Sweden)

    Yoshiko Shimizu

    Full Text Available INTRODUCTION: Women with HER2(+ or triple negative/basal-like (TN/BL breast cancers succumb to their cancer rapidly due, in part to acquired Herceptin resistance and lack of TN/BL-targeted therapies. BRCA1-IRIS is a recently discovered, 1399 residue, BRCA1 locus alternative product, which while sharing 1365 residues with the full-length product of this tumor suppressor gene, BRCA1/p220, it has oncoprotein-like properties. Here, we examine whether BRCA1-IRIS is a valuable treatment target for HER2(+ and/or TN/BL tumors. METHODOLOGY/PRINCIPAL FINDINGS: Immunohistochemical staining of large cohort of human breast tumor samples using new monoclonal anti-BRCA1-IRIS antibody, followed by correlation of BRCA1-IRIS expression with that of AKT1, AKT2, p-AKT, survivin and BRCA1/p220, tumor status and age at diagnosis. Generation of subcutaneous tumors in SCID mice using human mammary epithelial (HME cells overexpressing TERT/LT/BRCA1-IRIS, followed by comparing AKT, survivin, and BRCA1/p220 expression, tumor status and aggressiveness in these tumors to that in tumors developed using TERT/LT/Ras(V12-overexpressing HME cells. Induction of primary and invasive rat mammary tumors using the carcinogen N-methyl-N-nitrosourea (NMU, followed by analysis of rat BRCA1-IRIS and ERα mRNA levels in these tumors. High BRCA1-IRIS expression was detected in the majority of human breast tumors analyzed, which was positively correlated with that of AKT1-, AKT2-, p-AKT-, survivin, but negatively with BRCA1/p220 expression. BRCA1-IRIS-positivity induced high-grade, early onset and metastatic HER2(+ or TN/BL tumors. TERT/LT/BRCA1-IRIS overexpressing HME cells formed invasive subcutaneous tumors that express high AKT1, AKT2, p-AKT and vimentin, but no CK19, p63 or BRCA1/p220. NMU-induced primary and invasive rat breast cancers expressed high levels of rat BRCA1-IRIS mRNA but low levels of rat ERα mRNA. CONCLUSION/SIGNIFICANCE: BRCA1-IRIS overexpression triggers aggressive

  4. Methylene blue-related corneal edema and iris discoloration.

    Science.gov (United States)

    Timucin, Ozgur Bulent; Karadag, Mehmet Fatih; Aslanci, Mehmet Emin; Baykara, Mehmet

    2016-04-01

    We report the case of a 70-year-old female patient who developed corneal edema and iris discoloration following the inadvertent use of 1% methylene blue instead of 0.025% trypan blue to stain the anterior capsule during cataract phacoemulsification surgery. Copious irrigation was performed upon realization of incorrect dye use. Corneal edema and iris discoloration developed during the early postoperative period and persisted at 24-months follow-up. However, keratoplasty was not required. The intracameral use of 1% methylene blue has a cytotoxic effect on the corneal endothelium and iris epithelium. Copious irrigation for at least 30 min using an anterior chamber maintainer may improve outcomes.

  5. A Design Case Featuring the Graduate Design Studio at Indiana University Bloomington’s Human-Computer Interaction Design Program

    Directory of Open Access Journals (Sweden)

    Matthew Callison

    2011-01-01

    Full Text Available In this article the author illustrates the design of a physical space that was created to serve as a performance intervention for graduate students in the Human-Computer Interaction Design (HCId program in the School of Informatics, Indiana University Bloomington. Opened in Fall 2010, the HCId Graduate Design Studio was designed to help facilitate collaboration between students and faculty in the HCId Program. An effort was made to document the Studio and students working in the Studio over an extended period of time. The author visited the Design Studio a minimum of ten times between late January and late April 2011. Visits were conducted on different days of the week (Monday - Friday and at different times of the day to capture a variety of students and activity level in the Studio. In order to gain a perspective on the two distinct groups of students who utilize the Studio, interviews of graduate students from both the HCId Master of Science and Doctoral program were conducted. In addition interviews were conducted of two other important stakeholders, the HCId Program Director and the Director of Facilities for the School of Informatics, both of whom were heavily involved in the design of the Studio. Through faculty and student interviews, text descriptions, photographs, and audio and video recordings this article addresses the design features and their impact, both successful and unsuccessful, on student and faculty collaboration of the HCId Graduate Design Studio.

  6. The radiology of IRIS (immune reconstitution inflammatory syndrome) in patients with mycobacterial tuberculosis and HIV co-infection: appearances in 11 patients

    Energy Technology Data Exchange (ETDEWEB)

    Rajeswaran, G. [Department of Radiology and Department of HIV/GU Medicine, Chelsea and Westminster Hospital, London (United Kingdom)]. E-mail: grajeswaran@hotmail.com; Becker, J.L. [Department of Radiology and Department of HIV/GU Medicine, Chelsea and Westminster Hospital, London (United Kingdom); Michailidis, C. [Department of Radiology and Department of HIV/GU Medicine, Chelsea and Westminster Hospital, London (United Kingdom); Pozniak, A.L. [Department of Radiology and Department of HIV/GU Medicine, Chelsea and Westminster Hospital, London (United Kingdom); Padley, S.P.G. [Department of Radiology and Department of HIV/GU Medicine, Chelsea and Westminster Hospital, London (United Kingdom)

    2006-10-15

    Aim: To determine the radiological manifestations of IRIS (immune reconstitution inflammatory syndrome) in patients with HIV and mycobacterium tuberculosis co-infection, in the context of their demographic and clinical data. Materials and methods: The radiological imaging, demographic and clinical data of 11 patients diagnosed with IRIS associated with HIV and mycobacterial tuberculosis co-infection were studied retrospectively. Where available, follow-up imaging studies were also reviewed. Results: The most common radiological feature of IRIS was lymph node enlargement (73%), with central low attenuation centres, in keeping with necrosis, present in most of these cases (88%). Most commonly affected were intra-abdominal nodes (70%), followed by axillary (40%) and mediastinal lymph nodes (36%). Within the lung parenchyma, diffuse, bilateral pulmonary nodules were seen in 55% of cases. Unilateral small volume pleural effusions were seen in two cases with associated parenchymal changes seen in only one. Small volume ascites was seen in two cases. Thirty-six percent of cases presented with new or worsening abscesses despite treatment. In this context, image-guided radiological drainage proved a useful adjunct to the conventional medical therapy for IRIS. The most common clinical signs of IRIS included fever (64%), abdominal pain (36%) and cough (27%). Conclusion: We have described the radiological features that are characteristic in IRIS and the importance of putting these into context with the clinical and pathological findings as part of a multidisciplinary approach in making the diagnosis. The role of the radiologist is central in diagnosis, monitoring of disease progression and management of complications in patients with IRIS.

  7. Trade off between variable and fixed size normalization in orthogonal polynomials based iris recognition system.

    Science.gov (United States)

    Krishnamoorthi, R; Anna Poorani, G

    2016-01-01

    Iris normalization is an important stage in any iris biometric, as it has a propensity to trim down the consequences of iris distortion. To indemnify the variation in size of the iris owing to the action of stretching or enlarging the pupil in iris acquisition process and camera to eyeball distance, two normalization schemes has been proposed in this work. In the first method, the iris region of interest is normalized by converting the iris into the variable size rectangular model in order to avoid the under samples near the limbus border. In the second method, the iris region of interest is normalized by converting the iris region into a fixed size rectangular model in order to avoid the dimensional discrepancies between the eye images. The performance of the proposed normalization methods is evaluated with orthogonal polynomials based iris recognition in terms of FAR, FRR, GAR, CRR and EER.

  8. Representation of storms effects in IRI: NmF2, variability, TEC

    Science.gov (United States)

    Araujo-Pradere, Eduardo

    Kalman filter-based code, and the storm response is studied as a ratio to the quiet periods preceding the storms, and sorted as a function of latitude and a storm index. From the data set built, consistent features from storm to storm were found, and they were more apparent when separating the data between "driven" phase of the storm (rising integral of ap) and the "recovery" phase (declining integral of ap). The consistent features already identified could eventually become the basis for an empirical storm-time model for TEC, suitable for its inclusion in IRI.

  9. Cogeneration of Electricity and Potable Water Using The International Reactor Innovative And Secure (IRIS) Design

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, D.T.; Binder, J.L.; Kostin, V.I.; Panov, Y.K.; Polunichev, V.; Ricotti, M.E.; Conti, D.; Alonso, G.

    2004-10-06

    The worldwide demand for potable water has been steadily growing and is projected to accelerate, driven by a continued population growth and industrialization of emerging countries. This growth is reflected in a recent market survey by the World Resources Institute, which shows a doubling in the installed capacity of seawater desalination plants every ten years. The production of desalinated water is energy intensive, requiring approximately 3-6 kWh/m3 of produced desalted water. At current U.S. water use rates, a dedicated 1000 MW power plant for every one million people would be required to meet our water needs with desalted water. Nuclear energy plants are attractive for large scale desalination application. The thermal energy produced in a nuclear plant can provide both electricity and desalted water without the production of greenhouse gases. A particularly attractive option for nuclear desalination is to couple a desalination plant with an advanced, modular, passively safe reactor design. The use of small-to-medium sized nuclear power plants allows for countries with smaller electrical grid needs and infrastructure to add new electrical and water capacity in more appropriate increments and allows countries to consider siting plants at a broader number of distributed locations. To meet these needs, a modified version of the International Reactor Innovative and Secure (IRIS) nuclear power plant design has been developed for the cogeneration of electricity and desalted water. The modular, passively safe features of IRIS make it especially well adapted for this application. Furthermore, several design features of the IRIS reactor will ensure a safe and reliable source of energy and water even for countries with limited nuclear power experience and infrastructure. The IRIS-D design utilizes low-quality steam extracted from the low-pressure turbine to boil seawater in a multi-effect distillation desalination plant. The desalination plant is based on the horizontal

  10. Floppy iris syndrome with oral imipramine: A case series

    Directory of Open Access Journals (Sweden)

    Arvind Gupta

    2012-01-01

    Full Text Available Intraoperative floppy iris syndrome (IFIS has commonly been seen with long-term use of α1-adrenoceptor blocking agents. We observed IFIS in three patients during phacoemulsification due to oral imipramine therapy. The three patients took imipramine for 25 years, 10 months and 1 year, respectively. However, only the first patient was on oral therapy at the time of surgery, while the other two patients had stopped 4 months and 2 months prior to undergoing phacoemulsification. The first and third patients developed complete IFIS features, while the second had only partial IFIS characteristics. Phacoemulsification could be completed in all three patients without any complication. None of these patients had history of taking any of the α1-adrenoceptor blocking agents. This is the first anecdotal report of IFIS with the oral use of imipramine and hence further evidences are required to ascertain the association of oral imipramine therapy and IFIS. However, ophthalmologists undertaking phacoemulsification on patients on imipramine therapy should be alert for the occurrence of IFIS.

  11. The SPES3 Experimental Facility Design for the IRIS Reactor Simulation

    Directory of Open Access Journals (Sweden)

    Mario Carelli

    2009-01-01

    Full Text Available IRIS is an advanced integral pressurized water reactor, developed by an international consortium led by Westinghouse. The licensing process requires the execution of integral and separate effect tests on a properly scaled reactor simulator for reactor concept, safety system verification, and code assessment. Within the framework of an Italian R&D program on Nuclear Fission, managed by ENEA and supported by the Ministry of Economic Development, the SPES3 facility is under design and will be built and operated at SIET laboratories. SPES3 simulates the primary, secondary, and containment systems of IRIS with 1 : 100 volume scale, full elevation, and prototypical thermal-hydraulic conditions. The simulation of the facility with the RELAP5 code and the execution of the tests will provide a reliable tool for data extrapolation and safety analyses of the final IRIS design. This paper summarises the main design steps of the SPES3 integral test facility, underlying choices and phases that lead to the final design.

  12. Low-level feature extraction for edge detection using genetic programming.

    Science.gov (United States)

    Fu, Wenlong; Johnston, Mark; Zhang, Mengjie

    2014-08-01

    Edge detection is a subjective task. Traditionally, a moving window approach is used, but the window size in edge detection is a tradeoff between localization accuracy and noise rejection. An automatic technique for searching a discriminated pixel's neighbors to construct new edge detectors is appealing to satisfy different tasks. In this paper, we propose a genetic programming (GP) system to automatically search pixels (a discriminated pixel and its neighbors) to construct new low-level subjective edge detectors for detecting edges in natural images, and analyze the pixels selected by the GP edge detectors. Automatically searching pixels avoids the problem of blurring edges from a large window and noise influence from a small window. Linear and second-order filters are constructed from the pixels with high occurrences in these GP edge detectors. The experiment results show that the proposed GP system has good performance. A comparison between the filters with the pixels selected by GP and all pixels in a fixed window indicates that the set of pixels selected by GP is compact but sufficiently rich to construct good edge detectors.

  13. A review of the safety features of 6M packagings for DOE programs

    Energy Technology Data Exchange (ETDEWEB)

    1988-12-01

    This report, prepared by a US Department of Energy (DOE) Task Force and organized for clarity into two-page modules, argues that the US Department of Transportation (DOT) Specification-6M packagings (hereafter referred to as 6M packaging, or simply 6M) merit continued DOE use and, if necessary, DOE certification. This report is designed to address the specific requirements of a Safety Analysis Report for Packaging (SARP). While not a SARP, this report constitutes a compilation of all available documentation on 6M packagings. The authors individually, and the Task Force collectively, believe their investigation provides justification for the continued use of 6M packagings because they meet criteria for quality assurance and for safety under normal and accident conditions as defined by the US Nuclear Regulatory Commission (NRC) regulations. This report may be used by DOE managers to assist in deliberations on future requirements for 6M packagings as they are required to support DOE programs. For the purpose of ready evaluation, this report includes categorical topics found in Nuclear Regulatory Guide 7.9, the topical guideline for SARPs. The format, however, will (it is hoped) pleasantly surprise customary reader expectations. For, while maintaining categorical headings and subheadings found in SARPs as a skeleton, the Task Force chose to adopt the document design principles developed by Hughes Aircraft in the 1960s, ''Sequential Thematic Organization of Publications'' (STOP). 37 figs.

  14. Quantitative analysis of iris changes following mydriasis in subjects with different mechanisms of angle closure.

    Science.gov (United States)

    Zhang, Ye; Li, Si Zhen; Li, Lei; He, Ming Guang; Thomas, Ravi; Wang, Ning Li

    2015-01-08

    We estimate and compare change in iris cross-sectional area (IA) after physiologic and pharmacologic mydriasis in subjects with different dominant mechanisms for primary angle closure. Anterior segment optical coherence tomography (AS-OCT) measurements in light, dark, and following pharmacologic dilation were obtained on primary angle closure suspects (PACS), primary angle closure (PAC), and primary angle closure glaucoma (PACG) examined during the 5-year follow-up of the Handan Eye Study. Subjects were categorized into three subgroups according to their dominant angle closure (AC) mechanisms as determined by AS-OCT: pupillary block (PB), plateau iris configuration (PIC), and thick peripheral iris roll (TPIR). The IA and other biometric parameters measured using the Zhongshan Angle Assessment Program in the right eyes of all subjects were analyzed. A total of 364 right eyes of subjects with PACS (333), and PAC/PACG (31) was included in the analysis. Significant differences in the change of IAs (P = 0.030), IA loss per mm pupil diameter (PD) increase (P = 0.001) in light versus pharmacologic dilation, and IA loss per mm PD increase (P = 0.011) from dark versus pharmacologic dilation were observed among the three groups. The smallest decrease occurred in the PB group. There are significant differences in IA and IA loss per mm of pupil change following physiologic or pharmacologic mydriasis in Chinese subjects with dissimilar dominant mechanisms for AC. Dynamic iris change may have a more important role in angle closure where PB is the dominant mechanism. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  15. Dynamic Iris Changes as a Risk Factor in Primary Angle Closure Disease.

    Science.gov (United States)

    Zhang, Ye; Li, Si Zhen; Li, Lei; He, Ming Guang; Thomas, Ravi; Wang, Ning Li

    2016-01-01

    We studied the association between dynamic iris changes and the spectrum of primary angle closure disease (PACD), using the anterior segment optical coherence tomography (ASOCT). Eligible primary angle closure (PAC), primary angle closure glaucoma (PACG), age, and sex comparable primary angle closure suspects (PACS) and normal subjects from the 5-year follow-up of the Handan Eye Study underwent ASOCT testing in dark and light conditions. The right eye of each subject was analyzed and biometric parameters including iris cross-sectional area (IA), lens vault (LV), pupil diameter (PD), and centroid-to-centroid distance (CCD) were calculated using the Zhongshan Angle Assessment Program. Totals of 31 PACS, 31 PAC/PACG, and 31 normal eyes were eligible for analysis. Loss of IA per mm PD increase in the dark compared to light was 0.18 mm in PACS, 0.13 mm in PAC/PACG, and 0.24 mm in normal (P = 0.015 between groups) groups. Diagnoses of normal (P = 0.001) and a smaller PD in light (P = 0.003) were statistically significant determinants of a larger IA loss per mm PD increase in the dark compared to light. Logistic regression analysis showed that LV (P = 0.002) and IA loss per mm PD increase (P = 0.017) were risk factors for an occludable angle. Significant differences in iris behavior in the dark compared to light in PACS, PACD, and normal eyes add to the evidence that dynamic iris change has a role in the pathogenesis of PAC in a rural Chinese population.

  16. Peer Review Comments on the IRIS Assessment of Benzene

    Science.gov (United States)

    Attachment to IRIS file for benzene, January 19, 2000, RESPONSE TO THE PEER REVIEW COMMENTS, II. Extrapolation of the Benzene Inhalation Unit Risk Estimate to the Oral Route of Exposure (EPA/NCEA-W-0517, July 1999)

  17. Mid-Columbia - Eradication of Yellow-flag Iris 2013

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The project as described was to attempt to eradicate yellow-flag iris from Toppenish, McNary and Columbia National Wildlife Refuges using chemical and, where...

  18. IRIS Toxicological Review of Trichloroacetic Acid (TCA) (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  19. IRIS Toxicological Review of Formaldehyde (Inhalation) (External Review Draft 2010)

    Science.gov (United States)

    UPDATE EPA is currently revising its Integrated Risk Information System (IRIS) assessment of formaldehyde to address the 2011 NAS peer review recommendations. This assessment addresses both noncancer and cancer human health effects that are relevant to assessing ...

  20. The Education of Iris Macfarlane, 1922-1939

    OpenAIRE

    Macfarlane, Alan

    2015-01-01

    An account of an English girl's education. Born in India in 1922, Iris Macfarlane's diaries, letters and school reports provide a picture of being sent home to England and being educated in a series of schools.

  1. Embedded Design Research of Iris Information Acquisition System

    Directory of Open Access Journals (Sweden)

    Huiyan Xu

    2014-09-01

    Full Text Available In view of the limitation of traditional identification, it is easy to lose and copy keys, cards or ID cards, and it is easy to forget the password, so we designed an embedded application system based on the iris identification technology, which can realize the functions of gathering, inputting, and registering the iris information and identification. The hardware circuit was designed by using advanced RISC machines (ARM embedded microprocessor as the core. The iris sensor was used to gather the iris information, and the development of software was accomplished with the embedded OS Windows CE. The system can be used on the company entrance guard system, customs security of airport and criminal identification.

  2. Hinode SOT Images Coaligned with IRIS Level 2 Data Products

    Science.gov (United States)

    Tarbell, Theodore D.

    2016-05-01

    We have produced new data products consisting of HInode SOT images coaligned with simultaneous observations by IRIS. Cross-correlation between SOT Filtergraph images and similar SDO wavelength bands provides accurate pointing coordinates for nearly all SOT images, correcting for the solar flows followed by the SOT correlation tracker. Data from all of 2014 and 2015 and part of 2013 have been processed by now and verification of the data products is ongoing. The cubes of SOT images are created in IRIS level 2 data format and can be read using IRIS software tools. In addition, the SOT cubes can be studied using CRISPEX along with the corresponding IRIS Level 3 data. Work has begun to process time series of SOT Spectro-Polarimeter data into cubes of images that can be studied the same way. Examples of some datasets from IHOPs, both FG and SP, will be shown and instructions given for accessing and viewing the available datasets.

  3. Mid-Columbia - Yellow-flag Iris Control

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Yellow-flag iris is an escaped ornamental rhizomatous perennial herb that forms dense vegetative mats in riparian and wetland areas. These mats can displace most...

  4. IRIS Toxicological Review for Acrylamide (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review for Acrylamide, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process<...

  5. IRIS Toxicological Review of Hexavalent Chromium (Peer Review Plan)

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hexavalent chromium that will appear on the Integrated Risk Information System (IRIS) database.

  6. IRIS Toxicological Review of Hydrogen Cyanide (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hydrogen cyanide and cyanide salts that will appear on the Integrated Risk Information System (IRIS) database.

  7. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Dichloromethane that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  8. IRIS Toxicological Review of Methanol (Noncancer) (Final Report)

    Science.gov (United States)

    EPA conducted a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Methanol (noncancer) , this is finalized and posted on the IRIS Web site.

  9. Iterative Directional Ray Based Iris Segmentation for Challenging Periocular Images

    Science.gov (United States)

    2011-12-03

    following pre-processing scheme was used: (i) illumination normalization, (ii) eye center detection, and (iii) inpainting . 1 See http://www.nist.gov/itl/iad...center detection for sample FOCS imagery (marked by white dots) 3.3 Inpainting Specular reflections located within the iris region are additional...factors affecting the success of iris segmentation. We use inpainting for alleviating this effect. In particular, an inpainting method [10] is applied to

  10. SINGLE FRAME SUPER RESOLUTION OF NONCOOPERATIVE IRIS IMAGES

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-11-01

    Full Text Available Image super-resolution, a process to enhance image resolution, has important applications in biometrics, satellite imaging, high definition television, medical imaging, etc. The long range captured iris identification systems often suffer from low resolution and meager focus of the captured iris images. These degrade the iris recognition performance. This paper proposes enhanced iterated back projection (EIBP method to super resolute the long range captured iris polar images. The performance of proposed method is tested and analyzed on CASIA long range iris database by comparing peak signal to noise ratio (PSNR and structural similarity index (SSIM with state-of-the-art super resolution (SR algorithms. It is further analyzed by increasing the up-sampling factor. Performance analysis shows that the proposed method is superior to state-of-the-art algorithms, the peak signal-to-noise ratio improved about 0.1-1.5 dB. The results demonstrate that the proposed method is well suited to super resolve the iris polar images captured at a long distance

  11. Association between U.S. state AIDS Drug Assistance Program (ADAP features and HIV antiretroviral therapy initiation, 2001-2009.

    Directory of Open Access Journals (Sweden)

    David B Hanna

    Full Text Available U.S. state AIDS Drug Assistance Programs (ADAPs are federally funded to provide antiretroviral therapy (ART as the payer of last resort to eligible persons with HIV infection. States differ regarding their financial contributions to and ways of implementing these programs, and it remains unclear how this interstate variability affects HIV treatment outcomes.We analyzed data from HIV-infected individuals who were clinically-eligible for ART between 2001 and 2009 (i.e., a first reported CD4+ <350 cells/uL or AIDS-defining illness from 14 U.S. cohorts of the North American AIDS Cohort Collaboration on Research and Design (NA-ACCORD. Using propensity score matching and Cox regression, we assessed ART initiation (within 6 months following eligibility and virologic suppression (within 1 year based on differences in two state ADAP features: the amount of state funding in annual ADAP budgets and the implementation of waiting lists. We performed an a priori subgroup analysis in persons with a history of injection drug use (IDU.Among 8,874 persons, 56% initiated ART within six months following eligibility. Persons living in states with no additional state contribution to the ADAP budget initiated ART on a less timely basis (hazard ratio [HR] 0.73, 95% CI 0.60-0.88. Living in a state with an ADAP waiting list was not associated with less timely initiation (HR 1.12, 95% CI 0.87-1.45. Neither additional state contributions nor waiting lists were significantly associated with virologic suppression. Persons with an IDU history initiated ART on a less timely basis (HR 0.67, 95% CI 0.47-0.95.We found that living in states that did not contribute additionally to the ADAP budget was associated with delayed ART initiation when treatment was clinically indicated. Given the changing healthcare environment, continued assessment of the role of ADAPs and their features that facilitate prompt treatment is needed.

  12. Aqueous humor tyrosinase activity is indicative of iris melanocyte toxicity.

    Science.gov (United States)

    Mahanty, Sarmistha; Kawali, Ankush A; Dakappa, Shruthi Shirur; Mahendradas, Padmamalini; Kurian, Mathew; Kharbanda, Varun; Shetty, Rohit; Setty, Subba Rao Gangi

    2017-09-01

    Antibiotics such as fluoroquinolones (FQLs) are commonly used to treat ocular infections but are also known to cause dermal melanocyte toxicity. The release of dispersed pigments from the iris into the aqueous humor has been considered a possible ocular side effect of the systemic administration of FQLs such as Moxifloxacin, and this condition is known as bilateral acute iris transillumination (BAIT). Bilateral acute depigmentation of iris (BADI) is a similar condition, with iris pigment released into the aqueous, but it has not been reported as a side effect of FQL. Iris pigments are synthesized by the melanogenic enzyme tyrosinase (TYR) and can be detected but not quantified by using slit-lamp biomicroscopy. The correlation between dispersed pigments in the aqueous and the extent of melanocyte toxicity due to topical antibiotics in vivo is not well studied. Here, we aimed to study the effect of topical FQLs on iris tissue, the pigment release in the aqueous humor and the development of clinically evident iris atrophic changes. We evaluated this process by measuring the activity of TYR in the aqueous humor of 82 healthy eyes undergoing cataract surgery following topical application of FQLs such as Moxifloxacin (27 eyes, preservative-free) or Ciprofloxacin (29 eyes, with preservative) or the application of non-FQL Tobramycin (26 eyes, with preservative) as a control. In addition, the patients were questioned and examined for ocular side effects in pre- and post-operative periods. Our data showed a significantly higher mean TYR activity in the aqueous humor of Ciprofloxacin-treated eyes compared to Moxifloxacin- (preservative free, p humor from both Ciprofloxacin- and Moxifloxacin-treated eyes showed the presence of soluble TYR enzyme, thus reflecting its toxicity to iris melanocytes and corresponding to its activity in the aqueous humor. Intriguingly, none of these patients developed any clinically appreciable ocular side effects characteristic of BAIT or BADI

  13. The iris family (Iridaceae in the flora of eastern Indochina

    Directory of Open Access Journals (Sweden)

    L. V. Averyanov

    2016-03-01

    Full Text Available Iris family in the countries of eastern part of Indochina Peninsula, such as Cambodia, Laos and Viet­nam includes lone native genus – Iris L. with two aboriginal species – I. japonica Thunb. and I. tectorum Maxim. Iris japonica is often cultivated as an outdoor ornamental plant in mountainous regions in the northern Vietnam, where it occasionally naturalizes. Herbarium specimens of I. japonica, collected in central Laos near Nape town, probably represent southernmost locality of the Iris genus in Eurasia. Iris tectorum was discovered in native, primary plant communities of karstic highly eroded limestone in Cao Bang province (Bao Lac district of the northern Vietnam. This species is recorded as new for the flora of the Indochina Peninsula. The report of I. collettii Hook. f. on the territory of peninsular flora does not yet confirmed by herbaria and remains doubtful. Data on taxonomy, authentic specimens, distribution, habitats, phenology, conservation status and biology are provided for all Iris species. The identification key for Iris species is compiled, as well as dotted distribution maps on the territory of countries of eastern Indochina. Other representatives of the family from such genera as Belamcanda Adans. (B. chinensis (L. Redouté, Crocosmia Planch. (C. × crocosmiiflora (G. Nicholson N. E. Br., Eleutherine Herb. (E. bulbosa (Mill. Urb., Freesia Klatt (F. refracta (Jacq. Klatt., Gladiolus L. (numerous horticultural forms и Trimezia Salisb. ex Herb. (T. martinicensis (Jacq. Herb. reported from Indochina are introduced cultivated ornamental plants capable to occasional naturaliza­tion as an adventive element of the Indochinese flora.

  14. IRI Task Force Activity at ICTP: Proposed improvements for the IRI region below the F peak

    Science.gov (United States)

    Radicella, S. M.; Bilitza, D.; Reinisch, B. W.; Adeniyi, J. O.; Gonzalez, M. E. Mosert; Zolesi, B.; Zhang, M. L.; Zhang, S. R.

    The Aeronomy and Radiopropagation Laboratory of the International Center for Theoretical Physics (ICTP) in Trieste, Italy has hosted special IRI Task Force Activities (TFAs) annually since 1994. This article reviews the format and results of the 1994, 1995, and 1996 TFAs. The prime focus of these TFAs has been the F1 region and the bottomside F2 region. Each meeting has tackled a specific subset of modeling problems using morning round-table discussions and afternoon computer sessions to solve the `problem of the day'. Data, models and related software were provided by the participants on electronic media or were retrieved over the internet. As a result of this effort several improvements have been proposed for the IRI description of the region below the F2 peak: (1) A more accurate description of the probability of the existence of the F1 layer, (2) A more realistic description of the bottomside thickness parameters, (3) A set of new anchor points to define the intermediate region between the E valley top and the bottomside F2 region.

  15. Fine structural evaluation of the iris after unilateral treatment with latanoprost in patients undergoing bilateral trabeculectomy (the Mainz II study).

    Science.gov (United States)

    Pfeiffer, Norbert; Grierson, Ian; Goldsmith, Helen; Appleton, Paul; Hochgesand, Dirk; Winkgen, Andrea

    2003-01-01

    To investigate by masked electron microscopy whether 6 months of topical latanoprost caused pathological changes in the peripheral iris of patients with glaucoma. Seventeen patients with bilateral primary open-angle glaucoma requiring trabeculectomy were recruited for this study. The iridectomy taken during surgery on the first eye served as a control. The second test eye was treated topically with latanoprost for 6 months before its trabeculectomy. Fourteen patients completed the treatment arm of the study, and 1 of these underwent marked color change. As a result, 31 iridectomy specimens were fixed, coded, and evaluated. The specimens were evaluated for evidence of stromal inflammation, vascular alterations, and stromal and posterior epithelial degeneration. None of these features was evident in any of the 31 iridectomy specimens. There was evidence of the incidence of free melanin granules in the stroma, melanin turnover, abundance of stromal clump cells, atypical cellular features in melanocytes, and prominence of the anterior border. After code breaking, it was evident that none of these features distinguished the test from the fellow irises in our group. The patient with color change in the test iris did not stand out from the others in this analysis. Qualitative reexamination of further sections after unmasking gave the impression of increased melanin granule numbers in the melanocytes of the anterior border region. The ultrastructure of the iridectomies from the latanoprost-treated eyes and the fellow eyes conformed to published standards for normal iris. There was no evidence of early ultrastructural changes, which might have been the harbingers of latanoprost-induced iris abnormality.

  16. Comparison of the observed topside ionospheric and plasmaspheric electron content derived from the COSMIC podTEC measurements with the IRI_Plas model results

    Science.gov (United States)

    Zhang, Man-Lian; Liu, Libo; Wan, Weixing; Ning, Baiqi

    2017-07-01

    In this paper, variations of the topside ionospheric and plasmaspheric electron contents (TPEC) in the altitude range of ∼800 to 20,200 km are compared with the IRI_Plas model results for the low (2008) and high (2012) solar activity years using TEC data (podTEC) derived from the upward-looking precise orbit determination antenna on board COSMIC low Earth orbit (LEO) satellites tracking the GPS signals. For each year, the dataset were divided into groups according to four seasons: M-Equinox (March, April), J-Solstice (May June, July and August), S-Equinox (September, October) and D-Solstice (January, February, November, and December). Our study showed that the IRI_Plas model is able to reproduce reasonably well the main features of the observational TPEC's latitudinal, diurnal as well as seasonal variation tendency when no longitudinal difference is taken into account. However, there exist discrepancies between the observational TPEC and the model results. Except for the daytime hours in the Equinoctial seasons of the high solar activity year 2012 when the IRI_Plas model results showed an overestimation, in general, the IRI_Plas model results underestimate the observational ones, in particular at nighttime hours in the low-latitude region. When the longitudinal difference is taken into account, the comparison study showed that the longitudinal dependence effect shown in the observational TPEC's seasonal variations was not captured by the IRI_Plas model result. Moreover, the IRI_Plas model results tend to show a double-peak structure in the low-latitude region, a feature not appearing in the observational results.

  17. Dynamic analysis of iris configuration with anterior segment optical coherence tomography.

    Science.gov (United States)

    Cheung, Carol Yim-lui; Liu, Shu; Weinreb, Robert N; Liu, Jing; Li, Haitao; Leung, Dexter Yu-lung; Dorairaj, Syril; Liebmann, Jeffrey; Ritch, Robert; Lam, Dennis Shun Chiu; Leung, Christopher Kai-shun

    2010-08-01

    To evaluate dynamic changes in iris configuration and their association with anterior chamber angle width by using anterior segment optical coherence tomography (ASOCT). Forty-six normal subjects with open angles and 40 with narrow angles (Shaffer grade iris bowing were captured with real-time video recording and nasal iris bowing, nasal anterior chamber angle, and pupil diameter were measured in serial image frames selected from the video capture. The associations between iris bowing, iris thickness, anterior chamber depth (ACD), age, anterior chamber angle, and pupillary diameter measurements were evaluated with univariate and multivariate regression analyses. The relationship between iris bowing and pupil diameter was largely linear, with three dynamic patterns observed: (1) convex-to-convex (iris remains convex in dark and light); (2) concave-to-convex (iris changes from concave to convex from light to dark); and (3) concave-to-concave (iris remains concave in dark and light). All the subjects with narrow angles had convex-to-convex anatomy, although 43% of the subjects with open angles also demonstrated this pattern. These individuals were older and had shorter axial length (both with P iris bowing in the light and dark. ACD and iris bowing were independently associated with anterior chamber angle width. Independent of ACD, iris bowing is an important biometric parameter that determines angle width. Investigation of iris dynamics may offer a new perspective in understanding the risk and mechanism of primary angle closure.

  18. Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

    Directory of Open Access Journals (Sweden)

    Alexander K. Schuster

    2017-01-01

    Full Text Available Purpose. To report the distribution of iris conicity (steepness of the iris cone, investigate associated factors, and test whether pseudophakia allows the iris to sink back. Methods. A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus was performed including automated measurement of iris conicity. 3708 phakic subjects, 144 subjects with bilateral and 39 subjects with unilateral pseudophakia were included. Multivariable analyses were carried out to determine independently associated systemic and ocular factors for iris conicity in phakic eyes. Results. Mean iris conicity was 8.28° ± 3.29° (right eyes. Statistical analysis revealed associations between steeper iris conicity and shallower anterior chamber depth, thicker human lens and higher corneal power in multivariable analysis, while older age was related to a flatter iris conicity. Refraction, axial length, central corneal thickness, pupil diameter, and intraocular pressure were not associated with iris conicity. Pseudophakia resulted in a 5.82° flatter iris conicity than in the fellow phakic eyes. Conclusions. Associations indicate a correlation between iris conicity with risk factors for angle-closure, namely, shallower anterior chamber depth and thicker human lens. In pseudophakic eyes, iris conicity is significantly lower, indicating that cataract surgery flattens the iris.

  19. Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

    Science.gov (United States)

    Pfeiffer, Norbert; Nickels, Stefan; Schulz, Andreas; Wild, Philipp S.; Blettner, Maria; Lackner, Karl; Beutel, Manfred E.; Münzel, Thomas; Vossmerbaeumer, Urs

    2017-01-01

    Purpose To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. Methods A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed including automated measurement of iris conicity. 3708 phakic subjects, 144 subjects with bilateral and 39 subjects with unilateral pseudophakia were included. Multivariable analyses were carried out to determine independently associated systemic and ocular factors for iris conicity in phakic eyes. Results Mean iris conicity was 8.28° ± 3.29° (right eyes). Statistical analysis revealed associations between steeper iris conicity and shallower anterior chamber depth, thicker human lens and higher corneal power in multivariable analysis, while older age was related to a flatter iris conicity. Refraction, axial length, central corneal thickness, pupil diameter, and intraocular pressure were not associated with iris conicity. Pseudophakia resulted in a 5.82° flatter iris conicity than in the fellow phakic eyes. Conclusions Associations indicate a correlation between iris conicity with risk factors for angle-closure, namely, shallower anterior chamber depth and thicker human lens. In pseudophakic eyes, iris conicity is significantly lower, indicating that cataract surgery flattens the iris. PMID:29085672

  20. Iris-fixated posterior chamber intraocular lenses in children.

    Science.gov (United States)

    Yen, Kimberly G; Reddy, Ashvini K; Weikert, Mitchell P; Song, Yeon; Hamill, Marshall B

    2009-01-01

    To report the short-term outcomes and complications of iris-fixated posterior chamber intraocular lenses (PCIOL) in the pediatric population. Retrospective, observational case study. Twelve consecutive pediatric patients (17 eyes) underwent placement of foldable iris-sutured PCIOLs between September 1, 2004 and September 30, 2007 by two anterior segment surgeons at a single academic center. Outcome measures included change in visual acuity (VA) and complications. In our series, there was a higher rate of dislocation of iris-sutured IOLs in patients with a history of ectopia lentis resulting from Marfan syndrome or hereditary or idiopathic causes than in patients being treated for aphakia resulting from other causes (45% vs 0%). Mean final VA improved by 0.23 logarithm of the minimum angle of resolution units from preoperative baseline. One eye of a Marfan patient sustained a retinal detachment eight months after dislocation of the PCIOL, and one patient experienced iris capture of the IOL after surgery. Iris-fixated IOLs are reasonable alternative to transsclerally sutured IOLs to correct aphakia in pediatric patient. Dislocation of the IOLs can occur, however, and there is concern for suture degradation over time. The procedure should be considered with caution in pediatric patients.

  1. On a methodology for robust segmentation of nonideal iris images.

    Science.gov (United States)

    Schmid, Natalia A; Zuo, Jinyu

    2010-06-01

    Iris biometric is one of the most reliable biometrics with respect to performance. However, this reliability is a function of the ideality of the data. One of the most important steps in processing nonideal data is reliable and precise segmentation of the iris pattern from remaining background. In this paper, a segmentation methodology that aims at compensating various nonidealities contained in iris images during segmentation is proposed. The virtue of this methodology lies in its capability to reliably segment nonideal imagery that is simultaneously affected with such factors as specular reflection, blur, lighting variation, occlusion, and off-angle images. We demonstrate the robustness of our segmentation methodology by evaluating ideal and nonideal data sets, namely, the Chinese Academy of Sciences iris data version 3 interval subdirectory, the iris challenge evaluation data, the West Virginia University (WVU) data, and the WVU off-angle data. Furthermore, we compare our performance to that of our implementation of Camus and Wildes's algorithm and Masek's algorithm. We demonstrate considerable improvement in segmentation performance over the formerly mentioned algorithms.

  2. A Study on Iris Localization and Recognition on Mobile Phones

    Directory of Open Access Journals (Sweden)

    Dae Sik Jeong

    2007-11-01

    Full Text Available A new iris recognition method for mobile phones based on corneal specular reflections (SRs is discussed. We present the following three novelties over previous research. First, in case of user with glasses, many noncorneal SRs may happen on the surface of glasses and it is very difficult to detect genuine SR on the cornea. To overcome such problems, we propose a successive on/off dual illuminator scheme to detect genuine SRs on the corneas of users with glasses. Second, to detect SRs robustly, we estimated the size, shape, and brightness of the SRs based on eye, camera, and illuminator models. Third, the detected eye (iris region was verified again using the AdaBoost eye detector. Experimental results with 400 face images captured from 100 persons with a mobile phone camera showed that the rate of correct iris detection was 99.5% (for images without glasses and 98.9% (for images with glasses or contact lenses. The consequent accuracy of iris authentication was 0.05% of the EER (equal error rate based on detected iris images.

  3. Epigenetic randomness, complexity and singularity of human iris patterns.

    Science.gov (United States)

    Daugman, J; Downing, C

    2001-08-22

    We investigated the randomness and uniqueness of human iris patterns by mathematically comparing 2.3 million different pairs of eye images. The phase structure of each iris pattern was extracted by demodulation with quadrature wavelets spanning several scales of analysis. The resulting distribution of phase sequence variation among different eyes was precisely binomial, revealing 244 independent degrees of freedom. This amount of statistical variability corresponds to an entropy (information density) of about 3.2 bits mm(-2) over the iris. It implies that the probability of two different irides agreeing by chance in more than 70% of their phase sequence is about one in 7 billion. We also compared images of genetically identical irides, from the left and right eyes of 324 persons, and from monozygotic twins. Their relative phase sequence variation generated the same statistical distribution as did unrelated eyes. This indicates that apart from overall form and colour, iris patterns are determined epigenetically by random events in the morphogenesis of this tissue. The resulting diversity, and the combinatorial complexity created by so many dimensions of random variation, mean that the failure of a simple test of statistical independence performed on iris patterns can serve as a reliable rapid basis for automatic personal identification.

  4. Association between U.S. State AIDS Drug Assistance Program (ADAP) Features and HIV Antiretroviral Therapy Initiation, 2001–2009

    Science.gov (United States)

    Hanna, David B.; Buchacz, Kate; Gebo, Kelly A.; Hessol, Nancy A.; Horberg, Michael A.; Jacobson, Lisa P.; Kirk, Gregory D.; Kitahata, Mari M.; Korthuis, P. Todd; Moore, Richard D.; Napravnik, Sonia; Patel, Pragna; Silverberg, Michael J.; Sterling, Timothy R.; Willig, James H.; Collier, Ann; Samji, Hasina; Thorne, Jennifer E.; Althoff, Keri N.; Martin, Jeffrey N.; Rodriguez, Benigno; Stuart, Elizabeth A.; Gange, Stephen J.

    2013-01-01

    Background U.S. state AIDS Drug Assistance Programs (ADAPs) are federally funded to provide antiretroviral therapy (ART) as the payer of last resort to eligible persons with HIV infection. States differ regarding their financial contributions to and ways of implementing these programs, and it remains unclear how this interstate variability affects HIV treatment outcomes. Methods We analyzed data from HIV-infected individuals who were clinically-eligible for ART between 2001 and 2009 (i.e., a first reported CD4+ <350 cells/uL or AIDS-defining illness) from 14 U.S. cohorts of the North American AIDS Cohort Collaboration on Research and Design (NA-ACCORD). Using propensity score matching and Cox regression, we assessed ART initiation (within 6 months following eligibility) and virologic suppression (within 1 year) based on differences in two state ADAP features: the amount of state funding in annual ADAP budgets and the implementation of waiting lists. We performed an a priori subgroup analysis in persons with a history of injection drug use (IDU). Results Among 8,874 persons, 56% initiated ART within six months following eligibility. Persons living in states with no additional state contribution to the ADAP budget initiated ART on a less timely basis (hazard ratio [HR] 0.73, 95% CI 0.60–0.88). Living in a state with an ADAP waiting list was not associated with less timely initiation (HR 1.12, 95% CI 0.87–1.45). Neither additional state contributions nor waiting lists were significantly associated with virologic suppression. Persons with an IDU history initiated ART on a less timely basis (HR 0.67, 95% CI 0.47–0.95). Conclusions We found that living in states that did not contribute additionally to the ADAP budget was associated with delayed ART initiation when treatment was clinically indicated. Given the changing healthcare environment, continued assessment of the role of ADAPs and their features that facilitate prompt treatment is needed. PMID:24260137

  5. A Robust Iris Identification System Based on Wavelet Packet Decomposition and Local Comparisons of the Extracted Signatures

    National Research Council Canada - National Science Library

    Rossant, Florence; Mikovicova, Beata; Adam, Mathieu; Trocan, Maria

    2010-01-01

    ...: iris segmentation, signature extraction, and signature comparison. An accurate and robust pupil and iris segmentation process, taking into account eyelid occlusions, is first detailed and evaluated...

  6. Template characterization and correlation algorithm created from segmentation for the iris biometric authentication based on analysis of textures implemented on a FPGA

    Science.gov (United States)

    Giacometto, F. J.; Vilardy, J. M.; Torres, C. O.; Mattos, L.

    2011-01-01

    Among the most used biometric signals to set personal security permissions, taker increasingly importance biometric iris recognition based on their textures and images of blood vessels due to the rich in these two unique characteristics that are unique to each individual. This paper presents an implementation of an algorithm characterization and correlation of templates created for biometric authentication based on iris texture analysis programmed on a FPGA (Field Programmable Gate Array), authentication is based on processes like characterization methods based on frequency analysis of the sample, and frequency correlation to obtain the expected results of authentication.

  7. Ethnicity prediction and classification from iris texture patterns: A survey on recent advances

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu

    2017-03-01

    Full Text Available The prediction and classification of ethnicity based on iris texture patterns using image processing, artificial intelligence and computer vision techniques is still a recent topic in iris biometrics. While the large body of knowledge and research...

  8. Core physics analysis of 100% MOX Core in IRIS

    Energy Technology Data Exchange (ETDEWEB)

    Franceschini, F.; Petrovic, B. [Westinghouse Electric Company LLC, Science and Technology Dept., 1344 Beulah Road, Pittsburgh, PA 15235 (United States)

    2006-07-01

    International Reactor Innovative and Secure (IRIS) is an advanced small-to-medium-size (1000 MWt) Pressurized Water Reactor (PWR), targeting deployment around 2015. Its reference core design is based on the current Westinghouse UO{sub 2} fuel with less than 5% {sup 235}U, and the analysis has been previously completed confirming good performance. The full MOX fuel core is currently under evaluation as one of the alternatives for the second wave of IRIS reactors. A full 3-D neutronic analysis has been performed to examine main core performance parameters, such as critical boron concentration, peaking factors, discharge burnup, etc. The enhanced moderation of the IRIS fuel lattice facilitates MOX core design, and all the obtained results are within the requirements, confirming viability of this option from the reactor physics standpoint. (authors)

  9. Stacking a million seismograms and other data products at the IRIS DMC

    Science.gov (United States)

    Hutko, A. R.; Bahavar, M.; Trabant, C.; Karstens, R.

    2012-12-01

    The IRIS DMC is in its third year of developing data products. Here, we highlight a new product based on stacking roughly one million seismograms to generate composite record sections that illuminate the global telseseismic wavefield. These are made using all available broadband data at the DMC for all shallow M5.7+ earthquakes from 1990-present. Within multiple narrow frequency bands ranging from 0.01 to 4.0 Hz, traces are culled based on multiple quality control metrics in order to maximize the number of clean traces and then stacked within narrow distance bins. We show record sections of nonlinearly stacked short-term/long-term average ratios (STA/LTA) in order to highlight detections of weak phases (e.g. PKPPKPPKP), as well as linear stacks of envelope functions in order to highlight coda decay rates at different frequencies. Stacks are generated for vertical, radial and tangential component data. Comparison with equivalent stacks using axi-symmetric 2D spectral-element method (SEM) synthetic seismograms will also be shown. Another new data product that will be featured is short arc Rayleigh wave source-time functions for M7+ events. We will also describe other new data products developed by external groups and recently made available from the DMC including a) a western ambient noise US cross-correlation database and b) SeisSound, an audio/video seismic waveform visualization. Finally we will report the status of data products currently in development such as animations of aftershock sequences for large earthquakes. These data products are all part of a growing collection of products produced and managed at the IRIS DMC, for the complete list please visit http://www.iris.edu/dms/products.

  10. Thirty Years of Innovation in Seismology with the IRIS Consortium

    Science.gov (United States)

    Sumy, D. F.; Woodward, R.; Aderhold, K.; Ahern, T. K.; Anderson, K. R.; Busby, R.; Detrick, R. S.; Evers, B.; Frassetto, A.; Hafner, K.; Simpson, D. W.; Sweet, J. R.; Taber, J.

    2015-12-01

    The United States academic seismology community, through the National Science Foundation (NSF)-funded Incorporated Research Institutions for Seismology (IRIS) Consortium, has promoted and encouraged a rich environment of innovation and experimentation in areas such as seismic instrumentation, data processing and analysis, teaching and curriculum development, and academic science. As the science continually evolves, IRIS helps drive the market for new research tools that enable science by establishing a variety of standards and goals. This has often involved working directly with manufacturers to better define the technology required, co-funding key development work or early production prototypes, and purchasing initial production runs. IRIS activities have helped establish de-facto international standards and impacted the commercial sector in areas such as seismic instrumentation, open-access data management, and professional development. Key institutional practices, conducted and refined over IRIS' thirty-year history of operations, have focused on open-access data availability, full retention of maximum-bandwidth, continuous data, and direct community access to state-of-the-art seismological instrumentation and software. These practices have helped to cultivate and support a thriving commercial ecosystem, and have been a key element in the professional development of multiple generations of seismologists who now work in both industry and academia. Looking toward the future, IRIS is increasing its engagement with industry to better enable bi-directional exchange of techniques and technology, and enhancing the development of tomorrow's workforce. In this presentation, we will illustrate how IRIS has promoted innovations grown out of the academic community and spurred technological advances in both academia and industry.

  11. An Analysis on Better Testing than Training Performances on the Iris Dataset

    NARCIS (Netherlands)

    Schutten, Marten; Wiering, Marco

    2016-01-01

    The Iris dataset is a well known dataset containing information on three different types of Iris flowers. A typical and popular method for solving classification problems on datasets such as the Iris set is the support vector machine (SVM). In order to do so the dataset is separated in a set used

  12. 75 FR 76982 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-12-10

    ... AGENCY Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches for... literature searches for IRIS assessments; request for information. SUMMARY: The U.S. Environmental Protection Agency (EPA) is announcing the availability of literature searches for four IRIS assessments...

  13. 75 FR 25239 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-05-07

    ... AGENCY Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches for... of literature searches for IRIS assessments; request for information. SUMMARY: The U.S. Environmental Protection Agency (EPA) is announcing the availability of literature searches for four IRIS assessments and...

  14. TREATMENT WITH THIDIAZURON IMPROVES OPENING AND VASE LIFE OF IRIS FLOWERS

    Science.gov (United States)

    The marketability of Dutch iris (Iris × hollandica) cut flowers is limited by their short display life and frequent failure to open fully. We tested the ability of thidiazuron (TDZ), a phenyl urea compound with cytokinin-like activity, to improve iris flower opening and longevity. A postharvest pu...

  15. IRIS Observations of Spicules and Structures Near the Solar Limb

    Science.gov (United States)

    Alissandrakis, C. E.; Vial, J.-C.; Koukras, A.; Buchlin, E.; Chane-Yook, M.

    2018-02-01

    We have analyzed Interface Region Imaging Spectrograph (IRIS) spectral and slit-jaw observations of a quiet region near the South Pole. In this article we present an overview of the observations, the corrections, and the absolute calibration of the intensity. We focus on the average profiles of strong (Mg ii h and k, C ii and Si iv), as well as of weak spectral lines in the near ultraviolet (NUV) and the far ultraviolet (FUV), including the Mg ii triplet, thus probing the solar atmosphere from the low chromosphere to the transition region. We give the radial variation of bulk spectral parameters as well as line ratios and turbulent velocities. We present measurements of the formation height in lines and in the NUV continuum from which we find a linear relationship between the position of the limb and the intensity scale height. We also find that low forming lines, such as the Mg ii triplet, show no temporal variations above the limb associated with spicules, suggesting that such lines are formed in a homogeneous atmospheric layer and, possibly, that spicules are formed above the height of 2''. We discuss the spatio-temporal structure of the atmosphere near the limb from images of intensity as a function of position and time. In these images, we identify p-mode oscillations in the cores of lines formed at low heights above the photosphere, slow-moving bright features in O i and fast-moving bright features in C ii. Finally, we compare the Mg ii k and h line profiles, together with intensity values of the Balmer lines from the literature, with computations from the PROM57Mg non-LTE model, developed at the Institut d' Astrophysique Spatiale, and estimated values of the physical parameters. We obtain electron temperatures in the range of {˜} 8000 K at small heights to {˜} 20 000 K at large heights, electron densities from 1.1× 10^{11} to 4× 10^{10} cm^{-3} and a turbulent velocity of {˜} 24 km s^{-1}.

  16. Seismic Observations in Extreme Cold Environments: IRIS Instrumentation Takes to the Cold

    Science.gov (United States)

    Fowler, J.; Anderson, K. R.; Parker, T.; Beaudoin, B. C.; Bonnett, B.

    2007-12-01

    In 2006, the National Science Foundation (NSF) awarded a Major Research Initiative (MRI) grant to UNAVCO and the Incorporated Research Institutions for Seismology (IRIS) to develop a power and communications system that will improve remote autonomous geophysical observations in the polar environments. Currently in the second year of a three year program, field developments and designs have proven that a high-quality seismic station can be operated and maintained in an extremely cold environment utilizing recent manufacturing breakthroughs in light weight battery designs and insulating materials. With modern, state-of-the-art seismic equipment now being designed to operate at very low power in more extreme temperature ranges, we have the opportunity to exploit new opportunities in polar environments with increased reliability and reduced logistics requirements on the polar field support agencies (primarily, the NSF's Office of Polar Programs). As a result of intermediate results and successes with the autonomous station design, NSF has awarded another grant to IRIS to begin to establish a pool of seismic instrumentation and station infrastructure packages designed to operate PASSCAL experiments in the polar-regions. Procurement has begun on this new pool and support of field operations have already begun on projects in Greenland (Helheim Glacier) and Antarctica (Gamburtsev Mountains Project - AGAP; Polenet; and a tomographic study of Mt Erebus). Along with the equipment, PASSCAL has now established a dedicated staff to polar projects to further enhance the support and quality of the data return for these challenging projects.

  17. Plateau iris Íris em platô

    Directory of Open Access Journals (Sweden)

    Alberto Diniz Filho

    2008-10-01

    Full Text Available The term plateau iris was first coined in 1958 to describe the iris configuration of a patient. Two years later the concept of plateau iris was published. In 1977, the plateau iris configuration was classically defined as presurgical changes of an eye with a relative normal central anterior chamber depth, flat iris by conventional biomicroscopy, but displaying an extremely narrow or closed angle on gonioscopic examination. On the other hand, the plateau iris syndrome was defined as an acute glaucoma crisis in one eye with a relative normal central anterior chamber depth and patent iridotomy on direct examination, presenting angle closure confirmed by gonioscopic examination after mydriasis. In 1992, the anatomic aspects of plateau iris were studied using ultrasound biomicroscopy. Finally, plateau iris has been considered an anatomic variant of iris structure in which the iris periphery angulates sharply forward from its insertion point and then again angulates sharply and centrally backward, along with an anterior positioning of the ciliary processes seen on ultrasound biomicroscopy. The clinical treatment of plateau iris syndrome is carried out with topical use of pilocarpine. However, the definitive treatment should be fulfilled by performing an argon laser peripheral iridoplasty.O termo íris em platô foi primeiramente inventado em 1958 para descrever a configuração da íris de um paciente. Dois anos depois o conceito de íris em platô foi publicado. Em 1977, a configuração de íris em platô foi classicamente definida como alterações pré-cirúrgicas de um olho com uma profundidade de câmara anterior relativamente normal, íris plana pela biomicroscopia convencional, mas mostrando um ângulo extremamente estreito ou fechado pela gonioscopia. Por outro lado, a síndrome de íris em platô foi definida como uma crise de glaucoma agudo em um olho com uma profundidade de câmara anterior relativamente normal e uma iridectomia patente ao

  18. Fuel burnup analysis for IRIS reactor using MCNPX and WIMS-D5 codes

    Science.gov (United States)

    Amin, E. A.; Bashter, I. I.; Hassan, Nabil M.; Mustafa, S. S.

    2017-02-01

    International Reactor Innovative and Secure (IRIS) reactor is a compact power reactor designed with especial features. It contains Integral Fuel Burnable Absorber (IFBA). The core is heterogeneous both axially and radially. This work provides the full core burn up analysis for IRIS reactor using MCNPX and WIMDS-D5 codes. Criticality calculations, radial and axial power distributions and nuclear peaking factor at the different stages of burnup were studied. Effective multiplication factor values for the core were estimated by coupling MCNPX code with WIMS-D5 code and compared with SAS2H/KENO-V code values at different stages of burnup. The two calculation codes show good agreement and correlation. The values of radial and axial powers for the full core were also compared with published results given by SAS2H/KENO-V code (at the beginning and end of reactor operation). The behavior of both radial and axial power distribution is quiet similar to the other data published by SAS2H/KENO-V code. The peaking factor values estimated in the present work are close to its values calculated by SAS2H/KENO-V code.

  19. An Investigation of Non-Thesis Master's Program Geography Teacher Candidates' Attitudes towards Teaching Profession regarding Several Socio-Cultural Features

    Science.gov (United States)

    Sezer, Adem; Kara, Hasan; Pinar, Adnan

    2011-01-01

    The purpose of this study is to examine the attitudes of non-thesis master's degree program: geography teacher candidates towards teaching profession regarding several socio-cultural features. The study was conducted in different universities with 218 geography teacher candidates enrolled in the geography education non-thesis master's degree…

  20. Features of parallel processing of Russian language content using the basic characteristics of object-oriented high-level programming languages

    Directory of Open Access Journals (Sweden)

    Дмитрий Евгеньевич Кошкин

    2013-12-01

    Full Text Available The article discusses the general features which are traceable in the Russian language and high-level programming languages, and offers an approach to identify the relationship between words in a sentence and proposals within the text. A matter may be interesting in terms of automatic semantic analysis of texts and for the systems of automatic translation.

  1. Daffodil flower delay senescence in cut Iris flowers

    NARCIS (Netherlands)

    Doorn, van W.G.; Sinz, A.; Tomassen, M.M.M.

    2004-01-01

    Visible symptoms of tepal senescence in cut Iris x hollandica (cv. Blue Magic) flowers were delayed by placing one cut daffodil flower (Narcissus pseudonarcissus, cv. Carlton) in the same vase. Addition of mucilage, exuded by daffodil stems, to the vase water had the same effect as the flowering

  2. In Vitro Antimicrobial Activity of Iris pseudacorus and Urtica dioica

    Directory of Open Access Journals (Sweden)

    Maryam Ramtin

    2014-03-01

    Full Text Available Background: In this study, the effects of antibacterial activity of Urtica dioica and Iris pseudacorus essential oils, native plant northern of Iran, were investigated for some selected bacteria. Material and Methods: The influence of essential oils was tested by the using of disk diffusion and micro-broth dilution methods against standard strains of the picked out bacteria. Gas Chromatography/Mass Spectroscopy (GC/MS analysis, bioactivity determination, Minimum inhibitory concentrations (MIC and minimum bactericidal concentration (MBC of essential oils were utilized for this goal. Results: This study showed that, Inhibition zone diameter varied from 11 to 19 mm and 9 to 17 mm for Urtica dioica and Iris pseudacorus respectively. In contrast, this figure fluctuated from 19 to 28 mm and 7 to 17 mm for gentamicin and ampicillin separately. By the application of micro-broth dilution technique, MICs for 1% essential oils were 1.8-7.5 μg/ml and 3.75-15 μg/ml for, Urtica dioica and Iris pseudacorus against gram-positive and gram-negative bacteria individually. Furthermore, the MBCs of herbal essences were 1.8-15 μg/ml for, Urtica dioica and 15-30 μg/ml for Iris. Conclusion: The application of essential oils for the bio-control of diseases, as a novel emerging alternative to antimicrobial treatments, lead to safer and more environmental management for infective diseases4T.4T

  3. Epigenetic randomness, complexity and singularity of human iris patterns

    National Research Council Canada - National Science Library

    John Daugman; Cathryn Downing

    2001-01-01

    .... The resulting diversity, and the combinatorial complexity created by so many dimensions of random variation, mean that the failure of a simple test of statistical independence performed on iris patterns can serve as a reliable rapid basis for automatic personal identification.

  4. Preface: The International Reference Ionosphere (IRI) at equatorial latitudes

    Science.gov (United States)

    Reinisch, Bodo; Bilitza, Dieter

    2017-07-01

    This issue of Advances in Space Research includes papers that report and discuss improvements of the International Reference Ionosphere (IRI). IRI is the international standard for the representation of the plasma in Earth's ionosphere and recognized as such by the Committee on Space Research (COSPAR), the International Union of Radio Science (URSI), the International Telecommunication Union (ITU), and the International Standardization Organization (ISO). As requested, particularly by COSPAR and URSI, IRI is an empirical model relying on most of the available and reliable ground and space observations of the ionosphere. As new data become available and as older data sources are fully exploited the IRI model undergoes improvement cycles to stay as close to the existing data record as possible. The latest episode of this process is documented in the papers included in this issue using data from the worldwide network of ionosondes, from a few of the incoherent scatter radars, from the Alouette and ISIS topside sounders, and from the Global Navigation Satellite Systems (GNSS). The focus of this issue is on the equatorial and low latitude region that is of special importance for ionospheric physics because it includes the largest densities and steep density gradients in the double hump latitudinal structure, the Equatorial Ionization Anomaly (EIA), which is characteristic for this region.

  5. Comparison of ionospheric radio occultation CHAMP data with IRI 2001

    Directory of Open Access Journals (Sweden)

    N. Jakowski

    2004-01-01

    Full Text Available GPS radio occultation measurements on board low Earth orbiting satellites can provide vertical electron density profiles of the ionosphere from satellite orbit heights down to the bottomside. Ionospheric radio occultation (IRO measurements carried out onboard the German CHAMP satellite mission since 11 April 2001 were used to derive vertical electron density profiles (EDP’s on a routine basis. About 150 vertical electron density profiles may be retrieved per day thus providing a huge data basis for testing and developing ionospheric models. Although the validation of the EDP retrievals is not yet completed, the paper addresses a systematic comparison of about 78 000 electron density profiles derived from CHAMP IRO data with the International Reference Ionosphere (IRI 2001. The results are discussed for quite different geophysical conditions, e.g. as a function of latitude, local time and geomagnetic activity. The comparison of IRO data with corresponding IRI data indicates that IRI generally overestimates the upper part of the ionosphere whereas it underestimates the lower part of the ionosphere under high solar activity conditions. In a first order correction this systematic deviation could be compensated by introducing a height dependence correction factor in IRI profiling.

  6. Modeling the factors that influence behavioural intention to use Iris ...

    African Journals Online (AJOL)

    Study of technology adoption serves as a roadmap to the actual acceptance of the technology starting from the external factors to personal beliefs, intentions, adoption which finally leads to actual usage of the technology. The study aims at determining the factors that verify users' acceptance of iris-based authentication ...

  7. Indexing Iris Biometric Database Using Energy Histogram of DCT Subbands

    Science.gov (United States)

    Mehrotra, Hunny; Srinivas, Badrinath G.; Majhi, Banshidhar; Gupta, Phalguni

    The key concern of indexing is to retrieve small portion of database for searching the query. In the proposed paper iris database is indexed using energy histogram. The normalised iris image is divided into subbands using multiresolution DCT transformation. Energy based histogram is formed for each subband using all the images in the database. Each histogram is divided into fixed size bins to group the iris images having similar energy value. The bin number for each subband is obtained and all subands are traversed in Morton order to form a global key for each image. During database preparation the key is used to traverse the B tree. The images with same key are stored in the same leaf node. For a given query image, the key is generated and tree is traversed to end up to a leaf node. The templates stored at the leaf node are retrieved and compared with the query template to find the best match. The proposed indexing scheme is showing considerably low penetration rate of 0.63%, 0.06% and 0.20% for CASIA, BATH and IITK iris databases respectively.

  8. IRIS Toxicological Review of Acrylamide (External Review Draft)

    Science.gov (United States)

    EPA has conducted a peer review by EPA’s Science Advisory Board (SAB) of the scientific basis supporting the human health hazard and dose-response assessment of acrylamide that once finalized will appear on the Integrated Risk Information System (IRIS) database. Peer review is m...

  9. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Directory of Open Access Journals (Sweden)

    Garcia-Rojas Leonardo

    2012-10-01

    Full Text Available Abstract Background To assess the efficacy, clinical outcomes, visual acuity (VA, incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%, 20/60 or better in 12 eyes (92%, and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method.

  10. The IRIS Network of Excellence: Future Directions in Interactive Storytelling

    Science.gov (United States)

    Cavazza, Marc; Champagnat, Ronan; Leonardi, Riccardo

    The IRIS Network of Excellence started its work in January 2009. In this paper we highlight some new research directions developing within the network: one is revisiting narrative formalisation through the use of Linear Logic and the other is challenging the conventional framework of basing Interactive Storytelling on computer graphics to explore the content-based recombination of video sequences.

  11. Case Report: Bilateral iris, choroid, optic nerve colobomas and ...

    African Journals Online (AJOL)

    Background: Baraitser–Winter syndrome (BRWS) is a malformation syndrome, characterized by facial dysmorphism, ocular colobomata, pachygyria, and intellectual defects. Case report: A 3.5 year old female child with BRWS has bilateral congenital ptosis, microcornea, iris, choroid, and optic nerve coloboma, retinal ...

  12. Delay of Iris flower senescence by protease inhibitors

    NARCIS (Netherlands)

    Pak, C.; Doorn, van W.G.

    2005-01-01

    asterisk inside a circle sign Visible senescence of the flag tepals in Iris x hollandica (cv. Blue Magic) was preceded by a large increase in endoprotease activity. Just before visible senescence about half of total endoprotease activity was apparently due to cysteine proteases, somewhat less than

  13. Transillumination of iris and subnormal visual acuity--ocular albinism?

    Science.gov (United States)

    Sjödell, L; Sjöström, A; Abrahamsson, M

    1996-07-01

    A common clinical sign in children with subnormal visual acuity or slow visual development was iris transillumination. This was used as the inclusion criterion in a study of children shown to have a subnormal visual acuity in a general health examination at age 4 years. Refraction values, stereopsis, fundus photography, macular and nerve head appearance, and visual evoked response (VER) recordings were studied in 18 children. The clinical results were compared with 64 controls referred to the eye clinic because of subnormal vision from the general health examination or from school health care. Eight children had VERs showing asymmetry typical for albinism. Another four had only small asymmetries on the VER, indicating a lower degree of decussation abnormality. No simple correlation of visual acuity, degree of iris transillumination, stereopsis, or macular pathology and VER asymmetries were found. However, marked iris transillumination in all four quadrants, absence of a foveal reflex, and low visual acuity were weakly correlated. In a rather homogeneous group of children with iris transillumination and subnormal visual acuity eight of 18 had typical albino VERs. The findings of small atypical VER asymmetries in four children and no asymmetry in six children suggest that albinism may be considered as a description of a heterogeneous group of conditions including maximal decussation rate (100%) in the chiasma to a condition with almost normal (> or = 50%) decussation rate.

  14. IRIS Toxicological Review of Methanol (External Review Draft, 2013)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  15. IRIS Toxicological Review of Methanol (Noncancer) (Interagency Science Discussion Draft)

    Science.gov (United States)

    On May 3, 2013, the Toxicological Review of Methanol (noncancer) (Revised External Review Draft) was posted for public review and comment. Subsequently, the draft Toxicological Review, Appendices, and draft IRIS Summary were reviewed internally by EPA and by other federal agenci...

  16. Bilateral iris, choroid, optic nerve colobomas and retinal detachment ...

    African Journals Online (AJOL)

    Rabah M. Shawky

    2013-12-05

    Dec 5, 2013 ... tural changes can cause mild to severe intellectual disability, developmental delay, and convulsions [2]. ... high-arched eyebrows, mental retardation, and multiple malfor- mations also involving the brain. .... disabilities in 100%, hearing loss in 83.3%, iris or retinal coloboma in 71.4%, and seizers in 87.5% of ...

  17. Security enhanced BioEncoding for protecting iris codes

    Science.gov (United States)

    Ouda, Osama; Tsumura, Norimichi; Nakaguchi, Toshiya

    2011-06-01

    Improving the security of biometric template protection techniques is a key prerequisite for the widespread deployment of biometric technologies. BioEncoding is a recently proposed template protection scheme, based on the concept of cancelable biometrics, for protecting biometric templates represented as binary strings such as iris codes. The main advantage of BioEncoding over other template protection schemes is that it does not require user-specific keys and/or tokens during verification. Besides, it satisfies all the requirements of the cancelable biometrics construct without deteriorating the matching accuracy. However, although it has been shown that BioEncoding is secure enough against simple brute-force search attacks, the security of BioEncoded templates against more smart attacks, such as record multiplicity attacks, has not been sufficiently investigated. In this paper, a rigorous security analysis of BioEncoding is presented. Firstly, resistance of BioEncoded templates against brute-force attacks is revisited thoroughly. Secondly, we show that although the cancelable transformation employed in BioEncoding might be non-invertible for a single protected template, the original iris code could be inverted by correlating several templates used in different applications but created from the same iris. Accordingly, we propose an important modification to the BioEncoding transformation process in order to hinder attackers from exploiting this type of attacks. The effectiveness of adopting the suggested modification is validated and its impact on the matching accuracy is investigated empirically using CASIA-IrisV3-Interval dataset. Experimental results confirm the efficacy of the proposed approach and show that it preserves the matching accuracy of the unprotected iris recognition system.

  18. Design and performance of a cryogenic iris aperture mechanism

    Science.gov (United States)

    de Jonge, C.; Laauwen, W. M.; de Vries, E. A.; Smit, H. P.; Detrain, A.; Eggens, M. J.; Ferrari, L.; Dieleman, P.

    2014-07-01

    A cryogenic iris mechanism is under development as part of the ground calibration source for the SAFARI instrument. The iris mechanism is a variable aperture used as an optical shutter to fine-tune and modulate the absolute power output of the calibration source. It has 4 stainless steel blades that create a near-circular aperture in every position. The operating temperature is 4.5 Kelvin to provide a negligible background to the SAFARI detectors, and `hot spots' above 9K should be prevented. Cryogenic testing proved that the iris works at 4K. It can be used in a broad range of cryogenic optical instruments where optical throughput needs to be controlled. Challenges in the design include the low cooling power available (5mW) and low friction at cryogenic temperatures. The actuator is an `arc-type' rotary voice-coil motor. The use of flexural pivots creates a mono-stable mechanism with a resonance frequency at 26Hz. Accurate and fast position control with disturbance rejection is managed by a PID servo loop using a hall-sensor as input. At 4 Kelvin, the frequency is limited to 4Hz to avoid excess dissipation and heating. In this paper, the design and performance of the iris are discussed. The design was optimized using a thermal, magnetic and mechanical model made with COMSOL Finite Element Analysis software. The dynamical and state-space modeling of the mechanism and the concept of the electrical control are presented. The performance of the iris show good agreement to the analytical and COMSOL modeling.

  19. Morphologic alterations on posterior iris-claw intraocular lenses after traumatic disenclavation.

    Science.gov (United States)

    Brockmann, Tobias; Gonnermann, Johannes; Brockmann, Claudia; Torun, Necip; Joussen, Antonia M; Bertelmann, Eckart

    2014-09-01

    To analyse morphologic alterations on posterior iris-claw intraocular lenses (IOL) after dislocation due to traumatic disenclavation. Seven dislocated iris-claw IOLs were included in this observational study. Five posterior iris-claw IOLs were explanted after traumatic disenclavation and compared to two iris-claw IOLs with a history of spontaneous disenclavation. One original aphakic iris-claw IOL served as control. All IOLs underwent standardised examinations using light microscopy. All traumatically disenclaved iris-claw haptics presented decentred and twisted fixation arms. The average decentration on iris-claw haptics measured 23±11 µm in the surface plane and 103±43 µm on the edge profile; the axial twist of the fixation arms measured five angular degrees. Traumatically affected haptics were tilted (3/5) or did not provide an adequate closure (2/5), so that a reliable fixation on the iris stroma was not ensured. Morphologic alterations were significantly different after traumatic and spontaneous disenclavation. Spontaneously disenclaved IOLs and the original IOL demonstrated symmetric haptics with centred iris-claws and a sufficient closure. Traumatically dislocated iris-claw IOLs presented considerable alterations on the affected haptics, which might not guarantee a reliable re-enclavation. Therefore, we suggest an IOL replacement, instead of reenclavation, in cases of traumatic iris-claw disenclavation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Iris Segmentation using Gradient Magnitude and Fourier Descriptor for Multimodal Biometric Authentication System

    Directory of Open Access Journals (Sweden)

    Defiana Sulaeman

    2016-12-01

    Full Text Available Perfectly segmenting the area of the iris is one of the most important steps in iris recognition. There are several problematic areas that affect the accuracy of the iris segmentation step, such as eyelids, eyelashes, glasses, pupil (due to less accurate iris segmentation, motion blur, and lighting and specular reflections. To solve these problems, gradient magnitude and Fourier descriptor are employed to do iris segmentation in the proposed Multimodal Biometric Authentication System (MBAS. This approach showed quite promising results, i.e. an accuracy rate of 97%. The result of the iris recognition system was combined with the result of an open-source fingerprint recognition system to develop a multimodal biometrics authentication system. The results of the fusion between iris and fingerprint authentication were 99% accurate. Data from Multimedia Malaysia University (MMUI and our own prepared database, the SGU-MB-1 dataset, were used to test the accuracy of the proposed system.

  1. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    Science.gov (United States)

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  2. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma.

    Science.gov (United States)

    Mizoguchi, Takanori; Ozaki, Mineo; Wakiyama, Harumi; Ogino, Nobuchika

    2015-01-01

    To determine the prevalence of plateau iris in Japanese patients with primary angle closure (PAC) and primary angle closure glaucoma (PACG) and analyze the biometric parameters in patients with plateau iris using ultrasound biomicroscopy (UBM). In this cross-sectional observational study, subjects aged >50 years with PAC and PACG who had previously undergone a patent laser peripheral iridotomy underwent UBM in one eye. UBM images were qualitatively analyzed using standardized criteria. Plateau iris in a quadrant was defined by anteriorly directed ciliary body, absent ciliary sulcus, steep iris root from its point of insertion followed by a downward angulation, flat iris plane, and irido-angle contact. At least two quadrants had to fulfill these UBM criteria for an eye to be classified as having plateau iris. A-scan biometry was used to measure anterior segment parameters. Ninety-one subjects with PAC (58 subjects) or PACG (33 subjects) and 68 normal controls were recruited. The mean (standard deviation) ages of PAC and PACG patients and normal controls were 73.5 (6.2) and 72.6 (7.3), respectively. Based on UBM criteria, plateau iris was found in 16 eyes (17.6%) of 91 eyes. In these 16 eyes, quadrant-wise analysis showed ten eyes (62.5%) had plateau iris in two quadrants; four eyes (25%) had plateau iris in three quadrants; and two eyes (12.5%) had plateau iris in four quadrants. Anterior chamber depth, lens thickness, axial length, lens position, and relative lens position were not statistically significant between the group having plateau iris and that not having plateau iris, respectively. Approximately 20% of Japanese subjects with PAC and PACG with a patent laser peripheral iridotomy were found to have plateau iris on UBM. No morphological difference was noted in the anterior segment of the eye between those with or without plateau iris.

  3. Vesicles between plasma membrane and cell wall prior to visible senescence of Iris and Dendrobium flowers.

    Science.gov (United States)

    Kamdee, Channatika; Kirasak, Kanjana; Ketsa, Saichol; van Doorn, Wouter G

    2015-09-01

    Cut Iris flowers (Iris x hollandica, cv. Blue Magic) show visible senescence about two days after full opening. Epidermal cells of the outer tepals collapse due to programmed cell death (PCD). Transmission electron microscopy (TEM) showed irregular swelling of the cell walls, starting prior to cell collapse. Compared to cells in flowers that had just opened, wall thickness increased up to tenfold prior to cell death. Fibrils were visible in the swollen walls. After cell death very little of the cell wall remained. Prior to and during visible wall swelling, vesicles (paramural bodies) were observed between the plasma membrane and the cell walls. The vesicles were also found in groups and were accompanied by amorphous substance. They usually showed a single membrane, and had a variety of diameters and electron densities. Cut Dendrobium hybrid cv. Lucky Duan flowers exhibited visible senescence about 14 days after full flower opening. Paramural bodies were also found in Dendrobium tepal epidermis and mesophyll cells, related to wall swelling and degradation. Although alternative explanations are well possible, it is hypothesized that paramural bodies carry enzymes involved in cell wall breakdown. The literature has not yet reported such bodies in association with senescence/PCD. Copyright © 2015 Elsevier GmbH. All rights reserved.

  4. Management of dislocated intraocular lenses with iris suture.

    Science.gov (United States)

    Faria, Mun Y; Ferreira, Nuno P; Canastro, Mario

    2017-01-19

    Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of log

  5. Genetic Programming and Frequent Itemset Mining to Identify Feature Selection Patterns of iEEG and fMRI Epilepsy Data.

    Science.gov (United States)

    Smart, Otis; Burrell, Lauren

    2015-03-01

    Pattern classification for intracranial electroencephalogram (iEEG) and functional magnetic resonance imaging (fMRI) signals has furthered epilepsy research toward understanding the origin of epileptic seizures and localizing dysfunctional brain tissue for treatment. Prior research has demonstrated that implicitly selecting features with a genetic programming (GP) algorithm more effectively determined the proper features to discern biomarker and non-biomarker interictal iEEG and fMRI activity than conventional feature selection approaches. However for each the iEEG and fMRI modalities, it is still uncertain whether the stochastic properties of indirect feature selection with a GP yield (a) consistent results within a patient data set and (b) features that are specific or universal across multiple patient data sets. We examined the reproducibility of implicitly selecting features to classify interictal activity using a GP algorithm by performing several selection trials and subsequent frequent itemset mining (FIM) for separate iEEG and fMRI epilepsy patient data. We observed within-subject consistency and across-subject variability with some small similarity for selected features, indicating a clear need for patient-specific features and possible need for patient-specific feature selection or/and classification. For the fMRI, using nearest-neighbor classification and 30 GP generations, we obtained over 60% median sensitivity and over 60% median selectivity. For the iEEG, using nearest-neighbor classification and 30 GP generations, we obtained over 65% median sensitivity and over 65% median selectivity except one patient.

  6. Dementia and the biopolitics of the biopic: from Iris to The iron lady.

    Science.gov (United States)

    Wearing, Sadie

    2013-05-01

    This article considers the question of embodiment through a comparative analysis of two 'biopics', Iris (2001) and The Iron Lady (2011), which both feature eponymous characters that have, or had, dementia. Embodiment draws our attention to the representation of the body in the films themselves, and to the socially significant 'feelings' or affects that circulate within and are reproduced around them. Shame, disgust and aversion are socially devastating affects conventionally associated with stigmatised bodies including those of the cognitively impaired but attention to the 'feeling tone' (Ngai, 2005) in these films demonstrates that a more varied range of affects and embodied social knowledge is produced. Embodiment is thus a starting point to explore what is at stake in these films both in their authorisation of particular versions of public lives and for their significance for the cultural politics of representation in the context of explorations of personhood and dementia.

  7. Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.

    Science.gov (United States)

    Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan

    2017-09-05

    To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.

  8. Design and implementation of an algorithm for creating templates for the purpose of iris biometric authentication through the analysis of textures implemented on a FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Giacometto, F J; Vilardy, J M; Torres, C O; Mattos, L, E-mail: franciscogiacometto@unicesar.edu.co [Laboratorio de Optica e Informatica, Universidad Popular del Cesar, Sede balneario Hurtado, Valledupar, Cesar (Colombia)

    2011-01-01

    Currently addressing problems related to security in access control, as a consequence, have been developed applications that work under unique characteristics in individuals, such as biometric features. In the world becomes important working with biometric images such as the liveliness of the iris which are for both the pattern of retinal images as your blood vessels. This paper presents an implementation of an algorithm for creating templates for biometric authentication with ocular features for FPGA, in which the object of study is that the texture pattern of iris is unique to each individual. The authentication will be based in processes such as edge extraction methods, segmentation principle of John Daugman and Libor Masek's, and standardization to obtain necessary templates for the search of matches in a database and then get the expected results of authentication.

  9. Design and implementation of an algorithm for creating templates for the purpose of iris biometric authentication through the analysis of textures implemented on a FPGA

    Science.gov (United States)

    Giacometto, F. J.; Vilardy, J. M.; Torres, C. O.; Mattos, L.

    2011-01-01

    Currently addressing problems related to security in access control, as a consequence, have been developed applications that work under unique characteristics in individuals, such as biometric features. In the world becomes important working with biometric images such as the liveliness of the iris which are for both the pattern of retinal images as your blood vessels. This paper presents an implementation of an algorithm for creating templates for biometric authentication with ocular features for FPGA, in which the object of study is that the texture pattern of iris is unique to each individual. The authentication will be based in processes such as edge extraction methods, segmentation principle of John Daugman and Libor Masek's, and standardization to obtain necessary templates for the search of matches in a database and then get the expected results of authentication.

  10. Brain responses to language-relevant musical features in adolescent cochlear implant users before and after an intensive music training program

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Weed, Ethan; Hansen, Mads

    Brain responses to language-relevant musical features in adolescent cochlear implant users before and after an intensive music training program Petersen B.1,2, Weed E.1,3, Hansen M.1,4, Sørensen S.D.3 , Sandmann P.5 , Vuust P.1,2 1Center of Functionally Integrative Neuroscience, Aarhus University...... musical training. The finding points toward the possibility of improving appreciation of music in general for adolescent CI users, and using music as a motivating element in speech therapy programs....

  11. Locating An IRIS From Image Using Canny And Hough Transform

    Directory of Open Access Journals (Sweden)

    Poorvi Bhatt

    2017-11-01

    Full Text Available Iris recognition a relatively new biometric technology has great advantages such as variability stability and security thus it is the most promising for high security environments. The proposed system here is a simple system design and implemented to find the iris from the image using Hough Transform Algorithm. Canny Edge detector has been used to get edge image to use it as an input to the Hough Transform. To get the general idea of Hough Transform the Hough Transform for circle is also implemented. RGB value of 3-D accumulator array of peaks of inner circle and outer circle has been performed. And at the end some suggestions are made to improve the system and performance gets discussed.

  12. Boimsja togo, tshego ne znajem / Iris Pettai ; interv. Nelli Kuznetsova

    Index Scriptorium Estoniae

    Pettai, Iris, 1947-

    2004-01-01

    Presidendi juures asuva vähemusrahvuste ümarlaua ning poliitikute ja ekspertide kohtumisel esinenud sotsioloogi Iris Pettai hinnangul on riigile ohtlik, kui kaks kogukonda elavad paralleelselt, puutuvad vähe kokku. Mida väiksem on sallivus või tolerantsus põhirahva hulgas, seda rohkem tõukab ta ühiskonnast eemale teistest rahvustest inimesi. Sallivuse viiest arengufaasist

  13. Incorporation of topside half peak density anchor point in IRI

    Science.gov (United States)

    Gulyaeva, T. L.

    2004-01-01

    The F2 layer peak density ( N mF2) and height ( h mF2) are used by the International Reference Ionosphere as anchor point fitted by the electron density profile. The shape of the bottomside Ne( h) distribution is formulated with the help of profile sub-peak semithickness taken as a distance between the peak height and the bottom half-peak density height h05 bot. In a similar manner relevant procedure allowing to fit IRI topside electron density profile to additional anchor point — the half-peak density height h05 top at electron density equal to 0.5 × N mF2 above the F2 peak is included in the IRI ionosphere-plasmasphere model. Two types of :input are used with IRI code for 14 intense magnetic storms during 1999-2003: ionosonde derived data ( ƒoF2, h mF2 and hO5 bot) and Global Positioning System (GPS)-based total electron content (TEC) observation. It is shown that topside half-peak height h05 top and topside scale height can be inferred from the GPS-TEC measurements with an iteration procedure applied to IRI profiling algorithm. The proposed technique is validated with incoherent scatter ionospheric electron content, ITEC, provided by EISCAT electron density profiles. Good correlation is obtained between the height h05 top and the equivalent slab thickness τ, representing ratio of TEC to N mF2. This approach allowed us to reveal a highly variable topside scale height for intense space weather storms at mid latitudes with peaks up to 800 km during the peaks of magnetic activity.

  14. PSYCHOLOGICAL FEATURES IN PATIENTS WITH CORONARY HEART DISEASE (MEN AND WOMEN PRIOR TO CORONARY ARTERY BYPASS GRAFTING DEPENDING ON THEIR INVOLVEMENT IN THE INDIVIDUAL PSYCHO-CORRECTION PROGRAM

    Directory of Open Access Journals (Sweden)

    D. A. Starunskaya

    2017-01-01

    Full Text Available Importance. The study of psychological characteristics of patients is important for the creation and planning of psychological correction and improve the efficiency of the treatment of coronary heart disease.Тhe purpose. This research is devoted to the study of the psychological features in patients with coronary artery disease (CHD in the preoperative period, depending on their involvement in psycho-correction program.Material and methods. We observed 30 patients with coronary heart disease before coronary bypass surgery. Clinical-psychological method (observation, conversation and psychological testing were used.Results  and conclusions. We found that patients who participated in psycho-correction program had lower values of «anxiety», «phobic anxiety» and «obsessive-compulsive» symptoms. In both groups of patients, on average, we identified the prevalence  of the coping-strategies «self-control» and «planning solution». Furthermore, on average, the «self-awareness» and «extraversion» were more manifested features in the structure of the personality traits of the surveyed patients. The revealed features should be taken into account in planning the programs of psycho-correction for patients with CHD prior to CABG surgery.

  15. Assessment of IRI-2012, NeQuick-2 and IRI-Plas 2015 models with observed equatorial ionization anomaly in Africa during 2009 sudden stratospheric warming event

    Science.gov (United States)

    Bolaji, O. S.; Oyeyemi, E. O.; Adewale, A. O.; Wu, Q.; Okoh, D.; Doherty, P. H.; Kaka, R. O.; Abbas, M.; Owolabi, C.; Jidele, P. A.

    2017-11-01

    In Africa, we assessed the performance of all the three options of International Reference Ionosphere 2012, IRI-2012 (i.e. IRI-2001, IRI-2001COR and IRI-NeQuick), NeQuick-2 and IRI-Plas 2015 models prior to and during 2009 sudden stratospheric warming (SSW) event to predict equatorial ionization anomaly (EIA) crest locations and their magnitudes using total electron content (TEC) from experimental records of Global Positioning System (GPS). We confirmed that the IRI-Plas 2015 that appeared as the best compared to all of the models as regard prediction of the EIA crest locations in the northern hemisphere of Africa is due to discontinuities in the GPS data between ∼8° N and 22° N. As regard the predictions of EIA crest magnitudes and the location of EIA crests in the southern hemisphere of Africa, they are not present in all the models. The NeQuick-2 model does not have the capability to predict either the EIA crest location in the northern or southern hemisphere. The SSW effect on the low latitude was able to modify a single EIA crest to pre-noon and post noon EIA crests in the northern hemisphere during the SSW peak phase and significantly reduced the GPS TEC magnitudes over the hemispheres as well. These SSW effects and delays of plasma transportation to higher latitudes in GPS TEC were absent in all the models. For future improvements of IRI-2012, NeQuick-2 and IRI-Plas 2015 models, SSW conditions should be included in order to characterize the effect of lower atmosphere on the ionosphere. The EIA trough modeling is only present in IRI-2001COR and IRI-2001NeQuick options. In the middle latitude, all the model could not predict the location of highest TEC magnitudes found at RBAY (Richardsbay, South Africa).

  16. Prominence and tornado dynamics observed with IRIS and THEMIS

    Science.gov (United States)

    Schmieder, Brigitte; Levens, Peter; Labrosse, Nicolas; Mein, Pierre; Lopez Ariste, Arturo; Zapior, Maciek

    2017-08-01

    Several prominences were observed during campaigns in September 2013 and July 2014 with the IRIS spectrometer and the vector magnetograph THEMIS (Tenerife). SDO/AIA and IRIS provided images and spectra of prominences and tornadoes corresponding to different physical conditions of the transition region between the cool plasma and the corona. The vector magnetic field was derived from THEMIS observations by using the He D3 depolarisation due to the magnetic field. The inversion code (PCA) takes into account the Hanle and Zeeman effects and allows us to compute the strength and the inclination of the magnetic field which is shown to be mostly horizontal in prominences as well as in tornadoes. Movies from SDO/AIA in 304 A and Hinode/SOT in Ca II show the highly dynamic nature of the fine structures. From spectra in Mg II and Si IV lines provided by IRIS and H-alpha observed by the Multi-channel Subtractive Double Pass (MSDP) spectrograph in the Meudon Solar Tower we derived the Doppler shifts of the fine structures and reconstructed the 3D structure of tornadoes. We conclude that the apparent rotation of AIA tornadoes is due to large-scale quasi-periodic oscillations of the plasma along more or less horizontal magnetic structures.

  17. LDPC and SHA based iris recognition for image authentication

    Directory of Open Access Journals (Sweden)

    K. Seetharaman

    2012-11-01

    Full Text Available We introduce a novel way to authenticate an image using Low Density Parity Check (LDPC and Secure Hash Algorithm (SHA based iris recognition method with reversible watermarking scheme, which is based on Integer Wavelet Transform (IWT and threshold embedding technique. The parity checks and parity matrix of LDPC encoding and cancellable biometrics i.e., hash string of unique iris code from SHA-512 are embedded into an image for authentication purpose using reversible watermarking scheme based on IWT and threshold embedding technique. Simply by reversing the embedding process, the original image, parity checks, parity matrix and SHA-512 hash are extracted back from watermarked-image. For authentication, the new hash string produced by employing SHA-512 on error corrected iris code from live person is compared with hash string extracted from watermarked-image. The LDPC code reduces the hamming distance for genuine comparisons by a larger amount than for the impostor comparisons. This results in better separation between genuine and impostor users which improves the authentication performance. Security of this scheme is very high due to the security complexity of SHA-512, which is 2256 under birthday attack. Experimental results show that this approach can assure more accurate authentication with a low false rejection or false acceptance rate and outperforms the prior arts in terms of PSNR.

  18. Core physics analysis of 100% MOX core in IRIS

    Energy Technology Data Exchange (ETDEWEB)

    Franceschini, Fausto [Westinghouse Electric Company LLC, Science and Technology Department, Pittsburgh, PA 15235 (United States)], E-mail: FranceF@westinghouse.com; Petrovic, Bojan [Georgia Institute of Technology, Nuclear and Radiological Engineering, G.W. Woodruff School, Atlanta, GA 30332-0405 (United States)

    2008-09-15

    International Reactor Innovative and Secure (IRIS) is an advanced small-to-medium-size (1000 MWt) Pressurized Water Reactor (PWR), targeting deployment around 2015. Its reference core design is based on the current Westinghouse UO{sub 2} fuel with less than 5% {sup 235}U, and the analysis has been previously completed confirming good performance for that case. The full MOX fuel core is currently under evaluation as one of the alternatives for the second wave of IRIS reactors. A full 3-D neutronic analysis has been performed to examine main core performance and safety parameters, such as critical boron concentration, peaking factors, discharge burnup, reactivity coefficients, shut-down margin, etc. In addition, the basis to perform load follow maneuvers via the Westinghouse innovative strategy MSHIM has been established. The enhanced moderation of the IRIS fuel lattice facilitates MOX core design, and all the obtained results are within the operational and safety limits considered thus confirming viability of this option from the reactor physics standpoint.

  19. Outcomes of Sutureless Iris-Claw Lens Implantation

    Science.gov (United States)

    Nowomiejska, Katarzyna; Moneta-Wielgoś, Joanna; Jünemann, Anselm G. M.

    2016-01-01

    Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation. Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing. Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2). The mean preoperative CDVA was 0.25 (SD 0.21). The final mean CDVA was 0.46 (SD 0.27). No hypotony or need for wound suturing was observed postoperatively. Mean postoperative refractive error was −0.27 Dsph (−3.87 Dsph to +2.85 Dsph; median 0.0, SD 1.28). The mean postoperative astigmatism was −1.82 Dcyl (min −0.25, max −5.5; median −1.25, SD 1.07). Postoperative complications were observed in 10 eyes. The most common complication was ovalization of the iris, which was observed in 8 eyes. The mean operation time was 35.9 min (min 11 min, max 79 min; median 34, SD 15.4). Conclusion. Retropupilary iris-claw intraocular lens (IOL) implantation with sutureless wound closing is an easy and fast method, ensuring good refractive outcome and a low risk of complication. The Haigis formula proved to be predictable in postoperative refraction. PMID:27642519

  20. Distinguishing carcinoid tumor from small cell carcinoma of the lung: correlating cytologic features and performance in the College of American Pathologists Non-Gynecologic Cytology Program.

    Science.gov (United States)

    Renshaw, Andrew A; Haja, Jennifer; Lozano, Richard L; Wilbur, David C

    2005-05-01

    The cytologic features of carcinoid tumor of the lung are well described. Nevertheless, some carcinoids may be difficult to distinguish from small cell carcinomas. To correlate the cytologic features of individual cases of carcinoid tumor of the lung in fine-needle aspiration specimens in the College of American Pathologists Non-Gynecologic Cytology Program with the frequency of misclassification as small cell carcinoma. We reviewed 1100 interpretations from 26 different cases of carcinoid tumor in lung fine-needle aspiration specimens in the College of American Pathologists Non-Gynecologic Cytology Program and correlated the cytologic features with the performance in the program. Cases were divided into those that were frequently misclassified as small cell carcinoma (at least 20% of the responses, 19 cases) and those that were infrequently misclassified as small cell carcinoma (cytologic features that might be responsible for misclassification as small cell carcinoma. All 7 cases that were infrequently misclassified consisted of numerous monotonous well-preserved tumor cells that were either entirely round or were a mixture of round and spindle-shaped cells. Six of 7 cases showed a prominent streaming vascular pattern with tumor cells attached to the endothelial cell core. In contrast, cases that were frequently misclassified had 1 of 6 patterns that were not seen in cases that were rarely misclassified. These 6 patterns were: (1) poorly preserved and pale-staining cells with fine chromatin and a suggestion of molding (5 cases); (2) numerous large, well-preserved, spindle-shaped cells (2 cases); (3) numerous cells varying markedly in both size and shape (both round and spindle-shaped cells), with a common finding of degenerated, smudgy, small round and spindle-shaped cells (9 cases); (4) hypocellular specimens (8 cases); (5) obscuration of cells by blood (2 cases); and (6) tumor cells present predominantly in groups, with few isolated cells (8 cases). In none of

  1. Information fusion in personal biometric authentication based on the iris pattern

    Science.gov (United States)

    Wang, Fenghua; Han, Jiuqiang

    2009-04-01

    Information fusion in biometrics has received considerable attention. This paper focuses on the application of information fusion techniques in iris recognition. To improve the reliability and accuracy of personal identification based on the iris pattern, this paper proposes the schemes of multialgorithmic fusion and multiinstance fusion. Multialgorithmic fusion integrates the improved phase algorithm and the DCT-based algorithm, and multiinstance fusion combines information from the left iris and the right iris of an individual. Both multialgorithmic fusion and multiinstance fusion are carried out at the matching score level and the support vector machine (SVM)-based fusion rule is utilized to generate fused scores for final decision. The experimental results on the noisy iris database UBIRIS demonstrate that the proposed fusion schemes can perform better than the single recognition systems, and further prove that information fusion techniques are feasible and effective to improve the accuracy and robustness of iris recognition especially under noisy conditions.

  2. New data products available at the IRIS DMC

    Science.gov (United States)

    Trabant, C. M.; Bahavar, M.; Hutko, A.; Karstens, R.

    2010-12-01

    The research supported by the raw data from the observatories of NSF's EarthScope project are having tremendous impact on our understanding of the structure and geologic history of North America, how and why earthquakes occur and many other areas of modern geophysics. The IRIS Data Management Center (DMC) is the primary access point for EarthScope/USArray data and has embarked on a new effort to produce higher-level data products beyond raw time series in order to assist the community in extracting the highest value possible from these data. These new products will serve many purposes: stepping-stones for future research projects, data visualizations, research result comparisons and compilation of unique data sets as well as outreach material. To ensure community involvement in the development of new products the requirements and priorities are reviewed and approved by the IRIS Data Products Working Group (DPWG). Many new products are now available at the IRIS DMC. These include two event based products generated in near real time. 1) USArray Ground Motion Visualizations, routinely generated animations showing the both the vertical and horizontal seismic wavefields sweeping across the USArray Transportable Array from earthquakes around the world. 2) Event Plots, a suite of figures automatically generated following all M6.0+ events which include phase aligned record sections, global body wave envelope stacks, regional network vespagrams and source-time functions. 3) Earth Model Collaboration, a new web repository for community-supplied regional and global tomography models with the ability to preview, request and compare models. 4) EARS, the EarthScope Automated Receiver Survey, developed at the University of South Carolina, aims to calculate crustal thickness and bulk crustal properties beneath USArray stations as well as many other broadband stations whose data are archived at the IRIS DMC. 5) Archiving and distribution of Princeton 3D SEM and 1D synthetic

  3. Eye movement identification based on accumulated time feature

    Science.gov (United States)

    Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua

    2017-06-01

    Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.

  4. Improved Iris Recognition through Fusion of Hamming Distance and Fragile Bit Distance.

    Science.gov (United States)

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2011-12-01

    The most common iris biometric algorithm represents the texture of an iris using a binary iris code. Not all bits in an iris code are equally consistent. A bit is deemed fragile if its value changes across iris codes created from different images of the same iris. Previous research has shown that iris recognition performance can be improved by masking these fragile bits. Rather than ignoring fragile bits completely, we consider what beneficial information can be obtained from the fragile bits. We find that the locations of fragile bits tend to be consistent across different iris codes of the same eye. We present a metric, called the fragile bit distance, which quantitatively measures the coincidence of the fragile bit patterns in two iris codes. We find that score fusion of fragile bit distance and Hamming distance works better for recognition than Hamming distance alone. To our knowledge, this is the first and only work to use the coincidence of fragile bit locations to improve the accuracy of matches.

  5. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography.

    Science.gov (United States)

    Chen, Yu-Yen; Chu, Dachen; Chou, Pesus

    2015-01-01

    To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy. In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes. The normal controls, plateau iris group and pupillary block group were significantly different in age, but not in gender. The anterior chamber depth tended to decrease and the lens thickness tended to increase from normal to plateau iris to pupillary block eyes. Compared to those of plateau iris group, the pupillary block group had significantly shallower anterior chamber depth (2.90mm vs. 2.33mm; piris and normal eyes, only axial length and lens/axial length factor were significantly different (23.16 vs. 23.54; pbiometrics of plateau iris were significantly different from those of pupillary block eyes. However, our A-scan ultrasongraphy generally found no significant biometric differences between plateau iris and normal eyes. These findings suggest that while A-scan ultrasonography might be used as a practical tool for differentiating plateau iris and papillary block eyes, a more meticulous gonioscopy and other assessments may be necessary to distinguish plateau iris from normal eyes.

  6. VOYAGER 1&2 SATURN IRIS DERIVED NORTH/SOUTH PARAMETERS V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The data set contains Saturn atmospheric parameters derived from spectra obtained with the Voyager infrared interferometer spectrometer (IRIS). The data set is...

  7. Efficacy of standard versus enhanced features in a Web-based commercial weight-loss program for obese adults, part 2: randomized controlled trial.

    Science.gov (United States)

    Collins, Clare E; Morgan, Philip J; Hutchesson, Melinda J; Callister, Robin

    2013-07-22

    Commercial Web-based weight-loss programs are becoming more popular and increasingly refined through the addition of enhanced features, yet few randomized controlled trials (RCTs) have independently and rigorously evaluated the efficacy of these commercial programs or additional features. To determine whether overweight and obese adults randomized to an online weight-loss program with additional support features (enhanced) experienced a greater reduction in body mass index (BMI) and increased usage of program features after 12 and 24 weeks compared to those randomized to a standard online version (basic). An assessor-blinded RCT comparing 301 adults (male: n=125, 41.5%; mean age: 41.9 years, SD 10.2; mean BMI: 32.2 kg/m(2), SD 3.9) who were recruited and enrolled offline, and randomly allocated to basic or enhanced versions of a commercially available Web-based weight-loss program for 24 weeks. Retention at 24 weeks was greater in the enhanced group versus the basic group (basic 68.5%, enhanced 81.0%; P=.01). In the intention-to-treat analysis of covariance with imputation using last observation carried forward, after 24 weeks both intervention groups had reductions in key outcomes with no difference between groups: BMI (basic mean -1.1 kg/m(2), SD 1.5; enhanced mean -1.3 kg/m(2), SD 2.0; P=.29), weight (basic mean -3.3 kg, SD 4.7; enhanced mean -4.0 kg, SD 6.2; P=.27), waist circumference (basic mean -3.1 cm, SD 4.6; enhanced mean -4.0 cm, SD 6.2; P=.15), and waist-to-height ratio (basic mean -0.02, SD 0.03; enhanced mean -0.02, SD 0.04, P=.21). The enhanced group logged in more often at both 12 and 24 weeks, respectively (enhanced 12-week mean 34.1, SD 28.1 and 24-week mean 43.1, SD 34.0 vs basic 12-week mean 24.6, SD 25.5 and 24-week mean 31.8, SD 33.9; P=.002). The addition of personalized e-feedback in the enhanced program provided limited additional benefits compared to a standard commercial Web-based weight-loss program. However, it does support greater

  8. Linking International Development Actors to Geophysical Infrastructure: Exploring an IRIS Community Role in Bridging a Communications Gap

    Science.gov (United States)

    Lerner-Lam, A.; Aster, R.; Beck, S.; Ekstrom, G.; Fisher, K.; Meltzer, A.; Nyblade, A.; Sandvol, E.; Willemann, R.

    2008-12-01

    Over the past quarter century, national investments in high-fidelity digital seismograph networks have resulted in a global infrastructure for real-time in situ earthquake monitoring. Many network operators adhere to community-developed standards, with the result that there are few technical impediments to data sharing and real-time information exchange. Two unanswered questions, however, are whether the existing models of international collaboration will ensure the stability and sustainability of global earthquake monitoring, and whether the participating institutions can work with international development agencies and non- governmental organizations in meeting linked development and natural hazard risk reduction goals. Since the 2004 Indian Ocean tsunami, many of these actors are enlarging their commitments to natural hazard risk reduction and building national technical capacities, among broader programs in poverty alleviation and adaptation to environmental stress. Despite this renewed commitment, international development organizations, with notable exceptions, have been relatively passive in discussions of how the existing earthquake monitoring infrastructure could be leveraged to support risk-reduction programs and meet sustainable development goals. At the same time, the international seismological community - comprising universities and government seismological surveys - has built research and education initiatives such as EarthScope, AfricaArray, and similar programs in China, Europe and South America, that use innovative instrumentation technologies and deployment strategies to enable new science and applications, and promote education and training in critical sectors. Can these developments be combined? Recognizing this communication or knowledge gap, the IRIS International Working Group (IWG) explores the link between the activities of IRIS Members using IRIS facilities and the missions of international development agencies, such as US AID, the World

  9. Explosive events in active region observed by IRIS and SST/CRISP

    Science.gov (United States)

    Huang, Z.; Madjarska, M. S.; Scullion, E. M.; Xia, L.-D.; Doyle, J. G.; Ray, T.

    2017-01-01

    Transition-region explosive events (EEs) are characterized by non-Gaussian line profiles with enhanced wings at Doppler velocities of 50-150 km s-1. They are believed to be the signature of solar phenomena that are one of the main contributors to coronal heating. The aim of this study is to investigate the link of EEs to dynamic phenomena in the transition region and chromosphere in an active region. We analyse observations simultaneously taken by the Interface Region Imaging Spectrograph (IRIS) in the Si IV 1394 Å line and the slit-jaw (SJ) 1400 Å images, and the Swedish 1-m Solar Telescope in the Hα line. In total 24 events were found. They are associated with small-scale loop brightenings in SJ 1400 Å images. Only four events show a counterpart in the Hα-35 km s-1 and Hα+35 km s-1 images. Two of them represent brightenings in the conjunction region of several loops that are also related to a bright region (granular lane) in the Hα-35 km s-1 and Hα+35 km s-1 images. 16 are general loop brightenings that do not show any discernible response in the Hα images. Six EEs appear as propagating loop brightenings, from which two are associated with dark jet-like features clearly seen in the Hα-35 km s-1 images. We found that chromospheric events with jet-like appearance seen in the wings of the Hα line can trigger EEs in the transition region and in this case the IRIS Si IV 1394 Å line profiles are seeded with absorption components resulting from Fe II and Ni II. Our study indicates that EEs occurring in active regions have mostly upper-chromosphere/transition-region origin. We suggest that magnetic reconnection resulting from the braidings of small-scale transition region loops is one of the possible mechanisms of energy release that are responsible for the EEs reported in this paper.

  10. A 12-week commercial web-based weight-loss program for overweight and obese adults: randomized controlled trial comparing basic versus enhanced features.

    Science.gov (United States)

    Collins, Clare E; Morgan, Philip J; Jones, Penelope; Fletcher, Kate; Martin, Julia; Aguiar, Elroy J; Lucas, Ashlee; Neve, Melinda J; Callister, Robin

    2012-04-25

    The development and use of Web-based programs for weight loss is increasing rapidly, yet they have rarely been evaluated using randomized controlled trials (RCTs). Interestingly, most people who attempt weight loss use commercially available programs, yet it is very uncommon for commercial programs to be evaluated independently or rigorously. To compare the efficacy of a standard commercial Web-based weight-loss program (basic) versus an enhanced version of this Web program that provided additional personalized e-feedback and contact from the provider (enhanced) versus a wait-list control group (control) on weight outcomes in overweight and obese adults. This purely Web-based trial using a closed online user group was an assessor-blinded RCT with participants randomly allocated to the basic or enhanced 12-week Web-based program, based on social cognitive theory, or the control, with body mass index (BMI) as the primary outcome. We enrolled 309 adults (129/309, 41.8% male, BMI mean 32.3, SD 4 kg/m(2)) with 84.1% (260/309) retention at 12 weeks. Intention-to-treat analysis showed that both intervention groups reduced their BMI compared with the controls (basic: -0.72, SD 1.1 kg/m(2), enhanced: -1.0, SD 1.4, control: 0.15, SD 0.82; P Web-based weight-loss program can be efficacious across a range of weight-related outcomes and lifestyle behaviors and achieve clinically important weight loss. Although the provision of additional personalized feedback did not facilitate greater weight loss after 12 weeks, the impact of superior participant retention on longer-term outcomes requires further study. Further research is required to determine the optimal mix of program features that lead to the biggest treatment impact over time. Australian New Zealand Clinical Trials Registry (ANZCTR): 12610000197033.

  11. A Study in Speech Recognition Using a Kohonen Neural Network Dynamic Programming and Multi-Feature Fusion

    Science.gov (United States)

    1989-12-01

    FEATURE FUSION THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology Air University In Partial...years of schooling . Because of her sacrifice and understanding, I was able to fulfill many personal dreams. Wayne F. Recla AossionFo TIS GRA&f’- DTIC...where: 42 LINEAR / EXPONENTIAL Example Gain Graph Gaia Value 0.1 0.08 0.04 0.02 S󈧎 20 30 40 80 so 70 so 90 100 Training Iterations (x 1000) - Linea

  12. Behavioral and Neurological Responses to Musical Features in Adolescent Cochlear Implant Users Before and After an Intensive Musical Training Program

    DEFF Research Database (Denmark)

    Petersen, Bjørn

    This study aimed to investigate perception and processing of musical features in prelingually deaf adolescent CI-users and examine whether this is influenced by music training. Eleven adolescent CI-users received intensive music training for two weeks. Before and after training they completed...... responses for timbre, intensity and rhythm but not for pitch. No effect of training was found in the MMN responses. The findings indicate that despite congenital deafness and late implantation, young CI users are able to discriminate details in music. Furthermore, the behavioral advances suggest that......, in a wider perspective, music training may serve as a supplementary measure of rehabilitation....

  13. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma

    Directory of Open Access Journals (Sweden)

    Mizoguchi T

    2015-06-01

    Full Text Available Takanori Mizoguchi,1 Mineo Ozaki,2,3 Harumi Wakiyama,1,4 Nobuchika Ogino1,51Mizoguchi Eye Clinic, Nagasaki, Japan; 2Ozaki Eye Clinic Miyazaki, Japan; 3Department of Ophthalmology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan; 4The Japanese Red Cross Nagasaki Genbaku Hospital, Nagasaki, Japan; 5Nishigaki Eye Clinic, Nagoya, JapanPurpose: To determine the prevalence of plateau iris in Japanese patients with primary angle closure (PAC and primary angle closure glaucoma (PACG and analyze the biometric parameters in patients with plateau iris using ultrasound biomicroscopy (UBM.Methods: In this cross-sectional observational study, subjects aged >50 years with PAC and PACG who had previously undergone a patent laser peripheral iridotomy underwent UBM in one eye. UBM images were qualitatively analyzed using standardized criteria. Plateau iris in a quadrant was defined by anteriorly directed ciliary body, absent ciliary sulcus, steep iris root from its point of insertion followed by a downward angulation, flat iris plane, and irido-angle contact. At least two quadrants had to fulfill these UBM criteria for an eye to be classified as having plateau iris. A-scan biometry was used to measure anterior segment parameters.Results: Ninety-one subjects with PAC (58 subjects or PACG (33 subjects and 68 normal controls were recruited. The mean (standard deviation ages of PAC and PACG patients and normal controls were 73.5 (6.2 and 72.6 (7.3, respectively. Based on UBM criteria, plateau iris was found in 16 eyes (17.6% of 91 eyes. In these 16 eyes, quadrant-wise analysis showed ten eyes (62.5% had plateau iris in two quadrants; four eyes (25% had plateau iris in three quadrants; and two eyes (12.5% had plateau iris in four quadrants. Anterior chamber depth, lens thickness, axial length, lens position, and relative lens position were not statistically significant between the group having plateau iris and that not having plateau iris

  14. Hyaluronic acid production and hyaluronidase activity in the newt iris during lens regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Kulyk, W.M.; Zalik, S.E.; Dimitrov, E.

    1987-09-01

    The process of lens regeneration in newts involves the dedifferentiation of pigmented iris epithelial cells and their subsequent conversion into lens fibers. In vivo this cell-type conversion is restricted to the dorsal region of the iris. We have examined the patterns of hyaluronate accumulation and endogenous hyaluronidase activity in the newt iris during the course of lens regeneration in vivo. Accumulation of newly synthesized hyaluronate was estimated from the uptake of (/sup 3/H)glucosamine into cetylpyridinium chloride-precipitable material that was sensitive to Streptomyces hyaluronidase. Endogenous hyaluronidase activity was determined from the quantity of reducing N-acetylhexosamine released upon incubation of iris tissue extract with exogenous hyaluronate substrate. We found that incorporation of label into hyaluronate was consistently higher in the regeneration-activated irises of lentectomized eyes than in control irises from sham-operated eyes. Hyaluronate labeling was higher in the dorsal (lens-forming) region of the iris than in ventral (non-lens-forming) iris tissue during the regeneration process. Label accumulation into hyaluronate was maximum between 10 and 15 days after lentectomy, the period of most pronounced dedifferentiation in the dorsal iris epithelium. Both normal and regenerating irises demonstrated a high level of endogenous hyaluronidase activity with a pH optimum of 3.5-4.0. Hyaluronidase activity was 1.7 to 2 times higher in dorsal iris tissue than in ventral irises both prior to lentectomy and throughout the regeneration process. We suggest that enhanced hyaluronate accumulation may facilitate the dedifferentiation of iris epithelial cells in the dorsal iris and prevent precocious withdrawal from the cell cycle. The high level of hyaluronidase activity in the dorsal iris may promote the turnover and remodeling of extracellular matrix components required for cell-type conversion.

  15. IRIS perspectives on the future of the SEED format

    Science.gov (United States)

    Trabant, Chad; Ahern, Tim; Benson, Rick

    2016-04-01

    The Standard for the Exchange Earthquake Data (SEED) was formally adopted by the International Federation of Digital Seismograph Networks (FDSN) in 1987. Since that time, SEED has served as the dominant standard for passive source seismological data, and has been adopted for use by a variety of other uniformly sampled time series data. The IRIS Data Management Center (DMC) was an early adopter and architect in addition to maintaining key software components of the SEED ecosystem. The SEED format, containing both time series data and related metadata, has been the primary archive and distribution format for the DMC for decades. After nearly 30 years, the SEED format is undergoing an evolution motivated by multiple factors, including the need for modern encoding, modern transmission and metadata expansion due to limitations. Within the last few years a new XML schema for expressing SEED metadata, called StationXML, was approved by the FDSN and is being adopted by multiple data centers and seismic software systems. The complete transition of users and centers to this new metadata format will take years. The DMC's strategy to promote this transition includes offering metadata in StationXML format, distributing a stand-alone program to convert between StationXML and SEED header format and accepting StationXML as the primary means of describing time series data. We will present the details of this strategy, known challenges, and current status. One key change needed in SEED is an expansion of the two-character network code to allow for identification of the increasing number geophysical networks in the world today. This change is relatively easy in the StationXML metadata, but requires a corresponding change in the fixed-length field format of SEED time series data known as miniSEED. Such an incompatible change in miniSEED affords the opportunity to make a number of other changes to miniSEED. The DMC has identified two classes of changes to miniSEED to be considered by

  16. Delay of iris flower senescence by cytokinins and jasmonates.

    Science.gov (United States)

    van Doorn, Wouter G; Çelikel, Fisun G; Pak, Caroline; Harkema, Harmannus

    2013-05-01

    It is not known whether tepal senescence in Iris flowers is regulated by hormones. We applied hormones and hormone inhibitors to cut flowers and isolated tepals of Iris × hollandica cv. Blue Magic. Treatments with ethylene or ethylene antagonists indicated lack of ethylene involvement. Auxins or auxin inhibitors also did not change the time to senescence. Abscisic acid (ABA) hastened senescence, but an inhibitor of ABA synthesis (norflurazon) had no effect. Gibberellic acid (GA3 ) slightly delayed senescence in some experiments, but in other experiments it was without effect, and gibberellin inhibitors [ancymidol or 4-hydroxy-5-isopropyl-2-methylphenyltrimethyl ammonium chloride-1-piperidine carboxylate (AMO-1618)] were ineffective as well. Salicylic acid (SA) also had no effect. Ethylene, auxins, GA3 and SA affected flower opening, therefore did reach the flower cells. Jasmonates delayed senescence by about 2.0 days. Similarly, cytokinins delayed senescence by about 1.5-2.0 days. Antagonists of the phosphatidylinositol signal transduction pathway (lithium), calcium channels (niguldipine and verapamil), calmodulin action [fluphenazine, trifluoroperazine, phenoxybenzamide and N-(6-aminohexyl)-5-chloro-1-naphtalenesulfonamide hydrochloride (W-7)] or protein kinase activity [1-(5-isoquinolinesulfonyl)-2-methylpiperazine hydrochloride (H-7), N-[2-(methylamino)ethyl]-5-isoquinolinesulfonamide hydrochloride (H-8) and N-(2-aminoethyl)-5-isoquinolinesulfonamide dihydrochloride (H-9)] had no effect on senescence, indicating no role of a few common signal transduction pathways relating to hormone effects on senescence. The results indicate that tepal senescence in Iris cv. Blue Magic is not regulated by endogenous ethylene, auxin, gibberellins or SA. A role of ABA can at present not be excluded. The data suggest the hypothesis that cytokinins and jasmonates are among the natural regulators. Copyright © Physiologia Plantarum 2012.

  17. A Reading Skills Development Program for Adult Non-Readers. Featuring: Supplementary Graphics and Sound (Voice Tutorials). Volumes 1 and 2. The TRS-80 Computer Assisted Instruction Series for Adult Basic Education Students.

    Science.gov (United States)

    San Antonio State Hospital, TX. Office of Education Services.

    This instructional manual consists of materials for use in implementing a computer-assisted instructional program in reading skills development for adult nonreaders. Discussed first are the project during which this instructional program and manual were developed and the goals of the computer-assisted beginning reading program, a major feature of…

  18. A rare case report: Iris intraocular foreign body

    Directory of Open Access Journals (Sweden)

    Shivanand C Bubanale

    2015-01-01

    Full Text Available We are reporting a case of the safe removal of the iron intraocular foreign body embedded on the iris with the use of forceps. Preoperative best-corrected visual acuity was 20/20. Cornea showed self-sealed entry site with no other ocular injury. With such good vision, there is a definite challenge to maintain vision and avoid subsequent serious complications. The foreign body was successfully removed via limbal route with use of forceps. Postoperative best corrected visual acuity was 20/20 with very minimal surgical damage.

  19. Virtual Ionosonde Construction by using ITS and IRI-2012 models

    Science.gov (United States)

    Kabasakal, Mehmet; Toker, Cenk

    2016-07-01

    Ionosonde is a kind of radar which is used to examine several properties of the ionosphere, including the electron density and drift velocity. Ionosonde is an expensive device and its installation requires special expertise and a proper area clear of sources of radio interference. In order to overcome the difficulties of installing an ionosonde hardware, the target of this study is to construct a virtual ionosonde based on communication channel models where the model parameters are determined by ray tracing obtained by the PHaRLAP software and the International Reference Ionosphere (IRI-2012) model. Although narrowband high frequency (HF) communication models have been widely used to represent the behaviour of the radio channel, they are applicable to a limited set of actual propagation conditions and wideband models are needed to better understand the HF channel. In 1997, the Institute for Telecommunication Science (ITS) developed a wideband HF ionospheric model, the so-called ITS model, however, it has some restrictions in real life applications. The ITS model parameters are grouped into two parts; the deterministic and the stochastic parameters. The deterministic parameters are the delay time (tau _{c}) of each reflection path based on the penetration frequency (f _{p}), the height (h _{0}) of the maximum electron density and the half thickness (sigma) of the reflective layer. The stochastic parameters, delay spread (sigma _{tau}), delay rise time (sigma _{c}), Doppler spread (sigma _{D}), Doppler shift (f _{s}), are to calculate the impulse response of the channel. These parameters are generally difficult to obtain and are based on the measured data which may not be available in all cases. In order to obtain these parameters, we propose to integrate the PHaRLAP ray tracing toolbox and the IRI-2012 model. When Total Electron Content (TEC) estimates obtained from GNSS measurements are input to IRI-2012, the model generates electron density profiles close to the

  20. Reliability of Iris Scanning as a Means of Identity Verification and Future Impact on Transportation Worker Identification Credential

    National Research Council Canada - National Science Library

    McLaren, Simon

    2008-01-01

    .... Congress mandated the TWIC have a biometric authenticator; DHS chose fingerprints. This thesis argues iris scanning is a better choice because of the nature of the maritime environment and because iris scanning is a more accurate biometric...

  1. Modeling IrisCode and its variants as convex polyhedral cones and its security implications.

    Science.gov (United States)

    Kong, Adams Wai-Kin

    2013-03-01

    IrisCode, developed by Daugman, in 1993, is the most influential iris recognition algorithm. A thorough understanding of IrisCode is essential, because over 100 million persons have been enrolled by this algorithm and many biometric personal identification and template protection methods have been developed based on IrisCode. This paper indicates that a template produced by IrisCode or its variants is a convex polyhedral cone in a hyperspace. Its central ray, being a rough representation of the original biometric signal, can be computed by a simple algorithm, which can often be implemented in one Matlab command line. The central ray is an expected ray and also an optimal ray of an objective function on a group of distributions. This algorithm is derived from geometric properties of a convex polyhedral cone but does not rely on any prior knowledge (e.g., iris images). The experimental results show that biometric templates, including iris and palmprint templates, produced by different recognition methods can be matched through the central rays in their convex polyhedral cones and that templates protected by a method extended from IrisCode can be broken into. These experimental results indicate that, without a thorough security analysis, convex polyhedral cone templates cannot be assumed secure. Additionally, the simplicity of the algorithm implies that even junior hackers without knowledge of advanced image processing and biometric databases can still break into protected templates and reveal relationships among templates produced by different recognition methods.

  2. 76 FR 13402 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2011-03-11

    ... AGENCY Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches for... literature searches for IRIS assessments; request for information. SUMMARY: The U.S. Environmental Protection Agency (EPA) is announcing the availability of literature searches for cobalt (CASRN 7440-48-4) and...

  3. 77 FR 20817 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2012-04-06

    ... AGENCY Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches for... literature searches for IRIS assessments; request for information. SUMMARY: The U.S. Environmental Protection Agency (EPA) is announcing the availability of literature searches for acetaldehyde (75-07-0) and 1,2,3...

  4. Systematic Review Protocol for the IRIS Chloroform Assessment (Inhalation) (Preliminary Assessment Materials)

    Science.gov (United States)

    In January 2018, EPA released the Systematic Review Protocol for the IRIS Chloroform Assessment (Inhalation) for public review and comment. As part of developing a draft IRIS assessment, EPA presents a methods document, referred to as the protocol, for conducting a chem...

  5. Protective effect of Iris germanica L. in β-amyloid-induced animal ...

    African Journals Online (AJOL)

    Protective effect of Iris germanica L. in β-amyloid-induced animal model of alzheimer's disease. ... The day after surgery, animals in treatment groups received different doses of the aqueous extract of Iris by gavage for 30 days. Morris water maze test (MWM) was performed to assess the effects of I. germanica on learning ...

  6. Iris: Constructing and Analyzing Spectral Energy Distributions with the Virtual Observatory

    Science.gov (United States)

    Laurino, O.; Budynkiewicz, J.; Busko, I.; Cresitello-Dittmar, M.; D'Abrusco, R.; Doe, S.; Evans, J.; Pevunova, O.

    2014-05-01

    We present Iris 2.0, the latest release of the Virtual Astronomical Observatory application for building and analyzing Spectral Energy Distributions (SEDs). With Iris, users may read in and display SEDs inspect and edit any selection of SED data, fit models to SEDs in arbitrary spectral ranges, and calculate confidence limits on best-fit parameters. SED data may be loaded into the application from VOTable and FITS files compliant with the International Virtual Observatoy Alliance interoperable data models, or retrieved directly from NED or the Italian Space Agency Science Data Center; data in non-standard formats may also be converted within the application. Users may seamlessy exchange data between Iris and other Virtual Observatoy tools using the Simple Application Messaging Protocol. Iris 2.0 also provides a tool for redshifting, interpolating, and measuring integratd fluxes, and allows simple aperture corrections for individual points and SED segments. Custom Python functions, template models and template libraries may be imported into Iris for fitting SEDs. Iris may be extended through Java plugins; users can install third-party packages, or develop their own plugin using Iris' Software Development Kit. Iris 2.0 is available for Linux and Mac OS X systems.

  7. Special test results evaluation features as development of “Innovations management” program - NEFU testing area as case-study

    Science.gov (United States)

    Ermakov, A. V.; Bessmertnyy, A. M.

    2017-10-01

    This article gives an overview on the problems of precision in the results evaluation of the tests carried out in the Northern testing areas. One of the significant features of the facilities under study is that they are limited in quantity. In cases when a facility is taken down, that quantity is normally equal to one. The complexity of modern technological equipment and other circumstances require researchers to take into account and evaluate the potential risks. In order to make the sought-for estimations more precise, ways of improving the test result evaluations algorithms are suggested. In particular, one of the productive methods is the Data Mining technology, which presupposes implementing an intellectual analysis of the data with the aim of extracting useful information from the available database which was attained during the tests and other types of activities. Applying the Data Mining technology is becoming more productive when the scenario analysis is carried out, i.e., the analysis of possible alternative solutions. Another perspective trend is an implementation of an interdisciplinary approach. As a result, researchers are able to carry out a complex evaluation of the test results, which will noticeably increase the value of the given results.

  8. Free-Floating Iris Cyst in a Patient with Recurrent Iritis

    Directory of Open Access Journals (Sweden)

    Joanne M.Y. Teong

    2015-06-01

    Full Text Available Purpose: We describe an unusual clinical finding of a free-floating iris cyst in a patient with recurrent iritis. Method: The clinical finding of a free-floating iris cyst was recorded using slit-lamp photography. Results: A 39-year-old male with a 5-year history of recurrent right iritis was found to have a small mobile iris cyst within his right anterior chamber, first identified 3 years ago. The patient did not experience any discomfort or visual symptoms resulting from the cyst. Conclusion: Surgical removal is not indicated for asymptomatic non-progressive free-floating iris cysts. The significance of a free-floating iris cyst in the setting of recurrent iritis remains unknown.

  9. [Use of computer technologies for studying the morphological characteristics of the iris color in anthropology].

    Science.gov (United States)

    Dorofeeva, A A; Khrustalev, A V; Krylov, Iu V; Bocharov, D A; Negasheva, M A

    2010-01-01

    Digital images of the iris were received for study peculiarities of the iris color during the anthropological examination of 578 students aged 16-24 years. Simultaneously with the registration of the digital images, the visual assessment of the eye color was carried out using the traditional scale of Bunak, based on 12 ocular prostheses. Original software for automatic determination of the iris color based on 12 classes scale of Bunak was designed, and computer version of that scale was developed. The software proposed allows to conduct the determination of the iris color with high validity based on numerical evaluation; its application may reduce the bias due to subjective assessment and methodological divergences of the different researchers. The software designed for automatic determination of the iris color may help develop both theoretical and applied anthropology, it may be used in forensic and emergency medicine, sports medicine, medico-genetic counseling and professional selection.

  10. Programmatic access to data and information at the IRIS DMC via web services

    Science.gov (United States)

    Weertman, B. R.; Trabant, C.; Karstens, R.; Suleiman, Y. Y.; Ahern, T. K.; Casey, R.; Benson, R. B.

    2011-12-01

    The IRIS Data Management Center (DMC) has developed a suite of web services that provide access to the DMC's time series holdings, their related metadata and earthquake catalogs. In addition, services are available to perform simple, on-demand time series processing at the DMC prior to being shipped to the user. The primary goal is to provide programmatic access to data and processing services in a manner usable by and useful to the research community. The web services are relatively simple to understand and use and will form the foundation on which future DMC access tools will be built. Based on standard Web technologies they can be accessed programmatically with a wide range of programming languages (e.g. Perl, Python, Java), command line utilities such as wget and curl or with any web browser. We anticipate these services being used for everything from simple command line access, used in shell scripts and higher programming languages to being integrated within complex data processing software. In addition to improving access to our data by the seismological community the web services will also make our data more accessible to other disciplines. The web services available from the DMC include ws-bulkdataselect for the retrieval of large volumes of miniSEED data, ws-timeseries for the retrieval of individual segments of time series data in a variety of formats (miniSEED, SAC, ASCII, audio WAVE, and PNG plots) with optional signal processing, ws-station for station metadata in StationXML format, ws-resp for the retrieval of instrument response in RESP format, ws-sacpz for the retrieval of sensor response in the SAC poles and zeros convention and ws-event for the retrieval of earthquake catalogs. To make the services even easier to use, the DMC is developing a library that allows Java programmers to seamlessly retrieve and integrate DMC information into their own programs. The library will handle all aspects of dealing with the services and will parse the returned

  11. Survey of HTR related research at IRI, Delft, Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; Wallerbos, E.J.M.; Van der Hagen, T.H.J.J.; Van Dam, H. [Interfaculty Reactor Institute IRI, Delft University of Technology, Delft (Netherlands); Tuerkcan, E. [ECN Nuclear Research, Petten (Netherlands)

    1998-09-01

    High temperature helium-cooled reactors have a large potential for inherent safety. Therefore, several projects on HTR research are being carried out or were carried out at the Interfaculty Reactor Institute (IRI) of the Delft University of Technology in Delft, Netherlands. As part of a larger research programme measurements of core reactivity, reactivity worth of safety rods and of small samples being oscillated in the reactor core were carried out at the PROTEUS facility of the Paul Scherrer Institute at Villigen, Switzerland. Together with other partners in the Netherlands a small inherently safe co-generation plant with a pebble-bed HTR core was designed and analysed. It was verified that such a reactor can operate continuously for 10 years by adding continuously fuel pebbles until the maximum available core height is reached. As a new, innovative, inherently safe reactor type the design of a fluidized-bed reactor with coated fuel particles on a helium gas stream is discussed and results are shown for the analysis of inherent criticality safety under varying coolant flow rates. IRI is also taking part in the new IAEA Co-ordinated Research Programme, which involves participation in the start-up experiments of the Japanese HTTR and carrying out calculations for the core physics benchmark test. 11 refs.

  12. THE ITALIAN IRIS SOCIETY: ITS GARDEN AND WORK

    Directory of Open Access Journals (Sweden)

    M. CAMERON LONGO

    2000-01-01

    Full Text Available The Italian Iris Society was born in Florence (Italy in 1959 to manage the International contest which started in 1957. This year (1998 we are going to celebrate the 42nd edition. The aim is to judge new hybrids from all over the world. The breeders send their rhizomes to Florence three years prior to judgment, made during five days work by five international experts, which are changed every year. The venue of the contest is the Iris Gardens located at the foot of Michelangelo Square. The judgement is made on the general characteristics of the plant and flowers of each variety, in order to award the established prizes, of which the first is a reproduction of the Golden Florin. The contest is normally scheduled in the first half of May, this year 11th-16th, and the announcement of the winner is made in the solemnity of the Town Hall, the famous and well-known “Palazzo Vecchio”.

  13. THE ITALIAN IRIS SOCIETY: ITS GARDEN AND WORK

    Directory of Open Access Journals (Sweden)

    M. CAMERON LONGO

    2000-04-01

    Full Text Available The Italian Iris Society was born in Florence (Italy in 1959 to manage the International contest which started in 1957. This year (1998 we are going to celebrate the 42nd edition. The aim is to judge new hybrids from all over the world. The breeders send their rhizomes to Florence three years prior to judgment, made during five days work by five international experts, which are changed every year. The venue of the contest is the Iris Gardens located at the foot of Michelangelo Square. The judgement is made on the general characteristics of the plant and flowers of each variety, in order to award the established prizes, of which the first is a reproduction of the Golden Florin. The contest is normally scheduled in the first half of May, this year 11th-16th, and the announcement of the winner is made in the solemnity of the Town Hall, the famous and well-known “Palazzo Vecchio”.

  14. Fractional Scaling Analysis for IRIS pressurizer reduced scale experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bezerra da Silva, Mario Augusto, E-mail: mabs500@gmail.co [Departamento de Energia Nuclear - Centro de Tecnologia e Geociencias, Universidade Federal de Pernambuco, Av. Prof. Luiz Freire, 1000, 50740-540 Recife, PE (Brazil); Brayner de Oliveira Lira, Carlos Alberto, E-mail: cabol@ufpe.b [Departamento de Energia Nuclear - Centro de Tecnologia e Geociencias, Universidade Federal de Pernambuco, Av. Prof. Luiz Freire, 1000, 50740-540 Recife, PE (Brazil); Oliveira Barroso, Antonio Carlos de, E-mail: barroso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares - Comissao Nacional de Energia Nuclear, Av. Prof. Lineu Prestes, 2242, 05508-900 Cidade Universitaria, Sao Paulo (Brazil)

    2010-10-15

    About twenty organizations joined in a consortium led by Westinghouse to develop an integral, modular and medium size pressurized water reactor (PWR), known as international reactor innovative and secure (IRIS), which is characterized by having most of its components inside the pressure vessel, eliminating or minimizing the probability of severe accidents. The pressurizer is responsible for pressure control in PWRs. A small continuous flow is maintained by the spray system in conventional pressurizers. This mini-flow allows a mixing between the reactor coolant and the pressurizer water, warranting acceptable limits for occasional differences in boron concentrations. There are neither surge lines nor spray in IRIS pressurizer, but surge and recirculation orifices that promote a circulation flow between primary system and pressurizer, avoiding power transients whether outsurges occur. The construction of models is a routine practice in engineering, being supported by similarity rules. A new method of scaling systems, Fractional Scaling Analysis, has been successfully used to analyze pressure variations, considering the most relevant agents of change. The aim of this analysis is to obtain the initial boron concentration ratio and the volumetric flows that ensure similar behavior for boron dispersion in a prototype and its model.

  15. Bottlenose dolphin iris asymmetries enhance aerial and underwater vision

    Science.gov (United States)

    Rivamonte, Andre

    2009-02-01

    When the iris of the Bottlenose dolphin (Tursiops truncatus) contracts it constrains the path of light that can focus onto the two areas of the retina having a finer retinal mosaic. Under high ambient light conditions the operculum of the iris shields the lens and forms in the process two asymmetrically shaped, sized and positioned slit pupils. Tracing rays of light in the reverse direction through the pupils from the retinal regions associated with higher resolution confirm behaviorally observed preferred aerial and underwater viewing directions. In the forward and downward viewing direction, the larger temporal pupil admits light that is focused by the weakly refractive margin of a bifocal lens onto the temporal area centralis compensating for the addition of the optically strong front surface of the cornea in air. A schematic dolphin eye model incorporating a bifocal lens offers an explanation for a dolphin's comparable visual acuities in air and water for both high and low ambient light conditions. Comparison of methods for curve fitting psychometric ogive functions to behavioral visual acuity and spectral sensitivity data are discussed.

  16. Unilatelaral iris plateau syndrome after the use of ecstasy

    Directory of Open Access Journals (Sweden)

    Jovanović Predrag

    2009-01-01

    Full Text Available Bacground. Courmon street name for 3,4-Methylenedioxymethamphetamine (MDMA is ecstasy. This widely abused 'recreational' drug causes both an increased release of monoamine neurotransmitters, including serotonine and dopamine, and an increased reuptake inhibition of serotonin. As a consequence, mydriasis and increased intraocular pressure (IOP in predisposed patients occur. We present herein a rare case of acute increased IOP after use of ecstasy. Case report. A female patient, aged 38 years, visited doctor complaing of a decreased vision acuity and severe pain in the left eye and in the left part of the head. The initial treatment was urgent antiglaucomatous therapy followed by withdrawal of subjective problems of the patient and improvement of objective finding. History taking procedure reveled that just before the onset of the pain the patient had used ecstasy and had had similar 'experience' 6 years ago after cocaine snorting. She had not been to a doctor although she had experienced sporadic migrenous pain. Previous medical records excavation of revealed optic disk (cup-to-dise C/D=06, Bjerum arcuate scotoma and iris plateau with narrow chamber angle (Scheie II- III so the diagnosis was a rare unilateral iris plateau syndrome of the left eye. Although the patient was given some pieces of information about the dangerous and possible deadly consequences of psychoactive substance abuse, she has not continue the treatment. Conclusion. Ecstasy abuse might cause a complete loss of vision, thus medicametous and surgical treatment are obligatory.

  17. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography.

    Directory of Open Access Journals (Sweden)

    Yu-Yen Chen

    Full Text Available To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy.In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes.The normal controls, plateau iris group and pupillary block group were significantly different in age, but not in gender. The anterior chamber depth tended to decrease and the lens thickness tended to increase from normal to plateau iris to pupillary block eyes. Compared to those of plateau iris group, the pupillary block group had significantly shallower anterior chamber depth (2.90mm vs. 2.33mm; p<0.001, thicker lens (4.77mm vs. 5.11mm; p<0.001, shorter axial length (23.16mm vs. 22.63mm; p<0.001, smaller relative lens position (2.28 vs. 2.16; p<0.001 and larger lens/axial length factor (2.06 vs. 2.26; p<0.001. However, when comparing plateau iris and normal eyes, only axial length and lens/axial length factor were significantly different (23.16 vs. 23.54; p<0.05 and 2.06 vs. 1.96; p<0.05.Measured by A-scan ultrasonography, the ocular biometrics of plateau iris were significantly different from those of pupillary block eyes. However, our A-scan ultrasongraphy generally found no significant biometric differences between plateau iris and normal eyes. These findings suggest that while A-scan ultrasonography might be used as a practical tool for differentiating plateau iris and papillary block eyes, a more meticulous gonioscopy and other assessments may be necessary to distinguish plateau iris from normal eyes.

  18. Colorimetric measurements of iris colour and their significance in East Asian patients with skin cancer.

    Science.gov (United States)

    Kim, J W; Seo, S H; Kye, Y C; Ahn, H H

    2010-10-01

    A light-coloured iris is considered a risk factor for skin cancer in general. However, iris colour cannot be considered a plausible risk factor for skin cancer in East Asian populations because of the relative homogeneity of iris colours. Furthermore, subjective classifications of iris colour cannot distinguish between different East Asian individuals as to their likelihood of developing cancer. To measure human iris colours quantitatively and to assess the significances of iris colours with respect to skin cancer in Korean patients. Reference Commission Internationale d'Eclairage (CIE) L*a*b* coordinates on a ColorCheck chart were recorded using a reflectance spectrophotometer and compared with computed CIE L*a*b* coordinates from digital images to determine equations to calibrate CIE L*a*b* values. We then took iris images and measured iris colours and the colours of sun-exposed and sun-protected skin in 42 Korean patients with various cutaneous malignancies and nonmalignant dermatological diseases. Results were statistically analysed with regard to iris and skin colours in CIE L*a*b* coordinates. Patients with skin cancer had significantly lighter irises or higher L* values than dermatological patients without a malignancy (P = 0.02). Colour differences (ΔE*ab) between sun-exposed skin and sun-protected skin were greater in men (P < 0.01) and in patients with skin cancer (P < 0.01), and the lightness (L*) values of sun-exposed skins decreased with age (r = -0.32, P < 0.05). Iris colour appears to be a possible skin cancer risk factor in East Asian populations. The larger colour differences seen between sun-protected and sun-exposed skin in men and in patients with skin cancer may have been due to chronic or excessive sun exposure. © 2009 The Author(s). Journal compilation © 2009 British Association of Dermatologists.

  19. Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population.

    Science.gov (United States)

    Invernizzi, Alessandro; Giardini, Piero; Cigada, Mario; Viola, Francesco; Staurenghi, Giovanni

    2015-07-01

    We analyzed by swept-source anterior segment optical coherence tomography (SS-ASOCT) the three-dimensional iris morphology in a Caucasian population, and correlated the findings with iris color, iris sectors, subject age, and sex. One eye each from consecutive healthy emmetropic (refractive spherical equivalent ± 3 diopters) volunteers were selected for the study. The enrolled eye underwent standardized anterior segment photography to assess iris color. Iris images were assessed by SS-ASOCT for volume, thickness, width, and pupil size. Sectoral variations of morphometric data among the superior, nasal, inferior, and temporal sectors were recorded. A total of 135 eyes from 57 males and 78 females, age 49 ± 17 years, fulfilled the inclusion criteria. All iris morphometric parameters varied significantly among the different sectors (all P pupil diameter was influenced by iris color. Age did not affect iris volume or thickness; iris width increased and pupil diameter decreased with age (rs = 0.52, rs = -0.58, respectively). There was no effect of sex on iris volume, thickness, or pupil diameter; iris width was significantly greater in males (P = 0.007). Morphology of the iris varied by iris sector, and iris color was associated with differences in iris volume and thickness. Morphological parameter variations associated with iris color, sector, age, and sex can be used to identify pathological changes in suspect eyes. To be effective in clinical settings, construction of iris morphological databases for different ethnic and racial populations is essential.

  20. A 12-Week Commercial Web-Based Weight-Loss Program for Overweight and Obese Adults: Randomized Controlled Trial Comparing Basic Versus Enhanced Features

    Science.gov (United States)

    Morgan, Philip J; Jones, Penelope; Fletcher, Kate; Martin, Julia; Aguiar, Elroy J; Lucas, Ashlee; Neve, Melinda J; Callister, Robin

    2012-01-01

    Background The development and use of Web-based programs for weight loss is increasing rapidly, yet they have rarely been evaluated using randomized controlled trials (RCTs). Interestingly, most people who attempt weight loss use commercially available programs, yet it is very uncommon for commercial programs to be evaluated independently or rigorously. Objective To compare the efficacy of a standard commercial Web-based weight-loss program (basic) versus an enhanced version of this Web program that provided additional personalized e-feedback and contact from the provider (enhanced) versus a wait-list control group (control) on weight outcomes in overweight and obese adults. Methods This purely Web-based trial using a closed online user group was an assessor-blinded RCT with participants randomly allocated to the basic or enhanced 12-week Web-based program, based on social cognitive theory, or the control, with body mass index (BMI) as the primary outcome. Results We enrolled 309 adults (129/309, 41.8% male, BMI mean 32.3, SD 4 kg/m2) with 84.1% (260/309) retention at 12 weeks. Intention-to-treat analysis showed that both intervention groups reduced their BMI compared with the controls (basic: –0.72, SD 1.1 kg/m2, enhanced: –1.0, SD 1.4, control: 0.15, SD 0.82; P 3.0, SD 4.1, control: 0.4, SD 2.3; P 2.0, SD 3.5 cm, enhanced: –3.2, SD 4.7, control: 0.5, SD 3.0; P Web-based weight-loss program can be efficacious across a range of weight-related outcomes and lifestyle behaviors and achieve clinically important weight loss. Although the provision of additional personalized feedback did not facilitate greater weight loss after 12 weeks, the impact of superior participant retention on longer-term outcomes requires further study. Further research is required to determine the optimal mix of program features that lead to the biggest treatment impact over time. Trial Registration Australian New Zealand Clinical Trials Registry (ANZCTR): 12610000197033; http

  1. Positive Selection of Iris, a Retroviral Envelope-Derived Host Gene in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    2005-10-01

    Full Text Available Eukaryotic genomes can usurp enzymatic functions encoded by mobile elements for their own use. A particularly interesting kind of acquisition involves the domestication of retroviral envelope genes, which confer infectious membrane-fusion ability to retroviruses. So far, these examples have been limited to vertebrate genomes, including primates where the domesticated envelope is under purifying selection to assist placental function. Here, we show that in Drosophila genomes, a previously unannotated gene (CG4715, renamed Iris was domesticated from a novel, active Kanga lineage of insect retroviruses at least 25 million years ago, and has since been maintained as a host gene that is expressed in all adult tissues. Iris and the envelope genes from Kanga retroviruses are homologous to those found in insect baculoviruses and gypsy and roo insect retroviruses. Two separate envelope domestications from the Kanga and roo retroviruses have taken place, in fruit fly and mosquito genomes, respectively. Whereas retroviral envelopes are proteolytically cleaved into the ligand-interaction and membrane-fusion domains, Iris appears to lack this cleavage site. In the takahashii/suzukii species groups of Drosophila, we find that Iris has tandemly duplicated to give rise to two genes (Iris-A and Iris-B. Iris-B has significantly diverged from the Iris-A lineage, primarily because of the "invention" of an intron de novo in what was previously exonic sequence. Unlike domesticated retroviral envelope genes in mammals, we find that Iris has been subject to strong positive selection between Drosophila species. The rapid, adaptive evolution of Iris is sufficient to unambiguously distinguish the phylogenies of three closely related sibling species of Drosophila (D. simulans, D. sechellia, and D. mauritiana, a discriminative power previously described only for a putative "speciation gene." Iris represents the first instance of a retroviral envelope-derived host gene

  2. Positive selection of Iris, a retroviral envelope-derived host gene in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Harmit S Malik

    2005-10-01

    Full Text Available Eukaryotic genomes can usurp enzymatic functions encoded by mobile elements for their own use. A particularly interesting kind of acquisition involves the domestication of retroviral envelope genes, which confer infectious membrane-fusion ability to retroviruses. So far, these examples have been limited to vertebrate genomes, including primates where the domesticated envelope is under purifying selection to assist placental function. Here, we show that in Drosophila genomes, a previously unannotated gene (CG4715, renamed Iris was domesticated from a novel, active Kanga lineage of insect retroviruses at least 25 million years ago, and has since been maintained as a host gene that is expressed in all adult tissues. Iris and the envelope genes from Kanga retroviruses are homologous to those found in insect baculoviruses and gypsy and roo insect retroviruses. Two separate envelope domestications from the Kanga and roo retroviruses have taken place, in fruit fly and mosquito genomes, respectively. Whereas retroviral envelopes are proteolytically cleaved into the ligand-interaction and membrane-fusion domains, Iris appears to lack this cleavage site. In the takahashii/suzukii species groups of Drosophila, we find that Iris has tandemly duplicated to give rise to two genes (Iris-A and Iris-B. Iris-B has significantly diverged from the Iris-A lineage, primarily because of the "invention" of an intron de novo in what was previously exonic sequence. Unlike domesticated retroviral envelope genes in mammals, we find that Iris has been subject to strong positive selection between Drosophila species. The rapid, adaptive evolution of Iris is sufficient to unambiguously distinguish the phylogenies of three closely related sibling species of Drosophila (D. simulans, D. sechellia, and D. mauritiana, a discriminative power previously described only for a putative "speciation gene." Iris represents the first instance of a retroviral envelope-derived host gene

  3. Fluid and structure coupling analysis of the interaction between aqueous humor and iris.

    Science.gov (United States)

    Wang, Wenjia; Qian, Xiuqing; Song, Hongfang; Zhang, Mindi; Liu, Zhicheng

    2016-12-28

    Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results

  4. Strategic partnering to improve community health worker programming and performance: features of a community-health system integrated approach.

    Science.gov (United States)

    Naimoli, Joseph F; Perry, Henry B; Townsend, John W; Frymus, Diana E; McCaffery, James A

    2015-09-01

    There is robust evidence that community health workers (CHWs) in low- and middle-income (LMIC) countries can improve their clients' health and well-being. The evidence on proven strategies to enhance and sustain CHW performance at scale, however, is limited. Nevertheless, CHW stakeholders need guidance and new ideas, which can emerge from the recognition that CHWs function at the intersection of two dynamic, overlapping systems - the formal health system and the community. Although each typically supports CHWs, their support is not necessarily strategic, collaborative or coordinated. We explore a strategic community health system partnership as one approach to improving CHW programming and performance in countries with or intending to mount large-scale CHW programmes. To identify the components of the approach, we drew on a year-long evidence synthesis exercise on CHW performance, synthesis records, author consultations, documentation on large-scale CHW programmes published after the synthesis and other relevant literature. We also established inclusion and exclusion criteria for the components we considered. We examined as well the challenges and opportunities associated with implementing each component. We identified a minimum package of four strategies that provide opportunities for increased cooperation between communities and health systems and address traditional weaknesses in large-scale CHW programmes, and for which implementation is feasible at sub-national levels over large geographic areas and among vulnerable populations in the greatest need of care. We postulate that the CHW performance benefits resulting from the simultaneous implementation of all four strategies could outweigh those that either the health system or community could produce independently. The strategies are (1) joint ownership and design of CHW programmes, (2) collaborative supervision and constructive feedback, (3) a balanced package of incentives, and (4) a practical monitoring

  5. Results of Iris-Claw Intraocular Lens Implantation in Aphakia

    Directory of Open Access Journals (Sweden)

    Mehmet Tahir Şam

    2014-12-01

    Full Text Available Objectives: To evaluate the visual outcomes and complications of iris-claw intraocular lenses (ICIOL implanted in cases of aphakia or in cataract surgery with insufficient capsule support. Material and Method: In this retrospective study, we reviewed the medical records of 34 eyes of 34 patients who had undergone ICIOL implantation with a minimum follow-up of 12 months in Bucak State Hospital and in a private hospital between November 2007 and November 2012. Results: Twenty-one eyes with complicated cataract accompanied by zonular deficiency, 8 eyes with aphakia, and 5 eyes with dislocated IOL were operated and ICIOL implanted. Mean preoperative BCVA was 1.46±1.05 LogMAR and postoperative BCVA was 0.20±0.21 LogMAR. There was an improvement in visual acuity in 31 eyes of the 34 patients, and 29 of them had a visual acuity better than 6/12 postoperatively. Mean postoperative spherical equivalent (SE was -0.76±0.94 D, and deviation from estimated SE was -0.26±0.94 D. Mean preoperative astigmatism was -1.36±0.77 Cyl D and mean postoperative astigmatism was -0.98±0.82 Cyl D. In second postoperative month, one case had a pupillary block glaucoma due to the closure of peripheral iridotomy, and after ND-YAG laser treatment, intraocular pressure return to normal value. One eye had iris pigment precipitates on the ICIOL in early postoperative period, and in one case, there was a pupillary ovalization. Three months after a cataract surgery, retinal detachment developed in one eye of a patient who had a history of severe ocular trauma; anterior vitrectomy and ICIOL implantation were performed. Visual acuity remained unchanged after a successful pars plana vitrectomy operation. Conclusion: Iris-claw lenses provide fairly good visual outcomes in aphakic eyes without capsular support and in challenging cataract cases with zonular deficiency. They are safe regarding complications when compared to other alternative intraocular lens implantation methods

  6. Voyager IRIS Measurements of Triton's Thermal Emission: Impllications for Pluto?

    Science.gov (United States)

    Stansberry, John A.; Spencer, John; Linscott, Ivan

    2015-11-01

    The New Horizons Pluto encounter data set includes unique observations obtained using the Radio Science experiment to measure the night-side thermal emission at centimeter wavelengths, well beyond the emission peak (in the 70 to 100 micron range). 26 years ago the Voyager 2 Infrared Interferometer Spectrometer (IRIS) obtained spectra in the 30 - 50 micron wavelength range to try and detect thermal emission from Pluto's sibling, Triton. Conrath etal. (1989) analyzed 16 of the IRIS spectra of Triton's dayside and derived a weak limit of 36 K - 41 K. We have analysed those, and an additional 75 spectra, to refine the limits on the temperature of Triton's surface, and to explore diurnal differences in the thermal emission. Triton results from other Voyager instruments provide important constraints on our interpretation of the IRIS data, as do Spitzer measurements of Pluto's thermal emission.For unit-emissivity, average temperature is 34 K, inconsistent with the pressure of Triton's atmosphere (13 - 19 microbar), the presence of beta-phase nitrogen ice on the surface, and the likely presence ofwarm regions on the surface. The atmospheric pressure requires nitrogen ice temperatures of 37.4 K - 38.1 K, which in turn requires emissivity of 0.31--0.53. Such a low emissivity in this spectral region might be expected if the surface is dominated by nitrogen or methane ice. Averages of data subsets show evidence for brightness temperature variations across Triton's surface. Surprisingly, the data seem to indicate that Triton's nightside equatorial region was warmer than on the dayside.These Voyager results for Triton provide a useful context for interpreting New Horizons and ALMA observations of emission from Pluto in the sub-millimeter and centimeter region. JWST will be capable of detecting Triton's and Pluto's 10 - 28 micron thermal emission, although scattered light from Neptune may be an issue for the Triton. Combined with new capabilities of ALMA to measure the sub

  7. Computer Models for IRIS Control System Transient Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gary D. Storrick; Bojan Petrovic; Luca Oriani

    2007-01-31

    This report presents results of the Westinghouse work performed under Task 3 of this Financial Assistance Award and it satisfies a Level 2 Milestone for the project. Task 3 of the collaborative effort between ORNL, Brazil and Westinghouse for the International Nuclear Energy Research Initiative entitled “Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor” focuses on developing computer models for transient analysis. This report summarizes the work performed under Task 3 on developing control system models. The present state of the IRIS plant design – such as the lack of a detailed secondary system or I&C system designs – makes finalizing models impossible at this time. However, this did not prevent making considerable progress. Westinghouse has several working models in use to further the IRIS design. We expect to continue modifying the models to incorporate the latest design information until the final IRIS unit becomes operational. Section 1.2 outlines the scope of this report. Section 2 describes the approaches we are using for non-safety transient models. It describes the need for non-safety transient analysis and the model characteristics needed to support those analyses. Section 3 presents the RELAP5 model. This is the highest-fidelity model used for benchmark evaluations. However, it is prohibitively slow for routine evaluations and additional lower-fidelity models have been developed. Section 4 discusses the current Matlab/Simulink model. This is a low-fidelity, high-speed model used to quickly evaluate and compare competing control and protection concepts. Section 5 describes the Modelica models developed by POLIMI and Westinghouse. The object-oriented Modelica language provides convenient mechanisms for developing models at several levels of detail. We have used this to develop a high-fidelity model for detailed analyses and a faster-running simplified model to help speed the I&C development process

  8. Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study Configuração da íris em platô em olhos com seio camerular estreito: um estudo ultrabiomicroscópico

    Directory of Open Access Journals (Sweden)

    Alberto Diniz Filho

    2010-04-01

    Full Text Available PURPOSE: To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. METHODS: Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration or partially absent (incomplete plateau iris configuration ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 µm from the scleral spur; peripheral iris thickness at 500 µm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. RESULTS: Plateau iris configuration was found in 33 eyes of 20 (10.2% out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3% out of 32 patients with acute primary angleclosure. Seventeen (77.3% patients with plateau iris configuration were female and 5 (22.7% male. Twenty-three (62.2% out of 37 eyes had complete plateau iris configuration, and 14 (37.8% had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration

  9. The effect of gender and iris color on the dark-adapted pupil diameter.

    Science.gov (United States)

    Bradley, Jay C; Bentley, Karl C; Mughal, Aleem I; Bodhireddy, Hari; Young, Rockefeller S L; Brown, Sandra M

    2010-08-01

    The aims of this study were to assess the utility of digital color sensing to quantify iris color using digital photographs and to determine whether gender or iris color affects the dark-adapted pupil diameter (DAPD). Subjects aged 18-80 years (N = 263) with no eye disease had their right DAPD measured after 2 min of dark adaptation at 1 lux using the NeurOptics pupillometer. A high-resolution digital slit lamp photograph of the iris was taken, and iris color was subjectively classified as blue, blue-green, green-brown, light brown, or dark brown. The digital photographs were objectively measured on-screen with the Minolta TV Color Analyzer II using the Commission Internationale de l'Eclairage system of color description. Regression analyses were performed to identify correlations between subjective iris color, Commission Internationale de l'Eclairage measurements, and DAPD. Gender and iris color had no effect on the DAPD. The Minolta TV Color Analyzer could discriminate all blue eyes (blue and blue-green) from all brown eyes (light and dark) but could not distinguish between shades of blue or shades of brown. Green-brown irises had no unique chromatic properties and could not be distinguished from other colors using our technique of digital color analysis. The Minolta device was simple and efficient to use. Contrary to long-held beliefs, female patients and blue-eyed patients do not have larger DAPD. Digital color sensing is a useful technique for objectively describing iris color.

  10. Associations of iris structural measurements in a Chinese population: the Singapore Chinese Eye Study.

    Science.gov (United States)

    Sng, Chelvin C; Allen, John C; Nongpiur, Monisha E; Foo, Li-Lian; Zheng, Yingfeng; Cheung, Carol Y; He, Mingguang; Friedman, David S; Wong, Tien Y; Aung, Tin

    2013-04-23

    We determined the ocular biometric and demographic factors associated with iris parameters in Singaporean Chinese persons from a population-based sample. Subjects were participants in the Singapore Chinese Eye Study, a population-based cross-sectional study of eye disease. Anterior segment optical coherence tomography images were analyzed using customized software to measure iris thickness at 750 μm from the scleral spur (IT750), iris area (I-Area), and iris curvature (I-Curv). Regression analyses were performed to assess the association between iris measurements with a range of demographic and ocular variables. The contribution of each independent variable to the iris parameter of interest was determined sequentially using a stepwise selection algorithm. We included 1473 participants with a mean age of 57.7 + 8.68 years, and 50.6% were men. The mean IT750, I-Area, and I-Curv were 0.46 ± 0.10 mm, 1.49 ± 0.24 mm(2), and 0.25 ± 0.13 mm, respectively. Statistical regression models, including a range of demographic and ocular parameters, explained 59.3%, 41.9%, and 34.3% of the variability in I-Curv, IT750, and I-Area, respectively. Angle opening distance at 750 μm from the scleral spur (AOD750) was the single factor associated most strongly with I-Curv, and explained 46.6% of its variation. A significant proportion of the variation in iris area, curvature, and thickness was not explained by other ocular and demographic parameters. Iris curvature was associated strongly with angle width, and of all parameters investigated, AOD750 was most highly correlated with iris curvature.

  11. PARS PLANA VITRECTOMY THROUGH A CUSTOM FLEXIBLE IRIS PROSTHESIS.

    Science.gov (United States)

    Toygar, Okan; Snyder, Michael E; Riemann, Christopher D

    2016-08-01

    To demonstrate the outcomes of pars plana vitrectomy in patients with custom flexible iris prosthesis (CFIP). The medical records of patients who underwent CFIP placement were retrospectively reviewed. Patients who underwent pars plana vitrectomy concurrent with or after placement of CFIP were identified. Preoperative, intraoperative, and postoperative parameters were analyzed. Surgeons were surveyed regarding the technical aspects of the vitreoretinal surgery. Outcome measures included: anatomic success, complications, surgeon-rated ease of visualization through CFIP during pars plana vitrectomy, and Snellen best-corrected visual acuity. Twenty-four surgeries were performed in 20 eyes of 20 patients. Postoperative best-corrected visual acuity improved in 11 eyes (55%), remained unchanged in 5 eyes (25%), and declined in 4 eyes (20%) after a mean follow-up of 16.1 ± 16.\

  12. IRIS DMC products help explore the Tohoku earthquake

    Science.gov (United States)

    Trabant, C.; Hutko, A. R.; Bahavar, M.; Ahern, T. K.; Benson, R. B.; Casey, R.

    2011-12-01

    Within two hours after the great March 11, 2011 Tohoku earthquake the IRIS DMC started publishing automated data products through its Searchable Product Depository (SPUD), which provides quick viewing of many aspects of the data and preliminary analysis of this great earthquake. These products are part of the DMC's data product development effort intended to serve many purposes: stepping-stones for future research projects, data visualizations, data characterization, research result comparisons as well as outreach material. Our current and soon-to-be-released products that allow users to explore this and other global M>6.0 events include 1) Event Plots, which are a suite of maps, record sections, regional vespagrams and P-coda stacks 2) US Array Ground Motion Visualizations that show the vertical and horizontal global seismic wavefield sweeping across US Array including minor and major arc surface waves and their polarizations 3) back-projection movies that show the time history of short-period energy from the rupture 4) R1 source-time functions that show approximate duration and source directivity and 5) aftershock sequence maps and statistics movies based on NEIC alerts that self-update every hour in the first few days following the mainshock. Higher order information for the Tohoku event that can be inferred based on our products which will be highlighted include a rupture duration of order 150 sec (P-coda stacks, back-projections, R1 STFs) that ruptured approximately 400 km along strike primarily towards the south (back-projections, R1 STFs, aftershock animation) with a very low rupture velocity (back-projections, R1 STFs). All of our event-based products are automated and consistently produced shortly after the event so that they may serve as familiar baselines for the seismology research community. More details on these and other existing products are available at: http://www.iris.edu/dms/products/

  13. Information analysis of iris biometrics for the needs of cryptology key extraction

    Directory of Open Access Journals (Sweden)

    Adamović Saša

    2013-01-01

    Full Text Available The paper presents a rigorous analysis of iris biometric information for the synthesis of an optimized system for the extraction of a high quality cryptology key. Estimations of local entropy and mutual information were identified as segments of the iris most suitable for this purpose. In order to optimize parameters, corresponding wavelets were transformed, in order to obtain the highest possible entropy and mutual information lower in the transformation domain, which set frameworks for the synthesis of systems for the extraction of truly random sequences of iris biometrics, without compromising authentication properties. [Projekat Ministarstva nauke Republike Srbije, br. TR32054 i br. III44006

  14. Immunocytochemical localisation of collagens (I-V) in the human iris.

    Science.gov (United States)

    Konstas, A G; Marshall, G E; Lee, W R

    1990-01-01

    In this study we investigated the distribution of collagen types I-V in the human iris at the fine-structural level using cryoultramicrotomy and London Resin White plastic embedding. Collagen type I was shown to be present in the basement membrane of iris vessels, in contrast to type III, which was absent; both types I and III were present in the iris stroma. Collagen type IV was a major component of basement membranes of vascular cells, myoepithelial cells, fibroblasts and epithelial cells. Types II and V were absent. Both cryo and plastic embedding techniques produced closely comparable results.

  15. Fysioterapia miesten seksuaalitoimintahäiriöiden hoitomenetelmänä : Kirjallisuuskatsaus

    OpenAIRE

    Huhtala, Teija

    2011-01-01

    Opinnäytetyössä laadittu kirjallisuuskatsaus kokosi yhteen näyttöön perustuvan tiedon fysioterapiasta miesten seksuaalitoimintahäiriöiden hoitomenetelmänä. Kirjallisuuskatsauksessa tarkasteltiin, minkälaisten seksuaalitoimintahäiriöiden hoidossa fysioterapiaa oli käytetty ja minkälaista kyseinen fysioterapia oli ollut. Lisäksi selvitettiin, mikä oli ollut seksuaalitoimintahäiriöiden hoidossa käytetyn fysioterapian vaikutus kyseisiin ongelmiin. Opinnäytetyöhön sisältyi myös seksuaalitoimintahä...

  16. The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR): A High Speed, Multispectral, Thermal Instrument Development in Support of HyspIRI-TIR

    Science.gov (United States)

    Hook, Simon

    2011-01-01

    The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). The HyspIRI mission was recommended by the National Research Council Decadal Survey and includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. The HyspIRI TIR system will have 60m ground resolution, better than 200mK noise equivalent delta temperature (NEDT), 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. PHyTIR addresses the technology readiness level (TRL) of certain key subsystems of the TIR imager, primarily the detector assembly and scanning mechanism. PHyTIR will use Mercury Cadmium Telluride (MCT) technology at the focal plane and operate in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence allowing the high data rates needed for the 5 day repeat. PHyTIR will also demonstrate a newly developed interferometeric metrology system. This system will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  17. Image Quality Assessment for Fake Biometric Detection: Application to Iris, Fingerprint, and Face Recognition.

    Science.gov (United States)

    Galbally, Javier; Marcel, Sébastien; Fierrez, Julian

    2014-02-01

    To ensure the actual presence of a real legitimate trait in contrast to a fake self-manufactured synthetic or reconstructed sample is a significant problem in biometric authentication, which requires the development of new and efficient protection measures. In this paper, we present a novel software-based fake detection method that can be used in multiple biometric systems to detect different types of fraudulent access attempts. The objective of the proposed system is to enhance the security of biometric recognition frameworks, by adding liveness assessment in a fast, user-friendly, and non-intrusive manner, through the use of image quality assessment. The proposed approach presents a very low degree of complexity, which makes it suitable for real-time applications, using 25 general image quality features extracted from one image (i.e., the same acquired for authentication purposes) to distinguish between legitimate and impostor samples. The experimental results, obtained on publicly available data sets of fingerprint, iris, and 2D face, show that the proposed method is highly competitive compared with other state-of-the-art approaches and that the analysis of the general image quality of real biometric samples reveals highly valuable information that may be very efficiently used to discriminate them from fake traits.

  18. Fusing iris and palmprint at image level for multi-biometrics verification

    Science.gov (United States)

    Liu, Jingwang; Hou, Yan; Wang, Jingyan; Li, Yongping; Wang, Quanquan; Man, Jiaju; Xie, Honglan; He, Jianhua

    2011-12-01

    The phase-based image matching is effective for both iris and palm recognition tasks. Hence, we can expect that the approach may be useful for multimodal biometric system having palmprint and iris recognition capabilities. This paper investigates the fusion of palmprint and iris biometric at image level. A new image fusion algorithm named Baud limited image product (BLIP) especially for phase-based image matching is proposed. Based on this, a new multi-biometric fusion scheme at image level that combines BLIP and phase-based image matching is proposed. The effective region of iris and palm images are first extracted respectively, then they are fused into one small size image using BLIP, finally matched with the template using phase-based image matching to get a score. The experimental results show that this new scheme can not only improve the system accuracy performance, but also reduce the memory size used to store the template and time consumed by the matching.

  19. Novel Iris Biometric Watermarking Based on Singular Value Decomposition and Discrete Cosine Transform

    Directory of Open Access Journals (Sweden)

    Jinyu Lu

    2014-01-01

    Full Text Available A novel iris biometric watermarking scheme is proposed focusing on iris recognition instead of the traditional watermark for increasing the security of the digital products. The preprocess of iris image is to be done firstly, which generates the iris biometric template from person's eye images. And then the templates are to be on discrete cosine transform; the value of the discrete cosine is encoded to BCH error control coding. The host image is divided into four areas equally correspondingly. The BCH codes are embedded in the singular values of each host image's coefficients which are obtained through discrete cosine transform (DCT. Numerical results reveal that proposed method can extract the watermark effectively and illustrate its security and robustness.

  20. IRIS Toxicological Review of Trichloroacetic Acid (TCA) (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Trichloroacetic Acid (TCA), that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development ...

  1. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl Ether (Egbe) (External Review Draft)

    Science.gov (United States)

    EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of ethylene glycol monobutyl ether that will appear on the Integrated Risk Information System (IRIS) database.

  2. [Iris abscess after bacterial endocarditis in a patient with leukaemia. Differential diagnosis].

    Science.gov (United States)

    Manrique Lipa, R; González Sánchez, E; Asencio Duran, M; Gonzalez-Peramato, P; Fonseca Santodomingo, A

    2014-04-01

    To report a case of iris abscess due to bacterial endocarditis. A 46-year-old male under diagnosis of promielocitic leukemia and endocarditis presented with decreased vision in left eye (OS). Ophthalmic exploration revealed iris abscess and hypopyon with fibrinous exudate in iris of the left eye and tyndall +1 in right eye (OD). Blood culture and anterior chamber paracentesis was positive for methicillin-sensitive Staphylococcus aureus and negative for blastic cells in citology. Treatment with systemic antibiotic was initiated with total resolution of inflammation. Iris abscess is an unusual septic focus in bacterial endocarditis. It is crucial to rule out an extramedullary metastasis in a patient with leukemia due to the general prognosis. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  3. High Performance and Accurate Change Detection System for HyspIRI Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose novel and high performance change detection algorithms to process HyspIRI data, which have been used for monitoring changes in vegetation, climate,...

  4. Nimbus-4 Infrared Interferometer Spectrometer (IRIS) Level 1 Radiance Data V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Nimbus-4 Infrared Interferometer Spectrometer (IRIS) Level 1 Radiance Data contain thermal emissions of the Earth's atmosphere at wave numbers between 400 and...

  5. IRIS/Nimbus-4 Level 1 Radiance Data V001 (IRISN4RAD) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Nimbus-4 Infrared Interferometer Spectrometer (IRIS) Level 1 Radiance Data contain thermal emissions of the Earth's atmosphere at wave numbers between 400 and...

  6. RE: Request for Correction - SAB Workgroup Review of Draft IRIS Assessment for Inorganic Arsenic

    Science.gov (United States)

    Request from Lynn Bergeson for the correction of information in the draft EPA document Toxicological Review of Inorganic Arsenic: In Support of the Summary Information on the Integrated Risk Information System (IRIS).

  7. A new species of the genus Iris L. (Iridaceae Juss. from the Ferghana Valley

    Directory of Open Access Journals (Sweden)

    K. Sh. Tojibaev

    2015-03-01

    Full Text Available A new species of Iridaceae, Iris austrotschatkalica Tojibaev, F. Karim. et Turgunov from Fergana valley is described. A morphological description is given and differences from related species are discussed.

  8. IRIS Toxicological Review of Hydrogen Cyanide and Cyanide Salts (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Hydrogen Cyanide (HCN) and Cyanide Salts, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS As...

  9. IRIS Toxicological Review of Dichloromethane (Methylene Chloride) (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Dichloromethane, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Proc...

  10. Infiltration of Plasma Cells in the Iris of Children With ANA-Positive Anterior Uveitis

    NARCIS (Netherlands)

    Kalinina Ayuso, Viera; van Dijk, Marijke R; de Boer, Joke H

    2015-01-01

    PURPOSE: We investigated inflammatory cell infiltrates in iris biopsies in uveitis associated with juvenile idiopathic arthritis (JIA) in comparison with other pediatric uveitis entities and noninflammatory pediatric controls. METHODS: Iridectomy specimens were obtained during elective

  11. Led-lamppujen aiheuttamat sähkömagneettiset häiriöt

    OpenAIRE

    Leino, Juhani

    2015-01-01

    Tässä opinnäytetyössä tutkittiin tavanomaiseen valaistuskäyttöön tarkoitettuja E27-kantaisia led-lamppuja ja niiden aiheuttamia sähkömagneettisia häiriöitä sekä niiden häiriöiden sietokykyä. Lampuille tehtiin säteilevien ja johtuvien häiriöiden mittauksia, sekä lamppujen häiriöiden sietokykyä testattiin transsienttipurskeen ja syöksyaallon sietotesteillä. Mittaukset tehtiin Satakunnan ammattikorkeakoulun Rauman yksikön EMC-laboratoriossa. Mittauksista voitiin todeta, että vaikka CE-hyväk...

  12. Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis.

    Science.gov (United States)

    Aptel, Florent; Denis, Philippe

    2010-01-01

    To describe a method using anterior segment optical coherence tomography (AS OCT) for estimating iris volume. To quantify changes in iris volume induced by pharmacologic mydriasis in narrow-angle eyes predisposed to angle-closure compared with normal open-angle eyes. Cross-sectional study. Thirty fellow eyes of 30 patients who had an episode of primary acute angle-closure and 30 eyes of 30 normal age- and gender-matched subjects with open angles. All fellow eyes had a patent laser peripheral iridotomy. Iris volume and all biometric measurements were performed before and after instillation of 1% tropicamide and at least 1 week later 10% phenylephrine. Iris volume was estimated using AS OCT radial sections of the iris and a customized image-processing software. Iris volume, pupil diameter, angle configuration including angle opening distance at 500 mum (AOD 500) and trabecular-iris space at 500 mum (TISA 500), AS OCT anterior chamber depth, and A-scan ultrasonography axial length before and after pupil dilation. Iris volumes measured before dilation of the pupil were 44.94+/-2.1 mm(3) and 44.29+/-3.9 mm(3) in the fellow eyes and open-angle eyes, respectively, which was not significantly different (P>0.1). Thirty minutes after instillation of 1% tropicamide, mean iris volume increased significantly in the fellow eyes (from 44.94+/-2.1 mm(3) to 49.92+/-2.9 mm(3); Piris volume after pupil dilation were eyes predisposed to angle-closure compared with open-angle eyes (P = 0.008), larger pupil diameter (P = 0.02), and brown eyes (P = 0.01). Relative iris volume increase was correlated significantly with AOD 500 and TISA 500 relative decrease in the narrow-angle group (Piris volume may be estimated with AS OCT. The iris volume increases after pupil dilation in narrow-angle eyes predisposed to acute angle closure. In those patients, this biometric change is associated with a narrowing of the angle despite a patent laser peripheral iridotomy. The author(s) have no proprietary

  13. Comparison of GPS TEC variations with Holt-Winter method and IRI-2012 over Langkawi, Malaysia

    Science.gov (United States)

    Elmunim, N. A.; Abdullah, M.; Hasbi, A. M.; Bahari, S. A.

    2017-07-01

    The Total Electron Content (TEC) is the ionospheric parameter that has the main effect on radio wave propagation. Therefore, it is crucial to evaluate the performance of the TEC models for the further improvement of the ionospheric modelling in equatorial regions. This work presents an analysis of the TEC, derived from the GPS Ionospheric Scintillation and TEC Monitor (GISTM) receiver at the Langkawi station, Malaysia, located at the geographic coordinates of 6.19°N, 99.51°E and the geomagnetic coordinates of 3.39°S, 172.42°E. The diurnal, monthly and seasonal variations in 2014 of the observed GPS-TEC were compared with the statistical Holt-Winter method and a recent version of the International Reference Ionosphere model (IRI-2012), using three different topside options of an electron density, which are the IRI-2001, IRI01-corr and NeQuick. The maximum peaks of the GPS-TEC were observed in the post-noon time and the minimum was observed during the early morning time. In addition, in monthly variations the Holt-Winter and the IRI-2012 topside options showed an underestimation that was in agreement with the GPS-TEC, except for the IRI-2001 model which showed an overestimation in June, July and August. Regarding the seasonal variation of the GPS-TEC, the lowest values were observed during summer and it reached its maximum value during the equinox season. The IRI-2001 showed the highest value of percentage deviation compared to the IRI01-corr, NeQuick and Holt-Winter method. Therefore, the accuracy of the models was found to be approximately 95% in the Holt-Winter method, 75% in the IRI01-corr, 73% in the NeQuick and 66% in the IRI-2001 model. Hence, it can be inferred that the Holt-Winter method showed a higher performance and better estimates of the TEC compared to the IRI01-corr and NeQuick, while the IRI-2001 showed a poor predictive performance in the equatorial region over Malaysia.

  14. Long-term results after artificial iris implantation in patients with aniridia.

    Science.gov (United States)

    Rickmann, Annekatrin; Szurman, Peter; Januschowski, Kai; Waizel, Maria; Spitzer, Martin S; Boden, Karl T; Szurman, Gesine B

    2016-07-01

    The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications. In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses. We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average. The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may

  15. The Real-Time IRI: Assimilating Ionosonde and potentially GNSS data

    Science.gov (United States)

    Bilitza, D.; Galkin, I. A.; Huang, X. A.; Reinisch, B. W.; Vesnin, A.

    2016-12-01

    The International Reference Ionosphere (IRI) is a monthly median empirical model that captures the climatologic essence of observational data collected at a large number of ground and space observatories. IRI is the ISO standard for the ionosphere and has proven its ability to describe the ionosphere's climatological behavior in countless comparisons with new and old data sources and in multi-model performance assessments. There is, however, an ever increasing need for the specification of the real-time weather conditions in the ionosphere that may deviate significantly from the monthly average given by IRI. Starting in 2009 the IRI team has convened focused community meetings to discuss the development of a Real-Time IRI model. We will briefly review some of the studies that have used ionosonde and/or GNSS data to update IRI to real-time conditions. The main focus of this presentation is the IRI-based Real Time Assimilating Model (IRTAM) for the F2-peak parameters foF2 and hmF2 developed by Galkin et al. [2012]. IRTAM assimilates ionosonde data from the Global Ionosphere Radio Observatory (GIRO) network [Reinisch and Galkin, 2011] into IRI applying the same mathematical formalism for the global and diurnal representation of foF2/hmF2 that is used in IRI. The most recent version of IRTAM now also includes ionosonde measurements of the bottomside thickness parameter B0 in the real-time assimilation scheme. We will discuss the potential use of GNSS data in the assimilation process which could contribute to a better representation of ionospheric weather in the topside ionosphere. Ionospheric data from GOLD, ICON, and COSMIC-2 will constitute an exciting future data source for the Real-Time IRI. Galkin, I.A., B. W. Reinisch, X. Huang, and D. Bilitza (2012), Assimilation of GIRO Data into a Real-Time IRI, Radio Sci., 47, RS0L07, doi:10.1029/2011RS004952. Reinisch, B.W. and I.A. Galkin (2011), Global Ionospheric Radio Observatory (GIRO), Earth Planets Space, 63(4), 377

  16. A Novel Edge-Map Creation Approach for Highly Accurate Pupil Localization in Unconstrained Infrared Iris Images

    Directory of Open Access Journals (Sweden)

    Vineet Kumar

    2016-01-01

    Full Text Available Iris segmentation in the iris recognition systems is a challenging task under noncooperative environments. The iris segmentation is a process of detecting the pupil, iris’s outer boundary, and eyelids in the iris image. In this paper, we propose a pupil localization method for locating the pupils in the non-close-up and frontal-view iris images that are captured under near-infrared (NIR illuminations and contain the noise, such as specular and lighting reflection spots, eyeglasses, nonuniform illumination, low contrast, and occlusions by the eyelids, eyelashes, and eyebrow hair. In the proposed method, first, a novel edge-map is created from the iris image, which is based on combining the conventional thresholding and edge detection based segmentation techniques, and then, the general circular Hough transform (CHT is used to find the pupil circle parameters in the edge-map. Our main contribution in this research is a novel edge-map creation technique, which reduces the false edges drastically in the edge-map of the iris image and makes the pupil localization in the noisy NIR images more accurate, fast, robust, and simple. The proposed method was tested with three iris databases: CASIA-Iris-Thousand (version 4.0, CASIA-Iris-Lamp (version 3.0, and MMU (version 2.0. The average accuracy of the proposed method is 99.72% and average time cost per image is 0.727 sec.

  17. Impact of the immune reconstitution inflammatory syndrome (IRIS) on mortality and morbidity in HIV-infected patients in Mexico.

    Science.gov (United States)

    Hoyo-Ulloa, Irma; Belaunzarán-Zamudio, Pablo F; Crabtree-Ramirez, Brenda; Galindo-Fraga, Arturo; Pérez-Aguinaga, María Eugenia; Sierra-Madero, Juan G

    2011-06-01

    To estimate the impact of immune reconstitution inflammatory syndrome (IRIS) on morbidity and mortality in patients starting highly-active antiretroviral therapy (HAART). A retrospective cohort study of HIV-positive patients starting HAART was conducted at a tertiary care referral center in Mexico City. We estimated the incidence of IRIS, hospitalizations and death rates during the first 2 years of HAART. The relative risk of death (RR) and hospitalization for patients with IRIS were adjusted for relevant covariates using regression methods. During the 2-year follow-up period, 27% of patients developed IRIS (14 IRIS cases per 100 person-years). The relative risk of death among patients who developed IRIS was 3 times higher (95% confidence interval (CI) 1.19-7.65, p = 0.03). After adjusting for previous opportunistic infections we still observed a higher death rate among patients with IRIS (RR 2.3, 95% CI 0.9-5.9, p=0.09). An effect modification of IRIS over mortality was observed by previous opportunistic infection. IRIS-associated mortality is strongly confounded by previous opportunistic infection. Patients with AIDS who eventually developed IRIS had the highest risk of death at the 2-year follow-up. Copyright © 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  18. Bilateral acute depigmentation of the iris (BADI): first reported case in Brazil

    OpenAIRE

    Maestrini,Heloisa Andrade; Maestrini, Angela Andrade; Machado,Danuza de Oliveira; Santos,Daniel Vitor Vasconcelos; Almeida, Homero Gusmão de

    2013-01-01

    Bilateral acute depigmentation of the iris (BADI) is a recently described entity characterized by acute onset of pigment dispersion in the anterior chamber, depigmentation of the iris, and heavy pigment deposition in the anterior chamber angle. Involvement is always bilateral, simultaneous, and symmetrical. We report the case of a 61-year-old man who presented with bilateral ocular pain, red eyes, and severe photophobia. Examination revealed a dense Krukenberg spindle, heavy pigment dispersio...

  19. Latitudinal characteristics of GPS derived ionospheric TEC: a comparative study with IRI 2012 model

    Directory of Open Access Journals (Sweden)

    Monti Chakraborty

    2014-10-01

    Full Text Available The present study investigates the variation of Total Electron Content (TEC using Global Positioning System (GPS satellites from four equatorial to mid-latitudes stations over a period of one year. The stations are Port Blair (11.63°N, 92.70°E, Agartala (23.75°N, 91.25°E, Lhasa (29.65°N, 91.10°E and Urumqi (43.46°N, 87.16°E. The diurnal, monthly and seasonal variations of TEC have been explored to study its latitudinal characteristics. Analysis of TEC data from these stations reveals the characteristics of latitudinal variation of Equatorial Ionospheric Anomaly (EIA. To validate the latest IRI 2012 model, the monthly and seasonal variations of GPS-TEC at all the four stations have been compared with the model for three different topside options of electron density, namely, NeQuick, IRI-01-corr and IRI-2001. TEC predictions from IRI-2001 top side electron density option using IRI 2012 model overestimates the observed TEC especially at the low latitudes. TEC from IRI- NeQuick and IRI-01-corr options shows a tendency to underestimate the observed TEC during the day time particularly in low latitude region in the high solar activity period. The agreement between the model and observed values are reasonable in mid latitude regions. However, a discrepancy between IRI 2012 derived TEC with the ground based observations at low latitude regions is found. The discrepancy appears to be higher in low-latitude regions in comparison to mid latitude regions. It is concluded that largest discrepancy in TEC occur as a result of poor estimation of the hmF2 and foF2 from the coefficients.

  20. Improvement of Varioptic's liquid lens based on electrowetting: how to obtain a short response time and its application in the design of a high resolution iris biometric system

    Science.gov (United States)

    Burger, Benjamin; Meimon, Serge C.; Petit, Cyril; Nguyen, Minh Chau

    2015-02-01

    This communication presents the results obtained for decreasing the response time of electrowetting-based real time focus correctors (liquid lenses). In order to provide a compact iris biometric system demonstrator, we have achieved a response time at 90% of 7.5 ms for a change in focalization from 0 diopter to 10 diopter with a liquid lens having an aperture of 1.9 mm. We have used a hydrodynamic fluid reorganization model to predict the features of these fast liquid lenses and evaluated the sensivity of the response time to the different conception parameters.

  1. Nomenclatural types of iberian Irises (Iris and related genera, Iridaceae [Tipos nomenclaturales de lirios ibéricos (Iris y géneros relacionados, Iridaceaae

    Directory of Open Access Journals (Sweden)

    Manuel B. CRESPO VILLALBA

    2012-12-01

    Full Text Available SUMMARY: Nomenclatural types are reported for seventeen taxa belonging to Iris and six related genera, which are accepted in the forthcoming treatment of Iridaceae for Flora iberica. Among them, 13 lectotypes and one neotype are designated for the first time, and three previous typifications are briefly commented. RESUMEN: Se presentan los tipos nomenclaturales de 17 táxones pertenecientes a Iris y otros seis géneros relacionados, que se aceptan en el tratamiento de las Iridaceae para Flora iberica. De ellos, se designan por primera vez 13 lectótipos y un neótipo, y se comentan brevemente tres tipificaciones previas.

  2. Easy access to geophysical data sets at the IRIS Data Management Center

    Science.gov (United States)

    Trabant, C.; Ahern, T.; Suleiman, Y.; Karstens, R.; Weertman, B.

    2012-04-01

    At the IRIS Data Management Center (DMC) we primarily manage seismological data but also have other geophysical data sets for related fields including atmospheric pressure and gravity measurements and higher level data products derived from raw data. With a few exceptions all data managed by the IRIS DMC are openly available and we serve an international research audience. These data are available via a number of different mechanisms from batch requests submitted through email, web interfaces, near real time streams and more recently web services. Our initial suite of web services offer access to almost all of the raw data and associated metadata managed at the DMC. In addition, we offer services that apply processing to the data before it is sent to the user. Web service technologies are ubiquitous with support available in nearly every programming language and operating system. By their nature web services are programmatic interfaces, but by choosing a simple subset of web service methods we make our data available to a very broad user base. These interfaces will be usable by professional developers as well as non-programmers. Whenever possible we chose open and recognized standards. The data returned to the user is in a variety of formats depending on type, including FDSN SEED, QuakeML, StationXML, ASCII, PNG images and in some cases where no appropriate standard could be found a customized XML format. To promote easy access to seismological data for all researchers we are coordinating with international partners to define web service interfaces standards. Additionally we are working with key partners in Europe to complete the initial implementation of these services. Once a standard has been adopted and implemented at multiple data centers researchers will be able to use the same request tools to access data across multiple data centers. The web services that apply on-demand processing to requested data include the capability to apply instrument corrections and

  3. A hyperspectral imaging system for the evaluation of the human iris spectral reflectance

    Science.gov (United States)

    Di Cecilia, Luca; Marazzi, Francesco; Rovati, Luigi

    2017-02-01

    According to previous studies, the measurement of the human iris pigmentation can be exploited to detect certain eye pathological conditions in their early stage. In this paper, we propose an instrument and a method to perform hyperspectral quantitative measurements of the iris spectral reflectance. The system is based on a simple imaging setup, which includes a monochrome camera mounted on a standard ophthalmic microscope movement controller, a monochromator, and a flashing LED-based slit lamp. To assure quantitative measurements, the system is properly calibrated against a NIST reflectance standard. Iris reflectance images can be obtained in the spectral range 495-795 nm with a resolution of 25 nm. Each image consists of 1280 x 1024 pixels having a spatial resolution of 18 μm. Reflectance spectra can be calculated both from discrete areas of the iris and as the average of the whole iris surface. Preliminary results suggest that hyperspectral imaging of the iris can provide much more morphological and spectral information with respect to conventional qualitative colorimetric methods.

  4. The Priority of Road Rehabilitation in Karanganyar Regency Using IRI Estimation from Roadroid

    Science.gov (United States)

    Achmadi, F.; Suprapto, M.; Setyawan, A.

    2017-02-01

    The IRI (International Roughness Index) is a road roughness index commonly obtained from measured longitudinal road profiles. This is one of the functional performance a surface of road pavement. Therefore, needs to be done evaluation and monitoring periodically to getting priority of road rehabilitation right on target. The IRI standard has commonly been used worldwide for evaluating road system. The Roadroid is an application to measure road quality with a website to view road quality. It is designed for Android smartphones, so we can easily measure and monitor the road and also use the camera for GPS-tagged photo. By using the built-in vibration sensor in smartphones, it is possible to collect IRI value which can be an indicator road conditions. This study attempts to explain the priority of road rehabilitation in Karanganyar Regency. The location of the study focused on a collector street (primary, secondary and locally road). The result of IRI estimation will be combined with other aspects that influences; land use, policy, the connectivity of road and traffic average daily. Based on IRI estimation using Roadroid, the road conditions in Karanganyar Regency can be described 59,60% were good (IRI12).

  5. Age related macular degeneration and sun exposure, iris colour, and skin sensitivity to sunlight

    Science.gov (United States)

    Khan, J C; Shahid, H; Thurlby, D A; Bradley, M; Clayton, D G; Moore, A T; Bird, A C; Yates, J R W

    2006-01-01

    Background/aim It has been suggested that sun exposure may be a risk factor for age related macular degeneration (AMD) and that skin sensitivity to sunlight and iris colour could be confounding factors. The aim was to investigate this further in the white population. Methods 446 cases with end stage AMD were compared with 283 spouse controls. Data on sun exposure, places of residence, iris colour, subjective assessment of change in iris colour, hair colour at age 20, and skin sensitivity were obtained using a questionnaire. Iris colour was graded clinically by comparison with standard photographs. AMD was graded using stereoscopic colour fundus photographs as well as clinical examination and was defined as the presence of geographic atrophy or choroidal neovascularisation. All variables were included in a multiple logistic regression model including age, sex, and smoking. Results There was no association between AMD and sun exposure or related factors except for the suggestion of an association between sunburn prone skin type and geographic atrophy which reached borderline significance. Conclusions No significant association between AMD and sun exposure, iris colour, change in iris colour, or hair colour was demonstrated. PMID:16361662

  6. An Accurate and Efficient User Authentication Mechanism on Smart Glasses Based on Iris Recognition

    Directory of Open Access Journals (Sweden)

    Yung-Hui Li

    2017-01-01

    Full Text Available In modern society, mobile devices (such as smart phones and wearable devices have become indispensable to almost everyone, and people store personal data in devices. Therefore, how to implement user authentication mechanism for private data protection on mobile devices is a very important issue. In this paper, an intelligent iris recognition mechanism is designed to solve the problem of user authentication in wearable smart glasses. Our contributions include hardware and software. On the hardware side, we design a set of internal infrared camera modules, including well-designed infrared light source and lens module, which is able to take clear iris images within 2~5 cm. On the software side, we propose an innovative iris segmentation algorithm which is both efficient and accurate to be used on smart glasses device. Another improvement to the traditional iris recognition is that we propose an intelligent Hamming distance (HD threshold adaptation method which dynamically fine-tunes the HD threshold used for verification according to empirical data collected. Our final system can perform iris recognition with 66 frames per second on a smart glasses platform with 100% accuracy. As far as we know, this system is the world’s first application of iris recognition on smart glasses.

  7. Survey of virus pathogens in gladiolus, iris and tulips in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Ganesh Selvaraj Duraisamy

    2009-01-01

    Full Text Available The occurrence of Bean yellow mosaic virus (BYMV, Cucumber mosaic virus (CMV Tobacco rattle virus (TRV in gladiolus, iris, tulip and Iris yellow spot virus (IYSV in iris was investigated by examining the plants by the means of serological techniques (ELISA. ELISA was applied to determine the presence of BYMV, CMV, TRV infections in both aerial and underground parts of gladiolus, iris, and tulip, and IYSV on the aerial parts of iris, respectively. 262 gladiolus plants were tested. 63.7% was infected by BYMV, 29.4 % by CMV, and 2.7 % by TRV. Out of 180 plants of iris, 1.1% was infected by BYMV, 6.7% by CMV, 2.8% by TRV, and 0% by IYSV. Out of 28 plants of tulip, 28.6% was infected by CMV, and 7.1% by TRV. ELISA proved to be a suitable method for detection of viruses in leaves of these ornamental plants, but it often failed to detect viruses in flowers and corms. A high transmission of BYMV by gladiolus cormlets was also found.

  8. {sup 18}F-FDG PET/CT heterogeneity quantification through textural features in the era of harmonisation programs: a focus on lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lasnon, Charline [University Hospital, Nuclear Medicine Department, Caen (France); Biologie et Therapies Innovantes des Cancers Localement Agressifs, Universite de Caen Normandie, INSERM, Caen (France); Normandie University, Caen (France); Majdoub, Mohamed; Lavigne, Brice; Visvikis, Dimitris [LaTIM, INSERM UMR 1101, Brest (France); Do, Pascal [Thoracic Oncology, Francois Baclesse Cancer Centre, Caen (France); Madelaine, Jeannick [Caen University Hospital, Pulmonology Department, Caen (France); Hatt, Mathieu [LaTIM, INSERM UMR 1101, Brest (France); CHRU Morvan, INSERM UMR 1101, Laboratoire de Traitement de l' Information Medicale (LaTIM), Groupe ' Imagerie multi-modalite quantitative pour le diagnostic et la therapie' , Brest (France); Aide, Nicolas [University Hospital, Nuclear Medicine Department, Caen (France); Biologie et Therapies Innovantes des Cancers Localement Agressifs, Universite de Caen Normandie, INSERM, Caen (France); Normandie University, Caen (France); Caen University Hospital, Nuclear Medicine Department, Caen (France)

    2016-12-15

    Quantification of tumour heterogeneity in PET images has recently gained interest, but has been shown to be dependent on image reconstruction. This study aimed to evaluate the impact of the EANM/EARL accreditation program on selected {sup 18}F-FDG heterogeneity metrics. To carry out our study, we prospectively analysed 71 tumours in 60 biopsy-proven lung cancer patient acquisitions reconstructed with unfiltered point spread function (PSF) positron emission tomography (PET) images (optimised for diagnostic purposes), PSF-reconstructed images with a 7-mm Gaussian filter (PSF{sub 7}) chosen to meet European Association of Nuclear Medicine (EANM) 1.0 harmonising standards, and EANM Research Ltd. (EARL)-compliant ordered subset expectation maximisation (OSEM) images. Delineation was performed with fuzzy locally adaptive Bayesian (FLAB) algorithm on PSF images and reported on PSF{sub 7} and OSEM ones, and with a 50 % standardised uptake values (SUV){sub max} threshold (SUV{sub max50%}) applied independently to each image. Robust and repeatable heterogeneity metrics including 1st-order [area under the curve of the cumulative histogram (CH{sub AUC})], 2nd-order (entropy, correlation, and dissimilarity), and 3rd-order [high-intensity larger area emphasis (HILAE) and zone percentage (ZP)] textural features (TF) were statistically compared. Volumes obtained with SUV{sub max50%} were significantly smaller than FLAB-derived ones, and were significantly smaller in PSF images compared to OSEM and PSF{sub 7} images. PSF-reconstructed images showed significantly higher SUVmax and SUVmean values, as well as heterogeneity for CH{sub AUC}, dissimilarity, correlation, and HILAE, and a wider range of heterogeneity values than OSEM images for most of the metrics considered, especially when analysing larger tumours. Histological subtypes had no impact on TF distribution. No significant difference was observed between any of the considered metrics (SUV or heterogeneity features) that we

  9. Laboratory evaluation of the IriScan prototype biometric identifier

    Energy Technology Data Exchange (ETDEWEB)

    Bouchier, F.; Ahrens, J.S.; Wells, G.

    1996-04-01

    One thing that all access control applications have in common is the need to identify those individuals authorized to gain access to an area. Traditionally, the identification is based on something that person possesses, such as a key or badge, or something they know, such as a PIN or password. Biometric identifiers make their decisions based on the physiological or behavioral characteristics of individuals. The potential of biometrics devices to positively identify individuals has made them attractive for use in access control and computer security applications. However, no systems perform perfectly, so it is important to understand what a biometric device`s performance is under real world conditions before deciding to implement one in an access control system. This paper will describe the evaluation of a prototype biometric identifier provided by IriScan Incorporated. This identifier was developed to recognize individual human beings based on the distinctive visual characteristics of the irises of their eyes. The main goal of the evaluation was to determine whether the system has potential as an access control device within the Department of Energy (DOE). The primary interest was an estimate of the accuracy of the system in terms of false accept and false reject rates. Data was also collected to estimate throughput time and user acceptability. The performance of the system during the test will be discussed. Lessons learned during the test which may aid in further testing and simplify implementation of a production system will also be discussed.

  10. Trauma and Memory in Iris Murdoch's The Italian Girl

    Directory of Open Access Journals (Sweden)

    David Sandor Szoke

    2016-05-01

    Full Text Available The core of this paper is to provide a critical analysis on Iris Murdoch’s The Italian Girl in the light of post-Holocaust studies. This paper’s aim is to identify how the concepts of memory and trauma emerge in Murdoch’s narrative, and how the post-war Jewish guilt and mourning for the dead constitutes a central element of her early novels. Through an extended analysis of The Italian Girl’s two exile characters, this work wishes to connect Murdoch’s ethical concerns on the Holocaust to the problem of the Jewish exile identity, explaining how the notions of survival and memory as well as the dilemma of the acceptance versus rejection of minority identity constitute a central problem in her fiction. In this essay, I also address such concepts as the Freudian ideas of the uncanny and homecoming, demonstrating how the Freudian psychoanalysis and the style of the Gothic novel serve as helpful guides for Murdoch to draw up the psychosis of a post-war world that was shaken by Hitler’s terror and the Holocaust.

  11. Study of mixing process in the IRIS downcomer

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Elizabeth; Montesinos, Maria E.; Garcia, Carlos; Rives, Ronny; Rojas, Leorlen Y., E-mail: ciazbueno@instec.cu, E-mail: mmontesi@instec.cu, E-mail: cgh@instec.cu, E-mail: rsanz@instec.cu, E-mail: leored1984@gmail.com [Instituto Superior de Tecnologias y Ciencias Aplicadas (InSTEC), La Habana (Cuba); Bezerra, Jair L.; Lira, Carlos A.B. de Oliveira, E-mail: jairbezerra@gmail.com, E-mail: cabol@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2015-07-01

    The reactivity of a water cooled reactor is controlled using control rods or boron dilution in water of the primary circuit. The Boron-10 (10B) is an efficient neutron absorber, especially when used in the absorption of thermal neutrons. Transient analysis with disabilities in the homogenization of Boron in PWR reactors becomes important as the boric acid solution is added to the primary circuit coolant in order to help control the fission rate in the reactor core. After reactor shutdown, the Boron present in coolant has the function of maintaining the reactor subcriticality. The aim of this research is to study the Boron homogenization processes in the downcomer of the IRIS nuclear reactor. It was used a test section, which represents a quarter of the interest geometry to harness the domain symmetry. By using the CFX code, the startup and shutdown were simulated in order to analyze the mixing processes in the coolant. It was evaluated the influence in the Boron homogenization of different geometrical configurations such as three different positions of coolant entrance with respect to the core holders and the variation of the dimensions of the DVI lines. This paper also analyze an event of partial loss of coolant because a coolant pump failure. (author)

  12. Screening antioxidant and anticholinesterase potential of Iris albicans extracts

    Directory of Open Access Journals (Sweden)

    Işıl Hacıbekiroğlu

    2015-03-01

    Full Text Available The antioxidant and anticholinesterase activities of the extracts prepared from the rhizomes and flowering aerial parts of Iris albicans were determined in this study. The chloroform extract of the rhizomes was rich in total phenolic contents (431.98 ± 0.49 μgPEs/mg, and the chloroform extract of the aerial parts in total flavonoid contents (663.05 ± 0.32 μgQEs/mg. Although the chloroform extract of the rhizomes exhibited the best antioxidant effect in β -carotene bleaching and CUPRAC methods among the tested extracts at all concentrations, it was found inactive in the metal chelating assay. The methanol extract of the aerial parts indicated moderate metal chelating activity (60% at 100 μg/mL. The chloroform extract of the rhizomes showed moderate anticholinesterase effect at 200 μg/mL. The chloroform extract of the aerial parts showed significantly inhibition against butyrylcholinesterase (78.44 ± 0.51%.

  13. Solar Features

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Collection includes a variety of solar feature datasets contributed by a number of national and private solar observatories located worldwide.

  14. Site Features

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of various site features from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times...

  15. Feature Extraction

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    Feature selection and reduction are key to robust multivariate analyses. In this talk I will focus on pros and cons of various variable selection methods and focus on those that are most relevant in the context of HEP.

  16. An Individualized Representational Intervention to Improve Symptom Management (IRIS) in Older Breast Cancer Survivors: Three Pilot Studies

    Science.gov (United States)

    Heidrich, Susan M.; Brown, Roger L.; Egan, Judith J.; Perez, Oscar A.; Phelan, Cynthia H.; Yeom, Hyune; Ward, Sandra E.

    2009-01-01

    Purpose/Objectives To test the feasibility and acceptability of an individualized representational intervention to improve symptom management (IRIS) in older breast cancer survivors and test the short-term effects of an IRIS on symptom distress. Design Two small randomized clinical trials and one pre-experimental study. Setting Oncology clinic and community. Sample 41 women with breast cancer (aged 65 years and older) in pilot study 1, 20 in pilot study 2, and 21 in pilot study 3. Methods In pilot study 1, women were randomized to the IRIS or usual care control. In pilot study 2, women were randomized to the IRIS or delayed IRIS (wait list) control. In pilot study 3, all women received the IRIS by telephone. Measures were collected at baseline, postintervention, and follow-up (up to four months). Main Research Variables Feasibility, acceptability, symptom distress, symptom management behaviors, symptom management barriers, and quality of life. Findings Across three pilot studies, 76% of eligible women participated, 95% completed the study, 88% reported the study was helpful, and 91% were satisfied with the study. Some measures of symptom distress decreased significantly after the IRIS, but quality of life was stable. Women in the IRIS group changed their symptom management behaviors more than controls. Conclusions Preliminary evidence supports the need for and feasibility of an IRIS. Implications for Nursing Nurses may help older breast cancer survivors manage their numerous chronic symptoms more effectively by assessing women’s beliefs about their symptoms and their current symptom management strategies. PMID:19403441

  17. Nuevos Algoritmos y Ataques a Sistemas de Identificación Biométrica basados en Reconocimiento de Iris

    OpenAIRE

    Santos Sierra, Alberto de; Sánchez Ávila, Carmen; Jara Vera, Vicente

    2008-01-01

    En este trabajo se recogen dos enfoques claramente de_nidos: Primeramente, se propone una mejora a los sistemas actuales de detecci _on de iris, tanto en detecci_on de pupila, como en detecci_on de iris en s__ misma. Dichos algoritmos rompen con el esquema cl_asico de aislamiento de iris, y proponen una nueva idea en este campo. Adem_as, se utilizar_an bases de datos actuales para la evaluaci_on de los resultados. Por otro lado, se presenta un esquema de ataque a un sistema de iris en el que ...

  18. Lithospheric Structure and Dynamics: Insights Facilitated by the IRIS/PASSCAL Facility

    Science.gov (United States)

    Meltzer, A.

    2002-12-01

    Through the development of community-based facilities in portable array seismology, a wide-range of seismic methods are now standard tools for imaging the Earth's interior, extending geologic observations made at the surface to depth. The IRIS/PASSCAL program provides the seismological community with the ability to routinely field experimental programs, from high-resolution seismic reflection profiling of the near surface to lithospheric scale imaging with both active and passive source arrays, to understand the tectonic evolution of continents, how they are assembled, disassembled, and modified through time. As our ability to record and process large volumes of data has improved we have moved from simple 1-D velocity models and 2-D structural cross sections of the subsurface to 3-D and 4-D images to correlate complex surface tectonics to processes in the Earth's interior. Data from individual IRIS/PASSCAL experiments has fostered multidisciplinary studies, bringing together geologists, geochemists, and geophysicists to work together on common problems. As data is collected from a variety of tectonic environments around the globe common elements begin to emerge. We now recognize and study the inherent lateral and vertical heterogeneity in the crust and mantle lithosphere and its role in controlling deformation, the importance of low velocity mobile mantle in supporting topography, and the importance of fluids and fluid migration in magmatic and deformational processes. We can image and map faults, fault zones, and fault networks to study them as systems rather than isolated planes of deformation to better understand earthquake nucleation, rupture, and propagation. An additional benefit of these community-based facilities is the pooling of resources to develop effective and sustainable education and outreach programs. These programs attract new students to pursue careers in earth science, engage the general public in the scientific enterprise, raise the profile of

  19. Comparison between IRI-2012 and GPS-TEC observations over the western Black Sea

    Science.gov (United States)

    Inyurt, Samed; Yildirim, Omer; Mekik, Cetin

    2017-07-01

    The ionosphere is a dynamic layer which generally changes according to radiation emitted by the sun, the movement of the earth around the sun, and sunspot activity. Variations can generally be categorized as regular or irregular variations. Both types of variation have a huge effect on radio wave propagation. In this study, we have focused on the seasonal variation effect, which is one of the regular forms of variation in terms of the ionosphere. We examined the seasonal variation over the ZONG station in Turkey for the year 2014. Our analysis results and IRI-2012 present different ideas about ionospheric activity. According to our analysed results, the standard deviation reached a maximum value in April 2014. However, the maximum standard deviation obtained from IRI-2012 was seen in February 2014. Furthermore, it is clear that IRI-2012 underestimated the VTEC values when compared to our results for all the months analysed. The main source of difference between the two models is the IRI-2012 topside ionospheric representation. IRI-2012 VTEC has been produced as a result of the integration of an electron density profile within altitudinal limits of 60-2000 km. In other words, the main problem with regard to the IRI-2012 VTEC representation is not being situated in the plasmaspheric part of the ionosphere. Therefore we propose that the plasmaspheric part should be taken into account to calculate the correct TEC values in mid-latitude regions, and we note that IRI-2012 does not supply precise TEC values for use in ionospheric studies.

  20. Chronic post-operative iris prosthesis endophthalmitis in a patient with traumatic aniridia: a case report.

    Science.gov (United States)

    Firl, Kevin C; Montezuma, Sandra R

    2016-11-09

    Post-operative endophthalmitis is a serious complication of intraocular surgery which may present acutely or chronically. Chronic post-operative endophthalmitis is characterized by decreased visual acuity, mild pain, and low-grade uveitis several weeks or months after intraocular surgery which may be responsive to corticosteroids, but recur upon tapering. Low virulence organisms such as Propionibacterium acnes are the most common culprit organisms, and treatment most often consists of both intravitreal antibiotic injections and surgery. Aniridia is a condition defined by total or partial loss of the iris and leads to decreased visual quality marked by glare and photophobia. Treatment of complex or severe cases of traumatic aniridia in which surgical repair is difficult may consist of implantation of iris prostheses, devices designed to reduce symptoms of aniridia. Though chronic, post-operative endophthalmitis has been associated with most intraocular surgeries including intraocular lens implantation after cataract removal, it has never been described in a patient with an iris prosthesis. In this case report, we describe the case of a 49 year old, male construction worker with traumatic aniridia who experienced chronic, recurrent low-grade intraocular inflammation and irritation for months after implantation of the Ophtec 311 prosthetic iris. Symptoms and signs of inflammation improved temporarily with sub-Tenon's capsule triamcinolone injections. Ultimately after more than 2 post-operative years, the iris prosthesis was explanted, and intravitreal cultures showed P. acnes growth after 5 days. Intravitreal antibiotics treated the infection successfully. To our knowledge, this is the first reported case of chronic, post-operative endophthalmitis in a patient with an iris prosthesis. Chronic, post-operative endophthalmitis may be a difficult to identify in the context of traumatic aniridia and iris prosthesis implantation due to other potential etiologies of

  1. Classification of iris colour: review and refinement of a classification schema.

    Science.gov (United States)

    Mackey, David A; Wilkinson, Colleen H; Kearns, Lisa S; Hewitt, Alex W

    2011-07-01

    Eye colour or, more accurately, iris colour is one of the most obvious physical characteristics of a person. European parents frequently ask the colour of their newborn's eyes, only to see the iris change dramatically during their child's first year of life. Genetic and epidemiological findings have uncovered further details about the basis for iris colour, which may have important implications for further research and treatment of some eye diseases and ocular characteristics. Surprisingly there is no widely recognized classification system for eye colour. An added difficulty when trying to devise an international system is that subtle differences in colour description exist between languages (e.g. hazel vs. auburn). We reviewed the recent and very early literature pertaining to eye colour classification. Recent genetic investigations of eye colour have tended to either use simple (three-category grading systems) or more complex digital colour grading. We present a nine-category grading system. Categories in this novel schema include: (i) light blue; (ii) darker blue; (iii) blue with brown peripupillary ring; (iv) green; (v) green with brown iris ring; (vi) peripheral green central brown; (vii) brown with some peripheral green; (viii) brown; and (ix) dark brown. Although different observers may categorize a person's eye colour differently, it is generally only by an adjacent category. We also describe a continuum of iris pigmentation from a small ring of brown around the pupil to almost complete brown with small peripheral flecks. Digital publishing and assessment of iris colour will result in more standardized classification of iris colour and investigation of its role in eye disease. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  2. First Demonstration of Ocular Refractive Change Using Blue-IRIS in Live Cats

    Science.gov (United States)

    Savage, Daniel E.; Brooks, Daniel R.; DeMagistris, Margaret; Xu, Lisen; MacRae, Scott; Ellis, Jonathan D.; Knox, Wayne H.; Huxlin, Krystel R.

    2014-01-01

    Purpose. To determine the efficacy of intratissue refractive index shaping (IRIS) using 400-nm femtosecond laser pulses (blue light) for writing refractive structures directly into live cat corneas in vivo, and to assess the longevity of these structures in the eyes of living cats. Methods. Four eyes from two adult cats underwent Blue-IRIS. Light at 400 nm with 100-femtosecond (fs) pulses were tightly focused into the corneal stroma of each eye at an 80-MHz repetition rate. These pulses locally increased the refractive index of the corneal stroma via an endogenous, two-photon absorption process and were used to inscribe three-layered, gradient index patterns into the cat corneas. The optical effects of the patterns were then tracked using optical coherence tomography (OCT) and Shack-Hartmann wavefront sensing. Results. Blue-IRIS patterns locally changed ocular cylinder by −1.4 ± 0.3 diopters (D), defocus by −2.0 ± 0.5 D, and higher-order root mean square (HORMS) by 0.31 ± 0.04 μm at 1 month post-IRIS, without significant changes in corneal thickness or curvature. Refractive changes were maintained for the duration they were tracked, 12 months post-IRIS in one eye, and just more than 3 months in the remaining three eyes. Conclusions. Blue-IRIS can be used to inscribe refractive structures into live cat cornea in vivo that are stable for at least 12 months, and are not associated with significant alterations in corneal thicknesses or radii of curvature. This result is a critical step toward establishing Blue-IRIS as a promising technique for noninvasive vision correction. PMID:24985471

  3. Advanced Instrumentation and Control Methods for Small and Medium Reactors with IRIS Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    J. Wesley Hines; Belle R. Upadhyaya; J. Michael Doster; Robert M. Edwards; Kenneth D. Lewis; Paul Turinsky; Jamie Coble

    2011-05-31

    Development and deployment of small-scale nuclear power reactors and their maintenance, monitoring, and control are part of the mission under the Small Modular Reactor (SMR) program. The objectives of this NERI-consortium research project are to investigate, develop, and validate advanced methods for sensing, controlling, monitoring, diagnosis, and prognosis of these reactors, and to demonstrate the methods with application to one of the proposed integral pressurized water reactors (IPWR). For this project, the IPWR design by Westinghouse, the International Reactor Secure and Innovative (IRIS), has been used to demonstrate the techniques developed under this project. The research focuses on three topical areas with the following objectives. Objective 1 - Develop and apply simulation capabilities and sensitivity/uncertainty analysis methods to address sensor deployment analysis and small grid stability issues. Objective 2 - Develop and test an autonomous and fault-tolerant control architecture and apply to the IRIS system and an experimental flow control loop, with extensions to multiple reactor modules, nuclear desalination, and optimal sensor placement strategy. Objective 3 - Develop and test an integrated monitoring, diagnosis, and prognosis system for SMRs using the IRIS as a test platform, and integrate process and equipment monitoring (PEM) and process and equipment prognostics (PEP) toolboxes. The research tasks are focused on meeting the unique needs of reactors that may be deployed to remote locations or to developing countries with limited support infrastructure. These applications will require smaller, robust reactor designs with advanced technologies for sensors, instrumentation, and control. An excellent overview of SMRs is described in an article by Ingersoll (2009). The article refers to these as deliberately small reactors. Most of these have modular characteristics, with multiple units deployed at the same plant site. Additionally, the topics focus

  4. High-Resolution Studies of Oceanic Spreading Center Volcanic and Hydrothermal Features and Processes - New Insights from Ridge 2000 Program Experiments

    Science.gov (United States)

    Fornari, D. J.

    2011-12-01

    During the past 60 years of research on mid-ocean ridges (MORs) we have exponentially increased our understandings one of the planet's most fundamental features and the myriad processes associated with the transfer of energy from the mantle to the hydrosphere that is focused along accretionary plate boundaries. The past decade's research, implemented by a broad community of scientists in numerous disciplines has yielded a watershed of information that has helped to make both temporal and spatial connections between processes that store and deliver magma to the crust and seafloor, and the consequent hydrothermal and biological phenomena that derive from that energy transfer. Ridge 2000 Program research at each of the three Integrated Study Sites (ISSs) - East Pacific Rise 8-10N, Juan de Fuca - Endeavour Segment, and Eastern Lau Spreading Center - provided an opportunity to coordinate field experiments, laboratory studies and modeling that has lead to new concepts of oceanic spreading center processes. In particular, the latest generation of near-bottom seafloor mapping and sampling systems and a new array of deep submergence vehicles, which include remotely operated vehicles (ROVs) and autonomous underwater vehicles (AUVs), as well more traditional human occupied vehicles (HOVs) like Alvin, have yielded important new views of MOR seafloor. These systems have allowed us to resolve the sub-meter topography of specific volcanic and hydrothermal features and relate them to distributions of hydrothermal communities, chemical variations among hydrothermal chimneys and their fluid effluent, and to axial structures that are surface manifestations of tectonic processes. In situ chemical, biological and microbial studies carried out during the past decade have increasingly shown how tightly linked chemical and biological processes are within MOR hydrothermal communities. Previous hypotheses concerning frequency of magmatism and volcanic eruptions that have related

  5. Observing System Simulation Experiment (OSSE) for the HyspIRI Spectrometer Mission

    Science.gov (United States)

    Turmon, Michael J.; Block, Gary L.; Green, Robert O.; Hua, Hook; Jacob, Joseph C.; Sobel, Harold R.; Springer, Paul L.; Zhang, Qingyuan

    2010-01-01

    The OSSE software provides an integrated end-to-end environment to simulate an Earth observing system by iteratively running a distributed modeling workflow based on the HyspIRI Mission, including atmospheric radiative transfer, surface albedo effects, detection, and retrieval for agile exploration of the mission design space. The software enables an Observing System Simulation Experiment (OSSE) and can be used for design trade space exploration of science return for proposed instruments by modeling the whole ground truth, sensing, and retrieval chain and to assess retrieval accuracy for a particular instrument and algorithm design. The OSSE in fra struc ture is extensible to future National Research Council (NRC) Decadal Survey concept missions where integrated modeling can improve the fidelity of coupled science and engineering analyses for systematic analysis and science return studies. This software has a distributed architecture that gives it a distinct advantage over other similar efforts. The workflow modeling components are typically legacy computer programs implemented in a variety of programming languages, including MATLAB, Excel, and FORTRAN. Integration of these diverse components is difficult and time-consuming. In order to hide this complexity, each modeling component is wrapped as a Web Service, and each component is able to pass analysis parameterizations, such as reflectance or radiance spectra, on to the next component downstream in the service workflow chain. In this way, the interface to each modeling component becomes uniform and the entire end-to-end workflow can be run using any existing or custom workflow processing engine. The architecture lets users extend workflows as new modeling components become available, chain together the components using any existing or custom workflow processing engine, and distribute them across any Internet-accessible Web Service endpoints. The workflow components can be hosted on any Internet-accessible machine

  6. Diurnal variations of the ionospheric electron density height profiles over Irkutsk: Comparison of the incoherent scatter radar measurements, GSM TIP simulations and IRI predictions

    Science.gov (United States)

    Zherebtsov, G. A.; Ratovsky, K. G.; Klimenko, M. V.; Klimenko, V. V.; Medvedev, A. V.; Alsatkin, S. S.; Oinats, A. V.; Lukianova, R. Yu.

    2017-07-01

    The long-duration continuous Irkutsk incoherent scatter radar (ISR) measurements allowed us to obtain the monthly averaged height-diurnal variations of the electron density in the 180-600 km altitudinal range for 4 four seasons (winter, spring, summer, autumn) and for two solar activity levels (low and moderate). Considering these electron density variations as ;quiet ionosphere patterns; we compared them with the Global Self-consistent Model of the Thermosphere, Ionosphere and Protonosphere (GSM TIP) simulations and the International Reference Ionosphere (IRI) predictions. It was found that some observational features revealed from the ISR measurements are reproduced nicely by both the theoretical and empirical models, and some features agree better with the GSM TIP than with IRI. None of the models is able to reproduce a detailed multi-peak behavior of the electron density observed by ISR at ∼300 km and above for the spring and autumn under low solar activity, while for the spring the GSM TIP tends to reproduce the morning and daytime peaks at the same local times as they are seen from the ISR observations.

  7. A field study of the accuracy and reliability of a biometric iris recognition system.

    Science.gov (United States)

    Latman, Neal S; Herb, Emily

    2013-06-01

    The iris of the eye appears to satisfy the criteria for a good anatomical characteristic for use in a biometric system. The purpose of this study was to evaluate a biometric iris recognition system: Mobile-Eyes™. The enrollment, verification, and identification applications were evaluated in a field study for accuracy and reliability using both irises of 277 subjects. Independent variables included a wide range of subject demographics, ambient light, and ambient temperature. A sub-set of 35 subjects had alcohol-induced nystagmus. There were 2710 identification and verification attempts, which resulted in 1,501,340 and 5540 iris comparisons respectively. In this study, the system successfully enrolled all subjects on the first attempt. All 277 subjects were successfully verified and identified on the first day of enrollment. None of the current or prior eye conditions prevented enrollment, verification, or identification. All 35 subjects with alcohol-induced nystagmus were successfully verified and identified. There were no false verifications or false identifications. Two conditions were identified that potentially could circumvent the use of iris recognitions systems in general. The Mobile-Eyes™ iris recognition system exhibited accurate and reliable enrollment, verification, and identification applications in this study. It may have special applications in subjects with nystagmus. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Reliability of automatic biometric iris recognition after phacoemulsification or drug-induced pupil dilation.

    Science.gov (United States)

    Seyeddain, Orang; Kraker, Hannes; Redlberger, Andreas; Dexl, Alois K; Grabner, Günther; Emesz, Martin

    2014-01-01

    To investigate the reliability of a biometric iris recognition system for personal authentication after cataract surgery or iatrogenic pupil dilation. This was a prospective, nonrandomized, single-center, cohort study for evaluating the performance of an iris recognition system 2-24 hours after phacoemulsification and intraocular lens implantation (group 1) and before and after iatrogenic pupil dilation (group 2). Of the 173 eyes that could be enrolled before cataract surgery, 164 (94.8%) were easily recognized postoperatively, whereas in 9 (5.2%) this was not possible. However, these 9 eyes could be reenrolled and afterwards recognized successfully. In group 2, of a total of 184 eyes that were enrolled in miosis, a total of 22 (11.9%) could not be recognized in mydriasis and therefore needed reenrollment. No single case of false-positive acceptance occurred in either group. The results of this trial indicate that standard cataract surgery seems not to be a limiting factor for iris recognition in the large majority of cases. Some patients (5.2% in this study) might need "reenrollment" after cataract surgery. Iris recognition was primarily successful in eyes with medically dilated pupils in nearly 9 out of 10 eyes. No single case of false-positive acceptance occurred in either group in this trial. It seems therefore that iris recognition is a valid biometric method in the majority of cases after cataract surgery or after pupil dilation.

  9. In vitro evaluation of iris chafe protection afforded by hydrophilic surface modification of polymethylmethacrylate intraocular lenses.

    Science.gov (United States)

    Hofmeister, F M; Yalon, M S; Iida, S; Goldberg, M D

    1988-09-01

    An in vitro iris chafe test was developed to evaluate possible differences in abrasive interaction of various intraocular lens (IOL) materials with the posterior surface of the iris. The materials that were compared in initial tests with rabbit irides were high molecular weight polymethylmethacrylate (PMMA), the primary IOL material in current use, and surface-modified PMMA, which had a permanent, chemically bound, hydrophilic, polymer surface. Scanning electron microscopy, light microscopy, and examination of histological sections were used to assess tissue damage. A "window defect" type of abrasive damage was observed by light microscopy for PMMA lenses and is very similar in appearance to that seen for iris abrasion by human implants when viewed in vivo in slitlamp examinations. Results for both pigmented and albino rabbit irides indicate a reduction in abrasive insult to the external iris basement membrane and underlying pigment epithelium by the hydrophilic surface modification of PMMA. These results are consistent with our observation of a major reduction in corneal endothelium damage on contact with the hydrophilic surface-modified PMMA as compared with PMMA itself. This in vitro iris abrasion test, therefore, appears to be a useful technique for future evaluation of IOL surface properties.

  10. [Coding Causes of Death with IRIS Software. Impact in Navarre Mortality Statistic].

    Science.gov (United States)

    Floristán Floristán, Yugo; Delfrade Osinaga, Josu; Carrillo Prieto, Jesus; Aguirre Perez, Jesus; Moreno-Iribas, Conchi

    2016-08-02

    There are few studies that analyze changes in mortality statistics derived from the use of IRIS software, an automatic system for coding multiple causes of death and for the selection of the underlying cause of death, compared to manual coding. This study evaluated the impact of the use of IRIS in the Navarre mortality statistic. We proceeded to double coding 5,060 death certificates corresponding to residents in Navarra in 2014. We calculated coincidence between the two encodings for ICD10 chapters and for the list of causes of the Spanish National Statistics Institute (INE-102) and we estimated the change on mortality rates. IRIS automatically coded 90% of death certificates. The coincidence to 4 characters and in the same chapter of the CIE10 was 79.1% and 92.0%, respectively. Furthermore, coincidence with the short INE-102 list was 88.3%. Higher matches were found in death certificate of people under 65 years. In comparison with manual coding there was an increase in deaths from endocrine diseases (31%), mental disorders (19%) and disease of nervous system (9%), while a decrease of genitourinary system diseases was observed (21%). The coincidence at level of ICD10 chapters coding by IRIS in comparison to manual coding was 9 out of 10 deaths, similar to what is observed in other studies. The implementation of IRIS has led to increased of endocrine diseases, especially diabetes and hyperlipidaemia, and mental disorders, especially dementias.

  11. Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Gustavo Bonfadini

    2015-10-01

    Full Text Available ABSTRACTPurpose:To investigate the relationship between quantitative iris parameters and the presence of keratoconus.Methods:Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT. To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC curves.Results:Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC, which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used.Conclusions:In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.

  12. Lack of Radiation Maculopathy After Palladium-103 Plaque Radiotherapy for Iris Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Yacoub A. [New York Eye Cancer Center, New York Eye and Ear Infirmary, and New York University School of Medicine, New York, NY (United States); Finger, Paul T., E-mail: pfinger@eyecancer.com [New York Eye Cancer Center, New York Eye and Ear Infirmary, and New York University School of Medicine, New York, NY (United States)

    2012-07-15

    Purpose: To report on the risk of radiation maculopathy for iris and iridociliary melanomas treated by {sup 103}Pd plaque radiotherapy. Methods and Materials: This is a retrospective clinical case series of 30 eyes in 30 patients with melanomas limited to the iris or invading the ciliary body. The main outcome measures included demographic information, laterality, tumor size, location, visual acuity, radiation dose, local control, retinal evaluation, and duration of follow-up. Results: Thirty patients were followed for a median 36 months (range, 12-90 months). Sixteen of 30 tumors (53%) were pure iris melanomas, and 14 (47%) were primary iris melanomas extending into the ciliary body. Radiation dosimetry showed that the median tumor apex dose was 85 Gy (range, 75-100 Gy), lens dose 43.5 Gy (range, 17.8-60 Gy), fovea dose 1.8 Gy (range, 1.3-5 Gy), and central optic disc dose 1.7 Gy (range, 1.3-4.7 Gy). Cataracts developed in 20 of the 28 phakic eyes (71.4%). No patient in this series developed radiation maculopathy or radiation optic neuropathy. Last best-corrected visual acuity was {>=}20/25 in 28 patients (93%) at a median 36 months' follow-up. Conclusion: Though visual acuities were transiently affected by radiation cataract, no radiation maculopathy or optic neuropathy has been noted after {sup 103}Pd treatment of iris and iridociliary melanomas.

  13. Simulation of the temperature increase in porcine cadaver iris during direct illumination by femtosecond laser pulses

    Science.gov (United States)

    Sun, Hui; Kurtz, Ronald M.; Juhasz, Tibor

    2012-03-01

    As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. The temperature increase induced by a 60 kHz iFS Advanced Femtosecond Laser (AMO Inc., Santa Ana, CA) in porcine cadaver iris was simulated using COMSOL (Comsol Inc., Burlington, MA) finite element software. Temperature increases up to 2.45 °C (corresponding to 2 μJ laser pulse energy and 24 second illumination) were observed in the porcine cadaver iris from the simulation with little variation in temperature profiles compared with specimens for the same laser energy illumination in experiment. : The commercial iFS Advanced Femtosecond Laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 1.23 °C temperature increase and, therefore, does not present a safety hazard to the iris.

  14. Coastal and Inland Aquatic Data Products for the Hyperspectral Infrared Imager (HyspIRI)

    Science.gov (United States)

    Abelev, Andrei; Babin, Marcel; Bachmann, Charles; Bell, Thomas; Brando, Vittorio; Byrd, Kristin; Dekker , Arnold; Devred, Emmanuel; Forget, Marie-Helene; Goodman, James; hide

    2015-01-01

    The HyspIRI Aquatic Studies Group (HASG) has developed a conceptual list of data products for the HyspIRI mission to support aquatic remote sensing of coastal and inland waters. These data products were based on mission capabilities, characteristics, and expected performance. The topic of coastal and inland water remote sensing is very broad. Thus, this report focuses on aquatic data products to keep the scope of this document manageable. The HyspIRI mission requirements already include the global production of surface reflectance and temperature. Atmospheric correction and surface temperature algorithms, which are critical to aquatic remote sensing, are covered in other mission documents. Hence, these algorithms and their products were not evaluated in this report. In addition, terrestrial products (e.g., land use land cover, dune vegetation, and beach replenishment) were not considered. It is recognized that coastal studies are inherently interdisciplinary across aquatic and terrestrial disciplines. However, products supporting the latter are expected to already be evaluated by other components of the mission. The coastal and inland water data products that were identified by the HASG, covered six major environmental and ecological areas for scientific research and applications: wetlands, shoreline processes, the water surface, the water column, bathymetry and benthic cover types. Accordingly, each candidate product was evaluated for feasibility based on the HyspIRI mission characteristics and whether it was unique and relevant to the HyspIRI science objectives.

  15. Optical quality and vision with iris-coloring soft contact lenses.

    Science.gov (United States)

    Ortiz, Carolina; Jiménez, Raimundo

    2014-05-01

    To study the influence of iris-coloring soft contact lenses, designed for changing apparent iris color, on optical quality and vision. Eighty subjects were included in this study. All participants were classified as emmetropic, with monocular best-corrected visual acuity of 20/20 or better. For 40 subjects, we measured the optical quality (aberrations, the Strehl ratio, and the objective scattering index) and visual performance before and after wearing the cosmetic soft contact lenses. We also measured the optical quality and visual performance for the other 40 subjects but with a different kind of lens (fantasy soft contact lenses). Iris-coloring soft contact lenses significantly increased coma-like and total higher-order aberrations and objective scattering index (p contact lenses (p = 0.047). Iris-coloring soft contact lenses deteriorate the optical quality and worsen the contrast sensitivity function. Iris-coloring soft contact lens wearers should be informed about the effects on optical quality and visual function.

  16. Iris en sayuela signo clínico nuevo asociado al síndrome tóxico del segmento anterior: a new clinical sign associated to the anterior segment toxic syndrome Iris in underskirt

    Directory of Open Access Journals (Sweden)

    Iván Hernández López

    2010-01-01

    Full Text Available OBJETIVO: Presentar un nuevo signo clínico como resultado del desprendimiento gigante del epitelio pigmentado posterior del iris en el curso de un síndrome tóxico del segmento anterior tras una cirugía de catarata. MÉTODOS: Presentamos un paciente intervenido de catarata mediante facoemulsificación con implante de lente intraocular de cámara posterior plegable, sin incidencias ni complicaciones transoperatorias. Se le realizó evaluación biomicroscópica en el posoperatorio inmediato diagnosticándosele un síndrome tóxico del segmento anterior asociado a un desprendimiento gigante del epitelio pigmentado posterior del iris. Se tomaron fotos durante la evolución del paciente para documentar este raro signo clínico. RESULTADOS: Al provocar la dilatación pupilar farmacológica nos encontramos con la retracción de todas las capas anteriores del iris, mostrando por debajo al epitelio pigmentado posterior del iris sinequiado al lente intraocular y tan extensamente desprendido que simulaba un segundo iris. No encontramos este hallazgo clínico reportado en la literatura revisada. Denominamos este signo como iris en sayuela. CONCLUSIONES: El desprendimiento del epitelio pigmentado posterior del iris constituye un hallazgo clínico que puede aparecer raramente asociado al síndrome tóxico del segmento anterior y cuando es muy extenso puede presentarse de forma insólita como el signo del iris en sayuela.OBJECTIVE: To present a new clinical sign as a result of a huge posterior pigmented epithelium detachment of the iris in the course of at toxic anterior segment syndrome after a successful cataract surgery. METHOD: A patient who had undergone a cataract surgery by phacoemulsification with posterior chamber foldable intraocular lens implantation, without any incidence or transoperative complication. He was evaluated through biomicroscopy in the immediate postoperative period where a huge posterior pigmented epithelium detachment of the iris

  17. GPS - VTEC in the American sector during a high solar activity year Observations and IRI predictions

    CERN Document Server

    Ezquer, R G; Casleo, S J; Casleo, S J; Kiorcheff, E; Meza, A; Mosert, M; Oviedo, R D V; Radicella, S M

    2002-01-01

    VTEC measurements obtained with GPS satellite signals during year 1999 are used to check the validity of IRI to predict this ionospheric variable in the American sector. Measurements obtained during June solstice and September equinox at 9 stations are considered. The considered latitude range extends from 18.4 to -64.7 and the longitude ranges from 281.3 to 297.7. The deviation between modelled and measured values was obtained. The results show that for solstice the model overestimates VTEC at nighttime, sunrise and sunset hours and underestimates VTEC for daylight hours at northern stations. For the South, IRI overestimates the VTEC for all hours of the day during solstice. Good agreement was observed for some cases during equinox. Additional studies covering more stations and conditions and using ionosonde data will be useful to complete the IRI validation.

  18. Bilateral acute depigmentation of the iris (BADI: first reported case in Brazil

    Directory of Open Access Journals (Sweden)

    Heloisa Andrade Maestrini

    2013-02-01

    Full Text Available Bilateral acute depigmentation of the iris (BADI is a recently described entity characterized by acute onset of pigment dispersion in the anterior chamber, depigmentation of the iris, and heavy pigment deposition in the anterior chamber angle. Involvement is always bilateral, simultaneous, and symmetrical. We report the case of a 61-year-old man who presented with bilateral ocular pain, red eyes, and severe photophobia. Examination revealed a dense Krukenberg spindle, heavy pigment dispersion in the anterior chamber, extensive transillumination iris defects, and a heavy pigment deposition in the trabecular meshwork bilaterally. Intraocular pressure increased to 48 mmHg in both eyes. The patient received topical steroids, maximum hypotensive treatment and oral valacyclovir. Intraocular pressure gradually decreased throughout the second and third months, and medications were gradually tapered. The time to complete resolution of pigment dispersion was 18 weeks. Visual acuity and visual fields remained normal, but the photophobia was permanent.

  19. The Hyperspectral Infrared Imager (HyspIRI) Public Health and Air Quality Applications

    Science.gov (United States)

    Luvall, Jeffrey C.; Hook, Simon J.

    2014-01-01

    The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution and life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.

  20. The Hyperspectral Infrared Imager (HyspIRI) Public Health & Air Quality Applications

    Science.gov (United States)

    Luvall, Jeffrey C.; Hook, Simon J.

    2013-01-01

    The neglected tropical diseases (NTDs), a group of chronic, debilitating, and poverty-promoting parasitic, bacterial, and some viral and fungal infections, are among the most common causes of illness of the poorest people living in developing countries. Abiotic environmental factors are important in determining the distribution of disease-causing vectors and their life-cycles. HyspIRI observations can be merged through a Land Data Assimilation System (LDAS) be used to drive spatially-explicit ecological models of NTD vectors distribution & life cycles. Assimilations will be driven by observational data LDAS and satellite-derived meteorological forcing data, parameter datasets, and assimilation observations. HyspIRI hyperspectral measurements would provide global measurements of surface mineralogy and biotic crusts important in accessing the impact of dust in human health. HyspIRI surface thermal measurements would also help identify the variability of dust sources due to surface moisture conditions and map mineralogy.