WorldWideScience

Sample records for production test 231-12

  1. 22 CFR 231.12 - Prosecution of claims.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Prosecution of claims. 231.12 Section 231.12 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ARAB REPUBLIC OF EGYPT LOAN GUARANTEES ISSUED UNDER THE EMERGENCY WARTIME SUPPLEMENTAL APPROPRIATIONS ACT OF 2003, PUBLIC LAW 108-11-STANDARD TERMS AND...

  2. Antimicrobials Products Tested or Pending Testing

    Science.gov (United States)

    The agency has completed testing of the majority of registered hospital disinfectants and tuberculocide products. The list of products can assist users in making informed choices regarding infection control in their facilities.

  3. Testing confectionary products

    International Nuclear Information System (INIS)

    Kumar, M.; Smith, I.H.

    1983-01-01

    Cream-filled cakes are tested by passing a #betta#-ray from a #betta#-particle source to a detector and checking the #betta#-particle count to indicate if the cakes have been correctly filled with cream. The presence of a cake to be tested is sensed by an optical detector and incorrectly filled cakes are removed by a plunger. (author)

  4. Fission product separations testing

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, D.A.; DePaoli, S.M. [Oak Ridge National Lab., TN (United States)

    1997-10-01

    The initial goal of this task is to adequately understand the treatment needs of the end user in treating contaminated wastewater. These needs are then incorporated into the evaluation of new treatment technologies for wastewater treatment. Pertinent information is than supplied to the end user so that they can select a preferred process to meet their waste treatment needs. New sorbent materials, ion-exchange materials, or other processes of interest to DOE`s Office of Environmental Restoration (EM-40) will be evaluated initially for the removal of {sup 90}Sr and {sup 137}Cs from groundwater and process wastewater. Laboratory studies will strive to obtain a quantitative understanding of the behavior of these new materials and to evaluate their sorption efficiency in reference to a standard benchmark treatment technique. Testing of the new materials will begin by conducting scoping tests where new treatment materials are compared with standard, commercially available materials in batch shaker tests. Experimental data for the most promising sorbents will then be fit to an equilibrium model so that nuclide sorption can be predicted for variable wastewater composition. Additional testing with actual wastewater will be conducted with two or three of the most effective treatment methods. Once batch testing of a treatment method is completed, dynamic column tests will be performed to validate the equilibrium sorption model and to obtain the defining column operating parameters for scaling up the technology.

  5. Tobacco and Nicotine Product Testing

    Science.gov (United States)

    Biener, Lois; Leischow, Scott J.; Zeller, Mitch R.

    2012-01-01

    Introduction: Tobacco product testing is a critical component of the Family Smoking Prevention and Tobacco Control Act (FSPTCA), which grants the Food and Drug Administration the authority to regulate tobacco products. The availability of methods and measures that can provide accurate data on the relative health risks across types of tobacco products, brands, and subbrands of tobacco products on the validity of any health claims associated with a product, and on how consumers perceive information on products toxicity or risks is crucial for making decisions on the product's potential impact on public health. These tools are also necessary for making assessments of the impact of new indications for medicinal products (other than cessation) but more importantly of tobacco products that may in the future be marketed as cessation tools. Objective: To identify research opportunities to develop empirically based and comprehensive methods and measures for testing tobacco and other nicotine-containing products so that the best science is available when decisions are made about products or policies. Methods: Literature was reviewed to address sections of the FSPTCA relevant to tobacco product evaluation; research questions were generated and then reviewed by a committee of research experts. Results: A research agenda was developed for tobacco product evaluation in the general areas of toxicity and health risks, abuse liability, consumer perception, and population effects. Conclusion: A cohesive, systematic, and comprehensive assessment of tobacco products is important and will require building consensus and addressing some crucial research questions. PMID:21460383

  6. Fibrin degradation products blood test

    Science.gov (United States)

    ... behind when clots dissolve in the blood. A blood test can be done to measure these products. ... Certain medicines can change blood test results. Tell your health care provider about all the medicines you take. Your provider will tell you if you need ...

  7. Natural gas production verification tests

    International Nuclear Information System (INIS)

    1992-02-01

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) in compliance with the requirements of the National Environmental Policy Act of 1969. The Department of Energy (DOE) proposes to fund, through a contract with Petroleum Consulting Services, Inc. of Canton, Ohio, the testing of the effectiveness of a non-water based hydraulic fracturing treatment to increase gas recovery from low-pressure, tight, fractured Devonian Shale formations. Although Devonian Shales are found in the Appalachian, Michigan, and Illinois Basins, testing will be done only in the dominant, historical five state area of established production. The objective of this proposed project is to assess the benefits of liquid carbon dioxide (CO 2 )/sand stimulations in the Devonian Shale. In addition, this project would evaluate the potential nondamaging (to the formation) properties of this unique fracturing treatment relative to the clogging or chocking of pores and fractures that act as gas flow paths to the wellbore in the target gas-producing zones of the formation. This liquid CO 2 /sand fracturing process is water-free and is expected to facilitate gas well cleanup, reduce the time required for post-stimulation cleanup, and result in improved production levels in a much shorter time than is currently experienced

  8. Test Marketing in New Product Development

    Science.gov (United States)

    Klompmaker, Jay E.; And Others

    1976-01-01

    Discusses the role of test marketing in new product development, based on interviews with marketing executives. Attempts to clarify when a test market should be done, what its aims should be, and how it should be used. (JG)

  9. ConocoPhillips Gas Hydrate Production Test

    Energy Technology Data Exchange (ETDEWEB)

    Schoderbek, David [ConocoPhillips Co., Houston, TX (United States); Farrell, Helen [ConocoPhillips Co., Houston, TX (United States); Howard, James [ConocoPhillips Co., Houston, TX (United States); Raterman, Kevin [ConocoPhillips Co., Houston, TX (United States); Silpngarmlert, Suntichai [ConocoPhillips Co., Houston, TX (United States); Martin, Kenneth [ConocoPhillips Co., Houston, TX (United States); Smith, Bruce [ConocoPhillips Co., Houston, TX (United States); Klein, Perry [ConocoPhillips Co., Houston, TX (United States)

    2013-06-30

    Work began on the ConocoPhillips Gas Hydrates Production Test (DOE award number DE-NT0006553) on October 1, 2008. This final report summarizes the entire project from January 1, 2011 to June 30, 2013.

  10. Radiological testing of products containing radioactivity

    International Nuclear Information System (INIS)

    Dixon, D.W.; Knight, A.

    1980-01-01

    Consumer products containing radioactive substances are tested by NRPB to determine how much radioactive material is likely to be released from a product if it is misused or accidentally damaged. Such testing is briefly described with particular reference to ionisation chamber smoke detectors, liquid crystal display watches illuminated with gaseous tritium light sources and anti-static brushes containing polonium-210 in the form of ceramic microspheres. (U.K.)

  11. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  12. Production LHC HTS power lead test results

    International Nuclear Information System (INIS)

    Tartaglia, M.A.; Carcagno, R.H.; Feher, S.; Huang, Y.; Orris, D.F.; Pischalnikov, Y.; Rabehl, R.J.; Sylvester, C.; Zbasnik, J.

    2004-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under ''standard'' and ''extreme'' operating conditions, and the stability of performance across thermal cycles

  13. Production and test of the LHCb Muon Chamber

    CERN Multimedia

    2005-01-01

    - The Muon System of LHCb - The Multi-Wire Proportional Chambers for LHCb - Wire tension meter - Wire pitch measurement - Gas leakage test - Test with cosmic rays - Production and test summary - Gap gain uniformity - Production and test summary

  14. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  15. 46 CFR 54.05-16 - Production toughness testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Production toughness testing. 54.05-16 Section 54.05-16... Toughness Tests § 54.05-16 Production toughness testing. (a) For vessels of welded construction, production... welding procedures shall be the same as used in the fabrication of the vessel. From each test plate, one...

  16. 46 CFR 57.06-5 - Production toughness testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Production toughness testing. 57.06-5 Section 57.06-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-5 Production toughness testing. (a) In addition to the test specimens required by...

  17. 46 CFR 57.06-2 - Production test plate interval of testing.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-2 Production test plate interval of testing. (a) At least one... 46 Shipping 2 2010-10-01 2010-10-01 false Production test plate interval of testing. 57.06-2... follows: (1) When the extent of welding on a single vessel exceeds 50 lineal feet of either or both...

  18. Toxicity Tests Applied to the Biocidal Products

    OpenAIRE

    Karabay Yavaşoğlu, N.Ülkü

    2015-01-01

    Biocides are defined as chemical substances used to suppress, destroy, deter, render harmless, or exert a controlling effect on any harmful organism to human or animal health, or that cause damage to natural or manufactured materials. Biocidal products (BPs) containing biocides are disinfectants, products related to human and veterinary hygiene, products used for pests such as insects, rodents etc., repellents and industrial chemicals like anti-fouling paints for ship and material preservativ...

  19. Relevance of microbial finished product testing in food safety management

    NARCIS (Netherlands)

    Zwietering, M.H.; Jacxsens, L.; Membre, J.M.; Nauta, M.; Peterz, M.

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food.

  20. 75 FR 28335 - Testing and Labeling Pertaining to Product Certification

    Science.gov (United States)

    2010-05-20

    ... Product Certification; Proposed Rule #0;#0;Federal Register / Vol. 75, No. 97 / Thursday, May 20, 2010.... CPSC-2010-0038] RIN 3041-AC71 Testing and Labeling Pertaining to Product Certification AGENCY: Consumer... also address labeling of consumer products to show that the product complies with certification...

  1. 76 FR 69481 - Testing and Labeling Pertaining to Product Certification

    Science.gov (United States)

    2011-11-08

    ... 1107 Testing and Labeling Pertaining to Product Certification; Final Rule #0;#0;Federal Register / Vol... Pertaining to Product Certification AGENCY: Consumer Product Safety Commission. ACTION: Final rule. SUMMARY... that the product complies with the certification requirements under section 14(a) of the Consumer...

  2. Relevance of microbial finished product testing in food safety management

    DEFF Research Database (Denmark)

    Zwietering, Marcel H.; Jacxsens, Liesbeth; Membré, Jeanne Marie

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food......-active way by implementing an effective food safety management system. For verification activities in a food safety management system, finished product testing may however be useful. For three cases studies; canned food, chocolate and cooked ham, the relevance of testing both of finished products....... If a hazardous organism is found it means something, but absence in a limited number of samples is no guarantee of safety of a whole production batch. Finished product testing is often too little and too late. Therefore most attention should be focussed on management and control of the hazards in a more pro...

  3. Major advances in testing of dairy products: milk component and dairy product attribute testing.

    Science.gov (United States)

    Barbano, D M; Lynch, J M

    2006-04-01

    Milk component analysis is relatively unusual in the field of quantitative analytical chemistry because an analytical test result determines the allocation of very large amounts of money between buyers and sellers of milk. Therefore, there is high incentive to develop and refine these methods to achieve a level of analytical performance rarely demanded of most methods or laboratory staff working in analytical chemistry. In the last 25 yr, well-defined statistical methods to characterize and validate analytical method performance combined with significant improvements in both the chemical and instrumental methods have allowed achievement of improved analytical performance for payment testing. A shift from marketing commodity dairy products to the development, manufacture, and marketing of value added dairy foods for specific market segments has created a need for instrumental and sensory approaches and quantitative data to support product development and marketing. Bringing together sensory data from quantitative descriptive analysis and analytical data from gas chromatography olfactometry for identification of odor-active compounds in complex natural dairy foods has enabled the sensory scientist and analytical chemist to work together to improve the consistency and quality of dairy food flavors.

  4. The behavior of fission products during nuclear rocket reactor tests

    International Nuclear Information System (INIS)

    Bokor, P.C.; Kirk, W.L.; Bohl, R.J.

    1991-01-01

    Fission product release from nuclear rocket propulsion reactor fuel is an important consideration for nuclear rocket development and application. Fission product data from the last six reactors of the Rover program are collected in this paper to provide as basis for addressing development and testing issues. Fission product loss from the fuel will depend on fuel composition and reactor design and operating parameters. During ground testing, fission products can be contained downstream of the reactor. The last Rover reactor tested, the Nuclear Furnance, was mated to an effluent clean-up system that was effective in preventing the discharge of fission products into the atmosphere

  5. Testing Software Development Project Productivity Model

    Science.gov (United States)

    Lipkin, Ilya

    Software development is an increasingly influential factor in today's business environment, and a major issue affecting software development is how an organization estimates projects. If the organization underestimates cost, schedule, and quality requirements, the end results will not meet customer needs. On the other hand, if the organization overestimates these criteria, resources that could have been used more profitably will be wasted. There is no accurate model or measure available that can guide an organization in a quest for software development, with existing estimation models often underestimating software development efforts as much as 500 to 600 percent. To address this issue, existing models usually are calibrated using local data with a small sample size, with resulting estimates not offering improved cost analysis. This study presents a conceptual model for accurately estimating software development, based on an extensive literature review and theoretical analysis based on Sociotechnical Systems (STS) theory. The conceptual model serves as a solution to bridge organizational and technological factors and is validated using an empirical dataset provided by the DoD. Practical implications of this study allow for practitioners to concentrate on specific constructs of interest that provide the best value for the least amount of time. This study outlines key contributing constructs that are unique for Software Size E-SLOC, Man-hours Spent, and Quality of the Product, those constructs having the largest contribution to project productivity. This study discusses customer characteristics and provides a framework for a simplified project analysis for source selection evaluation and audit task reviews for the customers and suppliers. Theoretical contributions of this study provide an initial theory-based hypothesized project productivity model that can be used as a generic overall model across several application domains such as IT, Command and Control

  6. 46 CFR 163.003-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 163.003-27 Section 163... examination. (a) General. Each ladder produced under Coast Guard approval must be tested in accordance with... for effective monitoring throughout the production schedule. (e) Visual examination. The visual...

  7. 46 CFR 160.017-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 160.017-27 Section 160... examination. (a) General. Each ladder manufactured under Coast Guard approval must be tested in accordance... for effective monitoring throughout the production schedule. (e) Visual examination. The visual...

  8. Methodological issues in testing the marginal productivity theory

    NARCIS (Netherlands)

    P.T. Gottschalk (Peter); J. Tinbergen (Jan)

    1982-01-01

    textabstractPrevious tests of the marginal productivity theory have been criticized on several grounds reviewed by the authors. One important deficiency has been the small number of factor inputs entered in the production functions. In 1978 Gottschalk suggested a method to estimate production

  9. Endurance test for IR rig for RI production assembly (test procedure)

    International Nuclear Information System (INIS)

    Chung, Heung June; Ryu, Jeong Soo

    2000-08-01

    This test procedure details the test loop, test method, and test procedure for pressure drop, vibration and endurance test of IR Rig for RI production. From the pressure drop test, the hydraulic design requirements of the capsule are verified. HANARO limit condition is checked and the compatibility with HANARO core is verified. From flow induced vibration test vibration frequency and displacement are investigated. The wear of IR Rig is investigated through endurance test, and these data are used to evaluate the expected wear at maximum resident time of the IR Rig for RI production

  10. Optimization and Improvement of Test Processes on a Production Line

    Science.gov (United States)

    Sujová, Erika; Čierna, Helena

    2018-06-01

    The paper deals with increasing processes efficiency at a production line of cylinder heads of engines in a production company operating in the automotive industry. The goal is to achieve improvement and optimization of test processes on a production line. It analyzes options for improving capacity, availability and productivity of processes of an output test by using modern technology available on the market. We have focused on analysis of operation times before and after optimization of test processes at specific production sections. By analyzing measured results we have determined differences in time before and after improvement of the process. We have determined a coefficient of efficiency OEE and by comparing outputs we have confirmed real improvement of the process of the output test of cylinder heads.

  11. 46 CFR 160.077-23 - Production tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... fixed anchor, or (C) a tensile test machine that is capable of holding a given tension. The assembly... testing of each incoming lot of inflation chamber material before using that lot in production; (iii) Have... inspector must perform or supervise testing and inspection of at least one PFD lot in each five lots...

  12. 46 CFR 164.023-13 - Production tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... Constant Rate of Traverse tensile testing machine, capable of initial clamp separation of ten inches and a... production testing on a lot must meet the following criteria for the lot to be shipped as Coast Guard... the acceptance testing values but not less than the performance minimums. (2) Length/weight values...

  13. Dissolution test for low-activity waste product acceptance

    International Nuclear Information System (INIS)

    Ebert, W. L.

    1998-01-01

    We have measured the mean and standard deviation of the solution concentrations of B, Na, and Si attained in replicate dissolution tests conducted at temperatures of 20, 40, and 70 C, for durations of 3 and 7 days, and at glass/water mass ratios of 1:10 and 1:1. These and other tests were conducted to evaluate the adequacy of the test methods specified in privatization contracts and to develop a data base that can be used to evaluate the reliability of reported results for tests performed on the waste products. Tests were conducted with a glass that we formulated to be similar to low-activity waste products that will be produced during the remediation of Hanford tank wastes. Statistical analyses indicated that, while the mean concentrations of B, Na, and Si were affected by the values of test parameters, the standard deviation of replicate tests was not. The precision of the tests was determined primarily by uncertainties in the analysis of the test solutions. Replicate measurements of other glass properties that must be reported for Hanford low-activity waste products were measured to evaluate the possible adoption of the glass used in these tests as a standard test material for the product acceptance process

  14. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  15. Potential Errors and Test Assessment in Software Product Line Engineering

    Directory of Open Access Journals (Sweden)

    Hartmut Lackner

    2015-04-01

    Full Text Available Software product lines (SPL are a method for the development of variant-rich software systems. Compared to non-variable systems, testing SPLs is extensive due to an increasingly amount of possible products. Different approaches exist for testing SPLs, but there is less research for assessing the quality of these tests by means of error detection capability. Such test assessment is based on error injection into correct version of the system under test. However to our knowledge, potential errors in SPL engineering have never been systematically identified before. This article presents an overview over existing paradigms for specifying software product lines and the errors that can occur during the respective specification processes. For assessment of test quality, we leverage mutation testing techniques to SPL engineering and implement the identified errors as mutation operators. This allows us to run existing tests against defective products for the purpose of test assessment. From the results, we draw conclusions about the error-proneness of the surveyed SPL design paradigms and how quality of SPL tests can be improved.

  16. Collider Dipole Magnet test program from development through production

    International Nuclear Information System (INIS)

    Bailey, R.E.

    1991-01-01

    Verification of CDM performance, reliability, and magnet production processes will be accomplished during the development phase of the program. Key features of this program include thorough in process testing of magnet subassemblies, verification of the magnetic field quality, and demonstration of the CDM performance during the formal qualification program. Reliability demonstration of the CDM design includes component tests and an accelerated life test program. Prototype magnet phase will address achievement of magnet performance goals through a program of fabrications, test, analysis, redesign as required and procurement of modified parts for a second fabrication run. This process would be repeated again if necessary, and would conclude with a final design for the production magnets. Production process validation will address the effects that key production processes have upon magnet performance, using the magnets produced during the Preproduction phase

  17. Product evaluation of in situ vitrification engineering, Test 4

    International Nuclear Information System (INIS)

    Loehr, C.A.; Weidner, J.R.; Bates, S.O.

    1991-09-01

    This report is one of several that evaluates the In Situ Vitrification (ISV) Engineering-Scale Test 4 (ES-4). This document describes the chemical and physical composition, microstructure, and leaching characteristics of ES-4 product samples; these data provide insight into the expected performance of a vitrified product in an ISV buried waste application similar to that studied in ES-4

  18. Empirical testing of forecast update procedure forseasonal products

    DEFF Research Database (Denmark)

    Wong, Chee Yew; Johansen, John

    2008-01-01

    Updating of forecasts is essential for successful collaborative forecasting, especially for seasonal products. This paper discusses the results of a theoretical simulation and an empirical test of a proposed time-series forecast updating procedure. It involves a two-stage longitudinal case study...... of a toy supply chain. The theoretical simulation involves historical weekly consumer demand data for 122 toy products. The empirical test is then carried out in real-time with 291 toy products. The results show that the proposed forecast updating procedure: 1) reduced forecast errors of the annual...... provided less forecast accuracy improvement and it needed a longer time to achieve relatively acceptable forecast uncertainty....

  19. 46 CFR 163.002-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 163.002-27 Section 163... examination. Each pilot hoist manufactured under Coast Guard approval must be tested as prescribed in § 163... laboratory must also conduct the visual examination described in § 163.002-21(b). The hoist may not be sold...

  20. Automatic test comes to focal plane array production

    Science.gov (United States)

    Skaggs, Frank L.; Barton, T. D.

    1992-08-01

    To meet the needs of military and commercial markets, the infrared focal plane array industry must develop new, effective and low cost methods of fabricating and testing imaging detectors. This paper describes Texas Instruments new concepts in automated testing and cold probe technology as they apply to volume production.

  1. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility.

  2. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    International Nuclear Information System (INIS)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub

    2016-01-01

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility

  3. Production and test of the LHCf microstrip silicon system

    International Nuclear Information System (INIS)

    Bonechi, L.; Adriani, O.; Bongi, M.; Castellini, G.; D'Alessandro, R.; Faus, A.; Haguenauer, M.; Itow, Y.; Kasahara, K.; Macina, D.; Mase, T.; Masuda, K.; Matsubara, Y.; Matsumoto, H.; Menjo, H.; Mizuishi, M.; Muraki, Y.; Papini, P.; Perrot, A.L.; Ricciarini, S.

    2008-01-01

    After a preliminary installation test, successfully performed in 2007, both the detectors of the LHCf experiment are now ready to be installed at the CERN LHC accelerator for the first physics run. A beam test at SPS in September 2007 allowed to verify the performance of the apparata. Production and test of the silicon tracker developed for one of them are shortly discussed in this work.

  4. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  5. Central location test vs. home use test: Contrasting results depending on product type

    NARCIS (Netherlands)

    Boutrolle, I.; Delarue, J.; Arranz, D.; Rogeaux, M.; Köster, E.P.

    2007-01-01

    Marketing professionals and sensory scientists have several hedonic testing methods at their disposal to assess product acceptability. The central location test (CLT) which usually takes place in a standardised location under controlled conditions is more frequently used than the home use test

  6. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  7. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  8. Chemical test for mammalian feces in grain products: collaborative study.

    Science.gov (United States)

    Gerber, H R

    1989-01-01

    A collaborative study was conducted to validate the use of the AOAC alkaline phosphatase method for mammalian feces in corn meal, 44.B01-44.B06, for 7 additional products: brown rice cream, oat bran, grits, semolina, pasta flour, farina, and barley plus (a mixture of barley, oat bran, and brown rice). The proposed method determines the presence of alkaline phosphatase, an enzyme contained in mammalian feces, by using phenolphthalein diphosphate as the enzyme substrate in a test agar medium. Fecal matter is separated from the grain products by specific gravity differences in 1% test agar. As the product is distributed on liquid test agar, fecal fragments float while the grain products sink. The alkaline phosphatase cleaves phosphate radicals from phenolphthalein diphosphate, generating free phenolphthalein, which produces a pink to red-purple color around the fecal particles in the previously colorless medium. Collaborators' recovery averages ranged from 21.7 particles (72.3%) for oat bran to 25.3 particles (84.3%) for semolina at the 30 particle spike level. Overall average background was 0.4 positive reactions per food type. The collaborators reported that the method was quick, simple, and easy to use. The method has been approved interim official first action for all 7 grain products.

  9. Testing controlled productive knowledge of adverb-verb collocations ...

    African Journals Online (AJOL)

    A controlled productive test of adverb-verb collocations ..... The third approach to studying collocations, corpus analysis, ..... The collocation web model is thought to match Nation's (2001) psychological .... Theory, analysis, and applications. .... Canadian Modern ... Focus on vocabulary: Mastering the Academic Word List.

  10. Design and Testing of Subsystems for Mo-99 Production

    Energy Technology Data Exchange (ETDEWEB)

    Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Bailey, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-01

    Argonne National Laboratory, in cooperation with Los Alamos National Laboratory, is developing technology with NorthStar Medical Technologies to produce 99Mo from the γ,n reaction on a 100Mo target in an electron accelerator. During production runs and thermal testing of the helium-cooled target, it became obvious that a production-scale beam-line configuration would need a collimator to protect the target from accidental beam misplacement or a beam-profile change. A prototype high-power collimator and beam stop were designed and fabricated. Testing indicated that they will be able to operate at full power in the production-scale accelerator.

  11. L2 Writing in Test and Non-test Situations: Process and Product

    Directory of Open Access Journals (Sweden)

    Baraa Khuder

    2015-02-01

    Full Text Available Test writers sometimes complain they cannot perform to their true abilities because of time constraints. We therefore examined differences in terms of process and product between texts produced under test and non-test conditions. Ten L2 postgraduates wrote two argumentative essays, one under test conditions, with only forty minutes being allowed and without recourse to resources, and one under non-test conditions, with unlimited time as well as access to the Internet. Keystroke logging, screen capture software, and stimulated recall protocols were used, participants explaining and commenting on their writing processes. Sixteen writing process types were identified. Higher proportions of the processes of translation and surface revision were recorded in the test situation, while meaningful revision and evaluation were both higher in the non-test situation. There was a statistically significant difference between time allocation for different processes at different stages. Experienced teachers awarded the non-test texts a mean score of almost one point (0.8 higher. A correlational analysis examining the relationship between writing process and product quality showed that while the distribution of writing processes can have an impact on text quality in the test situation, it had no effect on the product in the non-test situation.

  12. New filterability and compressibility test cell design for nuclear products

    Energy Technology Data Exchange (ETDEWEB)

    Féraud, J.P. [CEA Marcoule, DTEC/SGCS/LGCI, BP 17171, 30207 Bagnols-sur-Cèze (France); Bourcier, D., E-mail: damien.bourcier@cea.fr [CEA Marcoule, DTEC/SGCS/LGCI, BP 17171, 30207 Bagnols-sur-Cèze (France); Ode, D. [CEA Marcoule, DTEC/SGCS/LGCI, BP 17171, 30207 Bagnols-sur-Cèze (France); Puel, F. [Université Lyon 1, Villeurbanne (France); CNRS, UMR5007, Laboratoire d‘Automatique et de Génie des Procédés (LAGEP), CPE-Lyon, 43 bd du 11 Novembre 1918, 69100 Villeurbanne (France)

    2013-12-15

    Highlights: • Test easily usable without tools in a glove box. • The test minimizes the slurry volume necessary for this type of study. • The test characterizes the flow resistance in a porous medium in formation. • The test is performed at four pressure levels to determine the compressibility. • The technical design ensures reproducible flow resistance measurements. -- Abstract: Filterability and compressibility tests are often carried out at laboratory scale to obtain data required to scale up solid/liquid separation processes. Current technologies, applied with a constant pressure drop, enable specific resistance and cake formation rate measurement in accordance with a modified Darcy's law. The new test cell design described in this paper is easily usable without tools in a glove box and minimizes the slurry volume necessary for this type of study. This is an advantage for investigating toxic and hazardous products such as radioactive materials. Uranium oxalate precipitate slurries were used to test and validate this new cell. In order to reduce the test cell volume, a statistical approach was applied on 8 results obtained with cylindrical test cells of 1.8 cm and 3 cm in diameter. Wall effects can therefore be ignored despite the small filtration cell diameter, allowing tests to be performed with only about one-tenth of the slurry volume of a standard commercial cell. The significant reduction in the size of this experimental device does not alter the consistency of filtration data which may be used in the design of industrial equipment.

  13. New filterability and compressibility test cell design for nuclear products

    International Nuclear Information System (INIS)

    Féraud, J.P.; Bourcier, D.; Ode, D.; Puel, F.

    2013-01-01

    Highlights: • Test easily usable without tools in a glove box. • The test minimizes the slurry volume necessary for this type of study. • The test characterizes the flow resistance in a porous medium in formation. • The test is performed at four pressure levels to determine the compressibility. • The technical design ensures reproducible flow resistance measurements. -- Abstract: Filterability and compressibility tests are often carried out at laboratory scale to obtain data required to scale up solid/liquid separation processes. Current technologies, applied with a constant pressure drop, enable specific resistance and cake formation rate measurement in accordance with a modified Darcy's law. The new test cell design described in this paper is easily usable without tools in a glove box and minimizes the slurry volume necessary for this type of study. This is an advantage for investigating toxic and hazardous products such as radioactive materials. Uranium oxalate precipitate slurries were used to test and validate this new cell. In order to reduce the test cell volume, a statistical approach was applied on 8 results obtained with cylindrical test cells of 1.8 cm and 3 cm in diameter. Wall effects can therefore be ignored despite the small filtration cell diameter, allowing tests to be performed with only about one-tenth of the slurry volume of a standard commercial cell. The significant reduction in the size of this experimental device does not alter the consistency of filtration data which may be used in the design of industrial equipment

  14. Test marketing and consumer acceptance of irradiated meat products

    International Nuclear Information System (INIS)

    Xu Zhicheng; Feng Zhixiong; Jiang Peizhen

    2001-01-01

    This study consists of two parts: irradiation processing of cooked meat and irradiation preservation of prepackaged chilled fresh cut meats. Irradiation of prepackaged pickled meat products dipped in grains stillage at a dose 6-8 kGy eliminated common food-borne microorganisms, such as E. Coli and other microbial pathogens and extended the shelf life of the product to 10 days at 5 deg. C. Test marketing of 40,000 bags (about 10,000 kg) of the product in more than 100 supermarkets in the city of Shanghai showed no untoward problem with consumer acceptance. Irradiation of prepackaged chilled fresh cut pork at a dose 3 kGy led to inactivation of microbial pathogens and parasites with a concomitant reduction in numbers of common spoilage microorganisms and extension of shelf life of the product for 30 days at 5 deg. C. The cost benefit and marketing applications were evaluated. (author)

  15. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  16. The radiological testing of consumer products 1976-1978

    International Nuclear Information System (INIS)

    Wilkins, B.T.; Dixon, D.W.

    1979-02-01

    The National Radiological Protection Board's source testing laboratory has been operational since 1976. In the intervening period the types of consumer product which have received most attention have been ionisation chamber smoke detectors and liquid crystal digital watches containing gaseous tritium light sources; the results obtained on these two types of device are the main subject of this report. The report also traces the development of the practical appraisal of these devices by the Board and describes the part played by the test results in the evolution of national and international standards. (author)

  17. Electrical Integrity Tests during Production of the LHC Dipoles

    CERN Document Server

    de Rijk, G; Cornelis, M; Fessia, P; Miles, J; Modena, M; Molinari, G; Rinn, J; Savary, F; Vlogaert, J

    2006-01-01

    For the LHC dipoles, mandatory electrical integrity tests are performed to qualify the cold mass (CM) at four production stages: individual pole, collared coil, CM before end cover welding and final CM. A description of the measurement equipment and its recent development are presented. After passing the demands set out in the specification, the results of the tests are transmitted to CERN where they are further analyzed. The paper presents the most important results of these measurements. We also report a review of the electrical non-conformities encountered e.g. interturn shorts and quench heater failure, their diagnostic and the cures.

  18. Dissolution testing of intermediary products in uranium dioxide production by the sol-gel method

    International Nuclear Information System (INIS)

    Melichar, F.; Landspersky, H.; Urbanek, V.

    1979-01-01

    A method was developed of dissolving polyuranates and uranium dioxides in sulphuric acid and in carbonate solutions for testing intermediate products in the sol-gel process preparation of uranium dioxide. A detailed granulometric analysis of spherical particle dispersion was included as part of the tests. Two different production methods were used for the two types of studied materials. The test results show that the test method is suitable for determining temperature sensitivity of the materials to dissolution reaction. The geometrical distribution of impurities in the spherical particles can be determined from the dissolution kinetics. The method allows the determination of the effect of carbon from impurities on the process of uranium dioxide leaching and is thus applicable for testing materials prepared by the sol-gel method. (Z.M.)

  19. Transient productivity index for numerical well test simulations

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, G.; Ding, D.Y.; Ene, A. [Institut Francais du Petrole, Pau (France)] [and others

    1997-08-01

    The most difficult aspect of numerical simulation of well tests is the treatment of the Bottom Hole Flowing (BHF) Pressure. In full field simulations, this pressure is derived from the Well-block Pressure (WBP) using a numerical productivity index which accounts for the grid size and permeability, and for the well completion. This productivity index is calculated assuming a pseudo-steady state flow regime in the vicinity of the well and is therefore constant during the well production period. Such a pseudo-steady state assumption is no longer valid for the early time of a well test simulation as long as the pressure perturbation has not reached several grid-blocks around the well. This paper offers two different solutions to this problem: (1) The first one is based on the derivation of a Numerical Transient Productivity Index (NTPI) to be applied to Cartesian grids; (2) The second one is based on the use of a Corrected Transmissibility and Accumulation Term (CTAT) in the flow equation. The representation of the pressure behavior given by both solutions is far more accurate than the conventional one as shown by several validation examples which are presented in the following pages.

  20. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  1. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented.

  2. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    International Nuclear Information System (INIS)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented

  3. Endurance test on IR rig for RI production

    International Nuclear Information System (INIS)

    Chung, Heung June; Youn, Y. J.; Han, H. S.; Hong, S. B.; Cho, Y. G.; Ryu, J. S.

    2000-12-01

    This report presents the pressure drop, vibration and endurance test results for IR rig for RI production which were desigened and fabricated by KAERI. From the pressure drop test results, it is noted that the flow rate through the IR rig corresponding to the pressure drop of 200 kPa is measured to be about 3.12 kg/sec. Vibration frequency for the IR rig ranges from 13 to 17 Hz. RMS(Root Mean Square) displacement for the IR rig is less than 30 μm, and the maximum displacement is less than 110μm. These experimental results show that the design criteria of IR rig meet the HANARO limit conditions. Endurance test results show that the appreciable fretting wear for the IR rig does not occur, however tiny trace of wear between contact points is observed

  4. Chemical products toxicological tests performed on lake and river fish

    International Nuclear Information System (INIS)

    Teulon, F.; Simeon, C.

    1966-01-01

    The volume and toxical values of industrial and urban effluents are growing higher and therefore acute or chronic pollution hazard is proportionally increased. Hence it is necessary to determine the effluent components minimum lethal dose for fish (one hour or six hours according to applicable standards). The following tests are described in this report: toxicity of some chemical products, tested individually (sodium, sulphate, sodium chloride, sodium fluoride, etc...); toxicity of some metal ions (Al 3+ , Fe ++ , Fe 3+ , Pb ++ , etc...); toxicity of certain mixed compounds for various fish species (sun perch, tench, gold fish, roach, gudgeon, bleak). The test results obtained represent local values and may be used for reference and as a general basis for other investigation and calculation of the effluents data when released. (author) [fr

  5. Emissions from laboratory combustor tests of manufactured wood products

    Energy Technology Data Exchange (ETDEWEB)

    Wilkening, R.; Evans, M.; Ragland, K. [Univ. of Wisconsin, Madison, WI (United States); Baker, A. [USDA Forest Products Lab., Madison, WI (United States)

    1993-12-31

    Manufactured wood products contain wood, wood fiber, and materials added during manufacture of the product. Manufacturing residues and the used products are burned in a furnace or boiler instead of landfilling. Emissions from combustion of these products contain additional compounds from the combustion of non-wood material which have not been adequately characterized to specify the best combustion conditions, emissions control equipment, and disposal procedures. Total hydrocarbons, formaldehyde, higher aldehydes and carbon monoxide emissions from aspen flakeboard and aspen cubes were measured in a 76 mm i.d. by 1.5 m long fixed bed combustor as a function of excess oxygen, and temperature. Emissions of hydrocarbons, aldehydes and CO from flakeboard and from clean aspen were very sensitive to average combustor temperature and excess oxygen. Hydrocarbon and aldehyde emissions below 10 ppM were achieved with 5% excess oxygen and 1,200{degrees}C average temperature for aspen flakeboard and 1,100{degrees}C for clean aspen at a 0.9 s residence time. When the average temperature decreased below these levels, the emissions increased rapidly. For example, at 950{degrees}C and 5% excess oxygen the formaldehyde emissions were over 1,000 ppM. These laboratory tests reinforce the need to carefully control the temperature and excess oxygen in full-scale wood combustors.

  6. Biodiesel production through hydrodynamic cavitation and performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Amit; Verma, Ashish; Kachhwaha, S.S.; Maji, S. [Department of Mechanical Engineering, Delhi College of Engineering, Bawana Road, Delhi 110042 (India)

    2010-03-15

    This paper presents the details of development of a biodiesel production test rig based on hydrodynamic cavitation followed by results of experimental investigation carried out on a four cylinder, direct injection water cooled diesel engine operating on diesel and biodiesel blend of Citrullus colocyntis (Thumba) oil. The experiment covers a wide range of engine rpm. Results show that biodiesel of Thumba oil produced through hydrodynamic cavitation technique can be used as an alternative fuel with better performance and lower emissions compared to diesel. The most significant conclusions are that (1) Biodiesel production through hydrodynamic cavitation technique seems to be a simple, efficient, time saving, eco-friendly and industrially viable process. (2) 30% biodiesel blend of Thumba oil shows relatively higher brake power, brake thermal efficiency, reduced bsfc and smoke opacity with favourable p-{theta} diagram as compared to diesel. (author)

  7. Phased array UT (Ultrasonic Testing) used in electricity production plants

    International Nuclear Information System (INIS)

    Kodaira, Takeshi

    2012-01-01

    Phased Array-Ultrasonic testing techniques widely used for detection and quantitative determination of the lattice defects which have been formed from fatigues or stress corrosion cracking in the materials used in the electricity production plants are presented with particular focus on the accurate determination of the defects depth (sizing) and defects discrimination applicable to weld metals of austenite stainless steels and Ni base alloys. The principle of this non-destructive analysis is briefly explained, followed by point and matrix focus phased array methods developed by Mitsubishi Heavy Industries, Ltd are explained rather in detail with illustration and the evaluated results. (S. Ohno)

  8. Iodox process tests in a transuranium element production campaign

    International Nuclear Information System (INIS)

    Collins, E.D.; Benker, D.E.

    1978-01-01

    The Iodox process removes gaseous iodine from air by oxidation of organic iodides and by hydrolysis-oxidation of free iodine to the stable iodate form. An Iodox system for treatment of the 10 -4 m 3 /s dissolver off-gas (DOG) stream was installed and is used for initial removal of radioiodine, this allowing the Hopcalite-charcoal to serve as a backup system in TRU. During a recent TRU production campaign, three dissolver runs were made to test the Iodox process

  9. ACRR fission product release tests: ST-1 and ST-2

    International Nuclear Information System (INIS)

    Allen, M.D.; Stockman, H.W.; Reil, K.O.; Grimley, A.J.; Camp, W.J.

    1988-01-01

    Two experiments (ST-1 and ST-2) have been performed in the Annular Core Research Reactor (ACRR) at Sandia National Laboratories (SNLA) to obtain time-resolved data on the release of fission products from irradiated fuels under light water reactor (LWR) severe accident conditions. Both experiments were conducted in a highly reducing environment at maximum fuel temperatures of greater than 2400 K. These experiments were designed specifically to investigate the effect of increased total pressure on fission product release; ST-1 was performed at approximately 0.16 MPa and ST-2 was run at 1.9 MPa, whereas other parameters were matched as closely as possible. Release rate data were measured for Cs, I, Ba, Sr, Eu, Te, and U. The release rates were higher than predicted by existing codes for Ba, Sr, Eu, and U. Te release was very low, but Te did not appear to be sequestered by the zircaloy cladding; it was evenly distributed in the fuel. In addition, in posttest analysis a unique fuel morphology (fuel swelling) was observed which may have enhanced fission product release, especially in the high pressure test (ST-2). These data are compared with analytical results from the CORSOR correlation and the VICTORIA computer model

  10. Improving Quality of Seal Leak Test Product using Six Sigma

    Science.gov (United States)

    Luthfi Malik, Abdullah; Akbar, Muhammad; Irianto, Dradjad

    2016-02-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure.

  11. Improving Quality of Seal Leak Test Product using Six Sigma

    International Nuclear Information System (INIS)

    Malik, Abdullah Luthfi; Akbar, Muhammad; Irianto, Dradjad

    2016-01-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure. (paper)

  12. 30 CFR 250.1151 - How often must I conduct well production tests?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How often must I conduct well production tests... Requirements Well Tests and Surveys § 250.1151 How often must I conduct well production tests? (a) You must conduct well production tests as shown in the following table: You must conduct: And you must submit to...

  13. A/T test system for production line; Seisan line yo A/T test system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-10

    This paper introduces an A/T test system for production line made by Meidensha, Inc. Rates and technology of mounting auto-transmissions (A/T) in recent automobiles are improving year after year. A/T production line testers were fabricated and supplied, including those for European countries. This system has the following features: the system employs low inertia AC motor, and is capable of performing tests in close conditions to actual cars; an insulated gate bipolar transistor (IGBT) inverter was employed to achieve control accuracy improvement and noise reduction; high-velocity transient measurement is possible by using a computer system based on the WindowsNT; a solenoid current slant control was employed to respond to electronically controlled A/T; and noise and vibration shift feeling instrumentation can also be used on option. Number of supply is four sets of front engine/front wheel drive (FF) car A/T testers for overseas countries, and two sets of FF A/T tests for use in Japan. (NEDO)

  14. Fabrication and testing history prototypes and production units

    Energy Technology Data Exchange (ETDEWEB)

    1954-09-01

    From April, 1951 to Aug, 1954, New York Shipbuilding Corp. carried out a subcontract with E.I. du Pont de Nemours & Company that was without parallel in the shipyard`s history. The work, designated the NYX Project for reasons of security, was vital to the operations of the Savannah River Plant, Aiken, S.C., which was then being designed and constructed by du Pont for the Atomic Energy Commission. It consisted of three broad parts: developmental and experimental work; fabrication and testing of a prototype unit; fabrication of production units. Five production units were ultimately built, one of them converted from the prototype. All were fabricated from stainless steel, and involved welding techniques, control of thermal distortion and tolerances never previously attempted on assemblies of comparable size. Du Pont`s technical experience and the background of New York Ship in heavy construction, particularly in the fabrication of naval gun turrets, were combined from the outset to resolve the difficult fabrication problems that occurred almost daily. Representatives of both companies worked together as a team in the shops and at supervisory levels to an unprecedented extent. The report is intended primarily to summarize New York Ship`s part in the project, but also includes some of du Pont`s activities since the work of the two organizations was so interrelated. Because of the scope of the program, it will not always be possible to provide detailed information, but rather to record what happened in general terms. Where the reader desires more specific data, he should refer to original plans and records, including various reports compiled during the course of the project.

  15. Quantitative concept tests of organic premium meat products

    OpenAIRE

    Chrysochou , Polymeros; Krystallis Krontalis, Athanasios

    2015-01-01

    This report is part of WP6 of the SUMMER project. The aim is to investigate how consumers perceive organic premium products and if they are willing to pay a price premium for these products. We conducted an experiment with 426 Danish consumers, in which we manipulate production method (organic vs. conventional), premium production (premium vs. non-premium) and extrinsic quality (high vs. low) across three meat products (pork, beef and chicken). Our findings show that consumers perceive organi...

  16. Test elements of direct sums and free products of free Lie algebras

    Indian Academy of Sciences (India)

    Abstract. We give a characterization of test elements of a direct sum of free Lie algebras in terms of test elements of the factors. In addition, we construct certain types of test elements and we prove that in a free product of free Lie algebras, product of the homogeneous test elements of the factors is also a test element.

  17. Test elements of direct sums and free products of free Lie algebras

    Indian Academy of Sciences (India)

    We give a characterization of test elements of a direct sum of free Lie algebras in terms of test elements of the factors. In addition, we construct certain types of test elements and we prove that in a free product of free Lie algebras, product of the homogeneous test elements of the factors is also a test element.

  18. Testing plutonium fuel assembly production for fast-neutron reactors

    International Nuclear Information System (INIS)

    Nougues, B.; Benhamou, A.; Bertothy, G.; Lepetit, H.

    1975-01-01

    The main characteristics of plutonium fuel elements for fast breeder reactors justify specific test procedures and special techniques. The specific tests relating to the Pu content consist of Pu enrichment and distribution tests, determination of the O/M ratio and external contamination tests. The specific tests performed on fuel configuration are: testing of sintered pellet diameter, testing of pin welding and checking of internal assmbly [fr

  19. Chemical Characterization and Reactivity Testing of Fuel-Oxidizer Reaction Product (Test Report)

    Science.gov (United States)

    1996-01-01

    The product of incomplete reaction of monomethylhydrazine (MMH) and nitrogen tetroxide (NTO) propellants, or fuel-oxidizer reaction product (FORP), has been hypothesized as a contributory cause of an anomaly which occurred in the chamber pressure (PC) transducer tube on the Reaction Control Subsystem (RCS) aft thruster 467 on flight STS-51. A small hole was found in the titanium-alloy PC tube at the first bend below the pressure transducer. It was surmised that the hole may have been caused by heat and pressure resulting from ignition of FORP. The NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) was requested to define the chemical characteristics of FORP, characterize its reactivity, and simulate the events in a controlled environment which may have lead to the Pc-tube failure. Samples of FORP were obtained from the gas-phase reaction of MMH with NTO under laboratory conditions, the pulsed firings of RCS thrusters with modified PC tubes using varied oxidizer or fuel lead times, and the nominal RCS thruster firings at WSTF and Kaiser-Marquardt. Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), ion chromatography (IC), inductively coupled plasma (ICP) spectrometry, thermogravimetric analysis (TGA) coupled to FTIR (TGA/FTIR), and mechanical impact testing were used to qualitatively and quantitatively characterize the chemical, thermal, and ignition properties of FORP. These studies showed that the composition of FORP is variable but falls within a limited range of compositions that depends on the fuel loxidizer ratio at the time of formation, composition of the post-formation atmosphere (reducing or oxidizing), and reaction or postreaction temperature. A typical composition contains methylhydrazinium nitrate (MMHN), ammonium nitrate (AN), methylammonium nitrate (MAN), and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. The thermal decomposition

  20. Upgrade and Development of Nuclear Data Production Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-04-15

    It is necessary to improve the Pohang Neutron Facility (PNF) in order to be used as a nuclear data production facility for users in both domestic and abroad. We improved following items: (1) upgrade the electron linac, (2) collimators inside the TOF beam pipe, (3) the development and installation of an automatic sample changer, (4) the extension of the TOF beam line, and (5) the data acquisition system. We would like to establish a utilization system for users to measure the nuclear data at the PNF. To do this, we made manuals for the accelerator operation and the data acquisition system. We also made an application form to apply for users to measure the nuclear data in both domestic and abroad. The main object of the Pohang Neutron Facility is to measure the nuclear data in the neutron energy region from thermal neutron to few hundreds of eV. In addition to neutron beams produced at the PNF, photon and electron beams are produced in this facility. We thus utilize this facility for other fields, such as test facility for detectors, activation experiments, polarized neutron beam source, and so on. In addition to these, we could use this facility for training students

  1. Upgrade and development of nuclear data production test facility

    Energy Technology Data Exchange (ETDEWEB)

    Namkung, Won; Ko, I. S.; Cho, M. H.; Lee, Y. S.; Kang, H. S. [Pohang Univ. of Science and Technology, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Koh, S. K. [Univ. of Ulsan, Ulsan (Korea, Republic of); Ro, T. I. [Donga Univ., Busan (Korea, Republic of); Choi, G. U. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-04-15

    It is necessary to improve the Pohang Neutron Facility (PNF) in order to be used as a nuclear data production facility for users in both domestic and abroad. We improved following items: upgrade the electron linac, collimators inside the TOF beam pipe, the development and installation of an automatic sample changer, the extension of the TOF beam line, and the data acquisition system. We would like to establish a utilization system for users to measure the nuclear data at the PNF. To do this, we made manuals for the accelerator operation and the data acquisition system. We also made an application form to apply for users to measure the nuclear data in both domestic and abroad. The main object of the Pohang Neutron Facility is to measure the nuclear data in the neutron energy region from thermal neutron to few hundreds of eV. In addition to neutron beams produced at the PNF, photon and electron beams are produced in this facility. We thus utilize this facility for other fields, such as test facility for detectors, activation experiments, polarized neutron beam source, and so on. In addition to these, we could use this facility for training students.

  2. 76 FR 22608 - Third Party Testing for Certain Children's Products; Clothing Textiles: Revisions to Terms of...

    Science.gov (United States)

    2011-04-22

    ... Product Certifications Based on Third Party Conformity Assessment Body Testing Prior to Commission's... the product. The Commission also emphasizes that, irrespective of certification, the product in... lifting the stay of enforcement with regard to testing and certification of children's products under 16...

  3. 46 CFR 57.06-3 - Method of performing production testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Method of performing production testing. 57.06-3 Section 57.06-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-3 Method of performing production testing. (a) Except as...

  4. 46 CFR 160.176-15 - Production tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... known weight and winch, (B) a scale, winch, and fixed anchor, or (C) a tensile test machine that is... laboratory inspector tests and inspects the lot; (ii) Perform required testing of each incoming lot of... produced the components used in the lifejacket. (d) Samples. (1) Samples used in testing and inspections...

  5. 78 FR 51678 - Market Tests of Experimental Postal Products

    Science.gov (United States)

    2013-08-21

    ... Gift Cards market test on April 28, 2011.\\11\\ The market test enabled customers to purchase a gift card... United States Postal Service for Temporary Extension of Gift Cards Market Test, June 18, 2013; Docket No... authorized the market test to proceed subject to the condition that the sale of gift cards be limited to...

  6. In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan

    International Nuclear Information System (INIS)

    Weidner, J.R.; Stoots, P.R.

    1990-06-01

    In 1987, the Buried Waste Program (BWP) was established within EG ampersand G Idaho, Inc., the prime contractor at INEL. Following the Environmental Restoration guidelines of the Buried Waste Program, the In Situ Vitrification Program is participating in a Remedial Investigation/Feasibility Study (RI/FS) for permanent disposal of INEL waste, in compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). This study was requested and is being funded by the Office of Technology Development of the Idaho Operations Office of DOE (DOE-ID). As part of the RI/FS, an in situ vitrification (ISV) scoping study on the treatability of mixed low-level and mixed transuranic-contaminated waste is being performed to determine the applicability of ISV to remediation of waste at SDA. In examination of the ISV process for applicability to SDA waste, this In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan identifies the following: sampling and analysis strategy; sampling procedures; methods to conduct analyses; equipment; and procedures to ensure data quality. 8 refs., 2 tabs

  7. Wall and corner fire tests on selected wood products

    Science.gov (United States)

    H. C. Tran; M. L. Janssens

    1991-01-01

    As part of a fire growth program to develop and validate a compartment fire model, several bench-scale and full-scale tests were conducted. This paper reports the full-scale wall and corner test results of step 2 of this study. A room fire test following the ASTM proposed standard specifications was used for these full-scale tests. In step 1, we investigated the...

  8. Testing controlled productive knowledge of adverb-verb collocations ...

    African Journals Online (AJOL)

    The study also reveals that controlled productive knowledge of adverbverb collocations is less problematic. Based on these results, teaching strategies aimed at improving the use of adverb-verb collocations among EFL users are proposed. Keywords: academic writing, adverb-verb collocations, productive knowledge of ...

  9. IR Camera Report for the 7 Day Production Test

    Energy Technology Data Exchange (ETDEWEB)

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-22

    The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

  10. 76 FR 69585 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2011-11-08

    ... 1107 Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for... [CPSC Docket No. CPSC-2011-0082] Testing and Labeling Pertaining to Product Certification Regarding... to Product Certification.'' The proposed rule was intended to implement what was then known as...

  11. 77 FR 49063 - Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products

    Science.gov (United States)

    2012-08-15

    ... Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products; Proposed...-AC01 Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products... procedures for both dishwashers and conventional cooking products for the measurement of energy use in fan...

  12. 76 FR 9028 - Guidance for Industry: Potency Tests for Cellular and Gene Therapy Products; Availability

    Science.gov (United States)

    2011-02-16

    ...] Guidance for Industry: Potency Tests for Cellular and Gene Therapy Products; Availability AGENCY: Food and... Therapy Products'' dated January 2011. The guidance document provides manufacturers of cellular and gene... for Industry: Potency Tests for Cellular and Gene Therapy Products'' dated January 2011. The guidance...

  13. 40 CFR 1045.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1045.305 Section 1045.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Testing Production-line Engines § 1045.305 How must I prepare and test my production-line engines...

  14. 40 CFR 1048.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1048.305 Section 1048.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing Production-line Engines § 1048.305 How must I prepare and test my production-line engines? This...

  15. 77 FR 28673 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnace Fans

    Science.gov (United States)

    2012-05-15

    ... multipliers based on climate, consumer behavior assumptions, and product characteristics (e.g., multi-stage or... Conservation Program for Consumer Products: Test Procedures for Residential Furnace Fans; Proposed Rule #0;#0... Conservation Program for Consumer Products: Test Procedures for Residential Furnace Fans AGENCY: Office of...

  16. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-02-21

    ... Prototype testing.... Manufacturers must obtain Units with rated All tests use the Units with rated (160.151... Liferafts Prototype testing.... Existing Certificates of No cost or benefit as All tests use the Costs of... designs, overseeing prototype construction, witnessing prototype testing, and monitoring production of the...

  17. Testing painted wood : past practices at the Forest Products Laboratory and recommendations for future research

    Science.gov (United States)

    R. Sam Williams

    2009-01-01

    A brief history of paint research at the Forest Products Laboratory (FPL) in Madison, Wisconsin, sets the stage for a discussion of testing paint on wood and wood products. Tests include laboratory and outdoor tests, and I discuss them in terms of several degradation mechanisms (loss of gloss and fading, mildew growth, extractives bleed, and cracking, flaking, and...

  18. 77 FR 74559 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Science.gov (United States)

    2012-12-17

    ... Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating... Energy (DOE) is amending its test procedures for residential water heaters, direct heating equipment (DHE... necessary for residential water heaters, because the existing test procedures for those products already...

  19. Setup, tests and results for the ATLAS TileCal Read Out Driver production

    CERN Document Server

    Valero, Alberto; Castillo, V; Cuenca, C; Ferrer, A; Fullana, E; González, V; Higón, E; Munar, A; Poveda, J; Ruiz-Martínez, A; Salvachúa, B; Sanchís, E; Solans, C; Soret, J; Torres, J; Valls, J A

    2007-01-01

    In this paper we describe the performance and test results of the production of the 38 ATLAS TileCal Read Out Drivers (RODs). We first describe the basic hardware specifications and firmware functionality of the modules, the test-bench setup used for production and the test procedure to qualify the boards. We then finally show and discuss the performance results.

  20. 76 FR 2930 - Market Test of Experimental Product: “Gift Cards”

    Science.gov (United States)

    2011-01-18

    ... POSTAL SERVICE Market Test of Experimental Product: ``Gift Cards'' AGENCY: Postal Service \\TM\\. ACTION: Notice. SUMMARY: The Postal Service gives notice of a market test of an experimental product in... notice pursuant to 39 U.S.C. 3641(c)(1) that it will begin a market test of its ``Gift Cards...

  1. Testing indirect effect of consumer attitudes toward a product

    DEFF Research Database (Denmark)

    Hrubá, Renata; Sudzina, Frantisek

    2016-01-01

    a questionnaire in 2010-2011. The model is estimated using probit analysis to predict relationship between producer and consumer in decision-making when buying a new type of cheese and to examine consumer attitudes toward food origins and nutrient food security. It can be concluded that the indirect effect (e...... and on the indirect and direct effects of the perception of information through information behavior and the use of the model ordered. It is proposed that consumer levels of product familiarity of attributes affects behavior. Consumer attitudes towards agri-food products and behaviour were analyzed through...

  2. Production and quality testing of fuel briquettes made from ...

    Indian Academy of Sciences (India)

    Santhosh Ujjinappa

    2018-04-13

    Apr 13, 2018 ... Thus, this work proved that the blending of PS and TS gives better quality briquettes ... parameters such as compressed density, relaxed density, relaxation ratio ... developed for coal. The test was conducted after two weeks.

  3. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  4. Test marketing for value-added root and tuber based products in ...

    African Journals Online (AJOL)

    Test marketing for value-added root and tuber based products in Ikwuano local government area ... JE Ewuziem, C Aniedu, E Oti, VO Onyenobi ... root and tuber based products, developed at National Root Crops Research Institute, Umudike.

  5. Tests of QCD in W and Z production at Tevatron

    International Nuclear Information System (INIS)

    Abachi, S.

    1995-01-01

    We present measurements of the production cross sections times leptonic branching fractions and the transverse momentum distributions of W and Z bosons in p bar p collisions at √s = 1.8 TeV using data collected with the DO detector at the Fermilab Tevatron p bar p collider. A preliminary measurement of the W charge asymmetry is also presented

  6. Research Note Testing for a decline in secondary productivity under ...

    African Journals Online (AJOL)

    We suggest that this counterintuitive result reflects the combing out, and therefore loss, of hair in the densely vegetated site. This study failed to demonstrate a decline in secondary productivity in desertified thicket and highlights the importance of replicating such studies in space and time. African Journal of Range & Forage ...

  7. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  8. Demonstration test operation of Feed Materials Production Center Biodenitrification Facility

    International Nuclear Information System (INIS)

    Benear, A.K.; Patton, J.B.

    1987-01-01

    A fluidized-bed biological denitrification (BDN) system was used to treat high-nitrate wastewater streams from a DOE owned uranium processing plant. A two-column system was used to demonstrate BDN operation on a production scale. In a continuous 200 hour rate determination period, the BDN processed over 1.6 million gallons that contained over 4700 kilograms of nitrate and nitrite nitrogen. The BDN removed an average 97% of the incoming nitrate and nitrite. The BDN effluent was discharged to the FMPC sewage treatment plant where it caused increased levels of TOD, TSS and fecal coliforms in the STP discharge. This indicated the BDN effluent will require treatment prior to discharge to the environment. Preliminary chemical consumption rates and associated costs of operation were determined. Several modifications and additions to the system were identified as necessary for the permanent production facility. 3 refs., 11 figs., 2 tabs

  9. Tests of QCD in W and Z production at Tevatron

    International Nuclear Information System (INIS)

    Alitti, J.; Chevalier, L.; Ducros, Y.; Lebrat, J.F.; Mangeot, P.

    1995-01-01

    We present measurements of the production cross sections times leptonic branching fractions and the transverse momentum distributions of W and Z bosons in pp-bar collisions at √ s = 1.8 TeV using data collected with the DΦ detector at the Fermilab Tevatron pp-bar collider. A preliminary measurement of the W charge asymmetry is also presented. (authors). 27 refs., 9 figs., 3 tabs

  10. Facility for generating crew waste water product for ECLSS testing

    Science.gov (United States)

    Buitekant, Alan; Roberts, Barry C.

    1990-01-01

    An End-use Equipment Facility (EEF) has been constructed which is used to simulate water interfaces between the Space Station Freedom Environmental Control and Life Support Systems (ECLSS) and man systems. The EEF is used to generate waste water to be treated by ECLSS water recovery systems. The EEF will also be used to close the water recovery loop by allowing test subjects to use recovered hygiene and potable water during several phases of testing. This paper describes the design and basic operation of the EEF.

  11. Test of OZI violation in vector meson production with COMPASS

    CERN Document Server

    Bernhard, Johannes

    2011-01-01

    The COMPASS experiment at CERN SPS completed its data taking with hadron beams ($p,\\pi, K$) in the years 2008 and 2009 by collecting a large set of data using different targets (H$_{2}$, Pb, Ni, W). These data are dedicated to hadron spectroscopy, where the focus is directed to the search for exotic bound states of quarks and gluons (hybrids, glueballs). The production of such states is known to be favoured in glue-rich environments, e.g. so-called OZI-forbidden processes. The OZI rule postulates that processes with disconnected quark line diagrams are forbidden. On the one hand, the study of the degree of OZI violation in vector meson production yields the possibilty to learn more about the involved production mechanisms. On the other hand it helps to understand the nucleon's structure itself. Contrary to former experiments, the large data sample allows for detailed studies in respect to Feynman's variable $x_{F}$. We present results from the ongoing analysis on the comparison of $\\omega$ and $\\phi$ vector m...

  12. 46 CFR 160.022-4 - Approval and production tests.

    Science.gov (United States)

    2010-10-01

    ... constructed that water submerging the signal in moderately heavy seas will not cause it to become inoperative.... Ignite specimen and let it burn about 15 seconds in air. Submerge the burning signal in water in a... burn or otherwise injure the person firing it, the lot is rejected without further testing. (This...

  13. 46 CFR 160.057-4 - Approval and production tests.

    Science.gov (United States)

    2010-10-01

    ... water submerging the signal in moderately heavy seas will not cause it to become inoperable. Table 160... burning signal in water in a vertical position with head down. Obtain underwater smoke emission time by... could burn or otherwise injure the person firing it, the lot is rejected without further testing. (This...

  14. Behavior of fission products released from severely damaged fuel during the PBF severe fuel damage tests

    International Nuclear Information System (INIS)

    Osetek, D.J.; Cronenberg, A.W.; Hagrman, D.L.; Broughton, J.M.; Rest, J.

    1984-01-01

    The results of fission product release behavior during the first two Power Burst Facility Severe Fuel Damage tests are presented. Measured fission product release is compared with calculated release using temperature dependent release rate correlations and FASTGRASS analysis. The test results indicate that release from fuel of the high volatility fission products (Xe, Kr, I, Cs, and Te) is strongly influenced by parameters other than fuel temperature; namely fuel/fission product morphology, fuel and cladding oxidation state, extent of fuel liquefaction, and quench induced fuel shattering. Fission product transport from the test fuel through the sample system was strongly influenced by chemical effects. Holdup of I and Cs was affected by fission product chemistry, and transport time while Te release was primarily influenced by the extent of zircaloy oxidation. Analysis demonstrates that such integral test data can be used to confirm physical, chemical, and mechanistic models of fission product behavior for severe accident conditions

  15. Radiological protection tests for products which can lead to exposure of the public to ionizing radiation

    International Nuclear Information System (INIS)

    Hill, M.D.; Wrixon, A.D.; Wilkins, B.T.

    1976-07-01

    Testing plays an important role in deciding whether products which irradiate the general public are acceptable from a radiological protection point of view. This report discusses the role which testing should play in decision-making and develops a systematic approach to the testing of products. As an example of this approach, a proposed test programme for ionisation chamber smoke detectors is described. The use of test results as a basis for design specifications and performance requirements in the development of radiological protection standards for products is discussed. A description of the relevant standards is included. (author)

  16. Authorised allergen products for intracutaneous testing may no longer be available in Germany

    OpenAIRE

    Klimek, Ludger; Werfel, Thomas; Vogelberg, Christian; Jung, Kirsten

    2015-01-01

    Background: Beside the skin prick test, the intracutaneous test represents the most important skin test method for detecting type-1 allergies. With the incorporation of European directives into national law, test allergens used for allergy diagnosis are deemed medicinal products within the meaning of the German Medicinal Products Act (Arzneimittelgesetz) and therefore require marketing authorisation for distribution in Germany. The high costs of acquiring and maintaining these authorisations ...

  17. Testing the Altresyn Product for Oestrus Synchronization in Gilts

    Directory of Open Access Journals (Sweden)

    Liviu BOGDAN

    2017-05-01

    Full Text Available The aim of this study was to evaluate the effect of Altresyn® product (progesterone-based product as a method for synchronization of oestrus in gilts. The gilts were divided into three experimental groups. The synthetic progesterone Altrenogest was fed daily to 39 gilts at 20 mg/gilts for 18 days. In case of the first group (n = 11 gilts the treatment was performed using only Altresyn product. In group II (n=13 gilts was administered the prostaglandin hormone (Prosolvin, 0.75 mg at 24 hours after Altrenogest treatment suppression. Group III (n=15 gilts received one injections of PMSG hormone (Folligon, 500 IU/animal. Gilts were checked for oestrus twice daily and were artificially inseminated. All gilts expressed signs of oestrus between 3 and 6 days after withdrawal of Altrenogest. At the groups that were administered prostaglandin and PMSG there was a shorter duration of oestrus (group III - 26.66 hours, group II - 27.07 hours compared to group I (28.54 hours.  In this study, pregnancy rate ranged from 45.45% (group I and 93.33%(group III, while in group II the value slightly exceeded 50% (53.84%. In group I, the mean litter size was 11.6 piglets, in group II the mean value of farrowed piglets was 13.28 and 15 piglets in group III. Regarding the average number of weaned piglets in group I was 8.8, 12 in group II, while for the third group was 13.14. Altrenogest, the active ingredient in Altresyn® is effective for regulating the oestrus of gilts in commercial pig farms.

  18. Hanford Immobilized Low-Activity Waste Product Acceptance Test Plan

    International Nuclear Information System (INIS)

    Peeler, D.

    1999-01-01

    'The Hanford Site has been used to produce nuclear materials for the U.S. Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during Pu production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The DOE is proceeding with an approach to privatize the treatment and immobilization of Handord''s LAW and HLW.'

  19. Hanford Immobilized Low-Activity Waste Product Acceptance Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Peeler, D.

    1999-06-22

    'The Hanford Site has been used to produce nuclear materials for the U.S. Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during Pu production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The DOE is proceeding with an approach to privatize the treatment and immobilization of Handord''s LAW and HLW.'

  20. Background information for Van Aken on testing of NESTT product

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-11-18

    Debris from explosives testing in a shot tank that contains 4 weight percent or less of explosive is shown to be non-reactive under the specified testing protocol in the Code of Federal Regulations. This debris can then be regarded as a non-hazardous waste on the basis of reactivity, when collected and packaged in a specified manner. If it is contaminated with radioactive components (e.g. depleted uranium), it can therefore be disposed of as radioactive waste or mixed waste, as appropriate (note that debris may contain other materials that render it hazardous, such as beryllium). We also discuss potential waste generation issues in contained firing operations that are applicable to the planned new Contained Firing Facility (CFF).

  1. Fission Product Release from Molten Pool: ceramic melt tests

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Yu.B.; Lopukh, D.B.; Petchenkov, A.Yu. [AO ' NP Sintez' , St. Petersburg (RU)] [and others

    1999-07-01

    Experimental results are presented on the volatilisation of UO{sub 2{+-}}{sub x}, SrO, BaO, CeO{sub 2} from corium melts. Corium melts were generated by high frequency induction melting in a cold crucible. The surface temperature of the melts was in the range from 1753 to 3023 K. Some results of the tests are discussed and a comparison with published data is made. (author)

  2. Hybrid microcircuit technology handbook materials, processes, design, testing and production

    CERN Document Server

    Licari, James J

    1998-01-01

    The Hybrid Microcircuit Technology Handbook integrates the many diverse technologies used in the design, fabrication, assembly, and testing of hybrid segments crucial to the success of producing reliable circuits in high yields. Among these are: resistor trimming, wire bonding, die attachment, cleaning, hermetic sealing, and moisture analysis. In addition to thin films, thick films, and assembly processes, important chapters on substrate selections, handling (including electrostatic discharge), failure analysis, and documentation are included. A comprehensive chapter of design guidelines will

  3. Standard practice for ultrasonic testing of wrought products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 Purpose—This practice establishes the minimum requirements for ultrasonic examination of wrought products. Note 1—This standard was adopted to replace MIL-STD-2154, 30 Sept. 1982. This standard is intended to be used for the same applications as the document which it replaced. Users should carefully review its requirements when considering its use for new, or different applications, or both. 1.2 Application—This practice is applicable for examination of materials such as, wrought metals and wrought metal products. 1.2.1 Wrought Aluminum Alloy Products—Examination shall be in accordance with Practice B 594. 1.3 Acceptance Class—When examination is performed in accordance with this practice, engineering drawings, specifications, or other applicable documents shall indicate the acceptance criteria. Five ultrasonic acceptance classes are defined in Table 1. One or more of these classes may be used to establish the acceptance criteria or additional or alternate criteria may be specified. 1.4 Ord...

  4. Fuel bundle examination techniques for the Phebus fission product test

    International Nuclear Information System (INIS)

    Blanc, J.Y.; Clement, B.; Hardt, P. von der

    1996-01-01

    The paper develops the non-destructive examinations, with a special emphasis on transmission tomography, performed in the Phebus facility, using a linear accelerator associated with a line scan camera based on PCD components. This particular technique enabled the high level of penetration to be obtained, necessary for this high density application. Spatial resolution is not far from the theoretical limit and the density resolution is often adequate. This technique permitted: 1) to define beforehand the cuts on a precise basis, avoiding a long step-by-step choice as in previous in-pile tests; 2) to determine, at an early stage, mass balance, material relocations (in association with axial gamma spectrometry), and FP distribution, as an input into re-calculations of the bundle events. However, classical cuttings, periscopic visual examinations, macrographies, micrographies and EPMA analyses remain essential to give oxidation levels (in the less degraded zones), phase aspect and composition, to distinguish between materials of identical density, and, if possible, to estimate temperatures. Oxidation resistance of sensors (thermocouples or ultrasonic thermometers) is also traced. The EPMA gives access to the molten material chemical analyses, especially in the molten fuel blockage area. The first results show that an important part of the fuel bundle melted (which was one of the objectives of this test) and that the degradation level is close to TIMI-2 with a molten plug under a cavity surrounded by an uranium-rich crust. In lower and upper areas fuel rods are less damaged. Complementaries between these examination techniques and between international teams involved will be major advantages in the Phebus FPT0 test comprehension. 3 refs, 9 figs

  5. Feasibility test for production and separation of 103Pd

    International Nuclear Information System (INIS)

    Szuecs, Z.; Takacs, S.; Hunyadi, M.; Gacsi, Z.; Zeevaart, J.R.

    2011-01-01

    Complete text of publication follows. 103 Pd as a well-known Auger-emitter is commonly employed in brachytherapy, but the ultra-short range stopping of Auger-electrons can be more potentially exploited in applications of targeted radionuclide therapy in the future. The no-carrier-added production of 103 Pd is practically possible through charged particle induced reactions. However, separation techniques of 103 Pd from the target material (typically Rh), as well as its recovery by wet chemistry are expensive, and yields high amounts of radioactive waste. An alternative and more efficient procedure, called drydistillation method (DDM), is based on differences between the isothermal vapor pressures of the radionuclide element and the target element. In an appropriately selected temperature region the diffusion and out-gassing rates of radionuclides from the solid matrix of the target material are enhanced. Optimal irradiation parameters were determined in previous experiments at ATOMKI. Separation of 103 Pd was demonstrated at the Isotope Separator Laboratory with an evaporating-condensing system (Fig. 1). Figure 1. Evaporation-condensation system at the Isotope Separator Laboratory of ATOMKI. The irradiated Rh foil was kept above 1800?C in vacuum for several hours. The evaluation of γ-spectra of the Rh foil and the 103 Pd condensed on a low-temperature substrate (Fig. 2). The analysis resulted in a radiochemical yield of about 99.5% for 103 Pd and a radionuclidic purity of better than 99% with respect to the level of 101 Rh in the end product. Acknowledgement. The work was partly supported by the Hungarian TeT Bilateral Cooperation (OMFB- 00138/2009) and by the South African NRF (UID 68768).

  6. Multiphoton production and tests of QED at LEP-II

    International Nuclear Information System (INIS)

    Winter, M.

    2001-01-01

    Data collected by the 4 LEP collaboration from 1995 to 2000 at collision energies ranging from 130 to 208 GeV were used to measure the cross-section of the process e + e - →γγ(γ). QED predictions for this reaction were tested with a few per-cent accuracy and manifestations of physics beyond the Standard Model (SM) were investigated. Preliminary lower bounds on the cut-off parameter Λ ± , the mass of an excited electron, the string mass scale underlying low-scale Quantum Gravity and on energy scales expression various contact interactions were derived. (author)

  7. GridPix detectors: Production and beam test results

    International Nuclear Information System (INIS)

    Koppert, W.J.C.; Bakel, N. van; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; Graaf, H. van der; Hartjes, F.; Hessey, N.P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-01-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip

  8. GridPix detectors: Production and beam test results

    Science.gov (United States)

    Koppert, W. J. C.; van Bakel, N.; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; van der Graaf, H.; Hartjes, F.; Hessey, N. P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-12-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip.

  9. High-Technology Companies Often Turn to Colleges for Confidential 'Beta Tests' of New Products.

    Science.gov (United States)

    Turner, Judith Axler

    1988-01-01

    Beta testing--the process of trying a product in a real-world setting before releasing it commercially--exploits a natural interface between universities and high-technology industries. High-tech companies need confidential, real-world tests of new products, and universities are eager to get an early look at tomorrow's technology. (MLW)

  10. 40 CFR 1048.301 - When must I test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... engines? 1048.301 Section 1048.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing Production-line Engines § 1048.301 When must I test my production-line engines? (a) If you produce engines...

  11. 40 CFR 1051.301 - When must I test my production-line vehicles or engines?

    Science.gov (United States)

    2010-07-01

    ... vehicles or engines? 1051.301 Section 1051.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Testing Production-Line Vehicles and Engines § 1051.301 When must I test my production-line vehicles or engines? (a...

  12. 40 CFR 1045.301 - When must I test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... engines? 1045.301 Section 1045.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Testing Production-line Engines § 1045.301 When must I test my production-line engines? (a) If you produce...

  13. Knowledge productivity : designing and testing a method to diagnose knowledge productivity and plan for enhancement

    NARCIS (Netherlands)

    Stam, C.D.

    2007-01-01

    Our economy has changed from an industrial into a knowledge economy in which knowledge productivity has become the main challenge. The lack of appropriate techniques to reveal knowledge productivity hinders organizations to design effective policies aiming at improving knowledge-based performance.

  14. Urea-formaldehyde resins: production, application, and testing

    Science.gov (United States)

    Nuryawan, A.; Risnasari, I.; Sucipto, T.; Heri Iswanto, A.; Rosmala Dewi, R.

    2017-07-01

    Urea-formaldehyde (UF) resin, one of the most important formaldehyde resin adhesives, is a polymeric condensation product of formaldehyde with urea, and being widely used for the manufacture of wood-based composite panels, such as plywood, particleboard, and fiberboard. In spite of its benefits such as fast curing, good performance in the panels (colorless), and lower cost; formaldehyde emission (FE) originated from either UF resin itself or composite products bonded by UF resins is considered a critical drawback as it affects human health particularly in indoor environment. In order to reduce the FE, lowering formaldehyde/urea (F/U) mole ratio in the synthesis of the UF resin was done. In this study, synthesis of UF resins was carried out following the conventional alkaline-acid two-step reaction with a second addition of urea, resulting in F/U mole ratio around 1.0, namely 0.95; 1.05, and 1.15. The UF resins produced were used as binder for particleboard making. The board was manufactured in the laboratory using shaving type particle of Gmelina wood, 8% UF resin based on oven dry particle, and 1% NH4Cl (20%wt) as hardener for the resin. The target of the thickness was 10 mm and the dimension was 25 cm x 25 cm. The resulted particleboard then was evaluated the physical and the mechanical properties by Japanese Industrial Standard (JIS) A 5908 (2003). Further, the resulted particleboard also was used for the mice cage’s wall in order to mimic the real living environment. After four weeks exposure in the cages, the mice then were evaluated their mucous organs as well as their blood. The experiment results were as follows: 1) It was possible to synthesis UF resins with low F/U mole ratio; 2) However, the particleboard bonded UF resins with low F/U mole ratio showed poor properties, particularly on the thickness swelling and modulus of elasticity; 3) There was no significant differences among the mucous organs of the mice after a month exposure FE originated from

  15. 77 FR 72205 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2012-12-05

    ... testing periodically and when there has been a material change in the product's design or manufacturing... control data during product manufacture; and using manufacturing techniques with intrinsic manufacturing... sample in the production population an equal probability of being selected (75 FR at 28349 through 28350...

  16. Design, production, and testing of field effect transistors. [cryogenic MOSFETS

    Science.gov (United States)

    Sclar, N.

    1982-01-01

    Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

  17. Moving Technologies from the Test Tube to Commercial Products

    Science.gov (United States)

    Bryant, Robert G.

    2013-01-01

    Successful technologies include objects, processes, and procedures that share a common theme; they are being used to generate new products that create economic growth. The foundation is the invention, but the invention is a small part of the overall effort. The pathway to success is understanding the competition, proper planning, record keeping, integrating a supply chain, understanding actual costs, intellectual property (IP), benchmarking, and timing. Additionally, there are obstacles that include financing, what to make, buy, and sell, and the division of labor i.e. recognizing who is best at what task. Over the past two decades, NASA Langley Research Center (LaRC) has developed several commercially available technologies. The approach to commercialization of three of these inventions; Langley Research Center-Soluble Imide (LaRC-SI, Imitec Inc.), the Thin Layer Unimorph Driver (THUNDER, FACE International), and the Macrofiber Composite (MFC, Smart Material Corp.) will be described, as well as some of the lessons learned from the process. What makes these three inventions interesting is that one was created in the laboratory; another was built using the previous invention as part of its process, and the last one was created by packaging commercial-off-the-shelf (COTS) materials thereby creating a new component.

  18. Leaching characteristics of the metal waste form from the electrometallurgical treatment process: Product consistency testing

    International Nuclear Information System (INIS)

    Johnson, S. G.; Keiser, D. D.; Frank, S. M.; DiSanto, T.; Noy, M.

    1999-01-01

    Argonne National Laboratory is developing an electrometallurgical treatment for spent fuel from the experimental breeder reactor II. A product of this treatment process is a metal waste form that incorporates the stainless steel cladding hulls, zirconium from the fuel and the fission products that are noble to the process, i.e., Tc, Ru, Nb, Pd, Rh, Ag. The nominal composition of this waste form is stainless steel/15 wt% zirconium/1--4 wt% noble metal fission products/1--2 wt % U. Leaching results are presented from several tests and sample types: (1) 2 week monolithic immersion tests on actual metal waste forms produced from irradiated cladding hulls, (2) long term (>2 years) pulsed flow tests on samples containing technetium and uranium and (3) crushed sample immersion tests on cold simulated metal waste form samples. The test results will be compared and their relevance for waste form product consistency testing discussed

  19. The Phebus fission products in pile test programme

    International Nuclear Information System (INIS)

    Bussac, J.; Holtbecker, H.

    1988-01-01

    The need for quantifying the radioactive materials escaping from an LWR Nuclear Power Plant following a melt-down accident has arisen relatively late in the nuclear reactor technology development process. The TMI-2 accident in 1979 and the Chernobyl accident in 1986 have confirmed the importance of a good knowledge of phenomena which take place in a plant undergoing extreme accident conditions. After an extensive resarch effort which has involved the major nuclear countries for several years, we are now at the stage where a selective and converging attitude should be taken towards the wide range of problems underlying severe accidents. Selective, because we must understand what is important and what could be neglected. Converging, because we must arrive at a consensus at international level on the methods to treat these problems and a common understanding of the main scientific phenomena and the models to correctly represent them. After a large amount of separate effects tests and semi-integral in-pile and out-of-pile experiments, the Phebus FP project is being started as an experimental effort to quantify the relative importance of complicated processes and to give an insight into the interconnection of various mechanisms. The overall objective of this programme is to provide a qualified data base of integral in-pile experiments to validate codes dealing with FP transport in reactor core, primary cooling system and containment. This paper describes mainly the motivations and objectives of the Phebus PF programme

  20. Comparative product testing of children's restraint systems, with inclusion of side-collision tests

    Energy Technology Data Exchange (ETDEWEB)

    Goerlitz, H. [Stiftung Warentest, Berlin (Germany); Noeske, V. [DEKRA Dresden (Germany)

    2001-07-01

    Stiftung Warentest has conducted comparative product testing for Group 0.. III child car seats to evaluate accident protection, handling, comfort of the seats, and safety against faulty use. The tests that were conducted were intended to provide assessment of product quality. Owing to great reader interest, tests conducted on child car seats have become well established for a considerable number of years now. They enjoy esteemed status, for example, in our magazine test. Stiftung Warentest conducted its first tests on children's restraint system many years ago: in May of 1968. The great interest in this topic, as evidenced by widespread feedback from readers, justifies the high costs occasioned by the dynamic testing of children's restraint systems. The popularity of this topic leads to greater sales of the particular issues of the magazine test - which carries no advertising - and at least compensates for most of the added costs necessary for dynamic collision testing. It is not generally well known that Stiftung Warentest covers approximately 90% of its budget from the sales of its two magazines test and Finanztest, and of its other special publications. The annual subsidy by the German government is relatively small. The national subsidy is intended to compensate for the loss of revenue from the exclusion of advertising. (orig.)

  1. Out-of-pile demonstration test of hydrogen production system coupling with HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Nishihara, Tetsuo; Takeda, Tetsuaki; Hada, Kazuhiko; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1999-07-01

    In Japan Atomic Energy Research Institute, a hydrogen production system is being designed to produce hydrogen by means of a steam reforming process of natural gas using nuclear heat (10 MW, 905degC) supplied by the High Temperature Engineering Test Reactor (HTTR). The safety principle and criteria are also being investigated in the HTTR hydrogen production system. Prior to coupling of the steam reforming system with the HTTR, an out-of-pile demonstration test was planned to confirm safety, controllability and performance of the steam reforming system under simulated operational conditions of the HTTR hydrogen production system. The out-of-pile test facility simulates key components downstream an intermediate heat exchanger of the HTTR hydrogen production system on a scale of 1 to 30 has a hydrogen production capacity of 110 Nm{sup 3}/h using an electric heater as a reactor substitute. The test facility is under manufacturing aiming at completion in 2000 and followed by the test till 2004. In parallel to this, a hydrogen permeation test and a corrosion test of a catalyst tube of a steam reformer are being carried out to obtain data necessary for the design of the system. This report describes outline of the out-of-pile hydrogen production facility and demonstration test program for the HTTR hydrogen production system at present status. (author)

  2. Out-of-pile demonstration test of hydrogen production system coupling with HTTR

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Nishihara, Tetsuo; Takeda, Tetsuaki; Hada, Kazuhiko; Hayashi, Koji

    1999-01-01

    In Japan Atomic Energy Research Institute, a hydrogen production system is being designed to produce hydrogen by means of a steam reforming process of natural gas using nuclear heat (10 MW, 905degC) supplied by the High Temperature Engineering Test Reactor (HTTR). The safety principle and criteria are also being investigated in the HTTR hydrogen production system. Prior to coupling of the steam reforming system with the HTTR, an out-of-pile demonstration test was planned to confirm safety, controllability and performance of the steam reforming system under simulated operational conditions of the HTTR hydrogen production system. The out-of-pile test facility simulates key components downstream an intermediate heat exchanger of the HTTR hydrogen production system on a scale of 1 to 30 has a hydrogen production capacity of 110 Nm 3 /h using an electric heater as a reactor substitute. The test facility is under manufacturing aiming at completion in 2000 and followed by the test till 2004. In parallel to this, a hydrogen permeation test and a corrosion test of a catalyst tube of a steam reformer are being carried out to obtain data necessary for the design of the system. This report describes outline of the out-of-pile hydrogen production facility and demonstration test program for the HTTR hydrogen production system at present status. (author)

  3. Use of test results from the percolation leaching test (TS3) in the framework of the Construction Products Directive

    Energy Technology Data Exchange (ETDEWEB)

    Van Zomeren, A.; Dijkstra, J.J. [ECN Environment and Energy Engineering, Petten (Netherlands); Mesman, M.; Spijker, J. [National Institute for Public Health and the Environment RIVM, Bilthoven (Netherlands); Eikelboom, R. [Ministry of Infrastructure and Environment IenM, Den Haag (Netherlands)

    2013-10-15

    The enforcement of the European Construction Products Directive (and the more actual Construction Products Regulation) has led to the development of European harmonised standards for assessment of the emission of 'dangerous substances' from construction materials. According to Basic Working Requirement (BWR) number 3, the emissions from construction products to soil and groundwater should not have an unacceptable impact on the environmental quality over the life cycle of the product. In this paper the technical needs and boundary conditions of leaching tests to obtain meaningful and reliable test results are explained. Although this paper will not go into detail on 'impact assessment' and the resulting development of regulatory criteria, we will show that the technical needs and boundary conditions of a test are to some extent dependent on what type of information is needed by regulators for environmental impact assessment. This short paper focuses on explaining the principles of testing leaching behaviour of aggregates, and briefly explains the leaching of size reduced and non-size reduced particles. It provides information for the actual discussions on size reduction before leaching tests.

  4. 76 FR 56347 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Science.gov (United States)

    2011-09-13

    ... Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating... proposed to amend, where appropriate, its test procedures for residential water heaters, direct heating... notes that the test procedure and metric for residential water heaters currently address and incorporate...

  5. SSC 254 Screen-Based Word Processors: Production Tests. The Lanier Word Processor.

    Science.gov (United States)

    Moyer, Ruth A.

    Designed for use in Trident Technical College's Secretarial Lab, this series of 12 production tests focuses on the use of the Lanier Word Processor for a variety of tasks. In tests 1 and 2, students are required to type and print out letters. Tests 3 through 8 require students to reformat a text; make corrections on a letter; divide and combine…

  6. 78 FR 41609 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...

    Science.gov (United States)

    2013-07-10

    ... September 14, 1977. 42 FR 46140. Industry representatives viewed these test procedures as too complex and... Freezers'' (HRF-1- 1979). Using this industry-created test procedure, DOE revised its test procedures on... compartment of such a product to be at a level that would effectively exclude the coverage of combination wine...

  7. Testing improvements in the chocolate traceability system: Impact on product recalls and production efficiency

    DEFF Research Database (Denmark)

    Saltini, Rolando; Akkerman, Renzo

    2012-01-01

    hypothetical improvements of the traceability system within the chocolate production system and supply chain and we illustrate the resulting benefits by using a case study. Based on the case study, we quantify the influence of these improvements on production efficiency and recall size in case of a safety......The primary aim of food traceability is to increase food safety, but traceability systems can also bring other benefits to production systems and supply chains. In the literature these benefits are extensively discussed, but studies that quantify them are scarce. In this paper we propose two...... crisis by developing a simulation tool. These results are aimed to illustrate and quantify the additional benefits of traceability information, and could help food industries in deciding whether and how to improve their traceability systems....

  8. Orally inhaled drug performance testing for product development, registration, and quality control.

    Science.gov (United States)

    Lastow, Orest; Svensson, Mårten

    2014-12-01

    A DPI can be split into three different modules; device, formulation, process. These are developed in parallel, and together with the user they provide the performance of an inhalation product. During product development, these modules are evolving and changing, whereas the requirements on an inhalation product are always expressed in terms of the performance of the final commercial product. To do performance testing during development when the product is not finished presents many challenges and can be confusing and misleading. During development, the performance of the final product is typically being predicted by testing ever changing prototypes. This article describes methods and approaches to manage such development and to, during development, provide relevant predictions of the in vitro and in vivo performances of the final product.

  9. Analyses of production tests and MDT tests conducted in Mallik and Alaska methane hydrate reservoirs : what can we learn from these well tests?

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, M.; Funatsu, K.; Ouchi, H. [Japan Oil Engineering Co., Tokyo (Japan); Masuda, Y. [Tokyo Univ., Tokyo (Japan). School of Engineering; Yamamoto, K. [Japan Oil, Gas and Metals National Corp., Tokyo (Japan); Narita, H. [National Inst. of Advanced Industrial Science and Technology, Tokyo (Japan); Dallimore, S.R. [Natural Resources Canada, Ottawa, ON (Canada). Geological Survey of Canada; Collett, T.S. [United States Geological Survey, Reston, VA (United States); Hancock, S.H. [APA Petroleum Engineering Ltd., Calgary, AB (Canada)

    2008-07-01

    This paper described a series of pressure drawdown tests conducted to evaluate a modular formation dynamics tester (MDT) wireline tool. The tests were conducted at the Mallik methane hydrate (MH) reservoir as well as in MH reservoirs in Alaska over a period of several years. Production tests were also conducted to evaluate depressurization methods, and measure production and bottomhole pressure (BHP) below known MH stability pressures in order to estimate permeability and MH dissociation radius properties. The results of the tests were then history-matched using a numerical simulator. An analysis of the simulation study showed that the MDT tests were useful in estimating initial effective permeability levels in the presence of MH. However, wellbore storage erased important data used to indicate the radius of MH dissociation and effective permeability after partial MH dissociation. The study also showed that steady flow conditions must be established before obtaining solutions from history-matched production tests. Parameters accurately estimated using the MDT and production tests were outlined, and suggestions for future designs and analyses for MH reservoirs were presented. 14 refs., 7 tabs., 17 figs.

  10. New product testing and the utilization of user expertise: Evidence from the Pharmaceutical industry

    DEFF Research Database (Denmark)

    Smed, Marie; Salomo, Søren; Schultz, Carsten

    2012-01-01

    A significant and often neglected obstacle in new product development is the testing and approval process in the late stages of development. The testing process has primarily been observed as an in-house decision process, however, in many industries products undergo extensive testing before marke....... Further, with a dispersed user network a positive effect is observed on the mean to communicate directly as issues occur. The effect of virtual communication is therefore stronger than traditional face-to-face interaction patterns.......A significant and often neglected obstacle in new product development is the testing and approval process in the late stages of development. The testing process has primarily been observed as an in-house decision process, however, in many industries products undergo extensive testing before market...... the knowledge generated and shared by medical sites and Pharmaceutical producers in late stage product development. The results show, that information regarding usage patterns and product related services are more difficult to transfer between user and developer, than issues directly related to the product...

  11. Uncovering Bugs in Distributed Storage Systems during Testing (not in Production!)

    OpenAIRE

    Deligiannis, P; McCutchen, M; Thomson, P; Chen, S; Donaldson, AF; Erickson, J; Huang, C; Lal, A; Mudduluru, R; Qadeer, S; Schulte, W

    2016-01-01

    Testing distributed systems is challenging due to multiple sources of nondeterminism. Conventional testing techniques, such as unit, integration and stress testing, are ineffective in preventing serious but subtle bugs from reaching production. Formal techniques, such as TLA+, can only verify high-level specifications of systems at the level of logic-based models, and fall short of checking the actual executable code. In this paper, we present a new methodology for testing distributed systems...

  12. Electrical production testing of the D0 Silicon microstrip tracker detector modules

    Energy Technology Data Exchange (ETDEWEB)

    D0, SMT Production Testing Group; /Fermilab

    2006-03-01

    The D0 Silicon Microstrip Tracker (SMT) is the innermost system of the D0 detector in Run 2. It consists of 912 detector units, corresponding to 5 different types of assemblies, which add up to a system with 792,576 readout channels. The task entrusted to the Production Testing group was to thoroughly debug, test and grade each detector module before its installation in the tracker. This note describes the production testing sequence and the procedures by which the detector modules were electrically tested and characterized at the various stages of their assembly.

  13. The Development of Testing Methods for Characterizing Emissions and Sources of Exposures from Polyurethane Products

    Science.gov (United States)

    The relationship between onsite manufacture of spray polyurethane foam insulation (SPFI) and potential exposures is not well understood. Currently, no comprehensive standard test methods exist for characterizing and quantifying product emissions. Exposures to diisocyanate compoun...

  14. 46 CFR 154.182 - Contiguous hull structure: Production weld test.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Contiguous hull structure: Production weld test. 154.182... Equipment Hull Structure § 154.182 Contiguous hull structure: Production weld test. If a portion of the contiguous hull structure is designed for a temperature colder than −34 °C (−30 °F) and is not part of the...

  15. Software Testing and its Relationship to the Context of the Product

    Directory of Open Access Journals (Sweden)

    Giordano Soares

    2011-12-01

    Full Text Available Test equipment today have to deal with the growing complexity of the systems under test, while the schedules, budgets and team sizes are not scaled in the same relationship. In addition, the entire test plan cannot be automate and due to time and budget constraints, only a small fraction of all use cases can be covered in the manual tests. For this, the testers must be familiar with the context of the product under test, to design a test plan effective. This article describes the advantages that lead the fact that the testers know the domain of the software product, especially in relation to managing the complexity and problems of selection and prioritization of tests

  16. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Science.gov (United States)

    2010-04-01

    ... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... capsule weight variation; (2) Disintegration time; (3) Adequacy of mixing to assure uniformity and... production process, e.g., at commencement or completion of significant phases or after storage for long...

  17. Shrub biomass production following simulated herbivory: A test of the compensatory growth hypothesis

    Science.gov (United States)

    Terri B. Teaschner; Timothy E. Fulbright

    2007-01-01

    The objective of this experiment was to test the hypotheses that 1) simulated herbivory stimulates increased biomass production in spiny hackberry (Celtis pallida), but decreases biomass production in blackbrush acacia (Acacia rigidula) compared to unbrowsed plants and 2) thorn density and length increase in blackbrush acacia to a...

  18. 46 CFR 159.007-11 - Production inspections and tests: Yearly report.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Yearly report. 159.007-11 Section 159.007-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production...

  19. 75 FR 52892 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Science.gov (United States)

    2010-08-30

    ... ``Energy Conservation Program for Consumer Products Other Than Automobiles,'' including residential water... final rule revising energy conservation standards for residential water heaters, direct heating.... EERE-2009-BT-TP-0013] RIN 1904-AB95 Energy Conservation Program for Consumer Products: Test Procedures...

  20. 77 FR 3559 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...

    Science.gov (United States)

    2012-01-25

    ... Long-Time and Variable Defrost Test Method To Fully Capture Energy Use for Temperature Recovery D... product classes. 55 FR 42845 (October 24, 1990). DOE again updated the performance standards for...: (1) Compartment temperature changes; (2) modified volume calculation methods; (3) products that...

  1. Results of a pilot scale melter test to attain higher production rates

    International Nuclear Information System (INIS)

    Elliott, M.L.; Perez, J.M. Jr.; Chapman, C.C.

    1991-01-01

    A pilot-scale melter test was completed as part of the effort to enhance glass production rates. The experiment was designed to evaluate the effects of bulk glass temperature and feed oxide loading. The maximum glass production rate obtained, 86 kg/hr-m 2 , was over 200% better than the previous record for the melter used

  2. 75 FR 57555 - Energy Conservation Program for Consumer Products: Test Procedure for Residential Clothes Washers

    Science.gov (United States)

    2010-09-21

    ... technologies not covered by the current procedure; (2) more accurately reflect current consumer behavior and... Part II Department of Energy 10 CFR Part 430 Energy Conservation Program for Consumer Products... [Docket No. EERE-2010-BT-TP-0021] RIN 1904-AC08 Energy Conservation Program for Consumer Products: Test...

  3. 75 FR 57556 - Energy Conservation Program for Consumer Products: Test Procedure for Residential Clothes Washers

    Science.gov (United States)

    2010-09-21

    ... technologies not covered by the current procedure; (2) more accurately reflect current consumer behavior and... Part II Department of Energy 10 CFR Part 430 Energy Conservation Program for Consumer Products... [Docket No. EERE-2010-BT-TP-0021] RIN 1904-AC08 Energy Conservation Program for Consumer Products: Test...

  4. 78 FR 29780 - Fees for Testing, Evaluation, and Approval of Mining Products

    Science.gov (United States)

    2013-05-21

    ... Approval of Mining Products AGENCY: Mine Safety and Health Administration, Labor. ACTION: Notice. SUMMARY..., and approval of mining products; it allows MSHA to collect fees up to $2,499,000 for the testing, evaluation, and approval of certain mining equipment. MSHA is continuing to collect these fees for 2013 as...

  5. Partial sums of lagged cross-products of AR residuals and a test for white noise

    NARCIS (Netherlands)

    de Gooijer, J.G.

    2008-01-01

    Partial sums of lagged cross-products of AR residuals are defined. By studying the sample paths of these statistics, changes in residual dependence can be detected that might be missed by statistics using only the total sum of cross-products. Also, a test statistic for white noise is proposed. It is

  6. 75 FR 78809 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...

    Science.gov (United States)

    2010-12-16

    ... discusses the treatment of combination wine storage-freezer products that were the subject of a recent test... interim final rule incorporate by reference into part 430 the following industry standards: (1) ANSI/AHAM... Rule III. Discussion A. Products Covered by the Proposed Revisions B. Combination Wine Storage-Freezer...

  7. Development of post-irradiation test facility for domestic production of 99Mo

    International Nuclear Information System (INIS)

    Taguchi, Taketoshi; Yonekawa, Minoru; Kato, Yoshiaki; Kurosawa, Makoto; Nishikata, Kaori; Ishida, Takuya; Kawamata, Kazuo

    2013-01-01

    JMTR focus on the activation method. By carrying out the preliminary tests using irradiation facilities existing, and verification tests using the irradiation facility that has developed in the cutting-edge research and development strategic strengthening business, as irradiation tests towards the production of 99 Mo, we have been conducting research and development that can contribute to supply about 25% for 99 Mo demand in Japan and the stable supply of radiopharmaceutical. This report describes a summary of the status of the preliminary tests for the production of 99 Mo: Maintenance of test equipment in the facility in JMTR hot laboratory in preparation for research and development for the production of 99 Mo in JMTR and using MoO 3 pellet irradiated at Kyoto University Research Reactor Institute (KUR). (author)

  8. 46 CFR 54.20-5 - Welding qualification tests and production testing (modifies UW-26, UW-28, UW-29, UW-47, and UW-48).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Welding qualification tests and production testing... OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Fabrication by Welding § 54.20-5 Welding qualification tests and production testing (modifies UW-26, UW-28, UW-29, UW-47, and UW-48). (a...

  9. Off-Line Testing of Tribo-Systems for Sheet Metal Forming Production

    DEFF Research Database (Denmark)

    Bay, Niels; Ceron, Ermanno

    2014-01-01

    Off-line testing of new tribo-systems for sheet metal forming production is an important issue, when new, environmentally benign lubricants are to be introduced. To obtain useful results it is, however, vital to ensure similar conditions as in the production process regarding the main tribo...... leading to very high tool/workpiece interface pressure and temperature in the second re-draw. Under such conditions only the best lubricant systems work satisfactory, and the paper shows how the performance of different tribo-systems in production may be predicted by off-line testing combined...

  10. 76 FR 22030 - Third Party Testing for Certain Children's Products; Toddler Beds: Requirements for Accreditation...

    Science.gov (United States)

    2011-04-20

    ... and content of the ILAC-MRA approach and of the requirements of the ISO/IEC 17025:2005 laboratory... to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and.... The product \\1\\ was tested by a third party conformity assessment body that was ISO/IEC 17025...

  11. 76 FR 49286 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Science.gov (United States)

    2011-08-10

    ... history and content of the ILAC-MRA approach and of the requirements of the ISO/IEC 17025:2005 laboratory... be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and..., the product was tested by a third party conformity assessment body that was ISO/IEC 17025 accredited...

  12. Power Production Experience from Wave Dragon Prototype Testing in Nissum Bredning

    DEFF Research Database (Denmark)

    Frigaard, Peter; Kofoed, Jens Peter

    The first Wave Dragon prototype power production testing started May 2003 and ended temporarily primo 2005. In the mentioned period Wave Dragon was situated in a corner of Nissum Bredning with relative little amount of wave energy. Main purpose of the tests was demonstration of survivability...

  13. 76 FR 12825 - Energy Conservation Program for Consumer Products: Test Procedure for Microwave Ovens

    Science.gov (United States)

    2011-03-09

    ... Conservation Program for Consumer Products: Test Procedure for Microwave Ovens AGENCY: Office of Energy.... Department of Energy (DOE) is amending its test procedures for microwave ovens under the Energy Policy and Conservation Act (EPCA) to provide for the measurement of standby mode and off mode power use by microwave...

  14. 75 FR 42612 - Energy Conservation Program for Consumer Products: Test Procedure for Microwave Ovens

    Science.gov (United States)

    2010-07-22

    ... Conservation Program for Consumer Products: Test Procedure for Microwave Ovens AGENCY: Office of Energy... (NOPR) in which DOE proposed test procedures for microwave ovens under the Energy Policy and Conservation Act (EPCA) to measure standby mode and off mode power use by microwave ovens. To address issues...

  15. Non-parametric tests of productive efficiency with errors-in-variables

    NARCIS (Netherlands)

    Kuosmanen, T.K.; Post, T.; Scholtes, S.

    2007-01-01

    We develop a non-parametric test of productive efficiency that accounts for errors-in-variables, following the approach of Varian. [1985. Nonparametric analysis of optimizing behavior with measurement error. Journal of Econometrics 30(1/2), 445-458]. The test is based on the general Pareto-Koopmans

  16. Evaluation of farmed cod products by a trained sensory panel and consumers in different test settings

    NARCIS (Netherlands)

    Sveinsdottir, K.; Martinsdottir, E.; Thorsdottir, F.; Schelvis-Smit, A.A.M.; Kole, A.; Thorsdottir, I.

    2010-01-01

    Sensory characteristics of farmed cod exposed to low or conventional stress levels prior to slaughter were evaluated by a trained sensory panel. Consumers in two different settings, central location test (CLT) and home-use test (HUT), also tasted the products and rated them according to overall

  17. Characterization of Corrosion Products on Carbon Steel Exposed to Natural Weathering and to Accelerated Corrosion Tests

    Directory of Open Access Journals (Sweden)

    Renato Altobelli Antunes

    2014-01-01

    Full Text Available The aim of this work was to compare the corrosion products formed on carbon steel plates submitted to atmospheric corrosion in urban and industrial atmospheres with those formed after accelerated corrosion tests. The corrosion products were characterized by X-ray diffraction, Mössbauer spectroscopy, and Raman spectroscopy. The specimens were exposed to natural weathering in both atmospheres for nine months. The morphologies of the corrosion products were evaluated using scanning electron microscopy. The main product found was lepidocrocite. Goethite and magnetite were also found on the corroded specimens but in lower concentrations. The results showed that the accelerated test based on the ASTM B117 procedure presented poor correlation with the atmospheric corrosion tests whereas an alternated fog/dry cycle combined with UV radiation exposure provided better correlation.

  18. The precision and torque production of common hip adductor squeeze tests used in elite football

    DEFF Research Database (Denmark)

    Light, N; Thorborg, K

    2016-01-01

    OBJECTIVES: Decreased hip adductor strength is a known risk factor for groin injury in footballers, with clinicians testing adductor strength in various positions and using different protocols. Understanding how reliable and how much torque different adductor squeeze tests produce will facilitate...... choosing the most appropriate method for future testing. In this study, the reliability and torque production of three common adductor squeeze tests were investigated. DESIGN: Test-retest reliability and cross-sectional comparison. METHODS: Twenty elite level footballers (16-33 years) without previous...

  19. Well test: production analysis and allocation measurement; Teste de poco: analise da producao e medicao de apropriacao

    Energy Technology Data Exchange (ETDEWEB)

    Geron, Luis Carlos [Smar Equipamentos Industriais Ltda., Sertaozinho, SP (Brazil). Dept. de Engenharia Aplicacoes; Tateishi, Sergio Hideki [Smar Equipamentos Industriais Ltda, Sertaozinho, SP (Brazil). Dept. de Pesquisa e Desenvolvimento

    2008-07-01

    The well test is an instrument frequently used to evaluate the production capacity of wells and it usually has specific requirements in the flow measurement, that are not necessary in the flow measurement system for custody transfer applications. Starting with the requirement to measure the injected product in the well when it is in the recuperation phase and it also includes compliance to specific standards for allocation measurement, because these hydrocarbon products are not treated as well as that ones in the production streams. Other important issue associated to the well test is the employment of new technologies, that helps to reduce the uncertainty of measurement as digital communication between the field devices and the flow computer through an open protocol as the Foundation Field bus. Another indication of technology evolution in the flow measurement focusing a lower uncertainty is the new version of API MPMS 11.1:2004, that requires calculation with double precision floating point, as well the correction factors with 5 decimal digits. (author)

  20. The influence of socio-cultural background and product value in usability testing.

    Science.gov (United States)

    Sonderegger, Andreas; Sauer, Juergen

    2013-05-01

    This article examines the influence of socio-cultural background and product value on different outcomes of usability tests. A study was conducted in two different socio-cultural regions, Switzerland and East Germany, which differed in a number of aspects (e.g. economic power, price sensitivity and culture). Product value (high vs. low) was varied by manipulating the price of the product. Sixty-four test participants were asked to carry out five typical user tasks in the context of coffee machine usage, measuring performance, perceived usability, and emotion. The results showed that in Switzerland, high-value products were rated higher in usability than low-value products whereas in East Germany, high-value products were evaluated lower in usability. A similar interaction effect of socio-cultural background and product value was observed for user emotion. Implications are that the outcomes of usability tests do not allow for a simple transfer across cultures and that the mediating influence of perceived product value needs to be taken into consideration. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    Science.gov (United States)

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  2. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    CERN Document Server

    Bassalat, A; The ATLAS collaboration

    2014-01-01

    During the shutdown of 2013-2014, for the enhancement of the current ATLAS Pixel Detector, a fourth layer (Insertable B Layer, IBL) is being built and will be installed between the innermost layer and a new beam pipe. A new generation of readout chip has been developed, and two different sensor designs, a rather conventional planar and a 3D design, have been bump bonded to the Front Ends. Additionally, new staves and module flex circuits have been developed. A production QA test bench was therefore established to test all production staves before integration with the new beam pipe. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are being performed on the individual components during the various production steps of the IBL; namely, connectivity tests, electrical tests and signal probing on individual parts and assembled subsystems. This paper discusses the pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results fr...

  3. [An experimental proficiency test for ability to screen 104 residual pesticides in agricultural products].

    Science.gov (United States)

    Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide

    2003-10-01

    An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.

  4. Brief description of out-of-pile test facilities for study in corrosion and fission product behaviour in flowing sodium

    International Nuclear Information System (INIS)

    Iizawa, K.; Sekiguchi, N.; Atsumo, H.

    1976-01-01

    The experimental methods to perform tests for study in corrosion and fission products behaviour in flowing sodium are outlined. Flow diagrams for the activated materials and fission products behaviour test loop are given

  5. Advanced productivity forecast using petrophysical wireline data calibrated with MDT tests and numerical reservoir simulation

    Energy Technology Data Exchange (ETDEWEB)

    Andre, Carlos de [PETROBRAS, Rio de Janeiro, RJ (Brazil); Canas, Jesus A.; Low, Steven; Barreto, Wesley [Schlumberger, Houston, TX (United States)

    2004-07-01

    This paper describes an integrated and rigorous approach for viscous and middle oil reservoir productivity evaluation using petrophysical models calibrated with permeability derived from mini tests (Dual Packer) and Vertical Interference Tests (VIT) from open hole wire line testers (MDT SLB TM). It describes the process from Dual Packer Test and VIT pre-job design, evaluation via analytical and inverse simulation modeling, calibration and up scaling of petrophysical data into a numerical model, history matching of Dual Packer Tests and VIT with numerical simulation modeling. Finally, after developing a dynamic calibrated model, we perform productivity forecasts of different well configurations (vertical, horizontal and multilateral wells) for several deep offshore oil reservoirs in order to support well testing activities and future development strategies. The objective was to characterize formation static and dynamic properties early in the field development process to optimize well testing design, extended well test (EWT) and support the development strategies in deep offshore viscous oil reservoirs. This type of oil has limitations to flow naturally to surface and special lifting equipment is required for smooth optimum well testing/production. The integrated analysis gave a good overall picture of the formation, including permeability anisotropy and fluid dynamics. Subsequent analysis of different well configurations and lifting schemes allows maximizing formation productivity. The simulation and calibration results are compared to measured well test data. Results from this work shows that if the various petrophysical and fluid properties sources are integrated properly an accurate well productivity model can be achieved. If done early in the field development program, this time/knowledge gain could reduce the risk and maximize the development profitability of new blocks (value of the information). (author)

  6. Test marketing of new smokeless tobacco products in four U.S. cities.

    Science.gov (United States)

    Rogers, John D; Biener, Lois; Clark, Pamela I

    2010-01-01

    This exploratory study was designed to assess the availability, price, and point-of-purchase marketing strategies for new smokeless tobacco products in 4 test market areas. A random sample of 50 gas stations, convenience and food stores, and tobacco shops was selected in each of 4 test market areas. Pairs of observers visited each store, recorded product information, and engaged vendors in conversation about product demand. Snus was available in 64% of the stores, but availability and price differed by brand. Point-of-purchase marketing also varied by brand on a variety of dimensions and all brands appeared to be marketed primarily to smokers. Camel Snus was described by store attendants as having the highest demand and was also the most expensive of the observed products. In light of the number of test market cities and intensity of promotion at retail locations, Camel Snus was the most intensively marketed product. The results appear to reflect differences in marketing strategy by American snus manufacturers. These strategies may help to predict future marketing of snus and other tobacco products and may provide a baseline for later assessments of product acceptance.

  7. Mixture toxicity of wood preservative products in the fish embryo toxicity test.

    Science.gov (United States)

    Coors, Anja; Dobrick, Jan; Möder, Monika; Kehrer, Anja

    2012-06-01

    Wood preservative products are used globally to protect wood from fungal decay and insects. We investigated the aquatic toxicity of five commercial wood preservative products, the biocidal active substances and some formulation additives contained therein, as well as six generic binary mixtures of the active substances in the fish embryo toxicity test (FET). Median lethal concentrations (LC50) of the single substances, the mixtures, and the products were estimated from concentration-response curves and corrected for concentrations measured in the test medium. The comparison of the experimentally observed mixture toxicity with the toxicity predicted by the concept of concentration addition (CA) showed less than twofold deviation for all binary mixtures of the active substances and for three of the biocidal products. A more than 60-fold underestimation of the toxicity of the fourth product by the CA prediction was detected and could be explained fully by the toxicity of one formulation additive, which had been labeled as a hazardous substance. The reason for the 4.6-fold underestimation of toxicity of the fifth product could not be explained unambiguously. Overall, the FET was found to be a suitable screening tool to verify whether the toxicity of formulated wood preservatives can reliably be predicted by CA. Applied as a quick and simple nonanimal screening test, the FET may support approaches of applying component-based mixture toxicity predictions within the environmental risk assessment of biocidal products, which is required according to European regulations. Copyright © 2012 SETAC.

  8. Study on control characteristics for HTTR hydrogen production system with mock-up test facility

    International Nuclear Information System (INIS)

    Inaba, Yoshitomo; Ohashi, Hirofumi; Nishihara, Tetsuo; Sato, Hiroyuki; Inagaki, Yoshiyuki; Takeda, Tetsuaki; Hayashi, Koji; Takada, Shoji

    2005-01-01

    The Japan Atomic Energy Research Institute has a demonstration test plan of a hydrogen production system by steam reforming of methane coupling with the High-Temperature Engineering Test Reactor (HTTR). Prior to the coupling of a hydrogen production plant with the HTTR, simulation tests with a mock-up test facility of the HTTR hydrogen production system (HTTR-H2) is underway. The test facility is a 1/30-scale of the HTTR-H2 and simulates key components downstream from an intermediate heat exchanger of the HTTR. The main objective of the simulation tests is the establishment and demonstration of control technology, focusing on the mitigation of a thermal disturbance to the reactor by a steam generator (SG) and on the controllability of the pressure difference between the helium and process gases at the reaction tube in a steam reformer (SR). It was confirmed that the fluctuation of the outlet helium gas temperature at the SG and the pressure difference in the SR can be controlled within the allowable range for the HTTR-H2 in the case of the system controllability test for the fluctuation of chemical reaction. In addition, a dynamic simulation code for the HTTR-H2 was verified with the obtained test data

  9. Gemfibrozil and carbamazepine decrease steroid production in zebrafish testes (Danio rerio).

    Science.gov (United States)

    Fraz, Shamaila; Lee, Abigail H; Wilson, Joanna Y

    2018-05-01

    Gemfibrozil (GEM) and carbamazepine (CBZ) are two environmentally relevant pharmaceuticals and chronic exposure of fish to these compounds has decreased androgen levels and fish reproduction in laboratory studies. The main focus of this study was to examine the effects of GEM and CBZ on testicular steroid production, using zebrafish as a model species. Chronic water borne exposures of adult zebrafish to 10 μg/L of GEM and CBZ were conducted and the dosing was confirmed by chemical analysis of water as 17.5 ± 1.78 and 11.2 ± 1.08 μg/L respectively. A 67 day exposure led to reduced reproductive output and lowered whole body, plasma, and testicular 11-ketotestosterone (11-KT). Testicular production of 11-KT was examined post exposure (42 days) using ex vivo cultures to determine basal and stimulated steroid production. The goal was to ascertain the step impaired in the steroidogenic pathway by each compound. Ex vivo 11-KT production in testes from males chronically exposed to GEM and CBZ was lower than that from unexposed males. Although hCG, 25-OH cholesterol, and pregnenolone stimulation increased 11-KT production in all treatment groups over basal levels, hCG stimulated 11-KT production remained significantly less in testes from exposed males compared to controls. 25-OH cholesterol and pregnenolone stimulated 11-KT production was similar between GEM and control groups but the CBZ group had lower 11-KT production than controls with both stimulants. We therefore propose that chronic GEM and CBZ exposure can reduce production of 11-KT in testes through direct effects independent of mediation through HPG axis. The biochemical processes for steroid production appear un-impacted by GEM exposure; while CBZ exposure may influence steroidogenic enzyme expression or function. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. How to assess the mutagenic potential of cosmetic products without animal tests?

    Science.gov (United States)

    Speit, Günter

    2009-08-01

    Animal experiments (in vivo tests) currently play a key role in genotoxicity testing. Results from in vivo tests are, in many cases, decisive for the assessment of a mutagenic potential of a test compound. The Seventh Amendment to the European Cosmetics Directive will, however, ban the European marketing of cosmetic/personal care products that contain ingredients that have been tested in animal experiments. If genotoxicity testing is solely based on the currently established in vitro tests, the attrition rate for chemicals used in cosmetic products will greatly increase due to irrelevant positive in vitro test results. There is urgent need for new and/or improved in vitro genotoxicity tests and for modified test strategies. Test strategies should consider all available information on chemistry of the test substance/the chemical class (e.g. SAR, metabolic activation and dermal adsorption). Test protocols for in vitro genotoxicity tests should be sensitive and robust enough to ensure that negative results can be accepted with confidence. It should be excluded that positive in vitro test results are due to high cytotoxicity or secondary genotoxic effects which may be thresholded and/or only occur under in vitro test conditions. Consequently, further research is needed to establish the nature of thresholds in in vitro assays and to determine the potential for incorporation of mode of action data into future risk assessments. New/improved tests have to be established and validated, considering the use of (metabolically competent) primary (skin) cells, 3D skin models and cells with defined capacity for metabolic activation (e.g. genetically engineered cell lines). The sensitivity and specificity of new and improved genotoxicity tests has to be determined by testing a battery of genotoxic and non-genotoxic chemicals. New or adapted international guidelines will be needed for these tests. The establishment of such a new genotoxicity testing strategy will take time and the

  11. Top-Down and Bottom-Up Approach for Model-Based Testing of Product Lines

    Directory of Open Access Journals (Sweden)

    Stephan Weißleder

    2013-03-01

    Full Text Available Systems tend to become more and more complex. This has a direct impact on system engineering processes. Two of the most important phases in these processes are requirements engineering and quality assurance. Two significant complexity drivers located in these phases are the growing number of product variants that have to be integrated into the requirements engineering and the ever growing effort for manual test design. There are modeling techniques to deal with both complexity drivers like, e.g., feature modeling and model-based test design. Their combination, however, has been seldom the focus of investigation. In this paper, we present two approaches to combine feature modeling and model-based testing as an efficient quality assurance technique for product lines. We present the corresponding difficulties and approaches to overcome them. All explanations are supported by an example of an online shop product line.

  12. Testing knowledge of whole English collocations available for use in written production

    DEFF Research Database (Denmark)

    Revier, Robert Lee

    2014-01-01

    Testing knowledge of whole English collocations available for use in written production: Developing tests for use with intermediate and advanced Danish learners (dansk resume nedenfor) The present foreign language acquisition research derives its impetus from four assumptions regarding knowledge...... of English collocations. These are: (a) collocation knowledge can be conceptualized as an independent knowledge construct, (b) collocations are lexical items in their own right, (c) testing of collocation knowledge should also target knowledge of whole collocations, and (d) the learning burden of a whole...... the development of Danish EFL learners’ productive knowledge of whole English collocations. Five empirical studies were designed to generate information that would shed light on the reliability and validity of the CONTRIX as a measure of collocation knowledge available for use in written production. Study 1...

  13. Psychometric characteristics of single-word tests of children's speech sound production.

    Science.gov (United States)

    Flipsen, Peter; Ogiela, Diane A

    2015-04-01

    Our understanding of test construction has improved since the now-classic review by McCauley and Swisher (1984). The current review article examines the psychometric characteristics of current single-word tests of speech sound production in an attempt to determine whether our tests have improved since then. It also provides a resource that clinicians may use to help them make test selection decisions for their particular client populations. Ten tests published since 1990 were reviewed to determine whether they met the 10 criteria set out by McCauley and Swisher (1984), as well as 7 additional criteria. All of the tests reviewed met at least 3 of McCauley and Swisher's (1984) original criteria, and 9 of 10 tests met at least 5 of them. Most of the tests met some of the additional criteria as well. The state of the art for single-word tests of speech sound production in children appears to have improved in the last 30 years. There remains, however, room for improvement.

  14. Overview of the 2006-2008 JOGMEC/NRCan/Aurora Mallik Gas Hydrate Production Test Program

    Science.gov (United States)

    Yamamoto, K.; Dallimore, S. R.

    2008-12-01

    During the winters of 2007 and 2008 the Japan Oil, Gas and Metals National Corporation (JOGMEC) and Natural Resources Canada (NRCan), with Aurora Research Institute as the operator, carried out an on-shore gas hydrate production test program at the Mallik site, Mackenzie Delta, Northwest Territories, Canada. The prime objective of the program was to verify the feasibility of depressurization technique by drawing down the formation pressure across a 12m perforated gas hydrate bearing section. This project was the second full scale production test at this site following the 2002 Japex/JNOC/GSC et al Mallik research program in which seven participants organizatinos from five countries undertook a thermal test using hot water circulation Field work in 2007 was devoted to establishing a production test well, installing monitoring devices outside of casing, conducting base line geophysical studies and undertaking a short test to gain practical experience prior to longer term testing planned for 2008 . Hydrate-dissociated gas was produced to surface by depressurization achieved by lowering the fluid level with a dowhole pump. However, the operation was terminated 60 hours after the start of the pumping mainly due to sand production problems. In spite of the short period (12.5 hours of ellapsed pumping time), at least 830m3 of the gas was produced and accumulated in the borehole. Sand screens were installed across the perforated interval at the bottom hole for the 2008 program to overcome operational problems encountered in 2007 and achieve sustainable gas production. Stable bottom hole flowing pressures were successfully achieved during a 6 day test with continuous pump operation. Sustained gas production was achieved with rates between 2000- 4000m3/day and cummulative gas volume in the surface of approximately 13,000m3. Temperature and pressure data measured at the bottom hole and gas and water production rates gave positive evidence for the high efficiency of gas

  15. Quality assurance and functionality tests on electrical components during the ATLAS IBL production

    International Nuclear Information System (INIS)

    Jentzsch, J

    2013-01-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all production staves before integration with the new beam pipe. This setup combines former ATLAS Pixel services and a new readout system, namely the RCE (Reconfigurable Cluster Element) system developed at SLAC. With this setup all production staves will be tested to ensure the installation of only those staves which fulfill the IBL criteria. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are performed on the individual components during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and assembled subsystems. The pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results from testing a prototype stave are presented and discussed.

  16. Quality assurance and functionality tests on electrical components during the ATLAS IBL production

    Science.gov (United States)

    Jentzsch, J.

    2013-02-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all production staves before integration with the new beam pipe. This setup combines former ATLAS Pixel services and a new readout system, namely the RCE (Reconfigurable Cluster Element) system developed at SLAC. With this setup all production staves will be tested to ensure the installation of only those staves which fulfill the IBL criteria. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are performed on the individual components during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and assembled subsystems. The pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results from testing a prototype stave are presented and discussed.

  17. HTTR hydrogen production system. Structure and main specifications of mock-up test facility (Contract research)

    International Nuclear Information System (INIS)

    Kato, Michio; Aita, Hideki; Inagaki, Yoshiyuki; Hayashi, Koji; Ohashi, Hirofumi; Sato, Hiroyuki; Iwatsuki, Jin; Takada, Shoji; Inaba, Yoshitomo

    2007-03-01

    The mock-up test facility was fabricated to investigate performance of the steam generator for mitigation of the temperature fluctuation of helium gas and transient behavior of the hydrogen production system for HTTR and to obtain experimental data for verification of a dynamic analysis code. The test facility has an approximate hydrogen production capacity of 120Nm 3 /h and the steam reforming process of methane; CH 4 +H 2 O=3H 2 +CO, was used for hydrogen production of the test facility. An electric heater was used as a heat source instead of the reactor in order to heat helium gas up to 880degC (4MPa) at the chemical reactor inlet which is the same temperature as the HTTR hydrogen production system. Fabrication of the test facility was completed in February in 2002, and seven cycle operations were carried out from March in 2002 to December in 2004. This report describes the structure and main specifications of the test facility. (author)

  18. Vitrification and Product Testing of AW-101 and AN-107 Pretreated Waste

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Gary L.; Greenwood, Lawrence R.; Piepel, Gregory F.; Schweiger, Michael J.; Smith, Harry D.; Urie, Michael W.; Wagner, Jerome J.

    2000-10-31

    The primary objective for vitrifying the LAW samples is to generate glass products for subsequent product testing. The work presented in this report is divided into 6 work elements: 1) Glass Fabrication, 2) Chemical Composition, 3) Radiochemical Composition, 4) Crystalline and Non-crystalline Phase Determination, and 5) Release Rate (Modified PCT). These work elements will help demonstrate the RPP-WTP projects ability to satisfy the product requirements concerning, chemical and radionuclide reporting, waste loading, identification and quantification of crystalline and non-crystalline phases, and waste form leachability. VOA, SVOA, dioxins, furans, PCBs, and total cyanide analyses will be reported in as separate document (WTP-RPT-005).

  19. MicroCHP: Overview of selected technologies, products and field test results

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Vollrad [Berliner Energieagentur GmbH, Franzoesische Strasse 23, 10117 Berlin (Germany); Klemes, Jiri; Bulatov, Igor [Centre for Process Integration, CEAS, The University of Manchester, P.O. Box 88, M60 1QD Manchester (United Kingdom)

    2008-11-15

    This paper gives an overview on selected microCHP technologies and products with the focus on Stirling and steam machines. Field tests in Germany, the UK and some other EC countries are presented, assessed and evaluated. Test results show the overall positive performance with differences in sectors (domestic vs. small business). Some negative experiences have been received, especially from tests with the Stirling engines and the free-piston steam machine. There are still obstacles for market implementation. Further projects and tests of microCHP are starting in various countries. When positive results will prevail and deficiencies are eliminated, a way to large-scale production and market implementation could be opened. (author)

  20. Thin blue lines: product placement and the drama of pregnancy testing in British cinema and television.

    Science.gov (United States)

    Olszynko-Gryn, Jesse

    2017-09-01

    This article uses the case of pregnancy testing in Britain to investigate the process whereby new and often controversial reproductive technologies are made visible and normalized in mainstream entertainment media. It shows how in the 1980s and 1990s the then nascent product placement industry was instrumental in embedding pregnancy testing in British cinema and television's dramatic productions. In this period, the pregnancy-test close-up became a conventional trope and the thin blue lines associated with Unilever's Clearblue rose to prominence in mainstream consumer culture. This article investigates the aestheticization of pregnancy testing and shows how increasingly visible public concerns about 'schoolgirl mums', abortion and the biological clock, dramatized on the big and small screen, propelled the commercial rise of Clearblue. It argues that the Clearblue close-up ambiguously concealed as much as it revealed; abstraction, ambiguity and flexibility were its keys to success.

  1. Light composite mirrors for RICH detectors Production, characterisation and stability tests

    CERN Document Server

    Bellunato, T F; Calvi, M; Chignoli, F; D'Ambrosio, C; Matteuzzi, C; Musy, M; Perego, D L

    2005-01-01

    The production of lightweight composite mirror prototypes suitable for application in Ring Imaging Cherenkov (RICH) detectors is described. The goal is the use of such mirrors whenever material budget is a concern. The manufacturing technique is described in detail, together with the achieved results in terms of optical quality. Several ageing tests have been performed on some of the prototypes. The results of these tests are reported.

  2. Hardware design for the production of NTD silicon in the Advanced Test Reactor

    International Nuclear Information System (INIS)

    Schell, M.J.

    1984-01-01

    The Advanced Test Reactor (ATR) is a 250-MW(t) materials testing and nuclear research facility operated for EG and G Idaho, Inc. The unique capabilities of the ATR can be readily adapted via hardware to produce large quantitities of large-diameter (20 cm plus) doped silicon crystals. Conservative estimates place the production capability in excess of 15 metric tons per year. The proposed hardware is based upon a closed-loop, hydraulic-shuttle tube system

  3. Agreement among the Productivity Components of Eight Presenteeism Tests in a Sample of Health Care Workers.

    Science.gov (United States)

    Thompson, Angus H; Waye, Arianna

    2018-06-01

    Presenteeism (reduced productivity at work) is thought to be responsible for large economic costs. Nevertheless, much of the research supporting this is based on self-report questionnaires that have not been adequately evaluated. To examine the level of agreement among leading tests of presenteeism and to determine the inter-relationship of the two productivity subcategories, amount and quality, within the context of construct validity and method variance. Just under 500 health care workers from an urban health area were asked to complete a questionnaire containing the productivity items from eight presenteeism instruments. The analysis included an examination of test intercorrelations, separately for amount and quality, supplemented by principal-component analyses to determine whether either construct could be described by a single factor. A multitest, multiconstruct analysis was performed on the four tests that assessed both amount and quality to test for the relative contributions of construct and method variance. A total of 137 questionnaires were completed. Agreement among tests was positive, but modest. Pearson r ranges were 0 to 0.64 (mean = 0.32) for Amount and 0.03 to 0.38 (mean = 0.25) for Quality. Further analysis suggested that agreement was influenced more by method variance than by the productivity constructs the tests were designed to measure. The results suggest that presenteeism tests do not accurately assess work performance. Given their importance in the determination of policy-relevant conclusions, attention needs to be given to test improvement in the context of criterion validity assessment. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  4. Future Food Production System Development Pulling From Space Biology Crop Growth Testing in Veggie

    Science.gov (United States)

    Massa, Gioia; Romeyn, Matt; Fritsche, Ralph

    2017-01-01

    Preliminary crop testing using Veggie indicates the environmental conditions provided by the ISS are generally suitable for food crop production. When plant samples were returned to Earth for analysis, their levels of nutrients were comparable to Earth-grown ground controls. Veggie-grown produce food safety microbiology analysis indicated that space-grown crops are safe to consume. Produce sanitizing wipes were used on-orbit to further reduce risk of foodborne illness. Validation growth tests indicated abiotic challenges of insufficient or excess fluid delivery, potentially reduced air flow leading to excess water, elevated CO2 leading to physiological responses, and microorganisms that became opportunistic pathogens. As NASA works to develop future space food production, several areas of research to define these systems pull from the Veggie technology validation tests. Research into effective, reusable water delivery and water recovery methods for future food production systems arises from abiotic challenges observed. Additionally, impacts of elevated CO2 and refinement of fertilizer and light recipes for crops needs to be assessed. Biotic pulls include methods or technologies to effectively sanitize produce with few consumables and low inputs; work to understand the phytomicrobiome and potentially use it to protect crops or enhance growth; selection of crops with high harvest index and desirable flavors for supplemental nutrition; crops that provide psychosocial benefits, and custom space crop development. Planning for future food production in a deep space gateway or a deep space transit vehicle requires methods of handling and storing seeds, and ensuring space seeds are free of contaminants and long-lived. Space food production systems may require mechanization and autonomous operation, with preliminary testing initiated to identify operations and capabilities that are candidates for automation. Food production design is also pulling from Veggie logistics

  5. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  6. Improving Papanicolaou test quality and reducing medical errors by using Toyota production system methods.

    Science.gov (United States)

    Raab, Stephen S; Andrew-Jaja, Carey; Condel, Jennifer L; Dabbs, David J

    2006-01-01

    The objective of the study was to determine whether the Toyota production system process improves Papanicolaou test quality and patient safety. An 8-month nonconcurrent cohort study that included 464 case and 639 control women who had a Papanicolaou test was performed. Office workflow was redesigned using Toyota production system methods by introducing a 1-by-1 continuous flow process. We measured the frequency of Papanicolaou tests without a transformation zone component, follow-up and Bethesda System diagnostic frequency of atypical squamous cells of undetermined significance, and diagnostic error frequency. After the intervention, the percentage of Papanicolaou tests lacking a transformation zone component decreased from 9.9% to 4.7% (P = .001). The percentage of Papanicolaou tests with a diagnosis of atypical squamous cells of undetermined significance decreased from 7.8% to 3.9% (P = .007). The frequency of error per correlating cytologic-histologic specimen pair decreased from 9.52% to 7.84%. The introduction of the Toyota production system process resulted in improved Papanicolaou test quality.

  7. Research on test of product based on spatial sampling criteria and variable step sampling mechanism

    Science.gov (United States)

    Li, Ruihong; Han, Yueping

    2014-09-01

    This paper presents an effective approach for online testing the assembly structures inside products using multiple views technique and X-ray digital radiography system based on spatial sampling criteria and variable step sampling mechanism. Although there are some objects inside one product to be tested, there must be a maximal rotary step for an object within which the least structural size to be tested is predictable. In offline learning process, Rotating the object by the step and imaging it and so on until a complete cycle is completed, an image sequence is obtained that includes the full structural information for recognition. The maximal rotary step is restricted by the least structural size and the inherent resolution of the imaging system. During online inspection process, the program firstly finds the optimum solutions to all different target parts in the standard sequence, i.e., finds their exact angles in one cycle. Aiming at the issue of most sizes of other targets in product are larger than that of the least structure, the paper adopts variable step-size sampling mechanism to rotate the product specific angles with different steps according to different objects inside the product and match. Experimental results show that the variable step-size method can greatly save time compared with the traditional fixed-step inspection method while the recognition accuracy is guaranteed.

  8. 76 FR 1067 - Testing of Certain High Production Volume Chemicals; Second Group of Chemicals

    Science.gov (United States)

    2011-01-07

    ... Mfg & NOES (number based criteria based criteria significant chemicals (lbs) industrial of workers... 2070-AD16 Testing of Certain High Production Volume Chemicals; Second Group of Chemicals AGENCY... section 4(a)(1)(B) of the Toxic Substances Control Act (TSCA) to require manufacturers, importers, and...

  9. Covariance functions across herd production levels for test day records on milk, fat, and protein yields

    NARCIS (Netherlands)

    Veerkamp, R.F.; Goddard, M.E.

    1998-01-01

    Multiple-trait BLUP evaluations of test day records require a large number of genetic parameters. This study estimated covariances with a reduced model that included covariance functions in two dimensions (stage of lactation and herd production level) and all three yield traits. Records came from

  10. Preparation results for lifetime test of conversion LEU fuel in plutonium production reactors

    International Nuclear Information System (INIS)

    Vatulin, A.; Stetskiy, Yu.; Kukharkin, N.; Kalougin, A.; Gavrilov, P.; Ivanov, A.

    1999-01-01

    The program of converting Russian production reactors for the purpose to stop their plutonium fabrication is currently in progress. The program also provides for operation of these reactors under the conversion mode with using of low-enriched fuel (LEU). LEU fuel elements were developed and activities related to their preparation for reactor tests were carried out. (author)

  11. 78 FR 41129 - Market Test of Experimental Product - International Merchandise Return Service-Non-Published Rates

    Science.gov (United States)

    2013-07-09

    ...--Non-Published Rates AGENCY: U.S. Postal Service\\TM\\. ACTION: Notice. SUMMARY: The Postal Service hereby gives notice of a market test for International Merchandise Return Service--Non-Published Rates in... Return Service (IMRS) Non-published Rate (NPR) experimental product on August 15, 2013. The Postal...

  12. An analysis of unit tests of a flight software product line

    NARCIS (Netherlands)

    Ganesan, D.; Lindvall, M.; McComas, D.; Bartholomew, M.; Slegel, S.; Medina, B.; Krikhaar, R.; Verhoef, C.; Dharmalingam, G.; Montgomery, L.P.

    2013-01-01

    This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software System (CFS) product line team at the NASA Goddard Space Flight Center (GSFC). The goal of the analysis is to understand, review, and recommend strategies for improving the CFS' existing unit

  13. Industrial Arts Test Development, Book III. Resource Items for Graphics Technology, Power Technology, Production Technology.

    Science.gov (United States)

    New York State Education Dept., Albany.

    This booklet is designed to assist teachers in developing examinations for classroom use. It is a collection of 955 objective test questions, mostly multiple choice, for industrial arts students in the three areas of graphics technology, power technology, and production technology. Scoring keys are provided. There are no copyright restrictions,…

  14. Faculty Rank System, Research Motivation, and Faculty Research Productivity: Measure Refinement and Theory Testing.

    Science.gov (United States)

    Tien, Flora F.; Blackburn, Robert T.

    1996-01-01

    A study explored the relationship between the traditional system of college faculty rank and faculty research productivity from the perspectives of behavioral reinforcement theory and selection function. Six hypotheses were generated and tested, using data from a 1989 national faculty survey. Results failed to support completely either the…

  15. Determination of γ value in equation of state of detonation products by cylinder test

    International Nuclear Information System (INIS)

    Hua Pinghuan

    2001-01-01

    A method for the determination of γ value in γ law equation of state (EOS) of detonation products (DP) by cylinder test (CT) is provided. The γ values determined by this method are not surely in agreement with that determined by free-surface velocity method (FVM), but they can be used to satisfactorily calculate DP's ability to do work

  16. Abrasion Testing of Products Containing Nanomaterials, SOP-R-2: Scientific Operating Procedure Series: Release (R)

    Science.gov (United States)

    2016-04-01

    Nanotechnologies -- Terminology and definitions for nano-objects -- Nanoparticle, nanofibre and nanoplate Definitions Abrasion - wearing away...ER D C SR -1 6- 2 Environmental Consequences of Nanotechnologies Abrasion Testing of Products Containing Nanomaterials, SOP-R-2...ERDC online library at http://acwc.sdp.sirsi.net/client/default. Environmental Consequences of Nanotechnologies ERDC SR-16-2 April 2016

  17. Production and cost of a live skyline cable yarder tested in Appalachia

    Science.gov (United States)

    Edward L. Fisher; Harry G. Gibson; Cleveland J. Biller

    1980-01-01

    Logging systems that are profitable and environmentally acceptable are needed in Appalachian hardwood forests. Small, mobile cable yarders show promise in meeting both economic and environmental objectives. One such yarder, the Ecologger, was tested on the Jefferson National Forest near Marion, Virginia. Production rates and costs are presented for the system along...

  18. The influence of plants on productivity : A critical assessment of research findings and test methods

    NARCIS (Netherlands)

    Bakker, I; van der Voordt, Theo

    2010-01-01

    Purpose
    This paper aims to review available research into the impact of plants on people and labour productivity in order to test a number of hypotheses and the reliability and validity of “evidence based” statements.
    Methodology
    An extended literature review has been conducted of

  19. Toward a generic approach for : Stress testing of drug substances and drug products

    NARCIS (Netherlands)

    Klick, Silke; Muijselaar, Pim G.; Waterval, Joop; Eichinger, Thomas; Korn, Christian; Gerding, Thijs K.; Debets, Alexander J.; Sänger-Van De Griend, Cari; Van Den Beld, Cas; Somsen, Govert W.; De Jong, Gerhardus J.

    The Impurity Profiling Group has developed a generic approach for conducting stress testing on drug substances and drug products. The proposed strategy is evaluated and verified with historical data and new experiments. Results demonstrate that the proposed approach is reasonable and generates

  20. Scoping assessment on medical isotope production at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Scott, S.W.

    1997-01-01

    The Scoping Assessment addresses the need for medical isotope production and the capability of the Fast Flux Test Facility to provide such isotopes. Included in the discussion are types of isotopes used in radiopharmaceuticals, which types of cancers are targets, and in what way isotopes provide treatment and/or pain relief for patients

  1. Making sense of knowledge productivity: beta testing the KP-enhancer

    NARCIS (Netherlands)

    Christiaan Stam

    2007-01-01

    Purpose – purpose of this article is to report about the progress of the development of a method that makes sense of knowledge productivity, in order to be able to give direction to knowledge management initiatives. Methodology/approach – the development and testing of the method is based on the

  2. Scoping assessment on medical isotope production at the Fast Flux Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Scott, S.W.

    1997-08-29

    The Scoping Assessment addresses the need for medical isotope production and the capability of the Fast Flux Test Facility to provide such isotopes. Included in the discussion are types of isotopes used in radiopharmaceuticals, which types of cancers are targets, and in what way isotopes provide treatment and/or pain relief for patients.

  3. GCSE Students' Attitudes to Dissection and Using Animals in Research and Product Testing.

    Science.gov (United States)

    Lock, Roger

    1995-01-01

    Questionnaires from students passing the General Certificate of Secondary Education (GCSE) that explored attitudes to dissection and using animals in product testing administered to (n=469) students ages 14-15 showed a high level of support for peers who object to dissection, although objectors are likely to be met with derogatory comments,…

  4. Characterisation and full-scale production testing of multifunctional surfaces for deep drawing applications

    DEFF Research Database (Denmark)

    Godi, Alessandro; Grønbæk, J.; De Chiffre, Leonardo

    2017-01-01

    assisted polishing. Advanced methods are employed to characterise the tools' surface topographies, detecting the surface features and analysing them separately according to their specific function. Four different multifunctional dies as well as two un-textured references are selected for testing. The tests......Full-scale deep drawing tests using tools featuring multifunctional surfaces are carried out in a production environment. Multifunctional tools display regularly spaced, transversal grooves for lubricant retention obtained by hard-turning, separated by smooth bearing plateaus realized by robot...

  5. A production throughput forecasting system in an automated hard disk drive test operation using GRNN

    Energy Technology Data Exchange (ETDEWEB)

    Samattapapong, N.; Afzulpurkar, N.

    2016-07-01

    The goal of this paper is to develop a pragmatic system of a production throughput forecasting system for an automated test operation in a hard drive manufacturing plant. The accurate forecasting result is necessary for the management team to response to any changes in the production processes and the resources allocations. In this study, we design a production throughput forecasting system in an automated test operation in hard drive manufacturing plant. In the proposed system, consists of three main stages. In the first stage, a mutual information method was adopted for selecting the relevant inputs into the forecasting model. In the second stage, a generalized regression neural network (GRNN) was implemented in the forecasting model development phase. Finally, forecasting accuracy was improved by searching the optimal smoothing parameter which selected from comparisons result among three optimization algorithms: particle swarm optimization (PSO), unrestricted search optimization (USO) and interval halving optimization (IHO). The experimental result shows that (1) the developed production throughput forecasting system using GRNN is able to provide forecasted results close to actual values, and to projected the future trends of production throughput in an automated hard disk drive test operation; (2) An IHO algorithm performed as superiority appropriate optimization method than the other two algorithms. (3) Compared with current forecasting system in manufacturing, the results show that the proposed system’s performance is superior to the current system in prediction accuracy and suitable for real-world application. The production throughput volume is a key performance index of hard disk drive manufacturing systems that need to be forecast. Because of the production throughput forecasting result is useful information for management team to respond to any changing in production processes and resources allocation. However, a practically forecasting system for

  6. Fission product release measured during fuel damage tests at the Power Burst Facility

    International Nuclear Information System (INIS)

    Osetek, D.J.; Hartwell, J.K.; Vinjamuri, K.; Cronenberg, A.W.

    1985-01-01

    Results are presented of fission product release behavior observed during four severe fuel damage tests on bundles of UO 2 fuel rods. Transient temperatures up to fuel melting were obtained in the tests that included both rapid quench and slow cooldown, low and high (36 GWd/t) burnup fuel and the addition of Ag-In-Cd control rods. Release fractions of major fission product species and release rates of noble gas species are reported. Significant differences in release behavior are discussed between heatup and cooldown periods, low and high burnup fuel and long- and short-lived fission products. Explanations are offered for the probable reasons for the observed differences and recommendations for further studies are given

  7. Accelerated Stress Testing of Multi-Source LED Products: Horticulture Lamps and Tunable-White Modules

    Energy Technology Data Exchange (ETDEWEB)

    Lynn Davis, Kelley Rountree, Karmann Mills

    2018-03-30

    This report discusses the use of accelerated stress testing (AST) to provide insights into the long-term behavior of commercial products utilizing different types of mid-power LEDs (MP-LEDs) integrated into the same LED module. Test results are presented from two commercial lamps intended for use in horticulture applications and one tunable-white LED module intended for use in educational and office lighting applications. Each of these products is designed to provide a custom spectrum for their targeted applications and each achieves this goal in different ways. Consequently, a comparison of the long-term stability of these devices will provide insights regarding approaches that could be used to possibly lengthen the lifetime of SSL products.

  8. Results of fission product release from intermediate-scale MCCI [molten core-concrete interaction] tests

    International Nuclear Information System (INIS)

    Spencer, B.W.; Thompson, D.H.; Fink, J.K.; Gunther, W.H.; Sehgal, B.R.

    1988-01-01

    A program of reactor-material molten core-concrete interaction (MCCI) tests and related analyses are under way at Argonne National Laboratory under sponsorship of the Electric Power Research Institute (EPRI). The particular objective of these tests is to provide data pertaining to the release of nonvolatile fission products such as La, Ba, and Sr, plus other aerosol materials, from the coupled thermal-hydraulic and chemical processes of the MCCI. The first stages of the program involving small and intermediate-scale tests have been completed. Three small-scale tests (/approximately/5 kg corium) and nine intermediate-scale tests (/approximately/30 kg corium) were performed between September 1985 and September 1987. Real reactor materials were used in these tests. Sustained internal heat generation at nominally 1 kW per kg of melt was provided by direct electrical heating of the corium mixture. MCCI tests were performed with both fully and partially oxidized corium mixtures that contained a variety of nonradioactive materials such as La 2 O 3 , BaO, and SrO to represent fission products. Both limestone/common sand and basaltic concrete basemats were used. The system was instrumented for characterization of the thermal hydraulic, chemical, gas release, and aerosol release processes

  9. Hanford Immobilized LAW Product Acceptance: Tanks Focus Area Testing Data Package II

    International Nuclear Information System (INIS)

    Schulz, Rebecca L.; Lorier, Troy H.; Peeler, David K.; Brown, Kevin G.; Reamer, Irene A.; Vienna, John D.; Jiricka, Antonin; Jorgensen, Benaiah M.; Smith, Donald E.

    2001-01-01

    This report is a continuation of the Hanford Immobilized Low Activity Waste (LAW) Product Acceptance (HLP): Initial Tanks Focus Area Testing Data Package (Vienna (and others) 2000). In addition to new 5000-h product consistency test (PCT), vapor hydration test (VHT), and alteration products data, some previously reported data together with relevant background information are included for an easily accessible source of reference when comparing the response of the various glasses to different test conditions. A matrix of 55 glasses was developed and tested to identify the impact of glass composition on long-term corrosion behavior and to develop an acceptable composition region for Hanford LAW glasses. Of the 55 glasses, 45 were designed to systematically vary the glass composition, and 10 were selected because large and growing databases on their corrosion characteristics had accumulated. The targeted and measured compositions of these glasses are found in the Appendix A. All glasses were fabricated according to standard procedures and heat treated to simulate the slow cooling that will occur in a portion of the waste glass after vitrification in the planned treatment facility at Hanford

  10. DPRK's 4{sup th} Nuclear Test and its Tritium Production

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Soo; Lee, Sang Joon; Chang, Sun Young [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2016-05-15

    On January 6, 2016 at 10:30am, the artificial earthquake in the DPRK was detected by multiple international seismic organizations. After 2 hours, the DPRK announced on state TV that 'The first H-bomb test was successfully conducted in the DPRK at 10:00 am on Wednesday, Juche 105(2016), pursuant to the strategic determination of the ruling communist party.' There has been a doubt about the real nature of the DPRK's 4th nuclear test, since 2 months have been passed after its nuclear test. To analyze the nature of the DPRK's nuclear test, it is necessary to check possible options for production of essential materials. The pathways to produce nuclear fusion material (tritium) and to have a relatively high possibility for the DPRK are described in this article. Tritium is key material for H-bomb. And there are two options for the DPRK which are 1) production and 2) illicit trafficking. And this study is focused on production possibility of DPRK. Determination of the nature of DPRK's nuclear test is very hard issue.

  11. Development of control technology for HTTR hydrogen production system with mock-up test facility

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo; Takeda, Tetsuaki; Hayashi, Koji; Takada, Shoji; Inagaki, Yoshiyuki

    2006-01-01

    The Japan Atomic Energy Agency has been planning the demonstration test of hydrogen production with the High Temperature Engineering Test Reactor (HTTR). In a HTTR hydrogen production system (HTTR-H2), it is required to control a primary helium temperature within an allowable value at a reactor inlet to prevent a reactor scram. A cooling system for a secondary helium with a steam generator (SG) and a radiator is installed at the downstream of a chemical rector in a secondary helium loop in order to mitigate the thermal disturbance caused by the hydrogen production system. Prior to HTTR-H2, the simulation test with a mock-up test facility has been carried out to establish the controllability on the helium temperature using the cooling system against the loss of chemical reaction. It was confirmed that the fluctuations of the helium temperature at chemical reactor outlet, more than 200 K, at the loss of chemical reaction could be successfully mitigated within the target of ±10 K at SG outlet. A dynamic simulation code of the cooling system for HTTR-H2 was verified with the obtained test data

  12. DPRK's 4"t"h Nuclear Test and its Tritium Production

    International Nuclear Information System (INIS)

    Kim, Min Soo; Lee, Sang Joon; Chang, Sun Young

    2016-01-01

    On January 6, 2016 at 10:30am, the artificial earthquake in the DPRK was detected by multiple international seismic organizations. After 2 hours, the DPRK announced on state TV that 'The first H-bomb test was successfully conducted in the DPRK at 10:00 am on Wednesday, Juche 105(2016), pursuant to the strategic determination of the ruling communist party.' There has been a doubt about the real nature of the DPRK's 4th nuclear test, since 2 months have been passed after its nuclear test. To analyze the nature of the DPRK's nuclear test, it is necessary to check possible options for production of essential materials. The pathways to produce nuclear fusion material (tritium) and to have a relatively high possibility for the DPRK are described in this article. Tritium is key material for H-bomb. And there are two options for the DPRK which are 1) production and 2) illicit trafficking. And this study is focused on production possibility of DPRK. Determination of the nature of DPRK's nuclear test is very hard issue

  13. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    Science.gov (United States)

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  14. Characterization of currently marketed heparin products: key tests for LMWH quality assurance.

    Science.gov (United States)

    Ye, Hongping; Toby, Timothy K; Sommers, Cynthia D; Ghasriani, Houman; Trehy, Michael L; Ye, Wei; Kolinski, Richard E; Buhse, Lucinda F; Al-Hakim, Ali; Keire, David A

    2013-11-01

    During the 2007-2008 heparin crisis it was found that the United States Pharmacopeia (USP) testing monograph for heparin sodium or low molecular weight heparins did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS). In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to detect not only the contaminant OSCS, but also to improve assurance of quality and purity of these drug products. The USP monographs for the low molecular weight heparins (LMWHs) approved for use in the United States (dalteparin, tinzaparin and enoxaparin) are also undergoing revision to include many of the same tests used for heparin sodium, including; one-dimensional (1D) 500 MHz (1)H NMR, SAX-HPLC, percent galactosamine in total hexosamine and anticoagulation time assays with purified Factor IIa or Factor Xa. These tests represent orthogonal approaches for heparin identification, measurement of bioactivity and for detection of process impurities or contaminants in these drug products. Here we describe results from a survey of multiple lots from three types of LMWHs in the US market which were collected after the 2009 heparin sodium monograph revision. In addition, innovator and generic versions of formulated enoxaparin products purchased in 2011 are compared using these tests and found to be highly similar within the discriminating power of the assays applied. Published by Elsevier B.V.

  15. Non-destructive testing method for determining the solvent diffusion coefficient in the porous materials products

    Science.gov (United States)

    Belyaev, V. P.; Mishchenko, S. V.; Belyaev, P. S.

    2018-01-01

    Ensuring non-destructive testing of products in industry is an urgent task. Most of the modern methods for determining the diffusion coefficient in porous materials have been developed for bodies of a given configuration and size. This leads to the need for finished products destruction to make experimental samples from them. The purpose of this study is the development of a dynamic method that allows operatively determine the diffusion coefficient in finished products from porous materials without destroying them. The method is designed to investigate the solvents diffusion coefficient in building constructions from materials having a porous structure: brick, concrete and aerated concrete, gypsum, cement, gypsum or silicate solutions, gas silicate blocks, heat insulators, etc. A mathematical model of the method is constructed. The influence of the design and measuring device operating parameters on the method accuracy is studied. The application results of the developed method for structural porous products are presented.

  16. A comparison of immunotoxic effects of nanomedicinal products with regulatory immunotoxicity testing requirements

    Directory of Open Access Journals (Sweden)

    Giannakou C

    2016-06-01

    Full Text Available Christina Giannakou,1,2 Margriet VDZ Park,1 Wim H de Jong,1 Henk van Loveren,1,2 Rob J Vandebriel,1 Robert E Geertsma1 1Centre for Health Protection, National Institute for Public Health and the Environment (RIVM, Bilthoven, 2Department of Toxicogenomics, Maastricht University, Maastricht, the Netherlands Abstract: Nanomaterials (NMs are attractive for biomedical and pharmaceutical applications because of their unique physicochemical and biological properties. A major application area of NMs is drug delivery. Many nanomedicinal products (NMPs currently on the market or in clinical trials are most often based on liposomal products or polymer conjugates. NMPs can be designed to target specific tissues, eg, tumors. In virtually all cases, NMPs will eventually reach the immune system. It has been shown that most NMs end up in organs of the mononuclear phagocytic system, notably liver and spleen. Adverse immune effects, including allergy, hypersensitivity, and immunosuppression, have been reported after NMP administration. Interactions of NMPs with the immune system may therefore constitute important side effects. Currently, no regulatory documents are specifically dedicated to evaluate the immunotoxicity of NMs or NMPs. Their immunotoxicity assessment is performed based on existing guidelines for conventional substances or medicinal products. Due to the unique properties of NMPs when compared with conventional medicinal products, it is uncertain whether the currently prescribed set of tests provides sufficient information for an adequate evaluation of potential immunotoxicity of NMPs. The aim of this study was therefore, to compare the current regulatory immunotoxicity testing requirements with the accumulating knowledge on immunotoxic effects of NMPs in order to identify potential gaps in the safety assessment. This comparison showed that immunotoxic effects, such as complement activation-related pseudoallergy, myelosuppression, inflammasome

  17. Disintegration Test of Health Food Products Containing Ginkgo Biloba L. or Vitex Agnus-Castus L. in the Japanese Market

    Science.gov (United States)

    Sato-Masumoto, Naoko; Masada, Sayaka; Takahashi, Satoshi; Terasaki, Sachiko; Yokota, Yoichi; Hakamatsuka, Takashi; Goda, Yukihiro

    2015-01-01

    For many years now, a number of Western herbs have been widely used in health food products in Japan and as pharmaceuticals in Europe. There are few or no mandated criteria concerning the quality of these herbal health food products, thus clarification is warranted. Here, we performed disintegration tests of 26 pharmaceutical and health food products containing the Western herbs ginkgo leaf and chaste tree fruit, in accord with the Japanese Pharmacopoeia. All eight pharmaceutical herbal products found in the European market completely disintegrated within the defined test time, and 11 of the 18 tested herbal products distributed as health foods in Japan disintegrated. Among the incompatible products identified in the Pharmacopoeia test, some products remained intact after incubation in water for 60 min. To ensure the efficacy of Western herbal products sold as health food in Japan, quality control, including disintegration, is therefore recommended, even though these products are not regulated under the Pharmaceutical Affairs Law. PMID:28930200

  18. Disintegration Test of Health Food Products Containing Ginkgo Biloba L. or Vitex Agnus-Castus L. in the Japanese Market.

    Science.gov (United States)

    Sato-Masumoto, Naoko; Masada, Sayaka; Takahashi, Satoshi; Terasaki, Sachiko; Yokota, Yoichi; Hakamatsuka, Takashi; Goda, Yukihiro

    2015-04-23

    For many years now, a number of Western herbs have been widely used in health food products in Japan and as pharmaceuticals in Europe. There are few or no mandated criteria concerning the quality of these herbal health food products, thus clarification is warranted. Here, we performed disintegration tests of 26 pharmaceutical and health food products containing the Western herbs ginkgo leaf and chaste tree fruit, in accord with the Japanese Pharmacopoeia. All eight pharmaceutical herbal products found in the European market completely disintegrated within the defined test time, and 11 of the 18 tested herbal products distributed as health foods in Japan disintegrated. Among the incompatible products identified in the Pharmacopoeia test, some products remained intact after incubation in water for 60 min. To ensure the efficacy of Western herbal products sold as health food in Japan, quality control, including disintegration, is therefore recommended, even though these products are not regulated under the Pharmaceutical Affairs Law.

  19. 40 CFR 1051.305 - How must I prepare and test my production-line vehicles or engines?

    Science.gov (United States)

    2010-07-01

    ... production-line vehicles or engines? 1051.305 Section 1051.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Testing Production-Line Vehicles and Engines § 1051.305 How must I prepare and test my production...

  20. A product lifecycle management framework to support the exchange of prototyping and testing information

    Science.gov (United States)

    Toche Fumchum, Luc Boris

    2011-12-01

    The modern perspective on product life cycle and the rapid evolution of Information and Communication Technologies in general have opened a new era in product representation and product information sharing between participants, both inside and outside the enterprise and throughout the product life. In particular, the Product Development Process relies on cross-functional activities involving different domains of expertise that each have their own dedicated tools. This has generated new challenges in terms of collaboration and dissemination of information at large between companies or even within the same organization. Within this context, the work reported herein focuses on a specific stakeholder within product development activities - the prototyping and testing department. Its business is typically related to the planning and building of prototypes in order to perform specific tests on the future product or one of its sub-assemblies. The research project aims at investigating an appropriate framework that leverages configured engineering product information, based on complementary information structures, to share and exchange prototyping and testing information in a Product Lifecycle Management (PLM) perspective. As a first step, a case study based on the retrofit of an aircraft engine is deployed to implement a scenario demonstrating the functionalities to be available within the intended framework. For this purpose, complementary and configurable structures are simulated within the project's PLM system. In a second step are considered the software interoperability issues that don't only affect Design -- Testing interactions, but many other interfaces within either the company -- due to the silo-arrangement -- or the consortiums with partners, in which case the whole PLM platforms could simply be incompatible. A study based on an open source initiative and relying on an improved model of communication is described to show how two natively disparate PLM tools can

  1. Studying the co-evolution of production and test code in open source and industrial developer test processes through repository mining

    NARCIS (Netherlands)

    Zaidman, A.; Van Rompaey, B.; Van Deursen, A.; Demeyer, S.

    2010-01-01

    Many software production processes advocate rigorous development testing alongside functional code writing, which implies that both test code and production code should co-evolve. To gain insight in the nature of this co-evolution, this paper proposes three views (realized by a tool called TeMo)

  2. Comprehensive validation scheme for in situ fiber optics dissolution method for pharmaceutical drug product testing.

    Science.gov (United States)

    Mirza, Tahseen; Liu, Qian Julie; Vivilecchia, Richard; Joshi, Yatindra

    2009-03-01

    There has been a growing interest during the past decade in the use of fiber optics dissolution testing. Use of this novel technology is mainly confined to research and development laboratories. It has not yet emerged as a tool for end product release testing despite its ability to generate in situ results and efficiency improvement. One potential reason may be the lack of clear validation guidelines that can be applied for the assessment of suitability of fiber optics. This article describes a comprehensive validation scheme and development of a reliable, robust, reproducible and cost-effective dissolution test using fiber optics technology. The test was successfully applied for characterizing the dissolution behavior of a 40-mg immediate-release tablet dosage form that is under development at Novartis Pharmaceuticals, East Hanover, New Jersey. The method was validated for the following parameters: linearity, precision, accuracy, specificity, and robustness. In particular, robustness was evaluated in terms of probe sampling depth and probe orientation. The in situ fiber optic method was found to be comparable to the existing manual sampling dissolution method. Finally, the fiber optic dissolution test was successfully performed by different operators on different days, to further enhance the validity of the method. The results demonstrate that the fiber optics technology can be successfully validated for end product dissolution/release testing. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  3. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    CERN Document Server

    Jentzsch, J

    2013-01-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all production staves before integration with the new beam pipe. This setup combines former ATLAS Pixel services and a new readout system, namely the RCE (Reconfigurable Cluster Element) system developed at SLAC. With this setup all production staves will be tested to ensure the installation of only those staves which fulfill the IBL criteria. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are performed on the individual components during the various production steps of the I...

  4. Medicinal Plants Based Products Tested on Pathogens Isolated from Mastitis Milk

    Directory of Open Access Journals (Sweden)

    Claudia Pașca

    2017-09-01

    Full Text Available Bovine mastitis a major disease that is commonly associated with bacterial infection. The common treatment is with antibiotics administered intramammary into infected quarters of the udder. The excessive use of antibiotics leads to multidrug resistance and associated risks for human health. In this context, the search for alternative drugs based on plants has become a priority in livestock medicine. These products have a low manufacturing cost and no reports of antimicrobial resistance to these have been documented. In this context, the main objective of this study was to determine the antimicrobial effect of extracts and products of several indigenous, or acclimatized plants on pathogens isolated from bovine mastitis. A total of eleven plant alcoholic extracts and eight plant-derived products were tested against 32 microorganisms isolated from milk. The obtained results have shown an inhibition of bacterial growth for all tested plants, with better results for Evernia prunastri, Artemisia absinthium, and Lavandula angustifolia. Moreover, E. prunastri, Populus nigra, and L. angustifolia presented small averages of minimum inhibitory and bactericidal concentrations. Among the plant-derived products, three out of eight have shown a strong anti-microbial effect comparable with the effect of florfenicol and enrofloxacin, and better than individual plant extracts possibly due to synergism. These results suggest an important anti-microbial effect of these products on pathogens isolated from bovine mastitis with a possible applicability in this disease.

  5. Estimation of soil properties and free product volume from baildown tests

    International Nuclear Information System (INIS)

    Zhu, J.L.; Parker, J.C.; Lundy, D.A.; Zimmerman, L.M.

    1993-01-01

    Baildown tests, involving measurement of water and free product levels in a monitoring well after bailing, are often performed at spill sites to estimate the oil volume per unit area -- which the authors refer to as ''oil specific volume.'' Spill volume is estimated by integrating oil specific volume over the areal domain of the spill. Existing methods for interpreting baildown tests are based on grossly simplistic approximations of soil capillary properties that cannot accurately describe the transient well response. A model for vertical equilibrium oil distributions based on the van Genuchten capillary model has been documented and verified in the laboratory and in the field by various authors. The model enables oil specific volume and oil transmissivity to be determined as functions of well product thickness. This paper describes a method for estimating van Genuchten capillary parameters, as well as aquifer hydraulic conductivity, from baildown tests. The results yield the relationships of oil specific volume and oil transmissivity to apparent product thickness, which may be used, in turn, to compute spill volume and to model free product plume movement and free product recovery. The method couples a finite element model for radial flow of oil and water to a well with a nonlinear parameter estimation algorithm. Effects of the filter pack around the well in the fluid level response are considered explicitly by the model. The method, which is implemented in the program BAILTEST, is applied to field data from baildown tests. The results indicate that hydrographs of water and oil levels are accurately described by the model

  6. Nuclear waste glass product consistency test (PCT): Version 7.0. Revision 3

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Product Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Product Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 7.0 of the PCT procedure is attached. This draft version has been submitted to ASTM for full committee (C26, Nuclear Fuel Cycle) ballot after being balloted successfully through subcommittee C26.13 on Repository Waste Package Materials Testing

  7. LOFT/LP-FP-2, Loss of Fluid Test, Fission Product Release from Fuel

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The eighth OECD LOFT experiment was conducted on 7 March 1985. It was the second of the two experiments to be performed in the LOFT facility with intentional release of fission products. Its principal objectives were to determine the fission product release from the fuel during a severe fuel damage scenario and the subsequent transport of these fission products in a predominantly vapor/aerosol environment. This was the largest severe fuel damage experiment ever conducted, and serves as an important benchmark between smaller scale tests and the TMI-2 accident. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  8. A comparison of immunotoxic effects of nanomedicinal products with regulatory immunotoxicity testing requirements.

    Science.gov (United States)

    Giannakou, Christina; Park, Margriet Vdz; de Jong, Wim H; van Loveren, Henk; Vandebriel, Rob J; Geertsma, Robert E

    2016-01-01

    Nanomaterials (NMs) are attractive for biomedical and pharmaceutical applications because of their unique physicochemical and biological properties. A major application area of NMs is drug delivery. Many nanomedicinal products (NMPs) currently on the market or in clinical trials are most often based on liposomal products or polymer conjugates. NMPs can be designed to target specific tissues, eg, tumors. In virtually all cases, NMPs will eventually reach the immune system. It has been shown that most NMs end up in organs of the mononuclear phagocytic system, notably liver and spleen. Adverse immune effects, including allergy, hypersensitivity, and immunosuppression, have been reported after NMP administration. Interactions of NMPs with the immune system may therefore constitute important side effects. Currently, no regulatory documents are specifically dedicated to evaluate the immunotoxicity of NMs or NMPs. Their immunotoxicity assessment is performed based on existing guidelines for conventional substances or medicinal products. Due to the unique properties of NMPs when compared with conventional medicinal products, it is uncertain whether the currently prescribed set of tests provides sufficient information for an adequate evaluation of potential immunotoxicity of NMPs. The aim of this study was therefore, to compare the current regulatory immunotoxicity testing requirements with the accumulating knowledge on immunotoxic effects of NMPs in order to identify potential gaps in the safety assessment. This comparison showed that immunotoxic effects, such as complement activation-related pseudoallergy, myelosuppression, inflammasome activation, and hypersensitivity, are not readily detected by using current testing guidelines. Immunotoxicity of NMPs would be more accurately evaluated by an expanded testing strategy that is equipped to stratify applicable testing for the various types of NMPs.

  9. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo; Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B.

    2017-01-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ( 57 Co, 133 Ba and 137 Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  10. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B., E-mail: rodrigo.gontijo@cdtn.br, E-mail: mamede.mm@gmail.com [Universidade Federal de Minas Gerais (IMA/FM/UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ({sup 57}Co, {sup 133}Ba and {sup 137}Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  11. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 1)].

    Science.gov (United States)

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Tonooka, Hiroyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.

  12. Malaysian consumers’ awareness, perception, and attitude toward cosmetic products: Questionnaire development and pilot testing

    Science.gov (United States)

    Ayob, Ain; Awadh, Ammar Ihsan; Hadi, Hazrina; Jaffri, Juliana; Jamshed, Shazia; Ahmad, Hawa Mas Azmar

    2016-01-01

    Background: Increased usage of cosmetic products has caused a growing concern about the safety of these products, and yet little is known about cosmetics from the consumers’ perspective. Hence, this study's aim is to develop a valid and reliable tool for assessing consumers’ awareness, perceptions, and attitudes toward cosmetic products. Materials and Methods: A questionnaire was developed in the English language based on information collected from a literature search, in-depth interviews conducted with consumers prior to this study and consultations with experts. Subsequently, the questionnaire was subjected to translation, validation, and test-retest reliability. A final version of the questionnaire was piloted among 66 consumers via convenient sampling. A descriptive analysis was performed, and the internal consistency and the differences between variables in the questionnaire were analyzed. Results: The developed and translated questionnaire produced repeatable data for each of the domains (Spearman's correlation ≥ 0.7, P awareness, perceptions and attitudes indicates good internal consistency (Cronbach's alpha value of more than 0.7 for each domain). Significant differences were found between the perception scores for the race, religion, and monthly expenses for cosmetic products, respectively, and the same pattern was found for the attitude scores, but monthly expenses for cosmetic products was replaced by monthly income. Conclusion: The results achieved via the Bahasa Malaysia questionnaire indicated that the developed and translated questionnaire can be used as a valid and reliable tool for assessing consumers’ awareness, perceptions, and attitudes toward cosmetic products in Malaysia in future studies. PMID:27413348

  13. Earthworm cast production as a new behavioural biomarker for toxicity testing

    International Nuclear Information System (INIS)

    Capowiez, Yvan; Dittbrenner, Nils; Rault, Magali; Triebskorn, Rita; Hedde, Mickael; Mazzia, Christophe

    2010-01-01

    There is currently a lack of ecotoxicity tests adapted to earthworm species of higher ecological relevance and whose endpoints could be directly related to their ecological role in the soil. We propose a new and relatively simple ecotoxicity test based on the estimation of cast production (CP) by Lumbricus terrestris under laboratory conditions. CP was found to be linearly correlated to earthworm biomass and to be greatly influenced by soil water content. Azinphos-methyl had no effect on CP at all the concentrations tested. Significant decreases were observed at the normal application rate for other pesticides with (imidacloprid, carbaryl, methomyl) or without (ethyl-parathion and chlorpyrifos-ethyl) a clear concentration-effect response. For the highest concentration tested, reduction in CP varied between 35 and 67%. CP is straightforward and rapidly measured and ecologically meaningful. We thus believe it to be of great use as an endpoint in ecotoxicity testing. - Cast production of Lumbricus terrestris is affected by pesticides under laboratory conditions.

  14. Earthworm cast production as a new behavioural biomarker for toxicity testing

    Energy Technology Data Exchange (ETDEWEB)

    Capowiez, Yvan, E-mail: capowiez@avignon.inra.f [INRA, UR1115 ' Plantes et Systemes Horticoles' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Dittbrenner, Nils [INRA, UR1115 ' Plantes et Systemes Horticoles' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Animal Physiological Ecology, University of Tuebingen, Konrad-Adenauer-Str. 20, D-72072 Tuebingen (Germany); Rault, Magali [UAPV, UMR406 ' Abeilles et Environnement' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Triebskorn, Rita [Animal Physiological Ecology, University of Tuebingen, Konrad-Adenauer-Str. 20, D-72072 Tuebingen (Germany); Hedde, Mickael [INRA, UR251 ' PESSAC' , RD10, 78026 Versailles Cedex (France); Mazzia, Christophe [UAPV, UMR406 ' Abeilles et Environnement' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France)

    2010-02-15

    There is currently a lack of ecotoxicity tests adapted to earthworm species of higher ecological relevance and whose endpoints could be directly related to their ecological role in the soil. We propose a new and relatively simple ecotoxicity test based on the estimation of cast production (CP) by Lumbricus terrestris under laboratory conditions. CP was found to be linearly correlated to earthworm biomass and to be greatly influenced by soil water content. Azinphos-methyl had no effect on CP at all the concentrations tested. Significant decreases were observed at the normal application rate for other pesticides with (imidacloprid, carbaryl, methomyl) or without (ethyl-parathion and chlorpyrifos-ethyl) a clear concentration-effect response. For the highest concentration tested, reduction in CP varied between 35 and 67%. CP is straightforward and rapidly measured and ecologically meaningful. We thus believe it to be of great use as an endpoint in ecotoxicity testing. - Cast production of Lumbricus terrestris is affected by pesticides under laboratory conditions.

  15. Comparison of three techniques for production goat lentivirus antigen used in the agar gel immunodifusion test

    Directory of Open Access Journals (Sweden)

    Raymundo Rizaldo Pinheiro

    2005-12-01

    Full Text Available The Caprine Arthritis Encephalitis (CAE is a disease who cause considerable economic losses, including loss in the milk production and reduction of the useful life of the animal. In the diagnosis of this disease the agar gel immunodifusion test (AGID is used worldwide as the selection test. The objective of thid work was to test three different concentrations of bovine fetal serum (BFS in the production of the antigen (Ag for the diagnosis of the CAE virus (CAEV, to verify amongst the three methods the most efficient concentration and which the antigen concentration of the antigen produced is appropriate for the test. The method of the AMICON and the concentration of the Ag for dialysis was indicated, however the system AMICON, despite the implantation costs, promoted minor loss of antigen, little time expense in the processing and greater simplicity. With relation to the amount of BFS placed after the viral inoculation it was verified that 5% of BFS the amount that presented better resulted. The antigen concentration 100 times was more indicated, therefore it allowed the diagnosis of the CAEV for two proteins (gp 135 and p28. The concentration of the Ag for precipitation/ultracentrifugation, used for imunoenzimatic tests, did not present resulted satisfactory used in the AGID.

  16. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    OpenAIRE

    Jentzsch, J

    2012-01-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all produ...

  17. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  18. Testing of CFC replacement fluids for arc-induced toxic by-products

    Energy Technology Data Exchange (ETDEWEB)

    Cravey, W.R.; Goerz, D.A.; Hawley-Fedder, R.A.

    1993-06-01

    The authors have developed a unique test-stand for quantifying the generation of perfluoroisobutylene (PFIB) in chlorofluorocarbon (CFC) replacement fluids when they are subjected to high electrical stress/breakdown environments. PFIB is an extremely toxic gas with a threshold limit value of 10 ppbv as set by the American Conference of Governmental Industrial Hygienists. They have tested several new fluids from various manufacturers for their potential to generate PFIB. Their goal is to determine breakdown characteristics and quantify toxic by-products of these replacement fluids to determine a safe, usable alternative for present CFC`s.

  19. Keeping the Background Low: Production and Testing of the GERDA Phase II Detectors

    International Nuclear Information System (INIS)

    Hemmer, Sabine

    2013-06-01

    The Germanium Detector Array (GERDA) experiment at the INFN Laboratori Nazionali del Gran Sasso searches for neutrinoless double beta decay of 76 Ge. The first phase using ∼15 kg of coaxial germanium detectors is ongoing. In a second phase, additional ∼20 kg of newly produced Broad Energy Germanium (BEGe) detectors will be deployed. To limit the generation of cosmogenically induced radioisotopes, the exposure of the germanium to cosmic radiation during the detector production and testing was minimized. An acceptance and characterization campaign of the newly produced detectors was carried out at the HEROICA facility in the HADES underground laboratory in Mol, Belgium. An overview over the complete production process, from isotopic enrichment of the material to the detector testing protocol, is given. (authors)

  20. Results from a first production of enhanced Silicon Sensor Test Structures produced by ITE Warsaw

    Science.gov (United States)

    Bergauer, T.; Dragicevic, M.; Frey, M.; Grabiec, P.; Grodner, M.; Hänsel, S.; Hartmann, F.; Hoffmann, K.-H.; Hrubec, J.; Krammer, M.; Kucharski, K.; Macchiolo, A.; Marczewski, J.

    2009-01-01

    Monitoring the manufacturing process of silicon sensors is essential to ensure stable quality of the produced detectors. During the CMS silicon sensor production we were utilising small Test Structures (TS) incorporated on the cut-away of the wafers to measure certain process-relevant parameters. Experience from the CMS production and quality assurance led to enhancements of these TS. Another important application of TS is the commissioning of new vendors. The measurements provide us with a good understanding of the capabilities of a vendor's process. A first batch of the new TS was produced at the Institute of Electron Technology in Warsaw Poland. We will first review the improvements to the original CMS test structures and then discuss a selection of important measurements performed on this first batch.

  1. Results from a first production of enhanced Silicon Sensor Test Structures produced by ITE Warsaw

    Energy Technology Data Exchange (ETDEWEB)

    Bergauer, T. [Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfergasse 18, 1050 Vienna (Austria); Dragicevic, M. [Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfergasse 18, 1050 Vienna (Austria)], E-mail: dragicevic@oeaw.ac.at; Frey, M. [Institut fuer Experimentelle Kernphysik (IEKP), Universitaet Karlsruhe (Thailand) (Germany); Grabiec, P.; Grodner, M. [Institute of Electron Technology (ITE), Warsaw (Poland); Haensel, S. [Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfergasse 18, 1050 Vienna (Austria); Hartmann, F.; Hoffmann, K.-H. [Institut fuer Experimentelle Kernphysik (IEKP), Universitaet Karlsruhe (Thailand) (Germany); Hrubec, J.; Krammer, M. [Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfergasse 18, 1050 Vienna (Austria); Kucharski, K. [Institute of Electron Technology (ITE), Warsaw (Poland); Macchiolo, A. [Max-Planck-Institut fuer Physik (MPI), Munich (Germany); Marczewski, J. [Institute of Electron Technology (ITE), Warsaw (Poland)

    2009-01-01

    Monitoring the manufacturing process of silicon sensors is essential to ensure stable quality of the produced detectors. During the CMS silicon sensor production we were utilising small Test Structures (TS) incorporated on the cut-away of the wafers to measure certain process-relevant parameters. Experience from the CMS production and quality assurance led to enhancements of these TS. Another important application of TS is the commissioning of new vendors. The measurements provide us with a good understanding of the capabilities of a vendor's process. A first batch of the new TS was produced at the Institute of Electron Technology in Warsaw Poland. We will first review the improvements to the original CMS test structures and then discuss a selection of important measurements performed on this first batch.

  2. Neoclassical versus Frontier Production Models ? Testing for the Skewness of Regression Residuals

    DEFF Research Database (Denmark)

    Kuosmanen, T; Fosgerau, Mogens

    2009-01-01

    The empirical literature on production and cost functions is divided into two strands. The neoclassical approach concentrates on model parameters, while the frontier approach decomposes the disturbance term to a symmetric noise term and a positively skewed inefficiency term. We propose a theoreti......The empirical literature on production and cost functions is divided into two strands. The neoclassical approach concentrates on model parameters, while the frontier approach decomposes the disturbance term to a symmetric noise term and a positively skewed inefficiency term. We propose...... a theoretical justification for the skewness of the inefficiency term, arguing that this skewness is the key testable hypothesis of the frontier approach. We propose to test the regression residuals for skewness in order to distinguish the two competing approaches. Our test builds directly upon the asymmetry...

  3. Microseismic monitoring during production and reinjection tests in the Chipilapa geothermal field (El Salvador)

    International Nuclear Information System (INIS)

    Fabriol, H.; Beauce, A.; Jacobo, R.; Quijano, J.

    1992-01-01

    The microseismic monitoring of the Chipilapa geothermal field has investigated the microseismic activity prior to and during the production and injection tests of three wells drilled between 1989 and 1991. Two surveys were carried out, in 1988 and 1991-1992 respectively, in order to study the reservoir and its recharge and to monitor microseismicity induced by reinjection. Natural microseismicity is distributed around the known geothermal area, and related either to tectonic activity under the volcanic range sited at the south (and which is the upflow zone of the geothermal field) or to the Central Graben at the north. No evidences of induced microseismicity appeared at this stage of interpretation, probably due to the unfavourable conditions prevailing during the tests: Namely reinjection by gravity and low productivity

  4. Putting to point the production process of iodine-131 by dry distillation (Preoperational tests)

    International Nuclear Information System (INIS)

    Alanis M, J.

    2002-12-01

    With the purpose of putting to point the process of production of 131 I, one of the objectives of carrying out the realization of operational tests of the production process of iodine-131, it was of verifying the operation of each one of the following components: heating systems, vacuum system, mechanical system and peripheral equipment that are part of the production process of iodine-131, another of the objectives, was settling down the optimal parameters that were applied in each process during the obtaining of iodine-131, it is necessary to point out that this objective is very important, since the components of the equipment are new and its behavior during the process is different to the equipment where its were carried out the experimental studies. (Author)

  5. FFTF [Fast Flux Test Facility] performance measurements for safety, productivity and control

    International Nuclear Information System (INIS)

    Newland, D.J.; Praetorius, P.R.; Tomaszewski, T.A.

    1987-05-01

    A useful set of performance measurements for Safety, Productivity and Control has evolved at the Fast Flux Test Facility (FFTF). In response to declining budgets and the resulting need to safely manage a manpower rampdown, an ''Early Warning System'' was developed in 1984. Its purpose was to monitor the effects of the staffing rampdown such that appropriate remedial action could be taken to correct adverse trends before a significant problem occurred. 1 tab

  6. Development of a tornado safe room door from wood Products: door design and impact testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2016-01-01

    In this study, a tornado safe room door built from wood products and steel sheeting was developed and impact-tested according to tornado safe room standards. Results indicate that an door constructed from as few as two sheets of 23/32-in. (18.26-mm) construction-grade plywood and overlaid with 18-gauge (0.05-in.- (1.27- mm-) thick) steel can pass the required impact...

  7. $Z^{0}$ production as a test of nuclear effects at the LHC

    CERN Document Server

    Xiao Fei Zhang

    2002-01-01

    We predict the Z/sup 0/ transverse momentum distribution from proton- proton and nuclear collisions at the LHC. After demonstrating that higher-twist nuclear effects are very small, we propose Z/sup 0/ production as a precision test for leading-twist pQCD in the TeV energy region. We also point out that shadowing may result in unexpected phenomenology at the LHC. (21 refs).

  8. Z Production as a Test of Nuclear Effects at the LHC

    CERN Document Server

    Zhang, X; Zhang, Xiaofei; Fai, George

    2002-01-01

    We predict the Z transverse momentum distribution from proton-proton and nuclear collisions at the LHC. After demonstrating that higher-twist nuclear effects are very small, we propose $Z^0$ production as a precision test for leading-twist pQCD in the TeV energy region. We also point out that shadowing may result in unexpected phenomenology at the LHC.

  9. Fuel elements and fuel element materials. Experimental facilities for fission products lift-off tests

    International Nuclear Information System (INIS)

    Blanchard, R.J.; Veyrat, J.F.

    1978-01-01

    One of the hypothetical accidents on the HTGR primary cooling circuits is the failure of a circuit resulting in a depressurization in the primary loops of the reactor. There is a risk of release of fission products in relation to the size of the failure. Experimental facilities for HTGR tests were developed: an in pile helium loop Comedie and an out of pile helium loop

  10. Quantification of Plasmodiophora brassicae Using a DNA-Based Soil Test Facilitates Sustainable Oilseed Rape Production

    OpenAIRE

    Ann-Charlotte Wallenhammar; Albin Gunnarson; Fredrik Hansson; Anders Jonsson

    2016-01-01

    Outbreaks of clubroot disease caused by the soil-borne obligate parasite Plasmodiophora brassicae are common in oilseed rape (OSR) in Sweden. A DNA-based soil testing service that identifies fields where P. brassicae poses a significant risk of clubroot infection is now commercially available. It was applied here in field surveys to monitor the prevalence of P. brassicae DNA in field soils intended for winter OSR production and winter OSR field experiments. In 2013 in Scania, prior to plantin...

  11. Chemical Composition Analysis and Product Consistency Tests of the ORP Phase 5 Nepheline Study Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Caldwell, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, W. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-02-01

    In this report, the Savannah River National Laboratory (SRNL) provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high-level waste glass compositions fabricated by the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved models for the prediction of nepheline crystallization in support of the Hanford Tank Waste Treatment and Immobilization Plant (WTP).

  12. Level of use and safety of botanical products for itching vulvar dermatoses. Are patch tests useful?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa; Toni, Giulia; Minghetti, Sara; Tiengo, Silvia; Borghi, Alessandro

    2016-05-01

    Topical remedies based on botanical ingredients are popular. To assess: (i) the usage of botanical substances in subjects affected with itching and chronic vulvar complaints; (ii) the incidence of side-effects associated with their use and the frequency of contact allergy; (iii) the diagnostic usefulness of patch testing. Sixty-six patients were provided with a questionnaire to assess the prevalence and type of topical botanical preparations used and the occurrence of adverse reactions. Patients were patch tested with (i) the Italian baseline series, (ii) a topical medicament series, and (iii) a botanical series. Forty-two patients (63.6%) reported the use of natural topical products on the vulva. Seven (16.7%) noted adverse reactions; 27 showed positive reactions with the baseline series; 14 (21.2%) had at least one relevant reaction, mainly to allergens in topical products and cosmetics; and 2 (3%) showed positive reactions to the botanical series. Of the 7 patients complaining of adverse effects of botanical products, 3 (42.8%) showed relevant sensitization. The use of natural topical products is widespread among women affected with itching vulvar diseases. Contact dermatitis is a possible adverse effect. Botanical series are of questionable usefulness, owing to the wide variety of botanical ingredients. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Batch Test Screening of Industrial Product/Byproduct Filter Materials for Agricultural Drainage Water Treatment

    Directory of Open Access Journals (Sweden)

    Barry J. Allred

    2017-10-01

    Full Text Available Filter treatment may be a viable means for removing the nitrate (NO3−, phosphate (PO43−, and pesticides discharged with agricultural drainage waters that cause adverse environmental impacts within the U.S. on local, regional, and national scales. Laboratory batch test screening for agricultural drainage water treatment potential was conducted on 58 industrial product/byproduct filter materials grouped into six categories: (1 high carbon content media; (2 high iron content media; (3 high aluminum content media; (4 surfactant modified clay/zeolite; (5 coal combustion residuals; and (6 spent foundry sands. Based on a percent contaminant removal criteria of 75% or greater, seven industrial products/byproducts were found to meet this standard for NO3− alone, 44 met this standard for PO43−, and 25 met this standard for the chlorinated triazine herbicide, atrazine. Using a 50% or greater contaminant removal criteria, five of the industrial product/byproduct filter materials exhibited potential for removing NO3−, PO43−, and atrazine together; eight showed capability for combined NO3− and PO43− removal; 21 showed capability for combined PO43− and atrazine removal; and nine showed capability for combined NO3− and atrazine removal. The results of this study delineated some potential industrial product/byproduct filter materials for drainage water treatment; however, a complete feasibility evaluation for drainage water treatment of any of these filter materials will require much more extensive testing.

  14. LOFT/LP-FP-1B, Loss of Fluid Test, Fission Product Release Experiment

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The seventh OECD LOFT experiment was conducted on 19 December 1984. It was the first of the two experiments to be performed in the LOFT facility with intentional release of fission products. Its objectives were to obtain data on fission product release from the fuel-cladding gap into vapor and reflood water and to collect data on transport of these fission products through and out of the reactor coolant system. The experiment was initiated by a reactor scram with one second delayed opening of the quick-opening blowdown valves. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  15. Plant Atrium System for Food Production in NASA's Deep Space Habitat Tests

    Science.gov (United States)

    Massa, Gioia D.; Simpson, Morgan; Wheeler, Raymond M.; Newsham, Gerald; Stutte, Gary W.

    2013-01-01

    In preparation for future human exploration missions to space, NASA evaluates habitat concepts to assess integration issues, power requirements, crew operations, technology, and system performance. The concept of a Food Production System utilizes fresh foods, such as vegetables and small fruits, harvested on a continuous basis, to improve the crew's diet and quality of life. The system would need to fit conveniently into the habitat and not interfere with other components or operations. To test this concept, a plant growing "atrium" was designed to surround the lift between the lower and upper modules of the Deep Space Habitat and deployed at NASA Desert Research and Technology Studies (DRATS) test site in 2011 and at NASA Johnson Space Center in 2012. With this approach, no-utilized volume provided an area for vegetable growth. For the 2011 test, mizuna, lettuce, basil, radish and sweetpotato plants were grown in trays using commercially available red I blue LED light fixtures. Seedlings were transplanted into the atrium and cared for by the. crew. Plants were then harvested two weeks later following completion of the test. In 2012, mizuna, lettuce, and radish plants were grown similarly but under flat panel banks of white LEDs. In 2012, the crew went through plant harvesting, including sanitizing tlie leafy greens and radishes, which were then consumed. Each test demonstrated successful production of vegetables within a functional hab module. The round red I blue LEDs for the 2011 test lighting cast a purple light in the hab, and were less uniformly distributed over the plant trays. The white LED panels provided broad spectrum light with more uniform distribution. Post-test questionnaires showed that the crew enjoyed tending and consuming the plants and that the white LED light in 2012 provided welcome extra light for the main HAB AREA.

  16. [Replacement of dogs as research animals for the approval testing of plant protection products].

    Science.gov (United States)

    Box, Rainer J

    2006-01-01

    The replacement of animal testing using dogs for the registration of plant protection products requires a long-term step-by-step procedure. The first goal should be to achieve international agreement on using only one single study in dogs. This would result in a significant short-term reduction of the use of dogs for this purpose. The competent working groups both in the EU and the United States EPA have declared this to be their intended aim. In this context, the 90-day study is to be the preferred study from the scientific as well as the animal welfare points of view. It is proposed to set up an international expert task force within the next 12 months, which should seek to initiate a process of international harmonization of the testing requirements following the example of the International Conference of Harmonization of Technical Requirements for Medical Products, ICH. The goal should be to achieve international agreement on only one single study with dogs within the next 2 to 3 years. In addition, other valid scientific procedures, with which the use of dogs for testing can be reduced, should be critically assessed. A complete replacement of the use of dogs for plant protection product testing is suggested to take place at a later stage. This may be achieved by either deriving safety threshold values by applying a safety factor to chronic NOAEL values obtained in studies using rats for those groups of substances, for which there is evidence that the dog is the more sensitive species, or by combining the chronic rat study with other animal tests stipulated for the registration of pesticides.

  17. Hanford immobilized LAW product acceptance: Initial Tanks Focus Area testing data package

    Energy Technology Data Exchange (ETDEWEB)

    JD Vienna; A Jiricka; BP McGrail; BM Jorgensen; DE Smith; BR Allen; JC Marra; DK Peeler; KG Brown; IA Reamer; WL Ebert

    2000-03-08

    The Hanford Site's mission has been to produce nuclear materials for the US Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during plutonium production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The total volume of LAW requiring immobilization will include the LAW separated from the tank waste, as well as new wastes generated by the retrieval, pretreatment, and immobilization processes. Per the Tri-Party Agreement (1994), both the LAW and HLW will be vitrified. It has been estimated that vitrification of the LAW waste will result in over 500,000 metric tons or 200,000 m{sup 3} of immobilized LAW (ILAW) glass. The ILAW glass is to be disposed of onsite in a near-surface burial facility. It must be demonstrated that the disposal system will adequately retain the radionuclides and prevent contamination of the surrounding environment. This report describes a study of the impacts of systematic glass-composition variation on the responses from accelerated laboratory corrosion tests of representative LAW glasses. A combination of two tests, the product consistency test and vapor-hydration test, is being used to give indictations of the relative rate at which a glass could be expected to corrode in the burial scenario.

  18. Juvenile Animal Testing: Assessing Need and Use in the Drug Product Label.

    Science.gov (United States)

    Baldrick, Paul

    2018-01-01

    Juvenile animal testing has become an established part of drug development to support safe clinical use in the human pediatric population and for eventual drug product label use. A review of European Paediatric Investigation Plan decisions showed that from 2007 to mid-2017, 229 drugs had juvenile animal work requested, almost exclusively incorporating general toxicology study designs, in rat (57.5%), dog (8%), mouse (4.5%), monkey (4%), pig (2%), sheep (1%), rabbit (1%), hamster (0.5%), and species not specified (21.5%). A range of therapeutic areas were found, but the most common areas were infectious diseases (15%), endocrinology (13.5%), oncology (13%), neurology (11%), and cardiovascular diseases (10%). Examination of major clinical indications within these therapeutic areas showed some level of consistency in the species of choice for testing and the pediatric age that required support. Examination of juvenile animal study findings presented in product labels raises questions around how useful the data are to allow prescribing the drug to a child. It is hopeful that the new ICH S11 guideline "Nonclinical Safety Testing in Support of Development of Pediatric Medicines" currently in preparation will aid drug developers in clarifying the need for juvenile animal studies as well as in promoting a move away from toxicology studies with a conventional design. This would permit more focused testing to examine identified areas of toxicity or safety concerns and clarify the presentation/interpretation of juvenile animal study findings for proper risk assessment by a drug prescriber.

  19. Hanford immobilized LAW product acceptance: Initial Tanks Focus Area testing data package

    International Nuclear Information System (INIS)

    JD Vienna; A Jiricka; BP McGrail; BM Jorgensen; DE Smith; BR Allen; JC Marra; DK Peeler; KG Brown; IA Reamer; WL Ebert

    2000-01-01

    The Hanford Site's mission has been to produce nuclear materials for the US Department of Energy (DOE) and its predecessors. A large inventory of radioactive and mixed waste, largely generated during plutonium production, exists in 177 underground single- and double-shell tanks. These wastes are to be retrieved and separated into low-activity waste (LAW) and high-level waste (HLW) fractions. The total volume of LAW requiring immobilization will include the LAW separated from the tank waste, as well as new wastes generated by the retrieval, pretreatment, and immobilization processes. Per the Tri-Party Agreement (1994), both the LAW and HLW will be vitrified. It has been estimated that vitrification of the LAW waste will result in over 500,000 metric tons or 200,000 m 3 of immobilized LAW (ILAW) glass. The ILAW glass is to be disposed of onsite in a near-surface burial facility. It must be demonstrated that the disposal system will adequately retain the radionuclides and prevent contamination of the surrounding environment. This report describes a study of the impacts of systematic glass-composition variation on the responses from accelerated laboratory corrosion tests of representative LAW glasses. A combination of two tests, the product consistency test and vapor-hydration test, is being used to give indictations of the relative rate at which a glass could be expected to corrode in the burial scenario

  20. Capital productivity in industrialised economies: Evidence from error-correction model and lagrange multiplier tests

    Directory of Open Access Journals (Sweden)

    Trofimov Ivan D.

    2017-01-01

    Full Text Available The paper re-examines the “stylized facts” of the balanced growth in developed economies, looking specifically at capital productivity variable. The economic data is obtained from European Commission AMECO database, spanning 1961-2014 period. For a sample of 22 OECD economies, the paper applies univariate LM unit root tests with one or two structural breaks, and estimates error-correction and linear trend models with breaks. It is shown that diverse statistical patterns were present across economies and overall mixed evidence is provided as to the stability of capital productivity and balanced growth in general. Specifically, both upward and downward trends in capital productivity were present, while in several economies mean reversion and random walk patterns were observed. The data and results were largely in line with major theoretical explanations pertaining to capital productivity. With regard to determinants of the capital productivity movements, the structure of capital stock and the prices of capital goods were likely most salient.

  1. Tests on the release of fission and activation products during core meltdown

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, H; Krause, W; Wild, H

    1976-01-01

    The first available results are related to tests in which the release of the main components of the core melt, namely the steel, zircaloy and uranium components, was determined using ThO/sub 2/ crucibles. The release products are dispersed onto the pipe walls of the transport system and the measuring filters which were installed at about 1 m distance from the melt crucibles. Of these, only the precipitates on the filters have been analyzed so far. In the tests under air, the release was clearly dependent on the maximum temperature reached. The release values for Mo and Mn were the highest with 5-10%; uranium with 0.1% on the other hand, was the lowest. In a steam atmosphere over the melt, the analysis of the filter precipitates for all elements gave considerably lower values than with the tests in air.

  2. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    CERN Document Server

    Jentzsch, J; The ATLAS collaboration

    2012-01-01

    For the first ATLAS pixel upgrade scheduled in 2013 a new front-end chip generation (FE- I4) has been developed. The second version (FE-I4B) hosting two different solid-state sensor technologies (planar silicon and 3D silicon) has been produced to be built into a new pixel layer (the Insertable B-Layer, IBL). Prototypes of these assembled modules have been tested in laboratory and testbeam measurements before and after irradiation. Quality assurance measurements under clean room conditions, including temperature and humidity control, have been and will be performed on the required parts during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and also assembled subsystems. Test results of measurements on flexes, modules and staves will be presented.

  3. Nuclear waste glass product consistency test (PCT), Version 5.0

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.; Waters, B.J.

    1992-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Preliminary Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Produce Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 5.0 of the PCT procedure is attached

  4. Initial Flight Test of the Production Support Flight Control Computers at NASA Dryden Flight Research Center

    Science.gov (United States)

    Carter, John; Stephenson, Mark

    1999-01-01

    The NASA Dryden Flight Research Center has completed the initial flight test of a modified set of F/A-18 flight control computers that gives the aircraft a research control law capability. The production support flight control computers (PSFCC) provide an increased capability for flight research in the control law, handling qualities, and flight systems areas. The PSFCC feature a research flight control processor that is "piggybacked" onto the baseline F/A-18 flight control system. This research processor allows for pilot selection of research control law operation in flight. To validate flight operation, a replication of a standard F/A-18 control law was programmed into the research processor and flight-tested over a limited envelope. This paper provides a brief description of the system, summarizes the initial flight test of the PSFCC, and describes future experiments for the PSFCC.

  5. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1989-01-01

    The Product Consistency Test (PCT) is a glass leach test that was developed at the Savannah River Site (SRS) to routinely confirm the durability of nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a 7 day, crushed glass leach test in deionized water at 90 degree C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2--5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment

  6. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Fission product behavior during the first two PBF severe fuel damage tests

    International Nuclear Information System (INIS)

    Osetek, D.J.; Cronenberg, A.W.; Hobbins, R.R.; Vinjamuri, K.

    1984-01-01

    The results of the first two severe fuel damage tests performed in the Power Burst Facility are assessed in terms of fission product release and chemical behavior. On-line gamma spectroscopy and grab sample data indicate limited release during solid-phase fuel heatup. Analysis indicates that the fuel morphology conditions for the trace-irradiated fuel employed in these two tests limit initial release. Only upon high temperature fuel restructuring and liquefaction is significant release indicated. Chemical equilibrium predictions, based on steam oxidation or reduction conditions, indicate I to be the primary iodine species during trnsport in the steam environment of the first test and CsI to be the primary species during transport in the hydrogen environment of the second test. However, the higher steam flow rate conditions of the first test transported the released iodine through the sample system; whereas, low-hydrogen flow rate of the second test apparently allowed the vast majority of iodine-bearing compounds to plateout during transport

  8. Optical coherence tomography applied to tests of skin care products in humans--a case study.

    Science.gov (United States)

    Vasquez-Pinto, L M C; Maldonado, E P; Raele, M P; Amaral, M M; de Freitas, A Z

    2015-02-01

    When evaluating skin care products for human skin, quantitative test methods need to be simple, precise and reliable. Optical coherence tomography (OCT), provides high-resolution sectional images of translucent materials to a depth of a few millimeters, a technique usually applied to medical measurements in ophthalmology and dermatology. This study aimed to demonstrate the application of OCT as the main technique for monitoring changes in skin topography during tests of a wrinkle-reduction product in humans. We used a commercial OCT apparatus to perform clinical examinations of skin roughness in treated and non-treated sites in the periorbital region of thirty human voluntaries who were using an anti-aging product commercially available: Natura Chronos® Flavonóides de Passiflora 45+ FPS15, from Natura Cosméticos, Brazil. Measurements were performed days 0, 7, 14 and 28 of treatment. Equipment and software allowed real-time recording of skin roughness parameters and wrinkle depths. The OCT measurements have allowed the monitoring of changes in skin roughness, which have shown reduction in treated sites around 10%. The obtained depth distributions also indicate reduction in the occurrence of wrinkles deeper than 170 μm. The verified results are consistent with those typically obtained after successful treatment with modern anti-aging products. By using the OCT technique, it was possible to quantify changes in skin roughness and in the distribution of depths of skin wrinkles, with adequate sensitivity. OCT imaging allows the direct visualization of the skin topography with resolution of micrometers, a reliable and interactive tool for clinical use. Therefore, for the first time, we demonstrated the use of OCT technique to verify the efficacy of cosmetic products in real time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Development of an in vitro skin sensitization test based on ROS production in THP-1 cells.

    Science.gov (United States)

    Saito, Kazutoshi; Miyazawa, Masaaki; Nukada, Yuko; Sakaguchi, Hitoshi; Nishiyama, Naohiro

    2013-03-01

    Recently, it has been reported that reactive oxygen species (ROS) produced by contact allergens can affect dendritic cell migration and contact hypersensitivity. The aim of the present study was to develop a new in vitro assay that could predict the skin sensitizing potential of chemicals by measuring ROS production in THP-1 (human monocytic leukemia cell line) cells. THP-1 cells were pre-loaded with a ROS sensitive fluorescent dye, 5-(and 6-)-chloromethyl-2', 7'-dichlorodihydrofluorescein diacetate, acetyl ester (CM-H2DCFDA), for 15min, then incubated with test chemicals for 30min. The fluorescence intensity was measured by flow cytometry. For the skin sensitizers, 25 out of 30 induced over a 2-fold ROS production at more than 90% of cell viability. In contrast, increases were only seen in 4 out of 20 non-sensitizers. The overall accuracy for the local lymph node assay (LLNA) was 82% for 50 chemicals tested. A correlation was found between the estimated concentration showing 2-fold ROS production in the ROS assay and the EC3 values (estimated concentration required to induce positive response) of the LLNA. These results indicated that the THP-1 cell-based ROS assay was a rapid and highly sensitive detection system able to predict skin sensitizing potentials and potency of chemicals. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility

    International Nuclear Information System (INIS)

    Beek, E.J.R. van; Schmiedeskamp, J.; Filbir, F.; Heil, W.; Wolf, M.; Otten, E.; Wild, J.M.; Paley, M.N.J.; Fichele, S.; Woodhouse, N.; Swift, A.; Knitz, F.; Mills, G.H.

    2003-01-01

    The aim of this study was to test the feasibility of a central production facility with distribution network for implementation of hyperpolarized 3-helium MRI. The 3-helium was hyperpolarized to 50-65% using a large-scale production facility based at a university in Germany. Using a specially designed transport box, containing a permanent low-field shielded magnet and dedicated iron-free glass cells, the hyperpolarized 3-helium gas was transported via airfreight to a university in the UK. At this location, the gas was used to perform in vivo MR experiments in normal volunteers and patients with chronic obstructive lung diseases. Following initial tests, the transport (road-air-road cargo) was successfully arranged on six occasions (approximately once per month). The duration of transport to imaging averaged 18 h (range 16-20 h), which was due mainly to organizational issues such as working times and flight connections. During the course of the project, polarization at imaging increased from 20% to more than 30%. A total of 4 healthy volunteers and 8 patients with chronic obstructive pulmonary disease were imaged. The feasibility of a central production facility for hyperpolarized 3-helium was demonstrated. This should enable a wider distribution of gas for this novel technology without the need for local start-up costs. (orig.)

  11. Production integrated nondestructive testing of composite materials and material compounds - an overview

    Science.gov (United States)

    Straß, B.; Conrad, C.; Wolter, B.

    2017-03-01

    Composite materials and material compounds are of increasing importance, because of the steadily rising relevance of resource saving lightweight constructions. Quality assurance with appropriate Nondestructive Testing (NDT) methods is a key aspect for reliable and efficient production. Quality changes have to be detected already in the manufacturing flow in order to take adequate corrective actions. For materials and compounds the classical NDT methods for defectoscopy, like X-ray and Ultrasound (US) are still predominant. Nevertheless, meanwhile fast, contactless NDT methods, like air-borne ultrasound, dynamic thermography and special Eddy-Current techniques are available in order to detect cracks, voids, pores and delaminations but also for characterizing fiber content, distribution and alignment. In Metal-Matrix Composites US back-scattering can be used for this purpose. US run-time measurements allow the detection of thermal stresses at the metal-matrix interface. Another important area is the necessity for NDT in joining. To achieve an optimum material utilization and product safety as well as the best possible production efficiency, there is a need for NDT methods for in-line inspection of the joint quality while joining or immediately afterwards. For this purpose EMAT (Electromagnetic Acoustic Transducer) technique or Acoustic Emission testing can be used.

  12. 77 FR 21065 - Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth Group of...

    Science.gov (United States)

    2012-04-09

    ... 2070-AJ66 Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth... an opportunity to comment on a proposed test rule for 23 high production volume (HPV) chemical... necessary, to prohibit or limit that activity before it occurs. The opportunity to present oral comment was...

  13. Predicament in detection and reporting of extended spectrum beta lactamase production in routine antibiotic susceptibility testing

    International Nuclear Information System (INIS)

    Butt, T.; Butt, E.; Raza, S.

    2017-01-01

    This descriptive and cross-sectional study was planned to determine the dilemma of inadvertent detection of extended spectrum beta lactamase (ESBL) production in Enterobacteriaceaewhen using inhibition zone size of antibiotic disks of Cefotaxime or Aztreonam in routine antibiotic susceptibility testing as recommended by Clinical Laboratory Standards Institute (CLSI). Screening and double disk tests were adopted as per CLSI. Escherichia coli ATCC 25922 was used as control strain. Among total specimens of 5346, there were 348 isolates of Escherichia coli(n=235), Klebsiella pneumonia (n=92), Klebsiella oxytoca(n=3) or Proteus mirabilus(n=18). The screening method recommended by CLSI significantly falsely detected ESBL production in 79 (32.3%) isolates (p<0.0001). ESBL detection is important as its frequency is high and treatment of the infection varies with the presence and absence of ESBL. To avoid false reporting, proper phenotypic detection of ESBL confirmatory method-like double-disk synergy test, should be used routinely. (author)

  14. Protocol for production of a chewable material for masticatory function tests (Optocal - Brazilian version

    Directory of Open Access Journals (Sweden)

    Rafael de Liz Pocztaruk

    2008-12-01

    Full Text Available The present article aimed to present a standardized protocol for the production of a chewable test material that has been used in masticatory efficiency and performance studies. This chewable material has advantages in respect to its physical properties when compared to other artificial and natural test foods. It is constituted by mixing condensation silicon (58.3% by weight, common plaster (10.2% by weight, alginate (12.5% by weight, solid vaseline (11.5% by weight, tooth paste (7.5% by weight, and catalyst paste (20.8 mg/g, adding also three drops of mint essence. The mixed material is then inserted into an acrylic mould with perforations of 12 mm in diameter and 5 mm in height to produce rounded tablets with those measures after polymerization. It was named "Optocal - Brazilian version". A volume of 3 cm³ is indicated for a chewing test, which corresponds to 12 tablets using the present methodology. The present protocol can make the production of this chewable material easier, helping in its standardization for studies on masticatory function.

  15. Testing Open-Air Storage of Stumps to Provide Clean Biomass for Energy Production

    Directory of Open Access Journals (Sweden)

    Luigi Pari

    2017-10-01

    Full Text Available When orchards reach the end of the productive cycle, the stumps removal becomes a mandatory operation to allow new soil preparation and to establish new cultivations. The exploitation of the removed stump biomass seems a valuable option, especially in the growing energy market of the biofuels; however, the scarce quality of the material obtained after the extraction compromises its marketability, making this product a costly waste to be disposed. In this regard, the identification of affordable strategies for the extraction and the cleaning of the material will be crucial in order to provide to plantation owners the chance to sell the biomass and offset the extraction costs. Mechanical extraction and cleaning technologies have been already tested on forest stumps, but these systems work on the singular piece and would be inefficient in the conditions of an intensive orchard, where stumps are small and numerous. The objective of this study was to test the possibility to exploit a natural stumps cleaning system through open-air storage. The tested stumps were obtained from two different vineyards, extracted with an innovative stump puller specifically designed for continuous stump removal in intensively-planted orchards. The effects of weathering were evaluated to determine the fuel quality immediately after the extraction and after a storage period of six months with respect to moisture content, ash content, and heating value. Results indicated interesting storage performance, showing also different dynamics depending on the stumps utilized.

  16. HANDBOOK - Environmental Assessment of Construction Products - An introduction to test mehtods and other procedures related to CE-marking

    DEFF Research Database (Denmark)

    Wahlstrom, Margareta; Laine-Ylyjoki, Jutta; Rautiainen, Liisa

    2009-01-01

    regulatory limit values with test results. The starting point in this handbook is the situation where there might be a potential for a release to soil and water during the intended use of a product. This handbook presents aspects that are especially important for manufactures of construction products...... Harmonised Standards and European Technical Approvals describe methods for testing of construction products and specify the conditions for CE marking of construction products. This handbook presents an overview of the technical, regulatory and administrative framework within which CE marking of construction...... products takes place and offers guidance on the selection of test methods for assessment of release of regulated dangerous substances from construction products to soil, surface water and groundwater. The handbook includes information on how test results can be used, e.g. by regulators when comparing...

  17. 75 FR 72944 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-11-29

    ...: Revisions to Terms of Acceptance of Children's Product Certifications Based on Third Party Conformity... under which it will accept certifications for children's products based on third party conformity..., requires that certification be based on testing of sufficient samples of the product, or samples that are...

  18. Effects of the DGAT1 polymorphism on test-day milk production traits throughout lactation

    DEFF Research Database (Denmark)

    Bovenhuis, Henk; Visker, H P W; van Valenberg, H J F

    2015-01-01

    Several studies have shown that the diacylglycerol O-acyltransferase 1 (DGAT1) K232A polymorphism has a major effect on milk production traits. It is less clear how effects of DGAT1 on milk production traits change throughout lactation, if dominance effects of DGAT1 are relevant, and whether DGAT1...... also affects lactose content, lactose yield, and total energy output in milk. Results from this study, using test-day records of 3 subsequent parities of around 1,800 cows, confirm previously reported effects of the DGAT1 polymorphism on milk, fat, and protein yield, as well as fat and protein content....... In addition, we found significant effects of the DGAT1 polymorphism on lactose content and lactose yield. No significant effects on somatic cell score were detected. The effect of DGAT1 on total energy excreted in milk was only significant in parity 1 and is mainly due to a higher energy output in milk...

  19. Development of an agricultural biotechnology crop product: testing from discovery to commercialization.

    Science.gov (United States)

    Privalle, Laura S; Chen, Jingwen; Clapper, Gina; Hunst, Penny; Spiegelhalter, Frank; Zhong, Cathy X

    2012-10-17

    "Genetically modified" (GM) or "biotech" crops have been the most rapidly adopted agricultural technology in recent years. The development of a GM crop encompasses trait identification, gene isolation, plant cell transformation, plant regeneration, efficacy evaluation, commercial event identification, safety evaluation, and finally commercial authorization. This is a lengthy, complex, and resource-intensive process. Crops produced through biotechnology are the most highly studied food or food component consumed. Before commercialization, these products are shown to be as safe as conventional crops with respect to feed, food, and the environment. This paper describes this global process and the various analytical tests that must accompany the product during the course of development, throughout its market life, and beyond.

  20. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1990-01-01

    The product consistency test (PCT) is a glass leach test developed at the Savannah River Site (SRS) to confirm the durability of radioactive nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a seven day, crushed glass leach test in deionized water at 90C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2-5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment. When the results of the two laboratories were compared to each other, the agreement was within 20%. Normalized concentrations for the nonradioactive and radioactive elements in the PCT leachates measured at both facilities indicated that the radionuclides were released from the glass slower than the major soluble elements in the glass. For both laboratories, the normalized releases for both glasses were in the general order Li ∼ B ∼ Na > Si > Cs - 137 > Sb - 125 < Sr - 90. The normalized releases for the major soluble elements and the final pH values in the tests with radioactive glass are consistent with those for nonradioactive glasses with similar compositions. This indicates that there was no significant effect of radiation on the results of the PCT

  1. Kepler Data Validation I: Architecture, Diagnostic Tests, and Data Products for Vetting Transiting Planet Candidates

    Science.gov (United States)

    Twicken, Joseph D.; Catanzarite, Joseph H.; Clarke, Bruce D.; Giroud, Forrest; Jenkins, Jon M.; Klaus, Todd C.; Li, Jie; McCauliff, Sean D.; Seader, Shawn E.; Tennenbaum, Peter; hide

    2018-01-01

    The Kepler Mission was designed to identify and characterize transiting planets in the Kepler Field of View and to determine their occurrence rates. Emphasis was placed on identification of Earth-size planets orbiting in the Habitable Zone of their host stars. Science data were acquired for a period of four years. Long-cadence data with 29.4 min sampling were obtained for approx. 200,000 individual stellar targets in at least one observing quarter in the primary Kepler Mission. Light curves for target stars are extracted in the Kepler Science Data Processing Pipeline, and are searched for transiting planet signatures. A Threshold Crossing Event is generated in the transit search for targets where the transit detection threshold is exceeded and transit consistency checks are satisfied. These targets are subjected to further scrutiny in the Data Validation (DV) component of the Pipeline. Transiting planet candidates are characterized in DV, and light curves are searched for additional planets after transit signatures are modeled and removed. A suite of diagnostic tests is performed on all candidates to aid in discrimination between genuine transiting planets and instrumental or astrophysical false positives. Data products are generated per target and planet candidate to document and display transiting planet model fit and diagnostic test results. These products are exported to the Exoplanet Archive at the NASA Exoplanet Science Institute, and are available to the community. We describe the DV architecture and diagnostic tests, and provide a brief overview of the data products. Transiting planet modeling and the search for multiple planets on individual targets are described in a companion paper. The final revision of the Kepler Pipeline code base is available to the general public through GitHub. The Kepler Pipeline has also been modified to support the Transiting Exoplanet Survey Satellite (TESS) Mission which is expected to commence in 2018.

  2. Kepler Data Validation I—Architecture, Diagnostic Tests, and Data Products for Vetting Transiting Planet Candidates

    Science.gov (United States)

    Twicken, Joseph D.; Catanzarite, Joseph H.; Clarke, Bruce D.; Girouard, Forrest; Jenkins, Jon M.; Klaus, Todd C.; Li, Jie; McCauliff, Sean D.; Seader, Shawn E.; Tenenbaum, Peter; Wohler, Bill; Bryson, Stephen T.; Burke, Christopher J.; Caldwell, Douglas A.; Haas, Michael R.; Henze, Christopher E.; Sanderfer, Dwight T.

    2018-06-01

    The Kepler Mission was designed to identify and characterize transiting planets in the Kepler Field of View and to determine their occurrence rates. Emphasis was placed on identification of Earth-size planets orbiting in the Habitable Zone of their host stars. Science data were acquired for a period of four years. Long-cadence data with 29.4 min sampling were obtained for ∼200,000 individual stellar targets in at least one observing quarter in the primary Kepler Mission. Light curves for target stars are extracted in the Kepler Science Data Processing Pipeline, and are searched for transiting planet signatures. A Threshold Crossing Event is generated in the transit search for targets where the transit detection threshold is exceeded and transit consistency checks are satisfied. These targets are subjected to further scrutiny in the Data Validation (DV) component of the Pipeline. Transiting planet candidates are characterized in DV, and light curves are searched for additional planets after transit signatures are modeled and removed. A suite of diagnostic tests is performed on all candidates to aid in discrimination between genuine transiting planets and instrumental or astrophysical false positives. Data products are generated per target and planet candidate to document and display transiting planet model fit and diagnostic test results. These products are exported to the Exoplanet Archive at the NASA Exoplanet Science Institute, and are available to the community. We describe the DV architecture and diagnostic tests, and provide a brief overview of the data products. Transiting planet modeling and the search for multiple planets on individual targets are described in a companion paper. The final revision of the Kepler Pipeline code base is available to the general public through GitHub. The Kepler Pipeline has also been modified to support the Transiting Exoplanet Survey Satellite (TESS) Mission which is expected to commence in 2018.

  3. Generating and testing methods for consumer-oriented product development; Genererende en toetsingsmethoden voor consumentgerichte productontwikkeling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process. [Dutch] Om een goed inzicht te krijgen in verschillende ontwerpmethoden die productontwikkelaars kunnen gebruiken om bruikbare domoticaproducten te kunnen ontwikkelen en toetsen, is een inventarisatie uitgevoerd naar de methoden die in Nederland worden gebruikt. De inventarisatie richt zich op twee categorieen methoden: (1) methoden om de gebruiker casu quo het probleem beter te leren kennen en nieuwe oplossingen te genereren, zogenaamde genererende methoden, en (2) methoden om oplossingen te evatueren (in verschillende fasen van het ontwerpproces), zogenaamde toetsingsmethoden. De eerste categorie methoden richt zich op het ontwerpproces: hoe kan de ontwerper tijdens het ontwerpproces de bruikbaarheid van (domotica)producten zoveel mogelijk realiseren? De tweede categorie methoden is erop gericht om een ontwerp (in wat voor vorm dan ook: tekening, prototype, functionele computeranimatie, enzovoort) te toetsen bij gebruikers. Het zijn methoden om een ontwerp, op verschillende momenten

  4. Regularities of in-regional redistribution of the nuclear test products in the atmosphere

    International Nuclear Information System (INIS)

    Tsitskishvili, M.S.; Chkhartishvili, A.G.; Nozadze, M.R.; Intskirveli, L.N.; Buachidze, N.D.; Churguliya, E.R.; Shatberashvili, I.G.; Diasamidze, R.I.; Karchava, G.V.; Gugushvili, B.S.

    2003-01-01

    Regularities of artificial radionuclides redistribution in the Caucasus atmosphere are studied. The structure of global fallout in the region is considered. It is noted, that Caucasus is characterizing by a wide diversity of the landscapes and soils. This diversity results a different migration regime for radioisotopes in soils. Penetration of the nuclear tests products into the soils depends on the annual precipitation amount (soil humidification), and incoming level of the radioisotopes. At evaluation of external and internal irradiation doses on South Caucasus population the Caucasus was divided into regions by levels of the global reactive fallout

  5. Processing of LEU targets for 99Mo production--testing and modification of the Cintichem process

    International Nuclear Information System (INIS)

    Wu, D.; Landsberger, S.; Buchholz, B.

    1995-09-01

    Recent experimental results on testing and modification of the Cintichem process to allow substitution of low enriched uranium (LEU) for high enriched uranium (HEU) targets are presented in this report. The main focus is on 99 Mo recovery and purification by its precipitation with α-benzoin oxime. Parameters that were studied include concentrations of nitric and sulfuric acids, partial neutralization of the acids, molybdenum and uranium concentrations, and the ratio of α-benzoin oxime to molybdenum. Decontamination factors for uranium, neptunium, and various fission products were measured. Experiments with tracer levels of irradiated LEU were conducted for testing the 99 Mo recovery and purification during each step of the Cintichem process. Improving the process with additional processing steps was also attempted. The results indicate that the conversion of molybdenum chemical processing from HEU to LEU targets is possible

  6. GLASS FABRICATION AND PRODUCT CONSISTENCY TESTING OF LANTHANIDE BOROSILICATE FRIT X COMPOSITION FOR PLUTONIUM DISPOSITION

    Energy Technology Data Exchange (ETDEWEB)

    Marra, J

    2006-11-15

    The Department of Energy Office of Environmental Management (DOE/EM) plans to conduct the Plutonium Disposition Project at the Savannah River Site (SRS) to disposition excess weapons-usable plutonium. A plutonium glass waste form is the preferred option for immobilization of the plutonium for subsequent disposition in a geologic repository. A reference glass composition (Lanthanide Borosilicate (LaBS) Frit B) was developed during the Plutonium Immobilization Program (PIP) to immobilize plutonium in the late 1990's. A limited amount of performance testing was performed on this baseline composition before efforts to further pursue Pu disposition via a glass waste form ceased. Recent FY05 studies have further investigated the LaBS Frit B formulation as well as development of a newer LaBS formulation denoted as LaBS Frit X. The objectives of this present task were to fabricate plutonium loaded LaBS Frit X glass and perform corrosion testing to provide near-term data that will increase confidence that LaBS glass product is suitable for disposal in the Yucca Mountain Repository. Specifically, testing was conducted in an effort to provide data to Yucca Mountain Project (YMP) personnel for use in performance assessment calculations. Plutonium containing LaBS glass with the Frit X composition with a 9.5 wt% PuO{sub 2} loading was prepared for testing. Glass was prepared to support Product Consistency Testing (PCT) at Savannah River National Laboratory (SRNL). The glass was thoroughly characterized using x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS) prior to performance testing. A series of PCTs were conducted at SRNL using quenched Pu Frit X glass with varying exposed surface areas. Effects of isothermal and can-in-canister heat treatments on the Pu Frit X glass were also investigated. Another series of PCTs were performed on these different heat-treated Pu Frit X glasses. Leachates from all these PCTs

  7. Drilling and Production Testing the Methane Hydrate Resource Potential Associated with the Barrow Gas Fields

    Energy Technology Data Exchange (ETDEWEB)

    Steve McRae; Thomas Walsh; Michael Dunn; Michael Cook

    2010-02-22

    In November of 2008, the Department of Energy (DOE) and the North Slope Borough (NSB) committed funding to develop a drilling plan to test the presence of hydrates in the producing formation of at least one of the Barrow Gas Fields, and to develop a production surveillance plan to monitor the behavior of hydrates as dissociation occurs. This drilling and surveillance plan was supported by earlier studies in Phase 1 of the project, including hydrate stability zone modeling, material balance modeling, and full-field history-matched reservoir simulation, all of which support the presence of methane hydrate in association with the Barrow Gas Fields. This Phase 2 of the project, conducted over the past twelve months focused on selecting an optimal location for a hydrate test well; design of a logistics, drilling, completion and testing plan; and estimating costs for the activities. As originally proposed, the project was anticipated to benefit from industry activity in northwest Alaska, with opportunities to share equipment, personnel, services and mobilization and demobilization costs with one of the then-active exploration operators. The activity level dropped off, and this benefit evaporated, although plans for drilling of development wells in the BGF's matured, offering significant synergies and cost savings over a remote stand-alone drilling project. An optimal well location was chosen at the East Barrow No.18 well pad, and a vertical pilot/monitoring well and horizontal production test/surveillance well were engineered for drilling from this location. Both wells were designed with Distributed Temperature Survey (DTS) apparatus for monitoring of the hydrate-free gas interface. Once project scope was developed, a procurement process was implemented to engage the necessary service and equipment providers, and finalize project cost estimates. Based on cost proposals from vendors, total project estimated cost is $17.88 million dollars, inclusive of design work

  8. Simulating the gas hydrate production test at Mallik using the pilot scale pressure reservoir LARS

    Science.gov (United States)

    Heeschen, Katja; Spangenberg, Erik; Schicks, Judith M.; Priegnitz, Mike; Giese, Ronny; Luzi-Helbing, Manja

    2014-05-01

    LARS, the LArge Reservoir Simulator, allows for one of the few pilot scale simulations of gas hydrate formation and dissociation under controlled conditions with a high resolution sensor network to enable the detection of spatial variations. It was designed and built within the German project SUGAR (submarine gas hydrate reservoirs) for sediment samples with a diameter of 0.45 m and a length of 1.3 m. During the project, LARS already served for a number of experiments simulating the production of gas from hydrate-bearing sediments using thermal stimulation and/or depressurization. The latest test simulated the methane production test from gas hydrate-bearing sediments at the Mallik test site, Canada, in 2008 (Uddin et al., 2011). Thus, the starting conditions of 11.5 MPa and 11°C and environmental parameters were set to fit the Mallik test site. The experimental gas hydrate saturation of 90% of the total pore volume (70 l) was slightly higher than volumes found in gas hydrate-bearing formations in the field (70 - 80%). However, the resulting permeability of a few millidarcy was comparable. The depressurization driven gas production at Mallik was conducted in three steps at 7.0 MPa - 5.0 MPa - 4.2 MPa all of which were used in the laboratory experiments. In the lab the pressure was controlled using a back pressure regulator while the confining pressure was stable. All but one of the 12 temperature sensors showed a rapid decrease in temperature throughout the sediment sample, which accompanied the pressure changes as a result of gas hydrate dissociation. During step 1 and 2 they continued up to the point where gas hydrate stability was regained. The pressure decreases and gas hydrate dissociation led to highly variable two phase fluid flow throughout the duration of the simulated production test. The flow rates were measured continuously (gas) and discontinuously (liquid), respectively. Next to being discussed here, both rates were used to verify a model of gas

  9. Product consistency testing of three reference glasses in stainless steel and perfluoroalkoxy resin vessels

    International Nuclear Information System (INIS)

    Olson, K.M.; Smith, G.L.; Marschman, S.C.

    1995-03-01

    Because of their chemical durability, silicate glasses have been proposed and researched since the mid-1950s as a medium for incorporating high-level radioactive waste (HLW) generated from processing of nuclear materials. A number of different waste forms were evaluated and ranked in the early 1980s; durability (leach resistance) was the highest weighted factor. Borosilicate glass was rated the best waste form available for incorporation of HLW. Four different types of vessels and three different glasses were used to study the possible effect of vessel composition on durability test results from the Production Consistency Test (PCT). The vessels were 45-m 304 stainless steel vessels, 150-m 304 L stainless steel vessels, and 60-m perfluoroalkoxy (PFA) fluoropolymer resin vessels. The three glasses were the Environmental Assessment glass manufactured by Corning Incorporated and supplied by Westinghouse Savannah River company, and West Valley Nuclear Services reference glasses 5 and 6, manufactured and supplied by Catholic University of America. Within experimental error, no differences were found in durability test results using the 3 different glasses in the 304L stainless steel or PFA fluoropolymer resin vessels over the seven-day test period

  10. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 2)].

    Science.gov (United States)

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Yamada, Kyohei; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.

  11. Characterization of currently marketed heparin products: key tests for quality assurance.

    Science.gov (United States)

    Keire, David A; Ye, Hongping; Trehy, Michael L; Ye, Wei; Kolinski, Richard E; Westenberger, Benjamin J; Buhse, Lucinda F; Nasr, Moheb; Al-Hakim, Ali

    2011-01-01

    During the 2007-2008 heparin crisis, it was found that the United States Pharmacopeia (USP) testing monograph for unfractionated heparin sodium (UFH) did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS) in heparin. In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to not only detect the contaminant OSCS but also to improve assurance of quality and purity of the drug product. Additional tests were also developed to monitor the heparin supply chain for other possible economically motivated additives or impurities. In 2009, a new USP monograph was put in place that includes 500 MHz (1)H NMR, SAX-HPLC, %galactosamine in total hexosamine, and anticoagulation time assays with purified factor IIa or factor Xa. These tests represent orthogonal approaches for UFH identification, measurement of bioactivity, and for detection of process impurities or contaminants in UFH. The FDA has applied these analytical approaches to the study of UFH active pharmaceutical ingredients in the marketplace. Here, we describe results from a comprehensive survey of UFH collected from seven different sources after the 2009 monograph revision and compare these data with results obtained on other heparin samples collected during the 2007-2008 crisis.

  12. Comparing the co-evolution of production and test code in open source and industrial developer test processes through repository mining

    NARCIS (Netherlands)

    Van Rompaey, B.; Zaidman, A.E.; Van Deursen, A.; Demeyer, S.

    2008-01-01

    This paper represents an extension to our previous work: Mining software repositories to study coevolution of production & test code. Proceedings of the International Conference on Software Testing, Verification, and Validation (ICST), IEEE Computer Society, 2008; doi:10.1109/ICST.2008.47

  13. DEVELOPMENT AND TESTING OF UNDERBALANCED DRILLING PRODUCTS. Final Report, Oct 1995 - July 2001

    Energy Technology Data Exchange (ETDEWEB)

    William C. Maurer; William J. McDonald; Thomas E. Williams; John H. Cohen

    2001-07-01

    Underbalanced drilling is experiencing growth at a rate that rivals that of horizontal drilling in the mid-1980s and coiled-tubing drilling in the 1990s. Problems remain, however, for applying underbalanced drilling in a wider range of geological settings and drilling environments. This report addresses developments under this DOE project to develop products aimed at overcoming these problems. During Phase I of the DOE project, market analyses showed that up to 12,000 wells per year (i.e., 30% of all wells) will be drilled underbalanced in the U.S.A. within the next ten years. A user-friendly foam fluid hydraulics model (FOAM) was developed for a PC Windows environment during Phase I. FOAM predicts circulating pressures and flow characteristics of foam fluids used in underbalanced drilling operations. FOAM is based on the best available mathematical models, and was validated through comparison to existing models, laboratory test data and field data. This model does not handle two-phase flow or air and mist drilling where the foam quality is above 0.97. This FOAM model was greatly expanded during Phase II including adding an improved foam rheological model and a ''matching'' feature that allows the model to be field calibrated. During Phase I, a lightweight drilling fluid was developed that uses hollow glass spheres (HGS) to reduce the density of the mud to less than that of water. HGS fluids have several advantages over aerated fluids, including they are incompressible, they reduce corrosion and vibration problems, they allow the use of mud-pulse MWD tools, and they eliminate high compressor and nitrogen costs. Phase II tests showed that HGS significantly reduce formation damage with water-based drilling and completion fluids and thereby potentially can increase oil and gas production in wells drilled with water-based fluids. Extensive rheological testing was conducted with HGS drilling and completion fluids during Phase II. These tests showed

  14. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  15. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH{sub 4} + H{sub 2}O {yields} 3H{sub 2}O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m{sup 3}{sub N}/h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  16. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH 4 + H 2 O → 3H 2 O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m 3 N /h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  17. Use of hot set and gel content test in QA/QC for irradiation of commercial products

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Siti Aiasah Hashim; Zulkafli Ghazali; Zarina Mohd Noor

    2006-01-01

    Currently, irradiation of polyolefin heat shrinkable tube is the main commercial activity at Alurtron. Other products include medical devices and cosmetic products. As required by the quality management system, ISO 9001:2000, Alurtron is responsible to ensure that customer received their irradiation dose as requested. At present two test methods are employed namely, hot set and gel content measurement to verify received dose . Hot set test is a physical test to determine longitudinal shrinkage of the irradiated products. Whereas gel content measurement determine to certain extend the degree of crosslinking occurred in polymeric material upon irradiation, in the customer products. Both test are routinely used to cross-check the dose required by customer. This paper outlines the correlation between hot set and gel content measurement of customer products. (Author)

  18. Lignin development tests. Announcement I. Characteristics of celluloselignin derived in production of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Rozmarin, Ch.; Popa, V.I.

    1982-01-01

    During production of furfural from waste agricultural plants, a large quantity of cellulose-lignin is left (CL). Provides analysis results on tests carried out to determine potential chemical application of this complex product. In particular, it was shown that in corncobs and in sunflower seed husks, the following components are present, respectively (%): difficult to hydrolize polysaccharides 42.8 and 20.3, easily hydrolized 38.2 and 27.9; lignin 20.3 and 26.55; acids: galacturonic 7 and 5.5, glycuronic 9 and 7; monosaccharides: galactose 7 and 5.5, glycose - traces and 7, arabinose 10.8 and 8.4, xylose 45 and 40, ramnose 9 and 9. CL derived during production of furfural, contains (%): ash 6.47, difficult to hydrolize polysaccharides 37.25, residual lignin after hydrolysis with 80% H/sub 2/SO/sub 4/ 57.5, PB in cold water extract 9.05, -OCH/sub 3/ 5.02, -OH 33.1, acids extracted with cold water, 5.32. Composition of lignin extracted with cold water from CL (%): C-60.58, H-5.03, 0-34.39, ash 0.58, -OCH/sub 3/, 5.51, OH 13.96. The given date make it possible to conclude that CL has a complex composition which must be taken in account when selecting its utilization.

  19. A data base and a standard material for use in acceptance testing of low-activity waste products

    International Nuclear Information System (INIS)

    Wolf, S.F.; Ebert, W.L.; Luo, J.S.; Strachan, D.M.

    1998-04-01

    The authors have conducted replicate dissolution tests following the product consistency test (PCT) procedure to measure the mean and standard deviation of the solution concentrations of B, Na, and Si at various combinations of temperature, duration, and glass/water mass ratio. Tests were conducted with a glass formulated to be compositionally similar to low-activity waste products anticipated for Hanford to evaluate the adequacy of test methods that have been designated in privatization contracts for use in product acceptance. An important finding from this set of tests is that the solution concentrations generated in tests at 20 C will likely be too low to measure the dissolution rates of waste products reliably. Based on these results, the authors recommend that the acceptance test be conducted at 40 C. Tests at 40 C generated higher solution concentrations, were more easily conducted, and the measured rates were easily related to those at 20 C. Replicate measurements of other glass properties were made to evaluate the possible use of LRM-1 as a standard material. These include its composition, homogeneity, density, compressive strength, the Na leachability index with the ANSI/ANS 16.1 leach test, and if the glass is characteristically hazardous with the toxicity characteristic leach procedure. The values of these properties were within the acceptable limits identified for Hanford low-activity waste products. The reproducibility of replicate tests and analyses indicates that the glass would be a suitable standard material

  20. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  1. Complex evaluation of ecology situation and soil productivity of Semipalatinsk nuclear test site, perspectives of use

    International Nuclear Information System (INIS)

    Lebed', L.; Ptiskaya, L.; Lyashenko; Pisak, R.

    1996-01-01

    Objective of the Project. The goal of the project is complex evaluation of environmental resources at the former Semipalatinsk Test Site and perspectives of their cultivation with taking into account radioactive pollution. Scope of Activities. The following main works at the territory of the former Semipalatinsk Test Site: - estimate of climate, climatic resources and their changes; - organization and realization of complex visual and tool-making air survey (geo botanical, utter satellite spectrometric, radiometric); - reception and computer treatment of space information; - organization and realization of surface expedition field works (radiometric measurements and geo botanical observations); - realization of laboratory analysis for exposure of radio nucleus content in soil, plant and water; - treatment of materials of geo botanical survey, construction of plant and soil maps; - treatment of materials of aero spectrometric and space survey, calculation of vegetation cover productivity, drawing up of computer maps; - assessment of desert and steppe zone vegetation dynamic under artificial and climate impact.Expected Results. The following main investigation results will be obtained first for the territory of Semipalatinsk Test Site and area around it. 1. Objective modern characteristics of radioactive land pollution. Distribution of radio nucleus in soil and vegetation cover. 2. Modern characteristics climatic resources assessment under possible climate change. 3. New maps of vegetation and soil cover, biological and feed productivity of the lands of the polygon at the scale 1:100 000 -1:1 500 000 taking into account climatic resources of the region. 4. Dynamics of desert and steppe zone vegetation assessment under radiation impact and possible climate change. 5. Features of vegetation restoration under constant radiation influence. 6. Basis of perspectives of land cultivation in the Semipalatinsk polygon area and recommendation on rehabilitation soil and

  2. TECHNOLOGICAL TESTS USING QUARTZITE RESIDUES AS COMPONENT OF CERAMIC MASS AT THE PORCELAIN STONEWARE PRODUCTION

    Directory of Open Access Journals (Sweden)

    Marcondes Mendes Souza

    2015-03-01

    Full Text Available This work aims to evaluate through technological tests the use of quartzite residues as component at the the production of porcelain stoneware. Were collected five samples of quartzites called of green quartzite, black quartzite, pink quartzite, goldy quartzite, white quartzite. After, the raw materials were milled, passed by a sieve with a Mesh of 200# (Mesh and characterized by chemical analysis in fluorescence of x-rays and also analysis of the crystalline phases by diffraction of x-rays. The porcelain tiles mass is composed of five formulations containing 57% of feldspar, 37% of clay and 6% of residues of quartzite with different coloration. For the preparation of the specimens, it was used uniaxial pressing, which afterwards were synthesized at 1150°C, 1200°C and 1250°C. After the sintering, the specimens were submit for tests of technological characterization like: water absorption, linear shrinkage, apparently porosity, density and flexural strain at three points. The results presented in the fluorescence of x-rays showed a high-content of iron oxide on black quartzite that is why it was discarded the utilization of it in porcelain stoneware. All quartzite formulations had low water absorption achieved when synthesized at 1200°C, getting 0.1 to 0.36% without having gone through the atomization process. At the tests of flexural strain, all the quartzite had in acceptance limits, according to the European norm EN 100, overcoming 27 MPA at 1200°C

  3. Induction of the acrosome reaction test to in vitro estimate embryo production in Nelore cattle

    Directory of Open Access Journals (Sweden)

    M.Z. Costa

    2010-08-01

    Full Text Available The effectiveness of induction of the acrosome reaction (AR test as a parameter to in vitro estimate embryo production (IVP in Nelore breed and the AR pattern by the Trypan Blue/Giemsa (TB stain were evaluated. Frozen semen samples from ten Nelore bulls were submitted to AR induction and were also evaluated for cleavage and blastocyst rates. The treatments utilized for AR induction were: control (TALP medium, TH (TALP medium + 10μg heparin, TL (TALP medium + 100μg lysophosphatidylcholine and THL (TALP medium + 10μg heparin + 100μg lysophosphatidylcholine. Sperm acrosomal status and viability were evaluated by TB staining at 0 and after 4h incubation at 38°C. The results obtained for AR presented a significant difference (P<0.05 in the percentage of acrosome reacted live sperm after 4h of incubation in the treatments that received heparin. The cleavage and blastocyst rates were 60% and 38% respectively and a significant difference was observed among bulls (P<0.05. It was founded a satisfactory model to estimate the cleavage and blastocyst rates by AR induction test. Therefore, it can be concluded that the induction of the AR test is a valuable tool to predict the IVP in Nelore breed.

  4. Evaluation of Alternative Methods for Testing the Bioefficacy of Household Ambient Insecticide Products Against Aedes albopictus.

    Science.gov (United States)

    Cassini, Rudi; Scremin, Mara; Contiero, Barbara; Drago, Andrea; Vettorato, Christian; Marcer, Federica; di Regalbono, Antonio Frangipane

    2016-06-01

    Ambient insecticides are receiving increasing attention in many developed countries because of their value in reducing mosquito nuisance. As required by the European Union Biocidal Products Regulation 528/2012, these devices require appropriate testing of their efficacy, which is based on estimating the knockdown and mortality rates of free-flying (free) mosquitoes in a test room. However, evaluations using free mosquitoes present many complexities. The performances of 6 alternative methods with mosquitoes held in 2 different cage designs (steel wire and gauze/plastic) with and without an operating fan for air circulation were monitored in a test room through a closed-circuit television system and were compared with the currently recommended method using free mosquitoes. Results for caged mosquitoes without a fan showed a clearly delayed knockdown effect, whereas outcomes for caged mosquitoes with a fan recorded higher mortality at 24 h, compared to free mosquitoes. Among the 6 methods, cages made of gauze and plastic operating with fan wind speed at 2.5-2.8 m/sec was the only method without a significant difference in results for free mosquitoes, and therefore appears as the best alternative to assess knockdown by ambient insecticides accurately.

  5. GLASS FABRICATION AND PRODUCT CONSISTENCY TESTING OF LANTHANIDE BOROSHILICATE FRIT X COMPOSITION FOR PLUTONIUM DISPOSITION

    Energy Technology Data Exchange (ETDEWEB)

    Marra, J

    2006-11-21

    The Department of Energy Office of Environmental Management (DOE/EM) plans to conduct the Plutonium Disposition Project at the Savannah River Site (SRS) to disposition excess weapons-usable plutonium. A plutonium glass waste form is the preferred option for immobilization of the plutonium for subsequent disposition in a geologic repository. A reference glass composition (Lanthanide Borosilicate (LaBS) Frit B) was developed during the Plutonium Immobilization Program (PIP) to immobilize plutonium in the late 1990's. A limited amount of performance testing was performed on this baseline composition before efforts to further pursue Pu disposition via a glass waste form ceased. Recent FY05 studies have further investigated the LaBS Frit B formulation as well as development of a newer LaBS formulation denoted as LaBS Frit X. The objectives of this present task were to fabricate plutonium loaded LaBS Frit X glass and perform corrosion testing to provide near-term data that will increase confidence that LaBS glass product is suitable for disposal in the Yucca Mountain Repository. Specifically, testing was conducted in an effort to provide data to Yucca Mountain Project (YMP) personnel for use in performance assessment calculations. Plutonium containing LaBS glass with the Frit X composition with a 9.5 wt% PuO{sub 2} loading was prepared for testing. Glass was prepared to support Product Consistency Testing (PCT) at Savannah River National Laboratory (SRNL). The glass was thoroughly characterized using x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS) prior to performance testing. A series of PCTs were conducted at SRNL using quenched Pu Frit X glass with varying exposed surface areas. Effects of isothermal and can-in-canister heat treatments on the Pu Frit X glass were also investigated. Another series of PCTs were performed on these different heat-treated Pu Frit X glasses. Leachates from all these PCTs

  6. Corrosion testing on crude oil tankers and other product carriers by means of acoustic emission (AE)

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Gerald [TUV Austria, Deutschstrasse 10, 1230 Wien (Austria); Tscheliesnig, Peter [TUV Austria, Deutschstrasse 10, 1230 Wien (Austria)

    2004-07-01

    In the last decades a lot of maritime disasters with crude oil tankers occurred (e.g. Exxon- Valdez, Erika, Prestige). Every accident led to extreme pollution with horrible consequences not only for the environment but also for the life of the inhabitants of the affected coasts. Although most of these accidents were caused by human errors, the material degradation of the ship hull due to corrosion played an important role. Acoustic emission (AE) is already used to detect and discriminate the stage of corrosion of structures located on land. A consortium consisting of experienced partners from the fields of ship building and classification as well as from AE testing and equipment manufacturing started to investigate the feasibility of this testing technique for its application on oil tankers. The aim of the research project funded by the European Commission is to develop an on-line corrosion monitoring technique based on a permanent installation of AE sensors as well as a spot testing technique during stops in harbors or at anchorages using mobile equipment. Since the project was started, a lot of lab tests as well as background measurements were done on different types of tankers up to a size of 35.000 dead weight tons (DWT). The gathered data were evaluated with a frequency domain based pattern recognition system and it was possible to distinguish the AE signals related to corrosion from those signals, which were emitted by the structure due to the harsh environment on sea (background noise). Together with the oncoming developments of the AE equipment and the improvement of the data base, this project will lead to an important breakthrough for the safe shipping of hazardous products like crude oil. (authors)

  7. Contract for service to produce 50 tonnes sterifeed - lesson learned from semi-commercial scale test production

    International Nuclear Information System (INIS)

    Hassan Hamdani Mutaat; Mat Rasol Awang; Zainon Said; Irwan Md Arif; Alias K Sadeli

    2005-01-01

    A contract for service has been awarded to a local company to produce 50 tonnes Sterifeed in a period of 4 months commencing 3 September 2001. The production was for supplying enough feed for the testing of Sterifeed on cattle. Appointed contractor was required to manage the production, supply labours and provide transport for the full production operation of the plant. The production performance is discussed based on: the labour cost; supervision and control; and skill and training. This report discusses and evaluate the suitability of service for contract for the future commercial scale production. (Author)

  8. Tests of Low Scale Gravity via Gauge Boson Pair Production in γγ Collisions

    International Nuclear Information System (INIS)

    Rizzo, Thomas G.

    1999-01-01

    Arkani-Hamed, Dimopoulos and Dvali have recently proposed that gravity may become strong at energies near 1 TeV thus removing the hierarchy problem. This scenario can be tested in several ways at present and future colliders. In this paper we examine the exchange of towers of Kaluza-Klein gravitons and their influence on the production of pairs of massive gauge bosons in γγ collisions. These tower exchanges are shown to lead to a new dimension-8 operator that can significant alter the Standard Model expectations for these processes. The role of polarization for both the initial state photons and the final state gauge bosons in improving sensitivity to graviton exchange is emphasized. We find that the discovery reach for graviton tower exchange in the γγ r a rrow W + W - channel to be significantly greater than for any other process so far examined

  9. A ring test of a wireless in vitro gas production system

    DEFF Research Database (Denmark)

    Cornou, Cecile; Storm, Ida Marie Lindhardt Drejer; Hindrichsen, Ida Katarina Auf der M.

    2013-01-01

    ) or sheep (SP). Curves, corrected for blanks, were fitted using an exponential regression model with a lag time. The following variables were considered: (i) GP24 and GP48: raw values at 24 and 48 h (mL/g DM), corrected for blanks; (ii) A: asymptotic GP (mL/g DM); (iii) T1/2: time when half A is produced (h......); (iv) GPMR: maximum predicted GP rate (mL/h); (v) L: lag time (h). A mixed model including laboratories as random effect was used. A significant interaction between substrate and laboratories was found for all variables except A. The most repeatable and reproducible results were observed for A and GP48......The in vitro gas production (GP) technique has been widely used for feed evaluation. However, variability in results limits useful comparisons. Results from a ring test undertaken in four laboratories (Italy - IT, Spain - SP, Wales - WA and Denmark - DK) using the same wireless equipment (ANKOM...

  10. Coherent single pion production by antineutrino charged current interactions and test of PCAC

    Science.gov (United States)

    Marage, P.; Aderholz, M.; Allport, P.; Armenise, N.; Baton, J. P.; Berggren, M.; Bertrand, D.; Brisson, V.; Bullock, F. W.; Burkot, W.; Calicchio, M.; Clayton, E. F.; Coghen, T.; Cooper-Sarkar, A. M.; Erriquez, O.; Fitch, P. J.; Gerbier, G.; Guy, J.; Hamisi, F.; Hulth, P. O.; Jones, G. T.; Kasper, P.; Klein, H.; Middleton, R. P.; Miller, D. B.; Mobayyen, M. M.; Morrison, D. R. O.; Natali, S.; Neveu, M.; O'Neale, S. W.; Parker, M. A.; Petiau, P.; Sacton, J.; Sansum, R. A.; Simopoulou, E.; Vallée, C.; Varvell, K.; Vayaki, A.; Venus, W.; Wachsmuth, H.; Wells, J.; Wittek, W.

    1986-06-01

    The cross section for coherent production of a single π- meson in charged current antineutrino interactions on neon nuclei has been measured in BEBC to be (175±25) 10-40 cm2/neon nucleus, averaged over the energy spectrum of the antineutrino wide band beam at the CERN SPS; this corresponds to (0.9±0.1) % of the total charged currentbar v_μ cross section. The distributions of kinematical variables are in agreement with theoretical predictions based on the PCAC hypothesis and the meson dominance model; in particular, the Q 2 dependence is well described by a propagator containing a mass m=(1.35±0.18) GeV. The absolute value of the cross section is also in agreement with the model. This analysis thus provides a test of the PCAC hypothesis in the antineutrino energy range 5 150 GeV.

  11. Coherent single pion production by antineutrino charged current interactions and test of PCAC

    International Nuclear Information System (INIS)

    Marage, P.; Bertrand, D.; Sacton, J.; Aderholz, M.; Wittek, W.; Allport, P.; Wells, J.; Baton, J.P.; Gerbier, G.; Neveu, M.; Clayton, E.F.; Hamisi, F.; Miller, D.B.; Mobayyen, M.M.; Cooper-Sarkar, A.M.; Guy, J.; Kasper, P.; Venus, W.; Klein, H.; Morrison, D.R.O.; Parker, M.A.; Wachsmuth, H.; Simopoulou, E.; Vayaki, A.

    1986-01-01

    The cross section for coherent production of a single π - meson in charged current antineutrino interactions on neon nuclei has been measured in BEBC to be (175+-25) 10 -40 cm 2 /neon nucleus, averaged over the energy spectrum of the antineutrino wide band beam at the CERN SPS; this corresponds to (0.9+-0.1)% of the total charged current anti νsub(μ) cross section. The distributions of kinematical variables are in agreement with theoretical predictions based on the PCAC hypothesis and the meson dominance model; in particular, the Q 2 dependence is well described by a propagator containing a mass m=(1.35+-0.18)GeV. The absolute value of the cross section is also in agreement with the model. This analysis thus provides a test of the PCAC hypothesis in the antineutrino energy range 5-150 GeV. (orig.)

  12. Full-scale testing, production and cost analysis data for the advanced composite stabilizer for Boeing 737 aircraft, volume 2

    Science.gov (United States)

    Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parson, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.

    1982-01-01

    The development, testing, production activities, and associated costs that were required to produce five-and-one-half advanced-composite stabilizer shipsets for Boeing 737 aircraft are defined and discussed.

  13. Pilot-scale grout production test with a simulated low-level waste

    International Nuclear Information System (INIS)

    Fow, C.L.; Mitchell, D.H.; Treat, R.L.; Hymas, C.R.

    1987-05-01

    Plans are underway at the Hanford Site near Richland, Washington, to convert the low-level fraction of radioactive liquid wastes to a grout form for permanent disposal. Grout is a mixture of liquid waste and grout formers, including portland cement, fly ash, and clays. In the plan, the grout slurry is pumped to subsurface concrete vaults on the Hanford Site, where the grout will solidify into large monoliths, thereby immobilizing the waste. A similar disposal concept is being planned at the Savannah River Laboratory site. The underground disposal of grout was conducted at Oak Ridge National Laboratory between 1966 and 1984. Design and construction of grout processing and disposal facilities are underway. The Transportable Grout Facility (TGF), operated by Rockwell Hanford Operations (Rockwell) for the Department of Energy (DOE), is scheduled to grout Phosphate/Sulfate N Reactor Operations Waste (PSW) in FY 1988. Phosphate/Sulfate Waste is a blend of two low-level waste streams generated at Hanford's N Reactor. Other wastes are scheduled to be grouted in subsequent years. Pacific Northwest Laboratory (PNL) is verifying that Hanford grouts can be safely and efficiently processed. To meet this objective, pilot-scale grout process equipment was installed. On July 29 and 30, 1986, PNL conducted a pilot-scale grout production test for Rockwell. During the test, 16,000 gallons of simulated nonradioactive PSW were mixed with grout formers to produce 22,000 gallons of PSW grout. The grout was pumped at a nominal rate of 15 gpm (about 25% of the nominal production rate planned for the TGF) to a lined and covered trench with a capacity of 30,000 gallons. Emplacement of grout in the trench will permit subsequent evaluation of homogeneity of grout in a large monolith. 12 refs., 34 figs., 5 tabs

  14. New X-ray testing methods of aerosol products for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bozydar Knyziak, Adrian, E-mail: a.knyziak@gum.gov.pl; Rzodkiewicz, Witold, E-mail: w.rzodkiewicz@gum.gov.pl; Kaczorowska, Ewa, E-mail: e.kaczorowska@gum.gov.pl; Derlacinski, Michal, E-mail: m.derlacinski@gum.gov.pl

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  15. Development of production technology for bio diesel fuel and feasibility test of bio diesel engine (II)

    Energy Technology Data Exchange (ETDEWEB)

    Na, Y J; Ju, U S; Park, Y C [National Kyung Sang University (Korea, Republic of)

    1996-02-01

    At the beginning of the 21 st century two urgent tasks which our global countries would face with could be the security of the alternative energy source as a preparation against the fossil energy exhaustion and the development of the clean energy source to protect the environment from pollution. The above two problems should be solved together. The bio diesel oil which is made by methylesterfication of bio oil has very low sulfur content than does the diesel oil. Therefore, there is a great possibility to solve the pollution problem caused by the exhaust gas from diesel engine vehicles. So, bio oil has been attracted with attentions as an alternative and clean energy source. Advanced countries began early to develop the bio diesel oil suitable to their respective conditions. Recently their production stage have reached to the commercial level partially. The sudden increase of energy demand followed by a rapid growth of industry and the serious situation about the environmental pollution caused by the exhaust has from diesel engine vehicles occupying 42% of distribution among all vehicles have called attention of our government to consider the importance of alternative and clean energy sources for the future on the national scale. This study is consisted of three main parts; - The development of production technology for bio diesel oil. - The development of the atomization improvement method and nozzle for high viscous vegetable oils. - Feasibility test of bio diesel engine. (author) 119 refs., 52 tabs., 88 figs.

  16. The development of maple technology for materials testing, isotope production, and neutron-beam applications

    International Nuclear Information System (INIS)

    Lidstone, R.F.; Gillespie, G.E.; Lee, A.G.; Bishop, W.E.

    1996-01-01

    AECL has been developing MAPLE technology to meet Canadian and international requirements for high-performance research reactors. MAPLE refers to a family of open-tank-in-pool reactors that employ compact H 2 O-cooled cores within D 2 O vessels to efficiently furnish neutrons to various types of irradiation facilities. The initial focus was on a 10-MW t Canadian facility for radioisotope production, the HANARO multipurpose-reactor project, and an associated R and D program. Recently, AECL began to develop the concept for a new Canadian Irradiation Research Facility (IRF) which will support the continued evolution of CANDU (CANadian Deuterium Uranium) technology and generate neutrons for basic and applied materials science. Additionally, AECL is currently developing a standardized MAPLE research-centre design with integrated neutron-application facilities; various reactor-core options have been optimized for different combinations of utilization: a 19-site core for neutron-beam applications and ancillary isotope production, a 31-site core for multipurpose materials testing and neutron-beam applications, and twin 18-site cores for high-flux neutron-beam applications. (author)

  17. Review of the use of Ceramium tenuicorne growth inhibition test for testing toxicity of substances, effluents, products sediment and soil

    Science.gov (United States)

    Eklund, Britta

    2017-08-01

    A growth inhibition test has been developed based on two clones of the red macroalga Ceramium tenuicorne, one originating from 7 PSU and the other from 20 PSU. The species can be adapted to different salinities and the test can be carried out between 4 and 32 PSU. This test became an ISO standard in 2010 (ISO 107 10) for testing of chemicals and water effluents. In this study new and published data has been compiled on toxicity of single substances, waste waters from pulp mills, leachates from antifouling paints, harbour sediments and soil used for maintenance of leisure boats. The results show that the alga is sensitive to both metals and organic compounds and to biocides used in antifouling paints. By testing leachates from antifouling paints these could be ranked according to their toxicity. Similarly, the toxicity of waste waters from pulp mills was determined and the efficiency of secondary treatment evaluated. Further, the test method proved useful to test the toxicity in sediment samples. Sediments from small town harbours and ship lanes were shown to be harmful and compounds originating from antifouling paints were responsible for a large part of the inhibiting effect. The alga proved to be sensitive to contaminants leaking from boat yard soil. The growth inhibition test is a robust test that has high repeatability and reproducibility and easily can be applied on water, soil and sediment samples without being too costly. The species is found worl-wide in temperate waters, which makes the results relevant for large areas. In the Baltic Sea C. tenuicorne is the most common red alga species and is thus particularly relevant for this area. The overall results show that contaminants from boat activities and the use of antifouling paints in particular pose a threat to the environment.

  18. Mechanical compression tests of beryllium pebbles after neutron irradiation up to 3000 appm helium production

    Energy Technology Data Exchange (ETDEWEB)

    Chakin, V., E-mail: vladimir.chakin@kit.edu [Karlsruhe Institute of Technology, Institite for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Rolli, R.; Moeslang, A. [Karlsruhe Institute of Technology, Institite for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Zmitko, M. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, no. 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain)

    2015-04-15

    Highlights: • Compression tests of highly neutron irradiated beryllium pebbles have been performed. • Irradiation hardening of beryllium pebbles decreases the steady-state strain-rates. • The steady-state strain-rates of irradiated beryllium pebbles exceed their swelling rates. - Abstract: Results: of mechanical compression tests of irradiated and non-irradiated beryllium pebbles with diameters of 1 and 2 mm are presented. The neutron irradiation was performed in the HFR in Petten, The Netherlands at 686–968 K up to 1890–2950 appm helium production. The irradiation at 686 and 753 K cause irradiation hardening due to the gas bubble formation in beryllium. The irradiation-induced hardening leads to decrease of steady-state strain-rates of irradiated beryllium pebbles compared to non-irradiated ones. In contrary, after irradiation at higher temperatures of 861 and 968 K, the steady-state strain-rates of the pebbles increase because annealing of irradiation defects and softening of the material take place. It was shown that the steady-state strain-rates of irradiated beryllium pebbles always exceed their swelling rates.

  19. Estimation of effective dose from the atmospheric nuclear tests due to the intake of marine products

    International Nuclear Information System (INIS)

    Nakano, Masanao

    2008-01-01

    The worldwide environmental protection is required by the public. A long-term environmental assessment from nuclear fuel cycle facilities to the aquatic environment also becomes more important to understand long-term risk of nuclear energy. Evaluation of long-term risk including not only in Japan but also in neighboring countries is considered to be necessary in order to develop sustainable nuclear power industry. The author successfully simulated the distribution of radionuclides in seawater and seabed sediment produced by atmospheric nuclear tests using LAMER (Long-term Assessment ModEl of Radionuclides in the oceans). A part of the LAMER calculated the advection-diffusion-scavenging processes for radionuclides in the oceans and the Japan Sea in cooperate with Oceanic General Circulation Model (OGCM) and was validated. The author is challenging to calculate probabilistic effective dose suggested by ICRP from intake of marine products due to atmospheric nuclear tests using the Monte Carlo method in the other part of LAMER. Depending on the deviation of each parameter, the 95th percentile of the probabilistic effective dose was from one third to two thirds of the 95th percentile of the deterministic effective dose in proforma calculation. It means that probabilistic assessment can contribute to the design and optimisation of a nuclear fuel cycle facility. (author)

  20. Genetic line comparisons and genetic parameters for endoparasite infections and test-day milk production traits.

    Science.gov (United States)

    May, Katharina; Brügemann, Kerstin; Yin, Tong; Scheper, Carsten; Strube, Christina; König, Sven

    2017-09-01

    Keeping dairy cows in grassland systems relies on detailed analyses of genetic resistance against endoparasite infections, including between- and within-breed genetic evaluations. The objectives of this study were (1) to compare different Black and White dairy cattle selection lines for endoparasite infections and (2) the estimation of genetic (co)variance components for endoparasite and test-day milk production traits within the Black and White cattle population. A total of 2,006 fecal samples were taken during 2 farm visits in summer and autumn 2015 from 1,166 cows kept in 17 small- and medium-scale organic and conventional German grassland farms. Fecal egg counts were determined for gastrointestinal nematodes (FEC-GIN) and flukes (FEC-FLU), and fecal larvae counts for the bovine lungworm Dictyocaulus viviparus (FLC-DV). The lowest values for gastrointestinal nematode infections were identified for genetic lines adopted to pasture-based production systems, especially selection lines from New Zealand. Heritabilities were low for FEC-GIN (0.05-0.06 ± 0.04) and FLC-DV (0.05 ± 0.04), but moderate for FEC-FLU (0.33 ± 0.06). Almost identical heritabilities were estimated for different endoparasite trait transformations (log-transformation, square root). The genetic correlation between FEC-GIN and FLC-DV was 1.00 ± 0.60, slightly negative between FEC-GIN and FEC-FLU (-0.10 ± 0.27), and close to zero between FLC-DV and FEC-FLU (0.03 ± 0.30). Random regression test-day models on a continuous time scale [days in milk (DIM)] were applied to estimate genetic relationships between endoparasite and longitudinal test-day production traits. Genetic correlations were negative between FEC-GIN and milk yield (MY) until DIM 85, and between FEC-FLU and MY until DIM 215. Genetic correlations between FLC-DV and MY were negative throughout lactation, indicating improved disease resistance for high-productivity cows. Genetic relationships between FEC-GIN and FEC-FLU with milk

  1. Production test engineering in FE-I4 system-on-chip to boost the reliability and high-quality demands in IBL applications

    International Nuclear Information System (INIS)

    Zivkovic, V A; Porret, D

    2013-01-01

    The article addresses production test development effort of the ATLAS FE-I4 integrated circuit. This particular production test targets manufacturing faults in the ICs and has been taken as a supplementary approach, besides standard functional test, to further decrease the risk of potential application failures. The Design-for-Test structures inside the digital part of the chip, together with the specially devised top-level simulations enabled straightforward test development and debug in the production test environment. The production test itself has been commissioned to the external test company, with the supervision of the FE-I4 team at the test floor.

  2. Value Added Productivity Indicators: A Statistical Comparison of the Pre-Test/Post-Test Model and Gain Model.

    Science.gov (United States)

    Weerasinghe, Dash; Orsak, Timothy; Mendro, Robert

    In an age of student accountability, public school systems must find procedures for identifying effective schools, classrooms, and teachers that help students continue to learn academically. As a result, researchers have been modeling schools and classrooms to calculate productivity indicators that will withstand not only statistical review but…

  3. A test of speech motor control on word level productions: The SPA Test (Dutch: Screening Pittige Articulatie)

    NARCIS (Netherlands)

    P. Dejonckere; F. Wijnen; Dr. Yvonne van Zaalen

    2009-01-01

    The primary objective of this article is to study whether an assessment instrument specifically designed to assess speech motor control on word level productions would be able to add differential diagnostic speech characteristics between people who clutter and people who stutter. It was hypothesized

  4. Development and Justification of a Risk Evaluation Matrix To Guide Chemical Testing Necessary To Select and Qualify Plastic Components Used in Production Systems for Pharmaceutical Products.

    Science.gov (United States)

    Jenke, Dennis

    2015-01-01

    An accelerating trend in the pharmaceutical industry is the use of plastic components in systems used to produce an active pharmaceutical ingredient or a finished drug product. If the active pharmaceutical ingredient, the finished drug product, or any solution used to generate them (for example, a process stream such as media, buffers, eluents, and the like) is contacted by a plastic component at any time during the production process, substances leached from the component may accumulate in the active pharmaceutical ingredient or finished drug product, affecting its safety and/or efficacy. In this article the author develops and justifies a semi-quantitative risk evaluation matrix that is used to determine the amount and rigor of component testing necessary and appropriate to establish that the component is chemically suitable for its intended use. By considering key properties of the component, the contact medium, the contact conditions, and the active pharmaceutical ingredient's or finished drug product's clinical conditions of use, use of the risk evaluation matrix produces a risk score whose magnitude reflects the accumulated risk that the component will interact with the contact solution to such an extent that component-related extractables will accumulate in the active pharmaceutical ingredient or finished drug product as leachables at levels sufficiently high to adversely affect user safety. The magnitude of the risk score establishes the amount and rigor of the testing that is required to select and qualify the component, and such testing is broadly grouped into three categories: baseline assessment, general testing, and full testing (extractables profiling). Production suites used to generate pharmaceuticals can include plastic components. It is possible that substances in the components could leach into manufacturing solutions and accumulate in the pharmaceutical product. In this article the author develops and justifies a semi-quantitative risk

  5. REIMEP-22 inter-laboratory comparison: "U Age Dating - Determination of the production date of a uranium certified test sample"

    OpenAIRE

    VENCHIARUTTI CELIA; VARGA ZSOLT; RICHTER Stephan; JAKOPIC Rozle; MAYER Klaus; AREGBE Yetunde

    2015-01-01

    The REIMEP-22 inter-laboratory comparison aimed at determining the production date of a uranium certified test sample (i.e. the last chemical separation date of the material). Participants in REIMEP-22 on "U Age Dating - Determination of the production date of a uranium certified test sample" received one low-enriched 20 mg uranium sample for mass spectrometry measurements and/or one 50 mg uranium sample for D-spectrometry measurements, with an undisclosed value for the production date. They ...

  6. Commissioning of indigenous microwave test facility for development and pilot production of 2 MW S-band magnetrons

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Wanmode, Y.D.; Hannurkar, P.R.; Prasad, Sharda

    2005-01-01

    To have self reliance in the field of microwave devices and to have consistent supply of pulsed magnetrons for the Indian accelerator programme. CAT initiated development of 2 MW S-Band pulsed magnetrons in collaboration with CEERI, Pilani. The design, development and testing of the microwave test facilities for ageing. conditioning and performance testing of Indian magnetrons, was successfully done by CAT indigenously. After the rigorous testing. the test facility was shifted, installed and commissioned at CEERI, Pilani by CAT. Over a period of 10 years, nine prototypes were aged and tested, two magnetrons were life tested and five magnetrons under production programme have been successfully conditioned and tested. Testing of more numbers is underway. The system details. commissioning aspects are discussed, results are shown. (author)

  7. 46 CFR 159.007-7 - Application for acceptance for production inspections and tests: Coast Guard action.

    Science.gov (United States)

    2010-10-01

    ... and tests: Coast Guard action. 159.007-7 Section 159.007-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL....007-7 Application for acceptance for production inspections and tests: Coast Guard action. (a) From...

  8. 77 FR 28281 - Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume...

    Science.gov (United States)

    2012-05-14

    ... Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume Chemical...]amino]- (CAS No. 1324-76-1), also known as C.I. Pigment Blue 61. EPA received an adverse comment regarding C.I. Pigment Blue 61. This document withdraws the revocation of testing requirements for C.I...

  9. Ensuring production-worthy OPC recipes using large test structure arrays

    Science.gov (United States)

    Cork, Christopher; Zimmermann, Rainer; Mei, Xin; Shahin, Alexander

    2007-03-01

    . An OPC correction recipe which gives acceptable verification results, based solely on one customer GDS is clearly not sufficient to guarantee that all future tape-outs from multiple customers will be similarly clean. Ad hoc changes made in reaction to problems seen at verification are risky, while they may solve one particular layout issue on one product there is no guarantee that the problem may simply shift to another configuration on a yet to be manufactured part. The need to re-qualify a recipe over multiple products at each recipe change can easily results in excessive computational requirements. A single layer at an advanced node typically needs overnight runs on a large processor farm. Much of this layout, however, is extremely repetitive, made from a few standard cells placed tens of thousands of times. An alternative and more efficient approach, suggested by this paper as a screening methodology, is to encapsulate the problematic structures into a programmable test structure array. The dimensions of these test structures are parameterized in software such that they can be generated with these dimensions varied over the space of the design rules and conceivable design styles. By verifying the new recipe over these test structures one could more quickly gain confidence that this recipe would be robust over multiple tape-outs. This paper gives some examples of the implementation of this methodology.

  10. Twisting Tongues to Test for Conflict-Monitoring in Speech Production

    Directory of Open Access Journals (Sweden)

    Daniel eAcheson

    2014-04-01

    Full Text Available A number of recent studies have hypothesized that monitoring in speech production may occur via domain-general mechanisms responsible for the detection of response conflict. Outside of language, two ERP components have consistently been elicited in conflict-inducing tasks (e.g., the flanker task: The stimulus-locked N2 on correct trials, and the response-locked error-related negativity (ERN. The present investigation used these electrophysiological markers to test whether a common response conflict monitor is responsible for monitoring in speech and non-speech tasks.EEG was recorded while participants performed a tongue twister (TT task and a manual version of the flanker task. In the TT task, people rapidly read sequences of four nonwords arranged in TT and non-TT patterns three times. In the flanker task, people responded with a left/right button press to a center-facing arrow, and conflict was manipulated by the congruency of the flanking arrows.Behavioral results showed typical effects of both tasks, with increased error rates and slower speech onset times for TT relative to non-TT trials and for incongruent relative to congruent flanker trials. In the flanker task, stimulus-locked EEG analyses replicated previous results, with a larger N2 for incongruent relative to congruent trials, and a response-locked ERN. In the TT task, stimulus-locked analyses revealed broad, frontally-distributed differences beginning around 50 ms and lasting until just before speech initiation, with TT trials more negative than non-TT trials; response-locked analyses revealed an ERN. Correlation across these measures showed some correlations within a task, but little evidence of systematic cross-task correlation. Although the present results do not speak against conflict signals from the production system serving as cues to self-monitoring, they are not consistent with signatures of response conflict being mediated by a single, domain-general conflict monitor.

  11. Product analysis and initial reliability testing of the total mesorectal excision-quality assessment instrument.

    Science.gov (United States)

    Simunovic, Marko R; DeNardi, Franco G; Coates, Angela J; Szalay, David A; Eva, Kevin W

    2014-07-01

    Product analysis of rectal cancer resection specimens before specimen fixation may provide an immediate and relevant evaluation of surgical performance. We tested the interrater reliability (IRR) of a product analysis tool called the Total Mesorectal Excision-Quality Assessment Instrument (TME-QA). Participants included two gold standard raters, five pathology assistants, and eight pathologists. Domains of the TME-QA reflect total mesorectal excision principles including: (1) completeness of mesorectal margin; (2) completeness of mesorectum; (3) coning of distal mesorectum; (4) physical defects; and (5) overall specimen quality. Specimens were scored independently. We used the generalizability theory to assess the tool's internal consistency and IRR. There were 39 specimens and 120 ratings. Mean overall specimen quality scores for the gold standard raters, pathologists, and assistants were 4.43, 4.43, and 4.50, respectively (p > 0.85). IRR for the first nine items was 0.68 for the full sample, 0.62 for assistants alone, 0.63 for pathologists alone, and 0.74 for gold standard raters alone. IRR for the item overall specimen quality was 0.67 for the full sample, 0.45 for assistants, 0.80 for pathologists, and 0.86 for gold standard raters. IRR increased for all groups when scores were averaged across two raters. Assessment of surgical specimens using the TME-QA may provide rapid and relevant feedback to surgeons about their technical performance. Our results show good internal consistency and IRR when the TME-QA is used by pathologists. However, for pathology assistants, multiple ratings with the averaging of scores may be needed.

  12. Development of a calibration methodology and tests of kerma area product meters

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida

    2013-01-01

    The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient's skin doesn't exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter. (author)

  13. Respiratory symptoms and pulmonary function tests in security and safety products plant workers.

    Science.gov (United States)

    Balbay, Ege Gulec; Toru, Umran; Arbak, Peri; Balbay, Oner; Suner, Kezban Ozmen; Annakkaya, Ali Nihat

    2014-01-01

    Lock and key factory workers are under the risk of metal pneumoconiosis and occupational asthma. In this cross-sectional study, it's aimed to evaluate the relationship between metal dust exposure and respiratory symptoms, pulmonary function tests of workers in different section of lock and key factory. 54 male workers (mean age, 32.8 ± 5.4) in a security and safety products plant were evaluated for respiratory symptoms, pulmonary function tests and smoking habits. Results have been interpreted by comparison of the painting (28/54) and grinding group workers (26/54). There was no significant difference between painting (32.1 ± 4.8) and grinding (33.6 ± 6.1) groups regarding mean age (P > 0.05). Smokers were in significantly higher in grinding group (18/26). Cough and sputum were reported 14.3% (4/28) in painting and 3.8% (1/26) in grinding workers (P > 0.05). Chest tightness was seen in 7.1% and 7.7% of painting and grinding workers, respectively (P > 0.05). But no chest tightness was reported in both groups when they were away work. Breathlessness was seen in 10.7% and 7.7% of painting and grinding workers, respectively (P > 0.05). Breathlessness was similar in both groups (7.1% vs. 3.8%) when they were away work. When comparing painting and grinding workers respiratory functions no significant difference observed. Chest radiography in painting and grinding workers showed hyperlucency (3.6% vs.11.4%), respectively. Painting groups in lock and key factory workers had more but statistically insignificantrespiratory complaints. Interestingly, chest tightness was only observed when both groups were at work. It was thought that ventilation and using personal protective equipment in factory could provide significant benefits.

  14. Test of the linear-no threshold theory of radiation carcinogenesis for inhaled radon decay products

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1995-01-01

    Data on lung cancer mortality rates vs. average radon concentration in homes for 1,601 U.S. counties are used to test the linear-no threshold theory. The widely recognized problems with ecological studies, as applied to this work, are addressed extensively. With or without corrections for variations in smoking prevalence, there is a strong tendency for lung cancer rates to decrease with increasing radon exposure, in sharp contrast to the increase expected from the theory. The discrepancy in slope is about 20 standard deviations. It is shown that uncertainties in lung cancer rates, radon exposures, and smoking prevalence are not important and that confounding by 54 socioeconomic factors, by geography, and by altitude and climate can explain only a small fraction of the discrepancy. Effects of known radon-smoking prevalence correlations - rural people have higher radon levels and smoke less than urban people, and smokers are exposed to less radon than non-smokers - are calculated and found to be trivial. In spite of extensive efforts, no potential explanation for the discrepancy other than failure of the linear-no threshold theory for carcinogenesis from inhaled radon decay products could be found. (author)

  15. A study of production of radioactive environmental reference materials used for proficiency testing program in Taiwan

    International Nuclear Information System (INIS)

    Peng, En-Chi; Wang, Jeng-Jong

    2013-01-01

    To realise radioactive environmental reference materials in Taiwan, seven environmental materials of soil, water, vegetation, meat, airborne particles (filter paper), milk and mushroom samples that are frequently encountered were used to establish the preparation of the reference materials. These seven environmental materials were collected, checked for freedom from radioactivity and prepared according to their properties. The preparation was carried out by using activity about 10–100 times that of the minimum detectable activity (MDA) in routine measurements in the radioactive standard used to spike the inactive material and this standard is traceable to national ionising radioactivity standards (TAF, 2004). To demonstrate sample traceability to the added standard, each sample was carefully measured and its uncertainty evaluated. Based on the recommendations of ISO Guide 35 for evaluation of reference materials and with the above assessment and verification procedures, the uncertainties (k=1) of the spike activity used in making reference materials were: 60 Co≤4.6%, 134 Cs≤4.7%, 137 Cs≤5.0%, total β≤0.6% and 3 H≤1.3%. - Highlights: • Seven kinds environmental materials were used to establish the production of the RMs. • Spiking the traceable standard radioactive source to the blank substance. • Each sample was carefully evaluated for its uncertainty. • The performance of the RMs was estimated with the Proficiency Testing program report. • The ability of the environment RMs in the configuration is quite good

  16. Monitoring production using surface deformation: the Hijiori test site and the Okuaizu geothermal field

    International Nuclear Information System (INIS)

    Vasco, D.W.; Karasaki, Kenzi

    2002-01-01

    Production in geothermal reservoirs often leads to observable surface displacement. As shown in this paper, there is a direct relationship between such displacement and reservoir dynamics. This relationship is exploited in order to image fluid flow at two geothermal field sites. At the first locality, the Hijiori Hot Dry Rock (HDR) test site, 17 tilt meters record deformation associated with a 2.2 km deep injection experiment. Images of fluid migration along a ring fracture system of the collapsed Hijiori caldera are obtained. At the Okuaizu geothermal field, leveling and tilt meter data provide constraints on long- and short-term fluid movement within the reservoir. A set of 119 leveling data suggest that the north-to-northeast trending Takiyagawa fault acts as a barrier to flow. The northwesterly oriented Chinoikezawa and Sarukurazawa faults appear to channel fluid from the southeast. The tilt data from Okuaizu indicate that a fault paralleling the Takiyagawa fault zone acts as a conduit to transient flow, on a time scale of several weeks. The volume strain in a region adjacent to the injection wells reaches a maximum and then decreases with time. The transient propagation of fluid along the fault may be due to pressure build-up, resulting from the re-initiation of injection. (author)

  17. Quantification of Plasmodiophora brassicae Using a DNA-Based Soil Test Facilitates Sustainable Oilseed Rape Production.

    Science.gov (United States)

    Wallenhammar, Ann-Charlotte; Gunnarson, Albin; Hansson, Fredrik; Jonsson, Anders

    2016-04-22

    Outbreaks of clubroot disease caused by the soil-borne obligate parasite Plasmodiophora brassicae are common in oilseed rape (OSR) in Sweden. A DNA-based soil testing service that identifies fields where P. brassicae poses a significant risk of clubroot infection is now commercially available. It was applied here in field surveys to monitor the prevalence of P. brassicae DNA in field soils intended for winter OSR production and winter OSR field experiments. In 2013 in Scania, prior to planting, P. brassicae DNA was detected in 60% of 45 fields on 10 of 18 farms. In 2014, P. brassicae DNA was detected in 44% of 59 fields in 14 of 36 farms, in the main winter OSR producing region in southern Sweden. P. brassicae was present indicative of a risk for >10% yield loss with susceptible cultivars (>1300 DNA copies g soil(-1)) in 47% and 44% of fields in 2013 and 2014 respectively. Furthermore, P. brassicae DNA was indicative of sites at risk of complete crop failure if susceptible cultivars were grown (>50 000 copies g(-1) soil) in 14% and 8% of fields in 2013 and 2014, respectively. A survey of all fields at Lanna research station in western Sweden showed that P. brassicae was spread throughout the farm, as only three of the fields (20%) showed infection levels below the detection limit for P.brassicae DNA, while the level was >50,000 DNA copies g(-1) soil in 20% of the fields. Soil-borne spread is of critical importance and soil scraped off footwear showed levels of up to 682 million spores g(-1) soil. Soil testing is an important tool for determining the presence of P. brassicae and providing an indication of potential yield loss, e.g., in advisory work on planning for a sustainable OSR crop rotation. This soil test is gaining acceptance as a tool that increases the likelihood of success in precision agriculture and in applied research conducted in commercial oilseed fields and at research stations. The present application highlights the importance of prevention of

  18. Quantification of Plasmodiophora brassicae Using a DNA-Based Soil Test Facilitates Sustainable Oilseed Rape Production

    Directory of Open Access Journals (Sweden)

    Ann-Charlotte Wallenhammar

    2016-04-01

    Full Text Available Outbreaks of clubroot disease caused by the soil-borne obligate parasite Plasmodiophora brassicae are common in oilseed rape (OSR in Sweden. A DNA-based soil testing service that identifies fields where P. brassicae poses a significant risk of clubroot infection is now commercially available. It was applied here in field surveys to monitor the prevalence of P. brassicae DNA in field soils intended for winter OSR production and winter OSR field experiments. In 2013 in Scania, prior to planting, P. brassicae DNA was detected in 60% of 45 fields on 10 of 18 farms. In 2014, P. brassicae DNA was detected in 44% of 59 fields in 14 of 36 farms, in the main winter OSR producing region in southern Sweden. P. brassicae was present indicative of a risk for >10% yield loss with susceptible cultivars (>1300 DNA copies g soil−1 in 47% and 44% of fields in 2013 and 2014 respectively. Furthermore, P. brassicae DNA was indicative of sites at risk of complete crop failure if susceptible cultivars were grown (>50 000 copies g−1 soil in 14% and 8% of fields in 2013 and 2014, respectively. A survey of all fields at Lanna research station in western Sweden showed that P. brassicae was spread throughout the farm, as only three of the fields (20% showed infection levels below the detection limit for P.brassicae DNA, while the level was >50,000 DNA copies g−1 soil in 20% of the fields. Soil-borne spread is of critical importance and soil scraped off footwear showed levels of up to 682 million spores g−1 soil. Soil testing is an important tool for determining the presence of P. brassicae and providing an indication of potential yield loss, e.g., in advisory work on planning for a sustainable OSR crop rotation. This soil test is gaining acceptance as a tool that increases the likelihood of success in precision agriculture and in applied research conducted in commercial oilseed fields and at research stations. The present application highlights the importance of

  19. Semipalatinsk test site: Parameters of radionuclide transfer to livestock and poultry products under actual radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Baigazinov, Z.; Lukashenko, S. [Institute of Radiation Safety and Ecology (Kazakhstan)

    2014-07-01

    The IAEA document 'Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Terrestrial and Freshwater Environments' published in 2010 is one of the major sources of knowledge about the migration parameters of radionuclides in the agro-ecosystems that is necessary to assess the dose loads to the population. It is known from there that Sr and Cs transfer has been studied thoroughly, however the factors vary over a wide range. Few studies were conducted for Pu and Am transfer. It should be noted that the studies carried out in real conditions of radioactive contamination, i.e. under natural conditions is also very few. In this regard, since 2007 the territory of the former Semipalatinsk Test Site has been used for comprehensive radioecological studies, where the major radionuclides to be investigated are {sup 90}Sr, {sup 137}Cs, {sup 239+240}Pu, {sup 241}Am. The objects for these studies are birds and animals typical for the region, as well as products obtained from them (lamb, beef, horse meat, chicken, pork, cow's milk, mare's milk, eggs, chicken, chicken feathers, wool, leather). It should be noted that these products are the main agricultural goods that are available in these areas. The studies have been conducted with grazing animals in the most contaminated areas of the test site. Some groups of animals and birds were fed to contaminated feed, soil, contaminated water. Radionuclide intake by animal body with air were studied. Husbandry periods for animals and birds ranged from 1 to 150 days. The transfer parameters to cow and mare's milk have been investigated at single and prolonged intake of radionuclides, also their excretion dynamics has been studied. The studies revealed features of the radionuclide transfer into organs and tissues of animals and birds intaken with hay, water and soil. The results showed that the transfer factors vary up to one order. A relationship has been identified between distribution of

  20. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  1. Evaluation of preservative efficacy in pharmaceutical products: the use of psychrotolerant, low-nutrient preferring microbes in challenge tests.

    Science.gov (United States)

    Charnock, C; Otterholt, E

    2012-10-01

    Preservative efficacy in medicines is typically investigated using challenge tests. In such tests, the product is artificially contaminated with a high concentration of standard bacterial and fungal test strains such as Pseudomonas aeruginosa and Candida albicans. The rate and extent of reductions in inoculum viability over a specified period forms the basis for acceptance/rejection of preservative efficacy. None of the strains named for inclusion in the challenge test outlined in the European Pharmacopoeia are associated with the contamination of high-quality water used in pharmaceutical production. Alpha- and Betaproteobacteria are easily the most common microbes in waters intended for pharmaceutical production. In addition, none of the standard test strain panel prefer low-nutrient, dilute conditions or grow at or around refrigeration temperatures. This is important because the water activity and nutrient content of medicines can vary greatly and medicines are often stored cold. We investigate the relevance of these factors when testing preservative efficacy by including other strains in challenge tests. Psychrotolerant, low-nutrient preferring strains (Beta- and Alphaproteobacteria and a yeast) were isolated from pristine waters. These were compared in challenge tests with C. albicans and P. aeruginosa using different storage temperatures. Pharmaceutical products differing widely in water-content, pH and preservative systems were included in the study. Regardless of the type of medicine tested C. albicans always showed superior survival characteristics to the yeast isolate (Cryptococcus terricola). One of the three screened bacterial strains (a Sphingomonas sp.) survived significantly better than P. aeruginosa in all but one product tested. However, the results for all products taken together cannot easily be explained by reference to this strain's psychrotolerancy or its preference for dilute, low-nutrient environments. This study supports previous work

  2. Long-term product consistency test of simulated 90-19/Nd HLW glass

    International Nuclear Information System (INIS)

    Gan, X.Y.; Zhang, Z.T.; Yuan, W.Y.; Wang, L.; Bai, Y.; Ma, H.

    2011-01-01

    Chemical durability of 90-19/Nd glass, a simulated high-level waste (HLW) glass in contact with the groundwater was investigated with a long-term product consistency test (PCT). Generally, it is difficult to observe the long term property of HLW glass due to the slow corrosion rate in a mild condition. In order to overcome this problem, increased contacting surface (S/V = 6000 m -1 ) and elevated temperature (150 o C) were employed to accelerate the glass corrosion evolution. The micro-morphological characteristics of the glass surface and the secondary minerals formed after the glass alteration were analyzed by SEM-EDS and XRD, and concentrations of elements in the leaching solution were determined by ICP-AES. In our experiments, two types of minerals, which have great impact on glass dissolution, were found to form on 90-19/Nd HLW glass surface when it was subjected to a long-term leaching in the groundwater. One is Mg-Fe-rich phyllosilicates with honeycomb structure; the other is aluminosilicates (zeolites). Mg and Fe in the leaching solution participated in the formation of phyllosilicates. The main components of phyllosilicates in alteration products of 90-19/Nd HLW glass are nontronite (Na 0.3 Fe 2 Si 4 O 10 (OH) 2 .4H 2 O) and montmorillonite (Ca 0.2 (Al,Mg) 2 Si 4 O 10 (OH) 2 .4H 2 O), and those of aluminosilicates are mordenite ((Na 2 ,K 2 ,Ca)Al 2 Si 10 O 24 .7H 2 O)) and clinoptilolite ((Na,K,Ca) 5 Al 6 Si 30 O 72 .18H 2 O). Minerals like Ca(Mg)SO 4 and CaCO 3 with low solubility limits are prone to form precipitant on the glass surface. Appearance of the phyllosilicates and aluminosilicates result in the dissolution rate of 90-19/Nd HLW glass resumed, which is increased by several times over the stable rate. As further dissolution of the glass, both B and Na in the glass were found to leach out in borax form.

  3. Ethnic hair care products may increase false positives in hair drug testing.

    Science.gov (United States)

    Kidwell, David A; Smith, Frederick P; Shepherd, Arica R

    2015-12-01

    The question of why different races appear more susceptible to hair contamination by external drugs remains controversial. This research studied susceptibility of head hair to external cocaine and methamphetamine when hair products have been applied. Three different chemical classes of ethnic hair products were applied to Caucasian, Asian, and African hair. Some products increased the methamphetamine and cocaine concentrations in all hair types. A unique finding of this research is that certain ethnic hair products can replace moisture as a diffusion medium, thereby increasing the susceptibility to contamination over 100-fold compared to petroleum-based products. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Safety considerations for continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour

    International Nuclear Information System (INIS)

    Onuki, Kaoru; Akino, Norio; Shimizu, Saburo; Nakajima, Hayato; Higashi, Shunichi; Kubo, Shinji

    2001-03-01

    Since the thermochemical hydrogen production Iodine-Sulfur process decomposes water into hydrogen and oxygen using toxic chemicals such as sulfuric acid, iodine and hydriodic acid, safety considerations are very important in its research and development. Therefore, before construction of continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour, comprehensive safety considerations were carried out to examine the design and construction works of the test apparatus, and the experimental plans using the apparatus. Emphasis was given on the safety considerations on prevention of breakage of glasswares and presumable abnormalities, accidents and their countermeasures. This report summarizes the results of the considerations. (author)

  5. An Overview of Trials´Accreditation and Recognition of Brazilian Tests Used for the Safety Evaluation of Cosmetic Products

    Directory of Open Access Journals (Sweden)

    Luciana dos Santos Almeida

    2016-06-01

    Full Text Available For some time, Brazil has been appointed as one of the greatest consumers of cosmetic products in the world. Although cosmetics may seem harmless, destined exclusively to enhance personal appearance or to clean and protect the skin, hair and nails, new studies and events are highlighting the need to evaluate the safety of such products. The present work interrelated the lifecycle of a cosmetic product with the safety trials and tests applicable to some cycle phases. From this information, a survey was made of accredited Conformity Assessment Bodies (CAB and test facilities recognized by the General Coordination for Accreditation (CGCRE which are competent respectively to carry out safety trials and tests of cosmetics. Twenty five competent laboratories were identified to carry out chemical and/or biological trials of cosmetics, according to the legislation ABNT ISO IEC 17025:2005, and 10 test facilities recognized by the Compliance Monitoring Program that can carry out tests of the development of a product for register purposes, aiming at human health and safety. It is interesting to notice that Brazil has accredited laboratories to carry out trials that are critical for the health of the population, such as the levels of heavy metals and the presence of pathogens. On the other hand, CGCRE does not have a program to recognize safety clinical trials. The importance of this kind of study is understood, considering the world history of adverse reactions and the great consumption of cosmetics in the country.

  6. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421

  7. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation.

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session.

  8. Production and detection of cold anti-hydrogen atoms A first step towards high precision CPT test

    CERN Document Server

    Variola, A; Bonomi, G; Boutcha, A; Bowe, P; Carraro, C; Cesar, C L; Charlton, M; Doser, Michael; Filippini, V; Fontana, A; Fujiwara, M C; Funakoshi, R; Genova, P; Hangst, J S; Hayano, R S; Jørgensen, L V; Lagomarsino, V; Landua, Rolf; Lindelöf, D; Lodi-Rizzini, E; Macri, M; Madsen, N; Manuzio, G; Montagna, P; Pruys, H S; Regenfus, C; Rotondi, A; Riedler, P; Testera, G; Van der Werf, D P

    2003-01-01

    Observations of anti-hydrogen in small quantities have been reported at CERN and at FermiLab, but these experiments were not suited to spectroscopy experiments. In 2002 the ATHENA collaboration reported the production and detection of very low energy anti-hydrogen atoms produced in cryogenic environment. This is the first major step in the study of antiatom's internal structure and it can lead to a high precision test of the CPT fundamental symmetry. The method of production and detection of cold anti-hydrogen will be introduced. The absolute rate of anti-hydrogen production and the signal to background ratio in the ATHENA experiment will be discussed. (7 refs) .

  9. Production controls (PC) and technical verification testing (TVT). A methodology for the control and tracking of LILW waste package conditioning

    International Nuclear Information System (INIS)

    Leon, A.M.; Nieto, J.L.L.; Garrido, J.G.

    2003-01-01

    As part of its low and intermediate level radioactive waste (LILW) characterisation and acceptance activities, ENRESA has set up a quality control programme that covers the different phases of radioactive waste package production and implies different levels of tracking in generation, assessment of activity and control of the documentation associated therewith. Furthermore, ENRESA has made available the mechanisms required for verification, depending on the results of periodic sampling, of the quality of the end product delivered by the waste producers. Both processes are included within the framework of two programmes of complementary activities: production controls (PC) and technical verification testing (TVT). (orig.)

  10. Fission products and nuclear fuel behaviour under severe accident conditions part 1: Main lessons learnt from the first VERDON test

    Science.gov (United States)

    Pontillon, Y.; Geiger, E.; Le Gall, C.; Bernard, S.; Gallais-During, A.; Malgouyres, P. P.; Hanus, E.; Ducros, G.

    2017-11-01

    This paper describes the first VERDON test performed at the end of September 2011 with special emphasis on the behaviour of fission products (FP) and actinides during the accidental sequence itself. Two other papers discuss in detail the post-test examination results (SEM, EPMA and SIMS) of the VERDON-1 sample. The first VERDON test was devoted to studying UO2 fuel behaviour and fission product releases under reducing conditions at very high temperature (∼2883 K), which was able to confirm the very good performance of the VERDON loop. The fuel sample did not lose its integrity during this test. According to the FP behaviour measured by the online gamma station (fuel sight), the general classification of the FP in relation to their released fraction is very accurate, and the burn-up effect on the release rate is clearly highlighted.

  11. Cryogenic system for production testing and measurement of Fermilab energy saver superconducting magnets

    International Nuclear Information System (INIS)

    Cooper, W.E.; Bianchi, A.J.; Barger, R.K.; Johnson, F.B.; McGuire, K.J.; Pinyan, K.D.; Wilson, F.R.

    1983-03-01

    The cryogenic system of the Fermilab Magnet Test Facility has been used to provide cooling for the testing of approximately 1200 Energy Saver superconducting magnets. The system provides liquid helium, liquid nitrogen, gas purification, and vacuum support for six magnet test stands. It provides for simultaneous high current testing of two superconducting magnets and non-high current cold testing of two additional magnets. The cryogenic system has been in operation for about 32000 hours. The 1200 magnets have taken slightly more than three years to test

  12. Possible checking of technical parameters in nondestructive materials and products testing

    International Nuclear Information System (INIS)

    Kesl, J.

    1987-01-01

    The requirements are summed up for partial technical parameters of instruments and facilities for nondestructive testing by ultrasound, radiography, by magnetic, capillary and electric induction methods. The requirements and procedures for testing instrument performance are presented for the individual methods as listed in domestic and foreign standards, specifications and promotional literature. The parameters to be tested and the methods of testing, including the testing and calibration instruments are shown in tables. The Czechoslovak standards are listed currently valid for nondestructive materials testing. (M.D.)

  13. Cryogenic system for production testing and measurement of Fermilab energy saver superconducting magnets

    International Nuclear Information System (INIS)

    Cooper, W.E.; Barger, R.K.; Bianchi, A.J.; Cooper, W.E.; Johnson, F.B.; McGuire, K.J.; Pinyan, K.D.; Wilson, F.R.

    1983-01-01

    The cryogenic system of the Fermilab Magnet Test Facility has been used to provide cooling for the testing of approximately 1200 Energy Saver superconducting magnets. The system provides liquid helium, liquid nitrogen, gas purification, and vacuum support for six magnet test stands. It provides for simultaneous high current testing of two superconducting magnets and nonhigh current cold testing of two additional magnets. The cryogenic system has been in operation for about 32000 hours. The 1200 magnets have taken slightly more than three years to test

  14. The Determinants of Productivity in Medical Testing: Intensity and Allocation of Care*

    Science.gov (United States)

    Abaluck, Jason; Agha, Leila; Kabrhel, Chris; Raja, Ali; Venkatesh, Arjun

    2017-01-01

    A large body of research has investigated whether physicians overuse care. There is less evidence on whether, for a fixed level of spending, doctors allocate resources to patients with the highest expected returns. We assess both sources of inefficiency exploiting variation in rates of negative imaging tests for pulmonary embolism. We document enormous across-doctor heterogeneity in testing conditional on patient population, which explains the negative relationship between physicians’ testing rates and test yields. Furthermore, doctors do not target testing to the highest risk patients, reducing test yields by one third. Our calibration suggests misallocation is more costly than overuse. PMID:29104293

  15. The bases for optimisation of scheduled repairs and tests of safety systems to improve the NPP productive efficiency

    International Nuclear Information System (INIS)

    Bilej, D.V.; Vasil'chenko, S.V.; Vlasenko, N.I.; Vasil'chenko, V.N.; Skalozubov, V.I.

    2004-01-01

    In the frames of risk-informed approaches the paper proposed the theoretical bases for methods of optimisation of scheduled repairs and tests of safety systems at nuclear power plants. The optimisation criterion is the objective risk function minimising. This function depends on the scheduled repairs/tests periodicity and the allowed time to bring the system channel to a state of non-operability. The main optimisation direct is to reduce the repair time with the purpose of enhancement of productive efficiency

  16. Performance test results of helium gas circulator of mock-up test facility with full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akira; Kato, Michio; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Hydrogen production system by steam reforming of methane will be connected to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) against development of nuclear heat utilization system. To obtain design and safety database of the HTTR hydrogen production system, mock-up test facility with full-scale reaction was constructed in FY 2001 and hydrogen of 120m{sup 3}N{sub /}h was successfully produced in overall performance test. This report describes performance test results of a helium gas circulator in this facility. The circulator performance curves regarding to pressure-rise, input power and adiabatic thermal efficiency at standard revolution number were made based on the measured flow-rate, temperature and pressure data in overall performance test. The circulator performance prediction code was made based on these performance curves. The code can calculate revolution number, electric power and temperature-rise of the circulator using flow-rate, inlet temperature, inlet pressure and pressure-rise data. The verification of the code was carried out with the test data in FY 2002. Total pressure loss of the helium gas circulation loop was also evaluated. The circulator should be operated in conditions such as pressure from 2.7MPa to 4.0MPa and flow-rate from 250g/s to 400g/s and at maximum pressure-rise of 250 kPa in test operation. It was confirmed in above verification and evaluations that the circulator had performance to satisfy above conditions within operation limitation of the circulator such as maximum input-power of 150 kW and maximum revolution number of 12,000 rpm. (author)

  17. PID Testing Method Suitable for Process Control of Solar Cells Mass Production

    Directory of Open Access Journals (Sweden)

    Xianfang Gou

    2015-01-01

    Full Text Available Voltage bias of several hundred volts which are applied between solar cells and module frames may lead to significant power losses, so-called potential-induced degradation (PID, in normal photovoltaic (PV installations system. Modules and minimodules are used to conduct PID test of solar cells. The test procedure is time consuming and of high cost, which cannot be used as process monitoring method during solar cells fabrication. In this paper, three kinds of test including minimodule, Rsh, and V-Q test are conducted on solar cells or wafers with SiNx of different refractive index. All comparisons between test results of Rsh, V-Q, and minimodule tests have shown equal results. It is shown that Rsh test can be used as quality inspection of solar cells and V-Q test of coated wafer can be used as process control of solar cells.

  18. 40 CFR 1048.310 - How must I select engines for production-line testing?

    Science.gov (United States)

    2010-07-01

    ... intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission standard. (1) Determine the 95...)). (e) After each new test, recalculate the required sample size using the updated mean values, standard...

  19. 40 CFR 1054.310 - How must I select engines for production-line testing?

    Science.gov (United States)

    2010-07-01

    ...% confidence intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission standard (or family...)). (e) After each new test, recalculate the required sample size using the updated mean values, standard...

  20. 40 CFR 1045.310 - How must I select engines for production-line testing?

    Science.gov (United States)

    2010-07-01

    ... select and test one more engine. Then, calculate the required sample size for the model year as described.... It defines 95% confidence intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission...

  1. 76 FR 65385 - Testing of Certain High Production Volume Chemicals; Third Group of Chemicals

    Science.gov (United States)

    2011-10-21

    ... Mutations: Bacterial Reverse Mutation Test (in vitro): 40 CFR 799.9510. b. Chromosomal Damage: In Vitro... alternate test. 6. Mammalian Toxicity--Repeated Dose/Reproduction/Developmental--a. Combined Repeated Dose Toxicity Study with the Reproduction/ Developmental Toxicity Screening Test: 40 CFR 799.9365. b...

  2. Personality Testing and Workplace Training: Exploring Stakeholders, Products and Purpose in Western Europe

    Science.gov (United States)

    Lundgren, Henriette; Kroon, Brigitte; Poell, Rob F.

    2017-01-01

    Purpose: The purpose of this paper is to explore how and why personality tests are used in workplace training. This research paper is guided by three research questions that inquire about the role of external and internal stakeholders, the value of psychometric and practical considerations in test selection, and the purpose of personality test use…

  3. 76 FR 971 - Energy Conservation Program for Consumer Products: Test Procedures for Clothes Dryers and Room...

    Science.gov (United States)

    2011-01-06

    .... Detergent Specifications for Clothes Dryer Test Cloth Preconditioning 5. Changes To Reflect Current Usage... conservation standard; (3) updated detergent specifications for clothes dryer test cloth preconditioning; (4... detergent specifications for clothes dryer test cloth preconditioning; (7) update the references to external...

  4. THE INFLUENCE OF A MATHEMATICAL MODEL IN PRODUCTION STRATEGY: CONCEPTUAL DEVELOPMENT AND EMPIRICAL TEST

    Directory of Open Access Journals (Sweden)

    Paulo Cesar Chagas Rodrigues

    2012-07-01

    Full Text Available Acquire and produce what is strictly necessary are the goals of the organizations, since they aim companies more competitive and thereby reducing production costs. The research method is applied in nature, with a qualitative and quantitative approach, in which the objective of the research will be: exploratory and descriptive, with technical procedures, divided into: bibliographic, documentary, survey and concluding with a case study. On this assumption the main objective of this research is to develop and analyze a mathematical model that minimizes costs and maximizes the postponement of stocks in a company in the pulp, paper and paper products. Having been found only four papers, two articles and two theses that deal with the issue of demand management, supply chain and inventory postponement. These studies address the issue by modeling the productive time of the supply chain. For production segments this research may enable development of management practices demand and production strategy, allowing cost reductions and productivity gains possible. With the development of the mathematical model could ever analyze the behavior of demand and its influence on the productive strategy, strategy formulation regarding the purchase of raw materials and finished product storage in the last four years the company's results for the proposed model.

  5. Accelerated stress testing in a time-driven product development process

    NARCIS (Netherlands)

    Lu, Y.; Loh, H.T.; Brombacher, A.C.; Ouden, den P.H.

    2000-01-01

    In order to compete in the market, companies have to produce the right products with a shorter time to market and at lower costs than before. Shorter time to market requires the product development process (PDP) to change the way of working from the classical ‘wait and react’ to anticipating and

  6. For a Psycholinguistic Model of Handwriting Production: Testing the Syllable-Bigram Controversy

    Science.gov (United States)

    Kandel, Sonia; Peereman, Ronald; Grosjacques, Geraldine; Fayol, Michel

    2011-01-01

    This study examined the theoretical controversy on the impact of syllables and bigrams in handwriting production. French children and adults wrote words on a digitizer so that we could collect data on the local, online processing of handwriting production. The words differed in the position of the lowest frequency bigram. In one condition, it…

  7. 75 FR 82074 - Fee Adjustment for Testing, Evaluation, and Approval of Mining Products

    Science.gov (United States)

    2010-12-29

    ..., and Approval of Mining Products AGENCY: Mine Safety and Health Administration (MSHA), Labor. ACTION..., evaluating, and approving mining products as provided by 30 CFR part 5. MSHA charges applicants a fee to... materials manufactured for use in the mining industry. The new fee schedule, effective January 1, 2011, is...

  8. Anomalous Thrust Production from an RF Test Device Measured on a Low-Thrust Torsion Pendulum

    Science.gov (United States)

    Brady, David; White, Harold G.; March, Paul; Lawrence, James T.; Davies, Frank J.

    2014-01-01

    This paper describes the eight-day August 2013 test campaign designed to investigate and demonstrate viability of using classical magnetoplasmadynamics to obtain a propulsive momentum transfer via the quantum vacuum virtual plasma. This paper will not address the physics of the quantum vacuum plasma thruster, but instead will describe the test integration, test operations, and the results obtained from the test campaign. Approximately 30-50 micro-Newtons of thrust were recorded from an electric propulsion test article consisting primarily of a radio frequency (RF) resonant cavity excited at approximately 935 megahertz. Testing was performed on a low-thrust torsion pendulum that is capable of detecting force at a single-digit micronewton level, within a stainless steel vacuum chamber with the door closed but at ambient atmospheric pressure. Several different test configurations were used, including two different test articles as well as a reversal of the test article orientation. In addition, the test article was replaced by an RF load to verify that the force was not being generated by effects not associated with the test article. The two test articles were designed by Cannae LLC of Doylestown, Pennsylvania. The torsion pendulum was designed, built, and operated by Eagleworks Laboratories at the NASA Johnson Space Center of Houston, Texas. Approximately six days of test integration were required, followed by two days of test operations, during which, technical issues were discovered and resolved. Integration of the two test articles and their supporting equipment was performed in an iterative fashion between the test bench and the vacuum chamber. In other words, the test article was tested on the bench, then moved to the chamber, then moved back as needed to resolve issues. Manual frequency control was required throughout the test. Thrust was observed on both test articles, even though one of the test articles was designed with the expectation that it would not

  9. Investigation of Psychometric Properties of the Test for Creative Thinking-Drawing Production: Evidence from Study in Latvia

    Science.gov (United States)

    Kalis, Emils; Roke, Liga; Krumina, Indra

    2016-01-01

    The Test for Creative Thinking-Drawing Production (TCT-DP) is designed as an effective drawing-based instrument for measuring creative potential. Many studies report adaptation efforts in other cultures pointing out good psychometric properties of the instrument nonetheless revealing also some trouble spots. The present study includes adaptation…

  10. 40 CFR 1051.325 - What happens if an engine family fails the production-line testing requirements?

    Science.gov (United States)

    2010-07-01

    ... ENGINES AND VEHICLES Testing Production-Line Vehicles and Engines § 1051.325 What happens if an engine... for an engine family if it fails under § 1051.315. The suspension may apply to all facilities producing vehicles or engines from an engine family, even if you find noncompliant vehicles or engines only...

  11. 75 FR 47592 - Final Test Guideline; Product Performance of Skin-applied Insect Repellents of Insect and Other...

    Science.gov (United States)

    2010-08-06

    .... Crystal Dr., Arlington, VA. The hours of operation of this Docket Facility are from 8:30 a.m. to 4 p.m... has been working to revise this Product Performance Test Guideline since it was published as a... further strengthening the scientific and ethical conduct of this kind of research; these have been...

  12. Spiked environmental matrix for use as a reference material for gamma-ray spectrometry: Production and homogeneity test

    International Nuclear Information System (INIS)

    Sobiech-Matura, K.; Máté, B.; Altzitzoglou, T.

    2016-01-01

    The application of a spiking method for reference material production and its utilisation for a food matrix is presented. The raw rice powder was tested by means of γ-ray spectrometry and spiked with a "1"3"7Cs solution. The spiked material was mixed and tested for homogeneity. The future use of the rice powder reference material after the entire characterisation cycle will be for γ-ray spectrometry method validation. - Highlights: • Spiking blank substance with a traceable radioactive solution • Spiked reference material for γ-ray emitting radionuclides in food matrix • Results of the homogeneity tests are presented

  13. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Nekouei Shahraki

    2015-12-01

    Full Text Available The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation of test-stands delivering high calibration quality in single-shot calibration of fisheye surround-view cameras. This incorporates important geometric features from bundle-block calibration, delivers very high (sub-pixel calibration accuracy, makes possible a very fast calibration procedure (few seconds, and realizes autonomous calibration via machines. We have used the geometrical shape of a Spherical Helix (Type: 3D Spherical Spiral with special geometrical characteristics, having a uniform radius which corresponds to the uniform motion. This geometrical feature was mechanically realized using three dimensional truncated icosahedrons which practically allow the implementation of a spherical helix on multiple surfaces. Furthermore the test-stand enables us to perform many other important optical tests such as stray-light testing, enabling us to evaluate the certain qualities of the camera optical module.

  14. Synthesis H-Zeolite catalyst by impregnation KI/KIO3 and performance test catalyst for biodiesel production

    Science.gov (United States)

    Widayat, W.; Rizky Wicaksono, Adit; Hakim Firdaus, Lukman; Okvitarini, Ndaru

    2016-02-01

    The objective of this research is to produce H-catalyst catalyst that was impregnated with KI/KIO3. The catalyst was analyzed about surface area, X-Ray Diffraction (XRD) and performance test of catalyst for biodiesel production. An H-Zeolite catalyst was synthesized from natural zeolite with chemical treatment processing, impregnation KI/KIO3 and physical treatment. The results shows that the surface area of the catalyst by 27.236 m2/g at a concentration of 5% KI. XRD analysis shows peak 2-θ at 23.627o indicating that KI was impregnated on H-zeolite catalyst. The catalyst was tested in production of biodiesel using palm oil with conventional methods for 3 hour at temperature of 70-80 oC. The result for conversion Fatty Acid Methyl Ester (FAME) reached maximum value on 87.91% under production process using catalyst 5% KIO3-H zeolite.

  15. International Organization of Standardization (ISO) and Cambridge Filter Test (CFT) Smoking Regimen Data Comparisons in Tobacco Product Marketing Applications.

    Science.gov (United States)

    Chae, Changyu; Walters, Matthew J; Holman, Matthew R

    2017-07-01

    We investigated the differences in TNCO (tar, nicotine, and carbon monoxide) smoke yields generated under the International Organization of Standardization (ISO) and Federal Trade Commission (FTC) Cambridge Filter Test (CFT) smoking regimens. Twenty-nine commercial cigarette products from the US marketplace were acquired in 2015 and tested by measuring the TNCO smoke yields generated under these 2 nonintense smoking regimens. Data obtained demonstrated a linear relationship between the TNCO yields produced under the 2 smoking regimens (R 2 > 0.99). TNCO yields produced by each product were higher under the CFT smoking regimen than the ISO smoking regimen. We found that tar, nicotine, and carbon monoxide yields were consistently 10% to 13% higher under the CFT smoking regimen than under the ISO smoking regimen. This strong correlation indicates that the 2 smoking regimens can be used to apply a correlation correction to CFT TNCO data and allow its comparison to ISO TNCO data in tobacco product marketing applications.

  16. Potency determination of factor VIII and factor IX for new product labelling and postinfusion testing: challenges for caregivers and regulators.

    Science.gov (United States)

    Dodt, J; Hubbard, A R; Wicks, S J; Gray, E; Neugebauer, B; Charton, E; Silvester, G

    2015-07-01

    A workshop organized by the European Medicines Agency and the European Directorate for the Quality of Medicines and HealthCare was held in London, UK on November 28-29, 2013, to provide an overview of the current knowledge of the characterization of new factor VIII (FVIII) and factor IX (FIX) concentrates with respect to potency assays and testing of postinfusion material. The objective was to set the basis for regulatory authorities' discussion on the most appropriate potency assay for the individual products, and European Pharmacopoeia (Ph. Eur.) discussion on whether to propose revision of the Ph. Eur. monographs with respect to potency assays in the light of information on new FVIII and FIX concentrates. The workshop showed that for all products valid assays vs. the international concentrate standards were obtained and potency could be expressed in International Units. The Ph. Eur. chromogenic potency assay gave valid assay results which correlate with in vivo functionality of rFVIII products. For some modified rFVIII products and all modified rFIX products, one-stage clotting assay methods result in different potencies depending on the activated partial thromboplastin time reagent. As a consequence, monitoring of patients' postinfusion levels is challenging but it was pointed out that manufacturers are responsible for providing the users with appropriate information for use and laboratory testing of their product. Strategies to avoid misleading determination of patents' plasma levels, e.g. information on suitable assays, laboratory standards or correction factors were discussed. © 2015 John Wiley & Sons Ltd.

  17. Protection against productivity versus erosion vineyards. Testing of vegetal covers in slope crops

    International Nuclear Information System (INIS)

    Marques, M. J.; Ruiz-Colmenero, M.; Garcia-Munoz, S.; Cabello, F.; Munoz-Organero, G.; Perez-Jimenez, M. A.; Bienes, R.

    2009-01-01

    Temporary and permanent cover crops were used in three rain fed vineyards in the Center of Spain. They were sown in the middle of the strips to assess their ability to control erosion as well as their influence on grape production. Data from the year 2008 are compared with those obtained with traditional tillage treatment. The permanent cover formed by Brachypodium distachyon showed better ability to control erosion but it produced a decrease in production in young vines. barley and rye treatments were temporary covers, mowed in spring. They also reduced the erosion compared with the tillage however they did not appear to affect the vineyard production. (Author)

  18. BAGHOUSE FILTRATION PRODUCTS VERIFICATION TESTING, HOW IT BENEFITS THE BOILER BAGHOUSE OPERATOR

    Science.gov (United States)

    The paper describes the Environmental Technology Verification (ETV) Program for baghouse filtration products developed by the Air Pollution Control Technology Verification Center, one of six Centers under the ETV Program, and discusses how it benefits boiler baghouse operators. A...

  19. 75 FR 75289 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Dishwashers...

    Science.gov (United States)

    2010-12-02

    ... revisions: (1) The addition of a method to rate the efficiency of soil-sensing products; (2) the addition of... means and discharges to the plumbing drainage system.'' 10 CFR 430.2. Today's proposed amendments to the...

  20. Pilot testing of SHRP 2 reliability data and analytical products: Southern California.

    Science.gov (United States)

    2015-01-01

    The second Strategic Highway Research Program (SHRP 2) has been investigating the critical subject of travel time reliability for several years. As part of this research, SHRP 2 supported multiple efforts to develop products to evaluate travel time r...

  1. [Prediction of 137Cs accumulation in animal products in the territory of Semipalatinsk test site].

    Science.gov (United States)

    Spiridonov, S I; Gontarenko, I A; Mukusheva, M K; Fesenko, S V; Semioshkina, N A

    2005-01-01

    The paper describes mathematical models for 137Cs behavior in the organism of horses and sheep pasturing on the bording area to the testing area "Ground Zero" of the Semipalatinsk Test Site. The models are parameterized on the base of the data from an experiment with the breeds of animals now commonly encountered within the Semipalatinsk Test Site. The predictive calculations with the models devised have shown that 137Cs concentrations in milk of horses and sheep pasturingon the testing area to "Ground Zero" can exceed the adopted standards during a long period of time.

  2. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    International Nuclear Information System (INIS)

    1987-10-01

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH) has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided

  3. Radioactively labelled substances for in vivo and in vitro tests from the time of their production up to their use in nuclear medicine

    International Nuclear Information System (INIS)

    Riccato, M.T.

    1976-01-01

    Most important production steps and control tests applied to radionuclides and radioactive labelled compounds used in nuclear medicine are described. Radiopharmaceutical products are subdivided in products for therapy and for in vivo and in vitro diagnostics tests. (orig./HP) [de

  4. Test/QA Plan For Verification Of Anaerobic Digester For Energy Production And Pollution Prevention

    Science.gov (United States)

    The ETV-ESTE Program conducts third-party verification testing of commercially available technologies that improve the environmental conditions in the U.S. A stakeholder committee of buyers and users of such technologies guided the development of this test on anaerobic digesters...

  5. 40 CFR 1045.345 - What production-line testing records must I send to EPA?

    Science.gov (United States)

    2010-07-01

    ... must I send to EPA? 1045.345 Section 1045.345 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... nonroutine adjustment, modification, repair, preparation, maintenance, or test for the test engine if you did... sample-size calculation required in § 1045.310 for each engine family. (9) Report on each failed engine...

  6. 40 CFR 1048.345 - What production-line testing records must I send to EPA?

    Science.gov (United States)

    2010-07-01

    ... must I send to EPA? 1048.345 Section 1048.345 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... nonroutine adjustment, modification, repair, preparation, maintenance, or test for the test engine if you did... the sample-size calculation required in § 1048.310 for each engine family. (9) Report on each failed...

  7. 75 FR 42579 - Energy Conservation Program for Consumer Products: Test Procedure for Microwave Ovens; Repeal of...

    Science.gov (United States)

    2010-07-22

    ... provided in paragraph (i)(2) of this section, for each basic model of conventional cooking tops, and... the cooking efficiency test procedure for microwave ovens under the Energy Policy and Conservation Act (EPCA). DOE has determined that the microwave oven test procedure to measure the cooking efficiency does...

  8. 75 FR 35282 - Third Party Testing for Certain Children's Products; Infant Walkers: Requirements for...

    Science.gov (United States)

    2010-06-21

    ... requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing... to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and... tested by a third party conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA...

  9. 75 FR 42611 - Energy Conservation Program for Consumer Products: Test Procedure for Microwave Ovens

    Science.gov (United States)

    2010-07-22

    ... for Microwave Ovens AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy... current active mode provisions in its test procedure for microwave ovens do not produce accurate and... concerns with the DOE microwave oven cooking efficiency test procedure. Elsewhere in today's Federal...

  10. Personality testing and workplace training : Exploring stakeholders, products and purpose in Western Europe

    NARCIS (Netherlands)

    Lundgren, H.; Kroon, B.; Poell, R.F.

    2017-01-01

    Purpose The purpose of this paper is to explore how and why personality tests are used in workplace training. This research paper is guided by three research questions that inquire about the role of external and internal stakeholders, the value of psychometric and practical considerations in test

  11. 76 FR 18105 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Central Air...

    Science.gov (United States)

    2011-04-01

    ... the lab-added transformer. Id. Under this proposal, the instrument used to measure the electrical... the low-voltage transformer used when testing coil-only residential central air conditioners and heat... the Low-Voltage Transformer Used When Testing Coil- Only Central Air Conditioners and Heat Pumps and...

  12. The marketing of health products, with special reference to do-it-yourself tests

    NARCIS (Netherlands)

    Gevers, Sjef

    2003-01-01

    At a rapid pace, in vitro diagnostic medical devices are being developed to detect risk factors for disease; to a growing extent, these test kits are also directly marketed to the public for use at home. While at first sight serving a good cause, self testing may have considerable drawbacks relating

  13. 78 FR 6232 - Energy Conservation Program: Test Procedures for Conventional Cooking Products With Induction...

    Science.gov (United States)

    2013-01-30

    ... blocks currently specified in Appendix I reflect consumer cooking behavior. DOE is not aware of... tests may better reflect actual consumer behavior for cooking tops, and invites comment on whether water... consumer use data, and given the potential non-representative thermal behavior of a test block in which a...

  14. 76 FR 65616 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Central Air...

    Science.gov (United States)

    2011-10-24

    ... pages 2- 3. Both the American Heating and Refrigeration Institute (AHRI) and Trane stated that the... untested split system combinations for SEER and HSPF. \\4\\ ARMs are computer simulations used to rate... procedure, which is detailed in section 0, and comprises whole system testing, not testing or simulation of...

  15. Integrated automatic non-destructive testing in industrial production and in the operation of technical plant

    International Nuclear Information System (INIS)

    Hoeller, P.

    1989-01-01

    The article deals with non-destructive testing (NDT) in automated manufacture and in the automated operation of industrial plant. In both areas of application, the tests are coupled to the process (real time operation) and the results are used for the control of manufacture or of the course of the process. The control process can be coupled to the process in open loop or closed loop. The subject is explained by the following examples: 1) Automated testing of sheets in a steelworks. 2) Automatic NDT on machine parts in tempering and machining by the 3MA system (3MA: micro-magnetic, multi-parameter, micro-structure and stress analysis). 3) Automated ultrasonic testing in manufacture and in the operation of plants with the ALOK data collection and processing system (ALOK: amplitude, running time, location curves). 4) Automated wheel running surface test on Intercity experimental train, and 5) automated level measurement on BWR pressure vessels. (orig./MM) [de

  16. Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard

    Science.gov (United States)

    Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly

    2017-08-01

    The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period

  17. Analysis of differential method for compensating fluctuations in product thickness when radiometric testing

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Kvasnitsa, M.S.

    1979-01-01

    Given are the estimates of information capabilities of the differential method for measuring radiation flux in radiation defectoscopy as well as efficiency of application of automatic radiation facilities to control taking into account the statistical regularities of product thickness fluctuations. Dependences of signal to noise ratio on the regularities of product thickness fluctuations have been found and optimization, on this basis, of the design and parameters of processing instrumentation was carried out. It is shown, that with 60-80 mm interval of product thickness fluctuations correlation (welded joints) it is expedient to use two radiation beams with their crossing on a mean product plane. When the interval of correlation of thickness fluctuations is great it is effective to use the geometry of radioscopy with parallel radiation beams. This permits to use only one radiation source without significant reducing the compensation efficiency, that in most cases simplifies the development and application of radiometric systems. Thus the efficiency of applying the differential method for radiation beam detection to compensate product thickness fluctuations is primarily determined by statistical regularities of the given fluctuations. The account of the regularities in the development of the processing instrumentation results in the most complete extraction of useful information, containing in the radiation beams being detected

  18. Application of high-resolution melting analysis for authenticity testing of valuable Dendrobium commercial products.

    Science.gov (United States)

    Dong, Xiaoman; Jiang, Chao; Yuan, Yuan; Peng, Daiyin; Luo, Yuqin; Zhao, Yuyang; Huang, Luqi

    2018-01-01

    The accurate identification of botanical origin in commercial products is important to ensure food authenticity and safety for consumers. The Dendrobium species have long been commercialised as functional food supplements and herbal medicines in Asia. Three valuable Dendrobium species, namely Dendrobium officinale, D. huoshanense and D. moniliforme, are often mutually adulterated in trade products in pursuit of higher profit. In this paper, a rapid and reliable semi-quantitative method for identifying the botanical origin of Dendrobium products in terminal markets was developed using high-resolution melting (HRM) analysis with specific primer pairs to target the trnL-F region. The HRM analysis method detected amounts of D. moniliforme adulterants as low as 1% in D. huoshanense or D. officinale products. The results have demonstrated that HRM analysis is a fast and effective tool for the differentiation of these Dendrobium species both for their authenticity as well as for the semi-quantitative determination of the purity of their processed products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. Fission product aerosol removal test by containment spray under accident management conditions (3)

    International Nuclear Information System (INIS)

    Watanabe, Atsushi; Nagasaka, Hideo; Yokobori, Seiichi; Akinaga, Makoto

    2000-01-01

    In order to demonstrate the effective FP aerosol removal by containment spray under Japanese AM conditions, two system integral tests and two separate effect tests were carried out using a full-height simulation test facility. In case of PWR LOCA, aerosol concentration in the upper containment vessel decreased even under low spray flow rate. In case of BWR LOCA with water injection into RPV, the aerosol concentration in the entire vessel also decreased rapidly after aerosol supply stopping. In both cases, the removal rate estimated from the NUREG-1465 was coincided with test results. The aerosol washing effect by spray was confirmed to be predominant by conducting suppression chamber isolation test. It turned out that the effect of aerosol solubility and density on aerosol removal by spray was quite small by conducting insoluble aerosol injection test. After the modification of aerosol removal model by the spray and hygroscopic aerosol model in original MELCOR 1.8.4, calculated aerosol concentration transient in the containment vessel agreed well with the test data. (author)

  20. Full-scale testing, production and cost analysis data for the advanced composite stabilizer for Boeing 737 aircraft. Volume 1: Technical summary

    Science.gov (United States)

    Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parsons, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.

    1983-01-01

    The full scale ground test, ground vibration test, and flight tests conducted to demonstrate a composite structure stabilizer for the Boeing 737 aircraft and obtain FAA certification are described. Detail tools, assembly tools, and overall production are discussed. Cost analyses aspects covered include production costs, composite material usage factors, and cost comparisons.

  1. OPEC's production under fluctuating oil prices. Further test of the target revenue theory

    International Nuclear Information System (INIS)

    Ramcharran, H.

    2001-01-01

    Oil production cutbacks in recent years by OPEC members to stabilize price and to increase revenues warrant further empirical verification of the target revenue theory (TRT). We estimate a modified version of Griffin (1985) target revenue model using data from 1973 to 2000. The sample period, unlike previous investigations, includes phases of both price increase (1970s) and price decrease (1980s-1990s), thus providing a better framework for examining production behavior. The results, like the earlier study, are not supportive of the strict version of the TRT, however, evidence (negative and significant elasticity of supply) of the partial version are substantiated. Further empirical estimates do not support the competitive pricing model, hypothesizing a positive elasticity of supply. OPEC's loss of market share and the drop in the share of oil-based energy should signal an adjustment in pricing and production strategies

  2. Experimental tests of the production process of Mo-99 fission in the hot cell

    International Nuclear Information System (INIS)

    Sanchez M, V.; Lopez C, R.

    1991-12-01

    The production method of 99 Mo of fission obtains to this with a specific activity of several orders of great magnitude to the one obtained by other methods (as that of irradiation of a target constituted by an alloy or that of irradiation with neutrons of targets of molybdenum of natural isotopic composition or enriched with 98 Mo) and perhaps the most important it is that by this method hundred of Ci of 99 Mo can be obtained by production process. The development of the production process of 99 Mo of fission, is closely linked with the development of techniques for the handling of high radioactivities, particularly the handling of radioactive gases, also with the deposit and elimination of radioactive wastes and with the construction of safety targets for its irradiation in a nuclear reactor. (Author)

  3. Corrosion behavior of environmental assessment glass in product consistency tests of extended duration

    International Nuclear Information System (INIS)

    Bates, J.K.; Buck, E.C.; Ebert, W.L.; Luo, J.S.; Tam, S.W.

    1998-01-01

    We have conducted static dissolution tests to study the corrosion behavior of the Environmental Assessment (EA) glass, which is the benchmark glass for high-level waste glasses being produced at US Department of Energy facilities. These tests were conducted to evaluate the behavior of the EA glass under the same long-term and accelerated test conditions that are being used to evaluate the corrosion of waste glasses. Tests were conducted at 90 C in a tuff groundwater solution at glass surface area/solution volume (WV) ratios of about 2000 and 20,000 m -1 . The glass dissolved at three distinct dissolution rates in tests conducted at 2000 m -1 . Based on the release of boron, dissolution within the first seven days occurred at a rate of about 0.65 g/(m 2 · d). The rate between seven and 70 days decreased to 0.009 g/(m 2 · d). An increase in the dissolution rate occurred at longer times after the precipitation of zeolite phases analcime, gmelinite, and an aluminum silicate base. The dissolution rate after phase formation was about 0.18 g/(m 2 · d). The formation of the same zeolite alteration phases occurred after about 20 days in tests at 20,000 m - . The average dissolution rate over the first 20 days was 0.5 g/(m 2 · d) and the rate after phase formation was about 0.20 g/(m 2 · d). An intermediate stage with a lower rate was not observed in tests at 20,000 m -1 . The corrosion behavior of EA glass is similar to that observed for other high-level waste glasses reacted under the same test conditions. The dissolution rate of EA glass is higher than that of other high-level waste glasses both in 7-day tests and after alteration phases form

  4. Eddy current testing instruments manufactured by the production unit of the Brno Technical University

    International Nuclear Information System (INIS)

    Fiala, I.

    1989-01-01

    Three materials testing machines are described. The ECTER general-purpose machine for materials testing in diagnostics of selected components of nuclear power plants can be used in detection and monitoring of defects of non-ferromagnetic tubes in heat exchangers using an immersion probe for crack, wall thickness and corrosion detection. The instrument for inspection of pipe welding joints, DEST-1, is the sensor of the control system of a welder for axially welded pipes. The third instrument, a device for detection of surface defects in metallic materials is used for testing steel rod materials. It is used in screw mills. (M.D.). 2 figs

  5. Tests of QCD using jets, bosons plus jets, and top quark production at colliders

    CERN Document Server

    Cossutti, Fabio

    2017-01-01

    Quantum Chromodynamics (QCD) is actively studied at present collidersusing several physics signatures as probes. Results from measurementsdone at LHC, but also from the legacy analyses of Tevatron and HERAdata, are discussed. Jets are the main tool for such investigation, asexperimental evidence for emission of gluons or quark production inQCD-dominated processes. Jet production in multijet events or inassociation with vector bosons is discussed. The investigation of theproduction of heavy quarks, and in particular of the top quark, is ofspecial importance both for the physics implications in the search fornew phenomena and for its unique characteristics from the QCD point ofview.

  6. Installation and testing of a hospital-based cyclotron for radiation therapy and isotope production

    International Nuclear Information System (INIS)

    Almond, P.R.; Marbach, J.R.; Otte, V.A.

    1983-01-01

    A hospital based cyclotron is under installation at The University of Texas M.D. Anderson Hospital in Houston. This machine will be used for the production of radioactive isotopes and for the generation of neutrons for the radiotherapy treatment of cancer. It is a Cyclotron Corporation CP-42 negative proton accelerator. For neutron production the protons are transported through an isocentrically mounted beam transport system that can be rotated around the patient. The shielding requirements of this facility will be described as will the initial measurements on the characteristics of the neutron beam

  7. Productivity

    DEFF Research Database (Denmark)

    Spring, Martin; Johnes, Geraint; Hald, Kim Sundtoft

    Productivity is increasingly critical for developed economies. It has always been important: as Paul Krugman puts it, “Productivity isn’t everything, but in the long run it is almost everything. A country’s ability to improve its standard of living over time depends almost entirely on its ability...... to raise its output per worker”(Krugman, 1994). Analyses of productivity have, by and large, been the preserve of economists. Operations Management (OM) is rooted in a similar concern for the efficient use of scarce resources; Management Accounting (MA) is concerned with the institutionalised measurement...... and management of productivity. Yet the three perspectives are rarely connected. This paper is a sketch of a literature review seeking to identify, contrast and reconcile these three perspectives. In so doing, it aims to strengthen the connections between policy and managerial analyses of productivity....

  8. A test trial irradiation of natural rubber latex on large scale for the production of examination gloves in a production scale

    International Nuclear Information System (INIS)

    Devendra, R.; Kulatunge, S.; Chandralal, H.N.K.K.; Kalyani, N.M.V.; Seneviratne, J.; Wellage, S.

    1996-01-01

    Radiation Vulcanization of natural rubber latex has been developed extensively through various research and development programme. During these investigations many data was collected and from these data it was proved that radiation vulcanized natural rubber latex (RVNRL) can be used as a new material for industry (RVNRL symposium 1989; Makuuchi IAEA report). This material has been extensively tested in making of dipped goods and extruded products. However these investigations were confined only to laboratory experiments and these experiments mainly reflected material properties of RVNRL and only a little was observed about its behavior in actual production scale operation. The present exercise was carried out mainly to study the behavior of the material in production scale by irradiating latex on a large scale and producing gloves in a production scale plant. It was found that RVNRL can be used in conventional glove plants without making major alteration to the plant. Quality of the gloves that were produced using RVNRL is acceptable. It was also found that the small deviation of vulcanization dose will affect the crosslinking density of films. This will drastically reduce the tensile strength of the film. Crosslinking density or pre-vulcanized relax modulus (PRM) at 100% is a reliable property to control the pre vulcanization of latex by radiation

  9. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.

    1957-10-01

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  10. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    Science.gov (United States)

    Brombin, M.; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R.; Schiesko, L.

    2014-11-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors' holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

  11. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    International Nuclear Information System (INIS)

    Brombin, M.; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R.; Schiesko, L.

    2014-01-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns

  12. Test system for the production of the Atlas Tile Calorimeter front-end electronics

    International Nuclear Information System (INIS)

    Calvet, David

    2004-01-01

    The Atlas hadronic Tile Calorimeter front-end electronics is fully included in the so-called 'super-drawers'. The 256 super-drawers needed for the entire calorimeter are assembled and extensively tested in Clermont-Ferrand before being sent to CERN to be inserted in the calorimeter modules. A mobile system has been developed to perform a complete test of the super-drawers during their insertion

  13. Project Rio Blanco definition plan. Additional formation evaluation and production testing

    International Nuclear Information System (INIS)

    1975-09-01

    Since the multiple Rio Blanco detonation three reentry wells have been drilled for test purposes: RB-E-01 (Emplacement Well); RB-AR-2 (Alternate Reentry Well); and RB-U-4 (Formation Evaluation Well). Additional testing in all these wells is now required to resolve some remaining technical questions. A plan describing the procedures, methods, responsibilities, and scheduling of the field operations is presented

  14. Photocatalysis applied to concrete products - Part 1: Principles and test procedure

    NARCIS (Netherlands)

    Hunger, M.; Hüsken, G.; Brouwers, H.J.H.

    2008-01-01

    This three-part article addresses the photocatalytic properties of concrete containing titanium dioxide (TiO2). In the first part, the evaluation of the air purifying abilities of the final concrete product is described. A setup for measuring the performance of photocatalytic active concrete

  15. Competitive drivers and international plant configuration strategies: A product level test

    NARCIS (Netherlands)

    Belderbos, R.A.; Sleuwaegen, L.

    2005-01-01

    We analyze the determinants of the decision to invest abroad and the choice of spatial configurations of overseas plants for 120 Japanese firms active in 36 well-defined electronic product markets. We find that key competitive drivers at the firm and industry levels have a critical impact on the

  16. Test of the Okubo-Zweig-Iizuka rule in phi production

    International Nuclear Information System (INIS)

    Etkin, A.; Foley, K.J.; Goldman, J.H.; Love, W.A.; Morris, T.W.; Ozaki, S.; Platner, E.D.; Saulys, A.C.; Wheeler, C.D.; Willen, E.H.; Lindenbaum, S.J.; Kramer, M.A.; Mallik, U.

    1978-01-01

    We have measured the reaction π - p → K + K - K + K - n at 22.6 GeV/c and defect strong phi signals in the K + K - effective-mass plots. We do not observe the expected Okubo-Zweig-Iizuka--rule suppression of the phiphin final state and conclude that the rule is working poorly in the observed production processes

  17. Chromatography in authenticity and traceability tests of vegetable oils and dairy products: a review

    Czech Academy of Sciences Publication Activity Database

    Cserháti, T.; Forgács, E.; Deyl, Zdeněk; Mikšík, Ivan

    2005-01-01

    Roč. 19, č. 3 (2005), s. 183-190 ISSN 0269-3879 Grant - others:CZ-HU(CZ) Cooperation programme Institutional research plan: CEZ:AV0Z50110509 Keywords : chromatography * dairy products * vegetable oils Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.218, year: 2005

  18. Exploring the cognitive and affective bases of online purchase intentions : a hierarchical test across product types

    NARCIS (Netherlands)

    Verhagen, Tibert; Bloemers, Daniel

    2017-01-01

    Whereas there is ample e-commerce research on how online store beliefs and consumer online affective states may influence online purchase intentions, no research so far has examined whether the hierarchy of effects between these concepts differs across product types. In this study, we fill this

  19. Testing Students under Cognitive Capitalism: Knowledge Production of Twenty-First Century Skills

    Science.gov (United States)

    Morgan, Clara

    2016-01-01

    Scholars studying the global governance of education have noted the increasingly important role corporations play in educational policy making. I contribute to this scholarship by examining the Assessment and Teaching of twenty-first century skills (ATC21S™) project, a knowledge production apparatus operating under cognitive capitalism. I analyze…

  20. Development and testing of synthetic riprap constructed from coal combustion products (CCPs).

    Science.gov (United States)

    2014-07-01

    Even with an increase in the amount of coal combustion products (CCPs) used in concrete con-struction, soil stabilization, and other : applications, the coal power industry must dispose of a sig-nificant amount of fly ash and bottom ash. One potentia...

  1. Exposure testing of fasteners in preservative treated wood: Gravimetric corrosion rates and corrosion product analyses

    Energy Technology Data Exchange (ETDEWEB)

    Zelinka, Samuel L., E-mail: szelinka@fs.fed.u [USDA Forest Products Laboratory, One Gifford Pinchot Drive, Madison, WI 53726 (United States); Sichel, Rebecca J. [College of Engineering, University of Wisconsin, Madison, WI 53706 (United States); Stone, Donald S. [Department of Materials Science and Engineering, College of Engineering, University of Wisconsin, Madison, WI 53706 (United States)

    2010-12-15

    Research highlights: {yields} The composition of the corrosion products was similar for the nail head and shank. {yields} Reduced copper was not detected on any of the fasteners. {yields} Measured corrosion rates were between 1 and 35 {mu}m year{sup -1}. - Abstract: Research was conducted to determine the corrosion rates of metals in preservative treated wood and also understand the mechanism of metal corrosion in treated wood. Steel and hot-dip galvanized steel fasteners were embedded in wood treated with one of six preservative treatments and exposed to 27 {sup o}C at 100% relative humidity for 1 year. The corrosion rate was determined gravimetrically and the corrosion products were analyzed with scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. Although the accepted mechanism of corrosion in treated wood involves the reduction of cupric ions from the wood preservative, no reduced copper was found on the corrosion surfaces. The galvanized corrosion products contained sulfates, whereas the steel corrosion products consisted of iron oxides and hydroxides. The possible implications and limitations of this research on fasteners used in building applications are discussed.

  2. 77 FR 64566 - Market Test of Experimental Product-Metro Post

    Science.gov (United States)

    2012-10-22

    ... states that online e-commerce companies and retailers have realized the power of online shipping... is specifically designed for online e-commerce companies and associated retailers to deliver products... into relationships with qualifying online e-commerce companies to offer same-day local delivery. Id. at...

  3. The field-tested and grounded technological rule as product of mode 2 management research

    NARCIS (Netherlands)

    Aken, van J.E.

    2004-01-01

    The relevance problem of academic management research in organization and management is an old and thorny one. Recent discussions on this issue have resulted in proposals to use more Mode 2 knowledge production in our field. These discussions focused mainly on the process of research itself and less

  4. Cool products for building envelope - Part I: Development and lab scale testing

    NARCIS (Netherlands)

    Revel, G.M.; Martarelli, M.; Emiliani, M.; Gozalbo, A.; Orts, M.J.; Bengochea, M.T.; Guaita Delgado, L.; Gaki, A.; Katsiapi, A.; Taxiarchou, M.; Arabatzis, I.; Fasaki, I.; Hermanns, S.

    2014-01-01

    The paper describes the methodology followed for the development of new cool products in order to widen the range of existing solutions both including coloured (even dark) materials and extending the application also to building vertical components. Cool coloured ceramic tiles and acrylic paints for

  5. 75 FR 29823 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...

    Science.gov (United States)

    2010-05-27

    .... This NOPR also discusses the proposed treatment of combination wine storage-freezer products that were.... Combination Wine Storage-Freezer Units C. Establishing New Appendices A and B, and Compliance Date for the... rule published in the Federal Register on September 14, 1977. 42 FR 46140. Industry representatives...

  6. Cellular regulation of basal and FSH-stimulated cyclic AMP production in irradiated rat testes

    International Nuclear Information System (INIS)

    Kangasniemi, M.; Kaipia, A.; Toppari, J.; Mali, P.; Huhtaniemi, I.; Parvinen, M.

    1990-01-01

    Basal and follicle-stimulating hormone (FSH)-stimulated cyclic AMP (cAMP) productions by seminiferous tubular segments from irradiated adult rats were investigated at defined stages of the epithelial cycle when specific spermatogenic cells were low in number. Seven days post-irradiation, depletion of spermatogonia did not influence the basal cAMP production, but FSH response increased in stages II-VIII. Seventeen days post-irradiation when spermatocytes were low in number, there was a small increase in basal cAMP level in stages VII-VIII and FSH-stimulated cAMP production increased in stages VII-XII and XIII-I. At 38 days when pachytene spermatocytes and round spermatids (steps 1-6) were low in number, a decreased basal cAMP production was measured in stages II-VI and IX-XII. FSH-stimulated cAMP output increased in stages VII-XII but decreased in stages II-VI. At 52 days when all spermatids were low in number, basal cAMP levels decreased in all stages of the cycle, whereas FSH response was elevated only in stages VII-XII. All spermatogenic cell types seem to have an effect on cAMP production by the seminiferous tubule in a stage-specific fashion. Germ cells appear to regulate Sertoli cell FSH response in a paracrine way, and a part of cAMP may originate from spermatids stimulated by an unknown FSH-dependent Sertoli cell factor. The FSH-dependent functions may control such phenomena as spermatogonial proliferation, final maturation of spermatids, and onset of meiosis

  7. Comparative evaluation of pyrogens tests in pharmaceutical products Avaliação comparativa de testes de pirogênios em produtos farmacêuticos

    Directory of Open Access Journals (Sweden)

    Rosimar L. Silveira

    2004-06-01

    Full Text Available A comparison of methodologies for detection of pyrogens in pharmaceutical products was performed. The rabbit pyrogen test was optimized and the dose-response curve was obtained for the 2nd International Standard for bacterial endotoxins, establishing 13.81 EU/mL/kg as the concentration of endotoxin necessary to induce a temperature rise of 0.5ºC. The 0.5ºC cut-off was shown to give results that were more compatible with the pyrogenic doses for humans. The Limulus amoebocyte lysate test (LAL was standardized with gel-clot and chromogenic endpoints, and used for the comparative evaluation of pharmaceutical products showing good agreement. The use of beta-glucan-reactive and non-reactive LAL reagents identified some products with false-positive results. The interference test was carried out and the specifications validated for some new products as the maximum valid dilution. The results emphasized the importance and limitations of the assays recommended for the evaluation of purity and quality control of parenteral medicinal products, improving the existing methodologies in the context of reduction and replacement in the use of animal models.Realizou-se a comparação de metodologia para avaliação de pirogênios em produtos farmacêuticos. Otimizou-se o teste da hipertermia em coelhos elaborando a curva dose-resposta com o 2º Padrão Internacional de endotoxinas bacterianas, com base na qual determinou-se a concentração de 13,81 UE/mL por kg de peso corporal, necessária para produzir aumento de temperatura de 0,5ºC. Observou-se que o limite de 0,5ºC forneceu resultados comparáveis com as doses pirogênicas para o homem. Padronizou-se o teste do lisado de amebócitos do Limulus (LAL com determinação do ponto final cromogênico e por geleificação, que foram utilizados para a avaliação de produtos farmacêuticos obtendo-se resultados concordantes. Avaliaram-se as respostas de reagentes LAL reativos e não-reativos a beta

  8. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  9. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  10. Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products

    DEFF Research Database (Denmark)

    Frosch, Peter J; Rastogi, Suresh C; Pirker, Claudia

    2005-01-01

    order was the same for both FM II concentrations: hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) > citral > farnesol > citronellol > alpha-hexyl-cinnamic aldehyde (AHCA). No unequivocally positive reaction to coumarin was observed. Lyral) was the dominant individual constituent, with positive...... and a positive reaction to either 28% or 14% FM II but a negative reaction to FM I. Analysis with GC-MS in a total of 24 products obtained from 12 patients showed at least 1-5 individual constituents per product: Lyral (79.2%), citronellol (87.5%), AHCA (58.3%), citral (50%) and coumarin (50%). The patients were...... patch test positive to Lyral, citral and AHCA. In conclusion, patients with a certain fragrance history and a negative reaction to FM I can be identified by FM II. Testing with individual constituents is positive in about 50% of cases reacting to either 14% or 28% FM II....

  11. Optimized Gen-II FeCrAl cladding production in large quantity for campaign testing

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yukinori [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sun, Zhiqian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pint, Bruce A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, Kurt A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-06-03

    There are two major objectives in this report; (1) to optimize microstructure control of ATF FeCrAl alloys during tube drawing processes, and (2) to provide an update on the progress of ATF FeCrAl tube production via commercial manufacturers. Experimental efforts have been made to optimize the process parameters balancing the tube fabricability, especially for tube drawing processes, and microstructure control of the final tube products. Lab-scale sheet materials of Gen II FeCrAl alloys (Mo-containing and Nb-containing FeCrAl alloys) were used in the study, combined with a stepwise warm-rolling process and intermediate annealing, aiming to simulate the tube drawing process in a commercial tube manufacturer. The intermediate annealing at 650ºC for 1h was suggested for the tube-drawing process of Mo-containing FeCrAl alloys because it successfully softened the material by recovering the work hardening introduced through the rolling step, without inducing grain coarsening due to recrystallization. The final tube product is expected to have stabilized deformed microstructure providing the improved tensile properties with sufficient ductility. Optimization efforts on Nb-containing FeCrAl alloys focused on the effect of alloying additions and annealing conditions on the stability of deformed microstructure. Relationships between the second-phase precipitates (Fe2Nb-Laves phase) and microstructure stability are discussed. FeCrAl tube production through commercial tube manufacturers is currently in progress. Three different manufacturers, Century Tubes, Inc. (CTI), Rhenium Alloys, Inc. (RAI), and Superior Tube Company, Inc. (STC), are providing capabilities for cold-drawing, warm-drawing, and HPTR cold-pilgering, respectively. The first two companies are currently working on large quantity tube production (expected 250 ft length) of Gen I model FeCrAl alloy (B136Y3, at CTI) and Gen II (C35M4, at RAI), with the process parameters obtained from the experimental

  12. Area balance method for calculation of air interchange in fire-resesistance testing laboratory for building products and constructions

    Directory of Open Access Journals (Sweden)

    Sargsyan Samvel Volodyaevich

    2014-09-01

    Full Text Available Fire-resistance testing laboratory for building products and constructions is a production room with a substantial excess heat (over 23 W/m . Significant sources of heat inside the aforementioned laboratory are firing furnace, designed to simulate high temperature effects on structures and products of various types in case of fire development. The excess heat production in the laboratory during the tests is due to firing furnaces. The laboratory room is considered as an object consisting of two control volumes (CV, in each of which there may be air intake and air removal, pollutant absorption or emission. In modeling air exchange conditions the following processes are being considered: the processes connected with air movement in the laboratory room: the jet stream in a confined space, distribution of air parameters, air motion and impurity diffusion in the ventilated room. General upward ventilation seems to be the most rational due to impossibility of using local exhaust ventilation. It is connected with the peculiarities of technological processes in the laboratory. Air jets spouted through large-perforated surface mounted at the height of 2 m from the floor level, "flood" the lower control volume, entrained by natural convective currents from heat sources upward and removed from the upper area. In order to take advantage of the proposed method of the required air exchange calculation, you must enter additional conditions, taking into account the provision of sanitary-hygienic characteristics of the current at the entrance of the service (work area. Exhaust air containing pollutants (combustion products, is expelled into the atmosphere by vertical jet discharge. Dividing ventilated rooms into two control volumes allows describing the research process in a ventilated room more accurately and finding the air exchange in the lab room during the tests on a more reasonable basis, allowing to provide safe working conditions for the staff without

  13. Preliminary scoping safety analyses of the limiting design basis protected accidents for the Fast Flux Test Facility tritium production core

    International Nuclear Information System (INIS)

    Heard, F.J.

    1997-01-01

    The SAS4A/SASSYS-l computer code is used to perform a series of analyses for the limiting protected design basis transient events given a representative tritium and medical isotope production core design proposed for the Fast Flux Test Facility. The FFTF tritium and isotope production mission will require a different core loading which features higher enrichment fuel, tritium targets, and medical isotope production assemblies. Changes in several key core parameters, such as the Doppler coefficient and delayed neutron fraction will affect the transient response of the reactor. Both reactivity insertion and reduction of heat removal events were analyzed. The analysis methods and modeling assumptions are described. Results of the analyses and comparison against fuel pin performance criteria are presented to provide quantification that the plant protection system is adequate to maintain the necessary safety margins and assure cladding integrity

  14. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers procedures for determining water absorption, bulk density, apparent porosity, and apparent specific gravity of fired unglazed whiteware products. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Design and production of a novel sand materials strength testing machine for foundry applications

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Hansen, K. S.; Tiedje, Niels Skat

    2012-01-01

    testing machine was designed and built for both green sand and chemically-bonded sand materials. This machine measures and presents the loading response as a force-displacement profile from which the mechanical properties of the moulding materials can be deduced. The system was interfaced to a computer......In the foundry, existing strength testing machines are used to measure only the maximum fracture strength of mould and core materials. With traditionally used methods, the loading history to ascertain deformation of the material is not available. In this paper, a novel moulding material strength...... with a commercial PC based-control and data acquisition software. The testing conditions and operations are specified in the user interface and the data acquisition is made according to specifications. The force and displacements were calibrated to ensure consistency and reliability of the measurement data...

  16. Development of a validation test for self-reported abstinence from smokeless tobacco products: preliminary results

    International Nuclear Information System (INIS)

    Robertson, J.B.; Bray, J.T.

    1988-01-01

    Using X-ray fluorescence spectrometry, 11 heavy elements at concentrations that are easily detectable have been identified in smokeless tobacco products. These concentrations were found to increase in cheek epithelium samples of the user after exposure to smokeless tobacco. This feasibility study suggests that the level of strontium in the cheek epithelium could be a valid measure of recent smokeless tobacco use. It also demonstrates that strontium levels become undetectable within several days of smokeless tobacco cessation. This absence of strontium could validate a self-report of abstinence from smokeless tobacco. Finally, the X-ray spectrum of heavy metal content of cheek epithelium from smokeless tobacco users could itself provide a visual stimulus to further motivate the user to terminate the use of smokeless tobacco products

  17. Diffractive Production of Jets and Weak Bosons, and Tests of Hard-Scattering Factorization

    CERN Document Server

    Alvero, L; Terrón, J; Whitmore, J; Alvero, Lyndon; Collins, John C.; Terron, Juan; Whitmore, Jim

    1999-01-01

    We extract diffractive parton densities from diffractive, deep inelastic (DIS) ep data from the ZEUS experiment. Then we use these fits to predict the diffractive production of jets and of W's and Z's in p\\bar p collisions at the Tevatron. Although the DIS data require a hard quark density in the pomeron, we find fairly low rates for the Tevatron processes (a few percent of the inclusive cross section). This results from the combined effects of Q^{2} evolution and of a normalization of the parton densities to the data. The calculated rates for W production are generally consistent with the preliminary data from the Tevatron. However, the jet data from CDF with a ``Roman pot'' trigger are substantially lower than the results of our calculations; if confirmed, this would signal a breakdown of hard-scattering factorization.

  18. Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1998-01-01

    This International Standard deals with safety aspects of power transformers, power supplies, reactors and similar products such as electrical, thermal and mechanical safety. This standard covers the following types of dry-type transformers, power supplies, including switch mode power supplies, and reactors, the windings of which may be encapsulated or non-encapsulated. It has the status of a group safety publication in accordance with IEC Guide 104.

  19. Testing J/PSI production mechanisms in B -> J/PSI + X

    CERN Document Server

    Ko, P W; Song, H S

    1999-01-01

    Using the color evaporation model (CEM), we consider the decay rate of B -> J/PSI + X and the polarization of J/PSI therein, and we compare the results with the data and with the predictions by the nonrelativistic quantum chromodynamics (NRQCD) approach. In the CEM, we use the input parameter determined from photo/hadro productions of J/PSI, and we find that it is difficult to make the CEM predictions confront with the CLEO data on these observables.

  20. Technical protocol for laboratory tests of transformation of veterinary medicinal products and biocides in liquid manures. Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzig, Robert [Technische Univ. Braunschweig (Germany). Inst. fuer Oekologische Chemie und Abfallanalytik

    2010-07-15

    The technical protocol under consideration describes a laboratory test method to evaluate the transformation of chemicals in liquid bovine and pig manures under anaerobic conditions and primarily is designed for veterinary medicinal products and biocides. The environmentally relevant entry routes into liquid manures occur via urine and feces of cattle and pigs in stable housings after excretion of veterinary medicinal products as parent compounds or metabolites and after the application of biocides in animal housings. Further entry routes such as solid dung application and direct dung pat deposition by production animals on pasture are not considered by this technical protocol. Thus, this technical protocol focused on the sampling of excrements from cattles and pigs kept in stables and fed under standard nutrition conditions. This approach additionally ensures that excrement samples are operationally free of any contamination by veterinary medicinal products and biocides. After the matrix characterization, reference-manure samples are prepared from the excrement samples by adding tap water to adjust defined dry substance contents typical for bovine or pig manures. This technical protocol comprehends a tiered experimental design in two parts: (a) Sampling of excrements and preparation of reference bovine and pig manures; (b) Testing of anaerobic transformation of chemicals in reference manures.

  1. In Vivo Cosmetic Product Efficacy Testing by Analyzing Epidermal Proteins Extracted from Tape Strips

    Directory of Open Access Journals (Sweden)

    Marie Westman

    2014-02-01

    Full Text Available The objective of this in vivo pilot study was to investigate whether differential biomarker analysis from skin tape strips could be used, not only to evaluate the difference between treated and untreated skin, but also to evaluate the effect of different product treatments. Ten volunteers were included in the study, applying two different basic formulations on their forearms. After four weeks of product application, and also after one week of treatment remission, tape strips were collected from the different treatment sites, as well as from untreated skin. The biomarkers investigated were selected to cover different aspects of epidermal differentiation and in connection with moisturization and barrier function. Levels of Involucrin were increased in both treatments, compared to untreated skin, whereas the levels of Keratin-6 were decreased for both treatments. In addition, a pattern for increased levels of Hornerin and Claudin-1 was also detected. There were no significant differences between the two treatments, only for treatment compared to untreated, but there were tendencies for different effect on some of the biomarkers investigated, differences that may reach significance with increased sample size. The major differences between the two treatments in this study were seen after one week of product remission, although due to too small sample size these differences were not significant.

  2. Analysis and results of a hydrogen-moderated isotope production assembly in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Wootan, D.W.; Rawlins, J.A.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1989-01-01

    This paper reports on a cobalt test assembly containing yttrium hydride pins for neutron moderation irradiated in the Fast Flux Test Facility (FFTF) during cycle 9A for 137.7 equivalent full-power days at a power level of 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal used to produce 60 Co and a set of four pins with europium oxide to produce 153 Gd, a radioisotope used in detection of the bone disease osteoporosis. Postirradiation examination of the cobalt pins determined the 60 Co production to be predictable to an accuracy of ∼ 5%. The measured 60 Co spatially distributed concentrations were within 20% of the calculated concentrations. The assembly average 60 Co measured activity was 4% less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes 152 Eu and 154 Eu to an absolute accuracy of ≅ 10%. The measured europium radioisotope and 153 Gd concentrations were within 20% of calculated values. The hydride assembly performed well and is an excellent vehicle for many FFTF isotope production applications. The results also demonstrate the accuracy of the calculational methods developed by the Westinghouse Hanford Company for predicting isotope production rates in this type of assembly

  3. Potential role of the Fast Flux Test Facility and the advanced test reactor in the U.S. tritium production system

    Energy Technology Data Exchange (ETDEWEB)

    Dautel, W.A.

    1996-10-01

    The Deparunent of Energy is currently engaged in a dual-track strategy to develop an accelerator and a conunercial light water reactor (CLWR) as potential sources of tritium supply. New analysis of the production capabilities of the Fast Flux Test Facility (FFTF) at the Hanford Site argues for considering its inclusion in the tritium supply,system. The use of the FFTF (alone or together with the Advanced Test Reactor [ATR] at the Idaho National Engineering Laboratory) as an integral part of,a tritium production system would help (1) ensure supply by 2005, (2) provide additional time to resolve institutional and technical issues associated with the- dual-track strategy, and (3) reduce discounted total life-cycle`costs and near-tenn annual expenditures for accelerator-based systems. The FFRF would also provide a way to get an early start.on dispositioning surplus weapons-usable plutonium as well as provide a source of medical isotopes. Challenges Associated With the Dual-Track Strategy The Departinent`s purchase of either a commercial reactor or reactor irradiation services faces challenging institutional issues associated with converting civilian reactors to defense uses. In addition, while the technical capabilities of the individual components of the accelerator have been proven, the entire system needs to be demonstrated and scaled upward to ensure that the components work toge ther 1548 as a complete production system. These challenges create uncertainty over the ability of the du2a-track strategy to provide an assured tritium supply source by 2005. Because the earliest the accelerator could come on line is 2007, it would have to operate at maximum capacity for the first few years to regenerate the reserves lost through radioactive decay aftei 2005.

  4. Potential role of the Fast Flux Test Facility and the advanced test reactor in the U.S. tritium production system

    International Nuclear Information System (INIS)

    Dautel, W.A.

    1996-01-01

    The Department of Energy is currently engaged in a dual-track strategy to develop an accelerator and a commercial light water reactor (CLWR) as potential sources of tritium supply. New analysis of the production capabilities of the Fast Flux Test Facility (FFTF) at the Hanford Site argues for considering its inclusion in the tritium supply,system. The use of the FFTF (alone or together with the Advanced Test Reactor [ATR] at the Idaho National Engineering Laboratory) as an integral part of,a tritium production system would help (1) ensure supply by 2005, (2) provide additional time to resolve institutional and technical issues associated with the- dual-track strategy, and (3) reduce discounted total life-cycle'costs and near-tenn annual expenditures for accelerator-based systems. The FFRF would also provide a way to get an early start.on dispositioning surplus weapons-usable plutonium as well as provide a source of medical isotopes. Challenges Associated With the Dual-Track Strategy The Department's purchase of either a commercial reactor or reactor irradiation services faces challenging institutional issues associated with converting civilian reactors to defense uses. In addition, while the technical capabilities of the individual components of the accelerator have been proven, the entire system needs to be demonstrated and scaled upward to ensure that the components work together 1548 as a complete production system. These challenges create uncertainty over the ability of the du2a-track strategy to provide an assured tritium supply source by 2005. Because the earliest the accelerator could come on line is 2007, it would have to operate at maximum capacity for the first few years to regenerate the reserves lost through radioactive decay after 2005

  5. Using Association Rules to Study the Co-evolution of Production & Test Code

    NARCIS (Netherlands)

    Lubsen, Z.; Zaidman, A.; Pinzger, M.

    2009-01-01

    Paper accepted for publication in the proceedings of the 6th International Working Conference on Mining Software Repositories (MSR 2009). Unit tests are generally acknowledged as an important aid to produce high quality code, as they provide quick feedback to developers on the correctness of their

  6. Studying Co-evolution of Production and Test Code Using Association Rule Mining

    NARCIS (Netherlands)

    Lubsen, Z.; Zaidman, A.; Pinzger, M.

    2009-01-01

    Long version of the short paper accepted for publication in the proceedings of the 6th International Working Conference on Mining Software Repositories (MSR 2009). Unit tests are generally acknowledged as an important aid to produce high quality code, as they provide quick feedback to developers on

  7. Mining Software Repositories to Study Co-Evolution of Production & Test Code

    NARCIS (Netherlands)

    Zaidman, A.E.; Van Rompaey, B.; Demeyer, S.; Van Deursen, A.

    2008-01-01

    Preprint of paper published in: ICST 2008 - Proceedings of the International Conference on Software Testing, Verification, and Validation, 2008; doi:10.1109/ICST.2008.47 Engineering software systems is a multidisciplinary activity, whereby a number of artifacts must be created — and maintained —

  8. Production and testing of an s-band resonator with a Nb3Sn surface

    International Nuclear Information System (INIS)

    Peiniger, M.

    1983-01-01

    This report describes the preparation of a niobium s-band resonator with Nb3Sn surface using a special vapor phase deposition method. High-frequency superconductivity tests were performed on this resonator. Measurements of transition temperature, penetration depth, energy gap, and temperature dependence of surface conductivity of Nb3Sn, and resonator behaviour at high electrical field strengths are reported. (GSCH)

  9. 75 FR 37593 - Energy Conservation Program for Consumer Products: Test Procedures for Clothes Dryers and Room...

    Science.gov (United States)

    2010-06-29

    ... docket number EERE-2008-BT-TP-0010 and/or RIN 1904-AC02 in the subject line of the message. 3. Mail: Ms... DOE clothes washer test procedure), which is assumed to proportionally impact dryer load sizes. DOE... noted that IEC Standard 62087 specifies methods of measuring the power consumption of TV receivers...

  10. 46 CFR 159.007-5 - Production inspections and tests: Application for acceptance.

    Science.gov (United States)

    2010-10-01

    ... acceptance. 159.007-5 Section 159.007-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS...) Is accepted by the Commandant for approval inspections and tests of the equipment or material under...

  11. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Science.gov (United States)

    2010-10-01

    ...'s procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND... meets the inspection and test procedures of the laboratory; and (3) Are accepted by the Commandant under...

  12. Simulating wall and corner fire tests on wood products with the OSU room fire model

    Science.gov (United States)

    H. C. Tran

    1994-01-01

    This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data...

  13. 75 FR 31223 - Energy Conservation Program for Consumer Products: Test Procedure for Residential Central Air...

    Science.gov (United States)

    2010-06-02

    ... Operating Tolerance Specified for the External Resistance to Airflow and the Nozzle Pressure Drop 6. Modify... Changes To Cover Triple-Capacity, Northern Heat Pumps 13. Specify Requirements for the Low-Voltage... Resistance to Airflow and the Nozzle Pressure Drop 6. Modify Third-Party Testing Requirements when Charging...

  14. A flag-up algorithm and test for nonstationary customer-specific product graphs

    DEFF Research Database (Denmark)

    Fenger, Morten H. J.; Scholderer, Joachim

    period. The results show that the test is clearly able to identify customers with evolving behavior, and that it can easily be deployed as part of a CRM system. It enables companies with loyalty programs to focus on nonstationary customers, i.e. customers who may represent opportunities for cross...

  15. 76 FR 62961 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2011-10-11

    .... Protection of Children J. Indian Tribal Governments K. Energy Effects L. International Trade Impacts M... appropriate Coast Guard oversight ultimately promotes safety, flexibility, and autonomy by permitting experts... will accept test reports from Coast Guard-accepted independent laboratories in support of approvals for...

  16. 75 FR 31688 - Third Party Testing for Certain Children's Products; Infant Bath Seats: Requirements for...

    Science.gov (United States)

    2010-06-04

    ... requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing....html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the... tested by a third party conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA...

  17. 75 FR 42311 - Third Party Testing for Certain Children's Products; Vinyl Plastic Film: Requirements for...

    Science.gov (United States)

    2010-07-21

    ... ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing memorandum....org/membersbycategory.html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General... conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA member at the time of the test...

  18. 75 FR 51016 - Third Party Testing for Certain Children's Products; Clothing Textiles: Requirements for...

    Science.gov (United States)

    2010-08-18

    ... (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements for... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and...

  19. 76 FR 18645 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Science.gov (United States)

    2011-04-05

    ... to the International Standards Organization (ISO)/International Electrotechnical Commission (IEC) Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and Calibration... paint ban and 16 CFR part 1303, it must be accredited to ISO/IEC 17025- 2005 by an accreditation body...

  20. PYROLYTIC PRODUCTS FROM TRYPTOPHAN AND GLUTAMIC-ACID ARE POSITIVE IN THE MAMMALIAN SPOT-TEST

    DEFF Research Database (Denmark)

    Jensen, Niels Juul

    1983-01-01

    Pyrolysates of tryptophan (Trp-P-2) and glutamic acid (Glu-P-1) are known mutagens in in vitro short term mutagenicity tests, and have also shown carcinogenic effects in long term animal studies. The present study demonstrates that they also produce mutations in somatic cells. This result...

  1. Speech production in people who stutter: Testing the motor plan assembly hypothesis

    NARCIS (Netherlands)

    Lieshout, P.H.H.M. van; Hulstijn, W.; Peters, H.F.M.

    1996-01-01

    The main purpose of the present study was to test the hypothesis that persons who stutter, when compared to persons who do not stutter, are less able to assemble abstract motor plans for short verbal responses. Subjects were adult males who stutter and age- and sex-matched control speakers, who were

  2. Compatibility tests of materials for a prototype ceramic melter for defense glass-waste products

    International Nuclear Information System (INIS)

    Wicks, G.G.

    1979-01-01

    Objective is to evaluate the corrosion/erosion resistance of melter materials. Materials tested were Monofrox K3 and E, Serv, Inconel 690, Pt, and SnO. Results show that Inconel 690 is the leading electrode material and Monofrox K3 the leading refractory candidate. Melter lifetime is estimated to be 2 to 5 years for defense waste

  3. Production of a manual on testing methods for the use of bamboo in engineering applications

    NARCIS (Netherlands)

    Janssen, J.J.A.; Kumar, Arun; Ramanuja Rao, I.V.; Sastry, Cherla

    1998-01-01

    Tests on different properties of bamboo are being conducted in many laboratories in bamboo-growing countries. In the absence of standards that prescribe definite methods, the laboratory staff often has to improvise and innovate to find clever methods or tools. In many cases, such useful information

  4. 78 FR 63410 - Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment...

    Science.gov (United States)

    2013-10-24

    ... test procedures for direct heating equipment and pool heaters established under the Energy Policy and... U.S.C. 6293(e)(2)) The current energy conservation standards for direct heating equipment and pool... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2013-BT-TP-0004] RIN 1904-AC94 Energy...

  5. Does functional trait diversity predict aboveground biomass and productivity of tropical forests? Testing three alternative hypotheses

    NARCIS (Netherlands)

    Finegan, B.; Pena Claros, M.; Silva de Oliveira, A.; Ascarrunz, N.; Bret-Harte, M.S.; Carreño Rocabado, I.G.; Casanoves, F.; Diaz, S.; Eguiguren Velepucha, P.; Fernandez, F.; Licona, J.C.; Lorenzo, L.; Salgado Negret, B.; Vaz, M.; Poorter, L.

    2014-01-01

    1. Tropical forests are globally important, but it is not clear whether biodiversity enhances carbon storage and sequestration in them. We tested this relationship focusing on components of functional trait biodiversity as predictors. 2. Data are presented for three rain forests in Bolivia, Brazil

  6. Does functional trait diversity predict aboveground biomass and productivity of tropical forests? Testing three alternative hypotheses

    NARCIS (Netherlands)

    Finegan, B.; Peña Claros, M.; Oliviera, de A.; Alarcón, A.; Ascarrunz, N.; Bret-Harte, M.S.; Carreño-Rocabado, G.; Casanoves, F.; Díaz, S.; Eguiguren Velepucha, P.; Fernandez, F.; Licona, J.C.; Lorenzo, L.; Salgado Negret, B.; Vaz, M.; Poorter, L.

    2015-01-01

    Tropical forests are globally important, but it is not clear whether biodiversity enhances carbon storage and sequestration in them. We tested this relationship focusing on components of functional trait biodiversity as predictors. Data are presented for three rain forests in Bolivia, Brazil and

  7. 78 FR 675 - Energy Conservation Program for Consumer Products: Test Procedure for Residential Furnaces and...

    Science.gov (United States)

    2013-01-04

    ... WordPerfect, Microsoft Word, PDF, or ASCII file format, and avoid the use of special characters or any... furnaces and boilers is found at 10 CFR 430.23(n) and 10 CFR part 430, subpart B, appendix N, Uniform Test... such as fuel calorific value, weight of condensate, water flow and temperature, voltage, and flue gas...

  8. Influence of raw milk quality on processed dairy products: How do raw milk quality test results relate to product quality and yield?

    Science.gov (United States)

    Murphy, Steven C; Martin, Nicole H; Barbano, David M; Wiedmann, Martin

    2016-12-01

    This article provides an overview of the influence of raw milk quality on the quality of processed dairy products and offers a perspective on the merits of investing in quality. Dairy farmers are frequently offered monetary premium incentives to provide high-quality milk to processors. These incentives are most often based on raw milk somatic cell and bacteria count levels well below the regulatory public health-based limits. Justification for these incentive payments can be based on improved processed product quality and manufacturing efficiencies that provide the processor with a return on their investment for high-quality raw milk. In some cases, this return on investment is difficult to measure. Raw milks with high levels of somatic cells and bacteria are associated with increased enzyme activity that can result in product defects. Use of raw milk with somatic cell counts >100,000cells/mL has been shown to reduce cheese yields, and higher levels, generally >400,000 cells/mL, have been associated with textural and flavor defects in cheese and other products. Although most research indicates that fairly high total bacteria counts (>1,000,000 cfu/mL) in raw milk are needed to cause defects in most processed dairy products, receiving high-quality milk from the farm allows some flexibility for handling raw milk, which can increase efficiencies and reduce the risk of raw milk reaching bacterial levels of concern. Monitoring total bacterial numbers in regard to raw milk quality is imperative, but determining levels of specific types of bacteria present has gained increasing importance. For example, spores of certain spore-forming bacteria present in raw milk at very low levels (e.g., products to levels that result in defects. With the exception of meeting product specifications often required for milk powders, testing for specific spore-forming groups is currently not used in quality incentive programs in the United States but is used in other countries (e.g., the

  9. Standard test method for determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX Aluminum alloy products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a uniform procedure for characterizing the resistance to stress-corrosion cracking (SCC) of high-strength aluminum alloy wrought products for the guidance of those who perform stress-corrosion tests, for those who prepare stress-corrosion specifications, and for materials engineers. 1.2 This test method covers method of sampling, type of specimen, specimen preparation, test environment, and method of exposure for determining the susceptibility to SCC of 2XXX (with 1.8 to 7.0 % copper) and 7XXX (with 0.4 to 2.8 % copper) aluminum alloy products, particularly when stressed in the short-transverse direction relative to the grain structure. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound units in parentheses are provided for information. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and de...

  10. Ecological toxicity estimation of solid waste products of Tekely Ore Mining and Processing Enterprise of OJSC 'Kaztsink' using biological testing methods

    International Nuclear Information System (INIS)

    Vetrinskaya, N.I.; Goldobina, E.A.; Kosmukhambetov, A.R.; Kulikova, O.V.; Ismailova, Zh.B.; Gurikova, N.D.; Kozlova, N.V.

    2001-01-01

    Results are examined of solid waste products estimation using methods of biological testing at testing-objects of different phylogenetic development levels (simple aqua animals, algae, supreme water plants). Correlation is found between lead and zinc content in the extract of leaching out and exact reaction of all under-test objects. Conclusion is made that performing of the complex express economical analysis is necessary using methods of biological testing of industrial waste products monitoring and other man-made pollutants. (author)

  11. Model test on the relationship feed energy and protein ratio to the production and quality of milk protein

    Science.gov (United States)

    Hartanto, R.; Jantra, M. A. C.; Santosa, S. A. B.; Purnomoadi, A.

    2018-01-01

    The purpose of this research was to find an appropriate relationship model between the feed energy and protein ratio with the amount of production and quality of milk proteins. This research was conducted at Getasan Sub-district, Semarang Regency, Central Java Province, Indonesia using 40 samples (Holstein Friesian cattle, lactation period II-III and lactation month 3-4). Data were analyzed using linear and quadratic regressions, to predict the production and quality of milk protein from feed energy and protein ratio that describe the diet. The significance of model was tested using analysis of variance. Coefficient of determination (R2), residual variance (RV) and root mean square prediction error (RMSPE) were reported for the developed equations as an indicator of the goodness of model fit. The results showed no relationship in milk protein (kg), milk casein (%), milk casein (kg) and milk urea N (mg/dl) as function of CP/TDN. The significant relationship was observed in milk production (L or kg) and milk protein (%) as function of CP/TDN, both in linear and quadratic models. In addition, a quadratic change in milk production (L) (P = 0.003), milk production (kg) (P = 0.003) and milk protein concentration (%) (P = 0.026) were observed with increase of CP/TDN. It can be concluded that quadratic equation was the good fitting model for this research, because quadratic equation has larger R2, smaller RV and smaller RMSPE than those of linear equation.

  12. Fuel behaviour and fission product release under realistic hydrogen conditions comparisons between HEVA 06 test results and Vulcain computations

    International Nuclear Information System (INIS)

    Dumas, J.M.; Lhiaubet, G.

    1989-07-01

    The HEVA 06 test was designed to simulate the conditions existing at the time when fission products are released from irradiated fuel under hydrogen conditions occurring in a PWR core at low pressure. The test conditions were defined from results provided by the core degradation module of the ESCADRE system (1): VULCAIN. This computer code has been recently used to analyse the early core degradation of a 900 MWe PWR in the AF accident sequence (as defined in WASH - 1400, USNRC - 1975). In this scenario, the core would begin to uncover about one day after scram with the system pressure at about 0.4 MPa. The fission product release starts 70 minutes after core dewatering. The F.P. are transferred to the core outlet in an increasingly hydrogen-rich steam atmosphere. The carrier gas is nearly pure hydrogen in the time period 100 - 130 minutes after core uncovering. A large release of F.P. is predicted in the upper part of the core when the steam starvation occurs. At that time, two thirds of the cladding have been oxidised on an average. Before each HEVA test a fuel sample with a burn-up of 36 GWd/tU is reirradiated in order to observe the release of short-lived fission products. A pre-oxidation was primarely conducted in the HEVA 06 test at a temperature of 1300 0 C and controlled to reach a 2/3 cladding oxidation state. Then the steam was progressively replaced by hydrogen and a heat-up rate of 1.5 0 C/s was induced to reach a temperature of 2100 0 C. The fuel was maintained at this temperature for half an hour in hydrogen. The volatile F.P. release kinetics were observed by on-line gamma spectrometry. Pre test calculations of F.P. release kinetics performed with the EMIS module based on the CORSOR models (3) are compared with the test results. Measured releases of cesium and iodine are really lower than those predicted. Axial and radial F.P. distributions in the fuel pellets are available from gamma tomography measurements performed after the test. Tellurium seems

  13. Automatic testing devices for diesel engines for the quality control in engine production

    Energy Technology Data Exchange (ETDEWEB)

    Homann, R; Homilius, K

    1979-01-01

    A device which generates the torque for the brakes is the most important functional group in engine test stands. Hydraulic dynamometric brakes are serially produced for power ranges from 210 up to 70000 kw and maximum revolutions up to 10000 rpm. Eddy current brakes can be supplied for the power range of 40 to 3600 kW. Compared to the hydraulic dynamometric brake they have a larger rev-range for control while both have the same torque. Electric machines used as dynamometric brakes make it possible to recuperate electric energy. The properties of the individual braking devices are compared. Torque and number of revolutions are calculated digitally. Test methods are automatised as far as possible. There are four control methods: time plan, perforated strip, magnetic tape or computer.

  14. Feedstock to Tailpipe Initiative: Kansas Biofuels Production, Testing and Certification Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Stagg-Williams, Susan M. [Univ. of Kansas, Lawrence, KS (United States). Dept. of Chemical and Petroleum Engineering; Depcik, Chris [Univ. of Kansas, Lawrence, KS (United States). Dept. of Chemical and Petroleum Engineering; Sturm, Belinda [Univ. of Kansas, Lawrence, KS (United States). Dept. of Chemical and Petroleum Engineering

    2013-12-31

    The primary task of this grant was to establish an ASTM testing facility for biodiesel and ethanol and to use this facility to develop methods to predict fuel characteristics based on feedstock composition and feedstock cultivation. In addition to characterizing fuel properties, this grant allowed for the purchase and installation of a Fourier Transform Infrared Spectroscopy (FTIR) emissions analyzer that will provide an analysis of the emissions leaving the engine in order to meet EPA regulations. This FTIR system is combined with an Alternating Current (AC) dynamometer that allows the engine to follow Environmental Protection Agency (EPA) Federal Test Procedure (FTP) cycles. A secondary task was to investigate cultivating algae utilizing wastewater and top-down ecological control and subsequent harvesting using coagulation and dissolved air flotation. Lipid extraction utilizing environmentally-friendly and cost-effective solvents, with and without cell-disruption pretreatment was also explored. Significant work on the hydrothermal liquefaction of wastewater cultivated algae was conducted.

  15. Irradiation tests of 99Mo isotope production targets employing uranium metal foils

    International Nuclear Information System (INIS)

    Hofman, G.L.; Wiencek, T.C.; Wood, E.L.; Snelgrove, J.L.; Suripto, A.; Nasution, H.; Lufti-Amin, D.; Gogo, A.

    1996-01-01

    Most of the world's supply of 99 mTc for medical purposes is currently produced from the decay of 99 Mo derived from the fissioning of high-enriched uranium (HEU). Substitution of low-enriched uranium (LEU) metal foils for the HEU UO 2 used in current target designs will allow equivalent 99 Mo yields with little change in target geometries. Substitution of uranium metal for uranium alloy and aluminide in other target designs will also allow the conversion of HEU to LEU. Several uranium-metal-foil targets have been fabricated at ANL and irradiated to prototypic burnup in the Indonesian RSG-GAS reactor. Postirradiation examination of the initial test indicated that design modifications were required to allow the irradiated foil to be removed for chemical processing. The latest test has shown good irradiation behavior, satisfactory dismantling and foil removal when the U-foil is separated from its containment by metallic, fission-recoil absorbing barriers. (author)

  16. Irradiation tests of 99Mo isotope production targets employing uranium metal foils

    International Nuclear Information System (INIS)

    Hofman, G.L.; Wiencek, T.C.; Wood, E.L.; Snelgrove, J.L.; Suripto, A.; Nasution, H.; Lufti-Amin, D.; Gogo, A.

    1996-01-01

    Most of the world's supply of 99m Tc for medical purposes is currently produced form the decay of 99 Mo derived from the fissioning of high-enriched uranium (HEU). Substitution of low-enriched uranium (LEU) metal foils for the HEU UO 2 used in current target designs will allow equivalent 99 Mo yields with little change in target geometries. Substitution of uranium metal for uranium alloy and aluminide in other target designs will also allow the conversion of HEU to LEU. Several uranium-metal-foil targets have been fabricated at ANL and irradiated to prototypic burnup in the Indonesian RSG-GAS reactor. Postirradiation examination of the initial test indicated that design modifications were required to allow the irradiated foil to be removed for chemical processing. The latest test has shown good irradiation behavior, satisfactory dismantling and foil removal when the U-foil is separated from its containment by metallic, fission-recoil absorbing barriers

  17. Choosing offspring: prenatal genetic testing for thalassaemia and the production of a 'saviour sibling' in China.

    Science.gov (United States)

    Sui, Suli; Sleeboom-Faulkner, Margaret

    2010-02-01

    This paper focuses on the pre-natal genetic testing and reproductive decision-making around thalassaemia in China. Findings are based on fieldwork conducted in hospitals and research institutions, interviews with families with thalassaemia-affected children, interviews with geneticists and genetic researchers and a literature review conducted between September and November 2007. The paper aims to provide insight into the ways in which those who carry thalassaemia decide to have a test for the condition and the choices available to prospective parents. The paper also analyses factors affecting reproductive choices and the decision to produce a 'saviour sibling', including financial implications, state family planning policy, images and information conveyed through the media and propaganda, advice and counselling from doctors, psychological pressure from the community and social discrimination. The paper concludes with a discussion on the issues involved in the creation of saviour siblings, some of which are particular to China.

  18. Testing various types of agricultural wastes for the production of generator gas

    Energy Technology Data Exchange (ETDEWEB)

    Kjellstroem, B

    1982-05-08

    The aim of the project was to get an improved basis for the assessment of aretes which was required for use in a Swedish gas generator. It was found that waste which possessed high contents of ashes with a low melting point were unsuitable as a fuel. Four types of waste were tested. The shells of coconuts were applicable as fuel. The design of the generator had to be modified in order to use pellets of straw or compressed sugar-canes.

  19. A strategy for in vitro safety testing of nanotitania-modified textile products

    International Nuclear Information System (INIS)

    Roszak, Joanna; Stępnik, Maciej; Nocuń, Marek; Ferlińska, Magdalena; Smok-Pieniążek, Anna; Grobelny, Jarosław; Tomaszewska, Emilia; Wąsowicz, Wojciech; Cieślak, Małgorzata

    2013-01-01

    Highlights: • Commercially available TiO 2 /Ag nanomaterials (NMs) showed higher cytotoxic effect than TiO 2 NMs. • Both titania NMs in pristine form induced a weak genotoxic effect in in vitro studies. • Cytotoxic effect of textile materials modified with TiO 2 /Ag NMs depended on the mode of the fiber manufacturing. • The strategy of in vitro testing of textile materials modified with NMs was proposed. -- Abstract: Titanium dioxide nanomaterials are extensively used in many applications, also for modification of textile materials. Toxicological assessment of such textile materials is currently seldom performed, mainly because of lack of appropriate guidelines. The aim of the study was to assess cytotoxic and genotoxic potential of commercially available TiO 2 and TiO 2 /Ag NMs in pristine form as well as polypropylene fibers modified with the NMs. Both titania NMs showed a cytotoxic effect on BALB/3T3 clone A31 and V79 fibroblasts after 72-h exposure. Both NMs induced a weak genotoxic effect in comet assay, with TiO 2 /Ag being more active. In vitro micronucleus test on human lymphocytes revealed a weak mutagenic effect of both materials after 24 h of exposure. In contrast, no significant increase in micronuclei frequency was observed in the in vitro micronucleus test on V79 fibroblasts. The 24-h extracts prepared from polypropylene fibers modified with TiO 2 /Ag induced a cytotoxic effect on BALB/3T3 cells which strongly depended on the mode of the fibers manufacturing. The study presents a comprehensive approach to toxicity assessment of textile fibers modified with NMs. Proposed approach may form a good “starting point” for improved future testing strategies

  20. Production and Test of 352 MHZ Niobum-Sputtered Reduced-$\\beta$ Cavities

    CERN Document Server

    Benvenuti, Cristoforo; Calatroni, Sergio; Chiaveri, Enrico; Tückmantel, Joachim

    1997-01-01

    Three types of 352 MHz single-cell cavities foreseen for different particle speeds (v/c=0.8, 0.625 and 0.48) have been designed and built with the niobium sputtered on copper technique. We report on the results of the cold tests at 4.5 and 2.5 K and the actual status of the data analysis.