WorldWideScience

Sample records for production method test

  1. 46 CFR 57.06-3 - Method of performing production testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Method of performing production testing. 57.06-3 Section 57.06-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-3 Method of performing production testing. (a) Except as...

  2. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  3. Dissolution testing of intermediary products in uranium dioxide production by the sol-gel method

    International Nuclear Information System (INIS)

    Melichar, F.; Landspersky, H.; Urbanek, V.

    1979-01-01

    A method was developed of dissolving polyuranates and uranium dioxides in sulphuric acid and in carbonate solutions for testing intermediate products in the sol-gel process preparation of uranium dioxide. A detailed granulometric analysis of spherical particle dispersion was included as part of the tests. Two different production methods were used for the two types of studied materials. The test results show that the test method is suitable for determining temperature sensitivity of the materials to dissolution reaction. The geometrical distribution of impurities in the spherical particles can be determined from the dissolution kinetics. The method allows the determination of the effect of carbon from impurities on the process of uranium dioxide leaching and is thus applicable for testing materials prepared by the sol-gel method. (Z.M.)

  4. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    Science.gov (United States)

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  5. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  6. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  7. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  8. Improving Papanicolaou test quality and reducing medical errors by using Toyota production system methods.

    Science.gov (United States)

    Raab, Stephen S; Andrew-Jaja, Carey; Condel, Jennifer L; Dabbs, David J

    2006-01-01

    The objective of the study was to determine whether the Toyota production system process improves Papanicolaou test quality and patient safety. An 8-month nonconcurrent cohort study that included 464 case and 639 control women who had a Papanicolaou test was performed. Office workflow was redesigned using Toyota production system methods by introducing a 1-by-1 continuous flow process. We measured the frequency of Papanicolaou tests without a transformation zone component, follow-up and Bethesda System diagnostic frequency of atypical squamous cells of undetermined significance, and diagnostic error frequency. After the intervention, the percentage of Papanicolaou tests lacking a transformation zone component decreased from 9.9% to 4.7% (P = .001). The percentage of Papanicolaou tests with a diagnosis of atypical squamous cells of undetermined significance decreased from 7.8% to 3.9% (P = .007). The frequency of error per correlating cytologic-histologic specimen pair decreased from 9.52% to 7.84%. The introduction of the Toyota production system process resulted in improved Papanicolaou test quality.

  9. New X-ray testing methods of aerosol products for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bozydar Knyziak, Adrian, E-mail: a.knyziak@gum.gov.pl; Rzodkiewicz, Witold, E-mail: w.rzodkiewicz@gum.gov.pl; Kaczorowska, Ewa, E-mail: e.kaczorowska@gum.gov.pl; Derlacinski, Michal, E-mail: m.derlacinski@gum.gov.pl

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  10. Comprehensive validation scheme for in situ fiber optics dissolution method for pharmaceutical drug product testing.

    Science.gov (United States)

    Mirza, Tahseen; Liu, Qian Julie; Vivilecchia, Richard; Joshi, Yatindra

    2009-03-01

    There has been a growing interest during the past decade in the use of fiber optics dissolution testing. Use of this novel technology is mainly confined to research and development laboratories. It has not yet emerged as a tool for end product release testing despite its ability to generate in situ results and efficiency improvement. One potential reason may be the lack of clear validation guidelines that can be applied for the assessment of suitability of fiber optics. This article describes a comprehensive validation scheme and development of a reliable, robust, reproducible and cost-effective dissolution test using fiber optics technology. The test was successfully applied for characterizing the dissolution behavior of a 40-mg immediate-release tablet dosage form that is under development at Novartis Pharmaceuticals, East Hanover, New Jersey. The method was validated for the following parameters: linearity, precision, accuracy, specificity, and robustness. In particular, robustness was evaluated in terms of probe sampling depth and probe orientation. The in situ fiber optic method was found to be comparable to the existing manual sampling dissolution method. Finally, the fiber optic dissolution test was successfully performed by different operators on different days, to further enhance the validity of the method. The results demonstrate that the fiber optics technology can be successfully validated for end product dissolution/release testing. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  11. Non-destructive testing method for determining the solvent diffusion coefficient in the porous materials products

    Science.gov (United States)

    Belyaev, V. P.; Mishchenko, S. V.; Belyaev, P. S.

    2018-01-01

    Ensuring non-destructive testing of products in industry is an urgent task. Most of the modern methods for determining the diffusion coefficient in porous materials have been developed for bodies of a given configuration and size. This leads to the need for finished products destruction to make experimental samples from them. The purpose of this study is the development of a dynamic method that allows operatively determine the diffusion coefficient in finished products from porous materials without destroying them. The method is designed to investigate the solvents diffusion coefficient in building constructions from materials having a porous structure: brick, concrete and aerated concrete, gypsum, cement, gypsum or silicate solutions, gas silicate blocks, heat insulators, etc. A mathematical model of the method is constructed. The influence of the design and measuring device operating parameters on the method accuracy is studied. The application results of the developed method for structural porous products are presented.

  12. Generating and testing methods for consumer-oriented product development; Genererende en toetsingsmethoden voor consumentgerichte productontwikkeling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process. [Dutch] Om een goed inzicht te krijgen in verschillende ontwerpmethoden die productontwikkelaars kunnen gebruiken om bruikbare domoticaproducten te kunnen ontwikkelen en toetsen, is een inventarisatie uitgevoerd naar de methoden die in Nederland worden gebruikt. De inventarisatie richt zich op twee categorieen methoden: (1) methoden om de gebruiker casu quo het probleem beter te leren kennen en nieuwe oplossingen te genereren, zogenaamde genererende methoden, en (2) methoden om oplossingen te evatueren (in verschillende fasen van het ontwerpproces), zogenaamde toetsingsmethoden. De eerste categorie methoden richt zich op het ontwerpproces: hoe kan de ontwerper tijdens het ontwerpproces de bruikbaarheid van (domotica)producten zoveel mogelijk realiseren? De tweede categorie methoden is erop gericht om een ontwerp (in wat voor vorm dan ook: tekening, prototype, functionele computeranimatie, enzovoort) te toetsen bij gebruikers. Het zijn methoden om een ontwerp, op verschillende momenten

  13. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  14. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  15. Tobacco and Nicotine Product Testing

    Science.gov (United States)

    Biener, Lois; Leischow, Scott J.; Zeller, Mitch R.

    2012-01-01

    Introduction: Tobacco product testing is a critical component of the Family Smoking Prevention and Tobacco Control Act (FSPTCA), which grants the Food and Drug Administration the authority to regulate tobacco products. The availability of methods and measures that can provide accurate data on the relative health risks across types of tobacco products, brands, and subbrands of tobacco products on the validity of any health claims associated with a product, and on how consumers perceive information on products toxicity or risks is crucial for making decisions on the product's potential impact on public health. These tools are also necessary for making assessments of the impact of new indications for medicinal products (other than cessation) but more importantly of tobacco products that may in the future be marketed as cessation tools. Objective: To identify research opportunities to develop empirically based and comprehensive methods and measures for testing tobacco and other nicotine-containing products so that the best science is available when decisions are made about products or policies. Methods: Literature was reviewed to address sections of the FSPTCA relevant to tobacco product evaluation; research questions were generated and then reviewed by a committee of research experts. Results: A research agenda was developed for tobacco product evaluation in the general areas of toxicity and health risks, abuse liability, consumer perception, and population effects. Conclusion: A cohesive, systematic, and comprehensive assessment of tobacco products is important and will require building consensus and addressing some crucial research questions. PMID:21460383

  16. The Development of Testing Methods for Characterizing Emissions and Sources of Exposures from Polyurethane Products

    Science.gov (United States)

    The relationship between onsite manufacture of spray polyurethane foam insulation (SPFI) and potential exposures is not well understood. Currently, no comprehensive standard test methods exist for characterizing and quantifying product emissions. Exposures to diisocyanate compoun...

  17. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  18. 30 CFR 27.31 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 27.31 Section 27.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.31 Testing methods. A methane...

  19. Ecological toxicity estimation of solid waste products of Tekely Ore Mining and Processing Enterprise of OJSC 'Kaztsink' using biological testing methods

    International Nuclear Information System (INIS)

    Vetrinskaya, N.I.; Goldobina, E.A.; Kosmukhambetov, A.R.; Kulikova, O.V.; Ismailova, Zh.B.; Gurikova, N.D.; Kozlova, N.V.

    2001-01-01

    Results are examined of solid waste products estimation using methods of biological testing at testing-objects of different phylogenetic development levels (simple aqua animals, algae, supreme water plants). Correlation is found between lead and zinc content in the extract of leaching out and exact reaction of all under-test objects. Conclusion is made that performing of the complex express economical analysis is necessary using methods of biological testing of industrial waste products monitoring and other man-made pollutants. (author)

  20. Endurance test for IR rig for RI production assembly (test procedure)

    International Nuclear Information System (INIS)

    Chung, Heung June; Ryu, Jeong Soo

    2000-08-01

    This test procedure details the test loop, test method, and test procedure for pressure drop, vibration and endurance test of IR Rig for RI production. From the pressure drop test, the hydraulic design requirements of the capsule are verified. HANARO limit condition is checked and the compatibility with HANARO core is verified. From flow induced vibration test vibration frequency and displacement are investigated. The wear of IR Rig is investigated through endurance test, and these data are used to evaluate the expected wear at maximum resident time of the IR Rig for RI production

  1. 40 CFR 59.207 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...

  2. Standard test method for determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX Aluminum alloy products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a uniform procedure for characterizing the resistance to stress-corrosion cracking (SCC) of high-strength aluminum alloy wrought products for the guidance of those who perform stress-corrosion tests, for those who prepare stress-corrosion specifications, and for materials engineers. 1.2 This test method covers method of sampling, type of specimen, specimen preparation, test environment, and method of exposure for determining the susceptibility to SCC of 2XXX (with 1.8 to 7.0 % copper) and 7XXX (with 0.4 to 2.8 % copper) aluminum alloy products, particularly when stressed in the short-transverse direction relative to the grain structure. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound units in parentheses are provided for information. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and de...

  3. Major advances in testing of dairy products: milk component and dairy product attribute testing.

    Science.gov (United States)

    Barbano, D M; Lynch, J M

    2006-04-01

    Milk component analysis is relatively unusual in the field of quantitative analytical chemistry because an analytical test result determines the allocation of very large amounts of money between buyers and sellers of milk. Therefore, there is high incentive to develop and refine these methods to achieve a level of analytical performance rarely demanded of most methods or laboratory staff working in analytical chemistry. In the last 25 yr, well-defined statistical methods to characterize and validate analytical method performance combined with significant improvements in both the chemical and instrumental methods have allowed achievement of improved analytical performance for payment testing. A shift from marketing commodity dairy products to the development, manufacture, and marketing of value added dairy foods for specific market segments has created a need for instrumental and sensory approaches and quantitative data to support product development and marketing. Bringing together sensory data from quantitative descriptive analysis and analytical data from gas chromatography olfactometry for identification of odor-active compounds in complex natural dairy foods has enabled the sensory scientist and analytical chemist to work together to improve the consistency and quality of dairy food flavors.

  4. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  5. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  6. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... method in production on actual production parts or assemblies for a period of time sufficient to coat an... a laboratory or pilot production area, using parts and coatings representative of the process(es) where the alternative method is to be used. The laboratory test will use the same part configuration(s...

  7. Evaluation of Alternative Methods for Testing the Bioefficacy of Household Ambient Insecticide Products Against Aedes albopictus.

    Science.gov (United States)

    Cassini, Rudi; Scremin, Mara; Contiero, Barbara; Drago, Andrea; Vettorato, Christian; Marcer, Federica; di Regalbono, Antonio Frangipane

    2016-06-01

    Ambient insecticides are receiving increasing attention in many developed countries because of their value in reducing mosquito nuisance. As required by the European Union Biocidal Products Regulation 528/2012, these devices require appropriate testing of their efficacy, which is based on estimating the knockdown and mortality rates of free-flying (free) mosquitoes in a test room. However, evaluations using free mosquitoes present many complexities. The performances of 6 alternative methods with mosquitoes held in 2 different cage designs (steel wire and gauze/plastic) with and without an operating fan for air circulation were monitored in a test room through a closed-circuit television system and were compared with the currently recommended method using free mosquitoes. Results for caged mosquitoes without a fan showed a clearly delayed knockdown effect, whereas outcomes for caged mosquitoes with a fan recorded higher mortality at 24 h, compared to free mosquitoes. Among the 6 methods, cages made of gauze and plastic operating with fan wind speed at 2.5-2.8 m/sec was the only method without a significant difference in results for free mosquitoes, and therefore appears as the best alternative to assess knockdown by ambient insecticides accurately.

  8. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  9. Methodological issues in testing the marginal productivity theory

    NARCIS (Netherlands)

    P.T. Gottschalk (Peter); J. Tinbergen (Jan)

    1982-01-01

    textabstractPrevious tests of the marginal productivity theory have been criticized on several grounds reviewed by the authors. One important deficiency has been the small number of factor inputs entered in the production functions. In 1978 Gottschalk suggested a method to estimate production

  10. Central location test vs. home use test: Contrasting results depending on product type

    NARCIS (Netherlands)

    Boutrolle, I.; Delarue, J.; Arranz, D.; Rogeaux, M.; Köster, E.P.

    2007-01-01

    Marketing professionals and sensory scientists have several hedonic testing methods at their disposal to assess product acceptability. The central location test (CLT) which usually takes place in a standardised location under controlled conditions is more frequently used than the home use test

  11. An Intelligent Method of Product Scheme Design Based on Product Gene

    Directory of Open Access Journals (Sweden)

    Qing Song Ai

    2013-01-01

    Full Text Available Nowadays, in order to have some featured products, many customers tend to buy customized products instead of buying common ones in supermarket. The manufacturing enterprises, with the purpose of improving their competitiveness, are focusing on providing customized products with high quality and low cost as well. At present, how to produce customized products rapidly and cheaply has been the key challenge to manufacturing enterprises. In this paper, an intelligent modeling approach applied to supporting the modeling of customized products is proposed, which may improve the efficiency during the product design process. Specifically, the product gene (PG method, which is an analogy of biological evolution in engineering area, is employed to model products in a new way. Based on product gene, we focus on the intelligent modeling method to generate product schemes rapidly and automatically. The process of our research includes three steps: (1 develop a product gene model for customized products; (2 find the obtainment and storage method for product gene; and (3 propose a specific genetic algorithm used for calculating the solution of customized product and generating new product schemes. Finally, a case study is applied to test the usefulness of our study.

  12. Dissolution test for low-activity waste product acceptance

    International Nuclear Information System (INIS)

    Ebert, W. L.

    1998-01-01

    We have measured the mean and standard deviation of the solution concentrations of B, Na, and Si attained in replicate dissolution tests conducted at temperatures of 20, 40, and 70 C, for durations of 3 and 7 days, and at glass/water mass ratios of 1:10 and 1:1. These and other tests were conducted to evaluate the adequacy of the test methods specified in privatization contracts and to develop a data base that can be used to evaluate the reliability of reported results for tests performed on the waste products. Tests were conducted with a glass that we formulated to be similar to low-activity waste products that will be produced during the remediation of Hanford tank wastes. Statistical analyses indicated that, while the mean concentrations of B, Na, and Si were affected by the values of test parameters, the standard deviation of replicate tests was not. The precision of the tests was determined primarily by uncertainties in the analysis of the test solutions. Replicate measurements of other glass properties that must be reported for Hanford low-activity waste products were measured to evaluate the possible adoption of the glass used in these tests as a standard test material for the product acceptance process

  13. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  14. Teste de TBA aplicado a carnes e derivados: métodos tradicionais, modificados e alternativos TBA test applied to meats and their products: traditional, modified and alternative methods

    Directory of Open Access Journals (Sweden)

    Cibele Cristina Osawa

    2005-08-01

    Full Text Available The TBA test is essential to quality control of fat-containing food, being the test most applied to evaluate lipid peroxidation in fishery, meat and poultry products. It estimates malonaldehyde, a secondary oxidation product, by reacting with 2-thiobarbituric acid, forming a coloured complex, measured spectrophotometrically atlambda = 532 nm. Results are expressed as mg malonaldehyde per kg sample or frequently as "TBA value". There are four ways of quantifying it: by lipid extraction, direct heating, distillation or heat-acid extraction. This review intends to point out traditional, modified and alternative TBA test methods, besides enumerating advantages and drawbacks of each one.

  15. Chemical test for mammalian feces in grain products: collaborative study.

    Science.gov (United States)

    Gerber, H R

    1989-01-01

    A collaborative study was conducted to validate the use of the AOAC alkaline phosphatase method for mammalian feces in corn meal, 44.B01-44.B06, for 7 additional products: brown rice cream, oat bran, grits, semolina, pasta flour, farina, and barley plus (a mixture of barley, oat bran, and brown rice). The proposed method determines the presence of alkaline phosphatase, an enzyme contained in mammalian feces, by using phenolphthalein diphosphate as the enzyme substrate in a test agar medium. Fecal matter is separated from the grain products by specific gravity differences in 1% test agar. As the product is distributed on liquid test agar, fecal fragments float while the grain products sink. The alkaline phosphatase cleaves phosphate radicals from phenolphthalein diphosphate, generating free phenolphthalein, which produces a pink to red-purple color around the fecal particles in the previously colorless medium. Collaborators' recovery averages ranged from 21.7 particles (72.3%) for oat bran to 25.3 particles (84.3%) for semolina at the 30 particle spike level. Overall average background was 0.4 positive reactions per food type. The collaborators reported that the method was quick, simple, and easy to use. The method has been approved interim official first action for all 7 grain products.

  16. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  17. Managing Variety in Configure-to-Order Products - An Operational Method

    DEFF Research Database (Denmark)

    Myrodia, Anna; Hvam, Lars

    2014-01-01

    is to develop an operational method to analyze profitability of Configure-To-Order (CTO) products. The operational method consists of a four-step: analysis of product assortment, profitability analysis on configured products, market and competitor analysis and, product assortment scenarios analysis....... The proposed operational method is firstly developed based on both available literature and practitioners experience and subsequently tested on a company that produces CTO products. The results from this application are further discussed and opportunities for further research identified....

  18. Automatic test comes to focal plane array production

    Science.gov (United States)

    Skaggs, Frank L.; Barton, T. D.

    1992-08-01

    To meet the needs of military and commercial markets, the infrared focal plane array industry must develop new, effective and low cost methods of fabricating and testing imaging detectors. This paper describes Texas Instruments new concepts in automated testing and cold probe technology as they apply to volume production.

  19. Antimicrobials Products Tested or Pending Testing

    Science.gov (United States)

    The agency has completed testing of the majority of registered hospital disinfectants and tuberculocide products. The list of products can assist users in making informed choices regarding infection control in their facilities.

  20. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  1. Disintegration of sublingual tablets: proposal for a validated test method and acceptance criterion.

    Science.gov (United States)

    Weda, M; van Riet-Nales, D A; van Aalst, P; de Kaste, D; Lekkerkerker, J F F

    2006-12-01

    In the Netherlands the market share of isosorbide dinitrate 5 mg sublingual tablets is dominated by 2 products (A and B). In the last few years complaints have been received from health care professionals on product B. During patient use the disintegration of the tablet was reported to be slow and/or incomplete, and ineffectiveness was experienced. In the European Pharmacopoeia (Ph. Eur.) no requirement is present for the disintegration time of sublingual tablets. The purpose of this study was to compare the in vitro disintegration time of products A and B, and to establish a suitable test method and acceptance criterion. A and B were tested with the Ph. Eur. method described in the monograph on disintegration of tablets and capsules as well as with 3 modified tests using the same Ph. Eur. apparatus, but without movement of the basket-rack assembly. In modified test 1 and modified test 2 water was used as medium (900 ml and 50 ml respectively), whereas in modified test 3 artificial saliva was used (50 ml). In addition, disintegration was tested in Nessler tubes with 0.5 and 2 ml of water. Finally, the Ph. Eur. method was also applied to other sublingual tablets with other drug substances on the Dutch market. With modified test 3 no disintegration could be achieved within 20 min. With the Ph. Eur. method and modified tests 1 and 2 product A and B differed significantly (p disintegration times. These 3 methods were capable of discriminating between products and between batches. The time measured with the Ph. Eur. method was significantly lower compared to modified tests 1 and 2 (p tablets the disintegration time should be tested. The Ph. Eur. method is considered suitable for this test. In view of the products currently on the market and taking into consideration requirements in the United States Pharmacopeia and Japanese Pharmacopoeia, an acceptance criterion of not more than 2 min is proposed.

  2. Testing methods for antimicrobial activity of TiO2 photocatalyst

    Directory of Open Access Journals (Sweden)

    Markov Siniša L.

    2014-01-01

    Full Text Available In recent years, a lot of commercial TiO2 photocatalyst products have been developed and extensively studied for prospective and safe antimicrobial application in daily life, medicine, laboratories, food and pharmaceutical industry, waste water treatments and in development of new self-cleaning and antimicrobial materials, surfaces and paints. This paper reviews the studies published worldwide on killing microorganisms, methods for testing the antimicrobial activity, light sources and intensities, as well as calculation methods usually used when evaluating the antimicrobial properties of the TiO2-based products. Additionally, some strengths and weaknesses of the available methods for testing the antimicrobial activity of TiO2 photocatalyst products have been pointed out.[Projekat Ministarstva nauke Republike Srbije, br. III45008

  3. Potential Errors and Test Assessment in Software Product Line Engineering

    Directory of Open Access Journals (Sweden)

    Hartmut Lackner

    2015-04-01

    Full Text Available Software product lines (SPL are a method for the development of variant-rich software systems. Compared to non-variable systems, testing SPLs is extensive due to an increasingly amount of possible products. Different approaches exist for testing SPLs, but there is less research for assessing the quality of these tests by means of error detection capability. Such test assessment is based on error injection into correct version of the system under test. However to our knowledge, potential errors in SPL engineering have never been systematically identified before. This article presents an overview over existing paradigms for specifying software product lines and the errors that can occur during the respective specification processes. For assessment of test quality, we leverage mutation testing techniques to SPL engineering and implement the identified errors as mutation operators. This allows us to run existing tests against defective products for the purpose of test assessment. From the results, we draw conclusions about the error-proneness of the surveyed SPL design paradigms and how quality of SPL tests can be improved.

  4. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  5. Machine Learning Methods for Production Cases Analysis

    Science.gov (United States)

    Mokrova, Nataliya V.; Mokrov, Alexander M.; Safonova, Alexandra V.; Vishnyakov, Igor V.

    2018-03-01

    Approach to analysis of events occurring during the production process were proposed. Described machine learning system is able to solve classification tasks related to production control and hazard identification at an early stage. Descriptors of the internal production network data were used for training and testing of applied models. k-Nearest Neighbors and Random forest methods were used to illustrate and analyze proposed solution. The quality of the developed classifiers was estimated using standard statistical metrics, such as precision, recall and accuracy.

  6. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  7. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  9. Area balance method for calculation of air interchange in fire-resesistance testing laboratory for building products and constructions

    Directory of Open Access Journals (Sweden)

    Sargsyan Samvel Volodyaevich

    2014-09-01

    Full Text Available Fire-resistance testing laboratory for building products and constructions is a production room with a substantial excess heat (over 23 W/m . Significant sources of heat inside the aforementioned laboratory are firing furnace, designed to simulate high temperature effects on structures and products of various types in case of fire development. The excess heat production in the laboratory during the tests is due to firing furnaces. The laboratory room is considered as an object consisting of two control volumes (CV, in each of which there may be air intake and air removal, pollutant absorption or emission. In modeling air exchange conditions the following processes are being considered: the processes connected with air movement in the laboratory room: the jet stream in a confined space, distribution of air parameters, air motion and impurity diffusion in the ventilated room. General upward ventilation seems to be the most rational due to impossibility of using local exhaust ventilation. It is connected with the peculiarities of technological processes in the laboratory. Air jets spouted through large-perforated surface mounted at the height of 2 m from the floor level, "flood" the lower control volume, entrained by natural convective currents from heat sources upward and removed from the upper area. In order to take advantage of the proposed method of the required air exchange calculation, you must enter additional conditions, taking into account the provision of sanitary-hygienic characteristics of the current at the entrance of the service (work area. Exhaust air containing pollutants (combustion products, is expelled into the atmosphere by vertical jet discharge. Dividing ventilated rooms into two control volumes allows describing the research process in a ventilated room more accurately and finding the air exchange in the lab room during the tests on a more reasonable basis, allowing to provide safe working conditions for the staff without

  10. Estimation of soil properties and free product volume from baildown tests

    International Nuclear Information System (INIS)

    Zhu, J.L.; Parker, J.C.; Lundy, D.A.; Zimmerman, L.M.

    1993-01-01

    Baildown tests, involving measurement of water and free product levels in a monitoring well after bailing, are often performed at spill sites to estimate the oil volume per unit area -- which the authors refer to as ''oil specific volume.'' Spill volume is estimated by integrating oil specific volume over the areal domain of the spill. Existing methods for interpreting baildown tests are based on grossly simplistic approximations of soil capillary properties that cannot accurately describe the transient well response. A model for vertical equilibrium oil distributions based on the van Genuchten capillary model has been documented and verified in the laboratory and in the field by various authors. The model enables oil specific volume and oil transmissivity to be determined as functions of well product thickness. This paper describes a method for estimating van Genuchten capillary parameters, as well as aquifer hydraulic conductivity, from baildown tests. The results yield the relationships of oil specific volume and oil transmissivity to apparent product thickness, which may be used, in turn, to compute spill volume and to model free product plume movement and free product recovery. The method couples a finite element model for radial flow of oil and water to a well with a nonlinear parameter estimation algorithm. Effects of the filter pack around the well in the fluid level response are considered explicitly by the model. The method, which is implemented in the program BAILTEST, is applied to field data from baildown tests. The results indicate that hydrographs of water and oil levels are accurately described by the model

  11. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  12. Analysis of differential method for compensating fluctuations in product thickness when radiometric testing

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Kvasnitsa, M.S.

    1979-01-01

    Given are the estimates of information capabilities of the differential method for measuring radiation flux in radiation defectoscopy as well as efficiency of application of automatic radiation facilities to control taking into account the statistical regularities of product thickness fluctuations. Dependences of signal to noise ratio on the regularities of product thickness fluctuations have been found and optimization, on this basis, of the design and parameters of processing instrumentation was carried out. It is shown, that with 60-80 mm interval of product thickness fluctuations correlation (welded joints) it is expedient to use two radiation beams with their crossing on a mean product plane. When the interval of correlation of thickness fluctuations is great it is effective to use the geometry of radioscopy with parallel radiation beams. This permits to use only one radiation source without significant reducing the compensation efficiency, that in most cases simplifies the development and application of radiometric systems. Thus the efficiency of applying the differential method for radiation beam detection to compensate product thickness fluctuations is primarily determined by statistical regularities of the given fluctuations. The account of the regularities in the development of the processing instrumentation results in the most complete extraction of useful information, containing in the radiation beams being detected

  13. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers procedures for determining water absorption, bulk density, apparent porosity, and apparent specific gravity of fired unglazed whiteware products. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. 46 CFR 57.06-2 - Production test plate interval of testing.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-2 Production test plate interval of testing. (a) At least one... 46 Shipping 2 2010-10-01 2010-10-01 false Production test plate interval of testing. 57.06-2... follows: (1) When the extent of welding on a single vessel exceeds 50 lineal feet of either or both...

  15. Advantages and limitations of common testing methods for antioxidants.

    Science.gov (United States)

    Amorati, R; Valgimigli, L

    2015-05-01

    Owing to the importance of antioxidants in the protection of both natural and man-made materials, a large variety of testing methods have been proposed and applied. These include methods based on inhibited autoxidation studies, which are better followed by monitoring the kinetics of oxygen consumption or of the formation of hydroperoxides, the primary oxidation products. Analytical determination of secondary oxidation products (e.g. carbonyl compounds) has also been used. The majority of testing methods, however, do not involve substrate autoxidation. They are based on the competitive bleaching of a probe (e.g. ORAC assay, β-carotene, crocin bleaching assays, and luminol assay), on reaction with a different probe (e.g. spin-trapping and TOSC assay), or they are indirect methods based on the reduction of persistent radicals (e.g. galvinoxyl, DPPH and TEAC assays), or of inorganic oxidizing species (e.g. FRAP, CUPRAC and Folin-Ciocalteu assays). Yet other methods are specific for preventive antioxidants. The relevance, advantages, and limitations of these methods are critically discussed, with respect to their chemistry and the mechanisms of antioxidant activity. A variety of cell-based assays have also been proposed, to investigate the biological activity of antioxidants. Their importance and critical aspects are discussed, along with arguments for the selection of the appropriate testing methods according to the different needs.

  16. PID Testing Method Suitable for Process Control of Solar Cells Mass Production

    Directory of Open Access Journals (Sweden)

    Xianfang Gou

    2015-01-01

    Full Text Available Voltage bias of several hundred volts which are applied between solar cells and module frames may lead to significant power losses, so-called potential-induced degradation (PID, in normal photovoltaic (PV installations system. Modules and minimodules are used to conduct PID test of solar cells. The test procedure is time consuming and of high cost, which cannot be used as process monitoring method during solar cells fabrication. In this paper, three kinds of test including minimodule, Rsh, and V-Q test are conducted on solar cells or wafers with SiNx of different refractive index. All comparisons between test results of Rsh, V-Q, and minimodule tests have shown equal results. It is shown that Rsh test can be used as quality inspection of solar cells and V-Q test of coated wafer can be used as process control of solar cells.

  17. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  18. In vitro methods for evaluating skin hydration under diapers and incontinence products.

    Science.gov (United States)

    Tate, M L; Wright, A S

    2017-11-01

    Excessive skin hydration from wearing wet undergarments, such as infant diapers and adult incontinence products, has been historically problematic. Skin damage occurs from wetness (urine) and limited product breathability. Evaporative water loss has been measured on adult arms (armband method) or infant torsos (on-baby method), after wearing a saline-insulted diaper product. The current study developed a reliable in vitro method of evaluating diaper and incontinence products for improvements in skin dryness. A simulated skin substrate was applied to a heated mechanical arm or baby torso. A disposable diaper or incontinence product was wrapped around the arm or baby torso, and loaded with saline. Hydration of the simulated skin was measured by evaporimetry and compared with clinical data from adult armband evaluations. The heated mechanical arm and baby torso accurately distinguished products for skin dryness. Eight diaper products were evaluated and compared to human test results. The torso in vitro and mechanical arm evaluations demonstrated strong correlations to human epidermal water loss evaluations, with repeatable results. Additionally, the bench test has been used for adult incontinence products, and it proved to differentiate those products as well as infant products. A rapid and reliable means of evaluation has been developed, and it is predictive of human subject testing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. 16 CFR 1509.6 - Component-spacing test method.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Component-spacing test method. 1509.6 Section 1509.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... applied to the wedge perpendicular to the plane of the crib side. ...

  20. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  1. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. A well test analysis method accounting for pre-test operations

    International Nuclear Information System (INIS)

    Silin, D.B.; Tsang, C.-F.

    2003-01-01

    We propose to use regular monitoring data from a production or injection well for estimating the formation hydraulic properties in the vicinity of the wellbore without interrupting the operations. In our approach, we select a portion of the pumping data over a certain time interval and then derive our conclusions from analysis of these data. A distinctive feature of the proposed approach differing it form conventional methods is in the introduction of an additional parameter, an effective pre-test pumping rate. The additional parameter is derived based on a rigorous asymptotic analysis of the flow model. Thus, we account for the non-uniform pressure distribution at the beginning of testing time interval caused by pre-test operations at the well. By synthetic and field examples, we demonstrate that deviation of the matching curve from the data that is usually attributed to skin and wellbore storage effects, can also be interpreted through this new parameter. Moreover, with our method, the data curve is matched equally well and the results of the analysis remain stable when the analyzed data interval is perturbed, whereas traditional methods are sensitive to the choice of the data interval. A special efficient minimization procedure has been developed for searching the best fitting parameters. We enhanced our analysis above with a procedure of estimating ambient reservoir pressure and dimensionless wellbore radius. The methods reported here have been implemented in code ODA (Operations Data Analysis). A beta version of the code is available for free testing and evaluation to interested parties

  3. Extending product modeling methods for integrated product development

    DEFF Research Database (Denmark)

    Bonev, Martin; Wörösch, Michael; Hauksdóttir, Dagný

    2013-01-01

    Despite great efforts within the modeling domain, the majority of methods often address the uncommon design situation of an original product development. However, studies illustrate that development tasks are predominantly related to redesigning, improving, and extending already existing products...... and PVM methods, in a presented Product Requirement Development model some of the individual drawbacks of each method could be overcome. Based on the UML standard, the model enables the representation of complex hierarchical relationships in a generic product model. At the same time it uses matrix....... Updated design requirements have then to be made explicit and mapped against the existing product architecture. In this paper, existing methods are adapted and extended through linking updated requirements to suitable product models. By combining several established modeling techniques, such as the DSM...

  4. Using non-parametric methods in econometric production analysis

    DEFF Research Database (Denmark)

    Czekaj, Tomasz Gerard; Henningsen, Arne

    2012-01-01

    by investigating the relationship between the elasticity of scale and the farm size. We use a balanced panel data set of 371~specialised crop farms for the years 2004-2007. A non-parametric specification test shows that neither the Cobb-Douglas function nor the Translog function are consistent with the "true......Econometric estimation of production functions is one of the most common methods in applied economic production analysis. These studies usually apply parametric estimation techniques, which obligate the researcher to specify a functional form of the production function of which the Cobb...... parameter estimates, but also in biased measures which are derived from the parameters, such as elasticities. Therefore, we propose to use non-parametric econometric methods. First, these can be applied to verify the functional form used in parametric production analysis. Second, they can be directly used...

  5. 77 FR 3559 - Energy Conservation Program for Consumer Products: Test Procedures for Refrigerators...

    Science.gov (United States)

    2012-01-25

    ... Long-Time and Variable Defrost Test Method To Fully Capture Energy Use for Temperature Recovery D... product classes. 55 FR 42845 (October 24, 1990). DOE again updated the performance standards for...: (1) Compartment temperature changes; (2) modified volume calculation methods; (3) products that...

  6. Analyses of production tests and MDT tests conducted in Mallik and Alaska methane hydrate reservoirs : what can we learn from these well tests?

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, M.; Funatsu, K.; Ouchi, H. [Japan Oil Engineering Co., Tokyo (Japan); Masuda, Y. [Tokyo Univ., Tokyo (Japan). School of Engineering; Yamamoto, K. [Japan Oil, Gas and Metals National Corp., Tokyo (Japan); Narita, H. [National Inst. of Advanced Industrial Science and Technology, Tokyo (Japan); Dallimore, S.R. [Natural Resources Canada, Ottawa, ON (Canada). Geological Survey of Canada; Collett, T.S. [United States Geological Survey, Reston, VA (United States); Hancock, S.H. [APA Petroleum Engineering Ltd., Calgary, AB (Canada)

    2008-07-01

    This paper described a series of pressure drawdown tests conducted to evaluate a modular formation dynamics tester (MDT) wireline tool. The tests were conducted at the Mallik methane hydrate (MH) reservoir as well as in MH reservoirs in Alaska over a period of several years. Production tests were also conducted to evaluate depressurization methods, and measure production and bottomhole pressure (BHP) below known MH stability pressures in order to estimate permeability and MH dissociation radius properties. The results of the tests were then history-matched using a numerical simulator. An analysis of the simulation study showed that the MDT tests were useful in estimating initial effective permeability levels in the presence of MH. However, wellbore storage erased important data used to indicate the radius of MH dissociation and effective permeability after partial MH dissociation. The study also showed that steady flow conditions must be established before obtaining solutions from history-matched production tests. Parameters accurately estimated using the MDT and production tests were outlined, and suggestions for future designs and analyses for MH reservoirs were presented. 14 refs., 7 tabs., 17 figs.

  7. Authorised allergen products for intracutaneous testing may no longer be available in Germany

    OpenAIRE

    Klimek, Ludger; Werfel, Thomas; Vogelberg, Christian; Jung, Kirsten

    2015-01-01

    Background: Beside the skin prick test, the intracutaneous test represents the most important skin test method for detecting type-1 allergies. With the incorporation of European directives into national law, test allergens used for allergy diagnosis are deemed medicinal products within the meaning of the German Medicinal Products Act (Arzneimittelgesetz) and therefore require marketing authorisation for distribution in Germany. The high costs of acquiring and maintaining these authorisations ...

  8. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  9. An accelerated test method of luminous flux depreciation for LED luminaires and lamps

    International Nuclear Information System (INIS)

    Qian, C.; Fan, X.J.; Fan, J.J.; Yuan, C.A.; Zhang, G.Q.

    2016-01-01

    Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests. - Highlights: • We develop an accelerated test method for LED luminaires and lamps. • The method is proposed based on a “Boundary Curve” concept. • The parameters of the boundary curve are extracted from LM-80 test reports. • Qualification results from the proposed method agree with ES requirements.

  10. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  11. DEVELOPMENT OF TOFU PRODUCTION METHOD WITH PROBIOTIC BACTERIA ADDITION

    Directory of Open Access Journals (Sweden)

    Dorota Zielińska

    2015-06-01

    Full Text Available The aim of the study was to develop a production method for tofu with probiotic bacteria under laboratory conditions. The works included: selection of a strain and tofu production conditions, and a storage test of the manufactured product. It was concluded that the sensory quality of tofu with the addition of different probiotic cultures did not differ significantly (p>0.01, depending on used strains and their mixtures, and the sample quality was comparable to the commercial product. It was observed that the number of Lactobacillus bacteria in study samples was the factor determining the palatability of tofu (r= 0.75. On the other hand, the sensory quality of products was significantly affected by the production method of tofu with the addition of probiotic bacteria. It was concluded that the formation of curds from soy beverage by the addition of CaSO4, followed by inoculation with Lactobacillus casei ŁOCK 0900 at the amount of 9.26 log CFU/g and incubation at temp. of 37C for 2h as well as for 20h are methods recommended for production tofu with regard to sensory qualities of the final product among all tested methods. The number of lactic acid bacteria in studied tofu samples was maintained at the high level (109-1010 CFU/g, and the number of Bifidobacterium animalis ssp lactis BB-12 bacteria did not exceed 103 CFU/g, whereas the number of Lactobacillus bacteria was equal to 108-109 CFU/g. For the period of 15 days of storage of tofu with probiotic bacteria at the temperature of 4C the number of lactic acid bacteria was maintained at the constant level of approx. 109 CFU/g. It was concluded that it is possible to produce tofu with probiotic bacteria that has acceptable sensory characteristics and a high number of lactic acid bacteria, therefore the product could be considered as a functional one.

  12. Making sense of knowledge productivity: beta testing the KP-enhancer

    NARCIS (Netherlands)

    Christiaan Stam

    2007-01-01

    Purpose – purpose of this article is to report about the progress of the development of a method that makes sense of knowledge productivity, in order to be able to give direction to knowledge management initiatives. Methodology/approach – the development and testing of the method is based on the

  13. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  14. Accelerated in-vitro release testing methods for extended-release parenteral dosage forms.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-07-01

    This review highlights current methods and strategies for accelerated in-vitro drug release testing of extended-release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in-situ depot-forming systems and implants. Extended-release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, 'real-time' in-vitro release tests for these dosage forms are often run over a long time period. Accelerated in-vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in-vitro release methods using United States Pharmacopeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended-release parenteral dosage forms, along with the accelerated in-vitro release testing methods currently employed are discussed. Accelerated in-vitro release testing methods with good discriminatory ability are critical for quality control of extended-release parenteral products. Methods that can be used in the development of in-vitro-in-vivo correlation (IVIVC) are desirable; however, for complex parenteral products this may not always be achievable. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.

  15. Accelerated in vitro release testing methods for extended release parenteral dosage forms

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J.

    2012-01-01

    Objectives This review highlights current methods and strategies for accelerated in vitro drug release testing of extended release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in situ depot-forming systems, and implants. Key findings Extended release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, “real-time” in vitro release tests for these dosage forms are often run over a long time period. Accelerated in vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in vitro release methods using United States Pharmacopoeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended release parenteral dosage forms, along with the accelerated in vitro release testing methods currently employed are discussed. Conclusions Accelerated in vitro release testing methods with good discriminatory ability are critical for quality control of extended release parenteral products. Methods that can be used in the development of in vitro-in vivo correlation (IVIVC) are desirable, however for complex parenteral products this may not always be achievable. PMID:22686344

  16. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  17. Orally inhaled drug performance testing for product development, registration, and quality control.

    Science.gov (United States)

    Lastow, Orest; Svensson, Mårten

    2014-12-01

    A DPI can be split into three different modules; device, formulation, process. These are developed in parallel, and together with the user they provide the performance of an inhalation product. During product development, these modules are evolving and changing, whereas the requirements on an inhalation product are always expressed in terms of the performance of the final commercial product. To do performance testing during development when the product is not finished presents many challenges and can be confusing and misleading. During development, the performance of the final product is typically being predicted by testing ever changing prototypes. This article describes methods and approaches to manage such development and to, during development, provide relevant predictions of the in vitro and in vivo performances of the final product.

  18. 76 FR 9777 - Recent Postings of Broadly Applicable Alternative Test Methods

    Science.gov (United States)

    2011-02-22

    ... Determination to 40 CFR part in lieu of of Nitrogen 60, subpart G, Method 7 with Oxide Emissions Standards of... test Standards of 30-day as specified in Performance for compliance test 60.46b(e). Industrial... Fiberglass Mat Industries. Production. [[Page 9780

  19. Development of post-irradiation test facility for domestic production of 99Mo

    International Nuclear Information System (INIS)

    Taguchi, Taketoshi; Yonekawa, Minoru; Kato, Yoshiaki; Kurosawa, Makoto; Nishikata, Kaori; Ishida, Takuya; Kawamata, Kazuo

    2013-01-01

    JMTR focus on the activation method. By carrying out the preliminary tests using irradiation facilities existing, and verification tests using the irradiation facility that has developed in the cutting-edge research and development strategic strengthening business, as irradiation tests towards the production of 99 Mo, we have been conducting research and development that can contribute to supply about 25% for 99 Mo demand in Japan and the stable supply of radiopharmaceutical. This report describes a summary of the status of the preliminary tests for the production of 99 Mo: Maintenance of test equipment in the facility in JMTR hot laboratory in preparation for research and development for the production of 99 Mo in JMTR and using MoO 3 pellet irradiated at Kyoto University Research Reactor Institute (KUR). (author)

  20. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 1)].

    Science.gov (United States)

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Tonooka, Hiroyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.

  1. Comparison of two methods of radiopharmaceuticals production and evaluation of their quality

    International Nuclear Information System (INIS)

    Portillo L, M.C.; Rodriguez J, S.

    1987-05-01

    Two methods for the following five radiopharmaceuticals production were compared: sulfur colloid, diethylenetriamine pentaacetic calcium salt, phyrophosphate sodium, albumin aggregated, glucoheptonate calcium salt. Radiochemical purity was determined by electrophoresis, thin-layer chromatography and bio-distribution test in mice and rats. It was concluded that chromatographic method shows better efficiency and that bio-distribution test should be done only when testing new radiopharmaceuticals because the good correlation of this test with thin-layer chromatography. (author)

  2. Maintenance Approaches for Different Production Methods

    Directory of Open Access Journals (Sweden)

    Mungani, Dzivhuluwani Simon

    2013-11-01

    Full Text Available Various production methods are used in industry to manufacture or produce a variety of products needed by industry and consumers. The nature of a product determines which production method is most suitable or cost-effective. A continuous process is typically used to produce large volumes of liquids or gases. Batch processing is often used for small volumes, such as pharmaceutical products. This paper discusses a research project to determine the relationship between maintenance approaches and production methods. A survey was done to determine to what extent three maintenance approaches reliability-centred maintenance (RCM, total productive maintenance (TPM, and business-centred maintenance (BCM are used for three different processing methods (continuous process, batch process, and a production line method.

  3. [Performance evaluation of a fluorescamine-HPLC method for determination of histamine in fish and fish products].

    Science.gov (United States)

    Kikuchi, Hiroyuki; Tsutsumi, Tomoaki; Matsuda, Rieko

    2012-01-01

    A method for the quantification of histamine in fish and fish products using tandem solid-phase extraction and fluorescence derivatization with fluorescamine was previously developed. In this study, we improved this analytical method to develop an official test method for quantification of histamine in fish and fish products, and performed a single laboratory study to validate it. Recovery tests of histamine from fillet (Thunnus obesus), and two fish products (fish sauce and salted and dried whole big-eye sardine) that were spiked at the level of 25 and 50 µg/g for T. obesus, and 50 and 100 µg/g for the two fish products, were carried out. The recoveries of histamine from the three samples tested were 88.8-99.6% with good repeatability (1.3-2.1%) and reproducibility (2.1-4.7%). Therefore, this method is acceptable for the quantification of histamine in fish and fish products. Moreover, surveillance of histamine content in food on the market was conducted using this method, and high levels of histamine were detected in some fish products.

  4. Chemometric methods and near-infrared spectroscopy applied to bioenergy production

    International Nuclear Information System (INIS)

    Liebmann, B.

    2010-01-01

    The present work examines bioenergy production from different viewpoints. The three main objectives are: (1) to reveal the relation of technology, sustainability and economy in bioenergy processes; (2) to investigate spectroscopic methods as a tool for analytical monitoring of bioenergy processes; and (3) to develop new chemometric methods for advanced analysis of spectroscopic data. At the first stage, this thesis investigates the technological, ecological, and economic features of renewable-resource-based and de-centralized bioenergy production systems. In different scenarios, small-scale bioethanol production is combined with other technologies that provide renewable energy from residuals of the bioethanol process. The general aim is to substitute fossil energy conventionally used within the bioethanol process. The investigated technologies are biogas production and straw incineration. Agricultural aspects are introduced by sustainable crop rotation concepts that reconcile food, feed, and biofuel production. The sustainability of small-scale bioethanol production in the different scenarios is quantified by an ecological footprint method, the sustainable process index, SPI, and compared to conventional fuels. The main findings are: (i) small-scaled bioethanol production can be operated with 100 % renewable energy supply, (ii) the SPI of bioethanol can be reduced up to 92 % compared to conventional fuels, (iii) a complex trade-off between ecology-of-scale and economy-of-scale is necessary. At the second stage, this thesis approaches bioenergy production processes from an analytical perspective, and presents near-infrared spectroscopy (NIR) as promising method for fast process monitoring of bioethanol production and biomass characterization. In addition, new analytical methods are presented for a fast determination of the heating value of solid biomass fuel, based on IR and NIR spectroscopy. The main findings are that NIR spectroscopy and appropriate chemometric

  5. Comparison of new immunofluorescence method for detection of soy protein in meat products with immunohistochemical, histochemical, and ELISA methods

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-01-01

    Full Text Available Soy proteins are commonly used in the food industry thanks to their technological properties. However, soy is, along with cow’s milk, eggs, wheat, peanuts, tree nuts, fish, crustaceans, and molluscs, responsible for around 90% of food allergies, and is also one of the foodstuffs that can cause anaphylaxis. The aim of this work was to compare the immunofluorescence method for the detection of soy protein in meat products purchased from the retail market with other microscopic methods (immunohistochemical and histochemical, with the ELISA reference method and with the confirmatory results. Within the research, 127 meat products purchased in the retail network were examined using the immunofluorescence method used for the detection of soy protein. The method was compared to Enzyme-Linked ImmunoSorbent Assay (ELISA, immunohistochemical, and histochemical methods. According to McNemar’s test, non-compliance between the immunofluorescence method and immunohistochemical method was low. In addition, a significant difference between the fluorescence method and ELISA (P P < 0.01 was found. The immunofluorescence method was also compared with confirmatory results. According to McNemar’s test, non-compliance between the immunofluorescence method and confirmatory results was low. The results showed the possibilities of this new method to detect the content of soy protein in meat products.

  6. Problems studied within the state research project New Methods of Nondestructive Materials Testing Using Ionizing Radiation

    International Nuclear Information System (INIS)

    Mysak, F.; Strba, J.

    1979-01-01

    A state research project is described divided into ten subprojects, viz.: New trends of ionizing radiation detection using television technology in nondestructive testing; the application of accelerators for thick-walled product testing; the atlas of butt welds of medium thicknesses; the application of radioanalytical methods in testing the wear of gearboxes and other components of instrument parts; multielemental analyses of combustion engine wear using radionuclides; the application of radioisotope methods in research into wear of antifriction bearings of trucks and railway cars; the application of radionuclides in assessing corrosion resistance of steels and corrosion protection systems; the application of radionuclide methods in improving the quality of high-grade steel production; the selection and testing of radionuclide instruments for building production control, intermediate and acceptance checks; and radioisotope methods for building machine and equipment control. (M.S.)

  7. Validation and Recommendation of Methods to Measure Biogas Production Potential of Animal Manure

    Directory of Open Access Journals (Sweden)

    C. H. Pham

    2013-06-01

    Full Text Available In developing countries, biogas energy production is seen as a technology that can provide clean energy in poor regions and reduce pollution caused by animal manure. Laboratories in these countries have little access to advanced gas measuring equipment, which may limit research aimed at improving local adapted biogas production. They may also be unable to produce valid estimates of an international standard that can be used for articles published in international peer-reviewed science journals. This study tested and validated methods for measuring total biogas and methane (CH4 production using batch fermentation and for characterizing the biomass. The biochemical methane potential (BMP (CH4 NL kg−1 VS of pig manure, cow manure and cellulose determined with the Moller and VDI methods was not significantly different in this test (p>0.05. The biodegradability using a ratio of BMP and theoretical BMP (TBMP was slightly higher using the Hansen method, but differences were not significant. Degradation rate assessed by methane formation rate showed wide variation within the batch method tested. The first-order kinetics constant k for the cumulative methane production curve was highest when two animal manures were fermented using the VDI 4630 method, indicating that this method was able to reach steady conditions in a shorter time, reducing fermentation duration. In precision tests, the repeatability of the relative standard deviation (RSDr for all batch methods was very low (4.8 to 8.1%, while the reproducibility of the relative standard deviation (RSDR varied widely, from 7.3 to 19.8%. In determination of biomethane concentration, the values obtained using the liquid replacement method (LRM were comparable to those obtained using gas chromatography (GC. This indicates that the LRM method could be used to determine biomethane concentration in biogas in laboratories with limited access to GC.

  8. Adaptive designs based on the truncated product method

    Directory of Open Access Journals (Sweden)

    Neuhäuser Markus

    2005-09-01

    Full Text Available Abstract Background Adaptive designs are becoming increasingly important in clinical research. One approach subdivides the study into several (two or more stages and combines the p-values of the different stages using Fisher's combination test. Methods Alternatively to Fisher's test, the recently proposed truncated product method (TPM can be applied to combine the p-values. The TPM uses the product of only those p-values that do not exceed some fixed cut-off value. Here, these two competing analyses are compared. Results When an early termination due to insufficient effects is not appropriate, such as in dose-response analyses, the probability to stop the trial early with the rejection of the null hypothesis is increased when the TPM is applied. Therefore, the expected total sample size is decreased. This decrease in the sample size is not connected with a loss in power. The TPM turns out to be less advantageous, when an early termination of the study due to insufficient effects is possible. This is due to a decrease of the probability to stop the trial early. Conclusion It is recommended to apply the TPM rather than Fisher's combination test whenever an early termination due to insufficient effects is not suitable within the adaptive design.

  9. 46 CFR 57.06-5 - Production toughness testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Production toughness testing. 57.06-5 Section 57.06-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-5 Production toughness testing. (a) In addition to the test specimens required by...

  10. Preliminary assessment of the waveform inversion method for interpretation of cross-well seismic data from the thermal production test, JAPEX/JNOC/GSC et al. Mallik 5L-38 gas hydrate production research well

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T. [Nagoya Univ., Nagoya (Japan). Research Center for Seismology and Volcanology; Shimizu, S. [Japan National Oil Co., Chiba (Japan); Asakawa, E. [JGI Inc., Tokyo (Japan); Kamei, R.; Matsuoka, T. [Kyoto Univ., Kyoto (Japan). Dept. of Civil and Earth Resources Engineering

    2005-07-01

    The JAPEX/JNOC/GSC et al. Mallik 3L-38 and 4L-38 test wells were subjected to repeated cross-well seismic surveys before and during the gas production test from the gas-hydrate-bearing layer at a depth of about 905 to 920 m. High-resolution velocity images in the gas-hydrate-bearing layer were obtained using the frequency-domain nonlinear waveform inversion method. An acoustic waveform inversion method was used along with the frequency-domain approach in order to detect the change in acoustic properties of the gas-hydrate-bearing layer resulting from gas production. The layered structures with small lateral heterogeneities were reconstructed by tomography analysis of preprocessed waveform data using a smaller number of source-receiver pairs. Preliminary results reveal high velocity and very high attenuation in the gas-hydrate-bearing layers. No obvious velocity decreases were noted. Information for further detailed processing was also gathered.

  11. Determination production costs using PBC method

    Directory of Open Access Journals (Sweden)

    Todić Vladimir V.

    2014-01-01

    Full Text Available Basic characteristics of modern markets make requirements in quality increasing, decreasing prices and shortening delivery of products. In the middle of this requirements are production costs for whose determination are developed many traditional and alternative methods including PBC method (Process Based Costing. This method enables precisely locating and calculating indirect production costs, and with determined direct costs enables determination of total production costs. This paper shows usage of PBC method for determination production costs for three forms of processing cutting tools.

  12. Improvement of organization and audit methods of production reserves at the enterprise

    Directory of Open Access Journals (Sweden)

    M.I. Skrypnyk

    2016-12-01

    Full Text Available The current research deals with the scientific substantiation of theoretical positions and development of practical recommendations for improving the organization and audit methodology of production reserves at an enterprise. The authors apply the methods of specification. Testing, analysis, synthesis, generalization are the basis for the improvement of the organization and audit methodology of production reserves at an enterprise. The researchers formulate the goals, objectives, information sources and basic methods used in the audit of production reserves. The article examines the main stages of the audit of production reserves and the methodology of its implementation. The algorithm of auditing of production reserves is defined. The paper examines the basic working papers of the auditor for auditing of production reserves such as the test on internal control of production reserves, the audit plan of production reserves, the audit program of production reserves, the comparative statement of inventory resultsof capital assets. These documents, in their turn, will increase the level of control and improve the quality of audit operations with production reserves. The article determines the common errors that occur during operations with production reserves tand you can avoid the errors using the developed plan, program and audit working papers used to conduct the audit of production reserves.

  13. MODERN METHODS OF REASONABLE PRODUCT SUPPLY

    Directory of Open Access Journals (Sweden)

    Anna Kulik

    2016-11-01

    Full Text Available Thesis objective is to study modern methods of product supply with the purpose to determine optimal ways for their rationalization. Since the use of reasonable practices, taking into account external and internal factors under the specific conditions of product moving from the supplier to the buyer, makes the process of product supply economically viable, i.e., low costs for product transportation, ensures fast moving products, their safety and, ultimately, results in reduction of the costs of product disposal. Methodology. The study is based on theoretical methods to study this problem. System analysis method and simulation of the ways to improve were also used in the study. Results. Addressing these issues, the concept, form and stages of product supply process organization depending on the type of product have been studied; product supply management methods based on logistics concept of “demand response”. Practical significance. Optimization of the principles and methods of product supply, factors affecting its organization will, in practice, contribute to the development of reasonable product delivery systems featured with economic efficiency of advanced technologies of product supply. Value/ originality. The analyzed methods of product supply management based on logistics concept of “demand response” can ensure maximum reduction of response time to the changes in demand by rapid stocktaking at those points of the market where the demand is expected to increase, which will allow to reduce the costs of bringing the product to the consumer.

  14. 46 CFR 54.05-16 - Production toughness testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Production toughness testing. 54.05-16 Section 54.05-16... Toughness Tests § 54.05-16 Production toughness testing. (a) For vessels of welded construction, production... welding procedures shall be the same as used in the fabrication of the vessel. From each test plate, one...

  15. Test methods for determining asphaltene stability in crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Asomaning, S. [Baker Petrolite, Sugar Land, TX (United States)

    2001-07-01

    The development of test methods for the determination of the stability of asphaltenes in crude oils was rendered necessary, due to the high cost of remediating asphaltene deposition in harsh production environments, namely the underwater systems in offshore deepwater. The Oliensis Spot Test, two saturates, aromatics, resins and asphaltenes (SARA)-based screens (the Colloidal Instability Index and Asphaltene-Resin ratio), a solvent titration method with near infrared radiation (NIR) solids detection, and live oil depressurization were used for the purposes of this study, to predict the stability of asphaltenes in crude oils with different API gravity. A complete description of the test methods was provided, and the experimental data obtained as a result was presented. Correlation with data on the deposition histories of the oils was used to validate the experimental stability data. The author discussed the effectiveness of the different tests for the prediction of the stability of asphaltenes in crude oils. The prediction of a crude oil's propensity towards asphaltene precipitation was more accurate with the Colloidal Instability Index and the solvent titration method. Live oil depressurization proved to be very effective for the prediction of the stability of asphaltenes for light oils, where most stability tests fail. tabs., 31 figs.

  16. Production of Molybdenum-99 using Neutron Capture Methods

    Energy Technology Data Exchange (ETDEWEB)

    Toth, James J; Greenwood, Lawrence R; Soderquist, Chuck Z; Wittman, Richard S; Pierson, Bruce D; Burns, Kimberly A; Lavender, Curt A; Painter, Chad L; Love, Edward F; Wall, Donald E

    2011-01-01

    Pacific Northwest National Laboratory (PNNL), operated by Battelle, has identified a reference process for the production of molybdenum-99 (99Mo) for use in a chromatographic generator to separate the daughter product, technetium-99m (99mTc). The reference process uses the neutron capture reaction of natural or enriched molybdenum oxide via the reaction 98Mo(n,γ)99Mo. The irradiated molybdenum is dissolved in an alkaline solution, whereby the molybdenum, dissolved as the molybdate anion, is loaded on a proprietary ion exchange material in the chromatographic generator. The approach of this investigation is to provide a systematic collection of technologies to make the neutron capture method for Mo-99 production economically viable. This approach would result in the development of a technetium Tc99m generator and a new type of target. The target is comprised of molybdenum, either natural or enriched, and is tailored to the design of currently operating U.S. research reactors. The systematic collection of technologies requires evaluation of new metallurgical methods to produce the target, evaluation of target geometries tailored to research reactors, and chemical methods to dissolve the irradiated target materials for use in a chromatographic generator. A Technical specification for testing the target and neutron capture method in a research reactor is also required. This report includes identification of research and demonstration activities needed to enable deployment of neutron capture production method, including irradiations of prototypic targets, chemical processing of irradiated targets, and loading and extraction tests of Mo99 and Tc99m on the sorbent material in a prototypic generator design. The prototypical generator design is based on the proprietary method and systems for isotope product generation. The proprietary methods and systems described in this report are clearly delineated with footnotes. Ultimately, the Tc-99m generator solution provided by

  17. HANDBOOK - Environmental Assessment of Construction Products - An introduction to test mehtods and other procedures related to CE-marking

    DEFF Research Database (Denmark)

    Wahlstrom, Margareta; Laine-Ylyjoki, Jutta; Rautiainen, Liisa

    2009-01-01

    regulatory limit values with test results. The starting point in this handbook is the situation where there might be a potential for a release to soil and water during the intended use of a product. This handbook presents aspects that are especially important for manufactures of construction products...... Harmonised Standards and European Technical Approvals describe methods for testing of construction products and specify the conditions for CE marking of construction products. This handbook presents an overview of the technical, regulatory and administrative framework within which CE marking of construction...... products takes place and offers guidance on the selection of test methods for assessment of release of regulated dangerous substances from construction products to soil, surface water and groundwater. The handbook includes information on how test results can be used, e.g. by regulators when comparing...

  18. Advances in product family and product platform design methods & applications

    CERN Document Server

    Jiao, Jianxin; Siddique, Zahed; Hölttä-Otto, Katja

    2014-01-01

    Advances in Product Family and Product Platform Design: Methods & Applications highlights recent advances that have been made to support product family and product platform design and successful applications in industry. This book provides not only motivation for product family and product platform design—the “why” and “when” of platforming—but also methods and tools to support the design and development of families of products based on shared platforms—the “what”, “how”, and “where” of platforming. It begins with an overview of recent product family design research to introduce readers to the breadth of the topic and progresses to more detailed topics and design theory to help designers, engineers, and project managers plan, architect, and implement platform-based product development strategies in their companies. This book also: Presents state-of-the-art methods and tools for product family and product platform design Adopts an integrated, systems view on product family and pro...

  19. Future Food Production System Development Pulling From Space Biology Crop Growth Testing in Veggie

    Science.gov (United States)

    Massa, Gioia; Romeyn, Matt; Fritsche, Ralph

    2017-01-01

    Preliminary crop testing using Veggie indicates the environmental conditions provided by the ISS are generally suitable for food crop production. When plant samples were returned to Earth for analysis, their levels of nutrients were comparable to Earth-grown ground controls. Veggie-grown produce food safety microbiology analysis indicated that space-grown crops are safe to consume. Produce sanitizing wipes were used on-orbit to further reduce risk of foodborne illness. Validation growth tests indicated abiotic challenges of insufficient or excess fluid delivery, potentially reduced air flow leading to excess water, elevated CO2 leading to physiological responses, and microorganisms that became opportunistic pathogens. As NASA works to develop future space food production, several areas of research to define these systems pull from the Veggie technology validation tests. Research into effective, reusable water delivery and water recovery methods for future food production systems arises from abiotic challenges observed. Additionally, impacts of elevated CO2 and refinement of fertilizer and light recipes for crops needs to be assessed. Biotic pulls include methods or technologies to effectively sanitize produce with few consumables and low inputs; work to understand the phytomicrobiome and potentially use it to protect crops or enhance growth; selection of crops with high harvest index and desirable flavors for supplemental nutrition; crops that provide psychosocial benefits, and custom space crop development. Planning for future food production in a deep space gateway or a deep space transit vehicle requires methods of handling and storing seeds, and ensuring space seeds are free of contaminants and long-lived. Space food production systems may require mechanization and autonomous operation, with preliminary testing initiated to identify operations and capabilities that are candidates for automation. Food production design is also pulling from Veggie logistics

  20. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  1. Production and test of the LHCb Muon Chamber

    CERN Multimedia

    2005-01-01

    - The Muon System of LHCb - The Multi-Wire Proportional Chambers for LHCb - Wire tension meter - Wire pitch measurement - Gas leakage test - Test with cosmic rays - Production and test summary - Gap gain uniformity - Production and test summary

  2. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  3. Fibrin degradation products blood test

    Science.gov (United States)

    ... behind when clots dissolve in the blood. A blood test can be done to measure these products. ... Certain medicines can change blood test results. Tell your health care provider about all the medicines you take. Your provider will tell you if you need ...

  4. Bayreuth Productivity Analysis-a method for ascertaining and improving the holistic service productivity of acute care hospitals.

    Science.gov (United States)

    Pfannstiel, Mario Alexander

    2016-01-01

    The healthcare sector is lacking a method with which hospitals can measure the extent to which they achieve their goals in terms of aggregate productivity from both patients' and employees' perspectives. The Bayreuth Productivity Analysis (BPA) provides a solution to this problem because it uses two standardized questionnaires-one for patients and one for employees-to ascertain productivity at hospitals. These questionnaires were developed in several steps according to the principles of classical test theory, and they consist of six dimensions (information, organization, climate, methods, infrastructure and equipment) of five items each. One item describes a factual situation relevant to productivity and services so that it makes a contribution to the overall productivity of a hospital. After individualized evaluation of these items, the dimensions are subjectively weighted in the two questionnaires. The productivity index thus ascertained can be considered "holistic" when all patients and employees in a hospital make a differentiated assessment and weigh off each of the dimensions. In conclusion, the BPA constitutes a simple yet practicable method to ascertain and improve the holistic service productivity of hospitals. Copyright © 2014 John Wiley & Sons, Ltd.

  5. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  6. The influence of plants on productivity : A critical assessment of research findings and test methods

    NARCIS (Netherlands)

    Bakker, I; van der Voordt, Theo

    2010-01-01

    Purpose
    This paper aims to review available research into the impact of plants on people and labour productivity in order to test a number of hypotheses and the reliability and validity of “evidence based” statements.
    Methodology
    An extended literature review has been conducted of

  7. Gradient-based methods for production optimization of oil reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Suwartadi, Eka

    2012-07-01

    Production optimization for water flooding in the secondary phase of oil recovery is the main topic in this thesis. The emphasis has been on numerical optimization algorithms, tested on case examples using simple hypothetical oil reservoirs. Gradientbased optimization, which utilizes adjoint-based gradient computation, is used to solve the optimization problems. The first contribution of this thesis is to address output constraint problems. These kinds of constraints are natural in production optimization. Limiting total water production and water cut at producer wells are examples of such constraints. To maintain the feasibility of an optimization solution, a Lagrangian barrier method is proposed to handle the output constraints. This method incorporates the output constraints into the objective function, thus avoiding additional computations for the constraints gradient (Jacobian) which may be detrimental to the efficiency of the adjoint method. The second contribution is the study of the use of second-order adjoint-gradient information for production optimization. In order to speedup convergence rate in the optimization, one usually uses quasi-Newton approaches such as BFGS and SR1 methods. These methods compute an approximation of the inverse of the Hessian matrix given the first-order gradient from the adjoint method. The methods may not give significant speedup if the Hessian is ill-conditioned. We have developed and implemented the Hessian matrix computation using the adjoint method. Due to high computational cost of the Newton method itself, we instead compute the Hessian-timesvector product which is used in a conjugate gradient algorithm. Finally, the last contribution of this thesis is on surrogate optimization for water flooding in the presence of the output constraints. Two kinds of model order reduction techniques are applied to build surrogate models. These are proper orthogonal decomposition (POD) and the discrete empirical interpolation method (DEIM

  8. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  9. Production integrated nondestructive testing of composite materials and material compounds - an overview

    Science.gov (United States)

    Straß, B.; Conrad, C.; Wolter, B.

    2017-03-01

    Composite materials and material compounds are of increasing importance, because of the steadily rising relevance of resource saving lightweight constructions. Quality assurance with appropriate Nondestructive Testing (NDT) methods is a key aspect for reliable and efficient production. Quality changes have to be detected already in the manufacturing flow in order to take adequate corrective actions. For materials and compounds the classical NDT methods for defectoscopy, like X-ray and Ultrasound (US) are still predominant. Nevertheless, meanwhile fast, contactless NDT methods, like air-borne ultrasound, dynamic thermography and special Eddy-Current techniques are available in order to detect cracks, voids, pores and delaminations but also for characterizing fiber content, distribution and alignment. In Metal-Matrix Composites US back-scattering can be used for this purpose. US run-time measurements allow the detection of thermal stresses at the metal-matrix interface. Another important area is the necessity for NDT in joining. To achieve an optimum material utilization and product safety as well as the best possible production efficiency, there is a need for NDT methods for in-line inspection of the joint quality while joining or immediately afterwards. For this purpose EMAT (Electromagnetic Acoustic Transducer) technique or Acoustic Emission testing can be used.

  10. Radiological testing of products containing radioactivity

    International Nuclear Information System (INIS)

    Dixon, D.W.; Knight, A.

    1980-01-01

    Consumer products containing radioactive substances are tested by NRPB to determine how much radioactive material is likely to be released from a product if it is misused or accidentally damaged. Such testing is briefly described with particular reference to ionisation chamber smoke detectors, liquid crystal display watches illuminated with gaseous tritium light sources and anti-static brushes containing polonium-210 in the form of ceramic microspheres. (U.K.)

  11. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  12. Soft wheat and flour products methods review: solvent retention capacity equation correction

    Science.gov (United States)

    This article discusses the results of a significant change to calculations made within AACCI Approved methods 56-10 and 56-11, the Alkaline Water Retention Capacity (AWRC) test and the Solvent Retention Capacity (SRC) test. The AACCI Soft Wheat and Flour Products Technical Committee reviewed propos...

  13. E-learning platform for automated testing of electronic circuits using signature analysis method

    Science.gov (United States)

    Gherghina, Cǎtǎlina; Bacivarov, Angelica; Bacivarov, Ioan C.; Petricǎ, Gabriel

    2016-12-01

    Dependability of electronic circuits can be ensured only through testing of circuit modules. This is done by generating test vectors and their application to the circuit. Testability should be viewed as a concerted effort to ensure maximum efficiency throughout the product life cycle, from conception and design stage, through production to repairs during products operating. In this paper, is presented the platform developed by authors for training for testability in electronics, in general and in using signature analysis method, in particular. The platform allows highlighting the two approaches in the field namely analog and digital signature of circuits. As a part of this e-learning platform, it has been developed a database for signatures of different electronic components meant to put into the spotlight different techniques implying fault detection, and from this there were also self-repairing techniques of the systems with this kind of components. An approach for realizing self-testing circuits based on MATLAB environment and using signature analysis method is proposed. This paper analyses the benefits of signature analysis method and simulates signature analyzer performance based on the use of pseudo-random sequences, too.

  14. Standard test method for gamma energy emission from fission products in uranium hexafluoride and uranyl nitrate solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of gamma energy emitted from fission products in uranium hexafluoride (UF6) and uranyl nitrate solution. It is intended to provide a method for demonstrating compliance with UF6 specifications C 787 and C 996 and uranyl nitrate specification C 788. 1.2 The lower limit of detection is 5000 MeV Bq/kg (MeV/kg per second) of uranium and is the square root of the sum of the squares of the individual reporting limits of the nuclides to be measured. The limit of detection was determined on a pure, aged natural uranium (ANU) solution. The value is dependent upon detector efficiency and background. 1.3 The nuclides to be measured are106Ru/ 106Rh, 103Ru,137Cs, 144Ce, 144Pr, 141Ce, 95Zr, 95Nb, and 125Sb. Other gamma energy-emitting fission nuclides present in the spectrum at detectable levels should be identified and quantified as required by the data quality objectives. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its us...

  15. Proceedings of the specialist meeting on Mo-99 production by (n, γ) method

    International Nuclear Information System (INIS)

    Ishitsuka, Etsuo; Ishihara, Masahiro; Suzuki, Masahide

    2012-07-01

    This report summarizes the documents presented in the Specialist Meeting on 99 Mo Production by (n, γ) Method, which was held on March 9 to 10, 2012, at the Yurakucho Asahi Hall in Tokyo, hosted by Japan Atomic Energy Agency. The objective of the meeting is to exchange the information of current status, future plan for the 99 Mo production, and to make a discussion of “How to cooperate” in each research and test reactor. There were 27 participants from Poland, Kazakhstan, Indonesia, Thailand, Malaysia, Netherlands, Korea and Japan. As a result of this meeting, it was recognized that to push forward the development of 99 Mo production by (n, γ) method is necessary for the future steady supply of 99 Mo. Moreover, an irradiation test using the high density MoO 3 pellet developed by the Japan Atomic Energy Agency was proposed from a viewpoint of a merit for the common irradiation target in each research and test reactor. (author)

  16. Plasma processing methods for hydrogen production

    International Nuclear Information System (INIS)

    Mizeraczyk, J.; Jasinski, M.

    2016-01-01

    In the future a transfer from the fossil fuel-based economy to hydrogen-based economy is expected. Therefore the development of systems for efficient H_2 production becomes important. The several conventional methods of mass-scale (or central) H_2 production (methane, natural gas and higher hydrocarbons reforming, coal gasification reforming) are well developed and their costs of H_2 production are acceptable. However, due to the H_2 transport and storage problems the small-scale (distributed) technologies for H_2 production are demanded. However, these new technologies have to meet the requirement of producing H_2 at a production cost of $(1-2)/kg(H_2) (or 60 g(H_2)/kWh) by 2020 (the U.S. Department of Energy's target). Recently several plasma methods have been proposed for the small-scale H_2 production. The most promising plasmas for this purpose seems to be those generated by gliding, plasmatron and nozzle arcs, and microwave discharges. In this paper plasma methods proposed for H_2 production are briefly described and critically evaluated from the view point of H_2 production efficiency. The paper is aiming at answering a question if any plasma method for the small-scale H_2 production approaches such challenges as the production energy yield of 60 g(H_2)/kWh, high production rate, high reliability and low investment cost. (authors)

  17. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    Science.gov (United States)

    Silva, F.; Sousa, S. P. B.; Arezes, P.; Swuste, P.; Ribeiro, M. C. S.; Baptista, J. S.

    2015-05-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.

  18. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    International Nuclear Information System (INIS)

    Silva, F; Sousa, S P B; Ribeiro, M C S; Arezes, P; Swuste, P; Baptista, J S

    2015-01-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health and Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field. (paper)

  19. New engine method for biodiesel cetane number testing

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2008-01-01

    Full Text Available Substitution of fossil fuels with fuels that come from part renewable sources has been a subject of many studies and researches in the past decade. Considering the higher cost and limits of production resources, a special attention is focused on raising the energy efficiency of biofuel usage, mainly through optimization of the combustion process. Consequently, in biofuel applications, there is a need for determination of auto-ignition quality expressed by cetane number as a dominant characteristic that influences combustion parameters. The fact that the method for cetane number determination is comparative in nature has led us to try to develop substitute engine method for cetane number determination, by the use of the available laboratory equipment and serial, mono-cylinder engine with direct injection, DMB LDA 450. Description of the method, results of optimization of engine’s working parameters for conduction of the test and method’s Accuracy estimation are given in the paper. The paper also presents the results of domestic biodiesel fuels cetane number testing with the application of described engine method, developed at the Laboratory for internal combustion engines and fuels and lubricants of the Faculty of Mechanical Engineering from Kragujevac, Serbia.

  20. Considerations Concerning the Application of Target Costing Method in the Industry of Dairy Products

    Directory of Open Access Journals (Sweden)

    Mortură Laura Alexandra

    2017-01-01

    Full Text Available In the present conditions of the market economy, which is in full process of globalization, theadaptation of the more complex and diverse needs of the final consumers, leads to a permanentcreation and development of new products and services by the entities in order to satisfy theseneeds. Thus, the entities must apply efficient and tested methods for determining and provisioningthe costs which will result from launching new products on the market, methods which wouldsupport and ensure the best quality – price report, and which are to reduce the production costs upto a level of not affecting the quality of the final product. Such a method, according to specialtyliterature is the modern method of Target Costing.

  1. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 2)].

    Science.gov (United States)

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Yamada, Kyohei; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.

  2. The precision and torque production of common hip adductor squeeze tests used in elite football

    DEFF Research Database (Denmark)

    Light, N; Thorborg, K

    2016-01-01

    OBJECTIVES: Decreased hip adductor strength is a known risk factor for groin injury in footballers, with clinicians testing adductor strength in various positions and using different protocols. Understanding how reliable and how much torque different adductor squeeze tests produce will facilitate...... choosing the most appropriate method for future testing. In this study, the reliability and torque production of three common adductor squeeze tests were investigated. DESIGN: Test-retest reliability and cross-sectional comparison. METHODS: Twenty elite level footballers (16-33 years) without previous...

  3. New method of noncontact temperature measurement in on-line textile production

    Science.gov (United States)

    Cheng, Xianping; Song, Xing-Li; Deng, Xing-Zhong

    1993-09-01

    Based on the condition of textile production the method of infrared non-contact temperature measurement is adcpted in the heat-setting and drying heat-treatment process . This method is used to monitor the moving cloth. The temperature of the cloth is displayed rapidly and exactly. The principle of the temperature measurement is analysed theoretically in this paper. Mathematical analysis and calculation are used for introducing signal transmitting method. Adopted method of combining software with hardware the temperature is corrected and compensated with the aid of a single-chip microcomputer. The results of test indicate that the application of temperature measurement instrument provides reliable parameters in the quality control. And it is an important measure on improving the quality of products.

  4. Optimisation of production from an oil-reservoir using augmented Lagrangian methods

    Energy Technology Data Exchange (ETDEWEB)

    Doublet, Daniel Christopher

    2007-07-01

    This work studies the use of augmented Lagrangian methods for water flooding production optimisation from an oil reservoir. Commonly, water flooding is used as a means to enhance oil recovery, and due to heterogeneous rock properties, water will flow with different velocities throughout the reservoir. Due to this, water breakthrough can occur when great regions of the reservoir are still unflooded so that much of the oil may become 'trapped' in the reservoir. To avoid or reduce this problem, one can control the production so that the oil recovery rate is maximised, or alternatively the net present value (NPV) of the reservoir is maximised. We have considered water flooding, using smart wells. Smart wells with down-hole valves gives us the possibility to control the injection/production at each of the valve openings along the well, so that it is possible to control the flowregime. One can control the injection/production at all valve openings, and the setting of the valves may be changed during the production period, which gives us a great deal of control over the production and we want to control the injection/ production so that the profit obtained from the reservoir is maximised. The problem is regarded as an optimal control problem, and it is formulated as an augmented Lagrangian saddle point problem. We develop a method for optimal control based on solving the Karush-Kuhn-Tucker conditions for the augmented Lagrangian functional, a method, which to my knowledge has not been presented in the literature before. The advantage of this method is that we do not need to solve the forward problem for each new estimate of the control variables, which reduces the computational effort compared to other methods that requires the solution of the forward problem every time we find a new estimate of the control variables, such as the adjoint method. We test this method on several examples, where it is compared to the adjoint method. Our numerical experiments show

  5. Application Study of Self-balanced Testing Method on Big Diameter Rock-socketed Piles

    Directory of Open Access Journals (Sweden)

    Qing-biao WANG

    2013-07-01

    Full Text Available Through the technological test of self-balanced testing method on big diameter rock-socketed piles of broadcasting centre building of Tai’an, this paper studies and analyzes the links of the balance position selection, the load cell production and installation, displacement sensor selection and installation, loading steps, stability conditions and determination of the bearing capacity in the process of self-balanced testing. And this paper summarizes key technology and engineering experience of self-balanced testing method of big diameter rock-socketed piles and, meanwhile, it also analyzes the difficult technical problems needed to be resolved urgently at present. Conclusion of the study has important significance to the popularization and application of self-balanced testing method and the similar projects.

  6. Methodology for developing new test methods

    Directory of Open Access Journals (Sweden)

    A. I. Korobko

    2017-06-01

    Full Text Available The paper describes the methodology for developing new test methods and forming solutions for the development of new test methods. The basis of the methodology for developing new test methods is the individual elements of the system and process approaches. They contribute to the development of an effective research strategy for the object, the study of interrelations, the synthesis of an adequate model of the test method. The effectiveness of the developed test method is determined by the correct choice of the set of concepts, their interrelations and mutual influence. This allows you to solve the tasks assigned to achieve the goal. The methodology is based on the use of fuzzy cognitive maps. The question of the choice of the method on the basis of which the model for the formation of solutions is based is considered. The methodology provides for recording a model for a new test method in the form of a finite set of objects. These objects are significant for the test method characteristics. Then a causal relationship is established between the objects. Further, the values of fitness indicators and the observability of the method and metrological tolerance for the indicator are established. The work is aimed at the overall goal of ensuring the quality of tests by improving the methodology for developing the test method.

  7. Hybrid Lanczos-type product methods

    Energy Technology Data Exchange (ETDEWEB)

    Ressel, K.J. [Swiss Center for Scientific Computing, Zuerich (Switzerland)

    1996-12-31

    A general framework is proposed to construct hybrid iterative methods for the solution of large nonsymmetric systems of linear equations. This framework is based on Lanczos-type product methods, whose iteration polynomial consists of the Lanczos polynomial multiplied by some other arbitrary, {open_quotes}shadow{close_quotes} polynomial. By using for the shadow polynomial Chebyshev (more general Faber) polynomials or L{sup 2}-optimal polynomials, hybrid (Chebyshev-like) methods are incorporated into Lanczos-type product methods. In addition, to acquire spectral information on the system matrix, which is required for such a choice of shadow polynomials, the Lanczos-process can be employed either directly or in an QMR-like approach. The QMR like approach allows the cheap computation of the roots of the B-orthogonal polynomials and the residual polynomials associated with the QMR iteration. These roots can be used as a good approximation for the spectrum of the system matrix. Different choices for the shadow polynomials and their construction are analyzed. The resulting hybrid methods are compared with standard Lanczos-type product methods, like BiOStab, BiOStab({ell}) and BiOS.

  8. Production of a manual on testing methods for the use of bamboo in engineering applications

    NARCIS (Netherlands)

    Janssen, J.J.A.; Kumar, Arun; Ramanuja Rao, I.V.; Sastry, Cherla

    1998-01-01

    Tests on different properties of bamboo are being conducted in many laboratories in bamboo-growing countries. In the absence of standards that prescribe definite methods, the laboratory staff often has to improvise and innovate to find clever methods or tools. In many cases, such useful information

  9. L2 Writing in Test and Non-test Situations: Process and Product

    Directory of Open Access Journals (Sweden)

    Baraa Khuder

    2015-02-01

    Full Text Available Test writers sometimes complain they cannot perform to their true abilities because of time constraints. We therefore examined differences in terms of process and product between texts produced under test and non-test conditions. Ten L2 postgraduates wrote two argumentative essays, one under test conditions, with only forty minutes being allowed and without recourse to resources, and one under non-test conditions, with unlimited time as well as access to the Internet. Keystroke logging, screen capture software, and stimulated recall protocols were used, participants explaining and commenting on their writing processes. Sixteen writing process types were identified. Higher proportions of the processes of translation and surface revision were recorded in the test situation, while meaningful revision and evaluation were both higher in the non-test situation. There was a statistically significant difference between time allocation for different processes at different stages. Experienced teachers awarded the non-test texts a mean score of almost one point (0.8 higher. A correlational analysis examining the relationship between writing process and product quality showed that while the distribution of writing processes can have an impact on text quality in the test situation, it had no effect on the product in the non-test situation.

  10. A Comparison of Assessment Methods and Raters in Product Creativity

    Science.gov (United States)

    Lu, Chia-Chen; Luh, Ding-Bang

    2012-01-01

    Although previous studies have attempted to use different experiences of raters to rate product creativity by adopting the Consensus Assessment Method (CAT) approach, the validity of replacing CAT with another measurement tool has not been adequately tested. This study aimed to compare raters with different levels of experience (expert ves.…

  11. 49 CFR 383.133 - Testing methods.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...

  12. Method for Developing Descriptions of Hard-to-Price Products: Results of the Telecommunications Product Study

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, F.; Tonn, B.

    1999-05-01

    This report presents the results of a study to test a new method for developing descriptions of hard-to-price products. The Bureau of Labor Statistics (BLS) is responsible for collecting data to estimate price indices such as the Consumers Price Index (BLS) is responsible for collecting data to estimate price indices such as the Consumers Price Index (CPI). BLS accomplishes this task by sending field staff to places of business to price actual products. The field staff are given product checklists to help them determine whether products found today are comparable to products priced the previous month. Prices for non-comparable products are not included in the current month's price index calculations. A serious problem facing BLS is developing product checklists for dynamic product areas, new industries, and the service sector. It is difficult to keep checklists up-to-date and quite often simply to develop checklists for service industry products. Some people estimates that upwards of 50 % of US economic activity is not accounted for in the CPI

  13. Use of hot set and gel content test in QA/QC for irradiation of commercial products

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Siti Aiasah Hashim; Zulkafli Ghazali; Zarina Mohd Noor

    2006-01-01

    Currently, irradiation of polyolefin heat shrinkable tube is the main commercial activity at Alurtron. Other products include medical devices and cosmetic products. As required by the quality management system, ISO 9001:2000, Alurtron is responsible to ensure that customer received their irradiation dose as requested. At present two test methods are employed namely, hot set and gel content measurement to verify received dose . Hot set test is a physical test to determine longitudinal shrinkage of the irradiated products. Whereas gel content measurement determine to certain extend the degree of crosslinking occurred in polymeric material upon irradiation, in the customer products. Both test are routinely used to cross-check the dose required by customer. This paper outlines the correlation between hot set and gel content measurement of customer products. (Author)

  14. OCL-BASED TEST CASE GENERATION USING CATEGORY PARTITIONING METHOD

    Directory of Open Access Journals (Sweden)

    A. Jalila

    2015-10-01

    Full Text Available The adoption of fault detection techniques during initial stages of software development life cycle urges to improve reliability of a software product. Specification-based testing is one of the major criterions to detect faults in the requirement specification or design of a software system. However, due to the non-availability of implementation details, test case generation from formal specifications become a challenging task. As a novel approach, the proposed work presents a methodology to generate test cases from OCL (Object constraint Language formal specification using Category Partitioning Method (CPM. The experiment results indicate that the proposed methodology is more effective in revealing specification based faults. Furthermore, it has been observed that OCL and CPM form an excellent combination for performing functional testing at the earliest to improve software quality with reduced cost.

  15. Test Marketing in New Product Development

    Science.gov (United States)

    Klompmaker, Jay E.; And Others

    1976-01-01

    Discusses the role of test marketing in new product development, based on interviews with marketing executives. Attempts to clarify when a test market should be done, what its aims should be, and how it should be used. (JG)

  16. Agreement among the Productivity Components of Eight Presenteeism Tests in a Sample of Health Care Workers.

    Science.gov (United States)

    Thompson, Angus H; Waye, Arianna

    2018-06-01

    Presenteeism (reduced productivity at work) is thought to be responsible for large economic costs. Nevertheless, much of the research supporting this is based on self-report questionnaires that have not been adequately evaluated. To examine the level of agreement among leading tests of presenteeism and to determine the inter-relationship of the two productivity subcategories, amount and quality, within the context of construct validity and method variance. Just under 500 health care workers from an urban health area were asked to complete a questionnaire containing the productivity items from eight presenteeism instruments. The analysis included an examination of test intercorrelations, separately for amount and quality, supplemented by principal-component analyses to determine whether either construct could be described by a single factor. A multitest, multiconstruct analysis was performed on the four tests that assessed both amount and quality to test for the relative contributions of construct and method variance. A total of 137 questionnaires were completed. Agreement among tests was positive, but modest. Pearson r ranges were 0 to 0.64 (mean = 0.32) for Amount and 0.03 to 0.38 (mean = 0.25) for Quality. Further analysis suggested that agreement was influenced more by method variance than by the productivity constructs the tests were designed to measure. The results suggest that presenteeism tests do not accurately assess work performance. Given their importance in the determination of policy-relevant conclusions, attention needs to be given to test improvement in the context of criterion validity assessment. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  17. Effectiveness of creative and productive instructional method towards students' learning achievement in steel structure course

    Science.gov (United States)

    Sugiyanto, Pribadi, Supriyanto, Bambang

    2017-09-01

    The purpose of this study was to investigate the effectiveness of Creative & Productive instructional method compared with conventional method. This research was a quasi-experimental study involving all Civil Engineering students at Universitas Negeri Malang who were taking a course of Steel Structure. The students were randomly assigned to two different treatment groups, 30 students in experimental group and 37 students in the control group. It was assumed that these groups were equal in all relevant aspects; they differed only in the treatment administered. We used the t-test to test the hypothesis. The results of this research suggest that: (l) the use of Creative & Productive instructional method can significantly improve students' learning achievement, (2) the use of Creative & Productive instructional method can significantly improve students' retention, (3) students' motivation has a significant effect on their learning achievement, and (4) students' motivation has a significant effect on their retention.

  18. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  19. Brief description of out-of-pile test facilities for study in corrosion and fission product behaviour in flowing sodium

    International Nuclear Information System (INIS)

    Iizawa, K.; Sekiguchi, N.; Atsumo, H.

    1976-01-01

    The experimental methods to perform tests for study in corrosion and fission products behaviour in flowing sodium are outlined. Flow diagrams for the activated materials and fission products behaviour test loop are given

  20. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  1. QUANTIFYING SUPPLIERS’ PRODUCT QUALITY: AN EXPLORATORY PRODUCT AUDIT METHOD

    Directory of Open Access Journals (Sweden)

    S. Avakh Darestani

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT:The quality of the raw material and supplied product from suppliers plays a critical role in the quality of the final product. It has become the norm that vehicle manufacturers require their suppliers to measure product quality and service with a product audit method. Measuring quality of product is emphasised by QS9000 VDA6.5 and ISO/TS16949. From a competitive standpoint, and also to see continuous improvement in business, companies need to monitor their suppliers’ performance. Quality and delivery are two very important indicators of supplier performance. This paper presents a statistical method for measuring the quality of supplied product. This method allocates different weights to variables and attributes characteristics. Moreover, following normal distribution, the tolerance zone is divided to three regions with different scores. Therefore, the quality of suppliers’ products can be monitored based on the Product Quality Audit Score (PQAS. However, this method may be employed for organisations to monitor their raw material, work-in-process parts, and final product. It can be an indicator to monitor supplier quality behaviour.

    AFRIKAANSE OPSOMMING: Die gehalte van grondstowwe en produkte/komponente wat deur leweransiers verskaf word, speel ‘n kritiese rol in die gehalte van die finale produk. Dit het die norm geword in die motorvervaardigingsbedryf dat daar van leweransiers verwag word om hulle produkkwaliteit en –diens te meet by wyse van ‘n produkouditmetode. Die meting van produkkwaliteit word benadruk deur QS9000 VDA6.5 en ISO/TS16949. Uit ‘n mededingingshoek en ook om kontinue verbetering te monitor, is dit noodsaaklik dat leweransiers se verrigting gemeet word. Gehalte en aflewering is twee van die belangrikste indikatore van leweransiersverrigting. In hierdie artikel word ‘n statistiese model voorgehou vir die meting van die kwaliteit van die gelewerde produk. Die metode ken verskillende

  2. Determination of impurities and degradation products from veterinary medicinal products by HPLC method

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean

    2014-06-01

    Full Text Available The organic or inorganic impurities in the veterinary medicinal product can derive from starting materials, manufacturing process, incomplete purification, inappropriate storage. The acceptable levels of impurities in pharmaceuticals are estimated by comparison with standard solutions, according to the appropriate monographs. Forced degradation studies determine the stability of the method of dosage for the active compounds and for the entire finished product under excessive accelerated degradation conditions. They also provide information on degradation pathways and selectivity of analytical methods applied. The information provided by the degradation studies on the active compound and finished pharmaceutical product should demonstrate the specificity of the analytical method regarding impurities. Forced degradation studies should demonstrate that the impurities and degradation products generated do not interfere with the active compound. The current forced degradation methods consist of acid hydrolysis, basic hydrolysis, oxidation, exposure of the medicinal product to temperature and light. HPLC methods are an integral analytical instrument for the analysis of the medicinal product. The HPLC method should be able to separate, detect and quantify various specific degradation products that can appear after manufacture or storage of the medicinal product, as well as new elements appearing after synthesis. FDA and ICH guidelines recommend the enclosure of the results, including the chromatograms specific to the forced degradation-subjected medicinal product, in the documentation for marketing authorization. Using HPLC methods in forced degradation studies on medicinal products provides relevant information on the method of determination for the formulation of the medicinal product, synthesis product, packaging methods and storage.

  3. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  4. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    Science.gov (United States)

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  5. Optimization, validation and application of UV-Vis spectrophotometric-colorimetric methods for determination of trimethoprim in different medicinal products

    Directory of Open Access Journals (Sweden)

    Goran Stojković

    2016-03-01

    Full Text Available Two simple, sensitive, selective, precise, and accurate methods for determination of trimethoprim in different sulfonamide formulations intended for use in human and veterinary medicine were optimized and validated. The methods are based on the trimethoprim reaction with bromcresol green (BCG and 2,4-dinitro-1-fluorobenzene (DNFB. As extraction solvents we used 10 % N,N-dimethylacetamide in methanol and acetone for both methods, respectively. The colored products are quantified applying visible spectrophotometry at their corresponding absorption maxima. The methods were validated for linearity, sensitivity, accuracy, and precision. We tested the method applicability on four different medicinal products in tablet and powder forms containing sulfametrole and sulfamethoxazole in combination with trimethoprim. The results revealed that both methods are equally accurate with recoveries within the range 95-105 %. The obtained between-day precision for both methods, when applied on four different medicinal products, was within in the range 1.08-3.20 %. By applying the F-statistical test (P<0.05, it was concluded that for three medicinal products tested both methods are applicable with statistically insignificant difference in precision. The optimized and validated BCG and DNFB methods could find application in routine quality control of trimethoprim in various formulation forms, at different concentration levels, and in combination with different sulfonamides.

  6. Determination of γ value in equation of state of detonation products by cylinder test

    International Nuclear Information System (INIS)

    Hua Pinghuan

    2001-01-01

    A method for the determination of γ value in γ law equation of state (EOS) of detonation products (DP) by cylinder test (CT) is provided. The γ values determined by this method are not surely in agreement with that determined by free-surface velocity method (FVM), but they can be used to satisfactorily calculate DP's ability to do work

  7. Identifying and prioritizing customer requirements from tractor production by QFD method

    Directory of Open Access Journals (Sweden)

    H Taghizadeh

    2017-05-01

    Full Text Available Introduction Discovering and understanding customer needs and expectations are considered as important factors on customer satisfaction and play vital role to maintain the current activity among its competitors, proceeding and obtaining customer satisfaction which are critical factors to design a successful production; thus the successful organizations must meet their needs containing the quality of the products or services to customers. Quality Function Deployment (QFD is a technique for studying demands and needs of customers which is going to give more emphasis to the customer's interests in this way. The QFD method in general implemented various tools and methods for reaching qualitative goals; but the most important and the main tool of this method is the house of quality diagrams. The Analytic Hierarchy Process (AHP is a famous and common MADM method based on pair wise comparisons used for determining the priority of understudied factors in various studies until now. With considering effectiveness of QFD method to explicating customer's demands and obtaining customer satisfaction, generally, the researchers followed this question's suite and scientific answer: how can QFD explicate real demands and requirements of customers from tractor final production and what is the prioritization of these demands and requirements in view of customers. Accordingly, the aim of this study was to identify and prioritize the customer requirements of Massey Ferguson (MF 285 tractor production in Iran tractor manufacturing company with t- student statistical test, AHP and QFD methods. Materials and Methods Research method was descriptive and statistical population included all of the tractor customers of Tractor Manufacturing Company in Iran from March 2011 to March 2015. The statistical sample size was 171 which are determined with Cochran index. Moreover, 20 experts' opinion has been considered for determining product's technical requirements. Literature

  8. 40 CFR 80.3 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods. 80.3 Section 80.3... FUELS AND FUEL ADDITIVES General Provisions § 80.3 Test methods. The lead and phosphorus content of gasoline shall be determined in accordance with test methods set forth in the appendices to this part. [47...

  9. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Test methods. 63.1546 Section 63.1546... Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Test methods. (a) The following procedure shall....1543(a)(1) through § 63.1543(a)(9) shall be determined according to the following test methods in...

  10. A Teaching Method on Basic Chemistry for Freshman : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2003-01-01

    This report deals with a teaching method on basic chemistry for freshman. This teaching method contains guidance and instruction to how to understand basic chemistry. Pre-test and post-test have been put into practice each time. Each test was returned to students at class in the following weeks.

  11. Method for Bacterial Growth and Ammonia Production and Effect of Inhibitory Substances in Disposable Absorbent Hygiene Products.

    Science.gov (United States)

    Forsgren-Brusk, Ulla; Yhlen, Birgitta; Blomqvist, Marie; Larsson, Peter

    The purpose of this study was to evaluate a pragmatic laboratory method to provide a technique for developing incontinence products better able to reduce malodor when used in the clinical setting. Bacterial growth and bacterially formed ammonia in disposable absorbent incontinence products was measured by adding synthetic urine inoculated with bacteria to test samples cut from the crotch area of the product. The inhibitory effect's of low pH (4.5 and 4.9) and 3 antimicrobial substances-chlorhexidine, polyhexamethylene biguanide (PHMB), and thymol-at 2 concentrations each, were studied. From the initial inocula of 3.3 log colony-forming units per milliliter (cfu/mL) at baseline, the bacterial growth of the references increased to 5.0 to 6.0 log cfu/mL at 6 hours for Escherichia coli, Proteus mirabilis, and Enterococcus faecalis. At 12 hours there was a further increase to 7.0 to 8.9 log cfu/mL. Adjusting the pH of the superabsorbent in the incontinence product from 6.0 to pH 4.5 and pH 4.9 significantly (P disposable absorbent products to inhibit bacterial growth and ammonia production. This technique, we describe, provides a pragmatic method for assessing the odor-inhibiting capacity of specific incontinence products.

  12. New laboratory methods to study tooth surface coverage and interproximal plaque control by dentifrice products.

    Science.gov (United States)

    Xu, Tao; Herles, Susan M; Barnes, Virginia M

    2004-01-01

    To develop and test an in vitro tooth model for use in conjunction with laboratory methods to study interproximal effects and efficacy of dentifrices. The application of the model should offer visual evaluation of dentifrice coverage of the tooth surface, and measure dental plaque control at posterior interdental spaces with a dentifrice. The dentifrice products tested with the model were: Colgate Total 2 in 1 Toothpaste and Mouthwash (CTTM), Colgate Total dentifrice (CTD), and Colgate Regular dentifrice (CRD). Extracted human posterior teeth were disinfected, cleaned, aligned, and mounted in denture acrylic. In the area coverage method, tooth surface coverage and penetration of two different forms of dentifrice products (CTTM and CRD) were compared using digital photography. In the interproximal plaque control method, the teeth were coated with human saliva and incubated anaerobically with a mixture of representative oral bacteria for six hours at 37 degrees C. In vitro dental plaque was assessed after brushing the facial surface with one of the three dentifrice products using a clinical plaque scoring index. The area coverage method demonstrated that both dentifrice products tested covered approximately 70% of the facial tooth surface; the CTTM dentifrice coverage on the lingual tooth surface was significantly higher than the coverage for the CRD dentifrice. With the interproximal plaque control method, in the presence of an active ingredient, the CTTM dentifrice had equivalent efficacy to the CTD dentifrice. Both CTTM and CTD were significantly superior to the CRD for interproximal dental plaque control. Using the developed tooth model, two assessment methods have been shown to have the potential to demonstrate tooth surface coverage, and to assess the potential efficacy of a dentifrice for the control of interproximal dental plaque. This process can indicate potential clinical evaluation of an oral care product, and support clinical findings with controlled

  13. Radiation method for hygienization food and agriculture products

    International Nuclear Information System (INIS)

    Migdal, W.

    1995-01-01

    The irradiation of food and agriculture products have been used for several goals. That are: disinsectization, disinfection, sprout inhibition and retardation of mattering. In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in INCT (Institute of Nuclear Chemistry and Technology). The pilot plant is equipped with a small research accelerator Pilot (10 MeV, 1 kW) and and industrial unit Elektronika (10 MeV, 10 kW). This allows both laboratory and full technological scale testing of the elaborated process to be conducted. The industrial unit is being equipped with e-/X conversion target, for high density products irradiation. On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permissions for permanent treatment of spices, garlic, onions and temporary permissions for mushrooms, and potatoes. Dosimetric methods have been elaborated for the routine use at the plant. In the INCT laboratory methods for the control of e-/X treated food have been established. (author)

  14. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  15. Relevance of microbial finished product testing in food safety management

    DEFF Research Database (Denmark)

    Zwietering, Marcel H.; Jacxsens, Liesbeth; Membré, Jeanne Marie

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food......-active way by implementing an effective food safety management system. For verification activities in a food safety management system, finished product testing may however be useful. For three cases studies; canned food, chocolate and cooked ham, the relevance of testing both of finished products....... If a hazardous organism is found it means something, but absence in a limited number of samples is no guarantee of safety of a whole production batch. Finished product testing is often too little and too late. Therefore most attention should be focussed on management and control of the hazards in a more pro...

  16. WEFTA interlaboratory comparison on total lipid determination in fishery products using the Smedes method

    DEFF Research Database (Denmark)

    Horst, Karl; Oehlenschaeger, J.; Bakaert, K.

    2012-01-01

    Lipid determination by the Smedes method was tested in an interlaboratory trial performed by 9 laboratories from 7 countries belonging to the West European Fish Technologists Association Analytical Methods Working Group. 5 samples of fish and fishery products with different lipid contents, includ...

  17. 7 CFR 58.644 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...

  18. Production cost methods and data

    Science.gov (United States)

    Jeffe, R. E.; Fujita, T.

    1975-01-01

    The general gas cost equation for utility financing is presented. Modifications and assumptions made in order to apply the cost equation to hydrogen production are described. Cost data are given for various methods of hydrogen production. The cost matrix procedure is briefly discussed.

  19. Adverse reactions to cosmetics and methods of testing.

    Science.gov (United States)

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  20. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  1. Quality estimation methods used in product life cycle

    OpenAIRE

    M. Dudek-Burlikowska; D. Szewieczek

    2007-01-01

    Purpose: A new approach to quality control in production company with usage of quality research methods has been presented.Design/methodology/approach: The possibility of usage of quality research methods are connected with continuous quality improvement of pre-production, production and after-production spheres of organization. Interdependence of the quality research methods and product life cycle has been taken into account.Findings: At the present time the enterprises should integrate qua...

  2. Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Young, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brown, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-05-10

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

  3. A Systematic Optimization Design Method for Complex Mechatronic Products Design and Development

    Directory of Open Access Journals (Sweden)

    Jie Jiang

    2018-01-01

    Full Text Available Designing a complex mechatronic product involves multiple design variables, objectives, constraints, and evaluation criteria as well as their nonlinearly coupled relationships. The design space can be very big consisting of many functional design parameters, structural design parameters, and behavioral design (or running performances parameters. Given a big design space and inexplicit relations among them, how to design a product optimally in an optimization design process is a challenging research problem. In this paper, we propose a systematic optimization design method based on design space reduction and surrogate modelling techniques. This method firstly identifies key design parameters from a very big design space to reduce the design space, secondly uses the identified key design parameters to establish a system surrogate model based on data-driven modelling principles for optimization design, and thirdly utilizes the multiobjective optimization techniques to achieve an optimal design of a product in the reduced design space. This method has been tested with a high-speed train design. With comparison to others, the research results show that this method is practical and useful for optimally designing complex mechatronic products.

  4. Methodically finding solutions of equipments for carrying out experiments in materials testing and research. Pt. 2

    International Nuclear Information System (INIS)

    Findeisen, D.; Nachtweide, D.; Kuntze, G.

    1983-01-01

    In comparison with the development of industrial products the development of test equipments is of special kind, which is demonstrated by methodical proceeding for finding solutions and by potentialities for technical design and production of test equipment engineering. Some general principles are turned out and explained by several realized examples of design belonging to the sphere of materials testing in den Federal Institute of Materials Testing (BAM) representative of other problems. User are large scientific institutes independent of university, scientific institutes as members of university just as test stands and quality control offices of industrial works. (orig.) [de

  5. Characterisation and full-scale production testing of multifunctional surfaces for deep drawing applications

    DEFF Research Database (Denmark)

    Godi, Alessandro; Grønbæk, J.; De Chiffre, Leonardo

    2017-01-01

    assisted polishing. Advanced methods are employed to characterise the tools' surface topographies, detecting the surface features and analysing them separately according to their specific function. Four different multifunctional dies as well as two un-textured references are selected for testing. The tests......Full-scale deep drawing tests using tools featuring multifunctional surfaces are carried out in a production environment. Multifunctional tools display regularly spaced, transversal grooves for lubricant retention obtained by hard-turning, separated by smooth bearing plateaus realized by robot...

  6. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  7. 30 CFR 36.41 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 36.41 Section 36.41 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Requirements § 36.41 Testing methods. Mobile diesel-powered transportation equipment submitted for...

  8. Knowledge productivity : designing and testing a method to diagnose knowledge productivity and plan for enhancement

    NARCIS (Netherlands)

    Stam, C.D.

    2007-01-01

    Our economy has changed from an industrial into a knowledge economy in which knowledge productivity has become the main challenge. The lack of appropriate techniques to reveal knowledge productivity hinders organizations to design effective policies aiming at improving knowledge-based performance.

  9. Adverse reactions to cosmetics and methods of testing

    Directory of Open Access Journals (Sweden)

    Nigam P

    2009-01-01

    Full Text Available Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test, eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test, mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test, and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test. Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  10. 16 CFR 1213.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... orientation”). Then gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the... Figure 2 of this part into the portion of the boundary of the opening to be tested, with the plane of the...

  11. Fission product separations testing

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, D.A.; DePaoli, S.M. [Oak Ridge National Lab., TN (United States)

    1997-10-01

    The initial goal of this task is to adequately understand the treatment needs of the end user in treating contaminated wastewater. These needs are then incorporated into the evaluation of new treatment technologies for wastewater treatment. Pertinent information is than supplied to the end user so that they can select a preferred process to meet their waste treatment needs. New sorbent materials, ion-exchange materials, or other processes of interest to DOE`s Office of Environmental Restoration (EM-40) will be evaluated initially for the removal of {sup 90}Sr and {sup 137}Cs from groundwater and process wastewater. Laboratory studies will strive to obtain a quantitative understanding of the behavior of these new materials and to evaluate their sorption efficiency in reference to a standard benchmark treatment technique. Testing of the new materials will begin by conducting scoping tests where new treatment materials are compared with standard, commercially available materials in batch shaker tests. Experimental data for the most promising sorbents will then be fit to an equilibrium model so that nuclide sorption can be predicted for variable wastewater composition. Additional testing with actual wastewater will be conducted with two or three of the most effective treatment methods. Once batch testing of a treatment method is completed, dynamic column tests will be performed to validate the equilibrium sorption model and to obtain the defining column operating parameters for scaling up the technology.

  12. Research on test of product based on spatial sampling criteria and variable step sampling mechanism

    Science.gov (United States)

    Li, Ruihong; Han, Yueping

    2014-09-01

    This paper presents an effective approach for online testing the assembly structures inside products using multiple views technique and X-ray digital radiography system based on spatial sampling criteria and variable step sampling mechanism. Although there are some objects inside one product to be tested, there must be a maximal rotary step for an object within which the least structural size to be tested is predictable. In offline learning process, Rotating the object by the step and imaging it and so on until a complete cycle is completed, an image sequence is obtained that includes the full structural information for recognition. The maximal rotary step is restricted by the least structural size and the inherent resolution of the imaging system. During online inspection process, the program firstly finds the optimum solutions to all different target parts in the standard sequence, i.e., finds their exact angles in one cycle. Aiming at the issue of most sizes of other targets in product are larger than that of the least structure, the paper adopts variable step-size sampling mechanism to rotate the product specific angles with different steps according to different objects inside the product and match. Experimental results show that the variable step-size method can greatly save time compared with the traditional fixed-step inspection method while the recognition accuracy is guaranteed.

  13. Perspectives and strategies of alternative methods used in the risk assessment of personal care products.

    Science.gov (United States)

    Quantin, P; Thélu, A; Catoire, S; Ficheux, H

    2015-11-01

    Risk assessment for personal care products requires the use of alternative methods since animal testing is now totally banned. Some of these methods are effective and have been validated by the "European Union Reference Laboratory for alternatives to animal testing"; but there is still a need for development and implementation of methods for specific endpoints. In this review, we have focused on dermal risk assessment because it is the prime route of absorption and main target organ for personal care products. Within this field, various areas must be assessed: irritation, sensitisation and toxicokinetic. Personal care product behaviour after use by the consumer and potential effects on the environment are also discussed. The purpose of this review is to show evolution and the prospects of alternative methods for safety dermal assessment. Assessment strategies must be adapted to the different chemical classes of substances studied but also to the way in which they are used. Finally, experimental and theoretical technical parameters that may impact on measured effects have been identified and discussed. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. A Comparison of Methods to Test Mediation and Other Intervening Variable Effects

    Science.gov (United States)

    MacKinnon, David P.; Lockwood, Chondra M.; Hoffman, Jeanne M.; West, Stephen G.; Sheets, Virgil

    2010-01-01

    A Monte Carlo study compared 14 methods to test the statistical significance of the intervening variable effect. An intervening variable (mediator) transmits the effect of an independent variable to a dependent variable. The commonly used R. M. Baron and D. A. Kenny (1986) approach has low statistical power. Two methods based on the distribution of the product and 2 difference-in-coefficients methods have the most accurate Type I error rates and greatest statistical power except in 1 important case in which Type I error rates are too high. The best balance of Type I error and statistical power across all cases is the test of the joint significance of the two effects comprising the intervening variable effect. PMID:11928892

  15. Composition and methods for improved fuel production

    Science.gov (United States)

    Steele, Philip H.; Tanneru, Sathishkumar; Gajjela, Sanjeev K.

    2015-12-29

    Certain embodiments of the present invention are configured to produce boiler and transportation fuels. A first phase of the method may include oxidation and/or hyper-acidification of bio-oil to produce an intermediate product. A second phase of the method may include catalytic deoxygenation, esterification, or olefination/esterification of the intermediate product under pressurized syngas. The composition of the resulting product--e.g., a boiler fuel--produced by these methods may be used directly or further upgraded to a transportation fuel. Certain embodiments of the present invention also include catalytic compositions configured for use in the method embodiments.

  16. Modern methods of eddy-current testing for avoiding material mistakes

    International Nuclear Information System (INIS)

    Baumgartner, H.

    1987-01-01

    The conservation of raw materials and energy as a general goal in all fields is the reason why also in mechanical engineering and motor vehicle engineering, cross-sectional areas are reduced. The advantages thus obtained, - lower weight and lower manufacturing cost-, on the other hand require special core on the part of the manufacturer who has to enhance the testing activities in order to assure the appropriate structural conditions, also in mass production. Any wrong thermal treatment, or use of wrong material which remain undetected, may have disastrous effects. The eddy-current testing method now offers a mature procedure of quality assurance and is shown to be highly reliable with the attached computing equipment, guaranteeing 100 p.c. testing of manufactured goods. (orig.) [de

  17. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  18. Standard test method for determining the susceptibility to intergranular corrosion of 5XXX series Aluminum alloys by mass loss after exposure to nitric acid (NAMLT Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method describes a procedure for constant immersion intergranular corrosion testing of 5XXX series aluminum alloys. 1.2 This test method is applicable only to wrought products. 1.3 This test method covers type of specimen, specimen preparation, test environment, and method of exposure. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Sequential testing scheme for the assessment of the side-effects of plant protection products on the predatory bug Orius laevigatus

    NARCIS (Netherlands)

    Veire, Van de M.; Sterk, G.; Staaij, van der M.; Ramakers, P.M.J.; Tirry, L.

    2002-01-01

    This paper describes a number of test methods, to beused in a sequential scheme, for testing the side-effects ofplant protection products on anthocorid bugs. Orius laevigatuswas used as test species. A `worst case' laboratory method wasdeveloped for evaluating the effect on mortality of the

  20. Collider Dipole Magnet test program from development through production

    International Nuclear Information System (INIS)

    Bailey, R.E.

    1991-01-01

    Verification of CDM performance, reliability, and magnet production processes will be accomplished during the development phase of the program. Key features of this program include thorough in process testing of magnet subassemblies, verification of the magnetic field quality, and demonstration of the CDM performance during the formal qualification program. Reliability demonstration of the CDM design includes component tests and an accelerated life test program. Prototype magnet phase will address achievement of magnet performance goals through a program of fabrications, test, analysis, redesign as required and procurement of modified parts for a second fabrication run. This process would be repeated again if necessary, and would conclude with a final design for the production magnets. Production process validation will address the effects that key production processes have upon magnet performance, using the magnets produced during the Preproduction phase

  1. A production throughput forecasting system in an automated hard disk drive test operation using GRNN

    Energy Technology Data Exchange (ETDEWEB)

    Samattapapong, N.; Afzulpurkar, N.

    2016-07-01

    The goal of this paper is to develop a pragmatic system of a production throughput forecasting system for an automated test operation in a hard drive manufacturing plant. The accurate forecasting result is necessary for the management team to response to any changes in the production processes and the resources allocations. In this study, we design a production throughput forecasting system in an automated test operation in hard drive manufacturing plant. In the proposed system, consists of three main stages. In the first stage, a mutual information method was adopted for selecting the relevant inputs into the forecasting model. In the second stage, a generalized regression neural network (GRNN) was implemented in the forecasting model development phase. Finally, forecasting accuracy was improved by searching the optimal smoothing parameter which selected from comparisons result among three optimization algorithms: particle swarm optimization (PSO), unrestricted search optimization (USO) and interval halving optimization (IHO). The experimental result shows that (1) the developed production throughput forecasting system using GRNN is able to provide forecasted results close to actual values, and to projected the future trends of production throughput in an automated hard disk drive test operation; (2) An IHO algorithm performed as superiority appropriate optimization method than the other two algorithms. (3) Compared with current forecasting system in manufacturing, the results show that the proposed system’s performance is superior to the current system in prediction accuracy and suitable for real-world application. The production throughput volume is a key performance index of hard disk drive manufacturing systems that need to be forecast. Because of the production throughput forecasting result is useful information for management team to respond to any changing in production processes and resources allocation. However, a practically forecasting system for

  2. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    Science.gov (United States)

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  3. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  4. Optimization and Improvement of Test Processes on a Production Line

    Science.gov (United States)

    Sujová, Erika; Čierna, Helena

    2018-06-01

    The paper deals with increasing processes efficiency at a production line of cylinder heads of engines in a production company operating in the automotive industry. The goal is to achieve improvement and optimization of test processes on a production line. It analyzes options for improving capacity, availability and productivity of processes of an output test by using modern technology available on the market. We have focused on analysis of operation times before and after optimization of test processes at specific production sections. By analyzing measured results we have determined differences in time before and after improvement of the process. We have determined a coefficient of efficiency OEE and by comparing outputs we have confirmed real improvement of the process of the output test of cylinder heads.

  5. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Development of Dissolution Test Method for Drotaverine ... Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test .... test by Prism 4.0 software, and differences between ...

  6. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility.

  7. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    International Nuclear Information System (INIS)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub

    2016-01-01

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility

  8. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  9. Introduction of a method for presenting health-based impacts of the emission from products, based on emission measurements of materials used in manufacturing of the products

    Energy Technology Data Exchange (ETDEWEB)

    Jørgensen, Rikke Bramming, E-mail: rikke.jorgensen@iot.ntnu.no

    2013-11-15

    A method for presenting the health impact of emissions from furniture is introduced, which could be used in the context of environmental product declarations. The health impact is described by the negative indoor air quality potential, the carcinogenic potential, the mutagenic and reprotoxic potential, the allergenic potential, and the toxicological potential. An experimental study of emissions from four pieces of furniture is performed by testing both the materials used for production of the furniture and the complete piece of furniture, in order to compare the results gained by adding emissions of material with results gained from testing the finished piece of furniture. Calculating the emission from a product based on the emission from materials used in the manufacture of the product is a new idea. The relation between calculated results and measured results from the same products differ between the four pieces of furniture tested. Large differences between measured and calculated values are seen for leather products. More knowledge is needed to understand why these differences arise. Testing materials allows us to compare different suppliers of the same material. Four different foams and three different timber materials are tested, and the results vary between materials of the same type. If the manufacturer possesses this type of knowledge of the materials from the subcontractors it could be used as a selection criterion according to production of low emission products. -- Highlights: • A method for presenting health impact of emissions is introduced. • An experimental study of emissions from four pieces of furniture is performed. • Health impact is calculated based on sum of contribution from the materials used. • Calculated health impact is compared to health impact of the manufactured product. • The results show that health impact could be useful in product development and for presentation in EPDs.

  10. Standard test method for determination of "microwave safe for reheating" for ceramicware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method determines the suitability of ceramicware for use in microwave re-heating applications. Microwave ovens are mainly used for reheating and defrosting frozen foods. Severe thermal conditions can occur while reheating foods. Typical reheating of foods requires one to five min. in the microwave at the highest power settings. Longer periods than five minutes are considered cooking. Cooking test methods and standards are not addressed in this test method. Most ceramicware is minimally absorbing of the microwave energy and will not heat up significantly. Unfortunately there are some products that absorb microwave energy to a greater extent and can become very hot in the microwave and pose a serious hazard. Additionally, the nature of microwave heating introduces radiation in a non-uniform manner producing temperature differentials in the food being cooked as well as the ceramic container holding it. The differential may become great enough to thermal shock the ware and create dangerous condition...

  11. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  12. 40 CFR 63.465 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.465 Section 63.465... Halogenated Solvent Cleaning § 63.465 Test methods. (a) Except as provided in paragraphs (f) and (g) of this... Reference Method 307 in appendix A of this part. (b) Except as provided in paragraph (g) of this section for...

  13. Lubricant Test Methods for Sheet Metal Forming

    DEFF Research Database (Denmark)

    Bay, Niels; Olsson, David Dam; Andreasen, Jan Lasson

    2008-01-01

    appearing in different sheet forming operations such as stretch forming, deep drawing, ironing and punching. The laboratory tests have been especially designed to model the conditions in industrial production. Application of the tests for evaluating new lubricants before introducing them in production has......Sheet metal forming of tribologically difficult materials such as stainless steel, Al-alloys and Ti-alloys or forming in tribologically difficult operations like ironing, punching or deep drawing of thick plate requires often use of environmentally hazardous lubricants such as chlorinated paraffin...... oils in order to avoid galling. The present paper describes a systematic research in the development of new, environmentally harmless lubricants focusing on the lubricant testing aspects. A system of laboratory tests has been developed to study the lubricant performance under the very varied conditions...

  14. The behavior of fission products during nuclear rocket reactor tests

    International Nuclear Information System (INIS)

    Bokor, P.C.; Kirk, W.L.; Bohl, R.J.

    1991-01-01

    Fission product release from nuclear rocket propulsion reactor fuel is an important consideration for nuclear rocket development and application. Fission product data from the last six reactors of the Rover program are collected in this paper to provide as basis for addressing development and testing issues. Fission product loss from the fuel will depend on fuel composition and reactor design and operating parameters. During ground testing, fission products can be contained downstream of the reactor. The last Rover reactor tested, the Nuclear Furnance, was mated to an effluent clean-up system that was effective in preventing the discharge of fission products into the atmosphere

  15. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. 46 CFR 163.003-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 163.003-27 Section 163... examination. (a) General. Each ladder produced under Coast Guard approval must be tested in accordance with... for effective monitoring throughout the production schedule. (e) Visual examination. The visual...

  17. 46 CFR 160.017-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 160.017-27 Section 160... examination. (a) General. Each ladder manufactured under Coast Guard approval must be tested in accordance... for effective monitoring throughout the production schedule. (e) Visual examination. The visual...

  18. Relevance of microbial finished product testing in food safety management

    NARCIS (Netherlands)

    Zwietering, M.H.; Jacxsens, L.; Membre, J.M.; Nauta, M.; Peterz, M.

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food.

  19. Standard Test Method for Measuring Reaction Rates by Analysis of Barium-140 From Fission Dosimeters

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes two procedures for the measurement of reaction rates by determining the amount of the fission product 140Ba produced by the non-threshold reactions 235U(n,f), 241Am(n,f), and 239Pu(n,f), and by the threshold reactions 238U(n,f), 237Np(n,f), and 232Th(n,f). 1.2 These reactions produce many fission products, among which is 140Ba, having a half-life of 12.752 days. 140Ba emits gamma rays of several energies; however, these are not easily detected in the presence of other fission products. Competing activity from other fission products requires that a chemical separation be employed or that the 140Ba activity be determined indirectly by counting its daughter product 140La. This test method describes both procedure (a), the nondestructive determination of 140Ba by the direct counting of 140La several days after irradiation, and procedure (b), the chemical separation of 140Ba and the subsequent counting of 140Ba or its daughter 140La. 1.3 With suitable techniques, fission neutron fl...

  20. ConocoPhillips Gas Hydrate Production Test

    Energy Technology Data Exchange (ETDEWEB)

    Schoderbek, David [ConocoPhillips Co., Houston, TX (United States); Farrell, Helen [ConocoPhillips Co., Houston, TX (United States); Howard, James [ConocoPhillips Co., Houston, TX (United States); Raterman, Kevin [ConocoPhillips Co., Houston, TX (United States); Silpngarmlert, Suntichai [ConocoPhillips Co., Houston, TX (United States); Martin, Kenneth [ConocoPhillips Co., Houston, TX (United States); Smith, Bruce [ConocoPhillips Co., Houston, TX (United States); Klein, Perry [ConocoPhillips Co., Houston, TX (United States)

    2013-06-30

    Work began on the ConocoPhillips Gas Hydrates Production Test (DOE award number DE-NT0006553) on October 1, 2008. This final report summarizes the entire project from January 1, 2011 to June 30, 2013.

  1. Standard test method for compressive (crushing) strength of fired whiteware materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers two test procedures (A and B) for the determination of the compressive strength of fired whiteware materials. 1.2 Procedure A is generally applicable to whiteware products of low- to moderately high-strength levels (up to 150 000 psi or 1030 MPa). 1.3 Procedure B is specifically devised for testing of high-strength ceramics (over 100 000 psi or 690 MPa). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Overview of the 2006-2008 JOGMEC/NRCan/Aurora Mallik Gas Hydrate Production Test Program

    Science.gov (United States)

    Yamamoto, K.; Dallimore, S. R.

    2008-12-01

    production through depressurization method. Pre and post produciton testing geophysical logging program, geochemical analyses and monitoring tools outside of the casing also derived the supporting data for the formation responses to the depressurization. Acknowledgements: METI, MH21, JOGMEC and NRCan, Government of NWT, 2002 partners, IPM, R&D team members.

  3. Nondestructive methods for quality evaluation of livestock products.

    Science.gov (United States)

    Narsaiah, K; Jha, Shyam N

    2012-06-01

    The muscles derived from livestock are highly perishable. Rapid and nondestructive methods are essential for quality assurance of such products. Potential nondestructive methods, which can supplement or replace many of traditional time consuming destructive methods, include colour and computer image analysis, NIR spectroscopy, NMRI, electronic nose, ultrasound, X-ray imaging and biosensors. These methods are briefly described and the research work involving them for products derived from livestock is reviewed. These methods will be helpful in rapid screening of large number of samples, monitoring distribution networks, quick product recall and enhance traceability in the value chain of livestock products. With new developments in the areas of basic science related to these methods, colour, image processing, NIR spectroscopy, biosensors and ultrasonic analysis are expected to be widespread and cost effective for large scale meat quality evaluation in near future.

  4. OPTIMIZATION METHODS IN TRANSPORTATION OF FOREST PRODUCTS

    Directory of Open Access Journals (Sweden)

    Selçuk Gümüş

    2008-04-01

    Full Text Available Turkey has total of 21.2 million ha (27 % forest land. In this area, average 9 million m3 of logs and 5 million stere of fuel wood have been annually produced by the government forest enterprises. The total annual production is approximately 13million m3 Considering the fact that the costs of transporting forest products was about . 160 million TL in the year of 2006, the importance of optimizing the total costs in transportation can be better understood. Today, there is not common optimization method used at whole transportation problems. However, the decision makers select the most appropriate methods according to their aims.Comprehending of features and capacity of optimization methods is important for selecting of the most appropriate method. The evaluation of optimization methods that can be used at forest products transportation is aimed in this study.

  5. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  6. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  7. Systems and methods of storing combustion waste products

    Science.gov (United States)

    Chen, Shen-En; Wang, Peng; Miao, Xiexing; Feng, Qiyan; Zhu, Qianlin

    2016-04-12

    In one aspect, methods of storing one or more combustion waste products are described herein. Combustion waste products stored by a method described herein can include solid combustion waste products such as coal ash and/or gaseous combustion products such as carbon dioxide. In some embodiments, a method of storing carbon dioxide comprises providing a carbon dioxide storage medium comprising porous concrete having a macroporous and microporous pore structure and flowing carbon dioxide captured from a combustion flue gas source into the pore structure of the porous concrete.

  8. Empirical testing of forecast update procedure forseasonal products

    DEFF Research Database (Denmark)

    Wong, Chee Yew; Johansen, John

    2008-01-01

    Updating of forecasts is essential for successful collaborative forecasting, especially for seasonal products. This paper discusses the results of a theoretical simulation and an empirical test of a proposed time-series forecast updating procedure. It involves a two-stage longitudinal case study...... of a toy supply chain. The theoretical simulation involves historical weekly consumer demand data for 122 toy products. The empirical test is then carried out in real-time with 291 toy products. The results show that the proposed forecast updating procedure: 1) reduced forecast errors of the annual...... provided less forecast accuracy improvement and it needed a longer time to achieve relatively acceptable forecast uncertainty....

  9. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  10. Effect of Heating Method on Hydrogen Production by Biomass Gasification in Supercritical Water

    Directory of Open Access Journals (Sweden)

    Qiuhui Yan

    2014-01-01

    Full Text Available The glucose as a test sample of biomass is gasified in supercritical water with different heating methods driven by renewable solar energy. The performance comparisons of hydrogen production of glucose gasification are investigated. The relations between temperature raising speed of reactant fluid, variation of volume fraction, combustion enthalpy, and chemical exergy of H2 of the product gases with reactant solution concentration are presented, respectively. The results show that the energy quality of product gases with preheating process is higher than that with no preheating unit for hydrogen production. Hydrogen production quantity and gasification rate of glucose decrease obviously with the increase of concentration of material in no preheating system.

  11. CHARACTERISTICS OF PRODUCTS MADE OF 17-4PH STEEL BY MEANS OF 3D PRINTING METHOD

    Directory of Open Access Journals (Sweden)

    Mariusz WALCZAK

    2016-09-01

    Full Text Available The article presents the results of tests of 17-4PH steel fabricated by means of the method consisting in laser additive manufacturing (LAM – direct metal laser sintering (DMLS. This grade of steel is characterized by excellent stress corrosion resistance in the first place and is applied as construction material in chemical, aircraft, medical or mould making industry. 3D metal printing is a relatively new method enabling significant change of structural properties of these materials at printing parameters predetermined by printers manufacturer for ”offline” printing mode.In order to achieve this goal, the authors have carried out the analysis of chemical composition, SEM tests and the tests of products surface roughness. Furthermore the products have been subjected to X-ray analysis by means of computed tomography (X-ray CT. Structural discontinuities have been found in upper layer and inside printouts subjected to tests.

  12. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  13. A Bayesian reliability evaluation method with integrated accelerated degradation testing and field information

    International Nuclear Information System (INIS)

    Wang, Lizhi; Pan, Rong; Li, Xiaoyang; Jiang, Tongmin

    2013-01-01

    Accelerated degradation testing (ADT) is a common approach in reliability prediction, especially for products with high reliability. However, oftentimes the laboratory condition of ADT is different from the field condition; thus, to predict field failure, one need to calibrate the prediction made by using ADT data. In this paper a Bayesian evaluation method is proposed to integrate the ADT data from laboratory with the failure data from field. Calibration factors are introduced to calibrate the difference between the lab and the field conditions so as to predict a product's actual field reliability more accurately. The information fusion and statistical inference procedure are carried out through a Bayesian approach and Markov chain Monte Carlo methods. The proposed method is demonstrated by two examples and the sensitivity analysis to prior distribution assumption

  14. Accelerated in vitro release testing method for naltrexone loaded PLGA microspheres.

    Science.gov (United States)

    Andhariya, Janki V; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J; Shen, Jie

    2017-03-30

    The objective of the present study was to develop a discriminatory and reproducible accelerated release testing method for naltrexone loaded parenteral polymeric microspheres. The commercially available naltrexone microsphere product (Vivitrol ® ) was used as the testing formulation in the in vitro release method development, and both sample-and-separate and USP apparatus 4 methods were investigated. Following an in vitro drug stability study, frequent media replacement and addition of anti-oxidant in the release medium were used to prevent degradation of naltrexone during release testing at "real-time" (37°C) and "accelerated" (45°C), respectively. The USP apparatus 4 method was more reproducible than the sample-and-separate method. In addition, the accelerated release profile obtained using USP apparatus 4 had a shortened release duration (within seven days), and good correlation with the "real-time" release profile. Lastly, the discriminatory ability of the developed accelerated release method was assessed using compositionally equivalent naltrexone microspheres with different release characteristics. The developed accelerated USP apparatus 4 release method was able to detect differences in the release characteristics of the prepared naltrexone microspheres. Moreover, a linear correlation was observed between the "real-time" and accelerated release profiles of all the formulations investigated, suggesting that the release mechanism(s) may be similar under both conditions. These results indicate that the developed accelerated USP apparatus 4 method has the potential to be an appropriate fast quality control tool for long-acting naltrexone PLGA microspheres. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  16. Application of FT-IR Classification Method in Silica-Plant Extracts Composites Quality Testing

    Science.gov (United States)

    Bicu, A.; Drumea, V.; Mihaiescu, D. E.; Purcareanu, B.; Florea, M. A.; Trică, B.; Vasilievici, G.; Draga, S.; Buse, E.; Olariu, L.

    2018-06-01

    Our present work is concerned with the validation and quality testing efforts of mesoporous silica - plant extracts composites, in order to sustain the standardization process of plant-based pharmaceutical products. The synthesis of the silica support were performed by using a TEOS based synthetic route and CTAB as a template, at room temperature and normal pressure. The silica support was analyzed by advanced characterization methods (SEM, TEM, BET, DLS and FT-IR), and loaded with Calendula officinalis and Salvia officinalis standardized extracts. Further desorption studies were performed in order to prove the sustained release properties of the final materials. Intermediate and final product identification was performed by a FT-IR classification method, using the MID-range of the IR spectra, and statistical representative samples from repetitive synthetic stages. The obtained results recommend this analytical method as a fast and cost effective alternative to the classic identification methods.

  17. A Hierarchical Approach Using Machine Learning Methods in Solar Photovoltaic Energy Production Forecasting

    OpenAIRE

    Zhaoxuan Li; SM Mahbobur Rahman; Rolando Vega; Bing Dong

    2016-01-01

    We evaluate and compare two common methods, artificial neural networks (ANN) and support vector regression (SVR), for predicting energy productions from a solar photovoltaic (PV) system in Florida 15 min, 1 h and 24 h ahead of time. A hierarchical approach is proposed based on the machine learning algorithms tested. The production data used in this work corresponds to 15 min averaged power measurements collected from 2014. The accuracy of the model is determined using computing error statisti...

  18. Up-to-date laboratory methods for assessing the safety of perfumery and cosmetic products in the quality assurance system of the Russian Federation

    Directory of Open Access Journals (Sweden)

    A. V. Rezaykina

    2016-01-01

    Full Text Available Most of the developed countries as well as Russian Federation have a dynamically developing quality assurance system for testing the quality of laboratory tests and safety of perfumery and cosmetic products entering the market comprising a regulatory and legal framework, physical infrastructure and appropriate methodical basis and staff. At the same time, it is necessary to develop alternative test methods adjusted to perfumery and cosmetic products on a regular basis. In addition, it is necessary to optimize methods for ensuring standard sample preparation conditions in response to new forms of cosmetic products when determining microbiological, physical, chemical and toxicological characteristics, and more accurate observation methods for clinical and laboratory indices to be approved by supervising authorities.

  19. In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan

    International Nuclear Information System (INIS)

    Weidner, J.R.; Stoots, P.R.

    1990-06-01

    In 1987, the Buried Waste Program (BWP) was established within EG ampersand G Idaho, Inc., the prime contractor at INEL. Following the Environmental Restoration guidelines of the Buried Waste Program, the In Situ Vitrification Program is participating in a Remedial Investigation/Feasibility Study (RI/FS) for permanent disposal of INEL waste, in compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). This study was requested and is being funded by the Office of Technology Development of the Idaho Operations Office of DOE (DOE-ID). As part of the RI/FS, an in situ vitrification (ISV) scoping study on the treatability of mixed low-level and mixed transuranic-contaminated waste is being performed to determine the applicability of ISV to remediation of waste at SDA. In examination of the ISV process for applicability to SDA waste, this In Situ Vitrification Engineering-Scale Test ES-INEL-4 Product Characterization Test Plan identifies the following: sampling and analysis strategy; sampling procedures; methods to conduct analyses; equipment; and procedures to ensure data quality. 8 refs., 2 tabs

  20. A data base and a standard material for use in acceptance testing of low-activity waste products

    International Nuclear Information System (INIS)

    Wolf, S.F.; Ebert, W.L.; Luo, J.S.; Strachan, D.M.

    1998-04-01

    The authors have conducted replicate dissolution tests following the product consistency test (PCT) procedure to measure the mean and standard deviation of the solution concentrations of B, Na, and Si at various combinations of temperature, duration, and glass/water mass ratio. Tests were conducted with a glass formulated to be compositionally similar to low-activity waste products anticipated for Hanford to evaluate the adequacy of test methods that have been designated in privatization contracts for use in product acceptance. An important finding from this set of tests is that the solution concentrations generated in tests at 20 C will likely be too low to measure the dissolution rates of waste products reliably. Based on these results, the authors recommend that the acceptance test be conducted at 40 C. Tests at 40 C generated higher solution concentrations, were more easily conducted, and the measured rates were easily related to those at 20 C. Replicate measurements of other glass properties were made to evaluate the possible use of LRM-1 as a standard material. These include its composition, homogeneity, density, compressive strength, the Na leachability index with the ANSI/ANS 16.1 leach test, and if the glass is characteristically hazardous with the toxicity characteristic leach procedure. The values of these properties were within the acceptable limits identified for Hanford low-activity waste products. The reproducibility of replicate tests and analyses indicates that the glass would be a suitable standard material

  1. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  2. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  3. Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

    Science.gov (United States)

    Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei

    2012-01-01

    Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water

  4. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  5. Production LHC HTS power lead test results

    International Nuclear Information System (INIS)

    Tartaglia, M.A.; Carcagno, R.H.; Feher, S.; Huang, Y.; Orris, D.F.; Pischalnikov, Y.; Rabehl, R.J.; Sylvester, C.; Zbasnik, J.

    2004-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under ''standard'' and ''extreme'' operating conditions, and the stability of performance across thermal cycles

  6. Aspects on testing methods for acid attacks on concrete - further experiments

    International Nuclear Information System (INIS)

    Romben, L.

    1980-01-01

    The report presents a number of control experiments which have been performed to verify test procedures of the resistance of concrete and concrete products. A more detailed study of the calcium dissolution and the layer dissolution process has been performed. The mechanisms which control the rate of attack in the long term are discussed. The proposed method is intended for use in studying the resistance to attacks by acid water solutions. (G.B.)

  7. Predicament in detection and reporting of extended spectrum beta lactamase production in routine antibiotic susceptibility testing

    International Nuclear Information System (INIS)

    Butt, T.; Butt, E.; Raza, S.

    2017-01-01

    This descriptive and cross-sectional study was planned to determine the dilemma of inadvertent detection of extended spectrum beta lactamase (ESBL) production in Enterobacteriaceaewhen using inhibition zone size of antibiotic disks of Cefotaxime or Aztreonam in routine antibiotic susceptibility testing as recommended by Clinical Laboratory Standards Institute (CLSI). Screening and double disk tests were adopted as per CLSI. Escherichia coli ATCC 25922 was used as control strain. Among total specimens of 5346, there were 348 isolates of Escherichia coli(n=235), Klebsiella pneumonia (n=92), Klebsiella oxytoca(n=3) or Proteus mirabilus(n=18). The screening method recommended by CLSI significantly falsely detected ESBL production in 79 (32.3%) isolates (p<0.0001). ESBL detection is important as its frequency is high and treatment of the infection varies with the presence and absence of ESBL. To avoid false reporting, proper phenotypic detection of ESBL confirmatory method-like double-disk synergy test, should be used routinely. (author)

  8. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    Energy Technology Data Exchange (ETDEWEB)

    Ekstroem, P.A.; Broed, R. [Facilia AB, Stockholm, (Sweden)

    2006-05-15

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several

  9. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    International Nuclear Information System (INIS)

    Ekstroem, P.A.; Broed, R.

    2006-05-01

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several linked

  10. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  11. Method of burning petrochemical products

    Energy Technology Data Exchange (ETDEWEB)

    Sado, I

    1973-01-12

    This invention concerns a method of burning wastes such as polyvinyl chloride or other synthetic resin products and rubbers, in which wastes are burned in a nearly smokeless and odorless state. The method is characterized by a process by which petrochemical waste products are subjected to a spontaneous combustion in a casserole state in a closed combustion room in such a way that no air is supplied whatever, and subsequently the gas so generated is sent successively in an adequate amount into a separately installed second combustion room where it is reburnt at a high temperature of more than 1000 C by a jet flame from the oil burners mounted inside the combustion room. Usually, petrochemical products emanate black smoke of Ringelmann concentration of more than five and a strong odor, but in this method, particularly in the case of polyvinyl chloride the exhaust smoke has a Ringelmann smoke concentration of less than one and is almost odorless because the plastic is completely gasified by the spontaneous combustion and completely burned at 1300 to 1400/sup 0/C with oil and air in the second combustion room. When the exhaust smoke is passed through a neutralization tank to remove the chloride compounds in the smoke, the damaging contribution of the exhaust gas or smoke to the secondary pollution can be completely eliminated.

  12. PULP OBTAINING METHOD FOR PACKAGE PRODUCTION

    Directory of Open Access Journals (Sweden)

    V. V. Kuzmich

    2015-01-01

    Full Text Available The paper presents a new method for obtaining pulp which is used for production of cardboard, paper and package while using carbon dioxide and hydrazine hydrate and neutral-sulfite  shive cooking. Output increase of  the desired product can be explained by reduction in destruction of plant raw material carbohydrates during its cooking process. Quality improvement of the desired product (improvement in bleaching and output is attributed to the fact that usage of carbon dioxide and hydrazine contributes to provision of polysaccharide chain resistance to destruction due to the presence of  end links having structure of metasaccharinic and aldonic acids.The author has developed a new method for pulp obtaining on the basis of the executed investigations  and literature data.  СО2 and hydrazine hydrate have been used for obtaining pulp. Method invention concerns pulp obtaining and it can be used for paper and cardboard package manufacturing in pulp and paper industry.The method is to be carried in the following way: pulp-containing plant raw material is loaded into an autoclave and then aqua solution of sodium monosulfite containing hydrazine hydrate that constitutes 4–5 % of absolute dry pulp-containing raw material mass with liquid module 1:6–1:8 is supplied into the autoclave. The autoclave is closed for operation under pressure and the solution is carbonated under pressure which constitutes 5–8 % of absolute dry plant raw material (shover. Temperature is subsequently raised up to 180 °С in the space of 2 hours and cooking is carried out in the course of 4 hours. Usage of  the proposed method for shover cooking makes it possible to reduce monosulfite cooking process and improve qualitative characteristics and output of the desired product.  In addition to above mentioned fact there is a possibility to improve bleaching and final product output. 

  13. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  14. [Combine fats products: methodic opportunities of it identification].

    Science.gov (United States)

    Viktorova, E V; Kulakova, S N; Mikhaĭlov, N A

    2006-01-01

    At present time very topical problem is falsification of milk fat. The number of methods was considered to detection of milk fat authention and possibilities his difference from combined fat products. The analysis of modern approaches to valuation of milk fat authention has showed that the main method for detection of fat nature is gas chromatography analysis. The computer method of express identification of fat products is proposed for quick getting of information about accessory of examine fat to nature milk or combined fat product.

  15. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  16. Monte Carlo Method to Study Properties of Acceleration Factor Estimation Based on the Test Results with Varying Load

    Directory of Open Access Journals (Sweden)

    N. D. Tiannikova

    2014-01-01

    Full Text Available G.D. Kartashov has developed a technique to determine the rapid testing results scaling functions to the normal mode. Its feature is preliminary tests of products of one sample including tests using the alternating modes. Standard procedure of preliminary tests (researches is as follows: n groups of products with m elements in each start being tested in normal mode and, after a failure of one of products in the group, the remained products are tested in accelerated mode. In addition to tests in alternating mode, tests in constantly normal mode are conducted as well. The acceleration factor of rapid tests for this type of products, identical to any lots is determined using such testing results of products from the same lot. A drawback of this technique is that tests are to be conducted in alternating mode till the failure of all products. That is not always is possible. To avoid this shortcoming, the Renyi criterion is offered. It allows us to determine scaling functions using the right-censored data thus giving the opportunity to stop testing prior to all failures of products.In this work a statistical modeling of the acceleration factor estimation owing to Renyi statistics minimization is implemented by the Monte-Carlo method. Results of modeling show that the acceleration factor estimation obtained through Renyi statistics minimization is conceivable for rather large n . But for small sample volumes some systematic bias of acceleration factor estimation, which decreases with growth n is observed for both distributions (exponential and Veybull's distributions. Therefore the paper also presents calculation results of correction factors for a case of exponential distribution and Veybull's distribution.

  17. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  18. 30 CFR 250.1151 - How often must I conduct well production tests?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How often must I conduct well production tests... Requirements Well Tests and Surveys § 250.1151 How often must I conduct well production tests? (a) You must conduct well production tests as shown in the following table: You must conduct: And you must submit to...

  19. Radioactive ion beam production by the ISOL method for SPIRAL

    International Nuclear Information System (INIS)

    Landre-Pellemoine, Frederique

    2001-01-01

    This work is directly related to the SPIRAL project (Systeme de Production d'Ions Radioactifs Acceleres en Lignes) of which the start up will begin in September 2001 at GANIL (Grand Accelerateur National d'Ions Lourds) in Caen. This thesis primarily concerns the development of radioactive ion production systems (target/ion source) by the thorough study of each production stage of the ISOL (Isotopic Separation On Line) method: target and/or projectile fragmentation production, diffusion out of target material, effusion into the ion source and finally the ionization of the radioactive atoms. A bibliographical research and thermal simulations allowed us to optimize materials and the shape of the production and diffusion targets. A first target was optimized and made reliable for the radioactive noble gases production (argon, neon...). A second target dedicated to the radioactive helium production was entirely designed and realised (from the specifications to the 'off line' and 'on line' tests). Finally, a third target source system was defined for singly-charged radioactive alkaline production. The intensities of secondary beams planned for SPIRAL are presented here. A detailed study of the diffusion effusion efficiency for these various targets showed that the use of a fine microstructure carbon (grain size of 1 μm) improved the diffusion and showed the importance of thickness of the lamella for the short lived isotope effusion. (author) [fr

  20. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1993-01-01

    This report documents progress to date under a three-year contract for developing ''Methods for Testing Transport Models.'' The work described includes (1) choice of best methods for producing ''code emulators'' for analysis of very large global energy confinement databases, (2) recent applications of stratified regressions for treating individual measurement errors as well as calibration/modeling errors randomly distributed across various tokamaks, (3) Bayesian methods for utilizing prior information due to previous empirical and/or theoretical analyses, (4) extension of code emulator methodology to profile data, (5) application of nonlinear least squares estimators to simulation of profile data, (6) development of more sophisticated statistical methods for handling profile data, (7) acquisition of a much larger experimental database, and (8) extensive exploratory simulation work on a large variety of discharges using recently improved models for transport theories and boundary conditions. From all of this work, it has been possible to define a complete methodology for testing new sets of reference transport models against much larger multi-institutional databases

  1. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  2. Semiquantitative determination of mesophilic, aerobic microorganisms in cocoa products using the Soleris NF-TVC method.

    Science.gov (United States)

    Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer

    2014-01-01

    The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.

  3. Alternative Test Method for Olefins in Gasoline

    Science.gov (United States)

    This action proposes to allow for an additional alternative test method for olefins in gasoline, ASTM D6550-05. The allowance of this additional alternative test method will provide more flexibility to the regulated industry.

  4. Improving Quality of Seal Leak Test Product using Six Sigma

    Science.gov (United States)

    Luthfi Malik, Abdullah; Akbar, Muhammad; Irianto, Dradjad

    2016-02-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure.

  5. Improving Quality of Seal Leak Test Product using Six Sigma

    International Nuclear Information System (INIS)

    Malik, Abdullah Luthfi; Akbar, Muhammad; Irianto, Dradjad

    2016-01-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure. (paper)

  6. Animal DNA identification in food products and animal feed by real time polymerase chain reaction method

    Directory of Open Access Journals (Sweden)

    Людмила Мар’янівна Іщенко

    2016-11-01

    Full Text Available Approbation of diagnostic tests for species identification of beef, pork and chicken by real time polymerase chain reaction method was done. Meat food, including heat treated and animal feed, was used for research. The fact of inconsistencies was revealed for product composition of some meat products that is marked by manufacturer 

  7. Natural gas production verification tests

    International Nuclear Information System (INIS)

    1992-02-01

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) in compliance with the requirements of the National Environmental Policy Act of 1969. The Department of Energy (DOE) proposes to fund, through a contract with Petroleum Consulting Services, Inc. of Canton, Ohio, the testing of the effectiveness of a non-water based hydraulic fracturing treatment to increase gas recovery from low-pressure, tight, fractured Devonian Shale formations. Although Devonian Shales are found in the Appalachian, Michigan, and Illinois Basins, testing will be done only in the dominant, historical five state area of established production. The objective of this proposed project is to assess the benefits of liquid carbon dioxide (CO 2 )/sand stimulations in the Devonian Shale. In addition, this project would evaluate the potential nondamaging (to the formation) properties of this unique fracturing treatment relative to the clogging or chocking of pores and fractures that act as gas flow paths to the wellbore in the target gas-producing zones of the formation. This liquid CO 2 /sand fracturing process is water-free and is expected to facilitate gas well cleanup, reduce the time required for post-stimulation cleanup, and result in improved production levels in a much shorter time than is currently experienced

  8. Using non-parametric methods in econometric production analysis

    DEFF Research Database (Denmark)

    Czekaj, Tomasz Gerard; Henningsen, Arne

    Econometric estimation of production functions is one of the most common methods in applied economic production analysis. These studies usually apply parametric estimation techniques, which obligate the researcher to specify the functional form of the production function. Most often, the Cobb...... results—including measures that are of interest of applied economists, such as elasticities. Therefore, we propose to use nonparametric econometric methods. First, they can be applied to verify the functional form used in parametric estimations of production functions. Second, they can be directly used...

  9. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Development and testing of the detector for monitoring radon double-filter method

    International Nuclear Information System (INIS)

    Sevcik, P.

    2008-01-01

    Applications of physics in the study of radon transport processes in the atmosphere and of testing of atmospheric transport models require sensitive detection devices with low maintenance requirements. The most precise devices involved in the worldwide monitoring program of the atmosphere (GAW) determine volume activity of radon from a variety of daughter products of 222 Rn, resulting in a working volume of the detector (double-filter method). The purpose of this work was to explore theoretically and experimentally the possibilities and limits of a particular simple implementation of this procedure. Tested apparatus consists of a 200 dm 3 chamber (metal drum), where are developed transformation products of radon and semiconductor detector with surface barrier, which registers α particles from the conversion of daughter products 222 Rn collected on a filter at the outlet of the chamber. Testing of the apparatus takes place in the atmosphere with higher concentrations of radon. The measured variations of volume activities 222 Rn have the same character as the variations of radon concentration in the air in laboratory. Minimum detectable activity at 95% significance level is 16.0 Bq.m -3 at a pumping speed of the air 20 dm 3 .min - 1 and 13.0 Bq.m -3 at a pumping rate 24 dm 3 .min -1 . These values are still too high for using the apparatus for measuring in external atmosphere. The main limit of the apparatus is a capture of transformation products arising on the inner walls of the chamber (plate-out effect). The effectiveness of collecting 218 Po from the chamber on the filter in our measurements was only 2.8%. But we managed to increase it to about 20% by adding aerosol delivery systems into production chamber of transformation products of radon. It turns out that based on this principle can be made sensitive and continuously working monitor of radon. (author)

  11. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  12. Confidence Limits for the Indirect Effect: Distribution of the Product and Resampling Methods

    Science.gov (United States)

    MacKinnon, David P.; Lockwood, Chondra M.; Williams, Jason

    2010-01-01

    The most commonly used method to test an indirect effect is to divide the estimate of the indirect effect by its standard error and compare the resulting z statistic with a critical value from the standard normal distribution. Confidence limits for the indirect effect are also typically based on critical values from the standard normal distribution. This article uses a simulation study to demonstrate that confidence limits are imbalanced because the distribution of the indirect effect is normal only in special cases. Two alternatives for improving the performance of confidence limits for the indirect effect are evaluated: (a) a method based on the distribution of the product of two normal random variables, and (b) resampling methods. In Study 1, confidence limits based on the distribution of the product are more accurate than methods based on an assumed normal distribution but confidence limits are still imbalanced. Study 2 demonstrates that more accurate confidence limits are obtained using resampling methods, with the bias-corrected bootstrap the best method overall. PMID:20157642

  13. Phased array UT (Ultrasonic Testing) used in electricity production plants

    International Nuclear Information System (INIS)

    Kodaira, Takeshi

    2012-01-01

    Phased Array-Ultrasonic testing techniques widely used for detection and quantitative determination of the lattice defects which have been formed from fatigues or stress corrosion cracking in the materials used in the electricity production plants are presented with particular focus on the accurate determination of the defects depth (sizing) and defects discrimination applicable to weld metals of austenite stainless steels and Ni base alloys. The principle of this non-destructive analysis is briefly explained, followed by point and matrix focus phased array methods developed by Mitsubishi Heavy Industries, Ltd are explained rather in detail with illustration and the evaluated results. (S. Ohno)

  14. Product quality of parenteral vancomycin products in the United States.

    Science.gov (United States)

    Nambiar, S; Madurawe, R D; Zuk, S M; Khan, S R; Ellison, C D; Faustino, P J; Mans, D J; Trehy, M L; Hadwiger, M E; Boyne, M T; Biswas, K; Cox, E M

    2012-06-01

    In response to concerns raised about the quality of parenteral vancomycin products, the U.S. Food and Drug Administration (FDA) is investigating the product quality of all FDA-approved parenteral vancomycin products available in the United States. Product quality was evaluated independently at two FDA Office of Testing and Research (FDA-OTR) sites. In the next phase of the investigation, being done in collaboration with the National Institute of Allergy and Infectious Diseases, the in vivo activity of these products will be evaluated in an appropriate animal model. This paper summarizes results of the FDA investigation completed thus far. One site used a validated ultrahigh-pressure liquid chromatography method (OTR-UPLC), and the second site used the high-performance liquid chromatography (HPLC) method for related substances provided in the British Pharmacopeia (BP) monograph for vancomycin intravenous infusion. Similar results were obtained by the two FDA-OTR laboratories using two different analytical methods. The products tested had 90 to 95% vancomycin B (active component of vancomycin) by the BP-HPLC method and 89 to 94% vancomycin by OTR-UPLC methods. Total impurities were 5 to 10% by BP-HPLC and 6 to 11% by OTR-UPLC methods. No single impurity was >2.0%, and the CDP-1 level was ≤ 2.0% across all products. Some variability in impurity profiles of the various products was observed. No adverse product quality issues were identified with the six U.S. vancomycin parenteral products. The quality parameters of all parenteral vancomycin products tested surpassed the United States Pharmacopeia acceptance criteria. Additional testing will characterize in vivo performance characteristics of these products.

  15. Standard test method for analysis of isotopic composition of uranium in nuclear-grade fuel material by quadrupole inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method is applicable to the determination of the isotopic composition of uranium (U) in nuclear-grade fuel material. The following isotopic weight percentages are determined using a quadrupole inductively coupled plasma-mass spectrometer (Q-ICP-MS): 233U, 234U, 235U, 236U, and 238U. The analysis can be performed on various material matrices after acid dissolution and sample dilution into water or dilute nitric (HNO3) acid. These materials include: fuel product, uranium oxide, uranium oxide alloys, uranyl nitrate (UNH) crystals, and solutions. The sample preparation discussed in this test method focuses on fuel product material but may be used for uranium oxide or a uranium oxide alloy. Other preparation techniques may be used and some references are given. Purification of the uranium by anion-exchange extraction is not required for this test method, as it is required by other test methods such as radiochemistry and thermal ionization mass spectroscopy (TIMS). This test method is also described i...

  16. Some non-thermal microbial inactivation methods in dairy products

    International Nuclear Information System (INIS)

    Yangilar, F.; Kabil, E.

    2013-01-01

    During the production of dairy products, some thermal processes such as pasteurization and sterilization are used commonly to inactive microorganisms. But as a result of thermal processes, loss of nutrient and aroma, non-enzymatic browning and organoleptic differentiation especially in dairy products are seen. Because of this, alternative methods are needed to provide microbial inactivation and as major problems are caused by high temperatures, non-thermal processes are focused on. For this purpose, some methods such as high pressure (HP), pulsed light (PL), ultraviolet radiation (UV), supercritical carbon dioxide (SC-CO2) or pulsed electric field (PEF) are used in food. These methods products are processed in ambient temperature and so not only mentioned losses are minimized but also freshness and naturality of products can be preserved. In this work, we will try to be given information about methods of non-thermal microbial inactivation of dairy products. (author) [tr

  17. Industrial production of insulators using isostatic compaction method

    Energy Technology Data Exchange (ETDEWEB)

    Drugoveiko, O.P.; Ermolaeva, L.V.; Koren' , M.G.; Kreimer, B.D.; Panichev, G.I.; Ponomarev, A.P.; Rutkovskii, V.N.

    1985-07-01

    The process of shaping ceramic products from powders using isostatic compaction method is finding increasing industrial application. The production of electrical-engineering porcelain using isostatic compaction method is, according to the authors, a promising direction since this method permits one to obtain large and complex shaped products having uniform density distribution. The authors introduce an automatic isostatic compaction line at the ''Proletarii'' Factory for the production of the IOS-110-20000UKhL, T1 type insulators having the described dimensions. According to the technological process developed at the ''Elektrokeramika'' Production Complex, insulators were manufactured on the isostatic compaction line from the G-33 mass. Presspowder having a moisture content of 0.3-0.6% and a particle size of 90-160 micrometers was obtained in a spray dryer using disk spraying. The authors studied saturability by moisture of the powder obtained.

  18. The Three-Step Test-Interview (TSTI: An observation-based method for pretesting self-completion questionnaires

    Directory of Open Access Journals (Sweden)

    Tony Hak

    2008-12-01

    Full Text Available Three-Step Test-Interview (TSTI is a method for pretesting a self-completion questionnaire by first observing actual instances of interaction between the instrument and respondents (the response process before exploring the reasons for this behavior. The TSTI consists of the following three steps: 1. (Respondent-driven observation of response behavior. 2. (Interviewer-driven follow-up probing aimed at remedying gaps in observational data. 3. (Interviewer-driven debriefing aimed at eliciting experiences and opinions. We describe the aims and the techniques of these three steps, and then discuss pilot studies in which we tested the feasibility and the productivity of the TSTI by applying it in testing three rather different types of questionnaires. In the first study, the quality of a set of questions about alcohol consumption was assessed. The TSTI proved to be productive in identifying problems that resulted from a mismatch between the ‘theory’ underlying the questions on the one hand, and features of a respondent’s actual behavior and biography on the other hand. In the second pilot study, Dutch and Norwegian versions of an attitude scale, the 20-item Illegal Aliens Scale, were tested. The TSTI appeared to be productive in identifying problems that resulted from different ‘response strategies’. In the third pilot, a two-year longitudinal study, the TSTI appeared to be an effective method for documenting processes of ‘response shift’ in repeated measurements of health-related Quality of Life (QoL.

  19. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  20. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  1. Validation of a standard field test method in four countries to assess the toxicity of residues in dung of cattle treated with veterinary medical products

    NARCIS (Netherlands)

    Floate, Kevin D.; Düring, Rolf Alexander; Hanafi, Jamal; Jud, Priska; Lahr, Joost; Lumaret, Jean Pierre; Scheffczyk, Adam; Tixier, Thomas; Wohde, Manuel; Römbke, Jörg; Sautot, Lucille; Blanckenhorn, Wolf U.

    2016-01-01

    Registration of veterinary medical products includes the provision that field tests may be required to assess potential nontarget effects associated with the excretion of product residues in dung of treated livestock (phase II, tier B testing). However, regulatory agencies provide no guidance on

  2. Assessment of the microbial growth potential of slow sand filtrate with the biomass production potential test in comparison with the assimilable organic carbon method.

    Science.gov (United States)

    van der Kooij, Dick; Veenendaal, Harm R; van der Mark, Ed J; Dignum, Marco

    2017-11-15

    Slow sand filtration is the final treatment step at four surface-water supplies in the Netherlands. The microbial growth potential (MGP) of the finished water was measured with the assimilable organic carbon (AOC) method using pure cultures and the biomass production potential (BPP) test. In the BPP test, water samples were incubated untreated at 25 °C and the active-biomass concentration was measured by adenosine tri-phosphate (ATP) analysis. Addition of a river-water inoculum improved the test performance and characteristic growth and maintenance profiles of the water were obtained. The maximum ATP concentration attained within seven days and the cumulative biomass production after 14 days of incubation (BPC 14 , d ng ATP L -1 ) showed highly significant and strong linear relationships with the AOC in the slow sand filtrates. The lowest AOC and BPC 14 levels were observed in the supplies applying dune filtration without ozonation in post treatment, with AOC/TOC = 1.7 ± 0.3 μg acetate-C equivalents mg -1 C and BPC 14 /TOC = 16.3 ± 2.2 d ng ATP mg -1 C, corresponding with 1.2 ± 0.19 ng ATP mg -1 C. These characteristics may represent the lowest specific MGP of natural organic matter achievable by biofiltration at temperatures ≤20 °C. The AOC and BPC 14 concentrations in the slow sand filtrate of the supply treating lake water by ozonation with granular-activated-carbon filtration and slow sand filtration as post treatment increased with decreasing temperature. The BPP test revealed that this slow sand filtrate sampled at 2 °C contained growth-promoting compounds that were not detected with the AOC test. These observations demonstrate the utility of the BPP test for assessing the MGP of drinking water and show the performance limits of biofiltration for MGP reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Reflexion on linear regression trip production modelling method for ensuring good model quality

    Science.gov (United States)

    Suprayitno, Hitapriya; Ratnasari, Vita

    2017-11-01

    Transport Modelling is important. For certain cases, the conventional model still has to be used, in which having a good trip production model is capital. A good model can only be obtained from a good sample. Two of the basic principles of a good sampling is having a sample capable to represent the population characteristics and capable to produce an acceptable error at a certain confidence level. It seems that this principle is not yet quite understood and used in trip production modeling. Therefore, investigating the Trip Production Modelling practice in Indonesia and try to formulate a better modeling method for ensuring the Model Quality is necessary. This research result is presented as follows. Statistics knows a method to calculate span of prediction value at a certain confidence level for linear regression, which is called Confidence Interval of Predicted Value. The common modeling practice uses R2 as the principal quality measure, the sampling practice varies and not always conform to the sampling principles. An experiment indicates that small sample is already capable to give excellent R2 value and sample composition can significantly change the model. Hence, good R2 value, in fact, does not always mean good model quality. These lead to three basic ideas for ensuring good model quality, i.e. reformulating quality measure, calculation procedure, and sampling method. A quality measure is defined as having a good R2 value and a good Confidence Interval of Predicted Value. Calculation procedure must incorporate statistical calculation method and appropriate statistical tests needed. A good sampling method must incorporate random well distributed stratified sampling with a certain minimum number of samples. These three ideas need to be more developed and tested.

  4. Out-of-pile demonstration test of hydrogen production system coupling with HTTR

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Nishihara, Tetsuo; Takeda, Tetsuaki; Hada, Kazuhiko; Hayashi, Koji

    1999-01-01

    In Japan Atomic Energy Research Institute, a hydrogen production system is being designed to produce hydrogen by means of a steam reforming process of natural gas using nuclear heat (10 MW, 905degC) supplied by the High Temperature Engineering Test Reactor (HTTR). The safety principle and criteria are also being investigated in the HTTR hydrogen production system. Prior to coupling of the steam reforming system with the HTTR, an out-of-pile demonstration test was planned to confirm safety, controllability and performance of the steam reforming system under simulated operational conditions of the HTTR hydrogen production system. The out-of-pile test facility simulates key components downstream an intermediate heat exchanger of the HTTR hydrogen production system on a scale of 1 to 30 has a hydrogen production capacity of 110 Nm 3 /h using an electric heater as a reactor substitute. The test facility is under manufacturing aiming at completion in 2000 and followed by the test till 2004. In parallel to this, a hydrogen permeation test and a corrosion test of a catalyst tube of a steam reformer are being carried out to obtain data necessary for the design of the system. This report describes outline of the out-of-pile hydrogen production facility and demonstration test program for the HTTR hydrogen production system at present status. (author)

  5. Out-of-pile demonstration test of hydrogen production system coupling with HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Nishihara, Tetsuo; Takeda, Tetsuaki; Hada, Kazuhiko; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1999-07-01

    In Japan Atomic Energy Research Institute, a hydrogen production system is being designed to produce hydrogen by means of a steam reforming process of natural gas using nuclear heat (10 MW, 905degC) supplied by the High Temperature Engineering Test Reactor (HTTR). The safety principle and criteria are also being investigated in the HTTR hydrogen production system. Prior to coupling of the steam reforming system with the HTTR, an out-of-pile demonstration test was planned to confirm safety, controllability and performance of the steam reforming system under simulated operational conditions of the HTTR hydrogen production system. The out-of-pile test facility simulates key components downstream an intermediate heat exchanger of the HTTR hydrogen production system on a scale of 1 to 30 has a hydrogen production capacity of 110 Nm{sup 3}/h using an electric heater as a reactor substitute. The test facility is under manufacturing aiming at completion in 2000 and followed by the test till 2004. In parallel to this, a hydrogen permeation test and a corrosion test of a catalyst tube of a steam reformer are being carried out to obtain data necessary for the design of the system. This report describes outline of the out-of-pile hydrogen production facility and demonstration test program for the HTTR hydrogen production system at present status. (author)

  6. Testing of acoustic emission method during pressure tests of WWER-440 steam generators and pressurizers

    International Nuclear Information System (INIS)

    Wuerfl, K.; Crha, J.

    1987-01-01

    The results are discussed of measuring acoustic emission in output pressure testing of steam generators and pressurizers for WWER-440 reactors. The objective of the measurements was to test the reproducibility of measurements and to find the criterion which would be used in assessing the condition of the components during manufacture and in operation. The acoustic emission was measured using a single-channel Dunegan/Endevco apparatus and a 16-channel LOCAMAT system. The results showed that after the first assembly, during a repeat dismantle of the lids and during seal replacement, processes due to seal contacts and bolt and washer deformations were the main source of acoustic emission. A procedure was defined of how to exclude new acoustic emission sources in such cases. The acoustic emission method can be used for the diagnostics of plastic deformation processes or of crack production and propagation in components during service. (Z.M.)

  7. Continued SOFC cell and stack technology and improved production methods

    Energy Technology Data Exchange (ETDEWEB)

    Wandel, M.; Brodersen, K.; Phair, J. (and others)

    2009-05-15

    Within this project significant results are obtained on a number of very diverse areas ranging from development of cell production, metallic creep in interconnect to assembling and test of stacks with foot print larger than 500 cm2. Out of 38 milestones 28 have been fulfilled and 10 have been partly fulfilled. This project has focused on three main areas: 1) The continued cell development and optimization of manufacturing processes aiming at production of large foot-print cells, improving cell performance and development environmentally more benign production methods. 2) Stack technology - especially stacks with large foot print and improving the stack design with respect to flow geometry and gas leakages. 3) Development of stack components with emphasis on sealing (for 2G as well as 3G), interconnect (coat, architecture and creep) and test development. Production of cells with a foot print larger than 500 cm2 is very difficult due to the brittleness of the cells and great effort has been put into this topic. Eight cells were successfully produced making it possible to assemble and test a real stack thereby giving valuable results on the prospects of stacks with large foot print. However, the yield rate is very low and a significant development to increase this yield lies ahead. Several lessons were learned on the stack level regarding 'large foot print' stacks. Modelling studies showed that the width of the cell primarily is limited by production and handling of the cell whereas the length (in the flow direction) is limited by e.g. pressure drop and necessary manifolding. The optimal cell size in the flow direction was calculated to be between approx20 cm and < 30 cm. From an economical point of view the production yield is crucial and stacks with large foot print cell area are only feasible if the cell production yield is significantly enhanced. Co-casting has been pursued as a production technique due to the possibilities in large scale production

  8. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  9. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  10. Spiked environmental matrix for use as a reference material for gamma-ray spectrometry: Production and homogeneity test

    International Nuclear Information System (INIS)

    Sobiech-Matura, K.; Máté, B.; Altzitzoglou, T.

    2016-01-01

    The application of a spiking method for reference material production and its utilisation for a food matrix is presented. The raw rice powder was tested by means of γ-ray spectrometry and spiked with a "1"3"7Cs solution. The spiked material was mixed and tested for homogeneity. The future use of the rice powder reference material after the entire characterisation cycle will be for γ-ray spectrometry method validation. - Highlights: • Spiking blank substance with a traceable radioactive solution • Spiked reference material for γ-ray emitting radionuclides in food matrix • Results of the homogeneity tests are presented

  11. Analysis of standard and innovative methods for allocating upstream and refinery GHG emissions to oil products

    International Nuclear Information System (INIS)

    Moretti, Christian; Moro, Alberto; Edwards, Robert; Rocco, Matteo Vincenzo; Colombo, Emanuela

    2017-01-01

    Highlights: •Traditional and innovative methods for allocating emissions at refinery level are reviewed. •Added value has been introduced as a novel allocation method. •Hydrogen-based consistency test has been introduced to validate the allocation methods. •Consistent allocation methods assign negative refinery emissions to heavy products. -- Abstract: Alternative fuel policies need accurate and transparent methods to find the embedded carbon intensity of individual refinery products. This study investigates different ways of allocating greenhouse gases emissions deriving from refining and upstream crude oil supply. Allocation methods based on mass, energy content, economic value and, innovatively, added-value, are compared with the marginal refining emissions calculated by CONCAWE’s linear-programming model to the average EU refinery, which has been adopted as reference in EU legislation. Beside the most important transportation fuels (gasoline, diesel, kerosene/jet fuel and heavy fuel oil), the analysis extends to petroleum coke and refinery hydrogen. Moreover, novel criteria, based on the implications due to hydrogen usage by each fuel pathway, have been introduced to test the consistency of the analyzed approaches. It is found that only two economic-based allocation methods are consistent with the introduced criteria. These two methods also give negative refinery emissions for heavy products, which is coherent with the marginal emissions calculated through the CONCAWE refinery model. The recommended allocation methods are transparent and use only publicly available statistical data, so they may be useful not only for future EU legislation, but also in jurisdictions where a representative refinery model is not available.

  12. 76 FR 69481 - Testing and Labeling Pertaining to Product Certification

    Science.gov (United States)

    2011-11-08

    ... 1107 Testing and Labeling Pertaining to Product Certification; Final Rule #0;#0;Federal Register / Vol... Pertaining to Product Certification AGENCY: Consumer Product Safety Commission. ACTION: Final rule. SUMMARY... that the product complies with the certification requirements under section 14(a) of the Consumer...

  13. 16 CFR 1500.43a - Method of test for flashpoint of volatile flammable materials.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Method of test for flashpoint of volatile flammable materials. 1500.43a Section 1500.43a Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION... shall intersect the plane of the underside of the cover. The cover is also provided with an orifice...

  14. Novel Method of Production Decline Analysis

    Science.gov (United States)

    Xie, Shan; Lan, Yifei; He, Lei; Jiao, Yang; Wu, Yong

    2018-02-01

    ARPS decline curves is the most commonly used in oil and gas field due to its minimal data requirements and ease application. And prediction of production decline which is based on ARPS analysis rely on known decline type. However, when coefficient index are very approximate under different decline type, it is difficult to directly recognize decline trend of matched curves. Due to difficulties above, based on simulation results of multi-factor response experiments, a new dynamic decline prediction model is introduced with using multiple linear regression of influence factors. First of all, according to study of effect factors of production decline, interaction experimental schemes are designed. Based on simulated results, annual decline rate is predicted by decline model. Moreover, the new method is applied in A gas filed of Ordos Basin as example to illustrate reliability. The result commit that the new model can directly predict decline tendency without needing recognize decline style. From arithmetic aspect, it also take advantage of high veracity. Finally, the new method improves the evaluation method of gas well production decline in low permeability gas reservoir, which also provides technical support for further understanding of tight gas field development laws.

  15. 76 FR 2930 - Market Test of Experimental Product: “Gift Cards”

    Science.gov (United States)

    2011-01-18

    ... POSTAL SERVICE Market Test of Experimental Product: ``Gift Cards'' AGENCY: Postal Service \\TM\\. ACTION: Notice. SUMMARY: The Postal Service gives notice of a market test of an experimental product in... notice pursuant to 39 U.S.C. 3641(c)(1) that it will begin a market test of its ``Gift Cards...

  16. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  17. Design and Testing of Subsystems for Mo-99 Production

    Energy Technology Data Exchange (ETDEWEB)

    Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Bailey, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-01

    Argonne National Laboratory, in cooperation with Los Alamos National Laboratory, is developing technology with NorthStar Medical Technologies to produce 99Mo from the γ,n reaction on a 100Mo target in an electron accelerator. During production runs and thermal testing of the helium-cooled target, it became obvious that a production-scale beam-line configuration would need a collimator to protect the target from accidental beam misplacement or a beam-profile change. A prototype high-power collimator and beam stop were designed and fabricated. Testing indicated that they will be able to operate at full power in the production-scale accelerator.

  18. Comparison of three techniques for production goat lentivirus antigen used in the agar gel immunodifusion test

    Directory of Open Access Journals (Sweden)

    Raymundo Rizaldo Pinheiro

    2005-12-01

    Full Text Available The Caprine Arthritis Encephalitis (CAE is a disease who cause considerable economic losses, including loss in the milk production and reduction of the useful life of the animal. In the diagnosis of this disease the agar gel immunodifusion test (AGID is used worldwide as the selection test. The objective of thid work was to test three different concentrations of bovine fetal serum (BFS in the production of the antigen (Ag for the diagnosis of the CAE virus (CAEV, to verify amongst the three methods the most efficient concentration and which the antigen concentration of the antigen produced is appropriate for the test. The method of the AMICON and the concentration of the Ag for dialysis was indicated, however the system AMICON, despite the implantation costs, promoted minor loss of antigen, little time expense in the processing and greater simplicity. With relation to the amount of BFS placed after the viral inoculation it was verified that 5% of BFS the amount that presented better resulted. The antigen concentration 100 times was more indicated, therefore it allowed the diagnosis of the CAEV for two proteins (gp 135 and p28. The concentration of the Ag for precipitation/ultracentrifugation, used for imunoenzimatic tests, did not present resulted satisfactory used in the AGID.

  19. Quantitative concept tests of organic premium meat products

    OpenAIRE

    Chrysochou , Polymeros; Krystallis Krontalis, Athanasios

    2015-01-01

    This report is part of WP6 of the SUMMER project. The aim is to investigate how consumers perceive organic premium products and if they are willing to pay a price premium for these products. We conducted an experiment with 426 Danish consumers, in which we manipulate production method (organic vs. conventional), premium production (premium vs. non-premium) and extrinsic quality (high vs. low) across three meat products (pork, beef and chicken). Our findings show that consumers perceive organi...

  20. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  1. Biodiesel production methods of rubber seed oil: a review

    Science.gov (United States)

    Ulfah, M.; Mulyazmi; Burmawi; Praputri, E.; Sundari, E.; Firdaus

    2018-03-01

    The utilization of rubber seed as raw material of biodiesel production is seen highly potential in Indonesia. The availability of rubber seeds in Indonesia is estimated about 5 million tons per annum, which can yield rubber seed oil about 2 million tons per year. Due to the demand of edible oils as a food source is tremendous and the edible oil feedstock costs are far expensive to be used as fuel, production of biodiesel from non-edible oils such as rubber seed is an effective way to overcome all the associated problems with edible oils. Various methods for producing biodiesel from rubber seed oil have been reported. This paper introduces an optimum condition of biodiesel production methods from rubber seed oil. This article was written to be a reference in the selection of methods and the further development of biodiesel production from rubber seed oil. Biodiesel production methods for rubber seed oils has been developed by means of homogeneous catalysts, heterogeneous catalysts, supercritical method, ultrasound, in-situ and enzymatic processes. Production of biodiesel from rubber seed oil using clinker loaded sodium methoxide as catalyst is very interesting to be studied and developed further.

  2. 75 FR 28335 - Testing and Labeling Pertaining to Product Certification

    Science.gov (United States)

    2010-05-20

    ... Product Certification; Proposed Rule #0;#0;Federal Register / Vol. 75, No. 97 / Thursday, May 20, 2010.... CPSC-2010-0038] RIN 3041-AC71 Testing and Labeling Pertaining to Product Certification AGENCY: Consumer... also address labeling of consumer products to show that the product complies with certification...

  3. Method of storing solidification products

    International Nuclear Information System (INIS)

    Tani, Yutaro.

    1985-01-01

    Purpose: To enable to efficiently and satisfactorily cool and store solidification products of liquid wastes generated from the reactor spent fuel reprocessing process by a simple facility. Method: Liquid wastes generated from the reactor spent fuel reprocessing process are caused to flow from the upper opening to the inside of a spherical canistor. The opening of the spherical canistor is welded with a lid by a remote control and the liquid wastes are tightly sealed within the spherical canistor as glass solidification products. Spherical canistors having the solidification products tightly sealed therein are sent into and stored in a hopper by the remote control. Further, a blower is driven upon storing to suck cooling air from the cooling air intake port to the inside of the hopper to absorb the decay heat of radioactive materials in the solidification products and the air is discharged from the duct and through the stack to the atmosphere. (Kawakami, Y.)

  4. 46 CFR 154.182 - Contiguous hull structure: Production weld test.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Contiguous hull structure: Production weld test. 154.182... Equipment Hull Structure § 154.182 Contiguous hull structure: Production weld test. If a portion of the contiguous hull structure is designed for a temperature colder than −34 °C (−30 °F) and is not part of the...

  5. A comparison of immunotoxic effects of nanomedicinal products with regulatory immunotoxicity testing requirements

    Directory of Open Access Journals (Sweden)

    Giannakou C

    2016-06-01

    Full Text Available Christina Giannakou,1,2 Margriet VDZ Park,1 Wim H de Jong,1 Henk van Loveren,1,2 Rob J Vandebriel,1 Robert E Geertsma1 1Centre for Health Protection, National Institute for Public Health and the Environment (RIVM, Bilthoven, 2Department of Toxicogenomics, Maastricht University, Maastricht, the Netherlands Abstract: Nanomaterials (NMs are attractive for biomedical and pharmaceutical applications because of their unique physicochemical and biological properties. A major application area of NMs is drug delivery. Many nanomedicinal products (NMPs currently on the market or in clinical trials are most often based on liposomal products or polymer conjugates. NMPs can be designed to target specific tissues, eg, tumors. In virtually all cases, NMPs will eventually reach the immune system. It has been shown that most NMs end up in organs of the mononuclear phagocytic system, notably liver and spleen. Adverse immune effects, including allergy, hypersensitivity, and immunosuppression, have been reported after NMP administration. Interactions of NMPs with the immune system may therefore constitute important side effects. Currently, no regulatory documents are specifically dedicated to evaluate the immunotoxicity of NMs or NMPs. Their immunotoxicity assessment is performed based on existing guidelines for conventional substances or medicinal products. Due to the unique properties of NMPs when compared with conventional medicinal products, it is uncertain whether the currently prescribed set of tests provides sufficient information for an adequate evaluation of potential immunotoxicity of NMPs. The aim of this study was therefore, to compare the current regulatory immunotoxicity testing requirements with the accumulating knowledge on immunotoxic effects of NMPs in order to identify potential gaps in the safety assessment. This comparison showed that immunotoxic effects, such as complement activation-related pseudoallergy, myelosuppression, inflammasome

  6. Development of fracture toughness test method for nuclear grade graphite

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C. H.; Lee, J. S.; Cho, H. C.; Kim, D. J.; Lee, D. J. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-02-15

    Because of its high strength and stability at very high temperature, as well as very low thermal neutron absorption cross-section, graphite has been widely used as a structural material in Gas Cooled Reactors (GCR). Recently, many countries are developing the Very High Temperature gas cooled Reactor (VHTR) because of the potentials of hydrogen production, as well as its safety and viable economics. In VHTR, helium gas serves as the primary coolant. Graphite will be used as a reflector, moderator and core structural materials. The life time of graphite is determined from dimensional changes due to neutron irradiation, which closely relates to the changes of crystal structure. The changes of both lattice parameter and crystallite size can be easily measured by X-ray diffraction method. However, due to high cost and long time of neutron irradiation test, ion irradiation test is being performed instead in KAERI. Therefore, it is essential to develop the technique for measurement of ion irradiation damage of nuclear graphite. Fracture toughness of nuclear grade graphite is one of the key properties in the design and development of VHTR. It is important not only to evaluate the various properties of candidate graphite but also to assess the integrity of nuclear grade graphite during operation. Although fracture toughness tests on graphite have been performed in many laboratories, there have been wide variations in values of the calculated fracture toughness, due to the differences in the geometry of specimens and test conditions. Hence, standard test method for nuclear graphite is required to obtain the reliable fracture toughness values. Crack growth behavior of nuclear grade graphite shows rising R-curve which means the increase in crack growth resistance as the crack length increases. Crack bridging and microcracking have been proposed to be the dominant mechanisms of rising R-curve behavior. In this paper, the technique to measure the changes of crystallite size and

  7. Comparative Analysis of Hydrogen Production Methods with Nuclear Reactors

    International Nuclear Information System (INIS)

    Morozov, Andrey

    2008-01-01

    Hydrogen is highly effective and ecologically clean fuel. It can be produced by a variety of methods. Presently the most common are through electrolysis of water and through the steam reforming of natural gas. It is evident that the leading method for the future production of hydrogen is nuclear energy. Several types of reactors are being considered for hydrogen production, and several methods exist to produce hydrogen, including thermochemical cycles and high-temperature electrolysis. In the article the comparative analysis of various hydrogen production methods is submitted. It is considered the possibility of hydrogen production with the nuclear reactors and is proposed implementation of research program in this field at the IPPE sodium-potassium eutectic cooling high temperature experimental facility (VTS rig). (authors)

  8. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  9. Chemical methods for peptide and protein production.

    Science.gov (United States)

    Chandrudu, Saranya; Simerska, Pavla; Toth, Istvan

    2013-04-12

    Since the invention of solid phase synthetic methods by Merrifield in 1963, the number of research groups focusing on peptide synthesis has grown exponentially. However, the original step-by-step synthesis had limitations: the purity of the final product decreased with the number of coupling steps. After the development of Boc and Fmoc protecting groups, novel amino acid protecting groups and new techniques were introduced to provide high quality and quantity peptide products. Fragment condensation was a popular method for peptide production in the 1980s, but unfortunately the rate of racemization and reaction difficulties proved less than ideal. Kent and co-workers revolutionized peptide coupling by introducing the chemoselective reaction of unprotected peptides, called native chemical ligation. Subsequently, research has focused on the development of novel ligating techniques including the famous click reaction, ligation of peptide hydrazides, and the recently reported α-ketoacid-hydroxylamine ligations with 5-oxaproline. Several companies have been formed all over the world to prepare high quality Good Manufacturing Practice peptide products on a multi-kilogram scale. This review describes the advances in peptide chemistry including the variety of synthetic peptide methods currently available and the broad application of peptides in medicinal chemistry.

  10. Validation of the cleaning and sanitization method for radiopharmaceutical production facilities

    International Nuclear Information System (INIS)

    Robles, Anita; Morote, Mario; Moore, Mariel; Castro, Delcy; Paragulla, Wilson; Novoa, Carlos; Otero, Manuel; Miranda, Jesus; Herrera, Jorge; Gonzales, Luis

    2014-01-01

    A protocol for the cleaning and sanitization method for radiopharmaceutical production facilities has been designed and developed for the inner surface of the hot cells for the production of Sodium Pertechnetate Tc-99m and Sm-153 EDTMP, considering an extreme situation for each hot cell. Cleaning is performed with double-distilled water and sanitation with two disinfectant solutions, 70 % isopropyl alcohol and 3 % hydrogen peroxide in alternate weeks. Microbiological analysis of sanitized surfaces were made after 20 minutes and 48 hours for the hot cell of Tc-99m and 72 hours for the hot cell of EDTMP Sm-153 in 3 consecutive tests by the method of direct contact with plates containing culture medium, made for each sampling point (6 in the first and five in the second). The results showed that the microbial load on surfaces sanitized was below acceptable limits and that the lifetime of cleaning and sanitization is 48 hours for the hot cell of Tc-99m and 72 hours for the one of EDTMP-Sm-153. As a conclusion, the method of cleaning and sanitization is effective to reduce or eliminate microbial contamination therefore, the process is validated. (authors).

  11. Testing Hubbert

    International Nuclear Information System (INIS)

    Brandt, Adam R.

    2007-01-01

    The Hubbert theory of oil depletion, which states that oil production in large regions follows a bell-shaped curve over time, has been cited as a method to predict the future of global oil production. However, the assumptions of the Hubbert method have never been rigorously tested with a large, publicly available data set. In this paper, three assumptions of the modern Hubbert theory are tested using data from 139 oil producing regions. These regions are sub-national (United States state-level, United States regional-level), national, and multi-national (subcontinental and continental) in scale. We test the assumption that oil production follows a bell-shaped curve by generating best-fitting curves for each region using six models and comparing the quality of fit across models. We also test the assumptions that production over time in a region tends to be symmetric, and that production is more bell-shaped in larger regions than in smaller regions

  12. Test elements of direct sums and free products of free Lie algebras

    Indian Academy of Sciences (India)

    Abstract. We give a characterization of test elements of a direct sum of free Lie algebras in terms of test elements of the factors. In addition, we construct certain types of test elements and we prove that in a free product of free Lie algebras, product of the homogeneous test elements of the factors is also a test element.

  13. Test elements of direct sums and free products of free Lie algebras

    Indian Academy of Sciences (India)

    We give a characterization of test elements of a direct sum of free Lie algebras in terms of test elements of the factors. In addition, we construct certain types of test elements and we prove that in a free product of free Lie algebras, product of the homogeneous test elements of the factors is also a test element.

  14. Multipath interference test method for distributed amplifiers

    Science.gov (United States)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  15. TTC- Based Test as an Efficient Method to Determine Antibiofilm Activity of Silver Nanoparticles

    Directory of Open Access Journals (Sweden)

    Chojniak Joanna

    2017-01-01

    Full Text Available Among metal nanoparticles, silver nanoparticles are a widely used in various life sectors such as in biomedical applications, air and water purification, food production, cosmetics, garments and in various household products. There are several methods for production of silver nanoparticles. Generally, silver nanoparticles can be prepared by chemical methods such as chemical reduction and electrochemical techniques, physical methods, and biological methods such as the use of microorganisms. The biological route of synthesis provides a great diversity in choice for its raw materials such as bacteria, algae, fungi and plants. The aim of the study was to evaluate the tetrazolium/formazan test as a method to determine antibiofilm activity of biological synthetized silver nanoparticles. In this study Bacillus subtilis grown on brewery effluent and produced biosurfactant was used for silver nanoparticles (Ag-NPs synthesis. The culture supernatants were used in synthesis of Ag-NPs. The formation of nanoparticles accompanied by colour changes of the used reaction system was confirmed by UV-vis spectroscopy. The bacteria isolated from the biofilm of water supply system were used in the evaluation of the antibiofilm activity of biologically synthetized Ag-NPs. To compare the results the commonly used crystal violet assay (CV for biofilm analysis was applied.

  16. The New Product Watch: Successes and Challenges of Crowdsourcing as a Method of Surveillance.

    Science.gov (United States)

    Nyman, Amy L; Biener, Lois

    2016-01-01

    New smokeless tobacco (eg, snus and dissolvable tobacco products) and nontobacco nicotine products (eg, e-cigarettes) have emerged in recent years amid widespread speculation about locations of test marketing, toxic constituents, and consumer targeting. The New Product Watch was a pilot online monitoring system aimed at filling these information gaps by using a form of crowdsourcing: recruiting volunteers to visit local retailers and report their findings. With very little funding, the New Product Watch gathered county-specific data on new product availability in 19 states as well as trend data on product marketing and demand, and completed 2 rounds of product purchases and subsequent toxic constituent analyses. Data were collected over a 2-year period, between 2009 and 2011. Despite the successes, we found that this small-scale, volunteer effort was not a sustainable method for ensuring continuous, systematic surveillance of new product availability, marketing, and toxicity.

  17. 46 CFR 164.023-13 - Production tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... Constant Rate of Traverse tensile testing machine, capable of initial clamp separation of ten inches and a... production testing on a lot must meet the following criteria for the lot to be shipped as Coast Guard... the acceptance testing values but not less than the performance minimums. (2) Length/weight values...

  18. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  19. The theory and method of two-well field test for in-situ leaching uranium

    International Nuclear Information System (INIS)

    Yao Yixuan; Huo Jiandang; Xiang Qiulin; Tang Baobin

    2007-01-01

    Because leaching area in field test for in-situ leaching uranium is not accounted exactly, the reliability of obtaining parameters by calculating can not be ensured, and the whole test needs a long time and great investment. In two-well field test, lixiviant is injected from one well, pregnant solution is pumped out from the other, flow rate of the production well is more than that of the injection well, and uranium is not recoveried. In the case of keeping invariable ratio of pumping capacity to injecting capacity during the testing process, leaching area is not variable, can be exactly calculated. The full field test needs six months to one year. Two-well test is a scientific, rapid, minimal spending field test method, and is widely used in Commonwealth of Independent States. (authors)

  20. Comparison of three different methods to detect the production of β-lactamase enzyme by staphylococci

    OpenAIRE

    Jagad, Beena P.; Vakanee, Amit

    2017-01-01

    Production β-lactamase enzyme is the most common and important mode of exhibiting resistance to β-lactam antibiotics. Manifestation of this enzyme is difficult to demonstrate in routine antibiotic sensitivity testing. Sensitivity to penicillin is not sufficient to indicate whether this antibiotic should be used clinically and main factor compromising the clinical efficacy of these drugs is the production of β-lactamase enzyme. Only feasible method for determination of β-lactam resistance is t...

  1. Development of dissolution test method for a telmisartan/amlodipine besylate combination using synchronous derivative spectrofluorimetry

    Directory of Open Access Journals (Sweden)

    Panikumar Durga Anumolu

    2014-04-01

    Full Text Available The dissolution process is considered an important in vitro tool to evaluate product quality and drug release behavior. Single dissolution methods for the analysis of combined dosage forms are preferred to simplify quality control testing. The objective of the present work was to develop and validate a single dissolution test for a telmisartan (TEL and amlodipine besylate (AML combined tablet dosage form. The sink conditions, stability and specificity of both drugs in different dissolution media were tested to choose a discriminatory dissolution method, which uses an USP type-II apparatus with a paddle rotating at 75 rpm, with 900 mL of simulated gastric fluid (SGF without enzymes as the dissolution medium. This dissolution methodology provided good dissolution profiles for both TEL and AML and was able to discriminate changes in the composition and manufacturing process. To quantify both drugs simultaneously, a synchronous first derivative spectrofluorimetric method was developed and validated. Drug release was analyzed by a fluorimetric method at 458 nm and 675 nm for AML and TEL, respectively. The dissolution method was validated as per ICH guidance.

  2. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  3. Methods and materials for production of terpenoids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention provide novel methods for production of terpenoids. The methods take advantage of combinations of enzymes, which are not present in nature. Thus the methods involves use of host organisms expressing a diTPS of class II, diTPS of class I, and one or more CYPs....

  4. 16 CFR 1513.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS..., gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the large end of the... Figure 2 of this part into the portion of the boundary to be tested, with the plane of the template in...

  5. 46 CFR 160.077-23 - Production tests and inspections.

    Science.gov (United States)

    2010-10-01

    ... fixed anchor, or (C) a tensile test machine that is capable of holding a given tension. The assembly... testing of each incoming lot of inflation chamber material before using that lot in production; (iii) Have... inspector must perform or supervise testing and inspection of at least one PFD lot in each five lots...

  6. AmO2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO2 Production

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Kevin John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bland, Galey Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fulwyler, James Brent [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garduno, Katherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Keller, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Klundt, Dylan James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lujan, Elmer J. W [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mark, Zoe Francoise Elise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mathew, Kattathu Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ortega, Laura Claire [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ottenfeld, Chelsea Faith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Porterfield, Donivan R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rearick, Michael Sean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rim, Jung Ho [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schake, Ann Rene [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schappert, Michael Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stanley, Floyd E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Thomas, Mariam R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wylie, Ernest Miller II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Xu, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-08

    Americium oxide samples will be measured for various analytes to support AmO2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO2 reference materials currently available for requested analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO2 production operations.

  7. DPRK's 4"t"h Nuclear Test and its Tritium Production

    International Nuclear Information System (INIS)

    Kim, Min Soo; Lee, Sang Joon; Chang, Sun Young

    2016-01-01

    On January 6, 2016 at 10:30am, the artificial earthquake in the DPRK was detected by multiple international seismic organizations. After 2 hours, the DPRK announced on state TV that 'The first H-bomb test was successfully conducted in the DPRK at 10:00 am on Wednesday, Juche 105(2016), pursuant to the strategic determination of the ruling communist party.' There has been a doubt about the real nature of the DPRK's 4th nuclear test, since 2 months have been passed after its nuclear test. To analyze the nature of the DPRK's nuclear test, it is necessary to check possible options for production of essential materials. The pathways to produce nuclear fusion material (tritium) and to have a relatively high possibility for the DPRK are described in this article. Tritium is key material for H-bomb. And there are two options for the DPRK which are 1) production and 2) illicit trafficking. And this study is focused on production possibility of DPRK. Determination of the nature of DPRK's nuclear test is very hard issue

  8. Development of redesign method of production system based on QFD

    Science.gov (United States)

    Kondoh, Shinsuke; Umeda, Yasusi; Togawa, Hisashi

    In order to catch up with rapidly changing market environment, rapid and flexible redesign of production system is quite important. For effective and rapid redesign of production system, a redesign support system is eagerly needed. To this end, this paper proposes a redesign method of production system based on Quality Function Deployment (QFD). This method represents a designer's intention in the form of QFD, collects experts' knowledge as “Production Method (PM) modules,” and formulates redesign guidelines as seven redesign operations so as to support a designer to find out improvement ideas in a systematical manner. This paper also illustrates a redesign support tool of a production system we have developed based on this method, and demonstrates its feasibility with a practical example of a production system of a contact probe. A result from this example shows that comparable cost reduction to those of veteran designers can be achieved by a novice designer. From this result, we conclude our redesign method is effective and feasible for supporting redesign of a production system.

  9. Transient productivity index for numerical well test simulations

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, G.; Ding, D.Y.; Ene, A. [Institut Francais du Petrole, Pau (France)] [and others

    1997-08-01

    The most difficult aspect of numerical simulation of well tests is the treatment of the Bottom Hole Flowing (BHF) Pressure. In full field simulations, this pressure is derived from the Well-block Pressure (WBP) using a numerical productivity index which accounts for the grid size and permeability, and for the well completion. This productivity index is calculated assuming a pseudo-steady state flow regime in the vicinity of the well and is therefore constant during the well production period. Such a pseudo-steady state assumption is no longer valid for the early time of a well test simulation as long as the pressure perturbation has not reached several grid-blocks around the well. This paper offers two different solutions to this problem: (1) The first one is based on the derivation of a Numerical Transient Productivity Index (NTPI) to be applied to Cartesian grids; (2) The second one is based on the use of a Corrected Transmissibility and Accumulation Term (CTAT) in the flow equation. The representation of the pressure behavior given by both solutions is far more accurate than the conventional one as shown by several validation examples which are presented in the following pages.

  10. Approximate tensor-product preconditioners for very high order discontinuous Galerkin methods

    Science.gov (United States)

    Pazner, Will; Persson, Per-Olof

    2018-02-01

    In this paper, we develop a new tensor-product based preconditioner for discontinuous Galerkin methods with polynomial degrees higher than those typically employed. This preconditioner uses an automatic, purely algebraic method to approximate the exact block Jacobi preconditioner by Kronecker products of several small, one-dimensional matrices. Traditional matrix-based preconditioners require O (p2d) storage and O (p3d) computational work, where p is the degree of basis polynomials used, and d is the spatial dimension. Our SVD-based tensor-product preconditioner requires O (p d + 1) storage, O (p d + 1) work in two spatial dimensions, and O (p d + 2) work in three spatial dimensions. Combined with a matrix-free Newton-Krylov solver, these preconditioners allow for the solution of DG systems in linear time in p per degree of freedom in 2D, and reduce the computational complexity from O (p9) to O (p5) in 3D. Numerical results are shown in 2D and 3D for the advection, Euler, and Navier-Stokes equations, using polynomials of degree up to p = 30. For many test cases, the preconditioner results in similar iteration counts when compared with the exact block Jacobi preconditioner, and performance is significantly improved for high polynomial degrees p.

  11. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  12. ADM guidance-Ceramics: Fracture toughness testing and method selection.

    Science.gov (United States)

    Cesar, Paulo Francisco; Della Bona, Alvaro; Scherrer, Susanne S; Tholey, Michael; van Noort, Richard; Vichi, Alessandro; Kelly, Robert; Lohbauer, Ulrich

    2017-06-01

    The objective is within the scope of the Academy of Dental Materials Guidance Project, which is to provide dental materials researchers with a critical analysis of fracture toughness (FT) tests such that the assessment of the FT of dental ceramics is conducted in a reliable, repeatable and reproducible way. Fracture mechanics theory and FT methodologies were critically reviewed to introduce basic fracture principles and determine the main advantages and disadvantages of existing FT methods from the standpoint of the dental researcher. The recommended methods for FT determination of dental ceramics were the Single Edge "V" Notch Beam (SEVNB), Single Edge Precracked Beam (SEPB), Chevron Notch Beam (CNB), and Surface Crack in Flexure (SCF). SEVNB's main advantage is the ease of producing the notch via a cutting disk, SEPB allows for production of an atomically sharp crack generated by a specific precracking device, CNB is technically difficult, but based on solid fracture mechanics solutions, and SCF involves fracture from a clinically sized precrack. The IF test should be avoided due to heavy criticism that has arisen in the engineering field regarding the empirical nature of the calculations used for FT determination. Dental researchers interested in FT measurement of dental ceramics should start with a broad review of fracture mechanics theory to understand the underlying principles involved in fast fracture of ceramics. The choice of FT methodology should be based on the pros and cons of each test, as described in this literature review. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Chemical Methods for Peptide and Protein Production

    Directory of Open Access Journals (Sweden)

    Istvan Toth

    2013-04-01

    Full Text Available Since the invention of solid phase synthetic methods by Merrifield in 1963, the number of research groups focusing on peptide synthesis has grown exponentially. However, the original step-by-step synthesis had limitations: the purity of the final product decreased with the number of coupling steps. After the development of Boc and Fmoc protecting groups, novel amino acid protecting groups and new techniques were introduced to provide high quality and quantity peptide products. Fragment condensation was a popular method for peptide production in the 1980s, but unfortunately the rate of racemization and reaction difficulties proved less than ideal. Kent and co-workers revolutionized peptide coupling by introducing the chemoselective reaction of unprotected peptides, called native chemical ligation. Subsequently, research has focused on the development of novel ligating techniques including the famous click reaction, ligation of peptide hydrazides, and the recently reported a-ketoacid-hydroxylamine ligations with 5-oxaproline. Several companies have been formed all over the world to prepare high quality Good Manufacturing Practice peptide products on a multi-kilogram scale. This review describes the advances in peptide chemistry including the variety of synthetic peptide methods currently available and the broad application of peptides in medicinal chemistry.

  14. Testing isotopic labeling with [¹³C₆]glucose as a method of advanced glycation sites identification.

    Science.gov (United States)

    Kielmas, Martyna; Kijewska, Monika; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2012-12-01

    The Maillard reaction occurring between reducing sugars and reactive amino groups of biomolecules leads to the formation of a heterogeneous mixture of compounds: early, intermediate, and advanced glycation end products (AGEs). These compounds could be markers of certain diseases and of the premature aging process. Detection of Amadori products can be performed by various methods, including MS/MS techniques and affinity chromatography on immobilized boronic acid. However, the diversity of the structures of AGEs makes detection of these compounds more difficult. The aim of this study was to test a new method of AGE identification based on isotope (13)C labeling. The model protein (hen egg lysozyme) was modified with an equimolar mixture of [(12)C(6)]glucose and [(13)C(6)]glucose and then subjected to reduction of the disulfide bridges followed by tryptic hydrolysis. The digest obtained was analyzed by LC-MS. The glycation products were identified on the basis of characteristic isotopic patterns resulting from the use of isotopically labeled glucose. This method allowed identification of 38 early Maillard reaction products and five different structures of the end glycation products. This isotopic labeling technique combined with LC-MS is a sensitive method for identification of advanced glycation end products even if their chemical structure is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Test of a mosquito eggshell isolation method and subsampling procedure.

    Science.gov (United States)

    Turner, P A; Streever, W J

    1997-03-01

    Production of Aedes vigilax, the common salt-marsh mosquito, can be assessed by determining eggshell densities found in soil. In this study, 14 field-collected eggshell samples were used to test a subsampling technique and compare eggshell counts obtained with a flotation method to those obtained by direct examination of sediment (DES). Relative precision of the subsampling technique was assessed by determining the minimum number of subsamples required to estimate the true mean and confidence interval of a sample at a predetermined confidence level. A regression line was fitted to cube-root transformed eggshell counts obtained from flotation and DES and found to be significant (P eggshells present. Eggshells obtained with the flotation method can be used to predict those from DES using the following equation: DES count = [1.386 x (flotation count)0.33 - 0.01]3.

  16. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  18. Some absolutely effective product methods

    Directory of Open Access Journals (Sweden)

    H. P. Dikshit

    1992-01-01

    Full Text Available It is proved that the product method A(C,1, where (C,1 is the Cesàro arithmetic mean matrix, is totally effective under certain conditions concerning the matrix A. This general result is applied to study absolute Nörlund summability of Fourier series and other related series.

  19. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  20. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  1. Software Testing and its Relationship to the Context of the Product

    Directory of Open Access Journals (Sweden)

    Giordano Soares

    2011-12-01

    Full Text Available Test equipment today have to deal with the growing complexity of the systems under test, while the schedules, budgets and team sizes are not scaled in the same relationship. In addition, the entire test plan cannot be automate and due to time and budget constraints, only a small fraction of all use cases can be covered in the manual tests. For this, the testers must be familiar with the context of the product under test, to design a test plan effective. This article describes the advantages that lead the fact that the testers know the domain of the software product, especially in relation to managing the complexity and problems of selection and prioritization of tests

  2. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods

    Directory of Open Access Journals (Sweden)

    Alistair Currie

    2011-11-01

    Full Text Available In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.

  3. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods.

    Science.gov (United States)

    Dozier, Samantha; Brown, Jeffrey; Currie, Alistair

    2011-11-29

    In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.

  4. Method for the production of primary amines

    NARCIS (Netherlands)

    Baldenius, Kai-Uwe; Ditrich, Klaus; Breurer, Michael; Navickas, Vaidotas; Janssen, Dick; Crismaru, Ciprian; Bartsch, Sebastian

    2014-01-01

    The present invention relates to a novel enzymatically catalyzed method for the production of aliphatic primary amines, which method comprises the enzymatic oxidation of a primary aliphatic alcohol catalyzed by an alcohol dehydrogenase, amination of the resulting oxocompound catalyzed by a

  5. Comparative product testing of children's restraint systems, with inclusion of side-collision tests

    Energy Technology Data Exchange (ETDEWEB)

    Goerlitz, H. [Stiftung Warentest, Berlin (Germany); Noeske, V. [DEKRA Dresden (Germany)

    2001-07-01

    Stiftung Warentest has conducted comparative product testing for Group 0.. III child car seats to evaluate accident protection, handling, comfort of the seats, and safety against faulty use. The tests that were conducted were intended to provide assessment of product quality. Owing to great reader interest, tests conducted on child car seats have become well established for a considerable number of years now. They enjoy esteemed status, for example, in our magazine test. Stiftung Warentest conducted its first tests on children's restraint system many years ago: in May of 1968. The great interest in this topic, as evidenced by widespread feedback from readers, justifies the high costs occasioned by the dynamic testing of children's restraint systems. The popularity of this topic leads to greater sales of the particular issues of the magazine test - which carries no advertising - and at least compensates for most of the added costs necessary for dynamic collision testing. It is not generally well known that Stiftung Warentest covers approximately 90% of its budget from the sales of its two magazines test and Finanztest, and of its other special publications. The annual subsidy by the German government is relatively small. The national subsidy is intended to compensate for the loss of revenue from the exclusion of advertising. (orig.)

  6. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  7. Fluorescent penetration crack testing method

    International Nuclear Information System (INIS)

    Roth, A.

    1979-01-01

    The same cleaning, penetration, washing, development and evaluation agents are used in this method as for known methods. In order to accelerate or shorten the testing, the drying process is performed only to optical dryness of the material surface by blowing on it with pressurized air, the development by simple pressing into or dusting of the material with the developer and the temperature of the washing water is selected within room temperature range. (RW) [de

  8. Improved sensitivity testing of explosives using transformed Up-Down methods

    International Nuclear Information System (INIS)

    Brown, Geoffrey W

    2014-01-01

    Sensitivity tests provide data that help establish guidelines for the safe handling of explosives. Any sensitivity test is based on assumptions to simplify the method or reduce the number of individual sample evaluations. Two common assumptions that are not typically checked after testing are 1) explosive response follows a normal distribution as a function of the applied stimulus levels and 2) the chosen test level spacing is close to the standard deviation of the explosive response function (for Bruceton Up-Down testing for example). These assumptions and other limitations of traditional explosive sensitivity testing can be addressed using Transformed Up-Down (TUD) test methods. TUD methods have been developed extensively for psychometric testing over the past 50 years and generally use multiple tests at a given level to determine how to adjust the applied stimulus. In the context of explosive sensitivity we can use TUD methods that concentrate testing around useful probability levels. Here, these methods are explained and compared to Bruceton Up-Down testing using computer simulation. The results show that the TUD methods are more useful for many cases but that they do require more tests as a consequence. For non-normal distributions, however, the TUD methods may be the only accurate assessment method.

  9. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  10. Comparison of methods for estimating carbon in harvested wood products

    International Nuclear Information System (INIS)

    Claudia Dias, Ana; Louro, Margarida; Arroja, Luis; Capela, Isabel

    2009-01-01

    There is a great diversity of methods for estimating carbon storage in harvested wood products (HWP) and, therefore, it is extremely important to agree internationally on the methods to be used in national greenhouse gas inventories. This study compares three methods for estimating carbon accumulation in HWP: the method suggested by Winjum et al. (Winjum method), the tier 2 method proposed by the IPCC Good Practice Guidance for Land Use, Land-Use Change and Forestry (GPG LULUCF) (GPG tier 2 method) and a method consistent with GPG LULUCF tier 3 methods (GPG tier 3 method). Carbon accumulation in HWP was estimated for Portugal under three accounting approaches: stock-change, production and atmospheric-flow. The uncertainty in the estimates was also evaluated using Monte Carlo simulation. The estimates of carbon accumulation in HWP obtained with the Winjum method differed substantially from the estimates obtained with the other methods, because this method tends to overestimate carbon accumulation with the stock-change and the production approaches and tends to underestimate carbon accumulation with the atmospheric-flow approach. The estimates of carbon accumulation provided by the GPG methods were similar, but the GPG tier 3 method reported the lowest uncertainties. For the GPG methods, the atmospheric-flow approach produced the largest estimates of carbon accumulation, followed by the production approach and the stock-change approach, by this order. A sensitivity analysis showed that using the ''best'' available data on production and trade of HWP produces larger estimates of carbon accumulation than using data from the Food and Agriculture Organization. (author)

  11. Validation of Land Cover Products Using Reliability Evaluation Methods

    Directory of Open Access Journals (Sweden)

    Wenzhong Shi

    2015-06-01

    Full Text Available Validation of land cover products is a fundamental task prior to data applications. Current validation schemes and methods are, however, suited only for assessing classification accuracy and disregard the reliability of land cover products. The reliability evaluation of land cover products should be undertaken to provide reliable land cover information. In addition, the lack of high-quality reference data often constrains validation and affects the reliability results of land cover products. This study proposes a validation schema to evaluate the reliability of land cover products, including two methods, namely, result reliability evaluation and process reliability evaluation. Result reliability evaluation computes the reliability of land cover products using seven reliability indicators. Process reliability evaluation analyzes the reliability propagation in the data production process to obtain the reliability of land cover products. Fuzzy fault tree analysis is introduced and improved in the reliability analysis of a data production process. Research results show that the proposed reliability evaluation scheme is reasonable and can be applied to validate land cover products. Through the analysis of the seven indicators of result reliability evaluation, more information on land cover can be obtained for strategic decision-making and planning, compared with traditional accuracy assessment methods. Process reliability evaluation without the need for reference data can facilitate the validation and reflect the change trends of reliabilities to some extent.

  12. Method for anaerobic fermentation and biogas production

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a method for biomass processing, anaerobic fermentation of the processed biomass, and the production biogas. In particular, the invention relates to a system and method for generating biogas from anaerobic fermentation of processed organic material that comprises...

  13. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  14. Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Directory of Open Access Journals (Sweden)

    Ujhelyi Gabriella

    2012-01-01

    Full Text Available Abstract Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i hybridisation and ligation of specific probes, ii amplification of the ligated probes and iii detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands. Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the

  15. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 1. Method development and validation.

    Science.gov (United States)

    Damgaard, Rasmus; Rasmussen, Mats; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton

    2013-01-01

    In Part 1 of this three-part research series, a leak test performed using high-voltage leak detection (HVLD) technology, also referred to as an electrical conductivity and capacitance leak test, was developed and validated for container-closure integrity verification of a small-volume laminate plastic bag containing an aqueous solution for injection. The sterile parenteral product is the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®, by Novo Nordisk A/S, Bagsværd, Denmark). The aseptically filled and sealed package is designed to preserve product sterility through expiry. Method development and validation work incorporated positive control packages with a single hole laser-drilled through the laminate film of each bag. A unique HVLD method characterized by specific high-voltage and potentiometer set points was established for testing bags positioned in each of three possible orientations as they are conveyed through the instrument's test zone in each of two possible directions-resulting in a total of six different test method options. Validation study results successfully demonstrated the ability of all six methods to accurately and reliably detect those packages with laser-drilled holes from 2.5-11.2 μm in nominal diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product physico-chemical stability. In this Part 1 of a three-part research series, a leak test method based on electrical conductivity and capacitance, called high voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with an insulin pharmaceutical solution for human injection by Novo Nordisk A/S (Bagsværd, Denmark). To perform the test, the package is electrically grounded while being conveyed past an electrode linked to a high-voltage, low-amperage transformer. The instrument measures the current that passes

  16. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have...

  17. Synthesis H-Zeolite catalyst by impregnation KI/KIO3 and performance test catalyst for biodiesel production

    Science.gov (United States)

    Widayat, W.; Rizky Wicaksono, Adit; Hakim Firdaus, Lukman; Okvitarini, Ndaru

    2016-02-01

    The objective of this research is to produce H-catalyst catalyst that was impregnated with KI/KIO3. The catalyst was analyzed about surface area, X-Ray Diffraction (XRD) and performance test of catalyst for biodiesel production. An H-Zeolite catalyst was synthesized from natural zeolite with chemical treatment processing, impregnation KI/KIO3 and physical treatment. The results shows that the surface area of the catalyst by 27.236 m2/g at a concentration of 5% KI. XRD analysis shows peak 2-θ at 23.627o indicating that KI was impregnated on H-zeolite catalyst. The catalyst was tested in production of biodiesel using palm oil with conventional methods for 3 hour at temperature of 70-80 oC. The result for conversion Fatty Acid Methyl Ester (FAME) reached maximum value on 87.91% under production process using catalyst 5% KIO3-H zeolite.

  18. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421

  19. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation.

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session.

  20. Chemical Characterization and Reactivity Testing of Fuel-Oxidizer Reaction Product (Test Report)

    Science.gov (United States)

    1996-01-01

    The product of incomplete reaction of monomethylhydrazine (MMH) and nitrogen tetroxide (NTO) propellants, or fuel-oxidizer reaction product (FORP), has been hypothesized as a contributory cause of an anomaly which occurred in the chamber pressure (PC) transducer tube on the Reaction Control Subsystem (RCS) aft thruster 467 on flight STS-51. A small hole was found in the titanium-alloy PC tube at the first bend below the pressure transducer. It was surmised that the hole may have been caused by heat and pressure resulting from ignition of FORP. The NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) was requested to define the chemical characteristics of FORP, characterize its reactivity, and simulate the events in a controlled environment which may have lead to the Pc-tube failure. Samples of FORP were obtained from the gas-phase reaction of MMH with NTO under laboratory conditions, the pulsed firings of RCS thrusters with modified PC tubes using varied oxidizer or fuel lead times, and the nominal RCS thruster firings at WSTF and Kaiser-Marquardt. Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), ion chromatography (IC), inductively coupled plasma (ICP) spectrometry, thermogravimetric analysis (TGA) coupled to FTIR (TGA/FTIR), and mechanical impact testing were used to qualitatively and quantitatively characterize the chemical, thermal, and ignition properties of FORP. These studies showed that the composition of FORP is variable but falls within a limited range of compositions that depends on the fuel loxidizer ratio at the time of formation, composition of the post-formation atmosphere (reducing or oxidizing), and reaction or postreaction temperature. A typical composition contains methylhydrazinium nitrate (MMHN), ammonium nitrate (AN), methylammonium nitrate (MAN), and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. The thermal decomposition

  1. Simplified method of ''push-pull'' test data analysis for determining in situ reaction rate coefficients

    International Nuclear Information System (INIS)

    Haggerty, R.; Schroth, M.H.; Istok, J.D.

    1998-01-01

    The single-well, ''''push-pull'''' test method is useful for obtaining information on a wide variety of aquifer physical, chemical, and microbiological characteristics. A push-pull test consists of the pulse-type injection of a prepared test solution into a single monitoring well followed by the extraction of the test solution/ground water mixture from the same well. The test solution contains a conservative tracer and one or more reactants selected to investigate a particular process. During the extraction phase, the concentrations of tracer, reactants, and possible reaction products are measured to obtain breakthrough curves for all solutes. This paper presents a simplified method of data analysis that can be used to estimate a first-order reaction rate coefficient from these breakthrough curves. Rate coefficients are obtained by fitting a regression line to a plot of normalized concentrations versus elapsed time, requiring no knowledge of aquifer porosity, dispersivity, or hydraulic conductivity. A semi-analytical solution to the advective-dispersion equation is derived and used in a sensitivity analysis to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a homogeneous, confined aquifer with a fully-penetrating injection/extraction well and varying porosity, dispersivity, test duration, and reaction rate. A numerical flow and transport code (SUTRA) is used to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a heterogeneous, unconfined aquifer with a partially penetrating well. In all cases the simplified method provides accurate estimates of reaction rate coefficients; estimation errors ranged from 0.1 to 8.9% with most errors less than 5%

  2. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Production and test of the LHCf microstrip silicon system

    International Nuclear Information System (INIS)

    Bonechi, L.; Adriani, O.; Bongi, M.; Castellini, G.; D'Alessandro, R.; Faus, A.; Haguenauer, M.; Itow, Y.; Kasahara, K.; Macina, D.; Mase, T.; Masuda, K.; Matsubara, Y.; Matsumoto, H.; Menjo, H.; Mizuishi, M.; Muraki, Y.; Papini, P.; Perrot, A.L.; Ricciarini, S.

    2008-01-01

    After a preliminary installation test, successfully performed in 2007, both the detectors of the LHCf experiment are now ready to be installed at the CERN LHC accelerator for the first physics run. A beam test at SPS in September 2007 allowed to verify the performance of the apparata. Production and test of the silicon tracker developed for one of them are shortly discussed in this work.

  4. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  5. Identification of irradiated pasteurized egg products: a combined method to use in routine control

    International Nuclear Information System (INIS)

    Helle, N.; Schulzki, G.; Linke, B.; Spiegelberg, A.; Boegl, K.W.; Schreiber, G.A.; Grabowski, H.U. v.; Pfordt, J.; Mauermann, U.; Juelicher, S.; Bischoff, C.; Vater, N.; Heitmann, M.

    1993-01-01

    Pasteurized egg products (whole egg, egg yolk and egg white) were tested for irradiation treatment in the German food control laboratories in Oldenburg/Niedersachsen and Kassel/Hessen as well as in the food irradiation laboratory of the German federal health office. Gas chromatographic/mass spectrometric measurements on the fat components of egg-products showed clearly whether the product had been irradiated or not. While in unirradiated samples no traces of special hydrocarbons (according to the fatty acid composition of egg) and no traces of the irradiation-specific compound 2-Dodecyl-cyclobutanone were found, irradiated control samples as well as products of two belgian suppliers contained these substances. Additionally, regarding the rather high time consumption of gas chromatography, electron spin resonance (ESR)-measurements were carried out on the packaging material of egg products. Irradiated packaging material (cellulose) could be easily detected by the appearance of a signal pair in the ESR spectrum (cellulose radical). ESR measurements are very fast and easy to perform so that this method can be used for screening. Microbiological investigations showed remarkably reduced total numbers of microorganisms for some irradiated samples, but the microbiological status is influenced by other factors like storage-time and -temperature, so that microbiological tests can not be used successfully for screening on irradiation treatment [de

  6. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four......The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  7. How to assess the mutagenic potential of cosmetic products without animal tests?

    Science.gov (United States)

    Speit, Günter

    2009-08-01

    Animal experiments (in vivo tests) currently play a key role in genotoxicity testing. Results from in vivo tests are, in many cases, decisive for the assessment of a mutagenic potential of a test compound. The Seventh Amendment to the European Cosmetics Directive will, however, ban the European marketing of cosmetic/personal care products that contain ingredients that have been tested in animal experiments. If genotoxicity testing is solely based on the currently established in vitro tests, the attrition rate for chemicals used in cosmetic products will greatly increase due to irrelevant positive in vitro test results. There is urgent need for new and/or improved in vitro genotoxicity tests and for modified test strategies. Test strategies should consider all available information on chemistry of the test substance/the chemical class (e.g. SAR, metabolic activation and dermal adsorption). Test protocols for in vitro genotoxicity tests should be sensitive and robust enough to ensure that negative results can be accepted with confidence. It should be excluded that positive in vitro test results are due to high cytotoxicity or secondary genotoxic effects which may be thresholded and/or only occur under in vitro test conditions. Consequently, further research is needed to establish the nature of thresholds in in vitro assays and to determine the potential for incorporation of mode of action data into future risk assessments. New/improved tests have to be established and validated, considering the use of (metabolically competent) primary (skin) cells, 3D skin models and cells with defined capacity for metabolic activation (e.g. genetically engineered cell lines). The sensitivity and specificity of new and improved genotoxicity tests has to be determined by testing a battery of genotoxic and non-genotoxic chemicals. New or adapted international guidelines will be needed for these tests. The establishment of such a new genotoxicity testing strategy will take time and the

  8. 40 CFR Appendix A to Part 63 - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods A Appendix A to Part 63... to Part 63—Test Methods Method 301—Field Validation of Pollutant Measurement Methods from Various Waste Media 1. Applicability and principle 1.1Applicability. This method, as specified in the applicable...

  9. The influence of socio-cultural background and product value in usability testing.

    Science.gov (United States)

    Sonderegger, Andreas; Sauer, Juergen

    2013-05-01

    This article examines the influence of socio-cultural background and product value on different outcomes of usability tests. A study was conducted in two different socio-cultural regions, Switzerland and East Germany, which differed in a number of aspects (e.g. economic power, price sensitivity and culture). Product value (high vs. low) was varied by manipulating the price of the product. Sixty-four test participants were asked to carry out five typical user tasks in the context of coffee machine usage, measuring performance, perceived usability, and emotion. The results showed that in Switzerland, high-value products were rated higher in usability than low-value products whereas in East Germany, high-value products were evaluated lower in usability. A similar interaction effect of socio-cultural background and product value was observed for user emotion. Implications are that the outcomes of usability tests do not allow for a simple transfer across cultures and that the mediating influence of perceived product value needs to be taken into consideration. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. Shelf life prediction of canned fried-rice using accelerated shelf life testing (ASLT) arrhenius method

    Science.gov (United States)

    Kurniadi, M.; Bintang, R.; Kusumaningrum, A.; Nursiwi, A.; Nurhikmat, A.; Susanto, A.; Angwar, M.; Triwiyono; Frediansyah, A.

    2017-12-01

    Research on shelf-life prediction of canned fried rice using Accelerated Shelf-life Test (ASLT) of Arrhenius model has been conducted. The aim of this research to predict shelf life of canned-fried rice products. Lethality value of 121°C for 15 and 20 minutes and Total Plate count methods are used to determine time and temperatures of sterilization process.Various storage temperatures of ASLT Arrhenius method were 35, 45 and 55°C during 35days. Rancidity is one of the derivation quality of canned fried rice. In this research, sample of canned fried rice is tested using rancidity value (TBA). TBA value was used as parameter which be measured once a week periodically. The use of can for fried rice without any chemical preservative is one of the advantage of the product, additionaly the use of physicalproperties such as temperature and pressure during its process can extend the shelf life and reduce the microbial contamination. The same research has never done before for fried rice as ready to eat meal. The result showed that the optimum conditions of sterilization process were 121°C,15 minutes with total plate count number of 9,3 × 101 CFU/ml. Lethality value of canned fried rice at 121°C,15 minutes was 3.63 minutes. The calculated Shelf-life of canned fried rice using Accelerated Shelf-life Test (ASLT) of Arrhenius method was 10.3 months.

  11. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  12. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Sung Jiun

    2014-01-01

    The V and V method has been utilized for this safety critical software, while SRGM has difficulties because of lack of failure occurrence data on developing phase. For the safety critical software, however, failure data cannot be gathered after installation in real plant when we consider the severe consequence. Therefore, to complement the V and V method, the test-based method need to be developed. Some studies on test-based reliability quantification method for safety critical software have been conducted in nuclear field. These studies provide useful guidance on generating test sets. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values. The other problem is number of tests needed. To satisfy a target reliability with reasonable confidence level, very large number of test sets are required. Development of this number of test sets is a herculean

  13. Method for extracting protein from a fermentation product

    Science.gov (United States)

    Lawton, Jr., John Warren; Bootsma, Jason Alan; Lewis, Stephen Michael

    2014-02-18

    A method of producing bioproducts from a feedstock in a system configured to produce ethanol and distillers grains from a fermentation product is disclosed. A system configured to process feedstock into a fermentation product and bioproducts including ethanol and meal is disclosed. A bioproduct produced from a fermentation product produced from a feedstock in a biorefining system is disclosed.

  14. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  15. Methods to evaluate cytotoxicity and immunosuppression of combustible tobacco product preparations.

    Science.gov (United States)

    Arimilli, Subhashini; Damratoski, Brad E; G L, Prasad

    2015-01-10

    Among other pathophysiological changes, chronic exposure to cigarette smoke causes inflammation and immune suppression, which have been linked to increased susceptibility of smokers to microbial infections and tumor incidence. Ex vivo suppression of receptor-mediated immune responses in human peripheral blood mononuclear cells (PBMCs) treated with smoke constituents is an attractive approach to study mechanisms and evaluate the likely long-term effects of exposure to tobacco products. Here, we optimized methods to perform ex vivo assays using PBMCs stimulated by bacterial lipopolysaccharide, a Toll-like receptor-4 ligand. The effects of whole smoke-conditioned medium (WS-CM), a combustible tobacco product preparation (TPP), and nicotine were investigated on cytokine secretion and target cell killing by PBMCs in the ex vivo assays. We show that secreted cytokines IFN-γ, TNF, IL-10, IL-6, and IL-8 and intracellular cytokines IFN-γ, TNF-α, and MIP-1α were suppressed in WS-CM-exposed PBMCs. The cytolytic function of effector PBMCs, as determined by a K562 target cell killing assay was also reduced by exposure to WS-CM; nicotine was minimally effective in these assays. In summary, we present a set of improved assays to evaluate the effects of TPPs in ex vivo assays, and these methods could be readily adapted for testing other products of interest.

  16. Screening tests for hazard classification of complex waste materials – Selection of methods

    International Nuclear Information System (INIS)

    Weltens, R.; Vanermen, G.; Tirez, K.; Robbens, J.; Deprez, K.; Michiels, L.

    2012-01-01

    In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1–15) of the waste which can be assessed from the hazardous properties of individual identified waste compounds or – if not all compounds are identified – from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different

  17. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  18. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  19. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  20. 26 CFR 1.401(a)(26)-7 - Testing methods.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Testing methods. 1.401(a)(26)-7 Section 1.401(a... (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.401(a)(26)-7 Testing methods... the rules in § 1.401(a)(26)-5. (b) Simplified testing method. A plan is treated as satisfying the...

  1. A surrogate method for comparison analysis of salivary concentrations of Xylitol-containing products

    Directory of Open Access Journals (Sweden)

    Zhou Lingmei

    2008-02-01

    Full Text Available Abstract Background Xylitol chewing gum has been shown to reduce Streptococcus mutans levels and decay. Two studies examined the presence and time course of salivary xylitol concentrations delivered via xylitol-containing pellet gum and compared them to other xylitol-containing products. Methods A within-subjects design was used for both studies. Study 1, adults (N = 15 received three xylitol-containing products (pellet gum (2.6 g, gummy bears (2.6 g, and commercially available stick gum (Koolerz, 3.0 g; Study 2, a second group of adults (N = 15 received three xylitol-containing products (pellet gum, gummy bears, and a 33% xylitol syrup (2.67 g. For both studies subjects consumed one xylitol product per visit with a 7-day washout between each product. A standardized protocol was followed for each product visit. Product order was randomly determined at the initial visit. Saliva samples (0.5 mL to 1.0 mL were collected at baseline and up to 10 time points (~16 min in length after product consumption initiated. Concentration of xylitol in saliva samples was analyzed using high-performance liquid chromatography. Area under the curve (AUC for determining the average xylitol concentration in saliva over the total sampling period was calculated for each product. Results In both studies all three xylitol products (Study 1: pellet gum, gummy bears, and stick gum; Study 2: pellet gum, gummy bears, and syrup had similar time curves with two xylitol concentration peaks during the sampling period. Study 1 had its highest mean peaks at the 4 min sampling point while Study 2 had its highest mean peaks between 13 to 16 minutes. Salivary xylitol levels returned to baseline at about 18 minutes for all forms tested. Additionally, for both studies the total AUC for the xylitol products were similar compared to the pellet gum (Study 1: pellet gum – 51.3 μg.min/mL, gummy bears – 59.6 μg.min/mL, and stick gum – 46.4 μg.min/mL; Study 2: pellet gum – 63.0

  2. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  3. Method for indirect quantification of CH4 production via H2O production using hydrogenotrophic methanogens

    Directory of Open Access Journals (Sweden)

    Ruth-Sophie eTaubner

    2016-04-01

    Full Text Available ydrogenotrophic methanogens are an intriguing group of microorganisms from the domain Archaea. They exhibit extraordinary ecological, biochemical, physiological characteristics colorbox{yellow}{and have a huge biotechnological potential}. Yet, the only possibility to assess the methane (CH$_4$ production potential of hydrogenotrophic methanogens is to apply gas chromatographic quantification of CH$_4$.In order to be able to effectively screen pure cultures of hydrogenotrophic methanogens regarding their CH$_4$ production potential we developed a novel method for indirect quantification of colorbox{yellow}{the} volumetric CH$_4$ production rate by measuring colorbox{yellow}{the} volumetric water production rate. This colorbox{yellow}{ } method was established in serum bottles for cultivation of methanogens in closed batch cultivation mode. Water production was colorbox{yellow}{estimated} by determining the difference in mass increase in an isobaric setting.This novel CH$_4$ quantification method is an accurate and precise analytical technique, colorbox{yellow}{which can be used} to rapidly screen pure cultures of methanogens regarding colorbox{yellow}{their} volumetric CH$_{4}$ evolution rate. colorbox{yellow}{It} is a cost effective alternative colorbox{yellow}{determining} CH$_4$ production of methanogens over CH$_4$ quantification by using gas chromatography, especially if colorbox{yellow}{ } applied as a high throughput quantification method. colorbox{yellow}{Eventually, the} method can be universally applied for quantification of CH$_4$ production from psychrophilic, thermophilic and hyperthermophilic hydrogenotrophic methanogens.

  4. 49 CFR Appendix B to Part 238 - Test Methods and Performance Criteria for the Flammability and Smoke Emission Characteristics of...

    Science.gov (United States)

    2010-10-01

    ... and Products Using an Oxygen Consumption Calorimeter. (x) ASTM E 1537-99, Standard Test Method for... Furniture for Use in Public Occupancies (January, 1991). (b) Definitions. As used in this appendix— Average... specified in the table, and (b) the ASTM E 662-01 smoke generation test procedure. Testing shall be at 50 kW...

  5. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented.

  6. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    International Nuclear Information System (INIS)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented

  7. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  8. Alternative method of inservice hydraulic testing of difficult to test pumps

    International Nuclear Information System (INIS)

    Stockton, N.B.; Shangari, S.

    1994-01-01

    The pump test codes require that system resistance be varied until the independent variable (either the pump flow rate or differential pressure) equals its reference value. Variance from this fixed reference value is not specifically allowed. However, the design of many systems makes it impractical to set the independent variable to an exact value. Over a limited range of pump operation about the fixed reference value, linear interpolation between two points of pump operation can be used to accurately determine degradation at the reference value without repeating reference test conditions. This paper presents an overview of possible alternatives for hydraulic testing of pumps and a detailed discussion of the linear interpolation method. The approximation error associated with linear interpolation is analyzed. Methods to quantify and minimize approximation error are presented

  9. Validation of a liquid chromatographic method for the pharmaceutical quality control of products containing elacridar

    Directory of Open Access Journals (Sweden)

    Emilia Sawicki

    2016-08-01

    Full Text Available Many anticancer drugs have an impaired bioavailability and poor brain penetration because they are substrates to drug efflux pumps such as P-glycoprotein and Breast Cancer Resistance Protein. Elacridar is a strong inhibitor of these two drug efflux pumps and therefore has great potential to improve oral absorption and brain penetration of many anticancer drugs. Currently, a clinical formulation of elacridar is unavailable and therefore the pharmaceutical development of a drug product is highly warranted. This also necessitates the availability of an analytical method for its quality control. A reverse-phase high-performance liquid chromatographic method with ultraviolet detection was developed for the pharmaceutical quality control of products containing elacridar as the active pharmaceutical ingredient. The analytical method was validated for linearity, accuracy, precision, selectivity, carry-over, stability of stock and reference solutions, stability of the final extract, stability-indicating capability and impurity testing. We found that elacridar is unstable in aqueous solutions that are exposed to light because a hydroxylation product of elacridar is formed. Therefore, sample solutions with elacridar must be protected from light.

  10. Production and detection of cold anti-hydrogen atoms A first step towards high precision CPT test

    CERN Document Server

    Variola, A; Bonomi, G; Boutcha, A; Bowe, P; Carraro, C; Cesar, C L; Charlton, M; Doser, Michael; Filippini, V; Fontana, A; Fujiwara, M C; Funakoshi, R; Genova, P; Hangst, J S; Hayano, R S; Jørgensen, L V; Lagomarsino, V; Landua, Rolf; Lindelöf, D; Lodi-Rizzini, E; Macri, M; Madsen, N; Manuzio, G; Montagna, P; Pruys, H S; Regenfus, C; Rotondi, A; Riedler, P; Testera, G; Van der Werf, D P

    2003-01-01

    Observations of anti-hydrogen in small quantities have been reported at CERN and at FermiLab, but these experiments were not suited to spectroscopy experiments. In 2002 the ATHENA collaboration reported the production and detection of very low energy anti-hydrogen atoms produced in cryogenic environment. This is the first major step in the study of antiatom's internal structure and it can lead to a high precision test of the CPT fundamental symmetry. The method of production and detection of cold anti-hydrogen will be introduced. The absolute rate of anti-hydrogen production and the signal to background ratio in the ATHENA experiment will be discussed. (7 refs) .

  11. A/T test system for production line; Seisan line yo A/T test system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-10

    This paper introduces an A/T test system for production line made by Meidensha, Inc. Rates and technology of mounting auto-transmissions (A/T) in recent automobiles are improving year after year. A/T production line testers were fabricated and supplied, including those for European countries. This system has the following features: the system employs low inertia AC motor, and is capable of performing tests in close conditions to actual cars; an insulated gate bipolar transistor (IGBT) inverter was employed to achieve control accuracy improvement and noise reduction; high-velocity transient measurement is possible by using a computer system based on the WindowsNT; a solenoid current slant control was employed to respond to electronically controlled A/T; and noise and vibration shift feeling instrumentation can also be used on option. Number of supply is four sets of front engine/front wheel drive (FF) car A/T testers for overseas countries, and two sets of FF A/T tests for use in Japan. (NEDO)

  12. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... to the Administrator for approval under § 60.8(b) to use a reference method with minor changes in... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  13. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...

  14. New product testing and the utilization of user expertise: Evidence from the Pharmaceutical industry

    DEFF Research Database (Denmark)

    Smed, Marie; Salomo, Søren; Schultz, Carsten

    2012-01-01

    A significant and often neglected obstacle in new product development is the testing and approval process in the late stages of development. The testing process has primarily been observed as an in-house decision process, however, in many industries products undergo extensive testing before marke....... Further, with a dispersed user network a positive effect is observed on the mean to communicate directly as issues occur. The effect of virtual communication is therefore stronger than traditional face-to-face interaction patterns.......A significant and often neglected obstacle in new product development is the testing and approval process in the late stages of development. The testing process has primarily been observed as an in-house decision process, however, in many industries products undergo extensive testing before market...... the knowledge generated and shared by medical sites and Pharmaceutical producers in late stage product development. The results show, that information regarding usage patterns and product related services are more difficult to transfer between user and developer, than issues directly related to the product...

  15. Determination of radiography optimum conditions for complex shape products by simplex planning method

    International Nuclear Information System (INIS)

    Kipnis, M.A.; Korsunskij, G.M.; Mironenko, A.F.

    1984-01-01

    It has been suggested that the optimum regime of radiography should be determined using the method of successive simplex planning, which can be convenient in the cases, when the result of testing can not be presented quantitatively. Besides, in this case there is no necessity in duplication of experiments, as even gross errors are automatically corrected with further simplex motion. A plan and results of experimental determination of the optimum regime of product radiography using the X-ray RUP-120-5-1 apparatus are presented. In the experiments described voltage, current intensity and radiography duration are varied. The quality of X-ray images is evaluated according to conventional ten-point scale, taking into account the quality of each projection. It has been established that application of simplex planning to determine regimes of X-ray radiography of different types of products permits to obtain high-quality roentgenograms with simultaneous decrease in the consumption of photomaterials and considerable decrease in the time of laboratory tests

  16. Nondestructive testing methods for 55-gallon, waste storage drums

    International Nuclear Information System (INIS)

    Ferris, R.H.; Hildebrand, B.P.; Hockey, R.L.; Riechers, D.M.; Spanner, J.C.; Duncan, D.R.

    1993-06-01

    The Westinghouse Hanford Company (WHC) authorized Pacific Northwest Laboratory (PNL) to conduct a feasibility study to identify promising nondestructive testing (NDT) methods for detecting general and localized (both pitting and pinhole) corrosion in the 55-gal drums that are used to store solid waste materials at the Hanford Site. This document presents results obtained during a literature survey, identifies the relevant reference materials that were reviewed, provides a technical description of the methods that were evaluated, describes the laboratory tests that were conducted and their results, identifies the most promising candidate methods along with the rationale for these selections, and includes a work plan for recommended follow-on activities. This report contains a brief overview and technical description for each of the following NDT methods: magnetic testing techniques; eddy current testing; shearography; ultrasonic testing; radiographic computed tomography; thermography; and leak testing with acoustic detection

  17. A practical method for extending the biuret assay to protein determination of corn-based products.

    Science.gov (United States)

    Liu, Zelong; Pan, Junhui

    2017-06-01

    A modified biuret method suitable for protein determination of corn-based products was developed by introducing a combination of an alkaline reagent with sodium dodecyl sulfate (reagent A) and heat treatments. The method was tested on seven corn-based samples. The results showed mostly good agreement (P>0.05) as compared to the Kjeldahl values. The proposed method was found to enhance the accuracy of prediction on zein content using bovine serum albumin as standard. Reagent A and sample treatment were proved to effectively improve protein solubilization for the thermally-dried corn-based products, e.g. corn gluten meal. The absorbance was stable for at least 1-h. Moreover, the whole measurement of protein content only needs 15-20min more than the traditional biuret assay, and can be performed in batches. The findings suggest that the proposed method could be a timesaving alternative for routine protein analyses in corn processing factories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Off-Line Testing of Tribo-Systems for Sheet Metal Forming Production

    DEFF Research Database (Denmark)

    Bay, Niels; Ceron, Ermanno

    2014-01-01

    Off-line testing of new tribo-systems for sheet metal forming production is an important issue, when new, environmentally benign lubricants are to be introduced. To obtain useful results it is, however, vital to ensure similar conditions as in the production process regarding the main tribo...... leading to very high tool/workpiece interface pressure and temperature in the second re-draw. Under such conditions only the best lubricant systems work satisfactory, and the paper shows how the performance of different tribo-systems in production may be predicted by off-line testing combined...

  19. Estimation of graphite dust production in ITER TBM using finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ji-Ho, E-mail: jhkang@kaeri.re.kr [Korea Atomic Energy Research Institute, 989-111, Daekeok-Daero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Kim, Eung Seon [Korea Atomic Energy Research Institute, 989-111, Daekeok-Daero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Ahn, Mu-Young; Lee, Youngmin; Park, Yi-Hyun; Cho, Seungyon [National Fusion Research Institute, 169-148, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of)

    2015-12-15

    Highlights: • Graphite dust production was estimated for the Korean Helium Cooled Ceramic Reflector. • Wear amount was calculated by Archard model using finite element analysis results. • Life time estimation of graphite dust production was done. - Abstract: In this study, an estimation method of graphite dust production in the pebble-bed type reflector region of the Korean Helium Cooled Ceramic Reflector (HCCR) Test Blanket Module (TBM) of the International Thermonuclear Experimental Reactor (ITER) project using Finite Element Method (FEM) was proposed and the total amount of dust production was calculated. A unit-cell model of uniformly arranged pebbles was defined with thermal and mechanical loadings. A commercial FEM program, Abaqus V6.10, was used to model and solve the stress field under multiple contact constraints between pebbles in the unit-cell. Resultant normal contact forces and slip distances on the contact points were applied into the Archard adhesive wear model to calculate the amount of graphite dust. The Finite Element (FE) analysis was repeated at 27 unit-cell locations chosen to form an interpolated dust density function for the entire region of the reflector. The dust production calculation was extended to the life time of the HCCR and the total graphite dust production was estimated to 0.279 g at the end of the life time with the maximum graphite dust density of 0.149 μg/mm{sup 3}. The dust explosion could be a safety issue with the calculated dust density level and it requires that an appropriate maintenance to remove sufficient amount of graphite dust regularly to prevent the possibility of dust explosion.

  20. Estimation of graphite dust production in ITER TBM using finite element method

    International Nuclear Information System (INIS)

    Kang, Ji-Ho; Kim, Eung Seon; Ahn, Mu-Young; Lee, Youngmin; Park, Yi-Hyun; Cho, Seungyon

    2015-01-01

    Highlights: • Graphite dust production was estimated for the Korean Helium Cooled Ceramic Reflector. • Wear amount was calculated by Archard model using finite element analysis results. • Life time estimation of graphite dust production was done. - Abstract: In this study, an estimation method of graphite dust production in the pebble-bed type reflector region of the Korean Helium Cooled Ceramic Reflector (HCCR) Test Blanket Module (TBM) of the International Thermonuclear Experimental Reactor (ITER) project using Finite Element Method (FEM) was proposed and the total amount of dust production was calculated. A unit-cell model of uniformly arranged pebbles was defined with thermal and mechanical loadings. A commercial FEM program, Abaqus V6.10, was used to model and solve the stress field under multiple contact constraints between pebbles in the unit-cell. Resultant normal contact forces and slip distances on the contact points were applied into the Archard adhesive wear model to calculate the amount of graphite dust. The Finite Element (FE) analysis was repeated at 27 unit-cell locations chosen to form an interpolated dust density function for the entire region of the reflector. The dust production calculation was extended to the life time of the HCCR and the total graphite dust production was estimated to 0.279 g at the end of the life time with the maximum graphite dust density of 0.149 μg/mm"3. The dust explosion could be a safety issue with the calculated dust density level and it requires that an appropriate maintenance to remove sufficient amount of graphite dust regularly to prevent the possibility of dust explosion.

  1. Stopping test of iterative methods for solving PDE

    International Nuclear Information System (INIS)

    Wang Bangrong

    1991-01-01

    In order to assure the accuracy of the numerical solution of the iterative method for solving PDE (partial differential equation), the stopping test is very important. If the coefficient matrix of the system of linear algebraic equations is strictly diagonal dominant or irreducible weakly diagonal dominant, the stopping test formulas of the iterative method for solving PDE is proposed. Several numerical examples are given to illustrate the applications of the stopping test formulas

  2. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  3. Use of test results from the percolation leaching test (TS3) in the framework of the Construction Products Directive

    Energy Technology Data Exchange (ETDEWEB)

    Van Zomeren, A.; Dijkstra, J.J. [ECN Environment and Energy Engineering, Petten (Netherlands); Mesman, M.; Spijker, J. [National Institute for Public Health and the Environment RIVM, Bilthoven (Netherlands); Eikelboom, R. [Ministry of Infrastructure and Environment IenM, Den Haag (Netherlands)

    2013-10-15

    The enforcement of the European Construction Products Directive (and the more actual Construction Products Regulation) has led to the development of European harmonised standards for assessment of the emission of 'dangerous substances' from construction materials. According to Basic Working Requirement (BWR) number 3, the emissions from construction products to soil and groundwater should not have an unacceptable impact on the environmental quality over the life cycle of the product. In this paper the technical needs and boundary conditions of leaching tests to obtain meaningful and reliable test results are explained. Although this paper will not go into detail on 'impact assessment' and the resulting development of regulatory criteria, we will show that the technical needs and boundary conditions of a test are to some extent dependent on what type of information is needed by regulators for environmental impact assessment. This short paper focuses on explaining the principles of testing leaching behaviour of aggregates, and briefly explains the leaching of size reduced and non-size reduced particles. It provides information for the actual discussions on size reduction before leaching tests.

  4. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  5. Psychometric characteristics of single-word tests of children's speech sound production.

    Science.gov (United States)

    Flipsen, Peter; Ogiela, Diane A

    2015-04-01

    Our understanding of test construction has improved since the now-classic review by McCauley and Swisher (1984). The current review article examines the psychometric characteristics of current single-word tests of speech sound production in an attempt to determine whether our tests have improved since then. It also provides a resource that clinicians may use to help them make test selection decisions for their particular client populations. Ten tests published since 1990 were reviewed to determine whether they met the 10 criteria set out by McCauley and Swisher (1984), as well as 7 additional criteria. All of the tests reviewed met at least 3 of McCauley and Swisher's (1984) original criteria, and 9 of 10 tests met at least 5 of them. Most of the tests met some of the additional criteria as well. The state of the art for single-word tests of speech sound production in children appears to have improved in the last 30 years. There remains, however, room for improvement.

  6. MicroCHP: Overview of selected technologies, products and field test results

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Vollrad [Berliner Energieagentur GmbH, Franzoesische Strasse 23, 10117 Berlin (Germany); Klemes, Jiri; Bulatov, Igor [Centre for Process Integration, CEAS, The University of Manchester, P.O. Box 88, M60 1QD Manchester (United Kingdom)

    2008-11-15

    This paper gives an overview on selected microCHP technologies and products with the focus on Stirling and steam machines. Field tests in Germany, the UK and some other EC countries are presented, assessed and evaluated. Test results show the overall positive performance with differences in sectors (domestic vs. small business). Some negative experiences have been received, especially from tests with the Stirling engines and the free-piston steam machine. There are still obstacles for market implementation. Further projects and tests of microCHP are starting in various countries. When positive results will prevail and deficiencies are eliminated, a way to large-scale production and market implementation could be opened. (author)

  7. Product evaluation of in situ vitrification engineering, Test 4

    International Nuclear Information System (INIS)

    Loehr, C.A.; Weidner, J.R.; Bates, S.O.

    1991-09-01

    This report is one of several that evaluates the In Situ Vitrification (ISV) Engineering-Scale Test 4 (ES-4). This document describes the chemical and physical composition, microstructure, and leaching characteristics of ES-4 product samples; these data provide insight into the expected performance of a vitrified product in an ISV buried waste application similar to that studied in ES-4

  8. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  9. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  10. Testing controlled productive knowledge of adverb-verb collocations ...

    African Journals Online (AJOL)

    A controlled productive test of adverb-verb collocations ..... The third approach to studying collocations, corpus analysis, ..... The collocation web model is thought to match Nation's (2001) psychological .... Theory, analysis, and applications. .... Canadian Modern ... Focus on vocabulary: Mastering the Academic Word List.

  11. Method of reprocessing radioactive asphalt solidification products

    International Nuclear Information System (INIS)

    Nakaya, Iwao; Murakami, Tadashi; Miyake, Takafumi; Inagaki, Yuzo.

    1986-01-01

    Purpose: To obtain heat-stable solidification products and decrease the total volume thereof by modifying the solidified form by the reprocessing of existent radioactive asphalt solidification products. Method: Radioactive asphalt solidification products are heated into a fluidized state. Then, incombustible solvents such as perchloroethylene or trichloroethylene are added to a dissolving tank to gradually dissolve the radioactive asphalt solidification products. Thus, organic materials such as asphalts are transferred into the solvent layer, while inorganic materials containing radioactive materials remain as they are in the separation tank. Then, the inorganic materials containing the radioactive materials are taken out and then solidified, for example, by converting them into a rock or glass form. (Kawakami, Y.)

  12. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  13. Communication methods and production techniques in fixed prosthesis fabrication: a UK based survey. Part 2: Production techniques

    Science.gov (United States)

    Berry, J.; Nesbit, M.; Saberi, S.; Petridis, H.

    2014-01-01

    Aim The aim of this study was to identify the communication methods and production techniques used by dentists and dental technicians for the fabrication of fixed prostheses within the UK from the dental technicians' perspective. This second paper reports on the production techniques utilised. Materials and methods Seven hundred and eighty-two online questionnaires were distributed to the Dental Laboratories Association membership and included a broad range of topics, such as demographics, impression disinfection and suitability, and various production techniques. Settings were managed in order to ensure anonymity of respondents. Statistical analysis was undertaken to test the influence of various demographic variables such as the source of information, the location, and the size of the dental laboratory. Results The number of completed responses totalled 248 (32% response rate). Ninety percent of the respondents were based in England and the majority of dental laboratories were categorised as small sized (working with up to 25 dentists). Concerns were raised regarding inadequate disinfection protocols between dentists and dental laboratories and the poor quality of master impressions. Full arch plastic trays were the most popular impression tray used by dentists in the fabrication of crowns (61%) and bridgework (68%). The majority (89%) of jaw registration records were considered inaccurate. Forty-four percent of dental laboratories preferred using semi-adjustable articulators. Axial and occlusal under-preparation of abutment teeth was reported as an issue in about 25% of cases. Base metal alloy was the most (52%) commonly used alloy material. Metal-ceramic crowns were the most popular choice for anterior (69%) and posterior (70%) cases. The various factors considered did not have any statistically significant effect on the answers provided. The only notable exception was the fact that more methods of communicating the size and shape of crowns were utilised for

  14. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. 40 CFR 1048.301 - When must I test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... engines? 1048.301 Section 1048.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing Production-line Engines § 1048.301 When must I test my production-line engines? (a) If you produce engines...

  16. 40 CFR 1045.301 - When must I test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... engines? 1045.301 Section 1045.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Testing Production-line Engines § 1045.301 When must I test my production-line engines? (a) If you produce...

  17. 46 CFR 163.002-27 - Production tests and examination.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production tests and examination. 163.002-27 Section 163... examination. Each pilot hoist manufactured under Coast Guard approval must be tested as prescribed in § 163... laboratory must also conduct the visual examination described in § 163.002-21(b). The hoist may not be sold...

  18. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  19. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  20. Well test imaging - a new method for determination of boundaries from well test data

    Energy Technology Data Exchange (ETDEWEB)

    Slevinsky, B.A.

    1997-08-01

    A new method has been developed for analysis of well test data, which allows the direct calculation of the location of arbitrary reservoir boundaries which are detected during a well test. The method is based on elements of ray tracing and information theory, and is centered on the calculation of an instantaneous {open_quote}angle of view{close_quote} of the reservoir boundaries. In the absence of other information, the relative reservoir shape and boundary distances are retrievable in the form of a Diagnostic Image. If other reservoir information, such as 3-D seismic, is available; the full shape and orientation of arbitrary (non-straight line or circular arc) boundaries can be determined in the form of a Reservoir Image. The well test imaging method can be used to greatly enhance the information available from well tests and other geological data, and provides a method to integrate data from multiple disciplines to improve reservoir characterization. This paper covers the derivation of the analytical technique of well test imaging and shows examples of application of the technique to a number of reservoirs.

  1. Method of processing solidification product of radioactive waste

    International Nuclear Information System (INIS)

    Daime, Fumiyoshi.

    1988-01-01

    Purpose: To improve the long-time stability of solidification products by providing solidification products with liquid tightness, gas tightness, abrasion resistance, etc., of the products in the course of the solidification for the treatment of radioactive wastes. Method: The surface of solidification products prepared by mixing solidifying agents with powder or pellets is entirely covered with high molecular polymer such as epoxy resin. The epoxy resin has excellent properties such as radiation-resistance, heat resistance, water proofness and chemical resistance, as well as have satisfactory mechanical properties. This can completely isolate the solidification products of radioactive wastes from the surrounding atmosphere. (Yoshino, Y.)

  2. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  3. Method of producing gaseous products using a downflow reactor

    Science.gov (United States)

    Cortright, Randy D; Rozmiarek, Robert T; Hornemann, Charles C

    2014-09-16

    Reactor systems and methods are provided for the catalytic conversion of liquid feedstocks to synthesis gases and other noncondensable gaseous products. The reactor systems include a heat exchange reactor configured to allow the liquid feedstock and gas product to flow concurrently in a downflow direction. The reactor systems and methods are particularly useful for producing hydrogen and light hydrocarbons from biomass-derived oxygenated hydrocarbons using aqueous phase reforming. The generated gases may find used as a fuel source for energy generation via PEM fuel cells, solid-oxide fuel cells, internal combustion engines, or gas turbine gensets, or used in other chemical processes to produce additional products. The gaseous products may also be collected for later use or distribution.

  4. Remote methods of indicating oil products in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Shlyakhova, L A

    1981-01-01

    A survey is made of domestic and foreign publications covering remote methods of monitoring film petroleum products and oil in natural waters. The given methods are realized in practice with the use of different sections of the electromagnetic spectrum. Remote quality control of the natural waters at the modern level may be an indicator of water pollution with film petroleum products.

  5. Drying of water based foundry coatings: Innovative test, process design and optimization methods

    DEFF Research Database (Denmark)

    Di Muoio, Giovanni Luca; Johansen, Bjørn Budolph

    on real industrial cases. These tools have been developed in order to simulate and optimize the drying process and reduce drying time and power consumption as well as production process design time and cost of expensive drying equipment. Results show that test methods from other industries can be used...... capacity goals there is a need to understand how to design, control and optimize drying processes. The main focus of this project was on the critical parameters and properties to be controlled in production in order to achieve a stable and predictable drying process. We propose for each of these parameters...... of Denmark with the overall aim to optimize the drying process of water based foundry coatings. Drying of foundry coatings is a relatively new process in the foundry industry that followed the introduction of water as a solvent. In order to avoid moisture related quality problems and reach production...

  6. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  7. Comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1996-07-01

    In this paper the classical sequential probability ratio testing method (SPRT) is reconsidered. Every individual boundary crossing event of the SPRT is regarded as a new piece of evidence about the problem under hypothesis testing. The Bayes method is applied for belief updating, i.e. integrating these individual decisions. The procedure is recommended to use when the user (1) would like to be informed about the tested hypothesis continuously and (2) would like to achieve his final conclusion with high confidence level. (Author).

  8. Methods for high yield production of terpenes

    Energy Technology Data Exchange (ETDEWEB)

    Kutchan, Toni; Higashi, Yasuhiro; Feng, Xiaohong

    2017-01-03

    Provided are enhanced high yield production systems for producing terpenes in plants via the expression of fusion proteins comprising various combinations of geranyl diphosphate synthase large and small subunits and limonene synthases. Also provided are engineered oilseed plants that accumulate monoterpene and sesquiterpene hydrocarbons in their seeds, as well as methods for producing such plants, providing a system for rapidly engineering oilseed crop production platforms for terpene-based biofuels.

  9. Seismic test qualification of electrical equipment - testing methods in use to EDF

    International Nuclear Information System (INIS)

    Fabries, R.

    1981-01-01

    At the beginning, for the 900 MW Power Plant level, the testing method in application used the single axis test by sine beat of 10 cycles according to the specifications of the guide IEEE 344-71. When the french guide UTEC 20-420 came into force we have had to define another testing method (EDF standard: HN20 E52) which utilize the single-axis test either by a sine beat of 5-cycles or by a synthetized time history. We present here the mains criterions allowing to justify: -The single-axis test. The single frequency wave (when the Initial Response Spectrum (IRS) present a narrow band). The use of one sine beat of 5-cycles or one synthetized time history. The need of taking into account the high stress level. This oligocyclic stress fatigue explains why one beat of 5-cycles may be as severe as one time history of 20 seconds (with the same level of strong response spectrum). Then, we conclude that the durating of the testing wave applied to the equipment shall be considered as a relative parameter only. The weight of the SSE tests by respect to the OBE tests. The precautions to take in order to: generate and check accurately the synthetized time history, choice the test frequencies when the sine beat is used. (orig./HP)

  10. A method to evaluate fission gas release during irradiation testing of spherical fuel - HTR2008-58184

    International Nuclear Information System (INIS)

    Van Der Merwet, H.; Venter, J.

    2008-01-01

    The evaluation of fission gas release from spherical fuel during irradiation testing is critical to understand expected fuel performance under real reactor conditions. Online measurements of Krypton and Xenon fission products explain coated particle performance and contributions from graphitic matrix materials used in fuel manufacture and irradiation rig materials. Methods that are being developed to accurately evaluate fission gas release are described here together with examples of evaluations performed on irradiation tests HFR-K5, -K6 and EU1bis. (authors)

  11. A quantitative evaluation of the production performance of ice slurry by the oscillatory moving cooled wall method

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Masahiko; Fukusako, Shoichiro [Hokkaido Univ., Sapporo (Japan). Graduate School of Engineering; Kawabe, Hiromichi [Senshu Univ., Bibai (Japan). Hokkaido College. Dept. of Agricultural Engineering

    2002-03-01

    Ice slurry has recently been utilized for a variety of engineering fields such as thermal energy storage and high-density energy transportation. In this paper, as a production method of ice slurry, the oscillatory rotating cooled tube method was proposed. A vertical cooled tube was installed in a test vessel that was filled with ethylene glycol solution being forced to move within an aqueous binary solution to produce the ice slurry. Production performance of ice slurry by the present method was determined under a variety of conditions, such as initial concentration of solution, angular acceleration and rotation angle for the oscillation motion of the cooled tube. The production performance was evaluated analytically by constructing a numerical model. The analysis was made to determine the separation condition of ice layer from the cooled tube surface at first, then the production rate of ice slurry was assessed. It was found from the present study that the ice slurry was produced continuously under the appropriate operating conditions in which the separation of ice layer was caused by oscillating motion of the cooled tube. (Author)

  12. Standard Test Method for Measurement of Hydrogen Embrittlement Threshold in Steel by the Incremental Step Loading Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method establishes a procedure to measure the susceptibility of steel to a time-delayed failure such as that caused by hydrogen. It does so by measuring the threshold for the onset of subcritical crack growth using standard fracture mechanics specimens, irregular-shaped specimens such as notched round bars, or actual product such as fasteners (2) (threaded or unthreaded) springs or components as identified in SAE J78, J81, and J1237. 1.2 This test method is used to evaluate quantitatively: 1.2.1 The relative susceptibility of steels of different composition or a steel with different heat treatments; 1.2.2 The effect of residual hydrogen in the steel as a result of processing, such as melting, thermal mechanical working, surface treatments, coatings, and electroplating; 1.2.3 The effect of hydrogen introduced into the steel caused by external environmental sources of hydrogen, such as fluids and cleaners maintenance chemicals, petrochemical products, and galvanic coupling in an aqueous enviro...

  13. Improved Methods for Production Manufacturing Processes in Environmentally Benign Manufacturing

    Directory of Open Access Journals (Sweden)

    Yan-Yan Wang

    2011-09-01

    Full Text Available How to design a production process with low carbon emissions and low environmental impact as well as high manufacturing performance is a key factor in the success of low-carbon production. It is important to address concerns about climate change for the large carbon emission source manufacturing industries because of their high energy consumption and environmental impact during the manufacturing stage of the production life cycle. In this paper, methodology for determining a production process is developed. This methodology integrates process determination from three different levels: new production processing, selected production processing and batch production processing. This approach is taken within a manufacturing enterprise based on prior research. The methodology is aimed at providing decision support for implementing Environmentally Benign Manufacturing (EBM and low-carbon production to improve the environmental performance of the manufacturing industry. At the first level, a decision-making model for new production processes based on the Genetic Simulated Annealing Algorithm (GSAA is presented. The decision-making model considers not only the traditional factors, such as time, quality and cost, but also energy and resource consumption and environmental impact, which are different from the traditional methods. At the second level, a methodology is developed based on an IPO (Input-Process-Output model that integrates assessments of resource consumption and environmental impact in terms of a materials balance principle for batch production processes. At the third level, based on the above two levels, a method for determining production processes that focus on low-carbon production is developed based on case-based reasoning, expert systems and feature technology for designing the process flow of a new component. Through the above three levels, a method for determining the production process to identify, quantify, assess, and optimize the

  14. Test marketing of new smokeless tobacco products in four U.S. cities.

    Science.gov (United States)

    Rogers, John D; Biener, Lois; Clark, Pamela I

    2010-01-01

    This exploratory study was designed to assess the availability, price, and point-of-purchase marketing strategies for new smokeless tobacco products in 4 test market areas. A random sample of 50 gas stations, convenience and food stores, and tobacco shops was selected in each of 4 test market areas. Pairs of observers visited each store, recorded product information, and engaged vendors in conversation about product demand. Snus was available in 64% of the stores, but availability and price differed by brand. Point-of-purchase marketing also varied by brand on a variety of dimensions and all brands appeared to be marketed primarily to smokers. Camel Snus was described by store attendants as having the highest demand and was also the most expensive of the observed products. In light of the number of test market cities and intensity of promotion at retail locations, Camel Snus was the most intensively marketed product. The results appear to reflect differences in marketing strategy by American snus manufacturers. These strategies may help to predict future marketing of snus and other tobacco products and may provide a baseline for later assessments of product acceptance.

  15. From the Kirsch-Kress potential method via the range test to the singular sources method

    International Nuclear Information System (INIS)

    Potthast, R; Schulz, J

    2005-01-01

    We review three reconstruction methods for inverse obstacle scattering problems. We will analyse the relation between the Kirsch-Kress potential method 1986, the range test of Kusiak, Potthast and Sylvester (2003) and the singular sources method of Potthast (2000). In particular, we show that the range test is a logical extension of the Kirsch-Kress method into the category of sampling methods employing the tool of domain sampling. Then we will show how a multi-wave version of the range test can be set up and we will work out its relation to the singular sources method. Numerical examples and demonstrations will be provided

  16. Development of construction methods for high-density bentonite barriers using premixed spraying. Part 1. Laboratory tests on methods of spraying roughly crushed bentonite and investigation of mixing methods

    International Nuclear Information System (INIS)

    Kobayashi, Ichizo; Tanaka, Toshiyuki; Nakajima, Makoto; Toida, Masaru

    2006-01-01

    According to the present concept of geological disposal of radioactive waste, a disposal facility should consist of a bentonite-engineered barrier, a cementitious-engineered barrier, and natural barriers. To guarantee the validity of the geological disposal concept, the bentonite-engineered barrier must have high impermeability. However, an effective construction method for high-density bentonite-engineered barriers in narrow spaces such as those in radioactive waste geological disposal sites has not been developed. Therefore, the authors have developed a spraying method that has high workability in narrow spaces as a method of constructing bentonite-engineered barriers in narrow spaces. This paper describes the production method for a spraying material and an examination through spraying tests of the spraying distance, the shapes of the spray nozzles, and the ratio of spraying material to air. The test results confirmed that a bentonite-engineered barrier of dry density 1.6 Mg/m 3 could be constructed using the spraying method developed and that the appropriate spraying conditions for the construction of high-density bentonite barriers were obtained. Moreover, the authors developed a construction quality management method using the silicon oil specific-gravity method that can clearly and promptly indicate the dry density of the sprayed bentonite. (author)

  17. An efficient, maintenance free and approved method for spectroscopic control and monitoring of blend uniformity: The moving F-test.

    Science.gov (United States)

    Besseling, Rut; Damen, Michiel; Tran, Thanh; Nguyen, Thanh; van den Dries, Kaspar; Oostra, Wim; Gerich, Ad

    2015-10-10

    Dry powder mixing is a wide spread Unit Operation in the Pharmaceutical industry. With the advent of in-line Near Infrared (NIR) Spectroscopy and Quality by Design principles, application of Process Analytical Technology to monitor Blend Uniformity (BU) is taking a more prominent role. Yet routine use of NIR for monitoring, let alone control of blending processes is not common in the industry, despite the improved process understanding and (cost) efficiency that it may offer. Method maintenance, robustness and translation to regulatory requirements have been important barriers to implement the method. This paper presents a qualitative NIR-BU method offering a convenient and compliant approach to apply BU control for routine operation and process understanding, without extensive calibration and method maintenance requirements. The method employs a moving F-test to detect the steady state of measured spectral variances and the endpoint of mixing. The fundamentals and performance characteristics of the method are first presented, followed by a description of the link to regulatory BU criteria, the method sensitivity and practical considerations. Applications in upscaling, tech transfer and commercial production are described, along with evaluation of the method performance by comparison with results from quantitative calibration models. A full application, in which end-point detection via the F-test controls the blending process of a low dose product, was successfully filed in Europe and Australia, implemented in commercial production and routinely used for about five years and more than 100 batches. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Methods for conversion of lignocellulosic-derived products to transportation fuel precursors

    Science.gov (United States)

    Lilga, Michael A.; Padmaperuma, Asanga B.

    2017-10-03

    Methods are disclosed for converting a biomass-derived product containing levulinic acid and/or gamma-valerolactone to a transportation fuel precursor product containing diesel like hydrocarbons. These methods are expected to produce fuel products at a reduced cost relative to conventional approaches.

  19. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  20. pp production cross sections and the constraint method

    International Nuclear Information System (INIS)

    Anjos, J.C.; Santoro, A.F.S.; Souza, M.H.G.

    1983-01-01

    A method of constructing production cross sections that satisfy the constraints represented by the first few moments is shown to give an excellent account of the data when applied to the high energy pp production cross section ν sub(n) (s) plotted as functions of n. (Author) [pt

  1. Electrical production testing of the D0 Silicon microstrip tracker detector modules

    Energy Technology Data Exchange (ETDEWEB)

    D0, SMT Production Testing Group; /Fermilab

    2006-03-01

    The D0 Silicon Microstrip Tracker (SMT) is the innermost system of the D0 detector in Run 2. It consists of 912 detector units, corresponding to 5 different types of assemblies, which add up to a system with 792,576 readout channels. The task entrusted to the Production Testing group was to thoroughly debug, test and grade each detector module before its installation in the tracker. This note describes the production testing sequence and the procedures by which the detector modules were electrically tested and characterized at the various stages of their assembly.

  2. Gemfibrozil and carbamazepine decrease steroid production in zebrafish testes (Danio rerio).

    Science.gov (United States)

    Fraz, Shamaila; Lee, Abigail H; Wilson, Joanna Y

    2018-05-01

    Gemfibrozil (GEM) and carbamazepine (CBZ) are two environmentally relevant pharmaceuticals and chronic exposure of fish to these compounds has decreased androgen levels and fish reproduction in laboratory studies. The main focus of this study was to examine the effects of GEM and CBZ on testicular steroid production, using zebrafish as a model species. Chronic water borne exposures of adult zebrafish to 10 μg/L of GEM and CBZ were conducted and the dosing was confirmed by chemical analysis of water as 17.5 ± 1.78 and 11.2 ± 1.08 μg/L respectively. A 67 day exposure led to reduced reproductive output and lowered whole body, plasma, and testicular 11-ketotestosterone (11-KT). Testicular production of 11-KT was examined post exposure (42 days) using ex vivo cultures to determine basal and stimulated steroid production. The goal was to ascertain the step impaired in the steroidogenic pathway by each compound. Ex vivo 11-KT production in testes from males chronically exposed to GEM and CBZ was lower than that from unexposed males. Although hCG, 25-OH cholesterol, and pregnenolone stimulation increased 11-KT production in all treatment groups over basal levels, hCG stimulated 11-KT production remained significantly less in testes from exposed males compared to controls. 25-OH cholesterol and pregnenolone stimulated 11-KT production was similar between GEM and control groups but the CBZ group had lower 11-KT production than controls with both stimulants. We therefore propose that chronic GEM and CBZ exposure can reduce production of 11-KT in testes through direct effects independent of mediation through HPG axis. The biochemical processes for steroid production appear un-impacted by GEM exposure; while CBZ exposure may influence steroidogenic enzyme expression or function. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Methods for production of aluminium powders and their application fields

    Energy Technology Data Exchange (ETDEWEB)

    Gopienko, V.G.; Kiselev, V.P.; Zobnina, N.S. (Vsesoyuznyj Nauchno-Issledovatel' skij i Proektnyj Inst. Alyuminievoj, magnievoj i ehlektrodnoj promyshlennosti (USSR))

    1984-12-01

    Different types of powder products made of alluminium and its alloys (powder, fine powders, granules and pastes) as well as their basic physicochemical properties are briefly characterized. The principle methods for alluminium powder production are outlined: physicochemical methods, the melt spraying by compressed gas being the mostly developed among them, and physico-mechanical ones. Main application spheres for powder productions of aluminium and its alloys are reported in short.

  4. Methods for production of aluminium powders and their application fields

    International Nuclear Information System (INIS)

    Gopienko, V.G.; Kiselev, V.P.; Zobnina, N.S.

    1984-01-01

    Different types of powder products made of alluminium and its alloys (powder, fine powders, granules and pastes) as well as their basic physicochemical properties are briefly characterized. The principle methods for alluminium powder production are outlined: physicochemical methods, the melt spraying by compressed gas being the mostly developed among them, and physico-mechanical ones. Main application spheres for powder productions of aluminium and its alloys are reported in short

  5. 40 CFR 60.85 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... flow rate of the effluent gas, dscm/hr (dscf/hr). P=production rate of 100 percent H2SO4, metric ton/hr... the volumetric flow rate and production rate: (i) The integrated technique of Method 3 is used to... mist and SO2 concentrations (C's) and the volumetric flow rate (Qsd) of the effluent gas. The moisture...

  6. Advanced display object selection methods for enhancing user-computer productivity

    Science.gov (United States)

    Osga, Glenn A.

    1993-01-01

    The User-Interface Technology Branch at NCCOSC RDT&E Division has been conducting a series of studies to address the suitability of commercial off-the-shelf (COTS) graphic user-interface (GUI) methods for efficiency and performance in critical naval combat systems. This paper presents an advanced selection algorithm and method developed to increase user performance when making selections on tactical displays. The method has also been applied with considerable success to a variety of cursor and pointing tasks. Typical GUI's allow user selection by: (1) moving a cursor with a pointing device such as a mouse, trackball, joystick, touchscreen; and (2) placing the cursor on the object. Examples of GUI objects are the buttons, icons, folders, scroll bars, etc. used in many personal computer and workstation applications. This paper presents an improved method of selection and the theoretical basis for the significant performance gains achieved with various input devices tested. The method is applicable to all GUI styles and display sizes, and is particularly useful for selections on small screens such as notebook computers. Considering the amount of work-hours spent pointing and clicking across all styles of available graphic user-interfaces, the cost/benefit in applying this method to graphic user-interfaces is substantial, with the potential for increasing productivity across thousands of users and applications.

  7. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods

    Science.gov (United States)

    Dozier, Samantha; Brown, Jeffrey; Currie, Alistair

    2011-01-01

    Simple Summary Many vaccines are tested for quality in experiments that require the use of large numbers of animals in procedures that often cause significant pain and distress. Newer technologies have fostered the development of vaccine quality control tests that reduce or eliminate the use of animals, but the availability of these newer methods has not guaranteed their acceptance by regulators or use by manufacturers. We discuss a strategic approach that has been used to assess and ultimately increase the use of non-animal vaccine quality tests in the U.S. and U.K. Abstract In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches. PMID:26486625

  8. IMPLEMENTATION OF CONTROL CARDS AND SUPPORTING METHOD IN PRODUCTION ENGINEERING

    Directory of Open Access Journals (Sweden)

    Anna WOLNOWSKA

    2012-10-01

    Full Text Available In the article there were presented chosen method associated with statistical control of production processes. Mainly focused on control cards and Pareto‐Lorenz analysis. Showed method were implemented to analysis production process stability of hearing aids in X company (the brand name don’t give because date of production is secret. Researches were made few months after new assembly lines starts‐up. Main aim of researches was defects types identification occurred in production process and determine the scale of effect. Finally received results were satisfactory, i.e. despite of occurred errors, control cards analysis showed that production process of BTE‐type (Behind‐The‐Ear hearing aids was stable.

  9. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  10. A practical comparison of methods to assess sum-of-products

    International Nuclear Information System (INIS)

    Rauzy, A.; Chatelet, E.; Dutuit, Y.; Berenguer, C.

    2003-01-01

    Many methods have been proposed in the literature to assess the probability of a sum-of-products. This problem has been shown computationally hard (namely no. P-hard). Therefore, algorithms can be compared only from a practical point of view. In this article, we propose first an efficient implementation of the pivotal decomposition method. This kind of algorithms is widely used in the Artificial Intelligence framework. It is unfortunately almost never considered in the reliability engineering framework, but as a pedagogical tool. We report experimental results that show that this method is in general much more efficient than classical methods that rewrite the sum-of-products under study into an equivalent sum of disjoint products. Then, we derive from our method a factorization algorithm to be used as a preprocessing method for binary decision diagrams. We show by means of experimental results that this latter approach outperforms the formers

  11. 77 FR 49063 - Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products

    Science.gov (United States)

    2012-08-15

    ... Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products; Proposed...-AC01 Energy Conservation Program: Test Procedures for Residential Dishwashers and Cooking Products... procedures for both dishwashers and conventional cooking products for the measurement of energy use in fan...

  12. 76 FR 69585 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2011-11-08

    ... 1107 Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for... [CPSC Docket No. CPSC-2011-0082] Testing and Labeling Pertaining to Product Certification Regarding... to Product Certification.'' The proposed rule was intended to implement what was then known as...

  13. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  14. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  15. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  16. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  17. Methods and systems for chemoautotrophic production of organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Curt R.; Che, Austin J.; Shetty, Reshma P.; Kelly, Jason R.

    2018-02-27

    The present disclosure identifies pathways, mechanisms, systems and methods to confer chemoautotrophic production of carbon-based products of interest, such as sugars, alcohols, chemicals, amino acids, polymers, fatty acids and their derivatives, hydrocarbons, isoprenoids, and intermediates thereof, in organisms such that these organisms efficiently convert inorganic carbon to organic carbon-based products of interest using inorganic energy, such as formate, and in particular the use of organisms for the commercial production of various carbon-based products of interest.

  18. Non-parametric tests of productive efficiency with errors-in-variables

    NARCIS (Netherlands)

    Kuosmanen, T.K.; Post, T.; Scholtes, S.

    2007-01-01

    We develop a non-parametric test of productive efficiency that accounts for errors-in-variables, following the approach of Varian. [1985. Nonparametric analysis of optimizing behavior with measurement error. Journal of Econometrics 30(1/2), 445-458]. The test is based on the general Pareto-Koopmans

  19. Standard test method for measurement of light reflectance value and small color differences between pieces of ceramic tile

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of Light Reflectance Value (LRV) and visually small color difference between pieces of glazed or unglazed ceramic tile, using any spectrophotometer that meets the requirements specified in the test method. LRV and the magnitude and direction of the color difference are expressed numerically, with sufficient accuracy for use in product specification. 1.2 LRV may be measured for either solid-colored tile or tile having a multicolored, speckled, or textured surface. For tile that are not solid-colored, an average reading should be obtained from multiple measurements taken in a pattern representative of the overall sample as described in 9.2 of this test method. Small color difference between tiles should only be measured for solid-color tiles. Small color difference between tile that have a multicolored, speckled, or textured surface, are not valid. 1.3 For solid colored tile, a comparison of the test specimen and reference specimen should be made under incandescent, f...

  20. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  1. Analysis and results of a hydrogen-moderated isotope production assembly in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Wootan, D.W.; Rawlins, J.A.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1989-01-01

    This paper reports on a cobalt test assembly containing yttrium hydride pins for neutron moderation irradiated in the Fast Flux Test Facility (FFTF) during cycle 9A for 137.7 equivalent full-power days at a power level of 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal used to produce 60 Co and a set of four pins with europium oxide to produce 153 Gd, a radioisotope used in detection of the bone disease osteoporosis. Postirradiation examination of the cobalt pins determined the 60 Co production to be predictable to an accuracy of ∼ 5%. The measured 60 Co spatially distributed concentrations were within 20% of the calculated concentrations. The assembly average 60 Co measured activity was 4% less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes 152 Eu and 154 Eu to an absolute accuracy of ≅ 10%. The measured europium radioisotope and 153 Gd concentrations were within 20% of calculated values. The hydride assembly performed well and is an excellent vehicle for many FFTF isotope production applications. The results also demonstrate the accuracy of the calculational methods developed by the Westinghouse Hanford Company for predicting isotope production rates in this type of assembly

  2. Test marketing for value-added root and tuber based products in ...

    African Journals Online (AJOL)

    Test marketing for value-added root and tuber based products in Ikwuano local government area ... JE Ewuziem, C Aniedu, E Oti, VO Onyenobi ... root and tuber based products, developed at National Root Crops Research Institute, Umudike.

  3. 78 FR 68076 - Request for Information on Alternative Skin Sensitization Test Methods and Testing Strategies and...

    Science.gov (United States)

    2013-11-13

    ... Laboratory for Alternatives to Animal Testing (EURL ECVAM), and by the industry organization Cosmetics Europe... products. Pesticides and other marketed chemicals, including cosmetic ingredients, are routinely tested for... sensitization. NICEATM collaboration with industry scientists to develop an open-source Bayesian network as an...

  4. Hydrocarbon productivities in different Botryococcus strains: comparative methods in product quantification.

    Science.gov (United States)

    Eroglu, Ela; Okada, Shigeru; Melis, Anastasios

    2011-08-01

    Six different strains of the green microalgae Botryococcus belonging to the A-race or B-race, accumulating alkadiene or botryococcene hydrocarbons, respectively, were compared for biomass and hydrocarbon productivities. Biomass productivity was assessed gravimetrically upon strain growth in the laboratory under defined conditions. Hydrocarbon productivities were measured by three different and independent experimental approaches, including density equilibrium of the intact cells and micro-colonies, spectrophotometric analysis of hydrocarbon extracts, and gravimetric quantitation of eluted hydrocarbons. All three hydrocarbon-quantitation methods yielded similar results for each of the strains examined. The B-race microalgae Botryococcus braunii var. Showa and Kawaguchi-1 constitutively accumulated botryococcene hydrocarbons equivalent to 30% and 20%, respectively, of their overall biomass. The A-race microalgae Botryococcus braunii, varieties Yamanaka, UTEX 2441 and UTEX LB572 constitutively accumulated alkadiene hydrocarbons ranging from 14% to 13% and 10% of their overall biomass, respectively. Botryococcus sudeticus (UTEX 2629), a morphologically different green microalga, had the lowest hydrocarbon accumulation, equal to about 3% of its overall biomass. Results validate the density equilibrium and spectrophotometric analysis methods in the quantitation of botryococcene-type hydrocarbons. These analytical advances will serve in the screening and selection of B. braunii and of other microalgae in efforts to identify those having a high hydrocarbon content for use in commercial applications.

  5. Studying the co-evolution of production and test code in open source and industrial developer test processes through repository mining

    NARCIS (Netherlands)

    Zaidman, A.; Van Rompaey, B.; Van Deursen, A.; Demeyer, S.

    2010-01-01

    Many software production processes advocate rigorous development testing alongside functional code writing, which implies that both test code and production code should co-evolve. To gain insight in the nature of this co-evolution, this paper proposes three views (realized by a tool called TeMo)

  6. Testing of toxicity based methods to develop site specific clean up objectives - phase 1: Toxicity protocol screening and applicability

    International Nuclear Information System (INIS)

    Hamilton, H.; Kerr, D.; Thorne, W.; Taylor, B.; Zadnik, M.; Goudey, S.; Birkholz, D.

    1994-03-01

    A study was conducted to develop a cost-effective and practical protocol for using bio-assay based toxicity assessment methods for remediation of decommissioned oil and gas production, and processing facilities. The objective was to generate site-specific remediation criteria for contaminated sites. Most companies have used the chemical-specific approach which, however, did not meet the ultimate land use goal of agricultural production. The toxicity assessment method described in this study dealt with potential impairment to agricultural crop production and natural ecosystems. Human health concerns were not specifically addressed. It was suggested that chemical-specific methods should be used when human health concerns exist. . Results showed that toxicity tests will more directly identify ecological stress caused by site contamination than chemical-specific remediation criteria, which can be unnecessarily protective. 11 refs., 7 tabs., 6 figs

  7. Setup, tests and results for the ATLAS TileCal Read Out Driver production

    CERN Document Server

    Valero, Alberto; Castillo, V; Cuenca, C; Ferrer, A; Fullana, E; González, V; Higón, E; Munar, A; Poveda, J; Ruiz-Martínez, A; Salvachúa, B; Sanchís, E; Solans, C; Soret, J; Torres, J; Valls, J A

    2007-01-01

    In this paper we describe the performance and test results of the production of the 38 ATLAS TileCal Read Out Drivers (RODs). We first describe the basic hardware specifications and firmware functionality of the modules, the test-bench setup used for production and the test procedure to qualify the boards. We then finally show and discuss the performance results.

  8. Possible checking of technical parameters in nondestructive materials and products testing

    International Nuclear Information System (INIS)

    Kesl, J.

    1987-01-01

    The requirements are summed up for partial technical parameters of instruments and facilities for nondestructive testing by ultrasound, radiography, by magnetic, capillary and electric induction methods. The requirements and procedures for testing instrument performance are presented for the individual methods as listed in domestic and foreign standards, specifications and promotional literature. The parameters to be tested and the methods of testing, including the testing and calibration instruments are shown in tables. The Czechoslovak standards are listed currently valid for nondestructive materials testing. (M.D.)

  9. The radiological testing of consumer products 1976-1978

    International Nuclear Information System (INIS)

    Wilkins, B.T.; Dixon, D.W.

    1979-02-01

    The National Radiological Protection Board's source testing laboratory has been operational since 1976. In the intervening period the types of consumer product which have received most attention have been ionisation chamber smoke detectors and liquid crystal digital watches containing gaseous tritium light sources; the results obtained on these two types of device are the main subject of this report. The report also traces the development of the practical appraisal of these devices by the Board and describes the part played by the test results in the evolution of national and international standards. (author)

  10. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  11. Evaluation of Statistical Methods for Modeling Historical Resource Production and Forecasting

    Science.gov (United States)

    Nanzad, Bolorchimeg

    This master's thesis project consists of two parts. Part I of the project compares modeling of historical resource production and forecasting of future production trends using the logit/probit transform advocated by Rutledge (2011) with conventional Hubbert curve fitting, using global coal production as a case study. The conventional Hubbert/Gaussian method fits a curve to historical production data whereas a logit/probit transform uses a linear fit to a subset of transformed production data. Within the errors and limitations inherent in this type of statistical modeling, these methods provide comparable results. That is, despite that apparent goodness-of-fit achievable using the Logit/Probit methodology, neither approach provides a significant advantage over the other in either explaining the observed data or in making future projections. For mature production regions, those that have already substantially passed peak production, results obtained by either method are closely comparable and reasonable, and estimates of ultimately recoverable resources obtained by either method are consistent with geologically estimated reserves. In contrast, for immature regions, estimates of ultimately recoverable resources generated by either of these alternative methods are unstable and thus, need to be used with caution. Although the logit/probit transform generates high quality-of-fit correspondence with historical production data, this approach provides no new information compared to conventional Gaussian or Hubbert-type models and may have the effect of masking the noise and/or instability in the data and the derived fits. In particular, production forecasts for immature or marginally mature production systems based on either method need to be regarded with considerable caution. Part II of the project investigates the utility of a novel alternative method for multicyclic Hubbert modeling tentatively termed "cycle-jumping" wherein overlap of multiple cycles is limited. The

  12. 40 CFR 1045.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1045.305 Section 1045.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION MARINE ENGINES AND VESSELS Testing Production-line Engines § 1045.305 How must I prepare and test my production-line engines...

  13. 40 CFR 1048.305 - How must I prepare and test my production-line engines?

    Science.gov (United States)

    2010-07-01

    ... production-line engines? 1048.305 Section 1048.305 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing Production-line Engines § 1048.305 How must I prepare and test my production-line engines? This...

  14. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  15. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-02-21

    ... Prototype testing.... Manufacturers must obtain Units with rated All tests use the Units with rated (160.151... Liferafts Prototype testing.... Existing Certificates of No cost or benefit as All tests use the Costs of... designs, overseeing prototype construction, witnessing prototype testing, and monitoring production of the...

  16. Development of a test method for sowing machines concerning the drift of dust abrasion

    Directory of Open Access Journals (Sweden)

    Bahmer, Roland

    2014-02-01

    Full Text Available For a long time the seed treatment was regarded as the most effective and in terms of the impact of the natural environment as the safest form of plant protection. Since the serious damage of bees, caused by dust of abraded seed treatment in the Rhine Valley five years ago, the admission of seed treatment products containing insecticide is in the discussion. To evaluate the emission characteristics of sowing machines during sowing based on secure data, the technical basis for a test method for measuring the drift of abraded seed-dust in sowing machines were developed at the Centre for Agricultural Technology Augustenberg. An indoor test bench was created and a standardized test method by which it is possible to evaluate the drift behavior of sowing machines in comparison was developed. A granulate which is stained with a fluorescent Tracer is used as test seed. The „tracer technique“ allows a reproducible, rapid and inexpensive assessment of the drift behavior of the sowing technology, which is commonly used. To classify the obtained drift values in the test bench, measurements in the field were carried out for comparison. The determined drift volumes of those measurements were at a similar level as the measured values in the test stand. Therefore the standardized measurement of drift in the test stand is suitable for the calculation of exposure scenarios for the sowing of treated seeds.

  17. A QFD-based optimization method for a scalable product platform

    Science.gov (United States)

    Luo, Xinggang; Tang, Jiafu; Kwong, C. K.

    2010-02-01

    In order to incorporate the customer into the early phase of the product development cycle and to better satisfy customers' requirements, this article adopts quality function deployment (QFD) for optimal design of a scalable product platform. A five-step QFD-based method is proposed to determine the optimal values for platform engineering characteristics (ECs) and non-platform ECs of the products within a product family. First of all, the houses of quality (HoQs) for all product variants are developed and a QFD-based optimization approach is used to determine the optimal ECs for each product variant. Sensitivity analysis is performed for each EC with respect to overall customer satisfaction (OCS). Based on the obtained sensitivity indices of ECs, a mathematical model is established to simultaneously optimize the values of the platform and the non-platform ECs. Finally, by comparing and analysing the optimal solutions with different number of platform ECs, the ECs with which the worst OCS loss can be avoided are selected as platform ECs. An illustrative example is used to demonstrate the feasibility of this method. A comparison between the proposed method and a two-step approach is conducted on the example. The comparison shows that, as a kind of single-stage approach, the proposed method yields better average degree of customer satisfaction due to the simultaneous optimization of platform and non-platform ECs.

  18. Problems of metrological supply of carbon materials production

    International Nuclear Information System (INIS)

    Belov, G.V.; Bazilevskij, L.P.; Cherkashina, N.V.

    1989-01-01

    Carbon materials and products contain internal residual stresses and have an anisotropy of properties therefore special methods of tests are required to control their quality. The main metrological problems during development, production and application of carbon products are: metrological supply of production forms and records during the development of production conditions; metrological supply of quality control of the product; metrological supply of methods for the tests of products and the methods to forecast the characteristics of product quality for the period of quaranteed service life

  19. New chromatographic method for separating Omeprazole from its degradation components and the quantitatively determining it in its pharmaceutical products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.; Seuleiman, M.

    2007-01-01

    New chromatographic method for Quantitative Determination of Omeprazole in its Pharmaceutical Products was produced. Omeprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ) ).(author)

  20. New chromatographic Methods for Separation of Lansoprazole from its Degradation Components and The Quantitative Determination in its Pharmaceutical Products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.

    2009-01-01

    New chromatographic method was found for Quantitative Determination of Lansoprazole in its pharmaceutical products. Lansoprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ)). (author)

  1. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  2. Selection of a leaching test method for waste product conformity verification

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A., E-mail: isabel.lopes@cdtn.br, E-mail: tellocc@cdtn.br, E-mail: hauczmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  3. Selection of a leaching test method for waste product conformity verification

    International Nuclear Information System (INIS)

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A.

    2017-01-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  4. Well test: production analysis and allocation measurement; Teste de poco: analise da producao e medicao de apropriacao

    Energy Technology Data Exchange (ETDEWEB)

    Geron, Luis Carlos [Smar Equipamentos Industriais Ltda., Sertaozinho, SP (Brazil). Dept. de Engenharia Aplicacoes; Tateishi, Sergio Hideki [Smar Equipamentos Industriais Ltda, Sertaozinho, SP (Brazil). Dept. de Pesquisa e Desenvolvimento

    2008-07-01

    The well test is an instrument frequently used to evaluate the production capacity of wells and it usually has specific requirements in the flow measurement, that are not necessary in the flow measurement system for custody transfer applications. Starting with the requirement to measure the injected product in the well when it is in the recuperation phase and it also includes compliance to specific standards for allocation measurement, because these hydrocarbon products are not treated as well as that ones in the production streams. Other important issue associated to the well test is the employment of new technologies, that helps to reduce the uncertainty of measurement as digital communication between the field devices and the flow computer through an open protocol as the Foundation Field bus. Another indication of technology evolution in the flow measurement focusing a lower uncertainty is the new version of API MPMS 11.1:2004, that requires calculation with double precision floating point, as well the correction factors with 5 decimal digits. (author)

  5. Comments on Thermal Physical Properties Testing Methods of Phase Change Materials

    Directory of Open Access Journals (Sweden)

    Jingchao Xie

    2013-01-01

    Full Text Available There is no standard testing method of the thermal physical properties of phase change materials (PCM. This paper has shown advancements in this field. Developments and achievements in thermal physical properties testing methods of PCM were commented, including differential scanning calorimetry, T-history measurement, the water bath method, and differential thermal analysis. Testing principles, advantages and disadvantages, and important points for attention of each method were discussed. A foundation for standardized testing methods for PCM was made.

  6. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  7. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  8. Performing Pumping Test Data Analysis Applying Cooper-Jacob’s Method for Estimating of the Aquifer Parameters

    Directory of Open Access Journals (Sweden)

    Dana Khider Mawlood

    2016-06-01

    Full Text Available Single well test is more common than aquifer test with having observation well, since the advantage of single well test is that the pumping test can be conducted on the production well with the absence of observation well. A kind of single well test, which is step-drawdown test used to determine the efficiency and specific capacity of the well, however in case of single well test it is possible to estimate Transmissivity, but the other parameter which is Storativity is overestimated, so the aim of this study is to analyze four pumping test data located in KAWRGOSK area by using cooper-Jacob’s (1946 time drawdown approximation of Theis method to estimate the aquifer parameters, also in order to determine the reasons which are affecting the reliability of the Storativity value and obtain the important aspect behind that in practice.

  9. Decision method for optimal selection of warehouse material handling strategies by production companies

    Science.gov (United States)

    Dobos, P.; Tamás, P.; Illés, B.

    2016-11-01

    Adequate establishment and operation of warehouse logistics determines the companies’ competitiveness significantly because it effects greatly the quality and the selling price of the goods that the production companies produce. In order to implement and manage an adequate warehouse system, adequate warehouse position, stock management model, warehouse technology, motivated work force committed to process improvement and material handling strategy are necessary. In practical life, companies have paid small attantion to select the warehouse strategy properly. Although it has a major influence on the production in the case of material warehouse and on smooth costumer service in the case of finished goods warehouse because this can happen with a huge loss in material handling. Due to the dynamically changing production structure, frequent reorganization of warehouse activities is needed, on what the majority of the companies react basically with no reactions. This work presents a simulation test system frames for eligible warehouse material handling strategy selection and also the decision method for selection.

  10. New test method for the evaluation of the preservation efficacy of soaps at very alkaline pH made by saponification.

    Science.gov (United States)

    Témoin-Fardini, S; Servant, J; Sellam, S

    2017-10-01

    The aim of this study was to develop a test method to evaluate the preservation efficacy for a specific product, a very high-alkaline liquid soap (pH around 10) made by a saponification process. Several manufacturers have experienced contamination issues with these high-pH soaps despite passing a classic preservative efficacy challenge test or even a multi-inoculation challenge test. Bacteria were isolated from contaminated soaps and were identified using 16S rRNA gene sequencing. High-alkaline-pH unpreserved soaps were tested using the Thor Personal Care internal multichallenge test method (TM206) with classical microorganisms and then with the bacterial strains isolated from various contaminated soaps (TM768). Preservatives were added to these soaps and assessed for their efficacy using the newly developed test. Four different species of bacteria (Nesterenkonia lacusekhoensis, Dermacoccus sp., Halomonas sp. and Roseomonas sp.) were identified by sequencing among the contaminants of the various soaps tested. Among these, only one bacterial species, Nesterenkonia lacusekhoensis, appeared to be responsible for the specific contamination of these high-alkaline soaps. Thus, one specific wild-type strain of Nesterenkonia lacusekhoensis, named as strain 768, was used in a new multi-inoculation test (TM768). Unlike the single inoculation challenge test, the multi-inoculation test using the Nesterenkonia strain 768 was able to predict the sensitivity of a product towards this bacterium. Among the 27 different preservatives tested, 10 were able to protect the formula against contamination with this bacterium. This study enabled the development of a test method to evaluate the efficacy of preservation using a specific bacterium, Nesterenkonia lacusekhoensis, responsible for the contamination of very alkaline soaps made by saponification and identify an appropriate preservative system. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  11. Methods for production of proteins in host cells

    Science.gov (United States)

    Donnelly, Mark; Joachimiak, Andrzej

    2004-01-13

    The present invention provides methods for the production of proteins, particularly toxic proteins, in host cells. The invention provides methods which use a fusion protein comprising a chaperonin binding domain in host cells induced or regulated to have increased levels of chaperonin which binds the chaperonin binding domain.

  12. Germanium recovery from gasification fly ash: evaluation of end-products obtained by precipitation methods.

    Science.gov (United States)

    Arroyo, Fátima; Font, Oriol; Fernández-Pereira, Constantino; Querol, Xavier; Juan, Roberto; Ruiz, Carmen; Coca, Pilar

    2009-08-15

    In this study the purity of the germanium end-products obtained by two different precipitation methods carried out on germanium-bearing solutions was evaluated as a last step of a hydrometallurgy process for the recovery of this valuable element from the Puertollano Integrated Gasification Combined Cycle (IGCC) fly ash. Since H(2)S is produced as a by-product in the gas cleaning system of the Puertollano IGCC plant, precipitation of germanium as GeS(2) was tested by sulfiding the Ge-bearing solutions. The technological and hazardous issues that surround H(2)S handling conducted to investigate a novel precipitation procedure: precipitation as an organic complex by adding 1,2-dihydroxy benzene pyrocatechol (CAT) and cetyltrimethylammonium bromide (CTAB) to the Ge-bearing solutions. Relatively high purity Ge end-products (90 and 93% hexagonal-GeO(2) purity, respectively) were obtained by precipitating Ge from enriched solutions, as GeS(2) sulfiding the solutions with H(2)S, or as organic complex with CAT/CTAB mixtures and subsequent roasting of the precipitates. Both methods showed high efficiency (>99%) to precipitate selectively Ge using a single precipitation stage from germanium-bearing solutions.

  13. 49 CFR Appendix B to Part 178 - Alternative Leakproofness Test Methods

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Alternative Leakproofness Test Methods B Appendix... FOR PACKAGINGS Pt. 178, App. B Appendix B to Part 178—Alternative Leakproofness Test Methods In addition to the method prescribed in § 178.604 of this subchapter, the following leakproofness test methods...

  14. Parametric effects on glass reaction in the unsaturated test method

    International Nuclear Information System (INIS)

    Woodland, A.B.; Bates, J.K.; Gerding, T.J.

    1991-12-01

    The Unsaturated Test Method has been applied to study glass reaction under conditions that may be present at the potential Yucca Mountain site, currently under evaluation for storage of reprocessed high-level nuclear waste. The results from five separate sets of parametric experiments are presented wherein test parameters ranging from water contact volume to sensitization of metal in contact with the glass were examined. The most significant effect was observed when the volume of water, as controlled by the water inject volume and interval period, was such to allow exfoliation of reacted glass to occur. The extent of reaction was also influenced to a lesser extent by the degree of sensitization of the 304L stainless steel. For each experiment, the release of cations from the glass and alteration of the glass were examined. The major alteration product is a smectite clay that forms both from precipitation from solution and from in-situ alteration of the glass itself. It is this clay that undergoes exfoliation as water drips from the glass. A comparison is made between the results of the parametric experiments with those of static leach tests. In the static tests the rates of release become progressively reduced through 39 weeks while, in contrast, they remain relatively constant in the parametric experiments for at least 300 weeks. This differing behavior may be attributable to the dripping water environment where fresh water is periodically added and where evaporation can occur

  15. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH{sub 4} + H{sub 2}O {yields} 3H{sub 2}O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m{sup 3}{sub N}/h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  16. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH 4 + H 2 O → 3H 2 O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m 3 N /h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  17. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  18. Single well surfactant test to evaluate surfactant floods using multi tracer method

    Science.gov (United States)

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  19. 77 FR 8865 - Recent Postings of Broadly Applicable Alternative Test Methods

    Science.gov (United States)

    2012-02-15

    ... Applicable Alternative Test Methods AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the broadly applicable alternative test method approval decisions... INFORMATION CONTACT: An electronic copy of each alternative test method approval document is available on the...

  20. Earthworm cast production as a new behavioural biomarker for toxicity testing

    Energy Technology Data Exchange (ETDEWEB)

    Capowiez, Yvan, E-mail: capowiez@avignon.inra.f [INRA, UR1115 ' Plantes et Systemes Horticoles' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Dittbrenner, Nils [INRA, UR1115 ' Plantes et Systemes Horticoles' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Animal Physiological Ecology, University of Tuebingen, Konrad-Adenauer-Str. 20, D-72072 Tuebingen (Germany); Rault, Magali [UAPV, UMR406 ' Abeilles et Environnement' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France); Triebskorn, Rita [Animal Physiological Ecology, University of Tuebingen, Konrad-Adenauer-Str. 20, D-72072 Tuebingen (Germany); Hedde, Mickael [INRA, UR251 ' PESSAC' , RD10, 78026 Versailles Cedex (France); Mazzia, Christophe [UAPV, UMR406 ' Abeilles et Environnement' , Domaine Saint Paul, 84914 Avignon Cedex 09 (France)

    2010-02-15

    There is currently a lack of ecotoxicity tests adapted to earthworm species of higher ecological relevance and whose endpoints could be directly related to their ecological role in the soil. We propose a new and relatively simple ecotoxicity test based on the estimation of cast production (CP) by Lumbricus terrestris under laboratory conditions. CP was found to be linearly correlated to earthworm biomass and to be greatly influenced by soil water content. Azinphos-methyl had no effect on CP at all the concentrations tested. Significant decreases were observed at the normal application rate for other pesticides with (imidacloprid, carbaryl, methomyl) or without (ethyl-parathion and chlorpyrifos-ethyl) a clear concentration-effect response. For the highest concentration tested, reduction in CP varied between 35 and 67%. CP is straightforward and rapidly measured and ecologically meaningful. We thus believe it to be of great use as an endpoint in ecotoxicity testing. - Cast production of Lumbricus terrestris is affected by pesticides under laboratory conditions.

  1. Earthworm cast production as a new behavioural biomarker for toxicity testing

    International Nuclear Information System (INIS)

    Capowiez, Yvan; Dittbrenner, Nils; Rault, Magali; Triebskorn, Rita; Hedde, Mickael; Mazzia, Christophe

    2010-01-01

    There is currently a lack of ecotoxicity tests adapted to earthworm species of higher ecological relevance and whose endpoints could be directly related to their ecological role in the soil. We propose a new and relatively simple ecotoxicity test based on the estimation of cast production (CP) by Lumbricus terrestris under laboratory conditions. CP was found to be linearly correlated to earthworm biomass and to be greatly influenced by soil water content. Azinphos-methyl had no effect on CP at all the concentrations tested. Significant decreases were observed at the normal application rate for other pesticides with (imidacloprid, carbaryl, methomyl) or without (ethyl-parathion and chlorpyrifos-ethyl) a clear concentration-effect response. For the highest concentration tested, reduction in CP varied between 35 and 67%. CP is straightforward and rapidly measured and ecologically meaningful. We thus believe it to be of great use as an endpoint in ecotoxicity testing. - Cast production of Lumbricus terrestris is affected by pesticides under laboratory conditions.

  2. Testing knowledge of whole English collocations available for use in written production

    DEFF Research Database (Denmark)

    Revier, Robert Lee

    2014-01-01

    Testing knowledge of whole English collocations available for use in written production: Developing tests for use with intermediate and advanced Danish learners (dansk resume nedenfor) The present foreign language acquisition research derives its impetus from four assumptions regarding knowledge...... of English collocations. These are: (a) collocation knowledge can be conceptualized as an independent knowledge construct, (b) collocations are lexical items in their own right, (c) testing of collocation knowledge should also target knowledge of whole collocations, and (d) the learning burden of a whole...... the development of Danish EFL learners’ productive knowledge of whole English collocations. Five empirical studies were designed to generate information that would shed light on the reliability and validity of the CONTRIX as a measure of collocation knowledge available for use in written production. Study 1...

  3. A Hierarchical Approach Using Machine Learning Methods in Solar Photovoltaic Energy Production Forecasting

    Directory of Open Access Journals (Sweden)

    Zhaoxuan Li

    2016-01-01

    Full Text Available We evaluate and compare two common methods, artificial neural networks (ANN and support vector regression (SVR, for predicting energy productions from a solar photovoltaic (PV system in Florida 15 min, 1 h and 24 h ahead of time. A hierarchical approach is proposed based on the machine learning algorithms tested. The production data used in this work corresponds to 15 min averaged power measurements collected from 2014. The accuracy of the model is determined using computing error statistics such as mean bias error (MBE, mean absolute error (MAE, root mean square error (RMSE, relative MBE (rMBE, mean percentage error (MPE and relative RMSE (rRMSE. This work provides findings on how forecasts from individual inverters will improve the total solar power generation forecast of the PV system.

  4. 46 CFR 54.20-5 - Welding qualification tests and production testing (modifies UW-26, UW-28, UW-29, UW-47, and UW-48).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Welding qualification tests and production testing... OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Fabrication by Welding § 54.20-5 Welding qualification tests and production testing (modifies UW-26, UW-28, UW-29, UW-47, and UW-48). (a...

  5. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  6. Calculation of isotopic mass and energy production by a matrix operator method

    International Nuclear Information System (INIS)

    Lee, C.E.

    1976-08-01

    The Volterra method of the multiplicative integral is used to determine the isotopic density, mass, and energy production in linear systems. The solution method, assumptions, and limitations are discussed. The method allows a rapid accurate calculation of the change in isotopic density, mass, and energy production independent of the magnitude of the time steps, production or decay rates, or flux levels

  7. Grasping devices and methods in automated production processes

    DEFF Research Database (Denmark)

    Fantoni, Gualtiero; Santochi, Marco; Dini, Gino

    2014-01-01

    assembly to disassembly, from aerospace to food industry, from textile to logistics) are discussed. Finally, the most recent research is reviewed in order to introduce the new trends in grasping. They provide an outlook on the future of both grippers and robotic hands in automated production processes. (C......In automated production processes grasping devices and methods play a crucial role in the handling of many parts, components and products. This keynote paper starts with a classification of grasping phases, describes how different principles are adopted at different scales in different applications...

  8. 46 CFR 159.007-11 - Production inspections and tests: Yearly report.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Yearly report. 159.007-11 Section 159.007-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production...

  9. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  10. Changeability of consumer preferences concerning the methods of fruit production

    Directory of Open Access Journals (Sweden)

    Eugenia Czernyszewicz

    2009-01-01

    Full Text Available The purpose of the paper was to establish and compare consumer preferences concerning the methods of fruit production (traditional or organic ones in the years 2001, 2003 and 2006 and the relations between the preferences and the socio-economic and demographic features of the consumers. The analysis was conducted on the basis of the data from surveys carried out among the inhabitants of Lublin. Results of those surveys point out that certain features of the consumers such as the sex, incomes and the family type significantly differentiated preferences concerning the method of fruit production. Increased incomes were connected with greater acceptance of the organic method, and their decrease was related to greater frequency of indicating the conventional method. Interest in the method of production, while buying the fruit was significantly higher among men than among women. Declaring the willingness to pay more for organic fruit was also correlated with the consumers’ sex. Besides, in 2006 it was not too strongly related to the incomes of the respondents. In the years 2001 and 2006 changeability of preferences con-cerning the willingness to pay a higher price for organic fruit and no change in the interest in the technology of fruit production while purchasing the fruit were shown.

  11. The bases for optimisation of scheduled repairs and tests of safety systems to improve the NPP productive efficiency

    International Nuclear Information System (INIS)

    Bilej, D.V.; Vasil'chenko, S.V.; Vlasenko, N.I.; Vasil'chenko, V.N.; Skalozubov, V.I.

    2004-01-01

    In the frames of risk-informed approaches the paper proposed the theoretical bases for methods of optimisation of scheduled repairs and tests of safety systems at nuclear power plants. The optimisation criterion is the objective risk function minimising. This function depends on the scheduled repairs/tests periodicity and the allowed time to bring the system channel to a state of non-operability. The main optimisation direct is to reduce the repair time with the purpose of enhancement of productive efficiency

  12. Prospects for the methods of radionuclide production

    International Nuclear Information System (INIS)

    Karamyan, S.A.; Dmitriev, S.N.

    2014-01-01

    Methods of radionuclide production for the nuclear-medicine purposes are described. In a budget approach, the application of low-energy accelerators is especially advantageous. Intense flux of bremsstrahlung at electron accelerators or high-current cyclotron beams of alpha particles must supply a great yield for many isotopes. The choice of a target material and of the projectile energy provides enough variation for concrete species formation. The innovating procedures are here proposed for optimizing of methods, for instance, application of the noble-gas target for production and transport of activities. The known and new variants of the 'generator' scheme are discussed. Many isotopes are listed as promising in the context of the therapeutic and theragnostic applications. Among them are isotopes/isomers emitting soft radiation for the selective and careful body treatment, also the positron emitters for PET, and the halogen and alkali-metal species convenient for chemical separation.

  13. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    El-Bordany Ayman; Yun, Won Young

    2014-01-01

    It reads inputs, computes new states, and updates output for each scan cycle. Korea Nuclear Instrumentation and Control System (KNICS) has recently developed a fully digitalized Reactor Protection System (RPS) based on PLD. As a digital system, this RPS is equipped with a dedicated software. The Reliability of this software is crucial to NPPs safety where its malfunction may cause irreversible consequences and affect the whole system as a Common Cause Failure (CCF). To guarantee the reliability of the whole system, the reliability of this software needs to be quantified. There are three representative methods for software reliability quantification, namely the Verification and Validation (V and V) quality-based method, the Software Reliability Growth Model (SRGM), and the test-based method. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values

  14. Moisture distribution in sludges based on different testing methods

    Institute of Scientific and Technical Information of China (English)

    Wenyi Deng; Xiaodong Li; Jianhua Yan; Fei Wang; Yong Chi; Kefa Cen

    2011-01-01

    Moisture distributions in municipal sewage sludge, printing and dyeing sludge and paper mill sludge were experimentally studied based on four different methods, i.e., drying test, thermogravimetric-differential thermal analysis (TG-DTA) test, thermogravimetricdifferential scanning calorimetry (TG-DSC) test and water activity test. The results indicated that the moistures in the mechanically dewatered sludges were interstitial water, surface water and bound water. The interstitial water accounted for more than 50% wet basis (wb) of the total moisture content. The bond strength of sludge moisture increased with decreasing moisture content, especially when the moisture content was lower than 50% wb. Furthermore, the comparison among the four different testing methods was presented.The drying test was advantaged by its ability to quantify free water, interstitial water, surface water and bound water; while TG-DSC test, TG-DTA test and water activity test were capable of determining the bond strength of moisture in sludge. It was found that the results from TG-DSC and TG-DTA test are more persuasive than water activity test.

  15. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  16. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  17. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  18. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    Science.gov (United States)

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  19. An Experimental Test of a Biodynamic Method of Weed Suppression: The Biodynamic Seed Peppers

    Directory of Open Access Journals (Sweden)

    Bruce Kenneth Kirchoff

    2016-04-01

    Full Text Available An experimental test of a biodynamic agriculture method of weed suppression was carried out in growth chambers to establish the feasibility of the method as a preliminary to field trials. Four generations of Brassica rapa plants were used in a randomized block design. Treated flats received ashed seeds prepared according to biodynamic indications. Seed weight and counts were measured at the end of each generation, and germination of the control and experimental seed was investigated at the end of generation four. The biodynamic seed peppers, created and applied as described here, had no effect on seed production or viability, and did not effectively inhibit reproduction of the targeted species over the course of four consecutive treatments.

  20. Mixture toxicity of wood preservative products in the fish embryo toxicity test.

    Science.gov (United States)

    Coors, Anja; Dobrick, Jan; Möder, Monika; Kehrer, Anja

    2012-06-01

    Wood preservative products are used globally to protect wood from fungal decay and insects. We investigated the aquatic toxicity of five commercial wood preservative products, the biocidal active substances and some formulation additives contained therein, as well as six generic binary mixtures of the active substances in the fish embryo toxicity test (FET). Median lethal concentrations (LC50) of the single substances, the mixtures, and the products were estimated from concentration-response curves and corrected for concentrations measured in the test medium. The comparison of the experimentally observed mixture toxicity with the toxicity predicted by the concept of concentration addition (CA) showed less than twofold deviation for all binary mixtures of the active substances and for three of the biocidal products. A more than 60-fold underestimation of the toxicity of the fourth product by the CA prediction was detected and could be explained fully by the toxicity of one formulation additive, which had been labeled as a hazardous substance. The reason for the 4.6-fold underestimation of toxicity of the fifth product could not be explained unambiguously. Overall, the FET was found to be a suitable screening tool to verify whether the toxicity of formulated wood preservatives can reliably be predicted by CA. Applied as a quick and simple nonanimal screening test, the FET may support approaches of applying component-based mixture toxicity predictions within the environmental risk assessment of biocidal products, which is required according to European regulations. Copyright © 2012 SETAC.