  1. Power Product Equipment Technician: Outboard-Engine Systems and Service. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Hilley, Robert

    This curriculum guide contains teacher and student materials for a course on outboard-engine boat systems and service for power product equipment technician occupations. The course contains the following four units of instruction: (1) Outboard-Engine Design and Identification; (2) Operation and Service of Engine-Support Systems; (3) Operation and…

  2. Power Product Equipment Technician: Outboard-Engine Boat Systems. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Hilley, Robert

    This curriculum guide contains teacher and student materials for a course on outboard-engine boat systems for power product equipment technician occupations. The course contains the following three units of instruction: (1) Orientation to Outboard-Engine Boat Systems and Rigging; (2) Trailers and Safe Towing and Boat Operation; and (3) Seasonal…

  3. Recovery Act: Training Program Development for Commercial Building Equipment Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Leah Glameyer

    2012-07-12

    The overall goal of this project has been to develop curricula, certification requirements, and accreditation standards for training on energy efficient practices and technologies for commercial building technicians. These training products will advance industry expertise towards net-zero energy commercial building goals and will result in a substantial reduction in energy use. The ultimate objective is to develop a workforce that can bring existing commercial buildings up to their energy performance potential and ensure that new commercial buildings do not fall below their expected optimal level of performance. Commercial building equipment technicians participating in this training program will learn how to best operate commercial buildings to ensure they reach their expected energy performance level. The training is a combination of classroom, online and on-site lessons. The Texas Engineering Extension Service (TEEX) developed curricula using subject matter and adult learning experts to ensure the training meets certification requirements and accreditation standards for training these technicians. The training targets a specific climate zone to meets the needs, specialized expertise, and perspectives of the commercial building equipment technicians in that zone. The combination of efficient operations and advanced design will improve the internal built environment of a commercial building by increasing comfort and safety, while reducing energy use and environmental impact. Properly trained technicians will ensure equipment operates at design specifications. A second impact is a more highly trained workforce that is better equipped to obtain employment. Organizations that contributed to the development of the training program include TEEX and the Texas Engineering Experiment Station (TEES) (both members of The Texas A&M University System). TEES is also a member of the Building Commissioning Association. This report includes a description of the project

  4. Outdoor Power Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5111.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Outdoor Power Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) supervise, train and coach apprentices; (2) service, maintain, repair and rebuild outdoor power equipment and outdoor power equipment accessories; (3) communicate clearly with customers, staff, suppliers, as required;…

  5. Heavy Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 1912

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Heavy Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) diagnose repair, and maintain by skills and knowledge gained through training and experience any of the working parts of diesel engines as well as the various components of mobile industrial equipment; (2) use, competently,…

  6. Radiologic Equipment and Technicians according to the Distribution of the Population

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Choi, Jun Gu

    2009-01-01

    The purpose of this paper is to provide basic data in order to systematize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipment and technicians according to the distribution of the population. We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without 'Gu' administrative units in 2008. 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipment to radiologic technicians is 2.6 to 1. There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  7. Agricultural Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 3212

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Agricultural Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) repair, diagnose and maintain by skill and knowledge gained through training and experience any of the working parts of diesel engines as well as the various components of mobile farm machinery; (2) use, competently,…

  8. Section 608 Technician Certification

    Science.gov (United States)

    Certifications for technicians who maintain, service, repair, or dispose of equipment that could release ozone depleting refrigerants or, after January 1, 2018, substitute refrigerants into the atmosphere.

  9. Technicians and Shop Owners

    Science.gov (United States)

    Overview page provides information for shops and technicians that repair or service motor vehicle air-conditioning systems, including information on proper training, approved equipment, and regulatory practices.

  10. Diesel Engine Technician

    Science.gov (United States)

    Tech Directions, 2010

    2010-01-01

    Diesel engine technicians maintain and repair the engines that power transportation equipment such as heavy trucks, trains, buses, and locomotives. Some technicians work mainly on farm machines, ships, compressors, and pumps. Others work mostly on construction equipment such as cranes, power shovels, bulldozers, and paving machines. This article…

  11. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 2. Equipment, Safe Driving Practices, Legal Aspects, Controlling the Situation, Action Evaluation Conference. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the second in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains five sections that cover the following course content: ambulance equipment, safe driving practices for emergency vehicle drivers, legal aspects of the EMT's job, how to maintain control at an accident scene…

  12. Welding Technician

    Science.gov (United States)

    Smith, Ken

    2009-01-01

    About 95% of all manufactured goods in this country are welded or joined in some way. These welded products range in nature from bicycle handlebars and skyscrapers to bridges and race cars. The author discusses what students need to know about careers for welding technicians--wages, responsibilities, skills needed, career advancement…

  13. The correlation between the use of personal protective equipment and level wild-type p53 of dental technicians in Surabaya

    Directory of Open Access Journals (Sweden)

    Puspa Dila Rohmaniar

    2017-03-01

    Full Text Available Background: Exposure of metals among dental technicians that come from the working environment can lead to the formation reactive oxygen species (ROS. ROS can cause mutations in the p53 gene (p53. The mutation is transversion mutation GuanineThymine. p53 mutations can lead to low expression of the wild-type p53 protein (p53. Wild-type p53 involved in many biological processes such as regulation of genes involved in cell cycle, cell growth after DNA damage, and apoptosis. However, exposure to metals among dental technicians can be prevented through the use of personal protective equipment (PPE during work. Purpose: The purpose of this study was to analyze the correlation between the use of personal protective equipment to wild-type p53 protein levels among dental technicians in Surabaya. Method: This study was observational analytic with cross sectional approach. 40 samples were taken by random sampling. Data were retrieved through interviews and observations. Wild-type p53 was analyzed from saliva with indirect ELISA method. Analysis of data used Kolmogorov Smirnov normality test and a Pearson correlation test. Value significance was p<0.05 (95% confidence level. Result: There was a significant association between the use of personal protective equipment with wild-type p53 levels with p=0.002 Conclusion: The use PPE properly is positively correlated with the wild-type p53 protein levels of dental technicians in Surabaya.

  14. Oil and gas products and energy equipment

    International Nuclear Information System (INIS)

    1996-01-01

    The planned activities of the Canadian oil and gas products and energy equipment industry for 1996-1997, were presented. The sector is made up of approximately 1500 small and medium sized enterprises. The Canadian oil field manufacturing and servicing industry holds only a small 2.5% share of the world export market, but it is recognized internationally as one of the leading suppliers of advanced petroleum equipment. Their exports include specialized equipment for extracting oil sands, gathering and treatment facilities for sour gas, underbalanced drilling technologies, equipment for wells experiencing declining production rates, top motor drives, winter drilling rigs, and horizontal drilling technologies. They also offer petroleum industry software products. Most exploration and production equipment sold abroad by Canadian firms is manufactured in Canada, but there is an increasing trend toward manufacturing in the country of operation. 2 tabs

  15. You're a What?: Tower Technician

    Science.gov (United States)

    Vilorio, Dennis

    2012-01-01

    In this article, the author talks about the role and functions of a tower technician. A tower technician climbs up the face of telecommunications towers to remove, install, test, maintain, and repair a variety of equipment--from antennas to light bulbs. Tower technicians also build shelters and radiofrequency shields for electronic equipment, lay…

  16. Process and equipment design optimising product properties and attributes

    NARCIS (Netherlands)

    Bongers, P.M.M.; Thullie, J.

    2009-01-01

    Classically, when products have been developed at the bench, process engineers will search for equipment to manufacture the product at large scale. More than often, this search is constraint to the existing equipment base, or a catalog search for standard equipment. It is then not surprising, that

  17. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    International Nuclear Information System (INIS)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-01-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given

  18. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    Science.gov (United States)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-12-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given.

  19. Cedrela odorata L. PRODUCTION IN A RAW SAWDUST SUBSTRATE IN TECHNICIAN SYSTEM AT TECPAN DE GALEANA, GUERRERO, MEXICO

    Directory of Open Access Journals (Sweden)

    José Justo Mateo-Sánchez

    2011-01-01

    Full Text Available Nursery high quality plants production by using expensive commercial substrates (peat moss, perlite, vermiculite decreases profits; this is the main reason to search alternative production substrates. Pine sawdust is a sub product of forestry industry cheap and available in forest areas. In recent years it has been used as a substrateproviding good results. In this study it was evaluated the effect of different sawdust mixtures on Cedrela odorata L. plant growth in a technician system in forest nursery under shade cloth covered. A completely randomized experimental design was used with eleven substrate components combinations (sawdust + peat moss-perlite-vermiculite mixtures ranging from 0% to 100% each. After three and a half months morphological variables were measured so as some quality indexes in seedlings. The largest diameter was obtained by the mixture of 70% sawdust + 30% peat moss mix-vermiculite-perlite. The highest in height by using the mixture 80% sawdust + 20% peat moss - vermiculite – perlite mixture. The highest leaves dry weight corresponded to 90 % sawdust + 10% peat moss-vermiculite-perlite mixture. However the highest root weight and total dry weight values occurred in 60% sawdust + 40% peat moss – perlite - vermiculite mixture. As for the height-diameter ratio (slenderness index, the best value is obtained a mixture of 80% sawdust + 20% peat moss, perlite, vermiculite. According to Dickson Quality Index (DQI, used to predict the plant field surviving, the highest value was obtained for the 60% sawdust + 40% peat moss-perlite-vermiculite mixture.

  20. MODERN PROCESSES AND EQUIPMENT FOR BEER PRODUCTION

    Directory of Open Access Journals (Sweden)

    Yu. I. Sidorov

    2013-04-01

    Full Text Available Modern progress trends of processes of brewing and fermenters for their realization are considered. It is rotined that the today most widespread method of production are speed-up processes on the method of Nathan in one technological stage in one vehicle –cylinder-conical tank — CCT. The next stage of development must be passing to the continuous methods, however these, known enough methods, so far did not find realization. The second directions of development of brewing is distribution of minibrewerys, including restaurant complexes. The basic stimulus of development of this direction is possibility of receipt of the so-called «living» beer — the high-quality unfiltered product, however today large competition make mass productions which mastered the technique of production of «living» beer at industrial level.

  1. Career Directions--Electronics Technician

    Science.gov (United States)

    Tech Directions, 2012

    2012-01-01

    Electronics technicians (ETs) work with electronics engineers to set up and maintain complicated electronics equipment that many of today's businesses rely on. The field is varied. An ET might service the industrial controls on a factory floor. Or repair missile control systems for the government. Or an ET could specialize in cars and trucks,…

  2. Cost Accounting: Production and Equipment Services.

    Science.gov (United States)

    Schmid, William T.

    Cost accounting for audiovisual productions should include direct costs, and, in some cases, the media administrator may have to calculate a per-hour surcharge for general operating overhead as well. Such procedures enable the administrator to determine cost effectiveness, to control cost overruns, and to generate more staff efficiency. Cost…

  3. Equipment, components and production of x-ray

    International Nuclear Information System (INIS)

    Idris Besar

    2004-01-01

    The contents of this chapter are follows - Equipment, Components and Production of x-Ray: x-ray system, generator, control panel. x-ray tube, cathode, anode, envelope, housing, collimator, other components, x-ray production, Bremsstrahlung x-ray, characteristic x-ray, heat production

  4. Forensic Science Technician

    Science.gov (United States)

    Tech Directions, 2010

    2010-01-01

    Forensic science technicians, also called crime laboratory technicians or police science technicians, help solve crimes. They examine and identify physical evidence to reconstruct a crime scene. This article discusses everything students need to know about careers for forensic science technicians--wages, responsibilities, skills needed, career…

  5. THE DIFFERENTS FACES OF TRUST IN THE TOBACCO PRODUCTION IN RIO GRANDE DO SUL, BRAZIL: RELATIONS BETWEEN FARMERS AND THE FIELD TECHNICIANS

    Directory of Open Access Journals (Sweden)

    Carlise Schneider Rudnicki

    2014-02-01

    Full Text Available In region of Vale do Rio Pardo, situated in Rio Grande do Sul, Brazil, the production of tobacco is an important source of income, especially for family farmers. The discussion around tobacco production in the academic researches and society’s debate involves: the problems that smoking causes in human health and the same time, the role of farmers have been developed in the productive chain. In view of this, the aim of this article was to understand the trust relation between farms and the field technicians in the Vale do Rio Pardo region and the south side area of the Rio Grande do Sul, Brazil. 142 interviews have been accomplished with families that are producing tobacco, using a semi-structured form (qualitative and quantitative questions. The Likert scale, field diaries and observations were used as search tools. When farmers have been questioned about trust in agricultural technicians (using Likert scale, the answers were similar in the three cities: the southern Rio Grande do Sul, in Dom Feliciano, confidence is 69.7%; in the Vale do Rio Pardo, Rio Pardo and Santa Cruz do Sul, respectively, confidence is 63.3% and 64.6%, according to levels between “agree” and “disagree totally”. Besides, in this context, there is direct relation between trust in the field technicians and integration of tobacco. The informal relation between farms and the field technicians has been changed by formal contracts. Nevertheless, informality was relevant, specifically because it may help to understand how the trust emerges in friendships and family relations.

  6. From product to service orientation in the maritime equipment industry

    DEFF Research Database (Denmark)

    Matzen, Detlef; McAloone, Timothy Charles

    2008-01-01

    of their products in operation. In this paper we present a case study of a shipping equipment manufacturer that is currently shifting business focus from manufacturing towards services delivery. Using a modelling scheme to differentiate and categorise different development tasks within the frame of business......In the shipping industry, operational performance of ships and their equipment is crucial to business. Suppliers of machinery and equipment are aware of this situation and see business development potential in setting up service systems that are dedicated to ensuring the performance...... development towards service oriented business, the case delivers insights into the broader context and product related parameters influencing the options and requirements for service system development....

  7. Practical digital electronics for technicians

    CERN Document Server

    Kimber, Will

    2013-01-01

    Practical Digital Electronics for Technicians covers topics on analog and digital signals, logic gates, combinational logic, and Karnaugh mapping. The book discusses the characteristics and types of logic families; sequential systems including latch, bistable circuits, counters and shift registers; Schmitt triggers and multivibrators; and MSI combinational logic systems. Display devices, including LED, LCD and dot matrix display; analog and digital conversion; and examples of and equipment for digital fault finding are also considered. The book concludes by providing answers to the questions

  8. Concrete pedestals for high-performance semiconductor production equipment

    Science.gov (United States)

    Vogen, Wayne; Franklin, Craig L.; Morneault, Joseph

    1999-09-01

    Concrete pedestals have many vibration and stiffness characteristics that make them a superior choice for sensitive semiconductor production equipment including scanners, scanning electron microscopes, focused ion beam millers and optical inspection equipment. Among the advantages of concrete pedestals are high inherent damping, monolithic construction that eliminates low stiffness joints common in steep pedestals, ability to reuse and ease of installation. Steel pedestals that have plates attached to the top of the frame are easily excited by acoustic excitation, especially in the range from 50 Hertz to 400 Hertz. Concrete pedestals do not suffer from this phenomenon because of the high mass and damping of the top surface.

  9. Aviation Support Equipment Technician (ASE 3 & 2 and ASM 3 & 2). Volume 1, Basics. Rate Training Manual and Nonresident Career Course.

    Science.gov (United States)

    Grant, Jesse R.; And Others

    This Rate Training Manual and Nonresident Career Course (RTM/NRCC) form a self-study package that will enable aviation support equipment personnel to help themselves fulfill the requirements for advancement. Designed for individual study and not formal classroom instruction, the RTM provides subject matter that relates directly to the occupational…

  10. Modeling Manpower and Equipment Productivity in Tall Building Construction Projects

    Science.gov (United States)

    Mudumbai Krishnaswamy, Parthasarathy; Rajiah, Murugasan; Vasan, Ramya

    2017-12-01

    Tall building construction projects involve two critical resources of manpower and equipment. Their usage, however, widely varies due to several factors affecting their productivity. Currently, no systematic study for estimating and increasing their productivity is available. What is prevalent is the use of empirical data, experience of similar projects and assumptions. As tall building projects are here to stay and increase, to meet the emerging demands in ever shrinking urban spaces, it is imperative to explore ways and means of scientific productivity models for basic construction activities: concrete, reinforcement, formwork, block work and plastering for the input of specific resources in a mixed environment of manpower and equipment usage. Data pertaining to 72 tall building projects in India were collected and analyzed. Then, suitable productivity estimation models were developed using multiple linear regression analysis and validated using independent field data. It is hoped that the models developed in the study will be useful for quantity surveyors, cost engineers and project managers to estimate productivity of resources in tall building projects.

  11. Inventory Management Strategies For Productivity Improvement In Equipment Manufacturing Firms

    Directory of Open Access Journals (Sweden)

    T.T Amachree

    2017-08-01

    Full Text Available This study examined and developed Inventory Management Strategies IMS which could be creatively employed for Productivity Improvement in Equipment Firms PIEMF Equipment manufacturing projects suffer from declining productivity and inability to effectively satisfy customized order batch quantity within schedules budgeted cost and quality specifications due to lack of robust and well defined IMS as well as none code classification of vast number of inventory item. Survey and expost-facto research designs were adopted on the four identified IMS in three EMF. The method used for primary data collection and measurement on four IMS and inventory management parameters was questionnaire modelled into likert five point scale from the target respondents being experts in the subject matter. The secondary data was obtained from the computerised inventory status file of the three equipment manufacturing firms. The methods of primary data analysis and test of research used were Pearsons product moment correlation coefficient and oneway. Analysis of variance ANOVA computer software via Statistical Program for Social Science SPSS version 17 ABC analysis and classification of materials was used for code categorization of secondary data also with the aid of Microsoft excel. The results of the analyses highlighted and isolated A class of inventory items which are 137 out of 543 for Siemens Nig. Ltd 154 out of 551 for Dresser-Rand Nig. Ltd and 162 of 551 for Nigerian Engineering Works Ltd. The results of Pearson product moment correlation analysis and test of research hypotheses indicate that Materials Requirements Planning MRP followed by Supply Chain Management SCM are the most significant IMS as they correlate strongly with PIEMF. The study recommends IMS adoption by code classification of materials in which MRP or SCM could be deployed for management of A class of inventories while classical IMS could be used for management B and C classes of inventory items.

  12. A System Approach to Navy Medical Education and Training. Appendix 15. Biotronics Technicians.

    Science.gov (United States)

    1974-08-31

    curricula based upon job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third...Therapy Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical Equipment Repair Technician... WET COMPRESSES/SOAKS/PACKS 24 ICONTROL BLEEDING BY PRESSURE DRESSING 25 1APPLY/CHANGE BANDAGES, E.G. ROLLER, TRIANGULAR, KURLEX GO TO RIGHT HAND PAGE

  13. Electric Vehicle Technician

    Science.gov (United States)

    Moore, Pam

    2011-01-01

    With President Obama's goal to have one million electric vehicles (EV) on the road by 2015, the electric vehicle technician should have a promising and busy future. "The job force in the car industry is ramping up for a revitalized green car industry," according to Greencareersguide.com. An electric vehicle technician will safely troubleshoot and…

  14. Career Directions: HVACR Technician

    Science.gov (United States)

    Moore, Pam

    2005-01-01

    Heating/ventilation/air conditioning/refrigeration (HVACR) technicians (also known as "heating and cooling technicians") are the people who install, maintain, test and repair the machines that control temperature, circulation, moisture and purity of air in residential, commercial and industrial buildings. These systems consist of a variety of…

  15. Fiber Optics Technician. Curriculum Research Project. Final Report.

    Science.gov (United States)

    Whittington, Herschel K.

    A study examined the role of technicians in the fiber optics industry and determined those elements that should be included in a comprehensive curriculum to prepare fiber optics technicians for employment in the Texas labor market. First the current literature, including the ERIC database and equipment manufacturers' journals were reviewed. After…

  16. COATING OF FOOD PRODUCTS : BATTER AND BREADING TECHNIQUES AND EQUIPMENTS

    Directory of Open Access Journals (Sweden)

    Figen KAYMAK ERTEN

    2005-01-01

    Full Text Available The coating process of food products with various mixtures prior to frying is a common application in kitchens whereas it still requires much investigation in technological area. In this study, batter and breading technology used in coating of foods is reviewed. The coating process was defined, and the function of predusting, battering and breading, the general composition of batter and breading mixtures and the functions of the ingradients were explained. In the coating application, the most important problem known as adhesion and the effects of it on the efficiency and cost were investigated. Batter and breading processing equipments used in the industry and the process lines were reviewed, and the problems, new designs and the latest patents relating them were discussed. New coating systems known as tumbling and fluidization were investigated and compared with other systems.

  17. Analysis of total productive maintenance (TPM) implementation using overall equipment effectiveness (OEE) and six big losses: A case study

    Science.gov (United States)

    Martomo, Zenithia Intan; Laksono, Pringgo Widyo

    2018-02-01

    In improving the productivity of the machine, the management of the decision or maintenance policy must be appropriate. In Spinning II unit at PT Apac Inti Corpora, there are 124 ring frame machines that often have breakdown and cause a high downtime so that the production target is not achieved, so this research was conducted on the ring frame machine. This study aims to measure the value of equipment effectiveness, find the root cause of the problem and provide suggestions for improvement. This research begins with measuring the achievement of overall equipment effectiveness (OEE) value, then identifying the six big losses that occur. The results show that the average value of OEE in the ring frame machine is 79.96%, the effectiveness value is quite low because the standard of OEE value for world class company ideally is 85%. The biggest factor that influences the low value of OEE is performance rate with percentage factor six big losses at reduced speed losses of 17.303% of all time loss. Proposed improvement actions are the application of autonomous maintenance, providing training for operators and maintenance technicians and supervising operators in the workplace.

  18. Sustainable Product: Personal Protective Equipment Manufactured with Green Plastic

    Directory of Open Access Journals (Sweden)

    Hamilton Aparecido Boa Vista

    2015-04-01

    Full Text Available This study analyzed the case of manufacturing of Personal Protective Equipment (PPE using as raw material biopolymers produced from ethanol from sugar cane, known as green polypropylene, produced since 2008 by BRASKEM. This article studied the PPE for the employee’s head protection, named helmet by NR 6, which is used in situations of exposure to weather and work scenarios in places where there is risk of impact from falling or projecting objects, burns, electric shock, and solar radiation. The MSA, green helmet manufacturer, made an inventory of greenhouse gas emissions into the atmosphere by comparing the two manufacturing processes of the helmet shell, covering the January 1 to December 31, 2011 period. It concluded that the sustainable helmet (green polyethylene and pigments robs 231g of CO2 from the atmosphere per produced unit, while the helmet’s production with traditional raw materials (polyethylene and petrochemical pigments found that, for each unit produced, 1029g of CO2 are emitted into the atmosphere. The study showed that substitution of raw materials has led to reduction in the impact generated in the helmets’ production.

  19. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  20. Electronics for technicians

    CERN Document Server

    Crane, P W

    2013-01-01

    Electronics for Technicians covers the basic fundamentals of electronics, including the operation of devices and circuits. The book is meant to help the technician to obtain numerical answers to actual circuit problems. This volume consists of seven chapters, the first of which introduces the reader to the basic rules for circuits containing resistive and reactive elements. Charge and discharge of a capacitor through a resistor is discussed, along with charge and discharge of an inductance through a resistance, application of sinusoidal voltages to simple networks, and series and parallel LCR

  1. Equipment for production of hydrogel by sol-gel method

    International Nuclear Information System (INIS)

    Urbanek, V.

    1975-01-01

    The method of uranyl gel preparation is described by the sol-gel process of the internal gelation type. A laboratory-scale equipment with an output of 1.5 kg of gel per hour was built at the Nuclear Research Institute, Rez; the diameter of the microspheres produced may vary between 0.5 and 4.0 mm. The reliability of the equipment was verified by producing several tens of kilograms of uranyl gels and of gels based on other non-nuclear materials. (author)

  2. [Role of the technician in a brachytherapy department].

    Science.gov (United States)

    Bélot-Cheval, V; Lemoine, L; Cuisinier, C; Gensse, M-C; Lasbareilles, O

    2013-04-01

    The role of the technician in a brachytherapy department is essential for the cohesion of the treatment team made up of the radiation oncologist, the physicist, and the technician. He/she collaborates in the different treatment steps such as taking care of the patients, training of the professionals and research studies in collaboration with the team. He participates in all steps of the treatment such as preparation, technician's consultation, catheters/templates and radioactives sources implant, dose distribution analysis and treatment. He looks after the management of planning, radioactive sources and chemist's equipments. He takes part in the training of the junior technician, and support doctors and physicists in different studies. The procedure writing and the presentation of professional practices are also part of the technician task. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  3. Improving Product Performance Through New Equipment Training (NET) Techniques

    Science.gov (United States)

    2008-12-01

    communication equipment with gloves, acquire targets while wearing helmet and protective eyewear , and stealth movement to contact the enemy and...to be utilized in the literature review. We found that the industry and academic information we retrieved was relevant and transferable to the...chapter summarized industry and academic research relevant to enhancing Marines abilities to better notice and correctly utilize Infantry Combat

  4. A novel method to determine simultaneously methane production during in vitro gas production using fully automated equipment

    NARCIS (Netherlands)

    Pellikaan, W.F.; Hendriks, W.H.; Uwimanaa, G.; Bongers, L.J.G.M.; Becker, P.M.; Cone, J.W.

    2011-01-01

    An adaptation of fully automated gas production equipment was tested for its ability to simultaneously measure methane and total gas. The simultaneous measurement of gas production and gas composition was not possible using fully automated equipment, as the bottles should be kept closed during the

  5. Efficiancy of hydrogen peroxide for cleaning production areas and equipments in the radiopharmaceutical production

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Tatyana S.; Batista, Vanessa; Gomes, Antonio; Matsuda, Margareth; Fukumori, Neuza; Araujo, Elaine B. de, E-mail: tsbaptista@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    A great challenge in the radiopharmaceuticals production is to fulfill the Good Manufacturing Practices (GMPs), involving the validation of process and of all supporting activities such as cleaning and sanitization. The increasingly strict requirements for quality assurance system, with several norms and normative resolutions has led to a constant concern with programs and cleaning validation in pharmaceutical production. The main goal of GMP is to reduce risks inherent to pharmaceutical production, that is to reduce product contamination with microorganisms and cross-contamination. The basic requirements to prevent contamination is the development and implementation of efficient cleaning programs. In the case of clean rooms for the production of injectable radiopharmaceuticals, the requirement for cleaning programs is evidently higher due to the characteristics of these areas with hot cells for radioactive materials, where sterile radiopharmaceuticals are manipulated and distributed before administration to patients just after minutes or hours of its preparation. In the Radiopharmacy Department at IPEN it was established a cleaning program for clean rooms and hot cells using a hydrogen peroxide solution (20% proxitane alfa). The objective of this work was to assess effectiveness of this cleaning agent in reducing and/or eliminating microbial load in the clean rooms and equipment to acceptable levels in accordance with the current legislation. The analysis was conducted using results of the environmental monitoring program with and settling contact plates in clean rooms after the cleaning procedures. Furthermore, it was possible to evaluate the action of the sanitizing agent on the microbial population on the surface of equipment and clean rooms. It was also evaluated the best way to accomplish the cleaning program considering the dosimetric factor in each production process, as the main concern of pharmaceutical companies is the microbiological contamination, in

  6. Efficiancy of hydrogen peroxide for cleaning production areas and equipments in the radiopharmaceutical production

    International Nuclear Information System (INIS)

    Baptista, Tatyana S.; Batista, Vanessa; Gomes, Antonio; Matsuda, Margareth; Fukumori, Neuza; Araujo, Elaine B. de

    2013-01-01

    A great challenge in the radiopharmaceuticals production is to fulfill the Good Manufacturing Practices (GMPs), involving the validation of process and of all supporting activities such as cleaning and sanitization. The increasingly strict requirements for quality assurance system, with several norms and normative resolutions has led to a constant concern with programs and cleaning validation in pharmaceutical production. The main goal of GMP is to reduce risks inherent to pharmaceutical production, that is to reduce product contamination with microorganisms and cross-contamination. The basic requirements to prevent contamination is the development and implementation of efficient cleaning programs. In the case of clean rooms for the production of injectable radiopharmaceuticals, the requirement for cleaning programs is evidently higher due to the characteristics of these areas with hot cells for radioactive materials, where sterile radiopharmaceuticals are manipulated and distributed before administration to patients just after minutes or hours of its preparation. In the Radiopharmacy Department at IPEN it was established a cleaning program for clean rooms and hot cells using a hydrogen peroxide solution (20% proxitane alfa). The objective of this work was to assess effectiveness of this cleaning agent in reducing and/or eliminating microbial load in the clean rooms and equipment to acceptable levels in accordance with the current legislation. The analysis was conducted using results of the environmental monitoring program with and settling contact plates in clean rooms after the cleaning procedures. Furthermore, it was possible to evaluate the action of the sanitizing agent on the microbial population on the surface of equipment and clean rooms. It was also evaluated the best way to accomplish the cleaning program considering the dosimetric factor in each production process, as the main concern of pharmaceutical companies is the microbiological contamination, in

  7. Designing efficient logging systems for northern hardwoods using equipment production capabilities and costs.

    Science.gov (United States)

    R.B. Gardner

    1966-01-01

    Describes a typical logging system used in the Lake and Northeastern States, discusses each step in the operation, and presents a simple method for designing and efficient logging system for such an operation. Points out that a system should always be built around the key piece of equipment, which is usually the skidder. Specific equipment types and their production...

  8. Investigating factors that influence level and dynamics of capital productivity in plants manufacturing equipment for mines

    Energy Technology Data Exchange (ETDEWEB)

    Karenov, R.S. (Karagandinskii Politekhnicheskii Institut (USSR))

    1990-10-01

    Analyzes productivity of capital in plants manufacturing equipment for underground coal mining in the USSR. Effects of the following factors are evaluated: working time, investment, mechanization of manufacturing processes, power of motors used to drive the manufacturing equipment, duration of a manufacturing cycle, cooperation degree, equipment service life. Effects of insufficient specialization of manufacturing plants and the manufacturing of mining equipment by repair shops of individual mines which should rather specialize in equipment repair and maintenance are evaluated. Analysis shows that specialization of the manufacturing plants could increase productivity of capital by 1.5-2.0 times, reduce labor consumption by 3-5 times and consumption of materials by 1.5-1.7 times. 4 refs.

  9. Development and capital investment tasks involved in the production of charge transfer equipment

    International Nuclear Information System (INIS)

    Simon, Sandor

    1983-01-01

    Stringent requirements had to be considered in the course of the production development of charge transfer equipment. The production of structures demanding extremely high endurance was based on extensive co-operation. Special alloys were needed for parts and bearings, special heat-treatment was required at certain sections for large dimensions etc. Appropriate mashine stock, assembly and test hall have been built for assembling and testing the equipment with both 440 and 100 MW.(Sz.J.)

  10. Calibration and qualification of equipment in the pharmaceutical industry: emphasis on radiopharmaceuticals production

    International Nuclear Information System (INIS)

    Melero, Laura T.U.H.; Silva, Katia S. da S.; Zanette, Camila; Araujo, Elaine B. de; Mengatti, Jair

    2011-01-01

    The calibration and qualification of equipment are listed items in RDC number 17 of 2010 which refers about the Good Manufacturing Practice (GMP) of medicaments and RDC number 63 of 2009 which refers about GMP of Radiopharmaceuticals. Both are essential requirements since they are involved in process control to attend the regulatory criteria and are a key part of the validation process. The aim of this work is presenting the importance of calibration and qualification, and the routine use of equipment and facilities in industrial scale production of radiopharmaceuticals in the IPEN/CNEN. The radiopharmacy of IPEN is a pharmaceutical industry that produces radiopharmaceuticals for diagnosis and therapy. It was the pioneer institute in production of radioisotopes and radiopharmaceuticals in Brazil. Currently, 38 products are distributed to the nuclear medicine centers, including primary radioisotopes, labeled molecules and lyophilized reagents for labeling with technetium-99m. To fulfill the GMP requirements for quality assurance of products, several factors must be considered including infrastructure, equipment and raw materials beyond, obviously, the whole production process should be controlled until the release of the final product. Therefore, the calibration and verification of equipment, instruments and other appliances used in the production and quality control should be performed. A program of calibration, qualification and requalification of equipment used in production and quality control of radiopharmaceuticals is necessary for the validation of production processes and analytical methods, and should be established for quality assurance of produced radiopharmaceuticals. (author)

  11. Calibration and qualification of equipment in the pharmaceutical industry: emphasis on radiopharmaceuticals production

    Energy Technology Data Exchange (ETDEWEB)

    Melero, Laura T.U.H.; Silva, Katia S. da S.; Zanette, Camila; Araujo, Elaine B. de; Mengatti, Jair [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The calibration and qualification of equipment are listed items in RDC number 17 of 2010 which refers about the Good Manufacturing Practice (GMP) of medicaments and RDC number 63 of 2009 which refers about GMP of Radiopharmaceuticals. Both are essential requirements since they are involved in process control to attend the regulatory criteria and are a key part of the validation process. The aim of this work is presenting the importance of calibration and qualification, and the routine use of equipment and facilities in industrial scale production of radiopharmaceuticals in the IPEN/CNEN. The radiopharmacy of IPEN is a pharmaceutical industry that produces radiopharmaceuticals for diagnosis and therapy. It was the pioneer institute in production of radioisotopes and radiopharmaceuticals in Brazil. Currently, 38 products are distributed to the nuclear medicine centers, including primary radioisotopes, labeled molecules and lyophilized reagents for labeling with technetium-99m. To fulfill the GMP requirements for quality assurance of products, several factors must be considered including infrastructure, equipment and raw materials beyond, obviously, the whole production process should be controlled until the release of the final product. Therefore, the calibration and verification of equipment, instruments and other appliances used in the production and quality control should be performed. A program of calibration, qualification and requalification of equipment used in production and quality control of radiopharmaceuticals is necessary for the validation of production processes and analytical methods, and should be established for quality assurance of produced radiopharmaceuticals. (author)

  12. Data analyst technician: an innovative role for the pharmacy technician.

    Science.gov (United States)

    Ervin, K C; Skledar, S; Hess, M M; Ryan, M

    2001-10-01

    The development of an innovative role for the pharmacy technician is described. The role of the pharmacy technician was based on a needs assessment and the expertise of the pharmacy technician selected. Initial responsibilities of the technician included chart reviews, benchmarking surveys, monthly financial impact analysis, initiative assessment, and quality improvement reporting. As the drug-use and disease-state management (DUDSM) program expanded, pharmacist activities increased, requiring the expansion of data analyst technician (DAT) duties. These new responsibilities included participation in patient assessment, data collection and interpretation, and formulary enforcement. Most recently, technicians' expanded duties include maintenance of a physician compliance profiling database, quality improvement reporting and graphing, active role in patient risk assessment and database management for adult vaccination, and support of financial impact monitoring for other institutions within the health system. This pharmacist-technician collaboration resulted a threefold increase in patient assessments completed per day. In addition, as the DUDSM program continues to expand across the health system, an increase in DAT resources from 0.5 to 1.0 full-time equivalent was obtained. The role of the DAT has increased the efficiency of the DUDSM program and has provided an innovative role for the pharmacy technician.

  13. Production Equipment and Processes for Bulk Formed Micro Components

    DEFF Research Database (Denmark)

    Paldan, Nikolas Aulin; Arentoft, Mogens; Eriksen, Rasmus Solmer

    2007-01-01

    Manufacturing techniques for production of small precise metallic parts has gained interest during recent years, an interest led by an industrial demand for components for integrated products like mobile phones, personal digital assistants (PDAs), mp3-players and in the future for spare parts...... has been developed and used to form a number of industrial micro parts in aluminium and silver, with ongoing work on forming of titanium. Manufacture of billets by cropping has been examined using a simple test rig and an automatic cropping device has been designed, manufactured and tested....... for the human body. Micro components have also found several applications within the medical, audiological and dental industry, applications that impose increased demands for biocompatible and corrosion-resistant materials and cleanness. So far these micro components have mainly been manufactured by traditional...

  14. Determining the productivity of frontal-selective excavation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Baikenzhin, A E; Ermekov, T E

    1979-01-01

    The engineering parameters of the VMF-2 frontal-selective excavation machine are given. Calculation formulae are given for determining the feed speed of the working tool relative to the difference in the motion of the arm of the working tool and the feed speed of the hydraulic jack lifter. A methodology is developed for calculating the productivity of the excavator depending on various engineering conditions, accounting for modifications in its design.

  15. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  16. Radiation Technician Scientist service

    International Nuclear Information System (INIS)

    Prieto Miranda, Enrique; Barrera Gonzalez, Gisela; Guerra Torres, Mercedes; Mora Lopez, Leonor; Altanes Valentin, Sonia; Rapado Paneque, Manuel; Plasencia Gutierrez, Manuel

    2003-01-01

    The irradiation service is part of the specialized technician scientist services of the Center of Technological Applications and Nuclear Development it belonging to the Radiobiological Department it provides a self shielded laboratory irradiator, PX y 30 type with Cobalt 60 sources, it destined for searches studies, so much basic as applying, in several branches of the science, like the radiobiology, the radiation chemistry, the solid state physics, the medicine, the agriculture and the Pharmaceutical- Medical Industry and besides offering the irradiation service properly with the which have been gotten significant economical outputs. The radiation processing is controlled by means of the dosimetric systems of Freckle, ceric cerous sulfate, Perspex (red, clear and Amber) and dose indicators

  17. Industry sector analysis, Mexico: Electric power production and distribution equipment. Export Trade Information

    International Nuclear Information System (INIS)

    Wood, J.S.; Miller, R.W.

    1988-09-01

    The Industry Sector Analyses (I.S.A.) for electric power production and distribution equipment contains statistical and narrative information on projected market demand, end-users, receptivity of Mexican consumers to U.S. products, the competitive situation - Mexican production, total import market, U.S. market position, foreign competition, and competitive factors, and market access - Mexican tariffs, non-tariff barriers, standards, taxes and distribution channels. The I.S.A. provides the United States industry with meaningful information regarding the Mexican market for electric power production and distribution equipment

  18. A Method of Numerical Control Equipment Appearance Design Based on Product Identity

    Science.gov (United States)

    Zhu, Zhijuan; Zhou, Qi; Li, Bin; Visser, Steve

    Research on numerical control (NC) equipment has been more and more abundant; however, there are few existing studies in the field of appearance design for NC equipments. This paper provided a method to generate new appearance design of NC equipments based on product identity (PI). For the purpose of providing guidelines to generate new concept of NC equipment design, this paper, therefore, took the DMG Company (a Germen NC equipment company) as a case, examined the total products of this company from two aspects: Product Image and Product Family. Task 1 was an evaluate task about the Product Image by using the semantic differential (SD) evaluation method; Task 2 was a study task about Product Family to find out features of the products and classify these features. During the Task 2, several features have been found out and summarized, and these features were classified into 3 different levels according to their frequency and importance. In the end, two appearance design samples have been generated based on the analysis above to prove the application of the research.

  19. A novel approach to collaborative product development in the medical-equipment industry

    OpenAIRE

    Tseng, Kevin C; Chien-Lung, Hsu

    2013-01-01

    In this study, we summarise the requirements for collaborative product development based on our investigation of the differences in the resources and tools that are needed for the various stages of collaborative product development and the needs of system users during these various stages. We proposed a user-oriented approach of collaborative product development for medical equipment and designed a collaborative product development system with the required functionalities to satisfy different...

  20. A Decision Optimization Model for Leased Manufacturing Equipment with Warranty under Forecasting Production/Maintenance Problem

    Directory of Open Access Journals (Sweden)

    Zied Hajej

    2015-01-01

    Full Text Available Due to the expensive production equipment, many manufacturers usually lease production equipment with a warranty period during a finite leasing horizon, rather than purchasing them. The lease contract contains the possibility of obtaining an extended warranty for a given additional cost. In this paper, based on the forecasting production/maintenance optimization problem, we develop a mathematical model to study the lease contract with basic and extended warranty based on win-win relationship between the lessee and the lessor. The influence of the production rates in the equipment degradation consequently on the total cost by each side during the finite leasing horizon is stated in order to determine a theoretical condition under which a compromise-pricing zone exists under different possibilities of maintenance policies.

  1. Production capacity of equipment for medium and large hydroelectric power plant in China

    Energy Technology Data Exchange (ETDEWEB)

    Huang Shenyang [Ministry of Electric Power, Beijing (China). Bureau of Electric Power Machinery

    1995-07-01

    This document presents an overview on the production capacity of equipment for medium and large hydroelectric power plant in China. The document approaches general aspects, production capability and testing facilities related to Francis, Kaplan, tubular and impulse hydroelectric generating sets, and the introduction of main manufacturers as well.

  2. Improvement of Productivity in TIG Welding Plant by Equipment Design in Orbit

    Science.gov (United States)

    Gnanavel, C.; Saravanan, R.; Chandrasekaran, M.; Jayakanth, J. J.

    2017-03-01

    Measurements and improvements are very indispensable task at all levels of management. Here some samples are, at operator level: Measuring operating parameters to ensure OEE (Overall Equipment Effectiveness) and measuring Q components performance to ensure quality, at supervisory level: measuring operator’s performance to ensure labour utility at managerial level: production and productivity measurements and at top level capital and capacity utilization. An often accepted statement is “Improvement is impossible without measurement”. Measurements often referred as observation. The case study was conducted at Government Boiler factory in India. The scientific approach followed for indentifying non value added activities. Personalised new equipment designed and installed to achieve productivity improvement of 85% for a day. The new equipment can serve 360o around its axis hence it simplified loading and unloading procedures as well as reduce their times and ensured effective space and time.

  3. Communication Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 2209

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2009

    2009-01-01

    The graduate of the Communication Technician apprenticeship program is a certified journeyperson who will be able to: (1) supervise, train and coach apprentices; (2) use a thorough knowledge of electrical and electronic theory and its application to communication and associated equipment used in the telecommunication industry; (3) understand…

  4. Pulmonary Foreign Body Granulomatosis in Dental Technician.

    Science.gov (United States)

    Chung, Sung Jun; Koo, Gun Woo; Park, Dong Won; Kwak, Hyun Jung; Yhi, Ji Young; Moon, Ji-Yong; Kim, Sang-Heon; Sohn, Jang Won; Yoon, Ho Joo; Shin, Dong Ho; Park, Sung Soo; Pyo, Ju Yeon; Oh, Young-Ha; Kim, Tae-Hyung

    2015-10-01

    Occupational lung diseases are caused by several toxic substances including heavy metals; however, the exact pathologic mechanisms remain unknown. In the workplace, dental technicians are often exposed to heavy metals such as cobalt, nickel, or beryllium and occasionally develop occupational lung diseases. We described a case of occupational lung disease in a patient who was employed as a dental technician for over a decade. A 31-year-old, non-smoking woman presented with productive cough and shortness of breath of several weeks duration. Chest computed tomography revealed a large number of scattered, bilateral small pulmonary nodules throughout the lung field, and multiple mediastinal lymph nodes enlargement. Percutaneous needle biopsy showed multifocal small granulomas with foreign body type giant cells suggestive of heavy metals inhalation. The patient's condition improved on simple avoidance strategy for several months. This case highlighted the importance of proper workplace safety.

  5. Notice to exporters on products prohibited from export (nuclear material, equipment and large nuclear units)

    International Nuclear Information System (INIS)

    1988-01-01

    In order to ensure that the policy to avoid the proliferation of nuclear weapons is complied with, the French Administration applies stricter controls over the export of certain sensitive products, materials and equipment. To this effect, lists of such products, materials and equipment are published in the form of Notices to exporters and periodically revised. This Notice repeals and replaces the previous Notice published in the Official Gazette of 21 January 1986. Annex I contains the list of materials whose export is subject to nuclear non-proliferation controls. Annex II lists the equipment whose export is subject to the same controls. Annex III includes the list of large nuclear units for which an application for prior approval of export must be submitted to the Administrations concerned. (NEA) [fr

  6. Costs and indices for domestic oil and gas field equipment and production operations, 1992--1995

    International Nuclear Information System (INIS)

    1996-08-01

    This report presents estimated costs and cost indices for domestic oil and natural gas field equipment and production operations for 1992, 1993, 1994, and 1995. The costs of all equipment and services are those in effect during June of each year. The sum (aggregates) of the costs for representative leases by region, depth, and production rate were averaged and indexed. This provides a general measure of the increased or decreased costs from year to year for lease equipment and operations. These general measured do not capture changes in industry-wide costs exactly because of annual variations in the ratio of the total number of oil wells to the total number of gas wells. The detail provided in this report is unavailable elsewhere. The body of this report contains summary tables, and the appendices contain detailed tables

  7. 78 FR 40388 - Inadmissibility of Consumer Products and Industrial Equipment Noncompliant With Applicable Energy...

    Science.gov (United States)

    2013-07-05

    ... products and equipment and exercise reasonable care in the importation thereof. While it is not within CBP... refusal of admission may take place, this document adds language in the final rule to 19 CFR 12.50(b) that... ``refusal of admission''; a newly redesignated [[Page 40390

  8. RISK CONNECTED WITH AIRCRAFT PRODUCTION IN ACCORDANCE WITH MINIMUM EQUIPMENT LIST (MEL

    Directory of Open Access Journals (Sweden)

    R. V. Enikeev

    2014-01-01

    Full Text Available The article covers the problem of understanding of risk assessment necessity connected with aircraft production in accordance with Minimum Equipment List (MEL. The article presents calculation of fail-safe performance probability of Airbus A320 Family fuel system in the event of defect which rectification is postponed in accordance with MEL. The article also presents the results of risk assessment connected with aircraft production in accordance with MEL.

  9. Prospective areas in the production technology of scientific equipment for space research

    Science.gov (United States)

    Breslavets, A. V.

    1974-01-01

    The average labor of individual types of operations in the percentage ratio of the total labor consumption of manufacturing scientific instruments and apparatus for space research is presented. The prospective areas in the production technology of billet, machining, mechanical assembly, installation and assembly, adjustment and regulation and testing and control operations are noted. Basic recommendations are made with respect to further reduction of labor consumption and an increase in the productivity of labor when manufacturing scientific equipment for space research.

  10. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... foam production—HAP emissions from equipment cleaning. Each owner or operator of a new or existing...(a)(1) shall not use a HAP or a HAP-based material as an equipment cleaner. ...

  11. Costs and indices for domestic oil and gas field equipment and production operations 1990 through 1993

    International Nuclear Information System (INIS)

    1994-01-01

    This report presents estimated costs and indice for domestic oil and gas field equipment and production operations for 1990, 1991, 1992, and 1993. The costs of all equipment and serives were those in effect during June of each year. The sums (aggregates) of the costs for representative leases by region, depth, and production rate were averaged and indexed. This provides a general measure of the increased or decreased costs from year to year for lease equipment and operations. These general measures do not capture changes in industry-wide costs exactly because of annual variations in the ratio of oil wells to gas wells. The body of the report contains summary tables, and the appendices contain detailed tables. Price changes for oil and gas, changes in taxes on oil and gas revenues, and environmental factors (costs and lease availability) have significant impact on the number and cost of oil and gas wells drilled. These changes also impact the cost of oil and gas production equipment and operations

  12. Costs and indices for domestic oil and gas field equipment and production operations 1990 through 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-08

    This report presents estimated costs and indice for domestic oil and gas field equipment and production operations for 1990, 1991, 1992, and 1993. The costs of all equipment and serives were those in effect during June of each year. The sums (aggregates) of the costs for representative leases by region, depth, and production rate were averaged and indexed. This provides a general measure of the increased or decreased costs from year to year for lease equipment and operations. These general measures do not capture changes in industry-wide costs exactly because of annual variations in the ratio of oil wells to gas wells. The body of the report contains summary tables, and the appendices contain detailed tables. Price changes for oil and gas, changes in taxes on oil and gas revenues, and environmental factors (costs and lease availability) have significant impact on the number and cost of oil and gas wells drilled. These changes also impact the cost of oil and gas production equipment and operations.

  13. Costs and indices for domestic oil and gas field equipment and production operations 1994 through 1997

    International Nuclear Information System (INIS)

    1998-03-01

    This report presents estimated costs and cost indices for domestic oil and natural gas field equipment and production operations for 1994, 1995, 1996, and 1997. The costs of all equipment and services are those in effect during June of each year. The sums (aggregates) of the costs for representative leases by region, depth, and production rate were averaged and indexed. This provides a general measure of the increased or decreased costs from year to year for lease equipment and operations. These general measures do not capture changes in industry-wide costs exactly because of annual variations in the ratio of the total number of oil wells to the total number of gas wells. The detail provided in this report is unavailable elsewhere. The body of this report contains summary tables, and the appendices contain detailed tables. Price changes for oil and gas, changes in taxes on oil and gas revenues, and environmental factors (compliance costs and lease availability) have a significant impact on the number and cost of oil and gas wells drilled. These changes also impact the cost of oil and gas equipment and production operations

  14. Calibration of the indicators of the product KERMa-AREA in radiodiagnostic equipment

    International Nuclear Information System (INIS)

    Ginjaume, M.; Jarvinen, H.; Turak, O.

    2013-01-01

    Currently the IAEA proposes two procedures for the calibration of the determination of the PKA systems integrated in the x-ray equipment. The traditional method is to measure air kerma at a certain distance from the focus through an ionization chamber reference and then the area of the field of radiation in that position. The alternative method is based on measuring directly the product kerma-area using equipment calibrated in this magnitude. In both cases the calibration procedure takes into account the position of the tube on the stretcher of the patient. The objective of this study was to compare the practical application of both calibration procedures as well as assess the accuracy of indication of the PKA in the consoles of the radiology equipment. (Author)

  15. The effect of equipment efficiency on occurrence of non-conforming products in die casting

    Directory of Open Access Journals (Sweden)

    S. Borkowski

    2010-01-01

    Full Text Available This study focuses on determination of the relationships between equipment efficiency in casting machines and the level of quality. The determination was made based on coefficients of Total Productive Maintenance and r correlation coefficient. The degree at which break-downs and downtime affect the occurrence of non-conforming products was also evaluated. The goal of further investigations is to deter-mine the structure of downtime and finding which downtime types have greatest impact on the quality of die-casting products.

  16. Integrated configurable equipment selection and line balancing for mass production with serial-parallel machining systems

    Science.gov (United States)

    Battaïa, Olga; Dolgui, Alexandre; Guschinsky, Nikolai; Levin, Genrikh

    2014-10-01

    Solving equipment selection and line balancing problems together allows better line configurations to be reached and avoids local optimal solutions. This article considers jointly these two decision problems for mass production lines with serial-parallel workplaces. This study was motivated by the design of production lines based on machines with rotary or mobile tables. Nevertheless, the results are more general and can be applied to assembly and production lines with similar structures. The designers' objectives and the constraints are studied in order to suggest a relevant mathematical model and an efficient optimization approach to solve it. A real case study is used to validate the model and the developed approach.

  17. Practical analog electronics for technicians

    CERN Document Server

    Kimber, W A

    2013-01-01

    'Practical Analog Electronics for Technicians' not only provides an accessible introduction to electronics, but also supplies all the problems and practical activities needed to gain hands-on knowledge and experience. This emphasis on practice is surprisingly unusual in electronics texts, and has already gained Will Kimber popularity through the companion volume, 'Practical Digital Electronics for Technicians'. Written to cover the Advanced GNVQ optional unit in electronics, this book is also ideal for BTEC National, A-level electronics and City & Guilds courses. Together with 'Practical Digit

  18. How do laboratory technicians perceive their role in the tuberculosis diagnostic process? A cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia.

    Science.gov (United States)

    Widjanarko, Bagoes; Widyastari, Dyah Anantalia; Martini, Martini; Ginandjar, Praba

    2016-01-01

    Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB) diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians. This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables. Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%-75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled. Most of the laboratory technicians believed that they have an important role in TB patients' treatment and should display proper self-efficacy in performing laboratory activities. The result may serve as a basic consideration to develop a policy for enhancing motivation of laboratory technicians in order to improve the TB control program.

  19. Solar Technician Program Blows Hot

    Science.gov (United States)

    Ziegler, Peg Moran

    1977-01-01

    A training program for solar heating technicians was initiated at Sonoma State College's School of Environmental Studies for CETA applicants. Among the projects designed and built were a solar alternative energy center, a solar hot water system, and a solar greenhouse. (MF)

  20. Robotics/Automated Systems Technicians.

    Science.gov (United States)

    Doty, Charles R.

    Major resources exist that can be used to develop or upgrade programs in community colleges and technical institutes that educate robotics/automated systems technicians. The first category of resources is Economic, Social, and Education Issues. The Office of Technology Assessment (OTA) report, "Automation and the Workplace," presents analyses of…

  1. Environmental and ventilation benefits for underground mining operations using fuel cell powered production equipment

    International Nuclear Information System (INIS)

    Kocsis, C.; Hardcastle, S.

    2007-01-01

    The benefits of replacing diesel engines with fuel cells in mine production equipment were discussed. The paper was part of a multi-year feasibility study conducted to evaluate the use of hydrogen fuel cell-powered equipment to replace diesel engine powered equipment in underground mining operations. The feasibility study demonstrated that fuel cells are capable of eliminating the unwanted by-products of combustion engines. However, the use of fuel cells also reduced the amount of ventilation that mines needed to supply, thereby further reducing energy consumption. This study examined the benefits of replacing diesel engines with fuel cells, and discussed the mitigating qualifiers that may limit ventilation energy savings. Solutions to retaining and maintaining additional ventilation in the event of hydrogen leaks from fuel cell stacks were also investigated. The analyses were conducted on 6 operating mines. Current operating costs were compared with future operating conditions using fuel cell powered production vehicles. Operating costs of the primary ventilation system were established with a mine ventilation simulator. The analysis considered exhaust shaft velocities, heating system air velocities, and levels of silica exposure. Canadian mine design criteria were reviewed. It was concluded that appropriate safeguards are needed along hydrogen distribution lines to lower the impacts of hydrogen leaks. Large financial commitments may also be required to ensure a spark-free environment. 20 refs., 6 tabs., 3 figs

  2. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  3. Technician checks the mirrors of the Starshine-2 experiment

    Science.gov (United States)

    2001-01-01

    Technician checks the mirrors of the Starshine-2 experiment KSC-01PD-1715 KENNEDY SPACE CENTER, Fla. -- A technician checks the mirrors on the Starshine-2 experiment inside a canister in the payload bay of Space Shuttle Endeavour. The deployable experiment is being carried on mission STS-108. Starshine-2's 800 aluminum mirrors were polished by more than 25,000 students from 26 countries. Top priorities for the STS-108 (UF-1) mission of Endeavour are rotation of the International Space Station Expedition Three and Expedition Four crews, bringing water, equipment and supplies to the station in the Multi-Purpose Logistics Module Raffaello, and completion of robotics tasks and a spacewalk to install thermal blankets over two pieces of equipment at the bases of the Space Station's solar wings. Liftoff of Endeavour on mission STS-108 is scheduled for 7:41 p.m. EST.

  4. Two tools for environmentally conscious designers and product developers of electrical & electronic equipment (EEE)

    DEFF Research Database (Denmark)

    Poll, Christian; Hauschild, Michael Zwicky; Olsen, Stig Irving

    2002-01-01

    The paper presents the two tools 1)"Product families - short cuts to environmental knowledge" and 2)"Eco-conscious design of electrical & electronic equipment (EEE)". Tool 1) comes in form of a handbook. The purpose of this handbook is to ease the work with developing more environmentally sound...... products, thus giving guidelines for development of new products without the companies themselves having to perform an LCA. The handbook describes 5 productfamilies: mobile phones, vacuum cleaners, industrial valves with electronic controls, lighting, ventilation. Tool 2) comes in form of a software tool...... with built in training, guidance, references, calculator and database. The tool provides the basic understanding of how EEE-products in general interact with the environment. The tool gives an overview of the tasks and responsibilities involved in Eco-Desing, and examples of how to choose and quantify...

  5. Radiological Control Technician: Phase 1, Site academic training study guides

    International Nuclear Information System (INIS)

    1992-10-01

    This volume is a study guide for training Radiological Control Technicians. Provided herein are support materials for learning radiological documentation, communication systems, counting errors and statistics, dosimetry, contamination control, airborne sampling program methods, respiratory protection, radiological source control, environmental monitoring, access control and work area setup, radiological work coverage, shipment and receipt for radioactive material, radiological incidents and emergencies, personnel decontamination, first aid, radiation survey instrumentation, contamination monitoring, air sampling, and counting room equipment

  6. Capabilities for managing high-volume production of electric engineering equipment at the Electrochemical Production Plant

    Energy Technology Data Exchange (ETDEWEB)

    Podlednev, V.M.

    1996-04-01

    The Electromechanical Production Plant is essentially a research center with experimental facilities and power full testing base. Major products of the plant today include heat pipes and devices of their basis of different functions and power from high temperature ranges to cryogenics. This report describes work on porous titanium and carbon-graphite current collectors, electrocatalyst synthesis, and electrocatalyst applications.

  7. Targeting overall equipment efficiency for small medium enterprises with irregular production system

    Science.gov (United States)

    Prasetyawan, Y.; Suef, M.; Claudia, L.; Handayani, F. D.

    2018-04-01

    Overall Equipment Effectiveness (OEE) is widely used to measure the maturity of a production system. The company will be considered as World Class Manufacturing if it reaches more than 85% value, with near perfect value for availability, performance and quality factor. This assessment is usually taken on industries with regular production times named shift system. A typical 8 hours shift system is used in OEE measurement and performance monitoring. There are few Small to Medium Enterprise (SME) perform regular production times with shift systems, others using irregular production systems. The irregular production time in the SME production system is used because of demand fluctuations. This paper shows a quantitative analysis as a part of manufacturing system design to achieve a specific value of OEE for SME with irregular production systems, for individual businesses as well as collective business systems (some companies use the same production facilities for several processes). The results of experiments on several companies are presented, as a basis for determining the technical strategy of achieving OEE values.

  8. 9 CFR 381.201 - Means of conveyance and equipment used in handling poultry products offered for entry to be...

    Science.gov (United States)

    2010-01-01

    ... INSPECTION AND CERTIFICATION POULTRY PRODUCTS INSPECTION REGULATIONS Imported Poultry Products § 381.201... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Means of conveyance and equipment used in handling poultry products offered for entry to be maintained in sanitary condition. 381.201...

  9. Clinical Experience and Learning Style of Flight Nurse and Aeromedical Evacuation Technician Students.

    Science.gov (United States)

    De Jong, Marla J; Dukes, Susan F; Dufour, Karey M; Mortimer, Darcy L

    2017-01-01

    The clinical experience and preferred learning style of U.S. Air Force flight nurses and aeromedical evacuation technicians are unknown. Using a cross-sectional survey design, we gathered data regarding the clinical experience, level of comfort providing clinical care, and preferred learning style of 77 active duty (AD), Air Force Reserve (AFR), and Air National Guard (ANG) nurses enrolled in the U.S. Air Force School of Aerospace Medicine Flight Nurse course, and 121 AD, AFR, and ANG medical technicians enrolled in the Aeromedical Evacuation Technician course. Nurses and medical technicians reported 7.6 ± 5.5 and 3.9 ± 4.5 yr of experience, respectively. AD, AFR, and ANG nurses had comparable years of experience: 5.8 ± 3.2, 8.3 ± 6.6, and 7.9 ± 4.2 yr, respectively; however, AD medical technicians had more years of experience (5.6 ± 4.4 yr) than AFR (3.1 ± 4.8 yr) and ANG (1.9 ± 2.8 yr) medical technicians. Both nurses and medical technicians reported infrequently caring for patients with various disease processes and managing equipment or devices that they will routinely encounter when transporting patients as an aeromedical evacuation clinician. Nurses and medical technicians preferred a kinesthetic learning style or a multimodal learning style that included kinesthetic learning. Nearly all (99%) nurses and 97% of medical technicians identified simulation as their preferred teaching method. These findings confirm faculty concerns regarding the clinical experience of flight nurse and aerospace evacuation technician students.De Jong MJ, Dukes SF, Dufour KM, Mortimer DL. Clinical experience and learning style of flight nurse and aeromedical evacuation technician students. Aerosp Med Hum Perform. 2017; 88(1):23-29.

  10. Production equipment development needs for a 700 metric ton/year light water reactor mixed oxide fuel manufacturing plant

    International Nuclear Information System (INIS)

    Blahnik, D.E.

    1977-09-01

    A literature search and survey of fuel suppliers was conducted to determine how much development of production equipment is needed for a 700 metric tons/y LWR mixed-oxide (UO 2 --PuO 2 ) fuel fabrication plant. Results indicate that moderate to major production equipment development is needed in the powder and pellet processing areas. The equipment in the rod and assembly processing areas need only minor development effort. Required equipment development for a 700 MT/y plant is not anticipated to delay startup of the plant. The development, whether major or minor, can be done well within the time frame for licensing and construction of the plant as long as conventional production equipment is used

  11. Validation of the production process of core-equipment HYNIC-Bombesin-Sn

    International Nuclear Information System (INIS)

    Rubio C, N. I.

    2008-01-01

    The validation process is establishing documented evidence that provides a high degree of assurance that a specific process consistently will produce a product that will meet specifications and quality attributes preset and, therefore, ensures the efficiency and effectiveness of a product. The radiopharmaceutical 99m Tc-HYNlC-Bombesin is part of the gastrin-releasing peptide (GRP) analogues of bombesin that are radiolabelled with technetium 99 metastable for molecular images obtention. Is obtained from freeze-dry formulations kits (core- equipment)) and has reported a very high stability in human serum, specific binding to receptors and rapid internalization. Biodistribution data in mice showed rapid blood clearance with predominant renal excretion and specific binding to tissues with positive response to GRP receptors. According to biokinetics studies performed on patients with breast cancer, breast show a marked asymmetry with increased uptake in neoplastic breast in healthy women and the uptake of radiopharmaceuticals is symmetrical in both breasts. No reported adverse reactions. In this paper, the prospective validation core-equipment HYNlC-Bombesin-Sn, which was shown consistently that the product meets the specifications and quality, attributes to preset from the obtained from the diagnostic radiopharmaceutical third generation: 99m Tc-HYNlC-Bombesin. The process was successfully validated and thereby ensuring the efficiency and effectiveness of this agent as a preliminary diagnostic for approval to be marketed. (Author)

  12. Training pharmacy technicians to administer immunizations.

    Science.gov (United States)

    McKeirnan, Kimberly C; Frazier, Kyle R; Nguyen, Maryann; MacLean, Linda Garrelts

    To evaluate the effectiveness of an immunization training program for pharmacy technicians on technicians' self-reported confidence, knowledge, and number of vaccines administered. A one-group pre- and posttest study was conducted with certified pharmacy technicians from Albertsons and Safeway community pharmacies in Idaho. Thirty pharmacy technicians were recruited to participate in an immunization administration training program comprising a 2-hour home study and a 2-hour live training. Pharmacy technician scores on a 10-question knowledge assessment, responses on a pre- and posttraining survey, and number of immunizations administered in the 6-month period following the training were collected. Twenty-five pharmacy technicians completed the home study and live portions of the immunization training program. All 29 pharmacy technicians who took the home study assessment passed with greater than 70% competency on the first attempt. Technicians self-reported increased confidence with immunization skills between the pretraining survey and the posttraining survey. From December 2016 to May 2017, the technicians administered 953 immunizations with 0 adverse events reported. For the first time, pharmacy technicians have legally administered immunizations in the United States. Trained pharmacy technicians demonstrated knowledge of vaccination procedures and self-reported improved confidence in immunization skills and administered immunizations after participating in a 4-hour training program. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  13. 40 CFR 63.1296 - Standards for slabstock flexible polyurethane foam production-HAP ABA equipment leaks.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production-HAP ABA equipment leaks. 63.1296 Section 63.1296 Protection of Environment... production—HAP ABA equipment leaks. Each owner or operator of a new or existing slabstock affected source complying with the emission point specific limitation option provided in § 63.1293(a) shall control HAP ABA...

  14. Transport Refrigeration Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4112

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Transport Refrigeration Technician apprenticeship program is a certified journeyperson who will be able: (1) to diagnose repair, maintain and operate transport refrigeration equipment used to heat or cool the load as well as of diesel engines, APUs and other prime movers; (2) to use tools and equipment in order to carry out…

  15. New electron-ion-plasma equipment for modification of materials and products surface

    International Nuclear Information System (INIS)

    Koval', N.N.

    2013-01-01

    Electron-ion-plasma treatment of materials and products, including surface clearing and activation, formation surface layers with changed chemical and phase structure, increased hardness and corrosion resistance; deposition of various functional coatings, has received a wide distribution in a science and industry. Widespread methods of ion-plasma modification of material and product surfaces are ion etching and activation, ion-plasma nitriding, arc or magnetron deposition of functional coatings, including nanostructured. The combination of above methods of surface modification allows essentially to improve exploitation properties of treated products and to optimize the characteristics of modified surfaces for concrete final requirements. For the purpose of a combination of various methods of ion-plasma treatment in a single work cycle at Institute of High Current Electronics of SB RAS (IHCE SB RAS) specialized technological equipment 'DUET', 'TRIO' and 'QUADRO' and 'KVINTA' have been developed. This equipment allow generating uniform low-temperature gas plasma at pressures of (0.1-1) Pa with concentration of (10 9 -10 11 ) cm -3 in volume of (0.1-1) m 3 . In the installations consistent realization of several various operations of materials and products treatment in a single work cycle is possible. The operations are preliminary heating and degassing, ion clearing, etching and activation of materials and products surface by plasma of arc discharges; chemicothermal treatment (nitriding) for formation of diffusion layer on a surface of treated sample using plasma of nonself-sustained low-pressure arc discharge; deposition of single- or multilayered superhard (≥40 GPa) nanocrystalline coatings on the basis of pure metals or their compounds (nitrides, carbides, carbonitrides) by the arc plasma-assisted method. For realization of the modes all installations are equipped by original sources of gas and metal plasma. Besides, in

  16. Method of processing dismantled products of radiation-contaminated equipments and transportation container therefor

    International Nuclear Information System (INIS)

    Komura, Shiro; Heki, Hideaki.

    1991-01-01

    In a method of decontaminating dismantled products of radiation-contaminated equipments removed at nuclear power facilities and classifying the dismantled products depending on their remaining radioactivity levels measured at a processing facility, the dismantled products are contained in a transportation container, to which decontamination liquids are injected and they are transferred to the processing facility. The decontaminated liquid wastes are drained from the transportation container, the dismantled products are washed while being contained in the transportation container as they are. Then, they are transferred to a step for measuring their remaining radioactivity level. This can shorten the time from the containment of the dismantled products to the transportation container to the completion of the decontamination, to improve the efficiency for the decontamination processing. Further, by separately containing the dismantled products on every kind of materials to respective containers, the processing time can be appropriately controlled respectively even if the dissolving efficiency to the decontamination liquids is different depending on the materials. (T.M.)

  17. Mobile equipment maintenance at Elk Valley Coal Corporation Fording River

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Major loading and support equipment, haul trucks, and the number of staff and hourly tradesmen working in the maintenance manpower division at Elk Valley Coal are listed. Maintenance strategies are safety, high maintenance of equipment availabilities and reliability, cost reduction, and maximized productivity of assets. Maintenance assets comprise a large shop, shovel and drill crew, machine shop, light vehicle facility, line crew, radio technicians, and cranes. Most maintenance work is completed in- house. Fording River uses a Computerized Maintenance Management System (CMMS) that was developed in-house to match business needs. Several examples of the application of Reliability Centered Maintenance (RCM) are described. 12 figs., 2 tabs.

  18. REVEALING OF DEFECTS OF BEARINGS WITH THE HELP OF MODERN METHODS OF CONTROL OF TECHNOLOGICAL EQUIPMENT OF HARDWARE PRODUCTION

    Directory of Open Access Journals (Sweden)

    S. M. Piskun

    2010-01-01

    Full Text Available It is shown that using of modern methods and means of technical diagnostics will allow to provide reliable accident-free exploitation of equipment, to decrease considerably labour-intensiveness, period of repair and accordingly production expenses.

  19. How do laboratory technicians perceive their role in tuberculosis diagnostic process: a cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia

    Directory of Open Access Journals (Sweden)

    Widjanarko B

    2016-09-01

    Full Text Available Bagoes Widjanarko,1 Dyah Anantalia Widyastari,2 Martini Martini,3 Praba Ginandjar3 1Department of Health Education and Behavior Sciences, Faculty of Public Health, Diponegoro University, Semarang, Indonesia; 2Institute for Population and Social Research, Mahidol University, Salaya, Thailand; 3Department of Epidemiology, Faculty of Public Health, Diponegoro University, Semarang, Indonesia Purpose: Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians.Methods: This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables.Results: Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%–75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled.Conclusion: Most of the laboratory technicians believed that they have an important role in TB patients’ treatment and should display proper self-efficacy in performing laboratory activities. The

  20. PRODUCTIVITY, TECHNICAL EQUIPMENT AND SALES. EMPIRICAL EVIDENCE FROM THE ROMANIAN COMPANIES

    Directory of Open Access Journals (Sweden)

    DEMYEN SUZANA

    2015-12-01

    Full Text Available The relationship between turnover and organizational performance represented the field of interest for various authors in literature, some of the studies identifying even a strong association between the organizational performance and the management of human resources itself. Turnover thus represents an indicator of results which has a fundamental role in characterizing the efficiency of the activity carried out by a company. The final results are conditioned by the volume of resources, which are however, limited, an efficient strategy of management being necessary for the correct accomplishment of the previous established objectives and capitalization of its real potential. Findings regarding the size of a business or a company and its variation in time are necessary in attracting and securing the resources which are indispensable for achieving the objectives and goals proposed. To fully understand a company's activity, any analysis of an indicator must include a description of its dynamics. Thus, the analysis of the turnover in time can be achieved using conventional statistical models. In concrete terms, it is part of the economic and financial results indicators, helping to diagnose and to evaluate the company, estimating efficient management practices. The present paper aims at illustrating the relevance of a factorial analysis model for a sample of enterprises selected, the results highlighting the connection between the sales and labor productivity, but also between sales and the degree of technical equipment. The study revealed the following aspects: a positive and direct connection between labor productivity and sales, so we can state that higher levels of productivity produce higher sales, but also a negative connection between the degree of technical equipment and the level of sales, relation which is very important since we want to know how well a business is employing its assets to generate sales.

  1. Precise control of lycopene production to enable a fast-responding, minimal-equipment biosensor.

    Science.gov (United States)

    McNerney, Monica P; Styczynski, Mark P

    2017-09-01

    Pigmented metabolites have great potential for use in biosensors that target low-resource areas, since sensor output can be interpreted without any equipment. However, full repression of pigment production when undesired is challenging, as even small amounts of enzyme can catalyze the production of large, visible amounts of pigment. The red pigment lycopene could be particularly useful because of its position in the multi-pigment carotenoid pathway, but commonly used inducible promoter systems cannot repress lycopene production. In this paper, we designed a system that could fully repress lycopene production in the absence of an inducer and produce visible lycopene within two hours of induction. We engineered Lac, Ara, and T7 systems to be up to 10 times more repressible, but these improved systems could still not fully repress lycopene. Translational modifications proved much more effective in controlling lycopene. By decreasing the strength of the ribosomal binding sites on the crtEBI genes, we enabled full repression of lycopene and production of visible lycopene in 3-4h of induction. Finally, we added the mevalonate pathway enzymes to increase the rate of lycopene production upon induction and demonstrated that supplementation of metabolic precursors could decrease the time to coloration to about 1.5h. In total, this represents over an order of magnitude reduction in response time compared to the previously reported strategy. The approaches used here demonstrate the disconnect between fluorescent and metabolite reporters, help enable the use of lycopene as a reporter, and are likely generalizable to other systems that require precise control of metabolite production. Copyright © 2017 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  2. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica

    2010-01-01

    This paper presents a survey of parameters for the proper and safe flooring, doors, windows, fume hoods and others, in a radiochemical laboratory. The layout of each item follows guidelines and national standards of the National Commission of Nuclear Energy (CNEN) and the International Atomic Energy Agency (IAEA), aiming to ensure the radiological protection of workers and environment. The adequate items arrangement in the radiochemical laboratory ensures quality and safety in the production of 57 Co 137 Cs and 133 Ba radioactive sealed sources, with activities 185, 9.3 and 5.4 MBq, respectively. These sources are used to verify meter activity equipment and should be available throughout the Nuclear Medicine Center, following the recommendations of CNEN-NN-3.05 standard R equirements for Radiation Protection and Safety Services for Nuclear Medicine , to verify the activity of radiopharmaceuticals that are administered in patients, for diagnosis and therapy. Verification of measuring activity equipment will be used to perform accuracy, reproducibility and linearity tests, which should show results within the limits specified in the standard CNEN-NN-3.05. (author)

  3. Technicians for the Brazilian nuclear power programme

    International Nuclear Information System (INIS)

    Martins Pinto, C.S.; Spitalnik, J.; Meakins, E.J.; Hurley, I.

    1980-01-01

    The technician has a responsible role to fulfil in nuclear industry, acting as a bridge between the engineer and the skilled worker. Technicians must have sufficient theoretical knowledge to communicate with engineers, and a thorough understanding of technological practice; the nuclear industry demands both theory and practice of a high standard. In Brazil the essential role of the technician in industry is in general recognized. However, the lack of a nationally recognized Nuclear Technician and Nuclear Technologist qualification, as well as a desire of the best technicians to quality as engineers and, in some areas, inadequate salaries has resulted in a shortage of well-trained technicians. A first step to ensure availability of these technicians is to improve their career prospects and status through definition of appropriate career standards and salaries. Practical training by the industry can only be given in factories, plants and construction sites where nuclear work is done. It is proposed to extend apprentice training centres at three sites, to give the most promising students after two years of apprentice training two further years of instruction and practice to qualify as Nuclear Technicians. The training centres are chosen to cover the three sectors of nuclear industry where special training of technicians is important: manufacture and construction; operation and maintenance; and testing and analysis for process control and safety. (author)

  4. Buying, supporting, maintaining software and equipment an IT manager's guide to controlling the product lifecycle

    CERN Document Server

    Gordon-Byrne, Gay

    2014-01-01

    INITIAL PRODUCT ACQUISITIONEquipment and Application AcquisitionIntroductionApplication Selection Dictates Hardware Selection     Background     Application License Acquisition     Going Naked     Operating System AcquisitionAcquisition Model: Direct from the Original Equipment Manufacturer     Platforms as Monopolies     Multiyear Commitments     Operating System and Machine Code License Lock-Ins     Strategic Partnerships     The Win Room     Credible CompetitionAcquisition Model: Channel Partners and Authorized Resellers     Competition between Partner or Channel Sources     Controlling Dis

  5. Study and development of equipment supervision technique system and its management software for nuclear electricity production

    International Nuclear Information System (INIS)

    Zhang Liying; Zou Pingguo; Zhu Chenghu; Lu Haoliang; Wu Jie

    2008-01-01

    The equipment supervision technique system, which standardized the behavior of supervision organizations in planning and implementing of equipment supervision, is built up based on equipment supervision technique documents, such as Quality Supervision Classifications, Special Supervision Plans and Supervision Guides. Furthermore, based on the research, the equipment supervision management information system is developed by Object Oriented Programming, which consists of supervision information, supervision technique, supervision implementation, quality statistics and analysis module. (authors)

  6. 77 FR 76972 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2012-12-31

    ... motors and pumps and certain other industrial equipment to conserve the energy resources of the nation... the efficiency of electric motors, pumps and certain other industrial equipment to conserve the energy... electric motors as covered equipment. A compressor may have some or all of the following components: piston...

  7. 78 FR 68814 - Subzone 114F, Authorization of Production Activity, Easton-Bell Sports, Inc., (Sports Equipment...

    Science.gov (United States)

    2013-11-15

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-74-2013] Subzone 114F, Authorization of Production Activity, Easton-Bell Sports, Inc., (Sports Equipment), Rantoul, Illinois On June 27, 2013, Easton-Bell Sports, Inc. submitted a notification of proposed production activity to the Foreign-Trade Zones...

  8. Overall Equipment Efficiency (OEE Enhancement in Manufacture of Electronic Components & Boards Industry through Total Productive Maintenance Practices

    Directory of Open Access Journals (Sweden)

    Fam Soo-Fen

    2018-01-01

    Full Text Available In an environment of intense global competition, both creative and proven strategies need to be considered in order to bring about the effectiveness and efficiency in manufacturing operation. Total Productive Maintenance (TPM is one of the effective maintenance strategy in enhancing the equipment effectiveness and to achieve a significant competitive advantage. This research paper addresses the impact of three TPM pillars namely planned maintenance (PM, autonomous maintenance (AM and focused maintenance (FM on overall equipment effectiveness (OEE of die attach equipment in the production line of semiconductor industry. The effect of TPM on the OEE is also investigated depending on the equipment types, in where die attach process consist of two models-CANON and ESEC. The primary data was collected from an organization's database and was analysed by SPSS V23. The preliminary results of the analysis showed that the performance of OEE in ESEC is better than the CANON after the implementation of TPM. The analysis also showed that out of the three TPM practices deployed, planned maintenance of equipment by production and maintenance team played the biggest role in increasing the equipment effectiveness. In conclusion, this study provides insights the importance of implementing TPM in order to succeed in a highly demanding market arena.

  9. Spacecraft and propulsion technician error

    Science.gov (United States)

    Schultz, Daniel Clyde

    Commercial aviation and commercial space similarly launch, fly, and land passenger vehicles. Unlike aviation, the U.S. government has not established maintenance policies for commercial space. This study conducted a mixed methods review of 610 U.S. space launches from 1984 through 2011, which included 31 failures. An analysis of the failure causal factors showed that human error accounted for 76% of those failures, which included workmanship error accounting for 29% of the failures. With the imminent future of commercial space travel, the increased potential for the loss of human life demands that changes be made to the standardized procedures, training, and certification to reduce human error and failure rates. Several recommendations were made by this study to the FAA's Office of Commercial Space Transportation, space launch vehicle operators, and maintenance technician schools in an effort to increase the safety of the space transportation passengers.

  10. Analytical chemistry equipment for radioactive products; Installation de chimie analytique pour produits radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Douis, M; Guillon, A; Laurent, H; Sauvagnac, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    The report deals with a shielded enclosure, hermetic, for analytical examination and handling of radioactive products. Remote handling for the following is provided: pipette absorption - weighing - centrifuging - desiccation - volumetric - pH measurement - potentiometric - colorimetric - polarographic. The above list is not restrictive: the enclosure is designed for the rapid installation of other equipment. Powerfully ventilated and screened to 400 m-curies long life fission product levels by 5 cm of lead, the enclosure is fully safe to the stated level. (author) [French] La presente communication decrit une enceinte etanche et blindee permettant un travail et un controle analytique sur des produits radioactifs. Les techniques suivantes sont adaptees pour une manipulation a distance: pipettage, pesees, centrifugation, dessiccation, volumetrie, mesure de pH, potentiometrie, colorimetrie, polarographie. Cette liste n'est pas limitative. La conception de l'installation permet la mise en place rapide d'autres appareils. Protegee par 5 cm de plomb et fortement ventilee, elle donne toute securite de manipulation jusqu'a un niveau d'activite 400 mcuries en produits de fission a vie longue. (auteur)

  11. Defining the Simulation Technician Role: Results of a Survey-Based Study.

    Science.gov (United States)

    Bailey, Rachel; Taylor, Regina G; FitzGerald, Michael R; Kerrey, Benjamin T; LeMaster, Thomas; Geis, Gary L

    2015-10-01

    In health care simulation, simulation technicians perform multiple tasks to support various educational offerings. Technician responsibilities and the tasks that accompany them seem to vary between centers. The objectives were to identify the range and frequency of tasks that technicians perform and to determine if there is a correspondence between what technicians do and what they feel their responsibilities should be. We hypothesized that there is a core set of responsibilities and tasks for the technician position regardless of background, experience, and type of simulation center. We conducted a prospective, survey-based study of individuals currently functioning in a simulation technician role in a simulation center. This survey was designed internally and piloted within 3 academic simulation centers. Potential respondents were identified through a national mailing list, and the survey was distributed electronically during a 3-week period. A survey request was sent to 280 potential participants, 136 (49%) responded, and 73 met inclusion criteria. Five core tasks were identified as follows: equipment setup and breakdown, programming scenarios into software, operation of software during simulation, audiovisual support for courses, and on-site simulator maintenance. Independent of background before they were hired, technicians felt unprepared for their role once taking the position. Formal training was identified as a need; however, the majority of technicians felt experience over time was the main contributor toward developing knowledge and skills within their role. This study represents a first step in defining the technician role within simulation-based education and supports the need for the development of a formal job description to allow recruitment, development, and certification.

  12. Use of individual protection equipment and collective in case of accident during the transport of radioactive product - class 7

    International Nuclear Information System (INIS)

    Pastura, Valeria da F. e S.; Carvalho, Natanael Bruno de

    2013-01-01

    The personal protective equipment (PPE) are devices used by professionals against potential radiological hazards that may threaten the health or safety in the event of an accident or incident during the transport of radioactive material. The collective protection equipment (CPE) devices are used in place of the accident in order to protect people and the environment from risks such as safety signs, among others. This work will be part of the new edition of the NBR 9735 - Set of equipment for emergencies in land transport of dangerous goods - edited by the Brazilian Association of Technical Standards ABNT - National Standardization Forum which CNEN participates in the Study Committee - CB16 namely, dangerous, accounting for Class 7 radioactive materials. The Standard 9735 establishes the minimum set of equipment for emergencies in Inland transport of dangerous goods, consisting of protective equipment to be used by the driver and staff involved (if any) in the transport operations of transport units, equipment for signaling, isolation of the area of occurrence (fault, accident and/or emergency). Thus, we will present a set of individual and collective equipment that must accompany the carriage of Class 7 products to meet the radiological accident situations and also establish a training base for the driver as the use of them. (author)

  13. Regulation on the training-schools and institutions for radiation-technicians and x-ray technicians

    International Nuclear Information System (INIS)

    1977-01-01

    The regulation, in accordance with the Law on X-ray technicians (Law No. 227, 1951), controls and makes rules of the establishment and activities of schools and institutions for those technicians as above mentioned, with intent to secure prescribed qualifications and capabilities of said technicians. Such schools and institutions shall get the designation by relevant ministers of the government who have the power to supervise them, namely the Education Minister and the Minister for Health and Welfare (Article 2). Articles 4 and 4(2) prescribe the standards for the relevant ministers to make the designation of those schools and institutions, in relation to the school years, curriculums, teachers, equipments, etc. According to the standards, those schools and institutions may be of 3-year, 2-year on one-year course according to the required attainment level of students who enters them. The minimum requirement of the attainment is the secondary-school certificates for the 3-year course. The relevant ministers may require such reports from, and give such instructions to those schools and institutions as they consider necessary, and may revoke their designation when such a school on institution has become incompliant with above mentioned standards (Articles 6 and 7). (Matsushima, A.)

  14. GPA/GPSA/OSU-Okmulgee natural gas compression technician training program

    Energy Technology Data Exchange (ETDEWEB)

    Doede, S.

    1999-07-01

    Approximately one year ago, OSU-Okmulgee and the Gas Processors Association began discussions about the possibility of developing a natural Gas Technician Training Program for GPA members. Following a presentation to the Membership and Services Committee, Chairman John Ehlers solicited and obtained the approval of the GPA Executive Committee to sponsor the program. Participation in the program was also made available to GPSA members. The purpose of the program is to upgrade the technical competency and professional level of incoming natural gas compression technicians. It educates students to analytically diagnose, service and maintain gas compression equipment and systems using industry recommended procedures, special tools and service information. It also provides course content, which will enable successful graduates to advance in position after additional experience, and to understand new systems, technologies and components as they are introduced. The two-year Associate-In-Applied Science Degree program includes six successive college semesters. Nearly one-half of the time is designated for technical/academic education at Oklahoma State University-Okmulgee with the balance of time allocated for on-the-job internship experiences at sponsoring GPA/GPSA members. Each block of technical education and general education course work is followed by an immediate work experience time period designated to reinforce the technical and general education. These time periods are approximately seven and one-half weeks in length each. It is essential for the success of the students and the program that the students' education at OSU-Okmulgee and work experiences at GPA/GPSA member facilities be closely aligned for maximum student learning and retention. In addition to technical classes on gas compression equipment and components, the courses offered in math, speech, technical writing, psychology and ethics for example, prepare students to be able to communicate well, get

  15. New technology and energy-saving equipment for production of composite materials

    Science.gov (United States)

    Romanovich, A. A.; Glagolev, S. N.; Babaevsky, A. N.

    2018-03-01

    The article considers industrial technology and energy-saving equipment for cement and composite binder production with a reduction in energy intensity of the process up to 50% due to the synergetic effect during mechanic activation of the raw mix with the replacement of part of the clinker component with the mineral hydro-active additive. The technological process is based on the sequential introduction of components in dispersed phases into the feed mixture in the grinding path and at the stage of product separation with certain dispersed characteristics. The increase in the energy efficiency of the line is achieved by the joint operation of the press roller aggregate, which is the development of BSTU named after V.G. Shoukhov, and rotor-vortex mills of a very fine grinding of a new design. The experienced design of the aggregate with the device for deagglomeration of the pressed tape allows combining the processes of grinding and disaggregation of the pressed material, thereby reducing the operating costs and increasing the efficiency of using the grinding unit. Comparative tests of cement samples obtained in energy-saving aggregates (PRA + RVM) are given which allowed establishing that their beam strength for compression and bending is higher by 15-20% than the traditional method obtained in a ball mill. An analytical expression is also given that allows one to determine the power consumed for the deagglomeration of crushed and pressed material between the main rolls, taking into account the geometric dimensions of the rolls and the physico-mechanical characteristics of the material.

  16. 78 FR 63410 - Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment...

    Science.gov (United States)

    2013-10-24

    ... test procedures for direct heating equipment and pool heaters established under the Energy Policy and... U.S.C. 6293(e)(2)) The current energy conservation standards for direct heating equipment and pool... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2013-BT-TP-0004] RIN 1904-AC94 Energy...

  17. APPRAISAL OF APPLICATION OF WEAR-RESISTANT CHROMIC CAST IRONS FOR PRODUCTION OF MOULDED PIECES OF EQUIPMENT ON PRODUCTION OF BRICK OF CLAY

    Directory of Open Access Journals (Sweden)

    K. E. aranovkij

    2007-01-01

    Full Text Available The appraisal of application of wear-resistant chromic cast irons of different chemical compositions for production of moulded pieces of equipment on production of bricks of clay is carried out. It is determined that working resource of the details of test cast-irons is correlated with their hardness and not lower than of hardened steel.

  18. Use of AI technician scores for body condition, uterine tone and uterine discharge in a model with disease and milk production parameters to predict pregnancy risk at first AI in holstein dairy cows

    NARCIS (Netherlands)

    Loeffler, S.H.; Vries, de M.J.; Schukken, Y.H.; Zeeuw, de A.C.; Dijkhuizen, A.A.; Graaf, de F.M.; Brand, A.

    1999-01-01

    Technicians recorded body condition score (BCS) and several parameters related to estrus and/or metritis for 1694 first insemination cows on 23 farms. Additional variables for modeling the adjusted odds ratios (OR) for pregnancy were data on disease prior to or within 21 days of AI and test day milk

  19. Aplastic anemia in Japanese radiological technicians

    International Nuclear Information System (INIS)

    Kitabatake, T.; Watanabe, T.; Saito, A.; Nakamura, M.; Shiohama Hospital, Mie

    1976-01-01

    Among the Japanese radiological technicians, four deaths from aplastic anemia have been reported after 1930. On the other hand, during the period from 1930 to 1960, the population of radiological technicians is estimated to be 74,400 man-years, in which 0.5 aplastic anemias are expected. However, actually three died from aplastic anemia. This difference is statistically significant at the 1% level. While, in the period from 1961 to 1973, the observed value is 1 against 0.7 expected. It is concluded that aplastic anemia had been induced frequently among the Japanese radiological technicians in the era when there was much exposure to occupational radiation. (orig.) [de

  20. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 5. CPR, Oxygen Therapy. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the fifth in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains two sections covering the following course content; cardiopulmonary resuscitation (CPR) (including artificial ventilation, foreign body obstructions, adjunctive equipment and special techniques, artificial…

  1. Natural Gas Compression Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5311.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Natural Gas Compression Technician apprenticeship program is a certified journeyperson who will be able to install, commission, maintain and repair equipment used to gather store and transmit natural gas. Advanced Education and Technology has prepared this course outline in partnership with the Natural Gas Compression…

  2. O técnico de escolaridade média no setor produtivo: seu novo lugar e suas competências The secondary school technician in the productive sector: his new place and competences

    Directory of Open Access Journals (Sweden)

    João Bosco Laudares

    2003-12-01

    Full Text Available Os convênios recentes estabelecidos entre os Centros de Formação Profissional e as grandes indústrias empregadoras de profissionais técnicos, de nível médio, parecem indicar uma realocação desses profissionais na estrutura de produção. A posição intermediária, entre os operários e os engenheiros ou entre o "chão de fabrica" e o "escritório de projeto", típica da gestão taylorista, tende ao desaparecimento na gestão horizontalizada dos novos modelos organizacionais. A proximidade desses profissionais com os engenheiros passa a demandar deles um nível mais elevado de qualificação, como atesta o aumento da demanda dos setores produtivos industriais de tecnólogos, profissionais de nível superior. Recorre-se à sociologia do trabalho e às noções construídas por ela, de qualificação, de competência e de saber, como forma de se identificar as tendências de mobilidade profissional dos técnicos e dos tecnólogos no interior de grandes empresas industriais.The recent agreements between the Professional Training Centers (at high-school levels and large industries suggest a new position is given to these professionals in the production structure. Their intermediate position between workers and engineers or between "the factory floor" and the "planning department", typical of taylorism, tends to disappear from the horizontal management of the new organizational models. This leads them to need higher levels of qualification, closer to those of engineers, which is proved by the increasing demand of technologists, professionals of superior level, in the productive sector. Drawing on Sociology of Work and its notions of qualification, competence and knowledge, we seek to identify the tendencies of professional mobility of both technicians and technologists in large industries.

  3. Project-oriented management of industrial production of fire and rescue equipment by means of geometric modelling

    OpenAIRE

    Rak, Iu; Bondarenko, V.

    2013-01-01

    Objective: The objective of the research is to develop a method based on the geometric modelling for the purpose of improving the effectiveness of fire protection project management in industrial production of fire protection technology systems. Methods: The theoretical inheritance mode of effective management in project-organizational structure of fire protection and specialized technical equipment production using geometric modelling. Results: Mathematical and geometric models of project ma...

  4. Protective equipment against explosions for offshore oil and gas production; Explosionsgeschuetzte Ausruestung fuer den maritimen Oel- und Gassektor

    Energy Technology Data Exchange (ETDEWEB)

    Popp, Tobias [R. STAHL AG, Waldenburg (Germany)

    2011-05-15

    Offshore oil and gas production requires a multitude of explosion-proof components, systems and solutions both offshore and onshore. They serve different functions, from extraction and separation of fossil fuels to the production and storage of transportable products, sometimes on floating offshore platforms. There are also offshore cranes and pipelines to the onshore terminals. All this requires explostion-proof control cabinets, power distribution units and other equipment. The many different requirements are illustrated by the example of the world's biggest offshore production platform FPSO in the China Sea.

  5. Career Directions--Photonics Technician

    Science.gov (United States)

    Moore, Pam

    2012-01-01

    Many of the advances in telecommunications and medicine are due to laser and fiber-optic technology. This technology has led to devices that provide faster and richer communication, advanced surgeries, and faster healing times, as well as amazing robotics for manufacturing. But, as with all equipment, someone has to install and maintain it. That…

  6. Technician Career Opportunities in Engineering Technology.

    Science.gov (United States)

    Engineers' Council for Professional Development, New York, NY.

    Career opportunities for engineering technicians are available in the technologies relating to air conditioning, heating, and refrigeration, aviation and aerospace, building construction, chemical engineering, civil engineering, electrical engineering, electronics, industrial engineering, instrumentation, internal combustion engines, mechanical…

  7. The Library Technician Programme in Lebanon

    Science.gov (United States)

    Rafidi, Samia

    1973-01-01

    A description of the library technician program established by the Beirut College for Women in February 1970: its curriculum, professional staff, students, and reactions produced by the program is presented. (Author/SJ)

  8. Section 608 Technician Certification Test Topics

    Science.gov (United States)

    Identifies some of the topics covered on Section 608 Technician Certification tests such as ozone depletion, the Clean Air Act and Montreal Protocol, Substitute Refrigerants and oils, Refrigeration and Recovery Techniques.

  9. Particle emissions from ventilation equipment: health hazards, measurement and product development; Ilmanvaihtolaitteiden hiukkaspaeaestoet: terveyshaitat, mittaaminen ja tuotekehitys

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, A.; Tuovila, H.; Riala, R.; Harju, R.; Tuomi, T.; Voutilainen, R. [Tyoeterv.l, Helsinki (Finland); Laamanen, J.; Ismo Heimonen, I.; Kovanen, K. [VTT, Espoo (Finland)

    2006-10-15

    The project aimed to develop the design, structure and materials of ventilation equipment for the improvement of indoor air quality in office- type buildings. Particle emissions from commercial sound silencers were measured by laboratory tests. In ten buildings, the dust and fibre levels were surveyed in relation to the product design and operation. Direct-reading particle counters and filter sampling methods combined with optical and electron microscopy analyses were the main methods in these surveys. Nasal lavage was used for the estimation of inhalation exposure to coarse man-made mineral fibres. Technical criteria were drafted for the design and testing of fibre emissions from various ventilation equipment. (orig.)

  10. Particle emissions from ventilation equipment: health hazards, measurement and product development; Ilmanvaihtolaitteiden hiukkaspaeaestoet: terveyshaitat, mittaaminen ja tuotekehitys - ILMI

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, A.; Paananen, H.; Riala, R.; Tuomi, T.; Voutilainen, R. [Finnish Institute of Occupational Health, Helsinki (Finland); Heimonen, I.; Kovanen, K. [VTT Building and Transport, Espoo (Finland)

    2004-07-01

    The project will develop the design, structure and materials of ventilation equipment for the improvement of indoor air quality in office-type buildings. Particle emissions from commercial products are measured by laboratory tests. In ten buildings, the dust and fibre levels will be surveyed in relation to the design and operation of the ventilation equipment. Direct-reading particle counters and filter sampling method combined with optical and electron microscopy analyses are the main methods in these surveys. Nasal lavage is used for the estimation of inhalation exposure to coarse man-made mineral fibres. Technical criteria will be drafted for the design and testing of fibre emissions from various ventilation equipment. (orig.)

  11. A maturidade e o desempenho das equipes no ambiente produtivo Maturity and performance of teams in the production environment

    Directory of Open Access Journals (Sweden)

    Robson Luiz Montanari

    2011-01-01

    Full Text Available O presente estudo teve como objetivo identificar a influência da maturidade das equipes no desempenho das suas atividades. Para tanto, sete equipes de uma prestadora de serviços foram analisadas. Os procedimentos metodológicos foram permeados por entrevistas, observações não participantes, aplicação de dois questionários e três instrumentos. Os resultados permitiram identificar influências da maturidade no desempenho das equipes em ambiente produtivo, bem como verificar que ela está intimamente relacionada ao comportamento revelado no desempenho dentro do grupo. Nas equipes com maior maturidade, comportamentos indesejáveis ao desempenho coletivo não apareceram na mesma proporção aos das equipes com menor grau de maturidade. Infere-se que, à medida que a maturidade dos grupos é aumentada, pela presença de integrantes mais comprometidos e com confiança mútua, os membros das equipes mudam o comportamento alterando a forma de funcionamento do grupo e transformando-se em uma equipe. Se as equipes em estudo, dentro de uma sequência evolutiva de funcionamento, aumentarem sua maturidade, tendem a influenciar positivamente o seu desempenho no ambiente produtivo em que estão inseridas.This study aimed to identify the influence of maturity of the teams in carrying out its activities. Seven teams of a service provider industry were analyzed. The data were collected through interviews, non-participant observations, application of two questionnaires and three instruments. The results showed the influence of maturity on the performance of teams in the production environment and that it is closely related to the individual behavior within the group. In the teams with more maturity, the presence of undesirable collective behaviors did not occur in the same proportion of that of teams with lesser degrees of maturity. It can be inferred that as the maturity of the groups is increased by the presence of more committed members with mutual

  12. Traveling wire electrode increases productivity of Electrical Discharge Machining /EDM/ equipment

    Science.gov (United States)

    Kotora, J., Jr.; Smith, S. V.

    1967-01-01

    Traveling wire electrode on electrical discharge machining /EDM/ equipment reduces the time requirements for precision cutting. This device enables cutting with a minimum of lost material and without inducing stress beyond that inherent in the material. The use of wire increases accuracy and enables tighter tolerances to be maintained.

  13. A reliability-based maintenance technicians' workloads optimisation model with stochastic consideration

    Science.gov (United States)

    Ighravwe, D. E.; Oke, S. A.; Adebiyi, K. A.

    2016-06-01

    The growing interest in technicians' workloads research is probably associated with the recent surge in competition. This was prompted by unprecedented technological development that triggers changes in customer tastes and preferences for industrial goods. In a quest for business improvement, this worldwide intense competition in industries has stimulated theories and practical frameworks that seek to optimise performance in workplaces. In line with this drive, the present paper proposes an optimisation model which considers technicians' reliability that complements factory information obtained. The information used emerged from technicians' productivity and earned-values using the concept of multi-objective modelling approach. Since technicians are expected to carry out routine and stochastic maintenance work, we consider these workloads as constraints. The influence of training, fatigue and experiential knowledge of technicians on workload management was considered. These workloads were combined with maintenance policy in optimising reliability, productivity and earned-values using the goal programming approach. Practical datasets were utilised in studying the applicability of the proposed model in practice. It was observed that our model was able to generate information that practicing maintenance engineers can apply in making more informed decisions on technicians' management.

  14. Pharmacy technician involvement in community pharmacy medication therapy management.

    Science.gov (United States)

    Lengel, Matthew; Kuhn, Catherine H; Worley, Marcia; Wehr, Allison M; McAuley, James W

    To assess the impact of technician involvement on the completion of medication therapy management (MTM) services in a community pharmacy setting and to describe pharmacists' and technicians' perceptions of technician involvement in MTM-related tasks and their satisfaction with the technician's role in MTM. Prospective observational study. In the fall of 2015, pharmacists and selected technicians from 32 grocery store-based community pharmacies were trained to use technicians within MTM services. Completed MTM claims were evaluated at all pharmacies for 3 months before training and 3 months after training. An electronic survey, developed with the use of competencies taught in the training and relevant published literature, was distributed via e-mail to trained employees 3 months after training. The total number of completed MTM claims at the 32 pharmacy sites was higher during the posttraining time period (2687 claims) versus the pretraining period (1735 claims). Of the 182 trained participants, 112 (61.5%) completed the survey. Overall, perceived technician involvement was lower than expected. However, identifying MTM opportunities was the most commonly reported technician MTM task, with 62.5% of technicians and 47.2% of pharmacists reporting technician involvement. Nearly one-half of technicians (42.5%) and pharmacists (44.0%) agreed or strongly agreed they were satisfied with the technician's role in MTM services, and 40.0% of technicians agreed that they were more satisfied with their work in the pharmacy after involvement in MTM. Three months after initial training of technicians in MTM, participation of technicians was lower than expected. However, the technicians involved most often reported identifying MTM opportunities for pharmacists, which may be a focus for future technician trainings. In addition, technician involvement in MTM services may increase satisfaction with many aspects of work for actively involved technicians. Copyright © 2018 American

  15. Development of a Training Program for Commercial Building Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Rinholm, Rod

    2013-05-31

    This project focused on developing and deploying a comprehensive program of 22 training modules, including certification requirements, and accreditation standards for commercial building technicians, to help achieve the full savings potential of energy efficient buildings, equipment, and systems. This curriculum extended the currently available commercial building technician programs -- training a labor force in a growing market area focused on energy efficiency. The program helps to remove a major market impediment to low energy/zero energy commercial building system acceptance, namely a lack of operating personnel capable of handling more complex high efficiency systems. The project developed a training curriculum for commercial building technicians, with particular focus on high-efficiency building technology, and systems. In Phase 1, the project team worked collaboratively in developing a draft training syllabus to address project objectives. The team identified energy efficiency knowledge gaps in existing programs and plans and plans to address the gaps with either modified or new curricula. In Phase 2, appropriate training materials were developed to meet project objectives. This material was developed for alternative modes of delivery, including classroom lecture materials, e-learning elements, video segments, exercises, and hands-on training elements. A Certification and Accreditation Plan and a Commercialization and Sustainability Plan were also investigated and developed. The Project Management Plan was updated quarterly and provided direction on the management approaches used to accomplish the expected project objectives. GTI project management practices tightly coordinate project activities using management controls to deliver optimal customer value. The project management practices include clear scope definition, schedule/budget tracking, risk/issue resolution and team coordination.

  16. Rural emergency medical technician pre-hospital electrocardiogram transmission.

    Science.gov (United States)

    Powell, A M; Halon, J M; Nelson, J

    2014-01-01

    Emergent care of the acute heart attack patient continues to be at the forefront of quality and cost reduction strategies throughout the healthcare industry. Although the average cardiac door-to-balloon (D2B) times have decreased substantially over the past few years, there are still vast disparities found in D2B times in populations that reside in rural areas. Such disparities are mostly related to prolonged travel time and subsequent delays in cardiac catherization lab team activation. Urban ambulance companies that are routinely staffed with paramedic level providers have been successful in the implementation of pre-hospital 12-lead electrocardiogram (ECG) protocols as a strategy to reduce D2B times. The authors sought to evaluate the evidence related to the risk and benefits associated with the replication of an ECG transmission protocol in a small rural emergency medical service. The latter is staffed with emergency medical technician-basics (EMT-B), emergency medical technician-advanced (EMT-A), and emergency medical technician-intermediate (EMT-I) level. The evidence reviewed was limited to studies with relevant data regarding the challenges and complexities of the ECG transmission process, the difficulties associated with ECG transmission in rural settings, and ECG transmission outcomes by provider level. The evidence supports additional research to further evaluate the feasibility of ECG transmission at the non-paramedic level. Multiple variables must be investigated including equipment cost, utilization, and rural transmission capabilities. Clearly, pre-hospital ECG transmission and early activation of the cardiac catheterization laboratory are critical components to successfully decreasing D2B times.

  17. IAEA Technical Co-operation activities: Asia and the Pacific. Workshop on training nuclear laboratory technicians

    International Nuclear Information System (INIS)

    Roeed, S.S.

    1976-01-01

    The workshop was held to exchange information on existing facilities and programmes in Asia and the Pacific for training nuclear laboratory technicians, to identify future training needs and to assess the need for IAEA's involvement in this field. As the participants outlined the requirements for nuclear laboratory technician training and the facilities available in their respective countries, it became evident that, in addition to the training of radioisotope laboratory technicians, they also wished to review the need for technician training for the operation of nuclear power plants and industrial application of atomic energy. The terms of reference of the workshop were extended accordingly. The opening address by Chang Suk Lee, the Korean Vice Minister of Science and Technology, noted the valuable contribution to quality control and other industrial uses that nuclear techniques have made in his country. He also reviewed the application of nuclear techniques in Korean agriculture and medicine. The participants explored various forms of co-operation that could be established between countries of the region. Exchange programmes, not only for students but also for expert teachers, and the exchange or loan of equipment were suggested. It was felt that some generalized training courses could be organized on a regional basis, and two countries advocated the setting up of a regional training centre. One suggestion was to arrange regional training courses in special fields that would move from one country to another. The need was felt for periodic regional meetings on training methods, course content and other questions relating to training of laboratory technicians. The IAEA was requested to act as a clearinghouse for information on available training facilities in the region and to advise on the curricula for technician training courses. The Agency was also asked to organize short courses for the training of instructors of technicians in the various fields of atomic

  18. Pneumoconiosis and exposures of dental laboratory technicians

    International Nuclear Information System (INIS)

    Rom, W.N.; Lockey, J.E.; Lee, J.S.; Kimball, A.C.; Bang, K.M.; Leaman, H.; Johns, R.E. Jr.; Perrota, D.; Gibbons, H.L.

    1984-01-01

    One hundred and seventy-eight dental laboratory technicians and 69 non-exposed controls participated in an epidemiological respiratory study. Eight technicians who had a mean of 28 years grinding nonprecious metal alloys were diagnosed as having a simple pneumoconiosis by chest radiograph. Mean values for per cent predicted FVC and FEV1 were reduced among male nonsmoker technicians compared to male nonsmoker controls; after controlling for age, there was also a reduction in spirometry with increasing work-years. An industrial hygiene survey was conducted in 13 laboratories randomly selected from 42 laboratories stratified by size and type of operation in the Salt Lake City, Utah metropolitan area. Personal exposures to beryllium and cobalt exceeded the Threshold Limit Values (TLVs) in one laboratory. Occupational exposures in dental laboratories need to be controlled to prevent beryllium-related lung disorders as well as simple pneumoconiosis

  19. Preparing technicians for photonics industries and organizations

    Science.gov (United States)

    Souders, John; Hull, Dan

    2012-10-01

    U.S. photonics organizations need about 800 new photonics technicians each year. Thirty-one community and technical colleges have approximately 700 students enrolled in photonics related programs; about 275 of them complete their coursework and enter the workforce each year. A disparity exists between the demand and supply of qualified photonics technicians in the U.S. OP-TEC, the National Center for Optics and Photonics Education is a consortium of seven colleges, under the leadership of the University of Central Florida, and sponsored by NSF. OP-TEC's mission is to increase the quantity and quality of photonics technicians prepared at two-year colleges. OP-TEC maintains the National Photonics Skill Standards for Technicians, provides curriculum models, teaching materials, faculty training/professional development and planning services to strengthen existing college photonics programs and to attract and support new ones. OP-TEC is converting its text materials to E-Books to support students in technical programs. Through OP-TEC's recruitment efforts 84 additional colleges are interested in initiating new photonics programs. The OP-TEC Photonics College Network (OPCN) consists of 28 colleges that are currently providing photonics education. This fall OPCN will lead an additional national effort to further educate employed photonics technicians through on-line courses, complemented by lab experiences at nearby colleges. OP-TEC is expanding its outreach to photonics employers and colleges by regionalizing its approach to offering its services. OP-TEC is also planning to develop new curricula and instructional materials for AAS programs to prepare Precision Optics Technicians. This paper will detail OP-TEC's work with particular emphases on its materials and services.

  20. CERN's Technician Training Experience notches up another success!

    CERN Multimedia

    Stephanie Hills

    2015-01-01

    The programme was set up almost three years ago to help address a Europe-wide shortage of highly skilled technicians, with the participants gaining valuable skills and experience in an international environment. It’s clear that the programme works: some of the technician fellows who have taken part are being snapped up by major science projects and the high-tech industry.   Going underground: Fay Chicken at work in ATLAS. Fay Chicken (see UK news from CERN 59) has just accepted a job offer from the European Spallation Source in Sweden, where she will be working in the detector development team: “I’m also going to be setting up a new workshop where prototype detectors will be built. When I went to Lund, I was shown a big, empty room – it’s up to me to equip it!” This level of responsibility is a big step up for Fay, but there is no doubt that her time at CERN has both built her confidence to take on the role, and convinced ESS th...

  1. Guidelines for training and qualification of radiological protection technicians

    International Nuclear Information System (INIS)

    1987-08-01

    These guidelines, used in combination with plant-specific job analysis, provide the framework for a training and qualification program for radiological protection technicians at nuclear power plants. Radiological protection technicians are defined as those individuals, both plant and contractor, who will be engaged in the evaluation of radiological conditions in the nuclear plant and the implementation of the necessary radiological safety measures as they apply to nuclear plant workers and members of the general public. An important aspect of this work is recognizing and handling unusual situations involving radioactivity, including incidents related to degraded core conditions. These guidelines incorporate the results of an industry-wide job analysis and task analysis (JTA) combined with industry operating experience review. However, the industry-wide analyses did not identify all important academic and fundamental knowledge and skills. Further in-depth analysis by subject matter experts produced additional knowledge and skills that were added to these guidelines. All utilities should use these guidelines in conjunction with plant-specific and industry-wide JTA results to develop or validate their radiological protection technician training program. Plant-specific information should be used to establish appropriate training program content. This plant-specific information should reflect unique job duties, equipment, operating experience, and trainee entry-level qualifications. Revisions to these guidelines should be reviewed for applicability and incorporated into the training program using each utility's training system development (TSD) procedures. Plant-specific job analysis and task analysis data is essential to the development of performance-based training programs. These analyses are particularly useful in selecting tasks for training and in developing on-the-job training (OJT), laboratory training, and mock-up training. Qualification programs based on these

  2. Embedded vision equipment of industrial robot for inline detection of product errors by clustering–classification algorithms

    Directory of Open Access Journals (Sweden)

    Kamil Zidek

    2016-10-01

    Full Text Available The article deals with the design of embedded vision equipment of industrial robots for inline diagnosis of product error during manipulation process. The vision equipment can be attached to the end effector of robots or manipulators, and it provides an image snapshot of part surface before grasp, searches for error during manipulation, and separates products with error from the next operation of manufacturing. The new approach is a methodology based on machine teaching for the automated identification, localization, and diagnosis of systematic errors in products of high-volume production. To achieve this, we used two main data mining algorithms: clustering for accumulation of similar errors and classification methods for the prediction of any new error to proposed class. The presented methodology consists of three separate processing levels: image acquisition for fail parameterization, data clustering for categorizing errors to separate classes, and new pattern prediction with a proposed class model. We choose main representatives of clustering algorithms, for example, K-mean from quantization of vectors, fast library for approximate nearest neighbor from hierarchical clustering, and density-based spatial clustering of applications with noise from algorithm based on the density of the data. For machine learning, we selected six major algorithms of classification: support vector machines, normal Bayesian classifier, K-nearest neighbor, gradient boosted trees, random trees, and neural networks. The selected algorithms were compared for speed and reliability and tested on two platforms: desktop-based computer system and embedded system based on System on Chip (SoC with vision equipment.

  3. Training courses for radiological technicians: radiation protection of the patient and control of image quality

    International Nuclear Information System (INIS)

    Mateus Yoshimura, Elisabeth; Costa, Paulo Roberto; Furquim, Tania Aparecida; Freitas, Marcelo Baptista de; Valente, Marcelo; Cerri, Giovanni Guido

    2008-01-01

    Full text: As in other countries, life expectancy is increasing in Brazil, and the number of radiological examinations tends to increase. Old equipment and high technology ones cohabit, radiology technicians are not well prepared to conduct practices, images and doses to patients are not optimized. Digital techniques that began to be introduced in the last years are also an important issue, because, as it is possible to modify the image digitally, there is less concern about the choice of equipment parameters that produce the best-image/lowest-dose compromise. Pediatric radiology, CT and fluoroscopy require attention too, as they are of dosimetric interest or because the patient ages imply higher risks or because the techniques deliver higher doses than the conventional ones. In our opinion, the most important role that we can play is educating and forming people to work in this area: training programs and refreshing courses are a way of facing the problem. This way, we are organizing, in a technical cooperation with IAEA, two training courses in quality assurance and radiation protection in radiology, one designed to physicists (60 h), and the radiological technicians (40 h). An important cooperation with a paediatric and a general hospital made it possible to offer courses with 50% practical lessons, performed both in the University and in hospital equipment. Both courses cover a basic Radiation Physics program, radiation protection, image formation and quality control in conventional and digital equipment, and patient dosimetry. Equipment donated by IAEA facilitate the practical QA and dosimetry lessons. The rationale of our project is making it sustainable through the formation of physicists that will go on in the education process of technicians in technical schools. We present the results of the first two courses (physicists and technicians), considering the selection process, the development of the activities, and the assessment both of the students enrolled

  4. So You Want to Train Solar Technicians.

    Science.gov (United States)

    Ensign, M. Dale; Richins, Michael Paul

    1978-01-01

    Considers the role of solar energy in meeting the nation's energy requirements and the future needs for solar technicians and mechanics. Discusses the precautions community colleges must take in training these workers, to ensure that the demand be met without flooding the job market. (MB)

  5. Section 609 Technician Training and Certification Programs

    Science.gov (United States)

    EPA-approved programs for technicians who service motor vehicle air conditioning (MVAC) systems. Any person who repairs or services a MVAC system for consideration must be certified under section 609 of the Clean Air Act by an EPA-approved program.

  6. Medical Laboratory Technician--Microbiology (AFSC 90470).

    Science.gov (United States)

    Thompson, Joselyn H.

    This four-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for medical laboratory technicians. Covered in the individual volumes are laboratory procedures in clinical bacteriology (the history of bacteriology; aseptic techniques and sterilization procedures; bacterial morphology and…

  7. NASDA technician test real-time radiation monitoring device

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  8. [Emergency Medical Technician profile in Spain].

    Science.gov (United States)

    Martínez-Isasi, Santiago; Rodríguez-Lorenzo, María José; Vázquez-Santamariña, David; Abella-Lorenzo, Javier; Castro Dios, Diana Josefa; Fernández García, Daniel

    2017-12-11

    The emergency medical technician plays a fundamental role and is the most important figure quantitatively in pre-hospital emergencies. The aim was to asses the socio-demographic, work-related, health characteristics and technical skills of an Emergency Medical Technician in Spain. Cross-sectional descriptive study. An ad hoc questionnaire was managed using Google Docs® that was delivered between April-June 2014 via email and social networks. A total of 705 questionnaires were collected. Statistical analysis was performed with SPSS ® 20.0 Windows version. A significance level p≤0.05 was used for all analyzes. The data analyzed show that the profile of the Emergency Medical Technician in Spain is an 39 year-old man, married or living as a couple and has a child. The average BMI is 27 kg/m2, does regular exercise, does not smoke. His seniority in the company is 10 years and has the Medium Cycle of Emergency Medical Technician. The analysis for gender shows that men have an average of 40, an average BMI of 27, 5 kg/m2 and work in an advanced life support unit; while women have an average of 36,5 years, an average BMI of 24,7 kg/m2, mainly work in Basic Life Support Unit and her seniority in the company is 6,76 years. Emergency Medical Technician profile is a overweight men, who refer to practise regular exercise, his seniority in the company is 10 years and is in possession of CMTES; differences were observed according to gender in BMI, resource where they perform their work, seniority and age.

  9. Procedure and equipment for the separation of isotopes for deuterium upgrading and for the production of heavy water

    International Nuclear Information System (INIS)

    Schoell, M.

    1981-01-01

    The invention concerns a simple procedure for the separation of isotopes for the enrichment of deuterium and for the production of heavy water as well as the equipment necessary for carrying out the process. Methane is conducted over bacterial cultures oxidizing methane to water and carbon dioxide. An enrichment of deuterium takes place in non-oxidized methane. The bacterial cultures are placed on carriers that are arranged in oxidation columns as baffle plates. Several oxidation towers of this kind can be arranged in series. (orig./RW) [de

  10. Comparing Burnout Across Emergency Physicians, Nurses, Technicians, and Health Information Technicians Working for the Same Organization

    OpenAIRE

    Schooley, Benjamin; Hikmet, Neset; Tarcan, Menderes; Yorgancioglu, Gamze

    2016-01-01

    Abstract Studies on the topic of burnout measure the effects of emotional exhaustion (EE), depersonalization (DP) (negative or cynical attitudes toward work), and reduced sense of personal accomplishment (PA). While the prevalence of burnout in practicing emergency medicine (EM) professionals has been studied, little is known of the prevalence and factors across physicians, nurses, technicians, and health information technicians working for the same institution. The aim of this study was to a...

  11. 77 FR 31742 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2012-05-30

    ... product is prescribed, no manufacturer may make any representation with respect to water usage of such... or plastic plate that requires the testing laboratory to adapt its test depending on the specific...

  12. Is the European medical products authorization regulation equipped to cope with the challenges of nanomedicines?

    NARCIS (Netherlands)

    Dorbeck-Jung, Barbel R.; Chowdhury, Nupur; Chowdhury, Nupur

    2011-01-01

    This article analyses the emerging European regulatory activities in relation to nanopharmaceuticals. The central question is whether the regulatory responses are appropriate to cope with the regulatory problems nanomedicinal development is posing. The article explores whether the medical product

  13. 76 FR 68785 - Certain Communications Equipment, Components Thereof, and Products Containing the Same, Including...

    Science.gov (United States)

    2011-11-07

    ... complaint names as respondents Cisco Systems, Inc. of San Jose, CA; Cisco Consumer Products LLC of Irvine, CA; Cisco Systems International B.V. of Amsterdam, Netherlands; Cisco-Linksys LLC of Irvine, CA...

  14. 46 CFR 160.151-39 - Training of servicing technicians.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Training of servicing technicians. 160.151-39 Section...-39 Training of servicing technicians. (a) The training program for certification of servicing technicians must include— (1) Training and practice in packing an inflatable liferaft, repairing buoyancy...

  15. 5 CFR 842.210 - Military reserve technicians.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Military reserve technicians. 842.210 Section 842.210 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... reserve technicians. (a) A military reserve technician as defined in 5 U.S.C. 8401(30) who is separated...

  16. 40 CFR 1068.425 - What happens if one of my production-line engines/equipment exceeds the emission standards?

    Science.gov (United States)

    2010-07-01

    ... FOR ENGINE PROGRAMS Selective Enforcement Auditing § 1068.425 What happens if one of my production... engine/equipment to show it complies with all emission standards. (2) Include in your written report a...

  17. Expanded access to naloxone among firefighters, police officers, and emergency medical technicians in Massachusetts.

    Science.gov (United States)

    Davis, Corey S; Ruiz, Sarah; Glynn, Patrick; Picariello, Gerald; Walley, Alexander Y

    2014-08-01

    Naloxone is a medication that reverses respiratory depression from opioid overdose if given in time. Paramedics routinely administer naloxone to opioid overdose victims in the prehospital setting, and many states are moving to increase access to the medication. Several jurisdictions have expanded naloxone administration authority to nonparamedic first responders, and others are considering that step. We report here on policy change in Massachusetts, where several communities have equipped emergency medical technicians, law enforcement officers, and firefighters with naloxone.

  18. ANALISIS TOTAL PRODUCTIVE MAINTENANCE DENGAN METODE OVERALL EQUIPMENT EFFECTIVENESS DAN FUZZY FAILURE MODE AND EFFECTS ANALYSIS

    Directory of Open Access Journals (Sweden)

    Supriyadi Supriyadi

    2017-11-01

    Full Text Available Ash Handling System merupakan suatu bagian dari pembangkit listrik tenaga uap dengan bahan bakar batu bara yang berfungsi untuk menyalurkan limbah pembuangan sisa hasil proses pembakaran batu bara pada boiler. Sisa pembakaran terbagi menjadi fly ash dan bottom ash. Untuk sisa pembakaran fly ash akan disalurkan menuju ke Electrostatic Precipitator untuk ditangkap  dengan metode corona dan ditransfer menuju penampungan fly ash dengan cara dimampatkan bersama udara dari kompresor yang melalui pipa-pipa dan tabung transporter. Sedangkan untuk sisa pembakaran bottom ash akan disalurkan dengan alat yang disebut SSC (Submerged Scraper Conveyor. Gangguan pada SSC dapat terjadi mulai dari belt putus, masalah pada penggerak, hingga masalah pada kelistrikan dan instrumennya. Penelitian ini bertujuan untuk mengetahui nilai OEE, mengetahui dampak gangguan belt sobek, mengetahui penyebab terjadinya belt conveyor sobek dan melakukan estimasi hasil perbaikan dari sisi biaya. Penelitian ini menggunakan metode Overall Equipment Effectiveness (OEE dan Fuzzy Failure Mode and Effects Analysis. Hasil penelitian menunjukkan bahwa rata-rata nilai OEE pada tahun 2015 sekitar 52,05%, masih di bawah standar nilai OEE sebesar 85%. Penyebab utamanya adalah adanya gangguan belt sobek karena gesekan belt dengan support return ketika belt conveyor mengalami jogging yang berdampak pada terganggunya penyaluran abu. Modifikasi dapat menghindari kerugian perusahaan sebesar Rp. 582.548.800,00.

  19. Production Decision Based on Discounted Price and Delivery Frequency for Garment Original Equipment Manufacturer with Constrained Capacity

    Institute of Scientific and Technical Information of China (English)

    HUO Yanfang; GU Yajie; HAN Lin; WANG Xize

    2017-01-01

    Original equipment manufacturers (OEM) have never been so important and powerful as it is today in garment manufacturing industry.The OEM supplier's production decisions always have a great impact on the market performance and the profits of a garment brand manufacturer.With constrained capacity and multiply buyers,how to make reasonable production decisions is an urgent problem for OEM suppliers.A price discount model with a single OEM supplier and two buyers is proposed to deal with the problem.Based on this model,the OEM supplier could satisfy buyers' demands and guarantee their profits as well through adjusting price and delivery frequency.A numerical example validates the validity of the model.

  20. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-02-21

    ... Prototype testing.... Manufacturers must obtain Units with rated All tests use the Units with rated (160.151... Liferafts Prototype testing.... Existing Certificates of No cost or benefit as All tests use the Costs of... designs, overseeing prototype construction, witnessing prototype testing, and monitoring production of the...

  1. 77 FR 35299 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2012-06-13

    ... Conservation Program for Consumer Products Other Than Automobiles,\\2\\ a program covering most major household... polluting than sources that must be used during peak demand times. The utilities indicated that a survey... customarily treated as confidential within the industry; (3) whether the information is generally known by or...

  2. 76 FR 51281 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2011-08-18

    ... standards, DOE divides covered products into classes based on the type of energy used, their size or... often receive considerable attention when they are introduced, over time, public comments tend to focus... methodologies and results of fuel switching more explicit in all rulemakings in which fuel switching might occur...

  3. New Balancing Equipment for Mass Production of Small and Medium-Sized Electrical Machines

    DEFF Research Database (Denmark)

    Argeseanu, Alin; Ritchie, Ewen; Leban, Krisztina Monika

    2010-01-01

    The level of vibration and noise is an important feature. It is good practice to explain the significance of the indicators of the quality of electrical machines. The mass production of small and medium-sized electrical machines demands speed (short typical measurement time), reliability...

  4. 77 FR 53234 - Certain Communication Equipment, Components Thereof, and Products Containing the Same, Including...

    Science.gov (United States)

    2012-08-31

    ... respondents, including Avaya of Basking Ridge, New Jersey; Cisco Consumer Products LLC of Irvine, California, Cisco Systems International B.V. of the Netherlands, Cisco-Linksys LLC of Irvine, California (collectively, ``Cisco''); Hewlett-Packard Co. (``HP'') of Palo Alto, California; and Extreme Networks, Inc...

  5. 76 FR 76436 - Certain Communication Equipment, Components Thereof, and Products Containing the Same, Including...

    Science.gov (United States)

    2011-12-07

    ... AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a...: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134. Cisco Consumer Products LLC, 120 Theory... CH, Amsterdam, Netherlands. Cisco-Linksys LLC, 121 Theory Drive, Irvine, CA 92617. Hewlett-Packard Co...

  6. Design of data acquisition system ZOH production process equipment of ZBS (zircon based sulfate)

    International Nuclear Information System (INIS)

    Moch Rosyid; Tunjung Indrati Y

    2013-01-01

    Design of data acquisition system of ZOH maker unit from ZBS has performed. Design is done as a follow-up of The Design Flow stirred tank reactor (RATB) ZOH Making of ZBS is equipped with a data acquisition system. The design of the system is going to work based on constants or parameters that have been previously calculated. Design method begins with understanding the process description of ZBS ZOH continuous basis, identify the parameters to be observed. Description of the process need to know to determine the actuator is used, as for these parameters are used to determine the sensor to be used. The parameter are the detection of NH 4 OH and ZBS reserves the feeder tank, flow rate ZBS and NH 4 OH, the temperature inside RATB, RATB and pH , the produced flow rate of ZOH. Based on the calculation, in order to get the results needed ZOH ZBS will flow into the reactor at the rate of 10 ml/min simultaneously with NH 4 OH with discharge flow 6.1 ml/min into the RATB 3 liters volume. When the volume reaches half tank RATB then start heating is turned on while the constant feed flow. Conditions of pH and temperature on the RATB always monitored by setting point pH at 10 while setting point temperature of 90°C. Monitoring parameters require gauge/transducer or a particular sensor. The study on the obtained results in the form of a flow chart design controller when controlling the process, when read and transmit data, and display the resulting data acquisition process parameters on the screen according to the parameters that was planned. (author)

  7. Job Satisfaction among Turkish Business Aviation Technicians

    Directory of Open Access Journals (Sweden)

    Tevfik Uyar

    2013-09-01

    Full Text Available The most applicable models in safety management put the human factors, employers’ attitudes and behaviors at the center. This study reports an investigation of job satisfaction among business aviation technicians. A demographic information form and Job Satisfaction Survey (JSS were used to collect data from 44 individuals. Data was analyzed using ANOVA and Student’s t-test. Our results show that there is significant difference in total job satisfaction levels with regard to marital status while other personal factors are not related to the total job satisfaction levels. However several sub dimensions of job satisfaction are affected by the workers’ military or civilian origin, their training background, types of companies they work in or their license category. No difference is found in age and position groups. Secondly, study shows that technicians are the most satisfied from the nature of their work, while they are the least satisfied by operational procedures.

  8. 40 CFR 745.90 - Renovator certification and dust sampling technician certification.

    Science.gov (United States)

    2010-07-01

    ... sampling technician certification. 745.90 Section 745.90 Protection of Environment ENVIRONMENTAL PROTECTION... technician certification. (a) Renovator certification and dust sampling technician certification. (1) To become a certified renovator or certified dust sampling technician, an individual must successfully...

  9. Cooperative educational project for optical technicians utilizing amateur telescope making

    Science.gov (United States)

    Williamson, Ray

    2004-01-01

    In the modern optical shop, technicians are typically skilled machine operators who work on only one phase of the manufacture for each and every component. The product is designed, specified, methodized, scheduled and integrated by people off the shop floor. Even at the component level, the people inside the shop usually see only one stage of completion. In an effort to make the relevance of their work visible; to demonstrate competence to their peers; to gain appreciation for the work of others; and to give them a meaningful connection with the functions of optical systems, I created "The Telescope Project" for my former employer. I invited those interested to participate in an after-hours, partially subsidized project to build telescopes for themselves. The ground-rules included that we would all make the same design (thus practicing consensus and configuration management); that we would all work on every phase (thus learning from each other); and that we would obtain our parts by random lot at the end (thus making quality assurance a personal issue). In the process the participating technicians learned about optical theory, design, tolerancing, negotiation, scheduling, purchasing, fabrication, coating and assembly. They developed an appreciation for each other's contributions and a broader perspective on the consequences of their actions. In the end, each obtained a high-quality telescope for his or her personal use. Several developed an abiding love for astronomy. The project generated much interest from technicians who didn"t initially choose to participate. In this paper I describe the project in detail.

  10. Reticle inspection equipment productivity increase using SEMI specification for reticle and pod management

    Science.gov (United States)

    Taylor, Ron; Downey, Jack; Wood, Jeffrey; Lin, Yen-Hung; Bugata, Bharathi; Fan, Dongsheng; Hess, Carl; Wylie, Mark

    2016-10-01

    In this work, the SEMI specification for reticle and pod management (E109) with internal reticle library support has been integrated for the first time on KLA-Tencor's TeronTM and TeraScanTM reticle inspection tools. Manufacturing Execution System scheduling reticle jobs and Automated Material Handling System scheduling to transfer pods simultaneously have also been integrated and tested. GLOBALFOUNDRIES collaboratively worked with KLA-Tencor to successfully implement these capabilities. Both library and non-library scenarios have been demonstrated for comparison in a real production environment resulting in productivity increase of approximately 29% by making use of the library. Reticle re-qualification test cases were used for the comparison in this work.

  11. Innovative Equipment and Production Method for Mixed Fodder in the Conditions of Agricultural Enterprises

    Science.gov (United States)

    Sabiev, U. K.; Demchuk, E. V.; Myalo, V. V.; Soyunov, A. S.

    2017-07-01

    It is recommended to feed the cattle and poultry with grain fodder in the form of feed mixture balanced according to the content. Feeding of grain fodder in the form of stock feed is inefficient and economically unreasonable. The article is devoted to actual problem - the preparation of mixed fodder in the conditions of agricultural enterprises. Review and critical analyses of mixed fodder assemblies and aggregates are given. Structural and technical schemes of small-size mixed fodder aggregate with intensified attachments of vibrating and percussive action for preparation of bulk feed mixture in the conditions of agricultural enterprises were developed. The mixed fodder aggregate for its preparation in the places of direct consumption from own grain fodder production and purchased protein and vitamin supplements is also suggested. Mixed fodder aggregate allows to get prepared mixed fodder of high uniformity at low cost of energy and price of production that is becoming profitable for livestock breeding. Model line-up of suggested mixed fodder aggregate with different productivity both for small and big agricultural enterprises is considered.

  12. Knowledge and attitudes about smoking cessation among pharmacy technicians.

    Science.gov (United States)

    Zillich, Alan J; Aquilino, Mary L; Farris, Karen B

    2004-01-01

    To evaluate the knowledge and attitudes of pharmacy technicians before and after attending a continuing education program about smoking cessation. A pre/post survey of a single group. Two statewide meetings of the Iowa Pharmacy Association. Pharmacy technicians. One 2-hour continuing education (CE) course about smoking cessation for pharmacy technicians. Changes in scores before and after the CE sessions among three domains (knowledge, efficacy, and outcome) of a validated survey instrument. Fifty-one technicians completed both the presession and postsession questionnaire. For the three survey domains, technicians' knowledge (P = .034), efficacy (P < .001), and outcome (P < .001) showed significant improvement between the presession and postsession surveys (Wilcoxon signed rank test). Pharmacy technicians who attended a CE program on smoking cessation improved their knowledge, attitudes, and self-confidence in helping smokers quit. Additional research should be conducted to test the role of pharmacy technicians in smoking cessation promotion.

  13. Recycling-Oriented Product Characterization for Electric and Electronic Equipment as a Tool to Enable Recycling of Critical Metals

    Science.gov (United States)

    Rotter, Vera Susanne; Chancerel, Perrine; Ueberschaar, Maximilian

    To establish a knowledge base for new recycling processes of critical elements, recycling-orientated product characterization for Electric and Electronic Equipment (EEE) can be used as a tool. This paper focuses on necessary data and procedures for a successful characterization and provides information about existing scientific work. The usage of this tool is illustrated for two application: Hard Disk Drives (HDD) and Liquid Crystal Display (LCD) panels. In the first case it could be shown that Neodymium and other Rare Earth Elements are concentrated in magnets (25% by weight) and contribute largely to the end demand of Neodymium. Nevertheless, recycling is limited by the difficult liberation and competing other target metals contained in HDD. In the second case it could be shown that also for this application the usage of Indium is concentrated in LCDs, but unlike in magnets the concentration is lower (200 ppm). The design of LCDs with two glued glass layers and the Indium-Tin-Oxide layer in between make the Indium inaccessible for hydro-metallurgical recovery, the glass content puts energetic limitations on pyro-metallurgical processes. For the future technical development of recycling infrastructure we need an in depth understanding of product design and recycling relevant parameters for product characterization focusing on new target metals. This product-centered approach allows also re-think traditional "design for recycling" approaches.

  14. Increase of the assistancial productivity of the nuclear magnetic resonance equipment TOMIKON BMT 1100

    International Nuclear Information System (INIS)

    Rodriguez, A.; Carbonell, G.; Hernandez, C.

    1992-01-01

    In the present work a revision of the physical parameters which take part in the obtained of the Nuclear Magnetic Resonance (NMR) is carried put. Image is obtained introducing changes on them given in the disminution of the matrix size from 256 x 256 to 128 pixels with the corresponding disminution of FOV in dependence of the analized region, showing theoretical and practically its great importance of the number of possible examination with the resulting augment of the productivity of the method and the possibility to carried out studies on little cooperative patients mantaining an adequate quality and diagnostic information of the images

  15. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M.; Karam Junior, Dib

    2009-01-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  16. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M., E-mail: egauglitz@ipen.b, E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karan@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  17. Implementation of total productive maintenance (TPM to increase overall equipment efficiency of an hotel industry

    Directory of Open Access Journals (Sweden)

    Manjunatha B.

    2018-01-01

    Full Text Available Hotel industries are one of the fastest growing areas in India, which is attracting more number of jobs & tourists. This also results in direct impact on Indian economy. All Hotels comprises a higher element of total working cost and they are a good source of income. Hospitality is one of the most important components of hotel industry. To give a good hospitality in hotels to customers, we need to use different machines in different departments. For example if we take section of housekeeping it consists of different sub departments like Rooms & corridors, Toilets, Linen, Furniture and furnishings, Gardens, Public areas etc. In this connection a small implementation of TPM tool called focused improvement & planned maintenance, implemented in alternative usage of electrical systems (energy conservation. Result showed a very significant improvement in energy saving. By adopting Small changes show a significant improvement in the overall system. It also indicates the dire need of proper industrial tools in hotels. Total Productive Maintenance (TPM is one of the pioneering approaches which can be achieved in above said things [1][2].

  18. Thermal degradation characteristics and products obtained after pyrolysis of specific polymers found in Waste Electrical and Electronic Equipment

    Institute of Scientific and Technical Information of China (English)

    Evangelia C.Vouvoudi; Aristea T.Rousi; Dimitris S.Achilias

    2017-01-01

    Modern societies strongly support the recycling practices over simple waste accumulation due to environmental harm caused.In the framework of sustainable recycling of plastics from WEEE,pyrolysis is proposed here as a means of obtaining secondary value-added products.The aim of this study was to investigate the thermal degradation and the products obtained after pyrolysis of specific polymers found in the plastic part of WEEE,using thermogravimetric analysis and a pyrolizer equipped with a GC/MS.Polymers studied include ABS,HIPS,PC and a blend having a composition similar to that appearing in WEEE.It was found that,PC shows greater heat endurance compared to the other polymers,whereas ABS depolymerizes in three-steps.The existence of several polymers in the blend results in synergistic effects which decrease the onset and final temperature of degradation.Moreover,the fragmentation occurred in the pyrolyzer,at certain temperatures,resulted in a great variety of compounds,depending on the polymer type,such as monomers,aromatic products,phenolic compounds and hydrocarbons.The main conclusion from this investigation is that pyrolysis could be an effective method for the sustainable recycling of the plastic part of WEEE resulting in a mixture of chemicals with varying composition but being excellent to be used as fuel retrieved from secondary recycling sources.

  19. Changing Roles of Librarians and Library Technicians

    Directory of Open Access Journals (Sweden)

    Norene James

    2015-10-01

    Full Text Available What significant changes are librarians and library technicians experiencing in their roles? A survey put forward across Canada to librarians and library technicians addressing this question was conducted in February 2014. Eight hundred eighty-two responses were obtained from librarians, defined as MLIS graduates, and library technicians, defined as graduates from a two-year library diploma program. Respondents needed to have been employed in the last two years in these roles and students of either an MLIS or LIT program were also welcome to participate. The results suggest that both librarians and library technicians perceive their roles as growing in scope and complexity and that the lines of responsibility are blurring. A majority of respondents indicated that they perceive a change in their roles in the past five years and commented on what the perceived changes were. Librarian and library technician roles may be shifting away from what may be viewed as traditional or clearly defined responsibilities and both librarians and library technicians may be taking on new tasks as well as experiencing task overlap. All library staff will need to be fluid, adaptable, and open to change. Library school curricula and workplace training need to incorporate the development of these competencies. Quels sont les changements importants éprouvés par les bibliothécaires et les bibliotechniciens dans leurs rôles? Un sondage mené en février de 2014 a posé cette question aux bibliothécaires et aux bibliotechniciens dans tout le Canada. On a reçu huit-cent quatre-vingt-deux réponses des bibliothécaires, définis comme étant diplômés en MSIB, et les bibliotechniciens, définis comme étant diplômés d’un programme de deux ans en bibliotechnique. Les sondés devaient avoir travaillé au cours des deux dernières années dans ces fonctions et les étudiants d’un programme MSIB ou de bibliothéconomie/ sciences de l’information pouvaient aussi y

  20. Dental technician pneumoconiosis mimicking lung cancer.

    Science.gov (United States)

    Uyar, Meral; Sokucu, Oral; Sanli, Maruf; Filiz, Ayten; Ali Ikidag, Mehmet; Feridun Isik, Ahmet; Bakir, Kemal

    2015-09-01

    A 47-year-old man was referred for assessment of bilateral lymph node enlargement identified on a routine chest radiograph. Positron emission tomography showed high standardized uptake values (SUVmax: 20.5) in right supraclavicular, right intercostal, and multiple mediastinal lymph nodes. Biopsy samples obtained from the right upper and left lower paratracheal nodes by mediastinoscopy revealed granulomatous inflammation. Clinical and laboratory findings indicated a diagnosis of dental technician pneumoconiosis. The patient is alive and well 3 years after diagnosis. This case highlights the importance of obtaining an occupational history.

  1. Mechanical technology for higher engineering technicians

    CERN Document Server

    Black, Peter

    1972-01-01

    Mechanical Technology for Higher Engineering Technicians deals with the mechanics of machines, thermodynamics, and mechanics of fluids. This book presents discussions and examples that deal with the strength of materials, technology of machines, and techniques used by professional engineers. The book explains the strain energy of torsion, coil springs, and the effects of axial load. The author also discusses the forces that produce bending, shearing, and bending combined with direct stress, as well as beams subjected to a uniform bending moment or simply supported beams with concentrated non-c

  2. Microprocessor based systems for the higher technician

    CERN Document Server

    Vears, RE

    2013-01-01

    Microprocessor Based Systems for the Higher Technician provides coverage of the BTEC level 4 unit in Microprocessor Based Systems (syllabus U80/674). This book is composed of 10 chapters and concentrates on the development of 8-bit microcontrollers specifically constructed around the Z80 microprocessor. The design cycle for the development of such a microprocessor based system and the use of a disk-based development system (MDS) as an aid to design are both described in detail. The book deals with the Control Program Monitor (CP/M) operating system and gives background information on file hand

  3. Radiation protection technician job task analysis manual

    International Nuclear Information System (INIS)

    1990-03-01

    This manual was developed to assist all DOE contractors in the design and conduct of job task analysis (JTA) for the radiation protection technician. Experience throughout the nuclear industry and the DOE system has indicated that the quality and efficiency in conducting a JTA at most sites is greatly enhanced by using a generic task list for the position, and clearly written guidelines on the JTA process. This manual is designed to provide this information for personnel to use in developing and conducting site-specific JTAs. (VC)

  4. Productivity in small dairy farms

    International Nuclear Information System (INIS)

    2007-12-01

    Over the past 10 years the IAEA has assisted the Ministerio de Agricultura y Ganaderia de la Republica del Paraguay in the area of animal production, through technical cooperation projects and research programs with emphasis on milk production. This will got the laboratory equipment, provision of materials and chemical reagents, as well as the training of technicians Paraguayans in specialized centers abroad, which enabled techniques used in the RIA and Ultrasound, used to monitor the reproductive and officials artificial insemination of cattle, with the consequent improvement in milk production [es

  5. THE EVALUATION OF EIGHT PILLARS TOTAL PRODUCTIVE MAINTENANCE (TPM IMPLEMENTATION AND THEIR IMPACT ON OVERALL EQUIPMENT EFFECTIVENESS (OEE AND WASTE

    Directory of Open Access Journals (Sweden)

    Herry Agung Prabowo

    2018-02-01

    Full Text Available In this global era where the level of competition is higher, in addition to the influence of the suitable marketing strategy is also required strategy from the side of production/productivity. PT. XYZ is a company engaged in the manufacturing of snacks especially biscuits. The problem that often occurs in this company is the number of biscuits that are not in accordance with the standard and the production does not reach the target set because the machine suddenly breaks down frequently. To overcome the problems PT. XYZ then choose to implement the Total Productive Maintenance (TPM strategy. This study aims to evaluate the implementation of 8 TPM Pillars and measure the effects on manufacturing performance in the form of Overall Equipment Effectiveness (OEE and Waste. This study uses questionnaire-based survey method. The number of samples distributed is 40 units. Which returned and filled 33 questionnaires and which is worth to be processed as many as 30 samples. Then tested the validity and reliability of data using SPSS program. Validity critical value R = 0.361 for n = 30 and error rate 5%. For reliability test, R value = 0.60 was selected. From the validity test, there are 7 items of questions that are not valid so it is not included in the next process. For the reliability test of the questionnaire is quite reliable with the value of Cronbach's alpha of 0.811. From the CFA analysis, only 6 of 8 TPM pillars are significant while for manufacturing performance only OEE variable is significant. Correlation between 8 Pillars of TPM and manufacturing performance is Strong enough with a value of R = 0.862, which also means 74.3% (R2 variable manufacturing performance can be explained/influenced by variable 8 Pillar TPM and 26.7% the rest by other variables.

  6. Can they do it? Comparing the views of pharmacists and technicians to the introduction of an advanced technician role.

    Science.gov (United States)

    Napier, Patti; Norris, Pauline; Green, James; Braund, Rhiannon

    2016-04-01

    This study aimed to investigate the opinions of pharmacists and technicians regarding the ability of New Zealand technicians to take on an advanced checking technician role. A survey was developed to investigate the opinions regarding the introduction of this new role. The questions covered are: perceived ability to take on the role, training requirements and competence. Surveys were sent to pharmacists whose contact details are available for research purposes (n = 2095) and to all pharmacies in New Zealand (both community and hospital) for the attention of technicians (n = 858). The results were analysed using IBM SPSS and thematic analysis of comments was conducted. A total of 1221 surveys were returned (pharmacists = 736 and technicians = 485). The majority of the technicians (83%) believed that 'some' technicians could work in a CT role, compared with 73% of the pharmacists. Over two-thirds (69%) of the technicians felt comfortable checking a prescription at their current level of training compared with 53% of pharmacists. Both groups' comfort increased with further specific training for the technicians. The majority of both of these groups supported the change in roles. Pharmacists were less confident that technicians could take on this role now, but were more comfortable after extra training had been completed. The technicians, however, were confident they could take on this role now but would take on extra training if needed. © 2015 Royal Pharmaceutical Society.

  7. Comparing Burnout Across Emergency Physicians, Nurses, Technicians, and Health Information Technicians Working for the Same Organization.

    Science.gov (United States)

    Schooley, Benjamin; Hikmet, Neset; Tarcan, Menderes; Yorgancioglu, Gamze

    2016-03-01

    Studies on the topic of burnout measure the effects of emotional exhaustion (EE), depersonalization (DP) (negative or cynical attitudes toward work), and reduced sense of personal accomplishment (PA). While the prevalence of burnout in practicing emergency medicine (EM) professionals has been studied, little is known of the prevalence and factors across physicians, nurses, technicians, and health information technicians working for the same institution. The aim of this study was to assess burnout differences across EM professional types.The total population of 250 EM professionals at 2 public urban hospitals in Turkey were surveyed using the Maslach Burnout Inventory and basic social- and work-related demographics. Descriptive statistics, ANOVA, and additional post hoc tests were computed.Findings show that EE and DP scores were high across all occupational groups, while scores on PA were low. There was a statistically significant difference between nurses and medical technicians (P nurses and medical technicians (P Burnout can be high across occupational groups in the emergency department. Burnout is important for EM administrators to assess across human resources. Statistically significant differences across socio-demographic groups vary across occupational groups. However, differences between occupational groups may not be explained effectively by the demographic factors assessed in this or other prior studies. Rather, the factors associated with burnout are incomplete and require further institutional, cultural, and organizational analyses including differentiating between job tasks carried out by each EM job type.

  8. Technicians under the Microscope: The Training and Skills of University Laboratory and Engineering Workshop Technicians

    Science.gov (United States)

    Lewis, Paul A.; Gospel, Howard

    2015-01-01

    The UK government aims to increase both the number, and also the status, of workers with intermediate-level skills, with a view to creating a "modern class of technicians" who can help to bolster economic growth and prosperity. This article considers the prospects for such a policy by focusing on one particular, but neglected, group of…

  9. Preparing technicians for engineering materials technology

    Science.gov (United States)

    Jacobs, James A.; Metzloff, Carlton H.

    1990-01-01

    A long held principle is that for every engineer and scientist there is a need for ten technicians to maximize the efficiency of the technology team for meeting needs of industry and government. Developing an adequate supply of technicians to meet the requirements of the materials related industry will be a challenge and difficult to accomplish. A variety of agencies feel the need and wish to support development of engineering materials technology programs. In a joint effort among Battelle Laboratories, the Department of Energy (DOE) and Northwest College and University Association for Science (NORCUS), the development of an engineering materials technology program for vocational programs and community colleges for the Pacific Northwest Region was recently completed. This effort has implications for a national model. The model Associate of Applied Science degree in Engineering Materials Technology shown provides a general structure. It purposely has course titles which need delimiting while also including a core of courses necessary to develop cognitive, affective and psychomotor skills with the underlining principles of math, science and technology so students have job entry skills, and so that students can learn about and adapt to evolving technology.

  10. Radiological Control Technician: Phase 2, Core/site practical training

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides a description of the guidelines, qualification in radiological instrumentation, qualification in radiological protection, and qualification in emergency preparedness for radiological control technicians

  11. Radiological Control Technician: Phase 1, Site academic training lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides lesson plans for training radiological control technicians. Covered here is basic radiological documentation, counting errors, dosimetry, environmental monitoring, and radiation instruments

  12. PENGUKURAN NILAI OVERALL EQUIPMENT EFFECTIVENESS SEBAGAI DASAR USAHA PERBAIKAN PROSES MANUFAKTUR PADA LINI PRODUKSI (Studi Kasus pada Stamping Production Division Sebuah Industri Otomotif

    Directory of Open Access Journals (Sweden)

    Robby Suhendra

    2005-01-01

    Full Text Available Overall Equipment Effectiveness (OEE is an effectiveness measurement method of equipment utilization in the implementation of Total Productive Maintenance (TPM. The ability of identification in details toward main problem and the cause factors that makes the improvement efforts become more focused is the reason why this method applied comprehensively by all manufacturing companies around the world. Manufacturing process at Stamping Production Division an automotive isdustry still keeps some unrevealed problems. This condition makes the achievement of OEE figure below the target that means production equipments are not utilized optimally yet. The expression of main problem and the cause factors is needed before the company starts some improvement efforts. This research is started by understanding the equipment losses that existed in company. Then, measuring the achievement of OEE figure in one period and through the pareto analysis toward the measurement's results, the main problem and the cause factors are obtained and clearly depicted in cause-and-effect diagram. Abstract in Bahasa Indonesia : Overall Equipment Effectiveness (OEE adalah metode pengukuran efektivitas penggunaan suatu peralatan. OEE dikenal sebagai salah satu aplikasi progam Total Productive Maintenance (TPM. Kemampuan mengidentifikasikan secara jelas akar permasalahan dan faktor penyebabnya sehingga membuat usaha perbaikan menjadi terfokus merupakan faktor utama metode ini diaplikasikan secara menyeluruh oleh banyak perusahaan didunia. Saat ini proses manufaktur di Stamping Production Division sebuah industri otomotif memiliki permasalahan yang belum terungkap jelas. Hal tersebut mengakibatkan penggunaan peralatan yang ada belum optimal. Pengungkapan akar masalah dan faktor penyebabnya diperlukan sebelum perusahaan melakukan usaha perbaikan. Penelitian ini dimulai dengan mengidentifikasi kerugian peralatan (Equipment Losses yang terjadi. Kemudian mengukur pencapaian nilai OEE

  13. O processo de trabalho do técnico em saúde bucal e suas relações com a equipe de saúde bucal na Região Metropolitana da Grande Vitória, Espírito Santo, Brasil Dental hygienist technicians' working process and their relationship with the oral health team in the Metropolitan Region of Vitória, Espírito Santo, Brazil

    Directory of Open Access Journals (Sweden)

    Carolina Dutra Degli Esposti

    2012-06-01

    Full Text Available O objetivo deste estudo é analisar a compreensão dos cirurgiões-dentistas (CDs sobre o processo de trabalho e as relações da equipe de saúde com os Técnicos em Saúde Bucal (TSBs. Em cinco municípios da Região Metropolitana da Grande Vitória (RMGV, Espírito Santo (ES, Brasil, foram selecionados 18 sujeitos, a partir de uma amostra probabilística de 217 CDs que atuavam no Sistema Único de Saúde (SUS. Os sujeitos foram entrevistados a partir de um roteiro-guia semiestruturado, do qual constavam temas relacionados à organização do trabalho na saúde bucal; às atribuições e responsabilidades do TSB; à relação entre o cirurgião-dentista e o TSB; à relação com a equipe de saúde e autonomia do TSB. Os dados foram analisados a partir da Análise de Conteúdo sugerida por Bardin. Constatou-se que os CDs valorizam a importância da participação dos TSBs na reorganização do trabalho odontológico e a construção de uma relação de parceria e cooperação. Contudo, os CDs reconhecem que a relação com os TSBs é prejudicada pela desinformação sobre o processo de trabalho. Além disso, os CDs demonstram receios quanto à possibilidade de os TSBs tornarem-se dentistas práticos e tomarem seu espaço no mercado de trabalho. Também há preocupações sobre a responsabilização legal dos CDs sobre atividades desenvolvidas pelos TSBs.This study aims to assess dentists' understanding about the working process and the relationships of the health team with dental hygienist technicians (DHT. In five cities of the Metropolitan Region of Vitória, State of Espírito Santo, Southeastern Brazil, 18 subjects were selected from a probability sample of 217 dentists that worked in the National Health System. Subjects were interviewed by means of a semi-structured script, which contained topics related to work organization in oral health; roles and responsibilities of the DHT; relationship between the dentist and the DHT; DHT

  14. Methods for training radiochemical technicians at ORNL

    International Nuclear Information System (INIS)

    Parrott, J.R.; Nicol, R.G.

    The training of personnel to carry out radiochemical operations at ORNL is a formidable and recurrent task since programs are constantly shifting. It is essential that provisions be made for the routine retraining of these personnel if they are to make effective contributions on a continuing basis. Training methods are described that have emerged as a result of thirty years experience in a variety of radiochemical pilot-plant programs. Emphasis is placed on training programs for technicians for the 233 U Processing Facility since essentially all aspects of radiochemical operations are encountered in this facility. These programs have included operations performed in glove boxes, hot-cell manipulator work handling high-neutron-emitting isotopes, and the entire spectrum of remote solvent extraction operations. (U.S.)

  15. A System Approach to Navy Medical Education and Training. Appendix 8 Occupational/Physical Therapy Technician.

    Science.gov (United States)

    1974-08-31

    job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third (instructional) sub...Technician 8494 Physical Therapy Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical...IGIVE ICE PACK TREATMENT 9 IAPPLY WET COMPRESSESISOAKSIPACKS I 10 IGIVE INFRARED TREATMENT 11 IGIVE ULTRAVIOLET TREATMENT 12 EXPLAIN UVL THERAPY

  16. Veterinary Technician Program Director Leadership Style and Program Success

    Science.gov (United States)

    Renda-Francis, Lori A.

    2012-01-01

    Program directors of American Veterinary Medical Association (AVMA) accredited veterinary technician programs may have little or no training in leadership. The need for program directors of AVMA-accredited veterinary technician programs to understand how leadership traits may have an impact on student success is often overlooked. The purpose of…

  17. Coordinating technician allocation and maintenance routing for offshore wind farms

    NARCIS (Netherlands)

    Schrotenboer, Albert H.; uit het Broek, Michiel A. J.; Jargalsaikhan, Bolor; Roodbergen, Kees Jan

    2018-01-01

    A maintenance activity at offshore wind farms requires a combination of technicians with different skills. At an operational level, it is important to fully utilize and coordinate technicians in order to increase efficiency of the short-term maintenance planning. In this paper, we investigate

  18. Pneumoconiosis and respiratory problems in dental laboratory technicians: Analysis of 893 dental technicians

    Directory of Open Access Journals (Sweden)

    Dilek Ergün

    2014-10-01

    Full Text Available Objectives: To explore the rate of pneumoconiosis in dental technicians (DTP and to evaluate the risk factors. Material and Methods: Data of 893 dental technicians, who were admitted to our hospital in the period January 2007–May 2012, from 170 dental laboratories were retrospectively examined. Demographic data, respiratory symptoms, smoking status, work duration, working fields, exposure to sandblasting, physical examination findings, chest radiographs, pulmonary function tests and high-resolution computed tomography results were evaluated. Results: Dental technicians’ pneumoconiosis rate was 10.1% among 893 cases. The disease was more common among males and in those exposed to sandblasting who had 77-fold higher risk of DTP. The highest profusion subcategory was 3/+ (according to the International Labour Organization (ILO 2011 standards and the large opacity rate was 13.3%. Conclusions: To the best of our knowledge, it was the largest DTP case series (N = 893/90 in the literature in English. Health screenings should be performed regularly for the early diagnosis of pneumoconiosis, which is an important occupational disease for dental technicians.

  19. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  20. Contributions to the research programs in nuclear and industrial electronics, domestic production of instrumentation, safety and control systems and equipment for nuclear reactors and auxiliary installations

    International Nuclear Information System (INIS)

    Talpariu, C; Talpariu, J.; Matei, C.

    2001-01-01

    Domestic production of component system and equipment for the control and safety of nuclear facilities was one of the priority objective of the Nuclear Research Institute Pitesti. The problems addressed were particularly related to design and production of analog and digital equipment for measurements, triggering and display of the values of process parameters as well as to regulating complex functions of this equipment. Associated to this effort were the research works concerning: - reliability and in-service life-time of the electronic components and equipment in the safety and control systems for nuclear processes; - radiation endurance of industrial electronic components; utilization of whirling currents in calandria tube testing; - expert systems and applications in nuclear reactor control and safety; design and testing methods of process real time software packages for safety in control critical systems for nuclear domain. There are presented characteristics of the following equipment: 1. amplifier for ionization chambers with triggering comparator circuits for the CANDU 600 reactor shut down system; 2. amplifier for ionization chambers without triggering comparator circuits for power regulating system; 3. safety and regulating computerized system for C9 and C5 cans; 4. acquisition system for dosimetric data in nuclear facilities; 5. program able digital comparator for the reactor shut down system; 6. stationary gamma areal monitors for CANDU 600 reactors and other nuclear facilities

  1. Advancing the role of the pharmacy technician: A systematic review.

    Science.gov (United States)

    Mattingly, Ashlee N; Mattingly, T Joseph

    To summarize the findings of a literature search on advancing the role of pharmacy technicians, including the types of training identified and the potential costs and benefits to both the technician and the pharmacy. A literature search of Scopus, Embase, and Medline was conducted on January 11, 2017. Original research, research reports, case studies, or association reports were included for review. Articles were considered to be relevant based on identification of an advanced pharmacy technician role or addressing additional training/education for technician functions. A standard data extraction form was used to collect study authors, article title, year published, journal title, study design, brief description of methods, primary outcome measures, advanced technician roles identified, additional education or training addressed, and additional costs and benefits identified in each article. A total of 33 articles were included for full review and data extraction. Study design varied, with 17 (52%) quantitative, 1 (3%) qualitative, 5 (15%) mixed-method, and 10 (30%) case study designs. Seventeen (52%) of the studies included were published after 2006. The mechanism of training was primarily through supervised on-the-job training, allowing technicians to assume administrative-based positions that facilitated a pharmacist-led clinical service, with either the pharmacist or the pharmacy receiving the greatest benefits. Although the literature supports technicians performing advanced roles in the pharmacy, resulting in either improved patient outcomes or opportunities for pharmacists to engage in additional clinical services, the benefits to the technician were primarily indirect, such as an increase in job satisfaction or a more desirable work schedule. If a technician is to take on additional roles that require completion of a formalized training or educational program, benefits that are more tangible may help to inspire technicians to pursue these roles. Copyright

  2. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  3. Improving job satisfaction and enlarging the role of technicians.

    Science.gov (United States)

    Spooner, S H; Britton, M E; Erskine, L M; Verschoor, B A; Williams, P A

    1991-01-01

    The process used in preparing this administrative report provided the means of documenting departmental support of technician task expansion, cost benefits, increased availability of professional time, and the need for a dynamic department. Some of the benefits to St. Luke's Regional Medical Center and its Pharmacy Department were an increase in technician job satisfaction, improved quality of patient care attributable to the increased scope of pharmacy service, and up to 8554 hours per year of professional time available for more clinically oriented responsibilities. If technician turnover were decreased by half, technician pricing errors eliminated, and technicians assumed the identified technical tasks, potential monetary benefits could be as much as +116,900 per year. The departmental cost of implementing these recommendations would be an additional 4.16 technician FTEs, and the professional time for training, supervising, and coordinating technicians and functions. These recommendations were well received by pharmacy administration, and the committee was asked to develop a list of priorities and an implementation plan for administrative approval.

  4. Californium-252 Program Equipment Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chattin, Fred Rhea [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Kenton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ezold, Julie G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-01

    To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

  5. Enactment of mandatory pharmacy technician certification in Kansas.

    Science.gov (United States)

    Lucas, Amber; Massey, Lindsay; Gill, Taylor; Burger, Gregory; Little, Jeff D

    2016-02-01

    The successful enactment of mandatory pharmacy technician certification in Kansas is described. In 2004, Kansas began requiring registration of all pharmacy technicians with the state board of pharmacy. Registration identified individuals working as pharmacy technicians but did not require any specific education or certification. In September 2012, the Kansas Board of Pharmacy created a task force of key stakeholders including pharmacists from multiple areas of practice, the University of Kansas School of Pharmacy, organizational leaders from the Kansas Council of Health-System Pharmacists (KCHP) and Kansas Pharmacists Association, and professional lobbyists. The goals of this task force were to research practices of technician certification in other states and to make recommendations to the state board of pharmacy on how Kansas could accomplish mandatory technician certification. The task force outlined the steps needed to achieve legislation that could be supported by the members. These topics included the creation of a technician trainee category, grandfathering certain technicians who had been practicing for a designated period of time, state board-approved exemptions, training requirements, age and education requirements, continuing-education requirements, and pharmacist:technician ratio. The recommendations were finalized at the August 2013 Kansas Pharmacy Summit, and the proposed legislation was introduced and passed during the 2014 legislative session. KCHP members learned many valuable lessons about advocacy and the legislative process with this initiative, including building relationships, working with legislators, and working with other professional organizations. The formation of a task force led to the successful passage of a bill granting the Kansas Board of Pharmacy the authority to issue regulations regarding mandatory pharmacy technician certification. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  6. The role of the pharmacy technician in the skill-mixed district nursing team.

    Science.gov (United States)

    McGraw, Caroline; Coleman, Bridget; Ashman, Lea; Hayes, Sarah

    2012-09-01

    Registered nurses in the district nursing service delegate a broad range of medication administration activities to healthcare assistants. Although healthcare assistants have provided extra capacity, not all activities are suitable for delegation to unregulated practitioners. At the same time, their competency assessment is often patient-specific and demands significant registered nursing input. The purpose of this 6-month pilot programme was to test the premise that the employment of a pharmacy technician in the district nursing service would enhance productivity levels and deliver cost savings. Activities delegated included the administration of oral tablets and subcutaneous insulin and low molecular weight heparin injections. The evaluation found that the introduction of the pharmacy technician was associated with neither enhanced productivity nor more than modest cost savings. However, role redesign is a long-term activity and their role could be built on with further competency analysis.

  7. Flow Cytometry Technician | Center for Cancer Research

    Science.gov (United States)

    PROGRAM DESCRIPTION The Basic Science Program (BSP) pursues independent, multidisciplinary research in basic and applied molecular biology, immunology, retrovirology, cancer biology, and human genetics. Research efforts and support are an integral part of the Center for Cancer Research (CCR) at the Frederick National Laboratory for Cancer Research (FNLCR). KEY ROLES/RESPONSIBILITIES The Flow Cytometry Core (Flow Core) of the Cancer and Inflammation Program (CIP) is a service core which supports the research efforts of the CCR by providing expertise in the field of flow cytometry (using analyzers and sorters) with the goal of gaining a more thorough understanding of the biology of cancer and cancer cells. The Flow Core provides service to 12-15 CIP laboratories and more than 22 non-CIP laboratories. Flow core staff provide technical advice on the experimental design of applications, which include immunological phenotyping, cell function assays, and cell cycle analysis. Work is performed per customer requirements, and no independent research is involved. The Flow Cytometry Technician will be responsible for: Monitor performance of and maintain high dimensional flow cytometer analyzers and cell sorters Operate high dimensional flow cytometer analyzers and cell sorters Monitoring lab supply levels and order lab supplies, perform various record keeping responsibilities Assist in the training of scientific end users on the use of flow cytometry in their research, as well as how to operate and troubleshoot the bench-top analyzer instruments Experience with sterile technique and tissue culture

  8. Time-series product and substance flow analyses of end-of-life electrical and electronic equipment in China

    International Nuclear Information System (INIS)

    Habuer,; Nakatani, Jun; Moriguchi, Yuichi

    2014-01-01

    Highlights: • We estimate the possession and obsolescence of household appliances (HAs) in China. • Over 4.8–5.1 billion units of major HAs will be discarded in the next 20 years. • We calculate the amounts of substances contained in end-of-life (EoL) TV sets. • Less common metals will tend to decrease in content in generation of EoL TV sets. • Precious metals will tend to increase in content in EoL TV sets in 2015–2030. - Abstract: Given the amounts of end-of-life electrical and electronic equipment (EoL-EEE) being generated and their contents of both harmful and valuable materials, the EoL-EEE issue should be regarded not only as an emerging environmental problem but also as a resource management strategy in China. At present, in order to provide the basis for managing EoL-EEE at both product and substance levels in China, it is necessary to carry out a quantitative analysis on EoL-EEE and to determine how much of it will be generated and how much materials and substances it contains. In this study, the possession and obsolescence amounts of five types of household appliance (HA) including television (TV) sets and the amounts of substances contained in EoL TV sets were estimated using time-series product flow analysis (PFA) and substance flow analysis (SFA). The results of PFA indicated that the total possession amounts of those five types of HAs will exceed 3.1 billion units in 2030, which will be two times higher than those in 2010. In addition, it was estimated that cumulatively over 4.8–5.1 billion units of these five types of EoL HA would be obsoleted between 2010–2030. The results of SFA on TV sets indicated that the generated amounts of most of the less common metals and a part of common metals such as copper (Cu) would tend to decrease, whereas those of other common metals such as iron (Fe) as well as precious metals would tend to increase in EoL TV sets in 2015–2030. The results of this study provide a quantitative basis for helping

  9. Time-series product and substance flow analyses of end-of-life electrical and electronic equipment in China

    Energy Technology Data Exchange (ETDEWEB)

    Habuer,, E-mail: habuer@env.t.u-tokyo.ac.jp; Nakatani, Jun; Moriguchi, Yuichi

    2014-02-15

    Highlights: • We estimate the possession and obsolescence of household appliances (HAs) in China. • Over 4.8–5.1 billion units of major HAs will be discarded in the next 20 years. • We calculate the amounts of substances contained in end-of-life (EoL) TV sets. • Less common metals will tend to decrease in content in generation of EoL TV sets. • Precious metals will tend to increase in content in EoL TV sets in 2015–2030. - Abstract: Given the amounts of end-of-life electrical and electronic equipment (EoL-EEE) being generated and their contents of both harmful and valuable materials, the EoL-EEE issue should be regarded not only as an emerging environmental problem but also as a resource management strategy in China. At present, in order to provide the basis for managing EoL-EEE at both product and substance levels in China, it is necessary to carry out a quantitative analysis on EoL-EEE and to determine how much of it will be generated and how much materials and substances it contains. In this study, the possession and obsolescence amounts of five types of household appliance (HA) including television (TV) sets and the amounts of substances contained in EoL TV sets were estimated using time-series product flow analysis (PFA) and substance flow analysis (SFA). The results of PFA indicated that the total possession amounts of those five types of HAs will exceed 3.1 billion units in 2030, which will be two times higher than those in 2010. In addition, it was estimated that cumulatively over 4.8–5.1 billion units of these five types of EoL HA would be obsoleted between 2010–2030. The results of SFA on TV sets indicated that the generated amounts of most of the less common metals and a part of common metals such as copper (Cu) would tend to decrease, whereas those of other common metals such as iron (Fe) as well as precious metals would tend to increase in EoL TV sets in 2015–2030. The results of this study provide a quantitative basis for helping

  10. Optimization of technological planning of the equipment in innovative project of modernization of machine-building production

    Directory of Open Access Journals (Sweden)

    Nasibullin D.R.

    2016-11-01

    Full Text Available this article describes the ways to improve the automated system of technological preparation of manufacturing. The method for optimizing the planning of technological equipment based on the use of artificial neural networks was developed for the automated system of technological preparation of manufacturing.

  11. DOD Recovery personnel and NASA technicians inspect Friendship 7 spacecraft

    Science.gov (United States)

    1964-01-01

    Department of Defense Recovery personnel and spacecraft technicians from NASA adn McDonnell Aircraft Corp., inspect Astronaut John Glenn's Mercury spacecraft, Friendship 7, following its return to Cape Canaveral after recovery in the Atlantic Ocean.

  12. Service Offering at Electrical Equipment Manufacturers

    Directory of Open Access Journals (Sweden)

    Lucie Kaňovská

    2015-09-01

    Full Text Available Purpose of the article: The aim of the paper is to uncover ways of managing service offering provided by electrical equipment manufactures in the Czech Republic. The segment is extremely important for Czech industry nowadays, especially because of many companies being subcontractors for the car industry and mechanical engineering. The producers of electric equipment comply with the Czech industry classification CZ-NACE 27. Methodology/methods: The questionnaire in the form of the Likert scale was prepared to gather information about customer services. The respondents were usually directors or managers, e.g. employees with high competencies of knowing customer services in this particular market. The total of 22 companies were included in the survey. Research was focused on the following industries classifications belonging to CZ-NACE 27: CZ-NACE 27, CZ-NACE 271 and CZ-NACE 273. According to Czech Statistical Office the total number of companies belonging to these 3 segments is 136. It means 16,2% companies belonging to CZ-NACE 27 participated in our research. Basic statistical methods were used to analyse the complete database. Scientific aim: The paper deals with the problem of service offering provided by today’s manufacturers. Global understanding of services that manufacturers really develop, sell, deliver and manage is still limited. Findings: Managing service offering provided by today‘s manufacturers shows that 1 Manufacturers not offer only tangible products, but also wide range of services and even information and support. 2 New products are not designed only according to company technicians, but also according to their customers. Their products and services are developed, tested and improved according to their needs. 3 Services provide complex customer care from time product selection to its end. Conclusions: Manufacturers of tangible products need to enlarge their product offering to be able to satisfy customers. Therefore

  13. 9 CFR 327.8 - Import products; equipment and means of conveyance used in handling to be maintained in sanitary...

    Science.gov (United States)

    2010-01-01

    ... and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION... other means of conveyance transporting any product to the United States, and all trucks, chutes...

  14. The role of the Senior Technician in Nursing as a response to the new model of research training

    Directory of Open Access Journals (Sweden)

    Lola Rosario Altamirano-Baquerizo

    2017-04-01

    Full Text Available This work is based on the recognition of the training needs presented by the students of the Higher Nursing Technician career of the Bolivarian Technological Institute of Technology, since it is presented as a regularity that research training is fundamentally associated with the search for bibliographic information And not as a tool for solving professional problems, together with the completion of the degree project. Therefore, it has as its objective the proposal of reflections of pedagogical nature that allow to understand the proposed model in the research training of the Higher Technician in Nursing in the Ecuadorian context. This result is a product of doctoral research.

  15. 24 CFR 291.530 - Eligible firefighter/emergency medical technicians.

    Science.gov (United States)

    2010-04-01

    ... medical technicians. 291.530 Section 291.530 Housing and Urban Development Regulations Relating to Housing... medical technicians. A person qualifies as a firefighter/emergency medical technician for the purposes of... technician by a fire department or emergency medical services responder unit of the federal government, a...

  16. Chemistry technician performance evaluation program Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Shawver, J.M.

    1992-01-01

    The Arizona Nuclear Power Project (ANPP), a three-reactor site located 50 miles west of Phoenix, Arizona, has developed and implemented a program for evaluating individual chemistry technician analytical performance on a routine basis. About 45 chemistry technicians are employed at the site, 15 at each operating unit. The technicians routinely perform trace level analyses for impurities of concern to PWRs. Each month a set of blind samples is provided by an outside vendor. The blind samples contain 16 parameters which are matrixed to approximate the PWR's primary and secondary cycles. Nine technicians receive the samples, three from each operating unit, and perform the required analyses. Acceptance criteria for successful performance on the blind parameters is based on the values found in the Institute of Nuclear Power Operations (INPO) Document 83-016, Revision 2, August 1989, Chemistry Quality Control Program. The goal of the program is to have each technician demonstrate acceptable performance on each of 16 analytical parameters. On completion of each monthly set, a summary report of all of the analytical results for the sample set is prepared. From the summary report, analytical bias can be detected, technician performance is documented, and overall laboratory performance can be evaluated. The program has been very successful at satisfying the INPO requirement that the analytical performance of each individual technician should be checked on at least a six-month frequency for all important parameters measured. This paper describes the program as implemented at the Palo Verde Nuclear Generating Station and provides a summary report and trend and bias graphs for illustrative purposes

  17. Low cost solar array project production process and equipment task: A Module Experimental Process System Development Unit (MEPSDU)

    Science.gov (United States)

    1981-01-01

    Several major modifications were made to the design presented at the PDR. The frame was deleted in favor of a "frameless" design which will provide a substantially improved cell packing factor. Potential shaded cell damage resulting from operation into a short circuit can be eliminated by a change in the cell series/parallel electrical interconnect configuration. The baseline process sequence defined for the MEPSON was refined and equipment design and specification work was completed. SAMICS cost analysis work accelerated, format A's were prepared and computer simulations completed. Design work on the automated cell interconnect station was focused on bond technique selection experiments.

  18. Customer familiarity with new industrial product technology and its influence on adoption: The case of De Beers diamond extraction equipment

    Directory of Open Access Journals (Sweden)

    Nabbie, A.

    2013-05-01

    Full Text Available An investigation was conducted into the influence of industry customers familiarity with new technology on their decisions when purchasing discontinuous industrial products. This was done in the context where the supplier and customer organisations are entities in the same company. Even in this favourable context, continuous products remained successful despite a better solution being available. Literature on this close type of relationship is sparse, mostly because information on such internal processes is generally regarded as competitive. The case investigated was the DebTech division of De Beers, and their experience with products that they design and manufacture for the global diamond mining industry. Product developer and customer data from applicable projects was analysed, and interviews and observations were conducted. The results indicate that familiarity with the product technology favourably influences perceptions of newness, safety, and the ease of integration of a product. Familiarity increases customers propensity to recommend and purchase new-technology products.

  19. Production and installation of equipments for radiation-induced graft polymerization in liquid phase and dipping techniques

    International Nuclear Information System (INIS)

    Seko, Noriaki; Kasai, Noboru; Tamada, Masao; Hasegawa, Shin; Katakai, Akio; Sugo, Takanobu

    2005-01-01

    Fibrous adsorbent which is synthesized by radiation induced graft polymerization on the trunk polymers such as polymer nonwoven fabrics and woven cloths exhibits an excellent selective adsorption against heavy metal ions and toxic gases at extremely low concentrations. Two equipments were installed to synthesize the metal-ion and gas adsorbents by means of the radiation-induced graft polymerization in the liquid phase and the dipping, respectively. In the reation chamber of the liquid phase reactor, the oxygen decreased to 100 ppm. The inside temperature was elevated at 80C. These characteristics satisfied the specification. The fabric transport can regulate the rate in the range from 1 to 10 m/min. The reactor for the dip grafting could reduce the inside oxygen to 100ppm and inside temperature could reach to 80C, also. The transport system is stable during the dip grafting reaction. The grafting of glycidyl methacrylate was carried out as a characteristic test. The degree of grafting was controlled in the range of 40-70%. The both equipments can graft the trunk polymer, 2000mm in maximum width and 1m in maximum diameter. This size is enough for confirmation practical scale synthesis. (author)

  20. Nontraditional roles for certified pharmacy technicians in a pharmaceutical company.

    Science.gov (United States)

    Fung, Stacey M; Gilmour, Christine; McCracken, David; Shane, Korban; Matsuura, Gary

    2006-01-01

    To describe nontraditional roles for Certified Pharmacy Technicians (CPhTs) within pharmaceutical industry. Drug information department within a large biotechnology/pharmaceutical organization. The Medical Communications department within Genentech uses a skills-mix staffing model in which employees with varying educational and training backgrounds work as a team on meeting the informational needs of consumers and health professionals who contact the company. One position within the department is that of Medical Communications Associate, responsible primarily for managing product inquiries. Medical Communications Associates have degrees in life sciences or an equivalent combination of education and experience, including a minimum of 2 years of related experience in the health care industry. Currently, four of the seven Medical Communications Associates in the department are CPhTs. Not applicable. Ability to recruit CPhTs for Medical Communications Associate positions, and job satisfaction of those hired into these positions. Critical basic skills needed for the Medical Communications Associate position include strong computer literacy, ability to multitask, and ability to work in an environment with frequent interruptions. Strong oral and written communications skills, customer service skills, ability to deal with stressful situations, product-specific knowledge, ability to work on a daily basis with Medical Communications Pharmacists, and knowledge of medical terminology are also important. The skills set of CPhTs matches these requirements, as evidenced by the experiences of the four staff members who have worked in the department for a total of 17 person-years. This nontraditional role for CPhTs can be rewarding and beneficial to all, affording an unique opportunity within the pharmaceutical industry. The skill set and experience of CPhTs can be used in the nontraditional pharmacy practice setting of drug information.

  1. Advancing technician practice: Deliberations of a regulatory board.

    Science.gov (United States)

    Adams, Alex J

    2018-01-01

    In 2016, the Idaho State Board of Pharmacy (U.S.) undertook a major rulemaking initiative to advance pharmacy practice by broadening the ability of pharmacists to delegate tasks to pharmacy technicians. The new rules of the Board thus moved the locus of control in technician scope of practice from law to pharmacist delegation. Pharmacist delegation is individualistic and takes into account the individual technician's capabilities, the pharmacist's comfort level, facility policies, and the risk mitigation strategies present at the facility, among other factors. State law limits, by contrast, are rigid and can mean that pharmacists are unable to delegate tasks that are or could otherwise be within the abilities of their technicians. The expanded technician duties are in two domains: 1) medication dispensing support (e.g., tech-check-tech, accepting verbal prescriptions, transferring prescriptions, and performing remote data entry); and 2) technical support for pharmacist clinical services (e.g., administering immunizations). This commentary reviews the evidence behind these expanded duties, as well as the key regulatory decision points for each task. The Board's rules and approach may prove useful to other states and even other governing bodies outside the U.S. as they consider similar issues. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Hematological findings in male x-ray technicians

    International Nuclear Information System (INIS)

    Meo, Sultan A.

    2004-01-01

    In view of the known health hazards of x-ray radiation, this study focuses on the basic hematological parameters: red blood cells (RBCs), white blood cells (WBCs) and platelets count in x-ray technicians. The aim was to identify the affect of x-ray radiation on blood cell counts in x-ray technicians. The present study was conducted in the Department of Physiology, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the year 2002. In this study, a group of 40 apparently healthy male x-ray technicians with age ranging from 25-50-years were recruited. They were matched with another group of 40 apparently healthy control subjects in terms of age, sex and ethnic origin. Both groups met with exclusion criteria as per standard. Red blood cells, WBC and platelets count were performed by using a blood cell auto analyser. The mean value of platelet count was significantly decreased (p<0.01) in x-ray technicians when compared to controls. However, no significant difference was observed in RBC and WBC count between the groups. Radiation causes decreased platelet count. Further, studies are needed to study the long-term effects of x-ray radiation on blood cell count in x-ray technicians. (author)

  3. Validation of the production process of core-equipment HYNIC-Bombesin-Sn; Validacion del proceso de produccion del nucleo-equipo HYNIC-Bombesina-Sn

    Energy Technology Data Exchange (ETDEWEB)

    Rubio C, N I [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2008-07-01

    The validation process is establishing documented evidence that provides a high degree of assurance that a specific process consistently will produce a product that will meet specifications and quality attributes preset and, therefore, ensures the efficiency and effectiveness of a product. The radiopharmaceutical {sup 99m}Tc-HYNlC-Bombesin is part of the gastrin-releasing peptide (GRP) analogues of bombesin that are radiolabelled with technetium 99 metastable for molecular images obtention. Is obtained from freeze-dry formulations kits (core- equipment)) and has reported a very high stability in human serum, specific binding to receptors and rapid internalization. Biodistribution data in mice showed rapid blood clearance with predominant renal excretion and specific binding to tissues with positive response to GRP receptors. According to biokinetics studies performed on patients with breast cancer, breast show a marked asymmetry with increased uptake in neoplastic breast in healthy women and the uptake of radiopharmaceuticals is symmetrical in both breasts. No reported adverse reactions. In this paper, the prospective validation core-equipment HYNlC-Bombesin-Sn, which was shown consistently that the product meets the specifications and quality, attributes to preset from the obtained from the diagnostic radiopharmaceutical third generation: {sup 99m}Tc-HYNlC-Bombesin. The process was successfully validated and thereby ensuring the efficiency and effectiveness of this agent as a preliminary diagnostic for approval to be marketed. (Author)

  4. A production of non-strain spacing of lattice planes measurement equipment and a measurement of general structure material

    International Nuclear Information System (INIS)

    Minakawa, Nobuaki; Moriai, Atsushi; Morii, Yukio

    2001-01-01

    It is necessary to determine Δd/d in the internal stress measurement by the neutron diffraction method. Therefore, in case the non-strain spacing of lattice planes d 0 (hkl) is measured using bulk material, even though it does and attaches in a sample table length or every width and it is performing the diffraction measurement, it is difficult to determine for a true non-strain spacing of lattice planes by a processing strain, the grain-orientation, etc. It is available for the infinite thing spacing of lattice planes near non-strain condition to be measured by doing random rotation for bulk material in a beam center, and measuring an average spacing of lattice planes. Practical non-strain spacing of lattice planes measurement equipment was made, and the measurement was performed about much structure material. (author)

  5. Epidemiology of aplastic anemia in Japanese radiological technicians

    International Nuclear Information System (INIS)

    Kitabatake, Takashi; Watanabe, Tsuyoshi; Saito, Akira; Nakamura, Minoru.

    1976-01-01

    Among Japanese radiological technicians, four deaths from aplastic anemia have been recorded. Based on this fact, some epidemiological considerations are tried. During the period from 1930 to 1960, the population of radiological technicians is estimated to be 74,400 man-years, in which 0.5 aplastic anemias are expected. However actually three died from aplastic anemia. This difference is statistically significant at the 1% level. On the other hand, in the period from 1961 to 1973, the observed value is 1 against 0.7 expected. It is concluded that aplastic anemia had been frequently induced among Japanese radiological technicians in the era when there was much exposure to occupational radiation. (auth.)

  6. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (United States)

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. Radiological Control Technician: Phase 4, Facility practical training attachment

    International Nuclear Information System (INIS)

    1992-10-01

    At DOE sites with more than one facility, and where RCT tasks at each facility may differ, site and facility tasks should be separated. The tasks that are common to all the facilities on the site should be included in Phase II training with the core tasks. Tasks unique to a facility should be added to the training program qualification standard, as an attachment, as Phase IV training. Not all the DOE sites will include Phase IV training in their programs. Phase IV training allows each site to qualify technicians to a select facility. Since the core training for the technicians is standardized, the transfer of technicians between facilities requires that only facility tasks be taught, provided the core qualification is current

  8. ASHP statement on the pharmacy technician's role in pharmacy informatics.

    Science.gov (United States)

    2014-02-01

    The American Society of Health- System Pharmacists (ASHP) believes that specially trained pharmacy technicians can assume important supportive roles in pharmacy informatics. These roles include automation and technology systems management, management of projects, training and education, policy and governance, customer service, charge integrity, and reporting. Such roles require pharmacy technicians to gain expertise in information technology (IT) systems, including knowledge of interfaces, computer management techniques, problem resolution, and database maintenance. This knowledge could be acquired through specialized training or experience in a health science or allied scientific field (e.g., health informatics). With appropriate safeguards and supervision, pharmacy technician informaticists (PTIs) will manage IT processes in health-system pharmacy services, ensuring a safe and efficient medication-use process.

  9. Dental technician pneumoconiosis mimicking pulmonary tuberculosis: a case report.

    Science.gov (United States)

    Tan, Han Loong; Faisal, Mohamed; Soo, Chun Ian; Ban, Andrea Y L; Manap, Roslina Abdul; Hassan, Tidi M

    2016-09-07

    Dental laboratory technicians are at risk of developing occupational respiratory diseases due to exposure to various potentially toxic substances in their working environment. Since 1939, few cases of silicosis among dental technician have been reported. We illustrate a 38 year-old female, who worked in a dental laboratory for 20 years, initially treated as pulmonary tuberculosis and chronic necrotising aspergillosis without much improvement. Computed tomography guided lung biopsy and bronchoscopic transbronchial lung biopsy were performed. Lung tissue biopsies showed presence of refractile dental materials within the areas of histiocyte proliferation. The diagnosis of dental technician pneumoconiosis was obtained and our patient underwent pulmonary rehabilitation. This case highlights the importance of obtaining a detailed occupational history in tuberculosis endemic area, as pulmonary tuberculosis is a great mimicker of other respiratory diseases.

  10. Potentiality Studies of Stainless Steel 304 Material for Production of Medical Equipment using Micro Electrical Discharge Machining (micro-EDM) Analysis and Modeling

    DEFF Research Database (Denmark)

    Puthumana, Govindan

    2016-01-01

    Stainless steel 304 (SS304) is a material widely used for production of medical equipment mainly because of its anti-corrosive properties. It has excellent mechanical properties, strength and reliability because of which it is one of the best materials for fabrication of medical devices. This paper...... and process parameters were developed. Grey relational analysis was used to optimize the micro-EDM quality characteristics, and the highest grey relational grade (GRG) of 0.8021 was obtained at a voltage of 100 V and a capacitance of 0.4 μF....

  11. A System Approach to Navy Medical Education and Training. Appendix 24. Equipment Repair Technician.

    Science.gov (United States)

    1974-08-31

    REIdRT , i- FIFRMN ORG 6Po,. NUMBER ...... ,s / . . .. . CONTRACT Oil GRANT NUMNIER e _ ___ __ _ _ _ _ _ __ _ _ _ _ _ 9 PERFORMING ORGANIZATION NAME...Courses." In this he called for "vigorous and imaginative effort," and an approach "characterized by an organized training program with precise goals and...FOR NON-STANDARD USAGE 30 IFABRICATE WROUGHT METAL FRAMEWORK 31 IDRAW ARCHITECHTURAL FLOOR PLAN FOR CLINIC 32 IBUILD MULTIPLE-PATIENT CARDIAC

  12. Recovery Act: Training Curriculum Development for Building Equipment Technicians, Operators, and Commissioning Agents/Auditors

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, Joseph; Yu, David

    2012-08-04

    This US DOE funded project produced ten advanced energy engineering technology courses where students learn about the latest technologies and practices in the energy industry to reduce energy use in residential, commercial and industrial settings, accounting for over 50% of the world’s energy use. A geothermal and a solar thermal system were installed and commissioned as part of this project, an MATC’s cost share. An innovative intelligent lighting lab was installed, complete with course content as well as innovative academic pathway construction, laddering students from the 2-year technical college to the 4-year engineering school.

  13. Rapid methods for jugular bleeding of dogs requiring one technician.

    Science.gov (United States)

    Frisk, C S; Richardson, M R

    1979-06-01

    Two methods were used to collect blood from the jugular vein of dogs. In both techniques, only one technician was required. A rope with a slip knot was placed around the base of the neck to assist in restraint and act as a tourniquet for the vein. The technician used one hand to restrain the dog by the muzzle and position the head. The other hand was used for collecting the sample. One of the methods could be accomplished with the dog in its cage. The bleeding techniques were rapid, requiring approximately 1 minute per dog.

  14. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    2011-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. Such movements and manipulations are frequently accomplished by means of devices driven by liquids (hydraulics) or air (pneumatics), the subject of this book. Hydraulics and Pneumatics is written by a practicing process control engineer as a guide to the successful operation of hydraulic and pneumatic systems for all engineers and technicians working with them. Keeping mathematics and theory to a minimum, this practical guide is thorough but accessible to technicians without a

  15. Proposed procedure and analysis of results to verify the indicator of the product dose-area in radiology equipment

    International Nuclear Information System (INIS)

    Garcia Marcos, R.; Gallego Franco, P.; Sierra Diaz, F.; Gonzalez Ruiz, C.; Rodriguez Checa, M.; Brasa Estevez, M.; Gomez Calvar, R.

    2013-01-01

    The aim of this work is to establish a procedure to verify the value of the product dose-area showing certain teams of Radiology, with an alternative to the use of external transmission cameras. (Author)

  16. Spouted bed drying of Bauhinia forficata link extract: the effects of feed atomizer position and operating conditions on equipment performance and product properties

    Directory of Open Access Journals (Sweden)

    C. R. F. Souza

    2005-06-01

    Full Text Available In this paper the effects of feed atomizer position and operating conditions on equipment performance (accumulation rate, product recovery, elutriation and thermal efficiency and product properties (moisture content, size distribution, flavonoid degradation and flow properties during spouted bed drying of Bauhinia forficata Link extract are evaluated. The parameters studied were the position of the atomizer system (top spray or bottom spray, the inlet temperature of the spouting gas (80 and 150oC and the feed mass flow rate of concentrated extract relative to the evaporation capacity of the dryer, Ws/Wmax (15 to 100%. Higher accumulation rate values were obtained with the atomizer placed at the bottom of the bed. In this configuration, the accumulation rate increases with the increase in the Ws/Wmax ratio. The best drying performance was obtained for the top spray configuration.

  17. Worst-case study for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagents: Methodology validation of total organic carbon

    International Nuclear Information System (INIS)

    Porto, Luciana Valeria Ferrari Machado

    2015-01-01

    Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called 'worst case', to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99m Tc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case. Worst case product's choice was based on the calculation of an index called 'Worst Case Index' (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated 'worst case' was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu®, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision

  18. Use of automated test equipment and open-quotes paperlessclose quotes process control to implement efficient production of SSC dipole magnets

    International Nuclear Information System (INIS)

    Tobin, T.; Fagan, R.; Mitchell, D.

    1994-01-01

    In an effort to minimize human error and maximize process control and test capabilities during Collider Dipole Magnets (CDM) production, General Dynamics is developing automated test and process control equipment; known as Test ampersand Process Control Modules (TPCM's). When used along with software designed to create open-quotes paperlessclose quotes process control documentation, the system becomes the Test ampersand Process Control System (TPCS). This system simplifies business decisions and eliminates some problems normally associated with process control documentation, while reducing human errors during CDM production. It is also designed to reduce test operator errors normally incurred during test setup and data analysis. The authors present an overview of the TPCS hardware and software being developed at General Dynamics, along with the process control techniques included in TPCS

  19. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: - designing of devices and equipment for experiments in physics, their mechanical construction and assembly. In particular, there are vacuum chambers and installations for HV and UHV; - maintenance and upgrading of the existing installations and equipment in our Institute; - participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and a AO plotter, what allows us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop can offer a wide range of machining and treatment methods with satisfactory tolerances and surface quality. It offers the following possibilities: - turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc-type elements of a diameter up to 600 mm and a length not exceeding 300 mm; - milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm; - grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm; - drilling - holes of a diameter up to 50 mm; - welding - electrical and gas welding, including TIG vacuum-tight welding; - soft and hard soldering; - mechanical works including precision engineering; - plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides; - painting - paint spraying with possibility of using furnace-fred drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop posses CNC milling machine which can be used for machining of work-pieces up to 500 kg

  20. Low cost solar array project production process and equipment task. A Module Experimental Process System Development Unit (MEPSDU)

    Science.gov (United States)

    1981-01-01

    Technical readiness for the production of photovoltaic modules using single crystal silicon dendritic web sheet material is demonstrated by: (1) selection, design and implementation of solar cell and photovoltaic module process sequence in a Module Experimental Process System Development Unit; (2) demonstration runs; (3) passing of acceptance and qualification tests; and (4) achievement of a cost effective module.

  1. 40 CFR 82.40 - Technician training and certification.

    Science.gov (United States)

    2010-07-01

    ... speaking technicians by providing tests in other languages or allowing the use of a translator when taking the test. If a translator is used, the certificate received must indicate that translator assistance.... Each program must provide adequate training, through one or more of the following means: on-the-job...

  2. Technician Training for the Semiconductor Microdevices Industry. Final Report.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    The Center for Occupational Research and Development (CORD) carried out four activities to foster semiconductor manufacturing technician (SMT) training: (1) collaboration with industry experts and educators while developing a curriculum to train SMTs; (2) implementation and testing of the curriculum at a technical college; (3) dissemination of…

  3. The Technician beneath Our Wings, or Is That Blades?

    Science.gov (United States)

    Colony, Lee; Foster, John

    2011-01-01

    Today's trained technicians in alternative energy fields are finding even more career opportunities open to them as the United States and the world turn to green technology to power their homes and businesses. Wisconsin's Gateway Technical College is training workers for green collar careers in geoexchange heating and cooling systems, wind power…

  4. [EEG technician-nurse collaboration during stereo-electroencephalography].

    Science.gov (United States)

    Jomard, Caroline; Benghezal, Mouna; Cheramy, Isabelle; De Beaumont, Ségolène

    2017-01-01

    Drug-resistant epilepsy has significant repercussions on the daily life of children. Surgery may represent a hope. The nurse and the electroencephalogram technician carry out important teamwork during pre-surgical assessment tests and notably the stereo-electroencephalography. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Scheduling technicians and tasks in a telecommunications company

    DEFF Research Database (Denmark)

    Cordeau, J. F.; Laporte, G.; Pasin, F.

    2010-01-01

    This paper proposes a construction heuristic and an adaptive large neighborhood search heuristic for the technician and task scheduling problem arising in a large telecommunications company. This problem was solved within the framework of the 2007 challenge set up by the French Operational Research...

  6. An Integration of Math with Auto Technician Courses

    Science.gov (United States)

    Valenzuela, Hector

    2012-01-01

    This article describes the development of the contextualized math, the course design, student teaching and daily interaction with the students, and the implementation aspects of the research project designed to develop contextualized mathematics and integrate it into the Auto Technician courses. The applied math curriculum was integrated into…

  7. Students as Technicians: Screening Newborns for Cystic Fibrosis

    Science.gov (United States)

    Gusky, Sharon

    2014-01-01

    In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…

  8. Are further education opportunities for emergency care technicians ...

    African Journals Online (AJOL)

    Background. A recent review of emergency care education and training in South Africa resulted in the creation of a new 2-year, 240-credit National Qualifications Framework (NQF) level 6 Emergency Care Technician (ECT) qualification. The National Department of Health (NDoH) view ECTs as 'mid-level workers' in the ...

  9. Technicians dismantle the inner section of L3

    CERN Multimedia

    Laurent Guiraud

    2001-01-01

    The technicians are dismantling the forward tracking chamber located at the heart of the L3 detector. This formed part of the hadronic calorimeter, which is used for measuring particle energies. L3 was an experiment at the LEP collider that ran from 1989 to 2000.

  10. Two technicians apply insulation to S-II second stage

    Science.gov (United States)

    1964-01-01

    Two technicians apply insulation to the outer surface of the S-II second stage booster for the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  11. Fulbright project focuses on rehabilitation technician education and ...

    African Journals Online (AJOL)

    Rehabilitation technician education and physiotherapy practice 272. Fulbright project focuses on ... particularly those qualified to mentor and teach entry-level learners, there are ... to reinforce classroom didactic knowledge as ongoing learning .... utilization of limited resources, and development of linkages with professional ...

  12. Underground coal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2002-12-01

    This paper reports on increasing automation and enhanced productivity on longwalls, new development cutting and bolting technologies and haulage systems. Amongst equipment discussed is DBT's Electra series EL3000 shearer, the Dosco LH1400 roadheader with onboard bolters, and Joy 12 CM30 continuous miners. 4 photos.

  13. Science and engineering technicians in the United States: characteristics of a redefined population, 1972

    International Nuclear Information System (INIS)

    Finn, M.G.

    1978-02-01

    The 1972 redefined population was distributed among 10 technician fields. Approximately 75% of the total were concentrated in four relatively large fields: computer programmers; draftsmen; electrical and electronic technicians; and technicians, other fields. Women accounted for 11% of all technicians. The average age of technicians in 1972 was 37. Whites comprised 94.8% of all technicians, while 3.0% were black. More technicians resided in the middle Atlantic region than in any other region. As a percentage of the civilian labor force, however, technicians were most heavily concentrated in the New England and mountain regions. The educational level of technicians was quite diverse: about one-third had no postsecondary education, about one-sixth had at least a bachelor's degree. About one-half fell somewhere between these extremes. Approximately 68% of all technicians reported some form of supplemental training outside formal educational institutions. This training was quite diverse. In 1972, unemployed technicians totaled 3.2% of the technician labor force. Fourteen percent of technicians reported employment outside their field, and 11% reported employment outside the 10 technician fields that constituted the focus of this report. The median annual earnings of technicians employed full-time in 1971 was approximately $10,400. Private companies employed 71% of the technicians; federal and state governments employed 12.4% and 7.4%, respectively. Most other technicians were employed by local government or nonprofit organizations. Implications for policy and planning are drawn. The statistics presented here indicate that the most commonly used assumptions about education--occupation linkages are grossly oversimplified. 5 figures, 44 tables

  14. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  15. A new standard for multidisciplinary health and safety technicians

    Energy Technology Data Exchange (ETDEWEB)

    Trinoskey, P.A.; Fry, L.A. [Lawrence Livermore National Laboratory, Univ. of California, CA (United States); Egbert, W.F. [Lawrence Livermore National Laboratory, Allied Signal Technical Corporation (United States)

    2000-05-01

    Over the last two decades, a significant trend in health and safety has been toward greater specialization. However, compartmentalization of health and safety disciplines often leads to an inequity in resources, especially when appropriations overemphasize one risk to the detriment of others. For example, overemphasis on radiological safety can create an imbalance in overall worker protection. A multidisciplinary technical can help restore the balance and provide for a healthier and safer work environment. The key advantages of a multidisciplinary health and safety technician include: Broad coverage of the work area by one technician, More diverse use of the technician pool, Better coverage for off-shift or nonstandard hours, Balance of risks because all hazards are considered, Integrated emergency response, Ownership, Less time of identify the correct person with the requisite skills. We have developed a new standard that establishes the training and related qualifications for a multidisciplinary health and safety technician. The areas of training and qualification that are addressed include elements of industrial hygiene, industrial safety, fire protection, electrical safety, construction safety, and radiation safety. The initial core training program ensures that individuals are trained to the performance of requirements of the job. Initial training is in five areas: Fundamentals, Hazard recognition, Hazard assessment, Hazards controls, Hazards minimization. Core training is followed by formal qualification on specific tasks, including ventilation surveys, air monitoring, noise assessments, radiological monitoring, area inspections, work-area setups, and work coverage. The new standard addresses not only training topics and requirements, but also guidance to ensure that performance objectives are met. The standard applies to technicians, supervisors, technologists, and six specialty areas, including academic institutions and decontamination and decommissioning

  16. Experience with a pharmacy technician medication history program.

    Science.gov (United States)

    Cooper, Julie B; Lilliston, Michelle; Brooks, DeAnne; Swords, Bruce

    2014-09-15

    The implementation and outcomes of a pharmacy technician medication history program are described. An interprofessional medication reconciliation team, led by a clinical pharmacist and a clinical nurse specialist, was charged with implementing a new electronic medication reconciliation system to improve compliance with medication reconciliation at discharge and capture compliance-linked reimbursement. The team recommended that the pharmacy department be allocated new pharmacy technician full-time-equivalent positions to assume ownership of the medication history process. Concurrent with the implementation of this program, a medication history standard was developed to define rules for documentation of what a patient reports he or she is actually taking. The standard requires a structured interview with the patient or caregiver and validation with outside sources as indicated to determine which medications to document in the medication history. The standard is based on four medication administration category rules: scheduled, as-needed, short-term, and discontinued medications. The medication history standard forms the core of the medication history technician training and accountability program. Pharmacy technicians are supervised by pharmacists, using a defined accountability plan based on a set of medical staff approved rules for what medications comprise a best possible medication history. Medication history accuracy and completeness rates have been consistently over 90% and rates of provider compliance with medication reconciliation rose from under 20% to 100% since program implementation. A defined medication history based on a medication history standard served as an effective foundation for a pharmacy technician medication history program, which helped improve provider compliance with discharge medication reconciliation. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. A new standard for multidisciplinary health and safety technicians

    International Nuclear Information System (INIS)

    Trinoskey, P.A.; Fry, L.A.; Egbert, W.F.

    2000-01-01

    Over the last two decades, a significant trend in health and safety has been toward greater specialization. However, compartmentalization of health and safety disciplines often leads to an inequity in resources, especially when appropriations overemphasize one risk to the detriment of others. For example, overemphasis on radiological safety can create an imbalance in overall worker protection. A multidisciplinary technical can help restore the balance and provide for a healthier and safer work environment. The key advantages of a multidisciplinary health and safety technician include: Broad coverage of the work area by one technician, More diverse use of the technician pool, Better coverage for off-shift or nonstandard hours, Balance of risks because all hazards are considered, Integrated emergency response, Ownership, Less time of identify the correct person with the requisite skills. We have developed a new standard that establishes the training and related qualifications for a multidisciplinary health and safety technician. The areas of training and qualification that are addressed include elements of industrial hygiene, industrial safety, fire protection, electrical safety, construction safety, and radiation safety. The initial core training program ensures that individuals are trained to the performance of requirements of the job. Initial training is in five areas: Fundamentals, Hazard recognition, Hazard assessment, Hazards controls, Hazards minimization. Core training is followed by formal qualification on specific tasks, including ventilation surveys, air monitoring, noise assessments, radiological monitoring, area inspections, work-area setups, and work coverage. The new standard addresses not only training topics and requirements, but also guidance to ensure that performance objectives are met. The standard applies to technicians, supervisors, technologists, and six specialty areas, including academic institutions and decontamination and decommissioning

  18. Comparative Assessment of Blood Lead Levels of Automobile Technicians in Organised and Roadside Garages in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Abdulsalam Saliu

    2015-01-01

    Full Text Available Occupational exposure to lead is common among automobile technicians and constitutes 0.9% of total global health burden with a majority of cases in developing countries. The aim of this study was to determine and compare the blood lead levels of automobile technicians in roadside and organised garages in Lagos State, Nigeria. This was a comparative cross-sectional study. Data were collected using interviewer-administered questionnaires. Physical examinations were conducted and blood was analysed for lead using atomic spectrophotometery. Statistical analyses were performed to compare the median blood lead levels of each group using the independent sample (Mann-Whitney U test. Seventy-three (40.3% of the organised compared to 59 (34.3% of the roadside groups had high blood lead levels. The organised group had statistically significant higher median blood lead levels of, 66.0 µg/dL than the roadside 43.5 µg/dL (P < 0.05. There was also statistically significant association between high blood lead levels and abnormal discolouration of the mucosa of the mouth in the organised group. Automobile technicians in organised garages in Lagos have higher prevalence of elevated blood lead levels and higher median levels than the roadside group. Preventive strategies against lead exposures should be instituted by the employers and further actions should be taken to minimize exposures, improve work practices, implement engineering controls (e.g., proper ventilation, and ensure the use of personal protective equipment.

  19. How compliant are technicians with universal safety measures in medical laboratories in Croatia?--A pilot study.

    Science.gov (United States)

    Dukic, Kristina; Zoric, Matea; Pozaic, Petra; Starcic, Jelena; Culjak, Marija; Saracevic, Andrea; Miler, Marijana

    2015-01-01

    This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status. An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N=217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants. The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), Plaboratory accreditation status (P=0.081). A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants' age. However, those working in private laboratories adhere more to the code of conduct.

  20. Training nuclear technicians in two-year, post-secondary educational programs

    International Nuclear Information System (INIS)

    Hull, D.M.; Roney, M.W.

    1975-01-01

    An available and economical supply to future manpower requirements for various types of nuclear technicians can be met by developing and/or restructuring two-year, post-secondary programs at local educational institutions. The Technical Education Research Centers program is under contract from the U.S. Office of Education to delineate the job requirements and develop curricula and instructional materials for two-year, post-secondary training of nuclear technicians. Six job categories have been identified along with corresponding tasks which the technician performs. These categories are: Reactor Operator, Nuclear Instrumentation Technician, Nuclear QA/QC Technician, Radiochemistry Technician, Radiation Protection Technician and Nuclear Medicine Technician. For the first five categories curricula have been established, courses have been described, and instructional materials are being written

  1. Essential math and calculations for pharmacy technicians

    CERN Document Server

    Reddy, Indra K

    2003-01-01

    Working with Roman and Arabic NumeralsUsing Fractions and Decimals in Pharmacy MathUsing Ratios, Proportions and Percentages in Dosage CalculationsApplying Systems of MeasurementsInterpreting Medication OrdersIdentifying Prescription Errors and OmissionsWorking with Liquid Dosage FormsWorking with Solid Dosage FormsAdjusting IsotonicityWorking with Buffer and Ionization ValuesDealing with ReconstitutionsDetermining Milliequivalent StrengthsCalculating Caloric Values Determining IV Flow RatesWorking with Insulin and Heparin ProductsAppendices: A: Working with Temperature ConversionsB: Working with Capsule Dosage FormsC: Dealing with Pediatric Dosages D: Understanding Essential Business Math.

  2. A study on the development of curriculum of nuclear technology development for training engineering technicians in nuclear plants

    International Nuclear Information System (INIS)

    Lee, Y.S.; Yoon, S.K.; Lee, C.Y.

    1982-01-01

    In this paper, the development of curriculum was studied for Department of Nuclear Technology. In order to make the students suitable for the job as engineering technicians with both theory and practical technique, the basic education in the field related to nuclear energy was emphasized in designing the curriculum. In addition taking the special situation of our department into consideration, we made it a principle to provide them with practical experiences with on-the-job training for 16 weeks. A model curriculum with syllabuses for major subjects, contents of experiments with lists of equipments, and program of on-the-job-training were suggested. (author)

  3. Equipment Management for Sensor Networks: Linking Physical Infrastructure and Actions to Observational Data

    Science.gov (United States)

    Jones, A. S.; Horsburgh, J. S.; Matos, M.; Caraballo, J.

    2015-12-01

    Networks conducting long term monitoring using in situ sensors need the functionality to track physical equipment as well as deployments, calibrations, and other actions related to site and equipment maintenance. The observational data being generated by sensors are enhanced if direct linkages to equipment details and actions can be made. This type of information is typically recorded in field notebooks or in static files, which are rarely linked to observations in a way that could be used to interpret results. However, the record of field activities is often relevant to analysis or post-processing of the observational data. We have developed an underlying database schema and deployed a web interface for recording and retrieving information on physical infrastructure and related actions for observational networks. The database schema for equipment was designed as an extension to the Observations Data Model 2 (ODM2), a community-developed information model for spatially discrete, feature based earth observations. The core entities of ODM2 describe location, observed variable, and timing of observations, and the equipment extension contains entities to provide additional metadata specific to the inventory of physical infrastructure and associated actions. The schema is implemented in a relational database system for storage and management with an associated web interface. We designed the web-based tools for technicians to enter and query information on the physical equipment and actions such as site visits, equipment deployments, maintenance, and calibrations. These tools were implemented for the iUTAH (innovative Urban Transitions and Aridregion Hydrosustainability) ecohydrologic observatory, and we anticipate that they will be useful for similar large-scale monitoring networks desiring to link observing infrastructure to observational data to increase the quality of sensor-based data products.

  4. Using Overall Equipment Effectiveness indicator to measure the level of planned production time usage of sewing machine

    Directory of Open Access Journals (Sweden)

    Marek Krynke

    2014-12-01

    Full Text Available The chapter presents the results of utilization of the OEE indicator to measure the level of operating time usage of sewing machine production of air bags. The idea of an OEE indictor, which is a key metrics in Total Productive Maintenance (TPM program, is presented. The goals and benefits of its calculation are included. The research object – KL 110 air bags sewing machine - what for the machine is used. The calculation of TPM indicators for the analysed machine is presented. The calculation of TPM indicators was undertaken over a period of six months of the machine’s working time. It was indicated that the overall effectiveness of the machine is at a level of 65,7%, the time losses were 34,3%. Most of the losses were related to low performance. Only Availability indicator reaches a word class level, if other indicators such as Performance, Quality and OEE should be improved, their value should be increased. Activities to improve the effectiveness of the machine utilization were determined.

  5. Determination of Anthracycline Drug Residual in Cleaning Validation Swabs of Stainless-Steel Equipment after Production of Cytostatic Injections Using HPLC Analytical Method

    Directory of Open Access Journals (Sweden)

    Zuzana Slivová

    2015-01-01

    Full Text Available Standard cleaning procedures of production line equipment were verified after manufacture of cytostatic injections containing Anthracycline derivate substance. Residual content of Anthracycline drug substance on stainless-steel equipment surface was determined using swab sampling with a specific HPLC-DAD analysis. The acceptance limit was decided as 200.0 μg/100 cm2. Recovery from the stainless-steel surface was 90.1%. Linearity of the method was observed in the concentration range of 0.155–194 μg/mL when estimated using Zorbax TMS (5 μm, 0.25 m × 4.6 mm ID column at 1.3 mL/min flow rate and 254 nm (DAD 190–600 nm. The mobile phase consisted of lauryl hydrogen sulphate solution (3.7 g/L : methanol : acetonitrile (54 : 16 : 30, v/v/v with pH adjusted to 2.5 using phosphoric acid (85%. The LOD and LOQ for Anthracycline derivate were found to be 0.047 and 0.155 μg/mL, respectively. The method validation confirmed the method provides acceptable degree of selectivity, linearity, accuracy, and precision for the intended purposes.

  6. Methods for training radiochemical technicians at ORNL

    International Nuclear Information System (INIS)

    Parrott, J.R.; Nicol, R.G.

    1975-01-01

    The training of personnel to carry out radiochemical operations at ORNL is a formidable and recurrent task since repetitive, production-type operations are not involved, and programs are constantly shifting. It is essential that provisions be made for the routine retraining of personnel if they are to make effective contributions on a continuing basis. The present training methods have emerged as a result of thirty years experience in a variety of radiochemical pilot-plant programs. These programs have included operations performed in glove boxes, hot-cell manipulator work handling high-neutron-emitting isotopes, and the entire spectrum of remote solvent extraction operations. Present methods of training and the results obtained are summarized

  7. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  8. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  9. 5 CFR 831.306 - Service as a National Guard technician before January 1, 1969.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Service as a National Guard technician... National Guard technician before January 1, 1969. (a) Definitions. In this section—(1) Service as a National Guard technician is service performed under section 709 of title 32, United States Code (or under...

  10. Proceedings of the 18. international symposium on mine planning and equipment selection (MPES 2009) and the 11. international symposium on environmental issues and waste management in energy and mineral production (SWEMP 2009) : mine planning and equipment selection and environmental issues and waste management in energy and mineral production

    International Nuclear Information System (INIS)

    Singhal, R.K.; Mehrotra, A.; Fytas, K.; Ge, H.

    2009-01-01

    This conference focused on the application of innovative technologies to the mineral industries and the development of productive methods for the mining and processing industries. It was attended by participants from North and South America, Europe, Australia, Africa and Asia with backgrounds in computer sciences, mining engineering and research in mineral production. The major topics addressed regarding mine planning and equipment selection included economic and technical feasibility studies; reserve estimation; mine development; design and planning of surface and underground mines; drilling, blasting, tunneling and excavation engineering; mining equipment selection; automation and information technology; maintenance and production management for mines and mining systems; mining in terms of health, safety and the environment; and rock mechanics and geotechnical applications. The topics addressed regarding waste management in energy and mineral production included the environmental impacts of coal-fired power projects; mining and reclamation; water management; social aspects of rehabilitation; sustainable development for mineral and energy industries; remediation of contaminated soil and groundwater; health hazard and safety issues in small-scale mining; environmental issues in surface and underground mining of metalliferous, coal, uranium and industrial minerals; occupational health and safety; control of effluents from mineral processing, metallurgy and chemical plants; emerging technologies for environmental protection; reliability of waste containment structures; and tailings treatment, recycling and disposal. The conference featured 162 presentations, of which 30 have been catalogued separately for inclusion in this database. refs., tabs., figs.

  11. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  12. Compensation of Emergency Medical Technician (EMT)-Basics and Paramedics.

    Science.gov (United States)

    Studnek, Jonathan R

    2016-12-01

    The objective of this paper is to identify factors associated with compensation for Emergency Medical Technician (EMT)-Basics and Paramedics and assess whether these associations have changed over the period 1999-2008. Data obtained from the Longitudinal EMT Attributes and Demographic Study (LEADS) surveys, a mail survey of a random, stratified sample of nationally certified EMT-Basics and Paramedics, were analyzed. For the 1999-2003 period, analyses included all respondents providing Emergency Medical Services (EMS). With the addition of a survey in 2004 about volunteers, it was possible to exclude volunteers from these analyses. Over 60% of EMT-Basics reported being either compensated or noncompensated volunteers in the 2004-2008 period. This was substantially and significantly greater than the proportion of EMT-Paramedic volunteers (Technician (EMT)-Basics and Paramedics. Prehosp Disaster Med. 2016;31(Suppl. 1):s87-s95.

  13. Work group design in pharmacy: the pharmacist-technician team.

    Science.gov (United States)

    Kershaw, B P; Solomon, D K; Zarowitz, B J

    1987-05-01

    The contemporary pharmacy practice manager faces the challenge of designing pharmacy service programs that not only satisfy the needs of the patient, but at the same time satisfy and motivate the pharmacists and technicians who sustain the programs. This research examined the team design, which has been recommended but not fully described in the literature. This application did not explore the full potential of the team design in the hospital pharmacy setting. More study is needed in this area to assess the impact of work group design on the expansion of clinical programs, employee turnover rates, quality and quantity of work produced, and, most important, the impact on job satisfaction enjoyed by pharmacists and technicians.

  14. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  15. Cosmonaut Sergei Krikalev receives assistance from suit technician

    Science.gov (United States)

    1994-01-01

    Sergei Krikalev, alternative mission specialist for STS-63, gets help from Dawn Mays, a Boeing suit technician. The cosmonaut was about to participate in a training session at JSC's Weightless Environment Training Facility (WETF). Wearing the training version of the extravehicular mobility unit (EMU) space suit, weighted to allow neutral buoyancy in the 25 feet deep WETF pool, Krikalev minutes later was underwater simulating a contingency spacewalk, or extravehicular activity (EVA).

  16. Digitizing the Facebow: A Clinician/Technician Communication Tool.

    Science.gov (United States)

    Kalman, Les; Chrapka, Julia; Joseph, Yasmin

    2016-01-01

    Communication between the clinician and the technician has been an ongoing problem in dentistry. To improve the issue, a dental software application has been developed--the Virtual Facebow App. It is an alternative to the traditional analog facebow, used to orient the maxillary cast in mounting. Comparison data of the two methods indicated that the digitized virtual facebow provided increased efficiency in mounting, increased accuracy in occlusion, and lower cost. Occlusal accuracy, lab time, and total time were statistically significant (Ptechnician communication.

  17. Results of the 2015 National Certified Pharmacy Technician Workforce Survey.

    Science.gov (United States)

    Desselle, Shane P; Holmes, Erin R

    2017-07-01

    The results of the 2015 National Certified Pharmacy Technician Workforce Survey are described. A survey was e-mailed to a randomized sample of 5,000 certified pharmacy technicians (CPhTs) throughout the United States, with response reminders employed. Survey items eliciting demographic and work characteristics and work life attitudes were generated from the literature and qualitative interviews. This study aimed to describe job satisfaction, sources of stress, profession and employer commitment, education and training, and reasons for entry into the profession among CPhTs and determine relationships between those variables and CPhTs' level of involvement in various work activities, with particular attention paid to differences in practice setting. Frequency statistics, correlation analysis, and means testing were used to meet study objectives and identify significant differences. A total of 516 CPhTs currently working as a pharmacy technician responded to the survey. The CPhTs reported high levels of involvement in more traditional activities but less involvement in those that involve greater cognitive load. Respondents reported moderate levels of job satisfaction and commitment and somewhat high levels of stress overall. Most CPhTs chose to be a pharmacy technician because they desired to enter a healthcare field and help people and were recruited. CPhTs derived benefit from all aspects of education and training evaluated and most from on-the-job training. Perceived value of education and training was associated with higher satisfaction and commitment and with lower stress. There were a number of differences in these work life attitudes across practice settings and by involvement in various job functions. The results of the survey indicated that job satisfaction and commitment were moderate and that stress levels were somewhat high among CPhTs. There were a number of differences in work life attitudes across practice settings and by involvement in various job

  18. Training needs analysis for engineering technicians in Oman

    Science.gov (United States)

    Al-Mughairi, Abdulkarim Sultan

    This thesis examines the transition from the Omani Colleges of Technology (CT) to employment of its engineering graduates. It arises out of concerns that the transition to the labour market for engineering graduate is problematical. The research was carried out to identify the knowledge, skills, and abilities (KSA) of engineering technicians required in the Omani market place. The aim is to provide local curriculum designers in the Colleges of Technology with sufficient information about the required KSA in order to create and enhance the engineering curriculum so that it has greater capacity to meet the needs of a variety of stakeholders and of employers in particular. This in turn has the potential to bridge the gap between what is presently taught and what the workplace demands. Personnel psychologists identify views concerning the skills that are required for different jobs. One of these is based on the assumption that quite different skills are required in different jobs (SCANS, 1990). This view generates approaches within job analysis: the worker-oriented and the task-oriented approaches. This research uses Position Analysis Questionnaire (PAQ), which is a worker-oriented job analysis instrument, to investigate the KSA required to perform some of the engineering technician jobs in Omani industries. In addition, semi-structured interviews were used to investigate the factors that either hinder or entirely prevent the new graduates from Colleges of Technology from being accepted in the workforce pool. The major research findings concern the dimensions of knowledge, skills, and abilities of six engineering technician job titles and the major factors that hinder or (prevent) the technical college graduates from being accepted in the market place in Oman. These findings would definitely help design better transition route and bridge the gap between the CT technicians engineering programmes and the workplace demands.

  19. Occupational contact dermatitis amongst dentists and dental technicians

    OpenAIRE

    Lugović-Mihić, Liborija; Ferček, Iva; Duvančić, Tomislav; Bulat, Vedrana; Ježovita, Josip; Novak-Bilić, Gaby; Šitum, Mirna

    2016-01-01

    Since the working medical personnel including dentists and dental technicians mainly use their hands, it is understandable that the most common occupational disease amongst medical personnel is contact dermatitis (CD) (80%-90% of cases). Development of occupational CD is caused by contact of the skin with various substances in occupational environment. Occupational etiologic factors for dental personnel are foremost reactions to gloves containing latex, followed by various dental materials...

  20. Investigating laparoscopic psychomotor skills in veterinarians and veterinary technicians.

    Science.gov (United States)

    Kilkenny, Jessica; Santarossa, Amanda; Mrotz, Victoria; Walker, Meagan; Monaghan, Dominique; Singh, Ameet

    2017-04-01

    To determine the influence of age, year of graduation, and video game experience on baseline laparoscopic psychomotor skills. Cross-sectional. Licensed veterinarians (n = 38) and registered veterinary technicians (VTs) (n = 49). A laparoscopic box trainer was set up at the 2016 Ontario Veterinary Medical Association (OVMA) and the 2016 Ontario Association of Veterinary Technicians (OAVT) conferences held in Toronto, Ontario, Canada. Participants volunteered to perform a single repetition of a peg transfer (PT) exercise. Participants were given a short demonstration of the PT task prior to testing. A Spearman's rank correlation (r s ) was used to identify associations between baseline psychomotor skills and self-reported surgical and non-surgical experiences collected via survey. Mann-Whitney U tests were used to compare PT scores in veterinarians and VTs. A P-value of  .05). Veterinary technicians that frequently used chopsticks scored higher than those without chopstick experience (P = .04). Age and year of graduation correlated inversely, while self-reported VG experience correlated positively with laparoscopic psychomotor skills of veterinarians, when assessed on a simulator. The use of chopsticks may contribute to the acquisition of psychomotor skills in VTs. © 2017 The American College of Veterinary Surgeons.

  1. DEGREE OF AWARENESS OF SOFT RELINING MATERIALS BY DENTAL TECHNICIANS

    Directory of Open Access Journals (Sweden)

    Ilian Hristov

    2017-10-01

    Full Text Available The aim of the current investigation is to analyze the dental-technicians’ awareness of the soft relining materials, their characteristics, advantages, shortcomings and methods for relining. Materials and methods: For the purpose of this investigation a standard questionnaire has been presented. A direct survey method, documentary and statistical method, as well as graphical methods, including tables, charts, graphics and figures, were used. Data were analysed with the help of IBM SPSS Statistics (ver. 19. Results: One hundred and eight dental technicians were included in the survey, evenly distributed by gender. Removable and fixed prosthodontics is the most commonly mentioned spheres of dental activities. Almost all included in the investigation point out the laboratory relining method as the most frequently used. Acrylic and silicone SRM are the most used groups of relining materials. Change of colour and hardness are the most frequently noticed shortcomings of these materials. The majority of the dental technicians declare that they have never done replacement of SRM or the relining has lasted more than a year. Discussion: The correlation between the age and the years of labour service among the participants is quite obvious. Most of them start working soon after their graduation. Removable prosthodontics is among the priorities for the majority of the labs. Conclusion: Although their unambiguous advantages, the soft relining materials have lots of shortcomings as well. The major problems are connected with their change of colour and hardness. Nevertheless, the dental technicians find them useful and reliable in overcoming specific prosthetic problems.

  2. Partners in qualified equipment supply

    International Nuclear Information System (INIS)

    Rygg, D.E.; O'Hare, G.J.

    1993-01-01

    Industry initiatives have been taken to improve procurement practices and commercial dedication programs, formation of procurement engineering groups, emphasis on product quality, and increased engineering involvement in procurement and maintenance of qualified equipment. This poses new challenges for many licensees in terms of resources, product knowledge, and access to information normally held proprietary by equipment suppliers. Alternative approaches to future licensee/Westinghouse relationships which will allow licensees to adapt to the changing environment are discussed. 2 figs

  3. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  4. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  5. Ask not what your technician can do for you-ask what you can do for your technician.

    Science.gov (United States)

    Ganderton, L

    2018-04-27

    Historically, the vital roles played by technicians in Higher Education have had little recognition. Job opportunities are often overlooked by those who have no working knowledge of such organisations and poorly defined career pathways mean that it may not be a first choice for well-qualified, ambitious individuals. With just over a third of all Higher Education technicians in the UK now due to retire in the next 10 to 15 years, fundamental changes are needed, both to attract large numbers of people into vacant roles and to retain current technical staff.National initiatives, founded and driven by charitable and professional bodies, are currently working to address the issues of technicians within Higher Education. Organisations have been urged to take action or face potential recruitment difficulties and skills gaps over the coming years. In light of these national campaigns, institutions across the UK are beginning to develop proper structured career pathways, provide professional development and improve recognition for the work of their technical workforce. Whilst these are encouraging signs, only time will tell if enough has been done to raise both the profile and appeal of a technical career in Higher Education.

  6. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453

    International Nuclear Information System (INIS)

    Costa, Rogerio Ferreira da

    2013-01-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  7. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  8. Electronics technician Bill Clark assembling a cannon plug with the help of Jim Lewis

    Science.gov (United States)

    1991-01-01

    There is always something needed for a NASA aircraft before a research flight can take place. This photo shows William J. Clark working on one of those 'somethings' while Jimmie C. Lewis watches ready to help. Working on a research project is a challenge, for there is no set pattern to follow. From the drawings to the final product there are many people who contribute to that final product -- the flight. The electronic technicians in the Instrumentation Laboratory at NASA Ames-Dryden Flight Research Facility are no exception. Bill Clark is busy creating a cannon plug to be used on the CV-990. He is soldering wires in the appropriate order so the plug will transmit electrical currents correctly when installed in the airplane. Jim stands by to give help and support on the project.

  9. Coal mining equipment

    International Nuclear Information System (INIS)

    Stein, R.R.; Martin, T.W.

    1991-01-01

    The word in longwall components is big, and these larger components have price tags to match. The logic behind the greater investment is that it will yield high production rates and good uptime statistics. This is true in most cases. More important than single-shift tonnage records, average shift production continues to climb upwards. This paper reports on the quality, and more significantly, the quantity of service supplied for long-wall equipment, which has reached levels that would have been seen as unachievable when longwall mining was first introduced in the U.S. The school of thought then was that longwall would increase productivity in part by reducing the number of production units and thus reducing the number of personnel employed underground. The expectation of fewer employees turned out to be unrealistic. That was probably one reason that some early attempts to install longwall system looked more like failures than vision of the future

  10. Evaluating the effectiveness of an online medical laboratory technician program.

    Science.gov (United States)

    Hansen-Suchy, Kara

    2011-01-01

    The purpose of this study was to analyze the effectiveness of an online medical laboratory technician program in the academic preparation and development of laboratory professionals. A semi-quantitative comparative research design was used. Several factors were considered in this evaluation. Academic outcomes between online and campus medical laboratory technician (MLT) students was determined by comparing overall and categorical scores on certification exams as well as first time pass rate. Certification exam scores and first time pass rates were also compared to national norms when possible to do so. Demographic data, including age and experience were compared. Additionally, learning styles were assessed to determine if there was a correlation to overall GPA and MLT GPA and if learning styles could be used to predict successful completion of an online Associates of Applied Science. The research was conducted at an academic university located in the mountain west United States. Participants consisted of online and campus students enrolled in a Medical Laboratory Technician program that graduated with their Associate of Applied Science degree between the years 2007-2009. Results of these years were also compared to graduates from 2004-2006 in the same program. Certification performance and first time pass rates were the major outcomes measured. Age and experience were correlated. Online learning styles and GPA were also compared to successful degree completion. The researcher found no significant difference in certification performance with regard to total and categorical scores, and first time pass rates between campus and online MLT students. Online students were slightly older and had more experience working in a laboratory in some capacity. Correlation studies showed significant positive correlation between learning styles, GPA, and successful completion of an Associate of Applied Science degree. When registry scores were compared to the prior cohort of online

  11. Snapshot of cobalt, chromium and nickel exposure in dental technicians.

    Science.gov (United States)

    Kettelarij, Jolinde; Nilsson, Sara; Midander, Klara; Lidén, Carola; Julander, Anneli

    2016-12-01

    It is not fully understood where and how people are exposed to sensitizing metals. Much can be learnt from studying occupational settings where metals are handled. To quantify cobalt (Co), chromium (Cr) and nickel (Ni) exposure on the skin and in the air, and urine levels, in dental technicians working with tools and alloys that may result in skin and respiratory exposure. The metal skin dose was quantified with acid wipe sampling in dental technicians (n = 13). Air exposure was monitored by personal air sampling. Spot urine samples were collected for 24 h. Metals were analysed with inductively coupled plasma mass spectrometry. Before work, Co was detected on the skin of 10 participants (0.00025-0.0039 µg/cm 2 ), and Cr (0.00051-0.011 µg/cm 2 ) and Ni (0.0062-0.15 µg/cm 2 ) on the skin of all participants. After a 2-h period without hand washing, CoCr-exposed participants had more Co on the skin (p = 0.004) than non-CoCr-exposed participants. Co was found in 10 air samples (0.22-155 µg/m 3 ), Cr in nine (0.43-71 µg/m 3 ), and Ni in four (0.48-3.7 µg/m 3 ). Metal urine concentrations were considered to be normal. Dental technicians were exposed to Co, Cr and Ni on the skin and through the air, which was not reflected in the urine concentrations in this study. Cobalt skin doses may potentially elicit allergic contact dermatitis and cause sensitization. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    1991-01-01

    Hydraulics and Pneumatics: A Technician's and Engineer's Guide provides an introduction to the components and operation of a hydraulic or pneumatic system. This book discusses the main advantages and disadvantages of pneumatic or hydraulic systems.Organized into eight chapters, this book begins with an overview of industrial prime movers. This text then examines the three different types of positive displacement pump used in hydraulic systems, namely, gear pumps, vane pumps, and piston pumps. Other chapters consider the pressure in a hydraulic system, which can be quickly and easily controlled

  13. Hazards assessment and technical actions due to the production of pressured hydrogen within a pilot photovoltaic-electrolyser-fuel cell power system for agricultural equipment

    Directory of Open Access Journals (Sweden)

    Simone Pascuzzi

    2016-06-01

    Full Text Available A pilot power system formed by photovoltaic panels, alkaline electrolyser and fuel cell stacks was designed and set up to supply the heating system of an experimental greenhouse. The aim of this paper is to analyse the main safety aspects of this power system connected to the management of the pressured hydrogen, such as the explosion limits of the mixture hydrogen-oxygen, the extension of the danger zone, the protection pressure vessels and the system to make unreactive the plant. The electrolyser unit is the core of this plant and from the safety point of view has been equipped with devices able to highlight the malfunctions before they cause damages. Alarm situations are highlighted and the production process is cut off in safe conditions in the event that the operational parameters have an abnormal deviation from the design values. Also the entire power system has been designed so that any failure to its components does not compromise the workers’ safety even if the risk analysis is in progress because technical operations are being carried out for enhancing the plant functionality, making it more suitable to the designed task of supplying electrically the greenhouse heating system during cold periods. Some experimental data pertinent to the solar radiation and the corresponding hydrogen production rate are also reported. At present it does not exist a well-established safety reference protocol to design the reliability of these types of power plants and then the assumed safety measures even if related to the achieved pilot installation, can represent an original base of reference to set up guidelines for designing the safety of power plants in the future available for agricultural purposes.

  14. Quantitative transfer of Escherichia coli O157:H7 to equipment during small-scale production of fresh-cut leafy greens.

    Science.gov (United States)

    Buchholz, Annemarie L; Davidson, Gordon R; Marks, Bradley P; Todd, Ewen C D; Ryser, Elliot T

    2012-07-01

    Postharvest contamination and subsequent spread of Escherichia coli O157:H7 can occur during shredding, conveying, fluming, and dewatering of fresh-cut leafy greens. This study quantified E. coli O157:H7 transfer from leafy greens to equipment surfaces during simulated small-scale commercial processing. Three to five batches (22.7 kg) of baby spinach, iceberg lettuce, and romaine lettuce were dip inoculated with a four-strain cocktail of avirulent, green fluorescent protein-labeled, ampicillinresistant E. coli O157:H7 to contain ∼10(6), 10(4), and 10(2) CFU/g, and then were processed after 1 h of draining at ∼23°C or 24 h of storage at 4°C. Lettuce was shredded using an Urschel TransSlicer at two different blade and belt speeds to obtain normal (5 by 5 cm) and more finely shredded (0.5 by 5 cm) lettuce. Thereafter, the lettuce was step conveyed to a flume tank and was washed and then dried using a shaker table and centrifugal dryer. Product (25-g) and water (40-ml) samples were collected at various points during processing. After processing, product contact surfaces (100 cm(2)) on the shredder (n = 14), conveyer (n = 8), flume tank (n = 11), shaker table (n = 9), and centrifugal dryer (n = 8) were sampled using one-ply composite tissues. Sample homogenates diluted in phosphate or neutralizing buffer were plated, with or without prior 0.45- m m membrane filtration, on Trypticase soy agar containing 0.6% yeast extract supplemented with 100 ppm of ampicillin to quantify green fluorescent protein-labeled E. coli O157:H7 under UV light. During leafy green processing, ∼90% of the E. coli O157:H7 inoculum transferred to the wash water. After processing, E. coli O157:H7 populations were highest on the conveyor and shredder (Ptransfer.

  15. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  16. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  17. Job analysis of nuclear power reactor health physics technicians

    International Nuclear Information System (INIS)

    Davis, L.T.; Mazour, T.J.; Clark, P.V.; Todd, R.C.; Marotta, F.J.

    1984-06-01

    This report describes a project, an industry-wide Job Analysis of Nuclear Power Reactor Health Physics Technicians (HPTs), conducted by Brookhaven National Laboratory and Analysis and Technology, Inc. to provide the industry with job-performance data that can be used in systematically defining training programs in terms of required job functions responsibilities, and performance standards. The job-analysis methodology is consistent with that used by the Institute of Nuclear Power Operations (INPO) in similar industry-wide projects and includes administration of over 850 job task questionnaires to utility and contractor Health Physics Technicians throughout the country. Data collected includes task performance (difficulty, importance, and frequency) and industry-wide demographics (job levels, experience, education, and training). The results of this project discussed herein include model job descriptions for HPT positions, summaries of HPT experience, education, and training, industry-wide task listings with task-performance characteristics, and recommendations of selected tasks as a basis for HPT training development. Finally, potential future applications of the data base by utility and contractor organizations in training program development and evaluation and personnel qualifications are discussed

  18. A uniform approach for on-site training and qualification of health physics technicians

    International Nuclear Information System (INIS)

    Till, J.E.

    1977-01-01

    Estimates show that in the U.S. approx. 75% of the health physics technicians received their training through courses offered by their employer. The quality and the extent of this training vary considerably among nuclear facilities. This paper describes a uniform approach for on-site training and qualification of health physics technicians applicable to all nuclear facilities. The program consists of four levels of qualification: Health Physics Technician Trainee, Technician I, Technician II and Senior Technician. The training is divided into modules that are composed of formal lectures, practical factors, experience, and a comprehensive examination. The minimum time required from hiring of inexperienced trainees to qualification as Senior Technicians is approx. 24 months. A qualification guide lists each step a technician must complete in the training program and provides documentation which facilitates audits by internal and external groups. Although items in the program would differ between facilities, the program provides specific titles for technicians, based on their training and experience, which would be applicable throughout the nuclear industry. (author)

  19. Role of the chemical engineering technician in applied research related to tritium separation from aqueous effluents

    International Nuclear Information System (INIS)

    Nelson, S.D.

    1978-01-01

    Applied research and development activities related to the removal of tritium from aqueous effluent streams have presented broad opportunities to the chemical engineering technician for professional growth. Technician job activities involve operating complex analytical instrumentation and constructing, maintaining, and operating experimental electrolysis apparatus. The technician is a member of a professional team including scientific, engineering, and other technical personnel and as such is expected to exercise creative thought. Proximity of a large university and availability of formalized ''in house'' training courses provide incentives for technicians to broaden their academic base concurrent with their work involvement

  20. Design and preliminary validation of a mobile application-based expert system to facilitate repair of medical equipment in resource-limited health settings

    Directory of Open Access Journals (Sweden)

    Wong AL

    2018-05-01

    Full Text Available Alison L Wong,1,2 Kelly M Lacob,1 Madeline G Wilson,1 Stacie M Zwolski,1 Soumyadipta Acharya1 1Center for Bioengineering, Innovation and Design, Johns Hopkins University, Baltimore, MD, USA; 2Division of Plastic Surgery, Dalhousie University, Halifax, NS, Canada Background: One of the greatest barriers to safe surgery is the availability of functional biomedical equipment. Biomedical technicians play a major role in ensuring that equipment is functional. Following in-field observations and an online survey, a mobile application was developed to aid technicians in troubleshooting biomedical equipment. It was hypothesized that this application could be used to aid technicians in equipment repair, as modeled by repair of a pulse oximeter.Methods: To identify specific barriers to equipment repair and maintenance for biomedical technicians, an online survey was conducted to determine current practices and challenges. These findings were used to guide the development of a mobile application system that guides technicians through maintenance and repair tasks. A convenience sample of technicians in Ethiopia tested the application using a broken pulse oximeter task and following this completed usability and content validity surveys.Results: Fifty-three technicians from 13 countries responded to the initial survey. The results of the survey showed that technicians find equipment manuals most useful, but these are not easily accessible. Many do not know how to or are uncomfortable reaching out to human resources. Thirty-three technicians completed the broken pulse oximeter task using the application. All were able to appropriately identify and repair the equipment, and post-task surveys of usability and content validity demonstrated highly positive scores (Agree to Strongly Agree on both scales.Discussion: This research demonstrates the need for improved access to resources for technicians and shows that a mobile application can be used to address a gap in

  1. Establishing a clinical pharmacy technician at a United States Army military treatment facility.

    Science.gov (United States)

    Evans, Jennifer L; Gladd, Ellen M; Gonzalez, Alicia C; Tranam, Salman; Larrabee, Joni M; Lipphardt, Sarah E; Chen, Tina T; Ronn, Michael D; Spain, John

    2016-01-01

    To describe the creation of a clinical pharmacy technician position within the U.S. Army and to identify the personal skills and characteristics required to meet the demands of this role. An outpatient military treatment facility located in Maryland. The clinical pharmacy technician position was designed to support clinical pharmacy services within a patient-centered medical home. Funding and a position description were established to hire a clinical pharmacy technician. Expected duties included administrative (45%), patient education (30%), and dispensing (25%). Local policy, in accordance with federal law and U.S. Army regulations, was developed to define the expanded technician responsibility to deliver patient medication education. In the initial 3 months, the clinical pharmacy technician spent 24 hours per week on clinical activities, affording an additional 10-15 hours per week for clinical pharmacists to provide patient care. Completed consults increased from 41% to 56%, and patient-pharmacist encounters increased from 240 to 290 per month. The technician, acting as a clinical pharmacist extender, also completed an average of 90 patient encounters independently each month. As a result of these improvements, the decision was made to hire a second technician. Currently, the technicians spend 28-40 hours per week on clinical activities, offsetting an average of 26 hours per week for the clinical pharmacists. A patient-centered medical home clinical pharmacy technician can reduce the administrative workload for clinical pharmacists, improve their efficiency, and enhance the use of clinical pharmacy services. Several characteristics, particularly medication knowledge, make pharmacy technicians particularly suited for this role. The results from the implementation of a clinical pharmacy technician at this military treatment facility resulted in an Army-wide expansion of the position and suggested applicability in other practice sites, particularly in federal

  2. A Novel Simulation Technician Laboratory Design: Results of a Survey-Based Study.

    Science.gov (United States)

    Ahmed, Rami; Hughes, Patrick G; Friedl, Ed; Ortiz Figueroa, Fabiana; Cepeda Brito, Jose R; Frey, Jennifer; Birmingham, Lauren E; Atkinson, Steven Scott

    2016-03-16

    OBJECTIVE : The purpose of this study was to elicit feedback from simulation technicians prior to developing the first simulation technician-specific simulation laboratory in Akron, OH. Simulation technicians serve a vital role in simulation centers within hospitals/health centers around the world. The first simulation technician degree program in the US has been approved in Akron, OH. To satisfy the requirements of this program and to meet the needs of this special audience of learners, a customized simulation lab is essential. A web-based survey was circulated to simulation technicians prior to completion of the lab for the new program. The survey consisted of questions aimed at identifying structural and functional design elements of a novel simulation center for the training of simulation technicians. Quantitative methods were utilized to analyze data. Over 90% of technicians (n=65) think that a lab designed explicitly for the training of technicians is novel and beneficial. Approximately 75% of respondents think that the space provided appropriate audiovisual (AV) infrastructure and space to evaluate the ability of technicians to be independent. The respondents think that the lab needed more storage space, visualization space for a large number of students, and more space in the technical/repair area. CONCLUSIONS : A space designed for the training of simulation technicians was considered to be beneficial. This laboratory requires distinct space for technical repair, adequate bench space for the maintenance and repair of simulators, an appropriate AV infrastructure, and space to evaluate the ability of technicians to be independent.

  3. Technician Shawn Warren carefully smoothes out the composite skin of an instrument fairing atop the

    Science.gov (United States)

    2002-01-01

    Technician Shawn Warren carefully smoothes out the composite skin of an instrument fairing atop the upper fuselage of the Altair unmanned aerial vehicle (UAV) at General Atomics Aeronautical Systems, Inc., facility at Adelanto, Calif. General Atomics Aeronautical Systems, Inc., is developing the Altair version of its Predator B unmanned reconnaissance aircraft under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. NASA plans to use the Altair as a technology demonstrator to validate a variety of command and control technologies for UAVs, as well as demonstrate the capability to perform a variety of Earth science missions. The Altair is designed to carry an 700-lb. payload of scientific instruments and imaging equipment for as long as 32 hours at up to 52,000 feet altitude. Eleven-foot extensions have been added to each wing, giving the Altair an overall wingspan of 86 feet with an aspect ratio of 23. It is powered by a 700-hp. rear-mounted TPE-331-10 turboprop engine, driving a three-blade propeller. Altair is scheduled to begin flight tests in the fourth quarter of 2002, and be acquired by NASA following successful completion of basic airworthiness tests in early 2003 for evaluation of over-the-horizon control, detect, see and avoid and other technologies required to allow UAVs to operate safely with other aircraft in the national airspace.

  4. Technician Dave Brown installs a drilling template during construction of the all-composite left win

    Science.gov (United States)

    2002-01-01

    Technician Dave Brown installs a drilling template during construction of the all-composite left wing of NASA's Altair aircraft at General Atomics Aeronautical Systems, Inc., (GA-ASI) facility at Adelanto, Calif. General Atomics Aeronautical Systems, Inc., is developing the Altair version of its Predator B unmanned reconnaissance aircraft under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. NASA plans to use the Altair as a technology demonstrator to validate a variety of command and control technologies for UAVs, as well as demonstrate the capability to perform a variety of Earth science missions. The Altair is designed to carry an 700-lb. payload of scientific instruments and imaging equipment for as long as 32 hours at up to 52,000 feet altitude. Eleven-foot extensions have been added to each wing, giving the Altair an overall wingspan of 86 feet with an aspect ratio of 23. It is powered by a 700-hp. rear-mounted TPE-331-10 turboprop engine, driving a three-blade propeller. Altair is scheduled to begin flight tests in the fourth quarter of 2002, and be acquired by NASA following successful completion of basic airworthiness tests in early 2003 for evaluation of over-the-horizon control, detect, see and avoid and other technologies required to allow UAVs to operate safely with other aircraft in the national airspace.

  5. Justification of parameters and selection of equipment for laboratory researches of a rammer's operating element dynamics in a soil foundation of a tank for oil and oil products storage

    Science.gov (United States)

    Gruzin, A. V.; Gruzin, V. V.; Shalay, V. V.

    2017-08-01

    The development of technology for a directional soil compaction of tank foundations for oil and oil products storage is a relevant problem which solution will enable simultaneously provide required operational characteristics of a soil foundation and reduce time and material costs to prepare the foundation. The impact dynamics of rammers' operating elements on the soil foundation is planned to specify in the course of laboratory studies. A specialized technique is developed to justify the parameters and select the equipment for laboratory researches. The usage of this technique enabled us to calculate dimensions of the models, of a test bench and specifications of the recording equipment, and a lighting system. The necessary equipment for laboratory studies was selected. Preliminary laboratory tests were carried out. The estimate of accuracy for planned laboratory studies was given.

  6. Professional expectations of students of the oral health technician course

    Directory of Open Access Journals (Sweden)

    José Ferreira Lima Junior

    2012-03-01

    Full Text Available Objective: To identify the expectations of students enrolled in the oral health technician course conducted by the School of Public Health of Ceará, about their professional future. Methods:This work presents a quantitative, cross-sectional descriptive study held with students of seven classes in dental hygiene course conducted by the School of Public Health. Data collection was conducted between March and April 2011, through the application of a semistructured questionnaire, which addressed the professional profile of the participants, their expectations about the labor market and the profession. Statistical analysis was performedwith a degree of significance of 0.05. Results: 154 students were interviewed, of whom 96.1% were women, mean age of 32.9 (± 7.3 years. Most (93.8%, N = 120 graduated from high school and 71.1% (N = 108 were registered at the Regional Council of Dentistry. Regardingtheir insertion in the labor market, 42.9% believed it would be satisfactory and 58% that it would occur in public service. The biggest obstacle mentioned by the subjects about the insertion of oral health technicians in the labor market was the difficulty of hiring (45.5%. When asked to punctuate some actions that they would play as TSB, 82.2% cited clinical and collective actions. The majority (96% claimed to feel safe to act as TSB. Conclusion:The students’ expectations regarding their professional future are positive. However, it is necessary to develop further research in this area, so that the profession has a growing support within the labor market.

  7. Development of new core competencies for Taiwanese Emergency Medical Technicians.

    Science.gov (United States)

    Chang, Yu-Tung; Tsai, Kuang-Chau; Williams, Brett

    2018-01-01

    Core competencies are considered the foundation for establishing Emergency Medical Technician (EMT) and paramedic curricula, and for ensuring performance standards in the delivery of prehospital care. This study surveyed EMT instructors and medical directors to identify the most desirable core competencies for all levels of EMTs in Taiwan. A principal components analysis with Varimax rotation was conducted. An online questionnaire was distributed to obtain perspectives of EMT instructors and medical directors on the most desirable core competencies for EMTs. The target population was EMT training-course instructors and medical directors of fire departments in Taiwan. The questionnaire comprised 61 competency items, and multiple-choice and open-ended questions were used to obtain respondents' perspectives of the Taiwanese EMT training and education system. The results identified three factors at EMT-1 and EMT-2 levels and five factors at the EMT-Paramedic level. The factors for EMT-1 and EMT-2 were similar, and those for EMT-Paramedics identified further comprehensive competence perspectives. The key factors that appear to influence the development of the Taiwanese Emergency Medical Services (EMS) education system are the attitude of authorities, the licensure system, and legislation. The findings present new core competencies for the Taiwanese EMT system and provide capacity to redesign curricula and reconsider roles for EMT-1 and EMT-2 technicians. At the EMT-Paramedic level, the findings demonstrate the importance of incorporating competency standards in the current skills-based curriculum. Moreover, the core-competencies gap that exists between Taiwanese EMT-1s, EMT-2s, and EMT-Paramedics and internationally recognized core competencies needs to be addressed. By identifying the key factors that potentially impact the development of the EMS education system, such as the attitude of authorities, the licensure system, and legislation, these findings will inform

  8. The Validity of Subjects in Korean Dental Technicians' Licensing Examination

    Directory of Open Access Journals (Sweden)

    Woong-chul Kim

    2005-06-01

    Full Text Available This study prepared a basic framework for the development and improvement of Korean Dental Technicians' Licensing Examination, based on actual test questions. A peer review was conducted to ensure relevance to current practices in dental technology. For the statistical analysis, 1000 dental laboratory technicians were selected; specialists in dental laboratory technology (laboratory owners, educators, etc. were involved in creating valid and reliable questions. Results indicated that examination subjects should be divided into three categories: basic dental laboratory theory, dental laboratory specialties, and a practical examination. To ensure relevance to current practice, there should be less emphasis on basic dental laboratory theory, including health-related laws, and more emphasis on dental laboratory specialties. Introduction to dental anatomy should be separated from oral anatomy and tooth morphology; and fixed prosthodontics should be separated from crown and bridge technology and dental ceramics technology. Removable orthodontic appliance technology should be renamed 'orthodontic laboratory technology'. There should be less questions related to health related law, oral anatomy, dental hygiene, dental materials science and inlay, while the distribution ratio of questions related to tooth morphology should be maintained. There should be a decrease in the distribution ratio of questions related to crown and bridge technology, dental ceramics technology, complete dentures and removable partial dentures technology, and orthodontic laboratory technology. In the practical examination, the current multiple choice test should be replaced with tooth carving using wax or plaster. In dental laboratory specialties, subjects related to contemporary dental laboratory technology should be included in the test items.

  9. 14 CFR 65.80 - Certificated aviation maintenance technician school students.

    Science.gov (United States)

    2010-01-01

    ... students has made satisfactory progress at the school and is prepared to take the oral and practical tests... technician school students. 65.80 Section 65.80 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... § 65.80 Certificated aviation maintenance technician school students. Whenever an aviation maintenance...

  10. The law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1977-01-01

    The Law aims to define the qulifications of radiation and x-ray technicians engaging in medical treatment and to regulate so that the works are carried out properly for helping popularization and improvement of medicine and public hygiene. Persons who wish to be radiation or x-ray technicians engaging in medical treatment are required to pass the examinations for such technicians and obtain the licenes of the Minister of Health and Welfare for the former technicians and the license of a prefectural governor for the latter technicians. Mentally disordered, deaf, dumb or blind persons are excluded from licensees. Registration of such technicians, delivery of the license certificates and other related matters are provided for. The examinations are held concerning the knowledges and skills necessary for such technicians and carried out by the Minister of Health and Welfare. Persons except doctors, dentists and such technicians are prohibited to engage in the practices to apply radiation to human bodies. Restrictions on the intensity of radiation applied and the places of work are defined concerning such practices. Penal servitude of less than a year and fines less than yen 10,000 or yen 5,000 are imposed upon the violation of such prohibitions or restrictions. (Okada, K.)

  11. Advances and results of the educative project: Implementation of the career of 'Technician in Radiological protection'

    International Nuclear Information System (INIS)

    Vizuet G, J.; Suarez, G.; Sanchez C, M.

    2003-01-01

    In this work the obtained advances and achievements during the impartment of the technician career in radiological protection are presented. This is carried out in the 'Justo Sierra' Technological High School Center of San Mateo Atenco, Estado de Mexico, and has for objective the formation of professional-technicians. (Author)

  12. Examining Career Success of Minority and Women Emergency Medical Technicians (EMTs): A LEADS Project

    Science.gov (United States)

    Russ-Eft, Darlene F.; Dickison, Philip D.; Levine, Roger

    2008-01-01

    Emergency medical technicians (EMTs) are a critical segment in prehospital medical care. This study examined EMT-paramedic career success focused on minorities and women, as part of the Longitudinal Emergency Medical Technician Attributes and Demographics Study (LEADS). The LEADS data come from a representative sampling of EMTs throughout the…

  13. Task Analysis and Job Descriptions for Robotics/Automated Systems Technicians. Final Report. Volume 1.

    Science.gov (United States)

    Hull, Daniel M.; Lovett, James E.

    The Robotics/Automated Systems Technician (RAST) project developed a robotics technician model curriculum for the use of state directors of vocational education and two-year college vocational/technical educators. A baseline management plan was developed to guide the project. To provide awareness, project staff developed a dissemination plan…

  14. Management competencies required in the transition from a technician to a supervisor

    Directory of Open Access Journals (Sweden)

    Sibongile R. Mahlangu (Kubheka

    2015-05-01

    Full Text Available Orientation: Technicians are frequently promoted to supervisory positions based on their technical abilities, with scant attention focused on developing management competencies. This oversight often poses significant challenges. The effective transition from technician to supervisor is important in any organisation. Research objective: The primary objective is to identify and verify the competencies that are required for a technician and a supervisory position; the secondary objective is to identify the gap that must be filled with relevant training interventions to enable technicians to make an effective transition to a supervisory position. Motivation for this study: The identification of the management competencies required for a technician who makes a career change to a supervisor position. Research method: The sequential mixed method approach was used to enable the twophase data collection process: phase one was the quantitative phase and phase two was the qualitative phase. Main findings: The overall findings confirm that there are indeed management competencies that technicians require training and development on before being promoted to a supervisory position. Implication: Organisations need to identify the key competencies for a technician and a supervisor and implement development or training interventions that are essential to successfully transition an employee from the level of a technician to the level of a supervisor. Contribution: Organisations need to implement essential development or training interventions focused on developing management competencies and put in place support interventions such as coaching, job shadowing, mentoring and networking.

  15. Division of Scientific Equipment - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2002-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: * designs of devices and equipment for experiments in physics; their mechanical construction and assembly. In particular, these are vacuum chambers and installations for HV and UHV;* maintenance and upgrading of the existing installations and equipment in our Institute; * participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and an A0 plotter, which allow us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop offers a wide range of machining and treatment methods with satisfactory tolerances and surface quality. They include: * turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc type elements of a diameter up to 600 mm and a length not exceeding 300 mm, * milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm, * grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm, * drilling - holes of a diameter up to 50 mm, * welding - electrical and gas welding, including TIG vacuum-tight welding, * soft and hard soldering, * mechanical works including precision engineering, * plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides, * painting - paint spraying with possibility of using furnace-fired drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop is equipped with the CNC milling machine which can be used for machining of work pieces up to 500 kg. The machine

  16. Equipment support for the implementation of safeguards

    International Nuclear Information System (INIS)

    Arlt, R.; Bosler, G.; Goldfarb, M.; Schanfein, M.; Whichello, J.

    2001-01-01

    Full text: The provision of effective, reliable, and user-friendly equipment needed for the implementation of safeguards is one of the main objectives of the Division of Technical Services (SOTS) in the Department of Safeguards. As an outcome of a review by an independent external consultant firm, the instrumentation sections of the SGTS were reorganized in January 2001 into two new sections, the Section for NDA Systems and Seals (TNS) and Section for Installed Systems (TIE). Each section has 'cradle-to-grave' responsibilities for development, implementation, maintenance, and decommissioning of safeguards instruments and measurement systems. Unattended assay, monitoring and surveillance instruments are the responsibility of TIE while attended nondestructive assay (NDA) instruments and seals are handled by TNS. The principal goals of both sections are to define equipment requirements based on Departmental needs, to coordinate Support Programme tasks concerning development and implementation activities, to provide system engineering of commercial components, manage laboratory and to do field testing and prove system suitability for defined safeguards applications. In addition both sections coordinate equipment and supply needs for the Department, including acquisition, preparation, servicing, installation, commissioning, troubleshooting, maintenance and repair, ensuring their availability when needed. As required, TIE and TNS provide specialized field support to the Operations Divisions. Each section is working to standardize equipment as much as possible and reduce the number of instruments performing the same function. This reduces both inspector and technician training, required parts inventories, and overall life-cycle costs. Development based on User Needs from the Operations Divisions follows a strict quality control program that includes a thorough qualification testing procedure with the last phase being field-testing under actual facility conditions. A

  17. A technician from NASDA test the real-time radiation monitoring device on SPACEHAB in preparation fo

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  18. Job satisfaction and patient care practices of hemodialysis nurses and technicians.

    Science.gov (United States)

    Perumal, Seena; Sehgal, Ashwini R

    2003-10-01

    The quality of hemodialysis care has been the focus of intense scrutiny, yet little is known about the job satisfaction of the nurses and technicians providing this care. We identified 240 nurses and technicians from 307 randomly selected American facilities and asked them about (a) specific domains of job satisfaction, (b) overall job satisfaction, and (c) self-reported patient care practices. Fewer than half of nurses and technicians were satisfied with their pay or their opportunities for advancement. Almost all subjects were satisfied with their personal delivery of patient care, their chance to do things for others, and their job security. About three-fourths of nurses and technicians expressed overall satisfaction with their jobs. Higher job satisfaction was associated with increased attention to patient psychosocial and educational needs. We urge local and national associations of nurses and technicians to collaborate with dialysis facilities, chains, and regulatory agencies to address specific aspects of job satisfaction.

  19. Construction of a model of the process of accumulation of radionuclides of corrosion products on the equipment in nuclear power plants with boiling-water reactors

    International Nuclear Information System (INIS)

    Tevlin, S.A.

    1985-01-01

    This paper addresses the problem of corrosion of the structural materials of the reactor loop. This problem can be solved by constructing physical models of the process of accumulation of radionuclides on the equipment at nuclear power plants and by constructing the analytical apparatus for describing them. These models are presented here, and allow the analyzing of the effect of separate states and thermophysical factors, determination of the basic factors, and the ability to foresee in timely fashion the water state and structural measures required to lower the rate of growth and to decrease the amount of radionuclides deposited on the equipment in the nuclear power plant

  20. The Iowa new practice model: Advancing technician roles to increase pharmacists' time to provide patient care services.

    Science.gov (United States)

    Andreski, Michael; Myers, Megan; Gainer, Kate; Pudlo, Anthony

    Determine the effects of an 18-month pilot project using tech-check-tech in 7 community pharmacies on 1) rate of dispensing errors not identified during refill prescription final product verification; 2) pharmacist workday task composition; and 3) amount of patient care services provided and the reimbursement status of those services. Pretest-posttest quasi-experimental study where baseline and study periods were compared. Pharmacists and pharmacy technicians in 7 community pharmacies in Iowa. The outcome measures were 1) percentage of technician verified refill prescriptions where dispensing errors were not identified on final product verification; 2) percentage of time spent by pharmacists in dispensing, management, patient care, practice development, and other activities; 3) the number of pharmacist patient care services provided per pharmacist hours worked; and 4) percentage of time that technician product verification was used. There was no significant difference in overall errors (0.2729% vs. 0.5124%, P = 0.513), patient safety errors (0.0525% vs. 0.0651%, P = 0.837), or administrative errors (0.2204% vs. 0.4784%, P = 0.411). Pharmacist's time in dispensing significantly decreased (67.3% vs. 49.06%, P = 0.005), and time in direct patient care (19.96% vs. 34.72%, P = 0.003), increased significantly. Time in other activities did not significantly change. Reimbursable services per pharmacist hour (0.11 vs. 0.30, P = 0.129), did not significantly change. Non-reimbursable services increased significantly (2.77 vs. 4.80, P = 0.042). Total services significantly increased (2.88 vs. 5.16, P = 0.044). Pharmacy technician product verification of refill prescriptions preserved dispensing safety while significantly increasing the time spent in delivery of pharmacist provided patient care services. The total number of pharmacist services provided per hour also increased significantly, driven primarily by a significant increase in the number of non

  1. Use of a pharmacy technician to facilitate postfracture care provided by clinical pharmacy specialists.

    Science.gov (United States)

    Irwin, Adriane N; Heilmann, Rachel M F; Gerrity, Theresa M; Kroner, Beverly A; Olson, Kari L

    2014-12-01

    The ability of a pharmacy technician to support the patient screening and documentation-related functions of a pharmacist-driven osteoporosis management service was evaluated. A two-phase prospective study was conducted within a large integrated health system to assess a pharmacy technician's performance in supporting a multisite team of clinical pharmacy specialists providing postfracture care. In phase I of the study, a specially trained pharmacy technician provided support to pharmacists at five participating medical offices, helping to identify patients requiring pharmacist intervention and, when applicable, collecting patient-specific clinical information from the electronic health record. In phase II of the study, the amount of pharmacist time saved through the use of technician support versus usual care was evaluated. The records of 127 patient cases were reviewed by the pharmacy technician during phase I of the study, and a pharmacist agreed with the technician's determination of the need for intervention in the majority of instances (92.9%). An additional 91 patient cases were reviewed by the technician in phase II of the research. With technician support, pharmacists spent less time reviewing cases subsequently determined as not requiring intervention (mean ± S.D., 5.0 ± 3.8 minutes per case compared with 5.2 ± 4.5 minutes under the usual care model; p = 0.78). In cases requiring intervention, technician support was associated with a reduction in the average pharmacist time spent on care plan development (13.5 ± 7.1 minutes versus 18.2 ± 16.6 minutes with usual care, p = 0.34). The study results suggest that a pharmacy technician can accurately determine if a patient is a candidate for pharmacist intervention and collect clinical information to facilitate care plan development. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. Pharmacy technician self-efficacies: Insight to aid future education, staff development, and workforce planning.

    Science.gov (United States)

    Desselle, Shane P; Hoh, Ryan; Holmes, Erin R; Gill, Amanpreet; Zamora, Lemuel

    2017-07-15

    The roles of pharmacy technicians are increasingly prominent given pharmacy's transition to patient-centered activities and evolving scopes of practice in many U.S. states and throughout the world. The aims of this study were to assess U.S. pharmacy technicians' self-efficacies for and attitudes toward performing current and emerging roles in hospital and in community pharmacy and to identify factors related to pharmacy technician self-efficacies in these roles. A total of 5000 pharmacy technicians from 8 U.S. states were sent an electronic survey eliciting data on current involvement, self-efficacies, and attitudes for practicing in an expansive list of practice activities. The 8 states from which the sample was drawn were selected from a stratified randomized procedure using U.S. Census Bureau geographically defined regions. Pre-notification and response reminders were employed. Data were analyzed descriptively and with univariate, inferential tests, as appropriate, to determine associations with commitment, practice environment, experience level, and other variables. Of the 612 participants who responded, 494 were currently working as a technician and not enrolled in a PharmD program of study. Participants reported various activities in which they were highly engaged. Overall, attitudes toward performing most of the activities and self-efficacies were quite favorable, even for those activities in which technicians were currently less involved. There were some notable differences between technicians practicing in community versus hospital settings. Years of experience, profession commitment, and advanced employee ranking were associated with higher levels of self-efficacy, overall. This initial examination of pharmacy technician self-efficacies identified areas that along with other factors could help employers with further expanding technician practice activities and vocational institutions with considerations for education and development of these key members

  3. Best possible medication history for hemodialysis patients obtained by a pharmacy technician.

    Science.gov (United States)

    Leung, Marianna; Jung, Joanne; Lau, Wynnie; Kiaii, Mercedeh; Jung, Beverly

    2009-09-01

    Outpatients undergoing hemodialysis are at high risk for adverse drug events. Limited resources make it challenging for pharmacists to routinely obtain a best possible medication history (BPMH). The primary objective was to determine whether, for patients undergoing hemodialysis, a pharmacy technician has the skills to obtain a BPMH that would allow a pharmacist to identify drug-related problems. The secondary objectives were to determine the number and types of medication discrepancies and drug-related problems identified and the time required by the technician to complete the BPMH. All patients treated in the hemodialysis unit during the study period were included, except for those who required an interpreter or were unable to participate in an in-person interview. A single technician was taught how to interview patients according to a structured format. For each patient, the technician's BMPH was verified by a pharmacist. The agreement rate between technician and pharmacists was determined, along with the number and types of discrepancies and drug-related problems identified. The technician interviewed 99 patients. Of the 1334 medication orders reviewed, the technician and pharmacists agreed on all but 15 (agreement rate 98.9%). A total of 358 medication discrepancies were noted for 93 patients (3.8 discrepancies per patient). Of these, 210 (59%) were undocumented intentional discrepancies, and 148 (41%) were unintentional discrepancies (most commonly errors of commission). Of the 135 drug-related problems identified, the majority involved dosing problems or nonadherence. The technician required an average of 17 min for each interview. An adequately trained technician was capable of interviewing patients to create a BPMH. A variety of medication discrepancies and drug-related problems were identified. Generation of a BPMH by a technician is a useful approach allowing pharmacists to identify drug-related problems.

  4. Effect of specific resistance training on forearm pain and work disability in industrial technicians: cluster randomised controlled trial

    DEFF Research Database (Denmark)

    Andersen, Lars Louis; Jakobsen, Markus D; Pedersen, Mogens Theisen

    2012-01-01

    To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians.......To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians....

  5. Communication received from the permanent mission of Austria regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1996-01-01

    The Director General received a note verbale of 13 June 1996 from Permanent Mission of Austria regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material. In the light of the request expressed at the end of the note verbale, the text of the note verbale is being circulated

  6. Communication received from the Permanent Mission of Sweden regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1996-01-01

    The document reproduces the text of a note verbale dated 28 June 1996 received by the Director General of IAEA from the Permanent Mission of Sweden through which the Government of Sweden provides, on a voluntary basis, certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material, in order to assist the Agency in the discharge of its safeguards responsibilities

  7. Communication received from the permanent mission of Finland regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1996-01-01

    The Director General received a note verbale of 8 February 1996 from Permanent Mission of Finland regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material. In the light of the request expressed at the and of the note verbale, the text of the note verbale is being circulated

  8. Development of new core competencies for Taiwanese Emergency Medical Technicians

    Directory of Open Access Journals (Sweden)

    Chang YT

    2018-03-01

    Full Text Available Yu-Tung Chang,1,2 Kuang-Chau Tsai,2 Brett Williams1,3 1Department of Community Emergency Health and Paramedic Practice, Faculty of Medicine, Nursing and Health Sciences, Monash University, Frankston, VIC, Australia; 2Department of Emergency Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan; 3Division of Paramedicine, University of Tasmania, Hobart, TAS, Australia Objectives: Core competencies are considered the foundation for establishing Emergency Medical Technician (EMT and paramedic curricula, and for ensuring performance standards in the delivery of prehospital care. This study surveyed EMT instructors and medical directors to identify the most desirable core competencies for all levels of EMTs in Taiwan. Methods: A principal components analysis with Varimax rotation was conducted. An online questionnaire was distributed to obtain perspectives of EMT instructors and medical directors on the most desirable core competencies for EMTs. The target population was EMT training-course instructors and medical directors of fire departments in Taiwan. The questionnaire comprised 61 competency items, and multiple-choice and open-ended questions were used to obtain respondents’ perspectives of the Taiwanese EMT training and education system. Results: The results identified three factors at EMT-1 and EMT-2 levels and five factors at the EMT-Paramedic level. The factors for EMT-1 and EMT-2 were similar, and those for EMT-Paramedics identified further comprehensive competence perspectives. The key factors that appear to influence the development of the Taiwanese Emergency Medical Services (EMS education system are the attitude of authorities, the licensure system, and legislation. Conclusion: The findings present new core competencies for the Taiwanese EMT system and provide capacity to redesign curricula and reconsider roles for EMT-1 and EMT-2 technicians. At the EMT-Paramedic level, the findings demonstrate the importance of

  9. Riser equipment decontamination engineering task plan; TOPICAL

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    On October 15, 1998, two Characterization Project Operations (CPO) employees were found to have contaminated clothing. An operator had 300,000-dpm/100cm2 beta/gamma, no alpha, contamination on his coat sleeve and a Radiation Control Technician (RCT) had 10,000 dpm/100cm2 beta/gamma, no alpha, on his shirt sleeve. The CPO swing shift crew was working in TX tank farm, performing sampling activities at 241-TX-113. TX tank farm is a ''clean farm'' and does not require anti-contamination clothing for entry. The CPO personnel were dressed in normal work clothes. An operator and an RCT were performing a pre-job survey that involved removing bagging around the riser equipment. When the RCT saw that the contamination readings from smear samples of the riser equipment were greater than expected, the job was suspended. Crew members were then directed to areas of lower background radiation for personnel surveys. During personnel surveys, reportable contamination was found on the coat sleeve of the operator who had been involved in the pre-job survey and on the shirt sleeve of the RCT who had been involved in the pre-job survey. No other personnel were found to be contaminated. Because of this off normal event Characterization Engineering was given the following corrective action: Examine the process methodology used for core sampling operations to determine practicality and potential long-term advantages of reducing personnel contact with contaminated equipment. This Engineering Task Plan ensures that LMHC 1998a, Corrective Action No.7 is completely addressed by Characterization Engineering. The deliverable is an Engineering Study that evaluates decontamination of riser equipment components and considers additional engineered features to reduce potential exposure to workers operating the riser equipment. This engineering study shall also address any released design features that have failed to be implemented

  10. Riser equipment decontamination engineering task plan

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    On October 15, 1998, two Characterization Project Operations (CPO) employees were found to have contaminated clothing. An operator had 300,000-dpm/100cm2 beta/gamma, no alpha, contamination on his coat sleeve and a Radiation Control Technician (RCT) had 10,000 dpm/100cm2 beta/gamma, no alpha, on his shirt sleeve. The CPO swing shift crew was working in TX tank farm, performing sampling activities at 241-TX-113. TX tank farm is a ''clean farm'' and does not require anti-contamination clothing for entry. The CPO personnel were dressed in normal work clothes. An operator and an RCT were performing a pre-job survey that involved removing bagging around the riser equipment. When the RCT saw that the contamination readings from smear samples of the riser equipment were greater than expected, the job was suspended. Crew members were then directed to areas of lower background radiation for personnel surveys. During personnel surveys, reportable contamination was found on the coat sleeve of the operator who had been involved in the pre-job survey and on the shirt sleeve of the RCT who had been involved in the pre-job survey. No other personnel were found to be contaminated. Because of this off normal event Characterization Engineering was given the following corrective action: Examine the process methodology used for core sampling operations to determine practicality and potential long-term advantages of reducing personnel contact with contaminated equipment. This Engineering Task Plan ensures that LMHC 1998a, Corrective Action No.7 is completely addressed by Characterization Engineering. The deliverable is an Engineering Study that evaluates decontamination of riser equipment components and considers additional engineered features to reduce potential exposure to workers operating the riser equipment. This engineering study shall also address any released design features that have failed to be implemented

  11. 40 CFR 745.92 - Fees for the accreditation of renovation and dust sampling technician training and the...

    Science.gov (United States)

    2010-07-01

    ... renovation and dust sampling technician training and the certification of renovation firms. 745.92 Section... Renovation § 745.92 Fees for the accreditation of renovation and dust sampling technician training and the... the following disciplines: Renovator, dust sampling technician. (ii) Exemption. No fee shall be...

  12. 20 CFR 1002.306 - Is a National Guard civilian technician considered a State or Federal employee for purposes of...

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Is a National Guard civilian technician... a National Guard civilian technician considered a State or Federal employee for purposes of USERRA? A National Guard civilian technician is considered a State employee for USERRA purposes, although he...

  13. Defining the Role of the Pharmacy Technician and Identifying Their Future Role in Medicines Optimisation.

    Science.gov (United States)

    Boughen, Melanie; Sutton, Jane; Fenn, Tess; Wright, David

    2017-07-15

    Traditionally, pharmacy technicians have worked alongside pharmacists in community and hospital pharmacy. Changes within pharmacy provide opportunity for role expansion and with no apparent career pathway, there is a need to define the current pharmacy technician role and role in medicines optimisation. To capture the current roles of pharmacy technicians and identify how their future role will contribute to medicines optimisation. Following ethical approval and piloting, an online survey to ascertain pharmacy technicians' views about their roles was undertaken. Recruitment took place in collaboration with the Association of Pharmacy Technicians UK. Data were exported to SPSS, data screened and descriptive statistics produced. Free text responses were analysed and tasks collated into categories reflecting the type of work involved in each task. Responses received were 393 (28%, n = 1380). Results were organised into five groups: i.e., hospital, community, primary care, General Practitioner (GP) practice and other (which included HM Prison Service). Thirty tasks were reported as commonly undertaken in three or more settings and 206 (84.7%, n = 243) pharmacy technicians reported they would like to expand their role. Tasks core to hospital and community pharmacy should be considered for inclusion to initial education standards to reflect current practice. Post qualification, pharmacy technicians indicate a significant desire to expand clinically and managerially allowing pharmacists more time in patient-facing/clinical roles.

  14. Description and comparison of pharmacy technician training programs in the United States.

    Science.gov (United States)

    Anderson, Douglas C; Draime, Juanita A; Anderson, Timothy S

    2016-01-01

    To describe pharmacy technician training programs in the United States and to compare pharmacy technician program characteristics between programs with and without a pharmacist on faculty and between programs with different accreditation status. Descriptive, cross-sectional study. Not applicable. United States pharmacy technician programs. Not applicable. Student class size, faculty credentials, coursework components, program length, tuition rates, and admission criteria. Currently, there are more than 698 pharmacy technician programs across 1114 campuses, with complete data available for 216 programs. Programs varied widely in terms of class sizes, faculty credentials, and admission criteria. Programs with pharmacists on faculty were significantly less expensive than were those without pharmacists (P = 0.009). Accreditation had no impact on tuition prices. This is the first study of its kind to describe and characterize pharmacy technician training programs. There is relatively little control of technician training by the profession of pharmacy. The quality of these programs in terms of student outcomes is unknown, and it should be explored. Rigorous debate and discussion is needed regarding the future of pharmacy technician roles and the training required for those roles. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  15. Guidebook on the education and training of technicians for nuclear power

    International Nuclear Information System (INIS)

    1989-01-01

    The IAEA Guidebook on the Education and Training of Technicians for Nuclear Power aims to assist Member States, especially the developing countries which are in the process of implementing, or intending to implement, a nuclear power programme, to understand and meet their requirements for qualified technicians in the most effective and efficient manner. It specifically seeks to assist policy makers and planners, as well as those designing and implementing education and training programmes. In this Guidebook, technician level occupations include those filled by technicians and higher level technicians (techniciens superieurs or technologists) and also by non-graduate engineers. The Guidebook complements the IAEA Guidebook on Manpower Development for Nuclear Power, as well as the IAEA Guidebook on the Qualification of Nuclear Power Plant Operations Personnel. The key objectives of this Guidebook are to describe: (1) the level and content of conventional education and training which a technician must have before nuclear oriented education and training can begin; (2) the level and content of nuclear oriented education and training; (3) measures to bridge the gap between the education and training acquired by technicians in the national technical schools (i.e. the level attained before upgrading) and the level of education and training qualifications needed for technicians to work in the nuclear power programme (i.e. the level attained after completion of nuclear oriented education and training). Valuable information on the national experiences of IAEA Member States in the education and training of technicians for nuclear power, as well as examples of such education and training from various Member States, are included in IAEA-TECDOC-526, which should be read in conjunction with the present text. 3 refs, 13 figs, 3 tabs

  16. AeroVironment technician checks a Helios solar cell panel

    Science.gov (United States)

    2000-01-01

    A technician at AeroVironment's Design Development Center in Simi Valley, California, checks a panel of silicon solar cells for conductivity and voltage. The bi-facial cells, fabricated by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the Helios Prototype solar-powered aircraft to provide power to its 14 electric motors and operating systems. Developed by AeroVironment under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project, the Helios Prototype is the forerunner of a planned fleet of slow-flying, long duration, high-altitude aircraft which can perform atmospheric science missions and serve as telecommunications relay platforms in the stratosphere. Target goals set by NASA for the giant 246-foot span flying wing include reaching and sustaining subsonic horizontal flight at 100,000 feet altitude in 2001, and sustained continuous flight for at least four days and nights above 50,000 feet altitude with the aid of a regenerative fuel cell-based energy storage system now under development in 2003.

  17. Management perceptions of the Health Physics Technician job

    International Nuclear Information System (INIS)

    Mazour, T.J.; Marotta, F.J.

    1985-12-01

    In 1984, an industry-wide job analysis of nuclear power reactor Health Physics Technicians (HPTs) was completed. These results provided the basis for job descriptions, industry-wide task listings and recommendations for task selections for further analysis and formal training. A total of 389 tasks were identified and reviewed by 850 HPTs representing 39 plants and 6 vendor companies. Constructive criticism of the HPT job analysis focused on the fact that HPT supervisors and managers were not included in the survey. Concerns were addressed that these supervisors/managers might have a divergent perception of the HPT job that could lead to different conclusions than those that were originally drawn. The only way to confirm (or deny) this hypothesis was to verify the results of the job analysis of HPTs by also surveying radiation protection management personnel. A total of 19 HPT supervisors/managers completed the same survey that had been used for HPT job incumbents. They were asked to rate each task on the basis of their job incumbents' performance of the task. Of the 1161 ratings (389 tasks each with a rating for frequency, difficulty, and importance), only 37 of the ratings differed between the HPTs and the HPT supervisors/managers (at the 99% confidence level)

  18. Barriers in detecting elder abuse among emergency medical technicians.

    Science.gov (United States)

    Reingle Gonzalez, Jennifer M; Cannell, M Brad; Jetelina, Katelyn K; Radpour, Sepeadeh

    2016-09-02

    Elder abuse and neglect are highly under-reported in the United States. This may be partially attributed to low incidence of reporting among emergency medical technicians' (EMTs), despite state-mandated reporting of suspected elder abuse. Innovative solutions are needed to address under-reporting. The objective was to describe EMTs' experience detecting and reporting elder abuse. Qualitative data were collected from 11 EMTs and 12 Adult Protective Services (APS) caseworkers that participated in one of five semi-structured focus groups. Focus group data were iteratively coded by two coders. Findings suggest a number of barriers prevent EMTs from reporting elder abuse to APS. Participants suggested that limited training on elder abuse detection or reporting has been provided to them. EMTs suggested that training, creation of an automated reporting system or brief screening tool could be used to enhance EMT's ability to detect and communicate suspected cases of elder abuse to APS. Results from the present study suggest that EMTs may be uniquely situated to serve as elder abuse and neglect surveillance personnel. EMTs are eager to work with APS to address the under-reporting of elder abuse and neglect, but training is minimal and current reporting procedures are time-prohibitive given their primary role as emergency healthcare providers. Future studies should seek to translate these findings into practice by identifying specific indicators predictive of elder abuse and neglect for inclusion on an automated reporting instrument for EMTs.

  19. OCCUPATIONAL CONTACT DERMATITIS AMONGST DENTISTS AND DENTAL TECHNICIANS.

    Science.gov (United States)

    Lugović-Mihić, Liborija; Ferček, Iva; Duvančić, Tomislav; Bulat, Vedrana; Ježovita, Josip; Novak-Bilić, Gaby; Šitum, Mirna

    2016-06-01

    Since the working medical personnel including dentists and dental technicians mainly use their hands, it is understandable that the most common occupational disease amongst medical personnel is contact dermatitis (CD) (80%-90% of cases). Development of occupational CD is caused by contact of the skin with various substances in occupational environment. Occupational etiologic factors for dental personnel are foremost reactions to gloves containing latex, followed by various dental materials (e.g., metals, acrylates), detergents, lubricants, solvents, chemicals, etc. Since occupational CD is relatively common in dental personnel, its timely recognition, treatment and taking preventive measures is needed. Achieving skin protection at exposed workplaces is of special importance, as well as implementing necessary measures consequently and sufficiently, which is sometimes difficult to achieve. Various studies have shown the benefit of applying preventive measures, such as numerous protocols for reducing and managing latex sensitivity and other forms of CD in dentistry. Active involvement of physicians within the health care system, primarily dermatologists, occupational medicine specialists and general medicine doctors is needed for establishing an accurate medical diagnosis and confirmation of occupational skin disease.

  20. Downtime after Critical Incidents in Emergency Medical Technicians/Paramedics

    Directory of Open Access Journals (Sweden)

    Janice Halpern

    2014-01-01

    Full Text Available Effective workplace-based interventions after critical incidents (CIs are needed for emergency medical technicians (EMT/paramedics. The evidence for a period out of service post-CI (downtime is sparse; however it may prevent posttraumatic stress disorder (PTSD and burnout symptoms. We examined the hypothesis that downtime post-CI is associated with fewer symptoms of four long-term emotional sequelae in EMT/paramedics: depression, PTSD, burnout, and stress-related emotional symptoms (accepted cut-offs defined high scores. Two hundred and one paramedics completed questionnaires concerning an index CI including downtime experience, acute distress, and current emotional symptoms. Nearly 75% received downtime; 59% found it helpful; 84% spent it with peers. Downtime was associated only with lower depression symptoms, not with other outcomes. The optimal period for downtime was between 1 day being less effective. Planned testing of mediation of the association between downtime and depression by either calming acute post-CI distress or feeling helped by others was not performed because post-CI distress was not associated with downtime and perceived helpfulness was not associated with depression. These results suggest that outcomes of CIs follow different pathways and may require different interventions. A brief downtime is a relatively simple and effective strategy in preventing later depression symptoms.

  1. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  2. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  3. Nuclear Technology. Course 32: Nondestructive Examination (NDE) Techniques II. Module 32-4, Operation of Magnetic Particle Test Equipment.

    Science.gov (United States)

    Groseclose, Richard

    This fourth in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II describes the specific technique variables and options which are available to the test technician, provides instructions for selecting and operating the appropriate test equipment, describes physical criteria for detectable discontinuities,…

  4. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  5. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  6. Staphylococcus aureus with Panton-Valentine toxin skin infection in a medical laboratory technician.

    Science.gov (United States)

    Pougnet, Richard; Pougnet, Laurence

    2016-12-01

    This report exposes the case of a Staphylococcus aureus infection occurring in a microbiology laboratory technician. He was a 52 year-old man without medical history. He presented an abscess on the anterior aspect of the left forearm. Analysis showed that it was a Staphylococcus aureus secreting the Panton-Valentine toxin. The study of the workplace found the frequency of exposure. The study of workstation showed the link between the technician position and the infection. Indeed, this man touched an area where the biocleaning was hard to do. This is the first case of infection with PVL described for a laboratory technician.

  7. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    International Nuclear Information System (INIS)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M.

    1989-01-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population

  8. Respiratory Systems of Dental Technicians Negatively Affected during 5 Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Nurgül Bozkurt

    2016-08-01

    Full Text Available Background: Dental laboratory technician is one of the professions in which dust exposure is frequently experienced and therefore the health of workers has to be monitored. Aims: In this study, changes in the pulmonary functions and of pneumoconiosis frequencies among dental technicians after five years were investigated by comparing the results of two screenings carried out in 2008 and 2013. Study Design: Cohort study. Methods: In 2008 and 2013, Provincial Health Directorate carried out two different health screenings covering all of the dental technicians working in dental laboratories in Denizli. In both screenings, a questionnaire was applied, with which socio-demographic and workplace properties of the technicians were obtained. In addition, Pulmonary function tests (PFT and standard chest X-rays of the technicians were performed. The results of these two screenings were evaluated by a chest specialist, and physical examinations were performed as necessary. In 2013, technicians who had pathologies underwent computerized tomography (HRCT. In this study, the study group was composed of dental laboratory technicians that participated in both screenings (2008 and 2013 and the data obtained from the screenings were compared. The gathered data were analyzed using paired student-t and X2 tests. Results: A total of 125 dental laboratory technicians participated in the two screenings. Overall, 92% of the technicians were male and the mean age of the participants was 35. Technicians were working for 9 hours a day, 6 days a week. Total exposure time was calculated to be around 41 thousand hours. Approximately 60% of workers were smokers. When the results of PFT were analyzed, 73% of the first evaluations were found to be normal; however, this ratio decreased to 51% in the second analysis five years later. In the second PFT measurement, compared to the first, there was a 23% decrease in the forced vital capacity (FVC value, and a 15.7% decrease in

  9. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M. (Universite du Quebec a Montreal (Canada))

    1989-10-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population.

  10. Mission Specialist Pedro Duque undergoes equipment check prior to launch

    Science.gov (United States)

    1998-01-01

    In the Operations and Checkout Building, STS-95 Mission Specialist Pedro Duque of Spain, with the European Space Agency, gets help with his suit from suit technician Tommy McDonald. The STS-95 crew were conducting flight crew equipment fit checks prior to launch on Oct. 29. STS-95 is expected to launch at 2 p.m. EST on Oct. 29, last 8 days, 21 hours and 49 minutes, and land at 11:49 a.m. EST on Nov. 7.

  11. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  12. Making petroleum equipment safe, a priority

    International Nuclear Information System (INIS)

    1999-01-01

    Changes to the 'Act respecting the use of petroleum products' have been announced effective May 1, 1999. The changes have been made to reduce problems which can be attributed to petroleum product leaks. The new regulations will make owners and users of petroleum equipment, including underground and above-ground storage equipment and commercial storage tanks, more accountable for the use of their own equipment. The emphasis in the new regulations is based upon the storage capacity of petroleum equipment and the risks associated with this equipment, rather than the on the activities of the owners concerned. Accordingly, the new regulations call for stricter requirements for high-risk equipment, a private equipment inspection plan, a two-year operating permit, replacing the current permits and certificates, a tariff structure based on the risks associated with the equipment, and deregulation of commercial activities involving petroleum products that require no equipment. Additionally, the amendments to the Act transfer responsibility for administration to the Regie du batiment and to the Ministere des Transports. Details of each of these changes are explained

  13. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  14. International Economic Association on organization of co-operative production and development of equipment and providing technical assistance in construction of nuclear power plants - ''INTERATOMENERGO''

    International Nuclear Information System (INIS)

    Mal'tsev, N.D.

    1979-01-01

    History is stated of foundation of the International Economic Association ''Interatomenergo''. Structure is given of the Association and the list of main problems to be solved by it. Project is given of the programm of co-operation in the field of scientific and technical works as well as of design and projecting works in creation of new types of equipment for nuclear power plants, in particular, creation of serial power units with improved WWER-1000 reactor. Directions are stated of activity of the Association in the field of providing assistance in construction and exploitation of nuclear power plants as well as in training of operational personnel [ru

  15. Management of radiodiagnostic equipment: Implementation of self-maintenance project of the conventional x-ray equipment of Hospital Universitario Clementino Fraga Filho - HUCFF-UFRJ

    International Nuclear Information System (INIS)

    Couto, N.F. do; Azevedo, A.C.P.; Koch, H.A.

    2001-01-01

    The project aims the implantation of a management program, for the maintenance of the conventional X-ray equipment at HUCFF. It has been implemented through the training of the electronic technicians who work at the Hospital. Essential courses were organized such as: Basics of Radioprotection, Radiographs Techniques, and Maintenance of equipment of X-Rays. Equipment: a library with the schemes of the equipment is being assembled in collaboration with UNICAMP. In order to manage the process, a software was created using the tools of the total quality for control of the maintenance. Preliminary tests: the equipment and their working conditions were evaluated, as well as the level of the employees' satisfaction with their use. The creation of a new routine for maintenance seeks to assist the demands of the new legislation in Brazil 5, and also reduce the costs to improve the quality of the images in the Radiodiagnostic Service. (author)

  16. Time to pregnancy among Danish laboratory technicians who were a part of the National Birth Cohort

    DEFF Research Database (Denmark)

    Zhu, Jin Liang; Knudsen, Lisbeth E; Andersen, Anne-Marie Nybo

    2005-01-01

    in 1997-2003. Altogether 6250 female teachers formed the reference group. A discrete-time survival analysis with a complementary log-log link was applied to estimate the fecundability ratio between the exposed and unexposed women, with adjustment for maternal age, gravidity, smoking, prepregnancy body......OBJECTIVES: The Danish National Birth Cohort was used to examine whether laboratory work was associated with reduced fecundity. METHODS: Self-reported data on laboratory work and waiting time to pregnancy (0-2, 3-5, 6-12 and > 12 months) were used for 829 female laboratory technicians interviewed...... mass index, and paternal job. RESULTS: No difference in time to pregnancy was found between the laboratory technicians and teachers or between the laboratory technicians with different exposures. The adjusted fecundability ratio for the laboratory technicians was 0.94 [95% confidence interval (95% CI...

  17. Multidisciplinary training program to create new breed of radiation monitor: the health and safety technician

    International Nuclear Information System (INIS)

    Vance, W.F.

    1979-01-01

    A multidiscipline training program established to create a new monitor, theHealth and Safety Technician, is described. The training program includes instruction in fire safety, explosives safety, industrial hygiene, industrial safety, health physics, and general safety practices

  18. [Competencies in the education of nursing technicians to implement the nursing care systematization].

    Science.gov (United States)

    da Cruz, Andrea de Mello Pereira; Almeida, Miriam de Abreu

    2010-12-01

    This is a qualitative, exploratory and descriptive study whose general objective was to learn, considering the perspective of the nursing technician who works in school hospitals, the competencies developed during their educational process to implement the Nursing Care Systematization (NCS). Data collection and analysis were carried out through a focal group, with content analysis and nursing technicians. Two thematic categories emerged: The participation of the nursing technician in the NCS and The competencies in the education of the nursing technician. Each one received two subcategories: Conception of the NCS and (De)valuation of the NCS, Technical-scientific competency and Competency in the interpersonal relationship, respectively. It was observed that the NCS must be shared, discussed and made public among nursing professionals, so that they may acknowledge themselves as the leading actors of their methodology and be aware that their practices determine the results.

  19. Integrated Technical Information for the Air Logistics Center: Enhancing Maintenance Technician Task Performance

    National Research Council Canada - National Science Library

    Mitta, Deborah

    1998-01-01

    This technical paper documents the final results of an analysis of the task environment under which depot maintenance technicians perform their jobs--specifically, programmed depot maintenance (PDM) for F-15 aircraft...

  20. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  1. Measuring teamwork and conflict among emergency medical technician personnel.

    Science.gov (United States)

    Patterson, P Daniel; Weaver, Matthew D; Weaver, Sallie J; Rosen, Michael A; Todorova, Gergana; Weingart, Laurie R; Krackhardt, David; Lave, Judith R; Arnold, Robert M; Yealy, Donald M; Salas, Eduardo

    2012-01-01

    We sought to develop a reliable and valid tool for measuring teamwork among emergency medical technician (EMT) partnerships. We adapted existing scales and developed new items to measure components of teamwork. After recruiting a convenience sample of 39 agencies, we tested a 122-item draft survey tool (EMT-TEAMWORK). We performed a series of exploratory factor analyses (EFAs) and confirmatory factor analysis (CFA) to test reliability and construct validity, describing variation in domain and global scores using descriptive statistics. We received 687 completed surveys. The EFAs identified a nine-factor solution. We labeled these factors 1) Team Orientation, 2) Team Structure & Leadership, 3) Partner Communication, Team Support, & Monitoring, 4) Partner Trust and Shared Mental Models, 5) Partner Adaptability & Back-Up Behavior, 6) Process Conflict, 7) Strong Task Conflict, 8) Mild Task Conflict, and 9) Interpersonal Conflict. We tested a short-form (30-item SF) and long-form (45-item LF) version. The CFAs determined that both the SF and the LF possess positive psychometric properties of reliability and construct validity. The EMT-TEAMWORK-SF has positive internal consistency properties, with a mean Cronbach's alpha coefficient ≥0.70 across all nine factors (mean = 0.84; minimum = 0.78, maximum = 0.94). The mean Cronbach's alpha coefficient for the EMT-TEAMWORK-LF was 0.87 (minimum = 0.79, maximum = 0.94). There was wide variation in weighted scores across all nine factors and the global score for the SF and LF. Mean scores were lowest for the Team Orientation factor (48.1, standard deviation [SD] 21.5, SF; 49.3, SD 19.8, LF) and highest (more positive) for the Interpersonal Conflict factor (87.7, SD 18.1, for both SF and LF). We developed a reliable and valid survey to evaluate teamwork between EMT partners.

  2. Measuring teamwork and conflict among Emergency Medical Technician personnel

    Science.gov (United States)

    Patterson, P. Daniel; Weaver, Matthew D.; Weaver, Sallie J.; Rosen, Michael A.; Todorova, Gergana; Weingart, Laurie R.; Krackhardt, David; Lave, Judith R.; Arnold, Robert M.; Yealy, Donald M.; Salas, Eduardo

    2011-01-01

    Objective We sought to develop a reliable and valid tool for measuring teamwork among Emergency Medical Technician (EMT) partnerships. Methods We adapted existing scales and developed new items to measure components of teamwork. After recruiting a convenience sample of 39 agencies, we tested a 122-item draft survey tool. We performed a series of Exploratory Factor Analyses (EFA) and Confirmatory Factor Analysis (CFA) to test reliability and construct validity, describing variation in domain and global scores using descriptive statistics. Results We received 687 completed surveys. The EFA analyses identified a 9-factor solution. We labeled these factors [1] Team Orientation, [2] Team Structure & Leadership, [3] Partner Communication, Team Support, & Monitoring, [4] Partner Trust and Shared Mental Models, [5] Partner Adaptability & Back-Up Behavior, [6] Process Conflict, [7] Strong Task Conflict, [8] Mild Task Conflict, and [9] Interpersonal Conflict. We tested a short form (30-item SF) and long form (45-item LF) version. The CFA analyses determined that both the SF and LF versions possess positive psychometric properties of reliability and construct validity. The EMT-TEAMWORK-SF has positive internal consistency properties with a mean Cronbach’s alpha coefficient ≥0.70 across all 9-factors (mean=0.84; min=0.78, max=0.94). The mean Cronbach’s alpha coefficient for the EMT-TEAMWORK-LF version was 0.87 (min=0.79, max=0.94). There was wide variation in weighted scores across all 9 factors and the global score for the SF and LF versions. Mean scores were lowest for the Team Orientation factor (48.1, SD 21.5 SF; 49.3 SD 19.8 LF) and highest (more positive) for the Interpersonal Conflict factor (87.7 SD 18.1 for both SF and LF). Conclusions We developed a reliable and valid survey to evaluate teamwork between EMT partners. PMID:22128909

  3. Utilizing QFD model to determine quality characteristics of the products and priority needs of customers in the medical industry products (Case Study: Plasma seat product in mashhad`s Sahateb medical equipment company

    Directory of Open Access Journals (Sweden)

    Zeinab Armoun

    2012-10-01

    Full Text Available Quality Function Deployment (QFD as one of the quality engineering methods; originates from market study and product or service customers identification, where by determining their needs; tries to involve them in all stages of product or service development. This study uses QFD method to apply customers’ criteria in production of Coach Plasma in Mashhad`s Sahateb Company. Coach Plasma is used for healthy bloodletting. The proposed study of this paper designed and distributed a questionnaire, which includes identification & determination of customers’ needs and investigation of their satisfaction of manufactured products, while looking for technical and engineering characteristics related to their needs. The Coach Plasma costumers are categorized into two groups of local and external customers. Data collection was done based on available documents, experts opinions, structured interview with managers and questionnaire. Customers’ needs were studied in QFD teams. Collecting essential information such as needs importance degree and competitive benchmarking of customer`s needs, the weight of each need has been evaluated. In this research, House of Quality was used from first matrix of QFD leading to estimation of engineering & technical characteristics in order to enter to the quality deployment matrix. Take a look at obtained results, we could mention the role of each of these external factors in satisfaction of Sahateb Company customers and technical characteristics of the company in providing these factors and the prioritization of the customer's needs.

  4. A method for the efficient and effective evaluation of contract health physics technicians

    International Nuclear Information System (INIS)

    Burkdoll, S.C.; Conley, T.A.

    1992-01-01

    This paper reports that Wolf Creek has developed a method for efficiently training contract health physics technicians. The time allotted for training contractors prior to a refueling and maintenance outage is normally limited to a few days. Therefore, it was necessary to develop a systematic method to evaluate prior experience as well as practical skills and knowledge. In addition, instruction in the particular methodologies used at Wolf Creek hadto be included with methods for evaluating technician comprehension

  5. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  6. A longitudinal study on lung disease in dental technicians: What has changed after seven years?

    Directory of Open Access Journals (Sweden)

    Derya Özdemir Dogan

    2013-10-01

    Full Text Available Objectives: The aim of this 7-year follow-up study was to determine respiratory changes in dental technicians. Material and Methods: In our region, in the year 2005, 36 dental technicians were evaluated with a cross-sectional study on respiratory occupational diseases, and in 2012 we evaluated them again. Inclusion of information on respiratory symptoms and demographic features questionnaires was applied. Pulmonary function tests (PFT were performed. Chest X-rays (CXR were evaluated according to the ILO-2000 classification. For the comparisons of the technicians' findings in 2005 and 2012, data analyses were performed with the Wilcoxon test in addition to descriptive statistical procedures. Results: In 2012, 19 out of the 36 technicians continued to work in the same place, so we were able to evaluate their findings. The prevalence of respiratory symptoms in dental technician was as follows: dyspnea 7 (37%, cough 6 (32%, and phlegm 5 (26%. According to ILO classifications in 2005, among the 36 technicians, 5 (13.8% had pneumoconiosis. At the end of 7 years, there were 9 pneumoconiosis cases among the 19 remaining technicians (47%. Thus, there was a statistically significant progression on the profusion of the radiologic findings (p < 0.005. Also there was a significant worsening on spirometric findings (p < 0.05. Conclusion: In dental technicians, a determination of both radiologic and functional progressions at the end of 7 years demonstrate that the primary and secondary preventive measures are necessary for these workplaces. Workplaces must be regularly controlled for worker health and hygiene.

  7. 2011 Mississippi Curriculum Framework: Postsecondary Agricultural Technician Technology. (Program CIP: 01.0201 - Agricultural Mechanics and Equipment/Machine Technology)

    Science.gov (United States)

    Massey, Jeremy; Louwerens, Shane; Galey, Joe

    2011-01-01

    As the world economy continues to evolve, businesses and industries must adopt new practices and processes in order to survive. Quality and cost control, work teams and participatory management, and an infusion of technology are transforming the way people work and do business. Employees are now expected to read, write, and communicate…

  8. Radiation protection and the safe use of X-ray equipment: Laws, regulations and responsibilities

    Directory of Open Access Journals (Sweden)

    Charles Petrus Herbst

    2012-06-01

    Full Text Available Lately, South Africa’s regulatory framework for electromagnetic medical devices has come under considerable pressure. In this article the legislative framework and regulatory infrastructure are scrutinized, by looking at how the legislature has given form to protective measures against ionizing radiation. Although the Hazardous Substances Act provides for effective protection against radiation, poor administration led to insufficient staffing levels, uncertainty about Regulations and licensing conditions and therefore undermines a sound radiation protection infrastructure. The legal basis of enforcing licensing conditions through a website without proper consultation with interested and affected parties is questionable and ineffective in controlling radiation levels. Effective and legal radiation control is possible by activating the National Advisory Committee on Electronic Products provided for in Regulation R326 published in 1979, but never implemented. The possible impact of annual quality assurance tests currently enforced through licensing conditions on the radiation dose of the population is not cost effective as new training and accreditation structures had to be created. The fact that generally more than 80% of overexposures are caused by human error is a clear indication that training of the daily users of X-ray equipment should be emphasized and not the training and accreditation of the technicians responsible for a single quality assurance test per year. Constructive engagement with the professional bodies involved in the medical use of X-rays through a National Advisory Committee on Electronic Products may be a cost effective solution for lowering radiation dose to the population.

  9. Defining the Role of the Pharmacy Technician and Identifying Their Future Role in Medicines Optimisation

    Science.gov (United States)

    Boughen, Melanie; Sutton, Jane; Fenn, Tess

    2017-01-01

    Background: Traditionally, pharmacy technicians have worked alongside pharmacists in community and hospital pharmacy. Changes within pharmacy provide opportunity for role expansion and with no apparent career pathway, there is a need to define the current pharmacy technician role and role in medicines optimisation. Aim: To capture the current roles of pharmacy technicians and identify how their future role will contribute to medicines optimisation. Methods: Following ethical approval and piloting, an online survey to ascertain pharmacy technicians’ views about their roles was undertaken. Recruitment took place in collaboration with the Association of Pharmacy Technicians UK. Data were exported to SPSS, data screened and descriptive statistics produced. Free text responses were analysed and tasks collated into categories reflecting the type of work involved in each task. Results: Responses received were 393 (28%, n = 1380). Results were organised into five groups: i.e., hospital, community, primary care, General Practitioner (GP) practice and other (which included HM Prison Service). Thirty tasks were reported as commonly undertaken in three or more settings and 206 (84.7%, n = 243) pharmacy technicians reported they would like to expand their role. Conclusions: Tasks core to hospital and community pharmacy should be considered for inclusion to initial education standards to reflect current practice. Post qualification, pharmacy technicians indicate a significant desire to expand clinically and managerially allowing pharmacists more time in patient-facing/clinical roles. PMID:28970452

  10. Training and qualification of health and safety technicians at a national laboratory

    International Nuclear Information System (INIS)

    Egbert, W.F.; Trinoskey, P.A.

    1994-10-01

    Over the last 30 years, Lawrence Livermore National Laboratory (LLNL) has successfully implemented the concept of a multi-disciplined technician. LLNL Health and Safety Technicians have responsibilities in industrial hygiene, industrial safety, health physics, as well as fire, explosive, and criticality safety. One of the major benefits to this approach is the cost-effective use of workers who display an ownership of health and safety issues which is sometimes lacking when responsibilities are divided. Although LLNL has always promoted the concept of a multi-discipline technician, this concept is gaining interest within the Department of Energy (DOE) community. In November 1992, individuals from Oak Ridge Institute of Science and Education (ORISE) and RUST Geotech, joined by LLNL established a committee to address the issues of Health and Safety Technicians. In 1993, the DOE Office of Environmental, Safety and Health, in response to the Defense Nuclear Facility Safety Board Recommendation 91-6, stated DOE projects, particularly environmental restoration, typically present hazards other than radiation such as chemicals, explosives, complex construction activities, etc., which require additional expertise by Radiological Control Technicians. They followed with a commitment that a training guide would be issued. The trend in the last two decades has been toward greater specialization in the areas of health and safety. In contrast, the LLNL has moved toward a generalist approach integrating the once separate functions of the industrial hygiene and health physics technician into one function

  11. New Zealand dental technicians and continuing education: findings from a qualitative survey.

    Science.gov (United States)

    Anderson, Vivienne R; Pang, Lilian C Y; Aarts, John M

    2012-06-01

    Under the 2003 Health Practitioners Competence Assurance (HPCA) Act, New Zealand registered dental technicians are subject to mandatory Continuing Professional Development (CPD) requirements. Internationally, little published literature has examined dental technicians' perspectives of CPD and CPD needs, and there is no published literature relating to the New Zealand context. Available research highlights the importance of CPD for maintaining high professional standards, ensuring patient safety, allowing dental technicians to keep abreast of current research and technological advances, fostering peer networks, and promoting job satisfaction. In 2009, an online open-ended questionnaire was developed to examine New Zealand dental and clinical dental technicians' perspectives of CPD and their perceived CPD needs. In total, 45 New Zealand registered dental technicians responded. Questionnaire responses provided rich qualitative insights into dental technicians' wide-ranging perceptions of CPD, factors that make CPD involvement more or less difficult and more or less desirable, and ways in which CPD access and relevance might be improved. This paper discusses the survey findings in the light of the existing literature on CPD and in relation to the unique New Zealand regulatory environment. It highlights the factors which respondents identified as shaping their CPD decisions, barriers to CPD engagement, perceived CPD needs, suggestions as to how the current CPD system could be improved, and areas for future research.

  12. Pharmacist and Technician Perceptions of Tech-Check-Tech in Community Pharmacy Practice Settings.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2018-04-01

    Tech-check-tech (TCT) is a practice model in which pharmacy technicians with advanced training can perform final verification of prescriptions that have been previously reviewed for appropriateness by a pharmacist. Few states have adopted TCT in part because of the common view that this model is controversial among members of the profession. This article aims to summarize the existing research on pharmacist and technician perceptions of community pharmacy-based TCT. A literature review was conducted using MEDLINE (January 1990 to August 2016) and Google Scholar (January 1990 to August 2016) using the terms "tech* and check," "tech-check-tech," "checking technician," and "accuracy checking tech*." Of the 7 studies identified we found general agreement among both pharmacists and technicians that TCT in community pharmacy settings can be safely performed. This agreement persisted in studies of theoretical TCT models and in studies assessing participants in actual community-based TCT models. Pharmacists who had previously worked with a checking technician were generally more favorable toward TCT. Both pharmacists and technicians in community pharmacy settings generally perceived TCT to be safe, in both theoretical surveys and in surveys following actual TCT demonstration projects. These perceptions of safety align well with the actual outcomes achieved from community pharmacy TCT studies.

  13. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  14. Evaluation of the biogas potential using in the equipment utilized in milk production systems; Avaliacao do potencial do emprego do biogas nos equipamentos utilizados em sistemas de producao de leite

    Energy Technology Data Exchange (ETDEWEB)

    Hardoim, Paulo Cesar; Goncalves, Adriano Dicesar M.A. [Lavras Univ. Federal, MG (Brazil). Dept. de Engenharia

    2000-07-01

    The technology of the anaerobic digestion has been checked as one of the most efficient in the treatment of the dejection of bovine, however, the employment of the biogas as source of energy for the operation of the equipment still finds limitations of technological order. The present work evaluated, the great potential of the treatment anaerobic of the residues of bovine destined the production of milk as source energy renewably , inside of a concept of maintainable development and production rationalization without aggression to the Middle-Atmosphere. It also verified that technology is adapted as conservation strategy and efficient energy use. The employment of the anaerobic digestion in the treatment of the dejection is possible and desirable, once it contributes to preservation of the environment, it makes possible the modern confinement systems and it reduces the production cost. The residues of milk cows produced, can be used as resources of supplies, so much of energy as of fertilizer. In a confinement of 100 cows, a biodigester can produce a volume of 118 m{sup 3} of biogas. Volume this enough one to work a generating group of 15 kVa and this to assist with electric energy the demand of the milk installation and bomb of water. The total demand of biogas can working with these equipment is esteemed in 85,3m{sup 3} of biogas, what can be supplied with rest by the biodigester. (author)

  15. Understanding Emissions from Control-Related Equipment used in Oil and Gas Production Operations to Support EPA’s Air Quality Modeling of Ozone Non-attainment Areas

    Science.gov (United States)

    Oil and gas production has increased significantly in the United States over the past ten years. Improperly maintained and controlled oil and gas extraction and production (E&P) processes have the potential to emit significant amounts of pollutants that can impact human health an...

  16. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  17. Evaluation of the use of personal protective equipment in radiodiagnostic services in Sergipe

    International Nuclear Information System (INIS)

    Santos, Lucas R. dos; Oliveira, Celso A.; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    The theme ionizing radiation is frequently associated with danger. Therefore this subject induces to think about accessories to personal protection. These accessories can contain metal heavy (as example, lead) so that we have an efficient protection. Our analysis was done with the main objective of evidence that is not enough the radiodiagnostic services have personal protective equipment to disposal to the radiology technicians have an efficient protection, because the procedures with ionizing radiation will be safe only with the use accomplish of the security procedures and of adequate use and storing of personal protective equipment. In our analysis the accessories in question were the lead rubber X-ray protection aprons and thyroid gland protectors. We have tested these accessories through of a similar methodology utilized to checking the half-value layer of the X-ray units. It was investigated also the importance given to use of these accessories by the radiology technicians. (author)

  18. Determination of the worst case for cleaning validation of equipment used in the radiopharmaceutical production of lyophilized reagents for {sup 99m}Tc labelling

    Energy Technology Data Exchange (ETDEWEB)

    Porto, Luciana Valeria Ferrari Machado; Fukumori, Neuza Taeko Okasaki; Matsuda, Margareth Mie Nakamura, E-mail: luciana.porto@anvisa.gov.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2016-01-15

    Cleaning validation, a requirement of the current Good Manufacturing Practices (cGMP) for Drugs, consists of documented evidence that cleaning procedures are capable of removing residues to predetermined acceptance levels. This report describes a strategy for the selection of the worst case product for the production of lyophilized reagents (LRs) for labeling with {sup 99m}Tc from the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/Sao Paulo). The strategy is based on the calculation of a 'worst case index' that incorporates information about drug solubility, cleaning difficulty, and occupancy rate in the production line. It allowed a reduction in the required number of validations considering the possible manufacturing flow of a given product and the subsequent flow, thus facilitating the process by reducing operation time and cost. The products identified as 'worst case' were LRs PUL-TEC and MIBI-TEC. (author). (author)

  19. Determination of the worst case for cleaning validation of equipment used in the radiopharmaceutical production of lyophilized reagents for 99mTc labelling

    International Nuclear Information System (INIS)

    Porto, Luciana Valeria Ferrari Machado; Fukumori, Neuza Taeko Okasaki; Matsuda, Margareth Mie Nakamura

    2016-01-01

    Cleaning validation, a requirement of the current Good Manufacturing Practices (cGMP) for Drugs, consists of documented evidence that cleaning procedures are capable of removing residues to predetermined acceptance levels. This report describes a strategy for the selection of the worst case product for the production of lyophilized reagents (LRs) for labeling with 99m Tc from the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/Sao Paulo). The strategy is based on the calculation of a 'worst case index' that incorporates information about drug solubility, cleaning difficulty, and occupancy rate in the production line. It allowed a reduction in the required number of validations considering the possible manufacturing flow of a given product and the subsequent flow, thus facilitating the process by reducing operation time and cost. The products identified as 'worst case' were LRs PUL-TEC and MIBI-TEC. (author). (author)

  20. Project scheduling with resources constraints: application in the equipment production for the oil industry; Scheduling de projetos com restricao de recursos: aplicacao na producao de equipamentos para a industria de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Carolina A.O.; Ferreira Filho, Virgilio J.M. [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE)

    2008-07-01

    One of the essential steps in the main scope Project Management is the Time Management made by the planning and control of the project schedule. In this work is presented the resource constrained scheduling problem beyond its mathematical formulation and a review of papers about this issue. In sequence is presented a practical example of this model considering a simplified model of an engineering project schedule of oil production equipment. The results obtained with the model application are shown and the conclusions about the work with resource constrained scheduling problems. (author)

  1. Communication received from the Member States of the European Community regarding the provision of certain additional information on production, inventories and international transfers of nuclear material and on exports of certain relevant equipment and non-nuclear material

    International Nuclear Information System (INIS)

    1992-12-01

    The document reproduces the text of the note verbale received by the Director General on 30 November 1992 from the Permanent Missions to the Agency of Belgium, Denmark, France, Germany, Greece, Ireland, Italy, Luxembourg, Netherlands, Portugal, Spain and the United Kingdom of Great Britain and Northern Ireland, relating to the provision of certain additional information on production, inventories and international transfer of nuclear material and on exports of certain relevant equipment and non-nuclear material. The note verbale dated 23 November 1992, received by the Director General from the Commission of the European Communities and relating to the same subject, is reproduced as well

  2. Procurement strategic analysis of nuclear safety equipment

    International Nuclear Information System (INIS)

    Wu Caixia; Yang Haifeng; Li Xiaoyang; Li Shixin

    2013-01-01

    The nuclear power development plan in China puts forward a challenge on procurement of nuclear safety equipment. Based on the characteristics of the procurement of nuclear safety equipment, requirements are raised for procurement process, including further clarification of equipment technical specification, establishment and improvement of the expert database of the nuclear power industry, adoption of more reasonable evaluation method and establishment of a unified platform for nuclear power plants to procure nuclear safety equipment. This paper makes recommendation of procurement strategy for nuclear power production enterprises from following aspects, making a plan of procurement progress, dividing procurement packages rationally, establishing supplier database through qualification review and implementing classified management, promoting localization process of key equipment continually and further improving the system and mechanism of procurement of nuclear safety equipment. (authors)

  3. 7 CFR 58.626 - Packaging equipment.

    Science.gov (United States)

    2010-01-01

    ... containers with frozen desserts shall be constructed so that all product contact surfaces shall be of... Standards for Equipment for Packaging Frozen Desserts and Cottage Cheese. Quality Specifications for Raw...

  4. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  5. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  6. HEMATOLOGICAL INDICES IN AUTOMOTIVE TECHNICIANS IN NNEWI, SOUTH-EAST NIGERIA.

    Science.gov (United States)

    Ibeh, Nancy; Aneke, John; Okocha, Chide; Nkwazema, Amobi

    2015-01-01

    Occupational exposure to petroleum products is known to be associated with a number of health risks as well as adverse effects on haematological indices. To evaluate the effect of exposure to petroleum products on haematological parameters in automobile mechanics in Nnewi, south-east Nigeria. Fifty (50) automobile technicians and 50 healthy controls participated in the study. Full blood count was performed for each participant using the automated Sysmex haemocytometer (Model PCE 210) while data analysis was done using the SPSS (statistical package for social sciences) version 16 computer soft ware (Chicago, IL, Inc.). Results were expressed as frequencies, means and standard deviations; comparison of haematological parameters was made between subjects and controls and at different durations of exposure using the students' t-test and analysis of variance (ANOVA), respectively. The level of statistical significance was p < 0.05 (at 95% CI). Ethical approval was obtained from the Institutional review board and all participants gave informed consent. There red blood cell count (RBC) and haematocrit were significantly lower while the platelet count was significantly higher in test subjects compared with controls (p values; 0.04, 0.03 and 0.01, respectively). Correspondingly, the mean cell volume (MCV) and mean cell haemoglobin (MCH) were significantly lower in test subjects compared with controls (p = 0.62 and 0.03, respectively). The red cell count, MCV and platelet count significantly decreased with increasing duration of work exposure (p = 0.001, respectively). Occupational exposure to petroleum products adversely affects blood counts, with a significant decrease in RBC, MCV and platelet count as duration of exposure increases.

  7. Transfer of Escherichia coli O157:H7 from equipment surfaces to fresh-cut leafy greens during processing in a model pilot-plant production line with sanitizer-free water.

    Science.gov (United States)

    Buchholz, Annemarie L; Davidson, Gordon R; Marks, Bradley P; Todd, Ewen C D; Ryser, Elliot T

    2012-11-01

    Escherichia coli O157:H7 contamination of fresh-cut leafy greens has become a public health concern as a result of several large outbreaks. The goal of this study was to generate baseline data for E. coli O157:H7 transfer from product-inoculated equipment surfaces to uninoculated lettuce during pilot-scale processing without a sanitizer. Uninoculated cored heads of iceberg and romaine lettuce (22.7 kg) were processed using a commercial shredder, step conveyor, 3.3-m flume tank with sanitizer-free tap water, shaker table, and centrifugal dryer, followed by 22.7 kg of product that had been dip inoculated to contain ∼10(6), 10(4), or 10(2) CFU/g of a four-strain avirulent, green fluorescent protein-labeled, ampicillin-resistant E. coli O157:H7 cocktail. After draining the flume tank and refilling the holding tank with tap water, 90.8 kg of uninoculated product was similarly processed and collected in ∼5-kg aliquots. After processing, 42 equipment surface samples and 46 iceberg or 36 romaine lettuce samples (25 g each) from the collection baskets were quantitatively examined for E. coli O157:H7 by direct plating or membrane filtration using tryptic soy agar containing 0.6% yeast extract and 100 ppm of ampicillin. Initially, the greatest E. coli O157:H7 transfer was seen from inoculated lettuce to the shredder and conveyor belt, with all equipment surface populations decreasing 90 to 99% after processing 90.8 kg of uncontaminated product. After processing lettuce containing 10(6) or 10(4) E. coli O157:H7 CFU/g followed by uninoculated lettuce, E. coli O157:H7 was quantifiable throughout the entire 90.8 kg of product. At an inoculation level of 10(2) CFU/g, E. coli O157:H7 was consistently detected in the first 21.2 kg of previously uninoculated lettuce at 2 to 3 log CFU/100 g and transferred to 78 kg of product. These baseline E. coli O157:H7 transfer results will help determine the degree of sanitizer efficacy required to better ensure the safety of fresh-cut leafy

  8. Clinical support role for a pharmacy technician within a primary care resource center.

    Science.gov (United States)

    Fera, Toni; Kanel, Keith T; Bolinger, Meghan L; Fink, Amber E; Iheasirim, Serah

    2018-02-01

    The creation of a clinical support role for a pharmacy technician within a primary care resource center is described. In the Primary Care Resource Center (PCRC) Project, hospital-based care transition coordination hubs staffed by nurses and pharmacist teams were created in 6 independent community hospitals. At the largest site, patient volume for targeted diseases challenged the ability of the PCRC pharmacist to provide expected elements of care to targeted patients. Creation of a new pharmacy technician clinical support role was implemented as a cost-effective option to increase the pharmacist's efficiency. The pharmacist's work processes were reviewed and technical functions identified that could be assigned to a specially trained pharmacy technician under the direction of the PCRC pharmacist. Daily tasks performed by the pharmacy technician included maintenance of the patient roster and pending discharges, retrieval and documentation of pertinent laboratory and diagnostic test information from the patient's medical record, assembly of patient medication education materials, and identification of discrepancies between disparate systems' medication records. In the 6 months after establishing the PCRC pharmacy technician role, the pharmacist's completion of comprehensive medication reviews (CMRs) for target patients increased by 40.5% ( p = 0.0223), driven largely by a 42.4% ( p technician to augment pharmacist care in a PCRC team extended the reach of the pharmacist and allowed more time for the pharmacist to engage patients. Technician support enabled the pharmacist to complete more CMRs and reduced the time required for chart reviews. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Internet treatment for depression: a randomized controlled trial comparing clinician vs. technician assistance.

    Science.gov (United States)

    Titov, Nickolai; Andrews, Gavin; Davies, Matthew; McIntyre, Karen; Robinson, Emma; Solley, Karen

    2010-06-08

    Internet-based cognitive behavioural therapy (iCBT) for depression is effective when guided by a clinician, less so if unguided. Would guidance from a technician be as effective as guidance from a clinician? Randomized controlled non-inferiority trial comparing three groups: Clinician-assisted vs. technician-assisted vs. delayed treatment. Community-based volunteers applied to the VirtualClinic (www.virtualclinic.org.au) research program, and 141 participants with major depressive disorder were randomized. Participants in the clinician- and technician-assisted groups received access to an iCBT program for depression comprising 6 online lessons, weekly homework assignments, and weekly supportive contact over a treatment period of 8 weeks. Participants in the clinician-assisted group also received access to a moderated online discussion forum. The main outcome measures were the Beck Depression Inventory (BDI-II) and the Patient Health QUESTIONnaire-9 Item (PHQ-9). Completion rates were high, and at post-treatment, both treatment groups reduced scores on the BDI-II (ptechnician-assisted groups respectively, and on the PHQ-9, were 1.54 and 1.60 respectively. At 4-month follow-up participants in the technician group had made further improvements and had significantly lower scores on the PHQ-9 than those in the clinician group. A total of approximately 60 minutes of clinician or technician time was required per participant during the 8-week treatment program. Both clinician- and technician-assisted treatment resulted in large effect sizes and clinically significant improvements comparable to those associated with face-to-face treatment, while a delayed treatment control group did not improve. These results provide support for large scale trials to determine the clinical effectiveness and acceptability of technician-assisted iCBT programs for depression. This form of treatment has potential to increase the capacity of existing mental health services. Australian New

  10. The practical training of students - x-ray technicians and requirements to mentors in clinical bases

    International Nuclear Information System (INIS)

    Gagova, P; Boninska, N.; Jovchev, D.

    2012-01-01

    Full text: Introduction: Training of X-ray technicians in Bulgaria takes place in the Medical Colleges to Medical Universities. It's purpose is providing professional training of students in the area of diagnostic imaging, nuclear medicine and radiotherapy. Practical training is based on the scientific and theoretical knowledge and skills and is organized in pedagogic environment, adequate to regularities for a gradual formation of practical skills and habits. The practical training and pre-graduation internship are performed in 1895 from total of 3810 hours, which represents about fifty percent of all training of X-ray technicians. Students are in groups of 2-4 students. Practical training is organized, accomplished and monitored by the teacher training practice with the help of a mentor in the clinical base. Purpose: To present the tasks of practical training of students - X-ray technicians and the requirements for the personal characteristics and activity of mentors. Materials and methods: Documentary method has been used. Literature and normative documents related to the practical training of students in 'X-ray technician' of Medical Colleges have been studied. The job descriptions of senior clinical X-ray technicians have been examined carefully. Results: By analyzing literature sources, we have structured the tasks of practical training and pre-graduation internship of students - X-ray technicians, also we have described the requirements for personal qualities of mentors and systematize the activities they perform. Conclusion: Practical training plays an important role in adaptation of young X-ray technicians to the conditions of medical work, improving their skills and habits, and to the development of specific practical skills for being able to respond to emergency conditions and to solve complicated practical situations. The mentor is the supervisor and the controller of interns who helps this happen through his own example, qualities and attitudes towards

  11. An in-depth examination into pharmacy technician worklife through an organizational behavior framework.

    Science.gov (United States)

    Desselle, Shane P

    2016-01-01

    Pharmacy technicians are a vital part of the health care workforce. Little is known about perceptions of their own work environment that would engender more effective recruitment, retention, and management strategies by pharmacists and employers. The purpose of this study was to gain a greater understanding of certified pharmacy technician worklife. Specific objectives included the identification of themes of worklife phenomena to assist with the development of appropriate responses by other pharmacy stakeholders and to ascertain the contribution of various factors engendering or discouraging career commitment of pharmacy technicians. Semi-structured in-depth interviews were carried out with a convenience sample of pharmacy technicians in one U.S. state, who varied by their work settings and level of experience. The interview guide and corresponding participant responses were framed from around an organizational cultural basis rooted in organizational behavior theory. Notes from the interviews were analyzed thematically using directed content analysis. Four primary themes emerged, including: career impetus, job responsibilities, quality of work life, and equitable partnership. The data revealed pharmacy technicians' need for self-actualization and recognition of the value they bring to the organization. The participants identified primary responsibilities that contribute to their sense of worth and those that if not managed adequately potentially detract from their well-being and effectiveness. Findings in regard to rate of pay corroborate previous work on wages as both an intrinsic and extrinsic motivator. Pharmacy technicians seek equity among each other (their peers) and in a mutually beneficial relationship with their employing organization. This study provides the impetus for interventions and further study that should serve to enhance pharmacy technician effectiveness, quality of work life, and longevity in an emerging profession. Copyright © 2015 Elsevier

  12. Fault detection in the electrical equipment of the artificial system, used for the oil production in marine platforms; Deteccion de fallas en los equipos electricos del sistema artificial, utilizado para la produccion de petroleo en plataformas marinas

    Energy Technology Data Exchange (ETDEWEB)

    Vargas H, Vicente; Rosales S, Inocente [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Pimentel M, Jorge [Petroleos Mexicanos (Mexico)

    2007-07-01

    At present, PEMEX is using new artificial pumping systems for the production of oil, specifically the Electro Centrifugal Pumping system (ECP). Nevertheless, during the operation of the (ECP) system problems by the failure of their electrical components have appeared, mainly of the equipment installed within the well. The faults have resulted in an increased cost for the diminution in the production and the maintenance cost of the remedial work. The maintenance personnel have procedures to perform verification tests of the conditions of the bottom electrical equipment. But, in the case of an electrical failure of the equipment, its location cannot be determined, since they are installed at 3,600 m from the production wellhead. In accordance with the former, the Instituto de Investigaciones Electricas proposed the application of the reflectometry technique in the time domain, to complement the maintenance procedures. This technique is a very useful diagnosis tool of the electrical equipment, which helps in the decision making of the maneuvers of preventive and corrective maintenance to be followed, with the consequent saving of resources. [Spanish] Actualmente, PEMEX esta utilizando nuevos sistemas artificiales de bombeo para la produccion de petroleo, en especifico el Sistema de Bombeo Electrocentrifugo (BEC). Sin embargo, durante la operacion del Sistema BEC se han presentado problemas por la falla de sus componentes electricos, sobre todo del equipo instalado dentro del pozo. Las fallas han resultado con un costo elevado por la disminucion en la produccion y por los trabajos de mantenimiento correctivo. El personal de mantenimiento cuenta con procedimientos para realizar pruebas de verificacion del estado de los equipos electricos de fondo. Pero, en el caso de una falla electrica de los equipos, no se puede determinar su ubicacion, dado que se instalan a 3,600 m del cabezal del pozo de produccion. De acuerdo con lo anterior, el Instituto de Investigaciones

  13. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  14. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  15. Determination of trace elements in coffee beans by XRF spectrometer equipped with polarization optics and its application to identification of their production area

    International Nuclear Information System (INIS)

    Akamine, Takao; Otaka, Akiko; Nakai, Izumi; Hokura, Akiko; Ito, Yuji

    2010-01-01

    The production area of coffee beans becomes a brand name, which gives reputations for the products, which is related to the price. This leads to room for mislabeling the products by unscrupulous market dealers. A rapid and easy method for the analysis of trace-element composition of coffee beans, which could be a good indicator of their production area, was studied in the present work. Coffee beans of 6 different regions (Brazil, Colombia, Vietnam, Indonesia, Tanzania, Guatemala) were analyzed by using a highly sensitive X-ray fluorescence spectrometer with three dimensional polarization optics. The experimental conditions were optimized so as to analyze 6 elements (Mn, Fe, Ni, Rb, Sr, Ba) in coffee beans, and linear calibration curves were obtained for the quantitative analysis of those elements. The analytical results were used in principal-component analysis to classify the coffee beans according to the geographical origin, which results in a successful characterization of the 6 production areas. It is found that roasted beans can be used with the same criterion as their green beans. Consequently, a rapid and easy way for the characterization of the geographic origin of coffee beans has been established in this study. (author)

  16. Design of China Leading Energy Efficiency Program (LEP) for equipment and appliances and comparative study of international experience on super-efficient products

    Science.gov (United States)

    Liang, Xiuying; Zhu, Chunyan

    2017-11-01

    With rising global emphasizes on climate change and sustainable development, how to accelerate the transformation of energy efficiency has become an important question. Designing and implementing energy-efficiency policies for super-efficient products represents an important direction to achieve breakthroughs in the field of energy conservation. On December 31, 2014, China’s National Development and Reform Commission (NDRC) jointly six other ministerial agencies launched China Leading Energy Efficiency Program (LEP), which identifies top efficiency models for selected product categories. LEP sets the highest energy efficiency benchmark. Design of LEP took into consideration of how to best motivate manufacturers to accelerate technical innovation, promote high efficiency products. This paper explains core elements of LEP, such as objectives, selection criteria, implementation method and supportive policies. It also proposes recommendations to further improve LEP through international policy comparison with Japan’s Top Runner Program, U.S. Energy Star Most Efficient, and SEAD Global Efficiency Medal.

  17. Life cycle assessment of post-consumer plastics production from waste electrical and electronic equipment (WEEE) treatment residues in a Central European plastics recycling plant

    International Nuclear Information System (INIS)

    Wäger, Patrick A.; Hischier, Roland

    2015-01-01

    Plastics play an increasingly important role in reaching the recovery and recycling rates defined in the European WEEE Directive. In a recent study we have determined the life cycle environmental impacts of post-consumer plastics production from mixed, plastics-rich WEEE treatment residues in the Central European plant of a market-leading plastics recycler, both from the perspective of the customers delivering the residues and the customers buying the obtained post-consumer recycled plastics. The results of our life cycle assessments, which were extensively tested with sensitivity analyses, show that from both perspectives plastics recycling is clearly superior to the alternatives considered in this study (i.e. municipal solid waste incineration (MSWI) and virgin plastics production). For the three ReCiPe endpoint damage categories, incineration in an MSWI plant results in an impact exceeding that of the examined plastics recycling facility each by about a factor of 4, and the production of virgin plastics has an impact exceeding that of the post-consumer recycled (PCR) plastics production each by a factor of 6–10. On a midpoint indicator level the picture is more differentiated, showing that the environmental impacts of the recycling options are lower by 50% and more for almost all impact factors. While this provides the necessary evidence for the environmental benefits of plastics recycling compared to existing alternatives, it can, however, not be taken as conclusive evidence. To be conclusive, future research will have to address the fate of hazardous substances in the outputs of such recycling systems in more detail. - Highlights: • LCA of plastics production from plastics-rich WEEE treatment residues • Multiple stakeholder perspectives addressed via different research questions • Plastics production from WEEE treatment residues clearly superior to alternatives • Robust results as demonstrated by extensive sensitivity analyses

  18. Life cycle assessment of post-consumer plastics production from waste electrical and electronic equipment (WEEE) treatment residues in a Central European plastics recycling plant

    Energy Technology Data Exchange (ETDEWEB)

    Wäger, Patrick A., E-mail: patrick.waeger@empa.ch; Hischier, Roland

    2015-10-01

    Plastics play an increasingly important role in reaching the recovery and recycling rates defined in the European WEEE Directive. In a recent study we have determined the life cycle environmental impacts of post-consumer plastics production from mixed, plastics-rich WEEE treatment residues in the Central European plant of a market-leading plastics recycler, both from the perspective of the customers delivering the residues and the customers buying the obtained post-consumer recycled plastics. The results of our life cycle assessments, which were extensively tested with sensitivity analyses, show that from both perspectives plastics recycling is clearly superior to the alternatives considered in this study (i.e. municipal solid waste incineration (MSWI) and virgin plastics production). For the three ReCiPe endpoint damage categories, incineration in an MSWI plant results in an impact exceeding that of the examined plastics recycling facility each by about a factor of 4, and the production of virgin plastics has an impact exceeding that of the post-consumer recycled (PCR) plastics production each by a factor of 6–10. On a midpoint indicator level the picture is more differentiated, showing that the environmental impacts of the recycling options are lower by 50% and more for almost all impact factors. While this provides the necessary evidence for the environmental benefits of plastics recycling compared to existing alternatives, it can, however, not be taken as conclusive evidence. To be conclusive, future research will have to address the fate of hazardous substances in the outputs of such recycling systems in more detail. - Highlights: • LCA of plastics production from plastics-rich WEEE treatment residues • Multiple stakeholder perspectives addressed via different research questions • Plastics production from WEEE treatment residues clearly superior to alternatives • Robust results as demonstrated by extensive sensitivity analyses.

  19. A Grounded Theory Study of Aircraft Maintenance Technician Decision-Making

    Science.gov (United States)

    Norcross, Robert

    Aircraft maintenance technician decision-making and actions have resulted in aircraft system errors causing aircraft incidents and accidents. Aircraft accident investigators and researchers examined the factors that influence aircraft maintenance technician errors and categorized the types of errors in an attempt to prevent similar occurrences. New aircraft technology introduced to improve aviation safety and efficiency incur failures that have no information contained in the aircraft maintenance manuals. According to the Federal Aviation Administration, aircraft maintenance technicians must use only approved aircraft maintenance documents to repair, modify, and service aircraft. This qualitative research used a grounded theory approach to explore the decision-making processes and actions taken by aircraft maintenance technicians when confronted with an aircraft problem not contained in the aircraft maintenance manuals. The target population for the research was Federal Aviation Administration licensed aircraft and power plant mechanics from across the United States. Nonprobability purposeful sampling was used to obtain aircraft maintenance technicians with the experience sought in the study problem. The sample population recruitment yielded 19 participants for eight focus group sessions to obtain opinions, perceptions, and experiences related to the study problem. All data collected was entered into the Atlas ti qualitative analysis software. The emergence of Aircraft Maintenance Technician decision-making themes regarding Aircraft Maintenance Manual content, Aircraft Maintenance Technician experience, and legal implications of not following Aircraft Maintenance Manuals surfaced. Conclusions from this study suggest Aircraft Maintenance Technician decision-making were influenced by experience, gaps in the Aircraft Maintenance Manuals, reliance on others, realizing the impact of decisions concerning aircraft airworthiness, management pressures, and legal concerns

  20. Biomass equipments. Dryers. Drying, crushing, agglomeration of agro-industrial products; Materiels pour la biomasse. Les secheurs, sechage, broyage, agglomeration de produits agro-industriels

    Energy Technology Data Exchange (ETDEWEB)

    Deur, O. [Promill (France)

    1997-12-31

    This paper describes the French Promill Company activity in the design and manufacturing of complete drying-crushing-agglomerating units for agro-industrial products (pulp of beet, lucerne, etc..). The paper focusses on the thermal and mechanical efficiency of the high temperature dryer and on the pulp granulating squeezer. (J.S.)

  1. Pharmacy technician-to-pharmacist ratios: a state-driven safety and quality decision.

    Science.gov (United States)

    Bess, D Todd; Carter, Jason; DeLoach, Lindsey; White, Carol L

    2014-01-01

    To discuss the policy of pharmacy technician-to-pharmacist ratios by comparing Florida as an example of legislative-led authority versus Tennessee as an example of board of pharmacy-led ruling. Over the past 2 years, the Florida legislature has debated the issue of pharmacy staffing ratios, initially leaving the Florida Board of Pharmacy with little authority to advocate for and enact safe technician staffing ratios. Anticipating this situation, the Tennessee Board of Pharmacy created rules to meet pharmacy staffing needs while protecting the authority of the pharmacist-in-charge and promoting patient safety. Before enacting rules, members of the board toured the state and talked about proposed rule changes with pharmacists. The final rule sets the pharmacy technician-to-pharmacist ratio at 2:1 but permits a 4:1 ratio based on public safety considerations and availability of at least two Certified Pharmacy Technicians. Pharmacists and leaders within the profession should conduct further research on appropriate and safe ratios of pharmacy technicians to pharmacists, with a focus on safety and quality of care.

  2. Patient- and Technician-Oriented Attitudes Toward Transcranial Magnetic Stimulation Devices.

    Science.gov (United States)

    Lonergan, Brady; Nguyen, Eliza; Lembo, Cara; Hinchman, Carrie; Morales, Oscar G; Press, Daniel Z; Pascual-Leone, Alvaro; Stern, Adam P

    2018-01-25

    Four transcranial magnetic stimulation (TMS) devices are currently approved for use in treatment-resistant depression. The authors present the first data-driven study examining the patient- and technician-experience using three of these distinct devices. A retrospective survey design with both patient and technician arms was utilized. The study population included patients who received TMS for treatment-resistant depression at the Berenson Allen Center for Noninvasive Brain Stimulation for the first time between 2013 and 2016 and technicians who worked in the program from 2009 to 2017. Statistical analysis included t tests and analyses of variance to assess differences between and across the multiple groups, respectively. Patients treated with the NeuroStar device reported greater confidence that the treatment was being performed correctly compared with those treated with the Magstim device. Conversely, with regard to tolerability, patients treated with the Magstim device reported less pain in the last week and less pain on average compared with those treated with the NeuroStar device. On average, technicians reported feeling that both the Magstim and NeuroStar devices were significantly easier to use than the Brainsway Deep TMS H-Coil device. Additionally, they found the former two devices to be more reliable and better tolerated. Furthermore, the technicians reported greater confidence in the Magstim and NeuroStar devices compared with the Brainsway Deep TMS H-Coil device and indicated that they would be more likely to recommend the two former devices to other treatment centers.

  3. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  4. The enforcement regulation for the law for radiation technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1985-01-01

    The ordinance is set up under the provisions of the law concerning radiation and x-ray technicians engaging in medical treatment, to enforce it. An application for the license of such a technician shall be filed according to the form prescribed, attached with a copy or an abstract of the census register of the applicant and a medical certificate of a doctor concerning whether the applicant is an insane, deaf or blind person, or a case of epidemic. The membership registration of such a technician shall include the number and date of the registration, the prefecture of his legal domicile, name birth date and sex distinction, the year and month of his success in the examination for such technicains, the items concerning the cancellation of the license or the suspension of the business, etc. The subjects of the examination for such technicians are physics, radiological physics, electrical engineering, chemistry, general basic medical science, radiological biology, photographing technology, treatment technics and others. An application for the examination for such technicians shall be filed to the Minister of Health and Welfare, attached with a personal history, a study certificate or a diploma of graduation, a photograph of the applicant and other specified documents. (Kubozono, M.)

  5. DNA damage and cytotoxicity in pathology laboratory technicians exposed to organic solvents

    Directory of Open Access Journals (Sweden)

    TATIANE DE AQUINO

    2016-03-01

    Full Text Available The aim of this study was to evaluate potential DNA damage and cytotoxicity in pathology laboratory technicians exposed to organic solvents, mainly xylene. Peripheral blood and buccal cells samples were collected from 18 technicians occupationally exposed to organic solvents and 11 non-exposed individuals. The technicians were sampled at two moments: Monday and Friday. DNA damage and cytotoxicity were evaluated using the Comet Assay and the Buccal Micronucleus Cytome assay. Fifteen subjects (83.5% of the exposed group to solvents complained about some symptom probably related to contact with vapours of organic solvents. DNA damage in the exposed group to solvents was nearly 2-fold higher on Friday than on Monday, and in both moments the individuals of this group showed higher levels of DNA damage in relation to controls. No statistical difference was detected in buccal cell micronucleus frequency between the laboratory technicians and the control group. However, in the analysis performed on Friday, technicians presented higher frequency (about 3-fold of karyolytic and apoptotic-like cells (karyorrhectic and pyknotic in relation to control group. Considering the damage frequency and the working time, a positive correlation was found in the exposed group to solvents (r=0.468; p=0.05. The results suggest that pathology laboratory workers inappropriately exposed to organic solvents have increased levels of DNA damage.

  6. Characterization of Low Back Pain in Pilots and Maintenance Technicians on a Commercial Airline.

    Science.gov (United States)

    Fajardo Rodriguez, Hugo A; Ortiz Mayorga, Viviana A

    2016-09-01

    Lower back pain (LBP) is the most common complaint worldwide and the leading cause of disability in the workplace. In Colombia there are no epidemiological data on low back pain in aviation. This study aimed to characterize lower back pain in pilots and maintenance technicians in a Colombian commercial airline. Information was collected from the total population in a Colombian commercial airline in Bogota during the period from 2011 to 2013 using a voluntary survey which requested demographics, occupational (LEST survey) factors, back pain, and chronic pain (chronic pain grade scale). The prevalence rate of LBP in pilot respondents was 71% and the factors associated previously have belonged to the military forces: occupational exposure to physical load and work time. Chronic low back pain was at a prevalence of 49%. The prevalence of LBP in maintenance technicians was 65%. Associated factors were again similar to military forces and included mental workload. Chronic pain had a prevalence of 65%. Factors associated with chronic low back pain were the technicians' time in office and physical load. The prevalence of lower back pain in pilots is similar to that presented in the airline world population. In the case of maintenance technicians, the prevalence was higher than those found in other similar groups, but very similar to prevalences presented in different business industries, including the transport sector. Fajardo Rodriguez HA, Ortiz Mayorga VA. Characterization of low back pain in pilots and maintenance technicians on a commercial airline. Aerosp Med Hum Perform. 2016; 87(9):795-799.

  7. Technician Consistency in Specular Microscopy Measurements: A "Real-World" Retrospective Analysis of a United States Eye Bank.

    Science.gov (United States)

    Rand, Gabriel M; Kwon, Ji Won; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2017-10-01

    To quantify consistency of endothelial cell density (ECD) measurements among technicians in a single US eye bank operating under typical operating conditions. In this retrospective analysis of 51 microscopy technicians using a semiautomated counting method on 35,067 eyes from July 2007 to May 2015, technician- and date-related marginal ECD effects were calculated using linear regression models. ECD variance was correlated with the number of specular microscopy technicians. Technician mean ECDs ranged from 2386 ± 431 to 3005 ± 560 cells/mm. Nine technicians had statistically and clinically significant marginal effects. Annual mean ECDs adjusted for changes in technicians ranged from 2422 ± 433 to 2644 ± 430 cells/mm. The period of 2007 to 2009 had statistically and clinically significant marginal effects. There was a nonstatistically significant association between the number of technicians and ECD standard deviation. There was significant ECD variability associated with specular microscopy technicians and with the date of measurement. We recommend that eye banks collect data related to laboratory factors that have been shown to influence ECD variability.

  8. Metabolic syndrome and occupation: Any association? Prevalence among auto technicians and school teachers in South West Nigeria.

    Science.gov (United States)

    Akintunde, Adeseye A; Oloyede, Taiwo W

    2017-11-01

    To determine occupational association with metabolic syndrome among auto technicians and school teachers. One hundred and sixty six subjects were selected for this study. Clinical data was obtained while laboratory investigations including plasma glucose and lipid profile were performed. Statistical analysis was done with SPSS 20.0. Pauto technicians. Mean serum triglycerides was significantly higher among auto-technicians compared to school teachers in this study. The prevalence of some conventional cardiovascular risk factors was significantly higher among auto-technicians compared to school teachers: Impaired blood glucose (9.6% vs. 1.2%, pauto-technicians. Based on the WHO and the Harmonized criteria, metabolic syndrome was more frequent among auto-technicians compared to school teachers. (8.4% vs. 1.2% and 19.3% vs. 7.2% respectively, pauto technicians despite their high level of physical activity, exertion and education compared to teachers. This may be related to the increased occupational exposure to organic and inorganic materials from dust particles, oil and oil related matter and particulate matter among auto technicians. Prompt definitive evaluation of this concept and appropriate health education to encourage safety mechanism can reduce this burden of metabolic syndrome among auto technicians in Nigeria. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  9. Life cycle assessment of post-consumer plastics production from waste electrical and electronic equipment (WEEE) treatment residues in a Central European plastics recycling plant.

    Science.gov (United States)

    Wäger, Patrick A; Hischier, Roland

    2015-10-01

    Plastics play an increasingly important role in reaching the recovery and recycling rates defined in the European WEEE Directive. In a recent study we have determined the life cycle environmental impacts of post-consumer plastics production from mixed, plastics-rich WEEE treatment residues in the Central European plant of a market-leading plastics recycler, both from the perspective of the customers delivering the residues and the customers buying the obtained post-consumer recycled plastics. The results of our life cycle assessments, which were extensively tested with sensitivity analyses, show that from both perspectives plastics recycling is clearly superior to the alternatives considered in this study (i.e. municipal solid waste incineration (MSWI) and virgin plastics production). For the three ReCiPe endpoint damage categories, incineration in an MSWI plant results in an impact exceeding that of the examined plastics recycling facility each by about a factor of 4, and the production of virgin plastics has an impact exceeding that of the post-consumer recycled (PCR) plastics production each by a factor of 6-10. On a midpoint indicator level the picture is more differentiated, showing that the environmental impacts of the recycling options are lower by 50% and more for almost all impact factors. While this provides the necessary evidence for the environmental benefits of plastics recycling compared to existing alternatives, it can, however, not be taken as conclusive evidence. To be conclusive, future research will have to address the fate of hazardous substances in the outputs of such recycling systems in more detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Training, abilities, role and responsibilities of the technician in treatment planning or 'dosimetrist' in radiotherapy

    International Nuclear Information System (INIS)

    Buchheit, Isabelle; Angles, Damien; Marchesi, Vincent; Fau, Pierre; Aubignac, Leone; Palisson, Jeremy; Lacornerie, Thomas; Baron, Pierre-Louis; Popoff, Romain; Llagostera, Camille; Buffard, Edwige; Sarrazin, Thierry; Le Du, Dominique; Estivalet, Andre; Tchong, Bruno; Marcie, Serge; Guerin, Lucie; Parent, Laure

    2013-09-01

    As the creation of treatment plans in radiotherapy (commonly named dosimetry) has become a crucial task in the treatment process, and has been historically performed by the medical physician, it may be delegated to other professionals and there is therefore a need of creation of a profession: the technician in treatment planning or dosimetrist. In order to better define this profession, its role and its education and training requirements, this document describes its role, its required knowledge, abilities and capacities (general knowledge, knowledge in anatomy, oncology and imagery, in radiation production, in ballistic and preparation, in radiotherapy, in breath-based feedback, in body irradiation, in radiation protection, in delimitation of organs at risk, and in administrative issues). The different training levels are indicated: initial training, continuous training, and validation of prior experience. The legal framework and organisational issues are addressed in terms of delegation and responsibility

  11. THE ROLE OF SCHOOL TECHNICIANS IN PROMOTING SCIENCE THROUGH PRACTICAL WORK

    Directory of Open Access Journals (Sweden)

    Anne T. Helliar

    2011-11-01

    Full Text Available This is a review of the role of practical work in UK’s secondary school science lessons, the impact that practical work has in the promotion of science, the challenges created through use of non-specialist science teachers and a possible additional role for science technicians. The paper considers how improved deployment of suitably experienced school science technicians and their recognition, by schools’ management, for their involvement in the delivery of training in the use of practical work, for less experienced teachers, could benefit schools and their students. This together with its companion paper endeavours to show how the more effective use of practical work and technicians can encourage more students to select science at higher, non-compulsory levels.

  12. The nuclear industry is looking for its technicians; Le nucleaire cherche ses techniciens

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, A

    2010-03-15

    With massive retirements planned up to 2015, the French nuclear industry wishes to recruit technicians for the operation and maintenance of its power plants. The French nuclear park represents 19 power plants with 58 reactors. The nuclear industry personnel represents 19000 people at EdF and about 20000 people from about 600 different service provider companies. Technician's salary ranges from 1500 to 2800 euros for experienced people, bonus not included. Before being operational, the French nuclear technicians have to follow a long training period in one of the 20 specialized and certified training centres. However, the training demand is so important that the industry suffers from a lack of instructors as well. (J.S.)

  13. Appendices to the guidebook on the education and training of technicians for nuclear power

    International Nuclear Information System (INIS)

    1989-10-01

    The current publication, a supplement to the IAEA Guidebook on the Education and Training of Technicians for Nuclear Power, in conjunction with which it should be read, aims to assist Member States, especially the developing countries which are in the process of implementing, or intending to implement, a nuclear power programme, to understand and meet their requirements for qualified technicians in the most effective and efficient manner. It specifically seeks to assist policy makers and planners, as well as those designing and implementing education and training programmes. The Guidebook and this TECDOC complement the IAEA Guidebook on Manpower Development for Nuclear Power, as well as the IAEA Guidebook on the Qualification of Nuclear Power Plant Operations Personnel. This TECDOC supplements the Guidebook with valuable information on the national experience of IAEA Member States in the education and training of technicians for nuclear power, as well as examples of such education and training from various Member States. Figs and tabs

  14. Does pneumoconiosis of dental technician cause to calcific pleural lesions? (Case report

    Directory of Open Access Journals (Sweden)

    Abdurrahman ŞENYİĞİT

    2009-03-01

    Full Text Available The articles about various pneumoconiosis in dental technicians who work in inconvenient conditions have been increasing in recent years. Exposure to dust and fume that occur during the dental procedure may play role in pneumoconiosis of dental technicians.A 53 years old male patient conveyed that he has worked in dental prosthesis procedures for 22 years (1968-1990.Environmental asbestosis was not established in the history of the case but there were calcified pleural plaques in the chest x-ray graphy.There were appearance of calcific asbest plaques in many section of thorax CT.A case of pneumoconiosis in dental technician who work in unadequate preventive conditions was reported in this paper. Probably ,exposure to the asbest fibers that occurs during the procedure of dental prosthesis were the main reason for developing calcific pleural lesions.

  15. Medication reconciliation and prescribing reviews by pharmacy technicians in a geriatric ward

    DEFF Research Database (Denmark)

    Buck, Thomas Croft; Gronkjaer, Louise Smed; Duckert, Marie-Louise

    2013-01-01

    OBJECTIVE: Incomplete medication histories obtained on hospital admission are responsible for more than 25% of prescribing errors. This study aimed to evaluate whether pharmacy technicians can assist hospital physicians' in obtaining medication histories by performing medication reconciliation an...... reconciliation and focused medication reviews. Further randomized, controlled studies including a larger number of patients are required to elucidate whether these observations are of significance and of importance for securing patient safety....... and prescribing reviews. A secondary aim was to evaluate whether the interventions made by pharmacy technicians could reduce the time spent by the nurses on administration of medications to the patients. METHODS: This observational study was conducted over a 7 week period in the geriatric ward at Odense...... University Hospital, Denmark. Two pharmacy technicians conducted medication reconciliation and prescribing reviews at the time of patients' admission to the ward. The reviews were conducted according to standard operating procedures developed by a clinical pharmacist and approved by the Head of the Geriatric...

  16. Oral health technicians in Brazilian primary health care: potentials and constraints.

    Science.gov (United States)

    Aguiar, Dulce Maria Lucena de; Tomita, Nilce Emy; Machado, Maria de Fátima Antero Sousa; Martins, Cleide Lavieri; Frazão, Paulo

    2014-07-01

    Different perspectives on the role of mid-level workers in health care might represent a constraint to health policies. This study aimed to investigate how different agents view the participation of oral health technicians in direct activities of oral healthcare with the goal of understanding the related symbolic dispositions. Theoretical assumptions related to inter-professional collaboration and conflicts in the field of healthcare were used for this analysis. A researcher conducted 24 in-depth interviews with general dental practitioners, oral health technicians and local managers. The concepts of Pierre Bourdieu supported the data interpretation. The results indicated inter-professional relations marked by collaboration and conflict that reflect an action space related to different perspectives of primary care delivery. They also unveiled the symbolic devices related to the participation of oral health technicians that represent a constraint to the implementation of oral health policy, thus reducing the potential of primary health care in Brazil.

  17. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  18. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  19. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  20. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  1. Equipment for the handling of thorium materials

    International Nuclear Information System (INIS)

    Heisler, S.W. Jr.; Mihalovich, G.S.

    1988-01-01

    The Feed Materials Production Center (FMPC) is the United States Department of Energy's storage facility for thorium. FMPC thorium handling and overpacking projects ensure the continued safe handling and storage of the thorium inventory until final disposition of the materials is determined and implemented. The handling and overpacking of the thorium materials requires the design of a system that utilizes remote handling and overpacking equipment not currently utilized at the FMPC in the handling of uranium materials. The use of remote equipment significantly reduces radiation exposure to personnel during the handling and overpacking efforts. The design system combines existing technologies from the nuclear industry, the materials processing and handling industry and the mining industry. The designed system consists of a modified fork lift truck for the transport of thorium containers, automated equipment for material identification and inventory control, and remote handling and overpacking equipment for material identification and inventory control, and remote handling and overpacking equipment for repackaging of the thorium materials

  2. Expanded pharmacy technician roles: Accepting verbal prescriptions and communicating prescription transfers.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2017-11-01

    As the role of the clinical pharmacist continues to develop and advance, it is critical to ensure pharmacists can operate in a practice environment and workflow that supports the full deployment of their clinical skills. When pharmacy technician roles are optimized, patient safety can be enhanced and pharmacists may dedicate more time to advanced clinical services. Currently, 17 states allow technicians to accept verbal prescriptions called in by a prescriber or prescriber's agent, or transfer a prescription order from one pharmacy to another. States that allow these activities generally put few legal limitations on them, and instead defer to the professional judgment of the supervising pharmacist whether to delegate these tasks or not. These activities were more likely to be seen in states that require technicians to be registered and certified, and in states that have accountability mechanisms (e.g., discipline authority) in place for technicians. There is little evidence to suggest these tasks cannot be performed safely and accurately by appropriately trained technicians, and the track record of success with these tasks spans four decades in some states. Pharmacists can adopt strong practice policies and procedures to mitigate the risk of harm from verbal orders, such as instituting read-back/spell-back techniques, or requiring the indication for each phoned-in medication, among other strategies. Pharmacists may also exercise discretion in deciding to whom to delegate these tasks. As the legal environment becomes more permissive, we foresee investment in more robust education and training of technicians to cover these activities. Thus, with the adoption of robust practice policies and procedures, delegation of verbal orders and prescription transfers can be safe and effective, remove undue stress on pharmacists, and potentially free up pharmacist time for higher-order clinical care. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    Science.gov (United States)

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  4. Carpal tunnel syndrome among laboratory technicians in relation to personal and ergonomic factors at work.

    Science.gov (United States)

    El-Helaly, Mohamed; Balkhy, Hanan H; Vallenius, Laura

    2017-11-25

    Work-related carpal tunnel syndrome (CTS) has been reported in different occupations, including laboratory technicians, so this study was carried out to determine the prevalence and the associated personal and ergonomic factors for CTS among laboratory technicians. A cross-sectional study was conducted among 279 laboratory technicians at King Fahd Hospital, Saudi Arabia, who filled in a self-administered questionnaire, including questions regarding their demographic criteria, occupational history, job tasks, workplace tools, ergonomic factors at work, and symptoms suggestive of CTS. Physical examinations and electrodiagnostic studies were carried out for those who had symptoms suggestive of CTS to confirm the diagnosis. Univariate and multivariate analysis were performed for both personal and physical factors in association with confirmed CTS among laboratory technicians. The prevalence of CTS among the laboratory technicians was 9.7% (27/279). The following were the statistically significant risk factors for CTS among them: gender (all cases of CTS were female, P=0.00), arm/hand exertion (OR: 7.96; 95% CI: 1.84-34.33), pipetting (OR: 7.27; 95% CI: 3.15-16.78), repetitive tasks (OR: 4.60; 95% CI: 1.39-15.70), using unadjustable chairs or desks (OR: 3.35; 95% CI: 1.23-9.15), and working with a biosafety cabinet (OR: 2.49; 95% CI: 1.11-5.59). CTS cases had significant longer work duration (17.9 ± 5.6 years) than CTS non-case (11.5 ± 7.4 yeas) with low OR (1.108). This study demonstrates some personal and ergonomic factors associated with CTS among the laboratory technicians, including female gender, arm/hand exertion, pipetting, repetitive tasks, working with a biosafety cabinet, and an unadjusted workstation.

  5. Technology for Increasing Geothermal Energy Productivity. Computer Models to Characterize the Chemical Interactions of Geothermal Fluids and Injectates with Reservoir Rocks, Wells, Surface Equipment

    International Nuclear Information System (INIS)

    Nancy Moller Weare

    2006-01-01

    This final report describes the results of a research program we carried out over a five-year (3/1999-9/2004) period with funding from a Department of Energy geothermal FDP grant (DE-FG07-99ID13745) and from other agencies. The goal of research projects in this program were to develop modeling technologies that can increase the understanding of geothermal reservoir chemistry and chemistry-related energy production processes. The ability of computer models to handle many chemical variables and complex interactions makes them an essential tool for building a fundamental understanding of a wide variety of complex geothermal resource and production chemistry. With careful choice of methodology and parameterization, research objectives were to show that chemical models can correctly simulate behavior for the ranges of fluid compositions, formation minerals, temperature and pressure associated with present and near future geothermal systems as well as for the very high PT chemistry of deep resources that is intractable with traditional experimental methods. Our research results successfully met these objectives. We demonstrated that advances in physical chemistry theory can be used to accurately describe the thermodynamics of solid-liquid-gas systems via their free energies for wide ranges of composition (X), temperature and pressure. Eight articles on this work were published in peer-reviewed journals and in conference proceedings. Four are in preparation. Our work has been presented at many workshops and conferences. We also considerably improved our interactive web site (geotherm.ucsd.edu), which was in preliminary form prior to the grant. This site, which includes several model codes treating different XPT conditions, is an effective means to transfer our technologies and is used by the geothermal community and other researchers worldwide. Our models have wide application to many energy related and other important problems (e.g., scaling prediction in petroleum

  6. A suitability study of the fission product phantom and the bottle manikin absorption phantom for calibration of in vivo bioassay equipment for the DOELAP accreditation testing program

    International Nuclear Information System (INIS)

    Olsen, P.C.; Lynch, T.P.

    1991-08-01

    Pacific Northwest laboratory (PNL) conducted an intercomparison study of the Fission Product phantom and the bottle manikin absorption (BOMAB) phantom for the US Department of Energy (DOE) to determine the consistency of calibration response of the two phantoms and their suitability for certification and use under a planned bioassay laboratory accreditation program. The study was initiated to determine calibration factors for both types of phantoms and to evaluate the suitability of their use in DOE Laboratory Accreditation Program (DOELAP) round-robin testing. The BOMAB was found to be more appropriate for the DOELAP testing program. 9 refs., 9 figs., 9 tabs

  7. Equipment for biomass. Dryers. Drying, crushing, aggregating of agro-industrial products; Materiels pour la biomasse, les secheurs, sechage, broyage, agglomeration de produits agro-industriels

    Energy Technology Data Exchange (ETDEWEB)

    Deur, O. [Promill, 28 - Serville (France)

    1997-12-31

    The French society Promill has developed complete units for the drying, crushing and aggregating of agro-industrial products (beet roots, agricultural wastes, lucerne, maize, etc.). Drying is conducted in a three-pass drum, using any type of fuel (fuel oil, gas, electric power, coal), and ensuring a thermal yield of 680 kCal/kg and ash emission rates complying with French and European legislation. Granulation is conducted with vapour addition, with a granulate flowrate reaching 15 T/h. Crushing is carried out in a hammer mill

  8. The validation of the Utrecht work engagement scale for emergency medical technicians in Gauteng

    Directory of Open Access Journals (Sweden)

    JLP Naudé

    2004-04-01

    Full Text Available The objectives of this study were to validate the Utrecht Work Engagement Scale (UWES for emergency medical technicians in the Gauteng Province of South Africa and to determine its construct equivalence and bias for different language groups. A cross-sectional survey design was used with a convenient sample (N = 318 of emergency medical technicians in Gauteng. The UWES and a biographical questionnaire were administered. A two-factor model of work engagement, consisting of Vigour/Dedication and Absorption was found. Exploratory factor analysis with target rotations confirmed the construct equivalence of the work engagement construct for white and black employees.

  9. Effect of individually tailored biopsychosocial workplace interventions on chronic musculoskeletal pain and stress among laboratory technicians

    DEFF Research Database (Denmark)

    Jay, Kenneth; Brandt, Mikkel; Hansen, Klaus

    2015-01-01

    BACKGROUND: Chronic musculoskeletal pain is prevalent among laboratory technicians and work-related stress may aggravate the problem. OBJECTIVES: This study investigated the effect of a multifaceted worksite intervention on pain and stress among laboratory technicians with chronic musculoskeletal......: neck, shoulder, lower and upper back, elbow, and hand at 10 week follow-up. The secondary outcome measure was stress assessed by Cohen´s perceived stress questionnaire. In addition, an explorative dose-response analysis was performed on the adherence to PCMT with pain and stress, respectively......, as outcome measures. RESULTS: A significant (P stress was observed (treatment by time P = 0.16). Exploratory analyses for each body...

  10. Academy of Nutrition and Dietetics: Scope of Practice for the Dietetic Technician, Registered.

    Science.gov (United States)

    2013-06-01

    The Scope of Practice for the Dietetic Technician, Registered provides standards and tools to guide competence in performing nutrition and dietetics practice. Composed of statutory and individual components, the DTR's scope of practice is determined by state statute and the DTR's education, training, credentialing, and demonstrated and documented competence in practice. The Scope of Practice for the Dietetic Technician, Registered reflects the Academy's position on the DTR scope of practice and the essential technical assistance role of the DTR in providing safe timely person-centered care for the delivery of quality food and nutrition services.

  11. Equipment Reliability Program in NPP Krsko

    International Nuclear Information System (INIS)

    Skaler, F.; Djetelic, N.

    2006-01-01

    Operation that is safe, reliable, effective and acceptable to public is the common message in a mission statement of commercial nuclear power plants (NPPs). To fulfill these goals, nuclear industry, among other areas, has to focus on: 1 Human Performance (HU) and 2 Equipment Reliability (EQ). The performance objective of HU is as follows: The behaviors of all personnel result in safe and reliable station operation. While unwanted human behaviors in operations mostly result directly in the event, the behavior flaws either in the area of maintenance or engineering usually cause decreased equipment reliability. Unsatisfied Human performance leads even the best designed power plants into significant operating events, which can be found as well-known examples in nuclear industry. Equipment reliability is today recognized as the key to success. While the human performance at most NPPs has been improving since the start of WANO / INPO / IAEA evaluations, the open energy market has forced the nuclear plants to reduce production costs and operate more reliably and effectively. The balance between these two (opposite) goals has made equipment reliability even more important for safe, reliable and efficient production. Insisting on on-line operation by ignoring some principles of safety could nowadays in a well-developed safety culture and human performance environment exceed the cost of electricity losses. In last decade the leading USA nuclear companies put a lot of effort to improve equipment reliability primarily based on INPO Equipment Reliability Program AP-913 at their NPP stations. The Equipment Reliability Program is the key program not only for safe and reliable operation, but also for the Life Cycle Management and Aging Management on the way to the nuclear power plant life extension. The purpose of Equipment Reliability process is to identify, organize, integrate and coordinate equipment reliability activities (preventive and predictive maintenance, maintenance

  12. 40 CFR 63.1434 - Equipment leak provisions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Equipment leak provisions. 63.1434... Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1434 Equipment leak provisions. (a) The owner or operator of each affected source shall comply with the HON equipment leak...

  13. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  14. Surface decontamination in the old storage shed number 99 of the General Plan of IPEN/CNEN-SP, containing production equipment of natural uranium hexafluoride (UF6), aiming at its decommissioning

    International Nuclear Information System (INIS)

    Almeida, Claudio C. de; Cambises, Paulo B.S.; Paiva, Julio E. de; Paiva, Julio E. de; Silva, Teresina M.; Rodrigues, Demerval L.

    2013-01-01

    This paper presents the steps adopted in the operation planned for the decontamination of surfaces in the old storage shed number 99 the general layout of the Energy Research and Nuclear IPEN-CNEN/SP, Brazil, and contained various types of equipment originating from production hexafluoride natural uranium (UF6). This operation involved the planning, training of operators of the facility, analysis of workplaces and radiometric surveys for monitoring of external radiation and surface contamination. The training involved the procedures for decontamination of surfaces, segregation of materials and practical procedures for individual monitoring of contamination outside of the body. Were also established rules for the transport of radioactive materials in the internal and external facility and release of material and sites already decontaminated

  15. Manufacture and maintenance of laboratory equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Chang Kyu; Hwang, Bong Ha; Lee, Jong Wha; Kim, Jong Kyun; Yeum, Ki Eon; Park, Myung Ku; Hong, Soon Eon; Choi, Ho Young; An, Dae Kyu; An, Choon; Park, In Won; Kim, Kyung Sik; Lee, Won Jae; Yoon, Ki Byung; Kim, Heung Woo; Lee, In Bae; Yeom, Jeong Hyun; Lee, Chul Ku; Sin, Keon Ju; Oh, Wan Ho; Seo, Yong Chil; Yang, Song Yeul; Lee, Young Soon; Choi, Byung Kwon; Chang, Kyung Duk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of request working to the machine shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the machine shop is to support the successful and convenient performance of the R and D by manufacture and maintenance of all sorts of laboratory equipment. 11 tabs., 3 figs. (Author) .new.

  16. Manufacture and maintenance of laboratory equipment

    International Nuclear Information System (INIS)

    Hwang, Chang Kyu; Hwang, Bong Ha; Lee, Jong Wha; Kim, Jong Kyun; Yeum, Ki Eon; Park, Myung Ku; Hong, Soon Eon; Choi, Ho Young; An, Dae Kyu; An, Choon; Park, In Won; Kim, Kyung Sik; Lee, Won Jae; Yoon, Ki Byung; Kim, Heung Woo; Lee, In Bae; Yeom, Jeong Hyun; Lee, Chul Ku; Sin, Keon Ju; Oh, Wan Ho; Seo, Yong Chil; Yang, Song Yeul; Lee, Young Soon; Choi, Byung Kwon; Chang, Kyung Duk

    1993-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of request working to the machine shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the machine shop is to support the successful and convenient performance of the R and D by manufacture and maintenance of all sorts of laboratory equipment. 11 tabs., 3 figs. (Author) .new

  17. Manufacture and maintenance of laboratory equipment

    International Nuclear Information System (INIS)

    Kim, Jong Kyun; Hwang, Chang Kyu; Hwang, Bong Ha; Lee, Jong Wha; Yeom, Ki Eon; Park, Myung Ku; Hong, Soon Hyeon; Choi, Ho Young; An, Dae Kyu; An, Choon; Park, In Won; Kim, Kyeong Sik; Lee, In Bae; Yeom, Jeong Heon; Lee, Chul Ku; Sin, Keon Ju; Oh, Wan Ho; Choi, Byung Kwon; Chang, Kyeong Duk; Lee, Young Soon

    1995-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of a request working to the Machine Shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the Machine Shop is to support the successful and convenient performance of the Research and development by manufacture and maintenance of all sorts of laboratory equipment. 12 tabs., 5 figs. (Author) .new

  18. Manufacture and maintenance of laboratory equipment

    International Nuclear Information System (INIS)

    Kim, J. K.; Whang, C. K.; Lee, J. H.; Youm, K. Y.; Hong, S. H.; Choi, H. Y.; An, C.; Park, I. W.; Kim, K. S.; Lee, W. J.; Yoon, K. B.; Kim, H. W.; Lee, I. B.; Lee, C. K.; Youm, J. H.; Oho, W. H.; Choi, B. K.; Jang, K. D.

    1996-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of a request working to the Machine Shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the Machine Shop is to support the successful and convenient performance of the R and D by manufacture and maintenance of all sorts of laboratory equipment. (author). 9 tabs., 12 figs

  19. Manufacture and maintenance of laboratory equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Kyun; Hwang, Chang Kyu; Hwang, Bong Ha; Lee, Jong Wha; Yeom, Ki Eon; Park, Myung Ku; Hong, Soon Hyeon; Choi, Ho Young; An, Dae Kyu; An, Choon; Park, In Won; Kim, Kyeong Sik; Lee, In Bae; Yeom, Jeong Heon; Lee, Chul Ku; Sin, Keon Ju; Oh, Wan Ho; Choi, Byung Kwon; Chang, Kyeong Duk; Lee, Young Soon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of a request working to the Machine Shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the Machine Shop is to support the successful and convenient performance of the Research and development by manufacture and maintenance of all sorts of laboratory equipment. 12 tabs., 5 figs. (Author) .new.

  20. Physical protection equipment study. Final report

    International Nuclear Information System (INIS)

    Haberman, W.

    1977-06-01

    This report summarizes the work performed by MITRE for the U.S. Nuclear Regulatory Commission. The major products of this effort are a Catalog of Physical Protection Equipment, a Guide for Evaluation of Physical Protection Equipment, a book of Reference Materials, and a set of guidelines for use in the development of a methodology for measuring levels of security system effectiveness. A summary of recommendations resulting from this study is also presented

  1. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  2. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  3. Mutations des roles techniques et formation. Etude documentaire (Changes in the Roles and Education of Technicians. Documentary Study).

    Science.gov (United States)

    Pinard, Helene

    Drawing from research conducted in 1990-91, this report examines trends affecting the future work of technicians in Quebec, their pre-employment education, and the link between college and work. Part 1 focuses on aspects of the economic, technological, and social environment that will influence the future role of technicians. Economic concerns…

  4. Electric Motor Systems Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 3006.2

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2006

    2006-01-01

    The graduate of the Electric Motor Systems Technician apprenticeship program is a certified journeyperson who will be able to: (1) understand the principles of sound and safe trade practices; (2) interpret drawings, plans, and be able to layout and develop projects according to specifications; (3) use the tools of the trade in a safe and proper…

  5. Changes in the ocular surface: initial observations from a pilot study of diagnostic radiology technicians (radiographers)

    International Nuclear Information System (INIS)

    Guerdal, Canan; Aydin, Sevda; Sengoer, Tomris; Onmus, Hale; Oezarar, Muemtaz

    2002-01-01

    The purpose of this study was to evaluate the clinical and cytological changes in the ocular surface of radiology technicians (radiographers) exposed to diagnostic doses of radiation. The Schirmer, Rose Bengal staining and Tear-Break-Up-Time tear function tests were carried out following routine ophthalmic examination in 15 radiology technicians (group I) and 15 controls (group II). Impression cytology was performed by placing 5-mm-thick half-circular cellulose acetate filter paper in the upper and lower quadrants around the limbus. The cytological evaluation was made using the mapping technique. Significantly increased dry eye was detected in group I. In the impression cytology investigation, squamous metaplasia and intraepithelial lymphocytic infiltration was noted in all the group-I cases. A distinct change was observed between the regions showing squamous metaplasia and neigbouring normal epithelial cell structure. Dry eye and ocular surface cytological changes were observed in diagnostic radiology technicians. Routine ophthalmic evaluation of radiology technicians would be beneficial in detecting early cytological changes and dry eye. (orig.)

  6. Prioritising Progression over Proficiency: Limitations of Teacher-Based Assessment within Technician-Level Vocational Education

    Science.gov (United States)

    Carter, Alan; Bathmaker, Ann-Marie

    2017-01-01

    This article examines the evolution of assessment policy and practice in technician-level vocational education. Using the example of an advanced-level BTEC National programme in Engineering in one college in the UK, the article highlights how the origins of current assessment practice lie in genuine concerns since the late 1950s about the…

  7. [Position-checking by imaging embarked there tomotherapy and the delegation to the radiology technician].

    Science.gov (United States)

    Autret, A; Choupeaux, D; Le Mée, M

    2016-10-01

    Tomotherapy is a technique of IMRT and IGRT using a linear accelerator and a helical CT-scanner. To reach this targeting of precision, the repositioning of the patient is essential. The use of a contention adapted according to the location of the disease and the morphology of the patient is necessary for the safety of this one and the treatment. Once the patient positioned on the reference table, technicians of imager's team check by the acquisition of helical imagery with the reference CT-scanner the position of the patient, the zone of the PTV and healthy organs in the protected surroundings. At first, adjustment will be made automatically on three planes of the space (axial, sagittal, frontal) and three rotations (pitch, roll and yaw) by the device of treatment, then the technicians of imagery will bring a modification of these recalls manually. After validation, the processing will then be made in complete safety for the patient and the nursing. This check by MVCT is daily before every session of processing. It is made by the technicians of imagery. The radiation oncologist confirms the images at j0, then controls once a week MVCT. Traceability in the file of the patient of the various marks (osseous and\\or soft tissue) necessary for the daily gaps will be noted by this one to delegate to the technicians of imagery the validation of the MVCT before every session. Copyright © 2016. Published by Elsevier SAS.

  8. A global picture of pharmacy technician and other pharmacy support workforce cadres

    NARCIS (Netherlands)

    Koehler, Tamara; Brown, A.

    a b s t r a c t Introduction: Understanding how pharmacy technicians and other pharmacy support workforce cadres assist pharmacists in the healthcare system will facilitate developing health systems with the ability to achieve universal health coverage as it is defined in different country contexts.

  9. How Technicians Can Lead Science Improvements in Any School: A Small-Scale Study in England

    Science.gov (United States)

    Jones, Beth; Quinnell, Simon

    2015-01-01

    This article describes how seven schools in England improved their science provision by focusing on the professional development of their science technicians. In September 2013, the Gatsby Charitable Foundation funded the National Science Learning Centre to lead a project connecting secondary schools with experienced senior science technicians…

  10. Automotive Service Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 0912

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Automotive Service Technician apprenticeship program is a certified journeyperson who will be able to: (1) repair, maintain and overhaul or modify a motor vehicle; (2) comprehend work orders, technical bulletins and estimates, and relate the information to the job at hand; (3) interpret warranty policy in terms of service…

  11. Rig Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5211.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Rig Technician apprenticeship program is a certified journeyperson who will be able to: (1) take responsibility for personal safety and the safety of others; (2) supervise, coach and train apprentices and floor hands; (3) perform the duties of a motorhand, derrickhand or driller; and (4) perform assigned tasks in accordance…

  12. Large Outbreak of Hepatitis C Virus Associated With Drug Diversion by a Healthcare Technician.

    Science.gov (United States)

    Alroy-Preis, Sharon; Daly, Elizabeth R; Adamski, Christine; Dionne-Odom, Jodie; Talbot, Elizabeth A; Gao, Fengxiang; Cavallo, Steffany J; Hansen, Katrina; Mahoney, Jennifer C; Metcalf, Erin; Loring, Carol; Bean, Christine; Drobeniuc, Jan; Xia, Guo-Liang; Kamili, Saleem; Montero, José T

    2018-05-14

    In May 2012, the New Hampshire (NH) Division of Public Health Services (DPHS) was notified of 4 persons with newly diagnosed hepatitis C virus (HCV) infection at hospital X. Initial investigation suggested a common link to the hospital cardiac catheterization laboratory (CCL) because the infected persons included 3 CCL patients and a CCL technician. NH DPHS initiated an investigation to determine the source and control the outbreak. NH DPHS conducted site visits, case patient and employee interviews, medical record and medication use review, and employee and patient HCV testing using enzyme immunoassay for anti-HCV, reverse-transcription polymerase chain reaction for HCV RNA, nonstructural 5B (NS5B) and hypervariable region 1 (HVR1) sequencing, and quasispecies analysis. HCV HVR1 analysis of the first 4 cases confirmed a common source of infection. HCV testing identified 32 of 1074 CCL patients infected with the outbreak strain, including 3 patients coinfected with >1 HCV strain. The epidemiologic investigation revealed evidence of drug diversion by the HCV-infected technician, evidenced by gaps in controlled medication control, higher fentanyl use during procedures for confirmed cases, and building card key access records documenting the presence of the technician during days when transmission occurred. The employee's status as a traveling technician led to a multistate investigation, which identified additional cases at prior employment sites. This is the largest laboratory-confirmed drug diversion-associated HCV outbreak published to date. Recommendations to reduce drug diversion risk and to conduct outbreak investigations are provided.

  13. Medical Laboratory Technician--Hematology, Serology, Blood Banking, and Immunohematology (AFSC 90470).

    Science.gov (United States)

    Thompson, Joselyn H.

    This three-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for medical laboratory technicians. Covered in the individual volumes are hematology (the physiology of blood, complete blood counts and related studies, erythrocyte studies, leukocyte and thrombocyte maturation, and blood…

  14. Medical Laboratory Technician--Microbiology, 10-3. Military Curriculum Materials for Vocational and Technical Education.

    Science.gov (United States)

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This course, the second of three courses in the medical laboratory technician field adapted from military curriculum materials for use in vocational and technical education, was designed as a refresher course for student self-study and evaluation. It is suitable for use by advanced students or beginning students participating in a supervised…

  15. V-TECS Guide for Automobile Air Conditioning and Electrical System Technician.

    Science.gov (United States)

    Meyer, Calvin F.; Benson, Robert T.

    This curriculum guide provides an outline for an eight-unit course to train automobile air conditioning and electrical system technicians. Each unit focuses on a duty that is composed of a number of performance objectives. For each objective, these materials are provided: a task, a standard of performance of task, source of standard, conditions…

  16. An Analysis of the Future Need for Certified Animal Health Technicians and Instructional Program Content.

    Science.gov (United States)

    Nevada State Council on Occupational Education, Carson City.

    A study examined the future need for certified animal health technicians (CAHT) in Nevada and the skills/knowledge that future CAHTs will need. Questionnaires were mailed to all of Nevada's 306 licensed veterinarians; 100 (32.68%) responded. The estimated numbers of CAHTs needed by the state's veterinarians in 1, 3, and 5 years were 62, 142, and…

  17. Animal Health Technicians: A Survey of Program Graduates and of Veterinarians.

    Science.gov (United States)

    Barsaleau, Richard B.; Walters, Henry R.

    This document compiles the reports of two surveys conducted by Cosumnes River College to determine the status of graduates of its Animal Health Technician program, and to assess the acceptance and use of such paraprofessionals by area veterinarians. Information concerning type of employment, state certification, salaries, types of duties, length…

  18. Requirements for, and training and certification of, quality assurance technicians for nuclear power plants

    International Nuclear Information System (INIS)

    Saiz, A.; Mir, A.; Serrano, J.

    1982-01-01

    The paper examines the requirements for, and training and certification of, technicians working in a quality assurance department at periods when the site, the main supplier and the engineering firm are being selected for construction, commissioning and operation of a light-water nuclear power plant with an output of approximately 1000 MW(e). In determining the system to be applied for the present work, account is taken of the special fields of engineering, supply, commissioning and operation. To this end, an analysis is made of the necessary organization, pointing out the number of technicians in each of the phases mentioned, and the necessary experience and knowledge required for discharging the functions indicated and for obtaining the appropriate certification. The second generation of Spanish nuclear power stations - about 7500MW(e) - demonstrated the need for quality assurance technicians. The Spanish Atomic Forum, a member of Foratom, is the first Spanish body to deal with the problem of training of such technicians at the national level through holding of seminars. This led to the appearance (in April 1974) of the first publication in Spanish on these techniques, a document which is still being used for teaching purposes. Later, it was the university and the professional associations which, with the support of the State Administration, undertook to provide this instruction. The paper also analyses Spanish experience in the teaching of quality assurance techniques during the period 1975-80, describing the programmes and contents of the courses

  19. The Hazardous Material Technician Apprenticeship Program at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Steiner, S.D.

    1987-07-01

    This document describes an apprenticeship training program for hazardous material technician. This entry-level category is achieved after approximately 216 hours of classroom and on-the-job training. Procedures for evaluating performance include in-class testing, use of on-the-job checks, and the assignment of an apprentice mentor for each trainee

  20. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 3--Anatomy and Physiology. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the third in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains one section covering the following topics: general anatomical terms, the body cavities and contents, the integumentary system, the skeletal system, the muscular system, the nervous system, the respiratory…

  1. Fuzzy hybrid MCDM approach for selection of wind turbine service technicians

    Directory of Open Access Journals (Sweden)

    Goutam Kumar Bose

    2016-01-01

    Full Text Available This research paper is aimed to present a fuzzy Hybrid Multi-criteria decision making (MCDM methodology for selecting employees. The present study aspires to present the hybrid approach of Fuzzy multiple MCDM techniques with tactical viewpoint to support the recruitment process of wind turbine service technicians. The methodology is based on the application of Fuzzy ARAS (Additive Ratio Assessment and Fuzzy MOORA (Multi-Objective Optimization on basis of Ratio Analysis which are integrated through group decision making (GDM method in the model for selection of wind turbine service technicians’ ranking. Here a group of experts from different fields of expertise are engaged to finalize the decision. Series of tests are conducted regarding physical fitness, technical written test, practical test along with general interview and medical examination to facilitate the final selection using the above techniques. In contrast to single decision making approaches, the proposed group decision making model efficiently supports the wind turbine service technicians ranking process. The effectiveness of the proposed approach manifest from the case study of service technicians required for the maintenance department of wind power plant using Fuzzy ARAS and Fuzzy MOORA. This set of potential technicians is evaluated based on five main criteria.

  2. A WIDER ROLE FOR TECHNICIANS IN SCIENCE PRACTICAL WORK WITH SCHOOL STUDENTS?

    Directory of Open Access Journals (Sweden)

    Timothy G. Harrison

    2011-12-01

    Full Text Available This paper reports the results of a study made on the impact of improved deployment of science technicians in the classroom could directly benefit students in practical science investigations. Science technicians are skilled individuals whose understanding of practical work is a valuable resource not being used of in support of students understanding of science. Aspects of practical work and technician support were scrutinised, through information attained from a post-16 student survey to improve understanding about this teaching tool, to establish if it was being used to its full potential within science lessons. Analysis was also made of students’ perceptions of school science. The main outcomes were that the majority of students enjoyed science practical work and felt that science could not be taught without it. Students studying science at pre-university level attained a greater understanding, through participating in relevant practical work, than students who had studied it at earlier, compulsory levels. Students reported that science technicians provide impact on student learning when contact time was the greatest.

  3. A Canadian Approach to Training Technicians and Technologists In the Earth Sciences.

    Science.gov (United States)

    Watts, Stephen H.

    1983-01-01

    Describes two- and three-year undergraduate curricula for training earth science technicians at Sir Sanford Fleming College (Canada), emphasizing practical aspects and close student-faculty interaction. List of employment opportunities for geology graduates based on past placement data and geology curriculum outline are provided in tables. (JN)

  4. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  5. Accuracy of vision technicians in screening ocular pathology at rural vision centres of southern India.

    Science.gov (United States)

    Suram, Vasantha; Addepalli, Uday Kumar; Krishnaiah, Sannapaneni; Kovai, Vilas; Khanna, Rohit C

    2016-03-01

    There is paucity of data on the inter-observer agreement and diagnostic accuracy between a primary-care technician (vision technician) and an ophthalmologist. Hence, the current study was conducted to assess the accuracy of vision technicians, to screen potentially sight-threatening ocular conditions at rural vision centres of southern India and their agreement with an ophthalmologist. In July to August 2010, patients presenting to seven vision centres in Adilabad district (Andhra Pradesh) were selected and screened in a masked manner by seven vision technicians followed by an examination by a consultant ophthalmologist. Agreement was assessed between vision technicians and the ophthalmologist for screening of potential sight-threatening ocular conditions and decisions for referral. The ophthalmologist's findings were considered as the reference standard. Two hundred and seventy-nine patients were enrolled at seven vision centres with a mean age of 32.9 ± 21.8 years. Agreement for screening of ocular pathology was 0.82 (95 per cent CI, 0.8-0.83). There was excellent agreement for cataract (0.97; 95 per cent CI, 0.93-1), refractive error (0.98; 95 per cent CI, 0.96-1), corneal pathology (1.0; 95 per cent CI, 1.0-1.0) and other anterior segment pathology (0.95; 95 per cent CI, 0.9-1); the agreement was moderate to fair for detection of glaucoma suspects (0.43; 95 per cent CI, 0.28-0.60) and retinal pathology (0.39; 95 per cent CI, 0.14-0.63). Sensitivity for screening of anterior segment pathology was 94.6-100 per cent. There was a fair to moderate sensitivity for glaucoma suspect; 35.6 per cent (95 per cent CI, 21.9-51.2) and retinal pathology 26.3 per cent (95 per cent CI, 9.2-51.2). Specificity for screening of ocular pathology was 98.2 to 100 per cent. The kappa (κ) agreement for referral for any pathology was 0.82 (0.8-0.83) CONCLUSION: As there is good agreement between the vision technicians and the ophthalmologist for screening and referral of

  6. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  7. Effect of dental technician disparities on the 3-dimensional accuracy of definitive casts.

    Science.gov (United States)

    Emir, Faruk; Piskin, Bulent; Sipahi, Cumhur

    2017-03-01

    Studies that evaluated the effect of dental technician disparities on the accuracy of presectioned and postsectioned definitive casts are lacking. The purpose of this in vitro study was to evaluate the accuracy of presectioned and postsectioned definitive casts fabricated by different dental technicians by using a 3-dimensional computer-aided measurement method. An arch-shaped metal master model consisting of 5 abutments resembling prepared mandibular incisors, canines, and first molars and with a 6-degree total angle of convergence was designed and fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Complete arch impressions were made (N=110) from the master model, using polyvinyl siloxane (PVS) and delivered to 11 dental technicians. Each technician fabricated 10 definitive casts with dental stone, and the obtained casts were numbered. All casts were sectioned, and removable dies were obtained. The master model and the presectioned and postsectioned definitive casts were digitized with an extraoral scanner, and the virtual master model and virtual presectioned and postsectioned definitive casts were obtained. All definitive casts were compared with the master model by using computer-aided measurements, and the 3-dimensional accuracy of the definitive casts was determined with best fit alignment and represented in color-coded maps. Differences were analyzed using univariate analyses of variance, and the Tukey honest significant differences post hoc tests were used for multiple comparisons (α=.05). The accuracy of presectioned and postsectioned definitive casts was significantly affected by dental technician disparities (Ptechnician differences. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Experimental equipment, ch. 6

    International Nuclear Information System (INIS)

    Boomstra, F.; Hoogenboom, A.M.; Prins, C.M.; Strasters, B.A.; Vermeer, A.; Wit, P. de; Zwol, N.A. van.

    1977-01-01

    The experimental equipment in use at Utrecht university is discussed. Attention is paid to the tandem Van de Graaff accelerator and the 4MV and 1MV accelerators. The detection systems for gamma-ray spectroscopy are reviewed with emphasis on the compton-suppression spectrometer. The data-handling system used for experiments with the tandem is also briefly discussed

  9. Equipment gift to Monaco

    International Nuclear Information System (INIS)

    1970-01-01

    Research work at the Agency's Laboratory of Marine Radioactivity in Monaco, including that concerned with pollution of the sea, has been made more effective by its latest acquisition of equipment. This is a spectrophotometer donated by the Federal Republic of Germany. (author)

  10. Safeguards techniques and equipment

    International Nuclear Information System (INIS)

    1997-01-01

    The current booklet is intended to give a full and balanced description of the techniques and equipment used for both nuclear material accountancy and containment and surveillance measures, and for the new safeguards measure of environmental sampling. As new verification measures continue to be developed, the material in the booklet will be periodically reviewed and updated versions issued. (author)

  11. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  12. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  13. Orphee reactor experimental equipment

    International Nuclear Information System (INIS)

    1987-01-01

    Experimental equipment around the ORPHEE reactor is presented. The neutron source; and the spectrometers and sample environment (inelastic and quasi-elastic scattering, elastic scattering, spread scattering, small angle scattering) are described. An experiment proposal and reports guide is supplied [fr

  14. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  15. Purex: process and equipment performance

    International Nuclear Information System (INIS)

    Orth, D.A.

    1986-01-01

    The Purex process is the solvent extraction system that uses tributyl phosphate as the extractant for separating uranium and plutonium from irradiated reactor fuels. Since the first flowsheet was proposed at Oak Ridge National Laboratory in 1950, the process has endured for over 30 years with only minor modifications. The spread of the technology was rapid, and worldwide use or research on Purex-type processes was reported by the time of the 1955 Geneva Conference. The overall performance of the process has been so good that there are no serious contenders for replacing it soon. This paper presents: process description; equipment performance (mixer-settlers, pulse columns, rapid contactors); fission product decontamination; solvent effects (solvent degradation products); and partitioning of uranium and plutonium

  16. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2000-01-01

    Full text: The main objective of the activity of the Establishment for Nuclear Equipment (ZdAJ) in 1999 was to obtain the ISO 9001 certificate. Work on this problem has been successfully completed. The changes introduced in agreement with requirements of ISO in supervising the construction, manufacturing and servicing eliminate possible deficiencies of our products and will pay in the future. Two new important ventures have been undertaken: design of an accelerator with two photon energies and a reconstruction of simulator directed towards better geometrical parameters. The completion of the improvements in accelerator is foreseen for the year 2002. The changes comprise almost all sub-assemblies of the device. The modernized simulator will be installed in the hospital already in the year 2000 - the ameliorations concern mainly the arm of the apparatus, collimator, driving gears and control system. Of course - apart from this, the routine production activity of the Establishment was continued in 1999. (author)

  17. Doctors or technicians: assessing quality of medical education.

    Science.gov (United States)

    Hasan, Tayyab

    2010-01-01

    Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products.

  18. Doctors or technicians: assessing quality of medical education

    Directory of Open Access Journals (Sweden)

    Tayyab Hasan

    2010-09-01

    Full Text Available Tayyab HasanPAPRSB Institute of Health Sciences, University Brunei Darussalam, Bandar Seri Begawan, BruneiAbstract: Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products.Keywords: educational quality, medical education, quality control, quality assessment, quality management models

  19. Establishment for Nuclear Equipment -Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2006-01-01

    Research and development works conducted in the Establishment for Nuclear Equipment (ZdAJ) were focused around 3 subject areas: an accelerator for cancer treatment, therapeutical tables, systems and methods for controlling objects that cross international borders. The new, medium energy accelerator for cancer therapy cases is being designed in the Establishment for several years. In 2005 progress was achieved. A physical part, containing an electron beam has been completed and the parameters of that beam make it useful for therapeutical purposes. Consequently, the work on designing and testing of beam control systems, ensuring its high stability, repetition of irradiation parameters and accuracy of dosage have been started. Results of these tests make it very probable that 2006 will be the final year of scientific works and in 2007 the new apparatus will be ready for sales. Therapeutical tables have become a leading product of ZdAJ IPJ. Their technical parameters, reliability and universality in uses are appreciated by many customers of ZdAJ. In 2005, the table Polkam 16 was registered by the national Office for Registration of Medical Equipment as the first product of ZdAJ that meets all technical and formal requirements of the safety mark CE. This allows sales of the product on the market of the European Union. The research and development part of designing a therapeutical table for uses in the total body irradiation technique was also concluded in 2005. After the September 11 terrorist attacks on WTC a matter of controlling international borders have become a priority for many countries. In 2005 in ZdAJ IPJ, we conducted many preliminary calculations and experiments analyzing systems of irradiation sources, both photon and neutron as well as systems of detection and designing of signals triggered by controlling objects crossing the border. The results so far have enabled us to formulate a research project which has been positively evaluated by experts and found

  20. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  1. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  2. [Medical equipment product lines in basic pharmacies].

    Science.gov (United States)

    Macesková, B; Lipská, J

    2003-07-01

    Medical appliances dispensed in basic type pharmacies for cash or vouchers for medical or orthopedic appliances require expertise of pharmacists and laboratory assistants concerning the assortment, payment, construction of prices, conditions for prescription, ordering, properties, and functions of individual appliances. Using the method of frequency analysis, the analysis of data from five pharmacies within a period of three months (more than 17,000 records) revealed how individual subgroups of medical appliances and their concrete items are represented in both types of dispensation. The method of the semistructured questionnaire (10 respondents) was used to find what problems are encountered in dispensation, and which medical appliances and their subgroups are the sources of the problems. The respondents regard the contemporary level of knowledge concerning medical appliances gained in pregradual studies as insufficient.

  3. Equipment for linking source stand and film holder carriage

    International Nuclear Information System (INIS)

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  4. Internet treatment for generalized anxiety disorder: a randomized controlled trial comparing clinician vs. technician assistance.

    Science.gov (United States)

    Robinson, Emma; Titov, Nickolai; Andrews, Gavin; McIntyre, Karen; Schwencke, Genevieve; Solley, Karen

    2010-06-03

    Internet-based cognitive behavioural therapy (iCBT) for generalized anxiety disorder (GAD) has been shown to be effective when guided by a clinician. The present study sought to replicate this finding, and determine whether support from a technician is as effective as guidance from a clinician. Randomized controlled non-inferiority trial comparing three groups: Clinician-assisted vs. technician-assisted vs. delayed treatment. Community-based volunteers applied to the VirtualClinic (www.virtualclinic.org.au) research program and 150 participants with GAD were randomized. Participants in the clinician- and technician-assisted groups received access to an iCBT program for GAD comprising six online lessons, weekly homework assignments, and weekly supportive contact over a treatment period of 10 weeks. Participants in the clinician-assisted group also received access to a moderated online discussion forum. The main outcome measures were the Penn State Worry Questionnaire (PSWQ) and the Generalized Anxiety Disorder-7 Item (GAD-7). Completion rates were high, and both treatment groups reduced scores on the PSWQ (ptechnician-assisted groups, respectively, and on the GAD-7 were 1.55 and 1.73, respectively. At 3 month follow-up participants in both treatment groups had sustained the gains made at post-treatment. Participants in the clinician-assisted group had made further gains on the PSWQ. Approximately 81 minutes of clinician time and 75 minutes of technician time were required per participant during the 10 week treatment program. Both clinician- and technician-assisted treatment resulted in large effect sizes and clinically significant improvements comparable to those associated with face-to-face treatment, while a delayed treatment/control group did not improve. These results provide support for large scale trials to determine the clinical effectiveness and acceptability of technician-assisted iCBT programs for GAD. This form of treatment has potential to increase the

  5. Equipment cost optimization

    International Nuclear Information System (INIS)

    Ribeiro, E.M.; Farias, M.A.; Dreyer, S.R.B.

    1995-01-01

    Considering the importance of the cost of material and equipment in the overall cost profile of an oil company, which in the case of Petrobras, represents approximately 23% of the total operational cost or 10% of the sales, an organization for the optimization of such costs has been established within Petrobras. Programs are developed aiming at: optimization of life-cycle cost of material and equipment; optimization of industrial processes costs through material development. This paper describes the methodology used in the management of the development programs and presents some examples of concluded and ongoing programs, which are conducted in permanent cooperation with suppliers, technical laboratories and research institutions and have been showing relevant results

  6. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  7. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  8. Tube for irradiation equipment

    International Nuclear Information System (INIS)

    Goehrich, K.; Vogt, H.

    1979-01-01

    This patent describes a tube for irradiation equipment for limiting an emergent beam, with a baseplate, possessing a central aperture, intended for attaching to the equipment, as well as four carrier plates, each of which possesses a limiting edge and a sliding edge located at right angles thereto. The carrier plates are located parallel to the baseplate, the limiting edge of each carrier plate resting against the sliding edge of the adjacent carrier plate and each of the two mutually opposite pairs of carrier plates being displaceable, parallel to the direction of its sliding edges and symmetrically to the center of the transmission aperture, for the purpose of continuously varying the transmission aperture defined by the limiting edges, during which displacement each of the displaced carrier plates carries with it the carrier plate, resting against the limiting edge of the former plate, parallel to the direction of the limiting edge of the latter plate. 8 claims

  9. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  10. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  11. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  12. Performance Measurement of Mining Equipments by Utilizing OEE

    Directory of Open Access Journals (Sweden)

    Sermin Elevli

    2010-10-01

    Full Text Available Over the past century, open pit mines have steadily increased their production rate by using larger equipments which requireintensive capital investment. Low commodity prices have forced companies to decrease their unit cost by improving productivity. Oneway to improve productivity is to utilize equipment as effectively as possible. Therefore, the accurate estimation of equipmenteffectiveness is very important so that it can be increased. Overall Equipment Effectiveness (OEE is a well-known measurementmethod, which combines availability, performance and quality, for the evaluation of equipment effectiveness in manufacturing industry.However, there isn’t any study in literature about how to use this metric for mining equipments such as shovel, truck, drilling machineetc. This paper will discuss the application of OEE to measure effectiveness of mining equipment. It identifies causes of time losses forshovel and truck operations and introduces procedure to record time losses. The procedure to estimate OEE of shovels and trucks hasalso been presented via numerical example.

  13. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  14. The enforcement order for the law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1984-01-01

    The enforcement order provides for the medical radiation technicians and medical X-ray technicians according to the established for them. The applicants for the license thereof must present their applications, together with the necessary documents, to the Government (or the prefectural government). The contents are as follows: application for license; to be entered in the register (with the items of the license); alteration of the registered items (the immediate corrective action, to the Government); elimination of the technicians from the register (to the Government); alteration of the license (the corrective action, to the Government); application for reissue of the license (to the Government); notification concerning the administrative measures. (Mori, K.)

  15. Pedagogical Strategy for the professional training of technicians in Accountability and Auditing

    Directory of Open Access Journals (Sweden)

    Martha Ximena Jaramillo-Lema

    2016-06-01

    Full Text Available The professionals in the specialty of Accounting and Auditing have an important role in the founding of mid and small enterprises (PYMES, therefore, there is need of forming technicians of high quality. However, after the application of different methods of research, it has been proven that there are insufficiencies in their work, which has brought about that the hirers reject to employ them. They support their decision saying that these technicians lack professional preparation in the processes of accounting and auditing. The present article has as main purpose, to propose a pedagogical strategy for the development of updating and upbringing courses based on the development in the spheres of accounting and auditing , thus it has been designed a system of actions of marked pedagogical effect that allows the achievement of this objective.

  16. Respiratory assessment of refractory ceramic fibers in a heating technician population.

    Science.gov (United States)

    Lucas, David; Clamagirand, Vincent; Capellmann, Pascale; Hervé, Agnès; Mauguen, Gilles; Le Mer, Yannik; Jegaden, Dominique

    2018-04-01

    Refractory ceramic fibers (RCF) have been extensively used for insulation in condensing boilers. The aim of this study was to evaluate the respiratory exposure to these fibers among maintenance heating technicians. We first created a working group (Carsat Brittany and Finistère Occupational Health Services) and carried out a sampling strategy. Atmospheric measurements were done during work tasks, and filters were analyzed by phase contrast microscopy (PCM) and scanning electron microscopy (SEM) in French approved laboratories. Four companies were included for a total of 15 days of work. During those 15 workdays, 12 SEM and 21 PCM samples were taken and analyzed. The phase contrast microscopy and SEM average results were 0.04 and 0.004 fibers/cm 3 , respectively. In conclusion, the study confirms heating technician RCF respiratory exposure during maintenance work for both condensation gas boilers and atmospheric boilers. Collective and individual prevention measures should be implemented along with appropriate medical follow-up.

  17. Child Passenger Safety Technician Consultation in the Pediatric Primary Care Setting.

    Science.gov (United States)

    Burstein, Dina; Zonfrillo, Mark R; Baird, Janette; Mello, Michael J

    2017-09-01

    Correct use of a child safety seat (CSS) can reduce the risk of fatal motor vehicle crash-related injury by up to 71%; however, misuse rates for CSS are as high as 70%. We recruited 189 caregivers at 2 large suburban pediatric office practices; 94 in the intervention group and 95 in the control group. All participants completed a baseline survey and received a CSS safety brochure. Intervention participants had their CSS installation checked at enrollment by a certified child passenger safety (CPS) technician. Follow-up was conducted 4 months post enrollment. Intervention group participants had a 21.3% reduction in critical misuse at follow-up, whereas control participants critical misuse rate at follow-up was identical to the intervention group at baseline. A consult with a certified CPS technician, at the time of a routine visit to the pediatrician, resulted in a reduction in CSS misuse rates.

  18. Strategies used by nursing technicians to face the occupational suffering in an emergency unit

    Directory of Open Access Journals (Sweden)

    Alessandra Bassalobre Garcia

    2016-05-01

    Full Text Available Objective: to understand the strategies used by nursing technicians in order to face the occupational suffering in an emergency room. Methods: qualitative study carried out in an emergency room of a high complexity hospital located in the north of Paraná state. Data were collected through semi-structured interviews with 12 nursing technicians. The analysis relied on content analysis procedures. Results: respondents revealed as individual strategies to face suffering: try not to get involved with the patient; separation between professional and personal life; and spirituality/religion as support for coping. The collective strategies described by respondents included: action planning for unexpected events in this unit; creating a supportive environment; and attempt to obtain recognition of headship. Conclusion: individual and collective strategies were used consciously by workers and should be encouraged by managers to face the occupational suffering.

  19. Time to pregnancy among Danish laboratory technicians who were a part of the National Birth Cohort

    DEFF Research Database (Denmark)

    Zhu, Jin Liang; Knudsen, Lisbeth E; Andersen, Anne-Marie Nybo

    2005-01-01

    OBJECTIVES: The Danish National Birth Cohort was used to examine whether laboratory work was associated with reduced fecundity. METHODS: Self-reported data on laboratory work and waiting time to pregnancy (0-2, 3-5, 6-12 and > 12 months) were used for 829 female laboratory technicians interviewed...... in 1997-2003. Altogether 6250 female teachers formed the reference group. A discrete-time survival analysis with a complementary log-log link was applied to estimate the fecundability ratio between the exposed and unexposed women, with adjustment for maternal age, gravidity, smoking, prepregnancy body......) 0.86-1.02] for all pregnancies and 0.98 (95% CI 0.86-1.13) for first pregnancies. A healthy worker effect was found for the laboratory technicians working with the work processes under study. CONCLUSIONS: The results do not suggest that laboratory work in Denmark at present impairs female fecundity....

  20. Integrating Safety in the Aviation System: Interdepartmental Training for Pilots and Maintenance Technicians

    Science.gov (United States)

    Mattson, Marifran; Petrin, Donald A.; Young, John P.

    2001-01-01

    The study of human factors has had a decisive impact on the aviation industry. However, the entire aviation system often is not considered in researching, training, and evaluating human factors issues especially with regard to safety. In both conceptual and practical terms, we argue for the proactive management of human error from both an individual and organizational systems perspective. The results of a multidisciplinary research project incorporating survey data from professional pilots and maintenance technicians and an exploratory study integrating students from relevant disciplines are reported. Survey findings suggest that latent safety errors may occur during the maintenance discrepancy reporting process because pilots and maintenance technicians do not effectively interact with one another. The importance of interdepartmental or cross-disciplinary training for decreasing these errors and increasing safety is discussed as a primary implication.