WorldWideScience

Sample records for procedure involves removal

  1. Comparison of hand hygiene procedures for removing Bacillus cereus spores.

    Science.gov (United States)

    Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu

    2014-01-01

    Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.

  2. Operability test procedure [Tank] 241-SY-101 equipment removal system

    International Nuclear Information System (INIS)

    Mast, J.C.

    1994-01-01

    The 241-SY-101 equipment removal system (ERS) consists of components, equipment, instrumentation and procedures that will provide the means to disconnect, retrieve, contain, load and transport the Mitigation Pump Assembly (MPA) from waste Tank 241-SY-101 to the Central Waste Complex (CWC). The Operability Test Procedure (OTP) will test the interfaces between ERS components and will rehearse the procedure for MPA removal and transportation to the extent they can be mocked-up at the CTF (Cold Test Facility). At the conclusion of the OTP, the ERS components and equipment will be removed from the CTF, entered into the Component Based Recall System (CBRS), and stored until needed for actual MPA removal and transportation

  3. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners.

    Science.gov (United States)

    Fokkinga, Wietske A; van Uchelen, Judith; Witter, Dick J; Mulder, Jan; Creugers, Nico H J

    2016-01-01

    This pilot study analyzed impression procedures for conventional metal frame removable partial dentures (RPDs). Heads of RPD departments of three dental laboratories were asked to record features of all incoming impressions for RPDs during a 2-month period. Records included: (1) impression procedure, tray type (stock/custom), impression material (elastomer/alginate), use of border-molding material (yes/no); and (2) RPD type requested (distal-extension/tooth-bounded/combination). Of the 132 total RPD impressions, 111 (84%) involved custom trays, of which 73 (55%) were combined with an elastomer. Impression border-molding material was used in 4% of the cases. Associations between impression procedure and RPD type or dentists' year/university of graduation were not found.

  4. Procedural Sedation for the removal of a rectal foreign body

    Directory of Open Access Journals (Sweden)

    John Costumbrado, MD, MPH

    2018-04-01

    Full Text Available History of present illness: A 40-year-old male with a history of intravenous drug use presented to the emergency department (ED for one week of constant lower abdominal pain associated with bloody stool. He denied fever, nausea, vomiting, urinary symptoms, and testicular pain or swelling. On exam, vital signs were within normal limits. Abdominal exam was non-tender without rebound or guarding. Rectal exam was negative for occult blood but positive for a palpable firm, blunt object. A computed tomography (CT of the abdomen and pelvis was ordered to further investigate. Significant findings: Axial and coronal views on CT showed evidence of a large, tube-shaped foreign body in the rectum (see arrows without evidence of acute gastrointestinal tract disease. Discussion: While rectal foreign bodies (RFB are not uncommon to the ED, accurate epidemiological estimates are not available, due in part to underreporting.1 One study estimated an incidence of one patient per month that needed care for a RFB.2 Generally, patients can remove the object themselves; however, 20% of cases require endoscopic intervention and 1% require surgical intervention.3 RFBs can be removed via the transanal approach manually, instrument-assisted (eg, Kocher clamp, obstetric forceps, or endoscopically. In cases without intestinal perforation, transanal removal of a RFB is generally attempted as a first-line procedure in the ED, with an approximate success rate of 75%.4 However, the limitations of transanal removal depends on the location of the object, level of anal relaxation, and ability to grasp the object, which may be limited by the provider’s hand size and availability of instruments.Ways of facilitating bedside removal of RFBs include the Valsalva maneuver with proper positioning (i.e., lithotomy or prone knee-to-chest position or manual abdominal wall compression to help move the object closer to the anal orifice. Anoscopy may also be used to improve visualization of

  5. Comparative efficiency of final endodontic cleansing procedures in removing a radioactive albumin from root canal systems

    International Nuclear Information System (INIS)

    Cecic, P.A.; Peters, D.D.; Grower, M.F.

    1984-01-01

    Fifty-six teeth were initially instrumented, with the use of seven irrigants or irrigant combinations, and filled with radioactive albumin. The study then showed the relative ability of three final endodontic procedures (copious reirrigation with saline solution, drying with paper points, and reassuring patency of the canal with the final instrument) to remove the albumin. Even after copious irrigation, each additional procedure removed statistically significant amounts of albumin. Alternating an organic solvent and an inorganic solvent did appear to leave the canal system in the optimal condition for final cleansing procedures. The study then correlated the relative efficiency of irrigation alone versus instrumentation plus irrigation in removing the remaining albumin from the canal systems. Reinstrumentation plus copious irrigation removed significantly more albumin than copious irrigation alone

  6. Test procedures and instructions for Hanford tank waste supernatant cesium removal

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, D.W., Westinghouse Hanford

    1996-05-31

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test using Hanford Double-Shell Slurry Feed supernatant liquor from tank 251-AW-101 in a bench-scale column.Cesium sorbents to be tested include resorcinol-formaldehyde resin and crystalline silicotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-022, Hanford Tank Waste Supernatant Cesium Removal Test Plan.

  7. The removal of metals from edible oil by a membrane extraction procedure 355

    NARCIS (Netherlands)

    Keurentjes, J.T.F.; Bosklopper, T.G.J.; Dorp, van L.J.; Riet, van 't K.

    1990-01-01

    Edible oils may contain traces of metals. In oil refining procedures these metals have to be removed to guarantee oxidatively stable products. In this study we present a hollow fiber membrane extraction system for the removal of metals from an oil. Several extraction liquids were tested, of which an

  8. Procedure to remove a dirt and/or oil film from water

    Energy Technology Data Exchange (ETDEWEB)

    Jager, T; Jager, G P.A.; Jager, K L.E.

    1970-12-11

    A procedure is described to remove dirt and/or oil films from a water surface. A number of rotating wiper scoops moves through the water. The top of the polluted water is brought into motion by the scoops and directed to a gutter system where it is removed. The advantage of the system is that the wiper scoops can be lowered selectively to the depth of the pollutant, thereby avoiding moving large quantities of unnecessary unpolluted liquid which later has to be separated. (12 claims)

  9. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  10. Clinical study of treatment of cerebral hemorrhage: remove the intracranial hematoma with a minimal invasive procedure

    International Nuclear Information System (INIS)

    Ke Dongfeng; He Yunguang; Hu Wen; Lin Yang; Yang Danyang; Chen Shaokai; Ma Shaobing

    2004-01-01

    Objective: To study the feasibility and factors of minimal invasive intracranial hematoma removing procedure as a treatment of cerebral hemorrhage. Methods: From May, 2000 to September, 2003, 33 patients with intracerebral hemorrhage underwent minimal invasive intracranial hematoma removing procedure and from May, 1997 to September, 2000, 27 patients with cerebral hemorrhage received conservative treatments. Two groups were compared and analyzed. The quantity of hemorrhage and the indication of procedure were also studied. Results: State of an illness has no significant difference between the two groups (P<0.05). The rate of recovery were higher in the group undergoing the procedure (57.6%) than in the control group (14.8%) (P<0.05). The rate of handicap were lower in the procedure group (24.0%) than in the control group (60.0%) (P<0.05). The mortality were also lower in the procedure group (24.2%) than in the control group (63.0%) (P<0.01). In the control group no patient with a hematoma larger than 70 ml survived. In the procedure group patients with hematoma larger than 70 ml had less chance of survival than the other patients (P<0.01). The mortality rate were respectively 50%, 5.6%, 33.3% when the procedure was done in super early, early, delayed stage. The mortality rate was higher in the super early stage than in early stage (P<0.05). Conclusion: The minimal invasive intracranial hematoma removing procedure has a better clinical outcome than the conservative treatment. The procedure reduces obviously mortality rate and increase the quality of survival. Multiple puncturing and draining or craniotomy are recommended to remove huge hematoma. The earlier treatment brings better clinical effects. This technique is simple, less invasive and provides good clinical outcome, which is worth recommendation

  11. Specifically requesting surgical tattoo removal: are deep personal motivations involved?

    Science.gov (United States)

    Koljonen, V; Kluger, N

    2012-06-01

      Motivations for tattoo removal include employment reasons, stigmata, changes in lifestyles or partners, incompatibility with present attitudes and values and clothing problems. Most studies on the motivations for tattoo removal have focused on patients seeking laser therapy. We hypothesized that patients seeking surgical tattoo removal would present with different motivations.   We analysed the characteristics and motivations of patients specifically requesting surgical tattoo removal.   We retrospectively reviewed the medical records of 16 patients in Helsinki, Finland, from 2005 to 2011. Demographic, clinical data, number of tattoos, location and size, time elapsed since tattooing, reason(s) for wanting surgical tattoo removal and surgical operations were analysed and compared with the other literature on tattoo removal.   Patients were mainly Caucasian females (ratio 3 : 1, median age of 26 years). Tattoos were all done by studio artists, most measured less than 30 cm², and were quite recent (median 5.3 years). Personal reasons accounted for 42.8% of all reasons, professional/social reasons for 37.5% and miscellaneous for 18.8%. Personal concerns were usually marital status changes, with few expressing dissatisfaction with the actual design of the tattoo. Tattoos were excised during a single procedure in 70% of the cases with only one case producing a hypertrophic scar.   Patients seeking surgical removal were aware of the limits and risks of the technique. They expressed intense personal reasons for wanting radical surgical removal. The possibility of surgical tattoo removal should be accessible to patients if the tattoo is small and discussion reveals strong personal motivation. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  12. An Efficient Procedure for Removal and Inactivation of Alpha-Synuclein Assemblies from Laboratory Materials.

    Science.gov (United States)

    Bousset, Luc; Brundin, Patrik; Böckmann, Anja; Meier, Beat; Melki, Ronald

    2016-01-01

    Preformed α-synuclein fibrils seed the aggregation of soluble α-synuclein in cultured cells and in vivo. This, and other findings, has kindled the idea that α-synuclein fibrils possess prion-like properties. As α-synuclein fibrils should not be considered as innocuous, there is a need for decontamination and inactivation procedures for laboratory benches and non-disposable laboratory material. We assessed the effectiveness of different procedures designed to disassemble α-synuclein fibrils and reduce their infectivity. We examined different commercially available detergents to remove α-synuclein assemblies adsorbed on materials that are not disposable and that are most found in laboratories (e.g. plastic, glass, aluminum or stainless steel surfaces). We show that methods designed to decrease PrP prion infectivity neither effectively remove α-synuclein assemblies adsorbed to different materials commonly used in the laboratory nor disassemble the fibrillar form of the protein with efficiency. In contrast, both commercial detergents and SDS detached α-synuclein assemblies from contaminated surfaces and disassembled the fibrils. We describe three cleaning procedures that effectively remove and disassemble α-synuclein seeds. The methods rely on the use of detergents that are compatible with most non-disposable tools in a laboratory. The procedures are easy to implement and significantly decrease any potential risks associated to handling α-synuclein assemblies.

  13. 29 CFR 1904.9 - Recording criteria for cases involving medical removal under OSHA standards.

    Science.gov (United States)

    2010-07-01

    ... surveillance requirements of an OSHA standard, you must record the case on the OSHA 300 Log. (b) Implementation—(1) How do I classify medical removal cases on the OSHA 300 Log? You must enter each medical removal case on the OSHA 300 Log as either a case involving days away from work or a case involving restricted...

  14. Test procedures and instructions for Hanford complexant concentrate supernatant cesium removal using CST

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, D.W.

    1997-01-08

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Complexant Concentrate supernatant liquor from tank 241-AN-107, in a bench-scale column. The cesium sorbent to be tested is crystalline silicotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-023, Hanford Complexant Concentrate Supernatant Cesium Removal Test Plan.

  15. Procedures for Removal of Pesticides from the Environment

    Directory of Open Access Journals (Sweden)

    Đokić, M.

    2012-07-01

    Full Text Available Pesticides are widely used in food production, and it is believed that more than 1000 types of pesticides are in use. Organochlorines and organophosphorous pesticides are used in large quantities due to their efficacy and low cost. These persistent organic pollutants remain in the soil, silt, and sediment long after application, and enter into watercourses, finding their way directly into the food chain. Today, the following procedures are used to remove pesticides from polluted localities: low temperature thermal desorption, incineration, bioremediation and phytoremediation. Each of these technologies has its advantages and disadvantages. Ultimately, the ideal remediation process would be to completely destroy the pollutant without the production of byproducts. Some of these processes are only capable of moving and stabilizing the contaminant, but do not clean or fully eliminate the pollutant. Low temperature thermal desorption is an ex situ cleaning technology most often used to remove pesticides. The advantage of incineration is the complete elimination of the pollutant; however, this process is very expensive, as it requires transport of the media to the incinerator. The processes of bioremediation are stimulated by natural processes of microbiological degradation of contaminants through the interaction of microorganisms and nutrients from waste. Ex situ procedures include the use of bioreactors. Another procedure is land spreading, in which the contaminated medium is mixed with the soil, in which the native microorganisms degrade the pollutants. Efficacy in the biodegradation of toxic pollutants has been established for white root fungi, particularly those from the genus Phanerochaete. Phytoremediation is a green technology that uses plants, in which plants are not directly included in the process but serve as a catalyser for increasing the growth and activity of root microorga- nisms. In phytoremediation of pesticides, plants of the genus

  16. Computer aided planning of orthopaedic surgeries: the definition of generic planning steps for bone removal procedures.

    Science.gov (United States)

    Putzer, David; Moctezuma, Jose Luis; Nogler, Michael

    2017-11-01

    An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.

  17. Operational procedure standard for occurrences involving radioactive materials

    International Nuclear Information System (INIS)

    Piekarz, Leonardo; Rezende, Talita C.; Pinheiro, Christiano J.G.

    2017-01-01

    This study has as objective to analyze more deeply the actions of response to emergencies involving radioactive materials, in the intent to establish a pattern to the actions performed by the military fire fighters of the Military Fire Brigade of Minas Gerais. To met these goals, it has been attempted to analyze the procedures utilized and recommended, nowadays, for the military fire fighters of CBMMG, and through directed studies, to suggest new actions possible to be executed in the local of the emergency in a way that will not expose the garrison to doses of ionizing radiation that may prejudice them. It is a study of bibliographic, exploratory, and also descriptive nature, realized through a qualitative approach. The techniques used for the research were the analysis of institutional documents, norms and other literature produced by renamed entities in the radiologic and biosafety areas. It was then concluded that CBMMG, through simple actions of response, can provide higher quality and safety in the operations involving radiologic accidents, standing out that the implemented actions nowadays are very beneath the capacity of the corporation, due to the lack of knowledge of the matter by the fire fighters. It was proposed, then, that new actions be implemented and instituted as operational procedures to be used on those emergencies, with the objective of provide a higher safety and professionalism in the attendance to emergencies involving radioactive materials. (author)

  18. Operational procedure standard for occurrences involving radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Leonardo, E-mail: leonardopbm@yahoo.com.br [Academia de Bombeiros Militar de Minas Gerais, Belo Horizonte, MG (Brazil); Rezende, Talita C.; Pinheiro, Christiano J.G., E-mail: talitacolombi@yahoo.com, E-mail: christrieste@yahoo.it [Universidade Federal do Espirito Santo (CCA/UFES), Alegre, ES (Brazil). Programa de Pós-Graduação em Engenharia Química

    2017-07-01

    This study has as objective to analyze more deeply the actions of response to emergencies involving radioactive materials, in the intent to establish a pattern to the actions performed by the military fire fighters of the Military Fire Brigade of Minas Gerais. To met these goals, it has been attempted to analyze the procedures utilized and recommended, nowadays, for the military fire fighters of CBMMG, and through directed studies, to suggest new actions possible to be executed in the local of the emergency in a way that will not expose the garrison to doses of ionizing radiation that may prejudice them. It is a study of bibliographic, exploratory, and also descriptive nature, realized through a qualitative approach. The techniques used for the research were the analysis of institutional documents, norms and other literature produced by renamed entities in the radiologic and biosafety areas. It was then concluded that CBMMG, through simple actions of response, can provide higher quality and safety in the operations involving radiologic accidents, standing out that the implemented actions nowadays are very beneath the capacity of the corporation, due to the lack of knowledge of the matter by the fire fighters. It was proposed, then, that new actions be implemented and instituted as operational procedures to be used on those emergencies, with the objective of provide a higher safety and professionalism in the attendance to emergencies involving radioactive materials. (author)

  19. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Uchelen, J. van; Witter, D.J.; Mulder, J.; Creugers, N.H.J.

    2016-01-01

    This pilot study analyzed impression procedures for conventional metal frame removable partial dentures (RPDs). Heads of RPD departments of three dental laboratories were asked to record features of all incoming impressions for RPDs during a 2-month period. Records included: (1) impression

  20. An improved ring removal procedure for in-line x-ray phase contrast tomography

    Science.gov (United States)

    Massimi, Lorenzo; Brun, Francesco; Fratini, Michela; Bukreeva, Inna; Cedola, Alessia

    2018-02-01

    The suppression of ring artifacts in x-ray computed tomography (CT) is a required step in practical applications; it can be addressed by introducing refined digital low pass filters within the reconstruction process. However, these filters may introduce additional ringing artifacts when simultaneously imaging pure phase objects and elements having a non-negligible absorption coefficient. Ringing originates at sharp interfaces, due to the truncation of spatial high frequencies, and severely affects qualitative and quantitative analysis of the reconstructed slices. In this work, we discuss the causes of ringing artifacts, and present a general compensation procedure to account for it. The proposed procedure has been tested with CT datasets of the mouse central nervous system acquired at different synchrotron radiation facilities. The results demonstrate that the proposed method compensates for ringing artifacts induced by low pass ring removal filters. The effectiveness of the ring suppression filters is not altered; the proposed method can thus be considered as a framework to improve the ring removal step, regardless of the specific filter adopted or the imaged sample.

  1. Test procedures and instructions for single shell tank saltcake cesium removal with crystalline silicotitanate

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.B.

    1997-01-07

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Single Shell Tank Saltcake from tanks 24 t -BY- I 10, 24 1 -U- 108, 24 1 -U- 109, 24 1 -A- I 0 1, and 24 t - S-102, in a bench-scale column. The cesium sorbent to be tested is crystalline siticotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-024, Hanford Single Shell Tank Saltcake Cesium Removal Test Plan.

  2. Procedures Involved in Radioecological Studies with Marine Zooplankton

    International Nuclear Information System (INIS)

    Fowler, S.W.; Small, L.F.

    1976-01-01

    Various procedures in marine radio ecological experiments with zooplankton are considered in the light of the possibility of establishing reference methods for marine radiobiological studies. Methods for collection, handling and maintenance prior to and during experiments are suggested for various types of zooplankton. The importance of physiological and physicochemical parameters are discussed in the context of the experimental design with the aim of achieving comparable results among workers involved in this field of research. (author)

  3. Eye dose to staff involved in interventional and procedural fluoroscopy

    International Nuclear Information System (INIS)

    McLean, D; Hadaya, D; Tse, J

    2016-01-01

    In 2011 the International Commission on Radiological Protection (ICRP) lowered the occupational eye dose limit from 150 to 20 mSv/yr [1]. While international jurisdictions are in a process of adopting these substantial changes, medical physicists at the clinical level have been advising medical colleagues on specific situations based on dose measurements. Commissioned and calibrated TLDs mounted in commercially available holders designed to simulate the measurement of Hp(3), were applied to staff involved in x-ray procedures for a one month period. During this period clinical procedure data was concurrently collected and subject to audit. The use or not of eye personal protective equipment (PPE) was noted for all staff. Audits were conducted in the cardiac catheterisation laboratory, the interventional angiography rooms and the procedural room where endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed. Significant levels of occupational dose were recorded in the cardiac and interventional procedures, with maximum reading exceeding the new limit for some interventional radiologists. No significant eye doses were measured for staff performing ERCP procedures. One outcome of the studies was increased use of eye PPE for operators of interventional equipment with increased availability also to nursing staff, when standing in close proximity to the patient during procedures. (paper)

  4. Removing Contamination-Induced Reconstruction Artifacts from Cryo-electron Tomograms

    Science.gov (United States)

    Fernandez, Jose-Jesus; Laugks, Ulrike; Schaffer, Miroslava; Bäuerlein, Felix J.B.; Khoshouei, Maryam; Baumeister, Wolfgang; Lucic, Vladan

    2016-01-01

    Imaging of fully hydrated, vitrified biological samples by electron tomography yields structural information about cellular protein complexes in situ. Here we present a computational procedure that removes artifacts of three-dimensional reconstruction caused by contamination present in samples during imaging by electron microscopy. Applying the procedure to phantom data and electron tomograms of cellular samples significantly improved the resolution and the interpretability of tomograms. Artifacts caused by surface contamination associated with thinning by focused ion beam, as well as those arising from gold fiducial markers and from common, lower contrast contamination, could be removed. Our procedure is widely applicable and is especially suited for applications that strive to reach a higher resolution and involve the use of recently developed, state-of-the-art instrumentation. PMID:26743046

  5. A note on the implementation of variational procedures involving Green's operators

    Energy Technology Data Exchange (ETDEWEB)

    Blakemore, M; Evans, G A; Hyslop, J

    1975-12-01

    The numerical implementation of a minimum energy principle for atoms and molecules involving integral operators is discussed. It is demonstrated that the use of unscaled trial functions may be as convenient computationally as the earlier procedures involving scaled trial functions and that the revised prescription has advantages, mainly in ease of interpretation and comparison of results. By way of illustration, some earlier calculations on the hydrogen ion are reconsidered and compared. (auth)

  6. A simplified test procedure for determining the effectiveness of adsorbents for the removal of methyl iodide

    International Nuclear Information System (INIS)

    Underhill, D.W.

    1993-01-01

    ASTM Test Procedure D3803 measures the ability of nuclear-grade carbon to remove methyl iodide from a stream of humidified air. This test, unlike all the other procedures developed by ASTM Committee D28, has evolved to become extremely complex. The intricacy of this test as well as the great difficulty in obtaining inter-laboratory agreement, creates doubt as tot the actual meaning of the results. Here a far simpler test system is described in which thermodynamic principles are used to maintain a constant, reproducible test procedure. This paper describes a system implementing these elements, its cost to build, and the factors affecting its accuracy. 11 refs., 1 fig

  7. 8 CFR 208.31 - Reasonable fear of persecution or torture determinations involving aliens ordered removed under...

    Science.gov (United States)

    2010-01-01

    ... HOMELAND SECURITY IMMIGRATION REGULATIONS PROCEDURES FOR ASYLUM AND WITHHOLDING OF REMOVAL Credible Fear of... officer shall review the summary with the alien and provide the alien with an opportunity to correct... determinations under this section shall have the authority described in § 208.9(c). (e) Referral to Immigration...

  8. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    Science.gov (United States)

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  9. 8 CFR 1208.30 - Credible fear determinations involving stowaways and applicants for admission found inadmissible...

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Credible fear determinations involving..., DEPARTMENT OF JUSTICE IMMIGRATION REGULATIONS PROCEDURES FOR ASYLUM AND WITHHOLDING OF REMOVAL Credible Fear of Persecution § 1208.30 Credible fear determinations involving stowaways and applicants for...

  10. Sphincter-saving procedure for radiation-injuried rectum

    International Nuclear Information System (INIS)

    Moriya, Yoshihiro; Koyama, Yasuo; Hojo, Keiichi

    1982-01-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter. (author)

  11. How to Surgically Remove the Permanent Mesh Ring after the Onstep Procedure for Alleviation of Chronic Pain following Inguinal Hernia Repair

    Directory of Open Access Journals (Sweden)

    Stina Öberg

    2016-01-01

    Full Text Available A promising open inguinal hernia operation called Onstep was developed in 2005. The technique is without sutures to the surrounding tissue, causing minimal tension. A specific mesh is used with a memory recoil ring in the border, which may cause pain superficial to the lateral part of the mesh for slender patients. The aim of this study was to illustrate an easy procedure that alleviates/removes the pain. A male patient had persistent pain six months after the Onstep operation and therefore had a ring removal operation. The procedure is presented as a video and a protocol. At the eleven-month follow-up, the patient was free of pain, without a recurrence. It is advised to wait some months after the initial hernia repair before removing the ring, since the mesh needs time to become well integrated into the surrounding tissue. The operation is safe and easy to perform, which is demonstrated in a video.

  12. Ultrasound-assisted oxidative process for sulfur removal from petroleum product feedstock.

    Science.gov (United States)

    Mello, Paola de A; Duarte, Fábio A; Nunes, Matheus A G; Alencar, Mauricio S; Moreira, Elizabeth M; Korn, Mauro; Dressler, Valderi L; Flores, Erico M M

    2009-08-01

    A procedure using ultrasonic irradiation is proposed for sulfur removal of a petroleum product feedstock. The procedure involves the combination of a peroxyacid and ultrasound-assisted treatment in order to comply with the required sulfur content recommended by the current regulations for fuels. The ultrasound-assisted oxidative desulfurization (UAOD) process was applied to a petroleum product feedstock using dibenzothiophene as a model sulfur compound. The influence of ultrasonic irradiation time, oxidizing reagents amount, kind of solvent for the extraction step and kind of organic acid were investigated. The use of ultrasonic irradiation allowed higher efficiency for sulfur removal in comparison to experiments performed without its application, under the same reactional conditions. Using the optimized conditions for UAOD, the sulfur removal was about 95% after 9min of ultrasonic irradiation (20kHz, 750W, run at 40%), using hydrogen peroxide and acetic acid, followed by extraction with methanol.

  13. Sphincter-saving procedure for radiation-injuried rectum. A report of four cases with special reference to pull-through procedure

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Y.; Koyama, Y.; Hojo, K. (National Cancer Center, Tokyo (Japan))

    1982-09-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter.

  14. Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs – Selected aspects

    Directory of Open Access Journals (Sweden)

    Roman Steckiewicz

    2017-06-01

    Full Text Available Background: Some cardiac implantable electronic device (CIED implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated. Material and Methods: This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement procedures in 176 women and 346 men (mean age 75±11 years over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM and 171 implantable cardioverter-defibrillator (ICD implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results: We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions: Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3:363–374

  15. 14 CFR 302.211 - Procedures in certificate cases involving initial or continuing fitness.

    Science.gov (United States)

    2010-01-01

    ... initial or continuing fitness. 302.211 Section 302.211 Aeronautics and Space OFFICE OF THE SECRETARY... Disposition of Applications § 302.211 Procedures in certificate cases involving initial or continuing fitness... applicant's fitness to operate. Where such applications propose the operation of scheduled service in...

  16. Surgical resident involvement is safe for common elective general surgery procedures.

    Science.gov (United States)

    Tseng, Warren H; Jin, Leah; Canter, Robert J; Martinez, Steve R; Khatri, Vijay P; Gauvin, Jeffrey; Bold, Richard J; Wisner, David; Taylor, Sandra; Chen, Steven L

    2011-07-01

    Outcomes of surgical resident training are under scrutiny with the changing milieu of surgical education. Few have investigated the effect of surgical resident involvement (SRI) on operative parameters. Examining 7 common general surgery procedures, we evaluated the effect of SRI on perioperative morbidity and mortality and operative time (OpT). The American College of Surgeons National Surgical Quality Improvement Program database (2005 to 2007) was used to identify 7 cases of nonemergent operations. Cases with simultaneous procedures were excluded. Logistic regression was performed across all procedures and within each procedure incorporating SRI, OpT, and risk-stratifying American College of Surgery National Surgical Quality Improvement Program morbidity and mortality probability scores, which incorporate multiple prognostic individual patient factors. Procedure-specific, SRI-stratified OpTs were compared using Wilcoxon rank-sum tests. A total of 71.3% of the 37,907 cases had SRI. Absolute 30-day morbidity for all cases with SRI and without SRI were 3.0% and 1.0%, respectively (p < 0.001); absolute 30-day mortality for all cases with SRI and without SRI were 0.1% and 0.08%, respectively (p < 0.001). After multivariate analysis by specific procedure, SRI was not associated with increased morbidity but was associated with decreased mortality during open right colectomy (odds ratio 0.32; p = 0.01). Across all procedures, SRI was associated with increased morbidity (odds ratio 1.14; p = 0.048) but decreased mortality (odds ratio 0.42; p < 0.001). Mean OpT for all procedures was consistently lower for cases without SRI. SRI has a measurable impact on both 30-day morbidity and mortality and OpT. These data have implications to the impact associated with surgical graduate medical education. Further studies to identify causes of patient morbidity and prevention strategies in surgical teaching environments are warranted. Copyright © 2011 American College of Surgeons

  17. Fatal Phenol Toxicity Following Attempted Tattoo Removal.

    Science.gov (United States)

    Li, Zhen; Zhang, Huang; Li, Shu-Hua; Byard, Roger W

    2016-07-01

    Tattoo removal is increasingly required as the number of, particularly young, people acquiring tattoos is increasing. A 21-year-old man is reported who underwent attempted removal of large dragon tattoo utilizing a tattoo machine that injected a phenol-containing solution. At the end of the 3-h procedure, he collapsed and died. At autopsy, large areas of white skin discoloration with focal necrosis and sloughing were present overlying areas of previous tattooing. Histological examination showed collections of eosinophilic fluid with a minimal chronic inflammatory infiltrate in better preserved areas, with focal areas of dermal necrosis. Toxicology was positive for phenol in cardiac blood and liver tissue. There were no underlying organic disease or injuries present which could have caused or contributed to death. This idiosyncratic method of tattoo removal involving subcutaneous injection of phenol had resulted in death most likely from cardiotoxicity. © 2016 American Academy of Forensic Sciences.

  18. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  19. Pectus bar removal: surgical technique and strategy to avoid complications.

    Science.gov (United States)

    Park, Hyung Joo; Kim, Kyung Soo

    2016-01-01

    Pectus bar removal is the final stage of the procedure for minimally invasive repair of pectus excavatum. Based on our experience with one of the largest scale data, we would like to address the important issues in pectus bar removal, such as appropriate duration of bar maintenance, techniques for bar removal, and strategies to avoid complications. Between September 1999 and August 2015, we operated on 2,553 patients with pectus excavatum and carinatum using pectus bars for a minimally invasive approach. Among them, 1,821 patients (71.3%) underwent pectus bar removal as a final stage of pectus deformity repair, and their data were analyzed retrospectively to identify the outcomes and adverse effects of the pectus bar removal procedure. The mean age of the patients was 9.13 years (range, 16 months to 44 years) and the male to female ratio was 3.55. The study is approved by the Institutional Review Board (IRB), the ethical committee of Seoul St. Mary's Hospital. The IRB has exempted the informed consent from every patient in this study due to this is a retrospective chart review without revealing any patients' personal data. Our technique involved straightening of the bar in a supine position. The overall mean duration of pectus bar maintenance was 2.57 years (range, 4 months to 14 years). The mean duration was 2.02 years (range, 4 months to 7 years) for children under 12 years, 2.99 years (range, 7 months to 9 years) for teenagers aged 12-20 years, and 3.53 years (range, 3 months to 14 years) for adults over 20 years. Forty-eight patients (2.6%) underwent bar removal more than 5 years after bar insertion and 58 patients (3.2%) underwent bar removal earlier than initially planned. The most common adverse reaction after bar removal was wound seroma including infection (43 patients, 2.36%). Recurrence after bar removal occurred in nine patients (0.49%), and seven of these required redo repair (0.38%). Pectus bar removal is a safe and straightforward procedure with a

  20. Patients' satisfaction with the Nuss procedure

    International Nuclear Information System (INIS)

    Ishimaru, Tetsuya; Iwanaka, Tadashi; Uchida, Hiroo; Kawashima, Hiroshi; Gotoh, Chikashi; Satoh, Kaori; Yoshida, Mariko; Kitano, Yoshihiro

    2009-01-01

    The purpose of this study is to investigate the satisfaction of patients who have already finished bar removal. Fifty-four patients with pectus excavatum underwent the Nuss procedure between July 2000 and December 2007 and the bar was removed in 41 of them at our hospital. A telephone questionnaire was administered to their parents or the patients (12 years old or older). The questions were as follows: self-assessment of the present thoracic form on a 5-point scale, whether it was good to have undergone the Nuss procedure (Y/N), whether the patient will recommend this procedure to another patient (Y/N). Thirty-nine patients responded to the questionnaire. Median age at the bar insertion was 83 months (range: 63-189 months). The bar was removed about 2 years after the initial operation. The median period after removal was 29 months ( range: 2-65 months). The mean point for the thoracic form was 4.2 (5 points: 20, 4 points: 11, 3 points: 5, 2 points: 3). Thirty-eight patients answered that they were satisfied with this procedure. Thirty-four patients answered that they would recommend this procedure to another patient. Eight patients reported that redepression occurred after bar removal. Six of them are under observation because their thoracic deformity is mild. Patients' satisfaction with the Nuss procedure was high. However, our study shows the possibility of post-removal recurrence. There seems to be a tendency for patients to assess their thoracic form more strictly than the doctors. (author)

  1. Advantages of using microbial technology over traditional chemical technology in removal of black crusts from stone surfaces of historical monuments.

    Science.gov (United States)

    Cappitelli, Francesca; Toniolo, Lucia; Sansonetti, Antonio; Gulotta, Davide; Ranalli, Giancarlo; Zanardini, Elisabetta; Sorlini, Claudia

    2007-09-01

    This study compares two cleaning methods, one involving an ammonium carbonate-EDTA mixture and the other involving the sulfate-reducing bacterium Desulfovibrio vulgaris subsp. vulgaris ATCC 29579, for the removal of black crust (containing gypsum) on marble of the Milan Cathedral (Italy). In contrast to the chemical cleaning method, the biological procedure resulted in more homogeneous removal of the surface deposits and preserved the patina noble under the black crust. Whereas both of the treatments converted gypsum to calcite, allowing consolidation, the chemical treatment also formed undesirable sodium sulfate.

  2. Advantages of Using Microbial Technology over Traditional Chemical Technology in Removal of Black Crusts from Stone Surfaces of Historical Monuments▿

    Science.gov (United States)

    Cappitelli, Francesca; Toniolo, Lucia; Sansonetti, Antonio; Gulotta, Davide; Ranalli, Giancarlo; Zanardini, Elisabetta; Sorlini, Claudia

    2007-01-01

    This study compares two cleaning methods, one involving an ammonium carbonate-EDTA mixture and the other involving the sulfate-reducing bacterium Desulfovibrio vulgaris subsp. vulgaris ATCC 29579, for the removal of black crust (containing gypsum) on marble of the Milan Cathedral (Italy). In contrast to the chemical cleaning method, the biological procedure resulted in more homogeneous removal of the surface deposits and preserved the patina noble under the black crust. Whereas both of the treatments converted gypsum to calcite, allowing consolidation, the chemical treatment also formed undesirable sodium sulfate. PMID:17601804

  3. String Technique for Anterior Orbital Fish Hook Removal.

    Science.gov (United States)

    Starr, Matthew R; Choi, Michael B; Mahr, Michael A; Mettu, Pradeep; Patterson, David F

    2018-06-13

    Removing fish hooks is a common procedure performed by many emergency department providers. There are several techniques that are commonly employed to aid in successful removal. However, when a fish hook becomes embedded within the orbit, there are limited options as to avoid damaging vital surrounding structures. The authors report the removal of a fish hook within the anterior orbit using the string technique in a 25-year-old patient. The procedure was performed under general anesthesia with the aid of size 5 polyglactin suture wrapped around the hook. The procedure itself took less than 10 seconds and was successful in swiftly and safely removing the hook without damaging surrounding orbital structures. The patient recovered well without any permanent sequelae.

  4. Risk-based equipment removal guide for on-line maintenance at PSE ampersand G

    International Nuclear Information System (INIS)

    Knoll, A.; Smith, C.; Pollock, J.

    1995-01-01

    On-line maintenance plays an important role in achieving safe and reliable power generation in a nuclear power plant. However, maintenance, if not properly planned and performed, may also be an important contributor to plant risk. Therefore, plant-specific procedures are needed for equipment removal from service to enhance the benefits of on-line maintenance and minimize the risks involved. The problem is to identify and implement the most effective on-line maintenance policy in the form of a proceduralized guide to assure plant safety under various operation and maintenance constraints. This paper presents a methodology to develop plant-specific on-line maintenance strategies and acceptance criteria using a multivariate safety approach based on risk assessment. Based on plant-specific data as modeled in the individual plant evaluation (IPE) and the updated probabilistic safety assessment (PSA), the risk-based methodology is currently being applied to the development of proceduralized equipment removal guides at Hope Creek and Salem units 1 and 2 of Public Service Electric and Gas Company (PSE ampersand G)

  5. Evaluation of asbestos exposure within the automotive repair industry: a study involving removal of asbestos-containing body sealants and drive clutch replacement.

    Science.gov (United States)

    Blake, Charles L; Dotson, G Scott; Harbison, Raymond D

    2008-12-01

    Two independent assessments were performed of airborne asbestos concentrations generated during automotive repair work on vintage vehicles . The first involved removal of asbestos-containing seam sealant, and the second involved servicing of a drive clutch. Despite the relatively high concentrations (5.6-28%) of chrysotile fibers detected within bulk samples of seam sealant, the average asbestos concentration for personal breathing zone (PBZ) samples during seam sealant removal was 0.006 f/cc (fibers/cubic centimeter of air). Many other air samples contained asbestos at or below the analytical limit of detection (LOD). Pneumatic chiseling of the sealant material during removal resulted in 69% of area air samples containing asbestos. Use of this impact tool liberated more asbestos than hand scraping. Asbestos fibers were only detected in air samples collected during the installation of a replacement clutch. The highest asbestos corrected airborne fiber concentration observed during clutch installation was 0.0028 f/cc. This value is approximately 100 times lower than Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) of 0.1f/cc. The airborne asbestos concentrations observed during the servicing of vintage vehicles with asbestos-containing seam sealant and clutches are comparable to levels reported for repair work involving brake components and gaskets.

  6. Firefighter Down! How to Rapidly Remove Turnout Gear.

    Science.gov (United States)

    ALexander, John G

    2016-04-01

    The rescue of an injured colleague--and probably a good friend--is an emotionally charged event. A common initial response could be to remove everything as quickly as possible. Keep in mind that we have accepted practices for the removal of motorcycle equipment and football gear. There are also procedures for removing a patient from a vehicle or swimming pool. These all exist to protect a patient from further injury. We now have established practices for removing a firefighter from a window, or down a ladder. Why then do the procedures stop? Once a firefighter is rescued from a hot zone, he deserves the same level of consideration a football player, motorcycle rider or any other patient receives. We should not be in such a hurry that we don't care how we remove a protective ensemble. The injured firefighter deserves a system, or a procedure, that may be practiced by others and reduce the chance of further injury during

  7. Technique for the Laparoscopic Removal of Essure Microinserts.

    Science.gov (United States)

    Mahmoud, Mohamad S

    2016-01-01

    To describe our technique for the laparoscopic removal of Essure microinserts (Bayer HealthCare Pharmaceuticals Inc., Whippany, NJ). Step-by-step explanation of the procedure using video (Canadian Task Force classification III). Hysteroscopic sterilization using tubal microinsert devices has generally been reported to be well tolerated in terms of procedure-related pain. Persistent pelvic pain requiring microinsert removal has been described in a few case reports and series and was estimated at 0.16% of cases (7 cases [49/4,274]) in a large retrospective study. Removal is usually performed at the patient's request and/or because of persistent pelvic pain unresponsive to other treatments with no other etiologies found. In general, the pain starts at the initial insertion and persists thereafter. Both laparoscopic and hysteroscopic removal approaches have been described in the few cases reported. In this video, we describe our technique for the surgical management of pelvic pain resulting from Essure microinserts. We performed laparoscopic removal of bilateral Essure microinserts in a 30-year-old G3P3 (Gravida 3 Para 3) with bilateral Essure devices placed 2 years before the procedure; hysterosalpingogram confirmed appropriate placement. The patient was suffering from bilateral sharp pelvic pain since insertion that was related to positional change and movements but unrelated to periods along with menorrhagia. A pelvic ultrasound showed a small intramural uterine leiomyoma. She failed a trial of treatment of her symptoms with a levonorgestrel intrauterine device. The patient requested removal of her Essure microinserts and endometrial ablation. She underwent laparoscopic bilateral Essure microinsert removal and bilateral salpingectomy along with hysteroscopic removal of the levonorgestrel intrauterine device and endometrial ablation. Her surgery was uneventful, and she was discharged the day of the surgery. Her symptoms resolved completely after the procedure

  8. Issues involved in a knowledge-based approach to procedure synthesis

    International Nuclear Information System (INIS)

    Hajek, B.K.; Khartabil, L.F.; Miller, D.W.

    1992-01-01

    Many knowledge-based systems (KBSs) have been built to assist human operators in managing nuclear power plant operating functions, such as monitoring, fault diagnosis, alarm filtering, and procedure management. For procedure management, KBSs have been built to display and track existing written procedures or to dynamically follow procedure execution by monitoring plant data and action execution and suggesting recovery steps. More recent works build KBSs able to synthesize procedures. This paper addresses and examines the main issues related to the implementation of on-line procedure synthesis using KBSs. A KBS for procedure synthesis can provide a more robust and effective procedural plan during accidents. Currently existing procedures for abnormal plant conditions, written as precompiled step sets based on the event and symptom approaches, are inherently not robust because anticipation of all potential plant states and associated plant responses is not possible. Thus, their failure recovery capability is limited to the precompiled set. Procedure synthesis has the potential to overcome these two problems because it does not require such precompilation of large sets of plant states and associated recovery procedures. Other benefits obtained from a complete procedure synthesis system are providing (a) a methodology for off-line procedure verification and (b) a methodology for the eventual automation of plant operations

  9. Effect of bleaching and repolishing procedures on coffee and tea stain removal from three anterior composite veneering materials.

    Science.gov (United States)

    Türkün, L Sebnem; Türkün, Murat

    2004-01-01

    Discolored teeth can be treated with resin veneers, but their color changes when confronted with staining solutions. Polishing procedures can provide a remedy for highly stained composites, but they tend to remove some materials as well. However, bleaching procedures are an effective, nondestructive method for solving the problem. The aim of this study was to compare the color change of three veneer composites exposed to staining solutions and to evaluate the effectiveness of a 15% hydrogen peroxide bleaching agent and three polishing systems to remove the stain. Forty-five disks (12 x 2 mm) each of Clearfil ST (Kuraray Co. Ltd., Osaka, Japan), Esthet-X (Dentsply/Caulk, Milford DE, USA), and Filtek A110 (3M ESPE, St. Paul, MN, USA) were prepared. The specimens were polished with Sof-Lex (3M ESPE), Enhance (Dentsply/Caulk), or PoGo (Dentsply/Caulk). Five specimens for each material-polishing system combination were immersed in coffee (Nescafe Classic, Nestle SA, Vevey, Switzerland) or tea (Earl Grey, Lipton, Blackfriars-London, England) for 7 days. The remaining disks were stored in water. Color measurements were made with a spectrophotometer (X-Rite Seroice SP78, Loaner, Köln, Germany) at baseline; after 1, 3, 5, and 7 days; and after bleaching and repolishing. After 1 week, one side of the specimens was bleached with Illuminé-office (Dentsply De Trey GmbH, Konstanz, Germany) for 1 hour, and the other side was repolished for 30 seconds. All comparisons of color change for the polishing systems, times, and staining solutions were subjected to repeated measurements of analysis of variance. Paired t-test was used to examine whether significant color differences (deltaE*) occurred during immersion at the specified time intervals (p < or = .05). Filtek A110 was the least stained resin composite. Its color remained under a deltaE* value of 2 during the study. Clearfil ST exhibited the most color change after 1 week. All specimens polished with Enhance showed less

  10. 34 CFR 300.536 - Change of placement because of disciplinary removals.

    Science.gov (United States)

    2010-07-01

    ... THE EDUCATION OF CHILDREN WITH DISABILITIES Procedural Safeguards Due Process Procedures for Parents and Children Discipline Procedures § 300.536 Change of placement because of disciplinary removals. (a... 34 Education 2 2010-07-01 2010-07-01 false Change of placement because of disciplinary removals...

  11. Regulatory compliance issues related to the White Oak Creek Embayment time-critical removal action

    International Nuclear Information System (INIS)

    Leslie, M.; Kimmel, B.L.

    1992-01-01

    In September 1990, Martin Marietta Energy Systems (Energy Systems) discovered high levels of Cesium-137 present in surface sediments at the mouth of White Oak Creek (WOC) Embayment. WOC receives the majority of surface water drainage from Oak Ridge National Laboratory. Following this discovery, the Department of Energy (DOE) and Energy Systems pursued stabilizing sediment migration under provisions of the National Contingency Plan (NCP) Section 300.400 et. seq. as a time-critical removal action. However, significant uncertainty exists concerning the applicability of NCP procedural requirements designed for conducting US EPA-led, Superfund-financed response actions, because NCP Subpart K dealing with response actions at federal facilities has not been promulgated. In addition, relatively new guidance exists from DOE concerning National Environmental Policy Act documentation requirements for categorical exclusions associated with conducting removal actions at DOE facilities. A proactive approach was taken to identify issues and involve appropriate state and federal regulatory agencies. This approach required achieving consensus among all involved parties and identification of all applicable or relevant and appropriate regulatory requirements related to the removal action. As a result, this project forms a framework for conducting future time-critical removal actions at federal facilities

  12. Lung Middle Lobe Laceration Needing Lobectomy as Complication of Nuss Bar Removal.

    Science.gov (United States)

    Henry, Brice; Lacroix, Valérie; Pirotte, Thierry; Docquier, Pierre-Louis

    2018-01-01

    Minimally invasive procedure for the treatment of pectus excavatum as described by Nuss has been used from 1987. The bar initially introduced blindly is now introduced under thoracoscopic control to increase safety of the procedure. It is usually removed two to three years after its insertion in a one-day procedure. Complications of the bar removal are rare but potentially serious. We report the case of a serious complication which occurred immediately after the Nuss bar removal. A 15-year-old boy underwent a Nuss procedure for a severe pectus excavatum without relevant complication. The bar has been removed two years after its insertion in a minimally invasive procedure. Unfortunately, he developed in the immediate postoperative period a hemopneumothorax due to a right middle lobe laceration which required a middle lobectomy by thoracotomy for hemostasis. Lesions of intrathoracic organs are a rare but potentially serious complication of the removal of the Nuss bar. We now propose to perform this procedure under thoracoscopic control to avoid it. In our experience, adhesions between the bar and the pleura are always present, and those with potential risk for bleeding or inducing intrathoracic organ lesions are suppressed prior to the bar removal.

  13. Using metagenomics and metatranscriptomics to study specific bacterial species involved in biological phosphorus removal from wastewater

    DEFF Research Database (Denmark)

    Albertsen, Mads; McIlroy, Simon Jon; Stokholm-Bjerregaard, Mikkel

    an enrichment of the target organisms in laboratory scale reactors under controlled conditions. We demonstrate that it is now easy and affordable to extract genomes of all the dominant organisms from reactors due to reduced micro-diversity and further use these to examine their individual gene expression...... profiles by metatranscriptomics. To demonstrate this we revisited the bacteria involved in enhanced biological phosphorus removal (EBPR) from wastewater treatment plants. The EBPR process is used all over the world, has a large body of information regarding the underlying microbiology, and is often studied...

  14. Three additional genes involved in pyrimidine dimer removal in Saccharomyces cerevisiae: RAD7, RAD14, and MMS19

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, L; Prakash, S

    1979-01-01

    The ability to remove ultraviolet (uv)-induced pyrimidine dimers from the nuclear DNA of yeast was examined in two radiation-sensitive (rad) mutants and one methyl methanesulfonate-sensitive (mms) mutant of the yeast Saccharomyces cerevisiae. The susceptibility of DNA from irradiated cells to nicking by an endonuclease activity prepared from crude extracts of Micrococcus luteus was used to measure the presence of dimers in DNA. The rad7, rad14, and mms19 mutants were found to be defective in their ability to remove uv-induced dimers from nuclear DNA. All three mutants belong to the same episatic group as the other mutants involved in excision-repair. All three mutants show enhanced uv-induced mutations. The rad 14 mutant also shows epistatic interactions with genes in the other two uv repair pathways.

  15. A new methodology for assessment of pectus excavatum correction after bar removal in Nuss procedure: Preliminary study.

    Science.gov (United States)

    Gomes-Fonseca, João; Vilaça, João L; Henriques-Coelho, Tiago; Direito-Santos, Bruno; Pinho, António C M; Fonseca, Jaime C; Correia-Pinto, Jorge

    2017-07-01

    The objective is to present a new methodology to assess quantitatively the impact of bar removal on the anterior chest wall, among patients with pectus excavatum who have undergone the Nuss procedure, and present a preliminary study using this methodology. We propose to acquire, for each patient, the surface of the anterior chest wall using a three-dimensional laser scanner at subsequent time points (short term: before and after surgery; long term: follow-up visit, 6months, and 12months after surgery). After surfaces postprocessing, the changes are assessed by overlapping and measuring the distances between surfaces. In this preliminary study, three time points were acquired and two assessments were performed: before vs after bar removal (early) and before vs 2-8weeks after bar removal (interim). In 21 patients, the signed distances and volumes between surfaces were computed and the data analysis was performed. This methodology revealed useful for monitoring changes in the anterior chest wall. On average, the mean, maximum, and volume variations, in the early assessment, were -0.1±0.1cm, -0.6±0.2cm, and 47.8±22.2cm 3 , respectively; and, in the interim assessment, were -0.5±0.2cm, -1.3±0.4cm, and 122.1±47.3cm 3 , respectively (pbar was in situ was inversely and significantly correlated with postretraction and was a relevant predictor of its decrease following surgery (pbar was in situ may be the main determinant of the anterior chest wall retraction following bar removal. Further studies should continue to corroborate and reinforce the preliminary findings, by increasing the sample size and performing long-term assessments. III. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Quality assurance project plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-03-01

    This quality assurance project plan defines project organization and roles of responsibility, sampling and field procedures, sample documentation and chain-of-custody protocols, equipment calibration, analytical procedures, data reduction and validation, and internal quality control procedures for the former YS-860 Firing Ranges removal action at the Oak Ridge Y-12 Plant. The ENTECH Team will maintain the highest standards to ensure strict compliance with this plan. Implementation of this plan will include consideration of the technical, as well as administrative, aspects of activities affecting quality. Plan implementation is based on the premise that quality controls selected for each element of work are consistent with the risk, importance, and health and safety considerations of performing the work. The purpose of this removal action is to address lead-contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of two small arms firing ranges. This plan covers the removal action at the former YS-86O Firing Ranges. These actions involve the excavation of lead-contaminated soils, the removal of the concrete trench and macadam (asphalt) paths, verification sampling, grading, and revegetation

  17. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.

    Science.gov (United States)

    Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh

    2014-12-01

    With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.

  19. Removal of soluble toxic metals from water

    International Nuclear Information System (INIS)

    Buckley, L.P.; Vijayan, S.; McConeghy, G.J.; Maves, S.R.; Martin, J.F.

    1990-05-01

    The removal of selected, soluble toxic metals from aqueous solutions has been accomplished using a combination of chemical treatment and ultrafiltration. The process has been evaluated at the bench-scale and is undergoing pilot-scale testing. Removal efficiencies in excess of 95-99% have been realized. The test program at the bench-scale investigated the limitations and established the optimum range of operating parameters for the process, while the tests conducted with the pilot-scale process equipment are providing information on longer-term process efficiencies, effective processing rates, and fouling potential of the membranes. With the typically found average concentrations of the toxic metals in groundwaters at Superfund sites used as the feed solution, the process has decreased levels up to 100-fold or more. Experiments were also conducted with concentrated solutions to determine their release from silica-based matrices. The solidified wastes were subjected to EP Toxicity test procedures and met the criteria successfully. The final phase of the program involving a field demonstration at a uranium tailings site will be outlined

  20. Guidelines for removing permanent makeup

    Directory of Open Access Journals (Sweden)

    C.Bettina Rümmelein

    2016-09-01

    Full Text Available Permanent makeup (PMU is a frequently implemented cosmetic procedure performed by beauticians. From a technical point, PMU is considered a facial tattoo. Failed procedures or a change of mind can lead to the desire for removal. The purpose of this retrospective evaluation of patients who came to the clinic with the desire to remove PMU between 2011 and 2015 was to explore the problems, side effects, and results in order to define treatment guidelines for other doctors. We evaluated 87 individual cases in total. In treatable cases, i.e. 52 out of the 87 cases, laser treatments were performed using a nanosecond Q-switched neodymium-doped yttrium aluminium garnet (Nd:YAG laser. It takes between 1-12 treatments to remove the PMU. In three cases, the colour of the PMU could not be removed by laser and remained after the treatment. In two cases, laser treatment had to be terminated due to colour changes towards the green-blue spectrum. Before PMU removal, laser test shots are urgently recommended as unforeseeable colour changes can cause severe aesthetically unpleasant results. Covered up PMU (skin colour is particularly susceptible to changes in colour. Heat-induced shrinking of the eye area can cause an ectropium. Surgical solutions also have to be taken into consideration. The use of proper eye protection with intraocular eye shields is mandatory. This article is an attempt to set up some guidelines for the treatment of PMU removal.

  1. The effect of trainee involvement on procedure and list times: A statistical analysis with discussion of current issues affecting orthopaedic training in UK.

    Science.gov (United States)

    Wilson, T; Sahu, A; Johnson, D S; Turner, P G

    2010-02-01

    Training surgeons adds time to the duration of procedures and operation lists. This is not accounted for in the finance received to perform the operation by the hospital in the Payment by Results (PbR) system. To find out: 1. The effect on the duration of a procedure and the number of procedures performed on the list when a trainee is involved. 2. The percentage of orthopaedic cases with trainee involvement. 3. The effect of European working time directive (EWTD) on the trainee involvement in cases from theatre data in 2008 versus logbook data from 2004 - 2008. Data was taken from two different sources. Firstly, the Operating Room Information System (ORMIS) and patient operation notes. The second source was a consultant's logbook comprising 227 primary total knee replacements performed between 2004 and 2008. The data produced trends suggesting trainees took longer to perform procedures than consultants. In orthopaedic operations, 92% of cases had trainees present and of these 17% of cases were performed by trainees in 2008. Before the implementation of the EWTD, trainees performed more procedures when compared with current logbook data (38% versus 17% cases). Time taken by a trainee to perform the procedure under direct consultant supervision was significantly higher in comparison to procedures performed by a consultant alone (P = < 0.0001). Analysing the ORMIS and logbook data gave similar conclusions. Hospitals should be given financial recognition for training. In this debate, we should remain focused on the provision of quality training for the next generation of surgeons.

  2. Sodium removal, storage, and requalification of components

    International Nuclear Information System (INIS)

    Gallegos, A.; Shimazaki, T.; Oliva, R.M.

    1974-01-01

    The objectives of this program are to devise, develop, test, and evaluate techniques for sodium removal and storage of test specimens and components, and to expand and refine, by test and analysis, the sodium removal and storage techniques and procedures for use in processing typical LMFBR components

  3. Removal of root filling materials.

    LENUS (Irish Health Repository)

    Duncan, H.F. Chong, B.S.

    2011-05-01

    Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.

  4. Intentional placental removal on suspicious placenta accreta spectrum: still prohibited?

    Science.gov (United States)

    Matsubara, Shigeki; Takahashi, Hironori

    2018-01-01

    Intentional placental removal for abnormally invasive placenta (AIP) is fundamentally abandoned at planned surgery for it. Whether this holds true even after recent introduction of various hemostatic procedures is unclear. We discussed on this issue based on our own experiences and also on the recent reports on various hemostatic procedures. Studies directly answering this question have been lacking. We must weigh the balance between the massive bleeding and possibility of uterus-preservation when intentional placental removal strategy is employed. An almost forgotten strategy, the "intentional placental removal" for planned AIP surgery may regain its position when appropriate hemostatic procedures are concomitantly used depending on the situation. Even employing this strategy, quick decision to perform hysterectomy under multidisciplinary team may be important.

  5. Prevention of Cutaneous Tissue Contracture During Removal of Craniofacial Implant Superstructures for CT and MRI Studies

    Directory of Open Access Journals (Sweden)

    Maureen Sullivan

    2010-04-01

    Full Text Available Objectives: Head and neck cancer patients who have lost facial parts following surgical intervention frequently require craniofacial implant retained facial prostheses for restoration. Many craniofacial implant patients require computed tomography and magnetic resonance imaging scans as part of their long-term follow-up care. Consequently removal of implant superstructures and peri-abutment tissue management is required for those studies. The purpose of the present paper was to describe a method for eliminating cranial imaging artifacts in patients with craniofacial implants.Material and Methods: Three patients wearing extraoral implant retained facial prostheses needing either computed tomography or magnetic resonance imaging studies were discussed. Peri-implant soft tissues contracture after removal of percutaneous craniofacial implant abutments during computed tomography and magnetic resonance imaging studies was prevented using a method proposed by authors. The procedure involves temporary removal of the supra-implant components prior to imaging and filling of the tissue openings with polyvinyl siloxane dental impression material.Results: Immediately after filling of the tissue openings with polyvinyl siloxane dental impression material patients were sent for the imaging studies, and were asked to return for removal of the silicone plugs and reconnection of all superstructure hardware after imaging procedures were complete. The silicone plugs were easily removed with a dental explorer. The percutaneous abutments were immediately replaced and screwed into the implants which were at the bone level.Conclusions: Presented herein method eliminates the source of artifacts and prevents contracture of percutaneous tissues upon removal of the implant abutments during imaging.

  6. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1984-12-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training the head was safely removed and stored and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  7. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1985-09-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 (TMI-2) reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training, the head was safely removed and stored; and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  8. An XML Representation for Crew Procedures

    Science.gov (United States)

    Simpson, Richard C.

    2005-01-01

    NASA ensures safe operation of complex systems through the use of formally-documented procedures, which encode the operational knowledge of the system as derived from system experts. Crew members use procedure documentation on the ground for training purposes and on-board space shuttle and space station to guide their activities. Investigators at JSC are developing a new representation for procedures that is content-based (as opposed to display-based). Instead of specifying how a procedure should look on the printed page, the content-based representation will identify the components of a procedure and (more importantly) how the components are related (e.g., how the activities within a procedure are sequenced; what resources need to be available for each activity). This approach will allow different sets of rules to be created for displaying procedures on a computer screen, on a hand-held personal digital assistant (PDA), verbally, or on a printed page, and will also allow intelligent reasoning processes to automatically interpret and use procedure definitions. During his NASA fellowship, Dr. Simpson examined how various industries represent procedures (also called business processes or workflows), in areas such as manufacturing, accounting, shipping, or customer service. A useful method for designing and evaluating workflow representation languages is by determining their ability to encode various workflow patterns, which depict abstract relationships between the components of a procedure removed from the context of a specific procedure or industry. Investigators have used this type of analysis to evaluate how well-suited existing workflow representation languages are for various industries based on the workflow patterns that commonly arise across industry-specific procedures. Based on this type of analysis, it is already clear that existing workflow representations capture discrete flow of control (i.e., when one activity should start and stop based on when other

  9. 21 CFR 56.110 - Expedited review procedures for certain kinds of research involving no more than minimal risk...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Expedited review procedures for certain kinds of research involving no more than minimal risk, and for minor changes in approved research. 56.110 Section 56.110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  10. Semi-Automatic Removal of Foreground Stars from Images of Galaxies

    Science.gov (United States)

    Frei, Zsolt

    1996-07-01

    A new procedure, designed to remove foreground stars from galaxy proviles is presented here. Although several programs exist for stellar and faint object photometry, none of them treat star removal from the images very carefully. I present my attempt to develop such a system, and briefly compare the performance of my software to one of the well-known stellar photometry packages, DAOPhot (Stetson 1987). Major steps in my procedure are: (1) automatic construction of an empirical 2D point spread function from well separated stars that are situated off the galaxy; (2) automatic identification of those peaks that are likely to be foreground stars, scaling the PSF and removing these stars, and patching residuals (in the automatically determined smallest possible area where residuals are truly significant); and (3) cosmetic fix of remaining degradations in the image. The algorithm and software presented here is significantly better for automatic removal of foreground stars from images of galaxies than DAOPhot or similar packages, since: (a) the most suitable stars are selected automatically from the image for the PSF fit; (b) after star-removal an intelligent and automatic procedure removes any possible residuals; (c) unlimited number of images can be cleaned in one run without any user interaction whatsoever. (SECTION: Computing and Data Analysis)

  11. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-28

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the Lead Source Removal Project at the Former YS-86O Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. This plan covers the removal actions at the Former YS-86O Firing Ranges. These actions involve the excavation of lead-contaminated soils, the removal of the concrete trench and macadam (asphalt) paths, verification/confirmation sampling, grading and revegetation. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects.

  12. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-01-01

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the Lead Source Removal Project at the Former YS-86O Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. This plan covers the removal actions at the Former YS-86O Firing Ranges. These actions involve the excavation of lead-contaminated soils, the removal of the concrete trench and macadam (asphalt) paths, verification/confirmation sampling, grading and revegetation. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects

  13. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    Science.gov (United States)

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  14. Investigating the removal of body piercings.

    Science.gov (United States)

    Armstrong, Myrna L; Roberts, Alden E; Koch, Jerome R; Saunders, Jana C; Owen, Donna C

    2007-05-01

    Although body piercing procurement continues to increase, 13% to 18% of them are removed. Reasons for piercing removal in college students were examined with three groups: (a) those who kept all their piercings, (b) those who removed some, or (c) those who removed all of their body piercings. Of the sample, 41% were still pierced; 50% in their lifetime. Their major purpose for the body piercing was "helped them feel unique." Females obtained more (in high school) and then removed more, usually as upperclassmen. Males and females reported themselves as risk takers at procedure time and currently; however, only 10% cited deviancy as a reason for the body piercing(s). Only removal elements of "I just got tired of it" and "I just decided to remove it" were present, especially with the Some Removed Group. Further examination of body piercing building personal distinctiveness and self-identity to promote their need of uniqueness is suggested.

  15. Fluoroscopy-Guided Removal of Pull-Type Gastrostomy Tubes

    International Nuclear Information System (INIS)

    Ahlers, Christopher M.; Schneider, Jens; Lachmann, Ricarda; Herber, Sascha; Dueber, Christoph; Pitton, Michael B.

    2008-01-01

    These case reports demonstrate a radiologic interventional technique for removal of pull-type gastrostomy tubes. This approach proved to be a safe and efficient procedure in two patients. The procedure may be applicable in situations where endoscopic attempts fail.

  16. A-Cell equipment removal quality process plan

    International Nuclear Information System (INIS)

    TAKASUMI, D.S.

    1999-01-01

    This document establishes the quality assuring activities used to manage the 324 building A-Cell equipment removal activity. This activity will package, remove, transport and dispose of the equipment in A-Cell. This document is provided to ensure that appropriate and effective quality assuring activities have been incorporated into the work controlling documentation and procedures

  17. TMI-2 reactor-vessel head removal and damaged-core-removal planning

    International Nuclear Information System (INIS)

    Logan, J.A.; Hultman, C.W.; Lewis, T.J.

    1982-01-01

    A major milestone in the cleanup and recovery effort at TMI-2 will be the removal of the reactor vessel closure head, planum, and damaged core fuel material. The data collected during these operations will provide the nuclear power industry with valuable information on the effects of high-temperature-dissociated coolant on fuel cladding, fuel materials, fuel support structural materials, neutron absorber material, and other materials used in reactor structural support components and drive mechanisms. In addition, examination of these materials will also be used to determine accident time-temperature histories in various regions of the core. Procedures for removing the reactor vessel head and reactor core are presented

  18. Comparison of procedures for immediate reconstruction of large osseous defects resulting from removal of a single tooth to prepare for insertion of an endosseous implant after healing

    NARCIS (Netherlands)

    Raghoebar, G. M.; Slater, J. J. H.; den Hartog, L.; Meijer, H. J. A.; Vissink, A.

    This study evaluated the treatment outcome of immediate reconstruction of 45 large osseous defects resulting from removal of a single tooth with a 1:2 mixture of Bio-Oss(R) and autologous tuberosity bone, and three different procedures for soft tissue closing (Bio-Gide(R) membrane, connective tissue

  19. [How to choose appropriate surgical approach in removal of the eyeball].

    Science.gov (United States)

    Ye, Juan; Ning, Qingyao

    2014-08-01

    We often consult patients with non-functional eye caused by trauma, intraocular malignancy, absolute stage of glaucoma and other diseases who need to remove the eyeball in our clinical work. Eye removal is an irreversibly destructive procedure, which mainly include enucleation and evisceration. There are various surgical techniques which are still controversial. Both of the two procedures have their own advantages, disadvantages, indications and contraindications. The ophthalmologists should comprehensively consider the disease situations, medical conditions and the requirements of the patients when choosing appropriate surgical approach to remove the eyeball.

  20. 12 CFR 19.243 - Removal, suspension, or debarment.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Removal, suspension, or debarment. 19.243 Section 19.243 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY RULES OF PRACTICE AND PROCEDURE Removal, Suspension, and Debarment of Accountants From Performing Audit Services § 19...

  1. [Surgical procedures involved in claims for alleged defects in praxis].

    Science.gov (United States)

    Arimany-Manso, Josep; Benet-Travé, J; Bruguera-Cortada, M; Torné-Escasany, R; Klamburg-Pujol, J; Gómez-Durán, Esperanza L

    2014-03-01

    Medical professional liability and adverse events in health care are major concerns worldwide and the analysis of claims for alleged defects in praxis is a potential source of knowledge. High rates of adverse events and complaints have been reported in surgical procedures. This article analyzes the claims registered by the Council of Medical Colleges in Catalonia between 1986 and 2012, and explores surgical procedures claimed (ICD- 9-CM coding), as well as the final outcome of the claim. Among the 5,419 records identified on surgical procedures, the interventions of the musculoskeletal system and skin and integument showed the highest frequencies. Interventions related to "non-curative" medicine should be emphasized because of their higher rates of economical agreement or condemnation outcomes, which were significantly higher for mastopexia. The results underscore the importance of the surgical area in medical professional liability and the high risk of payouts among those procedures belonging to the so-called "non-curative" medicine. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  2. Surgical strategy for malignant gliomas involving pyramidal tracts guided by functional neuronavigation and 5-ALA fluorescence navigation

    International Nuclear Information System (INIS)

    Sato, Ken-ichi; Ito, Tamio; Seo, Yoshinobu; Sunohara, Tadashi; Maeda, Masana; Sasaki, Takehiko; Nakagawara, Jyoji; Nakamura, Hirohiko

    2009-01-01

    For patients with malignant glioma invading pyramidal tracts, maximal resections are difficult to accomplish while preserving their motor function. We used tractography-integrated functional neuronavigation and 5-aminolevulinic acid (5-ALA) fluorescence-guided resection for removal of malignant gliomas involving pyramidal tract. In this study, we analyzed postoperative motor function and extent of resection in a series of patients who underwent surgery in our department. Ten patients with malignant glioma invading pyramidal tracts underwent radical surgery. To preserve pyramidal tracts, we developed a functional neuronavigation-guided fence-post procedure to avoid the problem of brain shift, a disadvantage of the existing neuronavigation systems. Furthermore we have achieved precise resection of tumors using 5-ALA fluorescence navigation. Intraoperatively, tumor fluorescence was visualized using a modified operating microscope. All fluorescing tumor tissue was resected. Motor function was preserved after appropriate tumor resection in all cases. Postoperatively, improvement of motor weakness was observed in seven patients, whereas transient mild motor weakness occurred in two patients. Gross total removals were accomplished in seven patients, and subtotal removal was accomplished in one patient, and partial removal was accomplished in two patients. Combined use of tractography-integrated functional neuronavigation and 5-ALA fluorescence-guided resection contributes to maximal safe resection of malignant gliomas with pyramidal tract involvement. (author)

  3. Image-guided percutaneous removal of ballistic foreign bodies secondary to air gun injuries.

    Science.gov (United States)

    Rothermund, Jacob L; Rabe, Andrew J; Zumberge, Nicholas A; Murakami, James W; Warren, Patrick S; Hogan, Mark J

    2018-01-01

    Ballistic injuries with retained foreign bodies from air guns is a relatively common problem, particularly in children and adolescents. If not removed in a timely fashion, the foreign bodies can result in complications, including pain and infection. Diagnostic methods to identify the presence of the foreign body run the entire gamut of radiology, particularly radiography, ultrasound (US) and computed tomography (CT). Removal of the foreign bodies can be performed by primary care, emergency, surgical, and radiologic clinicians, with or without imaging guidance. To evaluate the modalities of radiologic detection and the experience of image-guided ballistic foreign body removal related to air gun injuries within the interventional radiology department of a large pediatric hospital. A database of more than 1,000 foreign bodies that were removed with imaging guidance by the interventional radiologists at our institution was searched for ballistic foreign bodies from air guns. The location, dimensions, diagnostic modality, duration, complications and imaging modality used for removal were recorded. In addition, the use of sedation and anesthesia required for the procedures was also recorded. Sixty-one patients with ballistic foreign bodies were identified. All foreign bodies were metallic BBs or pellets. The age of the patients ranged from 5 to 20 years. The initial diagnostic modality to detect the foreign bodies was primarily radiography. The primary modality to assist in removal was US, closely followed by fluoroscopy. For the procedure, 32.7% of the patients required some level of sedation. Only two patients had an active infection at the time of the removal. The foreign bodies were primarily in the soft tissues; however, successful removal was also performed from intraosseous, intraglandular and intratendinous locations. All cases resulted in successful removal without complications. Image-guided removal of ballistic foreign bodies secondary to air guns is a very

  4. Involvement of experts in nuclear licensing and supervisory procedures who are known for their critical attitude towards nuclear technology

    International Nuclear Information System (INIS)

    Schirp, W.

    1996-01-01

    The article discusses legal and procedural aspects in the context of expert opinions demanded by the supervisory and licensing authorities of nuclear power plants, and the role and activities of experts known for their critical approach to nuclear electricity generation. The aspects addressed are: Reasons to break the dominance of ''established'' experts who in general are members of the TUeV organisations (technical control boards), reasons for challenging motions such as suspicion of prejudice or insufficient expertise, order by the supervisory authority to take a ''dual approach'' and involve two experts for a task, as well as the relevant administrative and legal procedures. (orig./CB) [de

  5. New atraumatic easy removal technique for permanently cemented crown

    Directory of Open Access Journals (Sweden)

    Pravinkumar G Patil

    2012-01-01

    Full Text Available Removal of a permanently cemented crown or fixed partial denture is a cumbersome procedure for a prosthodontist, especially when there is no purchase point available to remove it. The technique described in this article consists of sectioning of a crown on facial surface followed by removal of the crown with orthodontic plier. This technique does not damage the gingival/periodontal tissues or underlying tooth structure as the crown need not to be removed with jerky back-action force.

  6. 21 CFR 606.100 - Standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ... units. (9) Procedures for investigating adverse donor and recipient reactions. (10) Storage temperatures... accurately relating the product(s) to the donor. (5) Blood collection procedure, including in-process precautions taken to measure accurately the quantity of blood removed from the donor. (6) Methods of component...

  7. FMRI evidence for the involvement of the procedural memory system in morphological processing of a second language.

    Directory of Open Access Journals (Sweden)

    Christos Pliatsikas

    Full Text Available Behavioural evidence suggests that English regular past tense forms are automatically decomposed into their stem and affix (played  = play+ed based on an implicit linguistic rule, which does not apply to the idiosyncratically formed irregular forms (kept. Additionally, regular, but not irregular inflections, are thought to be processed through the procedural memory system (left inferior frontal gyrus, basal ganglia, cerebellum. It has been suggested that this distinction does not to apply to second language (L2 learners of English; however, this has not been tested at the brain level. This fMRI study used a masked-priming task with regular and irregular prime-target pairs (played-play/kept-keep to investigate morphological processing in native and highly proficient late L2 English speakers. No between-groups differences were revealed. Compared to irregular pairs, regular pairs activated the pars opercularis, bilateral caudate nucleus and the right cerebellum, which are part of the procedural memory network and have been connected with the processing of morphologically complex forms. Our study is the first to provide evidence for native-like involvement of the procedural memory system in processing of regular past tense by late L2 learners of English.

  8. Sphincter-saving reconstruction for radiation-injured rectum. A report of four cases with special reference to the pull-through procedure

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Yasuo; Moriya, Yoshihiro; Hojo, Keiichi (National Cancer Center, Tokyo (Japan). Hospital)

    1982-12-01

    Up to now sigmoid colostomy has been a widely accepted and conventional treatment for the radiation-injured rectum, but patients without residual malignancy strongly desire to live without a colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, the pull-through procedure was the most adequate. Provided the following five conditions are fulfilled, the pull-through procedure should be considered for the severely radiation-injured rectum. (1) No recurrence of the initial malignancy in the pelvis. (2) Preferably, a more than 2 cm intact rectal segment above the dentate line preserved. (3) No radiation-injured segment in the upper sigmoid. (4) No severe radiation damage in the small intestine. (5) Normal anal function.

  9. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  10. Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    Science.gov (United States)

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori; Tsuchida, Akihiko

    2011-01-01

    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 ± 71.5 d vs 166.2 ± 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. PMID:21677835

  11. Removal of a submandibular duct calculus with 'SNU Sialoop': Technical report

    International Nuclear Information System (INIS)

    Choi, Habg Moon; Lee, Sun Bok; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won

    2000-01-01

    Manufacturing method and technical procedure of 'SNU Sialoop', which was a new device designed for removal of sialolith, were introduced. Two cases about removal of Wharton' duct sialolith using SNU Sialoop were presented.

  12. Simple Technique for Removing Broken Pedicular Screws

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2014-03-01

    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  13. Surgical aspects of removal of Essure microinsert.

    Science.gov (United States)

    Albright, Catherine M; Frishman, Gary N; Bhagavath, Bala

    2013-09-01

    Essure is designed as a hysteroscopically placed permanent birth control. Removal of the Essure microinsert can be a technically challenging procedure. Requests for removal are uncommon but do occur. Although hysteroscopic and laparoscopic removal has been reported, there is limited information available describing appropriate surgical technique. There have been six patients requesting Essure removal at our institution (one approximately 2 years after placement). Based on this experience, we have developed specific counseling points and surgical principles for laparoscopic removal: avoid injection of a hemostatic solution into the fallopian tube; avoid excessive traction on the coils; avoid cauterization of the outer coil; follow the Essure coil into the interstitial end of the fallopian tube to ensure complete removal of the insert; perform a salpingectomy rather than a salpingostomy. By taking into account these principles, key preoperative counseling points can be discussed, and laparoscopic Essure removal years after placement can be accomplished in a safe and deliberate fashion. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Maxillary Swing Approach for Removal of Palatal Carcinoma: A Modified Procedure

    Directory of Open Access Journals (Sweden)

    Tsutomu Nomura

    2018-01-01

    Full Text Available Introduction. We report a modification of the maxillary swing approach to remove a palatal tumor while preserving the anterior alveolar area. Methods. Case report using clinical records. Results. The patient was a 54-year-old male. TNM grade was T4bN0M0, and invasion to the base of the pterygoid process was seen. Two courses of induction chemotherapy were administered prior to the operation. Because there was no evidence of anterior maxillary invasion, the maxillary swing approach was chosen. The left anterior maxilla was cut and swung laterally, preserving the blood supply. After removal of the palatal tumor, the maxilla was repositioned and the defect was restored with an anterior lateral thigh flap. Postoperative course was typical, and facial appearance, speech, and masticatory function were satisfactory. Conclusions. This technique is particularly useful for preserving appearance as well as speech and mastication.

  15. Membrane adsorber for endotoxin removal

    Directory of Open Access Journals (Sweden)

    Karina Moita de Almeida

    Full Text Available ABSTRACT The surface of flat-sheet nylon membranes was modified using bisoxirane as the spacer and polyvinyl alcohol as the coating polymer. The amino acid histidine was explored as a ligand for endotoxins, aiming at its application for endotoxin removal from aqueous solutions. Characterization of the membrane adsorber, analysis of the depyrogenation procedures and the evaluation of endotoxin removal efficiency in static mode are discussed. Ligand density of the membranes was around 7 mg/g dry membrane, allowing removal of up to 65% of the endotoxins. The performance of the membrane adsorber prepared using nylon coated with polyvinyl alcohol and containing histidine as the ligand proved superior to other membrane adsorbers reported in the literature. The lack of endotoxin adsorption on nylon membranes without histidine confirmed that endotoxin removal was due to the presence of the ligand at the membrane surface. Modified membranes were highly stable, exhibiting a lifespan of approximately thirty months.

  16. Performance and mechanism of simultaneous removal of Cd(II) and Congo red from aqueous solution by hierarchical vaterite spherulites

    Science.gov (United States)

    Chen, Yuan-Yuan; Yu, Sheng-Hui; Jiang, Hao-Fan; Yao, Qi-Zhi; Fu, Sheng-Quan; Zhou, Gen-Tao

    2018-06-01

    Hierarchical vaterite spherulites, synthesized by a simple injection-precipitation method at room temperature, were applied for the simultaneous removal of heavy metal Cd(II) and dye Congo red (CR) from aqueous solution. Batch experiments reveal that the maximum removal capacities of as-prepared vaterite spherulites to Cd(II) and CR are 984.5 and 89.0 mg/g, respectively, showing excellent removal performance for Cd(II) and CR. Furthermore, in the binary Cd(II)-CR system, the removal capacity of vaterite to Cd(II) is significantly enhanced at lower CR concentration (100 mg/L). In contrast, the concurrent Cd(II) shows negligible effect on the CR removal. The simultaneous removal mechanism was investigated by FESEM, EDX, XRD, FT-IR and XPS techniques. The simultaneous removal of Cd(II) and CR in the binary system is shown to be a multistep process, involving the preferential adsorption of dye CR, stabilization of CR to vaterite, coordination of the adsorbed CR molecules with Cd(II), and transformation of vaterite into otavite. Given the facile and green synthesis procedure, and effective removal of Cd(II) and CR in the binary system, the obtained vaterite spherulites have considerable practical interest in integrative treatment of wastewater contaminated by heavy metals and dyes.

  17. [Fluorescence control of dental calculus removal].

    Science.gov (United States)

    Bakhmutov, D N; Gonchukov, S A; Lonkina, T V; Sukhinina, A V

    2012-01-01

    The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In the frames of this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise detection of tooth-calculus interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing (as ultrasonic or laser devices).

  18. Factory Acceptance Test Procedure Westinghouse 100 ton Hydraulic Trailer

    International Nuclear Information System (INIS)

    Aftanas, B.L.

    1994-01-01

    This Factory Acceptance Test Procedure (FAT) is for the Westinghouse 100 Ton Hydraulic Trailer. The trailer will be used for the removal of the 101-SY pump. This procedure includes: safety check and safety procedures; pre-operation check out; startup; leveling trailer; functional/proofload test; proofload testing; and rolling load test

  19. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-24

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the removal action project at the former YS-860 Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead-contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects.

  20. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-01-01

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the removal action project at the former YS-860 Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead-contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects

  1. Thermally modified bentonite clay for copper removal

    International Nuclear Information System (INIS)

    Bertagnolli, C.; Kleinübing, S.J.; Silva, M.G.C.

    2011-01-01

    Bentonite clay coming from Pernambuco was thermally modified in order to increase its affinity and capacity in the copper removal in porous bed. The application of this procedure is justified by the low cost of clay, their abundance and affinity for various metal ions. Thermally treatment modifies the clay adsorption properties enables its use in porous bed system, with the increase in surface area and mechanical strength. The material was characterized by x-ray diffraction, thermogravimetric analysis and N_2 physisorption. Then tests were carried out for adsorption of copper in various experimental conditions and evaluated the mass transfer zone, useful and total adsorbed removal amounts and total copper removal percentage. The results showed that the clay treated at higher temperature showed higher copper removal. (author)

  2. Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases.

    Science.gov (United States)

    Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi

    2018-02-01

    Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.

  3. Surgical Eye Removal in Ile‑Ife, Nigeria

    African Journals Online (AJOL)

    Surgical eye removal procedures include evisceration, enucleation, and ... eliminate the risk of sympathetic ophthalmitis in ruptured globes, relieve ... cite this article: ***. This is an open access article distributed under the terms of the Creative.

  4. 12 CFR 308.604 - Notice of removal, suspension, or debarment.

    Science.gov (United States)

    2010-01-01

    ... issuance of a final order for removal, suspension, or debarment of an independent public accountant or..., whichever date is earlier. The written notice must be filed by the independent public accountant or... PRACTICE RULES OF PRACTICE AND PROCEDURE Removal, Suspension, and Debarment of Accountants From Performing...

  5. Feasibility Assessment of Cesium Removal using Microaglae

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ilgook; Ryu, Byung-Gon; Seo, Bum-Kyoung; Moon, Jei Kwon; Choi, Jong-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The aim of this work is to assess the feasibility of selected one of microalgae in the uptake of Cs+. The obtained results showed the maximum Cs+ removal by D. armatus SCK was 280μM indicating 70% removal efficiency. Also, D. armatus SCK could uptake Cs+ in the presence of K+, is particularly known to be transported into cells as an analog of Cs+ in freshwater condition. Recently, increased attention has been directed on the use of biological technologies for the removal of radionuclides as the cheap and eco-friendly alternative to the non-biological methods. Metal including radioactive compounds uptake by microorganisms can be occurred by metabolism –independent and/or -dependent processes. One involves biosorption based on the ability of microbial cells to bind dissolved metals; on the other involves bioaccumulation, which depends on the metabolic ability of cells to transport metals into the cytoplasm. The purpose of this work is to investigate the feasibility of microalgae in bioaccumulation system to remove cesium from solution. The effect of different environmental parameters on cesium removal was also examined.

  6. The role of appendectomy in surgical procedures for ovarian cancer.

    Science.gov (United States)

    Fontanelli, R; Paladini, D; Raspagliesi, F; di Re, E

    1992-07-01

    To assess the role of appendectomy in the surgical procedures for ovarian cancer, we evaluated retrospectively the clinical charts of 435 patients who underwent surgery after diagnosis of ovarian cancer. The appendix was removed in 160 cases and pathological examination revealed 37 with metastatic implants (23%). All the patients with appendiceal metastases showed advanced disease (stages III-IV) with an incidence of 43%. Ninety-one percent (31/34) of the tumors with appendiceal involvement at the staging operation were of the serous cell type and grade II or III. No case with early stage, right ovary carcinoma showed appendiceal metastatic foci, denying the existence of a preferential lymphatic pathway. Microscopic involvement was found only in 4 patients with advanced disease (11.7%). No intra- or postoperative complication directly related to the appendectomy was recorded. We conclude, with these results, that appendectomy should be part of the cytoreductive operation for ovarian cancer.

  7. Determinants of procedural pain intensity in the intensive care unit. The Europain® study

    DEFF Research Database (Denmark)

    Puntillo, Kathleen A; Max, Adeline; Timsit, Jean-Francois

    2014-01-01

    in 192 ICUs in 28 countries. MEASUREMENTS AND MAIN RESULTS: Pain intensity on a 0-10 numeric rating scale increased significantly from baseline pain during all procedures (P tube removal, wound drain removal, and arterial line insertion were the three most painful procedures, with median...

  8. Imaging of foreign bodies in the face and ultrasound guided surgical removal; Diagnostico por imagem de corpos estranhos da face e retirada cirurgica guiada por ultra-sonografia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Claudio Marcio Amaral de Oliveira; Gambin, Moises; Ribeiro, Erica Barreiros; Amarante Junior, Jose Luiz de Medeiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil)]. E-mail: cmaol@br.inter.net; cmaolima@hotmail.com; Monteiro, Alexandra Maria Vieira [Pontificia Univ. Catolica do Rio de Janeiro (PUC/Rio), RJ (Brazil). Curso de Pos-Graduacao em Radiologia

    2006-10-15

    The identification and surgical removal of foreign bodies is a complex procedure in medical practice, principally when the involved material is radiolucent. The technological advent of the ultrasonography equipment comes enlarging the field of application of this method more and more, in medical practice. The authors describe a case of an ultrasound guided surgical removal of glass fragments from the face of a patient. The foreign bodies were previously diagnosed by ultrasound and computed tomography. The guided technic showed secure, less invasive and efficient, allowing the retreat of all the fragments. (author)

  9. 12 CFR 19.245 - Notice of removal, suspension or debarment.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Notice of removal, suspension or debarment. 19.245 Section 19.245 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY RULES OF PRACTICE AND PROCEDURE Removal, Suspension, and Debarment of Accountants From Performing Audit Services...

  10. Developing a highway emergency response plan for incidents involving hazardous materials, second edition, March 1992

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This provides minimum guidelines for developing an emergency response plan for incidents involving hazardous liquid hydrocarbons, such as gasoline and crude oil, transported in MC 306/DOT 406 and MC 307/DOT 407 aluminum cargo tanks and for coordinating and cooperating with local, state, and federal officials. This publication covers response plan priorities, personnel training, special equipment, media relations, environmental relations, and post-response activities. The apprendixes to this recommended practice outline a highway emergency response plan and suggest a procedure for removing liquid hydrocarbons from overturned cargo tanks and righting the tank vehicles

  11. Methods of removing uranium from drinking water. 1. A literature survey. 2. Present municipal water treatment and potential removal methods

    International Nuclear Information System (INIS)

    Drury, J.S.; Michelson, D.; Ensminger, J.T.; Lee, S.Y.; White, S.K.

    1982-12-01

    Literature was searched for methods of removing uranium from drinking water. U.S. manufacturers and users of water-treatment equipment and products were also contacted regarding methods of removing uranium from potable water. Based on the results of these surveys, it was recommended that untreated, partially treated, and finished water samples from municipal water-treatment facilities be analyzed to determine the extent of removal of uranium by presently used procedures, and that additional laboratory studies be performed to determine what changes are needed to maximize the effectiveness of treatments that are already in use in existing water-treatment plants

  12. 5 CFR 9701.707 - Appeals of mandatory removal actions.

    Science.gov (United States)

    2010-01-01

    ... employee may appeal such actions to the Mandatory Removal Panel (MRP) established under § 9701.708. (b) Procedures. (1) The MRP will establish procedures for the fair, impartial, and expeditious assignment and... other matters as may be necessary to ensure the operation of the MRP. (2) The MRP will conduct a hearing...

  13. Use of a powered shaver to remove multiple oral cavity papillomas.

    Science.gov (United States)

    Miller, Robert Sean; Tami, Thomas A

    2005-05-01

    We report a previously undescribed method of removing multiple oral papillomas, which we performed on 5 men with human immunodeficiency virus (HIV) infection. Patients were brought to the operating room and placed under general anesthesia. In addition, 1% lidocaine with 1:100,000 epinephrine was injected under and around the lesions. We then removed the lesions with a Tricut laryngeal blade attached to a handheld powered shaver Postoperatively, patients were sent home on clindamycin, a pain medication, and Peridex. At the 1-week follow-up, patients reported only minimal pain, and their wounds were well healed. We observed no adverse events associated with the shaving procedure. Our method expedites the process of removing multiple oral cavity papillomas while reducing the morbidity generally associated with other procedures.

  14. Tackling the challenge of selective analytical clean-up of complex natural extracts: the curious case of chlorophyll removal.

    Science.gov (United States)

    Bijttebier, Sebastiaan; D'Hondt, Els; Noten, Bart; Hermans, Nina; Apers, Sandra; Voorspoels, Stefan

    2014-11-15

    Alkaline saponification is often used to remove interfering chlorophylls and lipids during carotenoids analysis. However, saponification also hydrolyses esterified carotenoids and is known to induce artifacts. To avoid carotenoid artifact formation during saponification, Larsen and Christensen (2005) developed a gentler and simpler analytical clean-up procedure involving the use of a strong basic resin (Ambersep 900 OH). They hypothesised a saponification mechanism based on their Liquid Chromatography-Photodiode Array (LC-PDA) data. In the present study, we show with LC-PDA-accurate mass-Mass Spectrometry that the main chlorophyll removal mechanism is not based on saponification, apolar adsorption or anion exchange, but most probably an adsorption mechanism caused by H-bonds and dipole-dipole interactions. We showed experimentally that esterified carotenoids and glycerolipids were not removed, indicating a much more selective mechanism than initially hypothesised. This opens new research opportunities towards a much wider scope of applications (e.g. the refinement of oils rich in phytochemical content). Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Effect of scleral buckle removal on strabismus surgery outcomes after retinal detachment repair

    Science.gov (United States)

    Chang, Jee Ho; Hutchinson, Amy; Zhang, Monica; Lambert, Scott R.

    2015-01-01

    Background/Aims To investigate the effect of scleral buckle removal on the outcomes of strabismus surgery in patients with a prior history of retinal detachment surgery. Methods We reviewed the medical records of 18 patients who underwent strabismus surgery following a scleral buckling procedure at one institution. We investigated the effect of multiple variables on outcome, including: gender, age, surgeon, number of strabismus surgeries, adjustable suture use, previous pars plana vitrectomy, preoperative best-corrected visual acuity and time of surgery. Outcomes were considered successful if there was ≤ 10 prism diopter (PD) residual horizontal and/or ≤ 4 PD residual vertical deviation. Outcomes were analyzed statistically using Fisher's exact test and Mann-Whitney test. Results Strabismus surgery coupled with scleral buckle removal was associated with a higher rate of success (success with buckle removal, 62.5%; success without buckle removal, 10.0%; p=0.04). There were no significant difference in preoperative findings between the scleral buckle removal and non- removal groups. No retinal redetachments occurred after scleral buckle removal. Conclusion In our series, scleral buckle removal was associated with improved surgical outcome in patients with strabismus following a scleral buckling procedure. PMID:24299332

  16. One-stage surgery for removal of intravascular leiomyomatosis extending to right ventricle.

    Science.gov (United States)

    Chiang, Ching-Shu; Chen, Po-Lin; Kuo, Tzu-Ting; Chen, I-Ming; Wu, Nai-Yuan; Chang, Hsiao-Huang

    2018-03-01

    Intravascular leiomyomatosis (IVL) is a rare nonmalignant tumor that can be fatal if untreated. A 49-year-old nulliparous Asian woman who underwent hysterectomy and left salpingo-oophorectomy for multiple uterine leiomyomas 18 months prior presented complaining of intermittent palpitation and chest tightness for approximately 1 month. Echocardiography revealed a large mobile tumor mass extending from the inferior vena cava (IVC) to the right atrium that partially obstructed IVC flow and tricuspid inflow. Thoracicabdominopelvic computed tomography revealed a left adnexal tumor (4.8 × 2.5 cm) causing intravascular obstruction extending from the left internal iliac vein to the IVC, right atrium, and right ventricle. IVL with right heart involvement INTERVENTIONS:: Under cardiopulmonary bypass, a one-stage surgery combining sternotomy and laparotomy was performed. The tumor was approached and extracted via sternotomy, and tumor detachment and removal of residual tumors was accomplished via laparotomy. A firm, smooth, and regularly shape tumor 15.5 × 5.5 × 2.5 in size was completely removed and histopathologically confirmed as IVL. The patient tolerated the surgical procedure well and no postoperative complication was noted. We describe a one-stage surgical approach to completely remove an IVL extending to the right ventricle.

  17. 77 FR 76861 - Removal of Job Training Partnership Act Implementing Regulations

    Science.gov (United States)

    2012-12-31

    ..., 633, 634, 636, 637, and 638 RIN 1205-AB68 Removal of Job Training Partnership Act Implementing...=FR . SUPPLEMENTARY INFORMATION: I. Direct Final Rule Procedure Since removal of the Job Training... barriers to employment for participation in the labor force by providing job training and other services...

  18. The influence of steam cleaning procedures on the surface roughness of commonly used type III dental stone for the fabrication of removable dentures.

    Science.gov (United States)

    Cilingir, Altug; Geckili, Onur; Parlar, Zeynep; Gencel, Burc; Bozdag, Ergun; Temiz, Vedat

    2013-09-01

    This study investigated the possible detrimental effects of steam treatment on the surface of type III dental stone, which is a common laboratory material used for the construction of removable dentures. Forty dental stone specimens were prepared and divided into four groups (A, B, C and D), and group A was used as the control group. The other groups were treated with steam from a standard distance for varying durations (30, 60 and 120 s). The duration of steam cleaning significantly increased Ra values (F = 63.150, p = 0.000). Similarly, the duration of steam application was directly correlated with the weight changes (F = 17.721, p = 0.000). A significant amount of dental stone can be removed from the surface while treating with steam. These studies demonstrated that expanded periods of steam cleaning cause weight loss and abrade the surface of type III dental stones; therefore, these devices should be used with caution during denture fabrication procedures. © 2012 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  19. Disassembly and removal of sodium instrumentation test loop

    International Nuclear Information System (INIS)

    Ishikawa, Okinobu; Onojima, Takamitu; Nagai, Keiichi

    2000-07-01

    In 1999, the Sodium Instrumentation Test Loop was disassembled and removed. This report describes the tasks and experiences obtained in removing sodium from a storage tank, disassembling, and cleansing components and related activities. Overall the disassembly, handling and cleansing tasks proceeded as planned and the activities were carried out efficiently and safely. Documentation of the process is meant to establish not only a procedure, but also a guideline for future similar tasks. (author)

  20. Analytical Chemistry Laboratory (ACL) procedure compendium

    International Nuclear Information System (INIS)

    1993-01-01

    This volume contains the interim change notice for the safety operation procedure for hot cell. It covers the master-slave manipulators, dry waste removal, cell transfers, hoists, cask handling, liquid waste system, and physical characterization of fluids

  1. Removing Bureaucracy

    Science.gov (United States)

    2015-08-01

    11 Defense AT&L: July–August 2015 Removing Bureaucracy Katharina G. McFarland McFarland is Assistant Secretary of Defense for Acquisition. I once...involvement from all of the Service warfighting areas came together to scrub the program requirements due to concern over the “ bureaucracy ” and... Bureaucracy ” that focuses on reducing cycle time, staffing time and all forms of inefficiencies. This includes review of those burdens that Congress

  2. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  3. Mechanically controlled moisture removal from greenhouses

    NARCIS (Netherlands)

    Campen, J.B.; Kempkes, F.L.K.; Bot, G.P.A.

    2009-01-01

    The object of this study was to design and test a system capable of dehumidifying air in a greenhouse when a thermal screen is in use. Dehumidification is required to reduce the risk of fungal diseases and prevent physiological disorders. The most common procedure used to remove moisture from a

  4. Chromaticity based smoke removal in endoscopic images

    Science.gov (United States)

    Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail

    2017-02-01

    In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.

  5. Effects of various uranium leaching procedures on soil: Short-term vegetation growth and physiology. Progress report, April 1994

    International Nuclear Information System (INIS)

    Edwards, N.T.

    1994-08-01

    Significant volumes of soil containing elevated levels of uranium exist in the eastern United States. The contamination resulted from the development of the nuclear industry in the United States requiring a large variety of uranium products. The contaminated soil poses a collection and disposal problem of a magnitude that justifies the development of decontamination methods. Consequently, the Department of Energy (DOE) Office of Technology Development formed the Uranium Soils Integrated Demonstration (USID) program to address the problem. The fundamental goal of the USID task group has been the selective extraction/leaching or removal of uranium from soil faster, cheaper, and safer than what can be done using current conventional technologies. The objective is to selectively remove uranium from soil without seriously degrading the soil's physicochemical characteristics and without generating waste that is difficult to manage and/or dispose of. However, procedures developed for removing uranium from contaminated soil have involved harsh chemical treatments that affect the physicochemical properties of the soil. The questions are (1) are the changes in soil properties severe enough to destroy the soil's capacity to support and sustain vegetation growth and survival? and (2) what amendments might be made to the leached soil to return it to a reasonable vegetation production capacity? This study examines the vegetation-support capacity of soil that had been chemically leached to remove uranium. The approach is to conduct short-term germination and phytotoxicity tests for evaluating soils after they are subjected to various leaching procedures followed by longer term pot studies on successfully leached soils that show the greatest capacity to support plant growth. This report details the results from germination and short-term phytotoxicity testing of soils that underwent a variety of leaching procedures at the bench scale at ORNL and at the pilot plant at Fernald

  6. Improvements in Logic Diagram of Computerized Procedure System of APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sungkweon; Seong, Nokyu [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The Computerized Procedure System (CPS) has been improved since it is installed in Shin-Kori 3 and 4 Nuclear Power Plants. It is one of operating support systems of digital Main Control Room (MCR) and provides many functions to operators in executing the procedure. CPS can effectively remove the human errors by supporting the procedure flow and logic diagram. This paper describes the logic diagram of CPS of reference power plant and shows the improved logic diagram of CPS of Shin-Kori unit 5 and 6. This paper describes the current logic diagram of CPS and suggests improved design for logic diagram. The improved logic diagram shall be validated through human factors engineering verification and validation. The improved design will help operators execute the computerized procedure fast and remove the human error.

  7. Ultrasound guided percutaneous removal of wooden foreign bodies in the extremities with hydro-dissection technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, HeeJin; Lee, So Yeon; Chung, Eun Chul; Rho, Myung Ho [Dept. of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Lee, Sung Moon; Son, Eun Seok [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Sun Joo [Dept. of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of)

    2015-12-15

    We described the technique of ultrasound (US)-guided percutaneous removal of the foreign bodies (FB) with hydro-dissection in the radiologic department and presented video files of several cases.Four patients referred to the radiology department for US evaluation and US-guided percutaneous removal of the FBs in the upper and lower extremities between November, 2006 and November, 2013 were included in this study. The procedures started with US evaluation for the exact location and shape of the FB. A 5 mm-sized skin incision was made at the site of the nearest point from the FB where no passing arteries or tendons were present. We adopted a hydro dissection technique to separate the FB from adjacent tissue using a 2% lidocaine solution. Injected anesthetics detached the FBs from surrounding tissue and thereby facilitated removal. After the tip of the mosquito forceps reached the FB, the wooden FBs were removed. The mean time required for the entire procedure was approximately 20 minutes. There were no significant complications during the US-guided removal or long-term complications after the procedure. All 4 FBs were successfully removed from the soft tissue under US guidance. Ultrasound-guided percutaneous removal of the FBs with hydro-dissection in the radiology department is a less invasive and safe method over surgical removal in the operating room. Additionally, the use of a guide wire and serial dilator may help minimize soft tissue injury and facilitate the introduction of forceps.

  8. Hardware-related infections after deep brain stimulation surgery: review of incidence, severity and management in 212 single-center procedures in the first year after implantation.

    Science.gov (United States)

    Piacentino, Massimo; Pilleri, Manuela; Bartolomei, Luigi

    2011-12-01

    Device-related infection is a common occurrence after deep brain stimulation (DBS) surgery, and may result in additional interventions and a loss of efficacy of therapy. This retrospective review aimed to evaluate the incidence, severity and management of device-related infections in 212 DBS procedures performed in our institute. Data on 106 patients, in whom 212 DBS procedures were performed between 2001 and 2011 at our institute by a single neurosurgeon (M.P.), were reviewed to assess the incidence, severity, management and clinical characteristics of infections in the first year after the implantation of a DBS system. Infections occurred in 8.5% of patients and 4.2% of procedures. Of the nine infections, eight involved the neurostimulator and extensions, and one the whole system. The infections occurred 30.7 days after implantation: 7 within 30 days and 2 within 6 months. Infected and uninfected patients were comparable in terms of age, sex, indication for DBS implantation and neurostimulator location. In eight cases, the system components involved were removed and re-implanted after 3 months, while in one case the complete hardware was removed and not re-implanted. The overall incidence of postoperative infections after DBS system implantation was 4.2%; this rate decreased over time. All infections required further surgery. Correct and timely management of partial infections may result in successful salvage of part of the system.

  9. Optimising laser tattoo removal

    Directory of Open Access Journals (Sweden)

    Kabir Sardana

    2015-01-01

    Full Text Available Lasers are the standard modality for tattoo removal. Though there are various factors that determine the results, we have divided them into three logical headings, laser dependant factors such as type of laser and beam modifications, tattoo dependent factors like size and depth, colour of pigment and lastly host dependent factors, which includes primarily the presence of a robust immune response. Modifications in the existing techniques may help in better clinical outcome with minimal risk of complications. This article provides an insight into some of these techniques along with a detailed account of the factors involved in tattoo removal.

  10. Optimising Laser Tattoo Removal

    Science.gov (United States)

    Sardana, Kabir; Ranjan, Rashmi; Ghunawat, Sneha

    2015-01-01

    Lasers are the standard modality for tattoo removal. Though there are various factors that determine the results, we have divided them into three logical headings, laser dependant factors such as type of laser and beam modifications, tattoo dependent factors like size and depth, colour of pigment and lastly host dependent factors, which includes primarily the presence of a robust immune response. Modifications in the existing techniques may help in better clinical outcome with minimal risk of complications. This article provides an insight into some of these techniques along with a detailed account of the factors involved in tattoo removal. PMID:25949018

  11. Procedure to remove dissolved nickel and/or radium compounds from water and facility therefor

    International Nuclear Information System (INIS)

    Moravec, J.

    2004-01-01

    Dissolved nickel and/or radium compounds are removed from water on a granular material such as quartz sand, crushed coal or granulated MnO 2 whose surface contains oxides of manganese MnO x . The compounds to be removed are adsorbed into the MnO x layer. Subsequently the adsorbed compounds are desorbed with a reductant, such as sodium sulfite, which is present in a concentration forming a redox potential of -5 to -120 mV, and with a solution of sodium polyphosphate, such as sodium hexametaphosphate (NaPO 3 ) n . Two variants are possible: either MnO x is first acted upon with the reductant and subsequently with the polyphosphate, or a mixed solution of the two agents is used. The excess of the agents is removed with water or with a KMnO 4 solution at 0.001 to 25 g/L. The granular material as well as the agent solutions (after concentration) are reusable. (P.A.)

  12. Techniques for removing contaminants from optical surfaces

    International Nuclear Information System (INIS)

    Stowers, I.F.; Patton, H.G.

    1978-01-01

    Particle removal procedures such as plasma cleaning, ultrasonic agitation of solvents, detergents, solvent wiping, mild abrasives, vapor degreasing, high pressure solvent spraying and others have been evaluated and the results are reported here. Wiping with a lens tissue wetted with an organic solvent and high pressure fluid spraying are the only methods by which particles as small as 5 μm can be effectively removed. All of the other methods tested were found to be at least two orders of magnitude less effective at removing small insoluble particles. An additional and as yet unresolved problem is the development of a reliable method for evaluating particulate surface cleanliness. Without such a reproducible monitoring technique, the large diversity of cleaning methods currently available cannot be quantitatively evaluated

  13. Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy

    Directory of Open Access Journals (Sweden)

    Fruchter Oren

    2010-09-01

    Full Text Available Abstract Background Airway complications are among the most challenging problems after lung transplantation, and Self-Expandable Metallic Stents (SEMS are used to treat airway complications such as stenosis or malacia at the bronchial anastomosis sites. Several transplantation centers are reluctant to use SEMS since their removal is sometimes needed and usually requires the use of rigid bronchoscopy under general anesthesia. The objective of the current report is to describe our experience in SEMS retrieval by flexible bronchoscopy under conscious sedation. Methods A retrospective review was done of patients requiring tracheobronchial stent placement after lung transplantation in which the SEMS had to be removed. The retrieval procedure was done by flexible bronchoscopy on a day-care ambulatory basis. Results Between January 2004 and January 2010, out of 305 lung transplantation patients, 24 (7.8% underwent SEMS placement. Indications included bronchial stenosis in 20 and bronchomalacia in 4. In six patients (25% the SEMS had to be removed due to excessive granulation tissue formation and stent obstruction. The average time from SEMS placement to retrieval was 30 months (range 16-48 months. The stent was completely removed in five patients and partially removed in one patient; no major complications were encountered, and all patients were discharged within 3 hours of the procedure. In all procedures, new SEMS was successfully re-inserted thereafter. Conclusions The retrieval of SEMS in patients that underwent lung transplantation can be effectively and safely done under conscious sedation using flexible bronchoscopy on a day-care basis, this observation should encourage increasing usage of SEMS in highly selected patients.

  14. Superfund TIO videos. Set A. Identifying PRPS. Removal process: Removal site evaluation. Part 2. Audio-Visual

    International Nuclear Information System (INIS)

    1990-01-01

    The videotape is divided into three sections. Section 1 details the liability of Potentially Responsible Parties (PRPs) and describes the four classes of PRPs: current owners and operators, former owners and operators, generators, and transporters (if they selected the site). Section 2 lists the goals of the Potentially Responsible Party (PRP) search and explains how to identify key players during the PRP search. How to plan and conduct the PRP search is also outlined. Section 3 outlines the steps involved in conducting a removal site evaluation. A discussion of when to conduct a removal preliminary assessment, a removal site inspection, and an Engineering Evaluation/Cost Analysis (EE/AC) also is covered

  15. 28 CFR 523.17 - Procedures.

    Science.gov (United States)

    2010-07-01

    ..., unless the reason for transfer would otherwise have caused removal from an earning status, and provided... status if not immediately employed in Federal Prison Industries or assigned to a work/study release... comply with procedures outlined in § 523.11. (f) An inmate serving a life sentence may earn extra good...

  16. A Safe Protocol for Amalgam Removal

    Directory of Open Access Journals (Sweden)

    Dana G. Colson

    2012-01-01

    Full Text Available Today's environment has different impacts on our body than previous generations. Heavy metals are a growing concern in medicine. Doctors and individuals request the removal of their amalgam (silver mercury restorations due to the high mercury content. A safe protocol to replace the silver mercury filling will ensure that there is minimal if any absorption of materials while being removed. Strong alternative white composite and lab-processed materials are available today to create a healthy and functioning mouth. Preparation of the patient prior to the procedure and after treatment is vital to establish the excretion of the mercury from the body.

  17. Removal of a fractured needle during inferior alveolar nerve block: two case reports.

    Science.gov (United States)

    You, Jae-Seek; Kim, Su-Gwan; Oh, Ji-Su; Choi, Hae-In; Jih, Myeong-Kwan

    2017-09-01

    The inferior alveolar nerve block is the most common method of local anesthesia for intraoral surgery at the posterior mandibular region. However, unexpected complications may occur when administering the local anesthesia. One of these uncommon complications is the fracture of the needle. If the injection needle is broken during the surgery, it should be removed immediately. However, this is one of the most difficult procedures. In this report, we present two cases of needle fracture during the procedure, and its successful removal under general/local anesthesia administration.

  18. Toddler test or procedure preparation

    Science.gov (United States)

    ... a test or procedure: Explain the procedure in language your child understands, using plain words. Avoid abstract terms. Make sure your child understands the exact body part involved in the test, and that the ...

  19. Effect of biological and chemical oxidation on the removal of estrogenic compounds (NP and BPA) from wastewater: an integrated assessment procedure.

    Science.gov (United States)

    Bertanza, Giorgio; Pedrazzani, Roberta; Dal Grande, Mario; Papa, Matteo; Zambarda, Valerio; Montani, Claudia; Steimberg, Nathalie; Mazzoleni, Giovanna; Di Lorenzo, Diego

    2011-04-01

    A major source of the wide presence of EDCs (Endocrine Disrupting Compounds) in water bodies is represented by direct/indirect discharge of sewage. Recent scientific literature reports data about their trace concentration in water, sediments and aquatic organisms, as well as removal efficiencies of different wastewater treatment schemes. Despite the availability of a huge amount of data, some doubts still persist due to the difficulty in evaluating synergistic effects of trace pollutants in complex matrices. In this paper, an integrated assessment procedure was used, based on chemical and biological analyses, in order to compare the performance of two full scale biological wastewater treatment plants (either equipped with conventional settling tanks or with an ultrafiltration membrane unit) and tertiary ozonation (pilot scale). Nonylphenol and bisphenol A were chosen as model EDCs, together with the parent compounds mono- and di-ethoxylated nonylphenol (quantified by means of GC-MS). Water estrogenic activity was evaluated by applying the human breast cancer MCF-7 based reporter gene assay. Process parameters (e.g., sludge age, temperature) and conventional pollutants (e.g., COD, suspended solids) were also measured during monitoring campaigns. Conventional activated sludge achieved satisfactory removal of both analytes and estrogenicity. A further reduction of biological activity was exerted by MBR (Membrane Biological Reactor) as well as ozonation; the latter contributed also to decrease EDC concentrations. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Magnetic Stent Removal in a Nurse-Led Clinic; a Nine-Month Experience.

    LENUS (Irish Health Repository)

    O’Connell, L

    2018-02-01

    Ureteric stents are frequently inserted post endourological procedures. However, subsequent endoscopic stent removal requires a second procedure for the patient and the availability of necessary resources. Longer duration of indwelling stents can lead to increased risk of symptoms and complications. The use of magnetic stents removed with a magnetic retrieval device (BlackStar©), offers an alternative which obviates the need for cystoscopy. We assessed the outcomes for this novel method of stent removal in our institution. A retrospective analysis was performed of all patients undergoing magnetic stent insertion and subsequent removal in a nurse-led clinic over a nine-month period. Patients were followed up with a prospective validated Ureteral Stent Symptoms Questionnaire (USSQ)3. A cost analysis was also performed. In total, 59 patients were treated using magnetic stents. The complication rate was low (6.7%). The median duration of indwelling stent was 5.8 days (range 1-11 days). Patients reported haematuria and lower urinary tract symptoms but >90% experienced no functional impairment with minimal days of employment lost (mean 0.75 days). All patients reported satisfaction with nurse-led stent removal and 97% were happy to have stents removed via this method in the future. The total financial savings were estimated at €47,790 over this period. Nurse-led removal of magnetic stents is safe and well tolerated by patients and enables expedient stent removal. It also provides a significant cost benefit and frees up valuable endoscopic resources.

  1. Pollutants in drinking water - sources, harmful effects and removal procedures

    International Nuclear Information System (INIS)

    Qadeer, R.

    2005-01-01

    The underground water resources available for human consumption are being continuously contaminated by the natural sources and anthropogenic activities. The pollutants include toxic microorganism, inorganic and organic chemicals and radionuclide etc. This is an acute problem in our country, where free style way of disposal of industrial effluents into the natural water bodies contaminates the surface and ground water. These contaminants make their way into human body through contaminated drinking water, which leads to the malfunctioning of the body organs. Details of some pollutants present in drinking water, their source and harmful effects on human beings are reviewed in this communication Merits and demerits of methods used to remove the pollutants from drinking water are also discussed. (author)

  2. Residual heat removal during accidental situations

    International Nuclear Information System (INIS)

    Depond, M.; Sureau, H.; Tellier, N.

    1983-07-01

    Existing emergency procedures, whose purpose is residual heat removal and a safe recovery are based on sequential analysis and initiating event diagnosis. This approach was found in some cases inappropriate and inefficient, specially in case of out-of-design accidents corresponding to multiple equipment failure or simultaneous human failures. To cope with these situations, a new approach was necessary. Parallel studies performed in France at Framatome (the designer) and Electricity de France (the utility) gave a new method, called NSSS physical states approach. Prior to the implementation of this method which necessitates further studies and developments, some improvements in the existing operating procedures derived from the NSSS physical states have already been achieved: that is the case for the safety injection control and the development of an emergency procedure called ''U1''. This paper will briefly physical states approach and present the ''U1'' procedure. The tools which will be used to chack these methods are also mentioned

  3. Value of modified Foley catheter method in the removal of blunt esophageal foreign bodies

    International Nuclear Information System (INIS)

    Kim, Kyung In; Cha, Yoo Mi; Han, Heon; Yang, Dal Mo; Kim, Hyung Sik; Lee, Young Seok

    1993-01-01

    Removal of blunt esophageal foreign bodies using Foley catheter under a fluoroscopic guidance is a well recognized procedure. However, since this procedure is rather cumbersome and uncomfortable to the patient, the authors tried to find an easier and more convenient modified technique. For 10 patients with esophageal foreign body, we tried the method to the patient who is lying in the right lateral decubitus position and 3 assistants hold head, arms, trunk and legs of the patient without tilting the table and without using immobilizer. Foley catheter is inserted through nostril, nasal cavity and pharynx to esophagus. in order to identify the Foley catheter in esophagus, 0.025 inch short wire was inserted in the Foley catheter. The balloon of a Foley catheter was inflated by 10 cc of air, and the syringe was kept attached to the Foley catheter during the procedure. After passage of the foreign body through the upper esophageal sphinter, the balloon was deflated immediately and the foreign body was removed through the mouth. We successfully removed in removing all the blunt esophageal foreign body with ease. This modified method is also fast, safe and efficient

  4. Biotransformations Involved in Sustained Reductive Removal of Uranium in Contaminated Aquifers. Final report

    International Nuclear Information System (INIS)

    Lovley, Derek R.

    2008-01-01

    The studies completed under this grant significantly advanced the understanding and design of strategies for in situ uranium bioremediation. Novel strategies identified show promise to make in situ uranium bioremediation technically simpler and less expensive. As detailed, important findings included: (1) Development of an electron donor delivery strategy to prolong the in situ activity of Geobacter species and enhance the removal of uranium from the groundwater; (2) Demonstration that reproducible year-to-year field experiments were possible at the ERSP study site in Rifle, CO, making hypothesis-driven field experimentation possible; (3) Elucidation of the geochemical and microbiological heterogeneities with the subsurface during in situ uranium bioremediation, which must be accounted for to accurately model the bioremediation process; (4) The discovery that most of the U(VI) contamination at the Rifle site is sediment-associated rather than mobile in the groundwater, as previously considered; (5) The finding that unlike soluble U(VI), sediment-associated U(VI) is not microbially reducible; (6) The demonstration that electrodes may be an effective alternative to acetate as an electron donor to promote microbial U(VI) reduction in the subsurface with the added benefit that electrode-promoted microbial U(VI) reduction offers the possibility of removing the immobilized uranium from the subsurface; and (7) The finding that, after extended acetate inputs, U(VI) continues to be removed from groundwater long after the introduction of acetate into the subsurface is terminated and that this appears to be due to adsorption onto biomass. This potentially will make in situ uranium bioremediation much less expensive than previously envisioned.

  5. Persistent pelvic pain following transvaginal mesh surgery: a cause for mesh removal.

    Science.gov (United States)

    Marcus-Braun, Naama; Bourret, Antoine; von Theobald, Peter

    2012-06-01

    Persistent pelvic pain after vaginal mesh surgery is an uncommon but serious complication that greatly affects women's quality of life. Our aim was to evaluate various procedures for mesh removal performed at a tertiary referral center in cases of persistent pelvic pain, and to evaluate the ensuing complications and outcomes. A retrospective study was conducted at the University Hospital of Caen, France, including all patients treated for removal or section of vaginal mesh due to pelvic pain as a primary cause, between January 2004 and September 2009. Ten patients met the inclusion criteria. Patients were diagnosed between 10 months and 3 years after their primary operation. Eight cases followed suburethral sling procedures and two followed mesh surgery for pelvic organ prolapse. Patients presented with obturator neuralgia (6), pudendal neuralgia (2), dyspareunia (1), and non-specific pain (1). The surgical treatment to release the mesh included: three cases of extra-peritoneal laparoscopy, four cases of complete vaginal mesh removal, one case of partial mesh removal and two cases of section of the suburethral sling. In all patients with obturator neuralgia, symptoms were resolved or improved, whereas in both cases of pudendal neuralgia the symptoms continued. There were no intra-operative complications. Post-operative Retzius hematoma was observed in one patient after laparoscopy. Mesh removal in a tertiary center is a safe procedure, necessary in some cases of persistent pelvic pain. Obturator neuralgia seems to be easier to treat than pudendal neuralgia. Early diagnosis is the key to success in prevention of chronic disease. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Source removal strategy development for manufactured gas plant sites

    International Nuclear Information System (INIS)

    Golchin, J.; Nelson, S.

    1994-01-01

    A source removal action plan was developed by Midwest Gas and the Iowa Department of Natural Resources to address the source coal tar contamination within the underground gas holder basin at former Manufactured Gas Plant (MGP) sites. The procedure utilizes a mixture of coal, contaminated soil and coal rat sludge to provide a material that had suitable material handling characteristics for shipment and burning in high efficiency utility boilers. Screening of the mixture was required to remove oversized debris and ferrous metal. The resulting mixture did not exhibit toxic characteristics when tested under the Toxicity Characteristics Leaching Procedure (TCLP). Test results on the coal tar sludges have indicated that the more pure coal tar materials may fail the TCLP test and be classified as a RCRA hazardous waste. The processing procedure was designed to stabilize the coal tar sludges and render those sludges less hazardous and, as a result, able to pass the TCLP test. This procedure was adopted by the Edison Electric Institute to develop a national guidance document for remediation of MGP sites. The EPA Office of Solid Waste and Emergency Response recommended this strategy to the Regional Waste Management Directors as a practical tool for handling wastes that may exhibit the RCRA characteristics

  7. Pure transvaginal excision of mesh erosion involving the bladder.

    Science.gov (United States)

    Firoozi, Farzeen; Goldman, Howard B

    2013-06-01

    We present a pure transvaginal approach to the removal of eroded mesh involving the bladder secondary to placement of transvaginal mesh for management of pelvic organ prolapse (POP) using a mesh kit. Although technically challenging, we demonstrate the feasibility of a purely transvaginal approach, avoiding a potentially more morbid transabdominal approach. The video presents the surgical technique of pure transvaginal excision of mesh erosion involving the bladder after mesh placement using a prolapse kit was performed. This video shows that purely transvaginal removal of mesh erosion involving the bladder can be done safely and is feasible.

  8. Chest Wall Constriction after the Nuss Procedure Identified from Chest Radiograph and Multislice Computed Tomography Shortly after Removal of the Bar.

    Science.gov (United States)

    Chang, Pei-Yeh; Zeng, Qi; Wong, Kin-Sun; Wang, Chao-Jan; Chang, Chee-Jen

    2016-01-01

    This study radiographically examined the changes in the chest walls of patients with pectus excavatum (PE) after Nuss bar removal, to define the deformation caused by the bar and stabilizer. In the first part of the study, we compared the changes in chest radiographs of patients with PE to a preoperation PE control group. In the second part, we used multislice computed tomography (CT) scans to provide three-dimensional reconstructions with which to evaluate the changes to the thoracic wall. Part 1 From June 2006 to August 2011, 1,125 patients with PE who had posteroanterior chest radiographs taken before undergoing the Nuss procedure at four hospitals were enrolled as a preoperative control group. At the same time, 203 patients who had the bar removed were enrolled as the study group. The maximum dimensions of the outer boundary of the first to ninth rib pairs (R1-R9, rib pair width), chest height, and chest width were measured. Part 2 Thirty-one consecutive patients with PE (20 males and 11 females) who underwent Nuss bar removal were evaluated 7 to 30 days after operation. During this period, a further 34 patients with PE who had undergone CT imaging before bar insertion were evaluated and compared with the postoperative group. Part 1 The width of the lower ribs (R4-R9) after bar removal was significantly less than in the age-matched controls. The ribs adjacent to the bar (R5-R7) showed the greatest restriction. The width of the upper ribs (R1-R3) 2 to 3 years after bar placement did not differ significantly from the controls. Patients who were operated on after 10 years of age had less of a restrictive effect. Three years of bar placement resulted in more restriction than a 2-year period, particularly in patients younger than 10 years old. Part 2: A significant constriction of the chest wall was observed in 13 patients after removal of the Nuss bar. Constriction at ribs 5 to 8 was found to be present adjacent to the site of bar insertion. However

  9. Efficacy of peritoneal dialysis during infusion and drainage procedures.

    Science.gov (United States)

    Baczyski, Daniel; Antosiewicz, Stefan; Waniewski, Jacek; Nowak, Zbigniew; Wakowicz, Zofia

    2010-01-01

    Inadequate dialysis is still a major cause of technique failure in peritoneal dialysis (PD). Mathematical models provide the possibility of direct and precise assessment of peritoneal transport of urea and creatinine throughout the dwell and allow calculation of optimal schedules, dwell times, and predicted adequacy of a prescribed regimen. Kinetic modeling is particularly important for automated PD. If the effectiveness of uremic toxin removal that takes place during infusion and drainage of dialysis fluid is not taken into account, the predicted adequacy of the whole PD session may be underestimated. ♢ To estimate the efficacy of urea and creatinine removal during the dialysis fluid exchange procedure. ♢ 17 patients treated with PD were included in the study. PD effectiveness during dialysate exchange was defined as the quotient k of removed amount of creatinine/BUN during the infusion and drainage of dialysate and during a dwell of the same duration as the dialysate exchange. ♢ The effectiveness of creatinine and urea removal was reduced during the exchange procedure (k(creat) = 0.68 ± 0.43 and k(BUN) = 0.87 ± 0.44) and differed between these 2 solutes (p = 0.0009). The k coefficients for urea and creatinine were well correlated (R(2) = 0.83). ♢ The effectiveness of peritoneal transport of creatinine and BUN during the inflow/outflow phase was relatively high compared to that during the same dwell time (68% and 87% respectively). This real effectiveness of the dialysate exchange procedure should be taken into account in the process of planning automated PD sessions, otherwise the predicted overall efficacy of creatinine and urea removal throughout the session may be underestimated. This underestimation is proportional to the number of dwells per day.

  10. Essure Removal for the Treatment of Device-Attributed Symptoms: An Expanded Case Series and Follow-up Survey.

    Science.gov (United States)

    Clark, Nisse V; Rademaker, Doortje; Mushinski, Avery A; Ajao, Mobolaji O; Cohen, Sarah L; Einarsson, Jon I

    To evaluate perioperative outcomes and symptom resolution in women undergoing removal of the Essure device for device-attributed symptoms. Retrospective case series and follow-up patient survey (Canadian Task Force classification III). Large academic medical center. Fifty-two women who underwent laparoscopic or hysteroscopic Essure removal between 2012 and 2016. Women underwent one of four procedures: laparoscopic hysterectomy (LH) and bilateral salpingectomy (BS), laparoscopic BS and cornuectomy, laparoscopic Essure removal and BS, or hysteroscopic Essure removal and laparoscopic BS. Fifty-two women who underwent Essure removal were asked to complete a survey regarding symptom resolution and quality of life following the procedure. Thirty-two women (61.5%) responded to the survey. Seventy-five percent (24/32) reported almost total or total improvement in quality of life, 56.3% (18/32) for sex life, 53.1% (17/32) for pelvic pain, and 65.6% (21/32) for daily activities. The majority of women reported some degree of improvement in all four domains queried (87.5%, 28/32). When asked about their symptoms in general, 31.3% (10/32) of women reported ongoing or worse symptoms after Essure removal. All procedures took approximately one hour (mean 65 min, SD 33 min), were associated with minimal blood loss (mean 31 mL, SD 17), and had no perioperative complications. Essure removal is a procedure that may be effective for treating most women with symptoms attributed to the device. Patients should be counseled that some symptoms may persist or even worsen following surgery. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.

  11. Indications for surgical removal of the eye in adults: a five-year review

    African Journals Online (AJOL)

    Background: To determine the indications and procedures used for removing the eye in adults in our environment. Method: A retrospective study of destructive ocular surgeries carried out between January 1999 and December 2003. Theatre and case records of adult patients that underwent surgical removal of the eye over ...

  12. Acceptance test procedure, 241-SY-101/241-C-106 shot loading system

    International Nuclear Information System (INIS)

    Ostrom, M.J.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101/241-C-106 Shot Loading System. The procedure will test the components of the Shot Loading System and its capability of adequately loading shot into the annular space of the Container. The loaded shot will provide shielding as required for transporting and storage of a contaminated pump after removal from the tank. This test serves as verification that the SLS is acceptable for use in the pump removal operations for Tanks 241-SY-101, 241-C-106 and 241-AY-102. The pump removal operation for these three tanks will be performed by two different organizations with different equipment, but the Shot Loading System will be compatible between the two operations

  13. Robotic removal of eroded vaginal mesh into the bladder.

    Science.gov (United States)

    Macedo, Francisco Igor B; O'Connor, Jeffrey; Mittal, Vijay K; Hurley, Patrick

    2013-11-01

    Vaginal mesh erosion into the bladder after midurethral sling procedure or cystocele repair is uncommon, with only a few cases having been reported in the literature. The ideal surgical management is still controversial. Current options for removal of eroded mesh include: endoscopic, transvaginal or abdominal (either open or laparoscopic) approaches. We, herein, present the first case of robotic removal of a large eroded vaginal mesh into the bladder and discuss potential benefits and limitations of the technique. © 2013 The Japanese Urological Association.

  14. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  15. Assembly procedure for Shot Loading Platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Shot Loading Platform. The Shot Loading Platform is used by multiple equipment removal projects to load shielding shot in the annular spaces of the equipment storage containers. The platform height is adjustable to accommodate different sizes of storage containers and transport assemblies

  16. A novel stone retrieval basket for more efficient lithotripsy procedures.

    Science.gov (United States)

    Salimi, N; Mahajan, A; Don, J; Schwartz, B

    2009-01-01

    This paper presents the development of an improved stone retrieval device that uses a newly designed cage of Nitinol wires encompassing a mesh basket made of a material that is laser resistant. Current methods to extract large stones involve imaging, using a laser to fragment the stones and then using existing cage-like baskets to trap the fragments individually and extracting them one at a time. These procedures are tedious, and may result in leaving some fragments behind that can reform causing the need for another procedure. The device presented in this paper will have a mesh-like sack which will consist of a laser resistant material of polytetrafluoroethylene (PTFE) enclosed within a newly designed Nitinol cage. Two alternate designs are provided for the cage in this paper. The handle of the device is revised to allow for a 3 Fr (1 mm) opening such that a laser's fiber optic cable can enter the device. Using this device a laser can be used to fragment the stone, and all the fragments are retained in the basket in both the design options. The basket can then be retracted allowing for the retrieval of all the fragments in one shot. The stone retrieval basket presented in this paper will significantly improve the efficiency and effectiveness of lithotripsy procedures for removal of large kidney and biliary tract stones.

  17. Single-piece maintenance procedures for the TITAN reversed-field pinch reactor

    International Nuclear Information System (INIS)

    Grotz, S.P.; Creedon, R.L.; Cooke, P.I.H.; Duggan, W.P.; Krakowski, R.A.; Najmabadi, F.; Wong, C.P.C.

    1987-01-01

    The TITAN reactor is a compact (major radius of 3.9 m and minor plasma radius of 0.6 m), high neutron wall loading (--18MW/m 2 ) fusion energy system based on the reversed-field pinch (RFP) concept. The TITAN-I fusion power core (FPC) is a lithium, self-cooled design with vanadium alloy (V-3Ti-1Si) structural material. The compact design of the TITAN fusion power core (FPC) reduces the system to a few small and relatively low mass components, making toroidal segmentation of the FPC unnecessary. A single-piece maintenance procedure in which the replaceable first wall and blanket is removed as a single unit is, therefore, possible. The TITAN FPC design provides for top access to the reactor with vertical lifts used to remove the components. The number of remote handling procedures is few and the movements are uncomplicated. The annual torus replacement requires that the reusable ohmic-heating coil set and hot-shield assembly be removed and temporarily stored in a hot cell. The used first wall and blanket assembly is drained and disconnected from the coolant supply system, then lifted to a processing room where it is cooled and prepared for Class-C waste burial. The new, pre-tested first wall and blanket assembly is then lowered into position and the removal procedure is reversed to complete the replacement process

  18. Oil adsorbing package, also procedure to remove oil from a water surface

    Energy Technology Data Exchange (ETDEWEB)

    1971-05-01

    A method is given to remove oil from water to prevent water pollution. Use is made of an oil-adsorbing packet having a specific gravity which is lower than the specific gravity of water. The hull is manufactured from any material which is not a water-insoluble nonpolar material. The hull is partly permeable to water and encloses a solid oil-adsorbing compound having a large adsorbing surface. (10 claims)

  19. Laser and intense pulsed light hair removal technologies

    DEFF Research Database (Denmark)

    Haedersdal, M; Beerwerth, F; Nash, J F

    2011-01-01

    Light-based hair removal (LHR) is one of the fastest growing, nonsurgical aesthetic cosmetic procedures in the United States and Europe. A variety of light sources including lasers, e.g. alexandrite laser (755 nm), pulsed diode lasers (800, 810 nm), Nd:YAG laser (1064 nm) and broad-spectrum intense...

  20. 16 CFR 1031.11 - Procedural safeguards.

    Science.gov (United States)

    2010-01-01

    ....11 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION GENERAL COMMISSION PARTICIPATION AND COMMISSION EMPLOYEE INVOLVEMENT IN VOLUNTARY STANDARDS ACTIVITIES Employee Involvement § 1031.11 Procedural... employees may be involved in voluntary standards activities that will further the objectives and programs of...

  1. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  3. Job Satisfaction, Organizational Commitment and Job Involvement: The Mediating Role of Job Involvement.

    Science.gov (United States)

    Ćulibrk, Jelena; Delić, Milan; Mitrović, Slavica; Ćulibrk, Dubravko

    2018-01-01

    We conducted an empirical study aimed at identifying and quantifying the relationship between work characteristics, organizational commitment, job satisfaction, job involvement and organizational policies and procedures in the transition economy of Serbia, South Eastern Europe. The study, which included 566 persons, employed by 8 companies, revealed that existing models of work motivation need to be adapted to fit the empirical data, resulting in a revised research model elaborated in the paper. In the proposed model, job involvement partially mediates the effect of job satisfaction on organizational commitment. Job satisfaction in Serbia is affected by work characteristics but, contrary to many studies conducted in developed economies, organizational policies and procedures do not seem significantly affect employee satisfaction.

  4. Job Satisfaction, Organizational Commitment and Job Involvement: The Mediating Role of Job Involvement

    Science.gov (United States)

    Ćulibrk, Jelena; Delić, Milan; Mitrović, Slavica; Ćulibrk, Dubravko

    2018-01-01

    We conducted an empirical study aimed at identifying and quantifying the relationship between work characteristics, organizational commitment, job satisfaction, job involvement and organizational policies and procedures in the transition economy of Serbia, South Eastern Europe. The study, which included 566 persons, employed by 8 companies, revealed that existing models of work motivation need to be adapted to fit the empirical data, resulting in a revised research model elaborated in the paper. In the proposed model, job involvement partially mediates the effect of job satisfaction on organizational commitment. Job satisfaction in Serbia is affected by work characteristics but, contrary to many studies conducted in developed economies, organizational policies and procedures do not seem significantly affect employee satisfaction. PMID:29503623

  5. Prolapse Recurrence after Transvaginal Mesh Removal.

    Science.gov (United States)

    Rawlings, Tanner; Lavelle, Rebecca S; Coskun, Burhan; Alhalabi, Feras; Zimmern, Philippe E

    2015-11-01

    We determined the rate of pelvic organ prolapse recurrence after transvaginal mesh removal. Following institutional review board approval a longitudinally collected database of women undergoing transvaginal mesh removal for complications after transvaginal mesh placement with at least 1 year minimum followup was queried for pelvic organ prolapse recurrence. Recurrent prolapse was defined as greater than stage 1 on examination or the need for reoperation at the site of transvaginal mesh removal. Outcome measures were based on POP-Q (Pelvic Organ Prolapse Quantification System) at the last visit. Patients were grouped into 3 groups, including group 1--recurrent prolapse in the same compartment as transvaginal mesh removal, 2--persistent prolapse and 3--prolapse in a compartment different than transvaginal mesh removal. Of 73 women 52 met study inclusion criteria from 2007 to 2013, including 73% who presented with multiple indications for transvaginal mesh removal. The mean interval between insertion and removal was 45 months (range 10 to 165). Overall mean followup after transvaginal mesh removal was 30 months (range 12 to 84). In group 1 (recurrent prolapse) the rate was 15% (6 of 40 patients). Four women underwent surgery for recurrent prolapse at a mean 7 of months (range 5 to 10). Two patients elected observation. The rate of persistent prolapse (group 2) was 23% (12 of 52 patients). Three women underwent prolapse reoperation at a mean of 10 months (range 8 to 12). In group 3 (de novo/different compartment prolapse) the rate was 6% (3 of 52 patients). One woman underwent surgical repair at 52 months. At a mean 2.5-year followup 62% of patients (32 of 52) did not have recurrent or persistent prolapse after transvaginal mesh removal and 85% (44 of 52) did not undergo any further procedure for prolapse. Specifically for pelvic organ prolapse in the same compartment as transvaginal mesh removal 12% of patients had recurrence, of whom 8% underwent prolapse repair

  6. Randomized controlled clinical trial of long-term chemo-mechanical caries removal using PapacarieTM gel

    Directory of Open Access Journals (Sweden)

    Lara Jansiski MOTTA

    2014-07-01

    Full Text Available Objectives: Compare the effectiveness of PapacarieTM gel for the chemo-mechanical removal of carious lesions on primary teeth to conventional caries removal with a low-speed bur with regard to execution time, clinical aspects and radiographic findings. Material and Methods: A randomized controlled clinical trial with a split-mouth design was carried out. The sample was composed of 20 children aged four to seven years, in whom 40 deciduous teeth were randomly divided into two groups: chemo-mechanical caries removal with PapacarieTM and removal of carious dentin with a low-speed bur. Each child underwent both procedures and served as his/her own control. Restorations were performed with glass ionomer cement. The time required to perform the procedure was also analyzed. The patients underwent longitudinal clinical and radiographic follow-up of the restorations. Results: No statistically significant difference between groups was found regarding the time required to perform the procedures and the radiographic follow up. Statistically significant differences between groups were found in the clinical evaluation at 6 and 18 months after treatment. Conclusion: PapacarieTM is as effective as the traditional method for the removal of carious dentin on deciduous teeth, but offers the advantages of the preservation of sound dental tissue as well as the avoidance of sharp rotary instruments and local anesthesia.

  7. Critical analysis of dose reduction trends with special reference to procedures involved in fluoroscopy

    International Nuclear Information System (INIS)

    Anderson, K.; Mattsson, O.

    1985-01-01

    Experiences of a half-year's use of dose-checking instrumentation in fluoroscopy are presented. Radiologists under training succeeded in lowering the patient dose surprisingly well - the diagnostic results remaining unchanged or even improving, because of higher image quality as a result of better diaphragming. Other factors involved in fluoroscopy are discussed. Present systems with heavy bulky intensifiers create problems for close patient contact and for the necessary manipulation, patient adjustment and application of compression. The examination will be simplified and facilitated by the use of a flat image system: proper adjustments need fewer fluoroscopic observations, and patient dose as well as examination time can be saved. Flat display principles will take over the function of the present old-fashioned intensifiers and monitors, either as single units or equipped with TV, video or digital processing accessories. A flat image system, the 'PET-scope', was tested and found to be very convenient for fluoroscopic procedures. The physical properties were studied thoroughly - the high intensification particularly gives these systems an advantage in dose reduction. New applications are possible with these light-weight low-dose units. Fluoroscopy represents a field where considerable contributions to the 'Quality Assurance' trend can be obtained. (author)

  8. Removal of a seized fuel channel from the KANUPP reactor

    International Nuclear Information System (INIS)

    Butt, W.M.; Gunn, R.J.

    1995-01-01

    In support of the Safe operation of KANUPP program, AECL was commissioned in early 1992 to assist the Karachi Nuclear Power Plant in the design and supply of equipment and procedures for removal of a seized fuel channel from the KANUPP CANDU reactor. In addition AECL was also asked to supply technical site support to assist the KANUPP station staff during the removal of the G-12 channel. The design of a fuel channel removal system presented an interesting challenge. The fuel channel design was unique to KANUPP with no history of previous channel removal, consequently nearly all tools and equipment had to be specially designed. In addition, the seized end fitting posed a special problem requiring the development several contingency tools and techniques. This paper is an account of the design and development of the removal system and the site experiences during the actual fuel channel removal. After the channel had been removed, it was confirmed that a corrosion seizure between the end fitting sleeve bearings was inhibiting normal channel elongation. (author)

  9. Experience with after-shutdown decay heat removal - BWRs and PWRs

    International Nuclear Information System (INIS)

    Haugh, J.J.; Mollerus, F.J.; Booth, H.R.

    1992-01-01

    Boiling-water reactors (BWRs) and pressurized-water reactors (PWRs) make use of residual heat removal systems (RHRSs) during reactor shutdown. RHRS operational events involving an actual loss or significant degradation of an RHRS during shutdown heat removal are often prompted or aggravated by complex, changing plant conditions and by concurrent maintenance operations. Events involving loss of coolant inventory, loss of decay heat removal capability, or inadvertent pressurization while in cold shutdown have occurred. Because fewer automatic protective fetures are operative during cold shutdowns, both prevention and termination of events depend heavily on operator action. The preservation of RHRS cooling should be an important priority in all shutdown operations, particularly where there is substantial decay heat and a reduced water inventory. 13 refs., 3 figs., 4 tabs

  10. Effects of postmyelographic removal of metrizamide in dogs

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.; Cantwell, H.D.; Cook, J.R. Jr.; DeNicola, D.B.

    1990-01-01

    Using a paired crossover trial, the effects of postmyelographic removal of metrizamide injected via the cerebellomedullary cistern were studied in 16 normal dogs. Each animal received a routine and a withdrawal myelogram. Seizure activity, changes in spinal evoked motor potentials and body temperature were measured following each myelogram. The amount of metrizamide removed was determined by densitometrically analyzing radiographs of cerebrospinal fluid/metrizamide aliquots recovered during the withdrawal procedure. There was a significant decrease in the number of seizures for withdrawal versus nonwithdrawal myelography (p < 0.01). The mean amount of metrizamide withdrawn per dog was 29% of the total injected

  11. Control of the ASTRA decay heat removal system

    International Nuclear Information System (INIS)

    Nedelik, A.

    1982-11-01

    To ensure a minimum of core cooling even under severest accident conditions (loss of reactor pool water) a core spray system for decay heat removal has been installed at the ASTRA-reactor. The automatic and manual control of the system, its power supply and test procedures are shortly described. (Author)

  12. 12 CFR 308.602 - Removal, suspension, or debarment.

    Science.gov (United States)

    2010-01-01

    ... for which the FDIC is the appropriate Federal banking agency if, after service of a notice of... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Removal, suspension, or debarment. 308.602 Section 308.602 Banks and Banking FEDERAL DEPOSIT INSURANCE CORPORATION PROCEDURE AND RULES OF PRACTICE...

  13. Investigations in gallium removal

    Energy Technology Data Exchange (ETDEWEB)

    Philip, C.V.; Pitt, W.W. [Texas A and M Univ., College Station, TX (United States); Beard, C.A. [Amarillo National Resource Center for Plutonium, TX (United States)

    1997-11-01

    Gallium present in weapons plutonium must be removed before it can be used for the production of mixed-oxide (MOX) nuclear reactor fuel. The main goal of the preliminary studies conducted at Texas A and M University was to assist in the development of a thermal process to remove gallium from a gallium oxide/plutonium oxide matrix. This effort is being conducted in close consultation with the Los Alamos National Laboratory (LANL) personnel involved in the development of this process for the US Department of Energy (DOE). Simple experiments were performed on gallium oxide, and cerium-oxide/gallium-oxide mixtures, heated to temperatures ranging from 700--900 C in a reducing environment, and a method for collecting the gallium vapors under these conditions was demonstrated.

  14. Investigations in gallium removal

    International Nuclear Information System (INIS)

    Philip, C.V.; Pitt, W.W.; Beard, C.A.

    1997-11-01

    Gallium present in weapons plutonium must be removed before it can be used for the production of mixed-oxide (MOX) nuclear reactor fuel. The main goal of the preliminary studies conducted at Texas A and M University was to assist in the development of a thermal process to remove gallium from a gallium oxide/plutonium oxide matrix. This effort is being conducted in close consultation with the Los Alamos National Laboratory (LANL) personnel involved in the development of this process for the US Department of Energy (DOE). Simple experiments were performed on gallium oxide, and cerium-oxide/gallium-oxide mixtures, heated to temperatures ranging from 700--900 C in a reducing environment, and a method for collecting the gallium vapors under these conditions was demonstrated

  15. Conceptual design of cesium removal device for ITER NBI maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Shibanuma, Kiyoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Cesium is required in order to generate a stable negative ion of hydrogen in an ion source of the neutral beam injector (NBI), which is one of the plasma-heating devices for International Thermonuclear Experimental Reactor (ITER). After long time operation of the NBI, the cesium deposits to the insulators supporting the electrode. Due to the deterioration of the insulation resistance, the continuous operation of the NBI will be difficult. In addition, the NBI device is activated by neutrons from D-T plasma, so that periodic removal and cleaning of the cesium on the insulators by remove handling is required. A study of the cesium removal scenario and the device is therefore required considering remote handling. In this report, a cesium removal procedure and conceptual design of the cesium removal device using laser ablation technique are studied, and the feasibility of the laser ablation method is shown. (author)

  16. Comparison of clinical outcomes of intraventricular hematoma between neuroendoscopic removal and extraventricular drainage

    International Nuclear Information System (INIS)

    Komatsu, Fuminari; Komatsu, Mika; Wakuta, Naoki; Oshiro, Shinaya; Tsugu, Hitoshi; Iwaasa, Mitsutoshi; Inoue, Tooru

    2010-01-01

    The efficacy of treatment for intraventricular hematoma by neuroendoscopic surgery and extraventricular drainage was compared in 10 patients with intraventricular hematoma and hydrocephalus who underwent neuroendoscopic surgery (endoscopic group), and eight patients with intraventricular hematoma and hydrocephalus treated with extraventricular drainage (EVD group). The outcomes in each group were assessed retrospectively using the Graeb scores on the pre- and postoperative computed tomography (CT), duration of extraventricular drainage, requirement for a shunt operation, and modified Rankin scale score at 12 months. The Graeb scores on the preoperative CT were not significantly different between the two groups, but the duration of catheter placement was significantly shorter (69.3%) in the endoscopic group (2.7 days) than in the EVD group (8.8 days). None of the patients in either group required a shunt procedure for communicating hydrocephalus 12 months after surgery. Neuroendoscopic removal is a safe and effective procedure for intraventricular hematoma. Advantages include rapid removal of hematoma in the ventricular systems and reliable improvement of non-communicating hydrocephalus in the acute phase. The procedure resulted in faster removal of the catheter in the postoperative period and earlier patient ambulation. (author)

  17. Comparison of rigid and flexible endoscopy for removing esophageal foreign bodies in an emergency.

    Science.gov (United States)

    Tseng, Chia-Chen; Hsiao, Tzu-Yu; Hsu, Wei-Chung

    2016-08-01

    Despite the effectiveness of endoscopies in removing ingested foreign bodies (FBs) impacted in the esophagus, the merits and limitations of flexible endoscopy (FE) and rigid endoscopy (RE) remain unclear. Therefore, this study compares the advantages and disadvantages of both endoscopic procedures from a clinical perspective. A retrospective review was made of 273 patients suspected of esophageal FBs in emergency consultations of a tertiary medical referral center from March 2010 to March 2014. All patients received routine physical examinations, otolaryngological examinations, and X-rays of the neck and chest. The door-to-endoscopy time, procedure time, postendoscopic hospital stay, successful removal rates, and complications were analyzed as well. In this study, the most common esophageal FBs were fish and animal bones (76%) in adults and coins (74%) in children. The patients with existing esophageal FBs had significantly more frequent symptoms of dysphagia and signs of linear opacity as detected with lateral neck radiography than those without FB. Additionally, the door-to-endoscopy time, procedure time, and postendoscopic hospital stay was significantly shorter in FE patients than in RE patients. However, both RE and FE patients had high rates of successful FB removal (95%) and low complication rates (2%). Both FE and RE remove esophageal FBs successfully, as evidenced by their high success rates, low complication rates, and high detection rates. Although FE under local anesthesia is a less time-consuming procedure for adults, RE under general anesthesia may be preferable for children and can serve as an alternative to FE. Copyright © 2015. Published by Elsevier B.V.

  18. Evaluation of enamel micro-cracks characteristics after removal of metal brackets in adult patients.

    Science.gov (United States)

    Dumbryte, Irma; Linkeviciene, Laura; Malinauskas, Mangirdas; Linkevicius, Tomas; Peciuliene, Vytaute; Tikuisis, Kristupas

    2013-06-01

    The purpose of this study was to evaluate and compare enamel micro-crack characteristics of adult patients before and after removal of metal brackets. After the examination with scanning electron microscopy (SEM), 45 extracted human teeth were divided into three groups of equal size: group 1, the teeth having enamel micro-cracks, group 2, the teeth without initial enamel micro-cracks, and group 3, control group to study the effect of dehydration on existing micro-cracks or formation of new ones. For all the teeth in groups 1 and 2, the same bonding and debonding procedures of metal brackets were conducted. The length and width of the longest enamel micro-crack were measured for all the teeth before and after removal of metal brackets. The changes in the location of the micro-cracks were also evaluated. In group 3, teeth were subjected to the same analysis but not bonded. The mean overall width of micro-cracks after removal of metal brackets was 3.82 μm greater than before bonding procedure (P cracks in first zone (cervical third) and third zone (occlusal third) after debonding procedure (P enamel micro-cracks were found in 6 of 15 (40 per cent) examined teeth. Greatest changes in the width of enamel micro-cracks after debonding procedure appear in the cervical third of the tooth. On the basis of this result, the dentist must pay extra care and attention to this specific area of enamel during removal of metal brackets in adult patients.

  19. Efficient bounding schemes for the two-center hybrid flow shop scheduling problem with removal times.

    Science.gov (United States)

    Hidri, Lotfi; Gharbi, Anis; Louly, Mohamed Aly

    2014-01-01

    We focus on the two-center hybrid flow shop scheduling problem with identical parallel machines and removal times. The job removal time is the required duration to remove it from a machine after its processing. The objective is to minimize the maximum completion time (makespan). A heuristic and a lower bound are proposed for this NP-Hard problem. These procedures are based on the optimal solution of the parallel machine scheduling problem with release dates and delivery times. The heuristic is composed of two phases. The first one is a constructive phase in which an initial feasible solution is provided, while the second phase is an improvement one. Intensive computational experiments have been conducted to confirm the good performance of the proposed procedures.

  20. Standard Review Plan Update and Development Program. Implementing Procedures Document

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  1. A simple filtration method to remove plankton-associated Vibrio cholerae in raw water supplies in developing countries.

    Science.gov (United States)

    Huq, A; Xu, B; Chowdhury, M A; Islam, M S; Montilla, R; Colwell, R R

    1996-07-01

    Plankton to which cells of Vibrio cholerae O1 and/or O139 were attached was introduced into 0.5% Instant Ocean microcosms maintained at 25 degrees C. The bulk of the plankton and associated particulates was removed with a filter constructed from either nylon net and one of several different types of sari material, the latter being very inexpensive and readily available in villages in Bangladesh, where V. cholerae is endemic. V. cholerae was enumerated before and after filtration to evaluate the efficiency of the filtration procedure. The results obtained indicate that 99% of V. cholerae, i.e., those cells attached to plankton, were removed from the water samples. Epidemic strains of V. cholerae O1 and O139 from various geographical sources, including Bangladesh, Brazil, India, and Mexico, were included in the experiments. Removal of vibrios from water by this simple filtration method was found to yield consistent results with all strains examined in this study. Thus, it is concluded that a simple filtration procedure involving the use of domestic sari material can reduce the number of cholera vibrios attached to plankton in raw water from ponds and rivers commonly used for drinking. Since untreated water from such sources serves as drinking water for millions of people living in developing countries (e.g., Bangladesh), filtration should prove effective at reducing the incidence and severity of outbreaks, especially in places that lack fuel wood for boiling water and/or municipal water treatment plants. The results of this study provide the basis for determining such reductions, which are to be carried out in the near future.

  2. Cloud-based Electronic Test Procedures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Test procedures are at the heart of any experimental process, especially those involving novel and complex hardware. Whether these procedures are for system...

  3. Tattoo removal in the typical adolescent

    Science.gov (United States)

    2011-01-01

    Background Although popular tattoos are often regretted later on for different reasons. Nevertheless, tattoo removal is a complicated and costly procedure seldom providing satisfactory results. The aim of this study was to investigate the awareness of the implications of tattoo removal among a substantial sample of Italian secondary school adolescents. Findings Students were recruited by a stratified convenience sample and surveyed by a self administered questionnaire. Logistic regression analysis was performed, reporting adjusted Odds Ratios (OR), with 95% Confidence Interval (CI). 4,277 pupils returned a usable questionnaire. Piercings were more frequently undertaken than tattoos. Only 40% of the respondents were aware of the issues related to tattoo removal. Males and pupils with younger fathers were less likely to be aware, whereas students satisfied with their physical appearance and those with a positive attitude towards body art were more likely to be aware. Conclusions Male adolescents with younger fathers can be regarded as the ideal target of corporate health education programs driven by school counsellors and primary care physicians. PMID:21693015

  4. Tattoo removal in the typical adolescent

    Directory of Open Access Journals (Sweden)

    Mazzoleni Francesco F

    2011-06-01

    Full Text Available Abstract Background Although popular tattoos are often regretted later on for different reasons. Nevertheless, tattoo removal is a complicated and costly procedure seldom providing satisfactory results. The aim of this study was to investigate the awareness of the implications of tattoo removal among a substantial sample of Italian secondary school adolescents. Findings Students were recruited by a stratified convenience sample and surveyed by a self administered questionnaire. Logistic regression analysis was performed, reporting adjusted Odds Ratios (OR, with 95% Confidence Interval (CI. 4,277 pupils returned a usable questionnaire. Piercings were more frequently undertaken than tattoos. Only 40% of the respondents were aware of the issues related to tattoo removal. Males and pupils with younger fathers were less likely to be aware, whereas students satisfied with their physical appearance and those with a positive attitude towards body art were more likely to be aware. Conclusions Male adolescents with younger fathers can be regarded as the ideal target of corporate health education programs driven by school counsellors and primary care physicians.

  5. Comparison of simple and economical photocatalyst immobilisation procedures

    DEFF Research Database (Denmark)

    Lim, L.L.P.; Lynch, R.J.; In, Su-il

    2009-01-01

    Photocatalysis is extremely useful for the removal of organic contaminants in water. However, the conditions used for preparing and fixing the catalyst to a substrate have a great effect on its performance. The determination of a suitable immobilisation procedure for specific application becomes...

  6. Acceptance test procedure for High Pressure Water Jet System

    International Nuclear Information System (INIS)

    Crystal, J.B.

    1995-01-01

    The overall objective of the acceptance test is to demonstrate a combined system. This includes associated tools and equipment necessary to perform cleaning in the 105 K East Basin (KE) for achieving optimum reduction in the level of contamination/dose rate on canisters prior to removal from the KE Basin and subsequent packaging for disposal. Acceptance tests shall include necessary hardware to achieve acceptance of the cleaning phase of canisters. This acceptance test procedure will define the acceptance testing criteria of the high pressure water jet cleaning fixture. The focus of this procedure will be to provide guidelines and instructions to control, evaluate and document the acceptance testing for cleaning effectiveness and method(s) of removing the contaminated surface layer from the canister presently identified in KE Basin. Additionally, the desired result of the acceptance test will be to deliver to K Basins a thoroughly tested and proven system for underwater decontamination and dose reduction. This report discusses the acceptance test procedure for the High Pressure Water Jet

  7. Removable splint with locking attachments for maxillary distraction osteogenesis with the RED system.

    Science.gov (United States)

    Suzuki, E Y; Suzuki, B

    2007-12-01

    The external traction hooks of the intraoral splint used to control traction forces applied to the maxilla with the rigid external distraction system represent a major barrier to surgical procedures. The purpose of this article is to introduce a removable intraoral splint with locking attachments that can be placed post-surgically immediately before distraction, facilitating surgery and consequently reducing the operative time. Fifteen cleft lip and palate patients underwent maxillary distraction osteogenesis using a rigid external distraction device in combination with the proposed removable splint that was fixed onto the maxillary teeth to provide anchorage. Initial records showed severe maxillary hypoplasia and negative overjet. The removable splint was fabricated using 1.5-mm diameter stainless-steel rigid orthodontic wires soldered to the locking attachments (Y&B Products LP, Chiang Mai, Thailand), making possible its placement post-surgically. Stable splint fixation was achieved prior to the distraction procedure and the desired treatment goals were reached. No complications inserting or removing the splint post-surgically, including pain or discomfort, were observed. The use of the removable splint with locking attachments has proved to be a highly effective fixation approach to manage the severely hypoplastic maxilla, eliminating lip constraints resulting from scarring, and allowing for easier, more deliberate and careful dissection.

  8. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  9. Assessment of the mechanisms involved in the removal of emerging contaminants by microalgae from wastewater: a laboratory scale study

    International Nuclear Information System (INIS)

    Matamoros, Víctor; Uggetti, Enrica; García, Joan; Bayona, Josep M.

    2016-01-01

    Highlights: • The effect of microalage on the removal of emerging contaminants has been evaluated. • Volatilization was relevant for compounds with a moderate Henry’s law constant. • Biodegradation was the main factor for the removal of caffeine and ibuprofen. • Ibuprofen enantioselective biodegradation was observed. • CA-ibuprofen and OH-ibuprofen followed the concentration decline of ibuprofen. - Abstract: Aerated batch reactors (2.5 L) fed either with urban or synthetic wastewater were inoculated with microalgae (dominated by Chlorella sp. and Scenedesmus sp.) to remove caffeine, ibuprofen, galaxolide, tributyl phosphate, 4-octylphenol, tris(2-chloroethyl) phosphate and carbamazepine for 10 incubation days. Non-aerated and darkness reactors were used as controls. Microalgae grew at a rate of 0.25 d −1 with the complete removal of N-NH 4 during the course of the experiment. After 10 incubation days, up to 99% of the microcontaminants with a Henry’s law constant higher than 3 10 −1 Pa m 3 mol −1 (i.e., 4-octylphenol, galaxolide, and tributyl phosphate) were removed by volatilization due to the effect of air stripping. Whereas biodegradation was effective for removing ibuprofen and caffeine, carbamazepine and tris(2-chloroethyl) phosphate behaved as recalcitrant compounds. The use of microalgae was proved to be relevant for increasing the biodegradation removal efficiency of ibuprofen by 40% and reducing the lag phase of caffeine by 3 days. Moreover, the enantioselective biodegradation of S-ibuprofen suggested a biotic prevalent removal process, which was supported by the identification of carboxy-ibuprofen and hydroxy-ibuprofen. The results from microalgae reactors fed with synthetic wastewater showed no clear evidences of microalgae uptake of any of the studied microcontaminants.

  10. Four osteotomy methods with piezosurgery to remove complicated mandibular third molars: a retrospective study.

    Science.gov (United States)

    Ge, Jing; Yang, Chi; Zheng, Jia-Wei; He, Dong-Mei; Zheng, Ling-Yan; Hu, Ying-Kai

    2014-11-01

    Piezosurgery has been used widely in oral and maxillofacial surgery, but there has been no report systematically describing an osteotomy method with piezosurgery for complicated mandibular third molar removal. The aim of this study was to introduce 4 osteotomy methods using piezosurgery and evaluate their effects. A retrospective study was conducted of patients with a complicated impacted mandibular third molar requiring extraction. The predictor variable was the extraction technique. Four osteotomy methods using piezosurgery were tested according to different impaction types: method 1 involved complete bone removal; method 2 involved segmental bone removal; method 3 involved bone removal combined with tooth splitting; and method 4 involved block bone removal. Outcome variables were success rate, operative time, major complications (including nerve injury, mandible fracture, severe hematoma, or severe edema), and serious pyogenic infection. Data were analyzed using descriptive statistics. The study was composed of 55 patients with 74 complicated impacted mandibular third molars. All impacted mandibular third molars were removed successfully. The average surgical time was 15 minutes (range, 8 to 26 minutes). Thirty-eight molars (51.4%) were extracted by method 1, 18 molars (24.3%) by method 2, 12 molars (16.2%) by method 3, and 6 molars (8.1%) by method 4. Two cases (2.7%) developed postoperative infections and recovered within 1 week using drainage and antibiotic administration. The 4 osteotomy methods with piezosurgery provide effective ways of removing complicated impacted mandibular third molars. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Design procedure for sizing a submerged-bed scrubber for airborne particulate removal

    International Nuclear Information System (INIS)

    Ruecker, C.M.; Scott, P.A.

    1987-04-01

    Performance correlations to design and operate the submerged bed scrubber were developed for various applications. Structural design procedure outlined in this report focuses on off-gas scrubbing for HLW vitrification applications; however, the method is appropriate for other applications

  12. Pollutants in drinking water: their sources, harmful effects and removal procedures

    International Nuclear Information System (INIS)

    Qadeer, R.

    2004-01-01

    The underground water resources available for human consumption are being continuously contaminated by the natural sources and anthropogenic activities. The pollutants include toxic microorganism, inorganic and organic chemical and radionuclide etc. this is an acute problem in our country, where free style way of disposal of industrial effluents into the natural water bodies contaminates the surface and ground water. These contaminants make their way into human body through contaminated drinking water, which leads to the malfunctioning of the body organs. Details of some pollutants present in drinking water, their source and harmful effects on human beings are reviewed in this communication. Merits and demerits of methods used to remove the pollutants from drinking water are also discussed. (author)

  13. Internal deposition of radiostrontium and its removal

    International Nuclear Information System (INIS)

    George, G.A.; Mehdi, E.I.; Toma, N.A.

    1979-01-01

    The purpose of the investigation was to study the metabolism of 90 Sr relative to that of calcium and the possible procedures that might enhance its decorporation. One per cent only of an injected dose of the tracer was detected per 100 ml of blood 24 hours after the introduction of this isotope into the rabbit. This dropped to 0.01% 15 days later. Soft tissues contained 10% and 1% of the injected dose one day and 15 days after injection respectively, whereas the bone content reached 23.3% 15 days after tracer injection. In vitro removal experiments showed that a mixture of calcium and calciferol was the most potent agent, causing the removal of 81% of that found in the control animals. In vivo investigations supported the in vitro findings in the use of a calcium-vitamin D mixture, which removed 75% and 45% of the tracer from bones one and four days after isotope injection. These studies also pointed out the importance of time in treatment, and that it could have dramatic effects on the process of removal. The effects of different decorporating agents and their modes of action are also discussed in the paper. (author)

  14. Problems involved in quantitative gamma camera scintigraphy. A. Procedure and definitions

    International Nuclear Information System (INIS)

    Erbsmann, F.

    1976-01-01

    In the procedure used the elementary notions on calibration sources (isotropic point source, parallel-beam point source, tubular line source, parallel-ray line source, sources of finite dimensions, homogeneous phantom) are reviewed, together with the most frequently used definitions, those of the scattering function and of the modulation transfer functions [fr

  15. Investigation on thiosulfate-involved organics and nitrogen removal by a sulfur cycle-based biological wastewater treatment process.

    Science.gov (United States)

    Qian, Jin; Lu, Hui; Cui, Yanxiang; Wei, Li; Liu, Rulong; Chen, Guang-Hao

    2015-02-01

    Thiosulfate, as an intermediate of biological sulfate/sulfite reduction, can significantly improve nitrogen removal potential in a biological sulfur cycle-based process, namely the Sulfate reduction-Autotrophic denitrification-Nitrification Integrated (SANI(®)) process. However, the related thiosulfate bio-activities coupled with organics and nitrogen removal in wastewater treatment lacked detailed examinations and reports. In this study, S2O3(2-) transformation during biological SO4(2-)/SO3(2-) co-reduction coupled with organics removal as well as S2O3(2-) oxidation coupled with chemolithotrophic denitrification were extensively evaluated under different experimental conditions. Thiosulfate is produced from the co-reduction of sulfate and sulfite through biological pathway at an optimum pH of 7.5 for organics removal. And the produced S2O3(2-) may disproportionate to sulfide and sulfate during both biological S2O3(2-) reduction and oxidation most possibly carried out by Desulfovibrio-like species. Dosing the same amount of nitrate, pH was found to be the more direct factor influencing the denitritation activity than free nitrous acid (FNA) and the optimal pH for denitratation (7.0) and denitritation (8.0) activities were different. Spiking organics significantly improved both denitratation and denitritation activities while minimizing sulfide inhibition of NO3(-) reduction during thiosulfate-based denitrification. These findings in this study can improve the understanding of mechanisms of thiosulfate on organics and nitrogen removal in biological sulfur cycle-based wastewater treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. 12 CFR 308.603 - Automatic removal, suspension, and debarment.

    Science.gov (United States)

    2010-01-01

    ... audit services for insured depository institutions for which the FDIC is the appropriate Federal banking... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Automatic removal, suspension, and debarment. 308.603 Section 308.603 Banks and Banking FEDERAL DEPOSIT INSURANCE CORPORATION PROCEDURE AND RULES OF...

  17. Use of Bentonite in residual waters of tanneries for the removal of Cr(III)

    International Nuclear Information System (INIS)

    Echavarria Isaza, Adriana; Moreno Casaf, Monica; Ramirez Ochoa, Claudia; Tamayo Martinez, Claudia; Saldarriaga Molina, Carlos

    1998-01-01

    An efficient procedure is reported for Cr(III) removal from tannery waste waters by means of natural and chemically treated bentonites. The best result was obtained using 20 mL of effluent with 7.5 grams of Bentonite. With this quantity it was removed the total amount of chromium III present in the sample

  18. Acceptance test procedure, 241-SY-101 Flexible Receiver System, Phase III testing

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101 Flexible Receiver System, Phase III Testing. This procedure will test the sealing integrity of the Flexible Receiver System to ensure that release of waste and aerosols will be minimized during the removal of the test mixer pump from tank SY-101

  19. Assessment of the mechanisms involved in the removal of emerging contaminants by microalgae from wastewater: a laboratory scale study

    Energy Technology Data Exchange (ETDEWEB)

    Matamoros, Víctor, E-mail: victor.matamoros@idaea.csic.es [Department of Environmental Chemistry, IDAEA–CSIC, c/Jordi Girona, 18-26, E-08034 Barcelona (Spain); Uggetti, Enrica; García, Joan [GEMMA—Group of Environmental Engineering and Microbiology, Department of Hydraulic, Maritime and Environmental Engineering, Universitat Politècnica de Catalunya BarcelonaTech, c/Jordi Girona, 1-3, Building D1, E-08034 Barcelona (Spain); Bayona, Josep M. [Department of Environmental Chemistry, IDAEA–CSIC, c/Jordi Girona, 18-26, E-08034 Barcelona (Spain)

    2016-01-15

    Highlights: • The effect of microalage on the removal of emerging contaminants has been evaluated. • Volatilization was relevant for compounds with a moderate Henry’s law constant. • Biodegradation was the main factor for the removal of caffeine and ibuprofen. • Ibuprofen enantioselective biodegradation was observed. • CA-ibuprofen and OH-ibuprofen followed the concentration decline of ibuprofen. - Abstract: Aerated batch reactors (2.5 L) fed either with urban or synthetic wastewater were inoculated with microalgae (dominated by Chlorella sp. and Scenedesmus sp.) to remove caffeine, ibuprofen, galaxolide, tributyl phosphate, 4-octylphenol, tris(2-chloroethyl) phosphate and carbamazepine for 10 incubation days. Non-aerated and darkness reactors were used as controls. Microalgae grew at a rate of 0.25 d{sup −1} with the complete removal of N-NH{sub 4} during the course of the experiment. After 10 incubation days, up to 99% of the microcontaminants with a Henry’s law constant higher than 3 10{sup −1} Pa m{sup 3} mol{sup −1} (i.e., 4-octylphenol, galaxolide, and tributyl phosphate) were removed by volatilization due to the effect of air stripping. Whereas biodegradation was effective for removing ibuprofen and caffeine, carbamazepine and tris(2-chloroethyl) phosphate behaved as recalcitrant compounds. The use of microalgae was proved to be relevant for increasing the biodegradation removal efficiency of ibuprofen by 40% and reducing the lag phase of caffeine by 3 days. Moreover, the enantioselective biodegradation of S-ibuprofen suggested a biotic prevalent removal process, which was supported by the identification of carboxy-ibuprofen and hydroxy-ibuprofen. The results from microalgae reactors fed with synthetic wastewater showed no clear evidences of microalgae uptake of any of the studied microcontaminants.

  20. Methods for removal of resin remaining after debonding of orthodontic brackets: A literature review

    Directory of Open Access Journals (Sweden)

    Mateus Rodrigues Tonetto

    2014-01-01

    Full Text Available The removal of resin debris and/or resin cement from the enamel surface without causing iatrogenic is the main objective when removing the orthodontic brackets. Some factors such as the time required for removal, damage to the tooth structure, are essential factors for the clinician at the time of removal. Various techniques are used for the removal of orthodontic brackets after the treatment; it is known that the use of clinical procedures such as the use of diamond burs and some pliers removers can damage the structure of the enamel, often depending on the bond strength that should be taken into consideration at the time of removal. This literature review aims to gather the most relevant studies that can clarify the clinical technique, which may be more suitable for removal of the brackets.

  1. Noninvasive control of dental calculus removal: qualification of two fluorescence methods

    Science.gov (United States)

    Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Biryukova, T.

    2013-02-01

    The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise noninvasive detection of calculus-tooth interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing.

  2. Noninvasive control of dental calculus removal: qualification of two fluorescence methods

    International Nuclear Information System (INIS)

    Gonchukov, S; Sukhinina, A; Bakhmutov, D; Biryukova, T

    2013-01-01

    The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise noninvasive detection of calculus-tooth interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing.

  3. Robotic vascular resections during Whipple procedure

    OpenAIRE

    Allan, Bassan J.; Novak, Stephanie M.; Hogg, Melissa E.; Zeh, Herbert J.

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vas...

  4. Taurolidine as an effective and biocompatible additive for plaque-removing techniques on implant surfaces.

    Science.gov (United States)

    John, Gordon; Schwarz, Frank; Becker, Jürgen

    2015-06-01

    The aim of the present study was the evaluation of the effectiveness and efficiency of two plaque-removing techniques, plastic curettes (PC) and glycine powder airflow (GLY) in combination with taurolidine (T), chlorhexidine (CHX), or pure water (PW) as additives and compared to groups without previous treatment (NT). Plaque was collected on titanium samples for 48 h in six subjects. Specimens were worn in a special splint in the upper jaw and randomly assigned to test and control groups. After biofilm removal procedures, clean implant surface (CIS) on the samples and treatment time were taken as parameters. Mean CIS was determined in the following descending order: T-GLY > CHX-GLY > NT-GLY > T-PC > PW-GLY > PW-PC > CHX-PC > NT-PC. Mean treatment time was determined in the following ascending order: T-GLY treatment times of the T groups were significantly lower than their corresponding PC or GLY groups. The results of the current study indicate that taurolidine seems to enhance effectiveness of plaque-removing procedures with plastic curettes and glycine powder airflow. Also, the efficiency of both treatment procedures seems to be increased.

  5. Sodium removal and requalification of secondary loop cold trap

    International Nuclear Information System (INIS)

    Rajan, M.; Veerasamy, R.; Gurumoorthy, K.; Rajan, K.K.; Kale, R.D.

    1997-01-01

    The secondary loop cold trap of the Fast Breeder Test Reactor got plugged prematurely and was not removing impurities from the sodium. This cold trap was taken up for cleaning and modification of the internals. The cleaning operation was carried out successfully by hydride decomposition and vacuum distillation followed by steam cleaning method. Without dismantling, the cold trap internals were washed by circulating water. Subsequently the wire mesh was removed, examined and replaced, the internal modifications were carried (nit and the cold trap way qualified for reuse. The procedures followed and the experience gained are discussed. (author)

  6. Biological removal of phenol from wastewaters: a mini review

    Science.gov (United States)

    Pradeep, N. V.; Anupama, S.; Navya, K.; Shalini, H. N.; Idris, M.; Hampannavar, U. S.

    2015-06-01

    Phenol and its derivatives are common water pollutants and include wide variety of organic chemicals. Phenol poisoning can occur by skin absorption, inhalation, ingestion and various other methods which can result in health effects. High exposures to phenol may be fatal to human beings. Accumulation of phenol creates toxicity both for flora and fauna. Therefore, removal of phenol is crucial to perpetuate the environment and individual. Among various treatment methods available for removal of phenols, biodegradation is environmental friendly. Biological methods are gaining importance as they convert the wastes into harmless end products. The present work focuses on assessment of biological removal (biodegradation) of phenol. Various factors influence the efficiency of biodegradation of phenol such as ability of the microorganism, enzymes involved, the mechanism of degradation and influencing factors. This study describes about the sources of phenol, adverse effects on the environment, microorganisms involved in the biodegradation (aerobic and anaerobic) and enzymes that polymerize phenol.

  7. Design and optimisation of purification procedure for biodiesel washing

    Directory of Open Access Journals (Sweden)

    S.B. Glišić

    2009-09-01

    Full Text Available Almost complete methanolysis of triglycerides is usually not enough to fulfil the strict standards of biodiesel quality. A key step in this process is neutralization of alkali (catalyst followed by the washing procedure necessary for removing different impurities such as traces of catalyst and methanol and removal of soaps and glycerol from esters phase. The washing with hot water is still widely used in many industrial units for the biodiesel production. In this study, different procedures of biodiesel washing using hot water were investigated. The orto-phosphoric acid was suggested as the best compound for alkali catalyst (sodium hydroxide neutralization. The main goal of the performed analysis was to minimize the water usage in the washing-neutralization step during the biodiesel production. Such solution would make the process of biodiesel synthesis more economical taking into account the decrease of energy consumed for evaporation of water during the final product purification, as well as more acceptable procedure related to the impact on environment (minimal waste water release. Results of the performed simulation of the washing process supported by original experimental data suggested that neutralization after the optimized washing process of the methyl ester layer could be the best solution. The proposed washing procedure significantly decreases the amount of waste water giving at the same time the desired purity of final products (biodiesel and glycerol. The simulation of the process was performed using ASPEN plus software supported by ELCANTREL and UNIQUAC procedure of required properties calculation

  8. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  9. Effectiveness of rotatory and reciprocating movements in root canal filling material removal

    Directory of Open Access Journals (Sweden)

    Emmanuel João Nogueira Leal SILVA

    2015-01-01

    Full Text Available The purpose of this study was to compare the efficacy of reciprocating and rotary techniques for removing gutta-percha and sealer from root canals. Forty straight and oval single-rooted premolars were prepared up to size 30, filled with gutta-percha and sealer, and then randomly allocated to two experimental retreatment groups: ProTaper Retreatment System (PTRS and WaveOne System (WS. Procedural errors, time of retreatment and apically extruded material were recorded for all the roots. The roots were radiographed after retreatment. The percentage of residual material was calculated using image analysis software. The data were analyzed by Kolmogorov-Smirnov and t tests, with a significance level set at 5%. No system completely removed the root filling material from the root canal. No significant differences were observed between the systems, in terms of residual filling material in any tested third (p > 0.05. WS was faster in removing filling material than PTRS (p< 0.05. Extrusion was observed in 4 cases in PTRS and in 5 cases in WS. No procedural errors were observed in either group. It can be concluded that although no differences were observed in the efficacy of PTRS and WS for removing root filling material, WS was faster than PTRS.

  10. A Survey Comparing Delegation of Cosmetic Procedures Between Dermatologists and Nondermatologists.

    Science.gov (United States)

    Austin, Molly B; Srivastava, Divya; Bernstein, Ira H; Dover, Jeffrey S

    2015-07-01

    How delegation of procedures varies among cosmetic specialties in the United States is not well described. To better describe current practices in delegation of procedures to nonphysicians among physicians of different cosmetic specialties in the United States. An Internet-based survey was administered to physician members of the American Society for Dermatologic Surgery (ASDS), the American Society for Aesthetic Plastic Surgery (ASAPS), and the American Society for Laser Medicine and Surgery (ASLMS). A total of 823 responses were collected. Two hundred ninety-one of the 521 dermatologists (55.9%) reported delegating cosmetic procedures compared with 223 of the 302 nondermatologists (73.8%) (p delegation occurred, dermatologists were more likely than nondermatologists to delegate the following procedures to higher level non-physician providers (NPP): chemical peels, neuromodulator and filler injections, laser hair removal, pulsed dye laser, tattoo removal, intense pulsed light, nonablative fractional laser, and sclerotherapy. No difference in delegation rate was noted between dermatologists and non-dermatologist physicians with respect to microdermabrasion, ablative fractional laser, cryolipolysis, radiofrequency skin tightening, focused ultrasound skin tightening, and focused ultrasound fat reduction. Dermatologists delegate procedures to NPP less frequently than non-dermatologist physicians, and when they do, it is typically to higher level NPP.

  11. Iron coated pottery granules for arsenic removal from drinking water.

    Science.gov (United States)

    Dong, Liangjie; Zinin, Pavel V; Cowen, James P; Ming, Li Chung

    2009-09-15

    A new media, iron coated pottery granules (ICPG) has been developed for As removal from drinking water. ICPG is a solid phase media that produces a stable Fe-Si surface complex for arsenic adsorption. Scanning electron microscopy (SEM) was used to document the physical attributes (grain size, pore size and distribution, surface roughness) of the ICPG media. Several advantages of the ICPG media such as (a) its granular structure, (b) its ability to absorb As via the F(0) coating on the granules' surface; (c) the inexpensive preparation process for the media from clay material make ICPG media a highly effective media for removing arsenic at normal pH. A column filtration test demonstrated that within the stability region (flow rate lower than 15L/h, EBCT >3 min), the concentration of As in the influent was always lower than 50 microg/L. The 2-week system ability test showed that the media consistently removed arsenic from test water to below the 5 microg/L level. The average removal efficiencies for total arsenic, As(III), and As(V) for a 2-week test period were 98%, 97%, and 99%, respectively, at an average flow rate of 4.1L/h and normal pH. Measurements of the Freundlich and Langmuir isotherms at normal pH show that the Freundlich constants of the ICPG are very close to those of ferric hydroxide, nanoscale zero-valent iron and much higher than those of nanocrystalline titanium dioxide. The parameter 1/n is smaller than 0.55 indicating a favorable adsorption process [K. Hristovski, A. Baumgardner, P. Westerhoff, Selecting metal oxide nanomaterials for arsenic removal in fixed bed columns: from nanopowders to aggregated nanoparticle media, J. Hazard. Mater. 147 (2007) 265-274]. The maximum adsorption capacity (q(e)) of the ICPG from the Langmuir isotherm is very close to that of nanoscale zero-valent indicating that zero-valent iron is involved in the process of the As removal from the water. The results of the toxicity characteristic leaching procedure (TCLP

  12. Iron coated pottery granules for arsenic removal from drinking water

    International Nuclear Information System (INIS)

    Dong Liangjie; Zinin, Pavel V.; Cowen, James P.; Ming, Li Chung

    2009-01-01

    A new media, iron coated pottery granules (ICPG) has been developed for As removal from drinking water. ICPG is a solid phase media that produces a stable Fe-Si surface complex for arsenic adsorption. Scanning electron microscopy (SEM) was used to document the physical attributes (grain size, pore size and distribution, surface roughness) of the ICPG media. Several advantages of the ICPG media such as (a) its granular structure, (b) its ability to absorb As via the F(0) coating on the granules' surface; (c) the inexpensive preparation process for the media from clay material make ICPG media a highly effective media for removing arsenic at normal pH. A column filtration test demonstrated that within the stability region (flow rate lower than 15 L/h, EBCT >3 min), the concentration of As in the influent was always lower than 50 μg/L. The 2-week system ability test showed that the media consistently removed arsenic from test water to below the 5 μg/L level. The average removal efficiencies for total arsenic, As(III), and As(V) for a 2-week test period were 98%, 97%, and 99%, respectively, at an average flow rate of 4.1 L/h and normal pH. Measurements of the Freundlich and Langmuir isotherms at normal pH show that the Freundlich constants of the ICPG are very close to those of ferric hydroxide, nanoscale zero-valent iron and much higher than those of nanocrystalline titanium dioxide. The parameter 1/n is smaller than 0.55 indicating a favorable adsorption process [K. Hristovski, A. Baumgardner, P. Westerhoff, Selecting metal oxide nanomaterials for arsenic removal in fixed bed columns: from nanopowders to aggregated nanoparticle media, J. Hazard. Mater. 147 (2007) 265-274]. The maximum adsorption capacity (q e ) of the ICPG from the Langmuir isotherm is very close to that of nanoscale zero-valent indicating that zero-valent iron is involved in the process of the As removal from the water. The results of the toxicity characteristic leaching procedure (TCLP) analysis

  13. Analysis of microplastics and their removal from water

    OpenAIRE

    Oladejo, Abiola

    2017-01-01

    Removal of microplastics from water was studied using extraction with oil. The aim of the thesis was to remove microplastics from water using an organic medium, and to analyse the amount of microplastics in the media involved. The separation of different microplastic types was done by conducting experiments in the laboratory. The microplastics were made by grinding and sieving plastics with a grinding machine before adding them to water and oil, which serves as the organic medium. Tw...

  14. Robotic vascular resections during Whipple procedure.

    Science.gov (United States)

    Allan, Bassan J; Novak, Stephanie M; Hogg, Melissa E; Zeh, Herbert J

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vascular resections. This report outlines our technique.

  15. Assessment of the mechanisms involved in the removal of emerging contaminants by microalgae from wastewater: a laboratory scale study.

    Science.gov (United States)

    Matamoros, Víctor; Uggetti, Enrica; García, Joan; Bayona, Josep M

    2016-01-15

    Aerated batch reactors (2.5L) fed either with urban or synthetic wastewater were inoculated with microalgae (dominated by Chlorella sp. and Scenedesmus sp.) to remove caffeine, ibuprofen, galaxolide, tributyl phosphate, 4-octylphenol, tris(2-chloroethyl) phosphate and carbamazepine for 10 incubation days. Non-aerated and darkness reactors were used as controls. Microalgae grew at a rate of 0.25 d(-1) with the complete removal of N-NH4 during the course of the experiment. After 10 incubation days, up to 99% of the microcontaminants with a Henry's law constant higher than 3 10(-1) Pa m(3) mol(-1) (i.e., 4-octylphenol, galaxolide, and tributyl phosphate) were removed by volatilization due to the effect of air stripping. Whereas biodegradation was effective for removing ibuprofen and caffeine, carbamazepine and tris(2-chloroethyl) phosphate behaved as recalcitrant compounds. The use of microalgae was proved to be relevant for increasing the biodegradation removal efficiency of ibuprofen by 40% and reducing the lag phase of caffeine by 3 days. Moreover, the enantioselective biodegradation of S-ibuprofen suggested a biotic prevalent removal process, which was supported by the identification of carboxy-ibuprofen and hydroxy-ibuprofen. The results from microalgae reactors fed with synthetic wastewater showed no clear evidences of microalgae uptake of any of the studied microcontaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Consumer involvement in the health technology assessment program.

    Science.gov (United States)

    Royle, Jane; Oliver, Sandy

    2004-01-01

    This study aims to describe a cycle of development leading to sustainable methods for involving consumers in the management of a program commissioning health technology assessment. Staff time was dedicated to developing procedures for recruiting and briefing consumers to participate in prioritizing, commissioning, and reporting research. Resources and support were developed in light of early feedback from consumers and those working with them. These were piloted and amended before being used routinely. Over 4 years, procedures and resources have been developed to support six consumers attending seven to eight prioritization meetings a year; thirty to forty-five consumers each year commenting on research need for particular topics; thirty consumers a year commenting on research proposals, and twenty a year commenting on research reports. The procedures include clear job descriptions, induction and development days, clear briefing materials, payment for substantial tasks, and regularly seeking feedback to improve procedures. Explicit, inclusive, and reproducible methods for supporting consumer involvement that satisfy National Health Service policy recommendations for involving consumers in research require dedicated staff time to support a cycle of organizational development.

  17. Which trees should be removed in thinning?

    Directory of Open Access Journals (Sweden)

    Timo Pukkala

    2015-12-01

    Full Text Available Background: In economically optimal management, trees that are removed in a thinning treatment should be selected on the basis of their value, relative value increment and the effect of removal on the growth of remaining trees. Large valuable trees with decreased value increment should be removed, especially when they overtop smaller trees. Methods: This study optimized the tree selection rule in the thinning treatments of continuous cover management when the aim is to maximize the profitability of forest management. The weights of three criteria (stem value, relative value increment and effect of removal on the competition of remaining trees were optimized together with thinning intervals. Results and conclusions: The results confirmed the hypothesis that optimal thinning involves removing predominantly large trees. Increasing stumpage value, decreasing relative value increment, and increasing competitive influence increased the likelihood that removal is optimal decision. However, if the spatial distribution of trees is irregular, it is optimal to leave large trees in sparse places and remove somewhat smaller trees from dense places. However, the benefit of optimal thinning, as compared to diameter limit cutting is not usually large in pure one-species stands. On the contrary, removing the smallest trees from the stand may lead to significant (30–40 % reductions in the net present value of harvest incomes. Keywords: Continuous cover forestry, Tree selection, High thinning, Optimal management, Spatial distribution, Spatial growth model

  18. Indications and Complications Associated with the Removal of 506 Pieces of Vaginal Mesh Used in Pelvic Floor Reconstruction: A Multicenter Study.

    Science.gov (United States)

    Miklos, John R; Chinthakanan, Orawee; Moore, Robert D; Karp, Deborah R; Nogueiras, Gladys M; Davila, G Willy

    2016-10-26

    Synthetic mesh utilized to treat stress urinary incontinence (SUI) and pelvic organ prolapse (POP) can often result in postoperative complications. The objectives of this study were to determine: 1) the most common indications for mesh removal; 2) the incidences of the removal of specific mesh procedures (such as suburethral sling [SUS], transvaginal mesh [TVM], or sacrocolpopexy); and 3) the idences and types of surgical complications associated with mesh removal. This was a retrospective study. Design Classification: Canadian Task Force II-3. Three tertiary referral centers in the United States. We examined data from all patients at the three centers who underwent surgical removal of synthetic materials from previous SUS, TVM, and sacrocolpopexy procedures for mesh-related complications from 2011 to 2013. Patients underwent vaginal, intra-abdominal, and inguinal mesh revisions by cutting, partial removal, or total removal of the mesh for mesh-related complications. Overall, 445 patients with complications underwent mesh removal laparoscopically, via groin dissection and/or transvaginally. There were a total of 506 mesh products removed. Of these, 56.5% were slings and 43.5% were for pelvic organ prolapse (POP). Synthetic mesh removed from patients included: transvaginal mesh (TVM) anterior for anterior vaginal prolapse, TVM posterior for posterior vaginal prolapse, sacrocolpopexy mesh, and suburethral slings (SUS) for stress urinary incontinence. Synthetic SUS removed included: retropubic (RPS), transobturator (TOT), and single-incision slings (SIS). TOT was the most common type of sling removed. Patients with a sling who only complained of vaginal pain with or without intercourse underwent a vaginal approach for surgical revision/removal of the sling (86.6%). Patients with an RPS with lower abdominal/suprapubic pain and vaginal pain underwent a vaginal and laparoscopic approach for sling removal (18.4%). Patients with a TOT sling who complained of vaginal and

  19. Porcine Circovirus (PCV) Removal by Q Sepharose Fast Flow Chromatography

    Science.gov (United States)

    Yang, Bin; Wang, Hua; Ho, Cintia; Lester, Philip; Chen, Qi; Neske, Florian; Baylis, Sally A; Blümel, Johannes

    2013-01-01

    The recently discovered contamination of oral rotavirus vaccines led to exposure of millions of infants to porcine circovirus (PCV). PCV was not detected by conventional virus screening tests. Regulatory agencies expect exclusion of adventitious viruses from biological products. Therefore, methods for inactivation/removal of viruses have to be implemented as an additional safety barrier whenever feasible. However, inactivation or removal of PCV is difficult. PCV is highly resistant to widely used physicochemical inactivation procedures. Circoviruses such as PCV are the smallest viruses known and are not expected to be effectively removed by currently-used virus filters due to the small size of the circovirus particles. Anion exchange chromatography such as Q Sepharose® Fast Flow (QSFF) has been shown to effectively remove a range of viruses including parvoviruses. In this study, we investigated PCV1 removal by virus filtration and by QSFF chromatography. As expected, PCV1 could not be effectively removed by virus filtration. However, PCV1 could be effectively removed by QSFF as used during the purification of monoclonal antibodies (mAbs) and a log10 reduction value (LRV) of 4.12 was obtained. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:1464–1471, 2013 PMID:24039195

  20. Application of a Compact High-Definition Exoscope for Illumination and Magnification in High-Precision Surgical Procedures.

    Science.gov (United States)

    Krishnan, Kartik G; Schöller, Karsten; Uhl, Eberhard

    2017-01-01

    The basic necessities for surgical procedures are illumination, exposure, and magnification. These have undergone transformation in par with technology. One of the recent developments is the compact magnifying exoscope system. In this report, we describe the application of this system for surgical operations and discuss its advantages and pitfalls. We used the ViTOM exoscope mounted on the mechanical holding arm. The following surgical procedures were conducted: lumbar and cervical spinal canal decompression (n = 5); laminotomy and removal of lumbar migrated disk herniations (n = 4); anterior cervical diskectomy and fusion (n = 1); removal of intraneural schwannomas (n = 2); removal of an acute cerebellar hemorrhage (n = 1); removal of a parafalcine atypical cerebral hematoma caused by a dural arteriovenous fistula (n = 1); and microsutures and anastomoses of a nerve (n = 1), an artery (n = 1), and veins (n = 2). The exoscope offered excellent, magnified, and brilliantly illuminated high-definition images of the surgical field. All surgical operations were successfully completed. The main disadvantage was the adjustment and refocusing using the mechanical holding arm. The time required for the surgical operation under the exoscope was slightly longer than the times required for a similar procedure performed using an operating microscope. The magnifying exoscope is an effective and nonbulky tool for surgical procedures. In visualization around the corners, the exoscope has better potential than a microscope. With technical and technologic modifications, the exoscope might become the next generation in illumination, visualization, exposure, and magnification for high-precision surgical procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A novel removable shield attached to C-arm units against scattered X-rays from a patient's side

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Hiroshige [Hokkaido Social Insurance Hospital, Department of Radiology, Sapporo, Hokkaido (Japan); Kanazawa University, Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Science, Kanazawa, Ishikawa (Japan); Koshida, Kichiro; Matsubara, Kosuke [Kanazawa University, School of Health Sciences, College of Medical, Pharmaceutical and Health Sciences, Kanazawa, Ishikawa (Japan); Ishigamori, Osamu [Hokkaido Social Insurance Hospital, Department of Radiology, Sapporo, Hokkaido (Japan)

    2014-08-15

    We invented a drape-like shield against scattered X-rays that can safely come into contact with medical equipment or people during fluoroscopically guided procedures. The shield can be easily removed from a C-arm unit using one hand. We evaluated the use of the novel removable shield during the endoscopic retrograde cholangiopancreatography (ERCP) procedure. We measured the dose rate of scattered X-rays around endoscopists with and without this removable shield and surveyed the occupational doses to the ERCP staff. We also examined the endurance of the shield. The removable shield reduced the dose rate of scattered X-rays to one-tenth and reduced the monthly dose to an endoscopist by at least two-fifths. For 2.5 years, there was no damage to the shield and no loosening of the seam. The bonding of the hook-and-loop fasteners did not weaken, although the powerful double-sided tapes made especially for plastic did. The removable shield can reduce radiation exposure to the ERCP staff and may contribute to reducing the exposure to the eye lenses of operators. It would also be possible to expand its use to other fluoroscopically guided procedures besides ERCP because it is a light, simple, and useful device. (orig.)

  2. Removal of radioactivity and mineral values from uranium mill tailings

    International Nuclear Information System (INIS)

    Williams, J.M.; Cokal, E.J.; Dreesen, D.R.

    1981-01-01

    One possible approach to remedial action on uranium mill tailings involves the removal of the components that are responsible for the environmental concern (notably radon releases) posed by these materials. Removing mineral values at the same time can defray much of the cost. This paper presents laboratory results on sulfuric acid leachings and their effectiveness in accomplishing these aims. 9 figures, 4 tables

  3. Muscle relaxation for individuals having tattoos removed through laser treatment: possible effects regarding anxiety and pain.

    Science.gov (United States)

    Huang, Faye; Chou, Wen-Jiun; Chen, Tien-Hsing; Chen, Ching; Hsieh, Yu-Lian; Chong, Mian-Yoon; Hung, Chi-Fa; Lin, Shu-Ching; Tsai, Hsiu-Huang; Wang, Liang-Jen

    2016-08-01

    Effectively managing pain is vital for the well-being and satisfaction of patients undergoing dermatologic treatments involving lasers. This study investigates the potential outcome of using muscle relaxation techniques to reduce pain among people having their tattoos removed with laser treatment. This study consists of 56 participants (mean age 18.1 ± 2.1 years) that had tattoos removed using the principle of selective photothermolysis. These participants underwent muscle relaxation before receiving the laser treatment. Their peripheral skin temperatures (PST) were measured both at the beginning and the end of the muscle relaxation period. Then, the Beck Anxiety Inventory was applied to evaluate anxiety levels. Once the laser treatment was completed, pain levels were measured using a visual analogue scale. A total of 125 person-sessions of laser treatment and psychometric assessments were performed in this study. The muscle relaxation method significantly increased the PST of the participants while reducing the levels of anxiety and pain throughout the course of the laser treatment procedure. The PST, anxiety scores, and pain scores all showed significant correlations with one another. According to the results obtained, this study proposes that muscle relaxation techniques be considered possibly auxiliary treatment options for individuals having tattoos removed through laser treatment. Additional studies with a comparison group and a larger sample size are required in the future to confirm the effectiveness of such intervention.

  4. Use of aesthetic rhinoplasty procedures in reconstructive nasal surgery.

    Science.gov (United States)

    Ghassemi, Alireza; Rübben, Albert; Bohluli, Behnam; Hölzle, Frank; Ghassemi, Mehrangiz

    2015-01-01

    Resection of cancer often involves the excision of underlying hard tissue, and some procedures in aesthetic rhinoplasty can be used in reconstructive nasal surgery to increase the margin of safety while still achieving an acceptable aesthetic and functional outcome. We have used techniques from aesthetic rhinoplasty to shape the nasal framework. Osteotomy and formation of the tip were used in 17 patients with defects (ranging from 1 to 3.5 cm in size) from the nasal root to the tip of the nose. After the underlying bony or cartilaginous framework, or both, had been removed, the resulting open roof deformity had to be corrected by osteotomy of the bony nasal wall and the tip shaped by excision and suturing, including insertion of the tip graft and columellar strut graft. After this, and narrowing of the nose, the defect was smaller and could be closed with local tissue without tension. There were no deformities in the contour, and patency of the airway was maintained. Patients were satisfied with both the aesthetic and functional results. Although the margin of safety was increased, shaping the nasal framework reduced the size of the defect, which allowed tension-free closure with a local flap. The operation requires a thorough knowledge of procedures used in aesthetic rhinoplasty. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Environmental procedures

    International Nuclear Information System (INIS)

    1992-01-01

    The European Bank has pledged in its Agreement to place environmental management at the forefront of its operations to promote sustainable economic development in central and eastern Europe. The Bank's environmental policy is set out in the document titled, Environmental Management: The Bank's Policy Approach. This document, Environmental Procedures, presents the procedures which the European Bank has adopted to implement this policy approach with respect to its operations. The environmental procedures aim to: ensure that throughout the project approval process, those in positions of responsibility for approving projects are aware of the environmental implications of the project, and can take these into account when making decisions; avoid potential liabilities that could undermine the success of a project for its sponsors and the Bank; ensure that environmental costs are estimated along with other costs and liabilities; and identify opportunities for environmental enhancement associated with projects. The review of environmental aspects of projects is conducted by many Bank staff members throughout the project's life. This document defines the responsibilities of the people and groups involved in implementing the environmental procedures. Annexes contain Environmental Management: The Bank's Policy Approach, examples of environmental documentation for the project file and other ancillary information

  6. Power-line Interference Removal from ECG in Case of Power-line Frequency Variations

    Directory of Open Access Journals (Sweden)

    Todor Stoyanov

    2008-10-01

    Full Text Available The original version of the most successful approach for power-line (PL interference removal from ECG, called subtraction procedure, is based on linear segment detection in the signal and hardware synchronised analogue-to-digital conversion to cope with the PL frequency variations. However, this is not feasible for battery supplied devices and some computer-aided ECG systems. Recent improvements of the procedure apply software measurement of the frequency variations that allow a re-sampling of the contaminated signal with the rated PL frequency followed by interference removal and back re-sampling for restoration of the original time intervals. This study deals with a more accurate software frequency measurement and introduces a notch filtration as alternative to the procedure when no linear segments are encountered for long time, e.g. in cases of ventricular fibrillation or tachycardia. The result obtained with large PL frequency variations demonstrate very small errors, usually in the range of ± 20 μV for the subtraction procedure and ± 60 μV for the notch filtration, the last values strongly depending on the frequency contents of the QRS complexes.

  7. Clinical evaluation of Carisolv in the chemico-mechanical removal of carious dentin.

    Science.gov (United States)

    Munshi, A K; Hegde, A M; Shetty, P K

    2001-01-01

    The Chemo-mechanical caries removal technique involves the application of chemical agents, to cause a selective softening of the carious dentine and facilitate removal by gentle excavation. Carisolv is one such new chemical agent used in this minimal invasive technique of carious dentine removal. The present study was, therefore, undertaken to evaluate the efficacy of Carisolv in the chemo-mechanical removal of carious dentine, the time taken for caries removal, the perception of the treatment by the patient, and to evaluate the restorations, radiographically. Accordingly, fifty primary and permanent molars with dentinal carious lesions were excavated using this technique of caries removal. The chemo-mechanical caries removal technique using Carisolv proved to be an effective atraumatic treatment modality with potential interest for use in clinical pediatric dentistry.

  8. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  9. T Plant removal of PWR Chiller Subsystem

    International Nuclear Information System (INIS)

    Dana, C.M.

    1994-01-01

    The PWR Pool Chiller System is not longer required for support of the Shippingport Blanket Fuel Assemblies Storage. The Engineering Work Plan will provide the overall coordination of the documentation and physical changes to deactivate the unneeded subsystem. The physical removal of all energy sources for the Chiller equipment will be covered under a one time work plan. The documentation changes will be covered using approved Engineering Change Notices and Procedure Change Authorizations as needed

  10. A metabolic model for members of the genus Tetrasphaera involved in enhanced biological phosphorus removal

    DEFF Research Database (Denmark)

    Kristiansen, Rikke; Nguyen, Hien Thi Thu; Saunders, Aaron Marc

    2013-01-01

    Members of the genus Tetrasphaera are considered to be putative polyphosphate accumulating organisms (PAOs) in enhanced biological phosphorus removal (EBPR) from wastewater. Although abundant in Danish full-scale wastewater EBPR plants, how similar their ecophysiology is to ‘Candidatus Accumuliba......Members of the genus Tetrasphaera are considered to be putative polyphosphate accumulating organisms (PAOs) in enhanced biological phosphorus removal (EBPR) from wastewater. Although abundant in Danish full-scale wastewater EBPR plants, how similar their ecophysiology is to ‘Candidatus....... japonica and T. elongata. Based on the models, we propose that under anaerobic conditions the Tetrasphaerarelated PAOs take up glucose and ferment this to succinate and other components. They also synthesize glycogen as a storage polymer, using energy generated from the degradation of stored polyphosphate...... by ‘Candidatus Accumulibacter phosphatis’, and reveals Tetrasphaera populations to be unusual and physiologically versatile PAOs carrying out denitrification, fermentation and polyphosphate accumulation....

  11. Office-based procedures for diagnosis and treatment of esophageal pathology.

    Science.gov (United States)

    Wellenstein, David J; Schutte, Henrieke W; Marres, Henri A M; Honings, Jimmie; Belafsky, Peter C; Postma, Gregory N; Takes, Robert P; van den Broek, Guido B

    2017-09-01

    Diagnostic and therapeutic office-based procedures under topical anesthesia are emerging in the daily practice of laryngologists and head and neck surgeons. Since the introduction of the transnasal esophagoscope, office-based procedures for the esophagus are increasingly performed. We conducted a systematic review of literature on office-based procedures under topical anesthesia for the esophagus. Transnasal esophagoscopy is an extensively investigated office-based procedure. This procedure shows better patient tolerability and equivalent accuracy compared to conventional transoral esophagoscopy, as well as time and cost savings. Secondary tracheoesophageal puncture, esophageal dilatation, esophageal sphincter injection, and foreign body removal are less investigated, but show promising results. With the introduction of the transnasal esophagoscope, an increasing number of diagnostic and therapeutic office-based procedures for the esophagus are possible, with multiple advantages. Further investigation must prove the clinical feasibility and effectiveness of the therapeutic office-based procedures. © 2017 Wiley Periodicals, Inc.

  12. To remove or not to remove? The challenge of extracting the template to make the cavities available in Molecularly Imprinted Polymers (MIPs).

    Science.gov (United States)

    Lorenzo, Rosa A; Carro, Antonia M; Alvarez-Lorenzo, Carmen; Concheiro, Angel

    2011-01-01

    Template removal is a critical step in the preparation of most molecularly imprinted polymers (MIPs). The polymer network itself and the affinity of the imprinted cavities for the template make its removal hard. If there are remaining template molecules in the MIPs, less cavities will be available for rebinding, which decreases efficiency. Furthermore, if template bleeding occurs during analytical applications, errors will arise. Despite the relevance to the MIPs performance, template removal has received scarce attention and is currently the least cost-effective step of the MIP development. Attempts to reach complete template removal may involve the use of too drastic conditions in conventional extraction techniques, resulting in the damage or the collapse of the imprinted cavities. Advances in the extraction techniques in the last decade may provide optimized tools. The aim of this review is to analyze the available data on the efficiency of diverse extraction techniques for template removal, paying attention not only to the removal yield but also to MIPs performance. Such an analysis is expected to be useful for opening a way to rational approaches for template removal (minimizing the costs of solvents and time) instead of the current trial-and-error methods.

  13. Population dynamics of bacteria involved in enhanced biological phosphorus removal in Danish wastewater treatment plants.

    Science.gov (United States)

    Mielczarek, Artur Tomasz; Nguyen, Hien Thi Thu; Nielsen, Jeppe Lund; Nielsen, Per Halkjær

    2013-03-15

    The enhanced biological phosphorus removal (EBPR) process is increasingly popular as a sustainable method for removal of phosphorus (P) from wastewater. This study consisted of a comprehensive three-year investigation of the identity and population dynamics of polyphosphate-accumulating organisms (PAOs) and glycogen-accumulating organisms (GAOs) in 28 Danish municipal wastewater treatment plants with nutrient removal. Fluorescence in situ hybridization was applied to quantify ten probe-defined populations of PAO and GAO that in total constituted a large fraction (30% on average) of the entire microbial community targeted by the EUBmix probes. Two PAO genera, Accumulibacter and Tetrasphaera, were very abundant in all EBPR plants (average of 3.7% and 27% of all bacteria, respectively), and their abundance was relatively stable in the Danish full-scale plants without clear temporal variations. GAOs were occasionally present in some plants (Competibacter in 11 plants, Defluviicoccus in 6 plants) and were consistent in only a few plants. This shows that these were not core species in the EBPR communities. The total GAO abundance was always lower than that of Accumulibacter. In plants without EBPR design, the abundance of PAO and GAO was significantly lower. Competibacter correlated in general with high fraction of industrial wastewater. In specific plants Accumulibacter correlated with high C/P ratio of the wastewater and Tetrasphaera with high organic loading. Interestingly, the relative microbial composition of the PAO/GAO species was unique to each plant over time, which gives a characteristic plant-specific "fingerprint". Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Dynamics of epiretinal membrane removal off the retinal surface: a computer simulation project.

    Science.gov (United States)

    Dogramaci, Mahmut; Williamson, Tom H

    2013-09-01

    To use a computer simulation to discern the safest angle at which to peel epiretinal membranes. We used ANSYS V.14.1 software to analyse the dynamics involved in membrane removal off the retinal surface. The geometrical values were taken from optical coherence tomography of 30 eyes with epiretinal membranes. A range of Young's modulus values of 0.03, 0.01 and 0.09 MPa were assigned to the epiretinal membrane and to the retina separately. The ratio of maximum shear stress (MSS) recorded at the attachment pegs over that recorded at the membrane (P/E ratio) was determined at nine displacement angles (DA). Mean MSS values recorded at the attachment pegs, epiretinal membrane and retina were significantly different at 0.8668, 0.6091 and 0.0017 Pa consecutively (p<0.05). There was a significant negative linear correlation between DA and MSS recorded at the epiretinal membrane when the Young's modulus for the epiretinal membrane was higher than or equal to that for the attachment pegs and the retina. Nevertheless, there was a significant positive linear correlation between DA and P/E ratio when the Young's modulus for the epiretinal membrane was equal to or lower than that for the attachment pegs and the retina. Attachment pegs appear to be the most likely part to fail (tear) during removal procedures. Changing the direction at which the edge of the membrane is pulled can relocate the MSS within in the tissue complex. Safer and effective removal could be achieved by pulling epiretinal membranes onto themselves at 165° DA.

  15. Developing, adopting and adapting operating procedures

    International Nuclear Information System (INIS)

    Rabouhams, J.

    1986-01-01

    This lecture specifies all the dispositions which have been taken by EDF Nuclear and Fossil Generation Department - according to the fact that availability and safety largely depend on the quality of the procedures and their easy handling - in order to develop, adopt and adapt the operating procedures. The following points are treated: General organization of procedures for plant operation during normal and abnormal conditions; Personnel and extend of responsibility involved into the development of procedures (research center, training center, specialized services, nuclear station, etc.); Validation of the procedures by means of full-scope simulators; Modifications of the procedures taking into account operation experience in material and human fields; Development of simulation softs in order to perform the procedures in abnormal situations; Evolution of operating technics and future skills. (orig.)

  16. Sialendoscope-assisted transoral removal of hilo-parenchymal sub-mandibular stones: surgical results and subjective scores.

    Science.gov (United States)

    Capaccio, P; Gaffuri, M; Rossi, V; Pignataro, L

    2017-04-01

    It has been suggested that a conservative trans-oral approach to proximal and hilo-parenchymal submandibular stones (HPSMS) is a valid alternative to the more frequently used sialadenectomy. The aim of this study was to evaluate the surgical, ultrasonographic and patients' subjective outcomes of results of the trans-oral removal of HPSMS. Between January 2003 and September 2015, sialendoscope-assisted trans-oral surgery was used to remove symptomatic, large (> 7 mm), fixed and palpable HPSMS from 479 patients under general anaesthesia. All patients were followed clinically and ultrasonographically to investigate symptom relief and recurrence of stones, and were telephonically interviewed to assess saliva-related subjective outcomes with a questionnaire. Stones were successfully removed from 472 patients (98.5%); the seven failures (1.5%) concerned pure parenchymal stones. One year after the procedure, 408 patients (85.1%) were symptom free, 59 (12.3%) had recurrent obstructive symptoms and 12 (2.6%) had recurrent infections. Of the 54 patients who developed a recurrent stone (11.2%), 52 underwent a second procedure: 29 interventional sialendoscopies, two sialendoscope-assisted intra-corporeal pneumatic lithotripsy, eight secondary transoral surgery to remove residual stones, six a cycle of extra-corporeal lithotripsy and seven submandibular sialadenectomy. Most patients (75.2%) reported mild surgery-related pain. The symptoms of 454 patients (94.8%) improved after adjunctive treatment and, at the end of follow-up, the affected gland was preserved in 98.5% of patients. A sialendoscope-assisted trans-oral removal of large HPSMS is a safe, effective, conservative surgical procedure, and functional preservation of the main duct and parenchyma of the obstructed gland allows sialendoscopic access through the natural ostium in case of recurrence. Combining a trans-oral approach with other minimally invasive, conservative procedures ensures symptomatic relief and salivary

  17. Shadow detection and removal in RGB VHR images for land use unsupervised classification

    Science.gov (United States)

    Movia, A.; Beinat, A.; Crosilla, F.

    2016-09-01

    Nowadays, high resolution aerial images are widely available thanks to the diffusion of advanced technologies such as UAVs (Unmanned Aerial Vehicles) and new satellite missions. Although these developments offer new opportunities for accurate land use analysis and change detection, cloud and terrain shadows actually limit benefits and possibilities of modern sensors. Focusing on the problem of shadow detection and removal in VHR color images, the paper proposes new solutions and analyses how they can enhance common unsupervised classification procedures for identifying land use classes related to the CO2 absorption. To this aim, an improved fully automatic procedure has been developed for detecting image shadows using exclusively RGB color information, and avoiding user interaction. Results show a significant accuracy enhancement with respect to similar methods using RGB based indexes. Furthermore, novel solutions derived from Procrustes analysis have been applied to remove shadows and restore brightness in the images. In particular, two methods implementing the so called "anisotropic Procrustes" and the "not-centered oblique Procrustes" algorithms have been developed and compared with the linear correlation correction method based on the Cholesky decomposition. To assess how shadow removal can enhance unsupervised classifications, results obtained with classical methods such as k-means, maximum likelihood, and self-organizing maps, have been compared to each other and with a supervised clustering procedure.

  18. Electrocoagulation-Adsorption to Remove Anionic and Cationic Dyes from Aqueous Solution by PV-Energy

    OpenAIRE

    Castañeda-Díaz, J.; Pavón-Silva, T.; Gutiérrez-Segura, E.; Colín-Cruz, A.

    2017-01-01

    The cationic dye malachite green (MG) and the anionic dye Remazol yellow (RY) were removed from aqueous solutions using electrocoagulation-adsorption processes. Batch and continuous electrocoagulation procedures were performed and compared. Carbonaceous materials obtained from industrial sewage sludge and commercial activated carbons were used to adsorb dyes from aqueous solutions in column systems with a 96–98% removal efficiency. The continuous electrocoagulation-adsorption system was more ...

  19. Automated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA.

    Science.gov (United States)

    Sai, Chong Yeh; Mokhtar, Norrima; Arof, Hamzah; Cumming, Paul; Iwahashi, Masahiro

    2018-05-01

    Brain electrical activity recordings by electroencephalography (EEG) are often contaminated with signal artifacts. Procedures for automated removal of EEG artifacts are frequently sought for clinical diagnostics and brain-computer interface applications. In recent years, a combination of independent component analysis (ICA) and discrete wavelet transform has been introduced as standard technique for EEG artifact removal. However, in performing the wavelet-ICA procedure, visual inspection or arbitrary thresholding may be required for identifying artifactual components in the EEG signal. We now propose a novel approach for identifying artifactual components separated by wavelet-ICA using a pretrained support vector machine (SVM). Our method presents a robust and extendable system that enables fully automated identification and removal of artifacts from EEG signals, without applying any arbitrary thresholding. Using test data contaminated by eye blink artifacts, we show that our method performed better in identifying artifactual components than did existing thresholding methods. Furthermore, wavelet-ICA in conjunction with SVM successfully removed target artifacts, while largely retaining the EEG source signals of interest. We propose a set of features including kurtosis, variance, Shannon's entropy, and range of amplitude as training and test data of SVM to identify eye blink artifacts in EEG signals. This combinatorial method is also extendable to accommodate multiple types of artifacts present in multichannel EEG. We envision future research to explore other descriptive features corresponding to other types of artifactual components.

  20. Test Plan for the overburden removal demonstration

    International Nuclear Information System (INIS)

    Rice, P.; Thompson, D.; Winberg, M.; Skaggs, J.

    1993-06-01

    The removal of soil overburdens from contaminated pits and trenches involves using equipment that will remove a small layer of soil from 3 to 6 in. at any time. As a layer of soil is removed, overburden characterization techniques perform surveys to a depth that exceeds each overburden removal layer to ensure that the removed soil will be free of contamination. It is generally expected that no contamination will be found in the soil overburden, which was brought in after the waste was put in place. It is anticipated that some containers in the waste zone have lost their integrity, and the waste leakage from those containers has migrated by gravity downward into the waste zone. To maintain a safe work environment, this method of overburden removal should allow safe preparation of a pit or trench for final remediation. To demonstrate the soil overburden techniques, the Buried Waste Integrated Demonstration Program has contracted vendor services to provide equipment and techniques demonstrating soil overburden removal technology. The demonstration will include tests that will evaluate equipment performance and techniques for removal of overburden soil, control of contamination spread, and dust control. To evaluate the performance of these techniques, air particulate samples, physical measurements of the excavation soil cuts, maneuverability measurements, and time versus volume (rate) of soil removal data will be collected during removal operations. To provide a medium for sample evaluation, the overburden will be spiked at specific locations and depths with rare earth tracers. This test plan will be describe the objectives of the demonstration, data quality objectives, methods to be used to operate the equipment and use the techniques in the test area, and methods to be used in collecting data during the demonstration

  1. Experience with antimony activity removal process in Indian PHWRs

    International Nuclear Information System (INIS)

    Velmurugan, S.; Mittal, Vinit K.; Kumbhar, A.G.; Narasimhan, S.V.; Bhat, H.R.; Krishna Rao, K.S.; Upadhyay, S.K.; Jain, A.K.

    2008-01-01

    The problem of antimony (Sb) activity during decontamination was first encountered in NAPS-1 and Sb activity deposition took place during the decontamination resulting in poor decontamination factors (DF). Sb problem has been observed in PWRs and PHWRs elsewhere also. These utilities use an oxidative process involving the addition of H 2 O 2 to remove these Sb activities from the core and remove it on ion exchange resins. Experience in CANDU PHWRs indicated disappearance of H 2 O 2 in quantities higher than that observed in PWRs. This is attributed to the higher pick-up of H 2 O 2 by the magnetite/ferrites over large carbon steel surface present in the primary coolant system of PHWRs. Systematic work was carried out to understand the deposition of Sb on PHT system surfaces and a new method was evolved to remove the Sb activities from the system. This alternative reductive chemical process involve the addition of Nitrilo Tri Acetic Acid, Citric Acid and Rodine-92B and circulating the chemicals for a short period and then the Sb and other activities released from the core are removed by the mixed bed. Subsequent to the Sb removal process, the normal chemical decontamination of the system is carried out to remove 60 Co and other activities. This non-oxidizing Sb removal process was applied to NAPS-2 primary system prior to EMCCR. During this Sb removal process of NAPS-2, around 450 μCi/L activity of 124 Sb was released from the system surfaces to the formulation. Activity measurement in the samples collected and the on-line radiation field data indicated that deposition of Sb activities on system surfaces has been prevented by Rodine-92B and subsequently these activities have been removed by mixed bed IX columns. Antimony removal process worked successfully, but in the second normal decontamination process around 150 μCi/L activities came in the formulation which was not anticipated. As a result DF observed immediately after the decontamination campaign was not good

  2. MITS Feed and Withdrawal Subsystem: operating procedures

    International Nuclear Information System (INIS)

    Brown, W.S.

    1980-01-01

    This procedure details the steps involved in establishing closed loop flows, providing UF 6 vapor to the FEED header of the Sampling Subsystem and returning it through the PRODUCT and TAILS headers via the F and W recycle valves. It is essentially a Startup Procedure

  3. Hydrocarbon removal with constructed wetlands

    OpenAIRE

    Eke, Paul Emeka

    2008-01-01

    Wetlands have long played a significant role as natural purification systems, and have been effectively used to treat domestic, agricultural and industrial wastewater. However, very little is known about the biochemical processes involved, and the use of constructed treatment wetlands in the removal of petroleum aromatic hydrocarbons from produced and/or processed water. Wastewaters from the oil industry contain aromatic hydrocarbons such as benzene, toluene, ethylbenzene and x...

  4. Flexible endoscopic procedure in children with foreign bodies in their upper gastrointestinal system

    Directory of Open Access Journals (Sweden)

    Kaan Demirören

    2014-03-01

    Full Text Available Objective: Foreign body ingestion is an important public health problem. We pointed to this subject and aimed to determine the effectiveness of flexible endoscopic procedure in this study. Methods: We evaluated retrospectively fifty children having foreign body in their upper gastrointestinal system, who underwent flexible endoscopic procedure. Results: Of the patients, mean age was 5.5 ± 4 years old (range: 0.5-16 years, 64% was female. Ingested foreign bodies were coin (58%, pin (10%, battery (6%, nail (6%, necklace (6%, safety pin (4% and sewing pin, wire hairclip, ring, button and chicken skin. In endoscopic procedure, foreign bodies were seen in upper esophagus (32%, middle esophagus (26%, lower esophagus (8%, stomach (18%, bulbus (4% and second part of duodenum (8%, but were not seen in 4% of the cases. While 94% of foreign bodies were endoscopically removed, 6% of them were pushed to stomach with gastroscope from esophagus and left for spontaneous passage. Any important complication was developed. Conclusion: Flexible endoscopic procedure is an effective and safe method for removal of gastrointestinal system foreign bodies in children.

  5. Effectiveness of percutaneous biliary stone removal as primary treatment in case with difficulties in the use of an endoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sin Ae; Han, Young Min; Jin, Gong Yong; Lee, Seung Ok; Yu, Hee Chul [Chonbuk National University Medical School and Hospital, Jeonju(Korea, Republic of)

    2014-03-15

    To evaluate the effectiveness of percutaneous biliary stone removal as a primary treatment in cases with difficulties to use an endoscopy. From March 2004 to May 2011, 17 patients who underwent primary percutaneous biliary stone removal (Group 1) and 34 case-matched patients who underwent primary endoscopic biliary stone removal were selected (Group 2). The inclusion criteria were as follows: patients who had 1) ≥ 15 mm bile duct stones, 2) intrahepatic bile duct stones, 3) bile duct stones with a history of previous gastrointestinal bypass surgery. In the present study were analyzed the success rates, the length of postprocedural hospital stay, the change of Amylase/Lipase values and complications post procedure. Statistical analysis was performed using paired t-test and unpaired t-test. The success rate was higher in Group 1 (94.1%) than in Group 2 (85.3%). Length of post procedural hospital stay and the post procedural amylase level were significantly increased in Group 2 (p = 0.036 and p = 0.017, respectively). In cases of bile duct stones with difficulties in the use of an endoscopy a percutaneous biliary stone removal can be efficient as a primary treatment.

  6. Study of removal of Direct Yellow 12 by cadmium oxide nanowires loaded on activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, Mehrorang, E-mail: m_ghaedi@mail.yu.ac.ir [Chemistry Department, Yasouj University Yasouj 75914-35 (Iran, Islamic Republic of); Sadeghian, Batuol [Chemistry Department, Yasouj University Yasouj 75914-35 (Iran, Islamic Republic of); Kokhdan, Syamak Nasiri, E-mail: syamak.nasiri@yahoo.com [Chemistry Department, Yasouj University Yasouj 75914-35 (Iran, Islamic Republic of); Pebdani, Arezou Amiri [Chemistry Department, Yasouj University Yasouj 75914-35 (Iran, Islamic Republic of); Sahraei, Reza; Daneshfar, Ali; Mihandoost, Asma [Department of Chemistry, University of Ilam, P.O. Box: 65315-516, Ilam (Iran, Islamic Republic of)

    2013-05-01

    In this research, cadmium oxide nanowires loaded on activated carbon (CdO-NW-AC) has been synthesized by a simple procedure and characterized by different techniques such as XRD, SEM and UV–vis spectrometry. This new adsorbent has been efficiently utilized for the removal of the Direct Yellow 12 (DY-12) from wastewater. To obtain maximum DY-12 removal efficiency, the influences of variables such as pH, DY-12 concentration, amount of CdO-NW-AC, contact time, and temperature have been examined and optimized in a batch method. Following the variable optimization, the experimental equilibrium data (at different concentration of DY-12) was fitted to conventional isotherm models such as Langmuir, Freundlich and Tempkin. The applicability of each method is based on the R{sup 2} and error analysis for each model. It was found that the experimental equilibrium data well fitted to the Langmuir isotherm model. The dependency of removal process to time and the experimental data follow second order kinetic model with involvement of intraparticle diffusion model. The negative value of Gibbs's free energy and positive value of adsorption enthalpy show the spontaneous and endothermic nature of adsorption process. - Graphical abstract: Typical FE-SEM image of the CdO nanowires. Highlights: ► Cadmium oxide nanowires loaded on activated carbon was utilized as an adsorbent. ► It was used for the removal of Direct Yellow 12 from aqueous solutions. ► The adsorption of Direct Yellow 12 on this adsorbent is endothermic in nature. ► The adsorption equilibrium data was well described by the Langmuir isotherm model.

  7. Pilot study points way to iron/manganese removal

    Energy Technology Data Exchange (ETDEWEB)

    Qureshi, N.; Barnes, A. [Progressive Consulting Engineers Inc., Minneapolis, MN (United States)

    1994-12-31

    The use of coal, greensand and sand in filters for removing iron and manganese from the Brooklyn Park, Minnesota, water supply was investigated. The most effective and economic treatment involved using a dual media filtration and potassium permanganate as the oxidant.

  8. Impact of removable partial denture prosthesis on chewing efficiency

    Science.gov (United States)

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

  9. Evaluation of the radiation levels in different surgical procedures

    International Nuclear Information System (INIS)

    Silva Santos, M.C.P. da; Almeida, A. de; Belluci, A.D.; Ghilardi Neto, T.

    1989-01-01

    The exposure of a medical team to radiation during surgical procedures evidently depends on the duration and difficulties of the particular procedure. We have made a dosimetric study of the average equivalent doses received by the surgical teams during 10 different surgical procedures over a period of one month. Our results demonstrate that the levels of ionizing radiation that the members of the teams receive typically do not surpass the limits stipulated for the following surgical procedures: nefrolithotomy, percutaneous ureterolithomy, ureteroscoy connected with removal of stones in the inferior third of the ureter, osteosynthesis of the tibial plateau together with a articular toalet and minireconstruction of the knee. For compound surgical procedures, for example, osteosynthesis of a femur fracture together with biopsy of an exposed femur or percutaneous nefrolithotomy (complex cases), the dose limits have been surpassed owing to the additional fluoroscopy needed in those p rocedures. (author) [pt

  10. Endovascular Removal of Fractured Inferior Vena Cava Filter Fragments: 5-Year Registry Data with Prospective Outcomes on Retained Fragments.

    Science.gov (United States)

    Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T

    2018-06-01

    To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically

  11. DOT-7A packaging test procedure

    International Nuclear Information System (INIS)

    Kelly, D.L.

    1995-01-01

    This test procedure documents the steps involved with performance testing of Department of Transportation Specification 7A (DOT-7A) Type A packages. It includes description of the performance tests, the personnel involved, appropriate safety considerations, and the procedures to be followed while performing the tests. Westinghouse Hanford Company (WHC) is conducting the evaluation and testing discussed herein for the Department of Energy-Headquarters, Division of Quality Verification and Transportation Safety (EH-321). Please note that this report is not in WHC format. This report is being submitted through the Engineering Documentation System so that it may be used for reference and information purposes

  12. The effect of pylorus removal on delayed gastric emptying after pancreaticoduodenectomy: a meta-analysis of 2,599 patients.

    Directory of Open Access Journals (Sweden)

    Wenming Wu

    Full Text Available BACKGROUND: Delayed gastric emptying is a serious complication of pancreaticoduodenectomy. The effect of pylorus removal on delayed gastric emptying has not been well evaluated. STUDY DESIGN: We searched five databases (PubMed, EMBASE and the Cochrane Central Register of Controlled Trials, Scopus and Web of Science up to July 2014. The meta-regression analysis was performed to evaluate any factors accountable for the heterogeneity. Publication bias was assessed by Egger's test, and corrected by Duval's trim and fill method. Subgroup analyses were conducted for different surgical techniques of pyloric removal. Other intraoperative and postoperative parameters were compared between two groups. RESULTS: We included 27 studies involving 2,599 patients, with a moderate-high heterogeneity for primary outcome (I(2 = 63%. Meta-regression analysis showed that four variables primarily contributed to the heterogeneity, namely nasogastric tube intubation time, solid food start time, preoperative diabetes percentage and the number of patients in pylorus-preserving group. After excluding four studies, the remaining twenty-three studies showed reduced heterogeneity (I(2 = 51%. Then we used Duval's trim and fill method to correct publication bias. The corrected MH odds ratio was 0.78 (95% CI: 0.52-1.17. A subgroup analysis showed that pylorus removal tends to reduce delayed gastric emptying incidence for subtotal stomach-preserving pancreaticoduodenectomy or pylorus-resecting pancreaticoduodenectomy, compared with pylorus-preserving group. However, standard Whipple procedure failed to show any significant reduction of DGE compared with pylorus-removal group. No significant differences were observed in terms of length of hospital stay, infection and pancreatic fistula; however, pylorus removal resulted in longer operation time, more blood loss and higher mortality. CONCLUSION: The pylorus removal does not significantly reduce the overall incidence of delayed

  13. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Carroll, M.M.; Crooks, D.L.; Doyle, J.R.; Jeblick, H.G.; Kessel, D.S.; Tippy, M.W.; Stuckey, J.M.

    1981-03-01

    These procedures are written for activities that involve the use of explosives, dangerous chemicals, radioactive materials, hazardous sytems, and for certain types of operational facilities which present hazards. This guideline presents a suggested Safe Operating Procedures format

  14. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  15. Surface cleaning procedures for thin films of indium gallium nitride grown on sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Douglass, K.; Hunt, S. [Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716 (United States); Teplyakov, A., E-mail: andrewt@udel.edu [Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716 (United States); Opila, R.L. [Department of Material Science and Engineering, University of Delaware, Newark, DE 19716 (United States)

    2010-12-15

    Surface preparation procedures for indium gallium nitride (InGaN) thin films were analyzed for their effectiveness for carbon and oxide removal as well as for the resulting surface roughness. Aqua regia (3:1 mixture of concentrated hydrochloric acid and concentrated nitric acid, AR), hydrofluoric acid (HF), hydrochloric acid (HCl), piranha solution (1:1 mixture of sulfuric acid and 30% H{sub 2}O{sub 2}) and 1:9 ammonium sulfide:tert-butanol were all used along with high temperature anneals to remove surface contamination. X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were utilized to study the extent of surface contamination and surface roughness, respectively. The ammonium sulfide treatment provided the best overall removal of oxygen and carbon. Annealing over 700 deg. C after a treatment showed an even further improvement in surface contamination removal. The piranha treatment resulted in the lowest residual carbon, while the ammonium sulfide treatment leads to the lowest residual oxygen. AFM data showed that all the treatments decreased the surface roughness (with respect to as-grown specimens) with HCl, HF, (NH{sub 4}){sub 2}S and RCA procedures giving the best RMS values ({approx}0.5-0.8 nm).

  16. Bacteriological study and structural composition of staghorn stones removed by the anatrophic nephrolithotomic procedure

    Directory of Open Access Journals (Sweden)

    Hamid Shafi

    2013-01-01

    Full Text Available This study was conducted to determine the composition of staghorn stones and to assess the proportion of infected stones as well as the correlation between infection in the stones and bacteria grown in urine. Samples of 45 consecutive stones removed through anatrophic nephrolithotomic procedures were taken from the operation site and samples of urine were obtained by simultaneous bladder catheterization. The frequency of infection in the stones and correlation between infection of stone and urine samples were determined with respect to the composition of the stones. Twenty-two males and 23 females, with respective mean ages of 48.3 ± 15.6 years and 51 ± 7.4 years, were studied. The stone and urine cultures yielded positive results in ten and 16 patients, respectively, of a total of 45 patients (22.2% and 35.5%, respectively. Calcium oxalate was the main constituent of staghorn stones, seen in 31 patients (68.8%, uric acid in 12 patients (26.6% and struvite and/or calcium phosphate in 11 patients (24.4%. In seven of ten stones with bacterial growth, bacteria were isolated from urine cultures as well, which accounted for a concordance rate of 70%. The bacteria grown in the stone were the cause of urinary tract infection (UTI in 43.5% of the cases. Stone infection was significantly associated with UTI (OR = 6.47; 95% CI 1.43-31.7, P = 0.021 and presence of phosphate in the stones (OR = 18, 95% CI 3.28-99.6, P = 0.0006. E. coli was the most common bacteria grown from the stones, and was isolated in 50% of the cases; Ureaplasma urealyticum was the most common organism causing UTI, grown in 62.5% of the urine samples. There was a high concordance rate between bacteria in the stones and urine. These findings indicate that the urine culture can provide information for selection of an appropriate anti-microbial agent for stone sterilization. In addition, preventing re-growth or recurrence of stones and treatment of post-surgical infections would be

  17. OSL sensitivity changes during single aliquot procedures: Computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Agersnap Larsen, N.; Bøtter-Jensen, L.

    1997-01-01

    We present computer simulations of sensitivity changes obtained during single aliquot, regeneration procedures. The simulations indicate that the sensitivity changes are the combined result of shallow trap and deep trap effects. Four separate processes have been identified. Although procedures can...... be suggested to eliminate the shallow trap effects, it appears that the deep trap effects cannot be removed. The character of the sensitivity changes which result from these effects is seen to be dependent upon several external parameters, including the extent of bleaching of the OSL signal, the laboratory...

  18. Evaluation of the dual staining technique for complete removal of idiopathic epimacular membranes

    Directory of Open Access Journals (Sweden)

    Ahmed M Abdel Hadi

    2015-01-01

    In conclusion, dual staining starting with TA effectively led to adequate visualization and removal of the posterior hyaloid as well as the fibrous component of the idiopathic EMM. The subsequent BBG administration in an air filled vitreous (the dry technique helped selective removal of the ILM with no deleterious effects on the functional or the anatomical outcomes of the procedure as demonstrated by the significant improvement in both the BCVA and the CMT 6 months after surgery.

  19. A Geometrical-Statistical Approach to Outlier Removal for TDOA Measurements

    Science.gov (United States)

    Compagnoni, Marco; Pini, Alessia; Canclini, Antonio; Bestagini, Paolo; Antonacci, Fabio; Tubaro, Stefano; Sarti, Augusto

    2017-08-01

    The curse of outlier measurements in estimation problems is a well known issue in a variety of fields. Therefore, outlier removal procedures, which enables the identification of spurious measurements within a set, have been developed for many different scenarios and applications. In this paper, we propose a statistically motivated outlier removal algorithm for time differences of arrival (TDOAs), or equivalently range differences (RD), acquired at sensor arrays. The method exploits the TDOA-space formalism and works by only knowing relative sensor positions. As the proposed method is completely independent from the application for which measurements are used, it can be reliably used to identify outliers within a set of TDOA/RD measurements in different fields (e.g. acoustic source localization, sensor synchronization, radar, remote sensing, etc.). The proposed outlier removal algorithm is validated by means of synthetic simulations and real experiments.

  20. Method for removing trace contaminants from multicurie amounts of 144Ce

    International Nuclear Information System (INIS)

    Wagner, J.A.; Kanapilly, G.M.

    1976-01-01

    Removal of contaminants from stock solutions of 144 Ce(III) was required for large quantities of 144 Ce prior to incorporation into fused aluminosilicate particles for inhalation toxicology studies. Since available procedures for purification of 144 Ce could not be readily adapted to our laboratory conditions and requirements, a simple procedure was developed to purify 144 Ce in multicurie quantities of 144 Ce(III). This procedure consists of separation of 144 Ce from contaminants by precipitation and filtrations at different pH. Its simplicity and efficacy in providing a stock solution that would readily exchange into montmorillonite clay was demonstrated when it was used during the preparation of large amounts of 144 Ce in fused aluminosilicate particles

  1. Darwin's Avatars: a Novel Combination of Gameplay and Procedural Content Generation

    DEFF Research Database (Denmark)

    Lessin, Dan; Risi, Sebastian

    2015-01-01

    of gameplay and content generation, a proof-of-concept game—tentatively titled Darwin’s Avatars—was implemented using evolved creature content, and user tested. This implementation also provided a unique opportunity to compare human and evolved control of evolved virtual creatures, both qualitatively......The co-evolution of morphology and control for virtual creatures enables the creation of a novel form of gameplay and procedural content generation. Starting with a creature evolved to perform a simple task such as locomotion and removing its brain, the remaining body can be employed...... of this challenge is inexhaustible, since the evolution of virtual creatures provides a way to procedurally generate content for such a game. An endless series of creatures can be evolved for a task, then have their brains removed to become the game’s next human-control challenge. To demonstrate this new form...

  2. Clinical use of a 15-W diode laser in small animal surgery: results in 30 varied procedures

    Science.gov (United States)

    Crowe, Dennis T.; Swalander, David; Hittenmiller, Donald; Newton, Jenifer

    1999-06-01

    The use of a 15-watt diode laser (CeramOptec)in 30 surgical procedures in dogs and cats was reviewed. Ease of use, operator safety, hemostasis control, wound healing, surgical time, complication rate, and pain control were observed and recorded. Procedures performed were partial pancreatectomy, nasal carcinoma ablation, medial meniscus channeling, perianal and anorectal mass removal (5), hemangioma and hemangiopericytoma removal from two legs, benign skin mass removal (7), liver lobectomy, partial prostatectomy, soft palate resection, partial arytenoidectomy, partial ablation of a thyroid carcinoma, photo-vaporization of the tumor bed following malignant tumor resection (4), neurosheath tumor removal from the tongue, tail sebaceous cyst resection, malignant mammary tumor and mast cell tumor removal. The laser was found to be very simple and safe to use. Hemostasis was excellent in all but the liver and prostate surgeries. The laser was particularly effective in preventing hemorrhage during perianal, anal, and tongue mass removal. It is estimated that a time and blood loss savings of 50% over that of conventional surgery occurred with the use of the laser. All external wounds made by laser appeared to heal faster and with less inflammation than those made with a conventional or electrosurgical scalpel.

  3. Argon analytical procedures for potassium-argon dating

    International Nuclear Information System (INIS)

    Gabites, J.E.; Adams, C.J.

    1981-01-01

    A manual for the argon analytical methods involved in potassium-argon geochronology, including: i) operating procedures for the ultra-high vacuum argon extraction/purification equipment for the analysis of nanolitre quantities of radiogenic argon in rocks, minerals and gases; ii) operating procedures for the AEI-MS10 gas source mass spectrometer

  4. The Social, Historical, and Institutional Contingencies of Dam Removal

    Science.gov (United States)

    Magilligan, F. J.; Sneddon, C. S.; Fox, C. A.

    2017-06-01

    Environmental managers in the United States and elsewhere are increasingly perceiving dam removal as a critical tool for river restoration and enhancing watershed resilience. In New England, over 125 dams have been dismantled for ecological and economic rationales. A surprising number of these removals, including many that are ongoing, have generated heated conflicts between restoration proponents and local communities who value their dammed landscapes. Using a comparative case study approach, we examine the environmental conflict around efforts to remove six dams in New England. Each of these removal efforts followed quite different paths and resultant outcomes: successful removal, stalled removal, and failure despite seemingly favorable institutional conditions. Lengthy conflicts often transpired in instances where removals occurred, but these were successfully arbitrated by paying attention to local historical-geographical conditions conducive to removal and by brokering effective compromises between dam owners and the various local actors and stakeholders involved in the removal process. Yet our results across all cases suggest that these are necessary, but not sufficient conditions for restoration through dam removal since a similar set of conditions typified cases where removals are continuously stalled or completely halted. Scholars examining the intersection between ecological restoration and environmental politics should remain vigilant in seeking patterns and generalities across cases of environmental conflict in order to promote important biophysical goals, but must also remain open to the ways in which those goals are thwarted and shaped by conflicts that are deeply contingent on historical-geographical conditions and broader institutional networks of power and influence.

  5. The Social, Historical, and Institutional Contingencies of Dam Removal.

    Science.gov (United States)

    Magilligan, F J; Sneddon, C S; Fox, C A

    2017-06-01

    Environmental managers in the United States and elsewhere are increasingly perceiving dam removal as a critical tool for river restoration and enhancing watershed resilience. In New England, over 125 dams have been dismantled for ecological and economic rationales. A surprising number of these removals, including many that are ongoing, have generated heated conflicts between restoration proponents and local communities who value their dammed landscapes. Using a comparative case study approach, we examine the environmental conflict around efforts to remove six dams in New England. Each of these removal efforts followed quite different paths and resultant outcomes: successful removal, stalled removal, and failure despite seemingly favorable institutional conditions. Lengthy conflicts often transpired in instances where removals occurred, but these were successfully arbitrated by paying attention to local historical-geographical conditions conducive to removal and by brokering effective compromises between dam owners and the various local actors and stakeholders involved in the removal process. Yet our results across all cases suggest that these are necessary, but not sufficient conditions for restoration through dam removal since a similar set of conditions typified cases where removals are continuously stalled or completely halted. Scholars examining the intersection between ecological restoration and environmental politics should remain vigilant in seeking patterns and generalities across cases of environmental conflict in order to promote important biophysical goals, but must also remain open to the ways in which those goals are thwarted and shaped by conflicts that are deeply contingent on historical-geographical conditions and broader institutional networks of power and influence.

  6. Removal of Retained Adherent Placental Remnants Using the Hysteroscopy Endo-Operative System.

    Science.gov (United States)

    Zhu, Ke-An; Huang, Huan; Xue, Min; Subedi, Jigyasa; Jamail, Grace; Zhao, Weidong; Xu, Dabao; Xiao, Songshu

    2016-01-01

    Removal of retained adherent placental remnants (RAPRs) may be challenging using traditional 5Fr or 7Fr hysteroscopic grasping forceps because they are very small. This is particularly true when the retained placental remnant is large. This video demonstrates the advantages of using the Hysteroscopy Endo-Operative System (HEOS), a specially designed operative hysteroscope with a 13Fr working channel, to remove retained placental remnants. Step-by-step explanation of the technique using videos and pictures (educative video) (Canadian Task Force Classification III). Third Xiangya Hospital of Central South University, Hunan, China. A 32-year-old woman was diagnosed with RAPRs 5 weeks after the evacuation of retained placenta after a spontaneous abortion at 16 weeks' gestation. Gynecologic examination revealed an anterior 8-week uterus and no tenderness. Serum β-human chorionic gonadotropin was 150 mIU/L. Sonography revealed an irregular intrauterine mass, 3.5 cm × 3.5 cm × 3 cm in size. Removal of RAPRs using HEOS (Sopro-comeg Company, Bordeaux, France). The operation time was only 12 minutes. The RAPRs were removed completely and quickly in 1 procedure with no complications. The serum β-human chorionic gonadotropin titer normalized 1 week after the procedure. This study was approved by the institutional review board of the Third Xiangya Hospital of Central South University. When indicated, removal of RAPRs using HEOS is safe and simple because of its large and strong cold forceps. Additionally, it avoids electrical and thermal injury to the endometrium, which is particularly important in a population that wants to preserve fertility. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  7. Radiation exposure of operator during various interventional procedures

    International Nuclear Information System (INIS)

    Yu, In Kyu; Chung, Jin Wook; Han, Joon Koo; Park, Jae Hyung; Kang, Wee Saing

    1994-01-01

    To investigate the levels of radiation exposure of an operator which may be influenced by the wearing an apron, type of procedure, duration of fluoroscopy and operator's skill during various interventional procedures. Radiation doses were measured both inside and outside the apron(0.5 mm lead equivalent) of the operator by a film badge monitoring method and the duration of fluoroscopy was measured in 96 procedures prospectively. The procedures were 30 transcatheter arterial embolization (TAE), 25 percutaneous transhepatic biliary drainages (PTBD), 16 stone removals (SR), 15 percutaneous needle aspirations (PNCA) and 10 percutaneous nephrostomies(PCN). To assess the difference of exposure by the operator's skill, the procedures of TAE and PTBD were done separately by groups of staffs and residents. Average protective effect of the apron was 72.8%. Average radiation exposure(unit: μ Sv/procedure was 23.3 in PTBD by residents, 10.0 in PTBD by staffs, 10.0 in SR, 8.7 in TAE by residents, 7.3 in TAE by staffs, 9.0 in PCN and 6.0 in PCNA. Average radiation exposure of residents were 1.9 times greater than those of staffs. Radiation exposure was not proportionally related to the duration of fluoroscopy, but influenced by wearing an apron, various types of procedure and operator's skills

  8. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  9. Method for the removal and recovery of mercury

    Science.gov (United States)

    Easterly, Clay E.; Vass, Arpad A.; Tyndall, Richard L.

    1997-01-01

    The present invention is an enhanced method for the removal and recovery of mercury from mercury-contaminated matrices. The method involves contacting a mercury-contaminated matrix with an aqueous dispersant solution derived from specific intra-amoebic isolates to release the mercury from the mercury-contaminated matrix and emulsify the mercury; then, contacting the matrix with an amalgamating metal from a metal source to amalgamate the mercury to the amalgamating metal; removing the metallic source from the mercury-contaminated matrix; and heating the metallic source to vaporize the mercury in a closed system to capture the mercury vapors.

  10. Management of anterior dental crossbite with removable appliances

    Directory of Open Access Journals (Sweden)

    Ayca Tuba Ulusoy

    2013-01-01

    Full Text Available This case report describes the treatment of an 8-year-old girl with anterior dental crossbite using a series of removable appliances to bring the teeth into a normal position. Clinical presentation and intervention: A removable acrylic appliance with a bite plate incorporating a screw was used to correct the anterior dental crossbite and align the incisors. The subsequent eruption of the maxillary left lateral incisor on the palatinal side was treated with a second acrylic plate incorporating a labiolingual spring. After an 8-month period, the anterior crossbite involving multiple incisors was corrected.

  11. THE VALUE OF REMOVING DAILY OBSTACLES VIA EVERYDAY PROBLEM SOLVING THEORY: DEVELOPING AN APPLIED NOVEL PROCEDURE TO INCREASE SELF-EFFICACY FOR EXERCISE

    Directory of Open Access Journals (Sweden)

    Daniele eArtistico

    2013-01-01

    Full Text Available The objective of the study was to develop a novel procedure to increase self-efficacy for exercise. Gains in one’s ability to resolve day-to-day obstacles for entering an exercise routine were expected to cause an increase in self-efficacy for exercise. Fifty-five sedentary participants (did not exercise regularly for at least 4 months prior to the study who expressed an intention to exercise in the near future were selected for the study. Participants were randomly assigned to one of three conditions: 1 an Experimental Group in which they received a problem-solving training session to learn new strategies for solving day-to-day obstacles that interfere with exercise, 2 a Control Group with Problem Solving Training which received a problem solving training session focused on a typical day-to-day problem unrelated to exercise, or 3 a Control Group which did not receive any problem-solving training. Assessment of obstacles to exercise and perceived self-efficacy for exercise were conducted at baseline; perceived self-efficacy for exercise was reassessed post-intervention (one week later. No differences in perceived challenges posed by obstacles to exercise or self-efficacy for exercise were observed across groups at baseline. The Experimental Group reported greater improvement in self-efficacy for exercise compared to the Control Group with Training (p < 0.01 and the Control Group (p < 0.01. Results of this study suggest that a novel procedure that focuses on removing obstacles to intended planned fitness activities is effective in increasing self-efficacy to engage in exercise among sedentary adults. Implications of these findings for use in applied settings and treatment studies are discussed.

  12. The Value of Removing Daily Obstacles via Everyday Problem-Solving Theory: Developing an Applied Novel Procedure to Increase Self-Efficacy for Exercise.

    Science.gov (United States)

    Artistico, Daniele; Pinto, Angela Marinilli; Douek, Jill; Black, Justin; Pezzuti, Lina

    2013-01-01

    The objective of the study was to develop a novel procedure to increase self-efficacy for exercise. Gains in one's ability to resolve day-to-day obstacles for entering an exercise routine were expected to cause an increase in self-efficacy for exercise. Fifty-five sedentary participants (did not exercise regularly for at least 4 months prior to the study) who expressed an intention to exercise in the near future were selected for the study. Participants were randomly assigned to one of three conditions: (1) an Experimental Group in which they received a problem-solving training session to learn new strategies for solving day-to-day obstacles that interfere with exercise, (2) a Control Group with Problem-Solving Training which received a problem-solving training session focused on a typical day-to-day problem unrelated to exercise, or (3) a Control Group which did not receive any problem-solving training. Assessment of obstacles to exercise and perceived self-efficacy for exercise were conducted at baseline; perceived self-efficacy for exercise was reassessed post-intervention (1 week later). No differences in perceived challenges posed by obstacles to exercise or self-efficacy for exercise were observed across groups at baseline. The Experimental Group reported greater improvement in self-efficacy for exercise compared to the Control Group with Training and the Control Group. Results of this study suggest that a novel procedure that focuses on removing obstacles to intended planned fitness activities is effective in increasing self-efficacy to engage in exercise among sedentary adults. Implications of these findings for use in applied settings and treatment studies are discussed.

  13. Microbiological analysis after complete or partial removal of carious dentin using two different techniques in primary teeth: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Deepak Kumar Singhal

    2016-01-01

    Conclusion: Results suggest the use of partial caries removal in a single session as compared to complete caries removal as a part of treatment of deep lesions in deciduous teeth in order to reduce the risk of pulp exposure. Partial caries removal using ART can be preferred for community settings as public health procedure for caries management.

  14. A combined hands-on teaching programme and clinical pathway focused on pleural ultrasound and procedure supervision transforms pleural procedure outcomes.

    Science.gov (United States)

    Edwards, Timothy; Cook, Alistair; Salamonsen, Matthew; Bashirzadeh, Farzad; Fielding, David

    2017-11-01

    Management of pleural effusions is a common diagnostic and management problem. We reviewed the outcomes from pleural procedures after the instigation of pleural effusion management guidelines, focusing on pleural ultrasound and a hands-on teaching programme followed by procedure supervision that enabled many operators to perform such procedures. This is a retrospective analysis of all procedures performed for pleural effusions on medical patients. Outcomes were assessed prior to the instigation of pleural effusion management guidelines (pleural pathway) and hands-on teaching (January 2010 to June 2011) and following these interventions (January 2012 to June 2013). A total of 171 procedures involving 129 patients (pre-pathway group) and 146 procedures involving 115 patients (post-pathway group) was analysed. The rate of complications prior to the pleural pathway was 22.2% (38 of 171 procedures). Following the pathway, the rate of complications declined to 7.5% (11 of 146 procedures, P < 0.003). The use of pleural ultrasound increased dramatically (72.5 vs 90.2%). The number of patients who underwent repeated procedures (defined as ≥3) reduced dramatically (21 vs 7, P < 0.01). This improvement occurred using many supervised operators who completed the hands-on teaching programme (n = 32) and followed the pleural pathway (127 of 146 procedures). The instigation of a clinical pathway focused on the use of bedside pleural ultrasound, and teaching of drainage techniques with procedure supervision vastly improved patient outcomes. This not only allowed better quality of care for patients, it also provided the acquisition of new skills to medical staff, not limiting these skills to specialised staff. © 2017 Royal Australasian College of Physicians.

  15. Is mammary reconstruction with the anatomical Becker expander a simple procedure? Complications and hidden problems leading to secondary surgical procedures: a follow-up study.

    Science.gov (United States)

    Farace, Francesco; Faenza, Mario; Bulla, Antonio; Rubino, Corrado; Campus, Gian Vittorio

    2013-06-01

    Debate over the role of Becker expander implants (BEIs) in breast reconstruction is still ongoing. There are no clear indications for BEI use. The main indications for BEI use are one-stage breast reconstruction procedure and congenital breast deformities correction, due to the postoperative ability to vary BEI volume. Recent studies showed that BEIs were removed 5 years after mammary reconstruction in 68% of operated patients. This entails a further surgical procedure. BEIs should not, therefore, be regarded as one-stage prostheses. We performed a case-series study of breast reconstructions with anatomically shaped Becker-35™ implants, in order to highlight complications and to flag unseen problems, which might entail a second surgical procedure. A total of 229 patients, reconstructed from 2005 to 2010, were enrolled in this study. Data relating to implant type, volume, mean operative time and complications were recorded. All the patients underwent the same surgical procedure. The minimum follow-up period was 18 months. During a 5-year follow-up, 99 patients required secondary surgery to correct their complications or sequelae; 46 of them underwent BEI removal within 2 years of implantation, 56 within 3 years, 65 within 4 years and 74 within 5 years. Our findings show that two different sorts of complications can arise with these devices, leading to premature implant removal, one common to any breast implant and one peculiar to BEIs. The Becker implant is a permanent expander. Surgeons must, therefore, be aware that, once positioned, the Becker expander cannot be adjusted at a later date, as in two-stage expander/prosthesis reconstructions for instance. Surgeons must have a clear understanding of possible BEI complications in order to be able to discuss these with their patients. Therefore, only surgeons experienced in breast reconstruction should use BEIs. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by

  16. Removal in a lump of JRR-3 nuclear reactor

    International Nuclear Information System (INIS)

    Ohnishi, Nobuaki; Suzuki, Masanori; Nagase, Tetsuo; Watanabe, Morinari.

    1989-01-01

    The research reactor JRR-3 in Japan Atomic Energy Research Institute is called 'Home made No.1 reactor' as all except fuel and heavy water as the moderator and coolant were manufactured in Japan. The JRR-3 attained the criticality in 1962, and the cumulative time of operation reached 47135.5 hours, and the cumulative power output reached 419073.5 MWh. It was stopped in 1983. During the period, it was utilized for beam experiment, irradiation of fuel and materials, RI production and others. In order to cope with the expansion of utilization and the advance of utilizing technology of the research reactor, the reconstruction works are in progress, and the criticality of the reconstructed reactor is expected in 1990. On the site where the old reactor is removed, the reactor of different type is installed, and the first large cold neutron source is equipped. In this report, as to the removal of the old reactor proper, the method of working and the results are described. Considering the period of working, the cost and the management of the removed reactor, in the case of the JRR-3, the method of carrying it out in a lump was adopted as the optimum removal method. The plan, procedure and results of the removal working are reported. (K.I.)

  17. Application of X-ray scanning and tomography to evaluate the filtercake removal efficiency

    International Nuclear Information System (INIS)

    Lopes, R.T.; Oliveira, L.F. de; Miranda, C.R.; Leite, J.C.

    2004-01-01

    The removal of the filtercake formed during the drilling operation is essential for a successful cementing job. Nowadays, the use of synthetic base fluids brings the necessity of proceeding new evaluations of the efficiency of the washes in removing the filtercake and to guarantee the wettability inversion of the formation from oil to waterwet. It is presented here the application of X-ray tomographic scanning to evaluate the filtercake removal efficiency performed by different washes. This technique uses a natural core with a perforation, where a filtercake is formed by circulating a drilling fluid. The wash is circulated through this perforation and the filtercake removal efficiency is measured precisely by computer tomography scanning. This procedure enables the filtercake removal visualization during the wash circulation through the formation and from the data obtained from the X-ray tomography it is possible to select the most appropriate wash for a given drilling fluid, as well as to predict the necessary contact time between the wash and the formation to achieve an appropriate filtercake removal

  18. Removal of I, Rn, Xe and Kr from off gas streams using PTFE membranes

    Science.gov (United States)

    Siemer, Darryl D.; Lewis, Leroy C.

    1990-01-01

    A process for removing I, R, Xe and Kr which involves the passage of the off gas stream through a tube-in-shell assembly, whereby the tubing is a PTFE membrane which permits the selective passages of the gases for removing and isolating the gases.

  19. Radon-removal techniques for small community public water supplies

    International Nuclear Information System (INIS)

    Kinner, N.E.; Malley, J.P.; Clement, J.A.; Quern, P.A.; Schell, G.S.

    1990-08-01

    The report presents the results of an evaluation, performed by the University of New Hampshire--Environmental Research Group (ERG), of radon removal in small community water supplies using full-scale granular activated carbon adsorption, diffused bubble aeration and packed tower aeration. Various low technology alternatives, such as loss in a distribution system and addition of coarse bubble aeration to a pilot-scale atmospheric storage tank were also evaluated. The report discusses each of the treatment alternatives with respect to their radon removal efficiency, potential problems (i.e., waste disposal, radiation exposure and intermedia pollution), and economics in small community applications. In addition, several sampling methods, storage times, scintillation cocktails and extraction procedures currently used in the liquid scintillation technique for analysis of radon in water were compared

  20. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  1. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  2. Early versus delayed dressing removal after primary closure of clean and clean-contaminated surgical wounds.

    Science.gov (United States)

    Toon, Clare D; Lusuku, Charnelle; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2015-09-03

    Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In March 2015 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared

  3. "Nara" knot for suturing of cleft lip in children to make removal easy

    Directory of Open Access Journals (Sweden)

    Obaidullah

    2006-01-01

    Full Text Available Cleft patients usually go through a lifetime of repeated hospital admissions and multiple procedures. Suture removal at a tender age and on a sensitive area like the lip becomes a challenge for the nursing staff. It is also emotionally demanding on the part of the parents. Hence, in most centres these patients are at least sedated if not anaesthetised. We have been using a simple knot and running prolene material so that undoing of the knot becomes easy and suture removal more or less atraumatic. We would like to share our experience with readers through this article. An analysis of 53 cleft lip repairs has shown that this knot is safe and easily removable.

  4. Hg⁰ removal from flue gas by ionic liquid/H₂O₂.

    Science.gov (United States)

    Cheng, Guangwen; Bai, Bofeng; Zhang, Qiang; Cai, Ming

    2014-09-15

    1-Alkyl-3-methylimidazolium chloride ionic liquids ([Cnmim] Cl, n=4, 6, 8) were prepared. The ionic liquid was then mixed with hydrogen peroxide (H2O2) to form an absorbent. The Hg(0) removal performance of the absorbent was investigated in a gas/liquid scrubber using simulated flue gas. It was found that the ionic liquid/H2O2 mixture was an excellent absorbent and could be used to remove Hg(0) from flue gas. When the mass ratio of H2O2 to ionic liquid was 0.5, the absorbent showed high Hg(0) removal efficiency (up to 98%). The Hg(0) removal efficiency usually increased with the absorption temperature, while decreased with the increase of alkyl chain length in ionic liquid molecule. The Hg(0) removal mechanism involved with Hg(0) oxidation by H2O2 and Hg(2+) transfer from aqueous phase to ionic liquid phase. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. A novel two-step mechanism for removal of a mitochondrial signal sequence involves the mAAA complex and the putative rhomboid protease Pcp1.

    Science.gov (United States)

    Esser, Karlheinz; Tursun, Baris; Ingenhoven, Martin; Michaelis, Georg; Pratje, Elke

    2002-11-08

    The yeast protein cytochrome c peroxidase (Ccp1) is nuclearly encoded and imported into the mitochondrial intermembrane space, where it is involved in degradation of reactive oxygen species. It is known, that Ccp1 is synthesised as a precursor with a N-terminal pre-sequence, that is proteolytically removed during transport of the protein. Here we present evidence for a new processing pathway, involving novel signal peptidase activities. The mAAA protease subunits Yta10 (Afg3) and Yta12 (Rca1) were identified both to be essential for the first processing step. In addition, the Pcp1 (Ygr101w) gene product was found to be required for the second processing step, yielding the mature Ccp1 protein. The newly identified Pcp1 protein belongs to the rhomboid-GlpG superfamily of putative intramembrane peptidases. Inactivation of the protease motifs in mAAA and Pcp1 blocks the respective steps of proteolysis. A model of coupled Ccp1 transport and N-terminal processing by the mAAA complex and Pcp1 is discussed. Similar processing mechanisms may exist, because the mAAA subunits and the newly identified Pcp1 protein belong to ubiquitous protein families.

  6. Ophthalmic surgical procedures in children at the University of Benin ...

    African Journals Online (AJOL)

    The second commonest indication for surgery was cataract (23.0%), while eyeball removal (9% of cases) due to tumours or infection was the third commonest surgical procedure. Strabismus and pterygium surgery were infrequently performed (0.9%). Late presentation for eye surgery was the pattern in most of the cases.

  7. Electrical power line and pole removal radiological survey completion report: Revision 2

    International Nuclear Information System (INIS)

    1989-02-01

    Each electric power pole and all wire, cross members, and attached hardware were radiologically surveyed and removed. The survey procedures did not conform in every respect with the planned procedures because the actual work differed from the removal plan. The survey showed that all contamination was fixed. Certain poles that were suspected of being contaminated with Th-230 were cut off one foot above ground level and left on site. Each truck load of materials was checked at the access point to ensure it met release criteria. Wood samples were taken from all the poles at Building 403 and 5% of all the rest and analyzed for U-238 and Th-232. Only U-238 was detected. 1903 bundles of wire (95,150 lin ft) were released, and 76 bundles (1520 lin ft) were found to be contaminated. 7163 lin ft of power pole material were released, and 1484 lin ft were contaminated. A comprehensive quality measure assurance/quality control program was applied to this work

  8. Success rates for initial eradication of peri-prosthetic knee infection treated with a two-stage procedure.

    Science.gov (United States)

    Kaminski, Andrzej; Citak, Mustafa; Schildhauer, Thomas Armin; Fehmer, Tobias

    2014-01-01

    In Germany, rates of primary total knee arthroplasty procedures and exchange arthroplasty procedures continue to rise. Late-onset peri-prosthetic infection constitutes a serious complication whose management may be dependent upon the spectrum of micro-organisms involved. The aim of this study was to provide a retrospective analysis of the effectiveness of initial eradication measures performed as part of a two-stage procedure. Between 2002 and 2008, a total of 328 patients who had received a first-time diagnosis of chronic peri-prosthetic knee infection following total knee arthroplasty (TKA) subsequently underwent surgery at our clinic. The surgical approach consisted of a two-stage procedure, with the initial procedure consisting of the removal of the prosthesis and radical debridement, followed by insertion of an antibiotic-loaded static spacer. The effectiveness of the procedure was assessed after six weeks, with each patient undergoing a number of clinical and laboratory-based tests, including knee joint aspiration. Staphylococcus aureus strains were responsible for 68% (n=223) of the total number of cases of peri-prosthetic knee infection. 19% of cases (n=62) showed evidence of gram-negative bacteria, while MRSA accounted for 15% (n=49) of cases. Six weeks after completion of the above-named treatment regimen, eradication of infection was considered successful in 289 patients (88.1%). Eradication was unsuccessful in 22% of MRSA infections (n=11) and 7% of MSSA infections (n=23). The treatment regimen outlined in this report is capable of achieving satisfactory results in the management of late-onset peri-prosthetic knee infection, with one exception: patients with infections caused by MRSA showed high failure rates.

  9. Radioisotopic studies concerning the efficacy of standard washing procedures for the cleansing of hair before zinc analysis

    International Nuclear Information System (INIS)

    Buckley, R.A.; Dreosti, I.E.

    1984-01-01

    Various standard procedures were investigated in relation to the removal of exogenously applied 65Zn from human hair and endogenously incorporated 65Zn from rat hair. Human hair was found to adsorb zinc and a variety of other metal ions from aqueous solutions in a manner which suggested some ion-exchange capacity. Uptake of zinc varied considerably between human hair samples, but in most cases accumulation of zinc occurred rapidly and often resulted in hair zinc levels several-fold higher than found in control samples. Extraction of zinc and other metal ions was greatest after treatment with disodium EDTA and sodium lauryl sulfate than after washing with water or aqueous Triton X-100. However, no procedure effectively removed all exogenous zinc, while all treatments extracted varying proportions of the endogenous zinc component. Because of the inability of standard washing procedures to remove exogenous zinc without reducing endogenous or indicator zinc levels, use of hair zinc analyses to indicate nutritional zinc status are inadvisable if hair zinc contamination is likely to have occurred

  10. [Evaluation of the cosmetic effect of orbital endoimplantation after removal the eyeball].

    Science.gov (United States)

    Piskiniene, Raimonda

    2006-01-01

    The purpose of our study was to evaluate the cosmetic effect of endoimplantation after removal the eyeball. The removal of the globe creates anatomic and physiological alteration of the orbital tissue and orbital bones. A volume deficit occurs when an eye is enucleated. Deep upper lid sulcus, ptosis, lower lid laxity, and enophthalmus of the artificial eye together constitute the postenucleation socket syndrome, which creates an asymmetry of the face. The orbital prosthesis by placing it in the orbital cavity allows correcting volume deficit, so the implant with attached extraocular muscles, together with an artificial eye, creates an illusion of real eye. Forty patients were operated on in Clinic of Eye Diseases of Kaunas University of Medicine Hospital. Twenty patients underwent removal of the eye and procedure of orbital implant insertion (main group). Twenty patients had just an eyeball removal without insertion of an orbital implant (control group). There was a statistically significant difference in exophthalmometry data between main and control groups (14.20+/-2.73 vs. 10.35+/-1.23 mm, respectively; peyeball removal.

  11. Endoscopic Removal of a Bullet That Migrated to the Third Ventricle Causing Hydrocephalus.

    Science.gov (United States)

    Aydoseli, Aydın; Unal, Tugrul Cem; Aras, Yavuz; Sabanci, Pulat Akın; Altunrende, Emre; Izgi, Nail

    2017-09-01

    Hydrocephalus caused by an intraventricular bullet is a rare event. We report a case of endoscopic removal of an intraventricular bullet. A 66-year-old man was admitted with a gunshot wound to the head after a suicide attempt. The bullet migrated from the frontal parenchyma to the third ventricle day 4 of admission. On day 21 of admission, the patient developed hydrocephalus with obstruction of the cerebral aqueduct. The bullet was accessed through an endoscopic third ventriculostomy and removed using an endoscope. Hydrocephalus may develop in patients with intraventricular foreign objects. When such objects must be removed, the endoscopic approach is a safe, efficient, and minimally invasive procedure. To our knowledge, this is the first case in the literature of foreign object removal from the ventricle via a transcortical endoscopic approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Mercury and tritium removal from DOE waste oils

    Energy Technology Data Exchange (ETDEWEB)

    Klasson, E.T. [Oak Ridge National Lab., TN (United States)

    1997-10-01

    This work covers the investigation of vacuum extraction as a means to remove tritiated contamination as well as the removal via sorption of dissolved mercury from contaminated oils. The radiation damage in oils from tritium causes production of hydrogen, methane, and low-molecular-weight hydrocarbons. When tritium gas is present in the oil, the tritium atom is incorporated into the formed hydrocarbons. The transformer industry measures gas content/composition of transformer oils as a diagnostic tool for the transformers` condition. The analytical approach (ASTM D3612-90) used for these measurements is vacuum extraction of all gases (H{sub 2}, N{sub 2}, O{sub 2}, CO, CO{sub 2}, etc.) followed by analysis of the evolved gas mixture. This extraction method will be adapted to remove dissolved gases (including tritium) from the SRS vacuum pump oil. It may be necessary to heat (60{degrees}C to 70{degrees}C) the oil during vacuum extraction to remove tritiated water. A method described in the procedures is a stripper column extraction, in which a carrier gas (argon) is used to remove dissolved gases from oil that is dispersed on high surface area beads. This method appears promising for scale-up as a treatment process, and a modified process is also being used as a dewatering technique by SD Myers, Inc. (a transformer consulting company) for transformers in the field by a mobile unit. Although some mercury may be removed during the vacuum extraction, the most common technique for removing mercury from oil is by using sulfur-impregnated activated carbon (SIAC). SIAC is currently being used by the petroleum industry to remove mercury from hydrocarbon mixtures, but the sorbent has not been previously tested on DOE vacuum oil waste. It is anticipated that a final process will be similar to technologies used by the petroleum industry and is comparable to ion exchange operations in large column-type reactors.

  13. Biofilms and Oxidizing Biocides; Evaluation of Disinfection and Removal Effects by Using Established Microbial Systems.

    Science.gov (United States)

    Tachikawa, Mariko

    2017-01-01

    The formation of bacterial biofilms and their disinfection and removal have been important subjects in the maintenance of water quality in areas such as public spas, swimming pools, food processing lines, industrial water systems, and in the hygienic control of medical devices, hospital procedures, etc. Presented here is an outline of biofilm formation, as well as studies on the disinfection and removal of biofilms by oxidizing biocides using established biofilms. These studies using established biofilms may increase the understanding of the variable response of biofilms to planktonic bacteria, and the unique aspects of oxidizing biocides in the disinfection and removal of biofilms.

  14. PROCEDURAL CONVENTION AND FLEXIBILITY OF THE PROCED URE: THE INFLUENCE OF PRIVATE AUTONOMY ON THE PUBLICIST PARADIGM OF CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Marcelo Dias Ponte

    2015-12-01

    Full Text Available The research aims to analyze the New CPC innovations with regard to the procedural legal business, to assess, carefully, it s possibilities, its limits, requirements and the function of the court and the parties to the flexibility of the procedure. The study approaches the shared management of the procedure, the procedural calendar as materializing institute the principle of efficiency. As a result, it was found that procedural conventions have the power to better protect the substantive rights involved in the dispute, since the litigants may bring the procedural rite to the needs of the conflict, allowing a view democratic demand, able to increase dialogue and interaction between the parties.

  15. Successful Insular Glioma Removal in a Deaf Signer Patient During an Awake Craniotomy Procedure.

    Science.gov (United States)

    Metellus, Philippe; Boussen, Salah; Guye, Maxime; Trebuchon, Agnes

    2017-02-01

    Resection of tumors located within the insula of the dominant hemisphere represents a technical challenge because of the complex anatomy, including the surrounding vasculature, and the relationship to functional (motor and language) structures. We report here the case of a successful resection of a left insular glioma in a native deaf signer during an awake craniotomy. The patient, a congenitally deaf right-handed patient who is a native user of sign language, presented with a seizure 1 week before he was referred to our department. Magnetic resonance imaging revealed a left heterogeneous insular tumor enhanced after intravenous gadolinium infusion. Because of its deep and dominant hemisphere location, an awake craniotomy was decided. The patient was evaluated intraoperatively using object naming, text reading, and sign repetition tasks. An isolated inferior frontal gyrus site evoked repeated object naming errors. A transopercular parietal approach was performed and allowed the successful removal of the tumor under direct electric stimulation and electrocorticography. To our knowledge, this is the first report of successful removal of a left insular tumor without any functional sequelae in a native deaf signer using intraoperative direct cerebral stimulation during an awake craniotomy. The methodology used also provides the first evidence of the actual anatomo-functional organization of language in deaf signers. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Increased risk for complications following removal of hardware in patients with liver disease, pilon or pelvic fractures: A regression analysis.

    Science.gov (United States)

    Brown, Bryan D; Steinert, Justin N; Stelzer, John W; Yoon, Richard S; Langford, Joshua R; Koval, Kenneth J

    2017-12-01

    Indications for removing orthopedic hardware on an elective basis varies widely. Although viewed as a relatively benign procedure, there is a lack of data regarding overall complication rates after fracture fixation. The purpose of this study is to determine the overall short-term complication rate for elective removal of orthopedic hardware after fracture fixation and to identify associated risk factors. Adult patients indicated for elective hardware removal after fracture fixation between July 2012 and July 2016 were screened for inclusion. Inclusion criteria included patients with hardware related pain and/or impaired cosmesis with complete medical and radiographic records and at least 3-month follow-up. Exclusion criteria were those patients indicated for hardware removal for a diagnosis of malunion, non-union, and/or infection. Data collected included patient age, gender, anatomic location of hardware removed, body mass index, ASA score, and comorbidities. Overall complications, as well as complications requiring revision surgery were recorded. Statistical analysis was performed with SPSS 20.0, and included univariate and multivariate regression analysis. 391 patients (418 procedures) were included for analysis. Overall complication rates were 8.4%, with a 3.6% revision surgery rate. Univariate regression analysis revealed that patients who had liver disease were at significant risk for complication (p=0.001) and revision surgery (p=0.036). Multivariate regression analysis showed that: 1) patients who had liver disease were at significant risk of overall complication (p=0.001) and revision surgery (p=0.039); 2) Removal of hardware following fixation for a pilon had significantly increased risk for complication (p=0.012), but not revision surgery (p=0.43); and 3) Removal of hardware for pelvic fixation had a significantly increased risk for revision surgery (p=0.017). Removal of hardware following fracture fixation is not a risk-free procedure. Patients with

  17. Ethics of fertility preservation for prepubertal children: should clinicians offer procedures where efficacy is largely unproven?

    Science.gov (United States)

    McDougall, Rosalind J; Gillam, Lynn; Delany, Clare; Jayasinghe, Yasmin

    2018-01-01

    Young children with cancer are treated with interventions that can have a high risk of compromising their reproductive potential. ‘Fertility preservation’ for children who have not yet reached puberty involves surgically removing and cryopreserving reproductive tissue prior to treatment in the expectation that strategies for the use of this tissue will be developed in the future. Fertility preservation for prepubertal children is ethically complex because the techniques largely lack proven efficacy for this age group. There is professional difference of opinion about whether it is ethical to offer such ‘experimental’ procedures. The question addressed in this paper is: when, if ever, is it ethically justifiable to offer fertility preservation surgery to prepubertal children? We present the ethical concerns about prepubertal fertility preservation, drawing both on existing literature and our experience discussing this issue with clinicians in clinical ethics case consultations. We argue that offering the procedure is ethically justifiable in certain circumstances. For many children, the balance of benefits and burdens is such that the procedure is ethically permissible but not ethically required; when the procedure is medically safe, it is the parents’ decision to make, with appropriate information and guidance from the treating clinicians. We suggest that clinical ethics support processes are necessary to assist clinicians to engage with the ethical complexity of prepubertal fertility preservation and describe the framework that has been integrated into the pathway of care for patients and families attending the Royal Children’s Hospital in Melbourne, Australia. PMID:29084865

  18. The "Hands Together" Method of Nonsterile Scalpel Blade Mounting and Removal

    Science.gov (United States)

    Cornwall, Jon

    2014-01-01

    Scalpels are utilized by many different user groups for such purposes as medical procedures and dissection. Injuries caused by scalpels are a potential risk for scalpel users, and include injuries that may occur while mounting and removing the scalpel blade. Between 10% and 20% of all scalpel injuries in education and healthcare settings are…

  19. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  20. Arsenic and iron removal from groundwater by oxidation-coagulation at optimized pH: laboratory and field studies.

    Science.gov (United States)

    Bordoloi, Shreemoyee; Nath, Suresh K; Gogoi, Sweety; Dutta, Robin K

    2013-09-15

    A three-step treatment process involving (i) mild alkaline pH-conditioning by NaHCO₃; (ii) oxidation of arsenite and ferrous ions by KMnO₄, itself precipitating as insoluble MnO₂ under the pH condition; and (iii) coagulation by FeCl₃ has been used for simultaneous removal of arsenic and iron ions from water. The treated water is filtered after a residence time of 1-2 h. Laboratory batch experiments were performed to optimize the doses. A field trial was performed with an optimized recipe at 30 households and 5 schools at some highly arsenic affected villages in Assam, India. Simultaneous removals of arsenic from initial 0.1-0.5 mg/L to about 5 μg/L and iron from initial 0.3-5.0 mg/L to less than 0.1 mg/L have been achieved along with final pH between 7.0 and 7.5 after residence time of 1h. The process also removes other heavy elements, if present, without leaving any additional toxic residue. The small quantity of solid sludge containing mainly ferrihydrite with adsorbed arsenate passes the toxicity characteristic leaching procedure (TCLP) test. The estimated recurring cost is approximately USD 0.16 per/m(3) of purified water. A high efficiency, an extremely low cost, safety, non-requirement of power and simplicity of operation make the technique potential for rural application. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Removal of benzaldehyde from a water/ethanol mixture by applying scavenging techniques

    DEFF Research Database (Denmark)

    Mitic, Aleksandar; Skov, Thomas; Gernaey, Krist V.

    2017-01-01

    A presence of carbonyl compounds is very common in the food industry. The nature of such compounds is to be reactive and thus many products involve aldehydes/ketones in their synthetic routes. By contrast, the high reactivity of carbonyl compounds could also lead to formation of undesired compounds......, such as genotoxic impurities. It can therefore be important to remove carbonyl compounds by implementing suitable removal techniques, with the aim of protecting final product quality. This work is focused on benzaldehyde as a model component, studying its removal from a water/ethanol mixture by applying different...

  2. Mechanism of uranium (VI) removal by two anaerobic bacterial communities

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Monica [Centro de Ciencias do Mar, Universidade do Algarve, FCT-DQF (edificio 8), Campus de Gambelas, 8005-139 Faro (Portugal); Faleiro, Maria Leonor [IBB - Centro de Biomedicina Molecular e Estrutural, Universidade do Algarve, FCT, Campus de Gambelas, 8005-139 Faro (Portugal); Costa, Ana M. Rosa da [Centro de Investigacao em Quimica do Algarve, Universidade do Algarve, FCT, DQF, Campus de Gambelas, 8005-139 Faro (Portugal); Chaves, Sandra; Tenreiro, Rogerio [Universidade de Lisboa, Faculdade de Ciencias, Centro de Biodiversidade, Genomica Integrativa e Funcional (BioFIG), Campus de FCUL, Campo Grande, 1749-016 Lisboa (Portugal); Matos, Antonio Pedro [Servico de Anatomia Patologica, Hospital Curry Cabral, Lisboa (Portugal); Costa, Maria Clara, E-mail: mcorada@ualg.pt [Centro de Ciencias do Mar, Universidade do Algarve, FCT-DQF (edificio 8), Campus de Gambelas, 8005-139 Faro (Portugal)

    2010-12-15

    The mechanism of uranium (VI) removal by two anaerobic bacterial consortia, recovered from an uncontaminated site (consortium A) and other from an uranium mine (consortium U), was investigated. The highest efficiency of U (VI) removal by both consortia (97%) occurred at room temperature and at pH 7.2. Furthermore, it was found that U (VI) removal by consortium A occurred by enzymatic reduction and bioaccumulation, while the enzymatic process was the only mechanism involved in metal removal by consortium U. FTIR analysis suggested that after U (VI) reduction, U (IV) could be bound to carboxyl, phosphate and amide groups of bacterial cells. Phylogenetic analysis of 16S rRNA showed that community A was mainly composed by bacteria closely related to Sporotalea genus and Rhodocyclaceae family, while community U was mainly composed by bacteria related to Clostridium genus and Rhodocyclaceae family.

  3. Mechanism of uranium (VI) removal by two anaerobic bacterial communities

    International Nuclear Information System (INIS)

    Martins, Monica; Faleiro, Maria Leonor; Costa, Ana M. Rosa da; Chaves, Sandra; Tenreiro, Rogerio; Matos, Antonio Pedro; Costa, Maria Clara

    2010-01-01

    The mechanism of uranium (VI) removal by two anaerobic bacterial consortia, recovered from an uncontaminated site (consortium A) and other from an uranium mine (consortium U), was investigated. The highest efficiency of U (VI) removal by both consortia (97%) occurred at room temperature and at pH 7.2. Furthermore, it was found that U (VI) removal by consortium A occurred by enzymatic reduction and bioaccumulation, while the enzymatic process was the only mechanism involved in metal removal by consortium U. FTIR analysis suggested that after U (VI) reduction, U (IV) could be bound to carboxyl, phosphate and amide groups of bacterial cells. Phylogenetic analysis of 16S rRNA showed that community A was mainly composed by bacteria closely related to Sporotalea genus and Rhodocyclaceae family, while community U was mainly composed by bacteria related to Clostridium genus and Rhodocyclaceae family.

  4. 14 CFR 25.1585 - Operating procedures.

    Science.gov (United States)

    2010-01-01

    ...) Non-normal procedures for malfunction cases and failure conditions involving the use of special... envelopes, determined under § 25.251 must be furnished. The buffet onset envelopes presented may reflect the...

  5. Guidelines for procedural pain in the newborn

    Science.gov (United States)

    Lago, Paola; Garetti, Elisabetta; Merazzi, Daniele; Pieragostini, Luisa; Ancora, Gina; Pirelli, Anna; Bellieni, Carlo Valerio

    2009-01-01

    Despite accumulating evidence that procedural pain experienced by newborn infants may have acute and even long-term detrimental effects on their subsequent behaviour and neurological outcome, pain control and prevention remain controversial issues. Our aim was to develop guidelines based on evidence and clinical practice for preventing and controlling neonatal procedural pain in the light of the evidence-based recommendations contained in the SIGN classification. A panel of expert neonatologists used systematic review, data synthesis and open discussion to reach a consensus on the level of evidence supported by the literature or customs in clinical practice and to describe a global analgesic management, considering pharmacological, non-pharmacological, behavioural and environmental measures for each invasive procedure. There is strong evidence to support some analgesic measures, e.g. sucrose or breast milk for minor invasive procedures, and combinations of drugs for tracheal intubation. Many other pain control measures used during chest tube placement and removal, screening and treatment for ROP, or for postoperative pain, are still based not on evidence, but on good practice or expert opinions. Conclusion: These guidelines should help improving the health care professional's awareness of the need to adequately manage procedural pain in neonates, based on the strongest evidence currently available. PMID:19484828

  6. Iterative Outlier Removal: A Method for Identifying Outliers in Laboratory Recalibration Studies.

    Science.gov (United States)

    Parrinello, Christina M; Grams, Morgan E; Sang, Yingying; Couper, David; Wruck, Lisa M; Li, Danni; Eckfeldt, John H; Selvin, Elizabeth; Coresh, Josef

    2016-07-01

    Extreme values that arise for any reason, including those through nonlaboratory measurement procedure-related processes (inadequate mixing, evaporation, mislabeling), lead to outliers and inflate errors in recalibration studies. We present an approach termed iterative outlier removal (IOR) for identifying such outliers. We previously identified substantial laboratory drift in uric acid measurements in the Atherosclerosis Risk in Communities (ARIC) Study over time. Serum uric acid was originally measured in 1990-1992 on a Coulter DACOS instrument using an uricase-based measurement procedure. To recalibrate previous measured concentrations to a newer enzymatic colorimetric measurement procedure, uric acid was remeasured in 200 participants from stored plasma in 2011-2013 on a Beckman Olympus 480 autoanalyzer. To conduct IOR, we excluded data points >3 SDs from the mean difference. We continued this process using the resulting data until no outliers remained. IOR detected more outliers and yielded greater precision in simulation. The original mean difference (SD) in uric acid was 1.25 (0.62) mg/dL. After 4 iterations, 9 outliers were excluded, and the mean difference (SD) was 1.23 (0.45) mg/dL. Conducting only one round of outlier removal (standard approach) would have excluded 4 outliers [mean difference (SD) = 1.22 (0.51) mg/dL]. Applying the recalibration (derived from Deming regression) from each approach to the original measurements, the prevalence of hyperuricemia (>7 mg/dL) was 28.5% before IOR and 8.5% after IOR. IOR is a useful method for removal of extreme outliers irrelevant to recalibrating laboratory measurements, and identifies more extraneous outliers than the standard approach. © 2016 American Association for Clinical Chemistry.

  7. Postoperative infections in craniofacial reconstructive procedures.

    Science.gov (United States)

    Fialkov, J A; Holy, C; Forrest, C R; Phillips, J H; Antonyshyn, O M

    2001-07-01

    The rate of, and possible risk factors for, postoperative craniofacial infection is unclear. To investigate this problem, we reviewed 349 cases of craniofacial skeletal procedures performed from 1996 to 1999 at our institution. Infection rate was determined and correlated with the use of implants, operative site, and cause of deformity. The inclusion criteria consisted of all procedures requiring autologous or prosthetic implantation in craniofacial skeletal sites, as well as all procedures involving bone or cartilage resection, osteotomies, debridement, reduction and/or fixation. Procedures that did not involve bone or cartilage surgery were excluded. The criteria for diagnosis of infection included clinical confirmation and one or more of 1) intravenous or oral antibiotic treatment outside of the prophylactic surgical regimen; 2) surgical intervention for drainage, irrigation, and or debridement; and 3) microbiological confirmation. Among the 280 surgical cases that fit the inclusion criteria and had complete records, there were 23 cases of postoperative infection (8.2%). The most common site for postoperative infection was the mandible (infection rate = 16.7%). Multiple logistic regression analysis revealed gunshot wound to be the most significant predictor of postoperative infection. Additionally, porous polyethylene implantation through a transoral route was correlated with a significant risk of postoperative infection.

  8. A novel surface cleaning method for chemical removal of fouling lead layer from chromium surfaces

    International Nuclear Information System (INIS)

    Gholivand, Kh.; Khosravi, M.; Hosseini, S.G.; Fathollahi, M.

    2010-01-01

    Most products especially metallic surfaces require cleaning treatment to remove surface contaminations that remain after processing or usage. Lead fouling is a general problem which arises from lead fouling on the chromium surfaces of bores and other interior parts of systems which have interaction with metallic lead in high temperatures and pressures. In this study, a novel chemical solution was introduced as a cleaner reagent for removing metallic lead pollution, as a fouling metal, from chromium surfaces. The cleaner aqueous solution contains hydrogen peroxide (H 2 O 2 ) as oxidizing agent of lead layer on the chromium surface and acetic acid (CH 3 COOH) as chelating agent of lead ions. The effect of some experimental parameters such as acetic acid concentration, hydrogen peroxide concentration and temperature of the cleaner solution during the operation on the efficiency of lead cleaning procedure was investigated. The results of scanning electron microscopy (SEM) showed that using this procedure, the lead pollution layer could be completely removed from real chromium surfaces without corrosion of the original surface. Finally, the optimum conditions for the complete and fast removing of lead pollution layer from chromium surfaces were proposed. The experimental results showed that at the optimum condition (acetic acid concentration 28% (V/V), hydrogen peroxide 8% (V/V) and temperature 35 deg. C), only 15-min time is needed for complete removal of 3 g fouling lead from a chromium surface.

  9. Mesh removal following transvaginal mesh placement: a case series of 104 operations.

    Science.gov (United States)

    Marcus-Braun, Naama; von Theobald, Peter

    2010-04-01

    The objective of the study was to reveal the way we treat vaginal mesh complications in a trained referral center. This is a retrospective review of all patients who underwent surgical removal of transvaginal mesh for mesh-related complications during a 5-year period. Eighty-three patients underwent 104 operations including 61 complete mesh removal, 14 partial excision, 15 section of sub-urethral sling, and five laparoscopies. Main indications were erosion, infection, granuloma, incomplete voiding, and pain. Fifty-eight removals occurred more than 2 years after the primary mesh placement. Mean operation time was 21 min, and there were two intraoperative and ten minor postoperative complications. Stress urinary incontinence (SUI) recurred in 38% and cystocele in 19% of patients. In a trained center, mesh removal was found to be a quick and safe procedure. Mesh-related complications may frequently occur more than 2 years after the primary operation. Recurrence was mostly associated with SUI and less with genital prolapse.

  10. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Mustafa Seyhan; Olcay Guler; Mahir Mahirogullari; Ferdi Donmez; Arel Gereli; Serhat Mutlu

    2018-01-01

    Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of ...

  11. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-01-01

    Objectives Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of t...

  12. Comparing fixation used for calcaneal displacement osteotomies: a look at removal rates and cost.

    Science.gov (United States)

    Lucas, Douglas E; Simpson, G Alex; Philbin, Terrence M

    2015-02-01

    The calcaneal displacement osteotomy is a procedure frequently used by foot and ankle surgeons for hindfoot angular deformity. Traditional techniques use compression screw fixation that can result in prominent hardware. While the results of the procedure are generally good, a common concern is the development of plantar heel pain related to prominent hardware. The primary purpose of this study is to retrospectively compare clinical outcomes of 2 fixation methods for the osteotomy. Secondarily a cost analysis will compare implant costs to hardware removal costs. Records were reviewed for patients who had undergone a calcaneal displacement osteotomy fixated with either lag screw or a locked lateral compression plate (LLCP). Neuropathy, previous ipsilateral calcaneus surgery, heel pad trauma, or incomplete radiographic follow-up were exclusionary. Thirty-two patients (19.4%) required hardware removal from the screw fixation group compared to 1 (1.6%) of the LLCP group, which is significant (P cost was remarkably different with screw fixation costing on average $247.12, compared to the LLCP costing $1175.59. Although the LLCP cost was significantly higher, cost savings were identified when the cost of removal and removal rates were included. This study demonstrates that this device provides adequate stabilization for healing in equivalent time to screw fixation. The LLCP required decreased rates of hardware removal with fewer postoperative visits over a shorter period of time. Significant savings were demonstrated in the LLCP group despite the higher implant cost. Therapeutic, Level III, Retrospective Comparative Study. © 2014 The Author(s).

  13. Removal of detergents from SDS-inactivated dextransucrase

    International Nuclear Information System (INIS)

    Husman, D.W.; Mayer, R.M.

    1986-01-01

    Dextransucrase, which is rapidly inactivated by SDS, can be reactivated upon the addition of Triton X-100. Purification of the enzyme, in good yield and homogeneity, has been achieved by chromatography in the presence of SDS. The purified enzyme can be reactivated with Triton, but has large amounts of detergents. It was important to develop procedures for their removal. Density gradient centrifugation of SDS-inactivated or Triton-reactivated enzyme, treatment with Extracti-Gel D (Pierce) or chromatography on hydroxyl apatite (HA), have been examined for their effectiveness in providing detergent-free enzyme in good yield. Ultracentrifugation of SDS-inactivated protein provided limited recovery of active enzyme, but suggested that reactivation could be achieved by the simple removal of the detergent. While similar behavior was observed when the enzyme was eluted from Extracti-Gel, it was also shown that the limited recovery was a result of irreversible inactivation of the enzyme. Recovery could be improved if the enzyme was collected in solutions containing Triton, which has been reported to be a stabilizer. Chromatography of SDS-inactivated enzyme on HA also yielded active enzyme. Good recovery was obtained when Triton-reactivated enzyme was employed in these studies. The degree of detergent removal was determined by utilizing radiolabelled SDS and Triton X-100

  14. Clinical evaluation of failures in removable partial dentures.

    Science.gov (United States)

    Jorge, Janaina H; Quishida, Cristiane C C; Vergani, Carlos E; Machado, Ana L; Pavarina, Ana C; Giampaolo, Eunice T

    2012-01-01

    The aim of this clinical study was to evaluate the effects of removable partial dentures on the support tissues and changes occurring in lower tooth-supported and bilateral distal-extension dentures, 5 years after placement. The study involved analysis of a total of 53 patients who received prosthetic treatment for removable partial dentures. The patients were divided into two groups. In group 1, the patients had a completely edentulous maxilla and an edentulous area with natural teeth remaining in both the anterior and posterior regions. In group 2, the patients had a completely edentulous maxilla and partially edentulous mandible with preserved anterior teeth. Tooth mobility, prevalence of caries, fracture of the abutment teeth, fracture and/or deformation of the removable partial denture components and stability of the denture base were evaluated. The use of a removable partial denture increased tooth mobility, reduced the prevalence of caries, and did not cause loss or fracture of the abutments or damage to their components, when compared with the baseline. It was concluded that there was no difference between the groups as evaluated in terms of tooth mobility, prevalence of caries, loss and fracture of the abutments or damage to the components of the removable partial denture.

  15. SASS wind ambiguity removal by direct minimization. II - Use of smoothness and dynamical constraints

    Science.gov (United States)

    Hoffman, R. N.

    1984-01-01

    A variational analysis method (VAM) is used to remove the ambiguity of the Seasat-A Satellite Scatterometer (SASS) winds. The VAM yields the best fit to the data by minimizing an objective function S which is a measure of the lack of fit. The SASS data are described and the function S and the analysis procedure are defined. Analyses of a single ship report which are analogous to Green's functions are presented. The analysis procedure is tuned and its sensitivity is described using the QE II storm. The procedure is then applied to a case study of September 6, 1978, south of Japan.

  16. New procedure for the control of the treatment of industrial effluents to remove volatile organosulfur compounds.

    Science.gov (United States)

    Boczkaj, Grzegorz; Makoś, Patrycja; Fernandes, André; Przyjazny, Andrzej

    2016-10-01

    We present a new procedure for the determination of volatile organosulfur compounds in samples of industrial effluents using dispersive liquid-liquid microextraction and gas chromatography with flame photometric detection. Initially, the extraction parameters were optimized. These included: type and volume of extraction solvent, volume of disperser solvent, salting out effect, pH, time and speed of centrifugation as well as extraction time. The procedure was validated for 30 compounds. The developed procedure has low detection limits of 0.0071-0.49 μg/L and a good precision (relative standard deviation values of 1.2-5.0 and 0.6-4.1% at concentrations of 1 and 10 μg/L, respectively). The procedure was used to determine the content of volatile organosulfur compounds in samples of effluents from the production of bitumens before and after chemical treatment, in which six compounds were identified, including 2-mercaptoethanol, thiophenol, thioanisole, dipropyl disulfide, 1-decanethiol, and phenyl isothiocyanate at concentrations ranging from 0.47 to 8.89 μg/L. Problems in the determination of organosulfur compounds related to considerable changes in composition of the effluents, increase in concentration of individual compounds and appearance of secondary pollutants during effluent treatment processes are also discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Radiation exposure to staff involved in diagnostic and therapeutic nuclear medicine procedures in some hospitals in Sudan

    International Nuclear Information System (INIS)

    Salih, Lamia Hamza Bashir

    2015-05-01

    Study was performed to evaluate radiation dose to staff involved in nuclear medicine procedures in some hospitals in Sudan. 15 radiation workers were studied in three hospitals. Radiation dose was measured using personal dose equivalent Hp (10), using calibrated electronic personal dosimeters (EPDs) worn on the chest and read at the end of the day. Staff doses were monitored in each hospital for a period of four weeks, The measured monthly Hp(10) values to staff ranged between 82.96-83.94μSv (to nurses), 38.81-53.97 μSv (to pharmacists), 16.87-70.21μSv (to technologists), 40.22-76.56μSv (to medical physicists). These mean monthly radiation doses were projected to the annual radiation doses received by the staff. The mean monthly radiation doses were projected to the annual radiation doses were found to be between ranges (185.57-923.34μSv/y). Results found showed that there was no dose that exceeded the limits of annual dose recommended for workers by International Commission on Radiology Protection (ICRP) (20 mSv/year). This study is expected to increase the awareness of staff about the radiation hazards and protection.(Author)

  18. Memory Outcomes Following Selective versus Nonselective Temporal Lobe Removal: A Systematic Review

    Science.gov (United States)

    Girgis, Fady

    2012-01-01

    The surgical removal of brain tissue for the treatment of temporal lobe epilepsy can be either nonselective, as with an anterior temporal lobectomy (ATL), or selective, as with a selective amygdalohippocampectomy (SAH). Although seizure outcomes are similar with both procedures, cognitive and memory outcomes remain a matter of debate. This study…

  19. Licensing procedures for Low-Level Waste disposal facilities

    International Nuclear Information System (INIS)

    Roop, R.D.; Van Dyke, J.W.

    1985-09-01

    This report describes the procedures applicable to siting and licensing of disposal facilities for low-level radioactive wastes. Primary emphasis is placed on those procedures which are required by regulations, but to the extent possible, non-mandatory activities which will facilitate siting and licensing are also considered. The report provides an overview of how the procedural and technical requirements for a low-level waste (LLW) disposal facility (as defined by the Nuclear Regulatory Commission's Rules 10 CFR Parts 2, 51, and 61) may be integrated with activities to reduce and resolve conflict generated by the proposed siting of a facility. General procedures are described for site screening and selection, site characterization, site evaluation, and preparation of the license application; specific procedures for several individual states are discussed. The report also examines the steps involved in the formal licensing process, including docketing and initial processing, preparation of an environmental impact statement, technical review, hearings, and decisions. It is concluded that development of effective communication between parties in conflict and the utilization of techniques to manage and resolve conflicts represent perhaps the most significant challenge for the people involved in LLW disposal in the next decade. 18 refs., 6 figs

  20. Potential use of maize waste for the removal of Pb(II) from aqueous solution

    CSIR Research Space (South Africa)

    Okonkwo, J

    2006-09-01

    Full Text Available batch adsorption procedures. The utilization of tassels for the removal of toxic heavy metals from effluent solutions would, however, attach some economic value to this waste material. Tassel flowers were collected just prior to harvest, dried under...

  1. ARSENIC REMOVAL BY IRON REMOVAL PROCESSES

    Science.gov (United States)

    Presentation will discuss the removal of arsenic from drinking water using iron removal processes that include oxidation/filtration and the manganese greensand processes. Presentation includes results of U.S. EPA field studies conducted in Michigan and Ohio on existing iron remo...

  2. Mixture-based gatekeeping procedures in adaptive clinical trials.

    Science.gov (United States)

    Kordzakhia, George; Dmitrienko, Alex; Ishida, Eiji

    2018-01-01

    Clinical trials with data-driven decision rules often pursue multiple clinical objectives such as the evaluation of several endpoints or several doses of an experimental treatment. These complex analysis strategies give rise to "multivariate" multiplicity problems with several components or sources of multiplicity. A general framework for defining gatekeeping procedures in clinical trials with adaptive multistage designs is proposed in this paper. The mixture method is applied to build a gatekeeping procedure at each stage and inferences at each decision point (interim or final analysis) are performed using the combination function approach. An advantage of utilizing the mixture method is that it enables powerful gatekeeping procedures applicable to a broad class of settings with complex logical relationships among the hypotheses of interest. Further, the combination function approach supports flexible data-driven decisions such as a decision to increase the sample size or remove a treatment arm. The paper concludes with a clinical trial example that illustrates the methodology by applying it to develop an adaptive two-stage design with a mixture-based gatekeeping procedure.

  3. [Ureteral realignment with the rendezvous procedure in complex ureteral injuries - aspects of technique and our experience].

    Science.gov (United States)

    Brandt, Alexander Sascha; von Rundstedt, F-C; Lazica, D A; Roth, S

    2010-07-01

    The rendezvous procedure for re-establishing ureteral continuity after complex ureteral injuries is introduced and we present our experience with this technique. Aspects of the technique are described in a detailed step-by-step instruction using intraoperative radiographs. We evaluated our patient data from 1998 until 2009 for cases in which the rendezvous procedure was attempted. The rendezvous procedure was used in a total of 11 patients. Realignment was successful in 10 cases (90.9 %) and the initial nephrostomy could be removed. In 3 of 7 cases postoperative removal of the JJ ureteric stent was successful. In 7 patients the final surgical ureter reconstruction was performed after a medium period of 7 months. 5 cases of ureteroneocystostomy and 2 cases of reconstruction of the ureter either with colon or ileum segments were accomplished. In 1 patient a permanent maintenance of the DJ ureteral stent was necessary. Ureteral realignment with the rendezvous procedure enables disposition of the ureteral stent in many cases, exclusively antegrade or retrograde procedures failed. By this means nephrostomy could be spared as a temporary or permanent solution and a better chance of restitutio ad integrum could be realised. Georg Thieme Verlag KG Stuttgart * New York.

  4. Reaction mechanism of dicofol removal by cellulase.

    Science.gov (United States)

    Wang, Ziyuan; Yang, Ting; Zhai, Zihan; Zhang, Boya; Zhang, Jianbo

    2015-10-01

    It remains unclear whether dicofol should be defined as a persistent organic pollutant. Its environmental persistence has gained attention. This study focused on its degradation by cellulase. Cellulase was separated using a gel chromatogram, and its degradation activity towards dicofol involved its endoglucanase activity. By analyzing the kinetic parameters of cellulase reacting with mixed substrates, it was shown that cellulase reacted on dicofol and carboxyl methyl cellulose through two different active centers. Thus, the degradation of dicofol was shown to be an oxidative process by cellulase. Next, by comparing the impacts of tert-butyl alcohol (a typical OH free-radical inhibitor) on the removal efficiencies of dicofol under both cellulase and Fenton reagent systems, it was shown that the removal of dicofol was initiated by OH free radicals produced by cellulase. Finally, 4,4'-dichloro-dibenzophenone and chloride were detected using gas chromatography mass spectrometry and ion chromatography analysis, which supported our hypothesis. The reaction mechanism was analyzed and involved an attack by OH free radicals at the orthocarbon of dicofol, resulting in the degradation product 4,4'-dichloro-dibenzophenone. Copyright © 2015. Published by Elsevier B.V.

  5. SAFL Baffle retrofit for suspended sediment removal in storm sewer sumps.

    Science.gov (United States)

    Howard, Adam; Mohseni, Omid; Gulliver, John; Stefan, Heinz

    2011-11-15

    Standard sumps (manholes) provide a location for pipe junctions and maintenance access in stormwater drainage systems. Standard sumps can also remove sand and silt particles from stormwater, but have a high propensity for washout of the collected sediment. With appropriate maintenance these sumps may qualify as a stormwater best management practice (BMP) device for the removal of suspended sediment from stormwater runoff. To decrease the maintenance frequency and prevent standard sumps from becoming a source of suspended sediment under high flow conditions, a porous baffle, named the SAFL Baffle, has been designed and tested as a retrofit to the sump. Multiple configurations with varying percent open area and different angles of attack were evaluated in scale models. An optimum configuration was then constructed at the prototype scale and evaluated for both removal efficiency and washout. Results obtained with the retrofit indicate that with the right baffle dimensions and porosity, sediment washout from the sump at high flow rates can be almost eliminated, and removal efficiency can be significantly increased at low flow rates. Removal efficiency and washout functions have been developed for standard sumps retrofitted with the SAFL Baffle. The results of this research provide a new, versatile stormwater treatment device and implemented new washout and removal efficiency testing procedures that will improve research and development of stormwater treatment devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Mechanisms of hexavalent chromium resistance and removal by microorganisms.

    Science.gov (United States)

    Joutey, Nezha Tahri; Sayel, Hanane; Bahafid, Wifak; El Ghachtouli, Naïma

    2015-01-01

    Chromium has been and is extensively used worldwide in multiple industrial processes and is routinely discharged to the environment from such processes. Therefore, this heavy metal is a potential threat to the environment and to public health, primarily because it is non-biodegradable and environmentally persistent. Chromium exists in several oxidation states, the most stable of which are trivalent Cr(Ill) and hexavalent Cr(VI) species. Each species possesses its own individual chemical characteristics and produces its own biological effects. For example, Cr (Ill) is an essential oligoelement for humans, whereas Cr(VI) is carcinogenic and mutagenic. Several chemical methods are used to remove Cr(VI) from contaminated sites. Each of these methods has advantages and disadvantages. Currently, bioremediation is often the preferred method to deal with Cr contaminated sites, because it is eco-friendly, cost-effective and is a "natural" technology. Many yeast, bacterial and fungal species have been assessed for their suitability to reduce or remove Cr(VI) contamination. The mechanisms by which these microorganisms resist and reduce Cr(VI) are variable and are species dependent. There are several Cr-resistance mechanisms that are displayed by microorganisms. These include active efflux of Cr compounds, metabolic reduction of Cr(VI) to Cr (ill), and either intercellular or extracellular prec1p1tation. Microbial Cr (VI) removal typically involves three stages: binding of chromium to the cell surface, translocation of chromium into the cell, and reduction of Cr(VI) to Cr (ill). Cr(VI) reduction by microorganisms may proceed on the cell surface, outside the cell, or intracellularly, either directly via chromate reductase enzymes, or indirectly via metabolite reduction of Cr(VI). The uptake of chromium ions is a biphasic process. The primary step is known as biosorption, a metabolic energyindependent process. Thereafter, bioaccumulation occurs, but is much slower, and is

  7. Modified Miniplates for Temporary Skeletal Anchorage in Orthodontics: Placement and Removal Surgeries

    Science.gov (United States)

    Cornelis, Marie A.; Scheffler, Nicole R.; Mahy, Pierre; Siciliano, Sergio; De Clerck, Hugo J.; Tulloch, J.F. Camilla

    2009-01-01

    Purpose Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons’ perceptions of their use. Patients and Methods We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. Results Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients’ chief complaint was swelling, lasting on average 5.3 ± 2.8 days after placement and 4.5 ± 2.6 days after removal. Conclusions Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment. PMID:18571028

  8. Designing Flightdeck Procedures: Literature Resources

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel; Degani, Asaf; Loukopoulou, Loukia; Mauro, Robert

    2017-01-01

    This technical publication contains the titles, abstracts, summaries, descriptions, and/or annotations of available literature sources on procedure design and development, requirements, and guidance. It is designed to provide users with an easy access to available resources on the topic of procedure design, and with a sense of the contents of these sources. This repository of information is organized into the following publication sources: Research (e.g., journal articles, conference proceedings), Manufacturers' (e.g., operation manuals, newsletters), and Regulatory and/or Government (e.g., advisory circulars, reports). An additional section contains synopses of Accident/Incident Reports involving procedures. This work directly supports a comprehensive memorandum by Barshi, Mauro, Degani, & Loukopoulou (2016) that summarizes the results of a multi-year project, partially funded by the FAA, to develop technical reference materials that support guidance on the process of developing cockpit procedures (see "Designing Flightdeck Procedures" https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20160013263.pdf). An extensive treatment of this topic is presented in a forthcoming book by the same authors.

  9. Capital Investment Procedures for FEMYSO

    OpenAIRE

    Oluduro, Francis Oladele; Duru, Longinus; Al Jaafar, Mofid

    2008-01-01

    Date: 2008-06-05 Level: Bachelor Thesis in Business Administration EF0703, 15 ECTS Credits. Authors: Longinus Duru (Stockholm), Francis O.Oluduro (Västerås) and Mofid Al Jaafar (Västerås) Title: Capital Investment Procedures for FEMYSO Problem Area: Undertaking an investment by FEMYSO involves weighing up the risk against the returns but still capital investment decision are still one of the most undertaken decisions by organization managers because it involves commitment of huge amount of mo...

  10. Method for removal of beryllium contamination from an article

    Science.gov (United States)

    Simandl, Ronald F.; Hollenbeck, Scott M.

    2012-12-25

    A method of removal of beryllium contamination from an article is disclosed. The method typically involves dissolving polyisobutylene in a solvent such as hexane to form a tackifier solution, soaking the substrate in the tackifier to produce a preform, and then drying the preform to produce the cleaning medium. The cleaning media are typically used dry, without any liquid cleaning agent to rub the surface of the article and remove the beryllium contamination below a non-detect level. In some embodiments no detectible residue is transferred from the cleaning wipe to the article as a result of the cleaning process.

  11. Procedural Skills Education – Colonoscopy as a Model

    Directory of Open Access Journals (Sweden)

    Maitreyi Raman

    2008-01-01

    Full Text Available Traditionally, surgical and procedural apprenticeship has been an assumed activity of students, without a formal educational context. With increasing barriers to patient and operating room access such as shorter work week hours for residents, and operating room and endoscopy time at a premium, alternate strategies to maximizing procedural skill development are being considered. Recently, the traditional surgical apprenticeship model has been challenged, with greater emphasis on the need for surgical and procedural skills training to be more transparent and for alternatives to patient-based training to be considered. Colonoscopy performance is a complex psychomotor skill requiring practioners to integrate multiple sensory inputs, and involves higher cortical centres for optimal performance. Colonoscopy skills involve mastery in the cognitive, technical and process domains. In the present review, we propose a model for teaching colonoscopy to the novice trainee based on educational theory.

  12. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  13. Sepsis and multiorgan failure following TVT procedure.

    Science.gov (United States)

    Stec, Piotr; Connell, Rowan

    2014-04-01

    Tension-free vaginal tape (TVT), is a commonly performed, low risk procedure for treatment of stress urinary incontinence (SUI). Severe complications are rare, but can be potentially life threatening. We present a case of 66 year old patient who sustained bladder perforation at the time of TVT procedure and subsequently developed sepsis rapidly leading to multi-organ failure and triggering sequence of serious complications. During her inpatient stay she required ITU admission, emergency laparotomy, TVT mesh removal, bowel resection due to ischemic colitis and anticoagulation for pulmonary embolism. Despite of clinical picture of sepsis her microbiology tests were almost consistently negative. This case emphasise importance of awareness and quick recognition of TVT related complications. Patient ultimately survived and recovered thanks to timely and coordinated management by the multidisciplinary team of doctors.

  14. Trends in Medicare Reimbursement for Orthopedic Procedures: 2000 to 2016.

    Science.gov (United States)

    Eltorai, Adam E M; Durand, Wesley M; Haglin, Jack M; Rubin, Lee E; Weiss, Arnold-Peter C; Daniels, Alan H

    2018-03-01

    Understanding trends in reimbursement is critical to the financial sustainability of orthopedic practices. Little research has examined physician fee trends over time for orthopedic procedures. This study evaluated trends in Medicare reimbursements for orthopedic surgical procedures. The Medicare Physician Fee Schedule was examined for Current Procedural Terminology code values for the most common orthopedic and nonorthopedic procedures between 2000 and 2016. Prices were adjusted for inflation to 2016-dollar values. To assess mean growth rate for each procedure and subspecialty, compound annual growth rates were calculated. Year-to-year dollar amount changes were calculated for each procedure and subspecialty. Reimbursement trends for individual procedures and across subspecialties were compared. Between 2000 and 2016, annual reimbursements decreased for all orthopedic procedures examined except removal of orthopedic implant. The orthopedic procedures with the greatest mean annual decreases in reimbursement were shoulder arthroscopy/decompression, total knee replacement, and total hip replacement. The orthopedic procedures with the least annual reimbursement decreases were carpal tunnel release and repair of ankle fracture. Rate of Medicare procedure reimbursement change varied between subspecialties. Trauma had the smallest decrease in annual change compared with spine, sports, and hand. Annual reimbursement decreased at a significantly greater rate for adult reconstruction procedures than for any of the other subspecialties. These findings indicate that reimbursement for procedures has steadily decreased, with the most rapid decrease seen in adult reconstruction. [Orthopedics. 2018; 41(2):95-102.]. Copyright 2018, SLACK Incorporated.

  15. Hair Removal

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Hair Removal KidsHealth / For Teens / Hair Removal What's in ... you need any of them? Different Types of Hair Before removing hair, it helps to know about ...

  16. Procedural learning and dyslexia.

    Science.gov (United States)

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. 2010 John Wiley & Sons, Ltd.

  17. Kinetics of Cr(III) and Cr(VI) removal from water by two floating macrophytes.

    Science.gov (United States)

    Maine, M A; Hadad, H R; Sánchez, G; Caffaratti, S; Pedro, M C

    2016-01-01

    The aim of this work was to compare Cr(III) and Cr(VI) removal kinetics from water by Pistia stratiotes and Salvinia herzogii. The accumulation in plant tissues and the effects of both Cr forms on plant growth were also evaluated. Plants were exposed to 2 and 6 mg L(-1) of Cr(III) or Cr(VI) during 30 days. At the end of the experiment, Cr(VI) removal percentages were significantly lower than those obtained for Cr(III) for both macrophytes. Cr(III) removal kinetics involved a fast and a slow component. The fast component was primarily responsible for Cr(III) removal while Cr(VI) removal kinetics involved only a slow process. Cr accumulated principally in the roots. In the Cr(VI) treatments a higher translocation from roots to aerial parts than in Cr(III) treatments was observed. Both macrophytes demonstrated a high ability to remove Cr(III) but not Cr(VI). Cr(III) inhibited the growth at the highest studied concentration of both macrophytes while Cr(VI) caused senescence. These results have important implications in the use of constructed wetlands for secondary industrial wastewater treatment. Common primary treatments of effluents containing Cr(VI) consists in its reduction to Cr(III). Cr(III) concentrations in these effluents are normally below the highest studied concentrations in this work.

  18. Obliged Removal of the Percutaneous Fixation System on the Thoracolumbar Junction in Patients with Idiopathic Scoliosis

    Directory of Open Access Journals (Sweden)

    Alessandro Landi

    2016-12-01

    Full Text Available Introduction Minimally invasive percutaneous surgery of the spine is used to treat thoracolumbar junction and lumbar spine fractures by percutaneous fixation. Once fusion has been obtained, it is possible to remove the percutaneous instrumentation after 6 - 12 months. We report the case of an obliged removal of the fixation system at 12 months following operation in a patient with a pre-existing compensated and asymptomatic idiopathic scoliosis. Case Presentation A 48-year-old patient affected by a compensated asymptomatic idiopathic scoliosis with an L3 type A3 fracture. The patient underwent a percutaneous short fixation L2 - L4. In the following months the patient presented progressive worsening of the low back pain and walking difficulties. The percutaneous fixation system was then removed using the same surgical access. Conclusions This particular case explains well the importance of biomechanical balance when a spinal fixation should be perform, and demonstrate how an underestimation of this aspect may cause a worsening of symptoms even if the surgical procedure was correctly performed. It is evident that the removal procedure can lead clinical benefit to a patient, in which the fixation system created a decompensation of the curvature of the spine, thus causing biomechanical alterations and generating pain. In these cases, it may be opportune to limit the fracture reduction during the surgical procedure to modify the least possible the pre-existing scoliosis and to increase the patient’s comfort after the operation. The biomechanical behaviour of the spine is specific for each patient so only a careful detection of it could lead to an optimal therapeutic result.

  19. Technical and surgical aspects of the sphenopalatine ganglion (SPG) microstimulator insertion procedure

    DEFF Research Database (Denmark)

    Assaf, A T; Hillerup, S; Rostgaard, J

    2016-01-01

    into the pterygopalatine fossa (PPF) is presented herein. Technical aspects include detailed descriptions of the preoperative planning using computed tomography or cone beam computed tomography scans for presurgical digital microstimulator insertion into the patient-specific anatomy and intraoperative verification......), and removal (n=5). This SPG microstimulator insertion procedure has sequelae comparable to other oral cavity procedures including tooth extractions, sinus surgery, and dental implant placement. Twenty-five of 29 subjects (86%) completing a self-assessment questionnaire indicated that the surgical effects were...

  20. Arabidopsis thaliana WAPL is essential for the prophase removal of cohesin during meiosis.

    Directory of Open Access Journals (Sweden)

    Kuntal De

    2014-07-01

    Full Text Available Sister chromatid cohesion, which is mediated by the cohesin complex, is essential for the proper segregation of chromosomes in mitosis and meiosis. The establishment of stable sister chromatid cohesion occurs during DNA replication and involves acetylation of the complex by the acetyltransferase CTF7. In higher eukaryotes, the majority of cohesin complexes are removed from chromosomes during prophase. Studies in fly and human have shown that this process involves the WAPL mediated opening of the cohesin ring at the junction between the SMC3 ATPase domain and the N-terminal domain of cohesin's α-kleisin subunit. We report here the isolation and detailed characterization of WAPL in Arabidopsis thaliana. We show that Arabidopsis contains two WAPL genes, which share overlapping functions. Plants in which both WAPL genes contain T-DNA insertions show relatively normal growth and development but exhibit a significant reduction in male and female fertility. The removal of cohesin from chromosomes during meiotic prophase is blocked in Atwapl mutants resulting in chromosome bridges, broken chromosomes and uneven chromosome segregation. In contrast, while subtle mitotic alterations are observed in some somatic cells, cohesin complexes appear to be removed normally. Finally, we show that mutations in AtWAPL suppress the lethality associated with inactivation of AtCTF7. Taken together our results demonstrate that WAPL plays a critical role in meiosis and raises the possibility that mechanisms involved in the prophase removal of cohesin may vary between mitosis and meiosis in plants.

  1. Episodic memory deficits slow down the dynamics of cognitive procedural learning in normal ageing

    Science.gov (United States)

    Beaunieux, Hélène; Hubert, Valérie; Pitel, Anne Lise; Desgranges, Béatrice; Eustache, Francis

    2009-01-01

    Cognitive procedural learning is characterized by three phases, each involving distinct processes. Considering the implication of the episodic memory in the first cognitive stage, the impairment of this memory system might be responsible for a slowing down of the cognitive procedural learning dynamics in the course of aging. Performances of massed cognitive procedural learning were evaluated in older and younger participants using the Tower of Toronto task. Nonverbal intelligence and psychomotor abilities were used to analyze procedural dynamics, while episodic memory and working memory were assessed to measure their respective contributions to learning strategies. This experiment showed that older participants did not spontaneously invoke episodic memory and presented a slowdown in the cognitive procedural learning associated with a late involvement of working memory. These findings suggest that the slowdown in the cognitive procedural learning may be linked with the implementation of different learning strategies less involving episodic memory in older subjects. PMID:18654928

  2. Premenarchal vaginal discharge: findings of procedures to rule out foreign bodies.

    Science.gov (United States)

    Smith, Yolanda R; Berman, Deborah R; Quint, Elisabeth H

    2002-08-01

    Vaginal discharge in children is a common gynecologic complaint and may be resistant to symptomatic and/or antibiotic treatment. In recurrent or unresponsive patients, an evaluation to rule out a foreign body is traditionally recommended. The objective of this study is to review cases of vaginal discharge referred to our institution and assess outcome and diagnosis in those who required irrigation or vaginoscopy to rule out a foreign body.A retrospective chart review was performed on all premenarchal girls identified through the University of Michigan Pediatric and Adolescent Gynecology Clinic database who were seen for evaluation of vaginal discharge between June 1996 and December 2001. The records were reviewed for age, length of time of discharge, aspects of discharge, procedures done to rule out foreign bodies, and findings of such procedures. The study was performed in a tertiary care university hospital. Forty-one premenarchal girls were evaluated for vaginal discharge. The average age was 6.0 yr (range 3 months-11 yr). The average duration of vaginal discharge prior to presentation was 13.7 months (range 1-42 months). Of the 41 girls, 18 girls underwent 1 procedure each, 2 girls underwent 2 procedures each, and 1 girl underwent 5 procedures. Ten vaginal irrigations in clinic were performed in 7 girls, 3 by the referring physician and 7 by us. These irrigations removed a foreign body (tissue paper) in 4 of 10 (40%) cases, 3 at our institution and 1 at an outside institution. In the three irrigation cases with foreign bodies performed at our institution, the foreign body was visible on genital examination prior to the irrigation. Seventeen vaginoscopies under anesthesia were performed in 16 girls, 5 by the referring physician and 12 by us. In the girls who underwent a vaginoscopy under anesthesia a foreign body was found in 3 of 17 (17.6%). The other findings of the vaginoscopies included: biopsy-proven severe dermatitis with no infection in 1 patient

  3. Safety and application of procedures or: how do ''they'' have to use operating procedures in nuclear power plants

    International Nuclear Information System (INIS)

    Dien, Y.

    1993-03-01

    Emergency procedures are inescapable aspects of safety. They can be seen as the laws to be respected in an accident situation. But as for all laws, there remains the problem of their application: should strict adherence to the procedure be imposed under all circumstances. Is this possible. Are there any potential risks with such a requirement. Or, on the contrary, should application be more ''open'', more flexible, allowing for adaptation to the actual situation. But what are the potential risks involved in this approach. Are these two approaches to the application of procedures mutually exclusive, or are they complementary. This paper analyzes the nature of the problem of application of procedures and proposes orientations for further thought on the matter. (author). 11 refs

  4. Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure.

    Science.gov (United States)

    Harima, Hirofumi; Hamabe, Kouichi; Hisano, Fusako; Matsuzaki, Yuko; Itoh, Tadahiko; Sanuki, Kazutoshi; Sakaida, Isao

    2018-05-23

    An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

  5. The removal of uranium from mining waste water using algal/microbial biomass

    International Nuclear Information System (INIS)

    Kalin, Margarete; Wheeler, W.N.; Meinrath, G.

    2004-01-01

    We describe a three step process for the removal of uranium (U) from dilute waste waters. Step one involves the sequestration of U on, in, and around aquatic plants such as algae. Cell wall ligands efficiently remove U(VI) from waste water. Growing algae continuously renew the cellular surface area. Step 2 is the removal of U-algal particulates from the water column to the sediments. Step 3 involves reducing U(VI) to U(IV) and transforming the ions into stable precipitates in the sediments. The algal cells provide organic carbon and other nutrients to heterotrophic microbial consortia to maintain the low E H , within which the U is transformed. Among the microorganisms, algae are of predominant interest for the ecological engineer because of their ability to sequester U and because some algae can live under many extreme environments, often in abundance. Algae grow in a wide spectrum of water qualities, from alkaline environments (Chara, Nitella) to acidic mine drainage waste waters (Mougeotia, Ulothrix). If they could be induced to grow in waste waters, they would provide a simple, long-term means to remove U and other radionuclides from U mining effluents. This paper reviews the literature on algal and microbial adsorption, reduction, and transformation of U in waste streams, wetlands, lakes and oceans

  6. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    Science.gov (United States)

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Empirical testing of forecast update procedure forseasonal products

    DEFF Research Database (Denmark)

    Wong, Chee Yew; Johansen, John

    2008-01-01

    Updating of forecasts is essential for successful collaborative forecasting, especially for seasonal products. This paper discusses the results of a theoretical simulation and an empirical test of a proposed time-series forecast updating procedure. It involves a two-stage longitudinal case study...... of a toy supply chain. The theoretical simulation involves historical weekly consumer demand data for 122 toy products. The empirical test is then carried out in real-time with 291 toy products. The results show that the proposed forecast updating procedure: 1) reduced forecast errors of the annual...... provided less forecast accuracy improvement and it needed a longer time to achieve relatively acceptable forecast uncertainty....

  8. Arsenic and iron removal from groundwater by oxidation–coagulation at optimized pH: Laboratory and field studies

    International Nuclear Information System (INIS)

    Bordoloi, Shreemoyee; Nath, Suresh K.; Gogoi, Sweety; Dutta, Robin K.

    2013-01-01

    Highlights: • Arsenic and iron removed by a systematic oxidation–coagulation at optimized pH. • Used KMnO 4 as oxidant and FeCl 3 as coagulant in presence of NaHCO 3 . • Field trial results are highly encouraging. • The method is efficient, safe, simple and low-cost. • The method is suitable for rural application in developing countries. -- Abstract: A three-step treatment process involving (i) mild alkaline pH-conditioning by NaHCO 3 ; (ii) oxidation of arsenite and ferrous ions by KMnO 4 , itself precipitating as insoluble MnO 2 under the pH condition; and (iii) coagulation by FeCl 3 has been used for simultaneous removal of arsenic and iron ions from water. The treated water is filtered after a residence time of 1–2 h. Laboratory batch experiments were performed to optimize the doses. A field trial was performed with an optimized recipe at 30 households and 5 schools at some highly arsenic affected villages in Assam, India. Simultaneous removals of arsenic from initial 0.1–0.5 mg/L to about 5 μg/L and iron from initial 0.3–5.0 mg/L to less than 0.1 mg/L have been achieved along with final pH between 7.0 and 7.5 after residence time of 1 h. The process also removes other heavy elements, if present, without leaving any additional toxic residue. The small quantity of solid sludge containing mainly ferrihydrite with adsorbed arsenate passes the toxicity characteristic leaching procedure (TCLP) test. The estimated recurring cost is approximately USD 0.16 per/m 3 of purified water. A high efficiency, an extremely low cost, safety, non-requirement of power and simplicity of operation make the technique potential for rural application

  9. Arsenic and iron removal from groundwater by oxidation–coagulation at optimized pH: Laboratory and field studies

    Energy Technology Data Exchange (ETDEWEB)

    Bordoloi, Shreemoyee; Nath, Suresh K.; Gogoi, Sweety; Dutta, Robin K., E-mail: robind@tezu.ernet.in

    2013-09-15

    Highlights: • Arsenic and iron removed by a systematic oxidation–coagulation at optimized pH. • Used KMnO{sub 4} as oxidant and FeCl{sub 3} as coagulant in presence of NaHCO{sub 3}. • Field trial results are highly encouraging. • The method is efficient, safe, simple and low-cost. • The method is suitable for rural application in developing countries. -- Abstract: A three-step treatment process involving (i) mild alkaline pH-conditioning by NaHCO{sub 3}; (ii) oxidation of arsenite and ferrous ions by KMnO{sub 4}, itself precipitating as insoluble MnO{sub 2} under the pH condition; and (iii) coagulation by FeCl{sub 3} has been used for simultaneous removal of arsenic and iron ions from water. The treated water is filtered after a residence time of 1–2 h. Laboratory batch experiments were performed to optimize the doses. A field trial was performed with an optimized recipe at 30 households and 5 schools at some highly arsenic affected villages in Assam, India. Simultaneous removals of arsenic from initial 0.1–0.5 mg/L to about 5 μg/L and iron from initial 0.3–5.0 mg/L to less than 0.1 mg/L have been achieved along with final pH between 7.0 and 7.5 after residence time of 1 h. The process also removes other heavy elements, if present, without leaving any additional toxic residue. The small quantity of solid sludge containing mainly ferrihydrite with adsorbed arsenate passes the toxicity characteristic leaching procedure (TCLP) test. The estimated recurring cost is approximately USD 0.16 per/m{sup 3} of purified water. A high efficiency, an extremely low cost, safety, non-requirement of power and simplicity of operation make the technique potential for rural application.

  10. Licensing procedures for Low-Level Waste disposal facilities

    Energy Technology Data Exchange (ETDEWEB)

    Roop, R.D.; Van Dyke, J.W.

    1985-09-01

    This report describes the procedures applicable to siting and licensing of disposal facilities for low-level radioactive wastes. Primary emphasis is placed on those procedures which are required by regulations, but to the extent possible, non-mandatory activities which will facilitate siting and licensing are also considered. The report provides an overview of how the procedural and technical requirements for a low-level waste (LLW) disposal facility (as defined by the Nuclear Regulatory Commission's Rules 10 CFR Parts 2, 51, and 61) may be integrated with activities to reduce and resolve conflict generated by the proposed siting of a facility. General procedures are described for site screening and selection, site characterization, site evaluation, and preparation of the license application; specific procedures for several individual states are discussed. The report also examines the steps involved in the formal licensing process, including docketing and initial processing, preparation of an environmental impact statement, technical review, hearings, and decisions. It is concluded that development of effective communication between parties in conflict and the utilization of techniques to manage and resolve conflicts represent perhaps the most significant challenge for the people involved in LLW disposal in the next decade. 18 refs., 6 figs.

  11. Our first experiences in applying an original method for removal of ABO-isoagglutinins in ABO-incompatible kidney recipients

    Directory of Open Access Journals (Sweden)

    Ignjatović Ljiljana

    2009-01-01

    Full Text Available Background/Aim. Due to improved methods for removal of ABO isoagglutinins and novel immunosuppressive protocols, short and long term outcome in blood group incompatible is similar to blood group compatible kidney transplantation. The aim of this study was to determine the efficacy of our original method for removal of ABO isoagglutinins from the blood in ABO-incompatible kidney allograft recipients. Method. Between 2006 and 2008 twelve patients were transplanted from ABO incompatible living donors. Titers of ABO isoagglutinins were 4-128 (IgG. Immunosuppressive therapy started 14 days before kidney transplantation with rituximab, followed by a triple therapy (prednisone + tacrolimus + mycophenolate mofetil and the first plasma exchange (PE procedure, in which one plasma volume was substituted with albumin and saline on day 7 before transplantation. For selective extracorporeal immunoadsorption, the removed plasma was mixed with donor blood type filtered red blood cells, centrifuged and the supernatant separated and preserved. In the next PE procedure, the removed plasma was replaced with immunoadsorbed plasma, and so on. Titers of ABO agglutinins, renal allograft function and survival were followed-up. Results. The pre-transplant treatment consisting of 1-5 PE procedures and immunosuppressive therapy resulted in target ABO agglutinins titers below 4. During a 10-24 month follow-up three patients had an early acute rejection, one patient acute rejection and hemolytic anemia, two patients surgical complications and one of them lost his graft. In the post-transplant period, the titers of ABO antibodies remained below 4. All the patients had stable kidney allograft function with mean serum creatinine ±SD of 129 ± 45 μmol/l at the end of the study. Conclusion. Our method for removal of ABO antibodies was effective in a limited series of patients and short-term follow-up.

  12. Strategy Innovation with Employee Involvement

    DEFF Research Database (Denmark)

    Friis, Ole Uhrskov; Koch, Christian

    2015-01-01

    The purpose of this article is to investigate how employees can be involved in strategy innovation processes and how new strategy practices (new tools and procedures) are used to change strategy praxis in order to sustain value creation. In the strategizing actions, we found that even...... if the managers still dominate, some processes of direct involvement of employees occur, in particular when employees are asked to supplement overall strategic goals and when they directly shape several sub-strategies. Strategy practices found include strategy planning, an open space workshop and organised...... strategy projects. Especially the latter two are important in facilitating the employee involvement. The case, however, also exhibits enterprise-situated praxises related to unplanned events, like the mitigation of taboos....

  13. Comparison of Electrocoagulation and Chemical Coagulation Processes in Removing Reactive red 196 from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Ali Assadi

    2016-06-01

    Full Text Available Background: Conventional chemical coagulation is considered as an old method to dye and COD removal in textile effluent. Electrocoagulation (EC process is a robust method to achieve maximum removal. Methods: This study was designed to compare the result of operational parameters including optimum pH and coagulant concentration for chemical coagulation with ferric chloride and alum also, voltage, electrolysis time, initial pH, and conductivity for EC with iron electrodes to remove reactive red 196 (RR 196. Results: The outcomes show that ferric chloride and alum at optimum concentration were capable of removing dye and COD by 79.63 % and 84.83% and 53% and 55%, respectively. In contrast, EC process removed the dye and COD by 99.98% and 90.4%, respectively. Conclusion: The highest treatment efficiency was obtained by increasing the voltage, electrolysis time, pH and conductivity. Increase initial dye concentration reduces removal efficiency. Ultimately, it could be concluded that EC technology is an efficient procedure for handling of colored industrial wastewaters.

  14. Laparoscopic sentinel lymph node procedure using a combination of patent blue and radioisotope in women with cervical carcinoma.

    Science.gov (United States)

    Barranger, Emmanuel; Grahek, Dany; Cortez, Annie; Talbot, Jean Noel; Uzan, Serge; Darai, Emile

    2003-06-15

    The authors evaluated the feasibility of a laparoscopic sentinel lymph node (SN) procedure with combined radioisotopic and patent blue labeling in patients with cervical carcinoma. Thirteen women (median age, 52.5 years) with cervical carcinoma (Stage Ia2 in 1 patient, Stage Ib1 in 10 patients, Stage Ib2 in 1 patient, and Stage IIa in 1 patient) underwent a laparoscopic SN procedure using an endoscopic gamma probe after both radioactive isotope and patent blue injections. After the procedure, all patients underwent complete laparoscopic pelvic lymphadenectomy and either laparoscopic radical hysterectomy (eight patients) or the Schauta-Amreich operation (five patients). SNs (mean, 1.7 SNs per patient; range, 1-3 SNs per patient) were identified in 12 of 13 patients. A median of 10.5 pelvic lymph nodes per patient (range, 4-17 pelvic lymph nodes per patient) were removed. No lymph node involvement was detected in SNs with hematoxylin and eosin staining. Immunohistochemical studies identified four metastatic SNs in two patients, with micrometastases in two SNs from the first patient and isolated tumor cells in two SNs from the second patient. No false-negative SN results were obtained. The results of this study suggest that SN detection with a combination of radiocolloid and patent blue is feasible in patients with cervical carcinoma. The combination of laparoscopy and the SN procedure permitted minimally invasive management of early-stage disease. Copyright 2003 American Cancer Society.

  15. Cadmium ion removal using biosorbents derived from fruit peel wastes

    Directory of Open Access Journals (Sweden)

    Wanna Saikaew

    2009-11-01

    Full Text Available The ability of fruit peel wastes, corn, durian, pummelo, and banana, to remove cadmium ions from aqueous solution by biosorption were investigated. The experiments were carried out by batch method at 25oC. The influence of particle sizes, solution pH, and initial cadmium ion concentrations were evaluated on the biosorption studies. The result showed that banana peel had the highest cadmium ions removal followed by durian, pummelo, and corn peels at cadmium ions removal of 73.15, 72.17, 70.56, and 51.22%, respectively. There was a minimal effect when using different particle sizes of corn peel as biosorbent, while the particle size of the others had no influence on the removal of cadmium ions. The cadmium ions removal increased significantly as the pH of the solution increased rapidly from 1 to 5. At pH 5, the cadmium ions removal reached a maximum value. The equilibrium process was best described by the Langmuir isotherms, with maximum biosorption capacities of durian, pummelo, and banana peel of 18.55, 21.83, and 20.88 mg/g respectively. Fourier Transform Infrared Spectroscopy revealed that carboxyl, hydroxyl, and amide groups on the fruit peels’ surface and these groups were involved in the adsorption of the cadmium ions.

  16. Cesium removal from liquid acidic wastes with the primary focus on ammonium molybdophosphate as an ion exchanger: A literature review

    International Nuclear Information System (INIS)

    Miller, C.J.

    1995-03-01

    Many articles have been written concerning the selective removal of cesium from both acidic and alkaline defense wastes. The majority of the work performed for cesium removal from defense wastes involves alkaline feed solutions. Several different techniques for cesium removal from acidic solutions have been evaluated such as precipitation, solvent extraction, and ion exchange. The purpose of this paper is to briefly review various techniques for cesium removal from acidic solutions. The main focus of the review will be on ion exchange techniques, particularly those involving ammonium molybdophosphate as the exchanger. The pertinent literature sources are condensed into a single document for quick reference. The information contained in this document was used as an aid in determining techniques to evaluate cesium removal from the acidic Idaho Chemical Processing Plant waste matrices. 47 refs., 2 tabs

  17. User Oriented Climatic Information for Planning a Snow Removal Budget.

    Science.gov (United States)

    Cohen, Stewart J.

    1981-12-01

    Many activities associated with the transportation sector are weather sensitive. This study is concerned with highway maintenance activities, specifically snow removal, and the budgeting of same by the Illinois Department of Transportation (IDOT). During the 1978-79 winter, IDOT's snow removal budget was exhausted by the end of January, thereby necessitating the procurement of emergency funds. The following year, the Illinois State Water Survey (ISWS) was asked to provide specialized climatic design information that could be used to assist IDOT in its budget planning for snow removal.Snow removal is often accomplished by spreading road salt over snow- and ice-covered roads, thus improving traction and reducing the risk of vehicles skidding along slippery surfaces. This study demonstrates the computation of `salt days,' a user-oriented climatic variable that indicates the number of days when road salt is required. This variable is defined using certain temperature and snowfall criteria. Results of a pilot study indicate that it is possible to provide statistical outlooks for salt days two months in advance, using correlation analysis. The analysis for several Illinois stations indicates that at various intervals in the data records, November and December temperatures are significantly correlated with February salt days if short periods of record (5-20 years) are used.IDOT originally requested a `2- to 3-month projection.' However, it became clear that only projections of 12 months or longer could benefit annual budget preparation. Confusion existed between the user and the supplier of climatic information regarding the user's needs, and the applicability of the supplier's `climate products' to the user's budget planning procedure. This demonstrates the need for a prolonged effort by the supplier to fully acquaint the user with the various forms of climatic information available. This gap in communication must be overcome so that applied climatology can be integrated

  18. Risk Control Through the Use of Procedures - A Method for Evaluating the Change in Risk

    Science.gov (United States)

    Praino, Gregory; Sharit, Joseph

    2010-01-01

    Organizations use procedures to influence or control the behavior of their workers, but often have no basis for determining whether an additional rule, or procedural control will be beneficial. This paper outlines a proposed method for determining if the addition or removal of procedural controls will impact the occurrences of critical consequences. The proposed method focuses on two aspects: how valuable the procedural control is, based on the inevitability of the consequence and the opportunity to intervene; and how likely the control is to fail, based on five procedural design elements that address how well the rule or control has been Defined, Assigned, Trained, Organized and Monitored-referred to as the DATOM elements

  19. New and Advanced Picosecond Lasers for Tattoo Removal.

    Science.gov (United States)

    Adatto, Maurice A; Amir, Ruthie; Bhawalkar, Jayant; Sierra, Rafael; Bankowski, Richard; Rozen, Doran; Dierickx, Christine; Lapidoth, Moshe

    2017-01-01

    Early methods of tattoo removal ultimately resulted in unacceptable cosmetic outcomes. While the introduction of laser technology was an improvement over the existing chemical, mechanical, and surgical procedures, the use of nonselective tattoo removal with carbon dioxide and argon lasers led to scarring. Q-switched lasers with nanosecond (10-9) pulse domains were considered to have revolutionized tattoo treatment, by selectively heating the tattoo particles, while reducing the adverse sequelae to adjacent normal skin. Theoretical considerations of restricting pulse duration, to heat tattoo particles to higher temperatures, proposed the use of sub-nanosecond pulses to target particles with thermal relaxation times lower than the nanosecond pulses in Q-switched lasers. Initial studies demonstrated that picosecond (10-12) pulses were more effective than nanosecond pulses in clearing black tattoos. Advances in picosecond technology led to the development of commercially available lasers, incorporating several different wavelengths, to further refine pigment targeting. © 2017 S. Karger AG, Basel.

  20. Implicit Procedural Learning in Fragile X and Down Syndrome

    Science.gov (United States)

    Bussy, G.; Charrin, E.; Brun, A.; Curie, A.; des Portes, V.

    2011-01-01

    Background: Procedural learning refers to rule-based motor skill learning and storage. It involves the cerebellum, striatum and motor areas of the frontal lobe network. Fragile X syndrome, which has been linked with anatomical abnormalities within the striatum, may result in implicit procedural learning deficit. Methods: To address this issue, a…

  1. Hydrogen Peroxide Enhances Removal of NOx from Flue Gases

    Science.gov (United States)

    Collins, Michelle M.

    2005-01-01

    Pilot scale experiments have demonstrated a method of reducing the amounts of oxides of nitrogen (NOx) emitted by industrial boilers and powerplant combustors that involves (1) injection of H2O2 into flue gases and (2) treatment of the flue gases by caustic wet scrubbing like that commonly used to remove SO2 from combustion flue gases. Heretofore, the method most commonly used for removing NOx from flue gases has been selective catalytic reduction (SCR), in which the costs of both installation and operation are very high. After further development, the present method may prove to be an economically attractive alternative to SCR.

  2. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    Science.gov (United States)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  3. Extended Endoscopic Endonasal Approach for Craniopharyngioma Removal.

    Science.gov (United States)

    Messerer, Mahmoud; Maduri, Rodolfo; Daniel, Roy Thomas

    2018-02-01

    Objective  Endoscopic transsphenoidal extended endoscopic approach (EEA) represents a valid alternative to microsurgery for craniopharyngiomas removal, especially for retrochiasmatic lesions without large parasellar extension. The present video illustrates the salient surgical steps of the EEA for craniopahryngioma removal. Patient  A 52-year-old man presented with a bitemporal hemianopia and a bilateral decreased visual acuity. MRI showed a Kassam type III cystic craniopharyngioma with a solid component ( Fig. 1 , panels A and B). Surgical Procedure  The head is rotated 10 degrees toward the surgeons. The nasal step is started through the left nostril with a middle turbinectomy. A nasoseptal flap is harvested and positioned in the left choana. The binostril approach allows a large sphenoidotomy to expose the key anatomic landmarks. The craniotomy boundaries are the planum sphenoidale superiorly, the median opticocarotid recesses, the internal carotid artery laterally and the clival recess inferiorly. After dural opening and superior intercavernous sinus coagulation, the tumor is entirely removed ( Fig. 2 , panels A and B). Skull base reconstruction is ensured by fascia lata grafting and nasoseptal flap positioning. Results  Postoperative MRI showed the complete tumor resection ( Fig. 1 , panels C and D). At 3 months postoperatively, the bitemporal hemianopia regressed and the visual acuity improved. A novel left homonymous hemianopia developed secondary to optic tract manipulation. Conclusions  The extended EEA is a valid surgical approach for craniopharyngioma resection. A comprehensive knowledge of the sellar and parasellar anatomy is mandatory for safe tumor removal with decreased morbidity and satisfactory oncologic results. The link to the video can be found at: https://youtu.be/NrCPPnVK2qA .

  4. Cocaine Versus Food Choice Procedure in Rats: Environmental Manipulations and Effects of Amphetamine

    Science.gov (United States)

    Thomsen, Morgane; Barrett, Andrew C.; Negus, S. Stevens; Caine, S. Barak

    2014-01-01

    We have adapted a nonhuman primate model of cocaine versus food choice to the rat species. To evaluate the procedure, we tested cocaine versus food choice under a variety of environmental manipulations as well as pharmacological pretreatments. Complete cocaine-choice dose-effect curves (0–1.0 mg/kg/infusion) were obtained for each condition under concurrent fixed ratio schedules of reinforcement. Percentage of responding emitted on the cocaine-reinforced lever was not affected significantly by removal of cocaine-associated visual or auditory cues, but it was decreased after removal of response-contingent or response-independent cocaine infusions. Cocaine choice was sensitive to the magnitude and fixed ratio requirement of both the cocaine and food reinforcers. We also tested the effects of acute (0.32, 0.56, 1.0, 1.8 mg/kg) and chronic (0.1, 0.32 mg/kg/hr) d-amphetamine treatment on cocaine choice. Acute and chronic d-amphetamine had opposite effects, with acute increasing and chronic decreasing cocaine choice, similar to observations in humans and in nonhuman primates. The results suggest feasibility and utility of the choice procedure in rats and support its comparability to similar procedures used in humans and monkeys. PMID:23319458

  5. Removal effects of the Nd:YAG laser and Carisolv on carious dentin.

    Science.gov (United States)

    Yamada, Y; Hossain, M; Kawanaka, T; Kinoshita, J; Matsumoto, K

    2000-10-01

    The purpose of this study was to investigate the removal effect of the Nd:YAG laser irradiation and Carisolv on carious dentin. Many previous studies have reported several simple and alternative techniques, such as lasers and chemicals, for caries removal. Carisolv was applied on the surface of 20 extracted human anterior and molar teeth for 1 min and then the Nd:YAG laser was irradiated with a continuous water spray for another 1 min. The energy densities were varied from 2 to 6W with a repetition rate of 20 pps. As caries removal progressed, the cavity was carefully assessed by DIAGNOdent. Each lesion was photographed before and after treatment, and the treated cavity was observed microscopically using a stereoscope and with scanning electron microscope (SEM). Thermal change at the time of laser irradiation was measured by thermovision. Our results revealed that application of Carisolv followed by Nd:YAG laser irradiation at 4-6W pulse energy effectively removed dentin caries. The total procedure was usually repeated once or twice for complete caries removal. From the SEM study, it was found that the cavity surface treated with the laser revealed various patterns of microirregularity, often accompanied by microfissure propagation. There was also no smear layer. It was revealed that Nd:YAG laser and Carisolv could provide an alternative technique for caries removal instead of the conventional mechanical drilling and cutting.

  6. Use of Moringa oleifera seeds for the removal of turbidity of water supply

    Directory of Open Access Journals (Sweden)

    Gustavo Lopes Muniz

    2015-04-01

    Full Text Available Water used for human consumption may contain various impurities and solid particles in suspension that increase its turbidity level. Moringa oleifera Lam is a plant that has the potential to be used as coagulating agent in removing turbidity. The objective of this work was to evaluate the efficiency of Moringa oleifera seeds used in shells and without shells in the removal of turbidity from waters with different degrees of turbidity. Waters were used with 70, 250 and 400 initial NTU obtained synthetically. The extract of moringa seeds was prepared using unshelled and shelled seeds, seeking a simplified procedure and practice. The sedimentation times and dose of coagulant solution used were based on existing recommendations in the literature. All treatments were performed with three replicates and the averages depicted in graphs. The results showed that the use of extract of moringa seeds in shells was more efficient than with unshelled seeds in the removal of turbidity of all treatments and that the shelled seeds removed more than 99% of the initial turbidity of the water samples. Furthermore, there was a direct relationship between turbidity removal efficiency and the level of initial turbidity of the samples. The seeds were more efficient in removing turbidity of the water with a higher level of initial turbidity.

  7. The role of nitric oxide radicals in removal of hyper-radiosensitivity by priming irradiation

    International Nuclear Information System (INIS)

    Edin, Nina Jeppesen; Sandvik, Joe Alexander; Pettersen, Erik Olai; Vollan, Hilde Synnove; Reger, Katharina; Görlach, Agnes

    2013-01-01

    In this study, a mechanism in which low-dose hyper-radiosensitivity (HRS) is permanently removed, induced by low-dose-rate (LDR) (0.2 - 0.3 Gy/h for 1 h) but not by high-dose-rate priming (0.3 Gy at 40 Gy/h) was investigated. One HRS-negative cell line (NHIK 3025) and two HRS-positive cell lines (T-47D, T98G) were used. The effects of different pretreatments on HRS were investigated using the colony assay. Cell-based ELISA was used to measure nitric oxide synthase (NOS) levels, and microarray analysis to compare gene expression in primed and unprimed cells. The data show how permanent removal of HRS, previously found to be induced by LDR priming irradiation, can also be induced by addition of nitric oxide (NO)-donor DEANO combined with either high-dose-rate priming or exposure to prolonged cycling hypoxia followed by reoxygenation, a treatment not involving radiation. The removal of HRS appears not to involve DNA damage induced during priming irradiation as it was also induced by LDR irradiation of cell-conditioned medium without cells present. The permanent removal of HRS in LDR-primed cells was reversed by treatment with inducible nitric oxide synthase (iNOS) inhibitor 1400W. Furthermore, 1400W could also induce HRS in an HRS-negative cell line. The data suggest that LDR irradiation for 1 h, but not 15 min, activates iNOS, and also that sustained iNOS activation is necessary for the permanent removal of HRS by LDR priming. The data indicate that nitric oxide production is involved in the regulatory processes determining cellular responses to low-dose-rate irradiation. (author)

  8. Nitrogen removal from wastewater by a catalytic oxidation method.

    Science.gov (United States)

    Huang, T L; Macinnes, J M; Cliffe, K R

    2001-06-01

    The ammonia-containing waste produced in industries is usually characterized by high concentration and high temperature, and is not treatable by biological methods directly. In this study, a hydrophobic Pt/SDB catalyst was first used in a trickle-bed reactor to remove ammonia from wastewater. In the reactor, both stripping and catalytic oxidation occur simultaneously. It was found that higher temperature and higher oxygen partial pressure enhanced the ammonia removal. A reaction pathway, which involves oxidizing ammonia to nitric oxide, which then further reacts with ammonia to produce nitrogen and water, was confirmed. Small amounts of by-products, nitrites and nitrates were also detected in the resultant reaction solution. These compounds came from the absorption of nitrogen oxides. Both the minimum NO2- selectivity and maximum ammonia removal were achieved when the resultant pH of treated water was near 7.5 for a feed of unbuffered ammonia solution.

  9. Standard practice for fluorescent liquid penetrant testing using the Solvent-Removable process

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers procedures for fluorescent penetrant examination utilizing the solvent-removable process. It is a nondestructive testing method for detecting discontinuities that are open to the surface, such as cracks, seams, laps, cold shuts, laminations, isolated porosity, through leaks, or lack of fusion and is applicable to in-process, final, and maintenance examination. It can be effectively used in the examination of nonporous, metallic materials, both ferrous and nonferrous, and of nonmetallic materials such as glazed or fully densified ceramics and certain nonporous plastics and glass. 1.2 This practice also provides a reference: 1.2.1 By which a fluorescent penetrant examination solvent-removable process recommended or required by individual organizations can be reviewed to ascertain its applicability and completeness. 1.2.2 For use in the preparation of process specifications dealing with the fluorescent solvent-removable liquid penetrant examination of materials and parts. Agreement by th...

  10. [Anatomical and clinical evaluation regarding the removal of the peritoneal dialysis catheter].

    Science.gov (United States)

    Tăranu, T; Covic, A; Târcoveanu, E; Florea, Laura

    2005-01-01

    To describe CAPD technique survival and causes for catheter removal. The study included 320 end stage renal disease (ESRD) patients, initiated on CAPD between 1995-2003. Definitive catheter removal was required in 44 cases (15.1%), 11 of these (3.79%) receiving renal transplant. Causes for catheter removal were: mechanical obstruction by fibrin (8 cases/2.75%), obstruction by tub bower (1 case/0.34%), by omental muff (6 cases/2%); abdominal wall sepsis (30 cases/ 10.3%); non-responsive bacterial peritonitis (13 cases/4.05%), fungal peritonitis (7 cases/ 2.4%), fecal peritonitis (2 cases/0.68%); transfer to hemodialysis program (31 cases/10.6%); renal transplant (11 cases/3.79%); emergency surgical pathology for: necrotic-hemorrhagic pancreatitis (two cases), intestinal occlusions (six cases), locked hernias (three cases) and locked eventrations(three cases), appendicular peritonitis (two cases). Mortality associated with these procedures and underlying pathology was 1.73%.

  11. Procedures for, and Experiences in, Introducing Algebra in New South Wales.

    Science.gov (United States)

    Pegg, John; Redden, Edward

    1990-01-01

    Discussed are the philosophy and procedures behind the introduction of algebra to students in grade 7 in Australia. Included are the importance of concrete experiences, language development, and the consequences involved in this procedure. (CW)

  12. Short-term responses of decomposers and vegetation to stump removal

    Energy Technology Data Exchange (ETDEWEB)

    Kataja-aho, S.

    2011-07-01

    Stump removal has become a common practice to produce raw material for bioenergy production. It was hypothesized that stump removal is an extensive and more intense disturbance for forest ecosystems (soil decomposer organisms and vegetation) compared to traditional site preparation after clear cutting. Therefore, the effects of stump harvesting on forest soil decomposers, vegetation and nutrient dynamics in undisturbed patches of the forest soil and in exposed mineral soil were compared to the effects of the traditional site preparation method, mounding. Nematodes and enchytraeids were the only decomposer groups that were directly affected (negatively) by the stump removal. Regardless of the treatment, the abundances of most of the decomposer groups were consistently lower in the exposed mineral soil than in the intact forest soil. There was 2-3 times more exposed mineral soil in stump removal sites compared to mounding sites. When this was taken into account, the decomposer community was negatively affected by the stump removal at the forest stand level. However, the greater soil disturbance at the stump harvesting sites enhanced CO{sub 2} production, net nitrogen mineralisation and nitrification. The increased N availability and the changes in microclimate due to the disturbance probably explained the vegetation increase at the stump harvested sites. Planted Norway spruce seedlings grew faster during the first two growing periods at the stump removal sites than at the mounding sites. The seedlings had high and similar ectomycorrhizal colonization rate in both treatments. In the short-term, it is probably not the resources removed in the stumps themselves, but the degree and amount of soil disturbance during the stump harvesting procedure that affects the decomposer community and its function in the clear-felled stands. (orig.)

  13. Design of amphoteric chitosan flocculants for phosphate and turbidity removal in wastewater.

    Science.gov (United States)

    Agbovi, Henry K; Wilson, Lee D

    2018-06-01

    An amphoteric flocculant (CMC-CTA) was synthesized by grafting 3-chloro-2-hydroxypropyl trimethylammonium chloride onto carboxymethyl chitosan (CMC). The turbidity and orthophosphate (P i ) removal properties of chitosan (CHI), CMC, and CMC-CTA were compared in the presence (and absence) of FeCl 3 coagulant. At a fixed FeCl 3 dosage, the effects of flocculant dosage, pH and settling time were evaluated. Turbidity removal (%) and optimal dosage (FeCl 3 ; mg/L) was determined: CMC-CTA (95.8%;5), CHI (88.8%;7.0) and CMC (68.8%;9.0). The corresponding P i removal (%) and dosage (mg/L) are listed: (93.4%;10), (90.6%;10), and (67.4%;5). Optimal turbidity and P i removal occurred at pH 4, where CMC-CTA had greater efficiency over CMC and CHI. The turbidity removal kinetics was described by the pseudo-second-order model, while P i removal followed the pseudo-first-order model. The removal process involves cooperative Coulombic interactions between the biopolymer/Fe(III)/P i and/or kaolinite colloids, along with polymer bridging effects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. First response to transportation emergencies involving radioactive materials

    International Nuclear Information System (INIS)

    1994-01-01

    This FEMA/DOE/DOT videocourse describes the basis for procedures to be used by emergency first responders for transportation accidents which involve radioactive materials. Various commercial and government sector radioactive materials shipment programs will be described and will include information about hazards and the elements of safety, proper first response actions, notification procedures, and state or federal assistance during emergencies. Primary audience: fire service and emergency management personnel

  15. The bioactivation procedure for increasing the sulphate-reducing bacteria in a UASB reactor

    Directory of Open Access Journals (Sweden)

    M. M. M. Gonçalves

    2005-12-01

    Full Text Available Bioactivation, a procedure to obtain anaerobic sulphidogenic sludge, was developed in order to increase sulphate reduction and, consequently, sulphide production to remove metals from effluents. This procedure, in which the source of carbon/energy (lactate is gradually replaced, consisted of three operational conditions. It was observed that bioactivation took six months so there was a 100-fold increase in the population of sulphate-reducing bacteria estimated by the most-probable-number (MPN when molasses was employed as a new source.

  16. Chromium removal from tannery wastewater by using of flying ash

    International Nuclear Information System (INIS)

    Gil P, E.; Saldarriaga M, C.

    1998-01-01

    A simple and economic method to chromium removal from tannery wastewater by means of flying ash is presented. The chromium removal operation is a discontinuous process that involve the mass of flying ash, time of contact and temperature or ph as variables, their which are optimized through Box-Wilson type experimental design. The results were successful: From an initial fluid whit chromium concentration of 1850m ppm, final concentrations of 0.008 ppm and 0.5 ppm of Cr+3 and Cr+6 respectively were achieved. These post-treatment concentrations are into the approved range definite by Government's Laws to this waste type

  17. The impact of a medical procedure service on patient safety, procedure quality and resident training opportunities.

    Science.gov (United States)

    Tukey, Melissa H; Wiener, Renda Soylemez

    2014-03-01

    At some academic hospitals, medical procedure services are being developed to provide supervision for residents performing bedside procedures in hopes of improving patient safety and resident education. There is limited knowledge of the impact of such services on procedural complication rates and resident procedural training opportunities. To determine the impact of a medical procedure service (MPS) on patient safety and resident procedural training opportunities. Retrospective cohort analysis comparing characteristics and outcomes of procedures performed by the MPS versus the primary medical service. Consecutive adults admitted to internal medicine services at a large academic hospital who underwent a bedside medical procedure (central venous catheterization, thoracentesis, paracentesis, lumbar puncture) between 1 July 2010 and 31 December 2011. The primary outcome was a composite rate of major complications. Secondary outcomes included resident participation in bedside procedures and use of "best practice" safety process measures. We evaluated 1,707 bedside procedures (548 by the MPS, 1,159 by the primary services). There were no differences in the composite rate of major complications (1.6 % vs. 1.9 %, p = 0.71) or resident participation in bedside procedures (57.0 % vs. 54.3 %, p = 0.31) between the MPS and the primary services. Procedures performed by the MPS were more likely to be successfully completed (95.8 % vs. 92.8 %, p = 0.02) and to use best practice safety process measures, including use of ultrasound guidance when appropriate (96.8 % vs. 90.0 %, p = 0.0004), avoidance of femoral venous catheterization (89.5 vs. 82.7 %, p = 0.02) and involvement of attending physicians (99.3 % vs. 57.0 %, p < 0.0001). Although use of a MPS did not significantly affect the rate of major complications or resident opportunities for training in bedside procedures, it was associated with increased use of best practice safety process measures.

  18. 23 CFR 750.304 - State policies and procedures.

    Science.gov (United States)

    2010-04-01

    ...-oriented directional advertising. (7) Tourist-oriented directional advertising. (b) Programing. (1) A sign... one company or those located along a single route, all of the signs in a single county or other... removal on other than a Federal-aid primary route basis e.g., a countywide project or a project involving...

  19. 40 CFR 68.69 - Operating procedures.

    Science.gov (United States)

    2010-07-01

    ...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.69 Operating procedures. (a) The... presented by, the chemicals used in the process; (ii) Precautions necessary to prevent exposure, including... instructions for safely conducting activities involved in each covered process consistent with the process...

  20. Removal of radionuclides from the water-soluble fraction of Hanford nuclear defense wastes

    International Nuclear Information System (INIS)

    Strachan, D.M.; Schulz, W.W.

    1980-01-01

    The current Hanford Waste Management Program has operated since 1968 to remove the bulk of the long-lived heat emitters /sup 90/Sr and /sup 137/Cs from stored high-level wastes. The liquid waste remaining after removal of /sup 90/Sr and /sup 137/Cs is returned to underground tanks for eventual evaporation to damp solid salt cake. Approximately 95,000 m/sup 3/ of salt cake and 49,000 m/sup 3/ of ''sludge'' will eventually accumulate in approximately 50 underground single-shell tanks. One alternative for long-term management of high-level Hanford wastes involves retrieval, after a yet-to-be determined interim storage time, conversion to more immobile forms, and terminal storage in a suitable geologic repository. Another alternative for long-term management of salt cake and residual liquid involves removing most of the long-lived radionuclides and many of the shorter-lived ones from these wastes. This paper describes conditions and results of recent hot cell tests of the complete Hanford Radionuclide Removal Process. These advanced tests, made with actual residual liquid containing large concentrations of ethylenediaminetetracetic acid (EDTA) and other organic compounds, provided a rigorous and convincing proof of the process flowsheet. 16 refs

  1. Evaluation of the Periodontal Status of Abutment Teeth in Removable Partial Dentures.

    Science.gov (United States)

    Correia, André Ricardo Maia; da Silva Lobo, Fábio Daniel; Miranda, Mónica Célia Pereira; Framegas de Araújo, Filipe Miguel Soares; Santos Marques, Tiago Miguel

    2017-12-15

    The purpose of this study was to evaluate whether the use of removable partial dentures affects the periodontal status of abutment teeth. An observational cross-sectional study was done on a sample of patients rehabilitated with removable partial dentures (2010 to 2013). At a recall appointment, a clinical examination was done to collect data related to the rehabilitation and periodontal status of the abutment teeth. Of 145 invited patients, 54 attended the requested follow-up appointment (37.2%). Mean patient age was 59.1 years, and the study population was 42.6% male and 57.4% female. The mean follow-up time for the prosthesis was 26 months. Abutment teeth had higher values in all periodontal variables (P removable partial dentures is affected by these rehabilitations. A recall program for these patients involving removable prosthodontics and periodontology appointments is mandatory.

  2. Police procedures in civil nuclear emergencies

    International Nuclear Information System (INIS)

    Smith, F.H.

    1989-01-01

    The responsibilities of the police in the event of a nuclear emergency are summarized. Preparation and planning is needed with site operators and other organisations who would also be involved in the event of an accident. Several points in particular are discussed; shelter and evacuation, the issue of potassium iodate tablets, protection of police officers, the police involvement in the operation support centres, public education and further discussion on the integration and development of the organisation of emergency procedures. (U.K.)

  3. Thermal-hydraulic processes involved in loss of residual heat removal during reduced inventory operation

    International Nuclear Information System (INIS)

    Fletcher, C.D.; McHugh, P.R.; Naff, S.A.; Johnsen, G.W.

    1991-02-01

    This paper identifies the topics needed to understand pressurized water reactor response to an extended loss of residual heat removal event during refueling and maintenance outages. By identifying the possible plant conditions and cooling methods that would be used for each cooling mode, the controlling thermal-hydraulic processes and phenomena were identified. Controlling processes and phenomena include: gravity drain, core water boil-off, and reflux cooling processes. Important subcategories of the reflux cooling processes include: the initiation of reflux cooling from various plant conditions, the effects of air on reflux cooling, core level depression effects, issues regarding the steam generator secondaries, and the special case of boiler-condenser cooling with once-through steam generators. 25 refs., 6 figs., 1 tab

  4. Selective sodium removal from lithium chloride brine with novel ...

    African Journals Online (AJOL)

    Natrium superionic conductor (NASICON) ceramics present interesting sensitive and selective properties against alkaline cations due to their structure. The powder of Li1.4La0.4Zr1.6(PO4)3 has been synthesized by a solid phase reaction. The removal of sodium was studied in an extensive series of tests involving different ...

  5. Surgeon-performed endoscopic retrograde cholangiopancreatography. Outcomes of 2392 procedures at two tertiary care centers.

    Science.gov (United States)

    Al-Mansour, Mazen R; Fung, Eleanor C; Jones, Edward L; Zayan, Nichole E; Wetzel, Timothy D; Martin Del Campo, Sara E; Jalilvand, Anahita D; Suzo, Andrew J; Dettorre, Rebecca R; Fullerton, James K; Meara, Michael P; Mellinger, John D; Narula, Vimal K; Hazey, Jeffrey W

    2018-06-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that, in the United States, is traditionally performed by gastroenterologists. We hypothesized that when performed by well-trained surgeons, ERCP can be performed safely and effectively. The objectives of the study were to assess the rate of successful cannulation of the duct of interest and to assess the 30-day complication and mortality rates. We retrospectively reviewed the charts of 1858 patients who underwent 2392 ERCP procedures performed by five surgeons between August 2003 and June 2016 in two centers. Demographic and historical data, indications, procedure-related data and 30-day complication and mortality data were collected and analyzed. The mean age was 53.4 (range 7-102) years and 1046 (56.3%) were female. 1430 (59.8%) of ERCP procedures involved a surgical endoscopy fellow. The most common indication was suspected or established uncomplicated common bile duct stones (n = 1470, 61.5%), followed by management of an existing biliary or pancreatic stent (n = 370, 15.5%) and acute biliary pancreatitis (n = 173, 7.2%). A therapeutic intervention was performed in 1564 (65.4%), a standard sphincterotomy in 1244 (52.0%), stent placement in 705 (29.5%) and stone removal in 638 (26.7%). When cannulation was attempted, the rate of successful cannulation was 94.1%. When cannulation was attempted during the patient's first ERCP the cannulation rate was 92.4%. 94 complications occurred (5.4%); the most common complication was post-ERCP pancreatitis in 75 (4.2%), significant gastrointestinal bleeding in 7 (0.4%), ascending cholangitis in 11 (0.6%) and perforation in 1 (0.05%). 11 mortalities occurred (0.5%) but none of which were ERCP-related. When performed by well-trained surgical endoscopists, ERCP is associated with high success rate and acceptable complication rates consistent with previously published reports and in line with societal guidelines.

  6. Eisenia fetida increased removal of polycyclic aromatic hydrocarbons from soil

    Energy Technology Data Exchange (ETDEWEB)

    Contreras-Ramos, Silvia M. [Laboratory of Soil Ecology, Department of Biotechnology and Bioengineering, Cinvestav, Av. Instituto Politecnico Nacional 2508, C.P. 07000 Mexico, D.F. (Mexico); Alvarez-Bernal, Dioselina [Laboratory of Soil Ecology, Department of Biotechnology and Bioengineering, Cinvestav, Av. Instituto Politecnico Nacional 2508, C.P. 07000 Mexico, D.F. (Mexico); Dendooven, Luc [Laboratory of Soil Ecology, Department of Biotechnology and Bioengineering, Cinvestav, Av. Instituto Politecnico Nacional 2508, C.P. 07000 Mexico, D.F. (Mexico)]. E-mail: dendoove@cinvestav.mx

    2006-06-15

    The removal of phenanthrene, anthracene and benzo(a)pyrene added at three different concentrations was investigated with or without earthworms (Eisenia fetida) within 11 weeks. Average anthracene removal by the autochthonous micro-organisms was 23%, 77% for phenanthrene and 13% for benzo(a)pyrene, while it was 51% for anthracene, 47% for benzo(a)pyrene and 100% for phenanthrene in soil with earthworms. At 50 and 100 mg phenanthrene kg{sup -1} E. fetida survival was 91% and 83%, but at 150 mg kg{sup -1} all died within 15 days. Survival of E. fetida in soil amended with anthracene {<=}1000 mg kg{sup -1} and benzo(a)pyrene {<=}150 mg kg{sup -1} was higher than 80% and without weight loss compared to the untreated soil. Only small amounts of PAHs were detected in the earthworms. It was concluded that E. fetida has the potential to remove large amounts of PAHs from soil, but more work is necessary to elucidate the mechanisms involved. - Addition of earthworms, Eisenia fetida, accelara removal of polycyclic aromatic hydrocarbons from soil.

  7. Eisenia fetida increased removal of polycyclic aromatic hydrocarbons from soil

    International Nuclear Information System (INIS)

    Contreras-Ramos, Silvia M.; Alvarez-Bernal, Dioselina; Dendooven, Luc

    2006-01-01

    The removal of phenanthrene, anthracene and benzo(a)pyrene added at three different concentrations was investigated with or without earthworms (Eisenia fetida) within 11 weeks. Average anthracene removal by the autochthonous micro-organisms was 23%, 77% for phenanthrene and 13% for benzo(a)pyrene, while it was 51% for anthracene, 47% for benzo(a)pyrene and 100% for phenanthrene in soil with earthworms. At 50 and 100 mg phenanthrene kg -1 E. fetida survival was 91% and 83%, but at 150 mg kg -1 all died within 15 days. Survival of E. fetida in soil amended with anthracene ≤1000 mg kg -1 and benzo(a)pyrene ≤150 mg kg -1 was higher than 80% and without weight loss compared to the untreated soil. Only small amounts of PAHs were detected in the earthworms. It was concluded that E. fetida has the potential to remove large amounts of PAHs from soil, but more work is necessary to elucidate the mechanisms involved. - Addition of earthworms, Eisenia fetida, accelara removal of polycyclic aromatic hydrocarbons from soil

  8. Removal of Shippingport Station primary system components and piping

    International Nuclear Information System (INIS)

    LaGuardia, T.S.; Lipsett, S.M.

    1987-01-01

    The dismantling workscope for the Shippingport Station Decommissioning Project was divided into subtasks to permit the work to be subcontracted to the maximum extent practicable. Major subtasks were identified and described by Activity specifications which could then be grouped into logical work packages to be put out for bid. Two of the largest dismantling work packages, removal of piping and components, were grouped together and designated as Activity Specifications 4 and 5. TLG Services, Inc. and Cleveland Wrecking Company formed a Joint Venture to perform this work during a two-year period at a cost of approximately $7 million. The major portions of this dismantling workscope are described. The primary system components within this workscope consist of the stainless steel reactor coolant piping, check valves, reactor coolant pumps, steam generators, and reactor purification demineralizers and coolers. The work performed, the heavy rigging preparations and procedures, the cutting tools used, component draining/capping techniques to prevent spills, contamination containment, airborne control techniques, and lessons learned during the removal of these primary system components are described. Summaries of crew size and composition, labor hours, duration hours and radiation exposure to workers are provided and discussed briefly. The successful completion of this work is evidence of the engineering, planning, equipment, materials and labor pool available to remove large, radioactively contaminated components safely. This experience will help decommissioning planners to prepare for the removal of reactor components in future decommissioning

  9. Reliability of electrode wear compensation based on material removal per discharge in micro EDM milling

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Tristo, G.; Hansen, Hans Nørgaard

    2013-01-01

    This paper investigates the reliability of workpiece material removal per discharge (MRD) estimation for application in electrode wear compensation based on workpiece material removal. An experimental investigation involving discharge counting and automatic on the machine measurement of removed...... material volume was carried out in a range of process parameters settings from fine finishing to roughing. MRD showed a decreasing trend with the progress of the machining operation, reaching stabilization after a number of machined layers. Using the information on MRD and discharge counting, a material...

  10. A modified-simple technique of removing the lens cortex during cataract surgery

    Directory of Open Access Journals (Sweden)

    Kyung Eun Han

    2017-01-01

    Full Text Available We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD, and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.

  11. Radiation control standards and procedures

    Energy Technology Data Exchange (ETDEWEB)

    1956-12-14

    This manual contains the Radiation Control Standards'' and Radiation Control Procedures'' at Hanford Operations which have been established to provide the necessary control radiation exposures within Irradiation Processing Department. Provision is also made for including, in the form of Bulletins'', other radiological information of general interest to IPD personnel. The purpose of the standards is to establish firm radiological limits within which the Irradiation Processing Department will operate, and to outline our radiation control program in sufficient detail to insure uniform and consistent application throughout all IPD facilities. Radiation Control Procedures are intended to prescribe the best method of accomplishing an objective within the limitations of the Radiation Control Standards. A procedure may be changed at any time provided the suggested changes is generally agreeable to management involved, and is consistent with department policies and the Radiation Control Standards.

  12. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    Science.gov (United States)

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. The characteristics and mechanisms of Au nanoparticles processed by functional centrifugal procedures

    Science.gov (United States)

    Shiau, Bo-Wen; Lin, Chien-Hung; Liao, Ying-Yen; Lee, Ya-Rong; Liu, Shih-Hao; Ding, Wei-Cheng; Lee, Jia-Ren

    2018-05-01

    In this work, the optical properties of Au nanoparticles processed by centrifugation techniques are studied. Most of the literature related to the control of nanoparticle size has focused on different preparation parameters; however, the wide size distribution is commonly an issue for follow-up investigations and further applications. Therefore, we developed a method in which specific-diameter particles can be effectively separated using different centrifugal procedures. The initial nanoparticle solution with a primary absorption peak at 534 nm is separated into discernible resonance wavelengths from 526 to 537 nm, with corresponding particle sizes from 30 to 55 nm. For the atomic force microscopy analysis of nanoparticle size, a dry cetyltrimethylammonium bromide (CTAB) film often covers the particles and interferes with the measurement; thus, CTAB has to be removed. However, if too much CTAB is removed, the surface of the Au nanoparticle becomes unstable, and the particles aggregate. Accordingly, we used UV spectroscopy to monitor the CTAB content; properly adjust the rotational speed and the number of centrifugation stages; and design a method that can effectively remove impurities, avoid clustering, and enable particle size measurement. The usually complicated procedures and high cost of preparation of specific-size Au nanoparticles are greatly simplified and reduced by the convenient extraction process proposed in this work, which would benefit related research and applications.

  14. Endoscopically guided removal of cloacal calculi in three African spurred tortoises (Geochelone sulcata).

    Science.gov (United States)

    Mans, Christoph; Sladky, Kurt K

    2012-04-01

    3 female African spurred tortoises (Geochelone sulcata) of various body weights (0.22, 0.77, and 2.86 kg [0.48, 1.69, and 6.29 lb]) were examined because of reduced food intake and lack of fecal output. Owners reported intermittent tenesmus in 2 of the tortoises. Physical examinations revealed no clinically important abnormalities in the tortoises. Cloacal calculi were diagnosed on the basis of radiography and cloacoscopy in all 3 tortoises. One tortoise had another calculus in the urinary bladder. Tortoises were anesthetized, and cloacal calculi were removed by use of a cutting burr (plain-fissure cutting burr and a soft tissue protector mounted to a dental handpiece that had a low-speed motor and a straight nose cone) and warm water irrigation with endoscopic guidance. Complete removal of calculus fragments was achieved by use of forceps and irrigation. In 1 tortoise, removal of the cloacal calculus was staged (2 separate procedures). In another tortoise, a second cloacal calculus (which had been located in the urinary bladder during the first examination) was successfully removed 25 days after removal of the first calculus. All 3 tortoises recovered uneventfully, and serious complications secondary to removal of the cloacal calculi were not detected. Cloacoscopy combined with the use of a low-speed dental drill and warm water irrigation should be considered a simple, safe, and nontraumatic treatment option for removal of obstructive cloacal calculi in tortoises.

  15. Impact of nonnative feral pig removal on soil structure and nutrient availability in Hawaiian tropical montane wet forests

    Science.gov (United States)

    Michael S. Long; Creighton M. Litton; Christian P. Giardina; Jonathan Deenik; Rebecca J. Cole; Jed P. Sparks

    2017-01-01

    Conservation and restoration of ecosystems impacted by nonnative ungulates increasingly involves their removal and exclusion. While the influence of nonnative ungulate removal on plant communities is commonly monitored, impacts on underlying ecological processes are seldom quantified. Here we examined how nonnative feral pig (

  16. Optimizing winter/snow removal operations in MoDOT St. Louis district : includes outcome based evaluation of operations.

    Science.gov (United States)

    2011-10-01

    The objective of this project was to develop fleet location, route decision, material selection, and treatment procedures for winter snow removal operations to improve MoDOTs services and lower costs. This work uses a systematic, heuristic-based o...

  17. Photodynamic therapy for hair removal

    Directory of Open Access Journals (Sweden)

    Mohamed H. M. Ali

    2013-05-01

    in selectively damaging hair follicles, leaving an intact epidermis. The current PDT system provides better outcome than hair destruction through laser heat transfer procedures and laser-mediated hair removal, due to complete destruction of hair follicles.

  18. Reactors also involve people

    International Nuclear Information System (INIS)

    Hurt, H.B.

    1975-01-01

    As the nuclear industry develops it is to be hoped that high quality occupational health programs will evolve along with other sound operational procedures and practices. The immediate involvement of occupational health personnel may well afford a safety factor which will minimize the likelihood of either the selection of personnel not adequate for the full responsibilities of their work or the continuation in responsible positions of personnel who develop handicaps of either a physical or mental nature

  19. Comparison of rigid and flexible endoscopy for removing esophageal foreign bodies in an emergency

    Directory of Open Access Journals (Sweden)

    Chia-Chen Tseng

    2016-08-01

    Conclusion: Both FE and RE remove esophageal FBs successfully, as evidenced by their high success rates, low complication rates, and high detection rates. Although FE under local anesthesia is a less time-consuming procedure for adults, RE under general anesthesia may be preferable for children and can serve as an alternative to FE.

  20. Procedures for high precision setup verification and correction of lung cancer patients using CT-simulation and digitally reconstructed radiographs (DRR).

    NARCIS (Netherlands)

    Sornsen de Koste, van J.R.; Boer, de HC; Schuchhard-Schipper, RH; Senan, S.; Heijmen, BJ

    2003-01-01

    PURPOSE: In a recent study, large systematic setup errors were detected in patients with lung cancer when a conventional simulation procedure was used to define and mark the treatment isocenter. In the present study, we describe a procedure to omit the session at a conventional simulator to remove

  1. Removal of endotoxins from bacteriophage preparations by extraction with organic solvents.

    Directory of Open Access Journals (Sweden)

    Bożena Szermer-Olearnik

    Full Text Available Lipopolysaccharide (LPS, endotoxin, pyrogen constitutes a very troubling contaminant of crude phage lysates produced in Gram-negative bacteria. Toxicity of LPS depends on the strong innate immunity response including the cytokines. Therefore, its removal is important for bacteriophage applications. In this paper, we present a procedure for extractive removal of endotoxin from bacteriophage preparations with water immiscible solvents (1-octanol or 1-butanol. During extraction most of the phage lytic activity is retained in the aqueous phase, while endotoxin accumulates in the organic solvent. The levels of endotoxin (expressed as endotoxin units, EU in the aqueous bacteriophage-containing fraction determined by limulus amebocyte lysate or EndoLISA assay were exceptionally low. While the initial endotoxin levels in the crude phage lysates ranged between 10(3 and 10(5 EU/ml the average level after organic extraction remaining in the aqueous fraction was 5.3 EU/ml. These values when related to phage titers decreased from 10(3-10(5 EU/10(9 PFU (plaque forming units down to an average of 2.8 EU/10(9 PFU. The purification procedure is scalable, efficient and applicable to all the bacteriophages tested: T4, HAP1 (E. coli and F8 (P. aeruginosa.

  2. Procedure for reducing hydrogen ion concentration in acidic anion eluate

    International Nuclear Information System (INIS)

    Parobek, P.; Baloun, S.; Plevac, S.

    1992-01-01

    A procedure is suggested for reducing the concentration of hydrogen ions in the acidic anionic eluate formed during the separation of uranium. The procedure involves anex elution, precipitation, filtration, precipitate rinsing, and anex rinsing. The procedure is included in the uranium elution process and requires at least one ion exchanger column and at least one tank in the continuous or discontinuous mode. Sparing the neutralizing agent by reducing the hydrogen ion concentration in the acidic anionic eluate is a major asset of this procedure. (Z.S.). 1 fig

  3. EFFICACY OF DIFFERENT ENDODONTIC IRRIGATION PROTOCOLS IN CALCIUM HYDROXIDE REMOVAL

    Directory of Open Access Journals (Sweden)

    Elka N. Radeva

    2016-10-01

    Full Text Available Introduction: Calcium hydroxide is widely used in the field of endodontics as a temporary root canal filling. This medicament significantly increases pH and optimizes the treatment outcome. Its total removal before final obturation is very important. Otherwise it could affect the hermetic filling and respectively the endodontic success. Aim: To evaluate the most effective irrigation protocol of calcium hydroxide removal from root canals. Materials and methods: In this study 36 single root canal teeth were observed. They were randomly divided into three groups (n=10 each group according to the technique applied for calcium hydroxide removal - manual irrigation, irrigation and Revo-S rotary instrumentation; and passive ultrasonic irrigation, and a control group (n=6 – irrigation with distilled water only. After calcium hydroxide removals following the procedures above, teeth were separated longitudinally in a buccal-lingual direction and remnants of medicaments were observed in the apical, middle and coronal part of each tooth. Then all of the specimens were observed using scanning electron microscopy and evaluated by a specified scale. The results have undergone statistical analysis. Results: In the case of calcium hydroxide in the apex and in the middle with highest average is Revo-S, followed by Ultrasonic and irrigation. In the coronal part the highest average belongs to Revo-S, irrigation and Ultrasonic. In all groups the highest average is represented by control group. Conclusion: There is not a universal technique for removal of intracanal medicaments and applying more than one protocol is required.

  4. Application of Mineral Sorbents for Removal of Petroleum Substances: A Review

    Directory of Open Access Journals (Sweden)

    Lidia Bandura

    2017-03-01

    Full Text Available Environmental pollution with petroleum products has become a major problem worldwide, and is a consequence of industrial growth. The development of sustainable methods for the removal of petroleum substances and their derivatives from aquatic and terrestrial environments and from air has therefore become extremely important today. Advanced technologies and materials dedicated to this purpose are relatively expensive; sorption methods involving mineral sorbents are therefore popular and are widely described in the scientific literature. Mineral materials are easily available, low-cost, universal adsorbents and have a number of properties that make them suitable for the removal of petroleum substances. This review describes recent works on the use of natural, synthetic and modified mineral adsorbents for the removal of petroleum substances and their derivatives from roads, water and air.

  5. Complications of aesthetic medicine procedures: five case studies.

    Science.gov (United States)

    Smędra, A; Szustowski, S; Klemm, J; Jurczyk, A; Zalewska-Janowska, A; Berent, J

    2015-01-01

    The paper presents the cases of five patients who developed complications after aesthetic medicine procedures. Four of the cases involved women who reported to the Department of Forensic Medicine, Medical University of Lodz, for a description and legal qualification of bodily injuries suffered as a result of aesthetic medicine procedures, whereas one was related to the assessment of accuracy of medical management at the request of the prosecutor handling the case. The reported cases concerned acid exfoliation treatments, photoepilation and cryotherapy. The authors attempt to discuss the most common complications that may occur after aesthetic medicine procedures, and measures to avoid them.

  6. Ethics of fertility preservation for prepubertal children: should clinicians offer procedures where efficacy is largely unproven?

    Science.gov (United States)

    McDougall, Rosalind J; Gillam, Lynn; Delany, Clare; Jayasinghe, Yasmin

    2018-01-01

    Young children with cancer are treated with interventions that can have a high risk of compromising their reproductive potential. 'Fertility preservation' for children who have not yet reached puberty involves surgically removing and cryopreserving reproductive tissue prior to treatment in the expectation that strategies for the use of this tissue will be developed in the future. Fertility preservation for prepubertal children is ethically complex because the techniques largely lack proven efficacy for this age group. There is professional difference of opinion about whether it is ethical to offer such 'experimental' procedures. The question addressed in this paper is: when, if ever, is it ethically justifiable to offer fertility preservation surgery to prepubertal children? We present the ethical concerns about prepubertal fertility preservation, drawing both on existing literature and our experience discussing this issue with clinicians in clinical ethics case consultations. We argue that offering the procedure is ethically justifiable in certain circumstances. For many children, the balance of benefits and burdens is such that the procedure is ethically permissible but not ethically required; when the procedure is medically safe, it is the parents' decision to make, with appropriate information and guidance from the treating clinicians. We suggest that clinical ethics support processes are necessary to assist clinicians to engage with the ethical complexity of prepubertal fertility preservation and describe the framework that has been integrated into the pathway of care for patients and families attending the Royal Children's Hospital in Melbourne, Australia. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. 77 FR 31443 - Energy Conservation Program: Test Procedures for Residential Dishwashers, Dehumidifiers, and...

    Science.gov (United States)

    2012-05-25

    ... an ion exchange to remove calcium and magnesium ions from the water, by swapping sodium ions bonded... addresses energy and water use associated with dishwasher water softeners, the energy test cycle for... dehumidifier test procedure, eliminate measurement of gas pilot light energy use in the cooking products test...

  8. Radioactive liquid wastes lines removal project at Los Alamos (1981-1986)

    International Nuclear Information System (INIS)

    Elder, J.C.; Cox, E.J.; Hohner, D.P.; Valentine, A.M.

    1986-09-01

    This report describes the abandoned liquid waste lines removal operations conducted at Los Alamos in the period 1981 to 1986. Particular emphasis has been placed on as-left conditions, that is, on the location of sections of waste lines or contaminated soil which were left in place on the basis of ALARA decisions. Contaminated items were left when interfering utilities, roads, structures, or great depth made complete removal not cost effective or not safe. Left items were either not highly contaminated or they were not near the surface. Total cost of the project was $4.2 million. Approximately 5800 m 3 of contaminated waste was placed in the Solid Waste Management Site at TA-54 Area G. The project accomplished the removal of approximately 34,500 ft (6.5 miles) of abandoned waste lines under carefully controlled conditions. Procedures for excavation, waste disposal, personnel protection, and radiation monitoring are described. Environmental monitoring criteria and methods for determining acceptable levels of contamination in soils and on surfaces are discussed

  9. Experimental Analysis and Process Modeling of Carbon Dioxide Removal Using Tuff

    Directory of Open Access Journals (Sweden)

    Emanuele Bonamente

    2016-12-01

    Full Text Available Removal of carbon dioxide via selective adsorption is a key process to obtain consumer-grade natural gas from biogas and, more generally, CO2 capture and sequestration from gaseous mixtures. The aim of this work is the characterization and classification of a natural alternative to synthetic zeolites that could be used as a carbon dioxide adsorbent. Tuff particulate, easily available as a byproduct of the construction industry, was tested with different laboratory procedures to verify its suitability for CO2 removal applications. Relevant physical and adsorption properties were measured during an intensive experimental campaign. Porosity, pore size distribution, and specific surface area were obtained with mercury intrusion porosimetry. Adsorption isotherms and saturation curves were obtained using two custom experimental apparatuses. The selective adsorption was finally modeled using an original phenomenological parameterization, and a simplified simulation of the process was performed using a computational fluid dynamic approach, validated against observed data. Results show that natural zeolites represent a very promising and sustainable alternative to synthetic zeolites in pressure swing adsorption processes for CO2 removal.

  10. Evaluation of Surface Cleaning Procedures for CTGS Substrates for SAW Technology with XPS

    Directory of Open Access Journals (Sweden)

    Erik Brachmann

    2017-11-01

    Full Text Available A highly efficient and reproducible cleaning procedure of piezoelectric substrates is essential in surface acoustic waves (SAW technology to fabricate high-quality SAW devices, especially for new applications such SAW sensors wherein new materials for piezoelectric substrates and interdigital transducers are used. Therefore, the development and critical evaluation of cleaning procedures for each material system that is under consideration becomes crucial. Contaminants like particles or the presence of organic/inorganic material on the substrate can dramatically influence and alter the properties of the thin film substrate composite, such as wettability, film adhesion, film texture, and so on. In this article, focus is given to different cleaning processes like SC-1 and SC-2, UV-ozone treatment, as well as cleaning by first-contact polymer Opticlean, which are applied for removal of contaminants from the piezoelectric substrate Ca 3 TaGa 3 Si 2 O 14 . By means of X-ray photoelectron spectroscopy, the presence of the most critical contaminants such as carbon, sodium, and iron removed through different cleaning procedures were studied and significant differences were observed between the outcomes of these procedures. Based on these results, a two-step cleaning process, combining SC-1 at a reduced temperature at 30 ∘ C instead of 80 ∘ C and a subsequent UV-ozone cleaning directly prior to deposition of the metallization, is suggested to achieve the lowest residual contamination level.

  11. Modified nuss procedure in concurrent repair of pectus excavatum and open heart surgery.

    Science.gov (United States)

    Sacco Casamassima, Maria Grazia; Wong, Ling Ling; Papandria, Dominic; Abdullah, Fizan; Vricella, Luca A; Cameron, Duke E; Colombani, Paul M

    2013-03-01

    Pectus excavatum (PE) can be associated with congenital and acquired cardiac disorders that also require surgical repair. The timing and specific surgical technique for repair of PE remains controversial. The present study reports the experience of combined repair of PE and open heart surgery at Johns Hopkins Hospital. A retrospective case review was conducted of all patients who presented for repair of PE deformity while undergoing concurrent open heart surgery from 1998 through 2011. A total of 9 patients met inclusion criteria. All patients had a connective tissue disorder. Repair of PE was performed by modified Nuss technique after completion of the cardiac procedure, performed through a median sternotomy. Open heart procedures were either aortic root replacement or mitral valvuloplasty. Eight patients had bar removal after an average period of 30.3 months. No PE recurrence, bar displacement, or upper sternal depression was reported in 7 patients. Postoperatively, 1 patient exhibited pectus carinatum after a separate spinal fusion surgery for scoliosis. One patient died of unrelated cardiac complications before bar removal. Simultaneous repair of PE and open heart surgery is safe and effective. We recommend that the decision to perform a single-stage versus a multistage procedure should be reserved until after the cardiac procedure has been completed. In such cases, the Nuss technique allows for correction of the pectus deformity with good long-term cosmetic and functional results. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Efficient removal of sulfur hexafluoride (SF6) through reacting with recycled electroplating sludge.

    Science.gov (United States)

    Zhang, Jia; Zhou, Ji Zhi; Liu, Qiang; Qian, Guangren; Xu, Zhi Ping

    2013-06-18

    This paper reports that recycled electroplating sludge is able to efficiently remove greenhouse gas sulfur hexafluoride (SF6). The removal process involves various reactions of SF6 with the recycled sludge. Remarkably, the sludge completely removed SF6 at a capacity of 1.10 mmol/g (SF6/sludge) at 600 °C. More importantly, the evolved gases were SO2, SiF4, and a limited amount of HF, with no toxic SOF4, SO2F2, or SF4 being detected. These generated gases can be readily captured and removed by NaOH solution. The reacted solids were further found to be various metal fluorides, thus revealing that SF6 removal takes place by reacting with various metal oxides and silicate in the sludge. Moreover, the kinetic investigation revealed that the SF6 reaction with the sludge is a first-order chemically controlled process. This research thus demonstrates that the waste electroplating sludge can be potentially used as an effective removal agent for one of the notorious greenhouse gases, SF6.

  13. Removing Hair Safely

    Science.gov (United States)

    ... For Consumers Home For Consumers Consumer Updates Removing Hair Safely Share Tweet Linkedin Pin it More sharing ... related to common methods of hair removal. Laser Hair Removal In this method, a laser destroys hair ...

  14. Sodium removal from Hallam Reactor components

    International Nuclear Information System (INIS)

    Huntsman, L.K.; Meservey, R.H.

    1979-08-01

    This report discussed the removal of sodium from major components of the Hallam Nuclear Power Facility. This facility contained the experimental ractor used to test the feasibility of sodium coolant. The Idaho Operations Office of the Department of Energy assigned EG and G Idaho, Inc., the task of carrying out this decontamination and decommissioning program at the Idaho National Engineering Laboratory (INEL). Since their shipment to the INEL from Lincoln, Nebraska in 1968, the Hallam Reactor components had been stored in inert nitrogen to prevent the sodium in the components from reacting with moisture in the air. The procedure used to react the sodium in the components and to decontaminate them is discussed. Problems and unusual occurrences in the decontamination and decommissioning process are also reported

  15. Accumulation of nuclear fission products by vegetable crops and their removal during processing

    International Nuclear Information System (INIS)

    Weaver, C.M.

    1978-01-01

    The accumulation and turn over of 90 Sr and 137 Cs throughout the growth cycle of a vegetable crop was studied as well as the removal of these radionuclides in several vegetables by washing, blanching, freezing, canning, and pickling procedures. The results indicated that radiocontamination of vegetable crops with 137 Cs would result in greatest internal concentrations if exposure occurred early in the growth cycle of the plant, whereas, the greatest contamination by 90 Sr would occur from exposure during the middle of the growing period. Pulse labelling experiments were employed to examine turn over of radionuclides in kale. No net efflux of radionuclides from plants following exposure to either radionuclide was observed. Of the processing treatments employed on several types of vegetables, a combination of pickling and canning of cucumbers resulted in the greatest decontamination - 94% for 137 Cs and 65% for 90 Sr. Canning was highly effective in reducing radionuclide concentrations in beans and kale. However, freezing significantly reduced the radionuclide content of only 137 Cs in kale. Preparatory procedures prior to processing did not significantly reduce radionuclide levels except for 137 Cs in beans. The combination of washing, blanching, and canning sweet potatoes exposed to radionuclides resulted in the removal of 1.4% 137 Cs and 26.5% 90 Sr relative to unprocessed controls. The blanching process resulted in a transfer of radioactivity from the peel to the core, indicating that skins of contaminated potatoes should be removed prior to thermal treatment

  16. 40 CFR 26.1110 - Expedited review procedures for certain kinds of research involving no more than minimal risk...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Expedited review procedures for certain....1110 Section 26.1110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GENERAL PROTECTION OF... Intentional Exposure of Non-pregnant, Non-nursing Adults § 26.1110 Expedited review procedures for certain...

  17. Cocaine versus food choice procedure in rats: environmental manipulations and effects of amphetamine.

    Science.gov (United States)

    Thomsen, Morgane; Barrett, Andrew C; Negus, S Stevens; Caine, S Barak

    2013-03-01

    We have adapted a nonhuman primate model of cocaine versus food choice to the rat species. To evaluate the procedure, we tested cocaine versus food choice under a variety of environmental manipulations as well as pharmacological pretreatments. Complete cocaine-choice dose-effect curves (0-1.0 mg/kg/infusion) were obtained for each condition under concurrent fixed ratio schedules of reinforcement. Percentage of responding emitted on the cocaine-reinforced lever was not affected significantly by removal of cocaine-associated visual or auditory cues, but it was decreased after removal of response-contingent or response-independent cocaine infusions. Cocaine choice was sensitive to the magnitude and fixed ratio requirement of both the cocaine and food reinforcers. We also tested the effects of acute (0.32, 0.56, 1.0, 1.8 mg/kg) and chronic (0.1, 0.32 mg/kg/hr) d-amphetamine treatment on cocaine choice. Acute and chronic d-amphetamine had opposite effects, with acute increasing and chronic decreasing cocaine choice, similar to observations in humans and in nonhuman primates. The results suggest feasibility and utility of the choice procedure in rats and support its comparability to similar procedures used in humans and monkeys. © Society for the Experimental Analysis of Behavior.

  18. Standardisation of heavy vehicle crash investigation procedures in South Africa

    CSIR Research Space (South Africa)

    Dube, S

    2015-07-01

    Full Text Available regarding accidents involving heavy vehicles and even less is known about the real cause of these accidents. This paper reports on the findings of a study on the status of heavy vehicle accident investigation procedures in South Africa. This study involved a...

  19. Sulphur removal from used automotive lubricating oil by ionizing radiation

    International Nuclear Information System (INIS)

    Scapin, Marcos Antonio; Duarte, Celina Lopes; Sato, Ivone Mulako

    2007-01-01

    Following the worldwide evolution with the purpose of a higher control of vehicular emissions, the specialists have looked for clean technologies and efficient procedures to make vehicular emissions free of pollutants. Much attention is given to the sulphur concentration in the gasoline, diesel and lubricating oils. The ionizing radiation is a promising technology for the removal of this pollutant when compared to other conventional treatment methods. In this work, the ionizing radiation was used to remove in significant levels the presence of sulphur in automotive motor oil. A 1000 mL sample of used automotive lubricating oil from a gas station was collected. This sample was fractioned and irradiated with 10, 20 50, 100, 200 and 500 kGy doses in a 60 Co irradiator (GAMMACELL-220 - 12 kCi). The 50 and 70% (v/v) of MilliQ water and 30% (v/v) of hydrogen peroxide was used to improve the radiolysis The sulphur element before and after the irradiation was determined by X-ray fluorescence technique (WDXRF) using the Fundamental Parameters Method. The results showed approximately 70% sulphur removal at 500 kGy irradiation dose with 70% (v/v) of MilliQ water addition. (author)

  20. The influence of milking procedures on cow’s teat tissue, milk yield and milking time

    Directory of Open Access Journals (Sweden)

    Saša Špoljar

    2004-04-01

    Full Text Available The aim of this study was to evaluate the effect of two different milking procedures on teat length and diameter, milk yield and milking time. During the first milking procedure the milker decides when to remove the milking cluster from the udder, while in the second an automatic cluster removal, when milk flow was lower than 200 g/min, was performed. Measurements were made on two commercial farms B and A on 15 randomly chosen cows without any clinical sign of mastitis. There were no significant differencesbetween those farms in teat length and diameter differences before and after the milking. Average milking time on farm A was 6 min and 58 s, while on farm B was 5 min and 3 s. Average milk yield was 12.9 kg on farm B and 13.4 kg on farm A. Milking time was considerably shorter on farm B compared to farm A, while milk yield was almost equal on both farms. Automatic cluster weighting 2 kg removal was performed when milk flow was lower than 200 g/min in order to shorten the time needed to milk the cow, ensuring good udder health.

  1. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  2. Health and Safety Procedures Manual for hazardous waste sites

    Energy Technology Data Exchange (ETDEWEB)

    Thate, J.E.

    1992-09-01

    The Oak Ridge National Laboratory Chemical Assessments Team (ORNL/CAT) has developed this Health and Safety Procedures Manual for the guidance, instruction, and protection of ORNL/CAT personnel expected to be involved in hazardous waste site assessments and remedial actions. This manual addresses general and site-specific concerns for protecting personnel, the general public, and the environment from any possible hazardous exposures. The components of this manual include: medical surveillance, guidance for determination and monitoring of hazards, personnel and training requirements, protective clothing and equipment requirements, procedures for controlling work functions, procedures for handling emergency response situations, decontamination procedures for personnel and equipment, associated legal requirements, and safe drilling practices.

  3. MITS Feed and Withdrawal Subsystem: operating procedures

    International Nuclear Information System (INIS)

    Brown, W.S.

    1980-01-01

    This procedure details the steps involved in filling two of the four MITS (Machine Interface Test System) Feed and Withdrawal subsystem main traps and the Sample/Inventory Make-up Pipette with uranium hexafluoride from the ''AS RECEIVED'' UF 6 supply

  4. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    International Nuclear Information System (INIS)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days

  5. Evaluation of some procedures relevant to the determination of trace elemental components in biological materials by destructive neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Berry, D.L.

    1979-01-01

    The development of a simplified procedure for the analysis of biological materials by destructive neutron activation analysis (DNAA) is described. The sample manipulations preceding gamma ray assay were investigated as five specific stages of processing: (1) pre-irradiation treatment; (2) sample irradiation; (3) removal of the organic matrix; (4) removal of interfering radioactivities; and (5) concentration and separation of analyte activities. Each stage was evaluated with respect to susceptibility to sample contamination, loss of trace elemental components, and compatibility with other operations in the overall DNAA procedures. A complete DNAA procedure was proposed and evaluated for the analysis of standard bovine liver and blood samples. The DNAA system was effective for the determination of As, Cu, Fe, Hg, Mo, Rb, Sb, Se, and Zn without yield determinations and with a minimum turn-around time of approximately 3 days.

  6. Approaches to child protection case management for cases involving people with disabilities.

    Science.gov (United States)

    Lightfoot, Elizabeth B; LaLiberte, Traci L

    2006-04-01

    This exploratory study examines the delivery of child protection services by county child protection agencies involving cases with a family member with a disability. Telephone surveys were conducted with the directors or their designees of 89% of the child protection agencies in a Midwestern state. Respondents were asked about the policies and/or procedures for approaching cases involving a person with a disability and the barriers and strengths agencies have in serving people with disabilities. Only 6.7% of respondents reported their agency had a written policy related to serving persons with a disability. There were 18 different approaches to serving clients with a disability within child protection, with the most common being informally teaming for information, dual case assignment, and teaming with an outside consultant. Five counties had specialty workers who were experts in both child protection and disability. Barriers reported varied between rural and non-rural counties, with the most important barriers being lack of resources, lack of knowledge regarding disabilities, systems conflicts, and rural issues, such as lack of providers and lack of transportation. Strengths included accessing and coordinating services, individualizing services, good collaboration and creativity. While few county agencies had any written policies, both formal and informal collaboration is happening at the individual level. The lack of standardization in providing services indicates a need for more attention to issues regarding disability within child protection, including more training for workers, the development of models of collaborative case management and the removal of systemic barriers.

  7. A flexible endoscope-assisted interhemispheric transcallosal approach through the contralateral ventricle for the removal of a third ventricle craniopharyngioma: A technical report.

    Science.gov (United States)

    Yano, Shigetoshi; Hide, Takuichiro; Shinojima, Naoki; Ueda, Yutaka; Kuratsu, Jun-Ichi

    2015-01-01

    Intraventricular craniopharyngiomas are difficult to remove. We combined an interhemispheric transcallosal approach with a flexible endoscope (videoscope) for successful tumor removal. A 52-year-old male complained of general fatigue and memory disturbance. Magnetic resonance imaging revealed a well-enhanced third ventricle mass with dilatation of lateral ventricles. During removal with the interhemispheric transcallosal approach, a videoscope that was inserted into the left lateral ventricle revealed the interface of the tumor and the ventricular wall. The tumor was pushed to the right using forceps and removed totally through the right foramen of Monro without any fornix injury. This procedure is a safe option for removing third ventricular tumors especially in the case with hydrocephalus.

  8. Quality assurance and gastrointestinal endoscopy: an audit of 500 colonoscopic procedures.

    Science.gov (United States)

    Denis, Bernard; Weiss, Anne-Marie; Peter, André; Bottlaender, Jacques; Chiappa, Pascale

    2004-12-01

    The aim of this study was to assess the quality of colonoscopic procedures in our endoscopy unit with the goal of improving performance. We prospectively audited 500 consecutive colonoscopic procedures and assessed sixty-two process or outcome indicators for each procedure. Most of the measured indicators were within standard limits: cecal intubation rate (92%), inadequate bowel preparations (24%), inappropriate procedures (9.7%), normal procedures (54%), yield for neoplasia (32%), morbidity (0.4%), and overall patient satisfaction (95.8%). Some indicators were outside standard limits suggesting our practices should be modified: endoscopy withdrawal time less than 6 minutes (78%), forceps removal of polyps (31%), resected polyps not recovered for pathological examination (12%), adenomas with villous elements (22%), patients unsatisfied because of time spent waiting for the procedure (19%), patients unsatisfied because of inadequate explanations (10%). There was no standard for a few indicators: patient discomfort (6.9%), diagnostic success (89%), therapeutic success (92%). Three new indicators were proposed: proportion of patients agedadvanced adenoma or cancer, and proportion of colonoscopic procedures causing discomfort. The diagnostic yield of colonoscopy was dependent on age, gender, indication and appropriateness of indication but not on the prescriber. This audit allowed us to evaluate our endoscopic practices and to detect certain shortcomings and deviations from standards. It enabled us to change some of our practices with the goal of improving the quality of our colonoscopic procedures.

  9. Study on thermal-hydraulic phenomena identification of passive heat removal facilities

    International Nuclear Information System (INIS)

    Park, J. Y.

    2011-01-01

    Recently, passive heat removal facilities have been integral features of new generation or future reactor designs worldwide. This is because the passive heat removal facilities depending on a natural force such as buoyancy can give much higher operational reliability compared to active heat removal facilities depending on pumped fluid flow and as a result they can decrease core damage frequency of a nuclear power plant drastically ever achievable before. Keeping pace with this global trend, SMART and APR+ reactors also have introduced passive heat removal features such as a passive residual heat removal system (PRHRS) and a passive auxiliary feed water system (PAFS) in their designs. Since many thermal-hydraulic (T-H) phenomena including steam condensation are involved during operation of the passive heat removal facilities, they ought to be properly simulated by T-H codes such as MARS-KS and RELAP5 in order to guarantee reliable safety analysis by these codes. Unfortunately, however, these T-H codes are not well validated with respect to phenomena related to passive heat removal mechanism because previous focus on these codes validation was mainly on the LB LOCA and resulting phenomena. To resolve this gap, Korea Institute of Nuclear Safety has initiated a research program on the development of safety analysis technology for passive heat removal facilities. The main target of this program is PRHRS and PAFS in SMART and APR+ reactors and through this program, validation of capability of existing T-H codes and improvement of codes regarding passive facilities analysis are to be sought. In part of this research, T-H phenomena important to passive heat removal facilities (PRHRS and PAFS) are investigated in the present study

  10. Grinding model and material removal mechanism of medical nanometer zirconia ceramics.

    Science.gov (United States)

    Zhang, Dongkun; Li, Changhe; Jia, Dongzhou; Wang, Sheng; Li, Runze; Qi, Xiaoxiao

    2014-01-01

    Many patents have been devoted to developing medical nanometer zirconia ceramic grinding techniques that can significantly improve both workpiece surface integrity and grinding quality. Among these patents is a process for preparing ceramic dental implants with a surface for improving osseo-integration by sand abrasive finishing under a jet pressure of 1.5 bar to 8.0 bar and with a grain size of 30 µm to 250 µm. Compared with other materials, nano-zirconia ceramics exhibit unmatched biomedical performance and excellent mechanical properties as medical bone tissue and dentures. The removal mechanism of nano-zirconia materials includes brittle fracture and plastic removal. Brittle fracture involves crack formation, extension, peeling, and chipping to completely remove debris. Plastic removal is similar to chip formation in metal grinding, including rubbing, ploughing, and the formation of grinding debris. The materials are removed in shearing and chipping. During brittle fracture, the grinding-led transverse and radial extension of cracks further generate local peeling of blocks of the material. In material peeling and removal, the mechanical strength and surface quality of the workpiece are also greatly reduced because of crack extension. When grinding occurs in the plastic region, plastic removal is performed, and surface grinding does not generate grinding fissures and surface fracture, producing clinically satisfactory grinding quality. With certain grinding conditions, medical nanometer zirconia ceramics can be removed through plastic flow in ductile regime. In this study, we analyzed the critical conditions for the transfer of brittle and plastic removal in nano-zirconia ceramic grinding as well as the high-quality surface grinding of medical nanometer zirconia ceramics by ELID grinding.

  11. BOA: Pipe-asbestos insulation removal robot system

    International Nuclear Information System (INIS)

    Schempf, H.; Bares, J.; Mutschler, E.

    1995-01-01

    This paper describes the BOA system, a mobile pipe-external crawler used to remotely strip and bag (possibly contaminated) asbestos-containing lagging and insulation materials (ACLIM) from various diameter pipes in (primarily) industrial installations across the DOE weapons complex. The mechanical removal of ACLIM is very cost-effective due to the relatively low productivity and high cost involved in human removal scenarios. BOA, a mechanical system capable of removing most forms of lagging (paper, plaster, aluminum sheet, clamps, screws and chicken-wire), and insulation (paper, tar, asbestos fiber, mag-block) uses a circular cutter and compression paddles to cut and strip the insulation off the pipe through compression, while a HEPA-filter and encapsulant system maintain a certifiable vacuum and moisture content inside the system and on the pipe, respectively. The crawler system has been built and is currently undergoing testing. Key design parameters and performance parameters are developed and used in performance testing. Since the current system is a testbed, we also discuss future enhancements and outline two deployment scenarios (robotic and manual) for the final system to be designed and completed by the end of FY '95. An on-site demonstration is currently planned for Fernald in Ohio and Oak Ridge in Tennessee

  12. One stage rescue procedure after capsular contracture of breast implants with autologous fat grafts collected by water assisted liposuction (“BEAULI Method”

    Directory of Open Access Journals (Sweden)

    Ueberreiter, Klaus

    2013-01-01

    Full Text Available With increasing number of patients with silicone implants for breast augmentation or reconstruction we are confronted with more and more cases of capsular contracture. Not every case is resolved by resection of the capsule and exchange of implants. Many patients rather bear the consequences of severe fibrosis than to have their implants removed. The one stage procedure of implant removal and lipofilling proved to be highly efficient with good to excellent results and high patient satisfaction. Between January 2008 and October 2012 a total of 64 patients (124 breasts with capsular fibrosis Baker III to IV were treated with autologous fat grafts collected with the body-jet by water-assisted liposuction (“BEAULI Method”. Magnetic resonance imaging (MRI of the breasts was performed in 5 patients preoperatively and 6 month postoperatively, a clinical examination and photo documentation of all patients was done on day 1 and after 4 weeks, 12 weeks and 6 months postoperatively. The procedure included implant removal and lipofilling of the subcutaneous and intramuscular space in a single procedure by means of the BEAULI Method. The average gross amount of grafted fat was 260 ml. The average drainage time was one day. The shape of the breast changed to a more natural and ptotic form. Negative side effects like oily cysts or infections were not observed. The time of the overall procedure including liposuction was 70±15 min. Reoccurring capsular contracture is one of the hazards in plastic surgery. Until now the treatment of choice after more than two failed implant changes combined with resection of the capsule is usually the final removal of implants with or without possible additional autologous tissue transfer (microvascular flaps. We could add a relatively simple and efficient procedure to resolve and improve those cases by autologous fat transfer using water-assisted liposuction and the BEAULI Method.

  13. influence of early literacy parental involvement on science

    African Journals Online (AJOL)

    User

    were highly involved in their children's early literacy acquisition; parental ... in literacy acquisition of boys was more than that of girls, though this difference was not .... method. Procedure for Data Collection. The students (with the help of their.

  14. Genetically significant dose assessments of occupationally exposed individuals involved in industrial and medical radiographic procedures in certain establishments in Nigeria

    International Nuclear Information System (INIS)

    Jibiri, N.N.; Oguntade, G. T.

    2007-01-01

    The main source of radiation doses received by humans from man-made sources of ionizing radiation in medicine and industry comes from X-rays. The genetic risks of ionizing radiation effects on an individual who is occupationally exposed largely depend on the magnitude of the radiation dose received, period of practice, work load and radio logical procedures involved. In this work, using the linear non-thresh old model, we have attempted to assess the level of genetic risk of occupationally exposed individuals in two medical and industrial establishments in Nigeria by estimating their genetically significant dose values. The estimation was based on continuous personnel radiation dose monitoring data for the individuals in each of the establishments over a three year period (1998-2001). The estimated genetically significant dose values in the years considered were 12 mSv for the medical, and 29 mSv for the industrial personnel. Appropriate radiation protection precautions should be taken by the personnel to adhere to standard operational practices in order to minimize the genetically significant dose resulting from radio logical practices

  15. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    Science.gov (United States)

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  16. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    International Nuclear Information System (INIS)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-01-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  17. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-02-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  18. Llama oviductal sperm reservoirs: involvement of bulbourethral glands.

    Science.gov (United States)

    Apichela, S A; Argañaraz, M E; Giuliano, S; Zampini, R; Carretero, I; Miragaya, M; Miceli, D C

    2014-04-01

    The aim of this study was to elucidate the role of llama seminal plasma in the formation of oviductal sperm reservoirs. Female llamas with follicles in the mature phase were mated with a bulbourethral glands-removed male. Females mated with nonbulbourethral glands-removed males were used as control. Oviducts were obtained by surgery 24 h after mating. The uterotubal junction and isthmus were examined by scanning electron microscopy, and mucopolysaccharides were identified by Alcian blue staining. To know the proteins probably involved in sperm reservoir formation, SDS-PAGE of seminal plasma (8% and 18% resolving gel) was made. Spermatozoa only adhered to the oviductal mucosa surface of uterotubal junction of females mated with nonbulbourethral glands-removed males confirming that seminal plasma and, in particular, bulbourethral secretions are related with the oviductal sperm reservoir formation. Histological sections showed sperm in the lumen, immersed in substance, positive for acid mucopolysaccharides. Alcian blue staining of seminal plasma proteins SDS-PAGE showed a band of high molecular weight containing mucopolysaccharides, only present in nonbulbourethral glands-removed males. Bulbourethral glands would secrete at least eight different proteins that most likely participate in the process of sperm storage in the oviduct. © 2013 Blackwell Verlag GmbH.

  19. 75 FR 71353 - Office of the Attorney General; Certification Process for State Capital Counsel Systems; Removal...

    Science.gov (United States)

    2010-11-23

    ... the Attorney General; Certification Process for State Capital Counsel Systems; Removal of Final Rule... only if the Attorney General has certified ``that [the] State has established a mechanism for providing... State to qualify for the special habeas procedures, the Attorney General must determine that ``the State...

  20. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  1. [Removal of nitrate from groundwater using permeable reactive barrier].

    Science.gov (United States)

    Li, Xiu-Li; Yang, Jun-Jun; Lu, Xiao-Xia; Zhang, Shu; Hou, Zhen

    2013-03-01

    To provide a cost-effective method for the remediation of nitrate-polluted groundwater, column experiments were performed to study the removal of nitrate by permeable reactive barrier filled with fermented mulch and sand (biowall), and the mechanisms and influence factors were explored. The experimental results showed that the environmental condition in the simulated biowall became highly reduced after three days of operation (oxidation-reduction potential was below - 100 mV), which was favorable for the reduction of nitrate. During the 15 days of operation, the removal rate of nitrate nitrogen (NO3(-) -N) by the simulated biowall was 80%-90% (NO3(-)-N was reduced from 20 mg x L(-1) in the inlet water to 1.6 mg x L(-1) in the outlet water); the concentration of nitrite nitrogen (NO2(-) -N) in the outlet water was below 2.5 mg x L(-1); the concentration of ammonium nitrogen (NH4(+) -N) was low in the first two days but increased to about 12 mg x L(-1) since day three. The major mechanisms involved in the removal of nitrate nitrogen were adsorption and biodegradation. When increasing the water flow velocity in the simulated biowall, the removal rate of NO3(-) -N was reduced and the concentration of NH4(+) -N in the outlet water was significantly reduced. A simulated zeolite wall was set up following the simulated biowall and 98% of the NH4(+) -N could be removed from the water.

  2. Removal of congo red and methylene blue from waste water using coagulation

    International Nuclear Information System (INIS)

    Ghaffar, S.; Nosheen, S.; Ahmad, N.

    2011-01-01

    The textile industry has been condemned as being one of the world's worst offenders in terms of pollution Because of increasing population and industrial developments, a huge amount of wastewater is discharged to the environment above the level that the nature can eliminate. Many techniques like oxidation, reduction, physical treatment and biological method are available for removal of colored dyes from wastewater. The work presented here involved the decolorisation of wastewater containing congo red and methylene blue using various coagulants such as alum, bentonite and lime. The effect of various experimental factors such as dosage of coagulants, contact time between coagulant and dye and concentration of dyes and working environment like shaking and static was studied. Under static condition alum give almost 43% removal of congo red while with 10 minutes shaking 74 % removal of 80 dye was achieved with same coagulant. The highest removal of congo red was found to be 99.5 % by using alum after 30 minutes of shaking but in case of methylene blue it intensified the color and gave negative results. Lime gave only 33 % color removal of congo red under static conditions while 57% color was removed under shaking conditions. Maximum color removal achieved by lime was 89% at 40 minutes with shaking condition. Lime gave 60% removal of methylene blue in static condition and 90% removal in shaking condition and maximum absorbance at 80 ppm was 90%. Bentonite also used for the removal of methylene blue and gave 89% removal in shaking condition. By increasing shaking time %age removal increased to 100% at 40 min. And amount of coagulant increased the removal efficiency it attained 100% in both lime and bentonite coagulant for methylene blue Overall alum was found to be better coagulant for the removal of congo red from its aqueous solution. Lime and bentonite both proved better and economical for removal of methylene blue from aqueous solution at lab scale. (author)

  3. Modified Distal Urethral Polypropylene Sling (Canal Transobturator Tape Procedure: Efficacy for Persistent Stress Urinary Incontinence After a Conventional Midurethral Sling Procedure

    Directory of Open Access Journals (Sweden)

    Chang Hee Kim

    2013-03-01

    Full Text Available Purpose: Despite reports of persistent stress urinary incontinence (SUI in patients after the midurethral sling (MUS procedure, there is no widely accepted definition or cause of the condition. In many cases, the mesh implanted in the previous MUS procedure has been found to have migrated proximally. The aim of this study was to evaluate the efficacy of the modified distal urethral polypropylene sling, or canal transobturator tape (TOT, procedure for persistent SUI after a conventional MUS procedure on the assumption that persistent SUI after MUS is due to the location of the sling. Methods: From January 2008 to April 2012, 31 female patients who underwent the canal TOT procedure presented with incontinence or lower urinary tract symptoms (LUTS were included in this study. We identified patients who had been operated on by use of the conventional MUS procedure at other medical facilities, whose Valsalva leak pressure point was less than 120 cm-H2O by urodynamic study, and who were also diagnosed with persistent SUI. If vaginal or urethral mesh exposure was concomitant with persistent SUI, the mesh was removed completely or in part. Surgical procedures for canal TOT were identical to the original TOT procedures, except in the number and location of the vaginal incisions. Incontinence Impact Questionnaire-Short Form (IIQ-7 and Urogenital Distress Inventory-Short Form (UDI-6 scores were assessed preoperatively and at 3 months postoperatively. Results: There were no intraoperative or postoperative complications. Twenty-eight patients (90.3% showed improvement in incontinence or other LUTS. Postoperative scores of the IIQ-7 (0.65±0.48 and UDI-6 (3.48±2.28 were significantly improved compared with preoperative scores (1.26±0.58 and 7.52±4.30, respectively; P<0.05. Conclusions: Improper sling location is one of the major causes of persistent SUI after the conventional MUS procedure. Our results demonstrate that canal TOT may be an alternative

  4. Total thyroidectomy as primary elective procedure in multinodular thyroid disease

    International Nuclear Information System (INIS)

    Sheikh, I.A.; Haider, I.Z.; Haroon, A.; Ashfaq, M.

    2009-01-01

    Multinodular goitre is one of the commonest thyroid diseases encountered in the practice of surgery. The most common surgery being performed for multinodular goitre is subtotal thyroidectomy. Total thyroidectomy is designed to remove all of the thyroid tissue. The objective of this study was to evaluate total thyroidectomy as a primary elective procedure for treatment of multinodular thyroid disease. This descriptive study was carried out at Combined Military Hospital Rawalpindi from June 2003 to September 2006. 88 patients of multinodular thyroid disease were included. Patients having evidence of recurrent laryngeal nerve damage, recurrent goitre, evidence of altered parathyroid functions or evidence of malignancy were excluded. All patients underwent total thyroidectomy by the same team of surgeons and the patients were closely followed up for postoperative complications especially in terms of recurrent laryngeal nerve damage and hypocalcaemic tetany. No major postoperative complication was noted. Only 1 patient (1.14%) developed unilateral recurrent laryngeal nerve damage and 2 patients (2.27%) developed transient hypocalcaemia that recovered quickly. Total thyroidectomy as a primary elective procedure in multinodular thyroid disease is a safe option and it removes the disease process completely, lowers local recurrence rates and avoids the substantial risks of re operative surgery. (author)

  5. Mercury removal from water streams through the ion exchange membrane bioreactor concept.

    Science.gov (United States)

    Oehmen, Adrian; Vergel, Dario; Fradinho, Joana; Reis, Maria A M; Crespo, João G; Velizarov, Svetlozar

    2014-01-15

    Mercury is a highly toxic heavy metal that causes human health problems and environmental contamination. In this study, an ion exchange membrane bioreactor (IEMB) process was developed to achieve Hg(II) removal from drinking water and industrial effluents. Hg(II) transport through a cation exchange membrane was coupled with its bioreduction to Hg(0) in order to achieve Hg removal from concentrated streams, with minimal production of contaminated by-products observed. This study involves (1) membrane selection, (2) demonstration of process effectiveness for removing Hg from drinking water to below the 1ppb recommended limit, and (3) process application for treatment of concentrated water streams, where >98% of the Hg was removed, and the throughput of contaminated water was optimised through membrane pre-treatment. The IEMB process represents a novel mercury treatment technology with minimal generation of contaminated waste, thereby reducing the overall environmental impact of the process. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Preparation of fly ash based zeolite for removal of fluoride from drinking water

    Science.gov (United States)

    Panda, Laxmidhar; Kar, Biswabandita; Dash, Subhakanta

    2018-05-01

    Fluoride contamination of drinking water is a worldwide phenomenon and scientists are working relentlessly to find ways to remove fluoride from drinking water. Out of the different methods employed for removal fluoride from drinking water adsorption process is the most suitable because in this process the adsorbent is regenerated and the process is cost effective. In the present study fly ash is used as the raw material, which is treated with alkali (NaOH) to form NaP1 zeolite. This zeolite is then subjected to characterization by standard procedures. It is found that the synthesized zeolite has more crystalline character than the raw fly ash and has also more voids and channels on its surface. The surface of the synthesized zeolite is modified with calcium chloride and the same is employed for removal of fluoride under varying pH, contact time, initial concentration of fluoride, temperature and adsorbent dose etc so as to assess the suitably or otherwise of the synthesized product.

  8. Soni-removal of nucleic acids from inclusion bodies.

    Science.gov (United States)

    Neerathilingam, Muniasamy; Mysore, Sumukh; Gandham, Sai Hari A

    2014-05-23

    Inclusion bodies (IBs) are commonly formed in Escherichia coli due to over expression of recombinant proteins in non-native state. Isolation, denaturation and refolding of these IBs is generally performed to obtain functional protein. However, during this process IBs tend to form non-specific interactions with sheared nucleic acids from the genome, thus getting carried over into downstream processes. This may hinder the refolding of IBs into their native state. To circumvent this, we demonstrate a methodology termed soni-removal which involves disruption of nucleic acid-inclusion body interaction using sonication; followed by solvent based separation. As opposed to conventional techniques that use enzymes and column-based separations, soni-removal is a cost effective alternative for complete elimination of buried and/or strongly bound short nucleic acid contaminants from IBs. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Infectious morbidity, operative blood loss, and length of the operative procedure after cesarean delivery by method of placental removal and site of uterine repair.

    Science.gov (United States)

    Magann, E F; Washburne, J F; Harris, R L; Bass, J D; Duff, W P; Morrison, J C

    1995-12-01

    This study was done to determine the impact of the method of placental removal and the site of uterine repair on postcesarean infectious morbidity rates in women receiving prophylactic antibiotics at cesarean delivery. This prospective study included 284 women who underwent cesarean delivery and who were randomly assigned to four groups based on the method of placental removal and the site of uterine repair: group 1, spontaneous placental removal and in situ uterine repair; group 2, spontaneous placental removal and exteriorized uterine repair; group 3, manual placental removal and in situ uterine repair; and group 4, manual placental removal with exteriorized uterine repair. Exclusion criteria were repeat cesarean deliveries without labor, active infection at the time of cesarean delivery, and patient refusal to participate. There was no significant difference among the groups in maternal age, race, parity, weight, the length of time from rupture of membranes (ROM) or the number of vaginal examinations from ROM to cesarean delivery, or preoperative hematocrit. Intraoperatively, the type of uterine incision, anesthesia administered, incidence of meconium-stained amniotic fluid, Apgar scores, and cord gases were similar between groups. The incidence of postcesarean endometritis was greater in group 4 (32 [45 percent] of 71, p = 0.003) compared with group 1 (17 [24 percent] of 71), group 2 (12 [30 percent] of 71); and group 3 (13 [18 percent] of 71). Manual placental removal and exteriorization of the uterus for repair of the surgical incision increases the infectious morbidity rate in women receiving prophylactic antibiotics at the time of cesarean delivery and increases the length of hospitalization.

  10. Mechanisms of radical removal by SO2

    DEFF Research Database (Denmark)

    Rasmussen, Christian Lund; Glarborg, Peter; Marshall, Paul

    2007-01-01

    It is well established from experiments in premixed, laminar flames, jet-stirred reactors, flow reactors, and batch reactors that SO2 acts to catalyze hydrogen atom removal at stoichiometric and reducing conditions. However, the commonly accepted mechanism for radical removal, SO2 + H......(+M) reversible arrow HOSO(+M), HOSO + H/OH reversible arrow SO2 + H-2/H2O, has been challenged by recent theoretical and experimental results. Based on ab initio calculations for key reactions, we update the kinetic model for this chemistry and re-examine the mechanism of fuel/SO2 interactions. We find...... that the interaction of SO, with the radical pool is more complex than previously assumed, involving HOSO and SO, as well as, at high temperatures also HSO, SH, and S. The revised mechanism with a high rate constant for H + SO2 recombination and with SO + H2O, rather than SO2 + H-2, as major products of the HOSO + H...

  11. Improving the development, use and control of maintenance procedures

    International Nuclear Information System (INIS)

    Morgenstern, M.H.; Barnes, V.E.; Radford, L.R.; Wheeler, W.A.; Badalamente, R.V.

    1985-12-01

    This paper describes the results of a project conducted for the US Nuclear Regulatory Commission (NRC) to assess and document the need for guidance or regulatory involvement by the NRC in the development, upgrading, use and control of maintenance procedures in US nuclear power plants. Presented are the findings of the following activities: (1) a survey of current maintenance procedure practices in seven US nuclear power plants; (2) a review and analysis of plant administrative and maintenance procedures; (3) a survey of maintenance procedure practices in industries that share some characteristics with the nuclear industry; and (4) a review of the research pertaining to job performance aids and a brief analysis of their applicability to maintenance in nuclear power plants. Based on these findings, several recommendations to upgrade maintenance procedures are offered

  12. Eisenia fetida increased removal of polycyclic aromatic hydrocarbons from soil

    Energy Technology Data Exchange (ETDEWEB)

    Silvia M. Contreras-Ramos; Dioselina Alvarez-Bernal; Luc Dendooven [Laboratory of Soil Ecology, Department of Biotechnology and Bioengineering, Mexico (Mexico)

    2006-06-15

    The removal of phenanthrene, anthracene and benzo(a)pyrene added at three different concentrations was investigated with or without earthworms (Eisenia fetida) within 11 weeks. Average anthracene removal by the autochthonous micro-organisms was 23%, 77% for phenanthrene and 13% for benzo(a)pyrene, while it was 51% for anthracene, 47% for benzo(a)pyrene and 100% for phenanthrene in soil with earthworms. At 50 and 100 mg phenanthrene kg{sup -1} E. fetida survival was 91% and 83%, but at 150 mg kg{sup -1} all died within 15 days. Survival of E. fetida in soil amended with anthracene {<=}1000 mg kg{sup -1} and benzo(a)pyrene {<=}150 mg kg{sup -1} was higher than 80% and without weight loss compared to the untreated soil. Only small amounts of PAHs were detected in the earthworms. It was concluded that E. fetida has the potential to remove large amounts of PAHs from soil, but more work is necessary to elucidate the mechanisms involved.

  13. Surgical removal of intra-abdominal intrauterine devices at one center in a 20-year period.

    Science.gov (United States)

    Ertopcu, Kenan; Nayki, Cenk; Ulug, Pasa; Nayki, Umit; Gultekin, Emre; Donmez, Aysegul; Yildirim, Yusuf

    2015-01-01

    To review 20 years of experience of the removal of intra-abdominal intrauterine devices (IUDs) and to compare the surgical methods used. In a retrospective study, charts dating from between September 1, 1992, and August 31, 2012, were reviewed. Patients were eligible for inclusion when they had an IUD surgically removed by minilaparotomy or laparoscopy at a tertiary referral center in Izmir, Turkey. Among the 36 eligible women, 18 (50%) had undergone laparoscopy and 18 (50%) had undergone minilaparotomy. Mean operation length was 55.3±6.3 minutes in the laparoscopy group and 29.1±4.2 minutes in the minilaparotomy group (P=0.008). Conversion to full laparotomy was necessary in 4 (22%) women in the laparoscopy group and 1 (6%) in the minilaparotomy group (P=0.02). Perioperative complications were observed in 5 (14%) women, with no difference in frequency between groups (P=0.09). Total cost of medical/surgical procedures was US$436.4±35.4 for the laparoscopy group and $323.4±21.3 for the minilaparotomy group (P=0.04). Minilaparotomy seems to be an important alternative to laparoscopy for the removal of intra-abdominal IUDs. This procedure should be an integral part of gynecologic surgical training. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Influence of luting agents on time required for cast post removal by ultrasound: an in vitro study

    Directory of Open Access Journals (Sweden)

    Janir Alves Soares

    2009-06-01

    Full Text Available OBJECTIVE: This in vitro study evaluated the influence of luting agents on ultrasonic vibration time for intraradicular cast post removal. MATERIAL AND METHODS: After endodontic treatment, 30 roots of extracted human canines were embedded in resin cylinders. The post-holes were prepared at 10 mm depth and their impressions were taken using autopolymerizing acrylic resin. After casting procedures using a nickel-chromium alloy, the posts were randomly distributed into 3 groups (n=10 according to the luting material: G1- zinc phosphate (SS White (control group, G2 - glass ionomer cement (Vidrion C; SS White, and G3- resin cement (C&B; Bisco. In G3, the adhesive procedure was performed before post cementation. After 24 h, the cement line was removed at the post/tooth interface using a fine diamond bur, and the ST-09 tip of an Enac ultrasound unit was applied at maximum power on all surfaces surrounding the posts. The application time was recorded with a chronometer until the post was completely dislodged and data were analyzed by ANOVA and Tukey's test (p<0.05. RESULTS: The roots were removed from the acrylic resin and inspected to detect cracks and/or fractures. The means for G1, G2, and G3 were 168.5, 59.5, and 285 s, respectively, with statistically significant differences among them. Two G3 posts resisted removal, one of which developed a vertical fracture line. CONCLUSIONS: Therefore, the cement type had a direct influence on the time required for ultrasonic post removal. Compared to the zinc phosphate and glass ionomer cements, the resin cement required a longer ultrasonic vibration time.

  15. Research on removal of radioiodine by charcoal

    International Nuclear Information System (INIS)

    Li Wangchang; Huang Yuying; Wu Yianwei; Jia Ming; Guo Liangtian

    1993-01-01

    The major R and D work carried out in the CIRP laboratory on removal of radioiodine is introduced, which involves the adsorption performances of various kinds of fruit shell base and coal base charcoal impregnated with chemicals, the influence of various parameters, the technique of non-destructive test for commercial scale iodine adsorber, and the iodine samplers for both gross iodine and iodine in different forms. The experimental results have been applied to the design and test of iodine adsorber and the monitoring of airborne radioiodine

  16. Effects of water chemistry on arsenic removal from drinking water by electrocoagulation.

    Science.gov (United States)

    Wan, Wei; Pepping, Troy J; Banerji, Tuhin; Chaudhari, Sanjeev; Giammar, Daniel E

    2011-01-01

    Exposure to arsenic through drinking water poses a threat to human health. Electrocoagulation is a water treatment technology that involves electrolytic oxidation of anode materials and in-situ generation of coagulant. The electrochemical generation of coagulant is an alternative to using chemical coagulants, and the process can also oxidize As(III) to As(V). Batch electrocoagulation experiments were performed in the laboratory using iron electrodes. The experiments quantified the effects of pH, initial arsenic concentration and oxidation state, and concentrations of dissolved phosphate, silica and sulfate on the rate and extent of arsenic removal. The iron generated during electrocoagulation precipitated as lepidocrocite (γ-FeOOH), except when dissolved silica was present, and arsenic was removed by adsorption to the lepidocrocite. Arsenic removal was slower at higher pH. When solutions initially contained As(III), a portion of the As(III) was oxidized to As(V) during electrocoagulation. As(V) removal was faster than As(III) removal. The presence of 1 and 4 mg/L phosphate inhibited arsenic removal, while the presence of 5 and 20 mg/L silica or 10 and 50 mg/L sulfate had no significant effect on arsenic removal. For most conditions examined in this study, over 99.9% arsenic removal efficiency was achieved. Electrocoagulation was also highly effective at removing arsenic from drinking water in field trials conducted in a village in Eastern India. By using operation times long enough to produce sufficient iron oxide for removal of both phosphate and arsenate, the performance of the systems in field trials was not inhibited by high phosphate concentrations. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Aqueous arsenite removal by simultaneous ultraviolet photocatalytic oxidation-coagulation of titanium sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuxia [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Duan, Jinming, E-mail: jinmingduan@xauat.edu.cn [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia); Li, Wei [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Beecham, Simon; Mulcahy, Dennis [Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia)

    2016-02-13

    Highlights: • A simultaneous UV catalysed oxidation–coagulation for As(III) removal is proposed. • As(III) was effectively oxidised to As(V) by the UV catalysed coagulation. • >99% removal for As(III) in pH 4–6 at low doses of Ti(SO{sub 4}){sub 2} was achieved. • Concurrent UV radiation in massive small crystal formation facilitate the effects. • Reaction mechanisms involve both hydroxyl radicals and superoxide radicals. - Abstract: This study explored the efficacy and efficiency of a simultaneous UV-catalyzed oxidation–coagulation process of titanium sulfate (UV/Ti(SO{sub 4}){sub 2}) for efficient removal of As(III) from water. It revealed that, As(III) could be oxidized to As(V) during the UV catalyzed coagulation of Ti(SO{sub 4}){sub 2} with highly efficient As(III) removal in the pH range 4–6{sub .} The UV catalyzed oxidation–coagulation showed surprisingly effective oxidation of As(III) to As(V) within a short time. XPS indicated that 84.7% of arsenic on the coagulated precipitate was in the oxidized form of As(V) after the UV/Ti(SO{sub 4}){sub 2} treatment of As(III) aqueous solutions at pH 5. Arsenic remaining in solution at high pH was in the oxidized form As(V). Removal efficiencies of As(III) were investigated as a function of pH, Ti(SO{sub 4}){sub 2} dosage, initial As(III) concentration and irradiation energy. As(III) could almost completely be removed (>99%) by the photocatalytic oxidation–coagulation process with a moderate dose of Ti(SO{sub 4}){sub 2} in the pH range 4–6 at an initial arsenic concentration of 200 μg/L. The mechanisms of the photocatalytic coagulation oxidation of Ti(SO{sub 4}){sub 2} are similar to those of UV/crystalline TiO{sub 2} particles, involving the formation and reactions of the hydroxyl radical OH· and superoxide HO{sub 2}·/O{sub 2}{sup ·−}.

  18. Application of CO II laser for removal of oral mucocele

    Science.gov (United States)

    Kato, J.; Moriya, K.; Hirai, Y.

    2006-02-01

    Mucocele is an oral soft tissue cyst caused by the disturbance of saliva flow. Mucocele is widely observed in child patients and recurrence is high. The objective of this study was to clarify the effect of CO II laser irradiation in the case of mucocele. A CO II laser was used on 45 subjects, aged between 0 to 15 years, having mucocele on lip, lingual, or buccal mucosa. Our procedure in using CO II laser was not to vaporize the mucocele but to remove the whole mucocele mass. The border of mucocele was firstly incised by laser following defocusly ablating the root or body of mucocele separating from sorrounding tissue. As a result, mucocele was easily and completely removed without breaking the wall of mucocele. None of the cases required suturing. The results were as follows. 1. The mucocele of lip or lingual mucosa with a rich blood supply, was efficiently removed, without bleeding, giving a clear operative field during the operation. 2. The surgery itself was simple and less time-consuming. 3. After two or three weeks the wound was completely healed without almost any discomfort in all patients 4. Wound contraction and scarring were decreased or eliminated. 5. The reoccurrence of mucocele was not seen, except only in one case of lingual mucocele. In conclusion the use of CO II laser proved to be a very safe and effective mode for the removal of mucocele, especially in small children.

  19. Metal and metalloid removal in constructed wetlands, with emphasis on the importance of plants and standardized measurements: A review

    International Nuclear Information System (INIS)

    Marchand, L.; Mench, M.; Jacob, D.L.; Otte, M.L.

    2010-01-01

    This review integrates knowledge on the removal of metals and metalloids from contaminated waters in constructed wetlands and offers insight into future R and D priorities. Metal removal processes in wetlands are described. Based on 21 papers, the roles and impacts on efficiency of plants in constructed wetlands are discussed. The effects of plant ecotypes and class (monocots, dicots) and of system size on metal removal are addressed. Metal removal rates in wetlands depend on the type of element (Hg > Mn > Fe = Cd > Pb = Cr > Zn = Cu > Al > Ni > As), their ionic forms, substrate conditions, season, and plant species. Standardized procedures and data are lacking for efficiently comparing properties of plants and substrates. We propose a new index, the relative treatment efficiency index (RTEI), to quantify treatment impacts on metal removal in constructed wetlands. Further research is needed on key components, such as effects of differences in plant ecotypes and microbial communities, in order to enhance metal removal efficiency. - A new index, the relative treatment efficiency index (RTEI), to quantify treatment impacts on metal and metalloid removal in constructed wetlands.

  20. Removal of a Broken Cannulated Intramedullary Nail: Review of the Literature and a Case Report of a New Technique

    Directory of Open Access Journals (Sweden)

    Amr A. Abdelgawad

    2013-01-01

    Full Text Available Nonunion of long bones fixed with nails may result in implant failure. Removal of a broken intramedullary nail may be a real challenge. Many methods have been described to allow for removal of the broken piece of the nail. In this paper, we are reviewing the different techniques to extract a broken nail, classifying them into different subsets, and describing a new technique that we used to remove a broken tibial nail with narrow canal. Eight different categories of implant removal methods were described, with different methods within each category. This classification is very comprehensive and was never described before. We described a new technique (hook captured in the medulla by flexible nail introduced from the locking hole which is a valuable technique in cases of nail of a small diameter where other methods cannot be used because of the narrow canal of the nail. Our eight categories for broken nail removal methods simplify the concepts of nail removal and allow the surgeon to better plan for the removal procedure.

  1. 8 CFR 1208.31 - Reasonable fear of persecution or torture determinations involving aliens ordered removed under...

    Science.gov (United States)

    2010-01-01

    ... OFFICE FOR IMMIGRATION REVIEW, DEPARTMENT OF JUSTICE IMMIGRATION REGULATIONS PROCEDURES FOR ASYLUM AND... provide the alien with an opportunity to correct errors therein. The asylum officer shall create a written... the authority described in § 1208.9(c). (e) Referral to Immigration Judge. If an asylum officer...

  2. 42 CFR 423.564 - Grievance procedures.

    Science.gov (United States)

    2010-10-01

    ... the grievance procedures of the Part D plan sponsor. For quality of care issues, an enrollee may file... quality of care, regardless of how the grievance is filed, must be responded to in writing. The response... hours if the complaint involves a refusal by the Part D plan sponsor to grant an enrollee's request for...

  3. Radioimmunoassay procedure using a stabilized complex

    International Nuclear Information System (INIS)

    Sultanian, I.V.; Irani, J.H.

    1978-01-01

    An improved radioimmunoassay procedure involves the use of a stabilized complex of labelled antigen and antibody which has an extended shelf life as compared to the same complex absent the stabilizers. Since the time needed to incubate the mixture of labelled antigen and antibody is eliminated, the time for completing the assay is considerably shortened and simplified. The components for carrying out the procedure are packaged in a kit basically including standard antigen for generation of a standard curve, a stabilized labelled antigen-antibody complex and reference serum, if used. A plurality of stabilizers are used in the complex to provide a shelf life of six weeks or more. 10 claims

  4. PLANNING YOUR REMOVALS

    CERN Multimedia

    Service déménagement; ST Division

    1999-01-01

    To give you better service and avoid lengthy delays, the Removals Service advises you to refrain from programming moves between 26 July and 3 September, as large-scale removals are already planned during this summer period.Thanking you in advance for your co-operation and understanding.Removals Service STTel. 74185 / Mobile 164017

  5. Recent developments in the biochemistry and ecology of enhanced biological phosphorus removal

    NARCIS (Netherlands)

    Kortstee, GJJ; Appeldoorn, KJ; Bonting, CFC; van Niel, EWJ; van Veen, HW

    Most of the genes encoding the enzymes involved in polyP synthesis and degradation and in phosphate transport have been studied in various Gram-negative bacteria. Progress has also been made in studying the biochemical mechanisms underlying the process of enhanced biological phosphorus removal

  6. Recent developments in the biochemistry and ecology of enhanced biological phosphorus removal

    NARCIS (Netherlands)

    Kortstee, G.J.J.; Appeldoorn, K.J.; Bonting, C.F.C.; Niel, van E.W.J.; Veen, van H.W.

    2000-01-01

    Most of the genes encoding the enzymes involved in polyP synthesis and degradation and in phosphate transport have been studied in various Gram-negative bacteria. Progress has also been made in studying the biochemical mechanisms underlying the process of enhanced biological phosphorus removal

  7. ARSENIC REMOVAL FROM DRINKING WATER BY COAGULATION/FILTRATION AND LIME SOFTENING PLANTS

    Science.gov (United States)

    This report documents a long term performance (one year) study of 3 water treatment plants to remove arsenic from drinking water sources. The 3 plants consisted of 2 conventional coagulation/filtration plants and 1 lime softening plant. The study involved the collecting of weekly...

  8. Percutaneous removal of pulmonary artery emboli with hydrolyser catheter in pigs

    International Nuclear Information System (INIS)

    Lacoursiere, L.; Millward, S.; Veinot, J.P.; Labinaz, M.

    2001-01-01

    To evaluate the efficacy and safety of the Hydrolyser catheter for per,cutaneous treatment of massive pulmonary embolism in pigs. Twelve pigs, each weighing between 55 kg and 89 kg, were used. Radio-opaque 9 cm x 0.8 cm and 4.5 cm x 0.8 cm clots, produced by mixing pig blood with iodinated contrast agent in vacutainers, were injected via the jugular vein until central pulmonary embolism (main and proximal lobar arteries) was obtained with significant systemic and pulmonary hemodynamic modifications. From a femoral approach, the 7-French Hydrolyser thrombectomy catheter was run over a 0.025-inch (0.64-mm) guide wire to remove the pulmonary emboli. Hemodynamic, gasometric and angiographic monitoring was performed before and after treatment. The procedure's safety and completeness of emboli removal was assessed by cardiopulmonary autopsy. Three of the 12 pigs died during embolization. Thrombectomy was therefore performed in 9, and central emboli could be obtained in 7 of the 9. The Hydrolyser could be manipulated only in central pulmonary arteries and could aspirate only central emboli in 5 of the 7 pigs that had them. Despite minimal angiographic improvement seen in these 5, there was no significant hemodynamic and gasometric improvement after treatment. The procedure induced an increase in free hemoglobin blood levels. Autopsies revealed an average of 2 endothelial injuries per pig (mainly adherent endocardial thrombi) in both nontreated (n = 3) and Hydrolyser-treated (n = 9) groups. The Hydrolyser thrombectomy catheter can be promptly positioned and easily steered in central pulmonary arteries. It can be used to partially remove central emboli, but not peripheral pulmonary emboli. Most of the injuries observed may not have been strictly related to Hydrolyser use. The pig might not be a suitable animal model for treatment of massive pulmonary embolism. (author)

  9. Unburnt carbon from coal fly ashes as a precursor of activated carbon for nitric oxide removal.

    Science.gov (United States)

    Rubio, Begoña; Izquierdo, M Teresa; Mayoral, M Carmen; Bona, M Teresa; Andres, Jose M

    2007-05-08

    The aim of this work is to evaluate the characteristics of an activated carbon obtained from unburnt carbon in coal fly ashes to be used in the removal of NO. Carbon-rich fraction was obtained by mechanical sieving of fly ashes. The mineral matter was removed by conventional HCl and HF demineralization procedure. Activation was carried out with steam at 900 degrees C in order to develop porosity onto the sample. Characterization of samples was performed by several techniques with a main objective: to follow the mineral matter content, composition and distribution on the samples in order to better understand how to remove it from unburnt carbon in fly ashes. To study the use of this unburnt carbon as a precursor for the preparation of activated carbons for gas cleaning, the NO removal by ammonia using activated carbon as a catalyst at low temperature was performed. Results show a good performance of activated carbon in this reaction that is in relationship with BET surface area.

  10. Procedures monitoring and MAAP analysis

    International Nuclear Information System (INIS)

    May, R.S.

    1991-01-01

    Numerous studies of severe accidents in light water reactors have shown that operator response can play a crucial role in the predicted outcomes of dominant accident scenarios. MAAP provides the capability to specify certain operator actions as input data. However, making reasonable assumptions about the nature and timing of operator response requires substantial knowledge about plant practices and procedures and what they imply for the event being analyzed. The appearance of knowledge based software technology in the mid-1980s provided a natural format for representing and maintaining procedures as IF-THEN rules. The boiling water reactor (BWR) Emergency Operating Procedures Tracking System (EOPTS) was composed of a rule base of procedures and a dedicated inference engine (problem-solver). Based on the general approach and experience of EOPTS, the authors have developed a prototype procedures monitoring system that reads MAAP transient output files and evaluate the EOP messages and instructions that would be implied during each transient time interval. The prototype system was built using the NEXPERT OBJECT expert system development system, running on a 386-class personal computer with 4 MB of memory. The limited scope prototype includes a reduced set of BWR6 EOPs procedures evaluation on a coarse time interval, a simple text-based user interface, and a summary-report generator. The prototype, which is limited to batch-mode analysis of MAAP output, is intended to demonstrate the concept and aid in the design of a production system, which will involve a direct link to MAAP and interactive capabilities

  11. An Approach to Remove the Systematic Bias from the Storm Surge forecasts in the Venice Lagoon

    Science.gov (United States)

    Canestrelli, A.

    2017-12-01

    In this work a novel approach is proposed for removing the systematic bias from the storm surge forecast computed by a two-dimensional shallow-water model. The model covers both the Adriatic and Mediterranean seas and provides the forecast at the entrance of the Venice Lagoon. The wind drag coefficient at the water-air interface is treated as a calibration parameter, with a different value for each range of wind velocities and wind directions. This sums up to a total of 16-64 parameters to be calibrated, depending on the chosen resolution. The best set of parameters is determined by means of an optimization procedure, which minimizes the RMS error between measured and modeled water level in Venice for the period 2011-2015. It is shown that a bias is present, for which the peaks of wind velocities provided by the weather forecast are largely underestimated, and that the calibration procedure removes this bias. When the calibrated model is used to reproduce events not included in the calibration dataset, the forecast error is strongly reduced, thus confirming the quality of our procedure. The proposed approach it is not site-specific and could be applied to different situations, such as storm surges caused by intense hurricanes.

  12. Mental Procedures in Real-Life Tasks: A Case of Electronic Trouble Shooting

    DEFF Research Database (Denmark)

    Rasmussen, Jens; Jensen, A.

    1974-01-01

    be broken down into a sequence of recurrent search routines. Basically different typos of such routines are found with great differences in respect to the number of observations needed and the complexity of the mental data processing involved. They also differ greatly with respect to the depth of knowledge......The mental procedures used by skilled electronics repair men in their normal working environment have been studied by analysis of verbal protocols. The procedures found are organized as a search through a system which is viewed as a hierarchy of subunits. The general structure of the search can...... less of whether observations are informationally redundant or not. Seen from the viewpoint of information economy, the procedures are inefficient, but if the men are supposed to minimize the time spent ill the task and the mental load involved, the procedures are very rational. The records indicate...

  13. Percutaneous Cystgastrostomy as a Single-Step Procedure

    International Nuclear Information System (INIS)

    Curry, L.; Sookur, P.; Low, D.; Bhattacharya, S.; Fotheringham, T.

    2009-01-01

    The purpose of this study was to evaluate the success of percutaneous transgastric cystgastrostomy as a single-step procedure. We performed a retrospective analysis of single-step percutaneous transgastric cystgastrostomy carried out in 12 patients (8 male, 4 female; mean age 44 years; range 21-70 years), between 2002 and 2007, with large symptomatic pancreatic pseudocysts for whom up to 1-year follow-up data (mean 10 months) were available. All pseudocysts were drained by single-step percutaneous cystgastrostomy with the placement of either one or two stents. The procedure was completed successfully in all 12 patients. The pseudocysts showed complete resolution on further imaging in 7 of 12 patients with either enteric passage of the stent or stent removal by endoscopy. In 2 of 12 patients, the pseudocysts showed complete resolution on imaging, with the stents still noted in situ. In 2 of 12 patients, the pseudocysts became infected after 1 month and required surgical intervention. In 1 of 12 patients, the pseudocyst showed partial resolution on imaging, but subsequently reaccumulated and later required external drainage. In our experience, percutaneous cystgastrostomy as a single-step procedure has a high success rate and good short-term outcomes over 1-year follow-up and should be considered in the treatment of large symptomatic cysts.

  14. Optimization of graffiti removal on natural stone by means of high repetition rate UV laser

    International Nuclear Information System (INIS)

    Fiorucci, M.P.; López, A.J.; Ramil, A.; Pozo, S.; Rivas, T.

    2013-01-01

    The use of laser for graffiti removal is a promising alternative to conventional cleaning methods, though irradiation parameters must be carefully selected in order to achieve the effective cleaning without damaging the substrate, especially when referring to natural stone. From a practical point of view, once a safe working window is selected, it is necessary to determine the irradiation conditions to remove large paint areas, with minimal time consumption. The aim of this paper is to present a systematic procedure to select the optimum parameters for graffiti removal by means of the 3rd harmonic of a high repetition rate nanosecond Nd:YVO 4 laser. Ablation thresholds of four spray paint colors were determined and the effect of pulse repetition frequency, beam diameter and line scan separation was analyzed, obtaining a set of values which optimize the ablation process.

  15. Optimization of graffiti removal on natural stone by means of high repetition rate UV laser

    Energy Technology Data Exchange (ETDEWEB)

    Fiorucci, M.P., E-mail: m.p.fiorucci@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain); López, A.J., E-mail: ana.xesus.lopez@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Ramil, A., E-mail: alberto.ramil@udc.es [Centro de Investigacións Tecnolóxicas, Universidade da Coruña, 15403 Ferrol (Spain); Pozo, S., E-mail: ipozo@uvigo.es [Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain); Rivas, T., E-mail: trivas@uvigo.es [Dpto. Enxeñaría dos Recursos Naturais e Medio Ambiente, E.T.S.E. Minas, Universidade de Vigo, 36200 Vigo (Spain)

    2013-08-01

    The use of laser for graffiti removal is a promising alternative to conventional cleaning methods, though irradiation parameters must be carefully selected in order to achieve the effective cleaning without damaging the substrate, especially when referring to natural stone. From a practical point of view, once a safe working window is selected, it is necessary to determine the irradiation conditions to remove large paint areas, with minimal time consumption. The aim of this paper is to present a systematic procedure to select the optimum parameters for graffiti removal by means of the 3rd harmonic of a high repetition rate nanosecond Nd:YVO{sub 4} laser. Ablation thresholds of four spray paint colors were determined and the effect of pulse repetition frequency, beam diameter and line scan separation was analyzed, obtaining a set of values which optimize the ablation process.

  16. Paediatric minor oral surgical procedures under inhalation sedation and general anaesthetic: a comparison of variety and duration of treatment.

    Science.gov (United States)

    Foley, J

    2008-03-01

    To develop baseline data in relation to paediatric minor oral surgical procedures undertaken with both general anaesthesia and nitrous oxide inhalation sedation within a Hospital Dental Service. Data were collected prospectively over a three-year period from May 2003 to June 2006 for patients attending the Departments of Paediatric Dentistry, Dundee Dental Hospital and Ninewells Hospital, NHS Tayside, Great Britain, for all surgical procedures undertaken with either inhalation sedation or general anaesthetic. Both operator status and the procedure being undertaken were noted. In addition, the operating time was recorded. Data for 166 patients (F: 102; M: 64) with a median age of 12.50 (inter-quartile range 10.00, 14.20) years showed that 195 surgical procedures were undertaken. Of these 160 and 35 were with general anaesthetic and sedation respectively. The surgical removal of impacted, carious and supernumerary unit(s) accounted for 53.8% of all procedures, whilst the exposure of impacted teeth and soft tissue surgery represented 34.9% and 11.3% of procedures respectively. The median surgical time for techniques undertaken with sedation was 30.00 (inter-quartile range 25.00, 43.50) minutes whilst that for general anaesthetic was similar at 30.00 (inter-quartile range 15.25, 40.00) minutes (not statistically significant, (Mann Whitney U, W = 3081.5, P = 0.331). The majority of paediatric minor oral surgical procedures entail surgical exposure or removal of impacted teeth. The median treatment time for most procedures undertaken with either general anaesthetic or nitrous oxide sedation was 30 minutes.

  17. Fuel removal, transport, and storage

    International Nuclear Information System (INIS)

    Reno, H.W.

    1986-01-01

    The March 1979 accident at Unit 2 of the Three Mile Island Nuclear Power Station (TMI-2) which damaged the core of the reactor resulted in numerous scientific and technical challenges. Some of those challenges involve removing the core debris from the reactor, packaging it into canisters, loading canisters into a rail cask, and transporting the debris to the Idaho National Engineering Laboratory (INEL) for storage, examination, and preparation for final disposal. This paper highlights how some challenges were resolved, including lessons learned and benefits derived therefrom. Key to some success at TMI was designing, testing, fabricating, and licensing two rail casks, which each provide double containment of the damaged fuel. 10 refs., 12 figs

  18. Management of periodontally compromised mandibular molar with Hemisectioning: A case report

    Directory of Open Access Journals (Sweden)

    Bandu Napte

    2014-01-01

    Full Text Available Introduction: Hemisection involves sectioning of a periodontally involved mandibular molar so as to remove the involved root and save the remaining tooth. This procedure helps in saving a tooth which otherwise would have been deemed for extraction. Hemisection refers to removal or separation of root with its accompanying crown portion of two-rooted teeth, most commonly mandibular molars. Method: In this case report, an advanced Endo-Perio lesion on a left mandibular first molar was successfully treated by root-canal treatment and hemisection. This procedure helps preserve the tooth structure, alveolar bone and promote cost savings over other treatment options. Conclusion: Hemisection is a treatment option for saving a mandibular molar which is in advanced stage of periodontal disease of one root. Removal of the affected root will help in retaining the remaining tooth structure.

  19. The removal of a malpositioned implant in the anterior mandible using piezosurgery.

    Science.gov (United States)

    Marini, Ettore; Cisterna, Veronica; Messina, Antonello Maria

    2013-05-01

    In oral, cranio, and maxillofacial surgery, a close relationship among the bone, nerves, and blood vessels can be regularly observed. Surgical procedures for the removal of dental implants have the potential to cause vascular injury and bleeding in the floor of the mouth and internal anterior region of the mandible. Furthermore, conventional osteotomy techniques always require extensive protection of adjacent soft tissue because cutting is not limited to bone and could easily affect other tissues when applied improperly. We report the removal by means of piezosurgery of a malpositioned osseointegrated implant that had previously caused a sublingual hematoma during its insertion. The postoperative course was uneventful, no bleeding, infection, or hematoma formation was noted and the patient reported 100% resolution of all symptoms. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Armbrust, E.F.; Christy, V.W.; Doyle, J.R.; Kesinger, J.H.

    1977-03-01

    Sandia Laboratories Safe Operating Procedures (SOP) are written for activities which involve the use of explosives, dangerous chemicals, radioactive materials, hazardous systems, and certain types of operational facilities which present hazards. This guideline presents a suggested SOP format

  1. Model checking as an aid to procedure design

    International Nuclear Information System (INIS)

    Zhang, Wenhu

    2001-01-01

    The OECD Halden Reactor Project has been actively working on computer assisted operating procedures for many years. The objective of the research has been to provide computerised assistance for procedure design, verification and validation, implementation and maintenance. For the verification purpose, the application of formal methods has been considered in several reports. The recent formal verification activity conducted at the Halden Project is based on using model checking to the verification of procedures. This report presents verification approaches based on different model checking techniques and tools for the formalization and verification of operating procedures. Possible problems and relative merits of the different approaches are discussed. A case study of one of the approaches is presented to show the practical application of formal verification. Application of formal verification in the traditional procedure design process can reduce the human resources involved in reviews and simulations, and hence reduce the cost of verification and validation. A discussion of the integration of the formal verification with the traditional procedure design process is given at the end of this report. (Author)

  2. 75 FR 34064 - Manufactured Home Construction and Safety Standards, Test Procedures for Roof Trusses

    Science.gov (United States)

    2010-06-16

    ... failure. Failure is rupture, fracture, or excessive yielding. (v) Final recovery phase. Remove 2.0 times... members of the public. Commenters should follow the instructions provided on that site to submit comments... nondestructive testing procedure for roof trusses that permits a lower overall factor of safety to be used in...

  3. Procedural pain management in Italy: learning from a nationwide survey involving centers of the Italian Association of Pediatric Hematology-Oncology

    Directory of Open Access Journals (Sweden)

    Chiara Po'

    2011-12-01

    Full Text Available Procedural pain is an important aspect of care in pediatrics, and particularly in pediatric oncology where children often consider this to be the most painful experience during their illness. Best recommended practice to control procedural pain includes both sedative-analgesic administration and non-pharmacological treatments, practiced in an adequate and pleasant setting by skilled staff. A nationwide survey has been conducted among the Italian Centers of Pediatric Hematology-Oncology to register operators’ awareness on procedural pain, state of the art procedural pain management, operators’ opinions about pain control in their center, and possible barriers impeding sedation-analgesia administration. Based on indications in the literature, we discuss the results of the survey to highlight critical issues and suggest future directions for improvement. Future objectives will be to overcome differences depending on size, improve operators’ beliefs about the complexity of pain experience, and promote a global approach to procedural pain.

  4. PROGRAMMING OFFICE REMOVALS

    CERN Multimedia

    Groupe ST-HM

    2000-01-01

    The Removals Service recommends you to plan your removals well in advance, taking into account the fact that the Transport and Handling Group’s main priority remains the dismantling of LEP and the installation of the LHC. The requests can be made by: http://st.web.cern.ch/st/hm/removal/DEMEE.HTM Thank you for your cooperation.

  5. Comparison of percutaneous vertebroplasty with and without interventional tumor removal for spinal metastatic tumor without epidural involvement

    Directory of Open Access Journals (Sweden)

    Yan Su

    2017-03-01

    Conclusions: The combination of PVP+ITR is a safe and effective procedure, capable of providing significantly greater pain relief and vertebral stability than PVP alone in patients with malignant vertebral compression fractures.

  6. Modified Kidner procedure utilizing a Mitek bone anchor.

    Science.gov (United States)

    Dawson, D M; Julsrud, M E; Erdmann, B B; Jacobs, P M; Ringstrom, J B

    1998-01-01

    The recent development of small bone suture anchors has created several potential applications in reconstructive surgery of the foot. Mitek bone anchors are simple to insert, require less aggressive dissection and surgical time than reefing of the redundant posterior tibial tendon, and are a reliable method of tendon-to-bone fixation. Mitek bone anchors are an excellent technique for the treatment of redundant tibialis posterior tendon following a modified Kidner procedure. In modified Kidner procedures involving an excessively large os tibiale externum, Mitek anchoring of the redundant tibialis posterior tendon to the navicular bone is an excellent means for secure plication of the posterior tibial tendon in cases involving intraoperative tendon laxity. A description of the Mitek Anchor System and technique of application in a modified Kinder procedure is presented. The purpose of this study was to describe patient satisfaction and long-term clinical outcomes of the modified Kinder procedure with and without the Mitek bone anchoring system. A retrospective study of the modified Kinder procedure was performed with 13 patients being evaluated, seven with Mitek anchoring and six without. The University of Maryland 100-point Painful Foot Center Scoring System was modified to be more specific to the modified Kinder procedure for assessment of subjective long-term results. Patient overall satisfaction was rated good to excellent by 85.6% of patients in the Mitek group and by 100% of patients in the non-Mitek group. Use of the Mitek anchor allowed for quicker postoperative recovery to resumption of ambulation without assistive devices (average of 3 weeks vs. 4.42 weeks) and a quicker return to pain-free ambulation in normal shoegear (average of 4 weeks vs. 6 weeks). Mitek anchoring of the tibialis posterior tendon, theoretically, increases medial arch support as evidenced by 14% of the Mitek group and 67% of the non-Mitek group requiring postoperative orthotics.

  7. APE (state-oriented approach) centralized control procedures; Procedures de conduite APE (Approche Par Etats)

    Energy Technology Data Exchange (ETDEWEB)

    Astier, D. [FRAMATOME ANP, 92 - Paris-La-Defence (France); Depont, G. [Electricite de France (EDF/DPN), 93 - Saint-Denis (France); Van Dermarliere, Y. [Electricite de France (EDF/SEPTEN), 69 - Villeurbanne (France)

    2004-07-01

    This article presents the progressive implementation of the state-oriented approach (APE) for centralized control procedures in French nuclear power plants. The implementation began in the years 1982-83 and it concerned only the circuits involved in engineered safeguard systems such IS (safety injection), EAS (containment spray system) and GMPP (reactor coolant pump set). In 2003 the last PWR unit switched from the event oriented approach to APE for post-accidental situations.

  8. Endoscopic Transseptal Approach with Posterior Nasal Spine Removal: A Wide Surgical Corridor to the Craniovertebral Junction and Odontoid: Technical Note and Case Series.

    Science.gov (United States)

    Rossini, Zefferino; Milani, Davide; Nicolosi, Federico; Costa, Francesco; Lasio, Giovanni Battista; D'Angelo, Vincenzo Antonio; Fornari, Maurizio; Colombo, Giovanni

    2018-02-01

    The transnasal approach to lesions involving the craniovertebral junction represents a technical challenge because of limited inferior exposure. The endoscopic transseptal approach (EtsA) with posterior nasal spine (PNS) removal is described. This technique can create a wide exposure of the craniovertebral junction, thereby increasing the caudal exposure. On patients undergoing anterior craniovertebral junction decompression, we calculated the degree of exposure on the sagittal plan through a paraseptal route, an EtsA without and with PNS removal. The horizontal exposure and working area with the latter approach were also evaluated. Five patients underwent the transnasal procedure. The age of patients ranged from 34-71 years. All patients harbored basilar impression. The mean postoperative Nurick grade (1, 8) was improved versus the average preoperative grade (3). The average follow-up duration was 16 months. All patients underwent occipitocervical fixation. The mean vertical distances, from the clinoid recess to the inferior most limit with the paraseptal approach, EtsA without and with PNS removal were 38.52, 44.12, and 51.16 mm, respectively. The difference between our approach and a standard paraseptal route was statistically significant (P = 0.041; P< 0.05). The mean horizontal distances were 31.68 mm (mononostril entry) and 35.37 mm (binostril entry). The mean working area was 1795.53 mm 2 . Endoscopic endonasal approaches to the craniovertebral junction are increasing, but the downward extension on the anterior cervical spine represents a limit. Therefore, many surgeons prefer transoral or transcervical approaches. The EtsA with PNS removal allows for a more caudal exposure than the standard paraseptal approach, with reduced nasal trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Comparison of Emergency Medicine Malpractice Cases Involving Residents to Non-Resident Cases.

    Science.gov (United States)

    Gurley, Kiersten L; Grossman, Shamai A; Janes, Margaret; Yu-Moe, C Winnie; Song, Ellen; Tibbles, Carrie D; Shapiro, Nathan I; Rosen, Carlo L

    2018-04-17

    Data are lacking on how emergency medicine (EM) malpractice cases with resident involvement differs from cases that do not name a resident. To compare malpractice case characteristics in cases where a resident is involved (resident case) to cases that do not involve a resident (non-resident case) and to determine factors that contribute to malpractice cases utilizing EM as a model for malpractice claims across other medical specialties. We used data from the Controlled Risk Insurance Company (CRICO) Strategies' division Comparative Benchmarking System (CBS) to analyze open and closed EM cases asserted from 2009-2013. The CBS database is a national repository that contains professional liability data on > 400 hospitals and > 165,000 physicians, representing over 30% of all malpractice cases in the U.S (> 350,000 claims). We compared cases naming residents (either alone or in combination with an attending) to those that did not involve a resident (non-resident cohort). We reported the case statistics, allegation categories, severity scores, procedural data, final diagnoses and contributing factors. Fisher's exact test or t-test was used for comparisons (alpha set at 0.05). Eight hundred and forty-five EM cases were identified of which 732 (87%) did not name a resident (non-resident cases), while 113 (13%) included a resident (resident cases) (Figure 1). There were higher total incurred losses for non-resident cases (Table 1). The most frequent allegation categories in both cohorts were "Failure or Delay in Diagnosis/Misdiagnosis" and "Medical Treatment" (non-surgical procedures or treatment regimens i.e. central line placement). Allegation categories of Safety and Security, Patient Monitoring, Hospital Policy and Procedure and Breach of Confidentiality were found in the non-resident cases. Resident cases incurred lower payments on average ($51,163 vs. $156,212 per case). Sixty six percent (75) of resident vs 57% (415) of non-resident cases were high severity claims

  10. Fabrication of Biomembrane from Banana Stem for Lead Removal

    Directory of Open Access Journals (Sweden)

    Afianti Sulastri

    2016-04-01

    Full Text Available Heavy metal (i.e. lead (Pb is one of the environmental issues recently due to its danger for human health. Therefore, strategy for removing Pb from waste water treatment is important. One of the prospective methods to remove Pb is membrane biofilter. Here, the purpose of this study was to prepare the membrane biofilter for Pb removal process. In this study, membrane biofilter was produced from banana stem. Banana stem was selected because of its abundant availability   in Indonesia. And, for somewhat, this banana stem can be environmental problems (become waste since Indonesia is one of the top producers in the world. In short of the experimental procedure, we conducted three steps of experiments: (1 Preparation of microbial cellulose using Acetobacter xylinum using banana stem for a main source; (2 Synthesis of cellulose acetate; and (3 Preparation of biomembrane from obtained cellulose acetate. To produce membrane biofilter, the cellulose acetate was dissolved into dichloromethane to form a dope solution. Then, the doped solution was printed in Petri dish. Some biomembrane properties were characterized for identification, i.e. infrared spectra, electron microscope, and elemental analysis. Experimental results showed that we succeeded to prepare biomembrane with a pore size of 5 μm. The filtration efficiency of our prepared membrane was 93.7% of Pb when using Pb with a concentration of 10 ppm.

  11. Removal of pharmaceuticals and personal care products in aquatic plant-based systems: A review

    International Nuclear Information System (INIS)

    Zhang, Dongqing; Gersberg, Richard M.; Ng, Wun Jern; Tan, Soon Keat

    2014-01-01

    Pharmaceuticals and personal care products (PPCPs) in the aquatic environment are regarded as emerging contaminants and have attracted increasing concern. The use of aquatic plant-based systems such as constructed wetlands (CWs) for treatment of conventional pollutants has been well documented. However, available research studies on aquatic plant-based systems for PPCP removal are still limited. The removal of PPCPs in CWs often involves a diverse and complex set of physical, chemical and biological processes, which can be affected by the design and operational parameters selected for treatment. This review summarizes the PPCP removal performance in different aquatic plant-based systems. We also review the recent progress made towards a better understanding of the various mechanisms and pathways of PPCP attenuation during such phytoremediation. Additionally, the effect of key CW design characteristics and their interaction with the physico-chemical parameters that may influence the removal of PPCPs in functioning aquatic plant-based systems is discussed. -- Highlights: • Investigation of the removal performance of PPCPs in CW systems. • Investigation of the mechanisms and pathways contributing to PPCP removal in CWs. • Investigation of the effect of CW design parameters on PPCP removal. • Investigation of the correlation between physico-chemical parameters and PPCP removal. -- This review gives an overview of the present state of research on the removal of pharmaceutical and personal care products by means of constructed wetlands

  12. United Kingdom procedures in case of nuclear accidents

    International Nuclear Information System (INIS)

    Chalfont, L.

    1988-01-01

    From the United Kingdom experience, general principles for establishing emergency plans are drawn. Every country with nuclear plant should have such emergency arrangements capable of dealing with the largest scale that can be envisaged as a practical possibility. While the effects of accidents cannot be anticipated in detail these plans should form a good flexible basis for providing the resources, communications and procedures that are likely to be needed. They encompass the administrative infrastructure of the area surrounding the nuclear installation and involve co-ordination with the police, fire services and ambulance services, the local and county authorities, the authorities responsible for food, agriculture, fisheries and water, and the health authorities including hospitals and medical services. Special training and procedures have to be established for the personnel that are involved and exercises graduating from the exercising of special procedures to large scale simulated accidents need to be carried out periodically. Good communication systems have to be established between the nuclear installations, the operational support centres or equivalent, the field and headquarters units of the relevant organizations, and the central government departments so that whatever additional resources and support are needed can be marshalled quickly and efficiently. (author)

  13. Removal of Heavy Metals and PAH in Highway Detention Ponds

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby; Larsen, Torben; Thorndahl, Søren Liedtke

    2005-01-01

    , which has been designed according to standard design criteria for several decades. The study will focus on heavy metals (Cd, Cr, Cu, Pb and Zn) and polyaromatic hydrocarbons (PAH). The long-term simulation of input of flow and pollution to the ponds will be a hind cast based on time series of historical......The paper presents some of the first results from a study of the removal of pollutants in highway detention ponds in Denmark. The objective of the study is to set up a procedure for long-term modelling of discharges of pollutants to the environment from the many Danish highway detention ponds...... rainfalls. The modelling will take place in a special version of the MIKE URBAN. The modelling is calibrated and validated on measurements from selected highway catchments. The removal of pollutants in the ponds is studied by local measurements in combination with CFD modelling using the MIKE 21 and MIKE 3...

  14. Removing method for radon gas exhausted from nuclear fuel material

    International Nuclear Information System (INIS)

    Kato, Kenji.

    1993-01-01

    A centrifugal separator is disposed in the midway of an exhaustion pipe of a nuclear fuel handling facility, and exhausted gases are sent into a rotational cylinder of the separator. Radon gases in the midway of exhaustion are separated from the exhaustion gases by the centrifugal force of the separator and caused to stagnate at the periphery of the circumferential wall of the rotational cylinder. At the same time, the exhaustion gases having the radon gases separated therefrom are exhausted from the periphery of a rotational shaft of the rotational cylinder. Then, the radon gases stagnated in the rotational cylinder are decayed depending on the half-decay time. With such procedures, the radon gases can be removed continuously without discharging them to the outside. Further, it is preferred that an exhaustion blower or the like for putting the inside of the nuclear fuel handing facility to a negative pressure is disposed as in a conventional case. Further, a plurality of centrifugal separators may be disposed to exhaustion pipes, to remove radon gases in the exhaust gases by a multi stage way. Radon gases can be removed in a saved space with no requirement for exchange of adsorbents or temperature control. (T.M.)

  15. Effective removal of Ni(II) from aqueous solutions by modification of nano particles of clinoptilolite with dimethylglyoxime.

    Science.gov (United States)

    Nezamzadeh-Ejhieh, Alireza; Kabiri-Samani, Mehdi

    2013-09-15

    In this work an Iranian natural clinoptilolite tuff was pre-treated and changed to the micro (MCP) and nano (NCP) particles by mechanical method. Modification of micro and nano particles and also their Ni-exchanged forms were done by dimethylglyoxime (DMG). The raw and modified samples were characterized by XRD, FT-IR, SEM, BET, TG-DTG and energy dispersive analysis X-ray spectroscopy (EDAX). Removal of Ni(II) by modified and unmodified samples was investigated in batch procedure. It was found that NCP-DMG has higher capacity for removal of Ni(II). The effects of analytical parameters such as pH, dose of DMG, concentration of nickel solution, contact time and selectivity were studied and the optimal operation parameters were found as follows: pHPZC: 7.6, CNi(II): 0.01 M, contact time: 360 min and DMG dosage: 5mM. The results of selectivity experiments showed that the modified zeolite has a good selectivity for nickel in the presence of different multivalent cations. Langmuir and Freundlich isotherm models were adopted to describe the adsorption isotherms. Adsorption isotherms of Ni(II) ions could be best modelled by Langmuir equation, that indicate the monolayer sorption of Ni(II). Comparison of two kinetic models indicates that the adsorption kinetic can be well described by the pseudo-second-order rate equation that indicates that the rate limiting step for the process involves chemical reaction. The negative ΔH and ΔG indicate an exothermic and spontaneously process. The negative ΔS indicates that the adsorption of nickel cations from solution occurs with lower amount ion replacement, thus chemisorptions due to complex formation are dominant process in nickel removal. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. An operational protocol for facilitating start-up of single-stage autotrophic nitrogen-removing reactors based on process stoichiometry

    DEFF Research Database (Denmark)

    Mutlu, Ayten Gizem; Vangsgaard, Anna Katrine; Sin, Gürkan

    2013-01-01

    Start-up and operation of single-stage nitritation–anammox sequencing batch reactors (SBRs) for completely autotrophic nitrogen removal can be challenging and far from trivial. In this study, a step-wise procedure is developed based on stoichiometric analysis of the process performance from...

  17. INADMISSIBLE EVIDENCE IN CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Mihajlo Dika

    2016-01-01

    Full Text Available This paper examines the exclusion of specific means of evidence as instruments for determining the object of evidence, as well as the taking of evidence in the framework of the Croatian civil procedure law. The introduction lays the grounds for classifying and qualifying exclusion of evidence (general, special; absolute, relative; removable, irremovable; direct, indirect, after which greater attention is paid to the so called absolute and relative type; exclusionary evidence of the direct relative type pertaining to the establishing of facts, and evidence dismissals. With regard to the indirect relative type, the paper examines exclusionary evidence concerning the object of evidence. The remainder of the paper focuses on illegally obtained evidence, while outlining the constitutional, statutory, judicature and doctrinaire premises of bearing for such evidence. Subsequently, the question of evidence obtained in violation of the Constitutional guarantee of respect and legal protection of private and family life, dignity, reputation and honour, as well as evidence obtained by breach of the Constitutional guarantee of freedom and secrecy of correspondence and all other forms of communication, and in violation of the right to safety and privacy of personal data, are discussed too. In addition, the paper analyses the institutions of preclusion of evidence and the so called informative evidence. Concluding, the author points to a lacking regulation of inadmissible evidence within the Croatian civil procedure law, underlining the need to determine de lege ferenda legal requirements with a view to operationalizing inadmissible evidence within the Croatian civil procedure law.

  18. ARSENIC REMOVAL FROM DRINKING WATER BY IRON REMOVAL PLANTS

    Science.gov (United States)

    This report documents a long term performance study of two iron removal water treatment plants to remove arsenic from drinking water sources. Performance information was collected from one system located in midwest for one full year and at the second system located in the farwest...

  19. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized

  20. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized