WorldWideScience

Sample records for previously reported electron

  1. [Electronic cigarettes - effects on health. Previous reports].

    Science.gov (United States)

    Napierała, Marta; Kulza, Maksymilian; Wachowiak, Anna; Jabłecka, Katarzyna; Florek, Ewa

    2014-01-01

    Currently very popular in the market of tobacco products have gained electronic cigarettes (ang. E-cigarettes). These products are considered to be potentially less harmful in compared to traditional tobacco products. However, current reports indicate that the statements of the producers regarding to the composition of the e- liquids not always are sufficient, and consumers often do not have reliable information on the quality of the product used by them. This paper contain a review of previous reports on the composition of e-cigarettes and their impact on health. Most of the observed health effects was related to symptoms of the respiratory tract, mouth, throat, neurological complications and sensory organs. Particularly hazardous effects of the e-cigarettes were: pneumonia, congestive heart failure, confusion, convulsions, hypotension, aspiration pneumonia, face second-degree burns, blindness, chest pain and rapid heartbeat. In the literature there is no information relating to passive exposure by the aerosols released during e-cigarette smoking. Furthermore, the information regarding to the use of these products in the long term are not also available.

  2. Case report of electronic cigarettes possibly associated with eosinophilic pneumonitis in a previously healthy active-duty sailor.

    Science.gov (United States)

    Thota, Darshan; Latham, Emi

    2014-07-01

    Electronic cigarettes (e-cigarettes) are a technology that has been touted as a safe and effective alternative to traditional cigarettes. There is, however, a paucity of literature showing the adverse outcomes of e-cigarettes and a correlation with acute eosinophilic pneumonia (AEP). To present a possible association between e-cigarettes and AEP. A 20-year-old previously healthy man was found to develop AEP after smoking an e-cigarette. He was treated with antibiotics and steroids and his symptoms improved. Though an alternative to traditional cigarettes, e-cigarettes can have unpredictable and potentially serious adverse effects. More research needs to be conducted to determine their safety. If seeing a patient in the ED with pulmonary symptoms after use of e-cigarettes, AEP should be considered in the differential. Published by Elsevier Inc.

  3. Urethrotomy has a much lower success rate than previously reported.

    Science.gov (United States)

    Santucci, Richard; Eisenberg, Lauren

    2010-05-01

    We evaluated the success rate of direct vision internal urethrotomy as a treatment for simple male urethral strictures. A retrospective chart review was performed on 136 patients who underwent urethrotomy from January 1994 through March 2009. The Kaplan-Meier method was used to analyze stricture-free probability after the first, second, third, fourth and fifth urethrotomy. Patients with complex strictures (36) were excluded from the study for reasons including previous urethroplasty, neophallus or previous radiation, and 24 patients were lost to followup. Data were available for 76 patients. The stricture-free rate after the first urethrotomy was 8% with a median time to recurrence of 7 months. For the second urethrotomy stricture-free rate was 6% with a median time to recurrence of 9 months. For the third urethrotomy stricture-free rate was 9% with a median time to recurrence of 3 months. For procedures 4 and 5 stricture-free rate was 0% with a median time to recurrence of 20 and 8 months, respectively. Urethrotomy is a popular treatment for male urethral strictures. However, the performance characteristics are poor. Success rates were no higher than 9% in this series for first or subsequent urethrotomy during the observation period. Most of the patients in this series will be expected to experience failure with longer followup and the expected long-term success rate from any (1 through 5) urethrotomy approach is 0%. Urethrotomy should be considered a temporizing measure until definitive curative reconstruction can be planned. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Electronics Industry Study Report

    National Research Council Canada - National Science Library

    Belt, David; Fellows, John R; Kameru, Philip; Nazaroff, Boris-Frank A; Pauroso, Anthony; Schulz, Frederick; Ballew, Bob; Bond, Thomas; Demers, Stephy; Kirkpatrick, Steve

    2005-01-01

    This paper provides a national strategy for the US electronics industry. Electronics is one of the largest industries in the US and plays a critical role in almost every aspect of national security...

  5. Consumer reports [electronic resource

    National Research Council Canada - National Science Library

    1942-01-01

    ... only. A limited number of selected reports, advice on product selection and safety alerts are freely available, as are a five year listing of product recalls, a listing of major consumer product...

  6. Electronics Department. Progress Report 1984

    DEFF Research Database (Denmark)

    Risø National Laboratory, Roskilde

    This report summarizes the activities in the Electronics Department in 1984. These include work under the headings of informatics, applied laser physics, nuclear geophysics, instrumentation and measuring techniques, and instrumentation consulting, registration and maintenance for the Danish...

  7. Vessel Electronic Reporting System (VERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The VERS system is composed of a database and other related applications which facilitate the reporting of electronically collected research data via Fisheries...

  8. Electronics Department progress report 1984

    International Nuclear Information System (INIS)

    1985-11-01

    This report summarizes the activities in the Electronics Department in 1984. These include work under the headings of informatics, applied laser physics, nuclear geophysics, instrumentation and measuring techniques, and instrumentation consulting, registration and maintenance for the Danish Research Council and Risoe National Laboratory. (author)

  9. Electronics Department progress report 1983

    International Nuclear Information System (INIS)

    1984-05-01

    this report summarizes the Electronics Department's activities in 1983. These include work under the headings of man-machine system and operator studies, reliability techniques, application of nuclear techniques to mineral exploration, applied laser physics, computing and, lastly, research instrumentation. (author)

  10. Logic of Accounting: The Case of Reporting Previous Options in Norwegian Activation Encounters

    Science.gov (United States)

    Solberg, Janne

    2017-01-01

    The article deals with the enactment of client resistance in Norwegian vocational rehabilitation encounters. More specific, a practice here called "reporting previous options" is analyzed by using the resources of ethnomethodological conversation analysis (CA) in five instances as doing some sort of accounting. In response to the…

  11. Availability of nuclear decay data in electronic form, including beta spectra not previously published

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.; Cristy, M.

    1994-01-01

    The unabridged data used in preparing ICRP Publication 38 (1983) and a monograph of the Medical Internal Radiation Dose (MIRD) Committee are now available in electronic form. The open-quotes ICRP38 collectionclose quotes contains data on the energies and intensities of radiations emitted by 825 radionuclides (those in ICRP Publication 38 plus 13 from the MIRD monograph), and the open-quotes MIRD collectionclose quotes contains data on 242 radionuclides. Each collection consists of a radiations data file and a beta spectra data file. The radiations data file contains the complete listing of the emitted radiations, their types, mean or unique energies, and absolute intensities for each radionuclide, the probability that a beta particle will be emitted with kinetic energies defined by a standard energy grid. Although summary information from the radiation data files has been published, neither the unabridged data nor the beta spectra have been published. These data files and a data extraction utility, which runs on a personal computer, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory. 13 refs., 1 fig., 6 tabs

  12. Erysipelothrix endocarditis with previous cutaneous lesion: report of a case and review of the literature

    Directory of Open Access Journals (Sweden)

    Marion P. Rocha

    1989-08-01

    Full Text Available This report describes the first documented case of Erysipelothrix rhusiopathiae endocarditis in Latin America. The patient was a 51-years-old male, moderate alcoholic, with a previous history of aortic failure. He was used to fishing and cooking as a hobby and had his left hand wounded by a fish-bone. The disease began with erysipeloid form and developed to septicemia and endocarditis. He was treated with antibiotics and surgery for aortic valve replacement. There are only 46 cases of E. rhusiopathiae endocarditis reported to date. The authors wonder if several other cases might go unreported for lack of microbiological laboratorial diagnosis.

  13. Granulomatous lobular mastitis: report of a case with previously undescribed histopathological abnormalities.

    Science.gov (United States)

    Axelsen, R A; Reasbeck, P

    1988-10-01

    A 41-yr-old multiparous woman presented with a discrete breast lump which proved histologically to be an example of granulomatous lobular mastitis. The clinical and histological features were similar to those noted in previous reports. Additional histological features in the present case were an intense mononuclear cell infiltration of lobular and ductal epithelium, associated with nuclear fragments morphologically suggestive of apoptosis. These appearances, which have not previously been described, are illustrated, together with the more classical features of the condition well demonstrated by the present case. The novel histological features noted here suggest that the development of granulomatous lobular mastitis may be at least in part immunologically mediated, and that the cellular infiltrates seen may be a manifestation of cell-mediated destruction of mammary epithelium.

  14. Eikenella corrodens endocarditis and liver abscess in a previously healthy male, a case report

    DEFF Research Database (Denmark)

    Nordholm, Anne Christine; Vøgg, Ruth Ottilia Birgitta; Permin, Henrik

    2018-01-01

    BACKGROUND: Eikenella corrodens is one of the HACEK bacteria constituting part of the normal flora of the oropharynx, however, still an uncommon pathogen. We report a case of a large Eikenella corrodens liver abscess with simultaneously endocarditis in a previously healthy male. CASE PRESENTATION...... on pneumonia treatment, a PET-CT scan was performed, which showed a large multiloculated abscess in the liver. The abscess was drained using ultrasound guidance. Culture demonstrated Eikenella corrodens. Transesophageal echocardiography revealed aortic endocarditis. The patient was treated with antibiotics...... corrodens concurrent liver abscess and endocarditis. The case report highlights that Eikenella corrodens should be considered as a cause of liver abscess. Empirical treatment of pyogenic liver abscess will most often cover Eikenella corrodens, but the recommended treatment is a third generation...

  15. Yearly (Fiscal) Historical Electronic Services Report

    Data.gov (United States)

    Social Security Administration — This report contains yearly electronic services data for online applications. This report is updated monthly for the current fiscal year. The report is divided into...

  16. A previously unreported variant of the synostotic sagittal suture: Case report and review of salient literature

    Directory of Open Access Journals (Sweden)

    Madison Budinich

    2016-12-01

    Full Text Available Introduction: Sagittal synostosis is a rare congenital disease caused by the premature fusion of the sagittal suture. Craniosynostosis occurs for a variety of reasons, different for every case, and often the etiology is unclear but the anomaly can frequently be seen as part of Crouzon's or Apert's syndromes. Herein, we discuss a rare case of craniosynostosis where the patient presented with a, to our knowledge, a previously undescribed variant of sagittal synostosis. Case report: A 3-month-old female infant presented to a craniofacial clinic for a consultation regarding an abnormal head shape. Images of the skull were performed, demonstrating that the patient had craniosynostosis. The patient displayed no other significant symptoms besides abnormalities in head shape. The sagittal suture was found to extend into the occipital bone where it was synostotic. Conclusion: To our knowledge, a synostotic sagittal suture has not been reported that extended posteriorly it involve the occipital bone. Those who interpret imaging or operate on this part of the skull should consider such a variation. Keywords: Anatomy, Craniosynostosis, Skull, Malformation, Pediatrics

  17. Adenylosuccinate lyase (ADSL) and infantile autism: Absence of previously reported point mutation

    Energy Technology Data Exchange (ETDEWEB)

    Fon, E.A.; Sarrazin, J.; Rouleau, G.A. [Montreal General Hospital (Canada)] [and others

    1995-12-18

    Autism is a heterogeneous neuropsychiatric syndrome of unknown etiology. There is evidence that a deficiency in the enzyme adenylosuccinate lyase (ADSL), essential for de novo purine biosynthesis, could be involved in the pathogenesis of certain cases. A point mutation in the ADSL gene, resulting in a predicted serine-to-proline substitution and conferring structural instability to the mutant enzyme, has been reported previously in 3 affected siblings. In order to determine the prevalence of the mutation, we PCR-amplified the exon spanning the site of this mutation from the genomic DNA of patients fulfilling DSM-III-R criteria for autistic disorder. None of the 119 patients tested were found to have this mutation. Furthermore, on preliminary screening using single-strand conformation polymorphism (SSCP), no novel mutations were detected in the coding sequence of four ADSL exons, spanning approximately 50% of the cDNA. In light of these findings, it appears that mutations in the ADSL gene represent a distinctly uncommon cause of autism. 12 refs., 2 figs.

  18. NASAwide electronic publishing system: Electronic printing and duplicating, stage-2 evaluation report (GSFC)

    Science.gov (United States)

    Tuey, Richard C.; Lane, Robert; Hart, Susan V.

    1995-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).

  19. Electronic Reporting of Air Emissions

    Science.gov (United States)

    EPA regulations require affected sources to perform emissions source tests, conduct continuous emissions monitoring, and submit compliance and emissions reports. This site provides technical resources and access for providing such submissions.

  20. Northeast Electronic Reporting System (NERS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NOAA/NEFSC Study fleets are a subset of fishing vessels from which high quality, self-reported data on fishing effort, area fished, gear characteristics, catch,...

  1. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  2. Self-reported previous knee injury and low knee function increase knee injury risk in adolescent female football.

    Science.gov (United States)

    Clausen, M B; Tang, L; Zebis, M K; Krustrup, P; Hölmich, P; Wedderkopp, N; Andersen, L L; Christensen, K B; Møller, M; Thorborg, K

    2016-08-01

    Knee injuries are common in adolescent female football. Self-reported previous knee injury and low Knee injury and Osteoarthritis Outcome Score (KOOS) are proposed to predict future knee injuries, but evidence regarding this in adolescent female football is scarce. The aim of this study was to investigate self-reported previous knee injury and low KOOS subscale score as risk factors for future knee injuries in adolescent female football. A sample of 326 adolescent female football players, aged 15-18, without knee injury at baseline, were included. Data on self-reported previous knee injury and KOOS questionnaires were collected at baseline. Time-loss knee injuries and football exposures were reported weekly by answers to standardized text-message questions, followed by injury telephone interviews. A priori, self-reported previous knee injury and low KOOS subscale scores (female football. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. A case report: mixed thrombus formation in a previously sutured right atrium.

    Science.gov (United States)

    Yunfei, Ling; Dongxu, Li; Shuhua, Luo; Yabo, Wang; San, Deep; Changping, Gan; Ke, Lin; Qi, An

    2014-08-01

    We describe the case of a 19-year-old Chinese woman who nine months prior underwent repair of an atrial septal defect and came to our hospital with a right atrial mass attached to the anterior wall of the right atrium on transthoracic echocardiography. Pathologic examination revealed the mass was a mixed-type thrombosis with some unusual organization, which previously was not described in literature.

  4. Health effects of low-level radiation in shipyard workers: report of previous work

    International Nuclear Information System (INIS)

    Matanoski, G.M.

    1984-01-01

    Progress over the course of the Nuclear Shipyard Workers Study is reported. The derivation of the study population, the gathering of health histories, the US Navy radiation protection program, and the determination of radiation exposures is described

  5. Absence of psilocybin in species of fungi previously reported to contain psilocybin and related tryptamine derivatives

    OpenAIRE

    Stijve, T.; Kuyper, Th.W.

    1988-01-01

    Seven taxa of agarics reported in literature to contain psilocybin (viz. Psathyrella candolleana, Gymnopilus spectabilis, G. fulgens, Hygrocybe psittacina var. psittacina and var. californica, Rickenella fibula, R. swartzii) have been analysed for psilocybin and related tryptamines with negative results.

  6. Absence of psilocybin in species of fungi previously reported to contain psilocybin and related tryptamine derivatives

    NARCIS (Netherlands)

    Stijve, T.; Kuyper, Th.W.

    1988-01-01

    Seven taxa of agarics reported in literature to contain psilocybin (viz. Psathyrella candolleana, Gymnopilus spectabilis, G. fulgens, Hygrocybe psittacina var. psittacina and var. californica, Rickenella fibula, R. swartzii) have been analysed for psilocybin and related tryptamines with negative

  7. Groin Problems in Male Soccer Players Are More Common Than Previously Reported

    DEFF Research Database (Denmark)

    Harøy, Joar; Clarsen, Ben; Thorborg, Kristian

    2017-01-01

    surveillance method developed to capture acute and overuse problems. STUDY DESIGN: Descriptive epidemiology study. METHODS: We registered groin problems during a 6-week period of match congestion using the Oslo Sports Trauma Research Center Overuse Injury Questionnaire. A total of 240 players from 15 teams......BACKGROUND: The majority of surveillance studies in soccer have used a time-loss injury definition, and many groin problems result from overuse, leading to gradually increasing pain and/or reduced performance without necessarily causing an absence from soccer training or match play. Thus......, the magnitude of groin problems in soccer has probably been underestimated in previous studies based on traditional injury surveillance methods. PURPOSE: To investigate the prevalence of groin problems among soccer players of both sexes and among male soccer players at different levels of play through a new...

  8. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    Science.gov (United States)

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  9. [Lessons from abroad. Current and previous crisis in other countries. SESPAS report 2014].

    Science.gov (United States)

    Rivadeneyra-Sicilia, Ana; Minué Lorenzo, Sergio; Artundo Purroy, Carlos; Márquez Calderón, Soledad

    2014-06-01

    The evidence available on the impact of previous crises on health reveals different patterns attributable to study designs, the characteristics of each crisis, and other factors related to the socioeconomic and political context. There is greater consensus on the mediating role of government policy responses to financial crises. These responses may magnify or mitigate the adverse effects of crises on population health. Some studies have shown a significant deterioration in some health indicators in the context of the current crisis, mainly in relation to mental health and communicable diseases. Alcohol and tobacco use have also declined in some European countries. In addition, this crisis is being used by some governments to push reforms aimed at privatizing health services, thereby restricting the right to health and healthcare. Specifically, action is being taken on the three axes that determine health system financing: the population covered, the scope of services, and the share of the costs covered. These measures are often arbitrarily implemented based on ideological decisions rather than on the available evidence and therefore adverse consequences are to be expected in terms of financial protection, efficiency, and equity. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  10. Increased Symptom Reporting in Young Athletes Based on History of Previous Concussions.

    Science.gov (United States)

    Moser, Rosemarie Scolaro; Schatz, Philip

    2017-01-01

    Research documents increased symptoms in adolescents with a history of two or more concussions. This study examined baseline evaluations of 2,526 younger athletes, ages 10 to 14. Between-groups analyses examined Post Concussion Symptom Scale symptoms by concussion history group (None, One, Two+) and clusters of Physical, Cognitive, Emotional, and Sleep symptoms. Healthy younger athletes with a concussion history reported greater physical, emotional, and sleep-related symptoms than those with no history of concussion, with a greater endorsement in physical/sleep symptom clusters. Findings suggest younger athletes with a history of multiple concussions may experience residual symptoms.

  11. Leiomyosarcoma of the Prostate: Case Report and Review of 54 Previously Published Cases

    Directory of Open Access Journals (Sweden)

    Gerasimos P. Vandoros

    2008-01-01

    Full Text Available Prostate leiomyosarcoma is an extremely rare and highly aggressive neoplasm that accounts for less than 0.1% of primary prostate malignancies. We present a patient with primary leiomyosarcoma of the prostate and review 54 cases reported in the literature to discuss the clinical, diagnostic and therapeutic aspects of this uncommon tumor. Median survival was estimated at 17 months (95% C.I. 20.7–43.7 months and the 1-, 3-, and 5-year actuarial survival rates were 68%, 34%, and 26%, respectively. The only factors predictive of long-term survival were negative surgical margins and absence of metastatic disease at presentation. A multidisciplinary approach is necessary for appropriate management of this dire entity.

  12. Ruptured Rudimentary Horn Pregnancy at 25 Weeks with Previous Vaginal Delivery: A Case Report

    Directory of Open Access Journals (Sweden)

    Deepa V. Kanagal

    2012-01-01

    Full Text Available Unicornuate uterus with rudimentary horn occurs due to failure of complete development of one of the Mullerian ducts and incomplete fusion with the contralateral side. Pregnancy in a noncommunicating rudimentary horn is extremely rare and usually terminates in rupture during first or second trimester of pregnancy. Diagnosis of rudimentary horn pregnancy and its rupture in a woman with prior vaginal delivery is difficult. It can be missed in routine ultrasound scan and in majority of cases it is detected after rupture. It requires a high index of suspicion. We report a case of G2PlL1 with rupture rudimentary horn pregnancy at 25 weeks of gestation which was misdiagnosed as intrauterine pregnancy with fetal demise by ultrasound, and termination was attempted and the case was later referred to our hospital after the patient developed hemoperitoneum and shock with a diagnosis of rupture uterus. Laparotomy revealed rupture of right rudimentary horn pregnancy with massive hemoperitoneum. Timely laparotomy, excision of the horn, and blood transfusion saved the patient.

  13. Stevens-Johnson Syndrome Induced by Carbamazepine Treatment in a Patient Who Previously Had Carbamazepine Induced Pruritus - A Case Report -

    OpenAIRE

    Bae, Hyun Min; Park, Yoo Jung; Kim, Young Hoon; Moon, Dong Eon

    2013-01-01

    Stevens-Johnson syndrome (SJS) is a rare but life-threatening skin reaction disease and carbamazepine is one of its most common causes. We report a case of SJS secondary to carbamazepine in a patient with previous pruritus due to carbamazepine which was given for treatment of trigeminal neuralgia. We would like to caution all providers that carbamazepine readministration should be avoided in the patient with a previous history of SJS or adverse skin reaction. In addition, we strongly recommen...

  14. Electronic probe microanalyzer. Annual report 1963

    International Nuclear Information System (INIS)

    Kirianenko, Alexis; Maurice, Francoise; Seguin, Remy; Zemskoff, Anne; Adda, Yves

    1964-09-01

    This annual report presents the highlights of the fifth year of operation of the CEA Saclay's electronic probe microanalyzer. It provides a list of the analyses performed during the year with some illustrations and mentions the improvements given to the apparatus and its new analysing possibilities (crystallographic analysis using divergent X beams, 'electronic' image formation with respect to the atomic number). Highlights in the development of this analytical technique are presented as well as a new device designed by R. Castaing: the secondary ion emission microanalyser. A list of all laboratories equipped with the French microanalyser is provided

  15. Self-reported previous knee injury and low knee function increase knee injury risk in adolescent female football

    DEFF Research Database (Denmark)

    Clausen, Mikkel Bek; Tang, L; Zebis, M K

    2016-01-01

    with low KOOS subscale scores (Sport/Recreational (RR: 2.2) and Quality of Life (RR: 3.0) (P time-loss knee...... questionnaires were collected at baseline. Time-loss knee injuries and football exposures were reported weekly by answers to standardized text-message questions, followed by injury telephone interviews. A priori, self-reported previous knee injury and low KOOS subscale scores (... as independent variables in the risk factor analyses. The study showed that self-reported previous knee injury significantly increased the risk of time-loss knee injury [relative risk (RR): 3.65, 95% confidence (CI) 1.73-7.68; P time-loss knee injury was also significantly increased in players...

  16. Electronics Engineering Research. Final report, FY 1979

    International Nuclear Information System (INIS)

    Weissenberger, S.

    1980-01-01

    Accomplishments in Electronics Engineering Research (EER) during FY79 spanned a broad range of technologies, from high-speed microelectronics to digital image enhancement; from underground probing with electromagnetic waves to detecting neutrons with a small solid-state device; and from computer systems to aid engineers, to software tools to aid programmers. This report describes the overall EER program and its objectives, summarizes progress made in FY79, and outlines plans for FY80

  17. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  18. Electron-beam-fusion progress report, 1975

    International Nuclear Information System (INIS)

    1976-06-01

    Summaries of research work are given on electron sources, insulation problems, and power supplies. Some theoretical work is reported on fusion target design, self-consistent deposition and hydrodynamic calculations, analysis of x-ray pinhole data, diode code calculations, magnetically insulated diodes and transmission lines, ion sheath motion in plasma-filled diodes, relativistic distribution functions, macroscopic properties, and kinetic theory, heavy ion pulsed fusion, and collective ion acceleration. Some experimental work on targets, diode physics, and diagnostic developments is given

  19. Lack of Cetuximab induced skin toxicity in a previously irradiated field: case report and review of the literature

    Science.gov (United States)

    2010-01-01

    Introduction Mutation, amplification or dysregulation of the EGFR family leads to uncontrolled division and predisposes to cancer. Inhibiting the EGFR represents a form of targeted cancer therapy. Case report We report the case of 79 year old gentlemen with a history of skin cancer involving the left ear who had radiation and surgical excision. He had presented with recurrent lymph node in the left upper neck. We treated him with radiation therapy concurrently with Cetuximab. He developed a skin rash over the face and neck area two weeks after starting Cetuximab, which however spared the previously irradiated area. Conclusion The etiology underlying the sparing of the previously irradiated skin maybe due to either decrease in the population of EGFR expressing cells or decrease in the EGFR expression. We raised the question that "Is it justifiable to use EGFR inhibitors for patients having recurrence in the previously irradiated field?" We may need further research to answer this question which may guide the physicians in choosing appropriate drug in this scenario. PMID:20478052

  20. 78 FR 52860 - Electronic Reporting of Toxics Release Inventory Data

    Science.gov (United States)

    2013-08-27

    ... only exception to this electronic reporting requirement is for the few facilities that submit trade... rulemaking process later to require the electronic reporting of trade secrets. The EPA recognizes the... Electronic Reporting of Toxics Release Inventory Data AGENCY: Environmental Protection Agency (EPA). ACTION...

  1. An examination of safety reports involving electronic flight bags and portable electronic devices

    Science.gov (United States)

    2014-06-01

    The purpose of this research was to develop a better understanding of safety considerations with the use of Electronic Flight Bags (EFBs) and Portable Electronic Devices (PEDs) by examining safety reports from Aviation Safety Reporting System (ASRS),...

  2. Shunt malfunction causing acute neurological deterioration in 2 patients with previously asymptomatic Chiari malformation Type I. Report of two cases.

    Science.gov (United States)

    Elliott, Robert; Kalhorn, Stephen; Pacione, Donato; Weiner, Howard; Wisoff, Jeffrey; Harter, David

    2009-08-01

    Patients with symptomatic Chiari malformation Type I (CM-I) typically exhibit a chronic, slowly progressive disease course with evolution of symptoms. However, some authors have reported acute neurological deterioration in the setting of CM-I and acquired Chiari malformations. Although brainstem dysfunction has been documented in patients with CM-II and hydrocephalus or shunt malfunction, to the authors' knowledge only 1 report describing ventriculoperitoneal (VP) shunt malfunction causing neurological deterioration in a patient with CM-I exists. The authors report on their experience with the treatment of previously asymptomatic CM-I in 2 children who experienced quite different manifestations of acute neurological deterioration secondary to VP shunt malfunction. Presumably, VP shunt malfunction created a positive rostral pressure gradient across a stenotic foramen magnum, resulting in tetraparesis from foramen magnum syndrome in 1 patient and acute ataxia and cranial nerve deficits from syringobulbia in the other. Although urgent shunt revisions yielded partial recovery of neurological function in both patients, marked improvement occurred only after posterior fossa decompression.

  3. Placenta Percreta Invading Broad Ligament and Parametrium in a Woman with Two Previous Cesarean Sections: A Case Report

    Directory of Open Access Journals (Sweden)

    Mansoureh Vahdat

    2012-01-01

    Full Text Available Introduction. The incidence of placenta accreta has dramatically increased due to increasing caesarean section rate all over the world. Placenta percreta is the most severe form of placenta accretes. It frequently results in maternal morbidity and mortality mainly caused by massive obstetric hemorrhage or emergency hysterectomy. Percreta invading into the broad ligament has rarely been previously reported. Case presenting. We presented a case of placenta percreta invading left broad ligament and parametrium in a woman with two previous cesarean sections, which led to massive intraoperative hemorrhage during hysterectomy and transient ischemic encephalopathy. Conclusion. In cases of parametrial involvement, it would be more difficult to decide whether to remove placenta or leave it in site. In surgical removal neither local excision of placental bed and uterine repair nor traditional hysterectomy is adequate if parametrium invaded by placenta. We suggest delayed elective hysterectomy in such cases. So, pregnancy-induced pelvic congestion would be decreased, we can gather an expert team of gynecologists, urologists, and vascular surgeons, we could get plenty of blood products, and we may have the chance to administer methotrexate.

  4. [Double mutant alleles in the EXT1 gene not previously reported in a teenager with hereditary multiple exostoses].

    Science.gov (United States)

    Cammarata-Scalisi, Francisco; Cozar, Mónica; Grinberg, Daniel; Balcells, Susana; Asteggiano, Carla G; Martínez-Domenech, Gustavo; Bracho, Ana; Sánchez, Yanira; Stock, Frances; Delgado-Luengo, Wilmer; Zara-Chirinos, Carmen; Chacín, José Antonio

    2015-04-01

    Hereditary forms of multiple exostoses, now called EXT1/EXT2-CDG within Congenital Disorders of Glycosylation, are the most common benign bone tumors in humans and clinical description consists of the formation of several cartilage-capped bone tumors, usually benign and localized in the juxta-epiphyseal region of long bones, although wide body dissemination in severe cases is not uncommon. Onset of the disease is variable ranging from 2-3 years up to 13-15 years with an estimated incidence ranging from 1/18,000 to 1/50,000 cases in European countries. We present a double mutant alleles in the EXT1 gene not previously reported in a teenager and her family with hereditary multiple exostoses.

  5. Technical report of electronics shop characteristics of high speed electronics component, (1)

    International Nuclear Information System (INIS)

    Watanabe, Shin-ichi; Shiino, Kazuo.

    1975-01-01

    We must develop electronics circuits for high speed signals. The electronics components of the circuits make use of the special components. This report treats a pulse response of the electronics components (i.e. coaxial cable, connector, resistor, capacitor, diode, transistor) for high speed electronics. The results of this report was already applied constructions of high speed electronics circuits and experimental equipments of the High Energy Physics Division. (auth.)

  6. Electron interactions with nuclei: Progress report

    International Nuclear Information System (INIS)

    1988-08-01

    This paper contains information on the following topics: inclusive electron scattering; electroexcitation of Δ in nuclei; longitudinal and transverse response in the quasi-elastic region; electron scattering at MIT-Bates; detector development at LEGS; electron scattering at Saclay; intermediate energy nuclear interactions; research and development at CEBAF; and computing facilities

  7. Pushing the boundaries in liver graft utilisation in transplantation: Case report of a donor with previous bile duct injury repair.

    Science.gov (United States)

    Sultana, Asma; Powell, James J; Oniscu, Gabriel C

    2017-01-01

    Liver transplantation is a recognised treatment for extensive bile duct injuries with secondary biliary cirrhosis or recurring sepsis. However, there have been no reports of successful liver transplantation from a donor who sustained a previous bile duct injury. Here we discuss the case of a liver transplant from a 51-year-old brain dead donor who had suffered a Strasberg E1 bile duct injury and had undergone a Roux-en-Y hepaticojejunostomy 24 years prior to donation. The liver was successfully recovered and transplanted into a 56-year-old male recipient with end stage liver disease consequent to alpha 1 antitrypsin deficiency. The graft continues to function well 36 months post-transplant, with normal liver function tests and imaging revealing a patent hepaticojejunostomy. The potential associated vascular injuries should be identified during bench preparation whilst the management of biliary reconstruction at the time of transplant should follow the principles of biliary reconstruction in cases with biliary injuries, extending the hilar opening into the left duct. This case highlights the successful utilisation of a post bile duct injury repair liver, employing an experienced procurement team and careful bench assessment and reconstruction. Copyright © 2017. Published by Elsevier Ltd.

  8. Electron interactions with nuclei. Progress report

    International Nuclear Information System (INIS)

    1986-07-01

    Research includes work at SLAC, Bates, and Saclay research facilities. The high energy program at SLAC concerns inclusive electron scattering from nuclei, electroexcitation of the delta in nuclei, and the design of an electron detection system for the SLAC 1.6 GeV/c magnetic spectrometer. The high energy program at Bates includes quasielastic electron scattering from 1 H, 2 H, 3 He, and 4 He, and electron scattering from 3 H and 3 He. Nuclear structure studies are based on high resolution inelastic electron scattering and include electron scattering from 208 Pb and mercury isotopes, charge densities from low lying states in 86 Sr, and magnetization densities of 205 Tl and 207 Pb. (DWL) 72 refs., 29 figs., 1 tab

  9. External cephalic version among women with a previous cesarean delivery: report on 36 cases and review of the literature.

    Science.gov (United States)

    Abenhaim, Haim A; Varin, Jocelyne; Boucher, Marc

    2009-01-01

    Whether or not women with a previous cesarean section should be considered for an external cephalic version remains unclear. In our study, we sought to examine the relationship between a history of previous cesarean section and outcomes of external cephalic version for pregnancies at 36 completed weeks of gestation or more. Data on obstetrical history and on external cephalic version outcomes was obtained from the C.H.U. Sainte-Justine External Cephalic Version Database. Baseline clinical characteristics were compared among women with and without a history of previous cesarean section. We used logistic regression analysis to evaluate the effect of previous cesarean section on success of external cephalic version while adjusting for parity, maternal body mass index, gestational age, estimated fetal weight, and amniotic fluid index. Over a 15-year period, 1425 external cephalic versions were attempted of which 36 (2.5%) were performed on women with a previous cesarean section. Although women with a history of previous cesarean section were more likely to be older and para >2 (38.93% vs. 15.0%), there were no difference in gestational age, estimated fetal weight, and amniotic fluid index. Women with a prior cesarean section had a success rate similar to women without [50.0% vs. 51.6%, adjusted OR: 1.31 (0.48-3.59)]. Women with a previous cesarean section who undergo an external cephalic version have similar success rates than do women without. Concern about procedural success in women with a previous cesarean section is unwarranted and should not deter attempting an external cephalic version.

  10. Advanced Power Electronics and Electric Motors Annual Report -- 2013

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bennion, K. [National Renewable Energy Lab. (NREL), Golden, CO (United States); DeVoto, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Moreno, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rugh, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Waye, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-01-01

    This report describes the research into advanced liquid cooling, integrated power module cooling, high temperature air cooled power electronics, two-phase cooling for power electronics, and electric motor thermal management by NREL's Power Electronics group in FY13.

  11. JTEC Panel report on electronic manufacturing and packaging in Japan

    Science.gov (United States)

    Kelly, Michael J.; Boulton, William R. (Editor); Kukowski, John; Meieran, Gene; Pecht, Michael; Peeples, John; Tummala, Rao; Dehaemer, Michael J.; Holdridge, Geoff (Editor); Gamota, George

    1995-01-01

    This report summarizes the status of electronic manufacturing and packaging technology in Japan in comparison to that in the United States, and its impact on competition in electronic manufacturing in general. In addition to electronic manufacturing technologies, the report covers technology and manufacturing infrastructure, electronics manufacturing and assembly, quality assurance and reliability in the Japanese electronics industry, and successful product realization strategies. The panel found that Japan leads the United States in almost every electronics packaging technology. Japan clearly has achieved a strategic advantage in electronics production and process technologies. Panel members believe that Japanese competitors could be leading U.S. firms by as much as a decade in some electronics process technologies.

  12. Accurate assessment of adherence: self-report and clinician report vs electronic monitoring of nebulizers.

    Science.gov (United States)

    Daniels, Tracey; Goodacre, Lynne; Sutton, Chris; Pollard, Kim; Conway, Steven; Peckham, Daniel

    2011-08-01

    People with cystic fibrosis have a high treatment burden. While uncertainty remains about individual patient level of adherence to medication, treatment regimens are difficult to tailor, and interventions are difficult to evaluate. Self- and clinician-reported measures are routinely used despite criticism that they overestimate adherence. This study assessed agreement between rates of adherence to prescribed nebulizer treatments when measured by self-report, clinician report, and electronic monitoring suitable for long-term use. Seventy-eight adults with cystic fibrosis were questioned about their adherence to prescribed nebulizer treatments over the previous 3 months. Self-report was compared with clinician report and stored adherence data downloaded from the I-Neb nebulizer system. Adherence measures were expressed as a percentage of the prescribed regimen, bias was estimated by the paired difference in mean (95% CI) patient and clinician reported and actual adherence. Agreement between adherence measures was calculated using intraclass correlation coefficients (95% CI), and disagreements for individuals were displayed using Bland-Altman plots. Patient-identified prescriptions matched the medical record prescription. Median self-reported adherence was 80% (interquartile range, 60%-95%), whereas median adherence measured by nebulizer download was 36% (interquartile range, 5%-84.5%). Nine participants overmedicated and underreported adherence. Median clinician report ranged from 50% to 60%, depending on profession. Extensive discrepancies between self-report and clinician report compared with nebulizer download were identified for individuals. Self- and clinician-reporting of adherence does not provide accurate measurement of adherence when compared with electronic monitoring. Using inaccurate measures has implications for treatment burden, clinician prescribing practices, cost, and accuracy of trial data.

  13. Implementation of an electronic medical record system in previously computer-naïve primary care centres: a pilot study from Cyprus.

    Science.gov (United States)

    Samoutis, George; Soteriades, Elpidoforos S; Kounalakis, Dimitris K; Zachariadou, Theodora; Philalithis, Anastasios; Lionis, Christos

    2007-01-01

    The computer-based electronic medical record (EMR) is an essential new technology in health care, contributing to high-quality patient care and efficient patient management. The majority of southern European countries, however, have not yet implemented universal EMR systems and many efforts are still ongoing. We describe the development of an EMR system and its pilot implementation and evaluation in two previously computer-naïve public primary care centres in Cyprus. One urban and one rural primary care centre along with their personnel (physicians and nurses) were selected to participate. Both qualitative and quantitative evaluation tools were used during the implementation phase. Qualitative data analysis was based on the framework approach, whereas quantitative assessment was based on a nine-item questionnaire and EMR usage parameters. Two public primary care centres participated, and a total often health professionals served as EMR system evaluators. Physicians and nurses rated EMR relatively highly, while patients were the most enthusiastic supporters for the new information system. Major implementation impediments were the physicians' perceptions that EMR usage negatively affected their workflow, physicians' legal concerns, lack of incentives, system breakdowns, software design problems, transition difficulties and lack of familiarity with electronic equipment. The importance of combining qualitative and quantitative evaluation tools is highlighted. More efforts are needed for the universal adoption and routine use of EMR in the primary care system of Cyprus as several barriers to adoption exist; however, none is insurmountable. Computerised systems could improve efficiency and quality of care in Cyprus, benefiting the entire population.

  14. The Natural History of Juvenile or Subacute GM2 Gangliosidosis: 21 New Cases and Literature Review of 134 Previously Reported

    Science.gov (United States)

    Maegawa, Gustavo H. B.; Stockley, Tracy; Tropak, Michael; Banwell, Brenda; Blaser, Susan; Kok, Fernando; Giugliani, Roberto; Mahuran, Don; Clarke, Joe T. R.

    2010-01-01

    OBJECTIVE Juvenile GM2 gangliosidosis is a group of inherited neurodegenerative diseases caused by deficiency of lysosomal β-hexosaminidase resulting in GM2 ganglioside accumulation in brain. The purpose of this study was to delineate the natural history of the condition and identify genotype-phenotype correlations that might be helpful in predicting the course of the disease in individual patients. METHODS A cohort of 21 patients with juvenile GM2 gangliosidosis, 15 with the Tay-Sachs variant and 6 with the Sandhoff variant, was studied prospectively in 2 centers. Our experience was compared with previously published reports on 134 patients. Information about clinical features, β-hexosaminidase enzyme activity, and mutation analysis was collected. RESULTS In our cohort of patients, the mean (±SD) age of onset of symptoms was 5.3 ± 4.1 years, with a mean follow-up time of 8.4 years. The most common symptoms at onset were gait disturbances (66.7%), incoordination (52.4%), speech problems (28.6%), and developmental delay (28.6%). The age of onset of gait disturbances was 7.1 ± 5.6 years. The mean time for progression to becoming wheelchair-bound was 6.2 ± 5.5 years. The mean age of onset of speech problems was 7.0 ± 5.6 years, with a mean time of progression to anarthria of 5.6 ± 5.3 years. Muscle wasting (10.6 ± 7.4 years), proximal weakness (11.1 ± 7.7 years), and incontinence of sphincters (14.6 ± 9.7 years) appeared later in the course of the disease. Psychiatric disturbances and neuropathy were more prevalent in patients with the Sandhoff variant than in those with the Tay-Sachs variant. However, dysphagia, sphincter incontinence, and sleep problems occurred earlier in those with the Tay-Sachs variant. Cerebellar atrophy was the most common finding on brain MRI (52.9%). The median survival time among the studied and reviewed patients was 14.5 years. The genotype-phenotype correlation revealed that in patients with the Tay-Sachs variant, the presence

  15. Electron Donor Acceptor Interactions. Final Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Ana L. [Arizona State Univ., Tempe, AZ (United States)

    2002-08-16

    The Gordon Research Conference (GRC) on Electron Donor Acceptor Interactions was held at Salve Regina University, Newport, Rhode Island, 8/11-16/02. Emphasis was placed on current unpublished research and discussion of the future target areas in this field.

  16. Analysis of over 10,000 Cases finds no association between previously reported candidate polymorphisms and ovarian cancer outcome

    DEFF Research Database (Denmark)

    White, Kristin L; Vierkant, Robert A; Fogarty, Zachary C

    2013-01-01

    Ovarian cancer is a leading cause of cancer-related death among women. In an effort to understand contributors to disease outcome, we evaluated single-nucleotide polymorphisms (SNP) previously associated with ovarian cancer recurrence or survival, specifically in angiogenesis, inflammation, mitosis...

  17. Electron interactions with nuclei: Progress report

    International Nuclear Information System (INIS)

    McCarthy, J.S.

    1987-08-01

    High energy is being conducted at the Stanford Linear Accelerator Center. This includes inclusive electron scattering, electroexcitation of the delta in nuclei, longitudinal and transverse response in the quasi-elastic region, the q 2 dependence of 4 He(e,e'p), deep inelastic scattering from nuclei, transverse and longitudinal response in the resonance region, nuclear physics at PEP and 1.6 GeV spectrometer properties. Additional high energy research on electron scattering on 3 H and 3 He and the nuclear structure of 205 Tl and 206 Pb are being conducted at MIT-Bates. Other activities are being carried out at Saclay and research and development for Monte Carlo studies of Hall A spectrometers for CEBAF is being conducted

  18. Towards Electronic Marketplaces: A Progress Report

    OpenAIRE

    Babin, Gilbert; Crainic, Teodor Gabriel; Gendreau, Michel; Keller, Rudolf K.; Kropf, Peter; Robert, Jacques

    2010-01-01

    Market design is becoming a very important research topic in the context of the electronic economy. Two factors explain this trend: (1) the creation of new markets to facilitate deregulation (telecommunication frequencies, electric power, etc.) and (2) the emergence of strategic analysis and of experimental economics. E-commerce tools will contribute to the emergence of more structured marketplaces. Private service providers will begin offering price-discovery and demand-and-supply equilibrat...

  19. Rib cage deformity during two-stage tissue expander breast reconstruction in patient with previous radiotherapy: a case report

    Directory of Open Access Journals (Sweden)

    Aleš Porčnik

    2016-02-01

    Full Text Available Patients undergoing two-stage breast reconstruction with tissue expander and a history of previous irradiation are predisposed to a various chest-wall deformations more than non-irradiated patients. If chest-wall depression with/without rib fracture is found intra-operatively, bigger implant should be used, with a subsequent radiologic evaluation. In the future, the development of a new, modified expander with a harder base could minimise such complications.

  20. A Case Report of Salmonella muenchen Enteritis Causing Rhabdomyolysis and Myocarditis in a Previously Healthy 26-Year-Old Man.

    Science.gov (United States)

    Chapple, Will; Martell, Jon; Wilson, Joy S; Matsuura, Don T

    2017-04-01

    This case report examines an unusual presentation of a non-typhoidal Salmonella serovar with limited prevalence in the literature. This is the first case report to associate specifically the Salmonella muenchen serovar with rhabdomyolysis and myocarditis. This case report reviews the diagnostic criteria for myocarditis and explores the diagnostic dilemma of troponin elevation in the setting of rhabdomyolysis. It demonstrates that Salmonella muenchen has the ability to present in a broad range of individuals with complications extending beyond classical gastrointestinal symptoms. This report also concludes that diagnosis of the many possible complications from non-typhoidal Salmonella infections can be difficult due to patient comorbidities, variability in the severity of the illnesses, laboratory test limitations, and imaging limitations. When a patient presents with elevated troponins in the setting of rhabdomyolysis a careful workup should be done to evaluate for ischemic causes, myocarditis, or false elevation secondary to rhabdomyolysis.

  1. Continuation of the summarizing interim report on previous results of the Gorleben site survey as of May 1983

    International Nuclear Information System (INIS)

    1990-04-01

    In addition to results from the 1983 interim report, this report contains, in order to supplement the surface explorations, seismic reflection measurements, hydrogeologic and seismologic investigations, sorption experiments, and studies of glacial development in the site region and of long-term safety of final waste repositories in salt domes. The site's high grade of suitability for becoming a final radioactive waste repository, the legal basis as well as quality assurance are evaluated. (orig.) [de

  2. 24 CFR 1710.558 - Previously accepted state filings-notice of revocation rights on property report cover page.

    Science.gov (United States)

    2010-04-01

    ... will give the purchaser written notification of purchaser's default or breach of contract and the... purchaser loses rights and interest in the lot because of the purchaser's default or breach of contract... Report prior to signing a contract or agreement, you may cancel your contract or agreement by giving...

  3. Leptotrichia endocarditis: report of two cases from the International Collaboration on Endocarditis (ICE) database and review of previous cases

    NARCIS (Netherlands)

    Caram, L. B.; Linefsky, J. P.; Read, K. M.; Murdoch, D. R.; Lalani, T.; Woods, C. W.; Reller, L. B.; Kanj, S. S.; Premru, M. M.; Ryan, S.; Al-Hegelan, M.; Donnio, P. Y.; Orezzi, C.; Paiva, M. G.; Tribouilloy, C.; Watkin, R.; Harris, O.; Eisen, D. P.; Corey, G. R.; Cabell, C. H.; Petti, C. A.; Gordon, David; Devi, Uma; Spelman, Denis; van der Meer, Jan T. M.; Kauffman, Carol; Bradley, Suzanne; Armstrong, William; Giannitsioti, Efthymia; Giamarellou, Helen; Lerakis, Stamatios; del Rio, Ana; Moreno, Asuncion; Mestres, Carlos A.; Paré, Carlos; de la Maria, Cristina Garcia; de Lazzario, Elisa; Marco, Francesc; Gatell, Jose M.; Miró, José M.; Almela, Manel; Azqueta, Manuel; Jiménez-Expósito, Maria Jesús; de Benito, Natividad; Perez, Noel; Almirante, Benito; Fernandez-Hidalgo, Nuria; de Vera, Pablo Rodriguez; Tornos, Pilar; Falcó, Vicente

    2008-01-01

    Leptotrichia species typically colonize the oral cavity and genitourinary tract. We report the first two cases of endocarditis secondary to L. goodfellowii sp. nov. Both cases were identified using 16S rRNA gene sequencing. Review of the English literature revealed only two other cases of

  4. Central posterior capsule pigmentation in a patient with pigment dispersion and previous ocular trauma: a case report.

    Science.gov (United States)

    Al-Mezaine, Hani S

    2010-01-01

    We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg's spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger's from the posterior chamber.

  5. Central posterior capsule pigmentation in a patient with pigment dispersion and previous ocular trauma: A case report

    Directory of Open Access Journals (Sweden)

    Al-Mezaine Hani

    2010-01-01

    Full Text Available We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg′s spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger′s from the posterior chamber.

  6. Columbus electronic freight management evaluation final report : June 2008.

    Science.gov (United States)

    2008-06-01

    This document provides the independent evaluation of the USDOT-sponsored Columbus Electronic Freight Management (CEFM) Operational Test, which occurred from late May 2007 until December 2007. The Evaluation report includes descriptions of the CEFM sy...

  7. Accomplishments Report for the National Strategy for Electronics Stewardship

    Science.gov (United States)

    This page holds the NSES report, which charts the progress and accomplishments of the NSES in addressing sustainable management of electronics and highlights the benefits of continued leadership from the federal government.

  8. Neutrino-electron scattering. Progress report

    International Nuclear Information System (INIS)

    White, D.H.

    1982-01-01

    We present here a progress report on an experiment to measure the cross section for nu/sub μ/e scattering at the Brookhaven AGS. A wide band focussing horn is used with a neutrino beam energy centered at 1.5 GeV. We have in hand measurements with nu/sub μ/ and anti nu/sub μ/ beams but we present preliminary data on the nu/sub μ/ beam running only. We also measure the reactions: nu/sub μ/ + n → μ - + p and nu/sub e/ + n → e - + p which will be used in normalization and in background estimation

  9. VISA Final Report: Fully Integrated Power Electronic Systems in Automotive Electronics

    NARCIS (Netherlands)

    Waffenschmidt, E.

    2011-01-01

    This report summarizes the activities related to the public funded project “Vollintegrierte leistungselektronische Systeme in der Automobilelektronik – VISA” (Fully Integrated Power Electronic Systems in Automotive Electronics). Aim of the project is to investigate the integration of components into

  10. 77 FR 13061 - Electronic Reporting of Toxics Release Inventory Data

    Science.gov (United States)

    2012-03-05

    ...--Reporting Year SIC--Standard Industrial Code TRI--Toxics Release Inventory TRI-ME--TRI-Made Easy Desktop... EPA to ``publish a uniform toxic chemical release form for facilities covered'' by the TRI Program. 42... practicable. Similarly, EPA's Cross-Media Electronic Reporting Regulation (CROMERR) (40 CFR Part 3), published...

  11. Unexpected finding of T-cell lymphoma in a previously healthy 16-year-old patient after a thorax trauma: a case report

    DEFF Research Database (Denmark)

    Bach Okholm-Hansen, Anna; Brorson, Stig

    2014-01-01

    INTRODUCTION: We describe the clinical course and emphasize the difficulties in diagnosing T-cell lymphoblastic lymphoma. The differential diagnostic difficulties have previously been described in regard to pneumonia, but to the best of the authors' knowledge this is the first case report to desc...... relevant to pediatricians, surgeons, anesthesiologists, and general practitioners....

  12. Biennial report [for] 1978 and 1979, Electronics Division

    International Nuclear Information System (INIS)

    1980-01-01

    The activities of the Electronics Division of the Bhabha Atomic Research Centre, Bombay, during the calendar years 1978-1979 are reported. The Division designed and fabricated electronic equipment and instruments for use in the fields of nuclear science, nuclear reactors, microcomputer hardware and software, health and safety, medicine, chemical analysis and industry. Many of these are described in brief mentioning their special features and in many cases block diagrams are given. (M.G.B.)

  13. Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P; Flom, Z; Heinselman, K; Nguyen, T; Tung, S; Haskell, R; Reed, B W; LaGrange, T

    2011-08-04

    The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

  14. Electronic case report forms and electronic data capture within clinical trials and pharmacoepidemiology.

    Science.gov (United States)

    Rorie, David A; Flynn, Robert W V; Grieve, Kerr; Doney, Alexander; Mackenzie, Isla; MacDonald, Thomas M; Rogers, Amy

    2017-09-01

    Researchers in clinical and pharmacoepidemiology fields have adopted information technology (IT) and electronic data capture, but these remain underused despite the benefits. This review discusses electronic case report forms and electronic data capture, specifically within pharmacoepidemiology and clinical research. The review used PubMed and the Institute of Electrical and Electronic Engineers library. Search terms used were agreed by the authors and documented. PubMed is medical and health based, whereas Institute of Electrical and Electronic Engineers is technology based. The review focuses on electronic case report forms and electronic data capture, but briefly considers other relevant topics; consent, ethics and security. There were 1126 papers found using the search terms. Manual filtering and reviewing of abstracts further condensed this number to 136 relevant manuscripts. The papers were further categorized: 17 contained study data; 40 observational data; 27 anecdotal data; 47 covering methodology or design of systems; one case study; one literature review; two feasibility studies; and one cost analysis. Electronic case report forms, electronic data capture and IT in general are viewed with enthusiasm and are seen as a cost-effective means of improving research efficiency, educating participants and improving trial recruitment, provided concerns about how data will be protected from misuse can be addressed. Clear operational guidelines and best practises are key for healthcare providers, and researchers adopting IT, and further work is needed on improving integration of new technologies with current systems. A robust method of evaluation for technical innovation is required. © 2017 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  15. Ballistic trauma from an exploding electronic cigarette: Case report

    Directory of Open Access Journals (Sweden)

    Christopher Ban, DMD

    2017-09-01

    Full Text Available Electronic cigarettes (e-cigarettes first became available in the United States in 2007, and since that time, the number of e-cigarette users in the US has grown to over 2.5 million. During the period from 2010–2013 alone, the percentage of Americans who reported that they had ever used electronic cigarettes more than doubled from 3.3% to 8.5%. This number will continue to grow, as the use of electronic cigarettes as an alternative to smoking and in smoking cessation is being explored by the public and medical professionals alike. This article presents a case report involving a patient who was injured when the electronic cigarette he was smoking exploded in his face, causing a ballistic injury to his maxilla, as well as a series of other associated injuries. There have been several recent reports in the literature of exploding electronic cigarettes. This article presents a case of avulsive injury due to ballistic trauma with associated impaction of the vaporizing device.

  16. Status report on the relativistic electron beam technology

    International Nuclear Information System (INIS)

    Iyyengar, S.K.; Ron, P.H.; Rohatgi, V.K.

    1974-01-01

    The status of technology of the pulsed relativistic electron beam (REB) has been examined and summarised in this report. With the present technology the beam generator can be used either as a source of intense electron burst or to produce bursts of positive ions x and γ-rays, and neutrons by suitable secondary reactions. A large number of applications have been identified where this technology can play an important role. Typical applications of the technology include : (a) generation and heating of fusion plasma (b) development of high power laser and (c) sterilisation and radiation sources. The present day cost of radiation produced by REB is competitive with the cost of radiation produced from Co 60 source. At the same time there are indications that the cost of radiation from REB source can be significantly reduced with advanced technology. The type of equipment developed by various laboratories to study realitivistic electron beams is also included in this report. (author)

  17. Electron-beam-fusion progress report, January--June 1976

    International Nuclear Information System (INIS)

    1976-10-01

    Research progress is reported for the following areas: (1) Proto I, (2) Proto II, (3) EBFA, (4) power flow, (5) contract progress reports, (6) progress in the Sandia program, (7) repetitively operated pulse generator development, (8) electron beam power from inductive storage, (9) fusion target design, (10) beam physics research, (11) power flow, (12) heavy ion fusion, (13) particle beam source development, (14) beam target interaction and target response studies, (15) diagnostic development, and (16) hybrid systems

  18. Electronic error-reporting systems: a case study into the impact on nurse reporting of medical errors.

    Science.gov (United States)

    Lederman, Reeva; Dreyfus, Suelette; Matchan, Jessica; Knott, Jonathan C; Milton, Simon K

    2013-01-01

    Underreporting of errors in hospitals persists despite the claims of technology companies that electronic systems will facilitate reporting. This study builds on previous analyses to examine error reporting by nurses in hospitals using electronic media. This research asks whether the electronic media creates additional barriers to error reporting, and, if so, what practical steps can all hospitals take to reduce these barriers. This is a mixed-method case study nurses' use of an error reporting system, RiskMan, in two hospitals. The case study involved one large private hospital and one large public hospital in Victoria, Australia, both of which use the RiskMan medical error reporting system. Information technology-based error reporting systems have unique access problems and time demands and can encourage nurses to develop alternative reporting mechanisms. This research focuses on nurses and raises important findings for hospitals using such systems or considering installation. This article suggests organizational and technical responses that could reduce some of the identified barriers. Crown Copyright © 2013. Published by Mosby, Inc. All rights reserved.

  19. Review of safety reports involving electronic flight bags

    Science.gov (United States)

    2009-04-27

    Electronic Flight Bags (EFBs) are a relatively new device used by pilots. Even so, 37 safety-related events involving EFBs were identified from the public online Aviation Safety Reporting System (ASRS) database as of June 2008. In addition, two accid...

  20. Electronics Engineering Department Thrust Area report FY'84

    International Nuclear Information System (INIS)

    Minichino, C.; Phelps, P.L.

    1984-01-01

    This report describes the work of the Electronics Engineering Department Thrust Areas for FY'84: diagnostics and microelectronic engineering; signal and control engineering; microwave and pulsed power engineering; computer-aided engineering; engineering modeling and simulation; and systems engineering. For each Thrust Area, an overview and a description of the goals and achievements of each project is provided

  1. NREL Scientists Report First Solar Cell Producing More Electrons In

    Science.gov (United States)

    measured in operating quantum dot solar cells at low light intensity; these cells showed significant power Photocurrent Than Solar Photons Entering Cell | News | NREL NREL Scientists Report First Solar Cell Producing More Electrons In Photocurrent Than Solar Photons Entering Cell News Release: NREL

  2. Electronic clinical safety reporting system: a benefits evaluation.

    Science.gov (United States)

    Elliott, Pamela; Martin, Desmond; Neville, Doreen

    2014-06-11

    Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use

  3. Bibliography of low energy electron and photon cross section data. Report for Jan 1975-Dec 1977

    International Nuclear Information System (INIS)

    Gallagher, J.W.; Rumble, J.R. Jr; Beaty, E.C.

    1979-06-01

    A bibliography of original reports of measurements or calculations of electron, positron, and photon cross sections for atoms, small molecules, and their ions is presented. A detailed index to the bibliography facilitates retrieval of cross section data for specific processes and associated atomic or molecular species. A comprehensive author index is included. The bibliography covers the calendar years 1975-1977. This work supplements a previous bibliography which covered the literature through 1974

  4. Laser-Electron-Gamma-Source. Progress report, July 1986

    International Nuclear Information System (INIS)

    Dowell, D.H.; Fineman, B.; Giordano, G.; Kistner, OC.; Matone, G.; Sandorfi, A.M.; Schaerf, C.; Thorn, C.E.; Ziegler, W.

    1986-07-01

    When completed, the Laser Electron Gamma Source (LEGS) is expected to provide intense beams of monochromatic and polarized (circular or linear) gamma rays with energies up to 500 MeV. The gamma-ray beams will be produced by Compton backscattering uv laser light from the electrons circulating in a storage ring. Progress with installation of the facility is described, particularly the Ar-ion laser and tagging spectrometer. Tests of the tagging spectrometer coponents is reported, and a second laser is described for higher energy operation. Estimates are given of expected beam parameters. Experimental equipment for the planned research projects to be carried out at the LEGS facility is discussed

  5. Electronic brachytherapy management of atypical fibroxanthoma: report of 8 lesions

    Directory of Open Access Journals (Sweden)

    Stephen Doggett

    2017-01-01

    Full Text Available Purpose : To evaluate the suitability of treating atypical fibroxanthoma (AFX, an uncommon skin malignancy, with electronic brachytherapy. Material and methods : From Feb 2013 to Sep 2014, we were referred a total of 8 cases of AFX in 7 patients, all involving the scalp. All of them were treated with electronic brachytherapy 50 Kev radiations (Xoft Axxent®, Fremont, California. All lesions received 40 Gy in two fractions per week with 5mm margins. Results : At a median follow-up of 23.7 months, the local recurrence rate is 12.5%. The single lesion that failed was not debulked surgically prior to electronic brachytherapy. Conclusions : To our knowledge, this is the first report in the literature on the use of radiation therapy as curative primary treatment for AFX. No contraindication to the use of radiations is found in the literature, with surgery being the sole treatment for AFX noted. Our recurrence rate is 0% for debulked lesions. Risk of recurrence is mitigated with surgical debulking prior to brachytherapy. Electronic brachytherapy appears to be a safe and effective treatment for debulked AFX. Multiple excisions, skin grafting, and wound care can be avoided in elderly patients by the use of electronic brachytherapy.

  6. [Metatropic dysplasia in a girl with c.1811_1812delinsAT mutation in exon 11 of the TRPV4 gene not previously reported].

    Science.gov (United States)

    Cammarata-Scalisi, Francisco; Matysiak-Scholze, Uta; Heinze, Jessica; Barrera, Albaro; Lacruz-Rengel, María Angelina; Bracho, Ana; Guerrero, Yudith

    2015-01-01

    Metatropic dysplasia is a skeletal disorder with clinical heterogeneity, characterized by craniofacial dysmorphy including frontal bossing and midface hypoplasia, short trunk,progressive kyphoscoliosis and shortened limbs. The TRPV4 gene is located on 12q24.11, coding a cation channel with nonselective permeability to calcium; it is expressed and involved in many physiological processes through responses to different stimuli. Over 50 mutations in TRPV4 have been described. We present a seven months old girl with heterozygous mutation c.1811_1812delinsAT; p.I604N in intron 11 not previously reported in the TRPV4 gene and with clinical findings compatible with metatropic dysplasia.

  7. NASAwide electronic publishing system: Prototype STI electronic document distribution, stage-4 evaluation report

    Science.gov (United States)

    Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy

    1996-01-01

    This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual frame work, functional description, and technical report server of the STI Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware, and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices, which arc contained in Part 2 of this document, consist of (1) STI EDD Project Plan, (2) Team members, (3) Phasing Schedules, (4) Accessing On-line Reports, and (5) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desktop publishing systems, and technical report servers to be able to provide to NASA's engineers, researchers, scientists, and external users the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.

  8. New Record of Sillago sinica (Pisces: Sillaginidae in Korean Waters, and Re-identification of Sillago parvisquamis Previously Reported from Korea as S. sinica

    Directory of Open Access Journals (Sweden)

    Seung Eun Bae

    2013-10-01

    Full Text Available A single specimen of the genus Sillago, collected from Gwangyang, Korea, in May 2009, is characterized by XI first dorsal fin spines, 3 or 4 rows of melanophore pattern along the second dorsal fin membrane, and a darkish posterior margin of the caudal fin. Our specimen was identified as Sillago sinica reported as a new species; this identification is confirmed by mitochondrial DNA cytochrome oxidase subunit I sequences, which show that our specimen corresponds to S. sinica (d=0.000 and differs from the congeneric species Sillago parvisquamis (d=0.170. Comparisons of Korean specimens previously reported as S. parvisquamis with specimens of S. sinica show that the S. parvisquamis specimens are actually S. sinica. We propose the new Korean name “buk-bang-jeom-bo-ri-myeol” for S. sinica.

  9. Patient Compliance With Electronic Patient Reported Outcomes Following Shoulder Arthroscopy.

    Science.gov (United States)

    Makhni, Eric C; Higgins, John D; Hamamoto, Jason T; Cole, Brian J; Romeo, Anthony A; Verma, Nikhil N

    2017-11-01

    To determine the patient compliance in completing electronically administered patient-reported outcome (PRO) scores following shoulder arthroscopy, and to determine if dedicated research assistants improve patient compliance. Patients undergoing arthroscopic shoulder surgery from January 1, 2014, to December 31, 2014, were prospectively enrolled into an electronic data collection system with retrospective review of compliance data. A total of 143 patients were included in this study; 406 patients were excluded (for any or all of the following reasons, such as incomplete follow-up, inaccessibility to the order sets, and inability to complete the order sets). All patients were assigned an order set of PROs through an electronic reporting system, with order sets to be completed prior to surgery, as well as 6 and 12 months postoperatively. Compliance rates of form completion were documented. Patients who underwent arthroscopic anterior and/or posterior stabilization were excluded. The average age of the patients was 53.1 years, ranging from 20 to 83. Compliance of form completion was highest preoperatively (76%), and then dropped subsequently at 6 months postoperatively (57%) and 12 months postoperatively (45%). Use of research assistants improved compliance by approximately 20% at each time point. No differences were found according to patient gender and age group. Of those completing forms, a majority completed forms at home or elsewhere prior to returning to the office for the clinic visit. Electronic administration of PRO may decrease the amount of time required in the office setting for PRO completion by patients. This may be mutually beneficial to providers and patients. It is unclear if an electronic system improves patient compliance in voluntary completion PRO. Compliance rates at final follow-up remain a concern if data are to be used for establishing quality or outcome metrics. Level IV, case series. Copyright © 2017 Arthroscopy Association of North

  10. Prospective evaluation of patient-reported quality-of-life outcomes following SBRT ± cetuximab for locally-recurrent, previously-irradiated head and neck cancer

    International Nuclear Information System (INIS)

    Vargo, John A.; Heron, Dwight E.; Ferris, Robert L.; Rwigema, Jean-Claude M.; Wegner, Rodney E.; Kalash, Ronny; Ohr, James; Kubicek, Greg J.; Burton, Steven

    2012-01-01

    Purpose: Stereotactic body radiotherapy (SBRT) has emerged as a promising salvage strategy for unresectable, previously-irradiated recurrent squamous cell carcinomas of the head and neck (rSCCHN). Here-in, we report the first prospective evaluation of patient-reported quality-of-life (PR-QoL) following re-irradiation with SBRT ± cetuximab for rSCCHN. Materials and methods: From November 2004 to May 2011, 150 patients with unresectable, rSCCHN in a previously-irradiated field receiving >40 Gy were treated with SBRT to 40–50 Gy in 5 fractions ± concurrent cetuximab. PR-QoL was prospectively acquired using University of Washington Quality-of-Life Revised (UW-QoL-R). Results: Overall PR-QoL, health-related PR-QoL, and select domains commonly affected by re-irradiation progressively increase following an initial 1-month decline with statistically significant improvements noted in swallowing (p = 0.025), speech (p = 0.017), saliva (p = 0.041), activity (p = 0.032) and recreation (p = 0.039). Conclusions: Especially for patients surviving >1-year, improved tumor control associated with SBRT re-irradiation may ameliorate decreased PR-QoL resulting from rSCCHN. These improvements in PR-QoL transcend all measured domains in a validated PR-QoL assessment tool independent of age, use of cetuximab, tumor volume, and interval since prior irradiation.

  11. Prospective monitoring and self-report of previous falls among older women at high risk of falls and fractures: a study of comparison and agreement.

    Science.gov (United States)

    Garcia, Patrícia A; Dias, João M D; Silva, Silvia L A; Dias, Rosângela C

    2015-01-01

    The identification of the occurrence of falls is an important step for screening and for rehabilitation processes for the elderly. The methods of monitoring these events are susceptible to recording biases, and the choice of the most accurate method remains challenging. (i) To investigate the agreement between retrospective self-reporting and prospective monitoring of methods of recording falls, and (ii) to compare the retrospective self-reporting of falls and the prospective monitoring of falls and recurrent falls over a 12-month period among older women at high risk of falls and fractures. A total of 118 community-dwelling older women with low bone density were recruited. The incidence of falls was monitored prospectively in 116 older women (2 losses) via monthly phone calls over the course of a year. At the end of this monitoring period, the older women were asked about their recall of falls in the same 12-month period. The agreement between the two methods was analyzed, and the sensitivity and specificity of self-reported previous falls in relation to the prospective monitoring were calculated. There was moderate agreement between the prospective monitoring and the retrospective self-reporting of falls in classifying fallers (Kappa = 0.595) and recurrent fallers (Kappa = 0.589). The limits of agreement were 0.35 ± 1.66 falls. The self-reporting of prior falls had a 67.2% sensitivity and a 94.2% specificity in classifying fallers among older women and a 50% sensitivity and a 98.9% specificity in classifying recurrent fallers. Self-reporting of falls over a 12-month period underestimated 32.8% of falls and 50% of recurrent falls. The findings recommend caution if one is considering replacing monthly monitoring with annual retrospective questioning.

  12. GeV C.W. electron microtron design report

    International Nuclear Information System (INIS)

    1982-05-01

    Rising interest in the nuclear physics community in a GeV C.W. electron accelerator reflects the growing importance of high-resolution short-range nuclear physics to future advances in the field. In this report major current problems are reviewed and the details of prospective measurements which could be made with a GeV C.W. electron facility are discussed, together with their impact on an understanding of nuclear forces and the structure of nuclear matter. The microtron accelerator has been chosen as the technology to generate the electron beams required for the research discussed because of the advantages of superior beam quality, low capital and operating cost and capability of furnishing beams of several energies and intensities simultaneously. A complete technical description of the conceptual design for a 2 GeV double-sided C.W. electron microtron is presented. The accelerator can furnish three beams with independently controlled energy and intensity. The maximum current per beam is 100 μamps. Although the precise objective for maximum beam energy is still a subject of debate, the design developed in this study provides the base technology for microtron accelerators at higher energies (2 to 6 GeV) using multi-sided geometries

  13. GeV C. W. electron microtron design report

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    Rising interest in the nuclear physics community in a GeV C.W. electron accelerator reflects the growing importance of high-resolution short-range nuclear physics to future advances in the field. In this report major current problems are reviewed and the details of prospective measurements which could be made with a GeV C.W. electron facility are discussed, together with their impact on an understanding of nuclear forces and the structure of nuclear matter. The microtron accelerator has been chosen as the technology to generate the electron beams required for the research discussed because of the advantages of superior beam quality, low capital and operating cost and capability of furnishing beams of several energies and intensities simultaneously. A complete technical description of the conceptual design for a 2 GeV double-sided C.W. electron microtron is presented. The accelerator can furnish three beams with independently controlled energy and intensity. The maximum current per beam is 100 ..mu..amps. Although the precise objective for maximum beam energy is still a subject of debate, the design developed in this study provides the base technology for microtron accelerators at higher energies (2 to 6 GeV) using multi-sided geometries.

  14. Hepatocellular Carcinoma Metastasis to the Orbit in a Coinfected HIV+ HBV+ Patient Previously Treated with Orthotopic Liver Transplantation: A Case Report

    Directory of Open Access Journals (Sweden)

    S. Guerriero

    2011-01-01

    Full Text Available Hepatocellular carcinoma rarely metastasizes to the orbit. We report a 45-year-old male, HBV+, HIV+, with a past history of a liver transplant for ELSD (end-stage liver disease with hepatocellular carcinoma and recurrent HCC, who presented with proptosis and diplopia of the left eye. CT scans of the head revealed a large, irregular mass in the left orbit causing superior and lateral destruction of the orbital bone. Biopsy specimens of the orbital tumor showed features of metastatic foci of hepatocellular carcinoma. Only 16 other cases of HCC metastasis to the orbit have been described in literature, and this is the first case in a previously transplanted HIV+, HBV+ patient.

  15. 76 FR 59542 - Mandatory Reporting of Greenhouse Gases: Changes to Provisions for Electronics Manufacturing To...

    Science.gov (United States)

    2011-09-27

    ... Mandatory Reporting of Greenhouse Gases: Changes to Provisions for Electronics Manufacturing To Provide... regulation to amend the calculation and monitoring provisions in the Electronics Manufacturing portion of the... Electronics Manufacturing 334111 Microcomputer manufacturing facilities. 334413 Semiconductor, photovoltaic...

  16. 76 FR 36472 - Mandatory Reporting of Greenhouse Gases; Changes to Provisions for Electronics Manufacturing...

    Science.gov (United States)

    2011-06-22

    ... Mandatory Reporting of Greenhouse Gases; Changes to Provisions for Electronics Manufacturing (Subpart I) To... proposing changes to the calculation and monitoring provisions in the Electronics Manufacturing portion... Category Examples of affected Category NAICS facilities Electronics Manufacturing......... 334111...

  17. Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency: A Concise Follow-up, at a Minimum of 10 Years, of Previous Reports.

    Science.gov (United States)

    Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G; Clark, Rachel E; Frankle, Mark A

    2017-11-15

    We previously evaluated 94 patients (96 shoulders) who underwent reverse shoulder arthroplasty using a central compressive screw with 5.0-mm peripheral locking screws for baseplate fixation and a center of rotation lateral to the glenoid as treatment for end-stage rotator cuff deficiency. The purpose of this study was to report updated results at a minimum follow-up of 10 years. Forty patients (42 shoulders) were available for clinical follow-up. In the patients available for study, implant survivorship, with the end point being revision for any reason, was 90.7%. Since our 5-year report, 2 patients underwent revision surgery; 1 patient sustained a periprosthetic fracture 7 years postoperatively and 1 patient had a dislocation because of chronic shoulder instability at 8 years postoperatively. At a minimum follow-up of 10 years, the patients continued to maintain their improved outcome scores and range of motion, which were comparable with earlier follow-up evaluations. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  18. Effect of electronic report writing on the quality of nursing report recording

    Science.gov (United States)

    Heidarizadeh, Khadijeh; Rassouli, Maryam; Manoochehri, Houman; Tafreshi, Mansoureh Zagheri; Ghorbanpour, Reza Kashef

    2017-01-01

    Background and Aim Recording performed nursery actions is one of the main chores of nurses. The findings have shown that recorded reports are not qualitatively valid. Since electronic reports can be regarded as a base to write reports, this study aims at determining the effect of utilizing electronic nursing reports on the quality of the records. Methods This quasi-experimental study was conducted with the aim of applying an electronic system of nursing recording in the heart department of Shahid Rahimi Medical Center, Lorestan University of Medical Science. The samples were nursing reports on the hospitalized patients in the heart department, the basis of complete enumeration (census) during the fall of 2014. The subjects were sixteen employed nurses. To do the study, the software of nursing records was set based on the Clinical Care Classification system (CCC). The research’s tool was the checklist of the Standards of Nursing Documentation. Results The findings indicated that before and after the intervention, the amount of reports’ adaption with the written standards, respectively, was (21.8%) and (71.3%), and the most complete recording was medicine status (58%) and (100%). The worst complete recording before the intervention, acute changes was (99.1%) and nursing processes was (78%) and after, the medicine status, intake and output status and patient’s education (100%); while the nursing report structure was regarded in all cases (100%). The results showed that there is a significant difference in the quality of reporting before and after using CCC (pnurses are reminded to record the necessary parts and from the other point, the system does not allow the user to shut it down unless the necessary parameters are recorded. For this reason, the quality of recorded reports with electronic reporting improves. PMID:29238481

  19. Water-clear cell adenoma of the parathyroid. A case report with immunohistochemistry and electron microscopy.

    Science.gov (United States)

    Grenko, R T; Anderson, K M; Kauffman, G; Abt, A B

    1995-11-01

    We report a water-clear cell adenoma of the parathyroid gland, a lesion which to our knowledge has not been described previously. Like its rare but well-described hyperplastic counterpart, water-clear cell hyperplasia, this adenoma is composed of cells with abundant foamy-to-granular cytoplasm and mild nuclear pleomorphism. The cells form glandular structures and cell nests separated by fine fibrovascular septae. The tumor cells stain positively with anti-parathyroid hormone and show characteristic glassy and flocculate material by electron microscopy. Unlike water-clear cell hyperplasia, water-clear cell adenoma is a solitary lesion that compresses the residual nonneoplastic parathyroid gland.

  20. Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report

    International Nuclear Information System (INIS)

    Nation, J.A.

    1992-01-01

    This report describes work carried out on DOE contract number DE-AC02-80ER10569 during the period December 15, 1979 to May 31, 1992. The original purpose of this research was to investigate the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three major objectives: development of a suitable ion injector, growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components into a suitable proof-of-principle demonstration of the wave accelerator. Work focused on the first two of these objectives. Control of the space charge waves' phase velocity was not obtained to the degree required for a working accelerator, so the project was duly terminated in favor of a program which focused on generating ultra high power microwave signals suitable for use in the next linear collider. Work done to develop suitable efficient, inexpensive, phase-stable microwave sources, with peak powers of up to 1 GW in the X band in pulses shorter than 1 ns, is described. Included are lists of the journal and conference papers resulting from this work, as well as a list of graduate students who completed their Ph.D. studies on the projects described in this report

  1. Case report of right hamate hook fracture in a patient with previous fracture history of left hamate hook: is it hamate bipartite?

    Directory of Open Access Journals (Sweden)

    Norton Sandra

    2006-10-01

    Full Text Available Abstract Background Hamate hook fracture is a common fracture in golfers and others who play sports that involve rackets or sticks such as tennis or hockey. This patient had a previous hamate fracture in the opposing wrist along with potential features of hamate bipartite. Case presentation A 19 year old male presented with a complaint of right wrist pain on the ulnar side of the wrist with no apparent mechanism of injury. The pain came on gradually one week before being seen in the office and he reported no prior care for the complaint. His history includes traumatic left hamate hook fracture with surgical excision. Conclusion The patient was found to have marked tenderness over the hamate and with a prior fracture to the other wrist, computed tomography of the wrist was ordered revealing a fracture to the hamate hook in the right wrist. He was referred for surgical evaluation and the hook of the hamate was excised. Post-surgically, the patient was able to return to normal activity within eight weeks. This case is indicative of fracture rather than hamate bipartite. This fracture should be considered in a case of ulnar sided wrist pain where marked tenderness is noted over the hamate, especially after participation in club or racket sports.

  2. Characterization of Cladosporols from the Marine Algal-Derived Endophytic Fungus Cladosporium cladosporioides EN-399 and Configurational Revision of the Previously Reported Cladosporol Derivatives.

    Science.gov (United States)

    Li, Hong-Lei; Li, Xiao-Ming; Mándi, Attila; Antus, Sándor; Li, Xin; Zhang, Peng; Liu, Yang; Kurtán, Tibor; Wang, Bin-Gui

    2017-10-06

    Four new cladosporol derivatives, cladosporols F-I (1-4), the known cladosporol C (5), and its new epimer, cladosporol J (6), were isolated and identified from the marine algal-derived endophytic fungus Cladosporium cladosporioides EN-399. Their structures were determined by detailed interpretation of NMR and MS data, and the absolute configurations were established on the basis of TDDFT-ECD and OR calculations. The configurational assignment of cladosporols F (1) and G (2) showed that the previously reported absolute configuration of cladosporol A and all the related cladosporols need to be revised from (4'R) to (4'S). Compounds 1-6 showed antibacterial activity against Escherichia coli, Micrococcus luteus, and Vibrio harveyi with MIC values ranging from 4 to 128 μg/mL. Compound 3 showed significant cytotoxicity against A549, Huh7, and LM3 cell lines with IC 50 values of 5.0, 1.0, and 4.1 μM, respectively, and compound 5 showed activity against H446 cell line with IC 50 value of 4.0 μM.

  3. Overcoming barriers to implementing patient-reported outcomes in an electronic health record: a case report.

    Science.gov (United States)

    Harle, Christopher A; Listhaus, Alyson; Covarrubias, Constanza M; Schmidt, Siegfried Of; Mackey, Sean; Carek, Peter J; Fillingim, Roger B; Hurley, Robert W

    2016-01-01

    In this case report, the authors describe the implementation of a system for collecting patient-reported outcomes and integrating results in an electronic health record. The objective was to identify lessons learned in overcoming barriers to collecting and integrating patient-reported outcomes in an electronic health record. The authors analyzed qualitative data in 42 documents collected from system development meetings, written feedback from users, and clinical observations with practice staff, providers, and patients. Guided by the Unified Theory on the Adoption and Use of Information Technology, 5 emergent themes were identified. Two barriers emerged: (i) uncertain clinical benefit and (ii) time, work flow, and effort constraints. Three facilitators emerged: (iii) process automation, (iv) usable system interfaces, and (v) collecting patient-reported outcomes for the right patient at the right time. For electronic health record-integrated patient-reported outcomes to succeed as useful clinical tools, system designers must ensure the clinical relevance of the information being collected while minimizing provider, staff, and patient burden. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. PEDRO (Petroleum Electronic Data Reporting Option) user guide

    Energy Technology Data Exchange (ETDEWEB)

    1990-11-01

    PEDRO is an electronic data communications product that simplifies filing and transmission of petroleum survey data. Your burden is significantly reduced as PEDRO eliminates paperwork, provides immediate onsite correction of data errors, and reduces the need for followup calls and survey resubmission. PEDRO provides an online error-checking process that highlights discrepancies. This permits you to enter and check data before transmitting to EIA. EIA then combines and reformats the data from different users for use by analytical and reporting programs. PEDRO is available at no cost to the user. Formal training is not required since installation, data processing, and transmission are done by interactive, user-friendly menu options. The PEDRO system is divided into three functions: (1) data processing, (2) transmitting data to EIA, and (3) EIA processing. 28 figs.

  5. Arrhythmias and sudden death among older children and young adults following tetralogy of Fallot repair in the current era: are previously reported risk factors still applicable?

    Science.gov (United States)

    Arya, Swati; Kovach, Julie; Singh, Harinder; Karpawich, Peter P

    2014-01-01

    Young adult patients (pts) with repaired tetralogy of Fallot (TOF) remain at risk for arrhythmias (Ar) and sudden cardiac death (SCD). Based on past studies with earlier pt subsets, Ar/SCD events were associated with right ventricular (RV) systolic pressures >60 mm Hg, outflow tract gradients >20 mm Hg, and QRS duration >180 ms. However, there are limited recent studies to evaluate these risk factors in the current patient generation. Patients with TOF followed over the past 50 years were grouped by presence of any arrhythmias (group 1), absence of arrhythmias (group 2), and presence of SCD or significant ventricular arrhythmias (group 3) and correlated with current pt age, gender, age at repair, repair types, echocardiogram, cardiac magnetic resonance imaging, electrocardiogram/Holter, hemodynamics, and electrophysiology findings. Of 109 pts, 52 were male aged 17-58 years. Of these, 59 (54%) had Ar, two of whom had SCD. These 59 pts were chronologically older at the time of analysis, with repair at an older age and wider QRS duration (78-240, mean 158 ms) when compared with those without Ar. However, there was no correlation with surgical era, surgical repair, gender, RV pressure >60 mm Hg, right ventricular outflow tract gradient >20 mm Hg, or RV end-diastolic volume on CMRI. Ar/SCD risk continues to correlate with repair age and advancing pt age. QRS duration is longer in these patients but at a shorter interval (mean 158 ms) and less RV pressure (mean 43 mm Hg) than previously reported. In the current TOF patient generation, neither surgical era, type of repair, RV outflow gradient nor RV volume correlate with Ar/SCD. Electrophysiologic testing to verify and identify arrhythmias remains clinically effective. © 2013 Wiley Periodicals, Inc.

  6. Structural analysis of eight novel and 112 previously reported missense mutations in the interactive FXI mutation database reveals new insight on FXI deficiency.

    Science.gov (United States)

    Saunders, Rebecca E; Shiltagh, Nuha; Gomez, Keith; Mellars, Gillian; Cooper, Carolyn; Perry, David J; Tuddenham, Edward G; Perkins, Stephen J

    2009-08-01

    Factor XI (FXI) functions in blood coagulation. FXI is composed of four apple (Ap) domains and a serine protease (SP) domain. Deficiency of FXI leads to an injury-related bleeding disorder, which is remarkable for the lack of correlation between bleeding symptoms and FXI coagulant activity (FXI:C). The number of mutations previously reported in our interactive web database (http://www.FactorXI.org) is now significantly increased to 183 through our new patient studies and from literature surveys. Eight novel missense mutations give a total of 120 throughout the FXI gene (F11). The most abundant defects in FXI are revealed to be those from low-protein plasma levels (Type I: CRM-) that originate from protein misfolding, rather than from functional defects (Type II: CRM+). A total of 70 Ap missense mutations were analysed using a consensus Ap domain structure generated from the FXI dimer crystal structure. This showed that all parts of the Ap domain were affected. The 47 SP missense mutations were also distributed throughout the SP domain structure. The periphery of the Ap beta-sheet structure is sensitive to structural perturbation caused by residue changes throughout the Ap domain, yet this beta-sheet is crucial for FXI dimer formation. Residues located at the Ap4:Ap4 interface in the dimer are much less directly involved. We conclude that the abundance of Type I defects in FXI results from the sensitivity of the Ap domain folding to residue changes within this, and discuss how structural knowledge of the mutations improves our understanding of FXI deficiencies.

  7. DOD Electronic Commerce (EC)/Electronic Data Interchange (EDI) in contracting report

    Science.gov (United States)

    1993-12-01

    Use of Electronic Commerce (EC)/Electronic Data Interchange (EDI) to support Department of Defense (DoD) procurement processes has been under consideration for some time. A 1988 Deputy Secretary of Defense memo calls for maximum use of EDI, based on 10 years of DoD EDI investigation and experiments. In 1990, Defense Management Review Decision 941 stated, 'The strategic goal of DoD's current efforts is to provide the department with the capability to initiate, conduct, and maintain its external business related transactions and internal logistics, contracting, and financial activities without requiring the use of hard copy media.' The EC in Contracting PAT membership reflected a broad cross section of Military Services and Defense Agencies working on a full-time basis for 60 days. The diversity of the EC in Contracting PAT ensured that the needs and concerns of all DoD components were addressed during the creation of the report. The resultant plan, therefore, represents a comprehensive approach for implementing EC throughout the DoD.

  8. NASA wide electronic publishing system: Electronic printing and duplicating. Stage 3 evaluation report

    Science.gov (United States)

    Tuey, Richard C.; Moore, Fred W.; Ryan, Christine A.

    1995-01-01

    The report is presented in four sections: The Introduction describes the duplicating configuration under evaluation and the Background contains a chronological description of the evaluation segmented by phases 1 and 2. This section includes the evaluation schedule, printing and duplicating requirements, storage and communication requirements, electronic publishing system configuration, existing processes and proposed processes, billing rates, costs and productivity analysis, and the return on investment based upon the data gathered to date. The third section contains the phase 1 comparative cost and productivity analysis. This analysis demonstrated that LaRC should proceed with a 90-day evaluation of the DocuTech and follow with a phase 2 cycle to actually demonstrate that the proposed system would meet the needs of LaRC's printing and duplicating requirements, benchmark results, cost comparisons, benchmark observations, and recommendations. These are documented after the recommendations.

  9. Study of electron and neutrino interactions. Final report

    International Nuclear Information System (INIS)

    Abashian, A.

    1997-01-01

    This is the final report for the DOE-sponsored experimental particle physics program at Virginia Tech to study the properties of the Standard Model of strong and electroweak interactions. This contract (DE-AS05-80ER10713) covers the period from August 1, 1980 to January 31, 1993. Task B of this contract, headed by Professor Alexander Abashian, is described in this final report. This program has been pursued on many fronts by the researchers in a search for axions at SLAC, in electron-positron collisions in the AMY experiment at the TRISTAN collider in Japan, in measurements of muon decay properties in the MEGA and RHO experiments at the LAMPF accelerator, in a detailed analysis of scattering effects in the purported observation of a 17 keV neutrino at Oxford, in a search for a disoriented chiral condensate with the MiniMax experiment at Fermilab, and in an R ampersand D program on resistive plate counters that could find use in low-cost high-quality charged particle detection at low rates

  10. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; ET AL.

    2005-02-28

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linac. The highly successful development of an EBIS at BNL now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based pre-injectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The new RFQ and Linac that are used to accelerate beams from the EBIS to an energy sufficient for injection into the Booster are both very similar to existing devices already in operation at other facilities. Injection into the Booster will occur at the same location as the existing injection from the Tandem.

  11. 76 FR 49532 - Federal Motor Vehicle Safety Standards; Electronic Stability Control; Technical Report on the...

    Science.gov (United States)

    2011-08-10

    ...-0112] Federal Motor Vehicle Safety Standards; Electronic Stability Control; Technical Report on the Effectiveness of Electronic Stability Control Systems for Cars and LTVs AGENCY: National Highway Traffic Safety..., Electronic Stability Control Systems. The report's title is: Crash Prevention Effectiveness in Light-Vehicle...

  12. Ultraviolet Free Electron Laser Facility preliminary design report

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, I. (ed.)

    1993-02-01

    This document, the Preliminary Design Report (PDR) for the Brookhaven Ultraviolet Free Electron Laser (UV FEL) facility, describes all the elements of a facility proposed to meet the needs of a research community which requires ultraviolet sources not currently available as laboratory based lasers. Further, for these experiments, the requisite properties are not extant in either the existing second or upcoming third generation synchrotron light sources. This document is the result of our effort at BNL to identify potential users, determine the requirements of their experiments, and to design a facility which can not only satisfy the existing need, but have adequate flexibility for possible future extensions as need dictates and as evolving technology allows. The PDR is comprised of three volumes. In this, the first volume, background for the development of the proposal is given, including descriptions of the UV FEL facility, and representative examples of the science it was designed to perform. Discussion of the limitations and potential directions for growth are also included. A detailed description of the facility design is then provided, which addresses the accelerator, optical, and experimental systems. Information regarding the conventional construction for the facility is contained in an addendum to volume one (IA).

  13. Ultraviolet Free Electron Laser Facility preliminary design report

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1993-02-01

    This document, the Preliminary Design Report (PDR) for the Brookhaven Ultraviolet Free Electron Laser (UV FEL) facility, describes all the elements of a facility proposed to meet the needs of a research community which requires ultraviolet sources not currently available as laboratory based lasers. Further, for these experiments, the requisite properties are not extant in either the existing second or upcoming third generation synchrotron light sources. This document is the result of our effort at BNL to identify potential users, determine the requirements of their experiments, and to design a facility which can not only satisfy the existing need, but have adequate flexibility for possible future extensions as need dictates and as evolving technology allows. The PDR is comprised of three volumes. In this, the first volume, background for the development of the proposal is given, including descriptions of the UV FEL facility, and representative examples of the science it was designed to perform. Discussion of the limitations and potential directions for growth are also included. A detailed description of the facility design is then provided, which addresses the accelerator, optical, and experimental systems. Information regarding the conventional construction for the facility is contained in an addendum to volume one (IA)

  14. Electronic messaging between primary and secondary care: a four-year case report

    NARCIS (Netherlands)

    P.W. Moorman (Peter); P.J. Branger (Peter); W.J. van der Kam (Wouter); J. van der Lei (Johan)

    2001-01-01

    textabstractOBJECTIVE: To observe how electronic messaging between a hospital consultant and general practitioners (GPs) in 15 practices about patients suffering from diabetes evolved over a 3-year period after an initial 1-year study. DESIGN: Case report. Electronic

  15. Interaction Between Electrons, Magnons and Phonons in Nickel. RCN Report

    International Nuclear Information System (INIS)

    Frikkee, E.

    1971-02-01

    By means of inelastic neutron scattering, a localized electron excitation was observed in Ni and (4% Fe). The excitation interacts with magnons and phonons, and is assumed to correspond with transitions between the nearly-degenerate electronstates Δ 6 ↑ and Δ 7 ↑ near X, which are situated just below the Fermi level.Selection rules for electron-phonon and electronmagnon scattering are determined by means of group theory. It is found that in particular the transverse (Δ 5 ) phonons in the [100] direction are perturbed. The observed neutron-electron scattering turns out to be an indirect process, which is only possible due to the interaction between the (Δ 6 , Δ 7 ) electrons and the lattice. The basic mechanism for the observed effects is the electron spin-orbit coupling, which establishes the interaction between the electron spin system and the lattice. (author)

  16. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; GRANDINETTI, R.; HSEUH, H.; JAVIDFAR, A.; KPONOU, A.; LAMBIASE, R.; LESSARD, E.; LOCKEY, R.; LODESTRO, V.; MAPES, M.; MIRABELLA, D.; NEHRING, T.; OERTER, B.; PENDZICK, A.; PIKIN, A.; RAPARIA, D.; RITTER, J.; ROSER, T.; RUSSO, T.; SNYDSTRUP, L.; WILINSKI, M.; ZALTSMAN, A.; ZHANG, S.

    2005-09-01

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linear accelerator (Linac). The highly successful development of an EBIS at Brookhaven National Laboratory (BNL) now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based preinjectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The proposed pre-injector system would also provide for a major enhancement in capability for the NASA Space Radiation Laboratory (NSRL), which utilizes heavy-ion beams from the RHIC complex. EBIS would allow for the acceleration of all important ion species for the NASA radiobiology program, such as, helium, argon, and neon which are unavailable with the present Tandem injector. In addition, the new system would allow for very rapid switching of ion species for

  17. A diagnostic dilemma: Left-sided appendicitis in a 10 year old boy with previously undiagnosed intestinal malrotation. A case report

    Directory of Open Access Journals (Sweden)

    Ashvini Shekhar

    2015-01-01

    Conclusion: Left sided acute appendicitis is a diagnostic dilemma, thus often leading to management delays. It is pertinent to remember that malrotation of the gut is more common than previously thought, and not just a disease of infancy. It is advisable to consider imaging studies while balancing the risk-benefit-ratio of radiation exposure, especially in paediatric cases to cinch the diagnosis.

  18. Laparoscopy After Previous Laparotomy

    Directory of Open Access Journals (Sweden)

    Zulfo Godinjak

    2006-11-01

    Full Text Available Following the abdominal surgery, extensive adhesions often occur and they can cause difficulties during laparoscopic operations. However, previous laparotomy is not considered to be a contraindication for laparoscopy. The aim of this study is to present that an insertion of Veres needle in the region of umbilicus is a safe method for creating a pneumoperitoneum for laparoscopic operations after previous laparotomy. In the last three years, we have performed 144 laparoscopic operations in patients that previously underwent one or two laparotomies. Pathology of digestive system, genital organs, Cesarean Section or abdominal war injuries were the most common causes of previouslaparotomy. During those operations or during entering into abdominal cavity we have not experienced any complications, while in 7 patients we performed conversion to laparotomy following the diagnostic laparoscopy. In all patients an insertion of Veres needle and trocar insertion in the umbilical region was performed, namely a technique of closed laparoscopy. Not even in one patient adhesions in the region of umbilicus were found, and no abdominal organs were injured.

  19. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    Science.gov (United States)

    Rothgeb, Matt; Kessel, Kurt

    2013-01-01

    The overall objective of the Hexavalent Chrome Free Coatings for Electronics Applications project is to evaluate and test pretreatments not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  20. Generation of complete electronic nuclear medicine reports including static, dynamic and gated images

    International Nuclear Information System (INIS)

    Beretta, M.; Pilon, R.; Mut, F.

    2002-01-01

    Aim: To develop a procedure for the creation of nuclear medicine reports containing static and dynamic images. The reason for implementing this technique is the lack of adequate solutions for an electronic format of nuclear medicine results allowing for rapid transmission via e-mail, specially in the case of dynamic and gated SPECT studies, since functional data is best presented in dynamic mode. Material and Methods: Clinical images were acquired in static, whole body, dynamic and gated mode, corresponding to bone studies, diuretic renogram, radionuclide cystography and gated perfusion SPECT, as well as respective time-activity curves. Image files were imported from a dedicated nuclear medicine computer system (Elscint XPert) to a Windows-based PC through a standard ethernet network with TCP-IP communications protocol, using a software developed by us which permits the conversion from the manufacturer's original format into a bitmap format (.bmp) compatible with commercially available PC software. For cardiac perfusion studies, background was subtracted prior to transferring to reduce the amount of information in the file; this was not done for other type of studies because useful data could be eliminated. Dynamic images were then processed using commercial software to create animated files and stored in .gif format. Static images were re-sized and stored in .jpg format. Original color or gray scale was always preserved. All the graphic material was then merged with a previously prepared report text using HTML format. The report also contained reference diagrams to facilitate interpretation. The whole report was then compressed into a self-extractable file, ready to be sent by electronic mail. Reception of the material was visually checked for data integrity including image quality by two experienced nuclear medicine physicians. Results: The report presented allows for simultaneous visualization of the text, diagrams and images either static, dynamic, gated or

  1. 77 FR 10373 - Greenhouse Gas Reporting Program: Electronics Manufacturing: Revisions to Heat Transfer Fluid...

    Science.gov (United States)

    2012-02-22

    ... Greenhouse Gas Reporting Program: Electronics Manufacturing: Revisions to Heat Transfer Fluid Provisions... technical revisions to the electronics manufacturing source category of the Greenhouse Gas Reporting Rule... final rule will also be available through the WWW on the EPA's Greenhouse Gas Reporting Program Web site...

  2. 5 CFR 2604.601 - Electronic posting and submission of annual OGE FOIA report.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Electronic posting and submission of annual OGE FOIA report. 2604.601 Section 2604.601 Administrative Personnel OFFICE OF GOVERNMENT ETHICS... FINANCIAL DISCLOSURE REPORTS Annual OGE FOIA Report § 2604.601 Electronic posting and submission of annual...

  3. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  4. Electron-dislocation interaction at low temperatures. Progress report

    International Nuclear Information System (INIS)

    1976-01-01

    Studies of the interaction of mobile dislocations with electrons have shown that dislocation motion can be, in part, described by treating the dislocation as an underdamped oscillator. In particular, studies in lead alloys have shown tht dislocation motion can be considered as the motion of string, slightly damped by electrons, without regard for any other lattice friction. In addition we have shown that silver solutes, in lead crystals, occupy, partially, interstitial sites. Finally, we have shown that dislocations in copper interact, unexpectedly, with electrons. This is shown by measuring the influence of a magnetic field on the flow stress of copper crystals at 4.2 0 K

  5. HMI Data Processing and Electronics Departmenmt. Scientific report 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The Data Processing and Electronics Department carries out application-centered R+D work in the fields of general and process-related data processing, digital and analog measuring systems, and electronic elements. As part of the HMI infrastructure, the Department carries out central data processing and electronics functions. The R+D activities of the Department and its infrastructural tasks were carried out in seven Working Groups and one Project Group: Computer systems; Mathematics and graphical data processing; Software developments; Process computer systems, hardware; Nuclear electronics, measuring and control systems; Research on structural elements and irradiation testing; Computer center and cooperation in the 'Central Project Leader Group of the German Research Network' (DFN). (orig./RB) [de

  6. Annual report of the group for maintenance of electronic equipment

    International Nuclear Information System (INIS)

    Popovic, B.

    1965-01-01

    Maintenance and repair of the RA reactor control and safety systems were uniformly distributed during the whole year and were done according to the annual plan. A series of repairs of he electronic equipment as well as exchange of electronic components and elec tonic tubes. The testing and calibration of control and protection circuits were done regularly according to the needs and operation state of the reactor and according to the instructions. Inspections, repairs and reconstructions well as operating characteristics of individual elements as well as complete electronic circuits during 1965 have shown da the systems of control and safety are still in good condition. Somewhat higher number of failures due to aging of electronic tubes is a regular consequence of equipment and instrumentation aging [sr

  7. De novo adamantinomatous craniopharyngioma presenting anew in an elderly patient with previous normal CT and MRI studies: A case report and implications on pathogenesis

    Directory of Open Access Journals (Sweden)

    Amy Walker, B.S.

    2015-09-01

    Full Text Available Adamantinomatous craniopharyngiomas are histologically benign epithelial tumors which arise from embryonic remnants of the craniopharyngeal duct and Rathke’s pouch. They are thought to have a congenital origin and are histologically unique from papillary craniopharyngioma. We describe the case of an elderly male who presented with symptoms related to a large craniopharyngioma with previously normal brain magnetic resonance and computed tomography imaging studies. These findings dispute the embryogenic theory that craniopharyngiomas observed in adults develop from the persistent slow growth of embryonic remnants.

  8. Application of the electromagnetic borehole flowmeter and evaluation of previous pumping tests at Paducah Gaseous Diffusion Plant. Final report, June 15, 1992--August 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Young, S.C.; Julian, S.C.; Neton, M.J.

    1993-01-01

    Multi-well pumping tests have been concluded at wells MW79, MW108, and PW1 at the Paducah Gaseous Diffusion Plant (PGDP) to determine the hydraulic properties of the Regional Gravel Aquifer (RGA). Soil cores suggest that the RGA consists of a thin sandy facies (2 to 6 feet) at the top of a thicker (> 10 feet) gravelly facies. Previous analyses have not considered any permeability contrast between the two facies. To assess the accuracy of this assumption, TVA personnel conducted borehole flowmeter tests at wells MW108 and PW1. Well MW79 could not be tested. The high K sand unit is probably 10 times more permeable than comparable zone in the gravelly portion of the RGA. Previous analyses of the three multi-well aquifer tests do not use the same conceptual aquifer model. Data analysis for one pumping test assumed that leakance was significant. Data analysis for another pumping test assumed that a geologic boundary was significant. By collectively analyzing all three tests with the borehole flowmeter results, the inconsistency among the three pumping tests can be explained. Disparity exists because each pumping test had a different placement of observation wells relative to the high K zone delineating by flowmeter testing.

  9. Previous ISD Program Review.

    Science.gov (United States)

    1981-03-01

    report. The detail required for such a review would be unwieldy and would comsume inordinate amounts of time. The result of the document review will...attempts have been made at writing specific behavioral objectives (SBOs). These, however, have proven to be inadequate in that they are not stated in... behavioral terms (e.g., "will understand," "will have a knowledge of," etc.). C. Development of CRO/CRTs? In nearly all cases, ISD teams are just

  10. 40 CFR 3.2 - How does this part provide for electronic reporting?

    Science.gov (United States)

    2010-07-01

    ... electronic document provided that the state, tribe, or local government seeks and obtains revision or... electronic reporting. (2) A state, tribe, or local government that is applying for initial delegation... obligate EPA, states, tribes, or local governments to accept electronic documents. ...

  11. Two case reports: Carcinoma of the cervix and carcinoma of the endometrium treated with radiotherapy after previous irradiation for benign uterine bleeding

    Energy Technology Data Exchange (ETDEWEB)

    MacLeod, C. [Royal Prince Alfred Hospital, Camperdown, NSW (Australia). Department of Radiation Oncology

    1998-08-01

    In the 1940s, 1950s and 1960s, low doses of radiotherapy were used to treat benign uterine bleeding. The cases of two women who received this form of therapy and later developed gynaecological malignancies and had high-dose pelvic radiotherapy are presented. A 76-year-old woman with an International Federation of Gynecology and Obstetrics (FIGO) stage-II B squamous cell carcinoma of the cervix received external beam radiotherapy and intra-uterine brachytherapy and a 77-year-old woman with a FIGO stage-I B endometrial adenocarcinoma received adjuvant postoperative pelvic radiotherapy. Both women had a significant past history of low-dose-rate intra-uterine irradiation for dysfunctional uterine bleeding. Therefore the theoretical question of carcinogenesis was raised, and also the practical questions of what dose had previously been given and what further dose could be safely given with regard to normal tissue tolerance. Copyright (1998) Blackwell Science Pty Ltd 20 refs.

  12. Two case reports: Carcinoma of the cervix and carcinoma of the endometrium treated with radiotherapy after previous irradiation for benign uterine bleeding

    International Nuclear Information System (INIS)

    MacLeod, C.

    1998-01-01

    In the 1940s, 1950s and 1960s, low doses of radiotherapy were used to treat benign uterine bleeding. The cases of two women who received this form of therapy and later developed gynaecological malignancies and had high-dose pelvic radiotherapy are presented. A 76-year-old woman with an International Federation of Gynecology and Obstetrics (FIGO) stage-II B squamous cell carcinoma of the cervix received external beam radiotherapy and intra-uterine brachytherapy and a 77-year-old woman with a FIGO stage-I B endometrial adenocarcinoma received adjuvant postoperative pelvic radiotherapy. Both women had a significant past history of low-dose-rate intra-uterine irradiation for dysfunctional uterine bleeding. Therefore the theoretical question of carcinogenesis was raised, and also the practical questions of what dose had previously been given and what further dose could be safely given with regard to normal tissue tolerance. Copyright (1998) Blackwell Science Pty Ltd

  13. HIGH VOLTAGE ENVIRONMENTAL APPLICATIONS, INC.ELECTRON BEAM TECHNOLOGY - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    Science.gov (United States)

    This report evaluates a high-voltage electron beam (E-beam) technology's ability to destroy volatile organic compounds (VOCs) and other contaminants present in liquid wastes. Specifically, this report discusses performance and economic data from a Superfund Innovative Technology...

  14. The use of porcine small intestinal submucosa mesh (SURGISIS as a pelvic sling in a man and a woman with previous pelvic surgery: two case reports

    Directory of Open Access Journals (Sweden)

    Al-Sahaf Osama

    2009-02-01

    Full Text Available Abstract Introduction Closing the pelvic peritoneum to prevent the small bowel dropping into the pelvis after surgery for locally recurrent rectal cancer is important to prevent adhesions deep in the pelvis or complications of adjuvant radiotherapy. Achieving this could be difficult because sufficient native tissue is unavailable; we report on the use of small intestine submucosa extra-cellular matrix mesh in the obliteration of the pelvic brim. Case presentation We describe two cases in which submucosa extra-cellular matrix mesh was used to obliterate the pelvic brim following resection of a recurrent rectal tumour; the first patient, a 78-year-old Caucasian man, presented with small bowel obstruction caused by adhesions to a recurrent rectal tumour. The second patient, an 84-year-old Caucasian woman, presented with vaginal discharge caused by an entero-vaginal fistula due to a recurrent rectal tumour. Conclusion We report on the use of submucosa extra-cellular matrix mesh as a pelvic sling in cases where primary closure of the pelvic peritoneum is unfeasible. Its use had no infective complications and added minimal morbidity to the postoperative period. This is an original case report that would be of interest to general and colorectal surgeons.

  15. Biennial report for 1982 and 1983 of Electronics Division

    International Nuclear Information System (INIS)

    1985-01-01

    The research and development activities of the Electronics Division of the Bhabha Atomic Research Centre, Bombay during the years 1982 and 1983 is presented in the form of individual summaries arranged under the headings: reactor instrumentations, nuclear instruments, medical instrumentation, local area network, general instruments. Other activities of the Division such as servicing of electronic equipments, provision of wiring and PCB facilities to computer network and micro based systems, training etc are also decribed in brief. A list of staff-members is given at the end. (author)

  16. 77 FR 12367 - Agency Information Collection and Reporting Activities; Electronic Filing of Bank Secrecy Act...

    Science.gov (United States)

    2012-02-29

    ... capability of electronically filing BSA reports through its system called BSA E-Filing. Effective August 2011... Accounts (FBAR) report. BSA E-Filing is a secure, web-based electronic filing system. It is a flexible... filing institutions or individuals, thereby providing a significant improvement in data quality. BSA E...

  17. Four Forensic Entomology Case Studies: Records and Behavioral Observations on Seldom Reported Cadaver Fauna With Notes on Relevant Previous Occurrences and Ecology.

    Science.gov (United States)

    Lindgren, Natalie K; Sisson, Melissa S; Archambeault, Alan D; Rahlwes, Brent C; Willett, James R; Bucheli, Sibyl R

    2015-03-01

    A yearlong survey of insect taxa associated with human decomposition was conducted at the Southeast Texas Applied Forensic Science (STAFS) facility located in the Center for Biological Field Studies of Sam Houston State University in Huntsville, TX. During this study, four insect-cadaver interactions were observed that represent previously poorly documented yet forensically significant interactions: Syrphidae maggots colonized a corpse in an aquatic situation; Psychodidae adults mated and oviposited on an algal film that was present on a corpse that had been recently removed from water; several Panorpidae were the first insects to feed upon a freshly placed corpse in the autumn; and a noctuid caterpillar was found chewing and ingesting dried human skin. Baseline knowledge of insect-cadaver interactions is the foundation of forensic entomology, and unique observations have the potential to expand our understanding of decomposition ecology. © The Author 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. FY2009 Annual Progress Report for Advanced Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Susan A. [Dept. of Energy (DOE), Washington DC (United States)

    2010-01-01

    The Advanced Power Electronics and Electric Machines (APEEM) subprogram within the Vehicle Technologies Program provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on understanding and improving the way the various new components of tomorrow's automobiles will function as a unified system to improve fuel efficiency.

  19. Electron-dislocation interaction at low temperatures. Progress report

    International Nuclear Information System (INIS)

    1978-01-01

    The interaction of mobile dislocations with electrons in copper and copper alloys has shown that dislocation motion in copper, at low temperature, can be treated as an analog of an underdamped oscillator. We have also shown that the viscous drag on mobile dislocations in type II superconductors can be treated as an acoustic attenuation of an elastic wave

  20. The Skills Implications of Electronic Retailing. IES Final Report.

    Science.gov (United States)

    Tackey, Nii Djan; Hillage, Jim; Jagger, Nick; Bates, Peter

    The skills and education/training implications of the development of electronic commerce in the United Kingdom's retail industry and its associated supply chain were examined. The major data collection activities were as follows: a literature review; consultation with leading academics and advisers; an e-mail-based call for information from…

  1. Radial electron beam laser excitation: the REBLE report

    International Nuclear Information System (INIS)

    Ramirez, J.J.; Prestwich, K.R.

    1978-10-01

    The results of an investigation of techniques to generate high-power radially converging electron beams and the application of these beams to gas lasers is discussed. The design and performance of the REBLE accelerator that was developed for this program is presented. Reliable operation of the radial diode has been obtained at levels up to 1 MV, 200 kA, and 20 ns. It has been demonstrated that the anode current density can be made uniform to better than 15% over 1000 cm 2 areas with 100 to 250 A/cm 2 intensities. The measured total and spatially resolved energy deposition of this radial electron beam in various gases is compared with Monte Carlo calculations. In most cases, these codes give an accurate description of the beam transport and energy deposition. With the electron beam pumping xenon gas, the amplitude of xenon excimer radiation (1720 A 0 ) was radially uniform to within the experimental uncertainty. The efficiency of converting deposited electron beam energy to xenon excimer radiation was 20%

  2. The Electronic Presentation: A Status Report of International Use.

    Science.gov (United States)

    Griffin, Robert E.; And Others

    This paper describes how electronic presentations are currently used by business people. Business people in the United States and Sweden were surveyed to determine how they are using the medium. A questionnaire was mailed to 506 business people in the United States (201 returned) and to 80 business people in Sweden (76 returned). Results are…

  3. Homozygous loss of function BRCA1 variant causing a Fanconi-anemia-like phenotype, a clinical report and review of previous patients.

    Science.gov (United States)

    Freire, Bruna L; Homma, Thais K; Funari, Mariana F A; Lerario, Antônio M; Leal, Aline M; Velloso, Elvira D R P; Malaquias, Alexsandra C; Jorge, Alexander A L

    2018-03-01

    Fanconi Anemia (FA) is a rare and heterogeneous genetic syndrome. It is associated with short stature, bone marrow failure, high predisposition to cancer, microcephaly and congenital malformation. Many genes have been associated with FA. Previously, two adult patients with biallelic pathogenic variant in Breast Cancer 1 gene (BRCA1) had been identified in Fanconi Anemia-like condition. The proband was a 2.5 year-old girl with severe short stature, microcephaly, neurodevelopmental delay, congenital heart disease and dysmorphic features. Her parents were third degree cousins. Routine screening tests for short stature was normal. We conducted whole exome sequencing (WES) of the proband and used an analysis pipeline to identify rare nonsynonymous genetic variants that cause short stature. We identified a homozygous loss-of-function BRCA1 mutation (c.2709T > A; p. Cys903*), which promotes the loss of critical domains of the protein. Cytogenetic study with DEB showed an increased chromosomal breakage. We screened heterozygous parents of the index case for cancer and we detected, in her mother, a metastatic adenocarcinoma in an axillar lymph node with probable primary site in the breast. It is possible to consolidate the FA-like phenotype associated with biallelic loss-of-function BRCA1, characterized by microcephaly, short stature, developmental delay, dysmorphic face features and cancer predisposition. In our case, the WES allowed to establish the genetic cause of short stature in the context of a chromosome instability syndrome. An identification of BRCA1 mutations in our patient allowed precise genetic counseling and also triggered cancer screening for the patient and her family members. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Feline leprosy due to Candidatus 'Mycobacterium lepraefelis': Further clinical and molecular characterisation of eight previously reported cases and an additional 30 cases.

    Science.gov (United States)

    O'Brien, Carolyn R; Malik, Richard; Globan, Maria; Reppas, George; McCowan, Christina; Fyfe, Janet A

    2017-09-01

    This paper, the last in a series of three on 'feline leprosy', provides a detailed description of disease referable to the previously unnamed species, Candidatus 'Mycobacterium lepraefelis', a close relative of the human pathogens Mycobacterium leprae and Mycobacterium lepromatosis. Cases were sourced retrospectively and prospectively for this observational study, describing clinical, geographical and molecular microbiological data for cats definitively diagnosed with Candidatus 'M lepraefelis' infection. A total of 145 cases of feline leprosy were scrutinised; 114 'new' cases were sourced from the Victorian Infectious Diseases Reference Laboratory (VIDRL) records, veterinary pathology laboratories or veterinarians, and 31 cases were derived from six published studies. Thirty-eight cats were definitively diagnosed with Candidatus 'M lepraefelis' infection. Typically, cats tended to be middle-aged or older when first infected, with a male predilection. Affected cats typically had widespread cutaneous lesions, in some cases after initially localised disease. Advanced cases were often systemically unwell. All cats had outdoor access. The histological picture was lepromatous in the majority of patients, although two cases had tuberculoid disease. In one case that underwent necropsy, lesions were evident in the liver, spleen and lungs. Treatment was varied, although most cats received a combination of oral clarithromycin and rifampicin. Prognosis for recovery was variable, but typically poor. Candidatus 'M lepraefelis' typically causes high bacterial index (lepromatous) feline leprosy that in some cases progresses to systemic mycobacteriosis. The disease has a variable clinical course and prognosis. Many cases either died or were euthanased due to the infection. Multilocus sequence analysis reveals a heterogeneous picture and further analysis of draft genome sequencing may give clues to the taxonomy and epidemiology of this organism. Prospective treatment trials and

  5. Majewski osteodysplastic primordial dwarfism type II (MOPD II) syndrome previously diagnosed as Seckel syndrome: report of a novel mutation of the PCNT gene.

    Science.gov (United States)

    Piane, Maria; Della Monica, Matteo; Piatelli, Gianluca; Lulli, Patrizia; Lonardo, Fortunato; Chessa, Luciana; Scarano, Gioacchino

    2009-11-01

    We report on a 3-year-old boy with prenatal onset of proportionate dwarfism, postnatal severe microcephaly, high forehead with receded hairline, sparse scalp hair, beaked nose, mild retrognathia and hypotonia diagnosed at birth as Seckel syndrome. At age 3 years, he became paralyzed due to a cerebrovascular malformation. Based on the clinical and radiological features showing evidence of skeletal dysplasia, the diagnosis was revised to Majewski osteodysplastic primordial dwarfism type II (MOPD II) syndrome. Western blot analysis of the patient's lymphoblastoid cell line lysate showed the absence of the protein pericentrin. Subsequent molecular analysis identified a novel homozygous single base insertion (c.1527_1528insA) in exon 10 of the PCNT gene, which leads to a frameshift (Treo510fs) and to premature protein truncation. PCNT mutations must be considered diagnostic of MOPD II syndrome. A possible role of pericentrin in the development of cerebral vessels is suggested. Copyright 2009 Wiley-Liss, Inc.

  6. Radiation port cutaneous metastases: Reports of two patients whose recurrent visceral cancers presented as skin lesions at the site of previous radiation and literature review

    Directory of Open Access Journals (Sweden)

    Brian Spencer Hoyt

    2014-01-01

    Full Text Available Radiation therapy is associated with a variety of complications, including the development of primary skin cancers in the radiated region. However, it is rare for patients with visceral cancers who are treated with radiation therapy to subsequently develop cutaneous metastasis within the radiation port. We describe two patients with internal malignancies who developed cutaneous metastases within their radiation ports following radiotherapy. In addition, we used PubMed to perform an extensive literature review and identify additional reports of cutaneous metastasis within a radiation port. We excluded patients who developed melanoma or primary skin cancers in the radiation port. We also excluded patients with non-solid organ malignancies. Herein, we summarize the characteristics of 23 additional patients who experienced radiation port cutaneous metastases and explore possible mechanisms for the occurrence of radiation port cutaneous metastases.

  7. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  8. Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report

    International Nuclear Information System (INIS)

    Nation, J.A.

    1996-01-01

    The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives

  9. Power Electronics Thermal Management R&D: Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Gilbert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-04-08

    The objective for this project is to develop thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter). Device- and system-level thermal analyses are conducted to determine the thermal limitations of current automotive power modules under elevated device temperature conditions. Additionally, novel cooling concepts and material selection will be evaluated to enable high-temperature silicon and WBG devices in power electronics components. WBG devices (silicon carbide [SiC], gallium nitride [GaN]) promise to increase efficiency, but will be driven as hard as possible. This creates challenges for thermal management and reliability.

  10. Power Electronics Thermal Management Research: Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Gilberto [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-19

    The objective for this project is to develop thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter). Reliable WBG devices are capable of operating at elevated temperatures (≥ 175 °Celsius). However, packaging WBG devices within an automotive inverter and operating them at higher junction temperatures will expose other system components (e.g., capacitors and electrical boards) to temperatures that may exceed their safe operating limits. This creates challenges for thermal management and reliability. In this project, system-level thermal analyses are conducted to determine the effect of elevated device temperatures on inverter components. Thermal modeling work is then conducted to evaluate various thermal management strategies that will enable the use of highly efficient WBG devices with automotive power electronic systems.

  11. Final Technical Report: Electronic Structure Workshop (ES13)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shiwei [College of William and Mary, Williamsburg, VA (United States)

    2015-02-26

    The 25th Annual Workshop on Recent Developments in Electronic Structure Methods (ES2013) was successfully held at the College of William & Mary in Williamsburg VA on June 11-14, 2013. The workshop website is at http://es13.wm.edu/ , which contains updated information on the workshop and a permanent archive of the scientific contents. DOE's continued support has been instrumental to the success of the workshop.

  12. CEBAF [Continuous Electron Beam Accelerator Facility] design report

    International Nuclear Information System (INIS)

    1986-05-01

    This book describes the conceptual design of, and the planning for, the Continuous Electron Beam Accelerator Facility (CEBAF), which will be a high-intensity, continuous-wave electron linear accelerator (linac) for nuclear physics. Its principal scientific goal is to understand the quark structure, behavior, and clustering of individual nucleons in the nuclear medium, and simultaneously to understand the forces governing this behavior. The linac will consist of 1 GeV of accelerating structure, split into two antiparallel 0.5-GeV segments. The segments will be connected by a beam transport system to circulate the electron beams from one segment to the other for up to four complete passes of acceleration. The maximum beam energy will be 4 GeV at a design current of 200 microamperes. The accelerator complex will also include systems to extract three continuous beams from the linac and to deliver them to three experimental halls equipped with detectors and instrumentation for nuclear physics research. The accelerating structure will be kept superconducting within insulated cryostats filled with liquid helium produced at a central helium refrigerator and distributed to the cryostats via insulated transfer lines. An injector, instrumentation and controls for the accelerator, radio-frequency power systems, and several support facilities will also be provided. A cost estimate based on the Work Breakdown Structure has been completed. Assuming a five-year construction schedule starting early in FY 1987, the total estimated cost is $236 million (actual year dollars), including contingency

  13. Electronic Patient Reported Outcomes in Paediatric Oncology - Applying Mobile and Near Field Communication Technology.

    Science.gov (United States)

    Duregger, Katharina; Hayn, Dieter; Nitzlnader, Michael; Kropf, Martin; Falgenhauer, Markus; Ladenstein, Ruth; Schreier, Günter

    2016-01-01

    Electronic Patient Reported Outcomes (ePRO) gathered using telemonitoring solutions might be a valuable source of information in rare cancer research. The objective of this paper was to develop a concept and implement a prototype for introducing ePRO into the existing neuroblastoma research network by applying Near Field Communication and mobile technology. For physicians, an application was developed for registering patients within the research network and providing patients with an ID card and a PIN for authentication when transmitting telemonitoring data to the Electronic Data Capture system OpenClinica. For patients, a previously developed telemonitoring system was extended by a Simple Object Access Protocol (SOAP) interface for transmitting nine different health parameters and toxicities. The concept was fully implemented on the front-end side. The developed application for physicians was prototypically implemented and the mobile application of the telemonitoring system was successfully connected to OpenClinica. Future work will focus on the implementation of the back-end features.

  14. Resolution of temporomandibular joint dysfunction (TMJD) by correcting a lateral head translation posture following previous failed traditional chiropractic therapy: a CBP® case report.

    Science.gov (United States)

    Jaeger, Jason O; Oakley, Paul A; Moore, Robert R; Ruggeroli, Edward P; Harrison, Deed E

    2018-01-01

    [Purpose] To present the case of the resolution of right temporomandibular joint dysfunction (TMJD) following the correction of a right lateral head translation posture. [Subject and Methods] A 24 year old female reported facial pain and jaw clicking in the right TMJ. Radiography revealed a 19 mm right head (shift) translation posture. TMJ vibration analysis showed characteristic abnormalities for the right TMJ. The patient was treated with CBP ® technique mirror image ® left sided exercises, and traction methods as well as spinal manipulative therapy (SMT). [Results] After 36 treatments over a 12-week time period, a complete correction of the lateral head posture was achieved corresponding with a complete resolution of jaw pain and clicking. TMJ vibration analysis demonstrated normal right side TMJ characteristics following treatment. [Conclusion] Abnormal head/neck postures, such as lateral head translation, may be an unrealized source of TMJD and may be explained through the 'regional interdependence' model or by how seemingly unrelated anatomy may be associated with a primary complaint.

  15. High-pressure electron-resonance studies of electronic, magnetic, and structural phase transitions. Progress report

    International Nuclear Information System (INIS)

    Pifer, J.H.; Croft, M.C.

    1983-01-01

    Research is described in development of a high-pressure electron-resonance probe capable of operating down to 1.5 0 K temperatures. The apparatus has been used to measure the EPR of a sample of DPPH at room temperature and zero pressure. EPR has been used to measure valence field instabilities in alloy systems. Studies have been done on metal-insulator transitions at high pressure, and are briefly described

  16. Final Report on Investigation of the Electron Interactions in Graphene

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Philip [Columbia University

    2015-02-14

    In graphene, combined with the real spin degree of freedom, which exhibits SU(2) symmetry, the total internal degrees of freedom of graphene carriers is thus described by a larger SU(4) symmetry, which produces a richer space for potential phenomena of emergent correlated electron phenomena. The major part of this proposal is exploring this unique multicomponent correlated system in the quantum limit. In the current period of DOE BES support we have made several key advances that will serve as a foundation for the new studies in this proposal. Employing the high-mobility encapsulated graphene heterostructures developed during the current phase of research, we have investigated spin and valley quantum Hall ferromagnetism in graphene and discovered a spin phase transition leading to a quantum spin Hall analogue. We have also observed the fractal quantum Hall effect arising from the Hofstadter’s butterfly energy spectrum. In addition, we have discovered multiband transport phenomena in bilayer graphene at high carrier densities.

  17. Electronic instrument for radon daughter dosimetry. Report of investigations

    International Nuclear Information System (INIS)

    Durkin, J.

    1977-01-01

    Due to the daily exposures of uranium mining personnel to 222Rn daughters, a device is needed which will continually monitor the individual's exposure. Such a device has been built and tested and is known as the Radon Daughter Dosimeter. This is an electronic instrument using a solid-state detector and circuitry. The system permits the evaluation of cumulative exposures to airborne radon progeny, expressed in units of Working Level Hours (WL-HRS). The instrument is a personal device worn by the individual throughout the working shift. Since the instrument is in close proximity to the miner and measures continual exposure, it provides an accurate account of total cumulative exposure, thus avoiding the errors caused by the present technique of spot checking of the environment

  18. Final Technical Report for Photovoltaic Power Electronics Research Initiative (PERI)

    Energy Technology Data Exchange (ETDEWEB)

    Amirahmadi, Ahmadreza [Univ. of Central Florida, Orlando, FL (United States); Jordan, Charlie [Univ. of Central Florida, Orlando, FL (United States); batarseh, Issa [Univ. of Central Florida, Orlando, FL (United States)

    2015-08-31

    The Power Electronics team at the University of Central Florida (UCF) has developed a novel three-phase micro-inverter for photovoltaic (PV) distributed applications. Based on a new advanced topology and control methodology, the developed inverter is small in size, and achieved DoE targeted power density, cost and efficiency specifications. Today’s inverters are widely used in PV based energy harvesting systems, but are based on single-phase design with limited application to large installations. These micro-inverters have been shown to have advantageous over their string inverter counterparts in both grid-tied PV energy harvesting and standalone micro-grid systems with energy storage. Some of these are simplified installation, no high voltage DC wiring, no single point of failure and improved energy harvesting. Several patents have been issued and this new solar conversion technology has been licensed to the private sector.

  19. RLE (Research Laboratory of Electronics) Progress Report Number 129.

    Science.gov (United States)

    1987-01-01

    27709 ELEMENT NO. NO. NO. NO. 1. TITLE finciade SeciantV Ciiiiiiificationt Progress Report.No. 129 12. PERSONAL AUTHORI(S) Jonathan Allen, Daniel...TMIS PAGE *~ ~ d 1 ". d4 ’V. ~a PI al . 1 AN *,.i **N %** RLE Progress Report No. 129 January 1987 Submitted by: Prof. Jonathan Allen Prof. Daniel...Clevenger, J. Floro, S.M. Garrison, J. Im, K. Ismail, H. Kahn, H.J. Kim, Y.C. Ku, J.C. Licini, U. Meirav, J.E. Palmer, S.L. Park, H.M. Quek , J. Scott

  20. NASAwide electronic publishing system-prototype STI electronic document distribution: Stage-4 evaluation report. Part 2; Appendices

    Science.gov (United States)

    Tuey, Richard C.; Collins, Mary; Caswell, Pamela; Haynes, Bob; Nelson, Michael L.; Holm, Jeanne; Buquo, Lynn; Tingle, Annette; Cooper, Bill; Stiltner, Roy

    1996-01-01

    This evaluation report contains an introduction, seven chapters, and five appendices. The Introduction describes the purpose, conceptual framework, functional description, and technical report server of the Scientific and Technical Information (STI) Electronic Document Distribution (EDD) project. Chapter 1 documents the results of the prototype STI EDD in actual operation. Chapter 2 documents each NASA center's post processing publication processes. Chapter 3 documents each center's STI software, hardware. and communications configurations. Chapter 7 documents STI EDD policy, practices, and procedures. The appendices consist of (A) the STI EDD Project Plan, (B) Team members, (C) Phasing Schedules, (D) Accessing On-line Reports, and (E) Creating an HTML File and Setting Up an xTRS. In summary, Stage 4 of the NASAwide Electronic Publishing System is the final phase of its implementation through the prototyping and gradual integration of each NASA center's electronic printing systems, desk top publishing systems, and technical report servers, to be able to provide to NASA's engineers, researchers, scientists, and external users, the widest practicable and appropriate dissemination of information concerning its activities and the result thereof to their work stations.

  1. The chirped-pulse free-electron laser: Final technical report, September 1987--October 1988

    International Nuclear Information System (INIS)

    Moore, G.T.

    1989-01-01

    This is the final report of a theoretical and numerical investigation into the operation of pulsed free-electron lasers in which the electron energy depends on the time of injection into the wiggler. Such energy ''chirping'' over each of a train of electron micropulses injected into an FEL oscillator is expected to give rise to a laser pulse inside the optical resonator with a chirped carrier frequency ω/sub s/(/tau/). 8 refs., 7 figs

  2. Piloting a national laboratory electronic programme status reporting ...

    African Journals Online (AJOL)

    All data were extracted from the NHLS Corporate Data Warehouse and analysed using Microsoft Excel and Stata-12. Results. A substantial increase in the number of request forms with a CCMT programme status (28.1% v. 84.4%) was reported pre- and post-implementation. Post-implementation data (N=1 004) revealed ...

  3. Surface and interface electronic structure: Three year activity report

    International Nuclear Information System (INIS)

    Kevan, S.D.

    1992-01-01

    The 3-year activity report covers surface structure and phonon anomalies (surface reconstruction on W(001) and Mo(001), adsorbate lateral ordering, surface Fermi contours and phonon anomalies on Pt(111) and Pd(001)), adsorbate vibrational damping, charge transfer in momentum space: W(011)-K, surface states and resonances (relativistic effects ampersand computations, surface resonances)

  4. MFTF electron cyclotron resonance heating conceptual design study. Final report

    International Nuclear Information System (INIS)

    1979-01-01

    This report presents conceptual designs, discusses research and development requirements, and provides schedule requirements and rough order of magnitude cost estimates for the ECRH system. Requirements for the basic equipment needed to implement the ECRH power generators and distribute the power have been developed. Conceptual approaches to the development and fabrication of such a system have been generated

  5. A diagnostic for electron dynamics in tokamaks. Final report

    International Nuclear Information System (INIS)

    Skiff, F.; Boyd, D.

    1996-12-01

    The diagnostic was installed on TdeV and brought into operation. It was optimized to the extent that time and money permitted. A considerable quantity of data was accumulated and analyzed. Experiments ended in August 1995. The apparatus has been removed from TdeV and returned to the University of Maryland. Each of these activities is detailed in this report

  6. Pierce-Wiggler electron beam system for 250 GHz GYRO-BWO: Final report

    International Nuclear Information System (INIS)

    Pirkle, D.R.; Alford, C.W.; Anderson, M.H.; Garcia, R.F.; Legarra, J.R.; Nordquist, A.L.

    1989-01-01

    This final report summarizes the design and performance of the VUW-8028 Pierce-Wiggler electron beam systems, which can be used to power high frequency gyro-BWO's. The operator's manual for this gyro-BWO beamstick is included as appendix A. Researchers at Lawrence Livermore National Laboratory (LLNL) are developing a gyro-BWO with a center frequency of 250 GHz, 6% bandwidth, and 10 kV peak output power. The gyro-BWO will be used to drive a free electron laser amplifier at LLNL. The electron beam requirements of the gyro-BWO application are: Small beam size, .100 inch at 2500 gauss axial magnetic field; a large fraction of the electron energy in rotational velocity; ability to vary the electrons' axial velocity easily, for electronic tuning; and low velocity spread i.e. little variation in the axial velocities of the electrons in the interaction region. 1 ref., 13 figs

  7. INTRODUCTION Previous reports have documented a high ...

    African Journals Online (AJOL)

    Conclusion: The positive effect of education on oral hygiene practices is highlighted in this study. However there is still need for proper health enlightenment in this population with regards to use of the available oral health care facilities. Keywords: Oral hygiene, Pregnancy, Nigeria. Annals of Ibadan Postgraduate Medicine.

  8. Investigation of focusing of relativistic electron and positron bunches moving in cold plasma. Final report

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Elbakian, S.S.; Khachatryan, A.G.; Sekhpossian, E.V.

    1995-03-01

    This document is the final report on a project to study focusing effects of relativistic beams of electrons and positrons interacting with a cold plasma. The authors consider three different models for the overdense cold plasma - electron bunch interaction. They look at coulomb effects, wakefield effects, bunch parameters, and the effects of trains of pulses on focusing properties

  9. Femoral Component Revision with Use of Impaction Bone-Grafting and a Cemented Polished Stem: A Concise Follow-up, at Fifteen to Twenty Years, of a Previous Report*

    NARCIS (Netherlands)

    Te Stroet, M.A.; Gardeniers, J.W.M.; Verdonschot, N.J.; Rijnen, W.H.C.; Slooff, T.J.J.H.; Schreurs, B.W.

    2012-01-01

    We previously reported our results for thirty-three consecutive femoral component revisions with impaction bone-grafting, performed with the X-change femoral revision system and a cemented polished Exeter stem, at a minimum of eight years of follow-up. The present updated study shows the results

  10. Measuring penetration depth of electron beam welds. Final report

    International Nuclear Information System (INIS)

    Hill, J.W.; Collins, M.C.; Mentesana, C.P.; Watterson, C.E.

    1975-07-01

    The feasibility of evaluating electron beam welds using state-of-the-art techniques in the fields of holographic interferometry, micro-resistance measurements, and heat transfer was studied. The holographic study was aimed at evaluating weld defects by monitoring variations in weld strength under mechanical stress. The study, along with successful work at another facility, proved the feasibility of this approach for evaluating welds, but it did not assign any limitations to the technique. The micro-resistance study was aimed at evaluating weld defects by measuring the electrical resistance across the weld junction as a function of distance along the circumference. Experimentation showed this method, although sensitive, is limited by the same factors affecting other conventional nondestructive tests. Nevertheless, it was successful at distinguishing between various depths of penetration. It was also shown to be a sensitive thickness gage for thin-walled parts. The infrared study was aimed at evaluating weld defects by monitoring heat transfer through the weld under transient thermal conditions. Experimentation showed that this theoretically sound technique is not workable with the infrared equipment currently available at Bendix Kansas City. (U.S.)

  11. A diagnostic for electron dynamics in tokamaks. Final report

    International Nuclear Information System (INIS)

    Skiff, F.; Boyd, D.

    1997-12-01

    The diagnostic was installed on TdeV and brought into operation. It was optimized to the extent that time and money permitted. A considerable quantity of data was accumulated and analyzed. Experiments ended in August 1995. The apparatus has been removed from TdeV and returned to the University of Maryland. Each of these activities is detailed here. The diagnostic worked very well. Although the distribution functions behaved in ways that were not anticipated and the refractive losses were sometimes higher than projected, the authors were able to adapt to the unexpected. In the authors' estimation, all of the effects listed above are significant, and warrant further study. The diagnostic is ready for use as a tool to study the physics of current drive and current profile modification. A mechanism for steering the launched beams is desirable to cope with the strong variations in refraction which are seen. Phased array launchers seem attractive for this purpose. Tuning of the length of the waveguide run is important to avoid troublesome reflections (return losses). It may be best to build in this capability in a future system. The perpendicular dynamics of the current driven electrons are invisible to us with the present form of the diagnostic. Simultaneous measurements at fundamental and harmonic frequencies would make perpendicular distribution function measurements possible

  12. Service for maintenance of electronic equipment of the RA reactor, Report for 1977 - Annex IV

    International Nuclear Information System (INIS)

    Milosevic, M.

    1977-01-01

    This report describes the tasks and organizational structure of the Service for maintenance of electronic equipment of the RA reactor. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment related to the experimental devices [sr

  13. Electronic refrigerant leak detector. Quarterly technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Talamas, E. Jr.

    1998-10-15

    The project comprises three main tasks. They are (1) Develop, design, and fabricate sensors, (2) Develop, design, and fabricate test instruments, (3) Testing and data analysis. The milestone includes 17 sub-tasks for the 52-weeks project period, starting on May 1, 1998 and ending on April 30, 1999. As stated in the Application for Federal Assistance, Micronic intended to relocate to a new office by June of 1998. This decision was delayed, since the first partial payment was transferred on August 12, 1998. Micronic plans to relocate this November. A second Provisional Application for a US patent has been filed. Progress made during this period is reported.

  14. Second Line of Defense: Electronic Maintenance Reports, Local Maintenance Provider User Guide, Rev. 3

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, Richard J.

    2012-09-01

    The Electronic Maintenance Report forms allow Local Maintenance Providers (LMP) and other program staff to enter maintenance information into a simple and secure system. This document describes the features and information required to complete the Maintenance Report forms. It is expected that all Corrective Maintenance Reports from LMPs will be submitted electronically into the SLD Portal. As an exception (e.g., when access to the SLD Portal is unavailable), Maintenance Reports can be submitted via a secure Adobe PDF form available through the Sustainability Manager assigned to each country.

  15. Learning English through Automotive Electronics (Project LETAE), Final Evaluation Report, 1992-93. OREA Report.

    Science.gov (United States)

    New York City Board of Education, Brooklyn, NY. Office of Research, Evaluation, and Assessment.

    Learning Through Automotive Electronics (Project LETAE) was a federally funded program serving 77 limited-English-proficient (LEP) students and 5 English-proficient students in an automotive computer electronics course in 1992-93, its third year of operation. The program provided instruction in English-as-a-Second-Language (ESL), native language…

  16. 77 FR 47303 - Atlantic Highly Migratory Species; Electronic Dealer Reporting Requirements

    Science.gov (United States)

    2012-08-08

    ... the burden-hour estimates or other aspects of the collection-of-information requirements contained in... proposed rule also included flexible reporting regimes, which would allow NMFS to collect more frequent.... NMFS began designing and building an electronic reporting system when NMFS began working on the...

  17. How Does Nursing Staff Perceive the Use of Electronic Handover Reports? A Questionnaire-Based Study

    Directory of Open Access Journals (Sweden)

    Torbjørg Meum

    2011-01-01

    Full Text Available Following the implementation of electronic nursing records in a psychogeriatric ward, we examined nursing staff's attitudes and perceptions to the implementation of an electronic handover routine. A web-based anonymous and secure questionnaire was distributed by e-mail to all nursing staff at a psychogeriatric ward at a university hospital. Most respondents were satisfied with the electronic handover, and they believed they managed to keep informed by the new routine. The simultaneous introduction of a morning meeting, to ensure a forum for oral professional discussion, was a success. A minority of staff did not fully trust the information conveyed in the electronic handover, and a significant proportion expressed a need for guidance in using the system. Staff that had a high level of trust in written reports believed these saved time, had little trouble finding time and a place to read the reports, and were more positive to the new handover routine.

  18. Research on cw electron accelerators using room-temperature rf structures: Annual report

    International Nuclear Information System (INIS)

    1986-01-01

    This joint NBS-Los Alamos project of ''Research on CW Electron Accelerators Using Room-Temperature RF Structures'' began seven years ago with the goal of developing a technology base for cw electron accelerators. In this report we describe our progress during FY 1986 and present our plans for completion of the project. First, however, it is appropriate to review the past contributions of the project, describe its status, and indicate its future benefits

  19. Theory of photon and electron induced reactions: Progress report, July 1, 1986-June 30, 1987

    International Nuclear Information System (INIS)

    Onley, D.S.; Wright, L.E.

    1988-07-01

    During the third year of our three-year contract from the Department of Energy, we have made considerable progress or have completed our studies on the following aspects of the general investigation of electron and photon induced reactions; photo- and electro-production of mesons; the radiation tail accompanying elastic electron scattering and pair production; studies involving relativistic shell model; and electrofission coincidence angular distributions. We will report on each of these developments in this paper

  20. Theory of photon and electron induced reactions: Progress report, July 1, 1988--June 30, 1989

    International Nuclear Information System (INIS)

    Onley, D.S.; Wright, L.E.

    1989-03-01

    During the first twenty months of our new grant from the Department of Energy we have made considerable progress or have completed our studies on the following aspects of the general investigation of electron and photon induced reactions: photo- and electro-production of mesons; the radiation tail accompanying elastic electron scattering and pair production; and studies involving the relativistic shell model. We will report on each of these developments in the following sections

  1. Progress in increasing electronic reporting of laboratory results to public health agencies--United States, 2013.

    Science.gov (United States)

    2013-09-27

    Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.

  2. Status report of the Darmstadt polarized electron source at the S-DALINAC

    Energy Technology Data Exchange (ETDEWEB)

    Poltoratska, Yuliya; Barday, Roman; Bonnes, Uwe; Brunken, Marco; Eichhorn, Ralf; Eckardt, Christian; Enders, Joachim; Ingenhaag, Christoph; Goeoek, Alf; Platz, Markus; Roth, Markus; Wagner, Markus [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Mueller, Wolfgang F.O.; Weiland, Thomas [Institut fuer Theorie Elektromagnetischer Felder, Technische Universitaet, Darmstadt (Germany)

    2009-07-01

    The injection section of the superconducting Darmstadt electron linear accelerator S-DALINAC will soon be extended with a source of polarized electrons SPIN. The set-up consists of a 100 keV GaAs polarized gun and associated beamline including a Chopper-Prebuncher system to affect the time structure of the emitted beam, a laser system to produce polarized light with the required wavelength and an assembly for polarisation manipulation and measurement. We report on the status of the entire construction and review recent results on operation parameters. An outlook on the upcoming installation of the polarized electron source at the S-DALINAC is given.

  3. High-Temperature Air-Cooled Power Electronics Thermal Design: Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Waye, Scot [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    Power electronics that use high-temperature devices pose a challenge for thermal management. With the devices running at higher temperatures and having a smaller footprint, the heat fluxes increase from previous power electronic designs. This project overview presents an approach to examine and design thermal management strategies through cooling technologies to keep devices within temperature limits, dissipate the heat generated by the devices and protect electrical interconnects and other components for inverter, converter, and charger applications. This analysis, validation, and demonstration intends to take a multi-scale approach over the device, module, and system levels to reduce size, weight, and cost.

  4. Dynamic Processes in Biology, Chemistry, and Materials Science: Opportunities for UltraFast Transmission Electron Microscopy - Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Kabius, Bernd C.; Browning, Nigel D.; Thevuthasan, Suntharampillai; Diehl, Barbara L.; Stach, Eric A.

    2012-07-25

    This report summarizes a 2011 workshop that addressed the potential role of rapid, time-resolved electron microscopy measurements in accelerating the solution of important scientific and technical problems. A series of U.S. Department of Energy (DOE) and National Academy of Science workshops have highlighted the critical role advanced research tools play in addressing scientific challenges relevant to biology, sustainable energy, and technologies that will fuel economic development without degrading our environment. Among the specific capability needs for advancing science and technology are tools that extract more detailed information in realistic environments (in situ or operando) at extreme conditions (pressure and temperature) and as a function of time (dynamic and time-dependent). One of the DOE workshops, Future Science Needs and Opportunities for Electron Scattering: Next Generation Instrumentation and Beyond, specifically addressed the importance of electron-based characterization methods for a wide range of energy-relevant Grand Scientific Challenges. Boosted by the electron optical advancement in the last decade, a diversity of in situ capabilities already is available in many laboratories. The obvious remaining major capability gap in electron microscopy is in the ability to make these direct in situ observations over a broad spectrum of fast (µs) to ultrafast (picosecond [ps] and faster) temporal regimes. In an effort to address current capability gaps, EMSL, the Environmental Molecular Sciences Laboratory, organized an Ultrafast Electron Microscopy Workshop, held June 14-15, 2011, with the primary goal to identify the scientific needs that could be met by creating a facility capable of a strongly improved time resolution with integrated in situ capabilities. The workshop brought together more than 40 leading scientists involved in applying and/or advancing electron microscopy to address important scientific problems of relevance to DOE’s research

  5. Proposed Physics Experiments for Laser-Driven Electron Linear Acceleration in a Dielectric Loaded Vacuum, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Byer, Robert L. [Stanford Univ., CA (United States). Dept. of Applied Physics. Edward L. Ginzton Lab.

    2016-07-08

    This final report summarizes the last three years of research on the development of advanced linear electron accelerators that utilize dielectric wave-guide vacuum channels pumped by high energy laser fields to accelerate beams of electrons.

  6. An infrared free-electron laser for the Chemical Dynamics Research Laboratory. Design report

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. [comp.

    1992-04-01

    This document describes a free-electron laser (FEL) proposed as part of the Chemical Dynamics Research Laboratory (CDRL), a user facility that also incorporates several advanced lasers of conventional design and two beamlines for the ALS. The FEL itself addresses the needs of the chemical sciences community for a high-brightness, tunable source covering a broad region of the infrared spectrum -- from 3 to 50 {mu}m. All of these sources, together with a variety of sophisticated experimental stations, will be housed in a new building to be located adjacent to the ALS. The radiation sources can be synchronized to permit powerful two-color, pump-probe experiments that will further our fundamental understanding of chemical dynamics at the molecular level, especially those aspects relevant to practical issues in combustion chemistry. The technical approach adopted in this design makes use of superconducting radiofrequency (SCRF) accelerating structures. The primary motivation for adopting this approach was to meet the user requirement for wavelength stability equal to one part in 10{sup 4}. Previous studies concluded that a wavelength stability of only one part in 10{sup 3} could be achieved with currently available room-temperature technology. In addition, the superconducting design operates in a continuous-wave (cw) mode and hence offers considerably higher average optical output power. It also allows for various pulse-gating configurations that will permit simultaneous multiuser operations. A summary of the comparative performance attainable with room-temperature and superconducting designs is given. The FEL described in this report provides a continuous train of 30-ps micropulses, with 100{mu}J of optical energy per micropulse, at a repetition rate of 6.1 MHz. The device can also deliver pulses at a cw repetition rate of 12.2 MHz, with a peak power of 50 {mu}J per micropulse. 70 ref.

  7. Improving linear accelerator service response with a real- time electronic event reporting system.

    Science.gov (United States)

    Hoisak, Jeremy D P; Pawlicki, Todd; Kim, Gwe-Ya; Fletcher, Richard; Moore, Kevin L

    2014-09-08

    To track linear accelerator performance issues, an online event recording system was developed in-house for use by therapists and physicists to log the details of technical problems arising on our institution's four linear accelerators. In use since October 2010, the system was designed so that all clinical physicists would receive email notification when an event was logged. Starting in October 2012, we initiated a pilot project in collaboration with our linear accelerator vendor to explore a new model of service and support, in which event notifications were also sent electronically directly to dedicated engineers at the vendor's technical help desk, who then initiated a response to technical issues. Previously, technical issues were reported by telephone to the vendor's call center, which then disseminated information and coordinated a response with the Technical Support help desk and local service engineers. The purpose of this work was to investigate the improvements to clinical operations resulting from this new service model. The new and old service models were quantitatively compared by reviewing event logs and the oncology information system database in the nine months prior to and after initiation of the project. Here, we focus on events that resulted in an inoperative linear accelerator ("down" machine). Machine downtime, vendor response time, treatment cancellations, and event resolution were evaluated and compared over two equivalent time periods. In 389 clinical days, there were 119 machine-down events: 59 events before and 60 after introduction of the new model. In the new model, median time to service response decreased from 45 to 8 min, service engineer dispatch time decreased 44%, downtime per event decreased from 45 to 20 min, and treatment cancellations decreased 68%. The decreased vendor response time and reduced number of on-site visits by a service engineer resulted in decreased downtime and decreased patient treatment cancellations.

  8. Study of electrons photoemitted from field emission tips. Progress report, July 1, 1979-March 1, 1980

    International Nuclear Information System (INIS)

    Reifenberger, R.

    1980-02-01

    Photo-induced field emission is a technique which studies electrons that have been photoemitted from a field emission tip. This new experimental method promises to combine the proven utility of both field emission and photoemission for investigating the electronic states near a metal surface. The primary objective of the research being performed is to investigate photo-induced field emitted electrons using a tuneable cw dye laser. To fully exploit this continuously tuneable photon source, a differential energy analyzer is being constructed to allow energy resolved measurements of the photo-field emitted electrons. This report describes the progress made in implementing experiments on photo-induced field emission from July 1979 to March 1980

  9. Status report of the S-DALINAC polarized electron injector SPIN at Darmstadt

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, Christian; Bahlo, Thore; Bangert, Phillip; Barday, Roman; Bonnes, Uwe; Brunken, Marco; Eichhorn, Ralf; Enders, Joachim; Platz, Markus; Poltoratska, Yuliya; Roth, Markus; Schneider, Fabian; Wagner, Markus; Weber, Antje; Zwicker, Benjamin [Institut fuer Kernphysik, Technische Universitaet Darmstadt (Germany); Ackermann, Wolfgang; Mueller, Wolfgang F.O.; Weiland, Thomas [Institut fuer Theorie Elektromagnetischer Felder, Technische Universitaet Darmstadt (Germany)

    2010-07-01

    At the superconducting 130 MeV Darmstadt electron linac S-DALINAC a source of polarized electrons is being installed. Polarized electrons are produced by photoemission from a negative electron affinity strained superlattice GaAs cathode and preaccelerated to 100 keV. With a Wien filter and Mott polarimeter in the beam line the polarization is manipulated and measured. For beam diagnostics wire scanners, fluorescent screens and a coaxial Faraday cup are included. To measure the beam polarization at higher energies, a 5-10 MeV Mott polarimeter and a 50-130 MeV Moeller polarimeter as well as a Compton transmission polarimeter will be installed. We report on the status of the implementation and show plans for future development and experiments.

  10. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    Science.gov (United States)

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  11. E-Division semiannual report. Progress report, June 1--December 31, 1977. [Electronics and Instrumentation Division, LASL

    Energy Technology Data Exchange (ETDEWEB)

    Kelley, P.A. (comp.)

    1978-03-01

    The status of the programs and projects of the Electronics Division is reported for the period of June through December 1977. The presentation is divided into three sections: Research, Engineering Support, and Technical Services. Each of these sections presents the activities and accomplishments of the corresponding branch within the Division. The primary goal of the Research and Development branch is to advance technology for future applications. The primary goal of the Engineering Support branch is to apply advanced technology to laboratory and material problems. The primary goal of the Technical Services branch is to provide a technical base and support for Laboratory programs. These goals are reflected in this report. Among the subject areas included are the following: radiation detectors, temperature monitoring, electromagnetic probing, Josephson junction switching devices, fiber optics, high-temperature electronics, HVAC systems, microprocessors, fuel cell-powered vehicles, laser fusion.

  12. Elastic neutrino-electron scattering: a progress report on Exp734 at Brookhaven

    International Nuclear Information System (INIS)

    Abe, K.; Ahrens, L.A.; Amako, K.

    1983-01-01

    I will report preliminary results on elastic neutrino-electron scattering from data taken with the 200 ton segmented liquid scintillator - proportional drift-tube neutrino detector at Brookhaven. Features of the detector (such as the active target and long radiation length) permit a uniquely clean signal. Prospects of results from the completed analysis and further data taking are discussed

  13. 75 FR 65439 - Defense Federal Acquisition Regulation Supplement; Electronic Subcontracting Reporting System

    Science.gov (United States)

    2010-10-25

    ... Accounting Service or Missile Defense Agency. (2) For DoD, the authority to acknowledge receipt or reject... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Parts 219 and 252 [DFARS Case 2009-D002] Defense Federal Acquisition Regulation Supplement; Electronic Subcontracting Reporting...

  14. Second Line of Defense Help Desk: Electronic Maintenance Reports - Local Maintenance Provider User Guide Rev. 1

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, Richard J.

    2011-12-14

    The Electronic Maintenance Report forms present a uniform dataset for analysis of Sustainability metrics. These forms collect readily minable data while allowing the attachment of site-specific checklists or other supporting files for review by the Sustainability Manager and Program Management.

  15. 76 FR 36919 - Proof of Concept Demonstration for Electronic Reporting of Clean Water Act Compliance Monitoring...

    Science.gov (United States)

    2011-06-23

    ... reporting services to the regulated community for the NPDES program (e.g., NPDES permitted facilities). This open platform model would likely be similar to the Internal Revenue Service (IRS) model for electronic... Federal and state levels, to strengthen that performance, and to transform EPA's water quality and...

  16. [A high resolution projection electron spectrometers]: Final report 1978-1987

    International Nuclear Information System (INIS)

    1988-01-01

    The main emphasis of the work has been to study inner shell ionization processes. The signatures have been K x-rays or K Auger transitions. We have worked with semiconductor or Bragg x-ray spectrometers. Toward the end of the contract we concentrated on projectile electron spectroscopy. These topics and other atomic physics projects are described briefly in this progress report

  17. Demonstration of a Prototype Hydrogen Sensor and Electronics Package - Progress Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Amanda S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brosha, Eric [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-14

    This is the second progress report on the demonstration of a prototype hydrogen sensor and electronics package. It goes into detail about the five tasks, four of which are already completed as of August 2016, with the final to be completed by January 26, 2017. Then the budget is detailed along with the planned work for May 27, 2016 to July 27, 2016.

  18. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    International Nuclear Information System (INIS)

    1987-10-01

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH) has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided

  19. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  20. Audit Report on "Protection of the Department of Energy's Unclassified Sensitive Electronic Information"

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-08-01

    The Department of Energy and its contractors store and process massive quantities of sensitive information to accomplish national security, energy, science, and environmental missions. Sensitive unclassified data, such as personally identifiable information (PII), official use only, and unclassified controlled nuclear information require special handling and protection to prevent misuse of the information for inappropriate purposes. Industry experts have reported that more than 203 million personal privacy records have been lost or stolen over the past three years, including information maintained by corporations, educational institutions, and Federal agencies. The loss of personal and other sensitive information can result in substantial financial harm, embarrassment, and inconvenience to individuals and organizations. Therefore, strong protective measures, including data encryption, help protect against the unauthorized disclosure of sensitive information. Prior reports involving the loss of sensitive information have highlighted weaknesses in the Department's ability to protect sensitive data. Our report on Security Over Personally Identifiable Information (DOE/IG-0771, July 2007) disclosed that the Department had not fully implemented all measures recommended by the Office of Management and Budget (OMB) and required by the National Institute of Standards and Technology (NIST) to protect PII, including failures to identify and encrypt PII maintained on information systems. Similarly, the Government Accountability Office recently reported that the Department had not yet installed encryption technology to protect sensitive data on the vast majority of laptop computers and handheld devices. Because of the potential for harm, we initiated this audit to determine whether the Department and its contractors adequately safeguarded sensitive electronic information. The Department had taken a number of steps to improve protection of PII. Our review, however

  1. HIV risk perception and testing behaviours among men having sex with men (MSM) reporting potential transmission risks in the previous 12 months from a large online sample of MSM living in Germany.

    Science.gov (United States)

    Marcus, Ulrich; Gassowski, Martyna; Drewes, Jochen

    2016-10-22

    HIV testing and serostatus awareness are essential to implement biomedical strategies (treatment as prevention; oral chemoprophylaxis), and for effective serostatus-based behaviours (HIV serosorting; strategic positioning). The analysis focuses on the associations between reported sexual risks, the perceived risk for HIV infection, and HIV testing behaviour in order to identify the most relevant barriers for HIV test uptake among MSM living in Germany. MSM were recruited to a nationwide anonymous online-survey in 2013 on MSM social networking/dating sites. Questions covered testing behaviours, reasons for testing decisions, and HIV risk perception (5-point scale). Additional questions addressed arguments in favour of home/ home collection testing (HT). Using descriptive statistics and logistic regression we compared men reporting recent HIV testing (RT; previous 12 month) with men never tested (NT) in a subsample not previously diagnosed with HIV and reporting ≥2 episodes of condomless anal intercourse (CLAI) with a non-steady partner of unknown HIV serostatus in the previous 12 months. The subsample consisted of 775 RT (13 % of RT) and 396 NT (7 % of NT). The number of CLAI episodes in the last 12 months with non-steady partners of unknown HIV status did not differ significantly between the groups, but RT reported significantly higher numbers of partners (>5 AI partners: 65 vs. 44 %). While perceived risks regarding last AI were comparable between the groups, 49vs. 30 % NT were risks (67 %) and routine testing (49 %) were the most common testing reasons for RT, while the strong belief not to be infected (59 %) and various worries (41 %) and fears of testing positive (35 %) were predominant reasons of NT. Greater anonymity (aOR 3.2; 2.4-4.4), less embarrassment, (aOR 2.8; 1.9-4.1), and avoiding discussions on sexual behaviour (aOR 1.6; 1.1-2.2) were emphasized in favour of HT by NT. Perceived partner knowledge and reasons reflecting perceived gay- and

  2. Successful adalimumab treatment of a psoriasis vulgaris patient with hemodialysis for renal failure: A case report and a review of the previous reports on biologic treatments for psoriasis patients with hemodialysis for renal failure.

    Science.gov (United States)

    Kusakari, Yoshiyuki; Yamasaki, Kenshi; Takahashi, Toshiya; Tsuchiyama, Kenichiro; Shimada-Omori, Ryoko; Nasu-Tamabuchi, Mei; Aiba, Setsuya

    2015-07-01

    The efficacy and safety of biologic treatments have been established in patients with moderate to severe psoriasis, but there are few reports on biologic therapy for patients with psoriasis complicated by end-stage renal failure on hemodialysis (HD). In this report, we demonstrated the efficacy and safety of adalimumab for patients with severe psoriasis on HD. A 46-year-old Japanese man with a 14-year history of psoriasis was referred to our clinic in September 2009. He had developed hypertension and renal failure during a 7-year history of cyclosporin treatment. With the infliximab treatment, he achieved 75% improvement of the Psoriasis Area and Severity Index (PASI) score within 3 months from the PASI of 42.3 before the treatment. However, his renal failure gradually deteriorated, and HD was initiated at 1 year after the introduction of infliximab. Because of hydration during the i.v. injection of infliximab, he developed pulmonary edema with every infliximab treatment after starting HD. We switched to ustekinumab treatment, but his psoriasis was not improved. Then, we switched to adalimumab and achieved a PASI-100 response within 2 months. The patient received adalimumab treatment for more than a year without any adverse effects. In addition to our case, five articles reported cases of psoriasis patients with renal failure on HD who were treated with biologics. The psoriatic lesions were improved by biologics in these cases, and no severe adverse effects on the renal function were reported. Thus, biologics are a reasonable treatment option for patients with severe psoriasis with renal failure on HD. © 2015 Japanese Dermatological Association.

  3. Barriers to the success of an electronic pharmacovigilance reporting system in Kenya: an evaluation three years post implementation.

    Science.gov (United States)

    Agoro, Oscar O; Kibira, Sarah W; Freeman, Jenny V; Fraser, Hamish S F

    2018-06-01

    Electronic pharmacovigilance reporting systems are being implemented in many developing countries in an effort to improve reporting rates. This study sought to establish the factors that acted as barriers to the success of an electronic pharmacovigilance reporting system in Kenya 3 years after its implementation. Factors that could act as barriers to using electronic reporting systems were identified in a review of literature and then used to develop a survey questionnaire that was administered to pharmacists working in government hospitals in 6 counties in Kenya. The survey was completed by 103 out of the 115 targeted pharmacists (89.5%) and included free-text comments. The key factors identified as barriers were: unavailable, unreliable, or expensive Internet access; challenges associated with a hybrid system of paper and electronic reporting tools; and system usability issues. Coordination challenges at the national pharmacovigilance center and changes in the structure of health management in the country also had an impact on the success of the electronic reporting system. Different personal, organizational, infrastructural, and reporting system factors affect the success of electronic reporting systems in different ways, depending on the context. Context-specific formative evaluations are useful in establishing the performance of electronic reporting systems to identify problems and ensure that they achieve the desired objectives. While several factors hindered the optimal use of the electronic pharmacovigilance reporting system in Kenya, all were considered modifiable. Effort should be directed toward tackling the identified issues in order to facilitate use and improve pharmacovigilance reporting rates.

  4. Photoinduced Electron Transfer in Ordered Macromolecular Assemblies. Final report for May 1, 1988 - June 30, 2002

    Energy Technology Data Exchange (ETDEWEB)

    Jones, G.

    2005-02-11

    The final report describes studies over a 13 year period having to do with photoinduced electron transfer for active chromophores and redox agents, including assembly of the components in water soluble polymers or polypeptides. The findings include observation of long range charge separation and electron transport using laser phototransient spectroscopy. The systems targeted in these studies include peptide assemblies for which helical conformations and aggregation are documented. Oligomeric peptides modified with non-native redox active groups were also selected for investigation. Highly charged polymers or peptides were investigated as host agents that resemble proteins. The overall goal of these investigations focused on the design and characterization of systems capable of artificial photosynthesis.

  5. Case Study: Converting Paper-based Case Report Forms to an Electronic Format (e-CRF) with ACASI Self-Report Integration.

    Science.gov (United States)

    Mierzwa, Stan; Souidi, Samir; Akello, Carolyne; Etima, Juliane; Ssebagala, Richard; Nolan, Monica; Kabwigu, Samuel; Nakablito, Clemensia

    2017-01-01

    This paper will discuss the integration of electronic Case Report Forms (e-CRFs) into an already existing Android-based Audio Computer-Assisted Self-Interview (ACASI) software solution that was developed for a public health project in Kampala, Uganda, the technical outcome results, and lessons learned that may be useful to other projects requiring or considering such a technology solution. The developed product can function without a connection to the Internet and allows for synchronizing collected data once connectivity is possible. Previously, only paper-based CRFs were utilized at the Uganda project site. A subset or select group of CRFs were targeted for integration with ACASI in order to test feasibility and success. Survey volume, error rate, and acceptance of the system, as well as the operational and technical design of the solution, will be discussed.

  6. Final Report for 'ParSEC-Parallel Simulation of Electron Cooling''

    International Nuclear Information System (INIS)

    David L Bruhwiler

    2005-01-01

    The Department of Energy has plans, during the next two or three years, to design an electron cooling section for the collider ring at RHIC (Relativistic Heavy Ion Collider) [1]. Located at Brookhaven National Laboratory (BNL), RHIC is the premier nuclear physics facility. The new cooling section would be part of a proposed luminosity upgrade [2] for RHIC. This electron cooling section will be different from previous electron cooling facilities in three fundamental ways. First, the electron energy will be 50 MeV, as opposed to 100's of keV (or 4 MeV for the electron cooling system now operating at Fermilab [3]). Second, both the electron beam and the ion beam will be bunched, rather than being essentially continuous. Third, the cooling will take place in a collider rather than in a storage ring. Analytical work, in combination with the use and further development of the semi-analytical codes BETACOOL [4,5] and SimCool [6,7] are being pursued at BNL [8] and at other laboratories around the world. However, there is a growing consensus in the field that high-fidelity 3-D particle simulations are required to fully understand the critical cooling physics issues in this new regime. Simulations of the friction coefficient, using the VORPAL code [9], for single gold ions passing once through the interaction region, have been compared with theoretical calculations [10,11], and the results have been presented in conference proceedings papers [8,12,13,14] and presentations [15,16,17]. Charged particles are advanced using a fourth-order Hermite predictor corrector algorithm [18]. The fields in the beam frame are obtained from direct calculation of Coulomb's law, which is more efficient than multipole-type algorithms for less than ∼ 10 6 particles. Because the interaction time is so short, it is necessary to suppress the diffusive aspect of the ion dynamics through the careful use of positrons in the simulations, and to run 100's of simulations with the same physical

  7. Experiments on continuum electron capture in atomic hydrogen and collisional interaction of trapped ions. Progress report

    International Nuclear Information System (INIS)

    Sellin, I.A.; Elston, S.B.

    1981-01-01

    This section describes the background and scope of as well as progress made on experiments designed to test the present theory of charge exchange to continuum for the case of bare nuclei on atomic hydrogen. The charge transfer process is well known to be an essential ingredient of any attempt to understand the ionization of gaseous media traversed by highly-charged energetic ions. Surprisingly, a sometimes dominant contribution to such ionization remained undiscovered until the past decade. This process, known as charge transfer to the continuum, involves the ionization of electrons from the target species into unbound states closely matched in exit direction and speed to the charged particles which generate them. Subsequent measurements of the resultant forward electron production, performed by University of Tennessee searchers at Oak Ridge and Brookhaven National Laboratories, were unique in employing more highly charged projectiles than previously

  8. HINS R and D Collaboration on Electron Cloud Effects: Midyear Report

    International Nuclear Information System (INIS)

    Furman, M.A.; Sonnad, K.; Vay, J.-L.

    2006-01-01

    We present a report on ongoing activities on electron-cloud R and D for the MI upgrade. These results update and extend those presented in Refs. 1, 2. In this report we have significantly expanded the parameter range explored in bunch intensity Nb, RMS bunch length σ z and peak secondary emission yield (SEY) (delta) max , but we have constrained our simulations to a field-free region. We describe the threshold behaviors in all of the above three parameters. For (delta) max (ge) 1.5 we find that, even for N b = 1 x 10 11 , the electron cloud density, when averaged over the entire chamber, exceeds the beam neutralization level, but remains significantly below the local neutralization level (ie., when the electron density is computed in the neighborhood of the beam). This 'excess' of electrons is accounted for by narrow regions of high concentration of electrons very close to the chamber surface, especially at the top and bottom of the chamber, akin to virtual cathodes. These virtual cathodes are kept in equilibrium, on average, by a competition between space-charge forces (including their images) and secondary emission, a mechanism that shares some features with the space-charge saturation of the current in a diode at high fields. For N b = 3 x 10 11 the electron cloud build-up growth rate and saturation density have a strong dependence on σ z as σ z decreases below ∼ 0.4 m, when the average electron-wall impact energy roughly reaches the energy E max where (delta) peaks. We also present improved results on emittance growth simulations of the beam obtained with the code WARP/POSINST in quasi-static mode, in which the beam-(electron cloud) interaction is lumped into N s 'stations' around the ring, where N s = 1, 2,..., 9. The emittance shows a rapid growth of ∼ 20% during the first ∼ 100 turns, followed by a much slower growth rate of ∼ 0.03%/turn. Concerning the electron cloud detection technique using microwave transmission, we present an improved

  9. Risk factors for radiotherapy incidents and impact of an online electronic reporting system

    International Nuclear Information System (INIS)

    Chang, David W.; Cheetham, Lynn; Marvelde, Luc te; Bressel, Mathias; Kron, Tomas; Gill, Suki; Tai, Keen Hun; Ball, David; Rose, William; Silva, Linas; Foroudi, Farshad

    2014-01-01

    Background and purpose: To ascertain the rate, type, significance, trends and the potential risk factors associated with radiotherapy incidents in a large academic department. Materials and methods: Data for all radiotherapy activities from July 2001 to January 2011 were reviewed from radiotherapy incident reporting forms. Patient and treatment data were obtained from the radiotherapy record and verification database (MOSAIQ) and the patient database (HOSPRO). Logistic regression analyses were performed to determine variables associated with radiotherapy incidents. Results: In that time, 65,376 courses of radiotherapy were delivered with a reported incident rate of 2.64 per 100 courses. The rate of incidents per course increased (1.96 per 100 courses to 3.52 per 100 courses, p < 0.001) whereas the proportion of reported incidents resulting in >5% deviation in dose (10.50 to 2.75%, p < 0.001) had decreased after the introduction of an online electronic reporting system. The following variables were associated with an increased rate of incidents: afternoon treatment time, paediatric patients, males, inpatients, palliative plans, head-and-neck, skin, sarcoma and haematological malignancies. In general, complex plans were associated with higher incidence rates. Conclusion: Radiotherapy incidents were infrequent and most did not result in significant dose deviation. A number of risk factors were identified and these could be used to highlight high-risk cases in the future. Introduction of an online electronic reporting system resulted in a significant increase in the number of incidents being reported

  10. HIV risk perception and testing behaviours among men having sex with men (MSM reporting potential transmission risks in the previous 12 months from a large online sample of MSM living in Germany

    Directory of Open Access Journals (Sweden)

    Ulrich Marcus

    2016-10-01

    Full Text Available Abstract Background HIV testing and serostatus awareness are essential to implement biomedical strategies (treatment as prevention; oral chemoprophylaxis, and for effective serostatus-based behaviours (HIV serosorting; strategic positioning. The analysis focuses on the associations between reported sexual risks, the perceived risk for HIV infection, and HIV testing behaviour in order to identify the most relevant barriers for HIV test uptake among MSM living in Germany. Methods MSM were recruited to a nationwide anonymous online-survey in 2013 on MSM social networking/dating sites. Questions covered testing behaviours, reasons for testing decisions, and HIV risk perception (5-point scale. Additional questions addressed arguments in favour of home/ home collection testing (HT. Using descriptive statistics and logistic regression we compared men reporting recent HIV testing (RT; previous 12 month with men never tested (NT in a subsample not previously diagnosed with HIV and reporting ≥2 episodes of condomless anal intercourse (CLAI with a non-steady partner of unknown HIV serostatus in the previous 12 months. Results The subsample consisted of 775 RT (13 % of RT and 396 NT (7 % of NT. The number of CLAI episodes in the last 12 months with non-steady partners of unknown HIV status did not differ significantly between the groups, but RT reported significantly higher numbers of partners (>5 AI partners: 65 vs. 44 %. While perceived risks regarding last AI were comparable between the groups, 49vs. 30 % NT were <30 years, lived more often in towns/villages <100,000 residents (60 vs. 39 %, were less out-particularly towards care providers-about being attracted to men (aOR 10.1; 6.9–14.8, more often identified as bisexual (aOR 3.5; 2.5–4.8, and reported lower testing intentions (aOR 0.08; 0.06–0.11. Perceived risks (67 % and routine testing (49 % were the most common testing reasons for RT, while the strong belief not to be infected

  11. Design report on a 10-in. multiwire proportional chamber (MWPC) and associated electronics

    International Nuclear Information System (INIS)

    MacArthur, D.W.

    1987-02-01

    We discuss the design and specifications of a 10-in. x 10-in. active area wire chamber. Several of these chambers will be combined with polyethylene converters to make a large volume detector intended for use as a high-energy detector displaying moderate energy resolution. We also discuss the amplifiers and discriminators that have been designed for these chambers. This report only concerns the wire chambers and electronics

  12. Excitation and ionization of ions by electron impact. Final report, September 1, 1969-March 31, 1980

    International Nuclear Information System (INIS)

    Feeney, R.K.; Hughes, D.W.; Hooper, J.W.

    1980-01-01

    This report presents a brief summary of the technical accomplishments of a research program active from September 1, 1969, through March 31, 1980. All of the work was related to the atomic collision process of importance in magnetic confinement fusion. A chronological tabulation of technical accomplishments, a list of publications, and a summary of progress in the measurement of electron impact ionization cross sections are given

  13. Bibliography of low energy electron and photon cross section data (through December 1974). Final report

    International Nuclear Information System (INIS)

    Kieffer, L.J.

    1976-03-01

    A bibliography of original reports of measurements or calculations of electron, positron and photon cross sections and their ions is presented. A detailed index to the bibliography allows retrieval of cross section data for specific processes and atomic or molecular species. A comprehensive author index is included. The bibliography covers the period 1921 through calendar year 1974, but some references late in 1974 may not have been found and included. No references were found prior to 1921

  14. Workshop report of problems relating to multi-electron excited ions in plasma

    International Nuclear Information System (INIS)

    Fujimoto, Takashi; Suzuki, Hiroshi; Takayanagi, Toshinobu; Koike, Fumihiro; Nakamura, Koji.

    1979-08-01

    A workshop was held to discuss the problems relating to multiple electron-excited ions in plasma. The first part of this report deals with the problems of satellite lines. The satellite lines from laser plasma and vacuum sparks are discussed. Review papers on satellite lines and bielectronic recombination are also presented. The second part of this report deals with the problems of autoionization. Theory, comment on the compound state, observation of autoionization and resonance scattering, excitation cross-section, inner shell ionization, excitation through autoionization, and the bielectronic recombination of helium-like ions are discussed. (Kato, T.)

  15. Electron microscope studies. Progress report, 1 July 1964--1 June 1992

    Energy Technology Data Exchange (ETDEWEB)

    Crewe, A.V.; Kapp, O.H.

    1992-07-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations.

  16. Assessing explicit error reporting in the narrative electronic medical record using keyword searching.

    Science.gov (United States)

    Cao, Hui; Stetson, Peter; Hripcsak, George

    2003-01-01

    Many types of medical errors occur in and outside of hospitals, some of which have very serious consequences and increase cost. Identifying errors is a critical step for managing and preventing them. In this study, we assessed the explicit reporting of medical errors in the electronic record. We used five search terms "mistake," "error," "incorrect," "inadvertent," and "iatrogenic" to survey several sets of narrative reports including discharge summaries, sign-out notes, and outpatient notes from 1991 to 2000. We manually reviewed all the positive cases and identified them based on the reporting of physicians. We identified 222 explicitly reported medical errors. The positive predictive value varied with different keywords. In general, the positive predictive value for each keyword was low, ranging from 3.4 to 24.4%. Therapeutic-related errors were the most common reported errors and these reported therapeutic-related errors were mainly medication errors. Keyword searches combined with manual review indicated some medical errors that were reported in medical records. It had a low sensitivity and a moderate positive predictive value, which varied by search term. Physicians were most likely to record errors in the Hospital Course and History of Present Illness sections of discharge summaries. The reported errors in medical records covered a broad range and were related to several types of care providers as well as non-health care professionals.

  17. Final Report Theoretical Studies of Surface Reactions on Metals and Electronic Materials

    Energy Technology Data Exchange (ETDEWEB)

    Jerry L. Whitten

    2012-04-23

    This proposal describes the proposed renewal of a theoretical research program on the structure and reactivity of molecules adsorbed on transition metal surfaces. A new direction of the work extends investigations to interfaces between solid surfaces, adsorbates and aqueous solutions and includes fundamental work on photoinduced electron transport into chemisorbed species and into solution. The goal is to discover practical ways to reduce water to hydrogen and oxygen using radiation comparable to that available in the solar spectrum. The work relates to two broad subject areas: photocatalytic processes and production of hydrogen from water. The objective is to obtain high quality solutions of the electronic structure of adsorbate-metal-surface-solution systems so as to allow activation barriers to be calculated and reaction mechanisms to be determined. An ab initio embedding formalism provides a route to the required accuracy. New theoretical methods developed during the previous grant period will be implemented in order to solve the large systems involved in this work. Included is the formulation of a correlation operator that is used to treat localized electron distributions such as ionic or regionally localized distributions. The correlation operator which is expressed as a two-particle projector is used in conjunction with configuration interaction.

  18. REPORT ON THE PANEL SESSION: EMERGING ELECTRONICS ISSUES - HOW CAN WE MINIMIZE THE HEALTH AND ENVIRONMENTAL IMPACTS OF ELECTRONICS RECYCLING?

    Science.gov (United States)

    The production and use of electronic products is growing and the rapid pace at which the technology advances means that many electronic products become obsolete in a relatively short period of time. These factors are contributing to a growing challenge for waste management becaus...

  19. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee report on electronic brachytherapy.

    Science.gov (United States)

    Park, Catherine C; Yom, Sue S; Podgorsak, Matthew B; Harris, Eleanor; Price, Robert A; Bevan, Alison; Pouliot, Jean; Konski, Andre A; Wallner, Paul E

    2010-03-15

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site. Copyright 2010. Published by Elsevier Inc.

  20. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

    International Nuclear Information System (INIS)

    Park, Catherine C.; Yom, Sue S.; Podgorsak, Matthew B.; Harris, Eleanor; Price, Robert A.; Bevan, Alison; Pouliot, Jean; Konski, Andre A.; Wallner, Paul E.

    2010-01-01

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

  1. Validation of previously reported predictors for radiation-induced hypothyroidism in nasopharyngeal cancer patients treated with intensity-modulated radiation therapy, a post hoc analysis from a Phase III randomized trial.

    Science.gov (United States)

    Lertbutsayanukul, Chawalit; Kitpanit, Sarin; Prayongrat, Anussara; Kannarunimit, Danita; Netsawang, Buntipa; Chakkabat, Chakkapong

    2018-05-10

    This study aimed to validate previously reported dosimetric parameters, including thyroid volume, mean dose, and percentage thyroid volume, receiving at least 40, 45 and 50 Gy (V40, V45 and V50), absolute thyroid volume spared (VS) from 45, 50 and 60 Gy (VS45, VS50 and VS60), and clinical factors affecting the development of radiation-induced hypothyroidism (RHT). A post hoc analysis was performed in 178 euthyroid nasopharyngeal cancer (NPC) patients from a Phase III study comparing sequential versus simultaneous-integrated boost intensity-modulated radiation therapy. RHT was determined by increased thyroid-stimulating hormone (TSH) with or without reduced free thyroxin, regardless of symptoms. The median follow-up time was 42.5 months. The 1-, 2- and 3-year freedom from RHT rates were 78.4%, 56.4% and 43.4%, respectively. The median latency period was 21 months. The thyroid gland received a median mean dose of 53.5 Gy. Female gender, smaller thyroid volume, higher pretreatment TSH level (≥1.55 μU/ml) and VS60 treatment planning.

  2. [Electronic and structural properties of individual nanometer-size supported metallic clusters]. Final performance report

    Energy Technology Data Exchange (ETDEWEB)

    Reifenberger, R.

    1993-09-01

    This report summarizes the work performed under contract DOE-FCO2-84ER45162. During the past ten years, our study of electron emission from laser-illuminated field emission tips has taken on a broader scope by addressing problems of direct interest to those concerned with the unique physical and chemical properties of nanometer-size clusters. The work performed has demonstrated that much needed data can be obtained on individual nanometer-size clusters supported on a wide-variety of different substrates. The work was performed in collaboration with R.P. Andres in the School of Chemical Engineering at Purdue University. The Multiple Expansion Cluster Source developed by Andres and his students was essential for producing the nanometer-size clusters studied. The following report features a discussion of these results. This report provides a motivation for studying the properties of nanometer-size clusters and summarizes the results obtained.

  3. Electronic Self-report Assessment--Cancer (ESRA-C): Working towards an integrated survey system.

    Science.gov (United States)

    Karras, Bryant T; Wolpin, Seth; Lober, William B; Bush, Nigel; Fann, Jesse R; Berry, Donna L

    2006-01-01

    The Clinical Informatics Research Group and Biobehavioral Nursing and Health Systems at the University of Washington are working with interdisciplinary teams to improve patient care and tracking of patient-reported symptoms and outcomes by creating an extensible web-based survey and intervention platform. The findings and cumulative experience from these processes have led to incremental improvements and variations in each new implementation of the platform. This paper presents progress in the first year of a three-year NIH study entitled Electronic Self Report Assessment--Cancer (ESRA-C). The project's goals are to enhance and evaluate the web-based computerized patient self-reporting and assessment system at the Seattle Cancer Care Alliance. Preliminary work and lessons learned in the modification of the platform and enhancements to the system will be described.

  4. Final Report: Conceptual Design of an Electron Accelerator for Bio-Solid Waste Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Charles [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-09-20

    Several studies have identified electron beam (EB) irradiation of municipal wastewater and bio-solids as an effective and promising approach to the environmental remediation of the enormous quantities of human waste created by a growing world-wide population and increased urbanization. However, despite the technical success of experimental and pilot programs over the last several decades, the technique is still not in commercial use anywhere in the world. In addition, the report also identifies the need for “Financial and infrastructure participation from a utility for demonstration project” and “Education and awareness of safety of utilizing electron beam technology” as two additional roadblocks preventing technology adoption of EB treatment for bio-solids. In this concept design, we begin to address these barriers by working with Metropolitan Water Reclamation District of Greater Chicago (MWRD) and by the applying the latest accelerator technologies developed at Fermilab and within the DOE Office of Science laboratory complex.

  5. Advances and challenges in electron-molecule scattering physics-A Report of the 14th International Symposium on Electron-Molecule Collisions and Swarms

    Energy Technology Data Exchange (ETDEWEB)

    Khakoo, M A [Department of Physics, California State University, Fullerton, CA 92831 (United States); Lima, M A P [Departamento de Eletronica Quantica, Instituto de Fisica ' Gleb Wataghin' -UNICAMP, Caixa Postal 6165, 13083-970 Campinas (Brazil); Tennyson, J [Department of Physics and Astronomy, University College, Gower Street, London WC1E 6BT (United Kingdom)

    2006-07-15

    A report is presented of the 13th International Symposium on Electron-Molecule Collisions Physics (Instituto de Fisica, Unicamp, Campinas, Brazil, 27-30 July 2005). This workshop covered low-energy electron interactions with atoms, molecules and condensed matter systems. Several important aspects of this symposium were to bring together theory and experimental advances in this field for gaseous targets as well as showcasing the increasing diversity of electron-molecule collision applications in condensed matter and biological applications. A summary session was held wherein were discussed aspects of the future of the field, including the development of new theoretical and experimental capabilities.

  6. Improving patient-centered communication while using an electronic health record: Report from a curriculum evaluation.

    Science.gov (United States)

    Fogarty, Colleen T; Winters, Paul; Farah, Subrina

    2016-05-01

    Researchers and clinicians are concerned about the impact of electronic health record use and patient-centered communication. Training about patient-centered clinical communication skills with the electronic health record may help clinicians adapt and remain patient-centered. We developed an interactive workshop eliciting challenges and opportunities of working with the electronic health record in clinical practice, introduction of specific patient-centered behaviors and mindful practice techniques, and video demonstrating contrasts in common behavior and "better practices." One hundred thirty-nine resident physicians and faculty supervisors in five residency training programs at the University of Rochester Medical Center participated in the workshops. Participants were asked to complete an 11-item survey of behaviors related to their use of the electronic health record prior to training and after attending training. We used paired t-tests to assess changes in self-reported behavior from pre-intervention to post-intervention. We trained 139 clinicians in the workshops; 110 participants completed the baseline assessment and 39 completed both the baseline and post-intervention assessment. Data from post-curriculum respondents found a statistically significant increase in "I told the patient when turning my attention from the patient to the computer," from 60% of the time prior to the training to 70% of the time after. Data from our program evaluation demonstrated improvement in one communication behavior. Sample size limited the detection of other changes; further research should investigate effective training techniques for patient-centered communication while using the electronic health record. © The Author(s) 2016.

  7. Previously unknown species of Aspergillus.

    Science.gov (United States)

    Gautier, M; Normand, A-C; Ranque, S

    2016-08-01

    The use of multi-locus DNA sequence analysis has led to the description of previously unknown 'cryptic' Aspergillus species, whereas classical morphology-based identification of Aspergillus remains limited to the section or species-complex level. The current literature highlights two main features concerning these 'cryptic' Aspergillus species. First, the prevalence of such species in clinical samples is relatively high compared with emergent filamentous fungal taxa such as Mucorales, Scedosporium or Fusarium. Second, it is clearly important to identify these species in the clinical laboratory because of the high frequency of antifungal drug-resistant isolates of such Aspergillus species. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been shown to enable the identification of filamentous fungi with an accuracy similar to that of DNA sequence-based methods. As MALDI-TOF MS is well suited to the routine clinical laboratory workflow, it facilitates the identification of these 'cryptic' Aspergillus species at the routine mycology bench. The rapid establishment of enhanced filamentous fungi identification facilities will lead to a better understanding of the epidemiology and clinical importance of these emerging Aspergillus species. Based on routine MALDI-TOF MS-based identification results, we provide original insights into the key interpretation issues of a positive Aspergillus culture from a clinical sample. Which ubiquitous species that are frequently isolated from air samples are rarely involved in human invasive disease? Can both the species and the type of biological sample indicate Aspergillus carriage, colonization or infection in a patient? Highly accurate routine filamentous fungi identification is central to enhance the understanding of these previously unknown Aspergillus species, with a vital impact on further improved patient care. Copyright © 2016 European Society of Clinical Microbiology and

  8. National All Schedules Prescription Electronic Reporting Act (NASPER): balancing substance abuse and medical necessity.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Brown, Keith R; Singh, Vijay

    2002-07-01

    The National All Schedules Prescription Electronic Reporting Act, or NASPER, is a bill proposed by the American Society of Interventional Pain Physicians to provide and improve patient access with quality care, and protect patients and physicians from deleterious effects of controlled substance misuse, abuse and trafficking. Controlled prescription drugs, including narcotic analgesics, anxiolytics, anti-depressants, stimulants, and sedative-hypnotics play a significant and legitimate role in interventional pain management practices in managing chronic pain and related disorders. Based on the 1997 household survey on drug abuse it is estimated that 76.9 million Americans had used an illicit drug at least once in their life. In 1997, 4.2 million people used analgesics, 2.1 million used tranquillizers, and an additional 2.3 million people used various other drugs, including sedatives, tranquillizers, etc. The non-medical use of prescription drugs exceeds that of all illicit substances except for marijuana and hashish. The report on epidemiology trends in drug abuse, based on community epidemiology work group analysis showed continued increase of abuse of prescription drugs in urban, suburban, and rural areas. The most commonly abused drugs include oxycodone, hydrocodone, hydromorphone, morphine, codeine, clonazepam, alprazolam, lorazepam, diazepam and carisoprodol. The diversion of prescription controlled substances to illicit channels is a public health and safety issue. This review describes the role of controlled substances in chronic pain management, prevalence and economic impact of controlled substance abuse, prescription accountability, effectiveness of prescription monitoring programs, and rationale for national controlled substance electronic reporting system.

  9. The progress report of the Instrumentation and Technological Electronical Division, for 1987

    International Nuclear Information System (INIS)

    1988-05-01

    The 1987 activity report of the CEA Instrumentation and Technological Electronic Division (ITED), is presented. The ITED fields of interest include nuclear, space, health, defense and civil domains. The research development and perspectives are summarized. Concerning materials and components the following research programs are included: silicon integrated circuits, silicon on isolator, common experimental laboratory, mass memory, lasers, photodetection, flat screens, and sensors. In the field of instrumentations and systems, the retained research guidelines are focused on: medical and biological instrumentation, the environment, the nuclear domain. Moreover, the research fields of physics, artificial intelligence and software, production, robots, architecture and integration are also included [fr

  10. Data description and quality assessment of ionospheric electron density profiles for ARPA modeling project. Technical report

    International Nuclear Information System (INIS)

    Conkright, R.O.

    1977-03-01

    This report presents a description of the automated method used to produce electron density (N(h)) profiles from ionograms recorded on 35mm film and an assessment of the resulting data base. A large data base of about 30,000 profiles was required for an ionospheric modeling project. This motivated a search for an automated method of producing profiles. The automated method used is fully described, the resulting data are given a quality grade, and the noon and midnight profiles are presented. Selected portions of this data base are compared with profiles produced by the standard profiling method in use by the Environmental Data Service at Boulder, Colorado

  11. Summary Report of Consultants' Meeting on Auger Electron Emission Data Needs for Medical Applications

    International Nuclear Information System (INIS)

    Noy, Roberto Capote; Chung, Hyun Kyung; Bartschat, Klaus; Dong, Chenzhong; Jonsson, Per; Kibedi, Tibor; Kondev, Filip G.; Nikjoo, Hooshang; Palffy, Adriana

    2013-11-01

    A summary is given of a Consultants' Meeting on 'Auger Electron Emission Data Needs for Medical Applications'. Participants assessed and reviewed detailed atomic and nuclear data needs for a number of Auger emitters deemed as potentially suitable for applications in nuclear medicine and radiotherapy. Technical discussions are described in this report, along with recommendations for future work, along with recommendations for future work. Presentations by the consultants at the meeting are available at http://www-nds.iaea.org/index-meeting-crp/CM-Auger-2013/. (author)

  12. Medicare incentive payments for meaningful use of electronic health records: accounting and reporting developments.

    Science.gov (United States)

    2012-02-01

    The Healthcare Financial Management Association through its Principles and Practices (P&P) Board publishes issue analyses to provide short-term practical assistance on emerging issues in healthcare financial management. In a new issue analysis excerpted in this article, HFMA's P&P Board provides some clarity to the healthcare industry on certain accounting and reporting issues resulting from incentive payments under the Medicare program for the meaningful use of electronic health record (EHR) technology. Consultation on these matters with independent auditors is highly recommended.

  13. Accuracy and efficiency of radiologists reporting CT studies from a multiscreen electronic workstation

    International Nuclear Information System (INIS)

    Foley, W.D.; Lawson, T.L.; Erickson, S.J.

    1988-01-01

    This paper describes a limited picture archiving communication system linking, a via fiber optic cable, two computed tomographic (CT) scanners, and a double-screen (1,000-line monitors) display station with a 600-megabyte image memory evaluated for accuracy and efficiency in the generation of a radiology report. Twenty preselected CT studies (an average of 30 images per study, ten with prior examination for comparison) in cases with pathologically or clinically proved diagnoses were read by five radiologists, in random order, from both the electronic display console and conventional multiformat images. All cases were reread after 1-month interval in a different random order viewing sequence and the opposite viewing modality

  14. Electron affinity of UF6. Final report, March 1, 1976--June 30, 1977

    International Nuclear Information System (INIS)

    Rothe, E.W.

    1977-06-01

    Ionization reactions are observed in crossed molecular beams, usually of thermal energy, alkalis and MoF 6 , WF 6 and UF 6 . Previous studies have indicated large electron affinities for these hexafluorides, and this is confirmed here. Ionization at thermal energies proceeds with the alkali dimers, A 2 , for all three hexafluorides, but with alkali atoms, A, only for UF 6 . Several ionization paths are observed, allowing the deduction of molecular energies. A few experiments are done with eV-range beams. Lower limits for the elecron affinities are 4.5, 3.3, 4.9, 4.3 and 1.9 eV for MoF 6 , MoF 5 , WF 6 , UF 6 and UF 5 , respectively. Possible mechanisms are discussed

  15. Report of the Panel on Electron Accelerator Facilities, DOE/NSF Nuclear Science Advisory Committee

    International Nuclear Information System (INIS)

    1983-04-01

    This Panel finds that the highest priority for new accelerator construction in the US nuclear physics program is for an electron accelerator of high duty factor capable of producing beams at any energy in the range from 500 to 4000 MeV. After detailed study and consideration of the proposals for such facilities submitted to it, the Panel recommends: that the proposal submitted by the Southeastern University Research Association (SURA) be accepted and funded for the construction of a new National Electron Accelerator Laboratory (NEAL) centering on a 4 GeV linear accelerator-stretcher ring system capable of delivering intense, high duty factor, electron beams in the energy range from 500 to 4000 MeV. Additional recommendations relating to this principal one are to be found in the body of this report. As modified by the Panel consequent to its own studies and analyses, the estimated cost (in 1983 dollars) of the accelerator complex is 111.8 million dollars; of the entire laboratory is 146.8 million dollars; and the operating cost averaged over the first five years of operation is 18.1 million dollars per year. The projected 15 year total cost of the project is 418.3 million dollars. The construction period is estimated to be 4.5 years. The NEAL Laboratory, from the outset will be constructed and managed as a national rather than a regional facility and will provide the United States with a truly unique facility for research in electromagnetic physics

  16. Assessing electronic cigarette effects and regulatory impact: Challenges with user self-reported device power.

    Science.gov (United States)

    Rudy, Alyssa K; Leventhal, Adam M; Goldenson, Nicholas I; Eissenberg, Thomas

    2017-10-01

    Electronic cigarettes (ECIGs) aerosolize liquids for user inhalation that usually contain nicotine. ECIG nicotine emission is determined, in part, by user behavior, liquid nicotine concentration, and electrical power. Whether users are able to report accurately nicotine concentration and device electrical power has not been evaluated. This study's purpose was to examine if ECIG users could provide data relevant to understanding ECIG nicotine emission, particularly liquid nicotine concentration (mg/ml) as well as battery voltage (V) and heater resistance (ohms, Ω) - needed to calculate power (watts, W). Adult ECIG users (N=165) were recruited from Los Angeles, CA for research studies examining the effects of ECIG use. We asked all participants who visited the laboratory to report liquid nicotine concentration, V, and Ω. Liquid nicotine concentration was reported by 89.7% (mean=9.5mg/ml, SD=7.3), and responses were consistent with the distribution of liquids available in commonly marketed products. The majority could not report voltage (51.5%) or resistance (63.6%). Of the 40 participants (24.8%) who reported voltage and resistance, there was a substantial power range (2.2-32,670W) the upper limit of which exceeds that of the highest ECIG reported by any user to our knowledge (i.e., 2512W). If 2512W is taken as the upper limit, only 30 (18.2%) reported valid results (mean 237.3W, SD=370.6; range=2.2-1705.3W). Laboratory, survey, and other researchers interested in understanding ECIG effects to inform users and policymakers may need to use methods other than user self-report to obtain information regarding device power. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Considerations of beta and electron transport in internal dose calculations. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Bolch, W.E.

    1994-11-01

    The goal of this particular task is to consider, for the first time, the explicit transport of beta particles and photon-generated electrons in the series of six phantoms developed by Cristy and Eckerman (1987) at the Oak Ridge National Laboratory. In their report, ORNL/TM-8381, specific absorbed fractions of energy are reported for phantoms representing the newborn (3.4 kg), the one-year-old (9.8 kg), the five-year-old (19 kg), the ten-year-old (32 kg), the fifteen-year-old/adult female (55-58 kg), and the adult male (70 kg). Radiation transport calculations were performed with the Monte Carlo code ALGAMP which allows photon transport only. In subsequent calculations of radionuclide S values as is done in the MIRDOSE2 computer program, electron absorbed fractions are thus considered to be either unity or zero depending upon whether the source region does or does not equal the target region, respectively.

  18. DOE FreedomCAR and vehicle technologies program advanced power electronic and electrical machines annual review report

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Mitch [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2006-10-11

    This report is a summary of the Review Panel at the FY06 DOE FreedomCAR and Vehicle Technologies (FCVT) Annual Review of Advanced Power Electronics and Electric Machine (APEEM) research activities held on August 15-17, 2006.

  19. Epidemiological trends in electronic cigarette exposures reported to U.S. Poison Centers.

    Science.gov (United States)

    Vakkalanka, J P; Hardison, L S; Holstege, C P

    2014-06-01

    The Centers for Disease Control and Prevention (CDC) has reported an increase in electronic cigarette (e-cigarette) use in both adults and adolescents. Poison Center calls provide data on exposures pertaining to e-cigarette devices and components (including nicotine-refill cartridges), potentially identifying epidemiological trends in reported exposures over time. To characterize the trends in e-cigarette exposures reported to United States (U.S.) Poison Centers between 01 June 2010 and 30 September 2013. We obtained data from the American Association of Poison Control Centers (AAPCC) for all exposures involving e-cigarettes reported to the National Poison Data System (NPDS) by U.S. Poison Centers and described trends in exposures over time, demographics, geographical characteristics, clinical effects and outcomes, management site, and exposure route. A total of 1,700 exposures were reported to Poison Centers during this time. The most frequent age groups were children 5 years or below with 717 (42.2%) exposures and adults ages 20-39 years with 466 (27.4%) exposures. Temporal trends showed an increase of 1.36 exposures per month [95% CI: 1.16-1.56] from June 2010 through December 2012, after which exposures increased by 9.60 per month [95% CI: 8.64-10.55] from January through September 2013. The majority of patients who were followed reported that they had only minor effects. The majority of exposures to e-cigarette devices and components occurred in children of 5 years or below due to accidental exposure. Based on the available data, the reported exposures have resulted in minimal toxicity. Calls to Poison Centers regarding these products have rapidly increased since 2010, and continued surveillance may show changes in the epidemiological trends surrounding e-cigarette exposures.

  20. Use of remotely reporting electronic sensors for assessing use of water filters and cookstoves in Rwanda.

    Science.gov (United States)

    Thomas, Evan A; Barstow, Christina K; Rosa, Ghislaine; Majorin, Fiona; Clasen, Thomas

    2013-01-01

    Remotely reporting electronic sensors offer the potential to reduce bias in monitoring use of environmental health interventions. In the context of a five-month randomized controlled trial of household water filters and improved cookstoves in rural Rwanda, we collected data from intervention households on product compliance using (i) monthly surveys and direct observations by community health workers and environmental health officers, and (ii) sensor-equipped filters and cookstoves deployed for about two weeks in each household. The adoption rate interpreted by the sensors varied from the household reporting: 90.5% of households reported primarily using the intervention stove, while the sensors interpreted 73.2% use, and 96.5% of households reported using the intervention filter regularly, while the sensors interpreted no more than 90.2%. The sensor-collected data estimated use to be lower than conventionally collected data both for water filters (approximately 36% less water volume per day) and cookstoves (approximately 40% fewer uses per week). An evaluation of intrahousehold consistency in use suggests that households are not using their filters or stoves on an exclusive basis, and may be both drinking untreated water at times and using other stoves ("stove-stacking"). These results provide additional evidence that surveys and direct observation may exaggerate compliance with household-based environmental interventions.

  1. A novel biotinylated lipid raft reporter for electron microscopic imaging of plasma membrane microdomains[S

    Science.gov (United States)

    Krager, Kimberly J.; Sarkar, Mitul; Twait, Erik C.; Lill, Nancy L.; Koland, John G.

    2012-01-01

    The submicroscopic spatial organization of cell surface receptors and plasma membrane signaling molecules is readily characterized by electron microscopy (EM) via immunogold labeling of plasma membrane sheets. Although various signaling molecules have been seen to segregate within plasma membrane microdomains, the biochemical identity of these microdomains and the factors affecting their formation are largely unknown. Lipid rafts are envisioned as submicron membrane subdomains of liquid ordered structure with differing lipid and protein constituents that define their specific varieties. To facilitate EM investigation of inner leaflet lipid rafts and the localization of membrane proteins therein, a unique genetically encoded reporter with the dually acylated raft-targeting motif of the Lck kinase was developed. This reporter, designated Lck-BAP-GFP, incorporates green fluorescent protein (GFP) and biotin acceptor peptide (BAP) modules, with the latter allowing its single-step labeling with streptavidin-gold. Lck-BAP-GFP was metabolically biotinylated in mammalian cells, distributed into low-density detergent-resistant membrane fractions, and was readily detected with avidin-based reagents. In EM images of plasma membrane sheets, the streptavidin-gold-labeled reporter was clustered in 20–50 nm microdomains, presumably representative of inner leaflet lipid rafts. The utility of the reporter was demonstrated in an investigation of the potential lipid raft localization of the epidermal growth factor receptor. PMID:22822037

  2. Does electronic clinical microbiology results reporting influence medical decision making: a pre- and post-interview study of medical specialists.

    Science.gov (United States)

    Bruins, Marjan J; Ruijs, Gijs J H M; Wolfhagen, Maurice J H M; Bloembergen, Peter; Aarts, Jos E C M

    2011-03-30

    Clinicians view the accuracy of test results and the turnaround time as the two most important service aspects of the clinical microbiology laboratory. Because of the time needed for the culturing of infectious agents, final hardcopy culture results will often be available too late to have a significant impact on early antimicrobial therapy decisions, vital in infectious disease management. The clinical microbiologist therefore reports to the clinician clinically relevant preliminary results at any moment during the diagnostic process, mostly by telephone. Telephone reporting is error prone, however. Electronic reporting of culture results instead of reporting on paper may shorten the turnaround time and may ensure correct communication of results. The purpose of this study was to assess the impact of the implementation of electronic reporting of final microbiology results on medical decision making. In a pre- and post-interview study using a semi-structured design we asked medical specialists in our hospital about their use and appreciation of clinical microbiology results reporting before and after the implementation of an electronic reporting system. Electronic reporting was highly appreciated by all interviewed clinicians. Major advantages were reduction of hardcopy handling and the possibility to review results in relation to other patient data. Use and meaning of microbiology reports differ significantly between medical specialties. Most clinicians need preliminary results for therapy decisions quickly. Therefore, after the implementation of electronic reporting, telephone consultation between clinician and microbiologist remained the key means of communication. Overall, electronic reporting increased the workflow efficiency of the medical specialists, but did not have an impact on their decision-making. © 2011 Bruins et al; licensee BioMed Central Ltd.

  3. Does electronic clinical microbiology results reporting influence medical decision making: a pre- and post-interview study of medical specialists

    Directory of Open Access Journals (Sweden)

    Bloembergen Peter

    2011-03-01

    Full Text Available Abstract Background Clinicians view the accuracy of test results and the turnaround time as the two most important service aspects of the clinical microbiology laboratory. Because of the time needed for the culturing of infectious agents, final hardcopy culture results will often be available too late to have a significant impact on early antimicrobial therapy decisions, vital in infectious disease management. The clinical microbiologist therefore reports to the clinician clinically relevant preliminary results at any moment during the diagnostic process, mostly by telephone. Telephone reporting is error prone, however. Electronic reporting of culture results instead of reporting on paper may shorten the turnaround time and may ensure correct communication of results. The purpose of this study was to assess the impact of the implementation of electronic reporting of final microbiology results on medical decision making. Methods In a pre- and post-interview study using a semi-structured design we asked medical specialists in our hospital about their use and appreciation of clinical microbiology results reporting before and after the implementation of an electronic reporting system. Results Electronic reporting was highly appreciated by all interviewed clinicians. Major advantages were reduction of hardcopy handling and the possibility to review results in relation to other patient data. Use and meaning of microbiology reports differ significantly between medical specialties. Most clinicians need preliminary results for therapy decisions quickly. Therefore, after the implementation of electronic reporting, telephone consultation between clinician and microbiologist remained the key means of communication. Conclusions Overall, electronic reporting increased the workflow efficiency of the medical specialists, but did not have an impact on their decision-making.

  4. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  5. Government leadership in addressing public health priorities: strides and delays in electronic laboratory reporting in the United States.

    Science.gov (United States)

    Gluskin, Rebecca Tave; Mavinkurve, Maushumi; Varma, Jay K

    2014-03-01

    For nearly a decade, interest groups, from politicians to economists to physicians, have touted digitization of the nation's health information. One frequently mentioned benefit is the transmission of information electronically from laboratories to public health personnel, allowing them to rapidly analyze and act on these data. Switching from paper to electronic laboratory reports (ELRs) was thought to solve many public health surveillance issues, including workload, accuracy, and timeliness. However, barriers remain for both laboratories and public health agencies to realize the full benefits of ELRs. The New York City experience highlights several successes and challenges of electronic reporting and is supported by peer-reviewed literature. Lessons learned from ELR systems will benefit efforts to standardize electronic medical records reporting to health departments.

  6. Electronics department progress report. Basic and applied research activity 1975-1977

    International Nuclear Information System (INIS)

    1978-10-01

    The electronics department at Risoe National Laboratory, Denmark, comprises about 80 people and is made up of essentially two main divisions. One deals with the provision of instrumentation and measurement expertise for the different groups at Risoe who conduct basic research or technological R and D. This division employs a group of scientific electronics consultants, a production group, a maintenance facility and a central instrument pool for the complete site. The other division, whose work is reported here, is engaged in both basic and applied research in topics and areas of direct interest to the department itself. These involve the development and evaluation of methods, for example, in the field of plant reliability and safety as well as in a group engaged in nuclear geophysical activities - including mineral prospecting in Greenland. Another team is working with man-machine problems in highly automated systems and the associated needs for computer support in connection with proper job allocation and design. Finally, a group is active in the field of applied laser physics. The time period covered is 1975-1977. (author/BP)

  7. The Public Health Community Platform, Electronic Case Reporting, and the Digital Bridge.

    Science.gov (United States)

    Cooney, Mary Ann; Iademarco, Michael F; Huang, Monica; MacKenzie, William R; Davidson, Arthur J

    At the intersection of new technology advancements, ever-changing health policy, and fiscal constraints, public health agencies seek to leverage modern technical innovations and benefit from a more comprehensive and cooperative approach to transforming public health, health care, and other data into action. State health agencies recognized a way to advance population health was to integrate public health with clinical health data through electronic infectious disease case reporting. The Public Health Community Platform (PHCP) concept of bidirectional data flow and knowledge management became the foundation to build a cloud-based system connecting electronic health records to public health data for a select initial set of notifiable conditions. With challenges faced and lessons learned, significant progress was made and the PHCP grew into the Digital Bridge, a national governance model for systems change, bringing together software vendors, public health, and health care. As the model and technology advance together, opportunities to advance future connectivity solutions for both health care and public health will emerge.

  8. Experiments on the nuclear interactions of pion and electrons. Final progress report

    International Nuclear Information System (INIS)

    Minehart, R.C.

    1998-05-01

    The work in this report is grouped into four categories. (1) The experiments in pion nucleus physics were primarily studies of pion absorption and scattering in light nuclei, carried out at the Los Alamos Meson Physics Facility (LAMPF). (2) The experiments on fundamental particle properties were carried out at LAMPF and at the Paul Scherrer Institute (PSI) in Switzerland, the pion-beta decay experiment is still under construction and will begin taking data in 1999. (3) The experiments in electro-nuclear physics were performed at the Stanford Linear Electron Accelerator (SLAC), at the Saclay Laboratory in France, at the LEGS facility at the Brookhaven National Laboratory, and at the Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Laboratory. These experiments relate mainly to the question of the role of longitudinal and transverse strength for inelastic scattering from nuclei, measurements of fundamental nuclear properties with tagged polarized photons, and to the quark structure of the nucleon and its excited states. (4) Experiments on absorption of antiprotons in heavy nuclei, were carried out by K. Ziock primarily while on a sabbatical leave in Munich, Germany

  9. Research on cw electron accelerators using room-temperature rf structures. Annual report

    International Nuclear Information System (INIS)

    1985-01-01

    Highlights reported include: measurement of the 100 keV chopped beam emittance, completion of installation of the entire 5 MeV injector linac system with all rf power and drive, extensive field mapping of one end magnet, completion of construction of the 12 MeV linac for the racetrack microtron (RTM), installation of most of the control system, and first acceleration of beam to 5 MeV. Plans for completion of the project are discussed. When the RTM is operating, it is expected to have many unique performance characteristics, including the cw nature of the beam, high current, easily variable energy over a wide range, excellent emittance, and small energy spread. Plans for future uses in the areas of nuclear physics, dosimetry research and standards, accelerator development, and free electron laser research are discussed. 19 refs

  10. Electron transfer processes in ion collisions with atomic hydrogen. Final report for period February 1, 1975--June 30, 1976

    International Nuclear Information System (INIS)

    Bayfield, J.E.

    1976-07-01

    Results of experiments completed with Yale equipment coupled to the Oak Ridge Test Bench and Tandem Accelerator facilities are presented. Electron transfer cross sections have been measured at keV collision energies for B, C, N and O ions colliding with H, H 2 , Ar and He gas targets. The ion charge states studied range from +2 through +5. Also reported are cross sections for Si and Fe ions on H, H 2 and Ar at energies between 1.5 and 14 MeV, with charge states varying between +5 and +13. Also measured were the cross sections for H + collisions with H, H 2 and Ar for energies between 0.8 and 2.5 MeV. At keV energies the cross sections for highly charged B, C, N and O ions are found to be 1 x 10 -14 cm 2 . The cross sections for 4 MeV Fe ions scale roughly with the square of the ion charge, and have values as high as 0.5 x 10 -14 cm 2 for Fe 10+ + H collisions. A strong energy dependence is found for Fe ion collisions between 4 and 14 MeV. Previous results for MeV H + + Ar collisions are nicely reproduced, while our first results for the fundamental MeV H + - H collision problem are cross sections higher than many theoretical predictions

  11. Clinical outcomes of the inclusion of the therapeutic drug monitoring report in the electronic clinical record

    Directory of Open Access Journals (Sweden)

    Marina Sáez Belló

    2016-12-01

    Full Text Available Objectives: To assess the inclusion of the Therapeutic Drug Monitoring Report (TDMR in the Electronic Clinical Record (ECR. Method: An observational ambispective cohort study with a duration of 149 days: PRE (retrospective, 49 days with the TDMR printed in paper, and POST (prospective, 100 days with the TDMR included in the ECR. Exclusion criteria: Patients not hospitalized, applications for Therapeutic Drug Monitoring by Critical Care and Neonatal Units, as well as monitoring with an objective other than dose adjustment. Variables: Number of TDMRs prepared, number of patients admitted with TDMR, time of delay for treatment adjustment, defined as the number of adjustments made to the treatment within over or under 24 hours from the time of TDMR preparation, and medication errors (MEs associated with said delay, as well as the degree of acceptance of the TDMR. Results: 690 TDMRs were conducted in 391 patients, 339 in PRE (n = 206 and 351 in POST (n = 185. The number of treatment modifications made in under 24 hours increased from 73.9% in PRE to 87.3% in POST [RR = 1.2 (CI95% = 0.97-1.43. We identified 35 patients with ME, 9.7% of them in PRE and 8.1% in POST (RR = 0.84 (CI95% = 0.44-1.58]. The degree of acceptance of the pharmacist recommendation increased from 53.3% in PRE to 68.3% in POST [RR = 1.3 (CI95% = 1.02- 1.62]. Conclusions: The inclusion of the Therapeutic Drug Monitoring Report (TDMR in the Electronic Clinical Record increases the degree of acceptance of recommendations, and may reduce the delay in treatment modifications, reducing MEs and improving the process quality in terms of efficacy and safety

  12. FY2009 Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Mitchell [ORNL

    2009-11-01

    environment or as a complete propulsion system and whether the efficiency and performance targets at the vehicle level have been achieved. The research performed under this subprogram will help remove technical and cost barriers to enable the development of technology for use in such advanced vehicles as hybrid electric vehicles (HEVs), plug-in HEVs (PHEVs), all electric vehicles, and fuel-cell-powered automobiles that meet the goals of the Vehicle Technologies Program. A key element in making these advanced vehicles practical is providing an affordable electric traction drive system. This will require attaining weight, volume, and cost targets for the power electronics and electrical machines subsystems of the traction drive system. Areas of development include these: (1) novel traction motor designs that result in increased power density and lower cost; (2) inverter technologies involving new topologies to achieve higher efficiency, with the ability to accommodate higher-temperature environments while achieving high reliability; (3) converter concepts that employ means of reducing the component count and integrating functionality to decrease size, weight, and cost; (4) new onboard battery charging concepts that result in decreased cost and size; (5) more effective thermal control and packaging technologies; and (6) integrated motor/inverter concepts. ORNL's Power Electronics and Electric Machinery Research Center conducts fundamental research, evaluates hardware, and assists in the technical direction of the DOE Vehicle Technologies Program, APEEM subprogram. In this role, ORNL serves on the FreedomCAR Electrical and Electronics Technical Team, evaluates proposals for DOE, and lends its technological expertise to the direction of projects and evaluation of developing technologies. ORNL also executes specific projects for DOE. The following report discusses those projects carried out in FY 2009 and conveys highlights of their accomplishments. Numerous project reviews

  13. All together now: findings from a PCORI workshop to align patient-reported outcomes in the electronic health record.

    Science.gov (United States)

    Jensen, Roxanne E; Snyder, Claire F; Basch, Ethan; Frank, Lori; Wu, Albert W

    2016-11-01

    In recent years, patient-reported outcomes have become increasingly collected and integrated into electronic health records. However, there are few cross-cutting recommendations and limited guidance available in this rapidly developing research area. Our goal is to report key findings from a 2013 Patient-Centered Outcomes Research Institute workshop on this topic and a summary of actions that followed from the workshop, and present resulting recommendations that address patient, clinical and research/quality improvement barriers to regular use. These findings provide actionable guidance across research and practice settings to promote and sustain widespread adoption of patient-reported outcomes across patient populations, healthcare settings and electronic health record systems.

  14. Preliminary report on electron energy-loss measurements for CCl3, CCl2F2, CCl3F

    International Nuclear Information System (INIS)

    Bushnell, D.L. Jr.; Huebner, R.H.; Celotta, R.J.; Mielczarek, S.R.

    1975-01-01

    Currently, nation-wide research efforts are devoted to studying the possible ozone (O 3 ) depletion in the stratosphere by the chemical action of chlorine atoms released from CCl 2 F 2 or CCl 3 F upon absorption of ultraviolet radiation. Since electron-impact data taken in the forward scattering direction can be used to derive oscillator strengths and thus to yield apparent photoabsorption cross sections, such an analysis for CCl 2 F 2 , CCLl 3 F, and CClF 3 was carried out. Oscillator-strength distributions were obtained between 5 and 20 eV and are compared to available photoabsorption data. Certain photoabsorption values agree very well with these electron-impact data, but other optical studies deviate in some spectral regions by as much as a factor of 5. Also, the electron energy-loss spectrum reveals electronic transitions previously undetected by photoabsorption

  15. Final report for the Department of Energy funded cooperative agreement ''Electronic Research Demonstration Project'' [University electronic research administration demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Rodman, John

    1998-07-31

    This is the final report for the Department of Energy (DOE) funded cooperative agreement ''Electronic Research Demonstration Project (DE-FC02-92ER35180)'' for the period August 1994-July 1998. The goal of the project, referred to as NewERA, was to demonstrate the use of open standards for electronic commerce to support research administration, otherwise referred to as Electronic Research Administration (ERA). The NewERA demonstration project provided a means to test interagency standards developed within the Federal Grant Electronic Commerce Committee, a group comprised of federal granting agencies. The NewERA program was initiated by DOE. NewERA was comprised of three separate, but related, ERA activities in preaward administration, postaward administration, and secure Internet commerce. The goal of New ERA was to demonstrate an open standard implementation of ERA using electronic data interchange, e-mail and Internet transaction security between grant applicants and DOE, along with t h e other participating agencies.

  16. Electron beam fusion (a bibliography with abstracts). Report for 1964--Oct 1975

    International Nuclear Information System (INIS)

    Grooms, D.W.

    1975-10-01

    The bibliography cites research on using electron beams to initiate fusion. Theoretical and experimental research concerned with the generation and dynamics of relativistic electron beams and their interaction with high atomic number materials is included

  17. Summary Report about the Sustainable Materials Management (SMM) Electronics Reuse and Recycling Forum

    Science.gov (United States)

    On September 23 and 24, 2014, EPA hosted a forum to “harness the collective power of the electronics community and identify shared priorities that will advance domestic end-of-life electronics management.

  18. Electron hybridization effects and the crystal structure of plutonium: Progress report, January 1, 1987--May 31, 1988

    International Nuclear Information System (INIS)

    Cooper, B.R.

    1988-01-01

    The main research effort during the past year was on the theory of surface electronic behavior of plutonium. This research was described in last year's Progress Report and deals with both development of the resonant band-f scattering theory for the magnetic properties of highly correlated actinide systems and the synthesis of band and model Hamiltonian theory for actinide systems. A summary of the results for the surface electronic behavior of plutonium are included

  19. Subsequent childbirth after a previous traumatic birth.

    Science.gov (United States)

    Beck, Cheryl Tatano; Watson, Sue

    2010-01-01

    Nine percent of new mothers in the United States who participated in the Listening to Mothers II Postpartum Survey screened positive for meeting the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria for posttraumatic stress disorder after childbirth. Women who have had a traumatic birth experience report fewer subsequent children and a longer length of time before their second baby. Childbirth-related posttraumatic stress disorder impacts couples' physical relationship, communication, conflict, emotions, and bonding with their children. The purpose of this study was to describe the meaning of women's experiences of a subsequent childbirth after a previous traumatic birth. Phenomenology was the research design used. An international sample of 35 women participated in this Internet study. Women were asked, "Please describe in as much detail as you can remember your subsequent pregnancy, labor, and delivery following your previous traumatic birth." Colaizzi's phenomenological data analysis approach was used to analyze the stories of the 35 women. Data analysis yielded four themes: (a) riding the turbulent wave of panic during pregnancy; (b) strategizing: attempts to reclaim their body and complete the journey to motherhood; (c) bringing reverence to the birthing process and empowering women; and (d) still elusive: the longed-for healing birth experience. Subsequent childbirth after a previous birth trauma has the potential to either heal or retraumatize women. During pregnancy, women need permission and encouragement to grieve their prior traumatic births to help remove the burden of their invisible pain.

  20. Raman scattering and associated fast electron production. Final technical report, April 16, 1984-April 15, 1985

    International Nuclear Information System (INIS)

    Brooks, R.D.; Pietrzyk, Z.A.

    1985-08-01

    High energy electrons in plasmas have been attributed to various causes including trapping by electron plasma waves created by stimulated Raman scattering. A theory, consistent with experimental results, based on the acceleration of trapped electrons by such electron plasma waves as they propagate in the presence of a density gradient away from the region where they are created is presented. Single particle simulations show accelerating voltages as high as 20 GV/m

  1. Theory of electron--photon scattering effects in metals. Progress report, December 1, 1976--November 30, 1977

    International Nuclear Information System (INIS)

    Lawrence, W.E.

    1977-01-01

    The general areas in which the investigations were carried out are transport properties and quasiparticle lifetimes in normal metals and superconductors. The more specific research projects upon which progress is reported are (a) the calculation of order parameter relaxation times in aluminum, (b) transport coefficients of the noble metals (emphasizing deviations from Matthiessen's rule), (c) variational transport calculations for a superconductor, (d) some general results on quasiparticle relaxation time anisotropy in polyvalent metals, and (e) a clarification of the roles of electron-electron and electron-phonon scattering in somple metals at low temperatures

  2. Electron beam treatment of organic pollutants contained in gaseous streams. 1. RCM report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    provides background information followed by information on health risks associated with volatile organic compounds (VOCS), areas of development, laboratory and pilot scale research work, electron beam fuel gas purification technology - up-scaling and development, CRP overall objective, network collaboration and the workplan. The executive summary ends with conclusions and recommendations followed by 13 individual reports of participating countries. They are indexed separately.

  3. Electron beam treatment of organic pollutants contained in gaseous streams. 1. RCM report

    International Nuclear Information System (INIS)

    2005-01-01

    provides background information followed by information on health risks associated with volatile organic compounds (VOCS), areas of development, laboratory and pilot scale research work, electron beam fuel gas purification technology - up-scaling and development, CRP overall objective, network collaboration and the workplan. The executive summary ends with conclusions and recommendations followed by 13 individual reports of participating countries. They are indexed separately

  4. Gender disparities in the experience, effects and reporting of electronic aggression among secondary school students in Nigeria.

    Science.gov (United States)

    Olumide, Adesola O; Adebayo, Emmanuel; Oluwagbayela, Babatunde

    2016-01-01

    Electronic aggression is the use of electronic communication technologies to harass others. It is a problem among adolescents and young people worldwide. There is a dearth of information on this problem in developing countries in spite of the increasing use of electronic media technology in these countries. To explore gender differences in the prevalence, effects and reporting of electronic aggression among secondary school students in Oyo state, Nigeria. A cross-sectional study was conducted using mixed methods (a quantitative survey of 653 students and 18 in-depth interviews with victims and/or perpetrators). Survey students were selected using multi-stage sampling and in-depth interviewees were selected purposively. History of electronic aggression (as a perpetrator and/or victim) in the 3 months preceding the study was obtained. Respondents also provided information on the effects of the last incident of bullying on them and whether or not they reported this incident. 25.8% of males and 22.1% of females had perpetrated electronic aggression, while 42.7% of females were victims compared to 36.8% of males. More females (58.1%) than males (40.3%) perpetrated electronic aggression via phone calls and more males (33.8%) than females (22.6%) perpetrated electronic aggression via chatrooms. 45.4% of male victims and 39.4% of female victims felt angry following the last cyberbully incident. Findings from the in-depth interviewees corroborated the survey findings and a male victim reported feeling very sad and even tried to stay away from school following repeated episodes of electronic aggression. More female (59.1%) than male (42.7%) victims reported the incident to someone (p=0.035). Incidents of electronic aggression were common and the experiences of male and female students were comparable, although more female victims reported the incidents they had experienced. Victims, especially males, should be encouraged to report incidents so that the relevant authorities

  5. Mobile electronic versus paper case report forms in clinical trials: a randomized controlled trial.

    Science.gov (United States)

    Fleischmann, Robert; Decker, Anne-Marie; Kraft, Antje; Mai, Knut; Schmidt, Sein

    2017-12-01

    Regulations, study design complexity and amounts of collected and shared data in clinical trials render efficient data handling procedures inevitable. Recent research suggests that electronic data capture can be key in this context but evidence is insufficient. This randomized controlled parallel group study tested the hypothesis that time efficiency is superior when electronic (eCRF) instead of paper case report forms (pCRF) are used for data collection. We additionally investigated predictors of time saving effects and data integrity. This study was conducted on top of a clinical weight loss trial performed at a clinical research facility over six months. All study nurses and patients participating in the clinical trial were eligible to participate and randomly allocated to enter cross-sectional data obtained during routine visits either through pCRF or eCRF. A balanced randomization list was generated before enrolment commenced. 90 and 30 records were gathered for the time that 27 patients and 2 study nurses required to report 2025 and 2037 field values, respectively. The primary hypothesis, that eCRF use is faster than pCRF use, was tested by a two-tailed t-test. Analysis of variance and covariance were used to evaluate predictors of entry performance. Data integrity was evaluated by descriptive statistics. All randomized patients were included in the study (eCRF group n = 13, pCRF group n = 14). eCRF, as compared to pCRF, data collection was associated with significant time savings  across all conditions (8.29 ± 5.15 min vs. 10.54 ± 6.98 min, p = .047). This effect was not defined by participant type, i.e. patients or study nurses (F (1,112)  = .15, p = .699), CRF length (F (2,112)  = .49, p = .609) or patient age (Beta = .09, p = .534). Additional 5.16 ± 2.83 min per CRF were saved with eCRFs due to data transcription redundancy when patients answered questionnaires directly in eCRFs. Data integrity was

  6. Final Report for 'Modeling Electron Cloud Diagnostics for High-Intensity Proton Accelerators'

    International Nuclear Information System (INIS)

    Veitzer, Seth A.

    2009-01-01

    Electron clouds in accelerators such as the ILC degrade beam quality and limit operating efficiency. The need to mitigate electron clouds has a direct impact on the design and operation of these accelerators, translating into increased cost and reduced performance. Diagnostic techniques for measuring electron clouds in accelerating cavities are needed to provide an assessment of electron cloud evolution and mitigation. Accurate numerical modeling of these diagnostics is needed to validate the experimental techniques. In this Phase I, we developed detailed numerical models of microwave propagation through electron clouds in accelerating cavities with geometries relevant to existing and future high-intensity proton accelerators such as Project X and the ILC. Our numerical techniques and simulation results from the Phase I showed that there was a high probability of success in measuring both the evolution of electron clouds and the effects of non-uniform electron density distributions in Phase II.

  7. Final Report: Novel Nanowires as Probes of Electron Coherence and Correlations in Restricted Geometries

    International Nuclear Information System (INIS)

    Natelson, Douglas

    2005-01-01

    This is a final summary report of the research conducted under DE-FG03-01ER45946, which was a research program using metal nanostructures to examine quantum coherence of electrons in normal and ferromagnetic metals. This program was the PI's first federal research grant, and by augmenting with other funds (Packard Foundation), this grant supported two graduate students during its duration. In normal metal nanostructures, quantum coherence was assessed by two independent techniques: weak localization magnetoresistance, and time-dependent universal conductance fluctuations (TDUCF noise). This work found that, in AuPd nanowires, the coherence information inferred from these two techniques were quantitatively consistent, even in the presence of magnetic impurity and phonon scattering. This confirmed theoretical expectations. However, in Ag and Au wires, the two techniques disagree, with noise measurements indicating a lower coherence length at low temperatures than weak localization. We have a candidate explanation for this, and are finishing these experiments. This work shows that subtleties remain in our understanding of coherence processes even in normal metals, particularly those involving the tunneling two-level systems that produce low frequency noise; this has relevance for quantum information processing implementations using metal devices. We have also studied time-dependent universal conductance fluctuations in ferromagnetic metals for the first time. The TDUCF in ferromagnetic nanowires show that the Cooperon channel of coherent processes is suppressed in these correlated materials. Furthermore, the surprisingly steep temperature dependence of the noise suggests that decoherence in these systems is through a different process than in normal metals. We are finishing measurements of ''magnetofingerprint'' conductance fluctuations in ferromagnetic metals to examine this unusual temperature dependence with an independent technique. This program has produced three

  8. Electronic patient-reported data capture as a foundation of rapid learning cancer care.

    Science.gov (United States)

    Abernethy, Amy P; Ahmad, Asif; Zafar, S Yousuf; Wheeler, Jane L; Reese, Jennifer Barsky; Lyerly, H Kim

    2010-06-01

    "Rapid learning healthcare" presents a new infrastructure to support comparative effectiveness research. By leveraging heterogeneous datasets (eg, clinical, administrative, genomic, registry, and research), health information technology, and sophisticated iterative analyses, rapid learning healthcare provides a real-time framework in which clinical studies can evaluate the relative impact of therapeutic approaches on a diverse array of measures. This article describes an effort, at 1 academic medical center, to demonstrate what rapid learning healthcare might look like in operation. The article describes the process of developing and testing the components of this new model of integrated clinical/research function, with the pilot site being an academic oncology clinic and with electronic patient-reported outcomes (ePROs) being the foundational dataset. Steps included: feasibility study of the ePRO system; validation study of ePRO collection across 3 cancers; linking ePRO and other datasets; implementation; stakeholder alignment and buy in, and; demonstration through use cases. Two use cases are presented; participants were metastatic breast cancer (n = 65) and gastrointestinal cancer (n = 113) patients at 2 academic medical centers. (1) Patient-reported symptom data were collected with tablet computers; patients with breast and gastrointestinal cancer indicated high levels of sexual distress, which prompted multidisciplinary response, design of an intervention, and successful application for funding to study the intervention's impact. (2) The system evaluated the longitudinal impact of a psychosocial care program provided to patients with breast cancer. Participants used tablet computers to complete PRO surveys; data indicated significant impact on psychosocial outcomes, notably distress and despair, despite advanced disease. Results return to the clinic, allowing iterative update and evaluation. An ePRO-based rapid learning cancer clinic is feasible, providing

  9. Status report on front end electronics for the EUSO photon detector

    International Nuclear Information System (INIS)

    Bosson, G.; Dzahini, D.; Koang, D.H.; Musico, P.; Pallavicini, M.; Pouxe, J.; Pratolongo, F.; Richer, J.P.

    2002-01-01

    In this paper we'll give a status report on the design of the front end electronic system which will be used for the EUSO photon detector. For space, mass and power consumption constraints the system will be implemented developing an ASIC chip using a deep submicron technology. Two complementary approaches will be described: a digital one (DFEE) and an analog one (AFEE). The DFEE is able to count the single photoelectrons coming form the detector, store the numbers in a memory buffer and read them out after a trigger using a serial communication line. The AFEE integrate the anode signals, store them in an analog memory and serially send all the values to a single output after a trigger for digitalisation (external to the chip). Since the approaches are complementary the idea is to put both of them in the final front end chip. An overview of the system is given together to the actual status of the design. Results from simulations are shown: the system is feasible and we think to implement some devices this year to extensively test the proposed solutions

  10. Status report on front end electronics for the EUSO photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Bosson, G.; Dzahini, D.; Koang, D.H.; Musico, P.; Pallavicini, M.; Pouxe, J.; Pratolongo, F.; Richer, J.P

    2002-12-01

    In this paper we'll give a status report on the design of the front end electronic system which will be used for the EUSO photon detector. For space, mass and power consumption constraints the system will be implemented developing an ASIC chip using a deep submicron technology. Two complementary approaches will be described: a digital one (DFEE) and an analog one (AFEE). The DFEE is able to count the single photoelectrons coming form the detector, store the numbers in a memory buffer and read them out after a trigger using a serial communication line. The AFEE integrate the anode signals, store them in an analog memory and serially send all the values to a single output after a trigger for digitalisation (external to the chip). Since the approaches are complementary the idea is to put both of them in the final front end chip. An overview of the system is given together to the actual status of the design. Results from simulations are shown: the system is feasible and we think to implement some devices this year to extensively test the proposed solutions.

  11. Electron Beam Melting Manufacturing Technology for Individually Manufactured Jaw Prosthesis: A Case Report.

    Science.gov (United States)

    Suska, Felicia; Kjeller, Göran; Tarnow, Peter; Hryha, Eduard; Nyborg, Lars; Snis, Anders; Palmquist, Anders

    2016-08-01

    In the field of maxillofacial reconstruction, additive manufacturing technologies, specifically electron beam melting (EBM), offer clinicians the potential for patient-customized design of jaw prostheses, which match both load-bearing and esthetic demands. The technique allows an innovative, functional design, combining integrated porous regions for bone ingrowth and secondary biological fixation with solid load-bearing regions ensuring the biomechanical performance. A patient-specific mandibular prosthesis manufactured using EBM was successfully used to reconstruct a patient's mandibular defect after en bloc resection. Over a 9-month follow-up period, the patient had no complications. A short operating time, good esthetic outcome, and high level of patient satisfaction as measured by quality-of-life questionnaires-the European Organisation for Research and Treatment of Cancer QLQ-C30 (30-item quality-of-life core questionnaire) and H&N35 (head and neck cancer module)-were reported for this case. Individually planned and designed EBM-produced prostheses may be suggested as a possible future alternative to fibular grafts or other reconstructive methods. However, the role of porosity, the role of geometry, and the optimal combination of solid and porous parts, as well as surface properties in relation to soft tissues, should be carefully evaluated in long-term clinical trials. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  13. Final Report - Composite Fermion Approach to Strongly Interacting Quasi Two Dimensional Electron Gas Systems

    Energy Technology Data Exchange (ETDEWEB)

    Quinn, John

    2009-11-30

    Work related to this project introduced the idea of an effective monopole strength Q* that acted as the effective angular momentum of the lowest shell of composite Fermions (CF). This allowed us to predict the angular momentum of the lowest band of energy states for any value of the applied magnetic field simply by determining N{sub QP} the number of quasielectrons (QE) or quasiholes (QH) in a partially filled CF shell and adding angular momenta of the N{sub QP} Fermions excitations. The approach reported treated the filled CF level as a vacuum state which could support QE and QH excitations. Numerical diagonalization of small systems allowed us to determine the angular momenta, the energy, and the pair interaction energies of these elementary excitations. The spectra of low energy states could then be evaluated in a Fermi liquid-like picture, treating the much smaller number of quasiparticles and their interactions instead of the larger system of N electrons with Coulomb interactions.

  14. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  15. Impact of a reengineered electronic error-reporting system on medication event reporting and care process improvements at an urban medical center.

    Science.gov (United States)

    McKaig, Donald; Collins, Christine; Elsaid, Khaled A

    2014-09-01

    A study was conducted to evaluate the impact of a reengineered approach to electronic error reporting at a 719-bed multidisciplinary urban medical center. The main outcome of interest was the monthly reported medication errors during the preimplementation (20 months) and postimplementation (26 months) phases. An interrupted time series analysis was used to describe baseline errors, immediate change following implementation of the current electronic error-reporting system (e-ERS), and trend of error reporting during postimplementation. Errors were categorized according to severity using the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) Medication Error Index classifications. Reported errors were further analyzed by reporter and error site. During preimplementation, the monthly reported errors mean was 40.0 (95% confidence interval [CI]: 36.3-43.7). Immediately following e-ERS implementation, monthly reported errors significantly increased by 19.4 errors (95% CI: 8.4-30.5). The change in slope of reported errors trend was estimated at 0.76 (95% CI: 0.07-1.22). Near misses and no-patient-harm errors accounted for 90% of all errors, while errors that caused increased patient monitoring or temporary harm accounted for 9% and 1%, respectively. Nurses were the most frequent reporters, while physicians were more likely to report high-severity errors. Medical care units accounted for approximately half of all reported errors. Following the intervention, there was a significant increase in reporting of prevented errors and errors that reached the patient with no resultant harm. This improvement in reporting was sustained for 26 months and has contributed to designing and implementing quality improvement initiatives to enhance the safety of the medication use process.

  16. Transport effects with hot electrons in laser fusion. Final report, October 1, 1981-February 28, 1983

    International Nuclear Information System (INIS)

    Shkarofsky, I.P.

    1983-02-01

    Two explanations are offered which can account for heat inhibition found in laser-fusion experiments. The first explanation requires an anisotorpic electron velocity distribution with a higher temperature parallel to the surface than into the surface. This provides axial heat inhibition. Lateral heat inhibition is associated with azimuthal magnetic fields. The second explanation requires the presence of both hot suprathermal and thermal electrons. The hot electrons can cause the flux limiter to decrease substantially below the free-streaming limit in an intermediate range of collisionality. Conditions for this situation occur in the coronal region. We compare a Maxwellian distribution to an exp(-v 5 /v 5 /sub c/) variation for the cold electrons and find that the flux limiter decreases more for the latter case. The effects of collisions between cold and hot electrons is also looked into. The Cartesian tensor approach is used in the above investigations with various forms for the zeroth order electron velocity distribution function

  17. Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery Program

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, M.

    2006-10-31

    technical targets for systems, subsystems, and component research and development activities; (2) Develop and validate individual subsystems and components, including electric motors, emission control devices, battery systems, power electronics, accessories, and devices to reduce parasitic losses; and (3) Determine how well the components and subsystems work together in a vehicle environment or as a complete propulsion system and whether the efficiency and performance targets at the vehicle level have been achieved. The research performed under the Vehicle Systems subprogram will help remove technical and cost barriers to enable the development of technology for use in such advanced vehicles as hybrid and fuel-cell-powered automobiles that meet the goals of the FreedomCAR Program. A key element in making hybrid electric vehicles practical is providing an affordable electric traction drive system. This will require attaining weight, volume, and cost targets for the power electronics and electrical machines subsystems of the traction drive system. Areas of development include these: (1) Novel traction motor designs that result in increased power density and lower cost; (2) Inverter technologies involving new topologies to achieve higher efficiency and the ability to accommodate higher-temperature environments; (3) Converter concepts that employ means of reducing the component count and integrating functionality to decrease size, weight, and cost; (4) More effective thermal control and packaging technologies; and (5) Integrated motor/inverter concepts. The Oak Ridge National Laboratory's (ORNL's) Power Electronics and Electric Machinery Research Center conducts fundamental research, evaluates hardware, and assists in the technical direction of the DOE Office of FreedomCAR and Vehicle Technologies Program, Power Electronics and Electric Machinery Program. In this role, ORNL serves on the FreedomCAR Electrical and Electronics Technical Team, evaluates proposals for DOE

  18. Electron and pion interactions with nuclei. Progress report, August 1, 1983-August 1, 1984

    International Nuclear Information System (INIS)

    McCarthy, J.S.

    1984-01-01

    The experimental program has been based upon the selective use of electron and pion probes to investigate fundamental aspects of nuclear structure. The experiments on electron accelerators span the region from low energy (<100 MeV) high resolution work to the region of electron energy where the fundamental description of the nucleus must be changed. The emphasis in the electron experiments is to understand the basic N-N force, in particular the short range behavior of this force and its effect on nuclear properties. The pion reactions have concentrated on the few body system in an attempt to understand the basic pion-nucleon dynamics

  19. Femtosecond Planar Electron Beam Source for Micron-Scale Dielectric Wake Field Accelerator. Final report

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    2006-01-01

    A new accelerator LACARA is under construction at ATF, Brookhaven National Laboratory. LACARA is to be powered by a 1 TW CO2 laser, and will utilize a 6-T 2-m long solenoidal magnetic field. For a 50 MeV injected electron bunch, LACARA is expected to produce a 100 MeV 1 ps gyrating beam with ∼ 3% energy spread. Beam electrons advance in phase at the laser frequency, executing one cycle each 35 fs. A beam stop with a small off-axis channel will transmit a short beam pulse every optical cycle, thereby producing a train of about 30, 3.5 fs, 1-3 pC microbunches for each laser pulse. One application for this train of microbunches obtained from a LACARA-type device involves focusing a portion of the beam using a magnetic quadrupole into a rectangular cross-section having a narrow dimension of a few microns and a height of a few hundred microns. These microbunches may be injected into a planar dielectric-lined waveguide where cumulative buildup of wake fields can lead to an accelerating gradient > 1 GV/m. This proposed vacuum-based wake field structure is mechanically rigid and capable of accurate microfabrication, factors important in staging a large number of accelerator modules. Furthermore, the accelerating gradients it promises are comparable with those for plasma accelerators. A LACARA unit for preparing suitable bunches at 500 MeV is described. Physics issues are discussed including bunch spreading and transport, bunch shaping, aperture radiation, dielectric breakdown, and bunch stability in the rectangular wake field structure. In appendices to this report, three supporting documents are attached. These include a set of drawings that show the layout of the beam line and optical line for LACARA at ATF-BNL; and two reprints of recent articles published in PRST-AB. The first article describes measurements of the coherent superposition of wake fields that arise from a periodic train of bunches, with supporting analysis. The second article presents theory that

  20. Real-time monitoring of school absenteeism to enhance disease surveillance: a pilot study of a mobile electronic reporting system.

    Science.gov (United States)

    Lawpoolsri, Saranath; Khamsiriwatchara, Amnat; Liulark, Wongwat; Taweeseneepitch, Komchaluch; Sangvichean, Aumnuyphan; Thongprarong, Wiraporn; Kaewkungwal, Jaranit; Singhasivanon, Pratap

    2014-05-12

    School absenteeism is a common source of data used in syndromic surveillance, which can eventually be used for early outbreak detection. However, the absenteeism reporting system in most schools, especially in developing countries, relies on a paper-based method that limits its use for disease surveillance or outbreak detection. The objective of this study was to develop an electronic real-time reporting system on school absenteeism for syndromic surveillance. An electronic (Web-based) school absenteeism reporting system was developed to embed it within the normal routine process of absenteeism reporting. This electronic system allowed teachers to update students' attendance status via mobile tablets. The data from all classes and schools were then automatically sent to a centralized database for further analysis and presentation, and for monitoring temporal and spatial patterns of absent students. In addition, the system also had a disease investigation module, which provided a link between absenteeism data from schools and local health centers, to investigate causes of fever among sick students. The electronic school absenteeism reporting system was implemented in 7 primary schools in Bangkok, Thailand, with total participation of approximately 5000 students. During May-October 2012 (first semester), the percentage of absentees varied between 1% and 10%. The peak of school absenteeism (sick leave) was observed between July and September 2012, which coincided with the peak of dengue cases in children aged 6-12 years being reported to the disease surveillance system. The timeliness of a reporting system is a critical function in any surveillance system. Web-based application and mobile technology can potentially enhance the use of school absenteeism data for syndromic surveillance and outbreak detection. This study presents the factors that determine the implementation success of this reporting system.

  1. Exploring the use of tablet computer-based electronic data capture system to assess patient reported measures among patients with chronic kidney disease: a pilot study.

    Science.gov (United States)

    Wong, Dorothy; Cao, Shen; Ford, Heather; Richardson, Candice; Belenko, Dmitri; Tang, Evan; Ugenti, Luca; Warsmann, Eleanor; Sissons, Amanda; Kulandaivelu, Yalinie; Edwards, Nathaniel; Novak, Marta; Li, Madeline; Mucsi, Istvan

    2017-12-06

    Collecting patient reported outcome measures (PROMs) via computer-based electronic data capture system may improve feasibility and facilitate implementation in clinical care. We report our initial experience about the acceptability of touch-screen tablet computer-based, self-administered questionnaires among patients with chronic kidney disease (CKD), including stage 5 CKD treated with renal replacement therapies (RRT) (either dialysis or transplant). We enrolled a convenience sample of patients with stage 4 and 5 CKD (including patients on dialysis or after kidney transplant) in a single-centre, cross-sectional pilot study. Participants completed validated questionnaires programmed on an electronic data capture system (DADOS, Techna Inc., Toronto) on tablet computers. The primary objective was to evaluate the acceptability and feasibility of using tablet-based electronic data capture in patients with CKD. Descriptive statistics, Fischer's exact test and multivariable logistic regression models were used for data analysis. One hundred and twenty one patients (55% male, mean age (± SD) of 58 (±14) years, 49% Caucasian) participated in the study. Ninety-two percent of the respondents indicated that the computer tablet was acceptable and 79% of the participants required no or minimal help for completing the questionnaires. Acceptance of tablets was lower among patients 70 years or older (75% vs. 95%; p = 0.011) and with little previous computer experience (81% vs. 96%; p = 0.05). Furthermore, a greater level of assistance was more frequently required by patients who were older (45% vs. 15%; p = 0.009), had lower level of education (33% vs. 14%; p = 0.027), low health literacy (79% vs. 12%; p = 0.027), and little previous experience with computers (52% vs. 10%; p = 0.027). Tablet computer-based electronic data capture to administer PROMs was acceptable and feasible for most respondents and could therefore be used to systematically assess PROMs

  2. 15 CFR 711.8 - How to request authorization from BIS to make electronic submissions of declarations or reports.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false How to request authorization from BIS to make electronic submissions of declarations or reports. 711.8 Section 711.8 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY...

  3. Electronic structure and geometries of small compound metal clusters: Progress report, August 1, 1987-July 31, 1988

    International Nuclear Information System (INIS)

    Jena, P.; Rao, B.K.; Khanna, S.N.

    1988-04-01

    Our research during this reporting period has focused on studying electronic structure and properties of both gas-phase clusters and clusters as models of crystals and defects. We have also concentrated on developing new theoretical techniques that can allow us to study large clusters in a computationally effective manner. Following is a summary of results

  4. Electronic structure and geometries of small compound metal clusters: Progress report, August 1, 1988--July 31, 1989

    International Nuclear Information System (INIS)

    Jena, P.; Rao, B.K.; Khanna, S.N.

    1989-04-01

    Our research during this reporting period has focused on the following two aspects of cluster research. Electronic structure and stability of charged clusters and studies of evolution of magnetic properties with increasing cluster size. Following is a summary of our results

  5. A case report of percutaneous endoscopic gastrostomy left-side gastropexy to resolve a recurrent gastric dilatation in a dog previously treated with right-side gastropexy for gastric dilatation volvulus.

    Science.gov (United States)

    Spinella, Giuseppe; Cinti, Filippo; Pietra, Marco; Capitani, Ombretta; Valentini, Simona

    2014-12-01

    A 6-year-old, large-breed, female dog was evaluated for gastric dilatation (GD). The dog was affected by GD volvulus, which had been surgically treated with gastric derotation and right incisional gastropexy. Recurrence of GD appeared 36 hours after surgery. The dilatation was immediately treated with an orogastric probe but still recurred 4 times. Therefore, a left-side gastropexy by percutaneous endoscopic gastrostomy (PEG) was performed to prevent intermittent GD. After PEG tube placement, the patient recovered rapidly without side effects. Several techniques of gastropexy have been described as a prophylactic method for gastric dilatation volvulus, but to the authors' knowledge, this is the first report of left-sided PEG gastropexy performed in a case of canine GD recurrence after an incisional right gastropexy. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. 1979 CECAM workshop on transport of fast electrons in laser fusion plasmas. Progress report

    International Nuclear Information System (INIS)

    Mason, R.J.

    1979-01-01

    Attention is given to three problem areas in laser-driven electron transport: (1) ion-acoustic turbulence as a source of inhibition, (2) the effects of anti E times anti j heating of the thermals, and (3) the possibility of thermal inhibition by thermal electron runaway or trapping

  7. Electron beam fusion (a bibliography with abstracts). Report for 1964-Aug 77

    International Nuclear Information System (INIS)

    Grooms, D.W.

    1977-10-01

    The bibliography cites research on using electron beams to initiate fusion as an alternative to laser fusion. Theoretical and experimental research concerned with the generation and dynamics of relativistic electron beams and their interaction with high atomic number materials is included

  8. Underestimation of Severity of Previous Whiplash Injuries

    Science.gov (United States)

    Naqui, SZH; Lovell, SJ; Lovell, ME

    2008-01-01

    INTRODUCTION We noted a report that more significant symptoms may be expressed after second whiplash injuries by a suggested cumulative effect, including degeneration. We wondered if patients were underestimating the severity of their earlier injury. PATIENTS AND METHODS We studied recent medicolegal reports, to assess subjects with a second whiplash injury. They had been asked whether their earlier injury was worse, the same or lesser in severity. RESULTS From the study cohort, 101 patients (87%) felt that they had fully recovered from their first injury and 15 (13%) had not. Seventy-six subjects considered their first injury of lesser severity, 24 worse and 16 the same. Of the 24 that felt the violence of their first accident was worse, only 8 had worse symptoms, and 16 felt their symptoms were mainly the same or less than their symptoms from their second injury. Statistical analysis of the data revealed that the proportion of those claiming a difference who said the previous injury was lesser was 76% (95% CI 66–84%). The observed proportion with a lesser injury was considerably higher than the 50% anticipated. CONCLUSIONS We feel that subjects may underestimate the severity of an earlier injury and associated symptoms. Reasons for this may include secondary gain rather than any proposed cumulative effect. PMID:18201501

  9. Analytical electron microscopy characterization of uranium-contaminated soils from the Fernald Site, FY1993 report

    International Nuclear Information System (INIS)

    Buck, E.C.; Cunnane, J.C.; Brown, N.R.; Dietz, N.L.

    1994-10-01

    A combination of optical microscopy, scanning electron microscopy with backscattered electron detection (SEM/BSE), and analytical electron microscopy (AEM) is being used to determine the nature of uranium in soils from the Fernald Environmental Management Project. The information gained from these studies is being used to develop and test remediation technologies. Investigations using SEM have shown that uranium is contained within particles that are typically 1 to 100 μm in diameter. Further analysis with AEM has shown that these uranium-rich regions are made up of discrete uranium-bearing phases. The distribution of these uranium phases was found to be inhomogeneous at the microscopic level

  10. X-ray, neutron, and electron scattering. Report of a materials sciences workshop

    International Nuclear Information System (INIS)

    1977-08-01

    The ERDA Workshop on X-ray, Neutron, and Electron Scattering to assess needs and establish priorities for energy-related basic research on materials. The general goals of the Workshop were: (1) to review various energy technologies where x-ray, neutron, and electron scattering techniques might make significant contributions, (2) to identify present and future materials problems in the energy technologies and translate these problems into requirements for basic research by x-ray, neutron, and electron scattering techniques, (3) to recommend research areas utilizing these three scattering techniques that should be supported by the DPR Materials Sciences Program, and (4) to assign priorities to these research areas

  11. An internal report: Electron Spectroscopy of the Oxidation and Aging of U and Pu

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-04-27

    Uranium and Plutonium are highly reactive elements that undergo not only chemical reactions but also nuclear reactions. This can lead to possibly significant materials degradation, a matter of potentially great concern. Here, the issue of the electronic structure changes that occur with oxidation and radiological aging will be addressed, in a fairly empirical manner. In essence, the sensitivity of various electron spectroscopic techniques to oxidation and aging will be surveyed and discussed, including the apparent limitations. It will be found that 5d and 4d X-ray absorption and electron energy loss are essentially blind to the changes corresponding to oxidation and aging in U and Pu.

  12. 30 CFR 210.104 - Must I submit these production reports electronically?

    Science.gov (United States)

    2010-07-01

    ... MINERALS REVENUE MANAGEMENT FORMS AND REPORTS Production Reports-Oil and Gas § 210.104 Must I submit these... Production Reporter Handbook for the most current reporting options, instructions, and security measures. The... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Must I submit these production reports...

  13. Quality of life with palbociclib plus fulvestrant in previously treated hormone receptor-positive, HER2-negative metastatic breast cancer: patient-reported outcomes from the PALOMA-3 trial.

    Science.gov (United States)

    Harbeck, N; Iyer, S; Turner, N; Cristofanilli, M; Ro, J; André, F; Loi, S; Verma, S; Iwata, H; Bhattacharyya, H; Puyana Theall, K; Bartlett, C H; Loibl, S

    2016-06-01

    In the PALOMA-3 study, palbociclib plus fulvestrant demonstrated improved progression-free survival compared with fulvestrant plus placebo in hormone receptor-positive, HER2- endocrine-resistant metastatic breast cancer (MBC). This analysis compared patient-reported outcomes (PROs) between the two treatment groups. Patients were randomized 2 : 1 to receive palbociclib 125 mg/day orally for 3 weeks followed by 1 week off (n = 347) plus fulvestrant (500 mg i.m. per standard of care) or placebo plus fulvestrant (n = 174). PROs were assessed on day 1 of cycles 1-4 and of every other subsequent cycle starting with cycle 6 using the EORTC QLQ-C30 and its breast cancer module, QLQ-BR23. High scores (range 0-100) could indicate better functioning/quality of life (QoL) or worse symptom severity. Repeated-measures mixed-effect analyses were carried out to compare on-treatment overall scores and changes from baseline between treatment groups while controlling for baseline. Between-group comparisons of time to deterioration in global QoL and pain were made using an unstratified log-rank test and Cox proportional hazards model. Questionnaire completion rates were high at baseline and during treatment (from baseline to cycle 14, ≥95.8% in each group completed ≥1 question on the EORTC QLQ-C30). On treatment, estimated overall global QoL scores significantly favored the palbociclib plus fulvestrant group [66.1, 95% confidence interval (CI) 64.5-67.7 versus 63.0, 95% CI 60.6-65.3; P = 0.0313]. Significantly greater improvement from baseline in pain was also observed in this group (-3.3, 95% CI -5.1 to -1.5 versus 2.0, 95% CI -0.6 to 4.6; P = 0.0011). No significant differences were observed for other QLQ-BR23 functioning domains, breast or arm symptoms. Treatment with palbociclib plus fulvestrant significantly delayed deterioration in global QoL (P < 0.025) and pain (P < 0.001) compared with fulvestrant alone. Palbociclib plus fulvestrant allowed patients to maintain good Qo

  14. Electron spin resonance studies of radiation effects. Final report, 1964-1979 (including annual progress reports for 1978 and 1979)

    International Nuclear Information System (INIS)

    Rogers, M.T.

    1979-07-01

    The discovery of new free radicals, largely in irradiated single crystals of nonmetallic solids, and the determination of the molecular and electronic structures of these paramagnetic species by electron spin resonance (ESR) spectroscopy, have been carried out using a wide variety of organic and inorganic materials. The mechanisms of production of radicals in solids, their motions, and their reactions have been investigated and some applicable general principles deduced. Emphasis has been on aliphatic free radicals from irradiated carboxylic acids and amides and their halogen-substituted derivatives, organometallic radicals and substituted cyclic hydrocarbon radicals; inorganic radicals studied include V centers, hypervalent radicals and electron adducts. Extensive investigations of paramagnetic transition metal complexes, particularly cyanides and fluorides, have been made. In all cases quantum mechanical calculations have been employed as far as possible in interpreting the data. An improved method for analyzing experimental ESR spectra of single crystals has been developed and a number of crystal structures have been determined to supplement the ESR studies. Applications of nuclear quadrupole resonance spectroscopy to the study of structure and bonding in inorganic solids have been made and a method for using nuclear magnetic relaxation data for estimating quadrupole coupling constants in liquids has been developed

  15. Status report on the development of a tubular electron beam ion source

    International Nuclear Information System (INIS)

    Donets, E.D.; Donets, E.E.; Becker, R.; Liljeby, L.; Rensfelt, K.-G.; Beebe, E.N.; Pikin, A.I.

    2004-01-01

    The theoretical estimations and numerical simulations of tubular electron beams in both beam and reflex mode of source operation as well as the off-axis ion extraction from a tubular electron beam ion source (TEBIS) are presented. Numerical simulations have been done with the use of the IGUN and OPERA-3D codes. Numerical simulations with IGUN code show that the effective electron current can reach more than 100 A with a beam current density of about 300-400 A/cm 2 and the electron energy in the region of several KeV with a corresponding increase of the ion output. Off-axis ion extraction from the TEBIS, being the nonaxially symmetric problem, was simulated with OPERA-3D (SCALA) code. The conceptual design and main parameters of new tubular sources which are under consideration at JINR, MSL, and BNL are based on these simulations

  16. Surface and interface electronic structure: Third year progress report, December 1, 1988--November 30, 1989

    International Nuclear Information System (INIS)

    Kevan, S.D.

    1989-01-01

    This paper discusses the following topics: linewidths of surface states and resonances; surface bonds and fermi surface of Pd(001); state-resonance transition of Ta(011); and electronic structure of W(010)-2H. 5 figs

  17. Electron transfer reactions in microporous solids. Progress report, September 1990--January 1993

    Energy Technology Data Exchange (ETDEWEB)

    Mallouk, T.E.

    1993-01-01

    Basic thrust the research program involves use of microporous solids (zeolites, clays, layered and tunnel structure oxide semiconductors) as organizing media for artificial photosynthetic systems. Purpose of the microporous solid is twofold. First, it induces spatial organization of photoactive and electroactive components (sensitizers, semiconductor particles, electron relays, and catalysts) at the solid-solution interface, enhancing the quantum efficiency of charge separation and separating physically the ultimate electron donor and acceptor in the electron transport chain. Second, since the microcrystalline solid admits only molecules of a certain charge and size, it is possible to achieve permanent charge separation by sieving chemical photoproducts (e.g., H{sub 2} and I{sub 3}{sup {minus}}, or H{sub 2} and O{sub 2)} from each other. Spectroscopic and electrochemical methods are used to study the kinetics of electron transfer reactions in these hybrid molecular/solid state assemblies.

  18. [Physical properties of f electron systems]: Progress report, February 1987-January 1988

    International Nuclear Information System (INIS)

    Riseborough, P.S.

    1988-01-01

    This paper discusses the progress in research on f electron systems. The major properties discussed in this paper are: magnetic properties, transport properties, heavy fermion superconductivity, and photo-emission spectroscopy

  19. Summary report : working group 5 on 'electron beam-driven plasma and structure based acceleration concepts'

    International Nuclear Information System (INIS)

    Conde, M. E.; Katsouleas, T.

    2000-01-01

    The talks presented and the work performed on electron beam-driven accelerators in plasmas and structures are summarized. Highlights of the working group include new experimental results from the E-157 Plasma Wakefield Experiment, the E-150 Plasma Lens Experiment and the Argonne Dielectric Structure Wakefield experiments. The presentations inspired discussion and analysis of three working topics: electron hose instability, ion channel lasers and the plasma afterburner

  20. A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-04

    In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

  1. Electronic and magnetic interactions in high temperature superconducting and high coercivity materials. Final performance report

    International Nuclear Information System (INIS)

    Cooper, B.R.

    1997-01-01

    The issue addressed in the research was how to understand what controls the competition between two types of phase transition (ordering) which may be present in a hybridizing correlated-electron system containing two transition-shell atomic species; and how the variation of behavior observed can be used to understand the mechanisms giving the observed ordered state. This is significant for understanding mechanisms of high-temperature superconductivity and other states of highly correlated electron systems. Thus the research pertains to magnetic effects as related to interactions giving high temperature superconductivity; where the working hypothesis is that the essential feature governing the magnetic and superconducting behavior of copper-oxide-type systems is a cooperative valence fluctuation mechanism involving the copper ions, as mediated through hybridization effects dominated by the oxygen p electrons. (Substitution of praseodymium at the rare earth sites in the 1·2·3 material provides an interesting illustration of this mechanism since experimentally such substitution strongly suppresses and destroys the superconductivity; and, at 100% Pr, gives Pr f-electron magnetic ordering at a temperature above 16K). The research was theoretical and computational and involved use of techniques aimed at correlated-electron systems that can be described within the confines of model hamiltonians such as the Anderson lattice hamiltonian. Specific techniques used included slave boson methodology used to treat modification of electronic structure and the Mori projection operator (memory function) method used to treat magnetic response (dynamic susceptibility)

  2. Understand electronics

    CERN Document Server

    Bishop, Owen

    2013-01-01

    Understand Electronics provides a readable introduction to the exciting world of electronics for the student or enthusiast with little previous knowledge. The subject is treated with the minimum of mathematics and the book is extensively illustrated.This is an essential guide for the newcomer to electronics, and replaces the author's best-selling Beginner's Guide to Electronics.The step-by-step approach makes this book ideal for introductory courses such as the Intermediate GNVQ.

  3. Excitation and ionization of ions by electron impact. Technical progress report, September 1, 1976--May 31, 1977

    International Nuclear Information System (INIS)

    Feeney, R.K.; Baggett, D.W.; Hughes, D.W.; Rivers, G.W.; Sayle, W.E.

    1977-01-01

    This effort is devoted to experimental measurements of electron impact excitation and ionization cross sections of ions. The cross sections of interest are those of importance in the diagnostics of CTR plasmas. Current tasks include: the completion of absolute measurements of the electron impact double ionization cross sections for Na + , K + , Rb + , Cs + , and Tl + ions; the development of a laboratory-size ion source of multiply-charged ions to be used in the measurement of electron impact excitation and ionization cross sections; and the completion of absolute measurements of the electron impact excitation of Li + ions. Preliminary measurements of the electron impact double ionization cross sections of Na + , K + , Rb + , Cs + , and Tl + ions were completed. Measurements were made over the range of electron energies from the respective threshold values to approximately 1000 eV. Peak cross sections were found to vary from 7.2 x 10 -19 cm 2 for Na + to 3.5 x 10 -17 cm 2 for Cs + . The data were obtained with a crossed beam apparatus operating with modulated beams. A PIG-type source of multiply charged ions is undergoing final development. The source is of laboratory size and is compatible with existing collision apparatus. The previous problem with inadequate magnetic field has been solved. Spectroscopic techniques verified the production of ions of charge state C 4+ when CO 2 was used as the source gas. Some difficulty has been encountered in extracting adequate ion currents. Also under investigation is the optimum technique for the production of metal ions with the PIG-type ion source. A list of publications is included

  4. Electron Cyclotron Resonances in Electron Cloud Dynamics

    International Nuclear Information System (INIS)

    Celata, Christine; Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-01-01

    We report a previously unknown resonance for electron cloud dynamics. The 2D simulation code 'POSINST' was used to study the electron cloud buildup at different z positions in the International Linear Collider positron damping ring wiggler. An electron equilibrium density enhancement of up to a factor of 3 was found at magnetic field values for which the bunch frequency is an integral multiple of the electron cyclotron frequency. At low magnetic fields the effects of the resonance are prominent, but when B exceeds ∼(2 pi mec/(elb)), with lb = bunch length, effects of the resonance disappear. Thus short bunches and low B fields are required for observing the effect. The reason for the B field dependence, an explanation of the dynamics, and the results of the 2D simulations and of a single-particle tracking code used to elucidate details of the dynamics are discussed

  5. Few electron transitions in atomic collisions. Final report, September 1, 1992--December 31, 1995

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.

    1997-04-01

    During the past three years we have evaluated probabilities and cross sections for few and multiple electron transitions in atomic collisions. Our studies included interactions of atoms and molecules with incident protons, bare ions, electrons, positrons, anti-protons, ions carrying electrons and photons. We also: studied the inter-relation between collisions with charged particles and collisions involving various processes with photons. This work has complemented various studies of collisions of atoms with charged particles and with photons as well as more general efforts to understand the nature of multi-electron systems. Our aim has been to begin with relatively simple two electron systems and to focus on fast processes in which there is too little time for complicated processes to occur. We have used a variety of computational techniques, but we emphasize those appropriate for fast collisions in which we hope to obtain insight into the physical nature of the process itself. We generally considered systems in which experimental data was available.

  6. Retrograde amnesia produced by electron beam exposure: casual parameters and duration of memory loss. Final report for November 84

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, T.G.; Hardy, K.A.

    1985-01-01

    The production of retrograde amnesia (RA) upon electron-beam exposure was investigated. RA production was evaluated using a single-trial avoidance task for 10, 1, and 0.1 microsecond pulsed exposures. The dose-response curve obtained at each pulse duration showed significant RA production. The most effective dose range was 0.1-10 rad at a dose rate of 1,000,000 rad/sec. By employing a 10 rad (1,000,000 rad/s) pulse, a memory loss of the events occurring in the previous 4 sec was demonstrated. The conclusion was that the RA effect might be due to sensory system activation which provided a novel stimulus that masked previous stimuli.

  7. Low Voltage Electron Beam Processing Final Report CRADA No. TC-645-93-A

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wakalopulos, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-16

    This CRADA project was established to develop a small, inexpensive sealed-tube electron beam processing system having immediate applications in industrial, high speed manufacturing processes, and in the Department of Energy (DOE) waste treatment/cleanup operations. The technical work involved the development and demonstration of a compact, sealed, 50-75 kilovolt (kV) EB generator prototype, including controls and power supply. The specific goals of this project were to develop a low cost vacuum tube capable of shooting an electron beam several inches into the air, and to demonstrate that wide area materials processing is feasible by stacking the tubes to produce continuous beams. During the project, we successfully demonstrated the producibility of a low cost electron beam system and several material processing operations of interest to US industry, DOE and, since September 11, 2001, the Homeland Security.

  8. Electronic relaxation processes in polyatomic molecules. Progress report, October 1, 1975--September 30, 1976

    International Nuclear Information System (INIS)

    Lim, E.C.

    1976-09-01

    Excitation energy dependence of radiationless decay rate under collision-free conditions was utilized as a probe of intramolecular vibrational relaxation in tetracene and pentacene. The results give evidence of vibrational relaxation which competes with electronic relaxation. The substitution dependence of T 1 (nπ*) → S 0 radiationless transition in monocyclic diazines and the temperature dependence of S 1 non-radiative decay rate in alcoholic solutions of polycyclic monoazines indicate that the vibronic interaction between the lowest energy nπ* and ππ* states leads to a rapid radiationless deactivation of the lower of the two electronic states. Finally, a photon-counting spectrofluorometer of very high sensitivity was constructed, and it was used to record T 2 → T 1 fluorescence in bromoanthracenes and S 2 → S 1 fluorescence in azulene. These spectra represent the first bona-fide, or the most convincing, observation of fluorescence between excited electronic states

  9. EBIT (Electron Beam Ion Trap), N-Division Experimental Physics. Annual report, 1994

    International Nuclear Information System (INIS)

    Schneider, D.

    1995-10-01

    The experimental groups in the Electron Beam Ion Trap (EBIT) program continue to perform front-line research with trapped and extracted highly charged ions (HCI) in the areas of ion/surface interactions, atomic spectroscopy, electron-ion interaction and structure measurements, highly charged ion confinement, and EBIT development studies. The ion surface/interaction studies which were initiated five years ago have reached a stage where they an carry out routine investigations, as well as produce breakthrough results towards the development of novel nanotechnology. At EBIT and SuperEBIT studies of the x-ray emission from trapped ions continue to produce significant atomic structure data with high precision for few electron systems of high-Z ions. Furthermore, diagnostics development for magnetic and laser fusion, supporting research for the x-ray laser and weapons programs, and laboratory astrophysics experiments in support of NASA's astrophysics program are a continuing effort. The two-electron contributions to the binding energy of helium like ions were measured for the first time. The results are significant because their precision is an order of magnitude better than those of competing measurements at accelerators, and the novel technique isolates the energy corrections that are the most interesting. The RETRAP project which was initiated three years ago has reached a stage where trapping, confining and electronic cooling of HCI ions up to Th 80+ can be performed routinely. Measurements of the rates and cross sections for electron transfer from H 2 performed to determine the lifetime of HCI up to Xe q+ and Th q+ (35 ≤ q ≤ 80) have been studied at mean energies estimated to be ∼ 5 q eV. This combination of heavy ions with very high charges and very low energies is rare in nature, but may be encountered in planned fusion energy demonstration devices, in highly charged ion sources, or in certain astrophysical events

  10. EBIT (Electron Beam Ion Trap), N-Division Experimental Physics. Annual report, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D. [ed.

    1995-10-01

    The experimental groups in the Electron Beam Ion Trap (EBIT) program continue to perform front-line research with trapped and extracted highly charged ions (HCI) in the areas of ion/surface interactions, atomic spectroscopy, electron-ion interaction and structure measurements, highly charged ion confinement, and EBIT development studies. The ion surface/interaction studies which were initiated five years ago have reached a stage where they an carry out routine investigations, as well as produce breakthrough results towards the development of novel nanotechnology. At EBIT and SuperEBIT studies of the x-ray emission from trapped ions continue to produce significant atomic structure data with high precision for few electron systems of high-Z ions. Furthermore, diagnostics development for magnetic and laser fusion, supporting research for the x-ray laser and weapons programs, and laboratory astrophysics experiments in support of NASA`s astrophysics program are a continuing effort. The two-electron contributions to the binding energy of helium like ions were measured for the first time. The results are significant because their precision is an order of magnitude better than those of competing measurements at accelerators, and the novel technique isolates the energy corrections that are the most interesting. The RETRAP project which was initiated three years ago has reached a stage where trapping, confining and electronic cooling of HCI ions up to Th{sup 80+} can be performed routinely. Measurements of the rates and cross sections for electron transfer from H{sub 2} performed to determine the lifetime of HCI up to Xe{sup q+} and Th{sup q+} (35 {le} q {le} 80) have been studied at mean energies estimated to be {approximately} 5 q eV. This combination of heavy ions with very high charges and very low energies is rare in nature, but may be encountered in planned fusion energy demonstration devices, in highly charged ion sources, or in certain astrophysical events.

  11. FY2011 Advanced Power Electronics and Electric Motors Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Susan A. [Office of Energy Efficiency and Renewable Energy (EERE), Washington, DC (United States)

    2012-01-31

    The Advanced Power Electronics and Electric Motors (APEEM) program within the DOE Vehicle Technologies Program (VTP) provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE), electric motor (EM), thermal management, and traction drive system technologies that will leapfrog current on-the-road technologies. The research and development (R&D) is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow’s automobiles will function as a unified system to improve fuel efficiency.

  12. FY2010 Annual Progress Report for Advanced Power Electronics and Electric Motors

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Susan A. [Office of Energy Efficiency and Renewable Energy (EERE), Washington, DC (United States)

    2011-01-01

    The Advanced Power Electronics and Electric Machines (APEEM) subprogram within the Vehicle Technologies Program provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE) and electric motor technologies that will leapfrog current on-the-road technologies. The research and development (R&D) is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow’s automobiles will function as a unified system to improve fuel efficiency.

  13. Feasibility of using a handheld electronic device for the collection of patient reported outcomes data from children

    OpenAIRE

    Vinney, Lisa A.; Grade, John; Connor, Nadine P.

    2011-01-01

    The manner in which a communication disorder affects health-related quality of life (QOL) in children is not known. Unfortunately, collection of quality of life data via traditional paper measures is labor intensive and has several other limitations, which hinder the investigation of pediatric quality of life in children. Currently, there is not sufficient research regarding the use of electronic devices to collect pediatric patient reported outcomes in order to address such limitations. Thus...

  14. Seizure is a rare presentation for acute hemolysis due to G6PD deficiency. We report a previously healthy boy who presented initially with seizure and cyanosis and subsequently acute hemolysis, due to glucose-6-phosphate dehydrogenase deficiency (G6PD) an

    OpenAIRE

    Afshin FAYYAZI; Ali KHAJEH; Hosein ESFAHANI

    2012-01-01

    Seizure is a rare presentation for acute hemolysis due to G6PD deficiency. We report a previously healthy boy who presented initially with seizure and cyanosis and subsequently acute hemolysis, due to glucose-6-phosphate dehydrogenase deficiency (G6PD) and probably secondary methemoglobinemia, following the ingestion of fava beans.

  15. Analytical electron microscopy characterization of Fernald soils. Annual report, October 1993--September 1994

    International Nuclear Information System (INIS)

    Buck, E.C.; Brown, N.R.; Dietz, N.L.

    1995-03-01

    A combination of backscattered electron imaging and analytical electron microscopy (AEM) with electron diffraction have been used to determine the physical and chemical properties of uranium contamination in soils from the Fernald Environmental Management Project in Ohio. The information gained from these studies has been used in the development and testing of remediation technologies. Most chemical washing techniques have been reasonably effective with uranyl [U(VI)] phases, but U(IV) phases have proven difficult to remove from the soils. Carbonate leaching in an oxygen environment (heap leaching) has removed some of the U(IV) phases, and it appears to be the most effective technique developed in the program. The uranium metaphosphate, which was found exclusively at an incinerator site, has not been removed by any of the chemical methods. We suggest that a physical extraction procedure (either a magnetic separation or aqueous biphasic process) be used to remove this phase. Analytical electron microscopy has also been used to determine the effect of the chemical agents on the uranium phases. It has also been used to examine soils from the Portsmouth site in Ohio. The contamination there took the form of uranium oxide and uranium calcium oxide phases. Technology transfer efforts over FY 1994 have led to industry-sponsored projects involving soil characterization

  16. Test report: Electron-proton spectrometer qualification test unit, qualification test

    Science.gov (United States)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  17. Annual report of the group for maintenance of electronic equipment; Godisnji izvestaj elektronske grupe

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, B [Reaktor RA, Odelenje odrzavanja, Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1965-12-15

    Maintenance and repair of the RA reactor control and safety systems were uniformly distributed during the whole year and were done according to the annual plan. A series of repairs of he electronic equipment as well as exchange of electronic components and elec tonic tubes. The testing and calibration of control and protection circuits were done regularly according to the needs and operation state of the reactor and according to the instructions. Inspections, repairs and reconstructions well as operating characteristics of individual elements as well as complete electronic circuits during 1965 have shown da the systems of control and safety are still in good condition. Somewhat higher number of failures due to aging of electronic tubes is a regular consequence of equipment and instrumentation aging. [Serbo-Croat] Remontni radovi na opremi sistema za upravljanje i sigurnost reaktora RA ravnomerno su rasporedjeni tokom cele godine i obavljaju se prema planu remonta. Izvrsen je citav niz popravki elektronske instrumentacije, kao i zamena komponenti i elektronskih cevi. Sve kontrole ispravnosti i kalibracije lanaca za upravljanje i zastitu reaktora redovno su vrsene prema potrebi i u vezi sa radnim stanjem reaktora prema uputstvu za ove operacije. Pregledi, remonti i popravke kao i radne karakteristike pojedinih elemenata kao i kompletnih instrumentalnih kontrolnih lanaca u toku 1965. godine pokazali su da su sistemi upravljanja i sigurnosne zastite jos u dobrom stanju. Nesto veci broj kvarova usled starenja elektronskih cevi je normalna posledica starenja opreme i instrumentacije.

  18. Duration of memory loss due to electron beam exposure. Final report Jan-May 1983

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, T.G.; Tilton, B.M.

    1983-08-01

    Electron beam exposure has been shown to produce retrograde amnesia (RA). The objective of this study was to determine the duration of memory loss upon electron beam exposure. It is important to know if exposure produces a memory loss of the events which occurred in the preceding 1 sec or memory loss of the preceding minute's events. The task was a single-trial avoidance paradigm. The animal was placed in a small aversive chamber. After a 90-sec adaptation period, a door opened that provided access to a large, dark, preferred chamber. The time required for the animal to enter the preferred chamber was the measure of interest (T). Once inside the preferred chamber, a 1-sec footshock was delivered. Following the footshock by some preset delay (delta T), the animal was exposed to a 10-microsec, 10-rad electron beam (or X-ray). A second trial on the task was run 2 hr postexposure. The second trial consisted of placing the animal in the aversive chamber and monitoring the time (T') required to enter the preferred chamber. If the electron beam exposure interfered with the animal's ability to recall the shock, T' would be greatly reduced as compared with the sham controls. The exposure delay times used were delta T = 1, 3, 5, and 10 sec.

  19. Absolute experimental cross sections for the electron impact ionization of rubidium. Technical summary report

    International Nuclear Information System (INIS)

    Hughes, D.W.; Feeney, R.K.

    1980-01-01

    The absolute cross sections for the double, triple, and quadruple ionization of Rb + ions by electron impact have been measured from below their respective thresholds to approximately 3000 eV. This determination has been accomplished using a crossed beam facility in which monoenergetic beams of ions and electrons are caused to intersect at right angles in a well-defined collision volume. Multiply charged, product ions born as a result of the electron impact are deflected into their respective detectors by cascaded electrostatic analyzers. The multiply charged beam current component is measured by means of a vibrating reed electrometer operating in the rate-of-charge mode. The required singly charged rubidium ions are produced in a thermionic ion source and pass through a series of focusing, collimating and deflecting structures before entering the interaction region. A thermionically generated, rectangular electron beam intercepts the target ions in a spatially designated collision volume. Just prior to entering this interaction region the two beams can be made to pass through a movable slit scanner which determines their spatial profiles. The various charged particle currents, energies and beam current density distributions represent the experimental data from which the desired absolute cross sections have been determined. The results obtained with this technique are compared with available theoretical predictions of the appropriate cross sections

  20. Behavioral-Progress Monitoring Using the Electronic Daily Behavioral Report Card (e-DBRC) System

    Science.gov (United States)

    Burke, Mack D.; Vannest, Kimberly J.

    2008-01-01

    In this article, the authors present an overview of a Web-based electronic system for behavioral-progress monitoring. Behavioral-progress monitoring is necessary to evaluate responsiveness to behavioral interventions, the effects of positive behavioral support, and the attainment of individualized education program goals and objectives. The…

  1. The influence of previous low back trouble, general health, and working conditions on future sick-listing because of low back trouble. A 15-year follow-up study of risk indicators for self-reported sick-listing caused by low back trouble.

    Science.gov (United States)

    Müller, C F; Monrad, T; Biering-Sørensen, F; Darre, E; Deis, A; Kryger, P

    1999-08-01

    A 15-year follow-up study. To find risk indicators for self-reported sick-listing because of low back trouble and to evaluate which variables were the most important indicators of work incapacity resulting from low back trouble during the follow-up period of 15 years. The initial data were obtained from a health survey conducted in a general population from the Municipality of Glostrup, Denmark. The follow-up data included information from the Central Person Register, the Early Retirement Pension Register, and a postal questionnaire regarding self-reported sick-listing because of low back trouble. An epidemiologic study, in which logistic regression analyses were used for evaluation of the data. The model used consisted of the variable in question, age, gender, and previous experience of low back trouble, along with interactions. It was found that 22 of 37 variables were risk indicators for later self-reported sick-listing because of low back trouble during the preceding year or the 7 years before the date of follow-up evaluation. In analyzing the most significant variables simultaneously, it was found that information from the initial investigation about sick-listing in general during the previous 10 years, sciatic pain, use of analgesics for low back trouble, previous sick-listing because of low back trouble, and occupation were the most important risk indicators for self-reported work incapacity resulting from low back trouble during the follow-up period of 15 years. Findings showed that the strongest prognostic indicators of later sick-listing because of low back trouble involve information from the person about previous sick-listing behavior in general and previous experience of low back trouble episodes, especially if these had been accompanied by sciatic pain, use of analgesics, or previous low back trouble sick-listing.

  2. Feasibility of using a handheld electronic device for the collection of patient reported outcomes data from children.

    Science.gov (United States)

    Vinney, Lisa A; Grade, John D; Connor, Nadine P

    2012-01-01

    The manner in which a communication disorder affects health-related quality of life (QOL) in children is not known. Unfortunately, collection of quality of life data via traditional paper measures is labor intensive and has several other limitations, which hinder the investigation of pediatric quality of life in children. Currently, there is not sufficient research regarding the use of electronic devices to collect pediatric patient reported outcomes in order to address such limitations. Thus, we used a cross-over design to compare responses to a pediatric health quality of life instrument (PedsQL 4.0) delivered using a handheld electronic device to those from a traditional paper form. Respondents were children with (n=9) and without (n=10) a speech or voice disorder. For paper versus the electronic format, we examined time to completion, number of incomplete or inaccurate question responses, intra-rater reliability, ease of use, and child and parent preference. There were no significant differences between children's scores, time to complete the measure, or ratings related to ease of answering questions. The percentage of children who made answering errors or omissions with paper and pencil was significantly greater than the percentage of children who made such errors using the device. This preliminary study demonstrated that use of an electronic device to collect QOL or patient-reported outcomes (PRO) data from children is more efficient than and just as feasible, reliable, and acceptable as using paper forms. The development of hardware and software applications for the collection of QOL and/or PRO data in children with speech disorders is likely warranted. The reader will be able to understand: (1) The potential benefits of using electronic data capture via handheld devices for collecting pediatric patient reported outcomes; (2) The Pediatric Quality of Life Inventory 4.0 is a measure of the perception of general health quality that has distinguished between

  3. Collision cross sections for few electron systems. Final report, August 1, 2992--July 31, 1995

    International Nuclear Information System (INIS)

    Reading, J.F.; Ford, A.L.

    1995-01-01

    The purpose of this project was to produce accurate cross sections for collisionally induced reactions from the ground stated and excited states of species of ions and at present in a hot fusion plasma. The collisional constituents may be divided into two categories for the purpose of calculations: Those in which a bare projectile excites a one electron or two electron ion or atom from its ground state, or excited states to higher excited states or ionized states. Those in which the projectile has one or more electrons attached to it and excites a one electron or two electron ion or atom from its ground state, or excited states to higher excited states or ionized states. During the collision the projectile itself may change its state being simultaneously excited or ionized. Cross sections are needed typically over the whole energy range from low velocities where molecular, orbitals begin to form to high velocities where first Born or more sophisticated asymptotic theories can be used. These high energy cross sections are very useful for experimentalists to check the absolute normalization of their cross sections. The theoretical tools used were therefore both analytical and numerical in character. Numerical calculations were restricted to expansions of the wavefunctions in a set of finite hilbert basis states (FHBS). The many body aspects of the problem, i.e. the important presence of the interelectron force, or correlation mandate a careful systematic approach. But this section was tempered in our strategy by the fact that many of the cross sections needed, especially from excited states, have never been calculated or measured at all. Thus any information we can provide is useful even if later work may modify our results

  4. Development of an electronic medical report delivery system to 3G GSM mobile (cellular) phones for a medical imaging department.

    Science.gov (United States)

    Lim, Eugene Y; Lee, Chiang; Cai, Weidong; Feng, Dagan; Fulham, Michael

    2007-01-01

    Medical practice is characterized by a high degree of heterogeneity in collaborative and cooperative patient care. Fast and effective communication between medical practitioners can improve patient care. In medical imaging, the fast delivery of medical reports to referring medical practitioners is a major component of cooperative patient care. Recently, mobile phones have been actively deployed in telemedicine applications. The mobile phone is an ideal medium to achieve faster delivery of reports to the referring medical practitioners. In this study, we developed an electronic medical report delivery system from a medical imaging department to the mobile phones of the referring doctors. The system extracts a text summary of medical report and a screen capture of diagnostic medical image in JPEG format, which are transmitted to 3G GSM mobile phones.

  5. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran's Electronic Health Record (EHR) System.

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-04-01

    Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.

  6. The Research Laboratory of Electronics Progress Report Number 136, 1 January-31 December 1993

    Science.gov (United States)

    1994-06-01

    the previous four years for of gravitational lensing-the distortion of radio the Office of Solar System Exploration of the signals from distant radio...355 Energia Nucleare e Energie Alternative (Italy) 249 Geophysics 325 Energy transfer 133 Geraci, James R. 35, 37 Entin, Ilya 209, 225 Gold, Bernard 317

  7. Interaction of low energy electrons with surface lattice vibrations. Final report

    International Nuclear Information System (INIS)

    Tong, S.Y.

    1984-01-01

    In carrying out the DOE contract, we have succeeded in constructing a new microscopic theory, with multiple scattering, for the inelastic scattering of electrons by surface vibrations. We have applied the theory to detailed studies of angle and energy variations of the inelastic cross-section for two important systems in surface physics: carbon monoxide molecules adsorbed on the (100) surface of a nickel crystal, and hydrogen atoms adsorbed on a reconstructed tungsten (100) surface. These calculations have outlined general trends that we expect to apply to a wide variety of systems. Also, we have discovered a series of new selection rules that apply to off-specular scattering. Particularly interesting are pseudo-selection rules which are not group theoretical in origin, but approximate statements that hold well when the electron scattering amplitude exhibits a slow energy variation. We have found and defined conditions for which these selection rules would hold and break down

  8. Final report: ES11: The 23rd Annual Workshop on Electronic Structure Methods

    Energy Technology Data Exchange (ETDEWEB)

    Rappe, Andrew M. [Univ. of Pennsylvania, Philadelphia, PA (United States). Dept. of Chemistry

    2011-08-31

    ES11: the 23rd Annual Workshop on Electronic Structure Methods was held from June 6-9, 2011 at the University of Pennsylvania. The local organizing committee (see Section II) led by PI Andrew M. Rappe supervised the organization of the conference, before, during, and after the meeting itself. The national organizing committee set the technical program of talks, and provided support and advice in various ways. The conference was well-attended (see Section III). An important feature of this conference was a series of panel discussions (see Section IV) to discuss the field of electronic structure and to set new directions. The technical program was of extraordinarily high quality (see Section V). The host institution, the University of Pennsylvania, provided a supportive environment for this meeting (see Section VI).

  9. FY2013 Advanced Power Electronics and Electric Motors R&D Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Susan A. [Dept. of Energy (DOE), Washington DC (United States). Vehicle Technologies Office

    2014-02-01

    The Advanced Power Electronics and Electric Motors (APEEM) technology area within the DOE Vehicle Technologies Office (VTO) provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE), electric motor, and traction drive system (TDS) technologies that will leapfrog current on-the-road technologies, leading to lower cost and better efficiency in transforming battery energy to useful work. The research and development (R&D) is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow’s automobiles will function as a unified system to improve fuel efficiency through research in more efficient TDSs.

  10. Procedures for Electronic Analysis of Business Reports of 33 Afro-American Transnational Entrepreneurs

    DEFF Research Database (Denmark)

    Decker, Arnim

    The sample was derived from from the ADM 2015 event (American Diaspora Marketplace). The US Federal Government undertakes a yearly business competition with the aim to enhance entrepreneurship in Africa. We conducted a feasibility study to test electronic text mining in the field...... of entrepreneurship research. Text Mining is useful for extracting high-quality information from text by devising patterns and trends. We created 3 types of representations: A) Dendrogram, B) Word cloud of most used words (here one document only), and C) bar chart of words with highest semantic significance (here one...... document only). Tre results show that electronic textmining is a useful tool, however methods for unsupervised text analysis can be difficult to interpret....

  11. NASA-DoD Lead-Free Electronics Project. DRAFT Joint Test Report

    Science.gov (United States)

    Kessel, Kurt

    2011-01-01

    The use of conventional tin-lead (SnPb) in circuit board manufacturing is under ever-increasing political scrutiny due to increasing regulations concerning lead. The "Restriction of Hazardous Substances" (RoHS) directive enacted by the European Union (EU) and a pact between the United States National Electronics Manufacturing Initiative (NEMI), Europe's Soldertec at Tin Technology Ltd. and the Japan Electronics and Information Technology Industries Association (JEITA) are just two examples where worldwide legislative actions and partnerships/agreements are affecting the electronics industry. As a result, many global commercial-grade electronic component suppliers are initiating efforts to transition to lead-free (Pb-free) in order to retain their worldwide market. Pb-free components are likely to find their way into the inventory of aerospace or military assembly processes under current government acquisition reform initiatives. Inventories "contaminated" by Pb-free will result in increased risks associated with the manufacturing, product reliability, and subsequent repair of aerospace and military electronic systems. Although electronics for military and aerospace applications are not included in the RoHS legislation, engineers are beginning to find that the commercial industry's move towards RoHS compliance has affected their supply chain and changed their parts. Most parts suppliers plan to phase out their non-compliant, leaded production and many have already done so. As a result, the ability to find leaded components is getting harder and harder. Some buyers are now attempting to acquire the remaining SnPb inventory, if it's not already obsolete. Original Equipment Manufacturers (OEMs), depots, and support contractors have to be prepared to deal with an electronics supply chain that increasingly provides more and more parts with Pb-free finishes-some labeled no differently than their Pb counterparts-while at the same time providing the traditional Pb parts

  12. Sixty Percent Conceptual Design Report: Enterprise Accountability System for Classified Removable Electronic Media

    Energy Technology Data Exchange (ETDEWEB)

    B. Gardiner; L.Graton; J.Longo; T.Marks, Jr.; B.Martinez; R. Strittmatter; C.Woods; J. Joshua

    2003-05-03

    Classified removable electronic media (CREM) are tracked in several different ways at the Laboratory. To ensure greater security for CREM, we are creating a single, Laboratory-wide system to track CREM. We are researching technology that can be used to electronically tag and detect CREM, designing a database to track the movement of CREM, and planning to test the system at several locations around the Laboratory. We focus on affixing ''smart tags'' to items we want to track and installing gates at pedestrian portals to detect the entry or exit of tagged items. By means of an enterprise database, the system will track the entry and exit of tagged items into and from CREM storage vaults, vault-type rooms, access corridors, or boundaries of secure areas, as well as the identity of the person carrying an item. We are considering several options for tracking items that can give greater security, but at greater expense.

  13. Development of Electronic Medical Record-Based "Rounds Report" Results in Improved Resident Efficiency, More Time for Direct Patient Care and Education, and Less Resident Duty Hour Violations.

    Science.gov (United States)

    Ham, Phillip B; Anderton, Toby; Gallaher, Ryan; Hyrman, Mike; Simmerman, Erika; Ramanathan, Annamalai; Fallaw, David; Holsten, Steven; Howell, Charles Gordon

    2016-09-01

    Surgeons frequently report frustration and loss of efficiency with electronic medical record (EMR) systems. Together, surgery residents and a programmer at Augusta University created a rounds report (RR) summarizing 24 hours of vitals, intake/output, labs, and other values for each inpatient that were previously transcribed by hand. The objective of this study was to evaluate the RR's effect on surgery residents. Surgery residents were queried to assess the RR's impact. Outcome measures were time spent preparing for rounds, direct patient care time, educational activity time, rates of incorrect/incomplete data on rounds, and rate of duty hour violations. Hospital wide, 17,200 RRs were generated in the 1-month study. Twenty-three surgery residents participated. Time spent preparing for rounds decreased per floor patient (15.6 ± 3.0 vs 6.0 ± 1.2, P care unit patient (19.9 ± 2.9 vs 7.5 ± 1.2 P care increased from 45.1 ± 5.6 to 54.0 ± 5.7 per cent (P = 0.0044). Educational activity time increased from 35.2 ± 5.4 to 54.7 ± 7.1 minutes per resident per day (P = 0.0004). Reported duty hour violations decreased 58 per cent (P care at academic medical centers.

  14. Summary Report of Working Group 5: Electron Beam Driven Plasma Accelerators

    International Nuclear Information System (INIS)

    Hogan, Mark J.; Conde, Manoel E.

    2009-01-01

    Electron beam driven plasma accelerators have seen rapid progress over the last decade. Recent efforts have built on this success by constructing a concept for a plasma wakefield accelerator based linear collider. The needs for any future collider to deliver both energy and luminosity have substantial implications for interpreting current experiments and setting priorities for the future. This working group reviewed current experiments and ideas in the context of the demands of a future collider. The many discussions and presentations are summarized here.

  15. Electron acceleration by laser fields in a gas: Technical progress report

    International Nuclear Information System (INIS)

    Fontana, J.R.

    1987-01-01

    Alternative media are considered for inverse Cherenkov interactions, with refractive indices given for several neutral gases. Breakdown considerations are taken into account as well as elastic collisions. Properties of ionized gases are also discussed as they relate to the usefulness of plasmas as accelerator media. The planning for inverse Cherenkov interaction experiments at a CO 2 laser, 50 MeV electron linac test facility is being carried out

  16. Final Report DE-EE0005380: Assessment of Offshore Wind Farm Effects on Sea Surface, Subsurface and Airborne Electronic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Hao [The University of Texas at Austin; Hamilton, Mark F. [The University of Texas at Austin Applied Research Laboratories; Bhalla, Rajan [Science Applications International Corporation; Brown, Walter E. [The University of Texas at Austin Applied Research Laboratories; Hay, Todd A. [The University of Texas at Austin Applied Research Laboratories; Whitelonis, Nicholas J. [The University of Texas at Austin; Yang, Shang-Te [The University of Texas at Austin; Naqvi, Aale R. [The University of Texas at Austin

    2013-09-30

    Offshore wind energy is a valuable resource that can provide a significant boost to the US renewable energy portfolio. A current constraint to the development of offshore wind farms is the potential for interference to be caused by large wind farms on existing electronic and acoustical equipment such as radar and sonar systems for surveillance, navigation and communications. The US Department of Energy funded this study as an objective assessment of possible interference to various types of equipment operating in the marine environment where offshore wind farms could be installed. The objective of this project was to conduct a baseline evaluation of electromagnetic and acoustical challenges to sea surface, subsurface and airborne electronic systems presented by offshore wind farms. To accomplish this goal, the following tasks were carried out: (1) survey electronic systems that can potentially be impacted by large offshore wind farms, and identify impact assessment studies and research and development activities both within and outside the US, (2) engage key stakeholders to identify their possible concerns and operating requirements, (3) conduct first-principle modeling on the interactions of electromagnetic signals with, and the radiation of underwater acoustic signals from, offshore wind farms to evaluate the effect of such interactions on electronic systems, and (4) provide impact assessments, recommend mitigation methods, prioritize future research directions, and disseminate project findings. This report provides a detailed description of the methodologies used to carry out the study, key findings of the study, and a list of recommendations derived based the findings.

  17. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  18. Publication and dissemination of Annual Reports to shareholders in Nigeria and the United Kingdom: The Economics of Social Media and Electronic Communication

    OpenAIRE

    Olagoke Kuye

    2015-01-01

    While the cost of printing and sending out annual reports to shareholders by companies keep increasing and arguments have been made for cheaper and cost-effective ways of carrying out financial disclosure obligations by companies including electronic method, Companies’ Acts maintain that shareholders remain the ultimate decision-maker in the question whether electronic means of publishing annual reports is to be adopted as the primary means of publishing and disseminating annual reports among...

  19. Automatic electromagnetic valve for previous vacuum

    International Nuclear Information System (INIS)

    Granados, C. E.; Martin, F.

    1959-01-01

    A valve which permits the maintenance of an installation vacuum when electric current fails is described. It also lets the air in the previous vacuum bomb to prevent the oil ascending in the vacuum tubes. (Author)

  20. Excitation of rare gases in an electron-beam-controlled discharge: report on preliminary experiments

    International Nuclear Information System (INIS)

    Bingham, F.W.

    1976-05-01

    Data from the preliminary phase of a study of rare-gas-excimer production in an electron-beam-controlled discharge are presented. The results indicate that it is possible to maintain an arc-free discharge in preionized Ar and Xe gas for a period of several microseconds at applied external E/p values up to 5 V/cm/Torr. In these experiments ultraviolet radiation emitted during the discharge signaled the presence of excited rare-gas molecules. Application of the external electric field significantly enhanced the ultraviolet intensity from xenon-gas discharges but produced little enhancement from argon-gas discharges

  1. Micromachined VLSI 3D electronics. Final report for period September 1, 2000 - March 31, 2001

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, C.P.; Steinbeck, J.; Hsueh, K.L.

    2001-03-31

    The phase I program investigated the construction of electronic interconnections through the thickness of a silicon wafer. The novel aspects of the technology are that the length-to-width ratio of the channels is as high as 100:1, so that the minimum amount of real estate is used for contact area. Constructing a large array of these through-wafer interconnections will enable two circuit die to be coupled on opposite sides of a silicon circuit board providing high speed connection between the two.

  2. 76 FR 2677 - Request Facilities To Report Toxics Release Inventory Information Electronically or Complete Fill...

    Science.gov (United States)

    2011-01-14

    ... reflected by the generally increasing percentage of facilities that submit TRI reporting forms... ability to submit valid chemical data files from third party software using eXtensible Markup Language...

  3. Extracting and analyzing ejection fraction values from electronic echocardiography reports in a large health maintenance organization.

    Science.gov (United States)

    Xie, Fagen; Zheng, Chengyi; Yuh-Jer Shen, Albert; Chen, Wansu

    2017-12-01

    The left ventricular ejection fraction value is an important prognostic indicator of cardiovascular outcomes including morbidity and mortality and is often used clinically to indicate severity of heart disease. However, it is usually reported in free-text echocardiography reports. We developed and validated a computerized algorithm to extract ejection fraction values from echocardiography reports and applied the algorithm to a large volume of unstructured echocardiography reports between 1995 and 2011 in a large health maintenance organization. A total of 621,856 echocardiography reports with a description of ejection fraction values or systolic functions were identified, of which 70 percent contained numeric ejection fraction values and the rest (30%) were text descriptions explicitly indicating the systolic left ventricular function. The 12.1 percent (16.0% for male and 8.4% for female) of these extracted ejection fraction values are <45 percent. Validation conducted based on a random sample of 200 reports yielded 95.0 percent sensitivity and 96.9 percent positive predictive value.

  4. Experiments in high voltage electron microscopy. Progress report, October 31, 1976--August 1977

    International Nuclear Information System (INIS)

    Mitchell, T.E.; Hobbs, L.W.; Howitt, D.G.; Barnard, R.; Ro, H.

    1977-07-01

    High voltage electron microscopy (HVEM) is being used to study the effects of irradiation on a variety of materials. The vacancies and interstitials produced by displacement can aggregate to form dislocation loops and voids, annihilate at sinks, or enhance various diffusion processes such as precipitation and recrystallization. Threshold displacement energies, E/sub d/, have been determined for a number of fcc, bcc and hcp metals and for various oxides. In MgO, E/sub d/ is less along (100) than (110); also, E/sub d/ decreases with increasing temperature, possibly due to thermally activated escape of interstitials from recombination volumes or softening of saddle points. The effects of electron irradiation on precipitation in Al--Cu, Al--Si and Ni--Al alloys have been investigated. Precipitation respectively of theta', Si and γ' is enhanced and growth rates are explicable in terms of theories of radiation-enhanced diffusion, with D/sub rad/ approx. 10 -15 cm 2 sec -1 . In oxides, damage gives rise to interstitial dislocation loop nucleation and growth in all cases, perfect [110] loops in MgO faulted basal and prismatic loops in Al 2 O 3 . Quantitative analysis of loop growth rates in MgO gives a migration energy of 3.3 eV for anion vacancies. Other radiation effects include sublimation of MgO and decomposition of MgAl 2 O 4 and Mg 2 SiO 4 into MgO plus other phases

  5. Experiments in high voltage electron microscopy. Progress report, October 31, 1975--August 1976

    International Nuclear Information System (INIS)

    Mitchell, T.E.; Das, G.; Barnard, R.; Ro, D.

    1976-08-01

    High voltage electron microscopy (HVEM) is being used to study the effects of irradiation on a variety of materials. The vacancies and interstitials produced by displacement can agglomerate to form dislocation loops and voids, annihilate at sinks, or enhance various diffusion processes such as precipitation and recrystallization. Threshold displacement energies, E/sub d/, have been determined for a number of fcc, bcc, and hcp metals. Directions for minimum E/sub d/ have been correlated with the crystal structure and the magnitude of E/sub d/ has been related to the sublimation energy. The effects of electron irradiation on precipitation in Al--Cu, Al--Si and Ni--Al alloys have been investigated. Precipitation respectively of theta', Si and γ' is enhanced and growth rates are being related quantitatively to theories of radiation-enhanced diffusion. Results on radiation damage in oxides (quartz, alumina, and magnesia) have also been obtained. Displacement damage gives rise to dislocation loop nucleation and growth in all cases, including multi-layer loops in Al 2 O 3 . In SiO 2 , ionization damage also occurs, which destroys the crystallinity. Threshold displacement and temperature effects have also been investigated

  6. Modification of Color Centers by Electron Bombardment: Final Report CRADA No. TC-0460-93-A

    Energy Technology Data Exchange (ETDEWEB)

    Van Bibber, Karl [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alger, Don M. [Quali-Tech, Inc., Columbia, MO (United States)

    2000-11-30

    The purpose of the project was to: Identify those electron beam irradiation parameters most relevant to process quality and efficiency, to producing and modifying color centers in topaz. Develop and test improved radiation processing techniques, and evaluate their potential applicability to other types of semi-precious gems. Develop an optimized data base for the process and procedures for identifying and characterizing material from new and diverse sources. Transfer new processing technology to the private sector, and, until they are implemented industrially, to perform radiation dosing to partially satisfy existing excess demand. We planned to define the interaction between sample purity level, the physics of irradiation to achieve color cent-er modification on a reproducible basis and demonstration of the resulting process on a commercially viable basis. The primary deliverable was the increased knowledge base in terms of expanded understanding of the systematics of color center modification in materials, and an extensive database of electron beam parameters which would optimize the efficiency and quality of radiation processing of topaz from diverse sources. The radiation processing of these stones constitutes a deliverable to Quali-Tech by LLNL.

  7. Electron and pion interactions with nuclei. Progress report and research plans

    International Nuclear Information System (INIS)

    McCarthy, J.S.

    1982-08-01

    A series of electron scattering experiments is proposed for a quantitative investigation of the structure and dynamics of nuclei. The information developed from the electromagnetic interaction will be used as complement to a series of experiments at LAMPF in which a systematic investigation of the reaction dynamics of pion-nucleus interactions is carried out. Pion induced reactions can supply information on inelastic channels of the nucleon-nucleon interaction which are not as readily available to an electromagnetic probe. Pion absorption experiments designed to measure the off-shell behavior are complemented with a program on pion elastic and inelastic scattering to pursue the on-shell aspect of the π + N interaction. The single (SCE) and double charge exchange (DCE) reactions are unique aspects of π interactions in nuclei. The complementarity of information from different reactions is emphasized in our studies of (e,e'), (p,p'), (π,p) and (p,d) reactions at large momentum transfers (Q greater than or equal to 0.5 GeV/c). Along with the search for the reaction dynamics, the question of new nuclear structure is pursued. We now plan to start a series of experiments that will detect hadrons in the final state along with the scattered electrons. The present success of quantum chromodynamics (QCD) gives increased impetus to pursue experiments that can result in a synthesis of nuclear structure within the framework of the elementary quark; carrying the charge and weak currents within hadrons

  8. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    Science.gov (United States)

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  9. Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery Program

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, M.

    2008-10-15

    The U.S. Department of Energy (DOE) and the U.S. Council for Automotive Research (composed of automakers Ford, General Motors, and Chrysler) announced in January 2002 a new cooperative research effort. Known as FreedomCAR (derived from 'Freedom' and 'Cooperative Automotive Research'), it represents DOE's commitment to developing public/private partnerships to fund high-risk, high-payoff research into advanced automotive technologies. Efficient fuel cell technology, which uses hydrogen to power automobiles without air pollution, is a very promising pathway to achieve the ultimate vision. The new partnership replaces and builds upon the Partnership for a New Generation of Vehicles initiative that ran from 1993 through 2001. The Advanced Power Electronics and Electric Machines (APEEM) subprogram within the Vehicle Technologies Program provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on understanding and improving the way the various new components of tomorrow's automobiles will function as a unified system to improve fuel efficiency. In supporting the development of hybrid propulsion systems, the APEEM effort has enabled the development of technologies that will significantly improve advanced vehicle efficiency, costs, and fuel economy. The APEEM subprogram supports the efforts of the FreedomCAR and Fuel Partnership through a three-phase approach intended to: (1) identify overall propulsion and vehicle-related needs by analyzing programmatic goals and reviewing industry's recommendations and requirements and then develop the appropriate technical targets for systems, subsystems, and component research and development activities; (2) develop and validate individual subsystems and components, including electric motors, and power electronics; and (3) determine how well the components and subsystems work together in a vehicle environment or as a complete propulsion

  10. Implementation of a patient-facing genomic test report in the electronic health record using a web-application interface.

    Science.gov (United States)

    Williams, Marc S; Kern, Melissa S; Lerch, Virginia R; Billet, Jonathan; Williams, Janet L; Moore, Gregory J

    2018-05-30

    Genomic medicine is emerging into clinical care. Communication of genetic laboratory results to patients and providers is hampered by the complex technical nature of the laboratory reports. This can lead to confusion and misinterpretation of the results resulting in inappropriate care. Patients usually do not receive a copy of the report leading to further opportunities for miscommunication. To address these problems, interpretive reports were created using input from the intended end users, patients and providers. This paper describes the technical development and deployment of the first patient-facing genomic test report (PGR) within an electronic health record (EHR) ecosystem using a locally developed standards-based web-application interface. A patient-facing genomic test report with a companion provider report was configured for implementation within the EHR using a locally developed software platform, COMPASS™. COMPASS™ is designed to manage secure data exchange, as well as patient and provider access to patient reported data capture and clinical display tools. COMPASS™ is built using a Software as a Service (SaaS) approach which exposes an API that apps can interact with. An authoring tool was developed that allowed creation of patient-specific PGRs and the accompanying provider reports. These were converted to a format that allowed them to be presented in the patient portal and EHR respectively using the existing COMPASS™ interface thus allowing patients, caregivers and providers access to individual reports designed for the intended end user. The PGR as developed was shown to enhance patient and provider communication around genomic results. It is built on current standards but is designed to support integration with other tools and be compatible with emerging opportunities such as SMART on FHIR. This approach could be used to support genomic return of results as the tool is scalable and generalizable.

  11. Documentation of psychotropic PRN medication administration: An evaluation of electronic health records compared with paper charts and verbal reports.

    Science.gov (United States)

    Martin, Krystle; Ham, Elke; Hilton, Zoe

    2018-05-12

    To describe the documentation of pro re nata (PRN) medication for anxiety, and to compare documentation at two hospitals providing similar psychiatric services, one that used paper charts and another that used an electronic health record (EHR). We also assessed congruence between nursing documentation and verbal reports from staff about the PRN administration process. The ability to accurately document patients' symptoms and the care given is considered a core competency of the nursing profession (Wilkinson, 2007); however, researchers have found poor concordance between nursing notes and verbal reports or observations of events (e.g., De Marinis, Piredda, Pascarella et al., 2009) and considerable information missing (e.g., Marinis et al., 2010). Additionally, the administration of PRN medication has consistently been noted to be poorly documented (e.g., Baker, Lovell, & Harris, 2008). The project was a mixed method, two-phase study that collected data from two sites. In phase 1, nursing documentation of PRN medication administrations was reviewed in patient charts; phase 2 included verbal reports from staff about this practice. Nurses using EHR documented more information than those using paper charts, including the reason for PRN administration, who initiated the administration, and effectiveness. There were some differences between written and verbal reports, including whether potential side effects were explained to patients prior to PRN administration. We continue the calls for attention to be paid to improving the quality of nursing documentation. Our results support the shift to using EHR, yet not relying on this method completely to ensure comprehensiveness of documentation. Efforts to address the quality of documentation, particularly for PRN administration, are needed. This could be done through training, using structured report templates, and switching to electronic databases. This article is protected by copyright. All rights reserved. This article is

  12. Nuclear structure studies by the scattering of medium-energy electrons. Progress report, September 1, 1984-August 31, 1985

    International Nuclear Information System (INIS)

    Peterson, G.A.; Hicks, R.S.

    1985-09-01

    The University of Massachusetts Medium Energy Nuclear Physics Group reports the status of its experimental and theoretical programs. An overview of projects in elastic and quasi-elastic electron scattering which have been completed in the past year is given. Projects which have been designed and which will soon be started are described as well. Descriptions of the theoretical models for nucleon-nucleon interactions, nuclear structure, electromagnetic interactions, and weak interactions are given as well. Listings of the literature of the group are given

  13. Effect of introduction of electronic patient reporting on the duration of ambulance calls.

    Science.gov (United States)

    Kuisma, Markku; Väyrynen, Taneli; Hiltunen, Tuomas; Porthan, Kari; Aaltonen, Janne

    2009-10-01

    We examined the effect of the change from paper records to the electronic patient records (EPRs) on ambulance call duration. We retrieved call duration times 6 months before (group 1) and 6 months after (group 2) the introduction of EPR. Subgroup analysis of group 2 was fulfilled depending whether the calls were made during the first or last 3 months after EPR introduction. We analyzed 37 599 ambulance calls (17 950 were in group 1 and 19 649 were in group 2). The median call duration in group 1 was 48 minutes and in group 2 was 49 minutes (P = .008). In group 2, call duration was longer during the first 3 months after EPR introduction. In multiple linear regression analysis, urgency category (P introduction was noticed, reflecting adaptation process to a new way of working.

  14. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  15. Amorphous NEA Silicon Photocathodes - A Robust RF Gun Electron Source. Final Report

    International Nuclear Information System (INIS)

    Mulhollan, Gregory A.

    2009-01-01

    Amorphous silicon (a-Si) has been shown to have great promise as a negative electron affinity visible wavelength photocathode suitable for radio frequency (RF) gun systems. The specific operating wavelength can be shifted by growing it as a germanium alloy (a-Si(1-x)Ge(x)) rather than as pure silicon. This class of photoemitters has been shown to possess a high degree of immunity to charged particle flux. Such particle flux can be a significant problem in the operation of other photocathodes in RF gun systems. Its emission characteristics in the form of current per unit area, or current density, and emission angle, or beam spread are well matched for use in RF guns. Photocathodes made of a-Si can be fabricated on a variety of substrates including those most commonly employed in RF gun systems. Such photocathodes can be made for operation in either transmission or reflection mode. By growing them utilizing radio frequency plasma enhanced chemical vapor deposition, the unit cost is quite low, the quality is high and it is straightforward to grow custom size substrates and full or limited regions to confine the electron emission to the desired area. Quality emitters have been fabricated on tantalum, molybdenum, tungsten, titanium, copper, stainless steel, float glass, borosilicate glass and gallium arsenide. In addition to performing well in dedicated test chambers, a-Si photocathodes have been shown to function well in self-contained vacuum tubes. In this employment, they are subjected to a strenuous environment. Successful operation in this configuration provides additional confidence in their application to high energy linac photoinjectors and potentially as part of reliable, low cost photocathode driven RF gun systems that could become ready replacements for the diode and triode guns used on medical accelerators. Their applications in stand-alone vacuum tubes is just beginning to be explored.

  16. Previously unreported abnormalities in Wolfram Syndrome Type 2.

    Science.gov (United States)

    Akturk, Halis Kaan; Yasa, Seda

    2017-01-01

    Wolfram syndrome (WFS) is a rare autosomal recessive disease with non-autoimmune childhood onset insulin dependent diabetes and optic atrophy. WFS type 2 (WFS2) differs from WFS type 1 (WFS1) with upper intestinal ulcers, bleeding tendency and the lack ofdiabetes insipidus. Li-fespan is short due to related comorbidities. Only a few familieshave been reported with this syndrome with the CISD2 mutation. Here we report two siblings with a clinical diagnosis of WFS2, previously misdiagnosed with type 1 diabetes mellitus and diabetic retinopathy-related blindness. We report possible additional clinical and laboratory findings that have not been pre-viously reported, such as asymptomatic hypoparathyroidism, osteomalacia, growth hormone (GH) deficiency and hepatomegaly. Even though not a requirement for the diagnosis of WFS2 currently, our case series confirm hypogonadotropic hypogonadism to be also a feature of this syndrome, as reported before. © Polish Society for Pediatric Endocrinology and Diabetology.

  17. 76 FR 56009 - Mandatory Reporting of Greenhouse Gases: Technical Revisions to the Electronics Manufacturing and...

    Science.gov (United States)

    2011-09-09

    ... Distribution Companies in the final rule. New emission factor Yes. formulas are confusing or contain math... place at the field level''. Floating Production No. Storage and Offloading Equipment. API asserted that... CFR 98.230(a)(1)''. Basin level Yes. reporting for onshore petroleum and natural gas production. API...

  18. Tests to evaluate public health disease reporting systems in local public health agencies (electronic resource)

    National Research Council Canada - National Science Library

    Ricci, Karen; Lurie, Nicole; Stoto, Michael A; Wasserman, Jeffrey; Dausey, David J; Meade, Barbara; Diamond, Alexis; Molander, Roger C

    2005-01-01

    ... to evaluate the ability to receive and respond to case reports 24 hours a day, 7 days a week. We refined these tests by beta-testing them at 20 metropolitan area local public health agencies across the country over the course of 10 months. The contents of this manual will be of interest to public health professionals at the state and local l...

  19. 76 FR 37750 - Atlantic Highly Migratory Species; Electronic Dealer Reporting Requirements

    Science.gov (United States)

    2011-06-28

    ... Virginia, reports have been submitted in a paper format to the Southeast Fisheries Science Center (SEFSC..., 901 Airline Drive, Kenner, LA 70062. Panama City, FL July 18, 2011 5-7 p.m Bay County Public Library, 898 West 11th Street, Panama City, FL 32401. Orlando, FL July 19, 2011 5:30-7:30 p.m Jean Rhein...

  20. 78 FR 72818 - Electronic Reporting Under the Toxic Substances Control Act

    Science.gov (United States)

    2013-12-04

    ... password, selects a program and role, and follows the procedures outlined in the CDX user guide available.... How will the agency provide opportunities for potential users to become familiar with the reporting tool? The Agency will offer a webinar open to the public for potential users to become familiar with...

  1. The Effect of Daily Progress Reports on Parental Academic Support: Paper versus Electronic Communication

    Science.gov (United States)

    Schneider, Jonathan D.

    2016-01-01

    In this age of data based decision making and accountability, parent involvement and data collection are paramount. This study represents a significant contribution to educational research by extending the understanding of home-school communication media with specific regard to daily progress reports. The purpose of this study was to compare…

  2. 77 FR 70176 - Previous Participation Certification

    Science.gov (United States)

    2012-11-23

    ... participants' previous participation in government programs and ensure that the past record is acceptable prior... information is designed to be 100 percent automated and digital submission of all data and certifications is... government programs and ensure that the past record is acceptable prior to granting approval to participate...

  3. On the Tengiz petroleum deposit previous study

    International Nuclear Information System (INIS)

    Nysangaliev, A.N.; Kuspangaliev, T.K.

    1997-01-01

    Tengiz petroleum deposit previous study is described. Some consideration about structure of productive formation, specific characteristic properties of petroleum-bearing collectors are presented. Recommendation on their detail study and using of experience on exploration and development of petroleum deposit which have analogy on most important geological and industrial parameters are given. (author)

  4. Subsequent pregnancy outcome after previous foetal death

    NARCIS (Netherlands)

    Nijkamp, J. W.; Korteweg, F. J.; Holm, J. P.; Timmer, A.; Erwich, J. J. H. M.; van Pampus, M. G.

    Objective: A history of foetal death is a risk factor for complications and foetal death in subsequent pregnancies as most previous risk factors remain present and an underlying cause of death may recur. The purpose of this study was to evaluate subsequent pregnancy outcome after foetal death and to

  5. Low cost digital electronics for isotope analysis with microcalorimeters - final report

    International Nuclear Information System (INIS)

    Hennig, W.

    2006-01-01

    The overall goal of the Phase I research was to demonstrate that the digital readout electronics and filter algorithms developed by XIA for use with HPGe detectors can be adapted to high precision, cryogenic gamma detectors (microcalorimeters) and not only match the current state of the art in terms of energy resolution, but do so at a significantly reduced cost. This would make it economically feasible to instrument large arrays of microcalorimeters and would also allow automation of the setup, calibration and operation of large numbers of channels through software. We expected, and have demonstrated, that this approach would further allow much higher count rates than the optimum filter algorithms currently used. In particular, in measurements with a microcalorimeter at LLNL, the adapted Pixie-16 spectrometer achieved an energy resolution of 0.062%, significantly better than the targeted resolution of 0.1% in the Phase I proposal and easily matching resolutions obtained with LLNL readout electronics and optimum filtering (0.066%). The theoretical maximum output count rate for the filter settings used to achieve this resolution is about 120cps. If the filter is adjusted for maximum throughput with an energy resolution of 0.1% or better, rates of 260cps are possible. This is 20-50 times higher than the maximum count rates of about 5cps with optimum filters for this detector. While microcalorimeter measurements were limited to count rates of ∼1.3cps due to the strength of available sources, pulser measurements demonstrated that measured energy resolutions were independent of counting rate to output counting rates well in excess of 200cps or more.. We also developed a preliminary hardware design of a spectrometer module, consisting of a digital processing core and several input options that can be implemented on daughter boards. Depending upon the daughter board, the total parts cost per channel ranged between $12 and $27, resulting in projected product prices of

  6. Low cost digital electronics for isotope analysis with microcalorimeters - final report

    Energy Technology Data Exchange (ETDEWEB)

    W. Hennig

    2006-09-11

    The overall goal of the Phase I research was to demonstrate that the digital readout electronics and filter algorithms developed by XIA for use with HPGe detectors can be adapted to high precision, cryogenic gamma detectors (microcalorimeters) and not only match the current state of the art in terms of energy resolution, but do so at a significantly reduced cost. This would make it economically feasible to instrument large arrays of microcalorimeters and would also allow automation of the setup, calibration and operation of large numbers of channels through software. We expected, and have demonstrated, that this approach would further allow much higher count rates than the optimum filter algorithms currently used. In particular, in measurements with a microcalorimeter at LLNL, the adapted Pixie-16 spectrometer achieved an energy resolution of 0.062%, significantly better than the targeted resolution of 0.1% in the Phase I proposal and easily matching resolutions obtained with LLNL readout electronics and optimum filtering (0.066%). The theoretical maximum output count rate for the filter settings used to achieve this resolution is about 120cps. If the filter is adjusted for maximum throughput with an energy resolution of 0.1% or better, rates of 260cps are possible. This is 20-50 times higher than the maximum count rates of about 5cps with optimum filters for this detector. While microcalorimeter measurements were limited to count rates of ~1.3cps due to the strength of available sources, pulser measurements demonstrated that measured energy resolutions were independent of counting rate to output counting rates well in excess of 200cps or more.. We also developed a preliminary hardware design of a spectrometer module, consisting of a digital processing core and several input options that can be implemented on daughter boards. Depending upon the daughter board, the total parts cost per channel ranged between $12 and $27, resulting in projected product prices of $80

  7. Local atomic and electronic structure in glassy metallic alloys. Final report, March 1, 1979-May 31, 1982

    International Nuclear Information System (INIS)

    Messmer, R.P.; Wong, J.

    1982-01-01

    The research results reported, represent the first coordinated experimental-theoretical effort to arrive at important local atomic and electronic structure information in glassy alloys. During the three years covered by the contract, significant experimental and theoretical developments have taken place both in the general technical community and at General Electric which have had an important impact on the approach to this problem. This is particularly true in the theoretical area where two important advances, the development of a general Xα-LCAO approach, and the development of a general and accurate effective potential approach for density functional methods, have allowed us to construct a new computational capability which combines these two advances. Two subsections briefly review the experimental and theoretical technical developments, respectively. These developments have changed initial perspectives regarding research on local atomic and electronic structure in glassy metallic alloys. Section II presents a synopsis of our accomplishments during the contract period and Section III contains a more detailed discussion of some of these accomplishments, namely those portions of the work which have been published or submitted for publication at the time of writing this final report

  8. Annual Report on Electronics Research at The University of Texas at Austin.

    Science.gov (United States)

    1983-05-15

    Dimensional Information from Image and Motion Analysis." University of Texas Austin, Texas October 6, 1982 M. Fink, " Schopenhauer , Quantum Mechanics...Nonlinear Interactions During Natural Transition of a Wake." xxix PUBLICATIONS, TECHNICAL PRESENTATIONS, LECTURES AND REPORTS Los Alamos National Laboratory...filters. In particular, they present fundamental results on the nature of time-variant digital filters; they discuss the properties of the responses in

  9. Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report.

    Science.gov (United States)

    Ramôa, Carolina P; Hiler, Marzena M; Spindle, Tory R; Lopez, Alexa A; Karaoghlanian, Nareg; Lipato, Thokozeni; Breland, Alison B; Shihadeh, Alan; Eissenberg, Thomas

    2016-04-01

    Electronic cigarettes (ECIGs) aerosolise a liquid that usually contains propylene glycol and/or vegetable glycerine, flavourants and the dependence-producing drug, nicotine, in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration and plasma nicotine concentration and puffing behaviour in experienced ECIG users. Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil 'cartomiser' loaded with 1 mL of a flavoured propylene glycol/vegetable glycerine liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18 or 36 mg/mL). In each session, participants completed two 10-puff ECIG-use bouts (30 s puff interval) separated by 60 min. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume and average flow rate were measured. Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/mL (SD=7.7) for 0 mg/mL liquid, with significantly (pcombustible cigarette. The rationale for this higher level of nicotine delivery is uncertain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Publication and dissemination of Annual Reports to shareholders in Nigeria and the United Kingdom: The Economics of Social Media and Electronic Communication

    Directory of Open Access Journals (Sweden)

    Olagoke Kuye

    2015-06-01

    Full Text Available While the cost of printing and sending out annual reports to shareholders by companies keep increasing and arguments have been made for cheaper and cost-effective ways of carrying out financial disclosure obligations by companies including electronic method, Companies’ Acts maintain that shareholders remain the ultimate decision-maker in the question whether electronic means of publishing annual reports is to be adopted as the primary means of publishing and disseminating annual reports among shareholders. This line of reasoning by legislation is given impetus by the staple assumption that shareholders take the form of owners of the companies of which they are members and the question of what mode of publication and dissemination of annual reports, whether electronic or hard copy remains their exclusive preserve. However, a case is made for a more cost-effective means of carrying out companies’ disclosure obligation through the vehicle of social media and electronic means.

  11. Electron delocalization in α-nitrogen

    International Nuclear Information System (INIS)

    Storchak, V.; Brewer, J.H.; Morris, G.D.; British Columbia Univ., Vancouver, BC

    1995-06-01

    A new technique has been developed for measuring electron drift mobility in crystals on a microscopic scale through its effect on muonium (Mu = μ + + e - ) atom formation via transport of electrons to thermalized positive muons (μ + ). Electron transport mechanisms are shown to be fundamentally different in the α and β phases of solid nitrogen, giving of about 5 orders of magnitude difference in electron mobilities. Contrary to previously reported results of macroscopic time-of-flight measurements, excess electrons appear to be delocalized in α-N 2 . (author). 22 refs., 3 figs

  12. Electronic capture of patient-reported and clinician-reported outcome measures in an elective orthopaedic setting: a retrospective cohort analysis.

    Science.gov (United States)

    Malhotra, Karan; Buraimoh, Olatunbosun; Thornton, James; Cullen, Nicholas; Singh, Dishan; Goldberg, Andrew J

    2016-06-20

    To determine whether an entirely electronic system can be used to capture both patient-reported outcomes (electronic Patient-Reported Outcome Measures, ePROMs) as well as clinician-validated diagnostic and complexity data in an elective surgical orthopaedic outpatient setting. To examine patients' experience of this system and factors impacting their experience. Retrospective analysis of prospectively collected data. Single centre series. Outpatient clinics at an elective foot and ankle unit in the UK. All new adult patients attending elective orthopaedic outpatient clinics over a 32-month period. All patients were invited to complete ePROMs prior to attending their outpatient appointment. At their appointment, those patients who had not completed ePROMs were offered the opportunity to complete it on a tablet device with technical support. Matched diagnostic and complexity data were captured by the treating consultant during the appointment. Capture rates of patient-reported and clinician-reported data. All information and technology (IT) failures, language and disability barriers were captured. Patients were asked to rate their experience of using ePROMs. The scoring systems used included EQ-5D-5L, the Manchester-Oxford Foot Questionnaire (MOxFQ) and the Visual Analogue Scale (VAS) pain score. Out of 2534 new patients, 2176 (85.9%) completed ePROMs, of whom 1090 (50.09%) completed ePROMs at home/work prior to their appointment. 31.5% used a mobile (smartphone/tablet) device. Clinician-reported data were captured on 2491 patients (98.3%). The mean patient experience score of using Patient-Reported Outcome Measures (PROMs) was 8.55±1.85 out of 10 and 666 patients (30.61%) left comments. Of patients leaving comments, 214 (32.13%) felt ePROMs did not adequately capture their symptoms and these patients had significantly lower patient experience scores (ptechnology into a service improvement programme. Excellent capture rates of ePROMs and clinician

  13. Feasibility test of a UK-scalable electronic system for regular collection of patient-reported outcome measures and linkage with clinical cancer registry data: The electronic Patient-reported Outcomes from Cancer Survivors (ePOCS system

    Directory of Open Access Journals (Sweden)

    Velikova Galina

    2011-10-01

    Full Text Available Abstract Background Cancer survivors can face significant physical and psychosocial challenges; there is a need to identify and predict which survivors experience what sorts of difficulties. As highlighted in the UK National Cancer Survivorship Initiative, routine post-diagnostic collection of patient reported outcome measures (PROMs is required; to be most informative, PROMs must be linked and analysed with patients' diagnostic and treatment information. We have designed and built a potentially cost-efficient UK-scalable electronic system for collecting PROMs via the internet, at regular post-diagnostic time-points, for linking these data with patients' clinical data in cancer registries, and for electronically managing the associated patient monitoring and communications; the electronic Patient-reported Outcomes from Cancer Survivors (ePOCS system. This study aims to test the feasibility of the ePOCS system, by running it for 2 years in two Yorkshire NHS Trusts, and using the Northern and Yorkshire Cancer Registry and Information Service. Methods/Design Non-metastatic breast, colorectal and prostate cancer patients (largest survivor groups, within 6 months post-diagnosis, will be recruited from hospitals in the Yorkshire Cancer Network. Participants will be asked to complete PROMS, assessing a range of health-related quality-of-life outcomes, at three time-points up to 15 months post-diagnosis, and subsequently to provide opinion on the ePOCS system via a feedback questionnaire. Feasibility will be examined primarily in terms of patient recruitment and retention rates, the representativeness of participating patients, the quantity and quality of collected PROMs data, patients' feedback, the success and reliability of the underpinning informatics, and the system running costs. If sufficient data are generated during system testing, these will be analysed to assess the health-related quality-of-life outcomes reported by patients, and to explore

  14. Final Report for Award DE-FG02-99ER54554 Kinetics of Electron Fluxes in Low-Pressure Nonthermal Plasmas

    International Nuclear Information System (INIS)

    Uwe Kortshagen

    2004-01-01

    This grant has focused on the study of several aspects of electron kinetics in low pressure plasmas. Entirely new effects arise from the fact that the electron kinetics is governed by non-local effects, in which the electron distribution function is not equilibrium with the local electric field but is governed by spatial transport effects. In this grant, we were able to demonstrate several previously un-studied effects which are a direct result of the nonlocal transport. These are: (1) The existence of a ''convective cell' in electron phase space. The phenomenon was observed and studied in CW plasma conditions. (2) The occurrence of non-collisional cooling of electrons through an effect known as ''diffusive cooling''

  15. Electron beam ion trap bi-annual report 1996/1997

    International Nuclear Information System (INIS)

    Schneider, D.

    1999-01-01

    The research of the EBIT (Electron Beam Ion Trap) program in N Division of the Physics and Space Technology Directorate at LLNL continues to contribute significantly to the understanding of physical processes with low energy highly charged ions in atomic physics, plasma physics, and material science. Low-energy highly charged ions (up to U 92+ ), provided by the EBIT facilities, provide a unique laboratory opportunity to study high field effects in atomic structures and dynamic interaction processes. The formation, existence, and structure of highly charged ions in astrophysical environments and laboratory plasmas make highly charged ions desirable for diagnosing various plasma conditions. The strong interaction of highly charged ions with matter and the response of solid surfaces make them a sensitive analysis tool and possibly a future capability for materials modifications at the atomic scale (nano technology). These physical applications require a good understanding and careful study of the dynamics of the interactions of the ions with complex systems. The EBIT group hosted an international conference and a workshop on trapped charged particles. The various talks and discussions showed that physics research with trapped charged particles is a very active and attractive area of innovative research, and provides a basis for research efforts in new areas. It also became obvious that the EBIT/RETRAP project has unique capabilities to perform important new experiments with trapped very highly charged ions at rest, which are complementary to and competitive with research at heavy ion storage rings and other trapping facilities planned or in operation in Europe, Japan, and the United States. Atomic structure research at EBIT provides ever better and more experimental complete benchmark data, supplying data needed to improve atomic theories. Research highlights through 1996 and 1997 include hyperfine structure measurements in H-like ions, QED studies, lifetime and

  16. Scanning electron microscopy observations of failures of implant overdenture bars: a case series report.

    Science.gov (United States)

    Waddell, J Neil; Payne, Alan G T; Swain, Michael V; Kieser, Jules A

    2010-03-01

    Soldered or cast bars are used as a standard of care in attachment systems supporting maxillary and mandibular implant overdentures. When failures of these bars occur, currently there is a lack of evidence in relation to their specific etiology, location, or nature. To investigate the failure process of a case series of six failed soldered bars, four intact soldered bars, and one intact cast milled bar, which had been supporting implant overdentures. A total of 11 different overdenture bars were removed from patients with different configuration of opposing arches. A failed bar (FB) group (n = 6) had failed soldered overdenture bars, which were recovered from patients following up to 2 years of wear before requiring prosthodontic maintenance and repair. An intact bar (IB) group (n = 5) had both soldered bars and a single cast milled bar, which had been worn by patients for 2 to 5 years prior to receiving other aspects of prosthodontic maintenance. All bars were examined using scanning electron microscopy to establish the possible mode of failure (FB) or to identify evidence of potential failure in the future (IB). Evidence of a progressive failure mode of corrosion fatigue and creep were observed on all the FB and IB usually around the solder areas and nonoxidizing gold cylinder. Fatigue and creep were also observed in all the IB. Where the level of corrosion was substantial, there was no evidence of wear from the matrices of the attachment system. Evidence of an instantaneous failure mode, ductile and brittle overload, was observed on the fracture surfaces of all the FB, within the solder and the nonoxidizing gold cylinders, at the solder/cylinder interface. Corrosion, followed by corrosion fatigue, appears to be a key factor in the onset of the failure process for overdenture bars in this case series of both maxillary and mandibular overdentures. Limited sample size and lack of standardization identify trends only but prevent broad interpretation of the findings.

  17. Electronic document management system analysis report and system plan for the Environmental Restoration Program

    International Nuclear Information System (INIS)

    Frappaolo, C.

    1995-09-01

    Lockheed Martin Energy Systems, Inc. (LMES) has established and maintains Document Management Centers (DMCs) to support Environmental Restoration Program (ER) activities undertaken at three Oak Ridge facilities: Oak Ridge National Laboratory, Oak Ridge K-25 Site, Oak Ridge Y-12 Plant; and two sister sites: Portsmouth Gaseous Diffusion Plant in Portsmouth, Ohio, and Paducah Gaseous Diffusion Plant in Paducah, Kentucky. The role of the DMCs is to receive, store, retrieve, and properly dispose of records. In an effort to make the DMCs run more efficiently and to more proactively manage the records' life cycles from cradle to grave, ER has decided to investigate ways in which Electronic Document Management System (EDMS) technologies can be used to redefine the DMCs and their related processes. Specific goals of this study are tightening control over the ER documents, establishing and enforcing record creation and retention procedures, speeding up access to information, and increasing the accessibility of information. A working pilot of the solution is desired within the next six months. Based on a series of interviews conducted with personnel from each of the DMCs, key management, and individuals representing related projects, it is recommended that ER utilize document management, full-text retrieval, and workflow technologies to improve and automate records management for the ER program. A phased approach to solution implementation is suggested starting with the deployment of an automated storage and retrieval system at Portsmouth. This should be followed with a roll out of the system to the other DMCs, the deployment of a workflow-enabled authoring system at Portsmouth, and a subsequent roll out of this authoring system to the other sites

  18. Deep Impact Delta II Launch Vehicle Cracked Thick Film Coating on Electronic Packages Technical Consultation Report

    Science.gov (United States)

    Cameron, Kenneth D.; Kichak, Robert A.; Piascik, Robert S.; Leidecker, Henning W.; Wilson, Timmy R.

    2009-01-01

    The Deep Impact spacecraft was launched on a Boeing Delta II rocket from Cape Canaveral Air Force Station (CCAFS) on January 12, 2005. Prior to the launch, the Director of the Office of Safety and Mission Assurance (OS&MA) requested the NASA Engineering and Safety Center (NESC) lead a team to render an independent opinion on the rationale for flight and the risk code assignments for the hazard of cracked Thick Film Assemblies (TFAs) in the E-packages of the Delta II launch vehicle for the Deep Impact Mission. The results of the evaluation are contained in this report.

  19. Experiments in high voltage electron microscopy. Progress report, October 31, 1979-July 1980

    International Nuclear Information System (INIS)

    Mitchell, T.E.; Hobbs, L.W.; Mukai, T.; Liu, H.; Pascucci, M.; Youngman, R.A.

    1980-07-01

    Radiation effects in alloys and ceramics are reported. There is a variety of effects of irradiation on phase stability in alloys, including radiation-induced and enhanced phase instability, disordering and secondary defect formation in various alloys. In ceramics, the response to irradiation can be even more complex due to considerations of stoichiometry and imbalance in the spectrum of primary defects (anions and cations). These responses are categorized in three ways: (a) the formation of stoichiometric defects (loops and voids), (b) decomposition or precipitation of a second phase, and (c) transition from the crystalline to the amorphous state

  20. Energy transformation in molecular electronic systems: Progress report, December 1, 1987-November 30, 1988

    International Nuclear Information System (INIS)

    Kasha, M.

    1988-01-01

    Research on proton-transfer spectroscopy is reported. The key findings include (1) observation of excited state proton-transfer in a peptide (benzanilide), (2) the discovery of an extraordinary charge-transfer fluorescence emission in N-methylbenzanilide, which helped to clarify the presence of a dual-fluorescence (in addition to the normal fluorescence) of benzanilide itself, (3) the demostration of an anion-intermediate in the picosecond time-resolved spectroscopy of lumichrome, (4) further studies on the intramolecular proton-transfer laser, including pulse characteristics, and (5) resolution of the non-lasing cases of proton-transfer fluorescence, by SCF calculation and by picosecond time-resolved spectroscopy

  1. Energy transformation in molecular electronic systems: Comprehensive progress report, 1986--1989

    International Nuclear Information System (INIS)

    Kasha, M.

    1989-01-01

    Our research focuses on discovering the fundamental issues in proton-transfer and charge-transfer excitations in model systems, with an eye on which molecular systems will serve as the best guide to biological systems. This report addresses an intramolecular proton transfer classification system, proton-transfer potentials, proton-transfer spectroscopy of benzanilides, proton-transfer in aminosalicylates, proton-transfer in lumichrome, development of proton-transfer lasers, and triplet excitation enhancement via proton-transfer tunneling. 6 refs., 2 figs

  2. Text mining applied to electronic cardiovascular procedure reports to identify patients with trileaflet aortic stenosis and coronary artery disease.

    Science.gov (United States)

    Small, Aeron M; Kiss, Daniel H; Zlatsin, Yevgeny; Birtwell, David L; Williams, Heather; Guerraty, Marie A; Han, Yuchi; Anwaruddin, Saif; Holmes, John H; Chirinos, Julio A; Wilensky, Robert L; Giri, Jay; Rader, Daniel J

    2017-08-01

    Interrogation of the electronic health record (EHR) using billing codes as a surrogate for diagnoses of interest has been widely used for clinical research. However, the accuracy of this methodology is variable, as it reflects billing codes rather than severity of disease, and depends on the disease and the accuracy of the coding practitioner. Systematic application of text mining to the EHR has had variable success for the detection of cardiovascular phenotypes. We hypothesize that the application of text mining algorithms to cardiovascular procedure reports may be a superior method to identify patients with cardiovascular conditions of interest. We adapted the Oracle product Endeca, which utilizes text mining to identify terms of interest from a NoSQL-like database, for purposes of searching cardiovascular procedure reports and termed the tool "PennSeek". We imported 282,569 echocardiography reports representing 81,164 individuals and 27,205 cardiac catheterization reports representing 14,567 individuals from non-searchable databases into PennSeek. We then applied clinical criteria to these reports in PennSeek to identify patients with trileaflet aortic stenosis (TAS) and coronary artery disease (CAD). Accuracy of patient identification by text mining through PennSeek was compared with ICD-9 billing codes. Text mining identified 7115 patients with TAS and 9247 patients with CAD. ICD-9 codes identified 8272 patients with TAS and 6913 patients with CAD. 4346 patients with AS and 6024 patients with CAD were identified by both approaches. A randomly selected sample of 200-250 patients uniquely identified by text mining was compared with 200-250 patients uniquely identified by billing codes for both diseases. We demonstrate that text mining was superior, with a positive predictive value (PPV) of 0.95 compared to 0.53 by ICD-9 for TAS, and a PPV of 0.97 compared to 0.86 for CAD. These results highlight the superiority of text mining algorithms applied to electronic

  3. Measuring Patient Adherence to Malaria Treatment: A Comparison of Results from Self-Report and a Customised Electronic Monitoring Device.

    Science.gov (United States)

    Bruxvoort, Katia; Festo, Charles; Cairns, Matthew; Kalolella, Admirabilis; Mayaya, Frank; Kachur, S Patrick; Schellenberg, David; Goodman, Catherine

    2015-01-01

    Self-report is the most common and feasible method for assessing patient adherence to medication, but can be prone to recall bias and social desirability bias. Most studies assessing adherence to artemisinin-based combination therapies (ACTs) have relied on self-report. In this study, we use a novel customised electronic monitoring device--termed smart blister packs--to examine the validity of self-reported adherence to artemether-lumefantrine (AL) in southern Tanzania. Smart blister packs were designed to look identical to locally available AL blister packs and to record the date and time each tablet was removed from packaging. Patients obtaining AL at randomly selected health facilities and drug stores were followed up at home three days later and interviewed about each dose of AL taken. Blister packs were requested for pill count and extraction of smart blister pack data. Data on adherence from both self-report verified by pill count and smart blister packs were available for 696 of 1,204 patients. There was no difference between methods in the proportion of patients assessed to have completed treatment (64% and 67%, respectively). However, the percentage taking the correct number of pills for each dose at the correct times (timely completion) was higher by self-report than smart blister packs (37% vs. 24%; psmart blister packs, 64% of patients completing treatment did not take the correct number of pills per dose or did not take each dose at the correct time interval. Smart blister packs resulted in lower estimates of timely completion of AL and may be less prone to recall and social desirability bias. They may be useful when data on patterns of adherence are desirable to evaluate treatment outcomes. Improved methods of collecting self-reported data are needed to minimise bias and maximise comparability between studies.

  4. Measuring Patient Adherence to Malaria Treatment: A Comparison of Results from Self-Report and a Customised Electronic Monitoring Device.

    Directory of Open Access Journals (Sweden)

    Katia Bruxvoort

    Full Text Available Self-report is the most common and feasible method for assessing patient adherence to medication, but can be prone to recall bias and social desirability bias. Most studies assessing adherence to artemisinin-based combination therapies (ACTs have relied on self-report. In this study, we use a novel customised electronic monitoring device--termed smart blister packs--to examine the validity of self-reported adherence to artemether-lumefantrine (AL in southern Tanzania.Smart blister packs were designed to look identical to locally available AL blister packs and to record the date and time each tablet was removed from packaging. Patients obtaining AL at randomly selected health facilities and drug stores were followed up at home three days later and interviewed about each dose of AL taken. Blister packs were requested for pill count and extraction of smart blister pack data.Data on adherence from both self-report verified by pill count and smart blister packs were available for 696 of 1,204 patients. There was no difference between methods in the proportion of patients assessed to have completed treatment (64% and 67%, respectively. However, the percentage taking the correct number of pills for each dose at the correct times (timely completion was higher by self-report than smart blister packs (37% vs. 24%; p<0.0001. By smart blister packs, 64% of patients completing treatment did not take the correct number of pills per dose or did not take each dose at the correct time interval.Smart blister packs resulted in lower estimates of timely completion of AL and may be less prone to recall and social desirability bias. They may be useful when data on patterns of adherence are desirable to evaluate treatment outcomes. Improved methods of collecting self-reported data are needed to minimise bias and maximise comparability between studies.

  5. Medicare and Medicaid programs: Hospital Outpatient Prospective Payment and Ambulatory Surgical Center Payment Systems and Quality Reporting Programs; electronic reporting pilot; Inpatient Rehabilitation Facilities Quality Reporting Program; revision to Quality Improvement Organization regulations. Final rule with comment period.

    Science.gov (United States)

    2012-11-15

    This final rule with comment period revises the Medicare hospital outpatient prospective payment system (OPPS) and the Medicare ambulatory surgical center (ASC) payment system for CY 2013 to implement applicable statutory requirements and changes arising from our continuing experience with these systems. In this final rule with comment period, we describe the changes to the amounts and factors used to determine the payment rates for Medicare services paid under the OPPS and those paid under the ASC payment system. In addition, this final rule with comment period updates and refines the requirements for the Hospital Outpatient Quality Reporting (OQR) Program, the ASC Quality Reporting (ASCQR) Program, and the Inpatient Rehabilitation Facility (IRF) Quality Reporting Program. We are continuing the electronic reporting pilot for the Electronic Health Record (EHR) Incentive Program, and revising the various regulations governing Quality Improvement Organizations (QIOs), including the secure transmittal of electronic medical information, beneficiary complaint resolution and notification processes, and technical changes. The technical changes to the QIO regulations reflect CMS' commitment to the general principles of the President's Executive Order on Regulatory Reform, Executive Order 13563 (January 18, 2011).

  6. Previously undiagnosed hemophilia patient with intracerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Eray Atalay

    2015-09-01

    Full Text Available Intracranial bleeding in hemophilia patients is a rare but a mortal complication. Diagnosis of hemophilia in adulthood is an uncommon occurrence. In this case report an adult patient with intracranial hemorrhage is presented.

  7. Integrating patient reported outcomes with clinical cancer registry data: a feasibility study of the electronic Patient-Reported Outcomes From Cancer Survivors (ePOCS) system.

    Science.gov (United States)

    Ashley, Laura; Jones, Helen; Thomas, James; Newsham, Alex; Downing, Amy; Morris, Eva; Brown, Julia; Velikova, Galina; Forman, David; Wright, Penny

    2013-10-25

    Routine measurement of Patient Reported Outcomes (PROs) linked with clinical data across the patient pathway is increasingly important for informing future care planning. The innovative electronic Patient-reported Outcomes from Cancer Survivors (ePOCS) system was developed to integrate PROs, collected online at specified post-diagnostic time-points, with clinical and treatment data in cancer registries. This study tested the technical and clinical feasibility of ePOCS by running the system with a sample of potentially curable breast, colorectal, and prostate cancer patients in their first 15 months post diagnosis. Patients completed questionnaires comprising multiple Patient Reported Outcome Measures (PROMs) via ePOCS within 6 months (T1), and at 9 (T2) and 15 (T3) months, post diagnosis. Feasibility outcomes included system informatics performance, patient recruitment, retention, representativeness and questionnaire completion (response rate), patient feedback, and administration burden involved in running the system. ePOCS ran efficiently with few technical problems. Patient participation was 55.21% (636/1152) overall, although varied by approach mode, and was considerably higher among patients approached face-to-face (61.4%, 490/798) than by telephone (48.8%, 21/43) or letter (41.0%, 125/305). Older and less affluent patients were less likely to join (both Pplanning and for targeting service provision.

  8. Herpetic brainstem encephalitis: report of a post-mortem case studied electron microscopically and immunohisiochemically

    Directory of Open Access Journals (Sweden)

    José Eymard Homem Pitella

    1987-03-01

    Full Text Available A post-mortem examined case of herpetic brainstem encephalitis is presented. Clinically, the patient had cephalea followed by ataxia, drowsiness and multiple palsies of some cranial nerves, developing into death in eight days. The pathologic examination of the brain showed necrotizing encephalitis in multiple foci limited to the brainstem, more distinctly in the pons and medula oblongata. The technique of immunoperoxidase revealed rare glial cells with intranuclear immunoreactivity for herpes antigen. Rare viral particles with the morphological characteristics of the herpesvirus were identified in the nuclei of neurons in 10% formol fixed material. This is the second reported case of herpetic brainstem encephalitis confirmed by post-mortem examination. The pathway used by the virus to reach the central nervous system and its posterior dissemination to the oral cavity, the orbitofrontal region and the temporal lobes as well as to the brainstem, after a period of latency and reactivation, are discussed.

  9. Surface and interface electronic structure: Final report, December 1, 1994--November 30, 1995

    International Nuclear Information System (INIS)

    Kevan, S.D.

    1995-01-01

    A year and a half ago, we terminated our operations at the National Synchrotron Light Source and moved our research program to the Advanced Light Source in Berkeley. This move was motivated primarily by the exciting possibilities and research directions made possible by operation at the newer ALS facility. The ALS facility was commissioned in October 1993. We are members of a 'Participating Research Team' (PRT) associated with undulator beamline 7.0 at the ALS. This beamline was commissioned for experiments the following winter and spring of 1994. We have thus had about a year to debug the beamline and to try to get some experiments accomplished. Reportedly due to insufficient operating funds, the facility provided beam to users only nine 8-hour shifts per week. In the past year, our program has been devoted primarily to becoming operational at the ALS and to assembling experiments and experimental equipment associated with our program there

  10. Surface and interface electronic structure: Final report, December 1, 1994--November 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Kevan, S.D.

    1995-12-31

    A year and a half ago, we terminated our operations at the National Synchrotron Light Source and moved our research program to the Advanced Light Source in Berkeley. This move was motivated primarily by the exciting possibilities and research directions made possible by operation at the newer ALS facility. The ALS facility was commissioned in October 1993. We are members of a `Participating Research Team` (PRT) associated with undulator beamline 7.0 at the ALS. This beamline was commissioned for experiments the following winter and spring of 1994. We have thus had about a year to debug the beamline and to try to get some experiments accomplished. Reportedly due to insufficient operating funds, the facility provided beam to users only nine 8-hour shifts per week. In the past year, our program has been devoted primarily to becoming operational at the ALS and to assembling experiments and experimental equipment associated with our program there.

  11. Haemophilus influenzae type f meningitis in a previously healthy boy

    DEFF Research Database (Denmark)

    Ronit, Andreas; Berg, Ronan M G; Bruunsgaard, Helle

    2013-01-01

    Non-serotype b strains of Haemophilus influenzae are extremely rare causes of acute bacterial meningitis in immunocompetent individuals. We report a case of acute bacterial meningitis in a 14-year-old boy, who was previously healthy and had been immunised against H influenzae serotype b (Hib...

  12. Process cells dismantling of EUREX pant: previous activities

    International Nuclear Information System (INIS)

    Gili, M.

    1998-01-01

    In the '98-'99 period some process cells of the EUREX pant will be dismantled, in order to place there the liquid wastes conditioning plant 'CORA'. This report resumes the previous activities (plant rinsing campaigns and inactive Cell 014 dismantling), run in the past three years and the drawn experience [it

  13. Electron beam welding of copper lids. Status report up to 2001-12-31

    International Nuclear Information System (INIS)

    Claesson, Soeren; Ronneteg, Ulf

    2003-10-01

    The report describes a summary of achieved results from 21 lid welds and numerous test block welds, performed at SKB Canister Laboratory in Oskarshamn for the period 1999-02-12 to 2001-12-31. Good weld quality has been achieved and some welds fulfilled the preliminary interpretation criteria, but the weld process need to be further developed before process qualification. Many different parameter settings have been tested and the influence on the weld profile has been mapped and documented. Deformations of the canister after welding have been measured and found to be very small. The preliminary inspection methods of the weld quality works satisfactory for the need of the development of the weld process. The welding machine is a new design developed for welding of thick copper in reduced pressure and performs well, but suffers from teething problems, which has delayed the work with development of the weld process. The welding system needs to be further developed and improved to work more reliably in a production plant

  14. Electron spin polarization effects in low energy electron diffraction, ion neutralization and metastable atom deexcitation at solid surfaces. Progress report No. 4, 1 January-31 December 1984

    International Nuclear Information System (INIS)

    1984-01-01

    In the present contract year, a GaAs polarized electron source has been used to undertake a polarized LEED study of order-disorder transformations at Cu 3 Au (100) and (111) surfaces. A polarized LEED study of Cu (100) has also been initiated. A polarized MDS study of Ni(110) surface magnetism has been completed. Spin dependences in the Auger electron yield were observed that provide a measure of the surface magnetism and were used to probe the dependence of surface magnetism on temperature and adsorbate coverage. A similar study using a ferromagnetic glass is now underway. A Mott polarization analyzer, constructed to measure the ESP of the ejected electrons, is also being installed on the apparatus. Such measurements provide direct information concerning the dynamics of secondary electron ejection and the details of adsorbate-substrate bonding

  15. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Curran, Bruce; Cygler, Joanna E.; DeMarco, John J.; Ezzell, Gary; Faddegon, Bruce A.; Kawrakow, Iwan; Keall, Paul J.; Liu, Helen; Ma, C.-M. Charlie; Rogers, D. W. O.; Seuntjens, Jan; Sheikh-Bagheri, Daryoush; Siebers, Jeffrey V.

    2007-01-01

    The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. These advances have motivated several major treatment planning system vendors to embark upon the path of MC techniques. Several commercial vendors have already released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. The purpose of this report, while providing education and review on the use of MC simulation in radiotherapy planning, is to set out, for both users and developers, the salient issues associated with clinical implementation and

  16. Pulsed WIP electron gun. Final report: design phase 1 x 70 cm cooled WIP electron gun, 1 December 1978--2 February 1979

    International Nuclear Information System (INIS)

    Wakalopulos, G.; Gresko, L.

    1979-01-01

    Presented here are design criteria for a full scale (70 cm) WIP electron gun system capable of long run operation with the following specifications: foil area approx. 70 x 1 cm, electron beam current density approx. 1 A/cm 2 , pulse length 2 , voltage -150 kV, voltage droop < 10%, Rep rate approx. 10 KHz, power approx. 20 kW, run time approx. 30 min, and jitter approx. 10 μs

  17. Report of Snowmass 2001 Working Group E2: Electron-Positron Colliders from the Phi to the Z

    Energy Technology Data Exchange (ETDEWEB)

    Decker, Franz-Josef

    2002-08-07

    We report on the status and plans of experiments now running or proposed for electron-positron colliders at energies between the {phi} and the Z. The e{sup +}e{sup -} B and charm factories we considered were PEP-II/BABAR, KEKB/Belle, superKEK, SuperBABAR, and CESR-c/CLEO-c. We reviewed the programs at the {phi} factory at Frascati and the proposed PEP-N facility at Stanford Linear Accelerator Center. We studied the prospects for B physics with a dedicated linear collider Z factory, associated with the TESLA high energy linear collider. In all cases, we compared the physics reach of these facilities with that of alternative experiments at hadron colliders or fixed target facilities.

  18. Novel Power Electronics Systems for Wind Energy Applications: Final Report; Period of Performance: August 24, 1999 -- November 30, 2002

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, R.; Angkititrakul, S.; Al-Naseem, O.; Lujan, G.

    2004-10-01

    The objective of this work was to develop new approaches to the power electronics of variable-speed wind power systems, with the goal of improving the associated cost of energy. Of particular importance is the converter efficiency at low-wind operating points. Developing converter approaches that maintain high efficiency at partial power, without sacrificing performance at maximum power, is desirable, as is demonstrating an approach that can use emerging power component technologies to attain these performance goals with low projected capital costs. In this report, we show that multilevel conversion is an approach that can meet these performance requirements. In the wind power application, multilevel conversion proves superior to conventional converter technologies because it is callable to high power and higher voltage levels, it extends the range of high converter efficiency to lower wind speeds, and it allows superior low-voltage fast-switching semiconductor devices to be used in high-voltage high-power applications.

  19. MCNP HPGe detector benchmark with previously validated Cyltran model.

    Science.gov (United States)

    Hau, I D; Russ, W R; Bronson, F

    2009-05-01

    An exact copy of the detector model generated for Cyltran was reproduced as an MCNP input file and the detection efficiency was calculated similarly with the methodology used in previous experimental measurements and simulation of a 280 cm(3) HPGe detector. Below 1000 keV the MCNP data correlated to the Cyltran results within 0.5% while above this energy the difference between MCNP and Cyltran increased to about 6% at 4800 keV, depending on the electron cut-off energy.

  20. Final Test Report: Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

    Science.gov (United States)

    Kessel, Kurt R.

    2016-01-01

    The test results for Salt Spray Resistance, Static Heat and Humidity and Marine Environment can be found in Sections 3.1.3.3, 3.1.4.3 and 3.1.5.3 respectively. In summary, both the Metalast TCP and SurTec 650 Type 2 conversion coatings perform very similar to the incumbent Type 1 conversion coating against both 6061 and 5052 aluminum under all three test conditions. Significant prior work was performed to select the aluminum and conversion coating included within this test cycle; Reference - NASA GSDO Program Hexavalent Chrome Alternatives Final Pretreatments Test Report Task Order: NNH12AA45D September 01, 2013. As illustrated in the data, the 6061 aluminum panels SLIGHTLY out-performed the 5052 aluminum panels. Individual shielding effectiveness graphs for each panel are included within Appendix C and D. One other notable effect found during review of the data is that the Test Panels exposed to B117 Salt Fog reduced in shielding effectiveness significantly more than the Marine Environment Test Panels. The shielding effectiveness of the Marine Test Panels was approximately 20dB higher than the Test Panels that underwent B117 Salt Fog Exposure. The intent of this evaluation was not to maximize shielding effectiveness values. The same Parker Chomerics Cho-Seal 6503 gasket material was used for all panels with aluminum and conversion coating variants. A typical EMI gasket design for corrosive environments would be done quite differently. The intent was to execute a test that would provide the best possible evaluation of different aluminum materials and conversion coatings in corrosive environments. The test program achieved this intent. The fact that the two aluminums and two Type II conversion coatings performed similar to the incumbent Type 1 conversion coating is a positive outcome. It was desired to have an outcome that further differentiation the performance of two aluminum types and two conversion coating types but this could not be extracted by the test

  1. Advanced Electronics

    Science.gov (United States)

    2017-07-21

    AFRL-RV-PS- AFRL-RV-PS- TR-2017-0114 TR-2017-0114 ADVANCED ELECTRONICS Ashwani Sharma 21 Jul 2017 Interim Report APPROVED FOR PUBLIC RELEASE...NUMBER Advanced Electronics 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62601F 6. AUTHOR(S) 5d. PROJECT NUMBER 4846 Ashwani Sharma 5e. TASK NUMBER...Approved for public release; distribution is unlimited. (RDMX-17-14919 dtd 20 Mar 2018) 13. SUPPLEMENTARY NOTES 14. ABSTRACT The Space Electronics

  2. Books average previous decade of economic misery.

    Science.gov (United States)

    Bentley, R Alexander; Acerbi, Alberto; Ormerod, Paul; Lampos, Vasileios

    2014-01-01

    For the 20(th) century since the Depression, we find a strong correlation between a 'literary misery index' derived from English language books and a moving average of the previous decade of the annual U.S. economic misery index, which is the sum of inflation and unemployment rates. We find a peak in the goodness of fit at 11 years for the moving average. The fit between the two misery indices holds when using different techniques to measure the literary misery index, and this fit is significantly better than other possible correlations with different emotion indices. To check the robustness of the results, we also analysed books written in German language and obtained very similar correlations with the German economic misery index. The results suggest that millions of books published every year average the authors' shared economic experiences over the past decade.

  3. Books Average Previous Decade of Economic Misery

    Science.gov (United States)

    Bentley, R. Alexander; Acerbi, Alberto; Ormerod, Paul; Lampos, Vasileios

    2014-01-01

    For the 20th century since the Depression, we find a strong correlation between a ‘literary misery index’ derived from English language books and a moving average of the previous decade of the annual U.S. economic misery index, which is the sum of inflation and unemployment rates. We find a peak in the goodness of fit at 11 years for the moving average. The fit between the two misery indices holds when using different techniques to measure the literary misery index, and this fit is significantly better than other possible correlations with different emotion indices. To check the robustness of the results, we also analysed books written in German language and obtained very similar correlations with the German economic misery index. The results suggest that millions of books published every year average the authors' shared economic experiences over the past decade. PMID:24416159

  4. FY2007 Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery Program

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Mitchell [ORNL

    2007-10-01

    as a complete propulsion system and whether the efficiency and performance targets at the vehicle level have been achieved. The research performed under this subprogram will help remove technical and cost barriers to enable the development of technology for use in such advanced vehicles as hybrid and fuel-cell-powered automobiles that meet the goals of the FreedomCAR and Vehicle Technologies Program. A key element in making hybrid electric vehicles (HEVs) practical is providing an affordable electric traction drive system. This will require attaining weight, volume, and cost targets for the power electronics and electrical machines subsystems of the traction drive system. Areas of development include these: (1) novel traction motor designs that result in increased power density and lower cost; (2) inverter technologies involving new topologies to achieve higher efficiency and the ability to accommodate higher-temperature environments; (3) converter concepts that employ means of reducing the component count and integrating functionality to decrease size, weight, and cost; (4) more effective thermal control and packaging technologies; and (5) integrated motor/inverter concepts. The Oak Ridge National Laboratory's (ORNL's) Power Electronics and Electric Machinery Research Center conducts fundamental research, evaluates hardware, and assists in the technical direction of the DOE Office of FreedomCAR and Vehicle Technologies Program, APEEM subprogram. In this role, ORNL serves on the FreedomCAR Electrical and Electronics Technical Team, evaluates proposals for DOE, and lends its technological expertise to the direction of projects and evaluation of developing technologies. ORNL also executes specific projects for DOE. The following report discusses those projects carried out in FY 2007 and conveys highlights of their accomplishments. Numerous project reviews, technical reports, and papers have been published for these efforts, if the reader is interested in

  5. Common data elements for secondary use of electronic health record data for clinical trial execution and serious adverse event reporting

    Directory of Open Access Journals (Sweden)

    Philipp Bruland

    2016-11-01

    Full Text Available Abstract Background Data capture is one of the most expensive phases during the conduct of a clinical trial and the increasing use of electronic health records (EHR offers significant savings to clinical research. To facilitate these secondary uses of routinely collected patient data, it is beneficial to know what data elements are captured in clinical trials. Therefore our aim here is to determine the most commonly used data elements in clinical trials and their availability in hospital EHR systems. Methods Case report forms for 23 clinical trials in differing disease areas were analyzed. Through an iterative and consensus-based process of medical informatics professionals from academia and trial experts from the European pharmaceutical industry, data elements were compiled for all disease areas and with special focus on the reporting of adverse events. Afterwards, data elements were identified and statistics acquired from hospital sites providing data to the EHR4CR project. Results The analysis identified 133 unique data elements. Fifty elements were congruent with a published data inventory for patient recruitment and 83 new elements were identified for clinical trial execution, including adverse event reporting. Demographic and laboratory elements lead the list of available elements in hospitals EHR systems. For the reporting of serious adverse events only very few elements could be identified in the patient records. Conclusions Common data elements in clinical trials have been identified and their availability in hospital systems elucidated. Several elements, often those related to reimbursement, are frequently available whereas more specialized elements are ranked at the bottom of the data inventory list. Hospitals that want to obtain the benefits of reusing data for research from their EHR are now able to prioritize their efforts based on this common data element list.

  6. Common data elements for secondary use of electronic health record data for clinical trial execution and serious adverse event reporting.

    Science.gov (United States)

    Bruland, Philipp; McGilchrist, Mark; Zapletal, Eric; Acosta, Dionisio; Proeve, Johann; Askin, Scott; Ganslandt, Thomas; Doods, Justin; Dugas, Martin

    2016-11-22

    Data capture is one of the most expensive phases during the conduct of a clinical trial and the increasing use of electronic health records (EHR) offers significant savings to clinical research. To facilitate these secondary uses of routinely collected patient data, it is beneficial to know what data elements are captured in clinical trials. Therefore our aim here is to determine the most commonly used data elements in clinical trials and their availability in hospital EHR systems. Case report forms for 23 clinical trials in differing disease areas were analyzed. Through an iterative and consensus-based process of medical informatics professionals from academia and trial experts from the European pharmaceutical industry, data elements were compiled for all disease areas and with special focus on the reporting of adverse events. Afterwards, data elements were identified and statistics acquired from hospital sites providing data to the EHR4CR project. The analysis identified 133 unique data elements. Fifty elements were congruent with a published data inventory for patient recruitment and 83 new elements were identified for clinical trial execution, including adverse event reporting. Demographic and laboratory elements lead the list of available elements in hospitals EHR systems. For the reporting of serious adverse events only very few elements could be identified in the patient records. Common data elements in clinical trials have been identified and their availability in hospital systems elucidated. Several elements, often those related to reimbursement, are frequently available whereas more specialized elements are ranked at the bottom of the data inventory list. Hospitals that want to obtain the benefits of reusing data for research from their EHR are now able to prioritize their efforts based on this common data element list.

  7. Previous Experience a Model of Practice UNAE

    OpenAIRE

    Ormary Barberi Ruiz; María Dolores Pesántez Palacios

    2017-01-01

    The statements presented in this article represents a preliminary version of the proposed model of pre-professional practices (PPP) of the National University of Education (UNAE) of Ecuador, an urgent institutional necessity is revealed in the descriptive analyzes conducted from technical support - administrative (reports, interviews, testimonials), pedagogical foundations of UNAE (curricular directionality, transverse axes in practice, career plan, approach and diagnostic examination as subj...

  8. Advanced electron beam techniques

    International Nuclear Information System (INIS)

    Hirotsu, Yoshihiko; Yoshida, Yoichi

    2007-01-01

    After 100 years from the time of discovery of electron, we now have many applications of electron beam in science and technology. In this report, we review two important applications of electron beam: electron microscopy and pulsed-electron beam. Advanced electron microscopy techniques to investigate atomic and electronic structures, and pulsed-electron beam for investigating time-resolved structural change are described. (author)

  9. Using Electronic Health Records to Support Clinical Trials: A Report on Stakeholder Engagement for EHR4CR.

    Science.gov (United States)

    McCowan, Colin; Thomson, Elizabeth; Szmigielski, Cezary A; Kalra, Dipak; Sullivan, Frank M; Prokosch, Hans-Ulrich; Dugas, Martin; Ford, Ian

    2015-01-01

    The conduct of clinical trials is increasingly challenging due to greater complexity and governance requirements as well as difficulties with recruitment and retention. Electronic Health Records for Clinical Research (EHR4CR) aims at improving the conduct of trials by using existing routinely collected data, but little is known about stakeholder views on data availability, information governance, and acceptable working practices. Senior figures in healthcare organisations across Europe were provided with a description of the project and structured interviews were subsequently conducted to elicit their views. 37 structured interviewees in Germany, UK, Switzerland, and France indicated strong support for the proposed EHR4CR platform. All interviewees reported that using the platform for assessing feasibility would enhance the conduct of clinical trials and the majority also felt it would reduce workloads. Interviewees felt the platform could enhance trial recruitment and adverse event reporting but also felt it could raise either ethical or information governance concerns in their country. There was clear support for EHR4CR and a belief that it could reduce workloads and improve the conduct and quality of trials. However data security, privacy, and information governance issues would need to be carefully managed in the development of the platform.

  10. Using Electronic Health Records to Support Clinical Trials: A Report on Stakeholder Engagement for EHR4CR

    Directory of Open Access Journals (Sweden)

    Colin McCowan

    2015-01-01

    Full Text Available Background. The conduct of clinical trials is increasingly challenging due to greater complexity and governance requirements as well as difficulties with recruitment and retention. Electronic Health Records for Clinical Research (EHR4CR aims at improving the conduct of trials by using existing routinely collected data, but little is known about stakeholder views on data availability, information governance, and acceptable working practices. Methods. Senior figures in healthcare organisations across Europe were provided with a description of the project and structured interviews were subsequently conducted to elicit their views. Results. 37 structured interviewees in Germany, UK, Switzerland, and France indicated strong support for the proposed EHR4CR platform. All interviewees reported that using the platform for assessing feasibility would enhance the conduct of clinical trials and the majority also felt it would reduce workloads. Interviewees felt the platform could enhance trial recruitment and adverse event reporting but also felt it could raise either ethical or information governance concerns in their country. Conclusions. There was clear support for EHR4CR and a belief that it could reduce workloads and improve the conduct and quality of trials. However data security, privacy, and information governance issues would need to be carefully managed in the development of the platform.

  11. LDRD final report for improving human effectiveness for extreme-scale problem solving : assessing the effectiveness of electronic brainstorming in an industrial setting.

    Energy Technology Data Exchange (ETDEWEB)

    Dornburg, Courtney C.; Stevens, Susan Marie; Davidson, George S.; Hendrickson, Stacey M. Langfitt

    2008-09-01

    An experiment was conducted comparing the effectiveness of individual versus group electronic brainstorming in order to address difficult, real world challenges. While industrial reliance on electronic communications has become ubiquitous, empirical and theoretical understanding of the bounds of its effectiveness have been limited. Previous research using short-term, laboratory experiments have engaged small groups of students in answering questions irrelevant to an industrial setting. The present experiment extends current findings beyond the laboratory to larger groups of real-world employees addressing organization-relevant challenges over the course of four days. Employees and contractors at a national security laboratory participated, either in a group setting or individually, in an electronic brainstorm to pose solutions to a 'wickedly' difficult problem. The data demonstrate that (for this design) individuals perform at least as well as groups in producing quantity of electronic ideas, regardless of brainstorming duration. However, when judged with respect to quality along three dimensions (originality, feasibility, and effectiveness), the individuals significantly (p<0.05) out-performed the group working together. When idea quality is used as the benchmark of success, these data indicate that work-relevant challenges are better solved by aggregating electronic individual responses, rather than electronically convening a group. This research suggests that industrial reliance upon electronic problem solving groups should be tempered, and large nominal groups might be the more appropriate vehicle for solving wicked corporate issues.

  12. Study of the motion of electrons in non polar classical liquids. Measurement of Hall effect and f.i.r. search for low energy traps. Progress report

    International Nuclear Information System (INIS)

    1981-01-01

    Progress is reported on experiments aimed at the measurement of the Hall mobility of injected electrons in classical non polar insulating liquids and the optical absorption associated with electrons captured by shallow traps in the liquefied rare gases. Theoretical work aimed at a better understanding of the trapping kinetics of electrons by SF 6 and O 2 dissolved in rare gas liquids was also carried out. Its conclusion is that the electric field dependence of the trapping probability can be explained, basically without adjustable parameters, by considering the Poole-Frenkel-Schotky ionization of the excited state of the traps. From the analysis of published data on the motion of electrons in liquid ethane it is tentatively concluded that at low temperatures the trapping of electrons in the liquid involves a Jahn-Teller like distortion of a single ethane molecule while at higher temperatures it is necessary to consider a small molecular cluster, possibly made up of 2 molecules

  13. Microfluidic electronics.

    Science.gov (United States)

    Cheng, Shi; Wu, Zhigang

    2012-08-21

    Microfluidics, a field that has been well-established for several decades, has seen extensive applications in the areas of biology, chemistry, and medicine. However, it might be very hard to imagine how such soft microfluidic devices would be used in other areas, such as electronics, in which stiff, solid metals, insulators, and semiconductors have previously dominated. Very recently, things have radically changed. Taking advantage of native properties of microfluidics, advances in microfluidics-based electronics have shown great potential in numerous new appealing applications, e.g. bio-inspired devices, body-worn healthcare and medical sensing systems, and ergonomic units, in which conventional rigid, bulky electronics are facing insurmountable obstacles to fulfil the demand on comfortable user experience. Not only would the birth of microfluidic electronics contribute to both the microfluidics and electronics fields, but it may also shape the future of our daily life. Nevertheless, microfluidic electronics are still at a very early stage, and significant efforts in research and development are needed to advance this emerging field. The intention of this article is to review recent research outcomes in the field of microfluidic electronics, and address current technical challenges and issues. The outlook of future development in microfluidic electronic devices and systems, as well as new fabrication techniques, is also discussed. Moreover, the authors would like to inspire both the microfluidics and electronics communities to further exploit this newly-established field.

  14. Using High-Technology Simulators to Prepare Anesthesia Providers Before Implementation of a New Electronic Health Record Module: A Technical Report.

    Science.gov (United States)

    Weintraub, Ari Y; Deutsch, Ellen S; Hales, Roberta L; Buchanan, Newton A; Rock, Whitney L; Rehman, Mohamed A

    2017-06-01

    Learning to use a new electronic anesthesia information management system can be challenging. Documenting anesthetic events, medication administration, and airway management in an unfamiliar system while simultaneously caring for a patient with the vigilance required for safe anesthesia can be distracting and risky. This technical report describes a vendor-agnostic approach to training using a high-technology manikin in a simulated clinical scenario. Training was feasible and valued by participants but required a combination of electronic and manual components. Further exploration may reveal simulated patient care training that provides the greatest benefit to participants as well as feedback to inform electronic health record improvements.

  15. [Theoretical studies of dynamics and correlations in heavy electron materials:]: Progress report, August 15, 1987-August 15, 1988

    International Nuclear Information System (INIS)

    1988-01-01

    This paper discusses progress in heavy electron research and high temperature superconductivity research. Particular topics discussed are: quadrupolar Kondo effect; coherence in the Anderson Lattice; Hall effect in heavy electron systems, suppression of supeconductivity by disorder in strongly correlated electronic materials; and charge transfer mechanisms for high temperature superconductivity

  16. 75 FR 3463 - Cross-Media Electronic Reporting Rule State Authorized Program Revision Approval: State of North...

    Science.gov (United States)

    2010-01-21

    ... consideration of the electronic document receiving systems that the state, tribe, or local government will use... for its Integrated Build Environment for Application Management (IBEAM) electronic document receiving... to assure that electronic documents are as legally dependable as their paper counterparts. Subpart D...

  17. Electronics Industry Study Report

    Science.gov (United States)

    2005-01-01

    nearest rival, Korea’s Samsung , by a factor of 2:1 with more than $30 billion in sales and $7.5 billion profit in 2004, although Intel has been losing...firms, conversely, have built their reputations and sales volume on lower end commodities. Korea’s Samsung , and Germany’s Infineon, for example, are...facilities in China, Costa Rica, Ireland, Israel, Malaysia , and the Philippines.14 Texas Instruments has over 15,000 employees in production

  18. Excitation and ionization of highly charged ions by electron impact. Progress report, January 1, 1978-July 31, 1979

    International Nuclear Information System (INIS)

    Sampson, D.H.

    1979-07-01

    Reduced ionization cross sections Q/sub R//sup H/(nl,u) were obtained for the nl = 3p and 3d sublevels, as well as for more energy points for the lower sublevels considered in our earlier work. Thus, results are now available for the eight impact electron energies in threshold units u = 1.125, 1.25, 1.5, 2.25, 3.0, 4.0, 5.0, and 6.0 for each of the sublevels 1s, 2s, 2p, 3s, 3p, and 3d. From these results for Q/sub R//sup H/(nl,u) one can readily obtain the cross section for ionization from any of these sublevels in any highly charged complex ion using the simple procedures given in our earlier work. The theory and computer programs developed in our previous work on excitation were used to calculate intermediate coupling collision strengths for all fine structure transitions from the 2P levels to the nP and nD levels with 3 less than or equal to n less than or equal to 5 in He-like ions. Similar calculations have also been made for inner shell excitation of Li-like ions with nuclear charge number Z in the range 10 less than or equal to Z less than or equal to 74. The theory and programs were also extended to treat Δn = 0 transitions and were used to obtain intermediate coupling collision strengths for all Δn = 0 fine structure transitions with n = 2 in 10 He-like ions with Z in the range 6 less than or equal to Z less than or equal to 74 and 10 Be-like ions with Z in the range 14 less than or equal to Z less than or equal to 74. For excitation the results appear to be accurate to within approx. 30% for 3N less than or equal to Z less than or equal to 74, where N is the number of bound electrons per ion, and more accurate for most of this range. For ionization the results appear to be accurate down to Z/N approx. = 2. 21 references

  19. Electronics and Information

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Previously founded as CCPITMachinery and Electronics Sub-council and CCOIC Machinery and Electronics Chamber of Corn-merce in June, 1988, CCPIT Electronics Sub-Council and CCOIC Electronics Chamber of Commerce were established in May, 1993, and then renamed as CCPIT Electronics and Information Industry Sub-council and CCOIC Electronics and Infor-mation Industry Chamber of Commerce (CCPITECC) in September 1999.

  20. Electron attachment rate constant measurement by photoemission electron attachment ion mobility spectrometry (PE-EA-IMS)

    International Nuclear Information System (INIS)

    Su, Desheng; Niu, Wenqi; Liu, Sheng; Shen, Chengyin; Huang, Chaoqun; Wang, Hongmei; Jiang, Haihe; Chu, Yannan

    2012-01-01

    Photoemission electron attachment ion mobility spectrometry (PE-EA-IMS), with a source of photoelectrons induced by vacuum ultraviolet radiation on a metal surface, has been developed to study electron attachment reaction at atmospheric pressure using nitrogen as the buffer gas. Based on the negative ion mobility spectra, the rate constants for electron attachment to tetrachloromethane and chloroform were measured at ambient temperature as a function of the average electron energy in the range from 0.29 to 0.96 eV. The experimental results are in good agreement with the data reported in the literature. - Highlights: ► Photoemission electron attachment ion mobility spectrometry (PE-EA-IMS) was developed to study electron attachment reaction. ► The rate constants of electron attachment to CCl 4 and CHCl 3 were determined. ► The present experimental results are in good agreement with the previously reported data.

  1. Secondary recurrent miscarriage is associated with previous male birth.

    LENUS (Irish Health Repository)

    Ooi, Poh Veh

    2012-01-31

    Secondary recurrent miscarriage (RM) is defined as three or more consecutive pregnancy losses after delivery of a viable infant. Previous reports suggest that a firstborn male child is associated with less favourable subsequent reproductive potential, possibly due to maternal immunisation against male-specific minor histocompatibility antigens. In a retrospective cohort study of 85 cases of secondary RM we aimed to determine if secondary RM was associated with (i) gender of previous child, maternal age, or duration of miscarriage history, and (ii) increased risk of pregnancy complications. Fifty-three women (62.0%; 53\\/85) gave birth to a male child prior to RM compared to 32 (38.0%; 32\\/85) who gave birth to a female child (p=0.002). The majority (91.7%; 78\\/85) had uncomplicated, term deliveries and normal birth weight neonates, with one quarter of the women previously delivered by Caesarean section. All had routine RM investigations and 19.0% (16\\/85) had an abnormal result. Fifty-seven women conceived again and 33.3% (19\\/57) miscarried, but there was no significant difference in failure rates between those with a previous male or female child (13\\/32 vs. 6\\/25, p=0.2). When patients with abnormal results were excluded, or when women with only one previous child were considered, there was still no difference in these rates. A previous male birth may be associated with an increased risk of secondary RM but numbers preclude concluding whether this increases recurrence risk. The suggested association with previous male birth provides a basis for further investigations at a molecular level.

  2. Secondary recurrent miscarriage is associated with previous male birth.

    LENUS (Irish Health Repository)

    Ooi, Poh Veh

    2011-01-01

    Secondary recurrent miscarriage (RM) is defined as three or more consecutive pregnancy losses after delivery of a viable infant. Previous reports suggest that a firstborn male child is associated with less favourable subsequent reproductive potential, possibly due to maternal immunisation against male-specific minor histocompatibility antigens. In a retrospective cohort study of 85 cases of secondary RM we aimed to determine if secondary RM was associated with (i) gender of previous child, maternal age, or duration of miscarriage history, and (ii) increased risk of pregnancy complications. Fifty-three women (62.0%; 53\\/85) gave birth to a male child prior to RM compared to 32 (38.0%; 32\\/85) who gave birth to a female child (p=0.002). The majority (91.7%; 78\\/85) had uncomplicated, term deliveries and normal birth weight neonates, with one quarter of the women previously delivered by Caesarean section. All had routine RM investigations and 19.0% (16\\/85) had an abnormal result. Fifty-seven women conceived again and 33.3% (19\\/57) miscarried, but there was no significant difference in failure rates between those with a previous male or female child (13\\/32 vs. 6\\/25, p=0.2). When patients with abnormal results were excluded, or when women with only one previous child were considered, there was still no difference in these rates. A previous male birth may be associated with an increased risk of secondary RM but numbers preclude concluding whether this increases recurrence risk. The suggested association with previous male birth provides a basis for further investigations at a molecular level.

  3. National Skills Standards Development Program: Organization and Operation of Technical Committees To Develop National Skill Standards for Competency in the Electronics Industry. The Third Party Summative Evaluation of the Electronic Industries Foundation Project. Phase I & II. Final Report.

    Science.gov (United States)

    Losh, Charles

    The Electronics Industries Foundation was awarded a project to develop national entry-level standards and a certification system. Ten specialties were included: automotive electronics, avionics, biomedical electronics, business machines, consumer products electronics, general electronics, industrial electronics, instrumentation, microcomputer, and…

  4. Montreal Accord on Patient-Reported Outcomes (PROs) use series - Paper 8: patient-reported outcomes in electronic health records can inform clinical and policy decisions.

    Science.gov (United States)

    Ahmed, Sara; Ware, Patrick; Gardner, William; Witter, James; Bingham, Clifton O; Kairy, Dahlia; Bartlett, Susan J

    2017-09-01

    Given that the goal of health care systems is to improve and maintain the health of the populations they serve, the indicators of performance must include outcomes that are meaningful to patients. The growth of health technologies provides an unprecedented opportunity to integrate the patient voice into clinical care by linking electronic health records (EHRs) to patient-reported outcome (PRO) data collection. However, PRO data must be relevant, meaningful, and actionable for those who will have to invest the time and effort to collect it. In this study, we highlight opportunities to integrate PRO data collection into EHRs. We consider how stakeholder perspectives should influence the selection of PROs and ways to enhance engagement in and commitment to PRO implementation. We propose a research and policy agenda to address unanswered questions and facilitate the widespread adoption of PRO data collection into EHRs. Building a learning health care system that gathers PRO data in ways that can inform individual patient care, quality improvement, and comparative effectiveness research has the potential to accelerate the application of new evidence and knowledge to patient care. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Previous Experience a Model of Practice UNAE

    Directory of Open Access Journals (Sweden)

    Ormary Barberi Ruiz

    2017-02-01

    Full Text Available The statements presented in this article represents a preliminary version of the proposed model of pre-professional practices (PPP of the National University of Education (UNAE of Ecuador, an urgent institutional necessity is revealed in the descriptive analyzes conducted from technical support - administrative (reports, interviews, testimonials, pedagogical foundations of UNAE (curricular directionality, transverse axes in practice, career plan, approach and diagnostic examination as subject nature of the pre professional practice and the demand of socio educational contexts where the practices have been emerging to resize them. By relating these elements allowed conceiving the modeling of the processes of the pre-professional practices for the development of professional skills of future teachers through four components: contextual projective, implementation (tutoring, accompaniment (teaching couple and monitoring (meetings at the beginning, during and end of practice. The initial training of teachers is inherent to teaching (academic and professional training, research and links with the community, these are fundamental pillars of Ecuadorian higher education.

  6. Pulsed WIP electron gun. Fabrication phase 1 x 40 cm and 1 x 70 cm cooled WIP electron gun. Final report, March 1979-December 1980

    International Nuclear Information System (INIS)

    Wakalopulos, G.

    1980-01-01

    An electron gun capable of long-run operation at 10 KHz and 1 A/cm 2 has been fabricated and tested. Pulse widths of 200 to 600 nsec and a total life of greater than 10 7 shots have been demonstrated. During the acceptance tests, the electron gun was operated at a total average power of 20 KW for 30 minutes. This basically satisfied the contract requirements. To establish some upper limit of the gun's capability, the device was operated at a repetition rate of 3.5 KHz at a total average power of 54.5 KW for greater than 10 minutes. During these tests, no high voltage breakdown occurred after the device was processed. The beam uniformity at high repetition rates is +-10% and the efficiency is 50%

  7. The SPRITE and POS-SPRITE user report: An extensible calculation of particle, positron and electron implantation in solids

    International Nuclear Information System (INIS)

    Ritley, K.A.; Ghosh, V.J.; Lynn, K.G.; McKewown, M.; Welch, D.O.

    1997-01-01

    SPRITE (Simulation of Particle Reemission, Implantation and Transmission--Extensible) is a Fortran computer program designed to model the transport of a stream of energetic particles as they scatter through a solid or multilayer. SPRITE is intended to be a user-friendly and easily-extensible engine for performing basic transport calculations, and SPRITE incorporates such physics as is required to simulate the transport process, but specifically omits the details of the scattering mechanisms. PSPRITE is a Fortran computer program, built around the SPRITE transport engine and incorporating physical information necessary for modeling the implantation and thermalization of a stream of positrons or electrons with a solid. This document is intended to be the primary source of information and the only operations manual for SPRITE and the POS-SPRITE family of programs. This information includes the mode of operation of SPRITE, the format of the required and optional file types, as well as information about the output and results of the calculation. Information about installing and running these programs on a variety of computer systems will not be addressed in this report. Such information is rapidly expanding as these programs are adapted to run on different platforms, and thus the user can expect such information to be contained with the source code distribution set. Detailed information about the calculations of the structure of the POS-SPRITE programs are provided in this report, but detailed benchmark comparisons between the output of these calculations and experimental data are an active topic of research, and they refer the reader to the published literature for this information

  8. Analytic turnaround time study for integrated reporting of pathology results on electronic medical records using the Illuminate system

    Directory of Open Access Journals (Sweden)

    Tawfik O

    2016-09-01

    Full Text Available Timely pathology results are critical for appropriate diagnosis and management of patients. Yet workflows in laboratories remain ad hoc and involve accessing multiple systems with no direct linkage between patient history and prior or pending pathology records for the case being analyzed. A major hindrance in timely reporting of pathology results is the need to incorporate/interface with multiple electronic health records (EHRs. We evaluated the Illuminate PatientView software (Illuminate integration into pathologist's workflow. Illuminate is a search engine architecture that has a repository of textual information from many hospital systems. Our goal was to develop a comprehensive, user friendly patient summary display to integrate the current fractionated subspecialty specific systems. An analytical time study noting changes in turnaround time (TAT before and after Illuminate implementation was recorded for reviewers, including pathologists, residents and fellows. Reviewers' TAT for 359 cases was recorded (200 cases before and 159 after implementation. The impact of implementing Illuminate on transcriptionists’ workflow was also studied. Average TAT to retrieve EHRs prior to Illuminate was 5:32 min (range 1:35-10:50. That time was significantly reduced to 35 seconds (range 10 sec-1:10 min using Illuminate. Reviewers were very pleased with the ease in accessing information and in eliminating the draft paper documents of the pathology reports, eliminating up to 65 min/day (25-65 min by transcriptionists matching requisition with paperwork. Utilizing Illuminate improved workflow, decreased TAT and minimized cost. Patient care can be improved through a comprehensive patient management system that facilitates communications between isolated information systems.

  9. Final Scientific/Technical Report: Electronics for Large Superconducting Tunnel Junction Detector Arrays for Synchrotron Soft X-ray Research

    Energy Technology Data Exchange (ETDEWEB)

    Warburton, William K

    2009-03-06

    Superconducting tunnel junction (STJ) detectors offer a an approach to detecting soft x-rays with energy resolutions 4-5 times better and at rates 10 faster than traditions semiconductor detectors. To make such detectors feasible, however, then need to be deployed in large arrays of order 1000 detectors, which in turn implies that their processing electronics must be compact, fully computer controlled, and low cost per channel while still delivering ultra-low noise performance so as to not degrade the STJ's performance. We report on our progress in designing a compact, low cost preamplifier intended for this application. In particular, we were able to produce a prototype preamplifier of 2 sq-cm area and a parts cost of less than $30 that matched the energy resolution of the best conventional system to date and demonstrated its ability to acquire an STJ I-V curve under computer control, the critical step for determining and setting the detectors' operating points under software control.

  10. Special report. Update on EAS (electronic article surveillance) systems: protecting against patient wandering, infant abduction, property theft.

    Science.gov (United States)

    1993-10-01

    Concern about wandering patients and infant abduction on the part of hospitals has sparked renewed interest in Electronic Article Surveillance (EAS) systems. Such systems had their origins in department stores and libraries where they are almost universally used. They also have applications in hospitals for preventing the theft of supplies and equipment. A number of companies provide EAS products for the health care field. How do you select the system that is best for your needs? "Talk to users. Pick out a number of profit and non-profit hospitals to get their views," advises Ted Algaier, vice president, marketing and sales, Innovative Control Systems, Inc., Waukesha, WI. "Examine the history of the company or vendor to determine if it understands the health care market and find out if the product really works." In this report, we'll review a number of EAS systems currently on the market, and present information on how they work, how effective they are, and costs involved. Also included are comments from users who have installed such systems.

  11. Application of NCRP REPORT No.151 for evaluating the radiation level at the ambience of megavoltage medical electron linear accelerator treatment room

    International Nuclear Information System (INIS)

    Yang Haiyou; Yu Shui

    2011-01-01

    Objective: The estimation model,on radiation level at the ambience of medical electron linear accelerator treatment rooms, is derived on the basis of NCRP REPORT No.151, which presents the calculation model of shielding design about barrier thicknesses of megavoltage medical electron linear accelerator treatment rooms. Methods: The estimation model comes from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities , which presents the calculation model of shielding design about megavoltage medical electron linear accelerator treatment rooms, and the dose rate at isocenter replaces the workload, and the occupancy factor and the use factor are forsaken, then the converse deduction is done according to barrier thicknesses of shielding materials. Ultimately, the estimation model, on radiation level at the ambience of medical electron linear accelerator treatment rooms, is derived. Results: It can be regarded as a systematic estimation model for calculating the radiation level at the ambience of medical electron linear accelerator treatment room. Conclusion: The estimation model has certain practical value to evaluate the radiation level at the ambience of medical electron linear accelerator treatment room. (authors)

  12. Electron beam production by a plasma focus

    International Nuclear Information System (INIS)

    Smith, J.R.; Luo, C.M.; Schneider, R.F.; Rhee, M.J.

    1984-01-01

    Operation of a plasma focus as a Compact Pulsed Accelerator (CPA) for ions has been previously reported. The CPA consists of: (1) a 15 μF, 3 kJ capacitor, (2) a triggered spark gap, (3) a coaxial transmission line, and (4) a Mather geometry plasma gun. Recently the authors have investigated application of the CPA as an accelerator for electrons. In the previously reported work using the standard Mather plasma gun geometry, ions were accelerated away from the plasma gun and were therefore conveniently extracted for analysis, but electrons were directed into the hollow anode where extraction is blocked by the coaxial transmission line. For investigation of accelerated electrons a new plasma gun design which allows extraction of electrons has been developed. Details of the new plasma gun design and further results of beam diagnostics are discussed

  13. FY 2005 Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery Program

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, M

    2005-11-22

    appropriate technical targets for systems, subsystems, and component research and development activities; (2) Develop and validate individual subsystems and components, including electric motors, emission control devices, battery systems, power electronics, accessories, and devices to reduce parasitic losses; and (3) Determine how well the components and subsystems work together in a vehicle environment or as a complete propulsion system and whether the efficiency and performance targets at the vehicle level have been achieved. The research performed under the Vehicle Systems subprogram will help remove technical and cost barriers to enable technology for use in such advanced vehicles as hybrid and fuel-cell-powered automobiles that meet the goals of the FreedomCAR Program. A key element in making hybrid electric vehicles practical is providing an affordable electric traction drive system. This will require attaining weight, volume, and cost targets for the power electronics and electrical machines subsystems of the traction drive system. Areas of development include: (1) Novel traction motor designs that result in increased power density and lower cost; (2) Inverter technologies involving new topologies to achieve higher efficiency and the ability to accommodate higher-temperature environments; (3) Converter concepts that employ means of reducing the component count and integrating functionality to decrease size, weight, and cost; (4) More effective thermal control and packaging technologies; and (5) Integrated motor/inverter concepts. The Oak Ridge National Laboratory's (ORNL's) Power Electronics and Electric Machinery Research Center conducts fundamental research, evaluates hardware, and assists in the technical direction of the DOE Office of FreedomCAR and Vehicle Technologies Program, Power Electronics and Electric Machinery Program. In this role, ORNL serves on the FreedomCAR Electrical and Electronics Technical Team, evaluates proposals for DOE, and lends its

  14. Excitation and ionization of ions by electron impact. Technical progress report, September 1, 1974--May 31, 1975

    International Nuclear Information System (INIS)

    Feeney, R.K.; Divine, T.F.; Kovac, R.M.; McPherson, D.; Sayle, W.E.

    1975-01-01

    This effort is devoted to experimental measurements of electron impact excitation and ionization cross sections of ions. The cross sections of interest are those of importance in the diagnostics of CTR plasmas. Current tasks include: the completion of absolute measurements of the electron impact cross sections for Rb + , Cs + , and Tl + ions; and determination of the absolute electron impact excitation cross sections for selected transitions in Li + and other He-, Li-, and Be-like ions. (U.S.)

  15. Supporting information retrieval from electronic health records: A report of University of Michigan's nine-year experience in developing and using the Electronic Medical Record Search Engine (EMERSE).

    Science.gov (United States)

    Hanauer, David A; Mei, Qiaozhu; Law, James; Khanna, Ritu; Zheng, Kai

    2015-06-01

    This paper describes the University of Michigan's nine-year experience in developing and using a full-text search engine designed to facilitate information retrieval (IR) from narrative documents stored in electronic health records (EHRs). The system, called the Electronic Medical Record Search Engine (EMERSE), functions similar to Google but is equipped with special functionalities for handling challenges unique to retrieving information from medical text. Key features that distinguish EMERSE from general-purpose search engines are discussed, with an emphasis on functions crucial to (1) improving medical IR performance and (2) assuring search quality and results consistency regardless of users' medical background, stage of training, or level of technical expertise. Since its initial deployment, EMERSE has been enthusiastically embraced by clinicians, administrators, and clinical and translational researchers. To date, the system has been used in supporting more than 750 research projects yielding 80 peer-reviewed publications. In several evaluation studies, EMERSE demonstrated very high levels of sensitivity and specificity in addition to greatly improved chart review efficiency. Increased availability of electronic data in healthcare does not automatically warrant increased availability of information. The success of EMERSE at our institution illustrates that free-text EHR search engines can be a valuable tool to help practitioners and researchers retrieve information from EHRs more effectively and efficiently, enabling critical tasks such as patient case synthesis and research data abstraction. EMERSE, available free of charge for academic use, represents a state-of-the-art medical IR tool with proven effectiveness and user acceptance. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Squamous cell carcinoma arising in previously burned or irradiated skin

    International Nuclear Information System (INIS)

    Edwards, M.J.; Hirsch, R.M.; Broadwater, J.R.; Netscher, D.T.; Ames, F.C.

    1989-01-01

    Squamous cell carcinoma (SCC) arising in previously burned or irradiated skin was reviewed in 66 patients treated between 1944 and 1986. Healing of the initial injury was complicated in 70% of patients. Mean interval from initial injury to diagnosis of SCC was 37 years. The overwhelming majority of patients presented with a chronic intractable ulcer in previously injured skin. The regional relapse rate after surgical excision was very high, 58% of all patients. Predominant patterns of recurrence were in local skin and regional lymph nodes (93% of recurrences). Survival rates at 5, 10, and 20 years were 52%, 34%, and 23%, respectively. Five-year survival rates in previously burned and irradiated patients were not significantly different (53% and 50%, respectively). This review, one of the largest reported series, better defines SCC arising in previously burned or irradiated skin as a locally aggressive disease that is distinct from SCC arising in sunlight-damaged skin. An increased awareness of the significance of chronic ulceration in scar tissue may allow earlier diagnosis. Regional disease control and survival depend on surgical resection of all known disease and may require radical lymph node dissection or amputation

  17. Interaction of slow electrons with high-pressure gases ('Quasi-liquids'): synthesis of our knowledge on slow electron-molecule interactions. Progress report

    International Nuclear Information System (INIS)

    McCorkle, D.L.; Christophorou, L.G.

    1985-01-01

    A crucial step in our efforts to develop not only a coherent picture of radiation interaction with matter, but also to understand radiation effects and mechanisms, as well as the effects of chemical pollutants and toxic compounds, is to relate the often abundant knowledge on isolated molecules (low pressure gases) to that on liquids or solids. To understand the roles of the physical and chemical properties of molecules in biological reactions, we must know how these isolated-molecule properties change as molecules are embedded in gradually thicker and thicker (denser and denser) gaseous and, finally, liquid environments. The work initiated by us both at the Physics Department of The University of Tennessee and at the Oak Ridge National Laboratory addresses itself to this question. At both places, high pressure (40 to approx.8000 kPa) electron swarm experiments are currently in operation yielding information as to the effects of the density and nature of the environment on fundamental electron-molecule interaction processes at densities intermediate to those corresponding to low pressure gases and liquids, and the gradual transition from isolated molecule to condensed phase behavior

  18. The contribution of electronically excited states to the radiation chemistry of organic systems: Progress report, June 30, 1985-December 30, 1987

    International Nuclear Information System (INIS)

    Lipsky, S.

    1987-01-01

    Research progress is reported on the following topics: effects of electron scavengers on the escape probabilities of geminate ion pairs, mechanism of liquid scintillation counter, photoionization of solutes in nonpolar liquids, kinetics of recombination of geminate ion pairs, and fluorescence of saturated hydrocarbons

  19. Clinical Trial Electronic Portals for Expedited Safety Reporting: Recommendations from the Clinical Trials Transformation Initiative Investigational New Drug Safety Advancement Project.

    Science.gov (United States)

    Perez, Raymond P; Finnigan, Shanda; Patel, Krupa; Whitney, Shanell; Forrest, Annemarie

    2016-12-15

    Use of electronic clinical trial portals has increased in recent years to assist with sponsor-investigator communication, safety reporting, and clinical trial management. Electronic portals can help reduce time and costs associated with processing paperwork and add security measures; however, there is a lack of information on clinical trial investigative staff's perceived challenges and benefits of using portals. The Clinical Trials Transformation Initiative (CTTI) sought to (1) identify challenges to investigator receipt and management of investigational new drug (IND) safety reports at oncologic investigative sites and coordinating centers and (2) facilitate adoption of best practices for communicating and managing IND safety reports using electronic portals. CTTI, a public-private partnership to improve the conduct of clinical trials, distributed surveys and conducted interviews in an opinion-gathering effort to record investigator and research staff views on electronic portals in the context of the new safety reporting requirements described in the US Food and Drug Administration's final rule (Code of Federal Regulations Title 21 Section 312). The project focused on receipt, management, and review of safety reports as opposed to the reporting of adverse events. The top challenge investigators and staff identified in using individual sponsor portals was remembering several complex individual passwords to access each site. Also, certain tasks are time-consuming (eg, downloading reports) due to slow sites or difficulties associated with particular operating systems or software. To improve user experiences, respondents suggested that portals function independently of browsers and operating systems, have intuitive interfaces with easy navigation, and incorporate additional features that would allow users to filter, search, and batch safety reports. Results indicate that an ideal system for sharing expedited IND safety information is through a central portal used by

  20. FY2010 Oak Ridge National Laboratory Annual Progress Report for the Power Electronics and Electric Machinery Program

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Mitchell [ORNL

    2010-10-01

    The U.S. Department of Energy (DOE) and the U.S. Council for Automotive Research (composed of automakers Ford, General Motors, and Chrysler) announced in January 2002 a new cooperative research effort. Known as FreedomCAR (derived from ''Freedom'' and ''Cooperative Automotive Research''), it represents DOE's commitment to developing public-private partnerships to fund high risk, high payoff research into advanced automotive technologies. Efficient fuel cell technology, which uses hydrogen to power automobiles without air pollution, is a very promising pathway to achieve the ultimate vision. The new partnership replaces and builds upon the Partnership for a New Generation of Vehicles initiative that ran from 1993 through 2001. The Oak Ridge National Laboratory's (ORNL's) Advanced Power Electronics and Electric Machines (APEEM) subprogram within the DOE Vehicle Technologies Program (VTP) provides support and guidance for many cutting-edge automotive technologies now under development. Research is focused on developing revolutionary new power electronics (PE) and electric motor technologies that will leapfrog current on-the-road technologies. The research and development (R&D) is also aimed at achieving a greater understanding of and improvements in the way the various new components of tomorrow's automobiles will function as a unified system to improve fuel efficiency. In supporting the development of advanced vehicle propulsion systems, the APEEM subprogram has enabled the development of technologies that will significantly improve efficiency, costs, and fuel economy. The APEEM subprogram supports the efforts of the FreedomCAR and Fuel Partnership through a three phase approach intended to: (1) identify overall propulsion and vehicle related needs by analyzing programmatic goals and reviewing industry's recommendations and requirements and then develop the appropriate technical targets for systems

  1. A Prototypical First-Generation Electronic Cigarette Does Not Reduce Reports of Tobacco Urges or Withdrawal Symptoms among Cigarette Smokers

    Directory of Open Access Journals (Sweden)

    Arit M. Harvanko

    2017-01-01

    Full Text Available It is unknown whether first-generation electronic cigarettes reduce smoking urges and withdrawal symptoms following a 24 h deprivation period. This study tested whether a first-generation electronic cigarette reduces smoking urges and withdrawal symptoms in cigarette smokers. Following 24 h of tobacco deprivation, using a within-subjects design, eight nontreatment seeking tobacco cigarette smokers (3 females administered 10 puffs from a conventional cigarette or a first-generation electronic cigarette containing liquid with 0, 8 or 16 mg/ml nicotine. Conventional cigarettes ameliorated smoking urges and electronic cigarettes did not, regardless of nicotine concentration. First-generation electronic cigarettes may not effectively substitute for conventional cigarettes in reducing smoking urges, regardless of nicotine concentration.

  2. Excitation and ionization of ions by electron impact. Technical progress report, September 1, 1977--May 31, 1978

    International Nuclear Information System (INIS)

    Feeney, R.K.; Hughes, D.W.; Hoak, G.B.; Priester, D.C.; Sayle, W.E.

    1978-01-01

    This effort is devoted to the measurement of electron impact collision processes of importance in controlled thermonuclear research. Electron impact, single and multiple ionization of ions and charge exchange processes are being studied. A program to develop ion sources for future collision experiments is also included. Preliminary measurements of the electron impact triple and quadruple ionization cross sections of Pb + ions have been completed. Measurements were made over the range of electron energies from the respective thresholds to 1000 eV. A hollow-cathode discharge type ion source and associated m/e analyzer has been constructed. A charge exchange apparatus suitable for the measurement of electron capture and stripping cross sections of selected singly charged metallic ions and neutrals is being designed. This apparatus will be employed with the hollow-cathode ion source module. A Penning Ion Gauge (PIG) type ion source of multiply charge ions is in continuing development

  3. Evaluating health information technology: provider satisfaction with an HIV-specific, electronic clinical management and reporting system.

    Science.gov (United States)

    Magnus, Manya; Herwehe, Jane; Andrews, Laura; Gibson, Laura; Daigrepont, Nathan; De Leon, Jordana M; Hyslop, Newton E; Styron, Steven; Wilcox, Ronald; Kaiser, Michael; Butler, Michael K

    2009-02-01

    Health information technology (HIT) offers the potential to improve care for persons living with HIV. Provider satisfaction with HIT is essential to realize benefits, yet its evaluation presents challenges. An HIV-specific, electronic clinical management and reporting system was implemented in Louisiana's eight HIV clinics, serving over 7500. A serial cross-sectional survey was administered at three points between April 2002 and July 2005; qualitative methods were used to augment quantitative. Multivariable methods were used to characterize provider satisfaction. The majority of the sample (n = 196; T1 = 105; T2 = 46; T3 = 45) was female (80.0%), between ages of 25 and 50 years (68.3%), frequent providers at that clinic (53.7% more than 4 days per week), and had been at the same clinic for a year or more (85.0%). Improvements in satisfaction were observed in patient tracking ( p 0.05), current viral load decreased at each time point (mean 4.0 [SD 5.6], 2.9 [2.5], 1.8 [2.6], p = 0.08], current antiretroviral status decreased at each time point (mean 3.9 [SD 4.7], 2.9 [3.7], 1.5 [1.1], p < 0.04), history of antiretroviral use decreased at each time point (mean 15.1 [SD 21.9], 6.0 [5.4], 5.4 [7.2], p < 0.04]. Time savings were realized, averaging 16.1 minutes per visit ( p < 0.04). Providers were satisfied with HIT in multiple domains, and significant time savings were realized.

  4. Final report to US Department of Energy: Cyclotron autoresonance accelerator for electron beam dry scrubbing of flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, J.L.

    2001-05-25

    Several designs have been built and operated of microwave cyclotron autoresonance accelerators (CARA's) with electron beam parameters suitable for remediation of pollutants in flue gas emissions from coal-burning power plants. CARA designs have also been developed with a TW-level 10.6 micron laser driver for electron acceleration from 50 to 100 MeV, and with UHF drivers for proton acceleration to over 500 MeV. Dose requirements for reducing SO2, NOx, and particulates in flue gas emissions to acceptable levels have been surveyed, and used to optimize the design of an electron beam source to deliver this dose.

  5. Near-infrared branding efficiently correlates light and electron microscopy.

    Science.gov (United States)

    Bishop, Derron; Nikić, Ivana; Brinkoetter, Mary; Knecht, Sharmon; Potz, Stephanie; Kerschensteiner, Martin; Misgeld, Thomas

    2011-06-05

    The correlation of light and electron microscopy of complex tissues remains a major challenge. Here we report near-infrared branding (NIRB), which facilitates such correlation by using a pulsed, near-infrared laser to create defined fiducial marks in three dimensions in fixed tissue. As these marks are fluorescent and can be photo-oxidized to generate electron contrast, they can guide re-identification of previously imaged structures as small as dendritic spines by electron microscopy.

  6. Absolute experimental cross sections for the ionization of singly charged barium ions by electron impact: Technical summary report

    International Nuclear Information System (INIS)

    Feeney, R.K.; Hooper, J.W.

    1971-01-01

    The absolute cross sections for the single ionization of Ba + ions by electron impact have been measured as a function of incident electron energy over the electron energy range from below threshold (10.001 eV) to approximately 1000 eV. It is found that the cross section increases from 1.94 x 10 -16 cm 2 to 3.76 x 10 -16 cm 2 between 15.5 and 18 eV actual incident electron energy. This rapid rise is interpreted as the onset of autoionization. Some evidence of structure occurring near the peak of the cross section curve such as found in the isoelectronic system of Cs is observed, but the relative magnitude of the apparent structure is of the same order as the 90% random error confidence limits and thus cannot conclusively be regarded as being present. 56 refs., 16 figs., 7 tabs

  7. Slow electron motion in condensed matter: Final progress report for period January 1, 1984-December 31, 1986

    International Nuclear Information System (INIS)

    Fano, U.

    1987-02-01

    A summary is given for theoretical procedures that describe and evaluate the penetration, degradation and diffusion of slow electrons in condensed matter with characteristics relevant to biological systems. 5 refs

  8. Nuclear structure studies by the scattering of medium-energy electrons: Progress report, September 1, 1986-June 30, 1987

    International Nuclear Information System (INIS)

    Teterson, G.A.; Hicks, R.S.; Dubach, J.F.; Miskimen, R.A.

    1987-06-01

    This paper discusses the experimental electron scattering studies at SLAC and Bates Accelerator Center. Some theoretical work on nucleon-nucleon interactions, electromagnetic interactions, weak interactions and nuclear structure are also discussed

  9. Activity of the Service for maintenance of the electronic equipment of the RA reactor in 1976, report - Annex IV

    International Nuclear Information System (INIS)

    Milosevic, M.

    1976-01-01

    Within the organizational structure of the RA reactor staff, the Service for instrumentation maintenance has the following tasks: maintenance of the existing electronic equipment; participating in experiments planning and preparation of electronic equipment; purchasing new equipment, spare parts and components; construction of new equipment for internal needs; implementation of new equipment. Basic instrumentation of the reactor facility includes: control and protection system, and dosimetry system [sr

  10. [Electron transfer, ionization, and excitation in atomic collisions]. Final technical report, June 15, 1986 - June 14, 1998

    International Nuclear Information System (INIS)

    1998-01-01

    The research on theoretical atomic collisions that was funded at The Pennsylvania State University's Wilkes-Barre Campus by DOE from 1986 to 1998 was carried out by Winger from 1986 to 1989 and by Winter and Alston from 1989 to 1998. The fundamental processes of electron transfer, ionization, and excitation in ion-ion, ion-atom, and, more recently, ion-molecule collisions were addressed. These collision processes were treated in the context of simple one-electron, quasi-one-electron, or two-electron systems in order to provide unambiguous results and reveal more clearly the collisional mechanisms. Winter's work generally focused on the intermediate projectile-energy range corresponding to proton energies from about ten to a few hundred keV. In this velocity-matching energy range, the electron-transfer cross section reaches a peak, and many states, including electron-transfer and ionization states, contribute to the overall electron-cloud distribution and transition probabilities; a large number of states are coupled, and therefore perturbative approaches are generally inappropriate. These coupled-state calculations were sometimes also extended to higher energies to join with perturbative results. Alston concentrated on intermediate-energy asymmetric collision systems, for which coupling with the projectile is weaker, but many target states are included, and on high energies (MeV energies). Thus, while perturbation theory for electron transfer is valid, it is not adequate to first order. The studies by Winter and Alston described were often done in parallel. Alston also developed formal perturbative approaches not tied to any particular system. Materials studied included He + , Li 2+ , Be 3+ , B 4+ , C 5+ , and the H + + Na system

  11. Relaxation mechanism of the hydrated electron.

    Science.gov (United States)

    Elkins, Madeline H; Williams, Holly L; Shreve, Alexander T; Neumark, Daniel M

    2013-12-20

    The relaxation dynamics of the photoexcited hydrated electron have been subject to conflicting interpretations. Here, we report time-resolved photoelectron spectra of hydrated electrons in a liquid microjet with the aim of clarifying ambiguities from previous experiments. A sequence of three ultrashort laser pulses (~100 femtosecond duration) successively created hydrated electrons by charge-transfer-to-solvent excitation of dissolved anions, electronically excited these electrons via the s→p transition, and then ejected them into vacuum. Two distinct transient signals were observed. One was assigned to the initially excited p-state with a lifetime of ~75 femtoseconds, and the other, with a lifetime of ~400 femtoseconds, was attributed to s-state electrons just after internal conversion in a nonequilibrated solvent environment. These assignments support the nonadiabatic relaxation model.

  12. Electron-electron Bremsstrahlung for bound target electrons

    International Nuclear Information System (INIS)

    Haug, E.

    2008-01-01

    For the process of electron-electron (e-e) Bremsstrahlung the momentum and energy distributions of the recoiling electrons are calculated in the laboratory frame. In order to get the differential cross section and the photon spectrum for target electrons which are bound to an atom, these formulae are multiplied by the incoherent scattering function and numerically integrated over the recoil energy. The effect of atomic binding is most pronounced at low energies of the incident electrons and for target atoms of high atomic numbers. The results are compared to those of previous calculations. (authors)

  13. Drug Dosing in Patients with Renal Insufficiency in a Hospital Setting using Electronic Prescribing and Automated Reporting of Estimated Glomerular Filtration Rate

    DEFF Research Database (Denmark)

    Nielsen, Anita L.; Henriksen, Daniel Pilsgaard; Marinakis, Christianna

    2014-01-01

    In patients with impaired renal function, drug dose adjustment is often required. Non-adherence to clinical prescribing recommendations may result in severe adverse events. In previous studies, the prevalence rate of non-adherence to recommended dosing has been reported to be 19-67%. Using the cl...... decision support systems should be explored. This article is protected by copyright. All rights reserved....

  14. Effects of Electronic Cigarette Liquid Nicotine Concentration on Plasma Nicotine and Puff Topography in Tobacco Cigarette Smokers: A Preliminary Report.

    Science.gov (United States)

    Lopez, Alexa A; Hiler, Marzena M; Soule, Eric K; Ramôa, Carolina P; Karaoghlanian, Nareg V; Lipato, Thokozeni; Breland, Alison B; Shihadeh, Alan L; Eissenberg, Thomas

    2016-05-01

    Electronic cigarettes (ECIGs) aerosolize a liquid that usually contains propylene glycol and/or vegetable glycerin, flavorants, and the dependence-producing drug nicotine in various concentrations. This study examined the extent to which ECIG liquid nicotine concentration is related to user plasma nicotine concentration in ECIG-naïve tobacco cigarette smokers. Sixteen ECIG-naïve cigarette smokers completed four laboratory sessions that differed by the nicotine concentration of the liquid (0, 8, 18, or 36 mg/ml) that was placed into a 1.5 Ohm, dual coil "cartomizer" powered by a 3.3V battery. In each session, participants completed two, 10-puff ECIG use bouts with a 30-second inter-puff interval; bouts were separated by 60 minutes. Venous blood was sampled before and after bouts for later analysis of plasma nicotine concentration; puff duration, volume, and average flow rate were measured during each bout. In bout 1, relative to the 0mg/ml nicotine condition (mean = 3.8 ng/ml, SD = 3.3), plasma nicotine concentration increased significantly immediately after the bout for the 8 (mean = 8.8 ng/ml, SD = 6.3), 18 (mean = 13.2 ng/ml, SD = 13.2), and 36 mg/ml (mean = 17.0 ng/ml, SD = 17.9) liquid concentration. A similar pattern was observed after bout 2. Average puff duration in the 36 mg/ml condition was significantly shorter compared to the 0mg/ml nicotine condition. Puff volume increased during the second bout for 8 and 18 mg/ml conditions. For a given ECIG device, nicotine delivery may be directly related to liquid concentration. ECIG-naïve cigarette smokers can, from their first use bout, attain cigarette-like nicotine delivery profiles with some currently available ECIG products. Liquid nicotine concentration can influence plasma nicotine concentration in ECIG-naïve cigarette smokers, and, at some concentrations, the nicotine delivery profile of a 3.3V ECIG with a dual coil, 1.5-Ohm cartomizer approaches that of a combustible tobacco cigarette in this

  15. The Computer-based Health Evaluation Software (CHES: a software for electronic patient-reported outcome monitoring

    Directory of Open Access Journals (Sweden)

    Holzner Bernhard

    2012-11-01

    Full Text Available Abstract Background Patient-reported Outcomes (PROs capturing e.g., quality of life, fatigue, depression, medication side-effects or disease symptoms, have become important outcome parameters in medical research and daily clinical practice. Electronic PRO data capture (ePRO with software packages to administer questionnaires, storing data, and presenting results has facilitated PRO assessment in hospital settings. Compared to conventional paper-pencil versions of PRO instruments, ePRO is more economical with regard to staff resources and time, and allows immediate presentation of results to the medical staff. The objective of our project was to develop software (CHES – Computer-based Health Evaluation System for ePRO in hospital settings and at home with a special focus on the presentation of individual patient’s results. Methods Following the Extreme Programming development approach architecture was not fixed up-front, but was done in close, continuous collaboration with software end users (medical staff, researchers and patients to meet their specific demands. Developed features include sophisticated, longitudinal charts linking patients’ PRO data to clinical characteristics and to PRO scores from reference populations, a web-interface for questionnaire administration, and a tool for convenient creating and editing of questionnaires. Results By 2012 CHES has been implemented at various institutions in Austria, Germany, Switzerland, and the UK and about 5000 patients participated in ePRO (with around 15000 assessments in total. Data entry is done by the patients themselves via tablet PCs with a study nurse or an intern approaching patients and supervising questionnaire completion. Discussion During the last decade several software packages for ePRO have emerged for different purposes. Whereas commercial products are available primarily for ePRO in clinical trials, academic projects have focused on data collection and presentation in daily

  16. Electronics and electronic systems

    CERN Document Server

    Olsen, George H

    1987-01-01

    Electronics and Electronic Systems explores the significant developments in the field of electronics and electronic devices. This book is organized into three parts encompassing 11 chapters that discuss the fundamental circuit theory and the principles of analog and digital electronics. This book deals first with the passive components of electronic systems, such as resistors, capacitors, and inductors. These topics are followed by a discussion on the analysis of electronic circuits, which involves three ways, namely, the actual circuit, graphical techniques, and rule of thumb. The remaining p

  17. Fundamental studies on electron-beam welding of heat-resistant superalloys for nuclear plants: Report 4. Mechanical properties of welded joints

    International Nuclear Information System (INIS)

    Susei, S.; Shimizu, S.; Aota, T.

    1982-04-01

    In this report, electron-beam (EB) welded joints and TIG welded joints of various superalloys to be used for nuclear plants, such as Hastelloy-type, Inconel-type and Incoloy-type, are systematically evaluated in terms of tensile properties, low-cycle fatigue properties at elevated temperatures, creep and creep-rupture properties. It was fully confirmed as conclusion that the EB welded joints are superior to the TIG welded ones in mechanical properties, especially at high temperature. In the evaluation of creep properties, ductility is one of the most important criteria to represent the resistance against fracture due to creep deformation, and this criterion is very useful in evaluating the properties of welded joints. Therefore, the more comparable to the base metal the electron beam welded joint becomes in terms of ductility, the more resistant is it against fracture. From this point of view, the electron beam welded joint is considerably superior to the TIG welded joint [fr

  18. Electronic plants

    Science.gov (United States)

    Stavrinidou, Eleni; Gabrielsson, Roger; Gomez, Eliot; Crispin, Xavier; Nilsson, Ove; Simon, Daniel T.; Berggren, Magnus

    2015-01-01

    The roots, stems, leaves, and vascular circuitry of higher plants are responsible for conveying the chemical signals that regulate growth and functions. From a certain perspective, these features are analogous to the contacts, interconnections, devices, and wires of discrete and integrated electronic circuits. Although many attempts have been made to augment plant function with electroactive materials, plants’ “circuitry” has never been directly merged with electronics. We report analog and digital organic electronic circuits and devices manufactured in living plants. The four key components of a circuit have been achieved using the xylem, leaves, veins, and signals of the plant as the template and integral part of the circuit elements and functions. With integrated and distributed electronics in plants, one can envisage a range of applications including precision recording and regulation of physiology, energy harvesting from photosynthesis, and alternatives to genetic modification for plant optimization. PMID:26702448

  19. Ultraviolet and electron-beam curing of printing inks. January 1980-August 1987 (Citations from World Surface Coatings Abstracts). Report for January 1980-August 1987

    International Nuclear Information System (INIS)

    1989-08-01

    This bibliography contains citations concerning methods, techniques, and applications for the ultraviolet and electron-beam curing of printing inks. Topics include ink compositions, curing methods and equipment, cured-ink evaluations, screen printing inks, photoinitiators, and ink binders. The pollution and safety problems, and future trends of UV- and E-beam-cured printing inks are considered. Applications in screen printing on polyethylene or polypropylene bottles, and decorative printing of glass are also examined. (This updated bibliography contains 237 citations, 63 of which are new entries to the previous edition.)

  20. Simulation and measurement of the plasmaspheric electron content. Final report, 1 October 1974--30 September 1976

    International Nuclear Information System (INIS)

    Poletti-Liuzzi, D.A.; Yeh, K.C.; Liu, C.H.

    1976-09-01

    Two techniques are used to measure the plasmaspheric electron content. The Faraday effect, which is weighted by the Earth magnetic field, is insensitive to electrons in the plasmasphere. The differential group delay is equally sensitive to all electrons along the radio path. Therefore, by combining these techniques, the plasmaspheric content can be measured. However, the sensitivity of the techniques depend on the ionospheric parameters. Therefore, in order to obtain consistent results from the data, computer simulations investigating the sensitivity of the techniques to different ionospheric models are carried out and discussed. The equipment contribution and effects to the measurements are also investigated. Results of the measured plasmaspheric content from the ATS-6 data under normal geomagnetic conditions and during magnetic storms are presented. The possible causes of the observed behavior are also presented

  1. Two-electron oxidation of cobalt phthalocyanines by thionyl chloride: Implications for lithium/thionyl chloride batteries. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, P.A.; Lever, A.B.

    1989-10-20

    Cyclic voltammetry, DPV and electronic spectroscopy are used to study the reaction between thionyl chloride and cobalt phthalocyanine. SOCl2 reacts with (Co(I)Tn Pc(2-)) and Co(II)Tn Pc(2-) to give two-electron oxidized species. Implications for Li/SOCl2 batteries are discussed. Thionyl chloride also forms a mono SOCl2 adduct with Co(II)TnPc(2-). Driving forces (Delta E values) were calculated for CoTnPc comproportionation and CoTnPc + SOCl2 reactions. Rest potential measurements of a Li/SOCl2 cells show that addition of AlCl3 stabilizes the LiCl product as LiAlCl4. A catalytic two-electron mechanism is indicated for the reduction of thionyl chloride in a Li/SOCl2/(CoTnPc,C) battery.

  2. CRADA Final Report for CRADA No. ORNL99-0544, Interfacial Properties of Electron Beam Cured Composites

    Energy Technology Data Exchange (ETDEWEB)

    Janke, C.J.

    2005-10-17

    Electron beam (EB) curing is a technology that promises, in certain applications, to deliver lower cost and higher performance polymer matrix composite (PMC) structures compared to conventional thermal curing processes. PMCs enhance performance by making products lighter, stronger, more durable, and less energy demanding. They are essential in weight- and performance-dominated applications. Affordable PMCs can enhance US economic prosperity and national security. US industry expects rapid implementation of electron beam cured composites in aircraft and aerospace applications as satisfactory properties are demonstrated, and implementation in lower performance applications will likely follow thereafter. In fact, at this time and partly because of discoveries made in this project, field demonstrations are underway that may result in the first fielded applications of electron beam cured composites. Serious obstacles preventing the widespread use of electron beam cured PMCs in many applications are their relatively poor interfacial properties and resin toughness. The composite shear strength and resin toughness of electron beam cured carbon fiber reinforced epoxy composites were about 25% and 50% lower, respectively, than those of thermally cured composites of similar formulations. The essential purpose of this project was to improve the mechanical properties of electron beam cured, carbon fiber reinforced epoxy composites, with a specific focus on composite shear properties for high performance aerospace applications. Many partners, sponsors, and subcontractors participated in this project. There were four government sponsors from three federal agencies, with the US Department of Energy (DOE) being the principal sponsor. The project was executed by Oak Ridge National Laboratory (ORNL), NASA and Department of Defense (DOD) participants, eleven private CRADA partners, and two subcontractors. A list of key project contacts is provided in Appendix A. In order to properly

  3. Improved Electron Yield and Spin-Polarization from III-V Photocathodes via Bias Enhanced Carrier Drift: Final Report

    International Nuclear Information System (INIS)

    Mulhollan, Gregory A.

    2006-01-01

    In this DOE STTR program, Saxet Surface Science, with the Stanford Linear Accelerator Center as partner, designed, built and tested photocathode structures such that optimal drift-enhanced spin-polarization from GaAs based photoemitters was achieved with minimal bias supply requirements. The forward bias surface grid composition was optimized for maximum polarization and yield, together with other construction parameters including doping profile. This program has culminated in a cathode bias structure affording increased electron spin polarization when applied to III-V based photocathodes. The optimized bias structure has been incorporated into a cathode mounting and biasing design for use in a polarized electron gun.

  4. Status report on the 'Merging' of the Electron-Cloud Code POSINST with the 3-D Accelerator PIC CODE WARP

    International Nuclear Information System (INIS)

    Vay, J.-L.; Furman, M.A.; Azevedo, A.W.; Cohen, R.H.; Friedman, A.; Grote, D.P.; Stoltz, P.H.

    2004-01-01

    We have integrated the electron-cloud code POSINST [1] with WARP [2]--a 3-D parallel Particle-In-Cell accelerator code developed for Heavy Ion Inertial Fusion--so that the two can interoperate. Both codes are run in the same process, communicate through a Python interpreter (already used in WARP), and share certain key arrays (so far, particle positions and velocities). Currently, POSINST provides primary and secondary sources of electrons, beam bunch kicks, a particle mover, and diagnostics. WARP provides the field solvers and diagnostics. Secondary emission routines are provided by the Tech-X package CMEE

  5. Improving national surveillance of Lyme neuroborreliosis in Denmark through electronic reporting of specific antibody index testing from 2010 to 2012

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Espenhain, L; Mølbak, K

    2015-01-01

    Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer of labora......Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer...

  6. Electronics department

    International Nuclear Information System (INIS)

    1979-01-01

    This report summarizes the activities in 1978 of some of the groups within the Electronics Department. The work covered includes plant protection and operator studies, reliability techniques, application of nuclear techniques to mineral exploration, applied laser physics, computing and, lastly, research instrumentation. (author)

  7. High-Grade Leiomyosarcoma Arising in a Previously Replanted Limb

    Directory of Open Access Journals (Sweden)

    Tiffany J. Pan

    2015-01-01

    Full Text Available Sarcoma development has been associated with genetics, irradiation, viral infections, and immunodeficiency. Reports of sarcomas arising in the setting of prior trauma, as in burn scars or fracture sites, are rare. We report a case of a leiomyosarcoma arising in an arm that had previously been replanted at the level of the elbow joint following traumatic amputation when the patient was eight years old. He presented twenty-four years later with a 10.8 cm mass in the replanted arm located on the volar forearm. The tumor was completely resected and pathology examination showed a high-grade, subfascial spindle cell sarcoma diagnosed as a grade 3 leiomyosarcoma with stage pT2bNxMx. The patient underwent treatment with brachytherapy, reconstruction with a free flap, and subsequently chemotherapy. To the best of our knowledge, this is the first case report of leiomyosarcoma developing in a replanted extremity. Development of leiomyosarcoma in this case could be related to revascularization, scar formation, or chronic injury after replantation. The patient remains healthy without signs of recurrence at three-year follow-up.

  8. Associations Between Personality Traits and Adherence to Antidepressants Assessed Through Self-Report, Electronic Monitoring, and Pharmacy Dispensing Data: A Pilot Study.

    Science.gov (United States)

    Wouters, Hans; Amin, Darya F H; Taxis, Katja; Heerdink, Eibert R; Egberts, Antoine C G; Gardarsdottir, Helga

    2016-10-01

    Treatment with antidepressants is often compromised by substantial nonadherence. To understand nonadherence, specific medication-related behaviors and beliefs have been studied, but less is known about broader and temporally stable personality "traits." Furthermore, adherence has often been assessed by a single method. Hence, we investigated associations between the Big Five personality traits and adherence assessed by self-report, electronic drug use monitoring, and dispensing data. Using the Big Five Inventory, we assessed the personality traits "openness," "conscientiousness," "extraversion," "agreeableness," and "neuroticism" of patients treated with antidepressants who were invited through community pharmacies. Self-reported adherence was assessed with the Medication Adherence Rating Scale (score >24), electronic monitoring with medication event monitoring system (MEMS) devices (therapy days missed ≤ 10% and personality traits, the third and fourth quartiles of "conscientiousness" were associated with better self-reported adherence (odds ratio, 3.63; 95% confidence interval, 1.34-9.86 and odds ratio, 2.97; 95% confidence interval, 1.09-8.08; P ≤ 0.05). No relationships were found between personality traits and adherence assessed through electronic drug use monitoring or dispensing data. We therefore conclude that adherence to antidepressant therapy seems to be largely unrelated to personality traits.

  9. A Large Hadron Electron Collider at CERN: Report on the Physics and Design Concepts for Machine and Detector

    CERN Document Server

    Abelleira Fernandez, J.L.; Akay, A.N.; Aksakal, H.; Albacete, J.L.; Alekhin, S.; Allport, P.; Andreev, V.; Appleby, R.B.; Arikan, E.; Armesto, N.; Azuelos, G.; Bai, M.; Barber, D.; Bartels, J.; Behnke, O.; Behr, J.; Belyaev, A.S.; Ben-Zvi, I.; Bernard, N.; Bertolucci, S.; Bettoni, S.; Biswal, S.; Blumlein, J.; Bottcher, H.; Bogacz, A.; Bracco, C.; Brandt, G.; Braun, H.; Brodsky, S.; Buning, O.; Bulyak, E.; Buniatyan, A.; Burkhardt, H.; Cakir, I.T.; Cakir, O.; Calaga, R.; Cetinkaya, V.; Ciapala, E.; Ciftci, R.; Ciftci, A.K.; Cole, B.A.; Collins, J.C.; Dadoun, O.; Dainton, J.; De Roeck, A.; d'Enterria, D.; Dudarev, A.; Eide, A.; Enberg, R.; Eroglu, E.; Eskola, K.J.; Favart, L.; Fitterer, M.; Forte, S.; Gaddi, A.; Gambino, P.; Garcia Morales, H.; Gehrmann, T.; Gladkikh, P.; Glasman, C.; Godbole, R.; Goddard, B.; Greenshaw, T.; Guffanti, A.; Guzey, V.; Gwenlan, C.; Han, T.; Hao, Y.; Haug, F.; Herr, W.; Herve, A.; Holzer, B.J.; Ishitsuka, M.; Jacquet, M.; Jeanneret, B.; Jimenez, J.M.; Jowett, J.M.; Jung, H.; Karadeniz, H.; Kayran, D.; Kilic, A.; Kimura, K.; Klein, M.; Klein, U.; Kluge, T.; Kocak, F.; Korostelev, M.; Kosmicki, A.; Kostka, P.; Kowalski, H.; Kramer, G.; Kuchler, D.; Kuze, M.; Lappi, T.; Laycock, P.; Levichev, E.; Levonian, S.; Litvinenko, V.N.; Lombardi, A.; Maeda, J.; Marquet, C.; Mellado, B.; Mess, K.H.; Milanese, A.; Moch, S.; Morozov, I.I.; Muttoni, Y.; Myers, S.; Nandi, S.; Nergiz, Z.; Newman, P.R.; Omori, T.; Osborne, J.; Paoloni, E.; Papaphilippou, Y.; Pascaud, C.; Paukkunen, H.; Perez, E.; Pieloni, T.; Pilicer, E.; Pire, B.; Placakyte, R.; Polini, A.; Ptitsyn, V.; Pupkov, Y.; Radescu, V.; Raychaudhuri, S.; Rinol, L.; Rohini, R.; Rojo, J.; Russenschuck, S.; Sahin, M.; Salgado, C.A.; Sampei, K.; Sassot, R.; Sauvan, E.; Schneekloth, U.; Schorner-Sadenius, T.; Schulte, D.; Senol, A.; Seryi, A.; Sievers, P.; Skrinsky, A.N.; Smith, W.; Spiesberger, H.; Stasto, A.M.; Strikman, M.; Sullivan, M.; Sultansoy, S.; Sun, Y.P.; Surrow, B.; Szymanowski, L.; Taels, P.; Tapan, I.; Tasci, T.; Tassi, E.; Ten Kate, H.; Terron, J.; Thiesen, H.; Thompson, L.; Tokushuku, K.; Tomas Garcia, R.; Tommasini, D.; Trbojevic, D.; Tsoupas, N.; Tuckmantel, J.; Turkoz, S.; Trinh, T.N.; Tywoniuk, K.; Unel, G.; Urakawa, J.; VanMechelen, P.; Variola, A.; Veness, R.; Vivoli, A.; Vobly, P.; Wagner, J.; Wallny, R.; Wallon, S.; Watt, G.; Weiss, C.; Wiedemann, U.A.; Wienands, U.; Willeke, F.; Xiao, B.W.; Yakimenko, V.; Zarnecki, A.F.; Zhang, Z.; Zimmermann, F.; Zlebcik, R.; Zomer, F.

    2012-01-01

    The physics programme and the design are described of a new collider for particle and nuclear physics, the Large Hadron Electron Collider (LHeC), in which a newly built electron beam of 60 GeV, up to possibly 140 GeV, energy collides with the intense hadron beams of the LHC. Compared to HERA, the kinematic range covered is extended by a factor of twenty in the negative four-momentum squared, $Q^2$, and in the inverse Bjorken $x$, while with the design luminosity of $10^{33}$ cm$^{-2}$s$^{-1}$ the LHeC is projected to exceed the integrated HERA luminosity by two orders of magnitude. The physics programme is devoted to an exploration of the energy frontier, complementing the LHC and its discovery potential for physics beyond the Standard Model with high precision deep inelastic scattering measurements. These are designed to investigate a variety of fundamental questions in strong and electroweak interactions. The physics programme also includes electron-deuteron and electron-ion scattering in a $(Q^2, 1/x)$ ran...

  10. Brief report: pulmonary auscultation in the operating room: a prospective randomized blinded trial comparing electronic and conventional stethoscopes.

    Science.gov (United States)

    Hoffmann, Clement; Falzone, Elisabeth; Verret, Catherine; Pasquier, Pierre; Leclerc, Thomas; Donat, Nicolas; Jost, Daniel; Mérat, Stephane; Maurice, Guillaume de Saint; Lenoir, Bernard; Auroy, Yves; Tourtier, Jean-Pierre

    2013-09-01

    We compared the subjective quality of pulmonary auscultation between 2 acoustic stethoscopes (Holtex Ideal® and Littmann Cardiology III®) and an electronic stethoscope (Littmann 3200®) in the operating room. A prospective double-blind randomized study with an evaluation during mechanical ventilation was performed in 100 patients. After each examination, the listeners using a numeric scale (0-10) rated the quality of auscultation. Auscultation quality was compared in patients among stethoscopes with a multilevel mixed-effects linear regression with random intercept (operator effect), adjusted on significant factors in univariate analysis. A significant difference was defined as P auscultation were performed. The quality of auscultation was rated 8.2 ± 1.6 for the electronic stethoscope, 7.4 ± 1.8 for the Littmann Cardiology III, and 4.6 ± 1.8 for the Holtex Ideal. Compared with Holtex Ideal, auscultation quality was significantly higher with other stethoscopes (P auscultation quality was significantly higher with Littmann 3200 electronic stethoscope (β = 0.9 [95% confidence interval, 0.5-1.3]). An electronic stethoscope can provide a better quality of pulmonary auscultation than acoustic stethoscopes in the operating room, yet with a magnitude of improvement marginally higher than that provided with a high performance acoustic stethoscope. Whether this can translate into a clinically relevant benefit requires further studies.

  11. Final Technical Report, Grant DE-FG02-91ER45443: Heavy fermions and other highly correlated electron systems

    International Nuclear Information System (INIS)

    Schlottmann, P.

    1998-01-01

    Properties of highly correlated electrons, such as heavy fermion compounds, metal-insulator transitions, one-dimensional conductors and systems of restricted dimensionality are studied theoretically. The main focus is on Kondo insulators and impurity bands due to Kondo holes, the low-temperature magnetoresistivity of heavy fermion alloys, the n-channel Kondo problem, mesoscopic systems and one-dimensional conductors

  12. Elevating Learner Achievement Using Formative Electronic Lab Assessments in the Engineering Laboratory: A Viable Alternative to Weekly Lab Reports

    Science.gov (United States)

    Chen, Baiyun; DeMara, Ronald F.; Salehi, Soheil; Hartshorne, Richard

    2018-01-01

    A laboratory pedagogy interweaving weekly student portfolios with onsite formative electronic laboratory assessments (ELAs) is developed and assessed within the laboratory component of a required core course of the electrical and computer engineering (ECE) undergraduate curriculum. The approach acts to promote student outcomes, and neutralize…

  13. Electronic states in tunneling semiconductor superlattices: Technical progress report for the period September 15, 1987-September 14, 1988

    International Nuclear Information System (INIS)

    Ulloa, S.E.

    1988-01-01

    This research project funded by DOE has concentrated in the systematic study of the effects of a gate voltage on the electronic structure of a tunneling superlattice system. The effects of strong magnetic fields and other various parameters on energy levels of tunneling superlattices have been investigated

  14. PHENIX reports. Final report

    International Nuclear Information System (INIS)

    1998-01-01

    The various tasks outlined in the Statement of Work for the PHENIX Program have been accomplished. Reports were generated which cover the work done. This report is a compilation of the following reports: Progress Report for May 1998; Progress Report for April 1998; PHENIX FEA Mount/Electron Shield Structural Analysis report; Progress Report for February 1998; Progress Report for March 1998; and Progress Report for December 1997 and January 1998

  15. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran’s Electronic Health Record (EHR) System

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. Aim: to determine the minimum data set of echocardiography reporting system to exchange with Iran’s electronic health record (EHR) system. Methods: First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients’ records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. Results: The highest degree of consensus was found for the following MDSs: patient’s name and family name (5), accepting doctor’s name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. Conclusions: To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran’s electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider. PMID:27147803

  16. Designing and evaluating an electronic patient falls reporting system: perspectives for the implementation of health information technology in long-term residential care facilities.

    Science.gov (United States)

    Mei, Yi You; Marquard, Jenna; Jacelon, Cynthia; DeFeo, Audrey L

    2013-11-01

    Patient falls are the leading cause of unintentional injury and death among older adults. In 2000, falls resulted in over 10,300 elderly deaths, costing the United States approximately $179 million in incidence and medical costs. Furthermore, non-fatal injuries caused by falls cost the United States $19 billion annually. Health information technology (IT) applications, specifically electronic falls reporting systems, can aid quality improvement efforts to prevent patient falls. Yet, long-term residential care facilities (LTRCFs) often do not have the financial resources to implement health IT, and workers in these settings are often not ready to adopt such systems. Additionally, most health IT evaluations are conducted in large acute-care settings, so LTRCF administrators currently lack evidence to support the value of health IT. In this paper, we detail the development of a novel, easy-to-use system to facilitate electronic patient falls reporting within a LTRCF using off-the-shelf technology that can be inexpensively implemented in a wide variety of settings. We report the results of four complimentary system evaluation measures that take into consideration varied organizational stakeholders' perspectives: (1) System-level benefits and costs, (2) system usability, via scenario-based use cases, (3) a holistic assessment of users' physical, cognitive, and marcoergonomic (work system) challenges in using the system, and (4) user technology acceptance. We report the viability of collecting and analyzing data specific to each evaluation measure and detail the relative merits of each measure in judging whether the system is acceptable to each stakeholder. The electronic falls reporting system was successfully implemented, with 100% reporting at 3-months post-implementation. The system-level benefits and costs approach showed that the electronic system required no initial investment costs aside from personnel costs and significant benefits accrued from user time savings

  17. Interaction of slow electrons with high-pressure gases (Quasi-liquids). Synthesis of our knowledge on slow electron-molecule interactions. Progress report for year ending June 15, 1984

    International Nuclear Information System (INIS)

    McCorkle, D.L.; Christophorou, L.G.

    1984-01-01

    A crucial step in efforts to develop not only a coherent picture of radiation interaction with matter, but also to understand radiation effects and mechanisms, as well as the effects of chemical pollutants and toxic compounds, is to relate the often abundant knowledge on isolated molecules (low pressure gases) to that on liquids or solids. To understand the roles of the physical and chemical properties of molecules in biological reactions, the way these isolated-molecule properties change as molecules are embedded in gradually thicker and thicker (denser and denser) gaseous and, finally, liquid environments must be known. The work reported here, carried out both at the Physics Department of the University of Tennessee and at the Oak Ridge National Laboratory addresses itself to this question. At both places, high pressure (40 to approx. 8000 kPa) electron swarm experiments are currently in operation yielding the first information as to the effects of the density and nature of the environment on fundamental electron-molecule interaction processes at densities intermediate to those corresponding to low pressure gases and liquids, and the gradual transition from isolated molecule to condensed phase behavior. Basic physical data on the electronic states of atmospheric halocarbons in general, and of polycyclic aromatic hydrocarbons in particular were also studied. Such data are of special significance because of the occurrence of these molecules in the atmosphere, and are presently lacking

  18. Electron Beam Generation in Tevatron Electron Lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  19. Electron beam generation in Tevatron electron lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  20. A quantitative and qualitative evaluation of reports of clinical trials published in six Brazilian dental journals indexed in the Scientific Electronic Library Online (SciELO

    Directory of Open Access Journals (Sweden)

    Raphael Freitas de Souza

    2010-04-01

    Full Text Available INTRODUCTION: Open access publishing is becoming increasingly popular within the biomedical sciences. SciELO, the Scientific Electronic Library Online, is a digital library covering a selected collection of Brazilian scientific journals many of which provide open access to full-text articles.This library includes a number of dental journals some of which may include reports of clinical trials in English, Portuguese and/or Spanish. Thus, SciELO could play an important role as a source of evidence for dental healthcare interventions especially if it yields a sizeable number of high quality reports. OBJECTIVE: The aim of this study was to identify reports of clinical trials by handsearching of dental journals that are accessible through SciELO, and to assess the overall quality of these reports. MATERIAL AND METHODS: Electronic versions of six Brazilian dental Journals indexed in SciELO were handsearched at www.scielo.br in September 2008. Reports of clinical trials were identified and classified as controlled clinical trials (CCTs - prospective, experimental studies comparing 2 or more healthcare interventions in human beings or randomized controlled trials (RCTs - a random allocation method is clearly reported, according to Cochrane eligibility criteria. CRITERIA TO ASSESS METHODOLOGICAL QUALITY INCLUDED: method of randomization, concealment of treatment allocation, blinded outcome assessment, handling of withdrawals and losses and whether an intention-to-treat analysis had been carried out. RESULTS: The search retrieved 33 CCTs and 43 RCTs. A majority of the reports provided no description of either the method of randomization (75.3% or concealment of the allocation sequence (84.2%. Participants and outcome assessors were reported as blinded in only 31.2% of the reports. Withdrawals and losses were only clearly described in 6.5% of the reports and none mentioned an intention-to-treat analysis or any similar procedure. CONCLUSIONS: The results of

  1. A quantitative and qualitative evaluation of reports of clinical trials published in six Brazilian dental journals indexed in the Scientific Electronic Library Online (SciELO).

    Science.gov (United States)

    de Souza, Raphael Freitas; Chaves, Carolina de Andrade Lima; Nasser, Mona; Fedorowicz, Zbys

    2010-01-01

    Open access publishing is becoming increasingly popular within the biomedical sciences. SciELO, the Scientific Electronic Library Online, is a digital library covering a selected collection of Brazilian scientific journals many of which provide open access to full-text articles.This library includes a number of dental journals some of which may include reports of clinical trials in English, Portuguese and/or Spanish. Thus, SciELO could play an important role as a source of evidence for dental healthcare interventions especially if it yields a sizeable number of high quality reports. The aim of this study was to identify reports of clinical trials by handsearching of dental journals that are accessible through SciELO, and to assess the overall quality of these reports. Electronic versions of six Brazilian dental Journals indexed in SciELO were handsearched at www.scielo.br in September 2008. Reports of clinical trials were identified and classified as controlled clinical trials (CCTs - prospective, experimental studies comparing 2 or more healthcare interventions in human beings) or randomized controlled trials (RCTs - a random allocation method is clearly reported), according to Cochrane eligibility criteria. CRITERIA TO ASSESS METHODOLOGICAL QUALITY INCLUDED: method of randomization, concealment of treatment allocation, blinded outcome assessment, handling of withdrawals and losses and whether an intention-to-treat analysis had been carried out. The search retrieved 33 CCTs and 43 RCTs. A majority of the reports provided no description of either the method of randomization (75.3%) or concealment of the allocation sequence (84.2%). Participants and outcome assessors were reported as blinded in only 31.2% of the reports. Withdrawals and losses were only clearly described in 6.5% of the reports and none mentioned an intention-to-treat analysis or any similar procedure. The results of this study indicate that a substantial number of reports of trials and systematic

  2. Single-electron charging effects

    International Nuclear Information System (INIS)

    Ruggiero, S.T.

    1991-01-01

    The status of our project on single-electron tunneling is, again, excellent. As outlined in our original proposal, a key goal in the development of this project was the demonstration and exploration of the microwave properties of single-electron system. As discussed in this paper such work has to data been carried out. Also as discussed in our previous progress report, the next step in the experimental evolution of the project will be to use lithographically-defined small dots as capacitors as outlined in our proposal. At this point we have made such microdotsdots as will be discussed. We have also continued our work with metal droplets to form single-electron tunnel systems

  3. Tracking of boron-labelled monoclonal antibodies by energy loss spectroscopy in the electron microscope: a preliminary report

    International Nuclear Information System (INIS)

    Moore, D.E.; Dawes, A.L.; Chandler, A.K.; Bradstock, K.F.

    1990-01-01

    A technique is being developed, based on electron energy loss spectroscopy in the transmission electron microscope, whereby the binding of monoclonal antibodies to their specific receptors and any subsequent movement or endocytosis can be studied in cell culture. The method requires that antibodies be labelled with a low atomic number element, such as boron. Two procedures have been established enabling up to 1200 boron atoms to be attached per antibody molecule without affecting the immunoreactivity. In the first method, dodecaborane cages are attached to polyornithine bridging molecules which in turn are covalently bound to the antibody using a photosensitive reagent. The second technique makes use of the extremely high biotin-avidin affinity by attaching biotin to the antibody and dodecaborane cages to avidin before mixing the two components. 13 refs., 2 figs

  4. Final Technical Report [Scalable methods for electronic excitations and optical responses of nanostructures: mathematics to algorithms to observables

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Yousef

    2014-03-19

    The master project under which this work is funded had as its main objective to develop computational methods for modeling electronic excited-state and optical properties of various nanostructures. The specific goals of the computer science group were primarily to develop effective numerical algorithms in Density Functional Theory (DFT) and Time Dependent Density Functional Theory (TDDFT). There were essentially four distinct stated objectives. The first objective was to study and develop effective numerical algorithms for solving large eigenvalue problems such as those that arise in Density Functional Theory (DFT) methods. The second objective was to explore so-called linear scaling methods or Methods that avoid diagonalization. The third was to develop effective approaches for Time-Dependent DFT (TDDFT). Our fourth and final objective was to examine effective solution strategies for other problems in electronic excitations, such as the GW/Bethe-Salpeter method, and quantum transport problems.

  5. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, John P., E-mail: john.gibbons@marybird.com [Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana 70809 (United States); Antolak, John A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Followill, David S. [Department of Radiation Physics, UT M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania 15232 (United States); Klein, Eric E. [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Lam, Kwok L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Palta, Jatinder R. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Roback, Donald M. [Department of Radiation Oncology, Cancer Centers of North Carolina, Raleigh, North Carolina 27607 (United States); Reid, Mark [Department of Medical Physics, Fletcher-Allen Health Care, Burlington, Vermont 05401 (United States); Khan, Faiz M. [Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-03-15

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  6. A method for finding D-region electron density distributions from lf broadband pulse measurements. Telecommunications research and engineering report

    International Nuclear Information System (INIS)

    Wieder, B.; Espeland, R.H.

    1972-11-01

    A Loran-C transmitter is used as the signal source for the experiment. In the experiment, both the normal and abnormal components of the pulses reflected from the ionosphere are measured, and the reflection coeffeicients are determined as a function of frequency through Fourier analysis of both the groundwave and the skywave signals. The resultant data are then compared with reflection coefficients calculated from a series of test D-region electron density profiles

  7. Intraoperative radiation therapy using mobile electron linear accelerators: Report of AAPM Radiation Therapy Committee Task Group No. 72

    International Nuclear Information System (INIS)

    Sam Beddar, A.; Biggs, Peter J.; Chang Sha; Ezzell, Gary A.; Faddegon, Bruce A.; Hensley, Frank W.; Mills, Michael D.

    2006-01-01

    Intraoperative radiation therapy (IORT) has been customarily performed either in a shielded operating suite located in the operating room (OR) or in a shielded treatment room located within the Department of Radiation Oncology. In both cases, this cancer treatment modality uses stationary linear accelerators. With the development of new technology, mobile linear accelerators have recently become available for IORT. Mobility offers flexibility in treatment location and is leading to a renewed interest in IORT. These mobile accelerator units, which can be transported any day of use to almost any location within a hospital setting, are assembled in a nondedicated environment and used to deliver IORT. Numerous aspects of the design of these new units differ from that of conventional linear accelerators. The scope of this Task Group (TG-72) will focus on items that particularly apply to mobile IORT electron systems. More specifically, the charges to this Task Group are to (i) identify the key differences between stationary and mobile electron linear accelerators used for IORT (ii) describe and recommend the implementation of an IORT program within the OR environment, (iii) present and discuss radiation protection issues and consequences of working within a nondedicated radiotherapy environment, (iv) describe and recommend the acceptance and machine commissioning of items that are specific to mobile electron linear accelerators, and (v) design and recommend an efficient quality assurance program for mobile systems

  8. FINAL REPORT: Scalable Methods for Electronic Excitations and Optical Responses of Nanostructures: Mathematics to Algorithms to Observables

    Energy Technology Data Exchange (ETDEWEB)

    Chelikowsky, James R. [Univ. of Texas, Austin, TX (United States)

    2013-04-01

    Work in nanoscience has increased substantially in recent years owing to its potential technological applications and to fundamental scientific interest. A driving force for this activity is to capitalize on new phenomena that occurs at the nanoscale. For example, the physical confinement of electronic states, i.e., quantum confinement, can dramatically alter the electronic and optical properties of matter. A prime example of this occurs for the optical properties of nanoscale crystals such as those composed of elemental silicon. Silicon in the bulk state is optically inactive due to the small size of the optical gap, which can only be accessed by indirect transitions. However, at the nanoscale, this material becomes optically active. The size of the optical gap is increased by confinement and the conservation of crystal momentum ceases to hold, resulting in the viability of indirect transitions. Our work associated with this grant has focused on developing new scalable algorithms for describing the electronic and optical properties of matter at the nanoscale such as nano structures of silicon and related semiconductor properties.

  9. Radiation damage measurements on nonmetals made during irradiation with 1 to 3 MeV electrons. Final Report

    International Nuclear Information System (INIS)

    Levy, P.W.

    1982-01-01

    To investigate the fundamental processes producing radiation damage in nonmetals a unique facility has been developed for making optical absorption, luminescence and other measurements during irradiation with 1 to 3 MeV electrons. Measurements are made with a 13 meter long double beam spectrometer arranged so that all sensitive components, e.g., phototubes, are outside of the irradiation chamber. A computer provdies automatic control and data recording. A 256 point absorption and a 256 point luminescence spectra are recorded as often as every 40 seconds in either the 200-400 or 400-800 mm wavelength range. Samples are irradiated, at temperatures between 20 and 900 C, in an electronically controlled chamber containing He exchange gas and equipped with thin Havar windows to transmit the electron beam and high purity fused silica windows for the spectrophotometer beams. Radiation induced luminescence and absorption in the chamber windows, etc. is eliminated by the double beam spectrophotometer. Studies made with this equipment demonstrate clearly that many of the processes occurring during damage formation are transient

  10. Control of spiking in partial penetration of electron beam welds. Final report, 1 October 1969--1 October 1976

    International Nuclear Information System (INIS)

    1976-01-01

    An investigation of the penetration mechanism of high energy density electron beams and an evaluation of electron beam deflection as a method of penetration control are presented. A discussion of electron beam mechanics including several penetration theories is presented in the introduction and background. Slur radiographs made using a pinhole x-ray camera are evaluated to determine velocity and acceleration of the point of beam impingement. Methods of cavity closure are discussed with possible causes of surface sealing of the beam cavity. A method of penetration, after the cavity has closed, based on the curves relating velocity and acceleration to penetration distance is considered. An estimate of cavity pressure is made from the maximum acceleration of the beam-metal interface. A system using an x-ray detector coupled with a beam deflecting device is detailed and evaluated. As this is the first attempt at penetration control by beam deflection the investigation seeks only to determine the feasibility of the idea without attempting a thorough analysis of range of abilities or quality of welds made by such devices. Based on several specimens which are presented beam deflection appears capable of controlling penetration depth. It is hoped that the ideas presented here will inspire future research along these lines

  11. EDITORIAL: Synaptic electronics Synaptic electronics

    Science.gov (United States)

    Demming, Anna; Gimzewski, James K.; Vuillaume, Dominique

    2013-09-01

    Conventional computers excel in logic and accurate scientific calculations but make hard work of open ended problems that human brains handle easily. Even von Neumann—the mathematician and polymath who first developed the programming architecture that forms the basis of today's computers—was already looking to the brain for future developments before his death in 1957 [1]. Neuromorphic computing uses approaches that better mimic the working of the human brain. Recent developments in nanotechnology are now providing structures with very accommodating properties for neuromorphic approaches. This special issue, with guest editors James K Gimzewski and Dominique Vuillaume, is devoted to research at the serendipitous interface between the two disciplines. 'Synaptic electronics', looks at artificial devices with connections that demonstrate behaviour similar to synapses in the nervous system allowing a new and more powerful approach to computing. Synapses and connecting neurons respond differently to incident signals depending on the history of signals previously experienced, ultimately leading to short term and long term memory behaviour. The basic characteristics of a synapse can be replicated with around ten simple transistors. However with the human brain having around 1011 neurons and 1015 synapses, artificial neurons and synapses from basic transistors are unlikely to accommodate the scalability required. The discovery of nanoscale elements that function as 'memristors' has provided a key tool for the implementation of synaptic connections [2]. Leon Chua first developed the concept of the 'The memristor—the missing circuit element' in 1971 [3]. In this special issue he presents a tutorial describing how memristor research has fed into our understanding of synaptic behaviour and how they can be applied in information processing [4]. He also describes, 'The new principle of local activity, which uncovers a minuscule life-enabling "Goldilocks zone", dubbed the

  12. Electron beam generation form a superemissive cathode

    International Nuclear Information System (INIS)

    Hsu, T.-Y.; Liou, R.-L.; Kirkman-Amemiya, G.; Gundersen, M.A.

    1991-01-01

    An experimental study of electron beams produced by a superemissive cathode in the Back-Lighted Thyratron (BLT) and the pseudospark is presented. This work is motivated by experiments demonstrating very high current densities (≥10 kA/cm 2 over an area of 1 cm 2 ) from the pseudospark and BLT cathode. This high-density current is produced by field-enhanced thermionic emission from the ion beam-heated surface of a molybdenum cathode. This work reports the use of this cathode as a beam source, and is to be distinguished from previous work reporting hollow cathode-produced electron beams. An electron beam of more than 260 A Peak current has been produced with 15 kV applied voltage. An efficiency of ∼10% is estimated. These experimental results encourage further investigation of the super-emissive cathode as an intense electron beam source for applications including accelerator technology

  13. Nuclear scattering studies by the scattering of medium-energy electrons. Progress report, January 1, 1977--October 31, 1977

    International Nuclear Information System (INIS)

    Peterson, G.A.

    1977-10-01

    Tune-up experiments were carried out at the Bates Linear Accelerator of Middleton, Massachusetts, on the 180 0 electron scattering apparatus designed and constructed by the University of Massachusetts under contract E(11-1)-2545. This apparatus serves as adjunct equipment to the Bates dispersion-matching spectrometer. Form factors were measured for the low-lying states of 27 Al over the momentum transfer range from 0.7 to 2.6 fm -1 . A paper was published in the Physical Review on low-momentum transfer elastic electron scattering from 3 He. The 3 He rms radius was determined to be 1.89 +- 0.05 fm from measurements made at the National Bureau of Standards over the momentum transfer range-squared between 0.032 and 0.34 fm -2 . A Physical Review paper was published in November, 1977, on the results of elastic electron scattering from 25 Mg over the momentum transfer range from 0.19 to 2.56 fm -1 at both forward and backward angles. Values of all of the ground-state multipole moments of both Coulomb and magnetic character were obtained. A paper was submitted for publication on the electroexcitation of giant dipole and quadrupole resonances in 20 Ne. Electric dipole and quadrupole strength was found throughout the region from 12.5 through 25 MeV. About 65% and 100% of the energy-weighted dipole and quadrupole sum rules, respectively, were exhausted. A preliminary run was made on 42 Ca and 44 Ca at the National Bureau of Standards for an incident electron energy of 54.3 MeV and a 145 0 scattering angle in an attempt to observe f/sub 7 / 2 / to f/sub 5 / 2 / magnetic dipole transitions. A paper was composed on the 160 0 inelastic scattering of electrons from 58 Ni at momentum transfers near 2 fm -1 . Strong M8 transitions were observed which are characterized by predominantly one particle--one hole excitations characterized by the configuration

  14. Cerebral Metastasis from a Previously Undiagnosed Appendiceal Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Antonio Biroli

    2012-01-01

    Full Text Available Brain metastases arise in 10%–40% of all cancer patients. Up to one third of the patients do not have previous cancer history. We report a case of a 67-years-old male patient who presented with confusion, tremor, and apraxia. A brain MRI revealed an isolated right temporal lobe lesion. A thorax-abdomen-pelvis CT scan showed no primary lesion. The patient underwent a craniotomy with gross-total resection. Histopathology revealed an intestinal-type adenocarcinoma. A colonoscopy found no primary lesion, but a PET-CT scan showed elevated FDG uptake in the appendiceal nodule. A right hemicolectomy was performed, and the specimen showed a moderately differentiated mucinous appendiceal adenocarcinoma. Whole brain radiotherapy was administrated. A subsequent thorax-abdomen CT scan revealed multiple lung and hepatic metastasis. Seven months later, the patient died of disease progression. In cases of undiagnosed primary lesions, patients present in better general condition, but overall survival does not change. Eventual identification of the primary tumor does not affect survival. PET/CT might be a helpful tool in detecting lesions of the appendiceal region. To the best of our knowledge, such a case was never reported in the literature, and an appendiceal malignancy should be suspected in patients with brain metastasis from an undiagnosed primary tumor.

  15. Gastrointestinal tolerability with ibandronate after previous weekly bisphosphonate treatment.

    Science.gov (United States)

    Derman, Richard; Kohles, Joseph D; Babbitt, Ann

    2009-01-01

    Data from two open-label trials (PRIOR and CURRENT) of women with postmenopausal osteoporosis or osteopenia were evaluated to assess whether monthly oral and quarterly intravenous (IV) ibandronate dosing improved self-reported gastrointestinal (GI) tolerability for patients who had previously experienced GI irritation with bisphosphonate (BP) use. In PRIOR, women who had discontinued daily or weekly BP treatment due to GI intolerance received monthly oral or quarterly IV ibandronate for 12 months. The CURRENT subanalysis included women receiving weekly BP treatment who switched to monthly oral ibandronate for six months. GI symptom severity and frequency were assessed using the Osteoporosis Patient Satisfaction Questionnaire. In PRIOR, mean GI tolerability scores increased significantly at month 1 from screening for both treatment groups (oral: 79.3 versus 54.1; IV: 84.4 versus 51.0; p 90% at Month 10). In the CURRENT subanalysis >60% of patients reported improvements in heartburn or acid reflux and >70% indicated improvement in other stomach upset at month 6. Postmenopausal women with GI irritability with daily or weekly BPs experienced improvement in symptoms with extended dosing monthly or quarterly ibandronate compared with baseline.

  16. 75 FR 34260 - Federal Acquisition Regulation; FAR Case 2005-040, Electronic Subcontracting Reporting System (eSRS)

    Science.gov (United States)

    2010-06-16

    ... plan. Failure to submit or late submission of reports shall be a breach of contract and will be...)(2) of FAR clause 52.219-9 already addresses the breach of contract issue when the contractor or... Form 294 - Subcontract Report for Individual Contracts and Standard Form 295 - Summary Subcontract...

  17. Electronics Research Laboratory, Plasma Theory and Simulation Group annual progress report, January 1, 1989--December 31, 1989

    International Nuclear Information System (INIS)

    Birdsall, C.K.

    1989-01-01

    This is a brief progress report, covering our research in general plasma theory and simulation, plasma-wall physics theory and simulation, and code development. Reports written in this period are included with this mailing. A publications list plus abstracts for two major meetings are included

  18. Electronic symptom reporting between patient and provider for improved health care service quality: a systematic review of randomized controlled trials. part 1: state of the art.

    Science.gov (United States)

    Johansen, Monika Alise; Henriksen, Eva; Horsch, Alexander; Schuster, Tibor; Berntsen, Gro K Rosvold

    2012-10-03

    Over the last two decades, the number of studies on electronic symptom reporting has increased greatly. However, the field is very heterogeneous: the choices of patient groups, health service innovations, and research targets seem to involve a broad range of foci. To move the field forward, it is necessary to build on work that has been done and direct further research to the areas holding most promise. Therefore, we conducted a comprehensive review of randomized controlled trials (RCTs) focusing on electronic communication between patient and provider to improve health care service quality, presented in two parts. Part 2 investigates the methodological quality and effects of the RCTs, and demonstrates some promising benefits of electronic symptom reporting. To give a comprehensive overview of the most mature part of this emerging field regarding (1) patient groups, (2) health service innovations, and (3) research targets relevant to electronic symptom reporting. We searched Medline, EMBASE, PsycINFO, Cochrane Central Register of Controlled Trials, and IEEE Xplore for original studies presented in English-language articles published from 1990 to November 2011. Inclusion criteria were RCTs of interventions where patients or parents reported health information electronically to the health care system for health care purposes and were given feedback. Of 642 records identified, we included 32 articles representing 29 studies. The included articles were published from 2002, with 24 published during the last 5 years. The following five patient groups were represented: respiratory and lung diseases (12 studies), cancer (6), psychiatry (6), cardiovascular (3), and diabetes (1). In addition to these, 1 study had a mix of three groups. All included studies, except 1, focused on long-term conditions. We identified four categories of health service innovations: consultation support (7 studies), monitoring with clinician support (12), self-management with clinician support (9

  19. Gastrointestinal tolerability with ibandronate after previous weekly bisphosphonate treatment

    Directory of Open Access Journals (Sweden)

    Richard Derman

    2009-09-01

    Full Text Available Richard Derman1, Joseph D Kohles2, Ann Babbitt31Department of Obstetrics and Gynecology, Christiana Hospital, Newark, DE, USA; 2Roche, Nutley, NJ, USA; 3Greater Portland Bone and Joint Specialists, Portland, ME, USAAbstract: Data from two open-label trials (PRIOR and CURRENT of women with postmenopausal osteoporosis or osteopenia were evaluated to assess whether monthly oral and quarterly intravenous (IV ibandronate dosing improved self-reported gastrointestinal (GI tolerability for patients who had previously experienced GI irritation with bisphosphonate (BP use. In PRIOR, women who had discontinued daily or weekly BP treatment due to GI intolerance received monthly oral or quarterly IV ibandronate for 12 months. The CURRENT subanalysis included women receiving weekly BP treatment who switched to monthly oral ibandronate for six months. GI symptom severity and frequency were assessed using the Osteoporosis Patient Satisfaction Questionnaire™. In PRIOR, mean GI tolerability scores increased significantly at month 1 from screening for both treatment groups (oral: 79.3 versus 54.1; IV: 84.4 versus 51.0; p < 0.001 for both. Most patients reported improvement in GI symptom severity and frequency from baseline at all post-screening assessments (>90% at Month 10. In the CURRENT subanalysis >60% of patients reported improvements in heartburn or acid reflux and >70% indicated improvement in other stomach upset at month 6. Postmenopausal women with GI irritability with daily or weekly BPs experienced improvement in symptoms with extended dosing monthly or quarterly ibandronate compared with baseline.Keywords: ibandronate, osteoporosis, bisphosphonate, gastrointestinal

  20. Spin electronics

    CERN Document Server

    Buhrman, Robert; Daughton, James; Molnár, Stephan; Roukes, Michael

    2004-01-01

    This report is a comparative review of spin electronics ("spintronics") research and development activities in the United States, Japan, and Western Europe conducted by a panel of leading U.S. experts in the field. It covers materials, fabrication and characterization of magnetic nanostructures, magnetism and spin control in magnetic nanostructures, magneto-optical properties of semiconductors, and magnetoelectronics and devices. The panel's conclusions are based on a literature review and a series of site visits to leading spin electronics research centers in Japan and Western Europe. The panel found that Japan is clearly the world leader in new material synthesis and characterization; it is also a leader in magneto-optical properties of semiconductor devices. Europe is strong in theory pertaining to spin electronics, including injection device structures such as tunneling devices, and band structure predictions of materials properties, and in development of magnetic semiconductors and semiconductor heterost...