WorldWideScience

Sample records for previous measurements evaluations

  1. Evaluation of protection measurements for rural environments

    International Nuclear Information System (INIS)

    Silva, Diogo N.G.; Silva, Fernanda L.; Conti, Luiz F.; Wasserman, Maria Angelica V.; Rochedo, Elaine R.R.

    2011-01-01

    Among the planning activities of actuation in nuclear/radiological emergences, it is included the efficiency evaluation of protection and remediation measurements. From the development of a data base on such measurements for the agricultural areas, the program SIEM was used for effectuation the simulations involving the 137 Cs, 131 I and 90 Sr radionuclides, in scenery previously established for simulation those areas of a 50 km surrounding the Admiral Alvaro Alberto nuclear power plant. The obtained results indicate that the scenery is determinant of efficiency measurements involving various specific factors of each place, such as: agricultural and cattle breeding products, consumption habits of population and the grade of subsistence by the diet items, making not practical the elaboration of predefined generic sceneries. The great dependence on seasoning related to the moment of accident makes inadequate any previous evaluation what soever for evaluation of efficiency of protection and remediation measurements. Therefore, previous decisions are not recommended about the relevance of protection measurements for rural areas. Two classification criteria were defined: (i) the efficiency in reduction the doses in the firs year; and, (i i) efficiency in reduction the dose at long term

  2. A website evaluation model by integration of previous evaluation models using a quantitative approach

    Directory of Open Access Journals (Sweden)

    Ali Moeini

    2015-01-01

    Full Text Available Regarding the ecommerce growth, websites play an essential role in business success. Therefore, many authors have offered website evaluation models since 1995. Although, the multiplicity and diversity of evaluation models make it difficult to integrate them into a single comprehensive model. In this paper a quantitative method has been used to integrate previous models into a comprehensive model that is compatible with them. In this approach the researcher judgment has no role in integration of models and the new model takes its validity from 93 previous models and systematic quantitative approach.

  3. Combining complexity measures of EEG data: multiplying measures reveal previously hidden information.

    Science.gov (United States)

    Burns, Thomas; Rajan, Ramesh

    2015-01-01

    Many studies have noted significant differences among human electroencephalograph (EEG) results when participants or patients are exposed to different stimuli, undertaking different tasks, or being affected by conditions such as epilepsy or Alzheimer's disease. Such studies often use only one or two measures of complexity and do not regularly justify their choice of measure beyond the fact that it has been used in previous studies. If more measures were added to such studies, however, more complete information might be found about these reported differences. Such information might be useful in confirming the existence or extent of such differences, or in understanding their physiological bases. In this study we analysed publically-available EEG data using a range of complexity measures to determine how well the measures correlated with one another. The complexity measures did not all significantly correlate, suggesting that different measures were measuring unique features of the EEG signals and thus revealing information which other measures were unable to detect. Therefore, the results from this analysis suggests that combinations of complexity measures reveal unique information which is in addition to the information captured by other measures of complexity in EEG data. For this reason, researchers using individual complexity measures for EEG data should consider using combinations of measures to more completely account for any differences they observe and to ensure the robustness of any relationships identified.

  4. Measurement evaluation

    CERN Document Server

    Boros, A

    1990-01-01

    The information obtained about a measured object is called ``crude'' measurement information and must be related to the conditions under which the measurement took place. Using ``crude'' measurement information as a starting point, evaluation produces physically correctly interpreted data with their estimated (or corrected) error. Although a number of works deal with the evaluation of measurements, they either appeared a long time ago or serve essentially different aims. This book gives a comprehensive and current overview on the basic principles, aids, devices, and methods in the eval

  5. Accuracy evaluation of pendulum gravity measurements of Robert von Sterneck

    Directory of Open Access Journals (Sweden)

    Alena Pešková

    2015-06-01

    Full Text Available The accuracy of first pendulum gravity measurements in the Czech territory was determined using both original surveying notebooks of Robert Daublebsky von Sterneck and modern technologies. Since more accurate methods are used for gravity measurements nowadays, our work is mostly important from the historical point of view. In previous  works, the accuracy of Sterneck’s gravity measurements was determined using only a small dataset. Here we process all Sterneck’s measurements from the Czech territory (a dataset ten times larger than in the previous works, and we complexly assess the accuracy of these measurements. Locations of the measurements were found with the help of original notebooks. Gravity in the site was interpolated using actual gravity models. Finally, the accuracy of Sterneck’s measurements was evaluated as the difference between the measured and interpolated gravity.

  6. Evaluation of protection measurements for rural environments; Avaliacao de medidas de protecao para ambientes rurais

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Diogo N.G.; Silva, Fernanda L.; Conti, Luiz F., E-mail: dneves@ird.gov.b, E-mail: lfcconti@ird.gov.b, E-mail: fleite@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica V., E-mail: maria.wasserman@pq.cnpq.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rochedo, Elaine R.R., E-mail: erochedo@cnen.gov.b [Comissao Nacional de Energia Nuclear (CODIN/CNEN), Rio de Janeiro, RJ (Brazil). Coord. de Instalacoes Nucleares

    2011-10-26

    Among the planning activities of actuation in nuclear/radiological emergences, it is included the efficiency evaluation of protection and remediation measurements. From the development of a data base on such measurements for the agricultural areas, the program SIEM was used for effectuation the simulations involving the {sup 137}Cs, {sup 131}I and {sup 90}Sr radionuclides, in scenery previously established for simulation those areas of a 50 km surrounding the Admiral Alvaro Alberto nuclear power plant. The obtained results indicate that the scenery is determinant of efficiency measurements involving various specific factors of each place, such as: agricultural and cattle breeding products, consumption habits of population and the grade of subsistence by the diet items, making not practical the elaboration of predefined generic sceneries. The great dependence on seasoning related to the moment of accident makes inadequate any previous evaluation what soever for evaluation of efficiency of protection and remediation measurements. Therefore, previous decisions are not recommended about the relevance of protection measurements for rural areas. Two classification criteria were defined: (i) the efficiency in reduction the doses in the firs year; and, (i i) efficiency in reduction the dose at long term

  7. Scientific opinion on the evaluation of substances as acceptable previous cargoes for edible fats and oils

    NARCIS (Netherlands)

    Knutsen, Helle Katrine; Alexander, Jan; Barregård, Lars; Bignami, Margherita; Brüschweiler, Beat; Ceccatelli, Sandra; Cottrill, Bruce; Dinovi, Michael; Edler, Lutz; Hogstrand, Christer; Hoogenboom, L.A.P.; Nebbia, Carlo; Oswald, Isabelle; Petersen, Annette; Rose, Martin; Roudot, Alain-Claude; Schwerdtle, Tanja; Vollmer, Günter; Wallace, Heather; Grasl-Kraupp, Bettina; Grob, Konrad; Penninks, André; Binaglia, Marco; Roldán Torres, Ruth; Vleminckx, Christiane

    2017-01-01

    Shipping of edible fats and oils into Europe is permitted in bulk tanks, provided that the previous cargo is included in a positive list. The European Commission requested EFSA to evaluate the acceptability as previous cargoes for fats and oils the substances calcium lignosulphonate, methyl acetate,

  8. Measured and evaluated fast neutron cross sections of elemental nickel

    International Nuclear Information System (INIS)

    Guenther, P.; Smith, A.; Smith, D.; Whalen, J.; Howerton, R.

    1975-07-01

    Fast neutron total and scattering cross sections of elemental nickel are measured. Differential elastic scattering cross sections are determined from incident energies of 0.3 to 4.0 MeV. The cross sections for the inelastic neutron excitation of states at: 1.156 +- 0.015, 1.324 +- 0.015, 1.443 +- 0.015, 2.136 +- 0.013, 2.255 +- 0.030, 2.449 +- 0.030, 2.614 +- 0.020 and 2.791 +- 0.025 MeV are measured to incident neutron energies of 4.0 MeV. The total neutron cross sections are determined from 0.25 to 5.0 MeV. The experimental results are discussed in the context of optical and statistical models. It is shown that resonance width-fluctuation and correlation effects are significant. The present experimental and theoretical results, together with previously reported values, are used to construct a comprehensive evaluated elemental data file in the ENDF format. Some comparisons are made with previously reported evaluated files. In addition, some selected reactions which are widely used in dosimetry and other applications are presented as supplemental evaluated isotopic-data files. The numerical quantities are presented in tabular form. (3 tables, 29 figures)

  9. Measure Evaluation Dataverse

    Data.gov (United States)

    US Agency for International Development — The MEASURE Evaluation Dataverse is a collection of innovative evaluation data sets assembled in order to increase the evidence-base on program impact and evaluate...

  10. Scientific opinion on the evaluation of substances as acceptable previous cargoes for edible fats and oils

    DEFF Research Database (Denmark)

    Petersen, Annette

    Shipping of edible fats and oils into Europe is permitted in bulk tanks, provided that the previous cargo is included in a positive list. The European Commission requested EFSA to evaluate the acceptability as previous cargoes for fats and oils the substances calcium lignosulphonate, methyl acetate...... the criteria for acceptability as previous cargoes. Due to uncertainties, mainly with regard to the composition and toxicity of the low molecular mass fraction, and the fact that the toxicological database is limited to the 40–65 grade and does not cover all grades of calcium lignosulphonate shipped...... as previous cargoes, the EFSA Panel on Contaminants in the Food Chain (CONTAM Panel) concluded that calcium lignosulphonate does not meet the criteria for acceptability as a previous cargo. Only food-grade ammonium sulphate meets the criteria for acceptability as a previous cargo due to uncertainties about...

  11. Evaluation of accountability measurements

    International Nuclear Information System (INIS)

    Cacic, C.G.

    1988-01-01

    The New Brunswick Laboratory (NBL) is programmatically responsible to the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) for providing independent review and evaluation of accountability measurement technology in DOE nuclear facilities. This function is addressed in part through the NBL Safegaurds Measurement Evaluation (SME) Program. The SME Program utilizes both on-site review of measurement methods along with material-specific measurement evaluation studies to provide information concerning the adequacy of subject accountability measurements. This paper reviews SME Program activities for the 1986-87 time period, with emphasis on noted improvements in measurement capabilities. Continued evolution of the SME Program to respond to changing safeguards concerns is discussed

  12. Evaluation of protection measurements for urban environments

    International Nuclear Information System (INIS)

    Rochedo, Elaine R.R.; Wasserman, Maria Angelica V.

    2011-01-01

    Radioactive accidents has shown the necessity of a previous evaluation planning of exposure and directives for implementation of protection measurements. The description or measurements in the literature usually is associated to reduction of concentrations in the medium where they are applied. For verification the efficiency in dose reduction, it is necessary to proceed simulations. Through the development of data base on protection measurements, it was established basic sceneries, typically tropical as far the building type is concerned and the construction material. The program SIEM was used for simulation of contamination with 137 Cs. The results indicates that generic solutions persuade not to and the decision make processes should be effectuated according to the real conditions of contamination and the use of affected area. For affected areas, two classification criteria were defined: (1) efficiency in reducing the dose in the first year; and (2) efficiency in dose reducing at long term

  13. Evaluation of an interdisciplinary re-isolation policy for patients with previous Clostridium difficile diarrhea.

    Science.gov (United States)

    Boone, N; Eagan, J A; Gillern, P; Armstrong, D; Sepkowitz, K A

    1998-12-01

    Diarrhea caused by Clostridium difficile is increasingly recognized as a nosocomial problem. The effectiveness and cost of a new program to decrease nosocomial spread by identifying patients scheduled for readmission who were previously positive for toxin was evaluated. The Memorial Sloan-Kettering Cancer Center is a 410-bed comprehensive cancer center in New York City. Many patients are readmitted during their course of cancer therapy. In 1995 as a result of concern about the nosocomial spread of C difficile, we implemented a policy that all patients who were positive for C difficile toxin in the previous 6 months with no subsequent toxin-negative stool as an outpatient would be placed into contact isolation on readmission pending evaluation of stool specimens. Patients who were previously positive for C difficile toxin were identified to infection control and admitting office databases via computer. Admitting personnel contacted infection control with all readmissions to determine whether a private room was required. Between July 1, 1995, and June 30, 1996, 47 patients who were previously positive for C difficile toxin were readmitted. Before their first scheduled readmission, the specimens for 15 (32%) of these patients were negative for C difficile toxin. They were subsequently cleared as outpatients and were readmitted without isolation. Workup of the remaining 32 patients revealed that the specimens for 7 patients were positive for C difficile toxin and 86 isolation days were used. An additional 25 patients used 107 isolation days and were either cleared after a negative specimen was obtained in-house or discharged without having an appropriate specimen sent. Four patients (9%) had reoccurring C difficile after having toxin-negative stools. We estimate (because outpatient specimens were not collected) the cost incurred at $48,500 annually, including the incremental cost of hospital isolation and equipment. Our policy to control the spread of nosocomial C

  14. The reliability of the Associate Platinum digital foot scanner in measuring previously developed footprint characteristics: a technical note.

    Science.gov (United States)

    Papuga, M Owen; Burke, Jeanmarie R

    2011-02-01

    An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  15. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, C. A. A.; Smilde, A. K.; Doornbos, D. A.

    1993-01-01

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  16. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, CAA; SMILDE, AK; DOORNBOS, DA

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  17. A key performance measures for evaluating cold supply chain performance in farm industry

    Directory of Open Access Journals (Sweden)

    Shashi Shashi

    2015-08-01

    Full Text Available The main objective of this study was to develop a set of measures, evaluate their importance and effect in cold supply chain performance. This investigation reviewed previous research works on all the stages of the farm product supply chain. Based on farm product supply chain, 4 measures with 31 metrics were identified and developed to measure the cold supply chain performance. A survey was organized to establish the importance and the effect of identified measures. The 5 point Likert scale questionnaire was distributed among SC academics and practitioners. The observed finding infers that the measurement instrument was substantiating for evaluating cold supply chain performance in farm industry. The new developed metrics will help firms improve the visibility of supply among partners and in better decision making. The investigation was enfolded up through the plan of direction intended for future study.

  18. SONOGRAPHIC PREDICTION OF SCAR DEHISCENCE IN WOMEN WITH PREVIOUS CAESAREAN SECTION

    Directory of Open Access Journals (Sweden)

    Shubhada Suhas Jajoo

    2018-01-01

    Full Text Available BACKGROUND Caesarean section (Sectio Caesarea is a surgical method for the completion of delivery. After various historical modifications of operative techniques, modern approach consists in the transverse dissection of the anterior wall of the uterus. The rate of vaginal birth after caesarean section was significantly reduced from year to year and the rate of repeated caesarean section is increased during the past 10 years. Evaluation of scar thickness is done by ultrasound, but it is still debatable size of thick scar that would be guiding “cut-off value” for the completion of the delivery method. To better assess the risk of uterine rupture, some authors have proposed sonographic measurement of lower uterine segment thickness near term assuming that there is an inverse correlation between LUS thickness and the risk of uterine scar defect. Therefore, this assessment for the management of women with prior CS may increase safety during labour by selecting women with the lowest risk of uterine rupture. The aim of the study is to study the diagnostic accuracy of sonographic measurements of the Lower Uterine Segment (LUS thickness near term in predicting uterine scar defects in women with prior Caesarean Section (CS. We aim to ascertain the best cut-off values for predicting uterine rupture. MATERIALS AND METHODS 100 antenatal women with history of previous one LSCS who come to attend antenatal clinic will be assessed for scar thickness by transabdominal ultrasonography and its correlation with intraoperative findings. This prospective longitudinal study was conducted for 1 year after IEC approval with inclusion criteria previous one LSCS. Exclusion criteria- 1 Previous myomectomy scar; 2 Previous 2 LSCS; 3 Previous hysterotomy scar. RESULTS Our findings indicate that there is a strong association between degree of LUS thinning measured near term and the risk of uterine scar defect at birth. In our study, optimal cut-off value for predicting

  19. Measuring and evaluating the soft energy efficiency measures. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Suvilehto, H.-M.; Solid, D. [AaF-Industry Ltd, Solna (Sweden); Rouhiainen, V. [Adato Energia Ltd, Helsinki (Finland); Honkasalo, N.; Sarvaranta, A. [AaF-Consult Ltd, Solna (Sweden)

    2012-07-15

    This study discusses how to quantify the energy savings related to the companies' aims to enhance their customers' energy efficiency which is one target in the Action Plan for Energy Services in the Energy Efficiency Agreement for the Industries. In Finland, a majority of the energy utilities have signed this action plan and are providing their customers services to improve their energy efficiency. Dissemination of information is the most widely used service to the customers and it is provided in a number of ways including printed material, annual energy report, and an internet tool to access and report hourly measurements. Some of the internet tools cover electricity, district heat and water. The focus of the study is in the evaluation of 'soft' measures; in other words, those measures given by energy utilities that principally rely on communication instruments. However, monitoring the impact of information and communication is far from easy. Carrying out a properly designed evaluation of programmes aiming on enhanced energy efficiency is difficult. Evaluation of the impact of a magazine article on energy efficiency is even more challenging, costly and therefore also rare. Distribution of information as measure to enhance energy efficiency is an important part of EU.s energy policy but what are the ways and even more so, are there ways to actually quantify these savings? There has been excessive work by the member states and research institutes to find a common and robust methodology within the EU to evaluate and quantify energy savings from technical measures. The ex-ante and ex-post results from these evaluations can however differ considerably, e.g. the expected energy savings from installing air to air heat pumps in Denmark did not deliver the expected energy savings. The problems with finding a common robust methodology become even more visible when the 'soft' measures are put under the evaluation loop. The &apos

  20. External Evaluation Measures for Subspace Clustering

    DEFF Research Database (Denmark)

    Günnemann, Stephan; Färber, Ines; Müller, Emmanuel

    2011-01-01

    research area of subspace clustering. We formalize general quality criteria for subspace clustering measures not yet addressed in the literature. We compare the existing external evaluation methods based on these criteria and pinpoint limitations. We propose a novel external evaluation measure which meets...

  1. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  2. [Patient evaluation and outcome measures].

    Science.gov (United States)

    Nieto Pol, Enrique

    2014-01-01

    Both the initial evaluation and follow-up of patients with osteoarthritis require systematic evaluation of the indicators that provide information on the degree of involvement of the disease and allow its quantification. Reliable measures of disease progression help decision-making by clinicians and provide valid information on treatment response and the effectiveness of the distinct therapeutic interventions. The instruments recommended in research, as outcome measures in osteoarthritis, are pain evaluation, assessment of physical function, and self-reported global evaluation. In studies lasting more than 1 year, structural changes are evaluated through simple X-ray. Self-reported quality of life assessment and physician global assessment are also recommended as options. These indicators should be incorporated into routine clinical practice for adequate evaluation and correct follow-up of patients with osteoarthritis. The recommended pain evaluation method for use in clinical practice is the visual analog scale (VAS). The best instrument to evaluate physical function in patients with hip or knee osteoarthritis is the WOMAC scale (Western Ontario and McMaster Universities Osteoarthritis Index). For patient-reported global assessment in routine practice, the recommended scales are VAS or the SF-12 (12-item short-form health survey). Copyright © 2014 Elsevier España, S.L. All rights reserved.

  3. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans

    2014-01-01

    %) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially...... larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability...... excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57...

  4. Quality measures for nurse practitioner practice evaluation.

    Science.gov (United States)

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  5. Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping—Part 1: Quantification of Thickness Measurement Deviation

    Directory of Open Access Journals (Sweden)

    Hun Yun

    2016-06-01

    Full Text Available Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs. Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

  6. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  7. [Prevalence of previously diagnosed diabetes mellitus in Mexico.

    Science.gov (United States)

    Rojas-Martínez, Rosalba; Basto-Abreu, Ana; Aguilar-Salinas, Carlos A; Zárate-Rojas, Emiliano; Villalpando, Salvador; Barrientos-Gutiérrez, Tonatiuh

    2018-01-01

    To compare the prevalence of previously diagnosed diabetes in 2016 with previous national surveys and to describe treatment and its complications. Mexico's national surveys Ensa 2000, Ensanut 2006, 2012 and 2016 were used. For 2016, logistic regression models and measures of central tendency and dispersion were obtained. The prevalence of previously diagnosed diabetes in 2016 was 9.4%. The increase of 2.2% relative to 2012 was not significant and only observed in patients older than 60 years. While preventive measures have increased, the access to medical treatment and lifestyle has not changed. The treatment has been modified, with an increase in insulin and decrease in hypoglycaemic agents. Population aging, lack of screening actions and the increase in diabetes complications will lead to an increase on the burden of disease. Policy measures targeting primary and secondary prevention of diabetes are crucial.

  8. Evaluation of a titanium dioxide-based DGT technique for measuring inorganic uranium species in fresh and marine waters

    DEFF Research Database (Denmark)

    Hutchins, Colin M.; Panther, Jared G.; Teasdale, Peter R.

    2012-01-01

    A new diffusive gradients in a thin film (DGT) technique for measuring dissolved uranium (U) in freshwater is reported. The new method utilises a previously described binding phase, Metsorb (a titanium dioxide based adsorbent). This binding phase was evaluated and compared to the well-established...

  9. The New Brunswick Laboratory Safeguards Measurement Evaluation Program

    International Nuclear Information System (INIS)

    Cacic, C.G.; Trahey, N.M.; Zook, A.C.

    1987-01-01

    The New Brunswick Laboratory (NBL) has been tasked by the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) to assess and evaluate the adequacy of measurement technology as applied to materials accounting in DOE nuclear facilities. The Safeguards Measurement Evaluation (SME) Program was developed as a means to monitor and evaluate the quality and effectiveness of accounting measurements by site, material balance area (MBA), or unit process. Phase I of the SME Program, initiated during 1985, involved evaluation of the primary accountability measurement methods at six DOE Defense Programs facilities: Savannah River Plant, Portsmouth Gaseous Diffusion Plant, Y-12 Plant, Rocky Flats Plant, Rockwell Hanford Operations, and NBL. Samples of uranyl nitrate solution, dried plutonium nitrates, and plutonium oxides were shipped to the participants for assay and isotopic abundance measurements. Resulting data are presented and evaluated as indicators of current state-of-the-practice accountability measurement methodology, deficiencies in materials accounting practices, and areas for possible assistance in upgrading measurement capabilities. Continuing expansion of the SME Program to include materials which are representative of specific accountability measurement points within the DOE complex is discussed

  10. Evaluating measurement of dynamic constructs: defining a measurement model of derivatives.

    Science.gov (United States)

    Estabrook, Ryne

    2015-03-01

    While measurement evaluation has been embraced as an important step in psychological research, evaluating measurement structures with longitudinal data is fraught with limitations. This article defines and tests a measurement model of derivatives (MMOD), which is designed to assess the measurement structure of latent constructs both for analyses of between-person differences and for the analysis of change. Simulation results indicate that MMOD outperforms existing models for multivariate analysis and provides equivalent fit to data generation models. Additional simulations show MMOD capable of detecting differences in between-person and within-person factor structures. Model features, applications, and future directions are discussed. (c) 2015 APA, all rights reserved).

  11. Corrective measures evaluation report for Tijeras Arroyo groundwater.

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Johnathan L (North Wind, Inc., Idaho Falls, ID); Orr, Brennon R. (North Wind, Inc., Idaho Falls, ID); Dettmers, Dana L. (North Wind, Inc., Idaho Falls, ID); Hall, Kevin A. (North Wind, Inc., Idaho Falls, ID); Howard, M. Hope (North Wind, Inc., Idaho Falls, ID)

    2005-08-01

    This Corrective Measures Evaluation report was prepared as directed by a Compliance Order on Consent issued by the New Mexico Environment Department to document the process of selecting the preferred remedial alternative for Tijeras Arroyo Groundwater. Supporting information includes background concerning the site conditions and potential receptors and an overview of work performed during the Corrective Measures Evaluation. The evaluation of remedial alternatives included identifying and describing four remedial alternatives, an overview of the evaluation criteria and approach, comparing remedial alternatives to the criteria, and selecting the preferred remedial alternative. As a result of the Corrective Measures Evaluation, monitored natural attenuation of the contaminants of concern (trichloroethene and nitrate) is the preferred remedial alternative for implementation as the corrective measure for Tijeras Arroyo Groundwater. Design criteria to meet cleanup goals and objectives and the corrective measures implementation schedule for the preferred remedial alternative are also presented.

  12. The impact of previous knee injury on force plate and field-based measures of balance.

    Science.gov (United States)

    Baltich, Jennifer; Whittaker, Jackie; Von Tscharner, Vinzenz; Nettel-Aguirre, Alberto; Nigg, Benno M; Emery, Carolyn

    2015-10-01

    Individuals with post-traumatic osteoarthritis demonstrate increased sway during quiet stance. The prospective association between balance and disease onset is unknown. Improved understanding of balance in the period between joint injury and disease onset could inform secondary prevention strategies to prevent or delay the disease. This study examines the association between youth sport-related knee injury and balance, 3-10years post-injury. Participants included 50 individuals (ages 15-26years) with a sport-related intra-articular knee injury sustained 3-10years previously and 50 uninjured age-, sex- and sport-matched controls. Force-plate measures during single-limb stance (center-of-pressure 95% ellipse-area, path length, excursion, entropic half-life) and field-based balance scores (triple single-leg hop, star-excursion, unipedal dynamic balance) were collected. Descriptive statistics (mean within-pair difference; 95% confidence intervals) were used to compare groups. Linear regression (adjusted for injury history) was used to assess the relationship between ellipse-area and field-based scores. Injured participants on average demonstrated greater medio-lateral excursion [mean within-pair difference (95% confidence interval); 2.8mm (1.0, 4.5)], more regular medio-lateral position [10ms (2, 18)], and shorter triple single-leg hop distances [-30.9% (-8.1, -53.7)] than controls, while no between group differences existed for the remaining outcomes. After taking into consideration injury history, triple single leg hop scores demonstrated a linear association with ellipse area (β=0.52, 95% confidence interval 0.01, 1.01). On average the injured participants adjusted their position less frequently and demonstrated a larger magnitude of movement during single-limb stance compared to controls. These findings support the evaluation of balance outcomes in the period between knee injury and post-traumatic osteoarthritis onset. Copyright © 2015 Elsevier Ltd. All rights

  13. Performance Evaluation Tests for Environmental Research (PETER): evaluation of 114 measures

    Science.gov (United States)

    Bittner, A. C. Jr; Carter, R. C.; Kennedy, R. S.; Harbeson, M. M.; Krause, M.

    1986-01-01

    The goal of the Performance Evaluation Tests for Environmental Research (PETER) Program was to identify a set of measures of human capabilities for use in the study of environmental and other time-course effects. 114 measures studied in the PETER Program were evaluated and categorized into four groups based upon task stability and task definition. The Recommended category contained 30 measures that clearly obtained total stabilization and had an acceptable level of reliability efficiency. The Acceptable-But-Redundant category contained 15 measures. The 37 measures in the Marginal category, which included an inordinate number of slope and other derived measures, usually had desirable features which were outweighed by faults. The 32 measures in the Unacceptable category had either differential instability or weak reliability efficiency. It is our opinion that the 30 measures in the Recommended category should be given first consideration for environmental research applications. Further, it is recommended that information pertaining to preexperimental practice requirements and stabilized reliabilities should be utilized in repeated-measures environmental studies.

  14. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  15. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  16. Evaluation of the MADAM waste measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-03-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software.

  17. Evaluation of the MADAM waste measurement system

    International Nuclear Information System (INIS)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-01-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software

  18. Evaluation of Human Prehension Using Grasp Quality Measures

    Directory of Open Access Journals (Sweden)

    Beatriz León

    2012-10-01

    Full Text Available One of the main features of the human hand is its grasping ability. Robot grasping has been studied for years and different quality measures have been proposed to evaluate the stability and manipulability of grasps. Although the human hand is obviously more complex than robot hands, the methods used in robotics might be adopted to study the human grasp. The purpose of this work is to propose a set of measures that allow the evaluation of different aspects of the human grasp. The most common robotic grasp quality measures have been adapted to the evaluation of the human hand and a new quality measure – the fatigue index – is proposed in order to incorporate the biomechanical aspect into the evaluation. The minimum set of indices that allows the evaluation of the different aspects of the grasp is obtained from the analysis of a human prehension experiment.

  19. Challenging previous conceptions of vegetarianism and eating disorders.

    Science.gov (United States)

    Fisak, B; Peterson, R D; Tantleff-Dunn, S; Molnar, J M

    2006-12-01

    The purpose of this study was to replicate and expand upon previous research that has examined the potential association between vegetarianism and disordered eating. Limitations of previous research studies are addressed, including possible low reliability of measures of eating pathology within vegetarian samples, use of only a few dietary restraint measures, and a paucity of research examining potential differences in body image and food choice motives of vegetarians versus nonvegetarians. Two hundred and fifty-six college students completed a number of measures of eating pathology and body image, and a food choice motives questionnaire. Interestingly, no significant differences were found between vegetarians and nonvegetarians in measures of eating pathology or body image. However, significant differences in food choice motives were found. Implications for both researchers and clinicians are discussed.

  20. Distance measures for image segmentation evaluation

    OpenAIRE

    Monteiro, Fernando C.; Campilho, Aurélio

    2012-01-01

    In this paper we present a study of evaluation measures that enable the quantification of the quality of an image segmentation result. Despite significant advances in image segmentation techniques, evaluation of these techniques thus far has been largely subjective. Typically, the effectiveness of a new algorithm is demonstrated only by the presentation of a few segmented images and is otherwise left to subjective evaluation by the reader. Such an evaluation criterion can be useful for differ...

  1. DEVELOPMENT AND EVALUATION OF SIMPLE MEASUREMENT SYSTEM USING THE OBLIQUE PHOTO AND DEM

    Directory of Open Access Journals (Sweden)

    H. Nonaka

    2016-06-01

    Full Text Available When a disaster occurs, we must grasp and evaluate its damage as soon as possible. Then we try to estimate them from some kind of photographs, such as surveillance camera imagery, satellite imagery, photographs taken from a helicopter and so on. Especially in initial stage, estimation of decent damage situation for a short time is more important than investigation of damage situation for a long time. One of the source of damage situation is the image taken by surveillance camera, satellite sensor and helicopter. If we can measure any targets in these imagery, we can estimate a length of a lava flow, a reach of a cinder and a sediment volume in volcanic eruption or landslide. Therefore in order to measure various information for a short time, we developed a simplified measurement system which uses these photographs. This system requires DEM in addition to photographs, but it is possible to use previously acquired DEM. To measure an object, we require only two steps. One is the determination of the position and the posture in which the photograph is shot. We determine these parameters using DEM. The other step is the measurement of an object in photograph. In this paper, we describe this system and show the experimental results to evaluate this system. In this experiment we measured the top of Mt. Usu by using two measurement method of this system. Then we can measure it about one hour and the difference between the measurement results and the airborne LiDAR data are less than 10 meter.

  2. EVALUATION ON THE SEISMIC RESPONSE CHARACTERISTICS OF A ROAD EMBANKMENT BASED ON THE MODERATE EARTHQUAKE OBSERVATION AND THE MICROTREMOR MEASUREMENT

    Science.gov (United States)

    Hata, Yoshiya; Ichii, Koji; Yamada, Masayuki; Tokida, Ken-Ichi; Takezawa, Koichiro; Shibao, Susumu; Mitsushita, Junji; Murata, Akira; Furukawa, Aiko; Koizumi, Keigo

    Accurate evaluation on the seismic response characteristics of a road embankment is very important for the rational seismic assessment. However, in a lot of previous studies, the seismic response characteristics of an embankment were evaluated based on the results of shaking table test, centrifuge model test and dynamic FEM analysis. In this study, the transfer function and the shear wave velocity of a road embankment were evaluated based on the in-situ records of moderate earthquake observation and microtremor measurement. Test results show the possibility that the shear wave velocity of an embankment can be estimated by the earthquake observation or the microtremor measurement and the dynamic linear FEM analysis.

  3. Experimental evaluation of a MOSFET dosimeter for proton dose measurements

    International Nuclear Information System (INIS)

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-01-01

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations

  4. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  5. Evaluation of a compact tinnitus therapy by electrophysiological tinnitus decompensation measures.

    Science.gov (United States)

    Low, Yin Fen; Argstatter, Heike; Bolay, Hans Volker; Strauss, Daniel J

    2008-01-01

    Large-scale neural correlates of the tinnitus decompensation have been identified by using wavelet phase stability criteria of single sweep sequences of auditory late responses (ALRs). Our previous work showed that the synchronization stability in ALR sequences might be used for objective quantification of the tinnitus decompensation and attention which link to Jastreboff tinnitus model. In this study, we intend to provide an objective evaluation for quantifying the effect of music therapy in tinnitus patients. We examined neural correlates of the attentional mechanism in single sweep sequences of ALRs in chronic tinnitus patients who underwent compact therapy course by using the maximum entropy auditory paradigm. Results by our measure showed that the extent of differentiation between attended and unattended conditions improved significantly after the therapy. It is concluded that the wavelet phase synchronization stability of ALRs single sweeps can be used for the objective evaluation of tinnitus therapies, in this case the compact tinnitus music therapy.

  6. Corrective measures evaluation report for technical area-v groundwater.

    Energy Technology Data Exchange (ETDEWEB)

    Witt, Johnathan L (North Wind, Inc., Idaho Falls, ID); Orr, Brennon R. (North Wind, Inc., Idaho Falls, ID); Dettmers, Dana L. (North Wind, Inc., Idaho Falls, ID); Hall, Kevin A. (North Wind, Inc., Idaho Falls, ID); Howard, Hope (North Wind, Inc., Idaho Falls, ID)

    2005-07-01

    This Corrective Measures Evaluation Report was prepared as directed by the Compliance Order on Consent issued by the New Mexico Environment Department to document the process of selecting the preferred remedial alternative for contaminated groundwater at Technical Area V. Supporting information includes background information about the site conditions and potential receptors and an overview of work performed during the Corrective Measures Evaluation. Evaluation of remedial alternatives included identification and description of four remedial alternatives, an overview of the evaluation criteria and approach, qualitative and quantitative evaluation of remedial alternatives, and selection of the preferred remedial alternative. As a result of the Corrective Measures Evaluation, it was determined that monitored natural attenuation of all contaminants of concern (trichloroethene, tetrachloroethene, and nitrate) was the preferred remedial alternative for implementation as the corrective measure to remediate contaminated groundwater at Technical Area V of Sandia National Laboratories/New Mexico. Finally, design criteria to meet cleanup goals and objectives and the corrective measures implementation schedule for the preferred remedial alternative are presented.

  7. Prospective evaluation of patient-reported quality-of-life outcomes following SBRT ± cetuximab for locally-recurrent, previously-irradiated head and neck cancer

    International Nuclear Information System (INIS)

    Vargo, John A.; Heron, Dwight E.; Ferris, Robert L.; Rwigema, Jean-Claude M.; Wegner, Rodney E.; Kalash, Ronny; Ohr, James; Kubicek, Greg J.; Burton, Steven

    2012-01-01

    Purpose: Stereotactic body radiotherapy (SBRT) has emerged as a promising salvage strategy for unresectable, previously-irradiated recurrent squamous cell carcinomas of the head and neck (rSCCHN). Here-in, we report the first prospective evaluation of patient-reported quality-of-life (PR-QoL) following re-irradiation with SBRT ± cetuximab for rSCCHN. Materials and methods: From November 2004 to May 2011, 150 patients with unresectable, rSCCHN in a previously-irradiated field receiving >40 Gy were treated with SBRT to 40–50 Gy in 5 fractions ± concurrent cetuximab. PR-QoL was prospectively acquired using University of Washington Quality-of-Life Revised (UW-QoL-R). Results: Overall PR-QoL, health-related PR-QoL, and select domains commonly affected by re-irradiation progressively increase following an initial 1-month decline with statistically significant improvements noted in swallowing (p = 0.025), speech (p = 0.017), saliva (p = 0.041), activity (p = 0.032) and recreation (p = 0.039). Conclusions: Especially for patients surviving >1-year, improved tumor control associated with SBRT re-irradiation may ameliorate decreased PR-QoL resulting from rSCCHN. These improvements in PR-QoL transcend all measured domains in a validated PR-QoL assessment tool independent of age, use of cetuximab, tumor volume, and interval since prior irradiation.

  8. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  9. Evaluation the effectiveness of remote blood pressure monitoring technology in patients with hypertension on the basis of clinical recommendations performance measures

    Directory of Open Access Journals (Sweden)

    Posnenkova O.M.

    2015-06-01

    Material and Methods ― Remote BP monitoring was organized on the basis of computer system which automatically in text messages send requests about BP level to Htn patients. Obtained BP results were stored in the system and automatically worked. A doctor corrected a patient’s therapy if necessary based on this information. To evaluate the effectiveness of a new technology one year observation of 97 Htn patients was organized (54.6% – male aged 49±11 years. Patients regularly responded to automated SMS requests the computer system about the level of blood pressure. The effectiveness was evaluated with the help of the following hypertension guidelines performance measures: 1 a part of patients with four or more BP results during the previous 12 months; 2 a part of patients with BP above the goal level who prescribed two or more antihypertensive drugs on the last visit during the previous 12 months; 3 a part of patients with BP above the goal level 140/90 mm Hg who prescribed two or more antihypertensive drugs on the last visit during the previous 12 months; 4 a part of patients with goal blood pressure (less than 140/90 mmHg on the last visit during the previous 12 months. To evaluate a performance of these measures before BP monitoring the data extracted from patients’ ambulatory cards were used. Results ― 62 patients completed one-year BP monitoring A part of patients with four or more BP results during the previous 12 months increased from 21% to 100% (p<0.001. From 70% to 82% increased the part of patients who were prescribed two or more antihypertensive drugs (p=0.091. From 31% to 15% reduced the part of hypertensives with uncontrolled BP who were prescribed less than two antihypertensive drugs on the last visit (p=0.044. After one-year monitoring a goal BP was registered in 77% of Htn patients versus 13% at the start of the observation (p<0.001. Conclusion ― Htn guidelines performance measures allowed evaluate quantitatively the positive influence

  10. Subsequent pregnancy outcome after previous foetal death

    NARCIS (Netherlands)

    Nijkamp, J. W.; Korteweg, F. J.; Holm, J. P.; Timmer, A.; Erwich, J. J. H. M.; van Pampus, M. G.

    Objective: A history of foetal death is a risk factor for complications and foetal death in subsequent pregnancies as most previous risk factors remain present and an underlying cause of death may recur. The purpose of this study was to evaluate subsequent pregnancy outcome after foetal death and to

  11. Evaluating measurement uncertainty in fluid phase equilibrium calculations

    Science.gov (United States)

    van der Veen, Adriaan M. H.

    2018-04-01

    The evaluation of measurement uncertainty in accordance with the ‘Guide to the expression of uncertainty in measurement’ (GUM) has not yet become widespread in physical chemistry. With only the law of the propagation of uncertainty from the GUM, many of these uncertainty evaluations would be cumbersome, as models are often non-linear and require iterative calculations. The methods from GUM supplements 1 and 2 enable the propagation of uncertainties under most circumstances. Experimental data in physical chemistry are used, for example, to derive reference property data and support trade—all applications where measurement uncertainty plays an important role. This paper aims to outline how the methods for evaluating and propagating uncertainty can be applied to some specific cases with a wide impact: deriving reference data from vapour pressure data, a flash calculation, and the use of an equation-of-state to predict the properties of both phases in a vapour-liquid equilibrium. The three uncertainty evaluations demonstrate that the methods of GUM and its supplements are a versatile toolbox that enable us to evaluate the measurement uncertainty of physical chemical measurements, including the derivation of reference data, such as the equilibrium thermodynamical properties of fluids.

  12. Direct Heat-Flux Measurement System (MDF) for Solar central Receiver Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ballestrin, J.

    2001-07-01

    A direct flux measurement system, MDF, has been designed, constructed and mounted on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA) in addition to an indirect flux measurement system based on a CCD camera. It's one of the main future objectives to compare systematically both measurements of the concentrated solar power, increasing in this way the confidence in the estimate of this quantity. Today everything is prepared to perform the direct flux measurement on the aperture of solar receivers: calorimeter array, data acquisition system and software. the geometry of the receiver determines the operation and analysis procedures to obtain the indecent power onto the defined area. The study of previous experiences with direct flux measurement systems ha been useful to define a new simpler and more accurate system. A description of each component of the MDF system is included, focusing on the heat-flux sensors or calorimeters, which enables these measurements to be done in a few seconds without water-cooling. The incident solar power and the spatial flux distribution on the aperture of the volumetric receiver Hitrec II are supplied by the above-mentioned MDF system. The first results obtained during the evaluation of this solar receiver are presented including a sunrise-sunset test. All these measurements have been concentrated in one coefficient that describes the global behavior of the Solar Power Plant. (Author) 18 refs.

  13. Measuring pregnancy planning: A psychometric evaluation and comparison of two scales.

    Science.gov (United States)

    Drevin, Jennifer; Kristiansson, Per; Stern, Jenny; Rosenblad, Andreas

    2017-11-01

    To psychometrically test the London Measure of Unplanned Pregnancy and compare it with the Swedish Pregnancy Planning Scale. The incidence of unplanned pregnancies is an important indicator of reproductive health. The London Measure of Unplanned Pregnancy measures pregnancy planning by taking contraceptive use, timing, intention to become pregnant, desire for pregnancy, partner agreement, and pre-conceptual preparations into account. It has, however, previously not been psychometrically evaluated using confirmatory factor analysis. The Likert-scored single-item Swedish Pregnancy Planning Scale has been developed to measure the woman's own view of pregnancy planning level. Cross-sectional design. In 2012-2013, 5493 pregnant women living in Sweden were invited to participate in the Swedish Pregnancy Planning study, of whom 3327 (61%) agreed to participate and answered a questionnaire. A test-retest pilot study was conducted in 2011-2012. Thirty-two participants responded to the questionnaire on two occasions 14 days apart. Data were analysed using confirmatory factor analysis, Cohen's weighted kappa and Spearman's correlation. All items of the London Measure of Unplanned Pregnancy contributed to measuring pregnancy planning, but four items had low item-reliability. The London Measure of Unplanned Pregnancy and Swedish Pregnancy Planning Scale corresponded reasonably well with each other and both showed good test-retest reliability. The London Measure of Unplanned Pregnancy may benefit from item reduction and its usefulness may be questioned. The Swedish Pregnancy Planning Scale is time-efficient and shows acceptable reliability and construct validity, which makes it more useful for measuring pregnancy planning. © 2017 John Wiley & Sons Ltd.

  14. Evaluation of local site effect from microtremor measurements in Babol City, Iran

    Science.gov (United States)

    Rezaei, Sadegh; Choobbasti, Asskar Janalizadeh

    2018-03-01

    Every year, numerous casualties and a large deal of financial losses are incurred due to earthquake events. The losses incurred by an earthquake vary depending on local site effect. Therefore, in order to conquer drastic effects of an earthquake, one should evaluate urban districts in terms of the local site effect. One of the methods for evaluating the local site effect is microtremor measurement and analysis. Aiming at evaluation of local site effect across the city of Babol, the study area was gridded and microtremor measurements were performed with an appropriate distribution. The acquired data was analyzed through the horizontal-to-vertical noise ratio (HVNR) method, and fundamental frequency and associated amplitude of the H/V peak were obtained. The results indicate that fundamental frequency of the study area is generally lower than 1.25 Hz, which is acceptably in agreement with the findings of previous studies. Also, in order to constrain and validate the seismostratigraphic model obtained with this method, the results were compared with geotechnical, geological, and seismic data. Comparing the results of different methods, it was observed that the presented geophysical method can successfully determine the values of fundamental frequency across the study area as well as local site effect. Using the data obtained from the analysis of microtremor, a microzonation map of fundamental frequency across the city of Babol was prepared. This map has numerous applications in designing high-rise building and urban development plans.

  15. Abiraterone in metastatic prostate cancer without previous chemotherapy

    NARCIS (Netherlands)

    Ryan, Charles J.; Smith, Matthew R.; de Bono, Johann S.; Molina, Arturo; Logothetis, Christopher J.; de Souza, Paul; Fizazi, Karim; Mainwaring, Paul; Piulats, Josep M.; Ng, Siobhan; Carles, Joan; Mulders, Peter F. A.; Basch, Ethan; Small, Eric J.; Saad, Fred; Schrijvers, Dirk; van Poppel, Hendrik; Mukherjee, Som D.; Suttmann, Henrik; Gerritsen, Winald R.; Flaig, Thomas W.; George, Daniel J.; Yu, Evan Y.; Efstathiou, Eleni; Pantuck, Allan; Winquist, Eric; Higano, Celestia S.; Taplin, Mary-Ellen; Park, Youn; Kheoh, Thian; Griffin, Thomas; Scher, Howard I.; Rathkopf, Dana E.; Boyce, A.; Costello, A.; Davis, I.; Ganju, V.; Horvath, L.; Lynch, R.; Marx, G.; Parnis, F.; Shapiro, J.; Singhal, N.; Slancar, M.; van Hazel, G.; Wong, S.; Yip, D.; Carpentier, P.; Luyten, D.; de Reijke, T.

    2013-01-01

    Abiraterone acetate, an androgen biosynthesis inhibitor, improves overall survival in patients with metastatic castration-resistant prostate cancer after chemotherapy. We evaluated this agent in patients who had not received previous chemotherapy. In this double-blind study, we randomly assigned

  16. Operational Contract Support: Economic Impact Evaluation and Measures of Effectiveness

    Science.gov (United States)

    2017-12-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA MBA PROFESSIONAL REPORT OPERATIONAL CONTRACT SUPPORT: ECONOMIC IMPACT EVALUATION AND MEASURES...DATES COVERED MBA professional report 4. TITLE AND SUBTITLE OPERATIONAL CONTRACT SUPPORT: ECONOMIC IMPACT EVALUATION AND MEASURES OF EFFECTIVENESS 5...evaluation, expeditionary economics , operational contract support, measure of effectiveness 15. NUMBER OF PAGES 89 16. PRICE CODE 17. SECURITY

  17. Measures to Evaluate the Effects of DBS on Speech Production

    Science.gov (United States)

    Weismer, Gary; Yunusova, Yana; Bunton, Kate

    2011-01-01

    The purpose of this paper is to review and evaluate measures of speech production that could be used to document effects of Deep Brain Stimulation (DBS) on speech performance, especially in persons with Parkinson disease (PD). A small set of evaluative criteria for these measures is presented first, followed by consideration of several speech physiology and speech acoustic measures that have been studied frequently and reported on in the literature on normal speech production, and speech production affected by neuromotor disorders (dysarthria). Each measure is reviewed and evaluated against the evaluative criteria. Embedded within this review and evaluation is a presentation of new data relating speech motions to speech intelligibility measures in speakers with PD, amyotrophic lateral sclerosis (ALS), and control speakers (CS). These data are used to support the conclusion that at the present time the slope of second formant transitions (F2 slope), an acoustic measure, is well suited to make inferences to speech motion and to predict speech intelligibility. The use of other measures should not be ruled out, however, and we encourage further development of evaluative criteria for speech measures designed to probe the effects of DBS or any treatment with potential effects on speech production and communication skills. PMID:24932066

  18. The Impact of a Developed Measurement and Evaluation Development Program on Pre-Service Physical Education Teachers' Perceptions Related to Measurement and Evaluation

    Science.gov (United States)

    Arslan, Yunus; Erturan Ilker, Gokce; Demirhan, Giyasettin

    2013-01-01

    The purpose of this study was to investigate the impact of the Measurement and Evaluation Development Program on pre-service physical education teachers' general perceptions and competency perceptions related to alternative assessment in physical education, and their competency perceptions related to educational measurement and evaluation. The…

  19. How to Measure Coach Burnout: An Evaluation of Three Burnout Measures

    Science.gov (United States)

    Lundkvist, Erik; Stenling, Andreas; Gustafsson, Henrik; Hassmén, Peter

    2014-01-01

    Although coach burnout has been studied for 30 years, what measure to use in this context has not yet been problematized. This study focuses on evaluating convergent and discriminant validity of three coach burnout measures by using multi-trait/multi-method analysis (CT-C[M-1]) model. We choose Maslach Burnout Inventory (MBI), the two dimensional…

  20. Peer Evaluation Can Reliably Measure Local Knowledge

    Science.gov (United States)

    Reyes-García, Victoria; Díaz-Reviriego, Isabel; Duda, Romain; Fernández-Llamazares, Álvaro; Gallois, Sandrine; Guèze, Maximilien; Napitupulu, Lucentezza; Pyhälä, Aili

    2016-01-01

    We assess the consistency of measures of individual local ecological knowledge obtained through peer evaluation against three standard measures: identification tasks, structured questionnaires, and self-reported skills questionnaires. We collected ethnographic information among the Baka (Congo), the Punan (Borneo), and the Tsimane' (Amazon) to…

  1. Evaluation and proposal of improvement for the measurement system in ATLAS

    International Nuclear Information System (INIS)

    Cho, Dong Woo; Kim, Jong Rok; Park, Jun Kwon

    2007-03-01

    The project independently evaluated the validities and reliability of measurement system in ATLAS, then proposed plans to improve the measurement system from evaluated results. For this objectives, we evaluated the design, technical backgrounds, verifying data of measurement system in ATLAS. From this evaluation, we proposed plans for improvement on parts which need improvement

  2. Evaluating measurement accuracy a practical approach

    CERN Document Server

    Rabinovich, Semyon G

    2017-01-01

    This book presents a systematic and comprehensive exposition of the theory of measurement accuracy and provides solutions that fill significant and long-standing gaps in the classical theory. It eliminates the shortcomings of the classical theory by including methods for estimating accuracy of single measurements, the most common type of measurement. The book also develops methods of reduction and enumeration for indirect measurements, which do not require Taylor series and produce a precise solution to this problem. It produces grounded methods and recommendations for summation of errors. The monograph also analyzes and critiques two foundation metrological documents, the International Vocabulary of Metrology (VIM) and the Guide to the Expression of Uncertainty in Measurement (GUM), and discusses directions for their revision. This new edition adds a step-by-step guide on how to evaluate measurement accuracy and recommendations on how to calculate systematic error of multiple measurements. There is also an e...

  3. Evaluating measurement accuracy a practical approach

    CERN Document Server

    Rabinovich, Semyon G

    2013-01-01

    The goal of Evaluating Measurement Accuracy: A Practical Approach is to present methods for estimating the accuracy of measurements performed in industry, trade, and scientific research. From developing the theory of indirect measurements to proposing new methods of reduction, transformation, and enumeration, this work encompasses the full range of measurement data processing. It includes many examples that illustrate the application of general theory to typical problems encountered in measurement practice. As a result, the book serves as an inclusive reference work for data processing of all types of measurements: single and multiple, combined and simultaneous, direct (both linear and nonlinear), and indirect (both dependent and independent). It is a working tool for experimental scientists and engineers of all disciplines who work with instrumentation. It is also a good resource for natural science and engineering students and for technicians performing measurements in industry. A key feature of the book is...

  4. Usage of performance measurement and evaluation systems : the impact of evaluator characteristics

    OpenAIRE

    Gelderman, Maarten

    1998-01-01

    This paper discusses the relation between characteristics of the evaluating manager and the way performance measurement and evaluation information is used. First a discussion is provided about the dependent variable. It is recognized that categorization into archetypes (e.g., evaluative styles) is unsatisfactory. Instead the information content/emphasis dimensions financial-non- financial, quantitative-qualitative, process-outcome, past-future and external-internal, along with the dimension f...

  5. Handbook on Measurement, Assessment, and Evaluation in Higher Education

    Science.gov (United States)

    Secolsky, Charles, Ed.; Denison, D. Brian, Ed.

    2011-01-01

    Increased demands for colleges and universities to engage in outcomes assessment for accountability purposes have accelerated the need to bridge the gap between higher education practice and the fields of measurement, assessment, and evaluation. The "Handbook on Measurement, Assessment, and Evaluation in Higher Education" provides higher…

  6. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  7. Development of a measure of student self-evaluation of physics exam performance

    Science.gov (United States)

    Hagedorn, Eric Anthony

    The central purpose of this study was to provide preliminary evidence of the reliability and validity of the SEVSI - P (Self- evaluation scaled instrument - physics). This instrument, designed to measure student self-evaluation of physics exam performance, was developed in congruence with social cognitive theory. Self-evaluation in this study is defined to consist of two of the three subprocesses of self-regulation: self-observation and judgmental process. As such, the SEVSI - P consists of two subscales, one measuring the frequency and types of self-observations made during a physics exam and one measuring the frequency and types of judgmental comparisons made after an exam. Data from 621 completed surveys, voluntarily taken by first semester algebra/trigonometry based physics students at six Midwestern universities and one Southern university, were analyzed for reliability and factorial validity. Cronbach alphas of .71 and .83 for the self-observation and judgment subscales, respectively, indicate acceptable reliability for the instrument. Confirmatory factor analysis indicates the acceptability of the hypothesis that the data analyzed could have indeed been obtained from the proposed two factor model (self-observation and judgment). The results of this confirmatory factor analysis provide preliminary construct validity for this instrument. A number of theoretically related items were included on the SEVSI - P form to elicity information about the use of goals and pre-planned strategies, actions taken in response to previous poor performances, and emotional responses to performance. A correlational analysis of these items along with the self-observation and judgment subscale scores provided a limited degree of convergent validity for the two subscales. Analyses of variance were done to determine the presence of differences in scoring patterns based on gender or reported ethnic origin. These results indicate slightly higher judgment subscale scores for women and

  8. Measurement and evaluation of sustainable development

    International Nuclear Information System (INIS)

    Kondyli, Julia

    2010-01-01

    This paper develops a methodology to analyse, measure and evaluate sustainable development (SD). A holistic approach (systems analysis) is applied to operationalise the SD concept and an integrated approach (composite indicator construction) is adopted for the measurement of SD. The operationalisation of the SD concept is based on an in-depth systems analysis of issues associated with economic, social and environmental problems in a policy context. The composite indicator (overall sustainability index) is developed based on the three composite sub-indicators of the SD dimensions. The valuation of the SD is based both on the aggregated sub-indicators and the overall composite indicator. The methodology is used to evaluate the SD of the North Aegean islands between different temporal points. The assessment of the change in the islands' SD is based on a quartile grading scale of the overall SD composite scores.

  9. Dosimetry with alanine/electron spin resonance. Measuring and evaluating

    International Nuclear Information System (INIS)

    Anton, M.

    2007-02-01

    In the first part of the present report a short outline of the theoretical foundations in view of the parameters and evaluation programs described in the following is given. The second part described the measurement procedures and the handling of the measuring data including the applied data formats. In the third part the collection SPAD of MATLAB programs is described, which are necessary for the processing of the measurment data and the subsequent evaluations. Routine evaluations can by means of the present graphic user surface simply be performed. But the described routines can (and shall) be used also as kit in order to solve special evaluation problems. The third part closes with a listing of all programs including the online available aid texts. All functions were tested both under MATLAB 6 and under MATLAB 7

  10. Noise evaluation of a point autofocus surface topography measuring instrument

    Science.gov (United States)

    Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard

    2018-06-01

    In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.

  11. Magnetization measurement of niobium for superconducting cavity material evaluation

    International Nuclear Information System (INIS)

    Wake, Masayoshi; Saito, Kenji.

    1995-05-01

    A series of magnetization measurements on niobium materials for superconducting cavities was performed, and the method was found to be very useful for material evaluation. The effects of annealing, chemical polishing and machining were clearly observed by this method. The material quality and the processing of the material can be properly evaluated by measuring the magnetization. An observation of the Q-disease effect indicates the possibility of using this method for the studies beyond material evaluation. (J.P.N)

  12. Contact pressure measurement in hand tool evaluation studies

    NARCIS (Netherlands)

    Kuijt-Evers, L.F.M.; Bosch, T.

    2006-01-01

    In hand tool evaluation studies, several objective measurements are used. Grip force distribution and grip force are important as they give feedback about the force which has to be performed with the hand on the handle. A measurement technique -which is related to grip force measurement- is contact

  13. Evaluation of protection measurements for urban environments; Avaliacao de medidas de protecao para ambientes urbanos

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R., E-mail: erochedo@cnen.gov.b [Comissao Nacional de Energia Nuclear (CODIN/CNEN), Rio de Janeiro, RJ (Brazil). Coord. de Instalacoes Nucleares; Silva, Diogo N.G.; Nascimento, Udilma; Conti, Luiz F., E-mail: dneves@ird.gov.b, E-mail: lfcconti@ird.gov.b, E-mail: udilma@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica V., E-mail: maria.wasserman@pq.cnpq.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    Radioactive accidents has shown the necessity of a previous evaluation planning of exposure and directives for implementation of protection measurements. The description or measurements in the literature usually is associated to reduction of concentrations in the medium where they are applied. For verification the efficiency in dose reduction, it is necessary to proceed simulations. Through the development of data base on protection measurements, it was established basic sceneries, typically tropical as far the building type is concerned and the construction material. The program SIEM was used for simulation of contamination with {sup 137}Cs. The results indicates that generic solutions persuade not to and the decision make processes should be effectuated according to the real conditions of contamination and the use of affected area. For affected areas, two classification criteria were defined: (1) efficiency in reducing the dose in the first year; and (2) efficiency in dose reducing at long term

  14. Measurement and evaluation of human factor training in nuclear power plants

    International Nuclear Information System (INIS)

    Hamasaki, Kenichi

    2006-01-01

    The purpose of this study is to measure and evaluate the effectiveness of human factor training aimed at awareness and behavioral changes, conducted by electric power company for the nuclear power plant staff. As the first step, the researcher investigated recent trends in training measurement and evaluation methods in the United States. It was found that many instances of training measurement/evaluation had been reported, and that the ROI model was the mainstream method for such measurement and evaluation. However, there had been no instances reported in which the effectiveness of human factor training for plant staff had been measured. The researcher therefore developed a new questionnaire-type of effectiveness measurement/evaluation method, based on the framework of the ROI model. Two-years of research was then conducted, in which the effectiveness of a human factor training program was measured using the newly developed method. This research revealed that participants' overall satisfaction and knowledge/skill acquisition levels were high. The percentage of participants who demonstrated awareness/behavioral change after returning to the workplace increased from 50% at first measurement to 81% at second measurement. It can therefore be concluded that the effectiveness of the second training is greater than that of the first training. Use of the new effectiveness measurement/evaluation method will enable quantification of human factor training effectiveness and help improve training quality. (author)

  15. Temperature measurement and control system for transtibial prostheses: Single subject clinical evaluation.

    Science.gov (United States)

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza

    2018-01-01

    The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.

  16. Implant breast reconstruction after salvage mastectomy in previously irradiated patients.

    Science.gov (United States)

    Persichetti, Paolo; Cagli, Barbara; Simone, Pierfranco; Cogliandro, Annalisa; Fortunato, Lucio; Altomare, Vittorio; Trodella, Lucio

    2009-04-01

    The most common surgical approach in case of local tumor recurrence after quadrantectomy and radiotherapy is salvage mastectomy. Breast reconstruction is the subsequent phase of the treatment and the plastic surgeon has to operate on previously irradiated and manipulated tissues. The medical literature highlights that breast reconstruction with tissue expanders is not a pursuable option, considering previous radiotherapy a contraindication. The purpose of this retrospective study is to evaluate the influence of previous radiotherapy on 2-stage breast reconstruction (tissue expander/implant). Only patients with analogous timing of radiation therapy and the same demolitive and reconstructive procedures were recruited. The results of this study prove that, after salvage mastectomy in previously irradiated patients, implant reconstruction is still possible. Further comparative studies are, of course, advisable to draw any conclusion on the possibility to perform implant reconstruction in previously irradiated patients.

  17. Evaluation of a survey tool to measure safety climate in Australian hospital pharmacy staff.

    Science.gov (United States)

    Walpola, Ramesh L; Chen, Timothy F; Fois, Romano A; Ashcroft, Darren M; Lalor, Daniel J

    Safety climate evaluation is increasingly used by hospitals as part of quality improvement initiatives. Consequently, it is necessary to have validated tools to measure changes. To evaluate the construct validity and internal consistency of a survey tool to measure Australian hospital pharmacy patient safety climate. A 42 item cross-sectional survey was used to evaluate the patient safety climate of 607 Australian hospital pharmacy staff. Survey responses were initially mapped to the factor structure previously identified in European community pharmacy. However, as the data did not adequately fit the community pharmacy model, participants were randomly split into two groups with exploratory factor analysis performed on the first group (n = 302) and confirmatory factor analyses performed on the second group (n = 305). Following exploratory factor analysis (59.3% variance explained) and confirmatory factor analysis, a 6-factor model containing 28 items was obtained with satisfactory model fit (χ 2 (335) = 664.61 p  0.643) and model nesting between the groups (Δχ 2 (22) = 30.87, p = 0.10). Three factors (blame culture, organisational learning and working conditions) were similar to those identified in European community pharmacy and labelled identically. Three additional factors (preoccupation with improvement; comfort to question authority; and safety issues being swept under the carpet) highlight hierarchical issues present in hospital settings. This study has demonstrated the validity of a survey to evaluate patient safety climate of Australian hospital pharmacy staff. Importantly, this validated factor structure may be used to evaluate changes in safety climate over time. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears.

    Science.gov (United States)

    Cha, Kyoung Ha; Jensen, Gary C; Balijepalli, Anant S; Cohan, Bruce E; Meyerhoff, Mark E

    2014-02-04

    Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 μM glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/μM and a limit of quantitation (LOQ) of 9 μM. The strips also exhibit ≤13% error (n = 3) for 25, 50, and 75 μM glucose in the presence of 10 μM acetaminophen, 100 μM ascorbic acid, and 100 μM uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 μM (mean = 47 μM, median = 43 μM), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.

  19. The grey relational approach for evaluating measurement uncertainty with poor information

    International Nuclear Information System (INIS)

    Luo, Zai; Wang, Yanqing; Zhou, Weihu; Wang, Zhongyu

    2015-01-01

    The Guide to the Expression of Uncertainty in Measurement (GUM) is the master document for measurement uncertainty evaluation. However, the GUM may encounter problems and does not work well when the measurement data have poor information. In most cases, poor information means a small data sample and an unknown probability distribution. In these cases, the evaluation of measurement uncertainty has become a bottleneck in practical measurement. To solve this problem, a novel method called the grey relational approach (GRA), different from the statistical theory, is proposed in this paper. The GRA does not require a large sample size or probability distribution information of the measurement data. Mathematically, the GRA can be divided into three parts. Firstly, according to grey relational analysis, the grey relational coefficients between the ideal and the practical measurement output series are obtained. Secondly, the weighted coefficients and the measurement expectation function will be acquired based on the grey relational coefficients. Finally, the measurement uncertainty is evaluated based on grey modeling. In order to validate the performance of this method, simulation experiments were performed and the evaluation results show that the GRA can keep the average error around 5%. Besides, the GRA was also compared with the grey method, the Bessel method, and the Monte Carlo method by a real stress measurement. Both the simulation experiments and real measurement show that the GRA is appropriate and effective to evaluate the measurement uncertainty with poor information. (paper)

  20. Using measurements for evaluation of black carbon modeling

    Directory of Open Access Journals (Sweden)

    S. Gilardoni

    2011-01-01

    Full Text Available The ever increasing use of air quality and climate model assessments to underpin economic, public health, and environmental policy decisions makes effective model evaluation critical. This paper discusses the properties of black carbon and light attenuation and absorption observations that are the key to a reliable evaluation of black carbon model and compares parametric and nonparametric statistical tools for the quantification of the agreement between models and observations. Black carbon concentrations are simulated with TM5/M7 global model from July 2002 to June 2003 at four remote sites (Alert, Jungfraujoch, Mace Head, and Trinidad Head and two regional background sites (Bondville and Ispra. Equivalent black carbon (EBC concentrations are calculated using light attenuation measurements from January 2000 to December 2005. Seasonal trends in the measurements are determined by fitting sinusoidal functions and the representativeness of the period simulated by the model is verified based on the scatter of the experimental values relative to the fit curves. When the resolution of the model grid is larger than 1° × 1°, it is recommended to verify that the measurement site is representative of the grid cell. For this purpose, equivalent black carbon measurements at Alert, Bondville and Trinidad Head are compared to light absorption and elemental carbon measurements performed at different sites inside the same model grid cells. Comparison of these equivalent black carbon and elemental carbon measurements indicates that uncertainties in black carbon optical properties can compromise the comparison between model and observations. During model evaluation it is important to examine the extent to which a model is able to simulate the variability in the observations over different integration periods as this will help to identify the most appropriate timescales. The agreement between model and observation is accurately described by the overlap of

  1. EVALUATION OF A POPULAR SHOPPING MALL BUILT TO ACCOMMODATE PREVIOUS STREET VENDORS IN DOWNTOWN PORTO ALEGRE

    Directory of Open Access Journals (Sweden)

    Naiana Maura John

    2016-04-01

    Full Text Available The objective of this paper is to evaluate a popular shopping mall, named the CPC, focusing on its location, use, aesthetics and security. The global and local integration values of streets surrounding the CPC and the former Square XV Camelódromo are compared in order to evidence their level of accessibility. Concerning use, the following specific objectives are investigated: retailers’ and CPC users’ preference for a popular shopping mall type and CPC users’ knowledge and shopping routines in the former Square XV Camelódromo; retailers’ and CPC users’ levels of satisfaction with the CPC, evaluations of the CPC building and shops location regarding sales, assessments of the existence of a food court and a bus terminal in the CPC building. In relation to aesthetics, retailers’ and CPC users’ evaluations of the internal appearance of the CPC, and retailers’, CPC users’ and architects’ assessments of the external appearance of the CPC are revealed. Moreover, retailers’ and CPC users’ evaluations of security in the bus terminal in the CPC building and in downtown Porto Alegre are identified. Data gathering methods included archival surveys, physical measurements, behavioral observations, and questionnaires. Data were analyzed through non-parametric statistical tests and space syntax methods. Results corroborate findings of other studies regarding the need for movement of people and visibility of shops at ground level, in order to achieve a satisfactory sales performance. Moreover, the CPC external appearance tends to be differently evaluated among retailers, CPC users and architects.

  2. Development and initial evaluation of an enhanced measure of boundary flexibility for the work and family domains.

    Science.gov (United States)

    Matthews, Russell A; Barnes-Farrell, Janet L

    2010-07-01

    This manuscript reports the development of a measure of work and family domain boundary flexibility. Building on previous research, we propose an expanded definition of boundary flexibility that includes two components-flexibility-ability and flexibility-willingness-and we develop a measure designed to capture this more comprehensive definition of boundary flexibility. Flexibility-ability is conceptualized as an individual's perception of personal and situational constraints that affect boundary management, and flexibility-willingness is conceptualized as an individual difference variable that captures the motivation to engage in boundary flexing. An additional feature of domain boundaries, permeability, is also examined. Data are presented from two studies. Study 1 (N = 244) describes the development of a multiscale measure that extends current conceptual definitions of boundary flexibility. Study 2 (N = 225) describes the refinement and evaluation of this measure. Confirmatory factor analysis, reliability evidence, interscale correlations, and correlations with important work-family constructs (e.g., domain centrality, work-family conflict) provide initial construct validity evidence for the measure.

  3. Evaluating and measuring impact: where and how?

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    On 12 and 13 November, a workshop on “Evaluation in international organisations” took place at CERN. Fourteen internal auditors and planning and policy analysts, from six different international organisations, discussed whether and how to evaluate the impact of their organisations’ programmes on the target beneficiaries.      Participants of the “Evaluation in international organisations” workshop at CERN. “Evaluation”, a relatively recent but fast growing discipline, deals with the systematic and objective assessment of the impact of policies and programmes on the target beneficiaries – often society at large. In the past few years, other international organisations have created an evaluation function within their internal structure, whose role is to measure the impact of their public policies. “In the first instance we wanted to understand what the difference between evaluation a...

  4. Evaluation of different field methods for measuring soil water infiltration

    Science.gov (United States)

    Pla-Sentís, Ildefonso; Fonseca, Francisco

    2010-05-01

    Soil infiltrability, together with rainfall characteristics, is the most important hydrological parameter for the evaluation and diagnosis of the soil water balance and soil moisture regime. Those balances and regimes are the main regulating factors of the on site water supply to plants and other soil organisms and of other important processes like runoff, surface and mass erosion, drainage, etc, affecting sedimentation, flooding, soil and water pollution, water supply for different purposes (population, agriculture, industries, hydroelectricity), etc. Therefore the direct measurement of water infiltration rates or its indirect deduction from other soil characteristics or properties has become indispensable for the evaluation and modelling of the previously mentioned processes. Indirect deductions from other soil characteristics measured under laboratory conditions in the same soils, or in other soils, through the so called "pedo-transfer" functions, have demonstrated to be of limited value in most of the cases. Direct "in situ" field evaluations have to be preferred in any case. In this contribution we present the results of past experiences in the measurement of soil water infiltration rates in many different soils and land conditions, and their use for deducing soil water balances under variable climates. There are also presented and discussed recent results obtained in comparing different methods, using double and single ring infiltrometers, rainfall simulators, and disc permeameters, of different sizes, in soils with very contrasting surface and profile characteristics and conditions, including stony soils and very sloping lands. It is concluded that there are not methods universally applicable to any soil and land condition, and that in many cases the results are significantly influenced by the way we use a particular method or instrument, and by the alterations in the soil conditions by the land management, but also due to the manipulation of the surface

  5. Formation evaluation using measurements recorded while drilling

    International Nuclear Information System (INIS)

    Coope, D.F.; Hendricks, W.E.

    1984-01-01

    Two of the measurements recorded while drilling (MWD), gamma ray and resistivity, are traditionally formation evaluation measurements. However, their primary user thus far has been the drilling engineer. The authors believe that MWD will have increasing importance in formation evaluation, and that a good understanding of MWD resistivity and gamma ray logs will be needed by the log analyst. MWD gamma ray and resistivity logs are similar to their wireline counterparts, but there are significant differences. The differences stem from different invasion (or lack of invasion) development for MWD as opposed to open hole wireline; drill collar influence on both the resistivity and gamma ray (GR) measurements - this influence is both positive and negative; and logging speed (drilling rate for MWD) is much slower for MWD and can vary erratically. The MWD logs presented in this paper demonstrate the value of using MWD logs. Emphasis is placed on both the qualitative and quantitative techniques available to the log analyst to help him get maximum benefit from the MWD logs

  6. Approximate Bayesian evaluations of measurement uncertainty

    Science.gov (United States)

    Possolo, Antonio; Bodnar, Olha

    2018-04-01

    The Guide to the Expression of Uncertainty in Measurement (GUM) includes formulas that produce an estimate of a scalar output quantity that is a function of several input quantities, and an approximate evaluation of the associated standard uncertainty. This contribution presents approximate, Bayesian counterparts of those formulas for the case where the output quantity is a parameter of the joint probability distribution of the input quantities, also taking into account any information about the value of the output quantity available prior to measurement expressed in the form of a probability distribution on the set of possible values for the measurand. The approximate Bayesian estimates and uncertainty evaluations that we present have a long history and illustrious pedigree, and provide sufficiently accurate approximations in many applications, yet are very easy to implement in practice. Differently from exact Bayesian estimates, which involve either (analytical or numerical) integrations, or Markov Chain Monte Carlo sampling, the approximations that we describe involve only numerical optimization and simple algebra. Therefore, they make Bayesian methods widely accessible to metrologists. We illustrate the application of the proposed techniques in several instances of measurement: isotopic ratio of silver in a commercial silver nitrate; odds of cryptosporidiosis in AIDS patients; height of a manometer column; mass fraction of chromium in a reference material; and potential-difference in a Zener voltage standard.

  7. Laboratory Evaluation of Low-Cost Wearable Sensors for Measuring Head Impacts in Sports.

    Science.gov (United States)

    Tyson, Abigail M; Duma, Stefan M; Rowson, Steven

    2018-04-03

    Advances in low-cost wearable head impact sensor technology provide potential benefits regarding sports safety for both consumers and researchers. However, previous laboratory evaluations are not directly comparable and don't incorporate test conditions representative of unhelmeted impacts. This study addresses those limitations. The xPatch by X2 Biosystems and the SIM-G by Triax Technologies were placed on a NOCSAE headform with a Hybrid III neck which underwent impacts tests using a pendulum. Impact conditions included helmeted, padded impactor to bare head, and rigid impactor to bare head to represent long and short-duration impacts seen in helmeted and unhelmeted sports. The wearable sensors were evaluated on their kinematic accuracy by comparing results to reference sensors located at the headform center of gravity. Statistical tests for equivalence were performed on the slope of the linear regression between wearable sensors and reference. The xPatch gave equivalent measurements to the reference in select longer-duration impacts whereas the SIM-G had large variance leading to no equivalence. For the short-duration impacts, both wearable sensors underpredicted the reference. This error can be improved with increases in sampling rate from 1 to 1.5 kHz. Follow-up evaluations should be performed on the field to identify error in vivo. (197/200).

  8. Difficulties in the evaluation and measuring of soil water infiltration

    Science.gov (United States)

    Pla-Sentís, Ildefonso

    2013-04-01

    Soil water infiltration is the most important hydrological parameter for the evaluation and diagnosis of the soil water balance and soil moisture regime. Those balances and regimes are the main regulating factors of the on site water supply to plants and other soil organisms and of other important processes like runoff, surface and mass erosion, drainage, etc, affecting sedimentation, flooding, soil and water pollution, water supply for different purposes (population, agriculture, industries, hydroelectricity), etc. Therefore the evaluation and measurement of water infiltration rates has become indispensable for the evaluation and modeling of the previously mentioned processes. Infiltration is one of the most difficult hydrological parameters to evaluate or measure accurately. Although the theoretical aspects of the process of soil water infiltration are well known since the middle of the past century, when several methods and models were already proposed for the evaluation of infiltration, still nowadays such evaluation is not frequently enough accurate for the purposes being used. This is partially due to deficiencies in the methodology being used for measuring infiltration, including some newly proposed methods and equipments, and in the use of non appropriate empirical models and approaches. In this contribution we present an analysis and discussion about the main difficulties found in the evaluation and measurement of soil water infiltration rates, and the more commonly committed errors, based on the past experiences of the author in the evaluation of soil water infiltration in many different soils and land conditions, and in their use for deducing soil water balances under variable and changing climates. It is concluded that there are not models or methods universally applicable to any soil and land condition, and that in many cases the results are significantly influenced by the way we use a particular method or instrument, and by the alterations in the soil

  9. BOOK REVIEW: Evaluating the Measurement Uncertainty: Fundamentals and practical guidance

    Science.gov (United States)

    Lira, Ignacio

    2003-08-01

    Evaluating the Measurement Uncertainty is a book written for anyone who makes and reports measurements. It attempts to fill the gaps in the ISO Guide to the Expression of Uncertainty in Measurement, or the GUM, and does a pretty thorough job. The GUM was written with the intent of being applicable by all metrologists, from the shop floor to the National Metrology Institute laboratory; however, the GUM has often been criticized for its lack of user-friendliness because it is primarily filled with statements, but with little explanation. Evaluating the Measurement Uncertainty gives lots of explanations. It is well written and makes use of many good figures and numerical examples. Also important, this book is written by a metrologist from a National Metrology Institute, and therefore up-to-date ISO rules, style conventions and definitions are correctly used and supported throughout. The author sticks very closely to the GUM in topical theme and with frequent reference, so readers who have not read GUM cover-to-cover may feel as if they are missing something. The first chapter consists of a reprinted lecture by T J Quinn, Director of the Bureau International des Poids et Mesures (BIPM), on the role of metrology in today's world. It is an interesting and informative essay that clearly outlines the importance of metrology in our modern society, and why accurate measurement capability, and by definition uncertainty evaluation, should be so important. Particularly interesting is the section on the need for accuracy rather than simply reproducibility. Evaluating the Measurement Uncertainty then begins at the beginning, with basic concepts and definitions. The third chapter carefully introduces the concept of standard uncertainty and includes many derivations and discussion of probability density functions. The author also touches on Monte Carlo methods, calibration correction quantities, acceptance intervals or guardbanding, and many other interesting cases. The book goes

  10. The impact of previous leaders on the evaluation of new leaders: an alternative to prototype matching.

    Science.gov (United States)

    Ritter, Barbara A; Lord, Robert G

    2007-11-01

    In 2 studies, this research demonstrated the existence of leader transference, a cognitive process whereby mental representations of previous leaders are activated and used for evaluation when new, similar leaders are encountered. The 1st study demonstrated that exposure to a new leader who was similar to a past leader led to erroneous generalization of leader characteristics and associated underlying attributions. The 2nd study showed that expectations of just treatment and abuse were also subject to transfer from old to new, similar leaders, although positive and negative affective responses were not. Results suggested that individuals exposed to a leader who was not reminiscent of an old leader were more likely to use a general leader prototype to form leader expectations, whereas individuals exposed to a leader who was similar to an old leader activated a significant other mental representation for use in making judgments. These results have implications for individual- and relational-level processes as characterized by implicit leadership theory and leader-member exchange theory as well as macro theories of leader succession and organizational culture change. (c) 2007 APA

  11. Performance Evaluation and Measurement of the Organization in Strategic Analysis and Control: Methodological Aspects

    OpenAIRE

    Živan Ristić; Neđo Balaban

    2006-01-01

    Information acquired by measuring and evaluation are a necessary condition for good decision-making in strategic management. This work deals with : (a) Methodological aspects of evaluation (kinds of evaluation, metaevaluation) and measurement (supposition of isomorphism in measurement, kinds and levels of measurement, errors in measurement and the basic characteristics of measurement) (b) Evaluation and measurement of potential and accomplishments of the organization in Kaplan-Norton perspect...

  12. Measuring Health Literacy in Individuals with Diabetes: A Systematic Review and Evaluation of Available Measures

    Science.gov (United States)

    Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A.

    2013-01-01

    Objective: To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. Methods" A systematic literature review…

  13. Good Evaluation Measures: More than Their Psychometric Properties

    Science.gov (United States)

    Weitzman, Beth C.; Silver, Diana

    2013-01-01

    In this commentary, we examine Braverman's insights into the trade-offs between feasibility and rigor in evaluation measures and reject his assessment of the trade-off as a zero-sum game. We, argue that feasibility and policy salience are, like reliability and validity, intrinsic to the definition of a good measure. To reduce the tension between…

  14. Nuclear Measurements, Evaluations and Applications (NEMEA-7) Collaborative International Evaluated Library Organisation (CIELO). Workshop Proceedings

    International Nuclear Information System (INIS)

    Chadwick, Mark; Plompen, Arjan; ); Emmeric Dupont; )

    2014-01-01

    The 7. workshop on Nuclear Measurements, Evaluations and Applications (NEMEA) focused on international collaboration in nuclear data by hosting the kick-off meeting of the pilot project of the Collaborative International Evaluated Library Organisation (CIELO). CIELO aims at fostering nuclear data advances by using the joint expertise of the nuclear data community under the auspices of the OECD Nuclear Energy Agency. The workshop aimed at status reviews of planned and completed contributions and related developments for the CIELO pilot isotopes. The workshop further sought to facilitate in-depth discussions on nuclear data issues which are being addressed in the framework of European Commission projects like ERINDA, EUFRAT, ANDES and CHANDA. The 7. workshop on Nuclear Measurements, Evaluations and Applications (NEMEA) provided an opportunity for the Collaborative International Evaluated Library Organisation (CIELO) to meet and advance its objectives to improve our understanding of neutron reactions on key isotopes that are especially important in nuclear applications, especially in the area of criticality safety and reactors. CIELO is focusing initially on six nuclides ( 1 H, 16 O, 56 Fe, 235 U, 238 U and 239 Pu). These nuclides are important in the aforementioned applications, and despite decades of work many open questions remain to be solved. In some cases, the existing evaluations need improvement because the underlying experimental measurements are either lacking or contradictory. In other cases, nuclear theory work is needed to better advance predictions. In yet other cases, information from cross-section measurements is proving difficult to reconcile with information from integral nuclear criticality experiments or neutron shielding experiments. The main challenges to be faced are as follows: For oxygen, new work is needed to better define the total and elastic cross-sections at lower energies and neutron scattering angular distributions. An outstanding

  15. An environmental impact measure for nuclear fuel cycle evaluation

    International Nuclear Information System (INIS)

    Ahn, Joonhong

    2004-01-01

    Review of the models and measures for repository performance assessment has revealed that dedicated measures for environmental impacts need to be developed for the purpose of nuclear-fuel-cycle evaluation from the viewpoint of environmental impact minimization. The present study proposes the total toxicity index of released radionuclides that have accumulated in the region exterior to the repository as an environmental impact measure. The measure is quantitatively evaluated by a radionuclide transport model that incorporates the effects of canister-array configuration and the initial mass loading in the waste canister. With the measure, it is demonstrated that the environmental impact of the repository can be effectively reduced by reduction of the initial mass loading and change in the canister-array configuration in the repository. Environmental impacts of the mill tailings and the depleted uranium are as important as those from the high-level radioactive wastes repository. For a fair comparison of various fuel cycles, the sum of these impacts should be compared. (author)

  16. Legibility Evaluation Using Point-of-regard Measurement

    Science.gov (United States)

    Saito, Daisuke; Saito, Keiichi; Saito, Masao

    Web site visibility has become important because of the rapid dissemination of World Wide Web, and combinations of foreground and background colors are crucial in providing high visibility. In our previous studies, the visibilities of several web-safe color combinations were examined using a psychological method. In those studies, simple stimuli were used because of experimental restriction. In this paper, legibility of sentences on web sites was examined using a psychophisiological method, point-of-regard measurement, to obtain other practical data. Ten people with normal color sensations ranging from ages 21 to 29 were recruited. The number of characters per line in each page was arranged in the same number, and the four representative achromatic web-safe colors, that is, #000000, #666666, #999999 and #CCCCCC, were examined. The reading time per character and the gaze time per line were obtained from point-of-regard measurement, and the normalized with the reading time and the gaze time of the three colors were calculated and compared. As the results, it was shown that the time of reading and gaze become long at the same ratio when the contrast decreases by point-of-regard measurement. Therefore, it was indicated that the legibility of color combinations could be estimated by point-of-regard measurement.

  17. A systematic approach to the modelling of measurements for uncertainty evaluation

    International Nuclear Information System (INIS)

    Sommer, K D; Weckenmann, A; Siebert, B R L

    2005-01-01

    The evaluation of measurement uncertainty is based on both, the knowledge about the measuring process and the quantities which influence the measurement result. The knowledge about the measuring process is represented by the model equation which expresses the interrelation between the measurand and the input quantities. Therefore, the modelling of the measurement is a key element of modern uncertainty evaluation. A modelling concept has been developed that is based on the idea of the measuring chain. It gets on with only a few generic model structures. From this concept, a practical stepwise procedure has been derived

  18. Error evaluation method for material accountancy measurement. Evaluation of random and systematic errors based on material accountancy data

    International Nuclear Information System (INIS)

    Nidaira, Kazuo

    2008-01-01

    International Target Values (ITV) shows random and systematic measurement uncertainty components as a reference for routinely achievable measurement quality in the accountancy measurement. The measurement uncertainty, called error henceforth, needs to be periodically evaluated and checked against ITV for consistency as the error varies according to measurement methods, instruments, operators, certified reference samples, frequency of calibration, and so on. In the paper an error evaluation method was developed with focuses on (1) Specifying clearly error calculation model, (2) Getting always positive random and systematic error variances, (3) Obtaining probability density distribution of an error variance and (4) Confirming the evaluation method by simulation. In addition the method was demonstrated by applying real data. (author)

  19. Non-intrusive measurement of emission indices. A new approach to the evaluation of infrared spectra emitted by aircraft engine exhaust gases

    Energy Technology Data Exchange (ETDEWEB)

    Lindermeir, E.; Haschberger, P.; Tank, V. [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Wessling (Germany). Inst. fuer Optoelektronik

    1997-12-31

    A non-intrusive method is used to determine the emission indices of a research aircraft`s engine in-flight. The principle is based on the Fourier Transform Infrared Spectrometer MIROR which was specifically designed and built for operation aboard aircrafts. This device measures the spectrum of the infrared radiation emitted by the hot exhaust gas under cruise conditions. From these spectra mixing ratios and emission indices can be derived. An extension to previously applied evaluation schemes is proposed: Whereas formerly the plume was assumed a homogeneous layer of gas, temperature and concentration profiles are now introduced to the evaluation procedure. (author) 5 refs.

  20. Evaluation Framework EFI for Measuring the Impact of Learning, Education and Training

    NARCIS (Netherlands)

    Stracke, Christian M.

    2016-01-01

    This article introduces the Evaluation Framework EFI for the Impact Measurement of learning, education and training: The Evaluation Framework for Impact Measurement was developed for specifying the evaluation phase and its objectives and tasks within the IDEAL Reference Model for the introduction

  1. Neurally based measurement and evaluation of environmental noise

    CERN Document Server

    Soeta, Yoshiharu

    2015-01-01

    This book deals with methods of measurement and evaluation of environmental noise based on an auditory neural and brain-oriented model. The model consists of the autocorrelation function (ACF) and the interaural cross-correlation function (IACF) mechanisms for signals arriving at the two ear entrances. Even when the sound pressure level of a noise is only about 35 dBA, people may feel annoyed due to the aspects of sound quality. These aspects can be formulated by the factors extracted from the ACF and IACF. Several examples of measuring environmental noise—from outdoor noise such as that of aircraft, traffic, and trains, and indoor noise such as caused by floor impact, toilets, and air-conditioning—are demonstrated. According to the noise measurement and evaluation, applications for sound design are discussed. This book provides an excellent resource for students, researchers, and practitioners in a wide range of fields, such as the automotive, railway, and electronics industries, and soundscape, architec...

  2. Evaluating groundwater flow using passive electrical measurements

    Science.gov (United States)

    Voytek, E.; Revil, A.; Singha, K.

    2016-12-01

    Accurate quantification of groundwater flow patterns, both in magnitude and direction, is a necessary component of evaluating any hydrologic system. Groundwater flow patterns are often determined using a dense network of wells or piezometers, which can be limited due to logistical or regulatory constraints. The self-potential (SP) method, a passive geophysical technique that relies on currents generated by water movement through porous materials, is a re-emerging alternative or addition to traditional piezometer networks. Naturally generated currents can be measured as voltage differences at the ground surface using only two electrodes, or a more complex electrode array. While the association between SP measurements and groundwater flow was observed as early as 1890s, the method has seen resurgence in hydrology since the governing equations were refined in the 1980s. The method can be used to analyze hydrologic processes at various temporal and spatial scales. Here we present the results of multiple SP surveys collected a multiple scales (1 to 10s of meters). Here single SP grid surveys are used to evaluate flow patterns through artic hillslopes at a discrete point in time. Additionally, a coupled groundwater and electrical model is used to analyze multiple SP data sets to evaluate seasonal changes in groundwater flow through an alpine meadow.

  3. Evaluating the uncertainty of input quantities in measurement models

    Science.gov (United States)

    Possolo, Antonio; Elster, Clemens

    2014-06-01

    The Guide to the Expression of Uncertainty in Measurement (GUM) gives guidance about how values and uncertainties should be assigned to the input quantities that appear in measurement models. This contribution offers a concrete proposal for how that guidance may be updated in light of the advances in the evaluation and expression of measurement uncertainty that were made in the course of the twenty years that have elapsed since the publication of the GUM, and also considering situations that the GUM does not yet contemplate. Our motivation is the ongoing conversation about a new edition of the GUM. While generally we favour a Bayesian approach to uncertainty evaluation, we also recognize the value that other approaches may bring to the problems considered here, and focus on methods for uncertainty evaluation and propagation that are widely applicable, including to cases that the GUM has not yet addressed. In addition to Bayesian methods, we discuss maximum-likelihood estimation, robust statistical methods, and measurement models where values of nominal properties play the same role that input quantities play in traditional models. We illustrate these general-purpose techniques in concrete examples, employing data sets that are realistic but that also are of conveniently small sizes. The supplementary material available online lists the R computer code that we have used to produce these examples (stacks.iop.org/Met/51/3/339/mmedia). Although we strive to stay close to clause 4 of the GUM, which addresses the evaluation of uncertainty for input quantities, we depart from it as we review the classes of measurement models that we believe are generally useful in contemporary measurement science. We also considerably expand and update the treatment that the GUM gives to Type B evaluations of uncertainty: reviewing the state-of-the-art, disciplined approach to the elicitation of expert knowledge, and its encapsulation in probability distributions that are usable in

  4. Severe radiation morbidity in carcinoma of the cervix: impact of pretherapy surgical staging and previous surgery

    International Nuclear Information System (INIS)

    Fine, Bruce A.; Hempling, Ronald E.; Piver, M. Steven; Baker, Trudy R.; McAuley, Michael; Driscoll, Deborah

    1995-01-01

    Purpose: The purpose of this study is to delineate the factors which (a) contribute to an increase in the severe, radiation induced complication rate and (b) have a significant effect on survival in patients with International Federation of Gynecologists and Obstetricians (FIGO) Stage I-IVA cervical cancer undergoing pretherapy surgical staging. Methods and Materials: From 1971-1991, 189 patients underwent pretherapy surgical staging via a retroperitoneal approach (67) or transperitoneal approach (122). Seventy-nine patients had previously experienced a laparotomy. Patients subsequently received a median of 85 Gy to point A. In patients receiving paraaortic radiation, a median of 45 Gy was administered. One hundred and thirty-two (69.8%) patients received hydroxyurea as a radiation sensitizer. Results: Pretherapy surgical evaluation revealed that 21 of 89 (23.6%) Stage II patients and 32 of 85 (37.6%) Stage III patients had paraaortic lymph node metastases. Multivariate logistic regression analysis detailed the significant factors favorably influencing the radiation-induced complication rate to be a retroperitoneal approach of pretherapy surgical staging and no previous laparotomy. Survival was significantly prolonged in patients receiving hydroxyurea, evaluated via a retroperitoneal incision, with negative paraaortic lymph nodes, and with an early stage of disease. Conclusion: A retroperitoneal approach to pretherapy surgical staging and absence of previous surgery reduced the incidence of subsequent radiation-induced complications. Despite improvements in the detection of occult disease, prolonged survival is impaired when the therapeutic measures currently available are used

  5. The Simplest Evaluation Measures for XML Information Retrieval that Could Possibly Work

    NARCIS (Netherlands)

    Hiemstra, Djoerd; Mihajlovic, V.

    2005-01-01

    This paper reviews several evaluation measures developed for evaluating XML information retrieval (IR) systems. We argue that these measures, some of which are currently in use by the INitiative for the Evaluation of XML Retrieval (INEX), are complicated, hard to understand, and hard to explain to

  6. Use of polarization measurements in evaluating cascade contributions to optical excitation functions

    International Nuclear Information System (INIS)

    McConkey, J.W.

    1981-01-01

    Recent developments in theory and experimental measurements of rotational line polarization fractions of diatomic molecules following electron impact are used to show how in some instances cascade free optical excitation functions can be derived without additional measurements of the cascading contribution. The Lyman system of H 2 is presented as an example and some previously conflicting excitation cross-section measurements obtained by different techniques are reconciled

  7. Left ventricular asynergy score as an indicator of previous myocardial infarction

    International Nuclear Information System (INIS)

    Backman, C.; Jacobsson, K.A.; Linderholm, H.; Osterman, G.

    1986-01-01

    Sixty-eight patients with coronary heart disease (CHD) i.e. a hisotry of angina of effort and/or previous 'possible infarction' were examined inter alia with ECG and cinecardioangiography. A system of scoring was designed which allowed a semiquantitative estimate of the left ventricular asynergy from cinecardioangiography - the left ventricular motion score (LVMS). The LVMS was associated with the presence of a previous myocardial infarction (MI), as indicated by the history and ECG findings. The ECG changes specific for a previous MI were associated with high LVMS values and unspecific or absent ECG changes with low LVMS values. Decision thresholds for ECG changes and asynergy in diagnosing a previous MI were evaluated by means of a ROC analysis. The accuracy of ECG in detecting a previous MI was slightly higher when asynergy indicated a 'true MI' than when autopsy result did so in a comparable group. Therefore the accuracy of asynergy (LVMS ≥ 1) in detecting a previous MI or myocardial fibrosis in patients with CHD should be at least comparable with that of autopsy (scar > 1 cm). (orig.)

  8. Bank performance evaluation using dynamic DEA A slacks-based measure approach

    Directory of Open Access Journals (Sweden)

    Morteza Shafiee

    2013-12-01

    Full Text Available Data envelopment analysis (DEA has been applied in many studies in the banking industry but deficiency of empirical studies in Iranian banking sector that incorporate time factor into the efficiency, have still remained. Previous studies measured the efficiency of bank branches in a single period within cross-sectional data. They did not considered effect of interconnecting activities (links between two consecutive terms. The main contribution of this paper is to evaluate the efficiency of an Iranian bank using dynamic SBM model in DEA during three consecutive terms considering net profit as a good link and loan losses as a bad link. In order to realize most important variables (inputs-outputs, relative to our case, we made a checklist and distributed them among headmen of branches and arranged an interview with the CEO of bank. Dynamic SBM efficiency is compared with its static efficiency to check the validity of described model. In addition, input-bad link excesses and output-good link shortfalls (slacks are analyzed and further suggestions to the management are provided.

  9. Measuring societal effects of transdisciplinary research projects: design and application of an evaluation method.

    Science.gov (United States)

    Walter, Alexander I; Helgenberger, Sebastian; Wiek, Arnim; Scholz, Roland W

    2007-11-01

    Most Transdisciplinary Research (TdR) projects combine scientific research with the building of decision making capacity for the involved stakeholders. These projects usually deal with complex, societally relevant, real-world problems. This paper focuses on TdR projects, which integrate the knowledge of researchers and stakeholders in a collaborative transdisciplinary process through structured methods of mutual learning. Previous research on the evaluation of TdR has insufficiently explored the intended effects of transdisciplinary processes on the real world (societal effects). We developed an evaluation framework for assessing the societal effects of transdisciplinary processes. Outputs (measured as procedural and product-related involvement of the stakeholders), impacts (intermediate effects connecting outputs and outcomes) and outcomes (enhanced decision making capacity) are distinguished as three types of societal effects. Our model links outputs and outcomes of transdisciplinary processes via the impacts using a mediating variables approach. We applied this model in an ex post evaluation of a transdisciplinary process. 84 out of 188 agents participated in a survey. The results show significant mediation effects of the two impacts "network building" and "transformation knowledge". These results indicate an influence of a transdisciplinary process on the decision making capacity of stakeholders, especially through social network building and the generation of knowledge relevant for action.

  10. High Titers of Chlamydia trachomatis Antibodies in Brazilian Women with Tubal Occlusion or Previous Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    A. C. S. Machado

    2007-01-01

    Full Text Available Objective. To evaluate serum chlamydia antibody titers (CATs in tubal occlusion or previous ectopic pregnancy and the associated risk factors. Methods. The study population consisted of 55 women wih tubal damage and 55 parous women. CAT was measured using the whole-cell inclusion immunofluorescence test and cervical chlamydial DNA detected by PCR. Odds ratios were calculated to assess variables associated with C. trachomatis infection. Results. The prevalence of chlamydial antibodies and antibody titers in women with tubal occlusion or previous ectopic pregnancy was significantly higher (P<.01 than in parous women. Stepwise logistic regression analysis showed that chlamydia IgG antibodies were associated with tubal damage and with a larger number of lifetime sexual partners. Conclusions. Chlamydia antibody titers were associated with tubal occlusion, prior ectopic pregnancy, and with sexual behavior, suggesting that a chlamydia infection was the major contributor to the tubal damage in these women.

  11. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    Science.gov (United States)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  12. Measuring and evaluating energy consumption in street lighting networks

    International Nuclear Information System (INIS)

    Janiga, P.; Gasparovsky, D.

    2012-01-01

    Smart metering and smart grid are incoming technologies that provide new opportunities in various fields. In connection with the issue of evaluation of the energy aspects of public lighting networks opens up the possibility of evaluating and measuring consumption. Based on the obtained values would be possible to determine energy consumption of lighting systems. This obtained value could serve as a basis for comparing the relevant networks and thus the optimality assessment of lighting designs. Currently, the measure placed in the switchboard of public lighting. If we have considered sections parametramim same lighting, it is necessary to obtain more value from the measured or determined to assess the consumption of time. Proposal of such methods is still under construction but the basic methods have already been outlined. (Authors)

  13. ATLANTIC DIP: simplifying the follow-up of women with previous gestational diabetes.

    LENUS (Irish Health Repository)

    Noctor, E

    2013-11-01

    Previous gestational diabetes (GDM) is associated with a significant lifetime risk of type 2 diabetes. In this study, we assessed the performance of HbA1c and fasting plasma glucose (FPG) measurements against that of 75 g oral glucose tolerance testing (OGTT) for the follow-up screening of women with previous GDM.

  14. Earthquake Ground Motion Measures for Seismic Response Evaluation of Structures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, In-Kil; Ahn, Seong-Moon; Choun, Young-Sun; Seo, Jeong-Moon

    2007-03-15

    This study used the assessment results of failure criteria - base shear, story drift, top acceleration and top displacement - for a PSC containment building subjected to 30 sets of near-fault ground motions to evaluate the earthquake ground motion intensity measures. Seven intensity measures, peak ground acceleration(PGA), peak ground velocity(PGV), spectral acceleration(Sa), velocity(Sv), spectrum intensity for acceleration(SIa), velocity(SIv) and displacement(SId), were used to represent alternative ground motion. The regression analyses of the failure criteria for a PSC containment building were carried out to evaluate a proper intensity measure by using two regression models and seven ground motion parameters. The regression analysis results demonstrate the correlation coefficients of the failure criteria in terms of the candidate IM. From the results, spectral acceleration(Sa) is estimated as the best parameter for a evaluation of the structural safety for a seismic PSA.

  15. What role does measuring medication compliance play in evaluating the efficacy of naltrexone?

    Science.gov (United States)

    Baros, Alicia M; Latham, Patricia K; Moak, Darlene H; Voronin, Konstantin; Anton, Raymond F

    2007-04-01

    Compliance with medication in pharmacotherapy trials of alcoholism has been shown to be equal to, or more, important than in other areas of medicine. Research has suggested that naltrexone's effectiveness can be greatly influenced by the compliance of participants in clinical trials. Presently, we compare 2 compliance measurement methods [urine riboflavin and medication event monitoring system (MEMS)] used simultaneously to evaluate naltrexone's efficacy and the impact of compliance on the size of observable treatment effects. One hundred and thirty-seven of 160 randomized alcoholic patients completed 12-weeks (84 days) of naltrexone or placebo and cognitive behavioral therapy (CBT) or motivational enhancement therapy (MET). Urine riboflavin was determined during study weeks 2, 6, and 12. The MEMS provided a detailed computerized record of when a participant opened their medication bottle throughout the trial. Baseline predictors of MEMS (80% openings) and urine riboflavin (>or=1,500 ng/mL by fluorimetry) compliance were examined. The effects of the treatments in the compliant participants defined by one, the other, or both methods were compared and contrasted with a previously reported intent-to-treat analysis where compliance was not taken into account. Age was predictive of compliance. 105 participants were deemed compliant via urine riboflavin criteria, 87 via MEMS, and 77 when both criteria were met, with no significant differences between treatment groups. The most compliant participants showed a significant medication by therapy interaction. Those treated with naltrexone/CBT showed more abstinence days (pcompliance measurement methods. Compliance measurement does appear to influence the evaluation of the efficacy of naltrexone within the context of CBT. Treatment effect sizes approximately doubled in the most compliant individuals. Measuring compliance by either of 2 distinct methods provides approximately similar results. As compliance with naltrexone

  16. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takemi; Tonoike, Kotaro; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The authors participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the authors derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose by the evaluation formula to the measured value by the alanine dosimeter was 0.94 and the formula agreed within 6%. From examination of this TRACY, we can conclude that the value reported to OECD/NEA has equivalent accuracy. (author)

  17. Urethrotomy has a much lower success rate than previously reported.

    Science.gov (United States)

    Santucci, Richard; Eisenberg, Lauren

    2010-05-01

    We evaluated the success rate of direct vision internal urethrotomy as a treatment for simple male urethral strictures. A retrospective chart review was performed on 136 patients who underwent urethrotomy from January 1994 through March 2009. The Kaplan-Meier method was used to analyze stricture-free probability after the first, second, third, fourth and fifth urethrotomy. Patients with complex strictures (36) were excluded from the study for reasons including previous urethroplasty, neophallus or previous radiation, and 24 patients were lost to followup. Data were available for 76 patients. The stricture-free rate after the first urethrotomy was 8% with a median time to recurrence of 7 months. For the second urethrotomy stricture-free rate was 6% with a median time to recurrence of 9 months. For the third urethrotomy stricture-free rate was 9% with a median time to recurrence of 3 months. For procedures 4 and 5 stricture-free rate was 0% with a median time to recurrence of 20 and 8 months, respectively. Urethrotomy is a popular treatment for male urethral strictures. However, the performance characteristics are poor. Success rates were no higher than 9% in this series for first or subsequent urethrotomy during the observation period. Most of the patients in this series will be expected to experience failure with longer followup and the expected long-term success rate from any (1 through 5) urethrotomy approach is 0%. Urethrotomy should be considered a temporizing measure until definitive curative reconstruction can be planned. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of gene-expression clustering via mutual information distance measure

    Directory of Open Access Journals (Sweden)

    Maimon Oded

    2007-03-01

    Full Text Available Abstract Background The definition of a distance measure plays a key role in the evaluation of different clustering solutions of gene expression profiles. In this empirical study we compare different clustering solutions when using the Mutual Information (MI measure versus the use of the well known Euclidean distance and Pearson correlation coefficient. Results Relying on several public gene expression datasets, we evaluate the homogeneity and separation scores of different clustering solutions. It was found that the use of the MI measure yields a more significant differentiation among erroneous clustering solutions. The proposed measure was also used to analyze the performance of several known clustering algorithms. A comparative study of these algorithms reveals that their "best solutions" are ranked almost oppositely when using different distance measures, despite the found correspondence between these measures when analysing the averaged scores of groups of solutions. Conclusion In view of the results, further attention should be paid to the selection of a proper distance measure for analyzing the clustering of gene expression data.

  19. Systematic content evaluation and review of measurement properties of questionnaires for measuring self-reported fatigue among older people.

    Science.gov (United States)

    Egerton, Thorlene; Riphagen, Ingrid I; Nygård, Arnhild J; Thingstad, Pernille; Helbostad, Jorunn L

    2015-09-01

    The assessment of fatigue in older people requires simple and user-friendly questionnaires that capture the phenomenon, yet are free from items indistinguishable from other disorders and experiences. This study aimed to evaluate the content, and systematically review and rate the measurement properties of self-report questionnaires for measuring fatigue, in order to identify the most suitable questionnaires for older people. This study firstly involved identification of questionnaires that purport to measure self-reported fatigue, and evaluation of the content using a rating scale developed for the purpose from contemporary understanding of the construct. Secondly, for the questionnaires that had acceptable content, we identified studies reporting measurement properties and rated the methodological quality of those studies according to the COSMIN system. Finally, we extracted and synthesised the results of the studies to give an overall rating for each questionnaire for each measurement property. The protocol was registered with PROSPERO (CRD42013005589). Of the 77 identified questionnaires, twelve were selected for review after content evaluation. Methodological quality varied, and there was a lack of information on measurement error and responsiveness. The PROMIS-Fatigue item bank and short forms perform the best. The FACIT-Fatigue scale, Parkinsons Fatigue Scale, Perform Questionnaire, and Uni-dimensional Fatigue Impact Scale also perform well and can be recommended. Minor modifications to improve performance are suggested. Further evaluation of unresolved measurement properties, particularly with samples including older people, is needed for all the recommended questionnaires.

  20. Evaluating the effects of parking policy measures in nature areas

    NARCIS (Netherlands)

    Beunen, R.; Jaarsma, C.F.; Regnerus, H.D.

    2006-01-01

    Parking policy measures are widely used to manage cars in nature areas. Only with data from long-term monitoring projects is it possible to separate ¿normal¿ fluctuation in the number of cars from fluctuation caused by trends or caused by the effects of these measures. An evaluation of measures

  1. Evaluation of the 11CO2 positron emission tomographic method for measuring brain pH. I. pH changes measured in states of altered PCO2

    International Nuclear Information System (INIS)

    Buxton, R.B.; Alpert, N.M.; Babikian, V.; Weise, S.; Correia, J.A.; Ackerman, R.H.

    1987-01-01

    The 11 CO 2 method for measuring local brain pH with positron emission tomography (PET) has been experimentally evaluated, testing the adequacy of the kinetic model and the ability of the method to measure changes in brain pH. Plasma and tissue time/activity curves measured during and following continuous inhalation of 11 CO 2 were fit with a kinetic model that includes effects of tissue pH, blood flow, and fixation of CO 2 into compounds other than dissolved gas and bicarbonate ions. For each of ten dogs, brain pH was measured with PET at two values of PaCO 2 (range 21-67 mm Hg). The kinetic model fit the data well during both inhalation and washout of the label, with residual root mean square (RMS) deviations of the model from the measurements consistent with the statistical quality of the PET data. Brain pH calculated from the PET data shows a linear variation with log(PaCO 2 ). These results were in good agreement with previously reported measurements of brain pH, both in absolute value and in variation with PCO 2 . The interpretation of these pH values in normal and pathological states is discussed

  2. How the risky features of previous selection affect subsequent decision-making: evidence from behavioral and fMRI measures.

    Science.gov (United States)

    Dong, Guangheng; Zhang, Yifen; Xu, Jiaojing; Lin, Xiao; Du, Xiaoxia

    2015-01-01

    Human decision making is rarely conducted in temporal isolation. It is often biased and affected by environmental variables, particularly prior selections. In this study, we used a task that simulates a real gambling process to explore the effect of the risky features of a previous selection on subsequent decision making. Compared with decision making after an advantageous risk-taking situation (Risk_Adv), that after a disadvantageous risk-taking situation (Risk_Disadv) is associated with a longer response time (RT, the time spent in making decisions) and higher brain activations in the caudate and the dorsolateral prefrontal cortex (DLPFC). Compared with decisions after Risk_Adv, those after Risk_Disadv in loss trials are associated with higher brain activations in the left superior temporal gyrus (STG) and the precuneus. Brain activity and relevant RTs significantly correlated. Overall, people who experience disadvantageous risk-taking selections tend to focus on current decision making and engage cognitive endeavors in value evaluation and in the regulation of their risk-taking behaviors during decision making.

  3. A measurement evaluation program to support nuclear material control and accountability measurements in Brazilian laboratories

    International Nuclear Information System (INIS)

    Dias, Fabio C.; Mason, Peter

    2013-01-01

    A measurement evaluation program (MEP) is one of a number of valuable tools that analytical chemists can use to ensure that the data produced in the laboratory are fit for their intended purpose and consistent with expected performance values at a given time. As such, participation in a MEP is an important indicator of the quality of analytical data, and is recognized as such by independent regulatory and/or accreditation bodies. With the intent to implement such a program in Brazil, in November 2012 the Nuclear Energy Commission of Brazil (CNEN), with support from the Department of Energy of the United States' (US-DOE International Safeguards and Engagement Program), decided to initiate a technical cooperation project aiming at organizing a Safeguards Measurement Evaluation Program (SMEP) for Brazilian facilities. The project, entitled Action Sheet 23, was formalized under the terms of the Agreement between the US-DOE and the CNEN concerning research and development in nuclear material control, accountancy, verification, physical protection, and advanced containment and surveillance technologies for International Safeguards Applications. The work, jointly performed by the CNEN's Safeguards Laboratory (LASAL) and the New Brunswick Laboratory (NBL), has the objective to strengthen the traceability of accountability measurements and ensure adequate quality of safeguards measurements for facilities within Brazil, utilizing test samples characterized and provided by NBL. Recommendations to participants included measurement frequency, number of results per sample and format for reporting results using ISO methods for calculating and expressing measurement uncertainties. In this paper, we discuss the main steps taken by CNEN and NBL aiming at implementing such a program and the expected results, in particular the impact of uncertainty estimation on the evaluation of performance of each participant laboratory. The program is considered by Brazilian safeguards authorities

  4. A measurement evaluation program to support nuclear material control and accountability measurements in Brazilian laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Fabio C., E-mail: fabio@ird.gov.br [Comissao Nacional de Energia Nuclear (CNEN-RJ), Rio de Janeiro, RJ (Brazil); Mason, Peter, E-mail: peter.mason@ch.doe.gov [New Brunswick Laboratory (DOE/NBL), Argonne, IL (United States)

    2013-07-01

    A measurement evaluation program (MEP) is one of a number of valuable tools that analytical chemists can use to ensure that the data produced in the laboratory are fit for their intended purpose and consistent with expected performance values at a given time. As such, participation in a MEP is an important indicator of the quality of analytical data, and is recognized as such by independent regulatory and/or accreditation bodies. With the intent to implement such a program in Brazil, in November 2012 the Nuclear Energy Commission of Brazil (CNEN), with support from the Department of Energy of the United States' (US-DOE International Safeguards and Engagement Program), decided to initiate a technical cooperation project aiming at organizing a Safeguards Measurement Evaluation Program (SMEP) for Brazilian facilities. The project, entitled Action Sheet 23, was formalized under the terms of the Agreement between the US-DOE and the CNEN concerning research and development in nuclear material control, accountancy, verification, physical protection, and advanced containment and surveillance technologies for International Safeguards Applications. The work, jointly performed by the CNEN's Safeguards Laboratory (LASAL) and the New Brunswick Laboratory (NBL), has the objective to strengthen the traceability of accountability measurements and ensure adequate quality of safeguards measurements for facilities within Brazil, utilizing test samples characterized and provided by NBL. Recommendations to participants included measurement frequency, number of results per sample and format for reporting results using ISO methods for calculating and expressing measurement uncertainties. In this paper, we discuss the main steps taken by CNEN and NBL aiming at implementing such a program and the expected results, in particular the impact of uncertainty estimation on the evaluation of performance of each participant laboratory. The program is considered by Brazilian safeguards

  5. Affective Evaluations of Exercising: The Role of Automatic-Reflective Evaluation Discrepancy.

    Science.gov (United States)

    Brand, Ralf; Antoniewicz, Franziska

    2016-12-01

    Sometimes our automatic evaluations do not correspond well with those we can reflect on and articulate. We present a novel approach to the assessment of automatic and reflective affective evaluations of exercising. Based on the assumptions of the associative-propositional processes in evaluation model, we measured participants' automatic evaluations of exercise and then shared this information with them, asked them to reflect on it and rate eventual discrepancy between their reflective evaluation and the assessment of their automatic evaluation. We found that mismatch between self-reported ideal exercise frequency and actual exercise frequency over the previous 14 weeks could be regressed on the discrepancy between a relatively negative automatic and a more positive reflective evaluation. This study illustrates the potential of a dual-process approach to the measurement of evaluative responses and suggests that mistrusting one's negative spontaneous reaction to exercise and asserting a very positive reflective evaluation instead leads to the adoption of inflated exercise goals.

  6. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  7. Working with Error and Uncertainty to Increase Measurement Validity

    Science.gov (United States)

    Amrein-Beardsley, Audrey; Barnett, Joshua H.

    2012-01-01

    Over the previous two decades, the era of accountability has amplified efforts to measure educational effectiveness more than Edward Thorndike, the father of educational measurement, likely would have imagined. Expressly, the measurement structure for evaluating educational effectiveness continues to rely increasingly on one sole…

  8. Development and evaluation of measurement devices used to support testing of radioactive material transportation packages

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Ammerman, D.J.; Stenberg, D.R.; Bronowski, D.R.; Arviso, M.

    1992-01-01

    Radioactive material package designers use structural testing to verify and demonstrate package performance. A major part of evaluating structural response is the collection of instrumentation measurement data. Sandia National Laboratories (SNL) has an ongoing program to develop and evaluate measurement devices to support testing of radioactive material packages. Measurement devices developed in support of this activity include evaluation channels, ruggedly constructed linear variable differential transformers, and piezoresistive accelerometers with enhanced measurement capabilities. In addition to developing measurement devices, a method has been derived to evaluate accelerometers and strain gages for measurement repeatability, ruggedness, and manufacturers' calibration data under both laboratory and field conditions. The developed measurement devices and evaluation technique will be discussed and the results of the evaluation will be presented

  9. Evaluation of conventional and high-performance routine solar radiation measurements for improved solar resource, climatological trends, and radiative modeling

    Energy Technology Data Exchange (ETDEWEB)

    Gueymard, Christian A. [Solar Consulting Services, P.O. Box 392, Colebrook, NH 03576 (United States); Myers, Daryl R. [National Renewable Energy Laboratory, 1617 Cole Blvd., Golden, CO 80401-3305 (United States)

    2009-02-15

    The solar renewable energy community depends on radiometric measurements and instrumentation for data to design and monitor solar energy systems, and develop and validate solar radiation models. This contribution evaluates the impact of instrument uncertainties contributing to data inaccuracies and their effect on short-term and long-term measurement series, and on radiation model validation studies. For the latter part, transposition (horizontal-to-tilt) models are used as an example. Confirming previous studies, it is found that a widely used pyranometer strongly underestimates diffuse and global radiation, particularly in winter, unless appropriate corrective measures are taken. Other types of measurement problems are also discussed, such as those involved in the indirect determination of direct or diffuse irradiance, and in shadowband correction methods. The sensitivity of the predictions from transposition models to inaccuracies in input radiation data is demonstrated. Caution is therefore issued to the whole community regarding drawing detailed conclusions about solar radiation data without due attention to the data quality issues only recently identified. (author)

  10. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    CERN Document Server

    Nakamura, T; Tonoike, K

    2003-01-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose b...

  11. A Fuzzy-Based Fusion Method of Multimodal Sensor-Based Measurements for the Quantitative Evaluation of Eye Fatigue on 3D Displays

    Directory of Open Access Journals (Sweden)

    Jae Won Bang

    2015-05-01

    Full Text Available With the rapid increase of 3-dimensional (3D content, considerable research related to the 3D human factor has been undertaken for quantitatively evaluating visual discomfort, including eye fatigue and dizziness, caused by viewing 3D content. Various modalities such as electroencephalograms (EEGs, biomedical signals, and eye responses have been investigated. However, the majority of the previous research has analyzed each modality separately to measure user eye fatigue. This cannot guarantee the credibility of the resulting eye fatigue evaluations. Therefore, we propose a new method for quantitatively evaluating eye fatigue related to 3D content by combining multimodal measurements. This research is novel for the following four reasons: first, for the evaluation of eye fatigue with high credibility on 3D displays, a fuzzy-based fusion method (FBFM is proposed based on the multimodalities of EEG signals, eye blinking rate (BR, facial temperature (FT, and subjective evaluation (SE; second, to measure a more accurate variation of eye fatigue (before and after watching a 3D display, we obtain the quality scores of EEG signals, eye BR, FT and SE; third, for combining the values of the four modalities we obtain the optimal weights of the EEG signals BR, FT and SE using a fuzzy system based on quality scores; fourth, the quantitative level of the variation of eye fatigue is finally obtained using the weighted sum of the values measured by the four modalities. Experimental results confirm that the effectiveness of the proposed FBFM is greater than other conventional multimodal measurements. Moreover, the credibility of the variations of the eye fatigue using the FBFM before and after watching the 3D display is proven using a t-test and descriptive statistical analysis using effect size.

  12. Front-End Electronics for Verification Measurements: Performance Evaluation and Viability of Advanced Tamper Indicating Measures

    International Nuclear Information System (INIS)

    Smith, E.; Conrad, R.; Morris, S.; Ramuhalli, P.; Sheen, D.; Schanfein, M.; Ianakiev, K.; Browne, M.; Svoboda, J.

    2015-01-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended, remotely monitored measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. A collaboration between Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL) is working to advance the IAEA's capabilities in these areas. The first objective of the project is to perform a comprehensive evaluation of a prototype front-end electronics package, as specified by the IAEA and procured from a commercial vendor. This evaluation begins with an assessment against the IAEA's original technical specifications and expands to consider the strengths and limitations over a broad range of important parameters that include: sensor types, cable types, and the spectrum of industrial electromagnetic noise that can degrade signals from remotely located detectors. A second objective of the collaboration is to explore advanced tamper-indicating (TI) measures that could help to address some of the long-standing data authentication challenges with IAEA's unattended systems. The collaboration has defined high-priority tampering scenarios to consider (e.g., replacement of sensor, intrusion into cable), and drafted preliminary requirements for advanced TI measures. The collaborators are performing independent TI investigations of different candidate approaches: active time-domain reflectometry (PNNL), passive noise analysis (INL), and pulse-by-pulse analysis and correction (LANL). The initial investigations focus on scenarios where new TI measures are retrofitted into existing IAEA UMS deployments; subsequent work will consider the integration of advanced TI methods into new IAEA UMS deployments where the detector is separated from the front-end electronics. In this paper, project progress

  13. Measuring Evaluation Fears in Adolescence: Psychometric Validation of the Portuguese Versions of the Fear of Positive Evaluation Scale and the Specific Fear of Negative Evaluation Scale

    Science.gov (United States)

    Vagos, Paula; Salvador, Maria do Céu; Rijo, Daniel; Santos, Isabel M.; Weeks, Justin W.; Heimberg, Richard G.

    2016-01-01

    Modified measures of Fear of Negative Evaluation and Fear of Positive Evaluation were examined among Portuguese adolescents. These measures demonstrated replicable factor structure, internal consistency, and positive relationships with social anxiety and avoidance. Gender differences were found. Implications for evaluation and intervention are…

  14. A systematic review evaluating the psychometric properties of measures of social inclusion.

    Science.gov (United States)

    Cordier, Reinie; Milbourn, Ben; Martin, Robyn; Buchanan, Angus; Chung, Donna; Speyer, Renée

    2017-01-01

    Improving social inclusion opportunities for population health has been identified as a priority area for international policy. There is a need to comprehensively examine and evaluate the quality of psychometric properties of measures of social inclusion that are used to guide social policy and outcomes. To conduct a systematic review of the literature on all current measures of social inclusion for any population group, to evaluate the quality of the psychometric properties of identified measures, and to evaluate if they capture the construct of social inclusion. A systematic search was performed using five electronic databases: CINAHL, PsycINFO, Embase, ERIC and Pubmed and grey literature were sourced to identify measures of social inclusion. The psychometric properties of the social inclusion measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria. Of the 109 measures identified, twenty-five measures, involving twenty-five studies and one manual met the inclusion criteria. The overall quality of the reviewed measures was variable, with the Social and Community Opportunities Profile-Short, Social Connectedness Scale and the Social Inclusion Scale demonstrating the strongest evidence for sound psychometric quality. The most common domain included in the measures was connectedness (21), followed by participation (19); the domain of citizenship was covered by the least number of measures (10). No single instrument measured all aspects within the three domains of social inclusion. Of the measures with sound psychometric evidence, the Social and Community Opportunities Profile-Short captured the construct of social inclusion best. The overall quality of the psychometric properties demonstrate that the current suite of available instruments for the measurement of social inclusion are promising but need further refinement. There is a need for a universal working definition of social inclusion as an overarching

  15. Field evaluation of a novel haemoglobin measuring device ...

    African Journals Online (AJOL)

    Objective. To evaluate the use of a robust, cheap method for haemoglobin estimation by non-laboratory-trained personnel in a rural setting. Design. Comparative study. Setting. Tintswalo Hospital. Acomhoek. Participants. 7 nursing sisters, 4 medical students, 2 lay persons. Outcome measures. Haemoglobin estimates ...

  16. Measured and evaluated neutron cross sections of elemental bismuth

    International Nuclear Information System (INIS)

    Smith, A.; Guenther, P.; Smith, D.; Whalen, J.; Howerton, R.

    1980-04-01

    Neutron total cross sections of elemental bismuth are measured with broad resolution from 1.2 to 4.5 MeV to accuracies of approx. = 1%. Neutron-differential-elastic-scattering cross sections of bismuth are measured from 1.5 to 4.0 MeV at incident neutron energy intervals of approx.< 0.2 MeV over the scattered-neutron angular range approx. = 20 to 160 deg. Differential neutron cross sections for the excitation of observed states in bismuth at 895 +- 12, 1606 +- 14, 2590 +- 15, 2762 +- 29, 3022 +- 21, and 3144 +- 15 keV are determined at incident neutron energies up to 4.0 MeV. An optical-statistical model is deduced from the measured values. This model, the present experimental results, and information available elsewhere in the literature are used to construct a comprehensive evaluated nuclear data file for elemental bismuth in the ENDF format. The evaluated file is particularly suited to the neutronic needs of the fusion-fission hybrid designer. 87 references, 10 figures, 6 tables

  17. A previous hamstring injury affects kicking mechanics in soccer players.

    Science.gov (United States)

    Navandar, Archit; Veiga, Santiago; Torres, Gonzalo; Chorro, David; Navarro, Enrique

    2018-01-10

    Although the kicking skill is influenced by limb dominance and sex, how a previous hamstring injury affects kicking has not been studied in detail. Thus, the objective of this study was to evaluate the effect of sex and limb dominance on kicking in limbs with and without a previous hamstring injury. 45 professional players (males: n=19, previously injured players=4, age=21.16 ± 2.00 years; females: n=19, previously injured players=10, age=22.15 ± 4.50 years) performed 5 kicks each with their preferred and non-preferred limb at a target 7m away, which were recorded with a three-dimensional motion capture system. Kinematic and kinetic variables were extracted for the backswing, leg cocking, leg acceleration and follow through phases. A shorter backswing (20.20 ± 3.49% vs 25.64 ± 4.57%), and differences in knee flexion angle (58 ± 10o vs 72 ± 14o) and hip flexion velocity (8 ± 0rad/s vs 10 ± 2rad/s) were observed in previously injured, non-preferred limb kicks for females. A lower peak hip linear velocity (3.50 ± 0.84m/s vs 4.10 ± 0.45m/s) was observed in previously injured, preferred limb kicks of females. These differences occurred in the backswing and leg-cocking phases where the hamstring muscles were the most active. A variation in the functioning of the hamstring muscles and that of the gluteus maximus and iliopsoas in the case of a previous injury could account for the differences observed in the kicking pattern. Therefore, the effects of a previous hamstring injury must be considered while designing rehabilitation programs to re-educate kicking movement.

  18. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  19. Ultrasound transmission measurements for tensile strength evaluation of tablets.

    Science.gov (United States)

    Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko

    2011-05-16

    Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Evaluating the use of gas discharge visualization to measure massage therapy outcomes

    Science.gov (United States)

    Haun, Jolie; Patel, Nitin; Schwartz, Gary; Ritenbaugh, Cheryl

    2017-01-01

    Background The purpose of this study was to evaluate the short-term effects of massage therapy using gas discharge visualization (GDV), a computerized biophysical electrophoton capture (EPC), in tandem with traditional self-report measures to evaluate the use of GDV measurement to assess the bioenergetic whole-person effects of massage therapy. Methods This study used a single treatment group, pre–post-repeated measures design with a sample of 23 healthy adults. This study utilized a single 50-min full-body relaxation massage with participants. GDV measurement method, an EPC, and traditional paper-based measures evaluating pain, stress, muscle tension, and well-being were used to assess intervention outcomes. Results Significant differences were found between pre- and post-measures of well-being, pain, stress, muscle tension, and GDV parameters. Pearson correlations indicate the GDV measure is correlated with pain and stress, variables that impact the whole person. Conclusions This study demonstrates that GDV parameters may be used to indicate significant bioenergetic change from pre- to post-massage. Findings warrant further investigation with a larger diverse sample size and control group to further explore GDV as a measure of whole-person bioenergetic effects associated with massage. PMID:26087069

  1. An experimental evaluation of a new designed apparatus (NDA) for the rapid measurement of impaired motor function in rats.

    Science.gov (United States)

    Jarrahi, M; Sedighi Moghadam, B; Torkmandi, H

    2015-08-15

    Assessment of the ability of rat to balance by rotarod apparatus (ROTA) is frequently used as a measure of impaired motor system function. Most of these methods have some disadvantages, such as failing to sense motor coordination rather than endurance and as the sensitivity of the method is low, more animals are needed to obtain statistically significant results. We have designed and tested a new designed apparatus (NDA) to measure motor system function in rats. Our system consists of a glass box containing 4 beams which placed with 1cm distance between them, two electrical motors for rotating the beams, and a camera to record the movements of the rats. The RPM of the beams is adjustable digitally between 0 and 50 rounds per minute. We evaluated experimentally the capability of the NDA for the rapid measurement of impaired motor function in rats. Also we demonstrated that the sensitivity of the NDA increases by faster rotation speeds and may be more sensitive than ROTA for evaluating of impaired motor system function. Compared to a previous version of this task, our NDA provides a more efficient method to test rodents for studies of motor system function after impaired motor nervous system. In summary, our NDA will allow high efficient monitoring of rat motor system function and may be more sensitive than ROTA for evaluating of impaired motor system function in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. The Efficacy of Stuttering Measurement Training: Evaluating Two Training Programs

    Science.gov (United States)

    Bainbridge, Lauren A.; Stavros, Candace; Ebrahimian, Mineh; Wang, Yuedong; Ingham, Roger J.

    2015-01-01

    Purpose: Two stuttering measurement training programs currently used for training clinicians were evaluated for their efficacy in improving the accuracy of total stuttering event counting. Method: Four groups, each with 12 randomly allocated participants, completed a pretest-posttest design training study. They were evaluated by their counts of…

  3. An evaluation of professional quality measurement systems for the ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... An evaluation of professional quality measurement systems for the automotive industry ... The ultimate goal of this study is to get comparable quantitative information about ...

  4. Multivariate Methods Based Soft Measurement for Wine Quality Evaluation

    Directory of Open Access Journals (Sweden)

    Shen Yin

    2014-01-01

    a decision. However, since the physicochemical indexes of wine can to some extent reflect the quality of wine, the multivariate statistical methods based soft measure can help the oenologist in wine evaluation.

  5. Understanding and Measuring Evaluation Capacity: A Model and Instrument Validation Study

    Science.gov (United States)

    Taylor-Ritzler, Tina; Suarez-Balcazar, Yolanda; Garcia-Iriarte, Edurne; Henry, David B.; Balcazar, Fabricio E.

    2013-01-01

    This study describes the development and validation of the Evaluation Capacity Assessment Instrument (ECAI), a measure designed to assess evaluation capacity among staff of nonprofit organizations that is based on a synthesis model of evaluation capacity. One hundred and sixty-nine staff of nonprofit organizations completed the ECAI. The 68-item…

  6. Association between previous splenectomy and gastric dilatation-volvulus in dogs: 453 cases (2004-2009).

    Science.gov (United States)

    Sartor, Angela J; Bentley, Adrienne M; Brown, Dorothy C

    2013-05-15

    To evaluate the association between previous splenectomy and gastric dilatation-volvulus (GDV) in dogs. Multi-institutional retrospective case-control study. Animals-151 dogs treated surgically for GDV and 302 control dogs with no history of GDV. Computerized records of dogs evaluated via exploratory laparotomy or abdominal ultrasonography were searched, and dogs with GDV and dogs without GDV (control dogs) were identified. Two control dogs were matched with respect to age, body weight, sex, neuter status, and breed to each dog with GDV. Data were collected on the presence or absence of the spleen for both dogs with GDV and control dogs. Conditional logistic regression analysis was used to investigate the association of previous splenectomy with GDV. 6 (4%) dogs in the GDV group and 3 (1%) dogs in the control group had a history of previous splenectomy. The odds of GDV in dogs with a history of previous splenectomy in this population of dogs were 5.3 times those of dogs without a history of previous splenectomy (95% confidence interval, 1.1 to 26.8). For the patients in the present study, there was an increased odds of GDV in dogs with a history of splenectomy. Prophylactic gastropexy may be considered in dogs undergoing a splenectomy, particularly if other risk factors for GDV are present.

  7. Measuring the effects of image interpretation: An evaluative framework

    International Nuclear Information System (INIS)

    Brealey, Stephen

    2001-01-01

    The relaxing of restrictions on reporting films has resulted in radiographers and other health care professionals becoming increasingly involved in the interpretation of images in areas such as mammography, ultrasound and plain film radiography. However, errors and variation in the interpretation of images now represents the weakest area of clinical imaging. This has been highlighted by the difficulty of establishing standards to measure the film reading performance of radiographers as part of role extension initiatives. Despite a growing literature of studies that evaluate the film reading performance of different health care professionals, there is a paucity of evidence of the subsequent effects on the referring clinician's diagnosis, management plans and patient outcome. This paper proposes an evaluative framework that can be used to measure the chain of events from the initial technical assessment of observers' potential to interpret images using search behaviour techniques, through to the potential costs and benefits to society. Evaluating the wider implications of alternative or complementary reporting policies is essential for generating the evidence base to comprehensively underpin policy and practice and direct future research. Brealey, S. (2001)

  8. Evaluating an interactive voice response system for persons with disabilities

    CSIR Research Space (South Africa)

    Greeff, M

    2008-11-01

    Full Text Available -evaluated before the next iteration. During the re-evaluation its current fitness value is compared with its previous fitness value, i.e. its fitness value after the previous iteration. If the two values differ more than a specified value, 2922 978... when the true POF is unknown. The size of the non-dominated solution set can also be used to measure an algorithm’s performance [18]. Ca´mara et al. proposed measures of accuracy, stability and reaction capacity of an algorithm, that are based...

  9. A systematic review evaluating the psychometric properties of measures of social inclusion

    Science.gov (United States)

    Milbourn, Ben; Martin, Robyn; Buchanan, Angus; Chung, Donna; Speyer, Renée

    2017-01-01

    Introduction Improving social inclusion opportunities for population health has been identified as a priority area for international policy. There is a need to comprehensively examine and evaluate the quality of psychometric properties of measures of social inclusion that are used to guide social policy and outcomes. Objective To conduct a systematic review of the literature on all current measures of social inclusion for any population group, to evaluate the quality of the psychometric properties of identified measures, and to evaluate if they capture the construct of social inclusion. Methods A systematic search was performed using five electronic databases: CINAHL, PsycINFO, Embase, ERIC and Pubmed and grey literature were sourced to identify measures of social inclusion. The psychometric properties of the social inclusion measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria. Results Of the 109 measures identified, twenty-five measures, involving twenty-five studies and one manual met the inclusion criteria. The overall quality of the reviewed measures was variable, with the Social and Community Opportunities Profile-Short, Social Connectedness Scale and the Social Inclusion Scale demonstrating the strongest evidence for sound psychometric quality. The most common domain included in the measures was connectedness (21), followed by participation (19); the domain of citizenship was covered by the least number of measures (10). No single instrument measured all aspects within the three domains of social inclusion. Of the measures with sound psychometric evidence, the Social and Community Opportunities Profile-Short captured the construct of social inclusion best. Conclusions The overall quality of the psychometric properties demonstrate that the current suite of available instruments for the measurement of social inclusion are promising but need further refinement. There is a need for a universal working

  10. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Science.gov (United States)

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  11. Toward autonomous measurements of photosynthetic electron transport rates: An evaluation of active fluorescence-based measurements of photochemistry

    NARCIS (Netherlands)

    Silsbe, G.M.; Oxborough, K.; Suggett, D.J.; Forster, R.M.; Ihnken, S.; Komárek, O.; Lawrenz, E.; Prášil, O.; Röttgers, R.; Šicner, M.; Simis, S.G.H.; Van Dijk, M.A.; Kromkamp, J.C.

    2015-01-01

    This study presents a methods evaluation and intercalibration of active fluorescence-based measurements of the quantum yield ( inline image) and absorption coefficient ( inline image) of photosystem II (PSII) photochemistry. Measurements of inline image, inline image, and irradiance (E) can be

  12. Evaluation of the measurement uncertainty when measuring the resistance of solid isolating materials to tracking

    Science.gov (United States)

    Stare, E.; Beges, G.; Drnovsek, J.

    2006-07-01

    This paper presents the results of research into the measurement of the resistance of solid isolating materials to tracking. Two types of tracking were investigated: the proof tracking index (PTI) and the comparative tracking index (CTI). Evaluation of the measurement uncertainty in a case study was performed using a test method in accordance with the IEC 60112 standard. In the scope of the tests performed here, this particular test method was used to ensure the safety of electrical appliances. According to the EN ISO/IEC 17025 standard (EN ISO/IEC 17025), in the process of conformity assessment, the evaluation of the measurement uncertainty of the test method should be carried out. In the present article, possible influential parameters that are in accordance with the third and fourth editions of the standard IEC 60112 are discussed. The differences, ambiguities or lack of guidance referring to both editions of the standard are described in the article 'Ambiguities in technical standards—case study IEC 60112—measuring the resistance of solid isolating materials to tracking' (submitted for publication). Several hundred measurements were taken in the present experiments in order to form the basis for the results and conclusions presented. A specific problem of the test (according to the IEC 60112 standard) is the great variety of influential physical parameters (mechanical, electrical, chemical, etc) that can affect the results. At the end of the present article therefore, there is a histogram containing information on the contributions to the measurement uncertainty.

  13. Response to deep TMS in depressive patients with previous electroconvulsive treatment.

    Science.gov (United States)

    Rosenberg, Oded; Zangen, Abraham; Stryjer, Rafael; Kotler, Moshe; Dannon, Pinhas N

    2010-10-01

    The efficacy of transcranial magnetic stimulation (TMS) in the treatment of major depression has already been shown. Novel TMS coils allowing stimulation of deeper brain regions have recently been developed and studied. Our study is aimed at exploring the possible efficacy of deep TMS in patients with resistant depression, who previously underwent electroconvalsive therapy (ECT). Using Brainsway's deep TMS H1 coil, six patients who previously underwent ECT, were treated with 120% power of the motor threshold at a frequency of 20 Hz. Patients underwent five sessions per week, up to 4 weeks. Before the study, patients were evaluated using the Hamilton depression rating scale (HDRS, 24 items), the Hamilton anxiety scale, and the Beck depression inventory and were again evaluated after 5, 10, 15, and 20 daily treatments. Response to treatment was considered a reduction in the HDRS of at least 50%, and remission was considered a reduction of the HDRS-24 below 10 points. Two of six patients responded to the treatment with deep TMS, including one who achieved full remission. Our results suggest the possibility of a subpopulation of depressed patients who may benefit from deep TMS treatment, including patients who did not respond to ECT previously. However, the power of the study is small and similar larger samples are needed. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. An evaluation of centrality measures used in cluster analysis

    Science.gov (United States)

    Engström, Christopher; Silvestrov, Sergei

    2014-12-01

    Clustering of data into groups of similar objects plays an important part when analysing many types of data, especially when the datasets are large as they often are in for example bioinformatics, social networks and computational linguistics. Many clustering algorithms such as K-means and some types of hierarchical clustering need a number of centroids representing the 'center' of the clusters. The choice of centroids for the initial clusters often plays an important role in the quality of the clusters. Since a data point with a high centrality supposedly lies close to the 'center' of some cluster, this can be used to assign centroids rather than through some other method such as picking them at random. Some work have been done to evaluate the use of centrality measures such as degree, betweenness and eigenvector centrality in clustering algorithms. The aim of this article is to compare and evaluate the usefulness of a number of common centrality measures such as the above mentioned and others such as PageRank and related measures.

  15. Young Children's Understandings of Length Measurement: Evaluating a Learning Trajectory

    Science.gov (United States)

    Szilagyi, Janka; Clements, Douglas H.; Sarama, Julie

    2013-01-01

    This study investigated the development of length measurement ideas in students from prekindergarten through 2nd grade. The main purpose was to evaluate and elaborate the developmental progression, or levels of thinking, of a hypothesized learning trajectory for length measurement to ensure that the sequence of levels of thinking is consistent…

  16. Spectral irradiance measurements and hazard evaluations of sunbeds and sunlamps

    International Nuclear Information System (INIS)

    Gies, H.P.; Roy, C.R.; Elliott, G.

    1985-04-01

    The proliferation of solaria, coupled with a growing awareness of the harmful effects of exposure to ultraviolet radiation (UVR) has prompted a study on solaria and the UVR sources used in them. The detrimental effects of UV-B radiation have been known for some time but recently there has been increasing concern over the effects of UV-A radiation, which had at first been thought of as relatively harmless. Previous studies of solaria have made radiometric measurements of the UVR lamp outputs, but since the biological effectiveness of UVR is wavelength dependent, particularly in the UV-B region where it varies by several orders of magnitude, there is a need for spectroradiometric measurements. Such measurements have been made at fourteen solaria in the Melbourne metropolitan area. Laboratory measurements have also been made on individual UVR fluorescent lamps and sunlamps. Results have been compared with the requirements of Australian Standard 2635 (1983), 'Installation, maintenance and operation of solaria for cosmetic purposes'

  17. A suggestion for specification of the neutron energy scale in measurements, analyses and evaluations of differential reaction cross-section data

    International Nuclear Information System (INIS)

    Smith, D.L.

    1992-01-01

    Neutron energy distributions (spectra) in differential neutron cross section measurements are represented conventionally by giving the energies (not well defined) and full widths at half maximum of the spectra. In most modern experiments, it is possible for investigators to provide a much more thorough representation of neutron spectra. However, reporting such information would entail more numerical detail than appears practical to document. Therefore, it is suggested that such spectra be represented in publications and files of experimental data by providing the following four moments of each distribution: mean value (energy), standard deviation (resolution), skewness (asymmetry), and kurtosis (sharpness). Implementation of such a standard for data reporting would offer evaluators a much more complete and rational basis for comparing reported values and performing evaluations than previously possible. Some examples are provided to illustrate the concepts

  18. Integral Criteria for Measuring the Quality of Teacher Evaluation

    Directory of Open Access Journals (Sweden)

    Olga Navickienė

    2012-07-01

    Full Text Available Purpose—To construct the knowledge evaluation quality integral criteria, which allows to ascertain whether the different teachers properly assess the students’ knowledge. The criteria has been tested setting up the educational experiment and examining the six mathematics lecturers’ assessments.Design/methodology/approach—This research involved the Mykolas Romeris University students of Public Administration degree second year and Management of Organizations degree first year. The test questions for students were designed using the mathematical knowledge assessment information system, which allows for closed-ended mathematical test, to obtain statistical data about test takers, to perform quality analysis of the test; in the middle and the end of the semester.Findings—The construction technique for the evaluation quality criteria of the students’ working results assessment, which were performed by six different lecturers, during practical trainings, seminars, laboratory and other sessions is proposed in this article.Research limitations/implications—The constructed evaluation criteria is universal: it does not depend on the particular subject; it can be applied to several groups, courses or lecturers. It depends on three calculated indicators I, S, K, which show in two ways obtained estimates of the measured information compatibility of degrees, marks matching and correlation terms.Practical implications—The integral criteria has been tested examining the six mathematics lecturers’ assessments.Originality/Value—Constructing the criteria have been used the educational measurement models of authors of this article and other researchers, however its’ connection to general (integral criteria, best of authors’ knowledge, is original and have not be researched before.Keywords: knowledge evaluation, quality of teacher evaluation, evaluation of teachers, mathematical modeling.Research type: research paper.

  19. Measuring service life and evaluating the quality of solid tires

    Directory of Open Access Journals (Sweden)

    Charoenyut Dechwayukul

    2010-08-01

    Full Text Available The objective of this research is to propose procedures for measuring service life and evaluating the quality of locallymade and used solid tires in Thailand. The solid tires were stressed and rotated until blowout on a drum-like test apparatuswhich is designed, constructed by the authors and equipped with laboratory instrumentation. Solid tires from five differentmanufacturers were selected for testing. We measured service life, length of time to tire failure, at three different loadingamplitudes and three different speeds on the testing drum. The service life of all specimens was studied and compared todetermine the possibility of using service life to evaluate the quality of a solid tire.

  20. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  1. Research on the measurement technology and evaluation method of photobiological safety

    Science.gov (United States)

    Dai, Cai-hong; Wu, Zhi-feng; Chen, Bin-hua; Wang, Yan-fei; Li, Xiang-zhao; Fu, Lei

    2013-12-01

    Lamps and lamp system are widely used in large quantities in an era. The evaluation and control of optical radiation hazards of lamps and lamp systems is far more complicated. A special measurement and traceability facility was set up at NIM (National Institute of Metrology, China) to evaluate the optical radiation safety of lamp and lamp system, which includes a double grating spectroradiometer OL750D with two different entrance systems of spectral radiance and spectral irradiance traceable to the national primary standard of spectral irradiance by a 1000W spectral irradiance standard lamp, 40W deuterium lamp and a standard diffuser plate. The technical requirements of the measurement instrumentation used for optical radiation safety evaluation including monochromator type, wavelength accuracy, input optics, spectral scan interval and calibration sources are recommended also in this paper. Spectral radiance of a series of LED electric torches and infrared sources were measured by using the new developed system, and potential radiation hazards of retinal blue light hazard and retinal thermal hazard are calculated and evaluated. The optical radiation hazards of some samples are listed in Risk Group 2 (Moderate-Risk).

  2. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    Science.gov (United States)

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  3. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  4. Measuring Dynamic and Kinetic Information in the Previously Inaccessible Supra-tc Window of Nanoseconds to Microseconds by Solution NMR Spectroscopy

    Directory of Open Access Journals (Sweden)

    Donghan Lee

    2013-09-01

    Full Text Available Nuclear Magnetic Resonance (NMR spectroscopy is a powerful tool that has enabled experimentalists to characterize molecular dynamics and kinetics spanning a wide range of time-scales from picoseconds to days. This review focuses on addressing the previously inaccessible supra-τc window (defined as τc < supra-τc < 40 μs; in which τc is the overall tumbling time of a molecule from the perspective of local inter-nuclear vector dynamics extracted from residual dipolar couplings (RDCs and from the perspective of conformational exchange captured by relaxation dispersion measurements (RD. The goal of the first section is to present a detailed analysis of how to extract protein dynamics encoded in RDCs and how to relate this information to protein functionality within the previously inaccessible supra-τc window. In the second section, the current state of the art for RD is analyzed, as well as the considerable progress toward pushing the sensitivity of RD further into the supra-τc scale by up to a factor of two (motion up to 25 ms. From the data obtained with these techniques and methodology, the importance of the supra-τ c scale for protein function and molecular recognition is becoming increasingly clearer as the connection between motion on the supra-τc scale and protein functionality from the experimental side is further strengthened with results from molecular dynamics simulations.

  5. Feature binding and attention in working memory: a resolution of previous contradictory findings.

    Science.gov (United States)

    Allen, Richard J; Hitch, Graham J; Mate, Judit; Baddeley, Alan D

    2012-01-01

    We aimed to resolve an apparent contradiction between previous experiments from different laboratories, using dual-task methodology to compare effects of a concurrent executive load on immediate recognition memory for colours or shapes of items or their colour-shape combinations. Results of two experiments confirmed previous evidence that an irrelevant attentional load interferes equally with memory for features and memory for feature bindings. Detailed analyses suggested that previous contradictory evidence arose from limitations in the way recognition memory was measured. The present findings are inconsistent with an earlier suggestion that feature binding takes place within a multimodal episodic buffer Baddeley, ( 2000 ) and support a subsequent account in which binding takes place automatically prior to information entering the episodic buffer Baddeley, Allen, & Hitch, ( 2011 ). Methodologically, the results suggest that different measures of recognition memory performance (A', d', corrected recognition) give a converging picture of main effects, but are less consistent in detecting interactions. We suggest that this limitation on the reliability of measuring recognition should be taken into account in future research so as to avoid problems of replication that turn out to be more apparent than real.

  6. Radon measurements of groundwater in Mexico

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Cortes, A.

    1991-01-01

    Radon measurement has important applications in hydrogeological studies. Specifically, radon measurement is used to determine the fluctuations of the piezometric levels in groundwater and, in some cases, the path of the water, which is one of the key parameters for evaluating hydrogeological resources. Water from springs and deep wells in the Basin of Mexico and the valley of San Luis Potosi were sampled, measured and analyzed by previous authors. In this work, a method for measuring 222 Rn in groundwater by using a passive detector is presented and the results are compared with a similar experiment performed at the same time, using a dynamic method. The aim of the work is to develop a method for detecting, evaluating and measuring the 222 Rn in groundwater by using SSNTD technology. (author)

  7. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  8. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  9. Status of beta measurement evaluation and upgrade program

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1986-01-01

    In 1983, the US Department of Energy (DOE) initiated a program to evaluate and upgrade beta dosimetry capabilities at DOE and DOE-contractor facilities. The program has several elements which structure the development of improvements in beta measurement practices. In addition to Pacific Northwest Laboratory (PNL), universities, private corporations, and other DOE facilities are involved in the research efforts

  10. Evaluation of MIA, Vamil and Green Investments. Investments 2000-2004. Evaluation of tax measures and effects

    International Nuclear Information System (INIS)

    2007-07-01

    The Environmental Investment Allowance (MIA), the Random Depreciation of Environmental Investments (VAMIL) and green investments entail fiscal costs that need ex-post evaluation based on the regulations of the RPE (ministerial regulation on performance measurement and evaluation). The aim of the evaluation was to describe the effectiveness of the policy instruments and their implementation. In addition to this basic objective a secondary objective was to provide insight in the expenditure of the means and to list improvement options. [mk] [nl

  11. A new concept of feature-based gauge for coordinate measuring arm evaluation

    Science.gov (United States)

    Cuesta, E.; González-Madruga, D.; Alvarez, B. J.; Barreiro, J.

    2014-06-01

    Articulated arm coordinate measuring machines (AACMM or CMA) have conquered a market share in the actual dimensional metrology field, overall when their role implies the inspection of geometrical and dimensional tolerances in an accurate 3D environment for medium-size parts. However, the unavoidable fact of AACMM manual operation constrains its reliability to a great extent, avoiding rigorous evaluation and casting doubt upon the usefulness of external calibration. In this research, a dimensional gauge especially aimed at AACMM evaluation has been developed. Furthermore, the operator skill will be revealed through the use of this gauge. A set of geometrical features, some of them oriented to evaluate the operator and others the equipment, have been collected for the gauge. The proposed evaluation methodology clearly distinguishes between dimensional and geometrical tolerances (with or without datum references), whereas actual verification standards only consider the former. Next, quality indicators deduced from the measurement results are proposed in order to compare AACMM versus coordinate measuring machine (CMM) performance, assuming that CMM possess the maximum accuracy that AACMM could reach, because CMM combines maximum contact accuracy with minimum operator influence. As a result, AACMM evaluation time could be significantly reduced since this gauge allows us to perform a customized evaluation of only those specific tolerances of interest to the user.

  12. A new concept of feature-based gauge for coordinate measuring arm evaluation

    International Nuclear Information System (INIS)

    Cuesta, E; Alvarez, B J; González-Madruga, D; Barreiro, J

    2014-01-01

    Articulated arm coordinate measuring machines (AACMM or CMA) have conquered a market share in the actual dimensional metrology field, overall when their role implies the inspection of geometrical and dimensional tolerances in an accurate 3D environment for medium-size parts. However, the unavoidable fact of AACMM manual operation constrains its reliability to a great extent, avoiding rigorous evaluation and casting doubt upon the usefulness of external calibration. In this research, a dimensional gauge especially aimed at AACMM evaluation has been developed. Furthermore, the operator skill will be revealed through the use of this gauge. A set of geometrical features, some of them oriented to evaluate the operator and others the equipment, have been collected for the gauge. The proposed evaluation methodology clearly distinguishes between dimensional and geometrical tolerances (with or without datum references), whereas actual verification standards only consider the former. Next, quality indicators deduced from the measurement results are proposed in order to compare AACMM versus coordinate measuring machine (CMM) performance, assuming that CMM possess the maximum accuracy that AACMM could reach, because CMM combines maximum contact accuracy with minimum operator influence. As a result, AACMM evaluation time could be significantly reduced since this gauge allows us to perform a customized evaluation of only those specific tolerances of interest to the user. (paper)

  13. Matched cohort study of external cephalic version in women with previous cesarean delivery.

    Science.gov (United States)

    Keepanasseril, Anish; Anand, Keerthana; Soundara Raghavan, Subrahmanian

    2017-07-01

    To evaluate the efficacy and safety of external cephalic version (ECV) among women with previous cesarean delivery. A retrospective study was conducted using data for women with previous cesarean delivery and breech presentation who underwent ECV at or after 36 weeks of pregnancy during 2011-2016. For every case, two multiparous women without previous cesarean delivery who underwent ECV and were matched for age and pregnancy duration were included. Characteristics and outcomes were compared between groups. ECV was successful for 32 (84.2%) of 38 women with previous cesarean delivery and 62 (81.6%) in the control group (P=0.728). Multivariate regression analysis confirmed that previous cesarean was not associated with ECV success (odds ratio 1.89, 95% confidence interval 0.19-18.47; P=0.244). Successful vaginal delivery after successful ECV was reported for 19 (59.4%) women in the previous cesarean delivery group and 52 (83.9%) in the control group (P<0.001). No ECV-associated complications occurred in women with previous cesarean delivery. To avoid a repeat cesarean delivery, ECV can be offered to women with breech presentation and previous cesarean delivery who are otherwise eligible for a trial of labor. © 2017 International Federation of Gynecology and Obstetrics.

  14. Pegaptanib: choroidal neovascularization in patients with age-related macular degeneration and previous arterial thromboembolic events.

    Science.gov (United States)

    Battaglia Parodi, Maurizio; Di Bartolo, Emanuele; Brue, Claudia; Cappello, Ezio; Furino, Claudio; Giuffrida, Sebastiano; Imparato, Manuela; Reibaldi, Michele

    2018-01-01

    To evaluate the efficacy and the rate of side effects of the pegylated aptamer pegaptanib in the treatment of patients with choroidal neovascularization (CNV) secondary to age-related macular degeneration (AMD) and a history of previous arterial thromboembolic events (ATEs). Twenty-three eyes of 23 patients with subfoveal CNV due to AMD and cerebrovascular accidents (n = 12) and myocardial infarction (n = 11) in the previous 6 months received intravitreal pegaptanib 0.3 mg according to a pro re nata regimen and were followed for 12 months. The paired Student t test was used to evaluate mean changes in best-corrected visual acuity (BCVA; primary outcome measure) and central foveal thickness (CFT). The mean patient age was 71.5 ± 4.6 years; there were 14 women and 9 men. The CNV was type 1, 2, and 3 in 18, 3, and 2 eyes, respectively. The mean BCVA improved from 0.67 ± 0.23 logMAR at baseline to 0.52 ± 0.31 logMAR at the end of 12-month follow-up (p = 0.044). Thirty-five percent of patients achieved ≥3 Early Treatment Diabetic Retinopathy Study lines improvement at 12 months. Mean CFT at baseline (381 ± 111 µm) decreased to 304 ± 82 µm at 12 months (p = 0.008). Patients received a mean of 4.3 ± 1.3 (range 3-7) injections. No systemic or ocular side effects occurred; no patient experienced further ATEs. Intravitreal pegaptanib can be considered a viable treatment option for patients with AMD-related CNV who are at high risk of ATEs.

  15. Multiple performance measures are needed to evaluate triage systems in the emergency department.

    Science.gov (United States)

    Zachariasse, Joany M; Nieboer, Daan; Oostenbrink, Rianne; Moll, Henriëtte A; Steyerberg, Ewout W

    2018-02-01

    Emergency department triage systems can be considered prediction rules with an ordinal outcome, where different directions of misclassification have different clinical consequences. We evaluated strategies to compare the performance of triage systems and aimed to propose a set of performance measures that should be used in future studies. We identified performance measures based on literature review and expert knowledge. Their properties are illustrated in a case study evaluating two triage modifications in a cohort of 14,485 pediatric emergency department visits. Strengths and weaknesses of the performance measures were systematically appraised. Commonly reported performance measures are measures of statistical association (34/60 studies) and diagnostic accuracy (17/60 studies). The case study illustrates that none of the performance measures fulfills all criteria for triage evaluation. Decision curves are the performance measures with the most attractive features but require dichotomization. In addition, paired diagnostic accuracy measures can be recommended for dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 for ordinal analyses. Other performance measures provide limited additional information. When comparing modifications of triage systems, decision curves and diagnostic accuracy measures should be used in a dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 in an ordinal approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Tedeschi, Enrico; Canna, Antonietta; Cocozza, Sirio; Russo, Carmela; Angelini, Valentina; Brunetti, Arturo [University ' ' Federico II' ' , Neuroradiology, Department of Advanced Biomedical Sciences, Naples (Italy); Palma, Giuseppe; Quarantelli, Mario [National Research Council, Institute of Biostructure and Bioimaging, Naples (Italy); Borrelli, Pasquale; Salvatore, Marco [IRCCS SDN, Naples (Italy); Lanzillo, Roberta; Postiglione, Emanuela; Morra, Vincenzo Brescia [University ' ' Federico II' ' , Department of Neurosciences, Reproductive and Odontostomatological Sciences, Naples (Italy)

    2016-12-15

    To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded Disability Status Scale scores:3.1±0.9), the DN R1 (1/T1) and R2* (1/T2*) relaxation rates were measured using two unenhanced 3D Dual-Echo spoiled Gradient-Echo sequences with different flip angles. Correlations of the number of previous GBCA administrations with DN R1 and R2* relaxation rates were tested, including gender and age effect, in a multivariate regression analysis. The DN R1 (normalized by brainstem) significantly correlated with the number of GBCA administrations (p<0.001), maintaining the same significance even when including MS-related factors. Instead, the DN R2* values correlated only with age (p=0.003), and not with GBCA administrations (p=0.67). In a subgroup of 35 patients for whom the administered GBCA subtype was known, the effect of GBCA on DN R1 appeared mainly related to linear GBCA. In RR-MS patients, the number of previous GBCA administrations correlates with R1 relaxation rates of DN, while R2* values remain unaffected, suggesting that T1-shortening in these patients is related to the amount of Gadolinium given. (orig.)

  17. Performance analysis and evaluation of direct phase measuring deflectometry

    Science.gov (United States)

    Zhao, Ping; Gao, Nan; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian

    2018-04-01

    Three-dimensional (3D) shape measurement of specular objects plays an important role in intelligent manufacturing applications. Phase measuring deflectometry (PMD)-based methods are widely used to obtain the 3D shapes of specular surfaces because they offer the advantages of a large dynamic range, high measurement accuracy, full-field and noncontact operation, and automatic data processing. To enable measurement of specular objects with discontinuous and/or isolated surfaces, a direct PMD (DPMD) method has been developed to build a direct relationship between phase and depth. In this paper, a new virtual measurement system is presented and is used to optimize the system parameters and evaluate the system's performance in DPMD applications. Four system parameters are analyzed to obtain accurate measurement results. Experiments are performed using simulated and actual data and the results confirm the effects of these four parameters on the measurement results. Researchers can therefore select suitable system parameters for actual DPMD (including PMD) measurement systems to obtain the 3D shapes of specular objects with high accuracy.

  18. Evaluation of a rapid dipstick (Crystal VC for the diagnosis of cholera in Zanzibar and a comparison with previous studies.

    Directory of Open Access Journals (Sweden)

    Benedikt Ley

    Full Text Available The gold standard for the diagnosis of cholera is stool culture, but this requires laboratory facilities and takes at least 24 hours. A rapid diagnostic test (RDT that can be used by minimally trained staff at treatment centers could potentially improve the reporting and management of cholera outbreaks.We evaluated the Crystal VC™ RDT under field conditions in Zanzibar in 2009. Patients presenting to treatment centers with watery diarrhea provided a stool sample for rapid diagnostic testing. Results were compared to stool culture performed in a reference laboratory. We assessed the overall performance of the RDT and evaluated whether previous intake of antibiotics, intravenous fluids, location of testing, and skill level of the technician affected the RDT results.We included stool samples from 624 patients. Compared to culture, the overall sensitivity of the RDT was 93.1% (95%CI: 88.7 to 96.2%, specificity was 49.2% (95%CI: 44.3 to 54.1%, the positive predictive value was 47.0% (95%CI: 42.1 to 52.0% and the negative predictive value was 93.6% (95%CI: 89.6 to 96.5%. The overall false positivity rate was 50.8% (213/419; fieldworkers frequently misread very faint test lines as positive.The observed sensitivity of the Crystal VC RDT evaluated was similar compared to earlier versions, while specificity was poorer. The current version of the RDT could potentially be used as a screening tool in the field. Because of the high proportion of false positive results when field workers test stool specimens, positive results will need to be confirmed with stool culture.

  19. Examples of measurement uncertainty evaluations in accordance with the revised GUM

    Science.gov (United States)

    Runje, B.; Horvatic, A.; Alar, V.; Medic, S.; Bosnjakovic, A.

    2016-11-01

    The paper presents examples of the evaluation of uncertainty components in accordance with the current and revised Guide to the expression of uncertainty in measurement (GUM). In accordance with the proposed revision of the GUM a Bayesian approach was conducted for both type A and type B evaluations.The law of propagation of uncertainty (LPU) and the law of propagation of distribution applied through the Monte Carlo method, (MCM) were used to evaluate associated standard uncertainties, expanded uncertainties and coverage intervals. Furthermore, the influence of the non-Gaussian dominant input quantity and asymmetric distribution of the output quantity y on the evaluation of measurement uncertainty was analyzed. In the case when the probabilistically coverage interval is not symmetric, the coverage interval for the probability P is estimated from the experimental probability density function using the Monte Carlo method. Key highlights of the proposed revision of the GUM were analyzed through a set of examples.

  20. Evaluation of the measurement properties of symptom measurement instruments for atopic eczema: a systematic review.

    Science.gov (United States)

    Gerbens, L A A; Prinsen, C A C; Chalmers, J R; Drucker, A M; von Kobyletzki, L B; Limpens, J; Nankervis, H; Svensson, Å; Terwee, C B; Zhang, J; Apfelbacher, C J; Spuls, P I

    2017-01-01

    Symptoms have been identified as a core outcome domain for atopic eczema (AE) trials. Various instruments exist to measure symptoms in AE, but they vary in quality and there is a lack of standardization between clinical trials. Our objective was to systematically evaluate the quality of the evidence on the measurement properties of AE symptom instruments, thereby informing consensus discussions within the Harmonising Outcome Measures for Eczema (HOME) initiative regarding the most appropriate instruments for the core outcome domain symptoms. Using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist and predefined criteria for good measurement properties on identified development and validation studies of AE symptom instruments, a best evidence synthesis was performed to draw an overall conclusion on quality of the instruments and to provide recommendations. Eighteen instruments were identified and evaluated. When the quality and results of the studies were considered, only five of these instruments had sufficient validation data to consider them for the core outcome set for the core outcome domain symptoms. These were the paediatric Itch Severity Scale (ISS), Patient-Oriented Eczema Measure (POEM), Patient-Oriented SCOring Atopic Dermatitis (PO-SCORAD), Self-Administered Eczema Area and Severity Index (SA-EASI) and adapted SA-EASI. ISS (paediatric version), POEM, PO-SCORAD, SA-EASI and adapted SA-EASI are currently the most appropriate instruments and therefore have the potential to be recommended as core symptom instrument in future clinical trials. These findings will be utilized for the development of a core outcome set for AE. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Predictive factors for the development of diabetes in women with previous gestational diabetes mellitus

    DEFF Research Database (Denmark)

    Damm, P.; Kühl, C.; Bertelsen, Aksel

    1992-01-01

    OBJECTIVES: The purpose of this study was to determine the incidence of diabetes in women with previous dietary-treated gestational diabetes mellitus and to identify predictive factors for development of diabetes. STUDY DESIGN: Two to 11 years post partum, glucose tolerance was investigated in 241...... women with previous dietary-treated gestational diabetes mellitus and 57 women without previous gestational diabetes mellitus (control group). RESULTS: Diabetes developed in 42 (17.4%) women with previous gestational diabetes mellitus (3.7% insulin-dependent diabetes mellitus and 13.7% non...... of previous patients with gestational diabetes mellitus in whom plasma insulin was measured during an oral glucose tolerance test in late pregnancy a low insulin response at diagnosis was found to be an independent predictive factor for diabetes development. CONCLUSIONS: Women with previous dietary...

  2. Evaluation of metal–nanowire electrical contacts by measuring contact end resistance

    International Nuclear Information System (INIS)

    Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung

    2012-01-01

    It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)

  3. Measurement, calculation and evaluation of photon production cross-sections

    International Nuclear Information System (INIS)

    Kocherov, N.P.

    1990-11-01

    The meeting proceedings were divided into three sessions devoted to the following topics: Experimental measurement and techniques (3 papers), calculation of photon cross-sections (9 papers), and evaluation (2 papers). A separate abstract was prepared for each of these papers. Refs, figs and tabs

  4. Measurement of cross-sections for the reaction 103Rh (n,n')103mRh in the energy range 5.69 - 12 MeV and its evaluation from the threshold up to 20 MeV

    International Nuclear Information System (INIS)

    Hossain, M.M.M.

    1995-05-01

    The cross-sections for the reaction 103 R(n,n') 103m Rh were measured by the method of activation in the neutron energy range 5.69-12.00 MeV produced by the D(d,n) 3 He reaction. The irradiation of Rh foils was performed at zero degree to the incident beam direction and the activities of KX-rays from the decay of 103m Rh were measured by means of a calibrated Si(Li) detector. During irradiation, the neutron fluence was measured with a fission chamber in which a thin deposit of 238 U was located immediately behind the Rh foil. The measured cross-section with the corresponding uncertainty in the stated energy range is more accurate than all previous measurements in spite of rather large corrections due to break-up neutrons. The update of the evaluation for the same reaction in the energy range from threshold up to 20 MeV was carried out by using the weighted average of cross-sections based on both the experimental data including the present one and theoretical model calculations. The experimental data were renormalized with respect to the recent precision KX-ray emission probability (7.66 + 0.14) % where necessary. To perform the evaluation, the whole excitation function was divided into 33 energy groups of 0.2-1.0 MeV widths. The uncertainties of the evaluated cross-sections especially 6-12 MeV have been improved due to the inclusion of the new measurement. Overall, the results of the updated evaluation are a considerable improvement compared to the previous evaluation of this reaction and also to the recommended cross-section data of IRDF (International Reactor Dosimetry File). (author)

  5. Measurement of self-evaluative motives: a shopping scenario.

    Science.gov (United States)

    Wajda, Theresa A; Kolbe, Richard; Hu, Michael Y; Cui, Annie Peng

    2008-08-01

    To develop measures of consumers' self-evaluative motives of Self-verification, Self-enhancement, and Self-improvement within the context of a mall shopping environment, an initial set of 49 items was generated by conducting three focus-group sessions. These items were subsequently converted into shopping-dependent motive statements. 250 undergraduate college students responded on a 7-point scale to each statement as these related to the acquisition of recent personal shopping goods. An exploratory factor analysis yielded five factors, accounting for 57.7% of the variance, three of which corresponded to the Self-verification motive (five items), Self-enhancement motive (three items), and Self-improvement motive (six items). These 14 items, along with 9 reconstructed items, yielded 23 items retained and subjected to additional testing. In a final round of data collection, 169 college students provided data for exploratory factor analysis. 11 items were used in confirmatory factor analysis. Analysis indicated that the 11-item scale adequately captured measures of the three self-evaluative motives. However, further data reduction produced a 9-item scale with marked improvement in statistical fit over the 11-item scale.

  6. Laparoscopy After Previous Laparotomy

    Directory of Open Access Journals (Sweden)

    Zulfo Godinjak

    2006-11-01

    Full Text Available Following the abdominal surgery, extensive adhesions often occur and they can cause difficulties during laparoscopic operations. However, previous laparotomy is not considered to be a contraindication for laparoscopy. The aim of this study is to present that an insertion of Veres needle in the region of umbilicus is a safe method for creating a pneumoperitoneum for laparoscopic operations after previous laparotomy. In the last three years, we have performed 144 laparoscopic operations in patients that previously underwent one or two laparotomies. Pathology of digestive system, genital organs, Cesarean Section or abdominal war injuries were the most common causes of previouslaparotomy. During those operations or during entering into abdominal cavity we have not experienced any complications, while in 7 patients we performed conversion to laparotomy following the diagnostic laparoscopy. In all patients an insertion of Veres needle and trocar insertion in the umbilical region was performed, namely a technique of closed laparoscopy. Not even in one patient adhesions in the region of umbilicus were found, and no abdominal organs were injured.

  7. Evaluation of the Wishart test statistics for polarimetric SAR data

    DEFF Research Database (Denmark)

    Skriver, Henning; Nielsen, Allan Aasbjerg; Conradsen, Knut

    2003-01-01

    A test statistic for equality of two covariance matrices following the complex Wishart distribution has previously been used in new algorithms for change detection, edge detection and segmentation in polarimetric SAR images. Previously, the results for change detection and edge detection have been...... quantitatively evaluated. This paper deals with the evaluation of segmentation. A segmentation performance measure originally developed for single-channel SAR images has been extended to polarimetric SAR images, and used to evaluate segmentation for a merge-using-moment algorithm for polarimetric SAR data....

  8. The efficacy of stuttering measurement training: evaluating two training programs.

    Science.gov (United States)

    Bainbridge, Lauren A; Stavros, Candace; Ebrahimian, Mineh; Wang, Yuedong; Ingham, Roger J

    2015-04-01

    Two stuttering measurement training programs currently used for training clinicians were evaluated for their efficacy in improving the accuracy of total stuttering event counting. Four groups, each with 12 randomly allocated participants, completed a pretest-posttest design training study. They were evaluated by their counts of stuttering events on eight 3-min audiovisual speech samples from adults and children who stutter. Stuttering judgment training involved use of either the Stuttering Measurement System (SMS), Stuttering Measurement Assessment and Training (SMAAT) programs, or no training. To test for the reliability of any training effect, SMS training was repeated with the 4th group. Both SMS-trained groups produced approximately 34% improvement, significantly better than no training or the SMAAT program. The SMAAT program produced a mixed result. The SMS program was shown to produce a "medium" effect size improvement in the accuracy of stuttering event counts, and this improvement was almost perfectly replicated in a 2nd group. Half of the SMAAT judges produced a 36% improvement in accuracy, but the other half showed no improvement. Additional studies are needed to demonstrate the durability of the reported improvements, but these positive effects justify the importance of stuttering measurement training.

  9. Initial evaluations of the use of microbial measures to quantify impact of acid rock drainage on the Finniss River (east branch)

    International Nuclear Information System (INIS)

    Holden, P.J.; Wilde, K.L.; Stone, D.J.; Ben-David, E.A.; Foster, L.J.

    2002-01-01

    Biological measures assessing the impact of pollution on aquatic ecosystems have been increasingly used over the last ten years to examine ecosystem health. The focus, however, has been on diversity and abundance of higher organisms, such as fish, frogs and macroinvertebrates, and it is desirable that such measures be made across all trophic levels of the ecosystem. In this study, phospholipid-fatty acid analysis and microbial carbon substrate utilisation assays (BIOLOG) of sediment and water samples were conducted to evaluate their usefulness as a measure of the effect of acid rock drainage (ARD) on the East Branch of the Finniss River. Both PLFA, and BIOLOG assays, generate data well suited to multivariate analysis and previous studies of the impact of ARD from the Brukunga mine (South Australia) have demonstrated the ability to distinguish between the effect of ARD, nutrients and dry-land salinity on microbial populations

  10. Do emotional intelligence and previous caring experience influence student nurse performance? A comparative analysis.

    Science.gov (United States)

    Stenhouse, Rosie; Snowden, Austyn; Young, Jenny; Carver, Fiona; Carver, Hannah; Brown, Norrie

    2016-08-01

    Reports of poor nursing care have focused attention on values based selection of candidates onto nursing programmes. Values based selection lacks clarity and valid measures. Previous caring experience might lead to better care. Emotional intelligence (EI) might be associated with performance, is conceptualised and measurable. To examine the impact of 1) previous caring experience, 2) emotional intelligence 3) social connection scores on performance and retention in a cohort of first year nursing and midwifery students in Scotland. A longitudinal, quasi experimental design. Adult and mental health nursing, and midwifery programmes in a Scottish University. Adult, mental health and midwifery students (n=598) completed the Trait Emotional Intelligence Questionnaire-short form and Schutte's Emotional Intelligence Scale on entry to their programmes at a Scottish University, alongside demographic and previous caring experience data. Social connection was calculated from a subset of questions identified within the TEIQue-SF in a prior factor and Rasch analysis. Student performance was calculated as the mean mark across the year. Withdrawal data were gathered. 598 students completed baseline measures. 315 students declared previous caring experience, 277 not. An independent-samples t-test identified that those without previous caring experience scored higher on performance (57.33±11.38) than those with previous caring experience (54.87±11.19), a statistically significant difference of 2.47 (95% CI, 0.54 to 4.38), t(533)=2.52, p=.012. Emotional intelligence scores were not associated with performance. Social connection scores for those withdrawing (mean rank=249) and those remaining (mean rank=304.75) were statistically significantly different, U=15,300, z=-2.61, p$_amp_$lt;0.009. Previous caring experience led to worse performance in this cohort. Emotional intelligence was not a useful indicator of performance. Lower scores on the social connection factor were associated

  11. Chinese Middle School Teachers' Preferences Regarding Performance Evaluation Measures

    Science.gov (United States)

    Liu, Shujie; Xu, Xianxuan; Stronge, James H.

    2016-01-01

    Teacher performance evaluation currently is receiving unprecedented attention from policy makers, scholars, and practitioners worldwide. This study is one of the few studies of teacher perceptions regarding teacher performance measures that focus on China. We employed a quantitative dominant mixed research design to investigate Chinese teachers'…

  12. History and status of atomic mass measurement and evaluation

    International Nuclear Information System (INIS)

    Huang Wenxue; Zhu Zhichao; Wang Meng; Wang Yue; Tian Yulin; Xu Hushan; Xiao Guoqing

    2010-01-01

    Mass is one of the most fundamental properties that can be obtained about an atomic nucleus. High-accuracy mass values for atoms let us study the atomic and nuclear binding energies that represent the sum of all the atomic and nucleonic interactions. Looking on the history of nuclear masses, it can be found that it is almost as old as that of nuclear physics itself. The experimental methods for masses and the relevant outcomes are so rich that the evaluation is needed to check the consistency among the various results and obtain more reliable data. The atomic mass evaluation is a considerate and complicated process. This paper introduces briefly the history and status of atomic mass measurement and evaluation. (authors)

  13. Monte Carlo evaluation of derivative-based global sensitivity measures

    International Nuclear Information System (INIS)

    Kucherenko, S.; Rodriguez-Fernandez, M.; Pantelides, C.; Shah, N.

    2009-01-01

    A novel approach for evaluation of derivative-based global sensitivity measures (DGSM) is presented. It is compared with the Morris and the Sobol' sensitivity indices methods. It is shown that there is a link between DGSM and Sobol' sensitivity indices. DGSM are very easy to implement and evaluate numerically. The computational time required for numerical evaluation of DGSM is many orders of magnitude lower than that for estimation of the Sobol' sensitivity indices. It is also lower than that for the Morris method. Efficiencies of Monte Carlo (MC) and quasi-Monte Carlo (QMC) sampling methods for calculation of DGSM are compared. It is shown that the superiority of QMC over MC depends on the problem's effective dimension, which can also be estimated using DGSM.

  14. Evaluation of Wavelet-based Core Inflation Measures: Evidence from Peru

    OpenAIRE

    Erick Lahura; Marco Vega

    2011-01-01

    Under inflation targeting and other related monetary policy regimes, the identication of non-transitory inflation and forecasts about future inflation constitute key ingredients for monetary policy decisions. In practice, central banks perform these tasks using so-called "core inflation measures". In this paper we construct alternative core inflation measures using wavelet functions and multiresolution analysis (MRA), and then evaluate their relevance for monetary policy. The construction of ...

  15. Evaluation of uncertainty and detection limits in radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain); Idoeta, R. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)], E-mail: raquel.idoeta@ehu.es; Legarda, F. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)

    2008-10-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories.

  16. Evaluation of uncertainty and detection limits in radioactivity measurements

    International Nuclear Information System (INIS)

    Herranz, M.; Idoeta, R.; Legarda, F.

    2008-01-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories

  17. Evaluation of Intersection Traffic Control Measures through Simulation

    Science.gov (United States)

    Asaithambi, Gowri; Sivanandan, R.

    2015-12-01

    Modeling traffic flow is stochastic in nature due to randomness in variables such as vehicle arrivals and speeds. Due to this and due to complex vehicular interactions and their manoeuvres, it is extremely difficult to model the traffic flow through analytical methods. To study this type of complex traffic system and vehicle interactions, simulation is considered as an effective tool. Application of homogeneous traffic models to heterogeneous traffic may not be able to capture the complex manoeuvres and interactions in such flows. Hence, a microscopic simulation model for heterogeneous traffic is developed using object oriented concepts. This simulation model acts as a tool for evaluating various control measures at signalized intersections. The present study focuses on the evaluation of Right Turn Lane (RTL) and Channelised Left Turn Lane (CLTL). A sensitivity analysis was performed to evaluate RTL and CLTL by varying the approach volumes, turn proportions and turn lane lengths. RTL is found to be advantageous only up to certain approach volumes and right-turn proportions, beyond which it is counter-productive. CLTL is found to be advantageous for lower approach volumes for all turn proportions, signifying the benefits of CLTL. It is counter-productive for higher approach volume and lower turn proportions. This study pinpoints the break-even points for various scenarios. The developed simulation model can be used as an appropriate intersection lane control tool for enhancing the efficiency of flow at intersections. This model can also be employed for scenario analysis and can be valuable to field traffic engineers in implementing vehicle-type based and lane-based traffic control measures.

  18. Validation of the Online version of the Previous Day Food Questionnaire for schoolchildren

    Directory of Open Access Journals (Sweden)

    Raquel ENGEL

    Full Text Available ABSTRACT Objective To evaluate the validity of the web-based version of the Previous Day Food Questionnaire Online for schoolchildren from the 2nd to 5th grades of elementary school. Methods Participants were 312 schoolchildren aged 7 to 12 years of a public school from the city of Florianópolis, Santa Catarina, Brazil. Validity was assessed by sensitivity, specificity, as well as by agreement rates (match, omission, and intrusion rates of food items reported by children on the Previous Day Food Questionnaire Online, using direct observation of foods/beverages eaten during school meals (mid-morning snack or afternoon snack on the previous day as the reference. Multivariate multinomial logistic regression analysis was used to evaluate the influence of participants’ characteristics on omission and intrusion rates. Results The results showed adequate sensitivity (67.7% and specificity (95.2%. There were low omission and intrusion rates of 22.8% and 29.5%, respectively when all food items were analyzed. Pizza/hamburger showed the highest omission rate, whereas milk and milk products showed the highest intrusion rate. The participants who attended school in the afternoon shift presented a higher probability of intrusion compared to their peers who attended school in the morning. Conclusion The Previous Day Food Questionnaire Online possessed satisfactory validity for the assessment of food intake at the group level in schoolchildren from the 2nd to 5th grades of public school.

  19. Performance evaluation of activimeter for PET radiopharmaceutical measuring based on 18F

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Mercia Liane de; Lima, Fernando Roberto de Andrade

    2014-01-01

    Proficiency test is an essential tool to assess the reliability and accuracy of measurements. In this work, proficiency tests (Z-score, accuracy and relative deviation) were applied to evaluate the performance of the activimeter used at Radiopharmaceuticals Production Division of the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN). The results were evaluated in compliance with ISO/IEC Guide 43-1. Additionally, correction factors for different measurement geometries were determined experimentally for those devices. (author)

  20. Evaluation of pesticide safety measures adopted by potato farmers ...

    African Journals Online (AJOL)

    In order to increase productivity and quality, farmers use pesticides and other agrochemicals. These pesticides if improperly handled impact negatively on the health of the users. The objective of the study was to evaluate the pesticide safety measures adopted by potato farmers in Chebiemit Division of Elgeyo/Marakwet ...

  1. Evaluation of pump characteristic from measurement of fast deceleration

    Directory of Open Access Journals (Sweden)

    Himr Daniel

    2015-01-01

    Full Text Available Article describes an experiment where a pump connected to the simple hydraulic circuit is decelerated. Since the deceleration is fast enough the operating point of the machine moves from the initial steady position to the breaking zone, turbine zone and back to the new steady position. A dependence of the specific energy and the torque on the flow rate was evaluated from the measurement of the input and output pressure, torque and rotational speed recorded during the deceleration. Obtained characteristic is much wider than curves obtained from regular measurement of steady state.

  2. Health related quality of life measures in Arabic speaking populations: a systematic review on cross-cultural adaptation and measurement properties.

    Science.gov (United States)

    Al Sayah, Fatima; Ishaque, Sana; Lau, Darren; Johnson, Jeffrey A

    2013-02-01

    This systematic review was conducted to identify generic health related quality of life (HRQL) measures translated into Arabic, and evaluate their cross-cultural adaptation and measurement properties. Six databases were searched, relevant journals were hand searched, and reference lists of included studies were reviewed. Previously established criteria were used to evaluate the cross-cultural adaptation of the identified instruments and their measurement properties. Twenty studies that reported the Arabic translations and adaptations of HRQL measures and/or their measurement properties were included in this review. The identified instruments were SF-36, RAND-36, WHOQOL-Bref, COOP/WONCA charts, EQ-5D, and QLI. Cross-cultural adaptations of all measures were of moderate to good quality, and evaluation of measurement properties was limited due to insufficiency of evidence. Based on cross-cultural adaptation evaluation, each instrument is more applicable to the population for whom it was adapted, and to other Arabic populations of similar culture and language specific idioms. This review facilitates the selection among existing Arabic versions of generic HRQL for use in particular Arabic countries. However, each of the translated versions requires further investigation of measurement properties before more concrete recommendations could be made.

  3. Association of single nucleotide polymorphisms in candidate genes previously related to genetic variation in fertility with phenotypic measurements of reproductive function in Holstein cows.

    Science.gov (United States)

    Ortega, M Sofia; Denicol, Anna C; Cole, John B; Null, Daniel J; Taylor, Jeremy F; Schnabel, Robert D; Hansen, Peter J

    2017-05-01

    Many genetic markers related to health or production traits are not evaluated in populations independent of the discovery population or related to phenotype. Here we evaluated 68 single nucleotide polymorphisms (SNP) in candidate genes previously associated with genetic merit for fertility and production traits for association with phenotypic measurements of fertility in a population of Holstein cows that was selected based on predicted transmitting ability (PTA) for daughter pregnancy rate (DPR; high, ≥1, n = 989; low, ≤ -1.0, n = 1,285). Cows with a high PTA for DPR had higher pregnancy rate at first service, fewer services per conception, and fewer days open than cows with a low PTA for DPR. Of the 68 SNP, 11 were associated with pregnancy rate at first service, 16 with services per conception, and 19 with days open. Single nucleotide polymorphisms in 12 genes (BDH2, BSP3, CAST, CD2, CD14, FUT1, FYB, GCNT3, HSD17B7, IBSP, OCLN, and PCCB) had significant associations with 2 fertility traits, and SNP in 4 genes (CSPP1, FCER1G, PMM2, and TBC1D24) had significant associations with each of the 3 traits. Results from this experiment were compared with results from 2 earlier studies in which the SNP were associated with genetic estimates of fertility. One study involved the same animals as used here, and the other study was of an independent population of bulls. A total of 13 SNP associated with 1 or more phenotypic estimates of fertility were directionally associated with genetic estimates of fertility in the same cow population. Moreover, 14 SNP associated with reproductive phenotype were directionally associated with genetic estimates of fertility in the bull population. Nine SNP (located in BCAS, BSP3, CAST, FUT1, HSD17B7, OCLN, PCCB, PMM2, and TBC1D24) had a directional association with fertility in all 3 studies. Examination of the function of the genes with SNP associated with reproduction in more than one study indicates the importance of steroid hormones

  4. Volatile Organic Compounds (VOCs) Measurements in Karachi, Pakistan (2006): a Comparison With Previous Urban Sampling Campaigns Worldwide.

    Science.gov (United States)

    Barletta, B.; Meinardi, S.; Khwaja, H. A.; Beyersdorf, A. J.; Baker, A. K.; Zou, S.; Rowland, F.; Blake, D. R.

    2008-12-01

    Mixing ratios of carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), and 47 nonmethane hydrocarbons - NMHCs - (19 alkanes, 13 alkenes, ethyne, and 14 aromatics) were determined for ground level whole air samples collected during the winter of 2006 in Karachi, Pakistan. Pakistan is among the fastest growing economies in Asia, and Karachi is one of the largest cities in the world with a rapidly expanding population of over 14 million in the whole metropolitan area, and a large industrial base. Samples were collected in January 2006 throughout the urban area to characterize the overall air composition of the city, and along the busiest road to determine the traffic signature of Karachi. This sampling campaign follows a previous study carried out in the winter of 1998-1999 in the same city, when elevated concentrations of many NMHCs were observed. Exceptionally high levels of methane were still observed in 2006 with an average mixing ratio of 5.0 ppmv (6.3 ppmv were observed in 1999). The overall air composition of the Karachi urban environment characterized during this 2006 sampling is compared to 1999 aiming to highlight any possible change in the main VOC sources present throughout the city. In particular, we want to evaluate the impact of the heavy usage of natural gas on the overall air quality of Karachi and the recently increased use of liquefied petroleum gas (LPG) as alternative source of energy. We also compare the composition of the urban troposphere of Karachi to other major urban centers worldwide such as Guangzhou (China), Mexico City (Mexico), and Milan (Italy).

  5. Evaluation method of lead measurement accuracy of gears using a wedge artefact

    International Nuclear Information System (INIS)

    Komori, Masaharu; Takeoka, Fumi; Kubo, Aizoh; Okamoto, Kazuhiko; Osawa, Sonko; Sato, Osamu; Takatsuji, Toshiyuki

    2009-01-01

    The reduction of the vibration and noise of gears is an important issue in mechanical devices such as vehicles and wind turbines. The characteristics of the vibration and noise of gears are markedly affected by deviations of the tooth flank form of micrometre order; therefore, a strict quality control of the tooth flank form is required. The accuracy of the lead measurement for a gear-measuring instrument is usually evaluated using a master gear or a lead master. However, it is difficult to manufacture masters with high accuracy because the helix is a complicated geometrical form. In this paper, we propose a method of evaluating a gear-measuring instrument using a wedge artefact, which includes a highly precise plane surface. The concept of the wedge artefact is described and a mathematical model of the measuring condition of the wedge artefact is constructed. Theoretical measurement results for the wedge artefact are calculated. The wedge artefact is designed and produced on the basis of the theoretical measurement results. A measurement experiment using the wedge artefact is carried out and its effectiveness is verified

  6. Compilation and evaluation of fission yield nuclear data

    International Nuclear Information System (INIS)

    Lammer, M.

    1991-09-01

    The task of this meeting was to review the progress made since the previous meeting on fission yield evaluation and to define the tasks for an IAEA Co-ordinated Research Programme in detail. Improvements have been noted in measured data, model calculations and the situation of fission yield evaluation. Tabs

  7. MCNP HPGe detector benchmark with previously validated Cyltran model.

    Science.gov (United States)

    Hau, I D; Russ, W R; Bronson, F

    2009-05-01

    An exact copy of the detector model generated for Cyltran was reproduced as an MCNP input file and the detection efficiency was calculated similarly with the methodology used in previous experimental measurements and simulation of a 280 cm(3) HPGe detector. Below 1000 keV the MCNP data correlated to the Cyltran results within 0.5% while above this energy the difference between MCNP and Cyltran increased to about 6% at 4800 keV, depending on the electron cut-off energy.

  8. Evaluating the Psychometric Quality of Social Skills Measures: A Systematic Review.

    Science.gov (United States)

    Cordier, Reinie; Speyer, Renée; Chen, Yu-Wei; Wilkes-Gillan, Sarah; Brown, Ted; Bourke-Taylor, Helen; Doma, Kenji; Leicht, Anthony

    2015-01-01

    Impairments in social functioning are associated with an array of adverse outcomes. Social skills measures are commonly used by health professionals to assess and plan the treatment of social skills difficulties. There is a need to comprehensively evaluate the quality of psychometric properties reported across these measures to guide assessment and treatment planning. To conduct a systematic review of the literature on the psychometric properties of social skills and behaviours measures for both children and adults. A systematic search was performed using four electronic databases: CINAHL, PsycINFO, Embase and Pubmed; the Health and Psychosocial Instruments database; and grey literature using PsycExtra and Google Scholar. The psychometric properties of the social skills measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria. Thirty-Six studies and nine manuals were included to assess the psychometric properties of thirteen social skills measures that met the inclusion criteria. Most measures obtained excellent overall methodological quality scores for internal consistency and reliability. However, eight measures did not report measurement error, nine measures did not report cross-cultural validity and eleven measures did not report criterion validity. The overall quality of the psychometric properties of most measures was satisfactory. The SSBS-2, HCSBS and PKBS-2 were the three measures with the most robust evidence of sound psychometric quality in at least seven of the eight psychometric properties that were appraised. A universal working definition of social functioning as an overarching construct is recommended. There is a need for ongoing research in the area of the psychometric properties of social skills and behaviours instruments.

  9. Evaluating the Psychometric Quality of Social Skills Measures: A Systematic Review

    Science.gov (United States)

    Brown, Ted; Bourke-Taylor, Helen; Doma, Kenji; Leicht, Anthony

    2015-01-01

    Introduction Impairments in social functioning are associated with an array of adverse outcomes. Social skills measures are commonly used by health professionals to assess and plan the treatment of social skills difficulties. There is a need to comprehensively evaluate the quality of psychometric properties reported across these measures to guide assessment and treatment planning. Objective To conduct a systematic review of the literature on the psychometric properties of social skills and behaviours measures for both children and adults. Methods A systematic search was performed using four electronic databases: CINAHL, PsycINFO, Embase and Pubmed; the Health and Psychosocial Instruments database; and grey literature using PsycExtra and Google Scholar. The psychometric properties of the social skills measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria. Results Thirty-Six studies and nine manuals were included to assess the psychometric properties of thirteen social skills measures that met the inclusion criteria. Most measures obtained excellent overall methodological quality scores for internal consistency and reliability. However, eight measures did not report measurement error, nine measures did not report cross-cultural validity and eleven measures did not report criterion validity. Conclusions The overall quality of the psychometric properties of most measures was satisfactory. The SSBS-2, HCSBS and PKBS-2 were the three measures with the most robust evidence of sound psychometric quality in at least seven of the eight psychometric properties that were appraised. A universal working definition of social functioning as an overarching construct is recommended. There is a need for ongoing research in the area of the psychometric properties of social skills and behaviours instruments. PMID:26151362

  10. Evaluating the Psychometric Quality of Social Skills Measures: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Reinie Cordier

    Full Text Available Impairments in social functioning are associated with an array of adverse outcomes. Social skills measures are commonly used by health professionals to assess and plan the treatment of social skills difficulties. There is a need to comprehensively evaluate the quality of psychometric properties reported across these measures to guide assessment and treatment planning.To conduct a systematic review of the literature on the psychometric properties of social skills and behaviours measures for both children and adults.A systematic search was performed using four electronic databases: CINAHL, PsycINFO, Embase and Pubmed; the Health and Psychosocial Instruments database; and grey literature using PsycExtra and Google Scholar. The psychometric properties of the social skills measures were evaluated against the COSMIN taxonomy of measurement properties using pre-set psychometric criteria.Thirty-Six studies and nine manuals were included to assess the psychometric properties of thirteen social skills measures that met the inclusion criteria. Most measures obtained excellent overall methodological quality scores for internal consistency and reliability. However, eight measures did not report measurement error, nine measures did not report cross-cultural validity and eleven measures did not report criterion validity.The overall quality of the psychometric properties of most measures was satisfactory. The SSBS-2, HCSBS and PKBS-2 were the three measures with the most robust evidence of sound psychometric quality in at least seven of the eight psychometric properties that were appraised. A universal working definition of social functioning as an overarching construct is recommended. There is a need for ongoing research in the area of the psychometric properties of social skills and behaviours instruments.

  11. Homicide and domestic violence. Are there different psychological profiles mediated by previous exerted on the victim?

    OpenAIRE

    Montserrat Yepes; Maria R. Vinas; Inmaculada Armadans; Miguel A. Soria

    2009-01-01

    A sample of 46 men was evaluated with the DAPP (Questionnaire of Domestic Aggressor Psychological Profile). All were inmates convicted for various degrees of violence against their wives in different prisons. The sample was divided into three groups: homicides without previous violence against their wives (H) (n=11), homicides with previous violence (VH) (n=9) and domestic batterers without previous homicide attempts against their partners (B) (n=26). The aim of the study was to analyze the p...

  12. Methods, measures and indicators for evaluating benefits of transportation research

    CSIR Research Space (South Africa)

    Du Plessis, Louw

    2016-04-01

    Full Text Available The purpose of this article is to provide updated information by identifying and discussing methods, measures and indicators for evaluating benefits appropriate for transportation-related research facilities/programmes. The information has been...

  13. Monte Carlo evaluation of derivative-based global sensitivity measures

    Energy Technology Data Exchange (ETDEWEB)

    Kucherenko, S. [Centre for Process Systems Engineering, Imperial College London, London SW7 2AZ (United Kingdom)], E-mail: s.kucherenko@ic.ac.uk; Rodriguez-Fernandez, M. [Process Engineering Group, Instituto de Investigaciones Marinas, Spanish Council for Scientific Research (C.S.I.C.), C/ Eduardo Cabello, 6, 36208 Vigo (Spain); Pantelides, C.; Shah, N. [Centre for Process Systems Engineering, Imperial College London, London SW7 2AZ (United Kingdom)

    2009-07-15

    A novel approach for evaluation of derivative-based global sensitivity measures (DGSM) is presented. It is compared with the Morris and the Sobol' sensitivity indices methods. It is shown that there is a link between DGSM and Sobol' sensitivity indices. DGSM are very easy to implement and evaluate numerically. The computational time required for numerical evaluation of DGSM is many orders of magnitude lower than that for estimation of the Sobol' sensitivity indices. It is also lower than that for the Morris method. Efficiencies of Monte Carlo (MC) and quasi-Monte Carlo (QMC) sampling methods for calculation of DGSM are compared. It is shown that the superiority of QMC over MC depends on the problem's effective dimension, which can also be estimated using DGSM.

  14. Evaluation of Uranium-235 Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaspar, Tiffany C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dibert, Mark W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-23

    Monolithic U-Mo fuel plates are rolled to final fuel element form from the original cast ingot, and thus any inhomogeneities in 235U distribution present in the cast ingot are maintained, and potentially exaggerated, in the final fuel foil. The tolerance for inhomogeneities in the 235U concentration in the final fuel element foil is very low. A near-real-time, nondestructive technique to evaluate the 235U distribution in the cast ingot is required in order to provide feedback to the casting process. Based on the technical analysis herein, gamma spectroscopy has been recommended to provide a near-real-time measure of the 235U distribution in U-Mo cast plates.

  15. Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study

    International Nuclear Information System (INIS)

    Tan, Sovira; Ward, Michael M; Yao Jianhua; Yao, Lawrence

    2012-01-01

    Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies. (paper)

  16. Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study

    Science.gov (United States)

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Ward, Michael M.

    2012-07-01

    Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies.

  17. Measurement and Evaluation of Wear Frogs Switches ŽSR

    Directory of Open Access Journals (Sweden)

    Urda Ján

    2014-05-01

    Full Text Available This paper deals with the measurement and evaluation of wear frogs switches ZSR. One of the main problems is the oversize wear. The possibilities analysis of this problem is offered through a set of switches and monitoring of selected parameters. One of these parameters is also monitoring the vertical wear

  18. Evaluation of Routine Atmospheric Sounding Measurements Using Unmanned Systems (ERASMUS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    de Boer, Gijs [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Lawrence, Dale [Univ. of Colorado, Boulder, CO (United States); Palo, Scott [Univ. of Colorado, Boulder, CO (United States); Argrow, Brian [Univ. of Colorado, Boulder, CO (United States); LoDolce, Gabriel [Univ. of Colorado, Boulder, CO (United States); Curry, Nathan [Univ. of Colorado, Boulder, CO (United States); Weibel, Douglas [Univ. of Colorado, Boulder, CO (United States); Finnamore, W [Univ. of Colorado, Boulder, CO (United States); D' Amore, P [Univ. of Colorado, Boulder, CO (United States); Borenstein, Steven [Univ. of Colorado, Boulder, CO (United States); Nichols, Tevis [Univ. of Colorado, Boulder, CO (United States); Elston, Jack [Blackswift Technologies, Boulder, CO (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bendure, Al [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Long, Chuck [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Telg, Hagen [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Gao, Rushan [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Hock, T [National Center for Atmospheric Research, Boulder, CO (United States); Bland, Geoff [National Aeronautics and Space Administration (NASA), Washington, DC (United States)

    2017-03-01

    The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) campaign was proposed with two central goals; to obtain scientifically relevant measurements of quantities related to clouds, aerosols, and radiation, including profiles of temperature, humidity, and aerosol particles, the structure of the arctic atmosphere during transitions between clear and cloudy states, measurements that would allow us to evaluate the performance of retrievals from U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility remote sensors in the Arctic atmosphere, and information on the spatial variability of heat and moisture fluxes from the arctic surface; and to demonstrate unmanned aerial system (UAS) capabilities in obtaining measurements relevant to the ARM and ASR programs, particularly for improving our understanding of Arctic clouds and aerosols.

  19. Research on uncertainty evaluation measure and method of voltage sag severity

    Science.gov (United States)

    Liu, X. N.; Wei, J.; Ye, S. Y.; Chen, B.; Long, C.

    2018-01-01

    Voltage sag is an inevitable serious problem of power quality in power system. This paper focuses on a general summarization and reviews on the concepts, indices and evaluation methods about voltage sag severity. Considering the complexity and uncertainty of influencing factors, damage degree, the characteristics and requirements of voltage sag severity in the power source-network-load sides, the measure concepts and their existing conditions, evaluation indices and methods of voltage sag severity have been analyzed. Current evaluation techniques, such as stochastic theory, fuzzy logic, as well as their fusion, are reviewed in detail. An index system about voltage sag severity is provided for comprehensive study. The main aim of this paper is to propose thought and method of severity research based on advanced uncertainty theory and uncertainty measure. This study may be considered as a valuable guide for researchers who are interested in the domain of voltage sag severity.

  20. Intercomparison of measuring and evaluation methods for environmental radiations

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Nagaoka, Toshi; Sakamoto, Ryuichi; Tsutsumi, Masahiro; Moriuchi, Shigeru; Okano, Masaharu.

    1990-11-01

    This report presents the results of the cooperative research by IPCR and JAERI. In order to investigate the accuracy and characteristics of the measurement and evaluation methods for environmental radiations, developed independently by IPCR and by JAERI, field experiments were performed using the both methods under the same conditions at the same time. The experiments were performed at fixed points on the ground, in a moving car and in a flying helicopter. Discussion was made on the basis of the comparison of the results from the both methods. The exposure rates from the IPCR method agreed within 10% with those from the JAERI method, however the former were systematically higher than the latter. Since the evaluated exposure rate components due to 238 U-series, 232 Th-series and 40 K showed apparent differences between the IPCR method and the JAERI method, further investigation is necessary for the positions and widths of the applied energy bands and the coefficients in the equations to evaluate the components. In measurements in a moving vehicle, the sequential data should be gathered per sufficiently short distance to distinguish the local change of the radiation level when it changes greatly according to the location. The aerial data showed that the exposure rates from terrestrial gamma rays in the region west of the Abe river are apparently higher than those in the Kanto district. (author)

  1. Evaluating airline energy efficiency: An integrated approach with Network Epsilon-based Measure and Network Slacks-based Measure

    International Nuclear Information System (INIS)

    Xu, Xin; Cui, Qiang

    2017-01-01

    This paper focuses on evaluating airline energy efficiency, which is firstly divided into four stages: Operations Stage, Fleet Maintenance Stage, Services Stage and Sales Stage. The new four-stage network structure of airline energy efficiency is a modification of existing models. A new approach, integrated with Network Epsilon-based Measure and Network Slacks-based Measure, is applied to assess the overall energy efficiency and divisional efficiency of 19 international airlines from 2008 to 2014. The influencing factors of airline energy efficiency are analyzed through the regression analysis. The results indicate the followings: 1. The integrated model can identify the benchmarking airlines in the overall system and stages. 2. Most airlines' energy efficiencies keep steady during the period, except for some sharply fluctuations. The efficiency decreases mainly centralized in the year 2008–2011, affected by the financial crisis in the USA. 3. The average age of fleet is positively correlated with the overall energy efficiency, and each divisional efficiency has different significant influencing factors. - Highlights: • An integrated approach with Network Epsilon-based Measure and Network Slacks-based Measure is developed. • 19 airlines' energy efficiencies are evaluated. • Garuda Indonesia has the highest overall energy efficiency.

  2. Evaluation of animal control measures on pet demographics in Santa Clara County, California, 1993-2006.

    Science.gov (United States)

    Kass, Philip H; Johnson, Karen L; Weng, Hsin-Yi

    2013-01-01

    The measurable benefits of animal control programs are unknown and the aim of this study was to determine the impact of these programs on pet population changes. A prospective cross-sectional study of 1000 households was implemented in 2005 to evaluate characteristics of the owned and unowned population of dogs and cats in Santa Clara County, California. The same population was previously studied 12 years earlier. During this time period, the county instituted in 1994 and then subsequently disestablished a municipal spay/neuter voucher program for cats. Dog intakes declined from 1992-2005, as they similarly did for an adjacent county (San Mateo). However, cat intakes declined significantly more in Santa Clara County than San Mateo, with an average annual decline of approximately 700 cats for the 12 year period. Time series analysis showed a greater than expected decline in the number of cats surrendered to shelters in Santa Clara County during the years the voucher program was in effect (1994-2005). The net savings to the county by reducing the number of cat shelter intakes was estimated at approximately $1.5 million. The measurable benefits of animal control programs are unknown and the aim of this study was to determine the impact of these programs on pet population changes.

  3. Midterm Stability Evaluation of Wide-area Power System by using Synchronized Phasor Measurements

    Science.gov (United States)

    Ota, Yutaka; Ukai, Hiroyuki; Nakamura, Koichi; Fujita, Hideki

    In recent years, the PMU (Phasor Measurement Unit) receives a great deal of attention as a synchronized measurement system of power systems. Synchronized phasor angles obtained by the PMU provide the effective information for evaluating the stability of a bulk power system. The aspect of instability phenomena during midterm tends to be more complicated, and the stability analysis using the synchronized phasor measurements is significant in order to keep a complicated power system stable. This paper proposes a midterm stability evaluation method of the wide-area power system by using the synchronized phasor measurements. By clustering and aggregating the power system to some coherent groups, the step-out is effectively predicted on the basis of the two-machine equivalent power system model. The midterm stability of a longitudinal power system model of Japanese 60Hz systems constructed by the PSA, which is a hybrid-type power system simulator, is practically evaluated using the proposed method.

  4. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    Science.gov (United States)

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  5. Evaluation of three different measurement methods for dural ectasia in Marfan syndrome

    International Nuclear Information System (INIS)

    Weigang, E.; Ghanem, N.; Chang, X.-C.; Richter, H.; Frydrychowicz, A.; Szabo, G.; Dudeck, O.; Knirsch, W.; Samson, P. von; Langer, M.; Beyersdorf, F.

    2006-01-01

    Aim: Dural ectasia is a major diagnostic criterion for Marfan syndrome using the Ghent nosology. Our aim was to evaluate the efficacy of three different radiological methods previously proposed for the assessment of dural sac diameter in Marfan syndrome. Methods: Marfan syndrome was diagnosed in our study using the Ghent criteria, disregarding dural ectasia as a criterion. Three proposed radiological methods were applied to measure dural sac diameter, examined for 41 patients (18 patients with and 23 without Marfan syndrome) by computed tomography or magnetic resonance imaging. Results: Using Oosterhof's method, 94% of the patients with and 44% of the patients without Marfan syndrome fulfilled the criteria of dural ectasia. According to Villeirs, dural ectasia was diagnosed in 18% of the patients with and in none of the patients without Marfan syndrome. With Ahn's method, dural ectasia was found in 72% of the patients with and in 44% of the patients without Marfan syndrome. In only two patients with Marfan syndrome was dural ectasia diagnosed by all three methods. Conclusion: Our results reveal overt discrepancy between the three methods of assessing dural ectasia. Considering the key role played by dural ectasia in reinforcing the diagnosis of Marfan syndrome according to the Ghent nosology, a standardized and reliable method should be sought

  6. Evaluation of three different measurement methods for dural ectasia in Marfan syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Weigang, E.; Ghanem, N.; Chang, X.-C.; Richter, H.; Frydrychowicz, A.; Szabo, G.; Dudeck, O.; Knirsch, W.; Samson, P. von; Langer, M.; Beyersdorf, F

    2006-11-15

    Aim: Dural ectasia is a major diagnostic criterion for Marfan syndrome using the Ghent nosology. Our aim was to evaluate the efficacy of three different radiological methods previously proposed for the assessment of dural sac diameter in Marfan syndrome. Methods: Marfan syndrome was diagnosed in our study using the Ghent criteria, disregarding dural ectasia as a criterion. Three proposed radiological methods were applied to measure dural sac diameter, examined for 41 patients (18 patients with and 23 without Marfan syndrome) by computed tomography or magnetic resonance imaging. Results: Using Oosterhof's method, 94% of the patients with and 44% of the patients without Marfan syndrome fulfilled the criteria of dural ectasia. According to Villeirs, dural ectasia was diagnosed in 18% of the patients with and in none of the patients without Marfan syndrome. With Ahn's method, dural ectasia was found in 72% of the patients with and in 44% of the patients without Marfan syndrome. In only two patients with Marfan syndrome was dural ectasia diagnosed by all three methods. Conclusion: Our results reveal overt discrepancy between the three methods of assessing dural ectasia. Considering the key role played by dural ectasia in reinforcing the diagnosis of Marfan syndrome according to the Ghent nosology, a standardized and reliable method should be sought.

  7. Application-Driven Reliability Measures and Evaluation Tool for Fault-Tolerant Real-Time Systems

    National Research Council Canada - National Science Library

    Krishna, C

    2001-01-01

    .... The measure combines graphic-theoretic concepts in evaluating the underlying reliability of the network and other means to evaluate the ability of the network to support interprocessor traffic...

  8. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation

    International Nuclear Information System (INIS)

    Berico, M.; Castellani, C. M.; Formignani, M.; Mariotti, F.

    2001-01-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F e q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F e q, f p ) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented [it

  9. Acceptability of the Risk Importance Measures in Evaluation of a Change

    International Nuclear Information System (INIS)

    Dimitrijevic, V. B.; Chapman, J. R.

    1996-01-01

    In this paper, the authors discuss insights gained from evaluating changes to plant design and operational practices. Evaluation of a change is performed in order to provide an answer to two fundamental questions: what is the impact and is the impact acceptable? In order to determine 'the acceptability of an impact', the risk-based technologies today provide various ranking schemes. They are based on the existing IPE studies or PSA models and use of standard risk importance measures. In 'ad hoc' applications of risk importance measures, the specific nature of the analyzed change is often neglected. This paper attempts to capture the most common problems in the application of importance measures, and defines the limits of this application. The authors' position is that the use of risk importance information as the sole basis to accept or reject with ranking results, after the basis for the rank is meaningfully established. (author)

  10. Invited Article: Concepts and tools for the evaluation of measurement uncertainty

    Science.gov (United States)

    Possolo, Antonio; Iyer, Hari K.

    2017-01-01

    Measurements involve comparisons of measured values with reference values traceable to measurement standards and are made to support decision-making. While the conventional definition of measurement focuses on quantitative properties (including ordinal properties), we adopt a broader view and entertain the possibility of regarding qualitative properties also as legitimate targets for measurement. A measurement result comprises the following: (i) a value that has been assigned to a property based on information derived from an experiment or computation, possibly also including information derived from other sources, and (ii) a characterization of the margin of doubt that remains about the true value of the property after taking that information into account. Measurement uncertainty is this margin of doubt, and it can be characterized by a probability distribution on the set of possible values of the property of interest. Mathematical or statistical models enable the quantification of measurement uncertainty and underlie the varied collection of methods available for uncertainty evaluation. Some of these methods have been in use for over a century (for example, as introduced by Gauss for the combination of mutually inconsistent observations or for the propagation of "errors"), while others are of fairly recent vintage (for example, Monte Carlo methods including those that involve Markov Chain Monte Carlo sampling). This contribution reviews the concepts, models, methods, and computations that are commonly used for the evaluation of measurement uncertainty, and illustrates their application in realistic examples drawn from multiple areas of science and technology, aiming to serve as a general, widely accessible reference.

  11. Is Cup Positioning Challenged in Hips Previously Treated With Periacetabular Osteotomy?

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Stilling, Maiken; Søballe, Kjeld

    2014-01-01

    After periacetabular osteotomy (PAO), some patients develop osteoarthritis with need of a total hip arthroplasty (THA). We evaluated the outcome of THA following PAO and explored factors associated with inferior cup position and increased polyethylene wear. Follow-up were performed 4 to 10years...... after THA in 34 patients (38 hips) with previous PAO. Computer analysis evaluated cup position and wear rates. No patient had dislocations or revision surgery. Median scores were: Harris hip 96, Oxford hip 38 and WOMAC 78. Mean cup anteversion and abduction angles were 22(o) (range 7°-43°) and 45......° (range 28°-65°). Outliers of cup abduction were associated with persisting dysplasia (CE...

  12. Local difference measures between complex networks for dynamical system model evaluation.

    Science.gov (United States)

    Lange, Stefan; Donges, Jonathan F; Volkholz, Jan; Kurths, Jürgen

    2015-01-01

    A faithful modeling of real-world dynamical systems necessitates model evaluation. A recent promising methodological approach to this problem has been based on complex networks, which in turn have proven useful for the characterization of dynamical systems. In this context, we introduce three local network difference measures and demonstrate their capabilities in the field of climate modeling, where these measures facilitate a spatially explicit model evaluation.Building on a recent study by Feldhoff et al. [8] we comparatively analyze statistical and dynamical regional climate simulations of the South American monsoon system [corrected]. types of climate networks representing different aspects of rainfall dynamics are constructed from the modeled precipitation space-time series. Specifically, we define simple graphs based on positive as well as negative rank correlations between rainfall anomaly time series at different locations, and such based on spatial synchronizations of extreme rain events. An evaluation against respective networks built from daily satellite data provided by the Tropical Rainfall Measuring Mission 3B42 V7 reveals far greater differences in model performance between network types for a fixed but arbitrary climate model than between climate models for a fixed but arbitrary network type. We identify two sources of uncertainty in this respect. Firstly, climate variability limits fidelity, particularly in the case of the extreme event network; and secondly, larger geographical link lengths render link misplacements more likely, most notably in the case of the anticorrelation network; both contributions are quantified using suitable ensembles of surrogate networks. Our model evaluation approach is applicable to any multidimensional dynamical system and especially our simple graph difference measures are highly versatile as the graphs to be compared may be constructed in whatever way required. Generalizations to directed as well as edge- and node

  13. Impulsivity moderates the relationship between previous quit failure and cue-induced craving.

    Science.gov (United States)

    Erblich, Joel; Michalowski, Alexandra

    2015-12-01

    Poor inhibitory control has been shown to be an important predictor of relapse to a number of drugs, including nicotine. Indeed, smokers who exhibit higher levels of impulsivity are thought to have impaired regulation of urges to smoke, and previous research has suggested that impulsivity may moderate cue-induced cigarette cravings. To that end, we conducted a study to evaluate the interplay between failed smoking cessation, cue-induced craving, and impulsivity. Current smokers (n=151) rated their cigarette cravings before and after laboratory to exposure to smoking cues, and completed questionnaires assessing impulsivity and previous failed quit attempts. Findings indicated that shorter duration of previous failed quit attempts was related to higher cue-induced cigarette craving, especially among smokers with higher levels of impulsivity. Results underscore the importance of considering trait impulsivity as a factor in better understanding the management of cue-induced cravings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Evaluation of uncertainty in the measurement of environmental electromagnetic fields

    International Nuclear Information System (INIS)

    Vulevic, B.; Osmokrovic, P.

    2010-01-01

    With regard to Non-ionising radiation protection, the relationship between human exposure to electromagnetic fields and health is controversial. Electromagnetic fields have become omnipresent in the daily environment. This paper assesses the problem of how to compare a measurement result with a limit fixed by the standard for human exposure to electric, magnetic and electromagnetic fields (0 Hz-300 GHz). The purpose of the paper is an appropriate representation of the basic information about evaluation of measurement uncertainty. (authors)

  15. A strategy for evaluating pathway analysis methods.

    Science.gov (United States)

    Yu, Chenggang; Woo, Hyung Jun; Yu, Xueping; Oyama, Tatsuya; Wallqvist, Anders; Reifman, Jaques

    2017-10-13

    Researchers have previously developed a multitude of methods designed to identify biological pathways associated with specific clinical or experimental conditions of interest, with the aim of facilitating biological interpretation of high-throughput data. Before practically applying such pathway analysis (PA) methods, we must first evaluate their performance and reliability, using datasets where the pathways perturbed by the conditions of interest have been well characterized in advance. However, such 'ground truths' (or gold standards) are often unavailable. Furthermore, previous evaluation strategies that have focused on defining 'true answers' are unable to systematically and objectively assess PA methods under a wide range of conditions. In this work, we propose a novel strategy for evaluating PA methods independently of any gold standard, either established or assumed. The strategy involves the use of two mutually complementary metrics, recall and discrimination. Recall measures the consistency of the perturbed pathways identified by applying a particular analysis method to an original large dataset and those identified by the same method to a sub-dataset of the original dataset. In contrast, discrimination measures specificity-the degree to which the perturbed pathways identified by a particular method to a dataset from one experiment differ from those identifying by the same method to a dataset from a different experiment. We used these metrics and 24 datasets to evaluate six widely used PA methods. The results highlighted the common challenge in reliably identifying significant pathways from small datasets. Importantly, we confirmed the effectiveness of our proposed dual-metric strategy by showing that previous comparative studies corroborate the performance evaluations of the six methods obtained by our strategy. Unlike any previously proposed strategy for evaluating the performance of PA methods, our dual-metric strategy does not rely on any ground truth

  16. Performance Evaluation of Thermographic Cameras for Photogrammetric Measurements

    Science.gov (United States)

    Yastikli, N.; Guler, E.

    2013-05-01

    The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was modelled efficiently

  17. Biases in cost measurement for economic evaluation studies in health care.

    Science.gov (United States)

    Jacobs, P; Baladi, J F

    1996-01-01

    This paper addresses the issue of biases in cost measures which used in economic evaluation studies. The basic measure of hospital costs which is used by most investigators is unit cost. Focusing on this measure, a set of criteria which the basic measures must fulfil in order to approximate the marginal cost (MC) of a service for the relevant product, in the representative site, was identified. Then four distinct biases--a scale bias, a case mix bias, a methods bias and a site selection bias--each of which reflects the divergence of the unit cost measure from the desired MC measure, were identified. Measures are proposed for several of these biases and it is suggested how they can be corrected.

  18. Measurement and evaluation of alpha radioactivity using ionized air transport technology

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Yamaguchi, Hiromi

    2009-01-01

    A novel alpha radioactivity monitor using ionized air transport technology has been developed for future constitution of 'clearance level' for uranium and TRU radioactive waste. This technology will bring paradigm shift on alpha-ray measurement, such as converting 'closely contacting and scanning measurement' to 'remotely contacting measurement in the block', and drastically improve the efficiency of measurement operation. In this article, the origin and chronicle of this technology were simply explained and our newest accomplishment was described. Furthermore, using measurement data obtained in our development process, measurement and evaluation examples of alpha radioactivity were shown for practical operations as informative guides. We hope that this technology will be widely endorsed as a practical method for alpha clearance measurement in the near future. (author)

  19. Evaluation of thyroid radioactivity measurement data from Hanford workers, 1944--1946

    Energy Technology Data Exchange (ETDEWEB)

    Ikenberry, T.A.

    1991-05-01

    This report describes the preliminary results of an evaluation conducted in support of the Hanford Environmental Dose Reconstruction (HEDR) Project. The primary objective of the HEDR Project is to estimate the radiation doses that populations could have received from nuclear operations at the Hanford Site since 1944. A secondary objective is to make information that HEDR staff members used in estimate radiation doses available to the public. The objectives of this report to make available thyroid measurement data from Hanford workers for the year 1944 through 1946, and to investigate the suitability of those data for use in the HEDR dose estimation process. An important part of this investigation was to provide a description of the uncertainty associated with the data. Lack of documentation on thyroid measurements from this period required that assumptions be made to perform data evaluations. These assumptions introduce uncertainty into the evaluations that could be significant. It is important to recognize the nature of these assumptions, the inherent uncertainty, and the propagation of this uncertainty, and the propagation of this uncertainty through data evaluations to any conclusions that can be made by using the data. 15 refs., 1 fig., 5 tabs.

  20. A Comparison of Several Outcome Measures Used to Evaluate a Psychiatric Clerkship.

    Science.gov (United States)

    Cuerdon, Timothy; And Others

    The teaching of interviewing skills is increasingly incorporated into clinical medicine courses in American medical schools, yet the attempts to evaluate the effectiveness of these efforts have been woefully inadequate. Typical outcome measures have included paper and pencil tests of knowledge, preceptor evaluations of clinical performance, and…

  1. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

    International Nuclear Information System (INIS)

    Fu Tairan; Cheng Xiaofang; Yang Zangjian

    2008-01-01

    We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution

  2. [Effects of mere exposure on category evaluation measured by the IAT and the GNAT].

    Science.gov (United States)

    Kawakami, Naoaki; Sato, Hirotsune; Yoshida, Fujio

    2010-12-01

    Based on mere exposure studies, we proposed that repeated exposure to stimuli belonging to a common category leads to a positive evaluation of that category. Furthermore, to investigate the implicit effects of mere exposure, indirect measures were used. In a series of experiments, participants were repeatedly exposed to mimetic words written in Japanese hiragana or katakana, or nothing (control). Then their evaluations of the category ("hiragana" or "katakana") were measured using indirect and direct measures. In Experiment 1 (Implicit Association Test; IAT), we adopted a traditional design using an exposure paradigm, such that the rating stimuli were identical to the exposed stimuli. Significant effects were observed for both measures. In Experiment 2 (IAT) and Experiment 3 (Go/No-go Association Task; GNAT), we used non-exposed stimuli that belonged to a common category as the rating stimuli. Significant effects were observed only for indirect measures. These results indicate that repeated exposure has unconscious positive effects on category evaluation. Theoretical and methodological implications of the findings are discussed.

  3. An evaluated neutronic data file for elemental zirconium

    International Nuclear Information System (INIS)

    Smith, A.B.; Chiba, S.

    1994-09-01

    A comprehensive evaluated neutronic data file for elemental zirconium is derived and presented in the ENDF/B-VI formats. The derivation is based upon measured microscopic nuclear data, augmented by model calculations as necessary. The primary objective is a quality contemporary file suitable for fission-reactor development extending from conventional thermal to fast and innovative systems. This new file is a significant improvement over previously available evaluated zirconium files, in part, as a consequence of extensive new experimental measurements reported elsewhere

  4. Comparison of ISO-GUM and Monte Carlo Method for Evaluation of Measurement Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Young-Cheol; Her, Jae-Young; Lee, Seung-Jun; Lee, Kang-Jin [Korea Gas Corporation, Daegu (Korea, Republic of)

    2014-07-15

    To supplement the ISO-GUM method for the evaluation of measurement uncertainty, a simulation program using the Monte Carlo method (MCM) was developed, and the MCM and GUM methods were compared. The results are as follows: (1) Even under a non-normal probability distribution of the measurement, MCM provides an accurate coverage interval; (2) Even if a probability distribution that emerged from combining a few non-normal distributions looks as normal, there are cases in which the actual distribution is not normal and the non-normality can be determined by the probability distribution of the combined variance; and (3) If type-A standard uncertainties are involved in the evaluation of measurement uncertainty, GUM generally offers an under-valued coverage interval. However, this problem can be solved by the Bayesian evaluation of type-A standard uncertainty. In this case, the effective degree of freedom for the combined variance is not required in the evaluation of expanded uncertainty, and the appropriate coverage factor for 95% level of confidence was determined to be 1.96.

  5. Evaluation of indices for voltage stability monitoring using PMU measurements

    Directory of Open Access Journals (Sweden)

    Sindy Lorena Ramirez Perdomo

    2014-09-01

    Full Text Available Large disturbances such as voltage collapse and its consequences represent a large challenge to the operational safety of power systems. Therefore, it is important to have indicators of the presence of voltage stability problems in real time. Using phasor measure-ments of voltage and current that are presented in Phasor Measurement Units (PMU, indices for voltage stability monitoring can be calculated in real time. This paper presents some indices for voltage stability monitoring using PMU measurements. Evaluation of such indices on a simplified system was carried out, and the indices were classified according to their method of calculation. Finally, one of these indices was used with the New England 39-bus system under different operating scenarios, including load increments, line output and generator output, to check the indices’ behavior for voltage stability monitoring based on synchronized local measurements.

  6. Evaluation of a MTT assay in measurement of radiosensitizing effect

    International Nuclear Information System (INIS)

    Higuchi, Keiko; Mitsuhashi, Norio; Saitoh, Jun-ichi; Maebayashi, Katsuya; Sakurai, Hideyuki; Akimoto, Tetsuo; Niibe, Hideo

    1999-01-01

    The usefulness of a MTT assay by measuring the radiosensitizing effect of caffeine on rat yolk sac tumor cell line with a mutant-type p53 in vitro was evaluated. A rat yolk sac tumor cell line with a mutant-type p53, NMT-1R, was used in this study. The radiosensitivity of NMT-1R with or without caffeine was measured with a MTT assay. The results were compared with those by a clonogenic assay. Caffeine at a concentration of 2.0 mM which released radiation-induced G 2 block demonstrated a radiosensitizing effect, but caffeine at a concentration of 0.5 mM did not. The radiosensitizing effect of caffeine measured by a MTT assay correlated with that measured by a clonogenic assay. A MTT assay was useful to measure radiosensitivity and/or a radiosensitizing effect in vitro. (author)

  7. Using the lambda function to evaluate probe measurements of charged dielectric surfaces

    DEFF Research Database (Denmark)

    Rerup, T. O.; Crichton, George C; McAllister, Iain Wilson

    1996-01-01

    The use of Pedersen's λ function to evaluate electrostatic probe measurements of charged dielectric surfaces is demonstrated. With a knowledge of the probe λ function, the procedure by which this function is employed is developed, and thereafter applied to a set of experimental measurements avail...

  8. Components of Standing Postural Control Evaluated in Pediatric Balance Measures: A Scoping Review.

    Science.gov (United States)

    Sibley, Kathryn M; Beauchamp, Marla K; Van Ooteghem, Karen; Paterson, Marie; Wittmeier, Kristy D

    2017-10-01

    To identify measures of standing balance validated in pediatric populations, and to determine the components of postural control captured in each tool. Electronic searches of MEDLINE, Embase, and CINAHL databases using key word combinations of postural balance/equilibrium, psychometrics/reproducibility of results/predictive value of tests, and child/pediatrics; gray literature; and hand searches. Inclusion criteria were measures with a stated objective to assess balance, with pediatric (≤18y) populations, with at least 1 psychometric evaluation, with at least 1 standing task, with a standardized protocol and evaluation criteria, and published in English. Two reviewers independently identified studies for inclusion. There were 21 measures included. Two reviewers extracted descriptive characteristics, and 2 investigators independently coded components of balance in each measure using a systems perspective for postural control, an established framework for balance in pediatric populations. Components of balance evaluated in measures were underlying motor systems (100% of measures), anticipatory postural control (72%), static stability (62%), sensory integration (52%), dynamic stability (48%), functional stability limits (24%), cognitive influences (24%), verticality (9%), and reactive postural control (0%). Assessing children's balance with valid and comprehensive measures is important for ensuring development of safe mobility and independence with functional tasks. Balance measures validated in pediatric populations to date do not comprehensively assess standing postural control and omit some key components for safe mobility and independence. Existing balance measures, that have been validated in adult populations and address some of the existing gaps in pediatric measures, warrant consideration for validation in children. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. In-vitro accuracy and reproducibility evaluation of probing depth measurements of selected periodontal probes

    Directory of Open Access Journals (Sweden)

    K.N. Al Shayeb

    2014-01-01

    Conclusion: Depth measurements with the Chapple UB-CF-15 probe were more accurate and reproducible compared to measurements with the Vivacare TPS and Williams 14 W probes. This in vitro model may be useful for intra-examiner calibration or clinician training prior to the clinical evaluation of patients or in longitudinal studies involving periodontal evaluation.

  10. Prospective memory and its correlates and predictors in schizophrenia: an extension of previous findings.

    Science.gov (United States)

    Ungvari, Gabor S; Xiang, Yu-Tao; Tang, Wai-Kwong; Shum, David

    2008-09-01

    Prospective memory (PM) is the ability to remember to do something in the future without explicit prompts. Extending the number of subjects and the scope of our previously published study, this investigation examined the relationship between PM and socio-demographic and clinical factors, activities of daily living (ADL) and frontal lobe functions in patients with chronic schizophrenia. One hundred and ten Chinese schizophrenia patients, 60 from the previous study and 50 additional patients recruited for this study, and 110 matched healthy comparison subjects (HC) formed the study sample. Patients' clinical condition and activity of daily living were evaluated with the Brief Psychiatric Rating Scale (BPRS) and the Functional Needs Assessment (FNA). Time- and event-based PM tasks and three tests of prefrontal lobe functions (Design Fluency Test [DFT], Tower of London [TOL], Wisconsin Card Sorting Test [WCST]) were also administered. Patients' level of ADL and psychopathology were not associated with PM functions and only anticholinergic medications (ACM) showed a significant negative correlational relationship with PM tasks. Confirming the findings of the previous study, patients performed significantly more poorly on all two PM tasks than HC. Performance on time-based PM task significantly correlated with age, education level and DFT in HC and with age, DFT, TOL and WCST in patients. Patients' performance on the event-based PM correlated with DFT and one measure of WCST. In patients, TOL and age predicted the performance on time-based PM task; DFT and WCST predicted the event-based task. Involving a large sample of patients with matched controls, this study confirmed that PM is impaired in chronic schizophrenia. Deficient PM functions were related to prefrontal lobe dysfunction in both HC and patients but not to the patients' clinical condition, nor did they significantly affect ADL. ACMs determined certain aspects of PM.

  11. Determining the Measurement Quality of a Montessori High School Teacher Evaluation Survey

    Directory of Open Access Journals (Sweden)

    Anthony Philip Setari

    2017-05-01

    Full Text Available The purpose of this study was to conduct a psychometric validation of a course evaluation instrument, known as a student evaluation of teaching (SET, implemented in a Montessori high school. The authors demonstrate to the Montessori community how to rigorously examine the measurement and assessment quality of instruments used within Montessori schools. The Montessori high school community needs an SET that has been rigorously examined for measurement issues. The examined SET was developed by a Montessori high school, and the sample data were collected from Montessori high school students. Using a Rasch partial credit model, the results of the analysis identified several measurement issues, including multidimensionality, misfit items, and inappropriate item difficulty levels. A revised version of the SET underwent the same analysis procedure, and the results indicated that measurement issues persisted. The authors suggest several ways to improve the overall measurement quality of the instrument while keeping the Montessori foundation. Additional validation studies with a revised version of the SET will be needed before the instrument can be endorsed for full implementation in a Montessori setting.

  12. EVALUATION AND MEASUREMENT OF HAND-TRANSMITTED VIBRATIONS

    Directory of Open Access Journals (Sweden)

    Iveta MARKOVÁ

    2017-12-01

    Full Text Available The goal of this work is the effect of vibrations on selected professionals through questionnaire survey and implementation of experimental vibration measurements on a hand of employee. The observation of vibration effects was chosen in a company, where products are being shaped with pneumatic instruments and there is a risk of an exposure of vibrations on the employees. In experimental part are described and evaluated questionnaire surveys conducted on selected risk factors. The reason is the realization of work with vibrating tools for a longer time, where some parts do wear-out and therefore there is a higher exposure to oscillation.

  13. Effect of media composition, including gelling agents, on isolation of previously uncultured rumen bacteria.

    Science.gov (United States)

    Nyonyo, T; Shinkai, T; Tajima, A; Mitsumori, M

    2013-01-01

    The aim of this study was to develop novel anaerobic media using gellan gum for the isolation of previously uncultured rumen bacteria. Four anaerobic media, a basal liquid medium (BM) with agar (A-BM), a modified BM (MBM) with agar (A-MBM), an MBM with phytagel (P-MBM) and an MBM with gelrite (G-MBM) were used for the isolation of rumen bacteria and evaluated for the growth of previously uncultured rumen bacteria. Of the 214 isolates composed of 144 OTUs, 103 isolates (83 OTUs) were previously uncultured rumen bacteria. Most of the previously uncultured strains were obtained from A-MBM, G-MBM and P-MBM, but the predominant cultural members, isolated from each medium, differed. A-MBM and G-MBM showed significantly higher numbers of different OTUs derived from isolates than A-BM (P rumen bacteria were isolated from all media used, the ratio of previously uncultured bacteria to total isolates was increased in A-MBM, P-MBM and G-MBM. © 2012 The Society for Applied Microbiology.

  14. A method for evaluating the effectiveness of site characterization measurements

    International Nuclear Information System (INIS)

    Ditmars, J.D.

    1987-01-01

    A quantitative approach for evaluating the effectiveness of site characterization measurement activities is developed and illustrated with an example application to hypothetical measurement schemes at a potential geologic repository site for radioactive waste. The method is a general one and could also be applied at sites for underground disposal of hazardous chemicals. The approach presumes that measurements will be undertaken to support predictions of the performance of some aspect of a constructed facility or natural system. It requires a quantitative performance objective, such as groundwater travel time or contaminant concentration, against which to compare predictions of performance. The approach recognizes that such predictions are uncertain because the measurements upon which they are based are uncertain. The effectiveness of measurement activities is quantified by a confidence index, β, that reflects the number of standard deviations separating the best estimate of performance from the predetermined performance objective. Measurements that reduce the uncertainty in predictions lead to increased values of β. 5 refs., 4 figs

  15. Maximum respiratory pressure measuring system : calibration and evaluation of uncertainty

    NARCIS (Netherlands)

    Ferreira, J.L.; Pereira, N.C.; Oliveira Júnior, M.; Vasconcelos, F.H.; Parreira, V.F.; Tierra-Criollo, C.J.

    2010-01-01

    The objective of this paper is to present a methodology for the evaluation of uncertainties in the measurements results obtained during the calibration of a digital manovacuometer prototype (DM) with a load cell sensor pressure device incorporated. Calibration curves were obtained for both pressure

  16. Postural Stability Evaluation of Patients Undergoing Vestibular Schwannoma Microsurgery Employing the Inertial Measurement Unit

    Directory of Open Access Journals (Sweden)

    Patrik Kutilek

    2018-01-01

    Full Text Available The article focuses on a noninvasive method and system of quantifying postural stability of patients undergoing vestibular schwannoma microsurgery. Recent alternatives quantifying human postural stability are rather limited. The major drawback is that the posturography system can evaluate only two physical quantities of body movement and can be measured only on a transverse plane. A complex movement pattern can be, however, described more precisely while using three physical quantities of 3-D movement. This is the reason why an inertial measurement unit (Xsens MTx unit, through which we obtained 3-D data (three Euler angles or three orthogonal accelerations, was placed on the patient’s trunk. Having employed this novel method based on the volume of irregular polyhedron of 3-D body movement during quiet standing, it was possible to evaluate postural stability. To identify and evaluate pathological balance control of patients undergoing vestibular schwannoma microsurgery, it was necessary to calculate the volume polyhedron using the 3-D Leibniz method and to plot three variables against each other. For the needs of this study, measurements and statistical analysis were made on nine patients. The results obtained by the inertial measurement unit showed no evidence of improvement in postural stability shortly after surgery (4 days. The results were consistent with the results obtained by the posturography system. The evaluated translation variables (acceleration and rotary variables (angles measured by the inertial measurement unit correlate strongly with the results of the posturography system. The proposed method and application of the inertial measurement unit for the purpose of measuring patients with vestibular schwannoma appear to be suitable for medical practice. Moreover, the inertial measurement unit is portable and, when compared to other traditional posturography systems, economically affordable. Inertial measurement units can

  17. Review of Micro/Nano Nondestructive Evaluation Technique (II): Measurement of Acoustic Properties

    International Nuclear Information System (INIS)

    Kim, Chung Seok; Park, Ik Keun

    2012-01-01

    The present paper reviews the micro and nano nondestructive evaluation(NDE) technique that is possible to investigate the surface and measure the acoustic properties. The technical theory, features and applications of the ultrasonic atomic force microscopy(UAFM) and scanning acoustic microscopy(SAM) are illustrated. Especially, these technologies are possible to evaluate the mechanical properties in micro/nano structure and surface through the measurement of acoustic properties in addition to the observation of surface and subsurface. Consequently, it is thought that technique developments and applications of these micro/nano NDE in advanced industrial parts together with present nondestructive industry are widely possible hereafter.

  18. Measurement and evaluation of energy efficiency programs: California and South Korea

    International Nuclear Information System (INIS)

    Vine, E.; Rhee, C.H.; Lee, K.D.

    2006-01-01

    One of the key challenges for countries facing electric utility restructuring is to ensure that key public goods, such as energy efficiency programs, do not lose support but are maintained and enhanced via regulatory policy and government action. Moreover, an infrastructure and process also needs to be designed and implemented for conducting the measurement and evaluation of energy efficiency programs. This paper describes the experiences of California and the Republic of Korea (Korea) in addressing these issues. These case studies confirm that the active involvement of regulatory bodies is needed to ensure that energy efficiency investments continue. The case studies also show that the development of an infrastructure and process for conducting rigorous measurement and evaluation takes time and needs the active participation of many stakeholders

  19. Determining the Measurement Quality of a Montessori High School Teacher Evaluation Survey

    Science.gov (United States)

    Setari, Anthony Philip; Bradley, Kelly D.

    2017-01-01

    The purpose of this study was to conduct a psychometric validation of a course evaluation instrument, known as a student evaluation of teaching (SET), implemented in a Montessori high school. The authors demonstrate to the Montessori community how to rigorously examine the measurement and assessment quality of instruments used within Montessori…

  20. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D.; Äystö, J.; Beck, D.; Blaum, K.; Bollen, G.; Herfurth, F.; Jokinen, A.; Kellerbauer, A.; Kluge, H.-J.; Kolhinen, V.S.; Oinonen, M.; Sauvan, E.; Schwarz, S.

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  1. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  2. Scanners for analytic print measurement: the devil in the details

    Science.gov (United States)

    Zeise, Eric K.; Williams, Don; Burns, Peter D.; Kress, William C.

    2007-01-01

    Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address characteristics of flatbed reflection scanners in the evaluation of print uniformity, geometric distortion, geometric repeatability and the influence of scanner MTF and noise on analytic measurements. Suggestions are made for the specification and evaluation of scanners to be used in print image quality standards that are being developed.

  3. Alpha radioactivity measurement technology with ionized air type measurement. Applicability evaluation to verification of the clearance level

    International Nuclear Information System (INIS)

    Mita, Yutaka; Matsumura, Toshihiro; Yokoyama, Kaoru; Sugitsue, Noritake

    2008-10-01

    The purpose of this test is to evaluate the applicability of the clearance level measuring system by Ionized Air Type Measurement after decontaminated by sulfuric acid sample. In Ningyo-toge Environmental Engineering Center. The equipment and radioactive waste which were contaminated with uranium are generated so much in future dismantling stage. In our plan, some of equipments and radioactive waste are contaminated to a clearance level, and cut down on decommission and disposal expense. This plan needs the alpha-rays measurement technology of the very low level. We think that ionized Air transfer measurement technology is promising as of clearance verification technology. The ionized Air transfer measurement technology applied to the Ionized Air Type Measurement can measure plan radioactivity of a very low level. Moreover, as compared with a direct survey, there is the merit which can be measured in a short time. However ionized Air transfer measurement technology is new technology. Therefore, there is almost no measurement track record. Furthermore, the date about the influence of a background, a detection limit, measurement performance, and reliability is insufficient. So, this measurement test estimated applicability as clearance level verification of an Ionized Air Type Measurement. (author)

  4. Books average previous decade of economic misery.

    Science.gov (United States)

    Bentley, R Alexander; Acerbi, Alberto; Ormerod, Paul; Lampos, Vasileios

    2014-01-01

    For the 20(th) century since the Depression, we find a strong correlation between a 'literary misery index' derived from English language books and a moving average of the previous decade of the annual U.S. economic misery index, which is the sum of inflation and unemployment rates. We find a peak in the goodness of fit at 11 years for the moving average. The fit between the two misery indices holds when using different techniques to measure the literary misery index, and this fit is significantly better than other possible correlations with different emotion indices. To check the robustness of the results, we also analysed books written in German language and obtained very similar correlations with the German economic misery index. The results suggest that millions of books published every year average the authors' shared economic experiences over the past decade.

  5. Effectiveness of transmitting safety-measures information in risk communication of nuclear power generation. Evaluation by the receiver of the messages

    International Nuclear Information System (INIS)

    Matsumoto, Takanobu; Shiomi, Tetsuro

    2004-01-01

    Effectiveness of risk communication were previously discussed through both ''risk information'' and ''benefit information'' of its topics. However, in technical facilities facilities such as nuclear power plant where safeness is an important concern, not only these two aspects but also safety-measures information'' are required. There have been previously no such discussions about risk communication that included ''safety-measures information''. In this report, we investigated general public's view of the difference in effectiveness of risk communication between two cases. In the first case, only ''risk'' and ''benefit information'' were given. In the second case, we added ''safety-measures information'' as well as ''risk'' and benefit information''. Measurement of the effect was performed using a questionnaire. We divided the subjects into two groups. Each group was shown one side of two pamphlets which had information concerning two conditions, and asked how it feels about ''reliance on information'', ''reliance on informer'', ''posture considered with informer'' which are factors in the process of the attitude change that is shown in the paradigm of risk communication (Kinoshita and Kikkawa, (1990)). Prior to this investigation, we identified each subject is position on nuclear power generation. Thus we were able to clarify the effectiveness of each risk communication style depending on each subject is position (approval, neutrality, objection). As a result, we reached the following conclusions: First about ''reliance on information'', where asked whether the contents of a pamphlet would be reliable, it was found that the person negative to nuclear power generation evaluated lower the pamphlet which included ''safety-measures information'' than the other. However, it was found that regardless of the difference in the position towards nuclear power generation, people who read the pamphlet including ''safety-measures information'' evaluated higher ''reliance on

  6. Evaluation of body condition score measured throughout lactation as an indicator of fertility in dairy cattle.

    Science.gov (United States)

    Banos, G; Brotherstone, S; Coffey, M P

    2004-08-01

    Body condition score (BCS) records of primiparous Holstein cows were analyzed both as a single measure per animal and as repeated measures per sire of cow. The former resulted in a single, average, genetic evaluation for each sire, and the latter resulted in separate genetic evaluations per day of lactation. Repeated measure analysis yielded genetic correlations of less than unity between days of lactation, suggesting that BCS may not be the same trait across lactation. Differences between daily genetic evaluations on d 10 or 30 and subsequent daily evaluations were used to assess BCS change at different stages of lactation. Genetic evaluations for BCS level or change were used to estimate genetic correlations between BCS measures and fertility traits in order to assess the capacity of BCS to predict fertility. Genetic correlation estimates with calving interval and non-return rate were consistently higher for daily BCS than single measure BCS evaluations, but results were not always statistically different. Genetic correlations between BCS change and fertility traits were not significantly different from zero. The product of the accuracy of BCS evaluations with their genetic correlation with the UK fertility index, comprising calving interval and non-return rate, was consistently higher for daily than for single BCS evaluations, by 28 to 53%. This product is associated with the conceptual correlated response in fertility from BCS selection and was highest for early (d 10 to 75) evaluations.

  7. Improving pilot mental workload evaluation with combined measures.

    Science.gov (United States)

    Wanyan, Xiaoru; Zhuang, Damin; Zhang, Huan

    2014-01-01

    Behavioral performance, subjective assessment based on NASA Task Load Index (NASA-TLX), as well as physiological measures indexed by electrocardiograph (ECG), event-related potential (ERP), and eye tracking data were used to assess the mental workload (MW) related to flight tasks. Flight simulation tasks were carried out by 12 healthy participants under different MW conditions. The MW conditions were manipulated by setting the quantity of flight indicators presented on the head-up display (HUD) in the cruise phase. In this experiment, the behavioral performance and NASA-TLX could reflect the changes of MW ideally. For physiological measures, the indices of heart rate variability (HRV), P3a, pupil diameter and eyelid opening were verified to be sensitive to MW changes. Our findings can be applied to the comprehensive evaluation of MW during flight tasks and the further quantitative classification.

  8. Sensitivity evaluation of dynamic speckle activity measurements using clustering methods

    International Nuclear Information System (INIS)

    Etchepareborda, Pablo; Federico, Alejandro; Kaufmann, Guillermo H.

    2010-01-01

    We evaluate and compare the use of competitive neural networks, self-organizing maps, the expectation-maximization algorithm, K-means, and fuzzy C-means techniques as partitional clustering methods, when the sensitivity of the activity measurement of dynamic speckle images needs to be improved. The temporal history of the acquired intensity generated by each pixel is analyzed in a wavelet decomposition framework, and it is shown that the mean energy of its corresponding wavelet coefficients provides a suited feature space for clustering purposes. The sensitivity obtained by using the evaluated clustering techniques is also compared with the well-known methods of Konishi-Fujii, weighted generalized differences, and wavelet entropy. The performance of the partitional clustering approach is evaluated using simulated dynamic speckle patterns and also experimental data.

  9. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    Science.gov (United States)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  10. Measuring and evaluating morphological asymmetry in fish: distinct lateral dimorphism in the jaws of scale-eating cichlids.

    Science.gov (United States)

    Hata, Hiroki; Yasugi, Masaki; Takeuchi, Yuichi; Takahashi, Satoshi; Hori, Michio

    2013-11-01

    The left-right asymmetry of scale-eating Tanganyikan cichlids is described as a unilateral topographical shift of the quadratomandibular joints. This morphological laterality has a genetic basis and has therefore been used as a model for studying negative frequency-dependent selection and the resulting oscillation in frequencies of two genotypes, lefty and righty, in a population. This study aims were to confirm this laterality in Perissodus microlepis Boulenger and P. straeleni (Poll) and evaluate an appropriate method for measuring and testing the asymmetry. Left-right differences in the height of the mandible posterior ends (HMPE) and the angle between the neurocranium and vertebrae of P. microlepis and P. straeleni were measured on skeletal specimens. Snout-bending angle was also measured using a dorsal image of the same individuals following a previous method. To define which distribution model, fluctuating asymmetry (FA), directional asymmetry (DA), or antisymmetry (AS), best fit to the lateral asymmetry of the traits, we provided an R package, IASD. As a result, HMPE and neurocranium-vertebrae angle of both species were best fitted to AS, suggesting that P. microlepis and P. straeleni showed a distinct dimorphism in these traits, although snout-bending angle of P. microlepis was best fitted to FA. Measurement error was low for HMPE comparing the snout-bending angle in P. microlepis, indicating that measuring HMPE is a more accurate method. The scale-eating tribe Perissodini showed distinct antisymmetry in the jaw skeleton and neurocranium-vertebrae angle, and this laterality remains a valid marker for further evolutionary studies.

  11. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  12. Outcome measures for oral health based on clinical assessments and claims data: feasibility evaluation in practice.

    Science.gov (United States)

    Hummel, Riët; Bruers, Josef; van der Galiën, Onno; van der Sanden, Wil; van der Heijden, Geert

    2017-10-05

    It is well known that treatment variation exists in oral healthcare, but the consequences for oral health are unknown as the development of outcome measures is still in its infancy. The aim of this study was to identify and develop outcome measures for oral health and explore their performance using health insurance claims records and clinical data from general dental practices. The Dutch healthcare insurance company Achmea collaborated with researchers, oral health experts, and general dental practitioners (GDPs) in a proof of practice study to test the feasibility of measures in general dental practices. A literature search identified previously described outcome measures for oral healthcare. Using a structured approach, identified measures were (i) prioritized, adjusted and added to after discussion and then (ii) tested for feasibility of data collection, their face validity and discriminative validity. Data sources were claims records from Achmea, clinical records from dental practices, and prospective, pre-determined clinical assessment data obtained during routine consultations. In total eight measures (four on dental caries, one on tooth wear, two on periodontal health, one on retreatment) were identified, prioritized and tested. The retreatment measure and three measures for dental caries were found promising as data collection was feasible, they had face validity and discriminative validity. Deployment of these measures demonstrated variation in clinical practices of GDPs. Feedback of this data to GDPs led to vivid discussions on best practices and quality of care. The measure 'tooth wear' was not considered sufficiently responsive; 'changes in periodontal health score' was considered a controversial measure. The available data for the measures 'percentage of 18-year-olds with no tooth decay' and 'improvement in gingival bleeding index at reassessment' was too limited to provide accurate estimates per dental practice. The evaluated measures 'time to first

  13. An Application of the Impact Evaluation Process for Designing a Performance Measurement and Evaluation Framework in K-12 Environments

    Science.gov (United States)

    Guerra-Lopez, Ingrid; Toker, Sacip

    2012-01-01

    This article illustrates the application of the Impact Evaluation Process for the design of a performance measurement and evaluation framework for an urban high school. One of the key aims of this framework is to enhance decision-making by providing timely feedback about the effectiveness of various performance improvement interventions. The…

  14. Feasibility of quantitative performance measures for evaluating nuclear power plant operators

    International Nuclear Information System (INIS)

    Carter, R.J.; Connelly, E.M.; Krois, P.A.

    1989-01-01

    A more valid measure of team performance in nuclear power plants is needed. A study is described which was oriented towards evaluating the feasibility of synthesizing performance measures by deriving measures for crews responding to an off-normal event in a full-scope simulator. The thesis was that performance assessment is based on the subjective judgment of training instructors. The procedure used to synthesize the performance measure consisted of: identification of the factors believed to be important to performance assessment, development of example crew performances and ratings on each by instructors, and derivation of the measure by capturing the instructors' assessment rules. A performance measure was derived which explains nearly all of the variance of the instructors' team performance assessments. There is reason to believe that this method of synthesizing measures can be applied to other events. 7 tabs

  15. Patterns of presentation of chronic ischemic heart disease with and without previous myocardial infarction

    International Nuclear Information System (INIS)

    Ahmad, R.; Rabbani, A.; Awan, Z.A.

    2009-01-01

    The prevalence of Ischemic Heart Disease (IHD) is on the rise, from increasing lifespan of population and availability of better medical facilities. We studied chronic IHD cases with and without previous myocardial infarction, in Hazara, NWFP, Pakistan to evaluate left ventricular (LV) dysfunction, wall motion abnormalities and complications of IHD. All patients presenting with history of chest pain in Medical 'C' Unit, Ayub Teaching Hospital, Abbottabad from June 2004 to May 2005 were included in the study. Patients with non-cardiac chest pain were excluded from the study. Cases with congenital and rheumatic heart disease, cardiomyopathies, unstable angina and acute MI were excluded. Patients with IHD with or without myocardial infarction (MI) were studied for left ventricular dysfunction (ejection fraction, left atrial size, E/A ratio), wall motion abnormalities and complications of IHD (Mitral regurgitation, Ventricular Septal Defect (VSD), LV aneurysm, LV clot). Clinical and echocardiographic evaluation was done in each case. Out of 183 cases of chronic IHD, 123 patients were without previous MI and 60 had had previous MI. Ejection fraction (EF) was 45%+-15 in the group without MI and 35+-11% in cases with MI. Left Atrium (LA) size was 35+-6 mm and 39+-4 mm in the two groups respectively. LV diastolic dysfunction was seen in 17% in the first and 24% in the second group respectively. Global hypokinesia was seen in 8% and 17% in the 2 groups respectively. Regional Wall Motion Abnormality (RWMA) was observed in 12% in patients without MI and in 58% cases with MI. Mitral regurgitation was seen in 10 and 20% in the 2 groups respectively LV clots, VSD, LV and aneurysm were seen in 8.4, 5, and 6.5% respectively, only in cases with previous MI. LV dysfunction, wall motion abnormalities and mitral regurgitation were more common in IHD cases with previous heart attack. (author)

  16. Radioactivity measurement in Austria 1992 and 1993. Data and evaluation

    International Nuclear Information System (INIS)

    Bobek, E.

    1995-01-01

    The Federal Ministry of Health and Consumer Protection is responsible for the large scale surveillance of radioactive contaminations of the Austrian territory. For this purpose on one hand an on-line measurement system has been set up, using gamma dose rate measuring devices situated in 336 locations. On the other hand, various media e.g. aerosols, precipitation, surface water and foodstuffs are being collected. Their radionuclide content is analysed in several laboratories. Additional special projects have been set up to improve the knowledge of the time dependence respectively of regional aspects of the contamination situation. The report covers the results of this surveillance for the years 1992 and 1993. The evaluation of these measurements and of other data concerning the average exposure of the Austrian population for the year 1993 is summarized in the following figure. It can be seen that the main contributions to the radiation dose are due to natural exposure pathways, among which the inhalation of indoor radon is of main importance. (Compared to the data in earlier reports due to a new evaluation of the radon risk by ICRP this dose contribution is significantly lower.) In comparison, the component due to the consequences of the Chernobyl reactor accident in 1986 onto Austrian territory during 1992 and 1993 was marginal. (author)

  17. Evaluation and analytical validation of a handheld digital refractometer for urine specific gravity measurement

    Directory of Open Access Journals (Sweden)

    Sara P. Wyness

    2016-08-01

    Full Text Available Objectives: Refractometers are commonly used to determine urine specific gravity (SG in the assessment of hydration status and urine specimen validity testing. Few comprehensive performance evaluations are available demonstrating refractometer capability from a clinical laboratory perspective. The objective of this study was therefore to conduct an analytical validation of a handheld digital refractometer used for human urine SG testing. Design and methods: A MISCO Palm Abbe™ refractometer was used for all experiments, including device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, evaluation of potential substances which contribute to SG (i.e. “interference”, and reference interval evaluation. A manual refractometer, urine osmometer, and a solute score (sum of urine chloride, creatinine, glucose, potassium, sodium, total protein, and urea nitrogen; all in mg/dL were used as comparative methods for accuracy assessment. Results: Significant carryover was not observed. A wash step was still included as good laboratory practice. Low imprecision (%CV, <0.01 was demonstrated using low and high QC material. Accuracy studies showed strong correlation to manual refractometry. Linear correlation was also demonstrated between SG, osmolality, and solute score. Linearity of Palm Abbe performance was verified with observed error of ≤0.1%. Increases in SG were observed with increasing concentrations of albumin, creatinine, glucose, hemoglobin, sodium chloride, and urea. Transference of a previously published urine SG reference interval of 1.0020–1.0300 was validated. Conclusions: The Palm Abbe digital refractometer was a fast, simple, and accurate way to measure urine SG. Analytical validity was confirmed by the present experiments. Keywords: Specific gravity, Osmolality, Digital refractometry, Hydration, Sports medicine, Urine drug testing, Urine adulteration

  18. Development and evaluation of the INSPIRE measure of staff support for personal recovery.

    Science.gov (United States)

    Williams, Julie; Leamy, Mary; Bird, Victoria; Le Boutillier, Clair; Norton, Sam; Pesola, Francesca; Slade, Mike

    2015-05-01

    No individualised standardised measure of staff support for mental health recovery exists. To develop and evaluate a measure of staff support for recovery. initial draft of measure based on systematic review of recovery processes; consultation (n = 61); and piloting (n = 20). Psychometric evaluation: three rounds of data collection from mental health service users (n = 92). INSPIRE has two sub-scales. The 20-item Support sub-scale has convergent validity (0.60) and adequate sensitivity to change. Exploratory factor analysis (variance 71.4-85.1 %, Kaiser-Meyer-Olkin 0.65-0.78) and internal consistency (range 0.82-0.85) indicate each recovery domain is adequately assessed. The 7-item Relationship sub-scale has convergent validity 0.69, test-retest reliability 0.75, internal consistency 0.89, a one-factor solution (variance 70.5 %, KMO 0.84) and adequate sensitivity to change. A 5-item Brief INSPIRE was also evaluated. INSPIRE and Brief INSPIRE demonstrate adequate psychometric properties, and can be recommended for research and clinical use.

  19. Measuring Principals' Effectiveness: Results from New Jersey's First Year of Statewide Principal Evaluation. REL 2016-156

    Science.gov (United States)

    Herrmann, Mariesa; Ross, Christine

    2016-01-01

    States and districts across the country are implementing new principal evaluation systems that include measures of the quality of principals' school leadership practices and measures of student achievement growth. Because these evaluation systems will be used for high-stakes decisions, it is important that the component measures of the evaluation…

  20. Best methods for evaluating educational impact: a comparison of the efficacy of commonly used measures of library instruction.

    Science.gov (United States)

    Schilling, Katherine; Applegate, Rachel

    2012-10-01

    Libraries are increasingly called upon to demonstrate student learning outcomes and the tangible benefits of library educational programs. This study reviewed and compared the efficacy of traditionally used measures for assessing library instruction, examining the benefits and drawbacks of assessment measures and exploring the extent to which knowledge, attitudes, and behaviors actually paralleled demonstrated skill levels. An overview of recent literature on the evaluation of information literacy education addressed these questions: (1) What evaluation measures are commonly used for evaluating library instruction? (2) What are the pros and cons of popular evaluation measures? (3) What are the relationships between measures of skills versus measures of attitudes and behavior? Research outcomes were used to identify relationships between measures of attitudes, behaviors, and skills, which are typically gathered via attitudinal surveys, written skills tests, or graded exercises. Results provide useful information about the efficacy of instructional evaluation methods, including showing significant disparities between attitudes, skills, and information usage behaviors. This information can be used by librarians to implement the most appropriate evaluation methods for measuring important variables that accurately demonstrate students' attitudes, behaviors, or skills.

  1. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  2. Alberta CancerBridges development of a care plan evaluation measure

    Science.gov (United States)

    Giese-Davis, J.; Sisler, J.; Zhong, L.; Brandelli, Y.; McCormick, J.L.; Railton, C.; Shirt, L.; Lau, H.; Hao, D.; Chobanuk, J.; Walley, B.; Joy, A.A.; Taylor, A.; Carlson, L.

    2018-01-01

    Background No standardized measures specifically assess cancer survivors’ and healthcare providers’ experience of Survivor Care Plans (scps). We sought to develop two care plan evaluation (cpe) measures, one for survivors (cpe-s) and one for healthcare providers (cpe-p), examine initial psychometric qualities in Alberta, and assess generalizability in Manitoba, Canada. Methods We developed the initial measures using convenience samples of breast (n = 35) and head and neck (n = 18) survivors who received scps at the end of active cancer-centre treatment. After assessing Alberta’s scp concordance with Institute of Medicine (iom) recommendations using a published coding scheme, we examined psychometric qualities for the cpe-s and cpe-p. We examined generalizability in Manitoba, Canada, with colorectal survivors discharged to primary care providers for follow-up (n = 75). Results We demonstrated acceptable internal consistency for the cpe-s and cpe-p subscales and total score after eliminating one item per subscale for cpe-s, two for cpe-p, resulting in revised scales with four 7-item and 6-item subscales, respectively. Subscale scores correlated highly indicating that for each measure the total score may be the most reliable and valid. We provide initial cpe-s discriminant, convergent, and predictive validity using the total score. Using the Manitoba sample, initial psychometrics similarly indicated good generalizability across differences in tumour groups, scp, and location. Conclusions We recommend the revised cpe-s and cpe-p for further use and development. Studies documenting the creation and standardization of scp evaluations are few, and we recommend further development of patient experience measures to improve both clinical practice and the specificity of research questions. PMID:29507497

  3. A measure to evaluate classroom teaching practices in nursing.

    Science.gov (United States)

    Herinckx, Heidi; Munkvold, Julia Paschall; Winter, Elisabeth; Tanner, Christine A

    2014-01-01

    The Oregon Consortium for Nursing Education (OCNE) Classroom Teaching Fidelity Scale was created to measure the implementation of the OCNE curriculum and its related pedagogy. OCNE is a partnership of eight community colleges and the five-campus state-supported university. OCNE developed a shared competency-based curriculum and pedagogical practices. An essential part of the OCNE evaluation was to measure the extent the curriculum and pedagogical model were implemented on each partner campus. The scale was developed using a multistep methodology, including review of the literature and OCNE guidelines and materials, frequent consultation with local and national advisory boards, and multiple observations of OCNE classrooms over a two-year period. Fidelity scores are reported for 10 OCNE colleges observed in 2009. CONCLUSlON: The creation and use of this fidelity scale and similar measures may contribute to the emerging science of nursing education by more clearly documenting educational reform efforts..

  4. Measurement of Responsibility: A Critical Evaluation of Level of Work Measurement by Time-Span of Discretion.

    Science.gov (United States)

    Laner, S.; And Others

    This report is a critical evaluation based on extended field trials and theoretical analysis of the time-span technique of measuring level of work in organizational hierarchies. It is broadly concluded that the technique does possess many of the desirable features claimed by its originator, but that earlier, less highly structured versions based…

  5. Cosmic-ray neutron simulations and measurements in Taiwan

    International Nuclear Information System (INIS)

    Chen, Wei-Lin; Jiang, Shiang-Huei; Sheu, Rong-Jiun

    2014-01-01

    This study used simulations of galactic cosmic ray in the atmosphere to investigate the neutron background environment in Taiwan, emphasising its altitude dependence and spectrum variation near interfaces. The calculated results were analysed and compared with two measurements. The first measurement was a mobile neutron survey from sea level up to 3275 m in altitude conducted using a car-mounted high-sensitivity neutron detector. The second was a previous measured result focusing on the changes in neutron spectra near air/ground and air/water interfaces. The attenuation length of cosmic-ray neutrons in the lower atmosphere was estimated to be 163 g cm -2 in Taiwan. Cosmic-ray neutron spectra vary with altitude and especially near interfaces. The determined spectra near the air/ground and air/water interfaces agree well with measurements for neutrons below 10 MeV. However, the high-energy portion of spectra was observed to be much higher than our previous estimation. Because high-energy neutrons contribute substantially to a dose evaluation, revising the annual sea-level effective dose from cosmic-ray neutrons at ground level in Taiwan to 35 μSv, which corresponds to a neutron flux of 5.30 x 10 -3 n cm -2 s -1 , was suggested. The cosmic-ray neutron background in Taiwan was studied using the FLUKA simulations and field measurements. A new measurement was performed using a car-mounted high-efficiency neutron detector, re-coding real-time neutron counting rates from sea level up to 3275 m. The attenuation of cosmic-ray neutrons in the lower atmosphere exhibited an effective attenuation length of 163 g cm -2 . The calculated neutron counting rates over predicted the measurements by ∼32 %, which leaded to a correction factor for the FLUKA-calculated cosmic-ray neutrons in the lower atmosphere in Taiwan. In addition, a previous measurement regarding neutron spectrum variation near the air/ground and air/water interfaces was re-evaluated. The results showed that the

  6. Evaluation of physical activity measures used in middle-aged women.

    Science.gov (United States)

    Pettee Gabriel, Kelley; McClain, James J; Lee, Chong D; Swan, Pamela D; Alvar, Brent A; Mitros, Melanie R; Ainsworth, Barbara E

    2009-07-01

    To evaluate the reliability and validity of five commonly used physical activity questionnaires (PAQ) in women aged 45-65 yr with varying physical activity (PA) levels. Data were obtained from the Evaluation of Physical Activity Measures in Middle-aged Women (PAW) Study and included 66 women (aged 52.6 +/- 5.4 yr). PAQ evaluated include Modifiable Activity Questionnaire (past week and past month version), Nurses' Health Study PAQ, Active Australia Survey, and Women's Health Initiative PAQ. Intraclass correlation coefficients (ICC) between administrations of the PAQ were used to assess test-retest reliability. Spearman rank-order correlation coefficients were used to examine the associations of PA and physical fitness data with PAQ summary estimates. Accelerometer-determined median (25th, 75th percentiles) times (min.d) spent in moderate-lifestyle [760-1951 counts (ct)], moderate-walk (1952-5724 ct), vigorous (> or =5725 ct), and combined moderate and vigorous PA (MVPA > or = 1952 ct) during the 35 d of observation were 66.0 (51.2, 81.3), 23.1 (14.1, 34.6), 0.4 (0.0, 2.3), and 24.3 (15.9, 41.6) min, respectively. The PAQ were shown to be reproducible and relatively stable over time (ICC = 0.32 to 0.91) and were associated with total counts per day (ct.d, 0.46 to 0.60, all P PAQ evaluated in this study were shown to be reliable and associated with PA and physical fitness measures. Current findings support the utility of these PAQ for PA assessment in research studies of middle-aged women.

  7. PERFORMANCE EVALUATION OF THERMOGRAPHIC CAMERAS FOR PHOTOGRAMMETRIC MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    N. Yastikli

    2013-05-01

    Full Text Available The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was

  8. The development and evaluation of the DK-20: a knowledge of dementia measure.

    Science.gov (United States)

    Shanahan, Niamh; Orrell, Martin; Schepers, Astrid K; Spector, Aimee

    2013-11-01

    Raising understanding of dementia has become a key focus of international health and social care. An up-to-date, psychometrically sound measure of dementia knowledge that embraces a biopsychosocial perspective is lacking. The aim of this study is to develop and evaluate the psychometric properties of the DK-20, a dementia knowledge questionnaire aimed at unqualified care staff. Domain and item generation followed recommended measure development procedures. A pilot and large-scale study evaluated the psychometric properties of the measure on a sample of 211 care staff and other dementia professionals. The final 20-item measure encompasses items based on biopsychosocial dementia knowledge and care-specific knowledge. Acceptable test-retest reliability, marginal levels of internal consistency, and evidence for face, content, and construct validity were demonstrated. The DK-20 is the first knowledge of dementia measure to be developed specifically for unqualified care staff and has reasonable psychometric properties. It may be used to identify gaps in knowledge, highlighting areas for inclusion in educational interventions.

  9. Validation and evaluation of measuring methods for the 3D documentation of external injuries in the field of forensic medicine.

    Science.gov (United States)

    Buck, Ursula; Buße, Kirsten; Campana, Lorenzo; Schyma, Christian

    2018-03-01

    Three-dimensional (3D) measurement techniques are gaining importance in many areas. The latest developments brought more cost-effective, user-friendly, and faster technologies onto the market. Which 3D techniques are suitable in the field of forensic medicine and what are their advantages and disadvantages? This wide-ranging study evaluated and validated various 3D measurement techniques for the forensic requirements. High-tech methods as well as low-budget systems have been tested and compared in terms of accuracy, ease of use, expenditure of time, mobility, cost, necessary knowhow, and their limitations. Within this study, various commercial measuring systems of the different techniques were tested. Based on the first results, one measuring system was selected for each technique, which appeared to be the most suitable for the forensic application or is already established in forensic medicine. A body of a deceased, a face and an injury of a living person, and a shoe sole were recorded by 11 people with different professions and previous knowledge using the selected systems. The results were assessed and the personal experiences were evaluated using a questionnaire. In addition, precision investigations were carried out using test objects. The study shows that the hand-held scanner and photogrammetry are very suitable for the 3D documentation of forensic medical findings. Their moderate acquisition costs and easy operation could lead to more frequent application in forensic medicine in the future. For special applications, the stripe-light scanner still has its justification due to its high precision, the flexible application area, and the high reliability. The results show that, thanks to the technological advances, the 3D measurement technology will have more and more impact on the routine of the forensic medical examination.

  10. Measurement, calculation and evaluation of photon production cross-sections

    International Nuclear Information System (INIS)

    Kocherov, N.P.

    1990-03-01

    The IAEA Specialists' Meeting on Measurement, Calculation and Evaluation of Photon Production Cross-Sections was held in Smolenice, Czechoslovakia, 5-7 February 1990. The meeting was hosted by the Institute of Physics of the Electro-Physical Research Centre, Slovak Academy of Sciences, Bratislava. This report contains the conclusions and recommendations of this meeting. The papers which the participants have presented at the meeting will be published as an INDC Report. (author)

  11. Quick evaluation of the neutron dose following a criticality accident by measurement of sodium 24 activity

    International Nuclear Information System (INIS)

    Tabardel, R.; Ricourt, A.; Parmentier, N.

    1984-07-01

    In order to quickly sort out the irradiated individuals following a criticality accident, the neutron dose can be evaluated quickly by measuring the sodium-24 activity induced in the human body. The report supplies the information necessary for this evaluation from the response of various detectors of current use in radiation protection. The first part describes the method of evaluation of sodium-24 activity (A) given by the reading (M) of each instrument. The second part describes the method of kerma evaluation from the measured sodium-24 activity. The third part is an experimental application of the method of kerma evaluation from the sodium-24 activity measured in a phantom irradiated in the SILENE reactor flux. The results given by radiation protection instruments are in good agreement with the calculated values for a front exposure and demonstrate the usefulness of measuring the induced sodium-24 activity by radiation protection instruments of current use [fr

  12. Books Average Previous Decade of Economic Misery

    Science.gov (United States)

    Bentley, R. Alexander; Acerbi, Alberto; Ormerod, Paul; Lampos, Vasileios

    2014-01-01

    For the 20th century since the Depression, we find a strong correlation between a ‘literary misery index’ derived from English language books and a moving average of the previous decade of the annual U.S. economic misery index, which is the sum of inflation and unemployment rates. We find a peak in the goodness of fit at 11 years for the moving average. The fit between the two misery indices holds when using different techniques to measure the literary misery index, and this fit is significantly better than other possible correlations with different emotion indices. To check the robustness of the results, we also analysed books written in German language and obtained very similar correlations with the German economic misery index. The results suggest that millions of books published every year average the authors' shared economic experiences over the past decade. PMID:24416159

  13. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  14. Intelligence, previous convictions and interrogative suggestibility: a path analysis of alleged false-confession cases.

    Science.gov (United States)

    Sharrock, R; Gudjonsson, G H

    1993-05-01

    The main purpose of this study was to investigate the relationship between interrogative suggestibility and previous convictions among 108 defendants in criminal trials, using a path analysis technique. It was hypothesized that previous convictions, which may provide defendants with interrogative experiences, would correlate negatively with 'shift' as measured by the Gudjonsson Suggestibility Scale (Gudjonsson, 1984a), after intelligence and memory had been controlled for. The hypothesis was partially confirmed and the theoretical and practical implications of the findings are discussed.

  15. Ultraviolet radiation, measurements and safety evaluations for radiation protection purposes

    International Nuclear Information System (INIS)

    Witew, B.; Fischer, P.G.

    1983-01-01

    In order to evaluate the effects of ultraviolet radiation, one has to study that photobiologically effective radiation which induces a just measurable threshold reaction. For practical radiation protection, one has to determine the permissible duration of exposure at the end of which the threshold reaction is induced. This time limit is derived by means of spectral measurements and determination of radiation intensity. Detrimental photobiological effects can be avoided, and favourable effects optimized, by observing the time limit. Thus these measurements are used to determine the threshold at which the desired effects of ultraviolet radiation will be accompanied by unwanted effects or damage to persons, as for instance in the use of ultraviolet radiation for operating room sterilization, arc welding work, or cosmetic purposes. (orig.) [de

  16. Evaluating digital libraries in the health sector. Part 1: measuring inputs and outputs.

    Science.gov (United States)

    Cullen, Rowena

    2003-12-01

    This is the first part of a two-part paper which explores methods that can be used to evaluate digital libraries in the health sector. In this first part, some approaches to evaluation that have been proposed for mainstream digital information services are examined for their suitability to provide models for the health sector. The paper summarizes some major national and collaborative initiatives to develop measures for digital libraries, and analyses these approaches in terms of their relationship to traditional measures of library performance, which are focused on inputs and outputs, and their relevance to current debates among health information specialists. The second part* looks more specifically at evaluative models based on outcomes, and models being developed in the health sector.

  17. TRIM timber projections: an evaluation based on forest inventory measurements.

    Science.gov (United States)

    John R. Mills

    1989-01-01

    Two consecutive timberland inventories collected from permanent plots in the natural pine type in North Carolina were used to evaluate the timber resource inventory model (TRIM). This study compares model predictions with field measurements and examines the effect of inventory data aggregation on the accuracy of projections. Projections were repeated for two geographic...

  18. Method for evaluationo of the 3D residual stress field from X-ray diffraction measurements on heavy weldments

    International Nuclear Information System (INIS)

    Larsson, L.E.; Sandstroem, R.

    1982-03-01

    A method for evaluation of the three dimensional residual 30 stress distribution in heavy weldmwents has been developed. The evaluation is based on measured stress data at a number of depth levels below the plate surface. The method has been applied to two measurements on heavy weldments of A 553 B steel. Comparison to a previous evaluation shows good agreement. (Authors)

  19. Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery

    NARCIS (Netherlands)

    Knobben, BAS; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    The aim of this study was to evaluate whether behavioural and systemic measures wilt decrease intra-operative contamination during total hip or knee replacements. The influence of these measures on subsequent prolonged wound discharge, superficial surgical site infection and deep periprosthetic

  20. Reliable tool life measurements in turning - an application to cutting fluid efficiency evaluation

    DEFF Research Database (Denmark)

    Axinte, Dragos A.; Belluco, Walter; De Chiffre, Leonardo

    2001-01-01

    The paper proposes a method to obtain reliable measurements of tool life in turning, discussing some aspects related to experimental procedure and measurement accuracy. The method (i) allows and experimental determination of the extended Taylor's equation, with a limited set of experiments and (ii......) provides efficiency evaluation. Six cutting oils, five of which formulated from vegetable basestock, were evaluated in turning. Experiments were run in a range of cutting parameters. according to a 2, 3-1 factorial design, machining AISI 316L stainless steel with coated carbide tools. Tool life...

  1. Perturbation measurements in reactor LR-0 and their evaluation

    International Nuclear Information System (INIS)

    Rypar, W.; Faehrmann, K.H.

    1988-07-01

    To investigate space-dependent kinetic effects in reactors of the WWER-1000 type, two central and one eccentric perturbation measurements were performed in the zero power reactor LR-0 of the UJV Rez (CSSR) by trapeze-form movements of an absorber cluster. The measurements were based ona computer aided CAMAC system for the simultaneous data acquisition of 20 spatially distributed neutron detectors and for cluster movement control. The measurements were followed by a detailed evaluation in the ZfK Rossendorf (GDR) with respect to the calculation results of flux response obtained by nodal code HEXDYN3D, the aim of which was to demostrate the limits of the point reactor model and to account for space-dependent effects by approximative methods. A sensitive check of the calculation methods was made possible especially by the eccentric perturbation where the space dependent effects,due to a larger distance of cluster movement, were most significant. (author). 17 figs., 9 refs

  2. Performance measurement for supply chain management and evaluation criteria determination for reverse supply chain management

    Science.gov (United States)

    Kongar, N. Elif

    2004-12-01

    Today, since customers are able to obtain similar-quality products for similar prices, the lead time has become the only preference criterion for most of the consumers. Therefore, it is crucial that the lead time, i.e., the time spent from the raw material phase till the manufactured good reaches the customer, is minimized. This issue can be investigated under the title of Supply Chain Management (SCM). An efficiently managed supply chain can lead to reduced response time for customers. To achieve this, continuous observation of supply chain efficiency, i.e., a constant performance evaluation of the current SCM is required. Widely used conventional performance measurement methods lack the ability to evaluate a SCM since the supply chain is a dynamic system that requires a more thorough and flexible performance measurement technique. Balanced Scorecard (BS) is an efficient tool for measuring the performance of dynamic systems and has a proven capability of providing the decision makers with the appropriate feedback data. In addition to SCM, a relatively new management field, namely reverse supply chain management (RSCM), also necessitates an appropriate evaluation approach. RSCM differs from SCM in many aspects, i.e., the criteria used for evaluation, the high level of uncertainty involved etc., not allowing the usage of identical evaluation techniques used for SCM. This study proposes a generic Balanced Scorecard to measure the performance of supply chain management while defining the appropriate performance measures for SCM. A scorecard prototype, ESCAPE, is presented to demonstrate the evaluation process.

  3. Evaluation of the ProPublica Surgeon Scorecard "Adjusted Complication Rate" Measure Specifications.

    Science.gov (United States)

    Ban, Kristen A; Cohen, Mark E; Ko, Clifford Y; Friedberg, Mark W; Stulberg, Jonah J; Zhou, Lynn; Hall, Bruce L; Hoyt, David B; Bilimoria, Karl Y

    2016-10-01

    The ProPublica Surgeon Scorecard is the first nationwide, multispecialty public reporting of individual surgeon outcomes. However, ProPublica's use of a previously undescribed outcome measure (composite of in-hospital mortality or 30-day related readmission) and inclusion of only inpatients have been questioned. Our objectives were to (1) determine the proportion of cases excluded by ProPublica's specifications, (2) assess the proportion of inpatient complications excluded from ProPublica's measure, and (3) examine the validity of ProPublica's outcome measure by comparing performance on the measure to well-established postoperative outcome measures. Using ACS-NSQIP data (2012-2014) for 8 ProPublica procedures and for All Operations, the proportion of cases meeting all ProPublica inclusion criteria was determined. We assessed the proportion of complications occurring inpatient, and thus not considered by ProPublica's measure. Finally, we compared risk-adjusted performance based on ProPublica's measure specifications to established ACS-NSQIP outcome measure performance (eg, death/serious morbidity, mortality). ProPublica's inclusion criteria resulted in elimination of 82% of all operations from assessment (range: 42% for total knee arthroplasty to 96% for laparoscopic cholecystectomy). For all ProPublica operations combined, 84% of complications occur during inpatient hospitalization (range: 61% for TURP to 88% for total hip arthroplasty), and are thus missed by the ProPublica measure. Hospital-level performance on the ProPublica measure correlated weakly with established complication measures, but correlated strongly with readmission (R = 0.834, P Scorecard is questionable.

  4. Measuring Emotional Intelligence Enhances the Psychological Evaluation of Chronic Pain.

    Science.gov (United States)

    Doherty, Eva M; Walsh, Rosemary; Andrews, Leanne; McPherson, Susan

    2017-12-01

    The assessment of emotional factors, in addition to other psychosocial factors, has been recommended as a means of identifying individuals with chronic pain who may not respond to certain pain treatments. Systematic reviews of the evidence regarding the prediction of responsiveness to a treatment called the spinal cord stimulator (SCS) have yielded inconclusive results. Emotional intelligence is a term which refers to the ability to identify and manage emotions in oneself and others and has been shown to be inversely associated with emotional distress and acute pain. This study aims to investigate the relationship between emotional intelligence, chronic pain, and the more established psychosocial factors usually used for SCS evaluations by clinical psychologists in medical settings. A sample of 112 patients with chronic pain on an acute hospital waiting list for SCS procedures in a pain medicine service were recruited. Psychological measures were completed including: a novel measure of emotional intelligence; usual measures of emotional distress and catastrophizing; and a numerical rating scale designed to assess pain intensity, pain-related distress, and interference. As predicted, findings revealed significant associations between most of the measures analyzed and current pain intensity. When entered into a simultaneous regression analysis, emotional intelligence scores remained the only significant predictor of current pain intensity. There are potential clinical, ethical, and organizational implications of emotional intelligence processes partially predicting pain in patients on a waiting list for a medical procedure. These results may offer new insight, understanding, and evaluation targets for clinical psychologists in the field of pain management.

  5. [A new model fo the evaluation of measurements of the neurocranium].

    Science.gov (United States)

    Seidler, H; Wilfing, H; Weber, G; Traindl-Prohazka, M; zur Nedden, D; Platzer, W

    1993-12-01

    A simple and user-friendly model for trigonometric description of the neurocranium based on newly defined points of measurement is presented. This model not only provides individual description, but also allows for an evaluation of developmental and phylogenetic aspects.

  6. Determinants of the use of value-based performance measures for managerial performance evaluation

    NARCIS (Netherlands)

    Dekker, H.C.; Groot, T.L.C.M.; Schoute, M.; Wiersma, E.

    2012-01-01

    As value-based (VB) performance measures include firms' cost of capital, they are considered more congruent than earnings measures. Prior studies, however, find that their use for managerial performance evaluation is less extensive than their presumed benefits would suggest. We examine how the

  7. Measurement of social support, community and trust in dentistry

    DEFF Research Database (Denmark)

    Berthelsen, Hanne; Pejtersen, Jan Hyld; Söderfeldt, Björn

    2011-01-01

    BACKGROUND AND AIM: Relationships among people at work have previously been found to contribute to the perception of having a good work. The aim of the present paper was to develop scales measuring aspects of social support, trust, and community among dentists, and to evaluate psychometric proper...

  8. New Discrete Fibonacci Charge Pump Design, Evaluation and Measurement

    Science.gov (United States)

    Matoušek, David; Hospodka, Jiří; Šubrt, Ondřej

    2017-06-01

    This paper focuses on the practical aspects of the realisation of Dickson and Fibonacci charge pumps. Standard Dickson charge pump circuit solution and new Fibonacci charge pump implementation are compared. Both charge pumps were designed and then evaluated by LTspice XVII simulations and realised in a discrete form on printed circuit board (PCB). Finally, the key parameters as the output voltage, efficiency, rise time, variable power supply and clock frequency effects were measured.

  9. Evaluation of policy measures and methods to reduce diffuse water pollution

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Ute; Doehler, Helmut; Eurich-Menden, Brigitte; Goemann, Horst; Jaeger, Peter; Kreins, Peter; Moeller, Christine; Prigge, Achim; Ristenpart, Erik; Schultheiss, Ute

    2006-11-15

    After considerable improvements of wastewater treatment, the loads of nutrients and plant protection agents, deriving from agriculture and heavy metals from urban drainages effluents as well as from erosion of agricultural soils are the main sources of nutrients and harmful substances in the loads of water bodies. The targets of the project were on the one hand the analysis of the political and legislative framework of both policy fields and on the other hand the evaluation of several, selected water protection measures with regard to their contribution to reduce water pollution, their economical effects as well as their political enforceability. The focus was laid on diffuse water pollution caused by agriculture. As main reasons for the diffuse water pollution stagnating at high level, the analysis of the political framework identified a lack of implementation discipline of water law, followed by the fragmented and insufficient water protection legislation itself and the previous design of the common agricultural policy slanted towards increasing productivity. For the future co-operation of agricultural and water authorities in implementation of their reforms and better definition of 'Good Farming Practice' are recommended. The second investigation level focuses on the analysis and assessment of selected measures to reduce the input of nutrients and plant protection agents. This part was done with help of calculation models focussing on the specific cost/benefit ratios for water protection. In detail the following measures have been analysed: decoupling of direct payments, coupling of livestock farming to areas, tax on mineral nitrogen, pesticide levy, buffer stripes alongside of watercourses, all season crop cover on arable land, soil cultivation procedures, changing the use of arable land, optimisation of animal nutrition, optimisation of manure storage and application, co-operative agreements, education and training. Co-operations and water protection

  10. Measurement-Based Performance Evaluation of Advanced MIMO Transceiver Designs

    Directory of Open Access Journals (Sweden)

    Schneider Christian

    2005-01-01

    Full Text Available This paper describes the methodology and the results of performance investigations on a multiple-input multiple-output (MIMO transceiver scheme for frequency-selective radio channels. The method relies on offline simulations and employs real-time MIMO channel sounder measurement data to ensure a realistic channel modeling. Thus it can be classified in between the performance evaluation using some predefined channel models and the evaluation of a prototype hardware in field experiments. New aspects for the simulation setup are discussed, which are frequently ignored when using simpler model-based evaluations. Example simulations are provided for an iterative ("turbo" MIMO equalizer concept. The dependency of the achievable bit error rate performance on the propagation characteristics and on the variation in some system design parameters is shown, whereas the antenna constellation is of particular concern for MIMO systems. Although in many of the considered constellations turbo MIMO equalization appears feasible in real field scenarios, there exist cases with poor performance as well, indicating that in practical applications link adaptation of the transmitter and receiver processing to the environment is necessary.

  11. Economic evaluation of energy saving measures in a common type of Greek building

    International Nuclear Information System (INIS)

    Nikolaidis, Yiannis; Pilavachi, Petros A.; Chletsis, Alexandros

    2009-01-01

    This paper deals with the economic analysis and evaluation of various energy saving measures in the building sector, focusing on a domestic detached house in Greece, i.e. in a typical Mediterranean climate. In order to detect the energy saving measures that, in addition to energy benefits, can also provide economic profits, the study examines the following measures: all kinds of insulation; upgrading of the heating system; use of thermal solar systems; upgrading of lighting; upgrading of electric appliances; upgrading of the cooling system. The economic evaluation methods used for ranking the energy saving measures are the Net Present Value, the Internal Rate of Return, the Savings to Investment Ratio and the Depreciated Payback Period. It has been found that amongst the most effective energy saving methods are the upgrading of lighting, the insulation of the roof of the building and the installation of an automatic temperature control system.

  12. Psychometric evaluation of a daily gastro-oesophageal reflux disease symptom measure.

    Science.gov (United States)

    Bytzer, Peter; Reimer, Christina; Smith, Gary; Anatchkova, Milena D; Hsieh, Ray; Wilkinson, Joanne; Thomas, S Jane; Lenderking, William R

    2017-03-01

    The objective of this study was to evaluate the validity of the Heartburn Reflux Dyspepsia Questionnaire (HRDQ), a newly developed measure of gastro-oesophageal reflux disease (GORD) symptoms. Specifically, the HRDQ was developed for patients, who still experience symptoms with proton pump inhibitor (PPI) treatment. The psychometric properties of HRDQ were evaluated based on data from two clinical trials of patients with GORD with a partial response to PPIs, one from the UK and one from Denmark and Germany. The HRDQ had good internal consistency (Cronbach's alpha range .83-.88) and test-retest reliability (intraclass correlation coefficient range .71-.90). Convergent and discriminant validity were supported by high correlations with ReQuest™ and ability to differentiate between groups based on ReQuest™ cut-off values. Responsiveness of HRDQ was demonstrated by moderate to high correlations with ReQuest™ change scores and time with symptoms. An HRDQ cut-off value of 0.70 for definition of 'bad day' was also evaluated. Based on existing evidence, the HRDQ is a valid and reliable measure of GORD symptoms that can be used as a study outcome in clinical trials.

  13. Gaining knowledge from previously unexplained spectra-application of the PTM-Explorer software to detect PTM in HUPO BPP MS/MS data.

    Science.gov (United States)

    Chamrad, Daniel C; Körting, Gerhard; Schäfer, Heike; Stephan, Christian; Thiele, Herbert; Apweiler, Rolf; Meyer, Helmut E; Marcus, Katrin; Blüggel, Martin

    2006-09-01

    A novel software tool named PTM-Explorer has been applied to LC-MS/MS datasets acquired within the Human Proteome Organisation (HUPO) Brain Proteome Project (BPP). PTM-Explorer enables automatic identification of peptide MS/MS spectra that were not explained in typical sequence database searches. The main focus was detection of PTMs, but PTM-Explorer detects also unspecific peptide cleavage, mass measurement errors, experimental modifications, amino acid substitutions, transpeptidation products and unknown mass shifts. To avoid a combinatorial problem the search is restricted to a set of selected protein sequences, which stem from previous protein identifications using a common sequence database search. Prior to application to the HUPO BPP data, PTM-Explorer was evaluated on excellently manually characterized and evaluated LC-MS/MS data sets from Alpha-A-Crystallin gel spots obtained from mouse eye lens. Besides various PTMs including phosphorylation, a wealth of experimental modifications and unspecific cleavage products were successfully detected, completing the primary structure information of the measured proteins. Our results indicate that a large amount of MS/MS spectra that currently remain unidentified in standard database searches contain valuable information that can only be elucidated using suitable software tools.

  14. Evaluation of the Automatic Density Compensation for Pressurizer Level Measurement

    International Nuclear Information System (INIS)

    Jeong, Insoo; Min, Seohong; Ahn, Myunghoon

    2014-01-01

    When using two transmitters, it is difficult for the operators to identify the correct level of the pressurizer (PZR) upon failure of one of the two transmitters. For this reason, Korean Utility Requirements Document (KURD) requires that the operators to use three independent level indicators. Two hot calibrated transmitters and one cold calibrated transmitter compose PZR level transmitters in APR1400. In this paper, the deviation between cold calibration and hot calibration is evaluated, and the application of compensated PZR level measurement and uncompen-sated PZR level measurement during the normal operation of APR1400 are introduced. The PZR level signals for APR1400 come in three channels. To satisfy the KURD requirements for PZR level measurement, and at the same time to accomplish correction design and implementation, applicability and differences between hot calibration and cold calibration, compensated level and uncompensated level were evaluated as follows: For proper indication of PZR levels under normal operating condition, two of the three transmitters went through hot calibration and the remaining one transmitter went through cold calibration. This was to allow indicating entire regions of PZR regardless of the plant operation modes. For automatic density compensation per KURD requirements, the algorithm of the density compensated PZR level implemented in the DCS controller and PRV logic is adopted as a signal validation method

  15. Evaluation of spectrum measurement devices for operational use

    CERN Document Server

    Devine, R T; Gray, D W; Seagraves, D T; Olsher, R H; Johnson, J P

    2002-01-01

    Several neutron spectrometers manufactured by Bubble Technology Industries (BTI) were tested and evaluated in a variety of neutron fields. Findings and conclusions are presented for the following BTI instruments: a modification of the Rotational Spectrometer (ROSPEC) that includes a thermal and epithermal capability, the Simple Scintillation Spectrometer that is used in conjunction with the ROSPEC to extend its high-energy range, and the MICROSPEC N-Probe which is capable of providing a crude spectrum over the energy range from thermal to 18 MeV. The main objective of these measurements was to determine the accuracy of both the energy spectrum and dose equivalent information generated by these devices. In addition, the dose response of the Wide-Energy Neutron Detection Instrument (WENDI-II) was measured in all neutron fields relative to a bare sup 2 sup 5 sup 2 Cf calibration. The performance of the WENDI-II rem meter was compared to the dose information generated by the neutron spectrometers. The instruments...

  16. Visual Working Memory Supports the Inhibition of Previously Processed Information: Evidence from Preview Search

    Science.gov (United States)

    Al-Aidroos, Naseem; Emrich, Stephen M.; Ferber, Susanne; Pratt, Jay

    2012-01-01

    In four experiments we assessed whether visual working memory (VWM) maintains a record of previously processed visual information, allowing old information to be inhibited, and new information to be prioritized. Specifically, we evaluated whether VWM contributes to the inhibition (i.e., visual marking) of previewed distractors in a preview search.…

  17. Evaluation of sperm motility with CASA-Mot: which factors may influence our measurements?

    Science.gov (United States)

    Yeste, Marc; Bonet, Sergi; Rodríguez-Gil, Joan E; Rivera Del Álamo, Maria M

    2018-03-14

    Computer-aided sperm analysis (CASA) is now routinely used in IVF clinics, animal breeding centres and research laboratories. Although CASA provides a more objective way to evaluate sperm parameters, a significant number of factors can affect these measurements. This paper classifies these factors into four categories: (1) sample and slide (e.g. preincubation time, type of specimen and type of chamber slide); (2) microscope (e.g. light source and microscope stage); (3) hardware and software, including the settings of each system; and (4) user-related factors. We review the effects of the different factors in each category on the measurements made and emphasise the need to take measures to standardise evaluations. The take-home message of the present article is that there are several commercial and useful CASA systems, and all are appropriate for routine analysis. Non-commercial systems may also be good choices when the user needs to adapt the device to specific experimental conditions. In both cases (commercial and non-commercial), it is important that standard protocols are put in place for evaluation, as well as methods to validate the system.

  18. Quantitative assessment of skin erythema due to radiotherapy--evaluation of different measurements

    International Nuclear Information System (INIS)

    Wengstroem, Yvonne; Forsberg, Christina; Naeslund, Ingemar; Bergh, Jonas

    2004-01-01

    Background and purpose: Visual assessment is the most common clinical investigation of skin reactions in radiotherapy. Due to the unquantitative and subjective nature of this method additional non-invasive methods are needed for more accurate evaluation of the visible acute adverse skin reactions due to radiotherapy. The purpose of this study was to evaluate a new objective measure with regard to reliability and validity and compare it with an established objective measure and a visual assessment. Patients and methods: A sample of 53 consecutive patients commencing curative tangential radiation therapy to the breast parenchyma were included in the study. The skin area of the treated breast was divided into five sections and assessed individually at 0, 24 and 50 Gy. The RTOG scoring system was used for the visual assessment of the skin reactions. The first objective measure included reflectance spectrometry (DermaSpectrometer) measures at fixed points within the treatment area. For the second objective measure digital images (Camera) were taken with a system using a digital camera and software. The images were analyzed using the Adobe Photoshop 5.0 software program. Results: The results provided significant evidence of the test-retest reliability of the camera. The correlation between the objective measures proved to be significant as the treatment progressed. Conclusions: The results suggest that the camera may be used in a reliable and valid way to measure skin erythema due to radiotherapy

  19. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan; Fidelis, Krzysztof; Tramontano, Anna; Kryshtafovych, Andriy

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures

  20. Evaluation of uncertainty in the measurement of sense of natural language constructions

    Directory of Open Access Journals (Sweden)

    Bisikalo Oleg V.

    2017-01-01

    Full Text Available The task of evaluating uncertainty in the measurement of sense in natural language constructions (NLCs was researched through formalization of the notions of the language image, formalization of artificial cognitive systems (ACSs and the formalization of units of meaning. The method for measuring the sense of natural language constructions incorporated fuzzy relations of meaning, which ensures that information about the links between lemmas of the text is taken into account, permitting the evaluation of two types of measurement uncertainty of sense characteristics. Using developed applications programs, experiments were conducted to investigate the proposed method to tackle the identification of informative characteristics of text. The experiments resulted in dependencies of parameters being obtained in order to utilise the Pareto distribution law to define relations between lemmas, analysis of which permits the identification of exponents of an average number of connections of the language image as the most informative characteristics of text.

  1. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  2. A new methodology for non-contact accurate crack width measurement through photogrammetry for automated structural safety evaluation

    International Nuclear Information System (INIS)

    Jahanshahi, Mohammad R; Masri, Sami F

    2013-01-01

    In mechanical, aerospace and civil structures, cracks are important defects that can cause catastrophes if neglected. Visual inspection is currently the predominant method for crack assessment. This approach is tedious, labor-intensive, subjective and highly qualitative. An inexpensive alternative to current monitoring methods is to use a robotic system that could perform autonomous crack detection and quantification. To reach this goal, several image-based crack detection approaches have been developed; however, the crack thickness quantification, which is an essential element for a reliable structural condition assessment, has not been sufficiently investigated. In this paper, a new contact-less crack quantification methodology, based on computer vision and image processing concepts, is introduced and evaluated against a crack quantification approach which was previously developed by the authors. The proposed approach in this study utilizes depth perception to quantify crack thickness and, as opposed to most previous studies, needs no scale attachment to the region under inspection, which makes this approach ideal for incorporation with autonomous or semi-autonomous mobile inspection systems. Validation tests are performed to evaluate the performance of the proposed approach, and the results show that the new proposed approach outperforms the previously developed one. (paper)

  3. Voltammetry Method Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoyt, N. [Argonne National Lab. (ANL), Argonne, IL (United States); Pereira, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Willit, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Williamson, M. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-07-29

    The purpose of the ANL MPACT Voltammetry project is to evaluate the suitability of previously developed cyclic voltammetry techniques to provide electroanalytical measurements of actinide concentrations in realistic used fuel processing scenarios. The molten salts in these scenarios are very challenging as they include high concentrations of multiple electrochemically active species, thereby creating a variety of complications. Some of the problems that arise therein include issues related to uncompensated resistance, cylindrical diffusion, and alloying of the electrodeposited metals. Improvements to the existing voltammetry technique to account for these issues have been implemented, resulting in good measurements of actinide concentrations across a wide range of adverse conditions.

  4. Psychometric evaluation of a daily gastro-oesophageal reflux disease symptom measure

    DEFF Research Database (Denmark)

    Bytzer, Peter; Reimer, Christina; Smith, Gary

    2017-01-01

    was demonstrated by moderate to high correlations with ReQuest™ change scores and time with symptoms. An HRDQ cut-off value of 0.70 for definition of ‘bad day’ was also evaluated. Conclusions: Based on existing evidence, the HRDQ is a valid and reliable measure of GORD symptoms that can be used as a study outcome...... (Cronbach’s alpha range.83–.88) and test–retest reliability (intraclass correlation coefficient range.71–.90). Convergent and discriminant validity were supported by high correlations with ReQuest™ and ability to differentiate between groups based on ReQuest™ cut-off values. Responsiveness of HRDQ......Objective: The objective of this study was to evaluate the validity of the Heartburn Reflux Dyspepsia Questionnaire (HRDQ), a newly developed measure of gastro-oesophageal reflux disease (GORD) symptoms. Specifically, the HRDQ was developed for patients, who still experience symptoms with proton...

  5. A Critical Evaluation of Quantitative Measures of the Quality of Arts and Culture

    DEFF Research Database (Denmark)

    Bille, Trine

    Art and culture i.e. theatre, film, music, visual art, literature, cultural heritage etc. and related institutions and participants, have traditionally not been measured and evaluated in the same way as other sectors. The reason for this is perhaps that art and culture cannot be ‘weighed and meas......Art and culture i.e. theatre, film, music, visual art, literature, cultural heritage etc. and related institutions and participants, have traditionally not been measured and evaluated in the same way as other sectors. The reason for this is perhaps that art and culture cannot be ‘weighed...

  6. New Discrete Fibonacci Charge Pump Design, Evaluation and Measurement

    Directory of Open Access Journals (Sweden)

    Matoušek David

    2017-06-01

    Full Text Available This paper focuses on the practical aspects of the realisation of Dickson and Fibonacci charge pumps. Standard Dickson charge pump circuit solution and new Fibonacci charge pump implementation are compared. Both charge pumps were designed and then evaluated by LTspice XVII simulations and realised in a discrete form on printed circuit board (PCB. Finally, the key parameters as the output voltage, efficiency, rise time, variable power supply and clock frequency effects were measured.

  7. Alternative Student Growth Measures for Teacher Evaluation: Implementation Experiences of Early-Adopting Districts. REL 2015-093

    Science.gov (United States)

    McCullough, Moira; English, Brittany; Angus, Megan Hague; Gill, Brian

    2015-01-01

    Alternative student growth measures for teacher evaluation: Implementation experiences of early-adopting districts: State requirements to include student achievement growth in teacher evaluations are prompting the development of alternative ways to measure growth in grades and subjects not covered by state assessments. These alternative growth…

  8. Evaluation of surface contamination based on certifiably traceable, internationally accreditable measurements

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1992-01-01

    National Accreditation and Measurement Service (NAMAS) adopted by the EUROMET agreement requires that the calibration of monitoring instruments be traceable internationally with the objective that radiation hazard assessment be improved. This objective is achieved for Tritium surface contamination by employing calibration sources and evaluation methods which comply with ISO standards including the measurement of activity removable by Volatilization as well as dust. Consideration should be given to organic binding of tritium in the skin with its implications in the event of litigation. (author)

  9. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  10. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  11. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Science.gov (United States)

    Brunke, Heinz-Peter; Matzka, Jürgen

    2018-01-01

    At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer). Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination) measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996).We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters) of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017).

  12. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Directory of Open Access Journals (Sweden)

    H.-P. Brunke

    2018-01-01

    Full Text Available At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer. Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996.We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017.

  13. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan; D'Andrea, Daniel; Fidelis, Krzysztof; Tramontano, Anna; Kryshtafovych, Andriy

    2013-01-01

    not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i

  14. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  15. Measuring Safeguards Culture

    International Nuclear Information System (INIS)

    Frazar, Sarah L.; Mladineo, Stephen V.

    2011-01-01

    As the International Atomic Energy Agency (IAEA) implements a State Level Approach to its safeguards verification responsibilities, a number of countries are beginning new nuclear power programs and building new nuclear fuel cycle faculties. The State Level approach is holistic and investigatory in nature, creating a need for transparent, non-discriminatory judgments about a state's nonproliferation posture. In support of this need, the authors previously explored the value of defining and measuring a state's safeguards culture. We argued that a clear definition of safeguards culture and an accompanying set of metrics could be applied to provide an objective evaluation and demonstration of a country's nonproliferation posture. As part of this research, we outlined four high-level metrics that could be used to evaluate a state's nuclear posture. We identified general data points. This paper elaborates on those metrics, further refining the data points to generate a measurable scale of safeguards cultures. We believe that this work could advance the IAEA's goals of implementing a safeguards system that is fully information driven, while strengthening confidence in its safeguards conclusions.

  16. Evaluation of a new carotid intima-media thickness measurement by B-mode ultrasonography using an innovative measurement software, intimascope.

    Science.gov (United States)

    Yanase, Toshihiko; Nasu, Shigeru; Mukuta, Yoshihiro; Shimizu, Yutaka; Nishihara, Tetsu; Okabe, Taijiro; Nomura, Masatoshi; Inoguchi, Toyoshi; Nawata, Hajime

    2006-12-01

    Carotid intima-media thickness (IMT), an indicator of atherosclerosis and coronary heart disease (CHD) is usually evaluated by eye measurement under B-scope carotid artery ultrasonography. However, the axial resolution of this system is >/=0.1 mm, which causes difficulties in respect to accuracy and reproducibility. We evaluated a newly developed B-scope carotid artery ultrasonography programmed by an innovative measurement software, Intimascope (Media Cross Co. Ltd., Tokyo, Japan), which measures IMT with 10 times higher axial resolution at an estimated scale of 0.01 mm. Intraobserver or interobserver coefficient of variation (CV) of the computer-based average IMT (aver-IMT) value and 3-point IMT value were much smaller than the corresponding value by conventional eye-measurement method (3-point value). We measured IMT of 427 asymptomatic subjects undergoing medical checkups (243 men and 184 women, 23 to 73 years of age). Although the mean values of aver-IMT and 3-point IMT of 427 subjects were comparable with that of the eye measurement method, the aver-IMT showed the smallest SD (standard deviation) and CV values. In both men and women, multivariate regression analysis revealed significant contributions of age and LDL-C to the aver-IMT value. Univariate regression analysis revealed that the aver-IMT value of total subjects showed the highest correlation coefficient values with most risk factors and risk assessment score, Framingham Risk Assessment, or Prospective Cardiovascular Munster study (PROCAM) Risk Score. These results may suggest superiority of computer-based aver-IMT over 3-point IMT by either computer-based or eye measurement method. Carotid aver-IMT measurement using the new Intimascope software may provide a more precise and reproducible index of atherosclerosis than does conventional IMT measurement.

  17. Evaluation of animal control measures on pet demographics in Santa Clara County, California, 1993–2006

    Directory of Open Access Journals (Sweden)

    Philip H. Kass

    2013-02-01

    Full Text Available The measurable benefits of animal control programs are unknown and the aim of this study was to determine the impact of these programs on pet population changes. A prospective cross-sectional study of 1000 households was implemented in 2005 to evaluate characteristics of the owned and unowned population of dogs and cats in Santa Clara County, California. The same population was previously studied 12 years earlier. During this time period, the county instituted in 1994 and then subsequently disestablished a municipal spay/neuter voucher program for cats. Dog intakes declined from 1992–2005, as they similarly did for an adjacent county (San Mateo. However, cat intakes declined significantly more in Santa Clara County than San Mateo, with an average annual decline of approximately 700 cats for the 12 year period. Time series analysis showed a greater than expected decline in the number of cats surrendered to shelters in Santa Clara County during the years the voucher program was in effect (1994–2005. The net savings to the county by reducing the number of cat shelter intakes was estimated at approximately $1.5 million. The measurable benefits of animal control programs are unknown and the aim of this study was to determine the impact of these programs on pet population changes.

  18. Sensor Prototype to Evaluate the Contact Force in Measuring with Coordinate Measuring Arms

    Directory of Open Access Journals (Sweden)

    Eduardo Cuesta

    2015-06-01

    Full Text Available This paper describes the design, development and evaluation tests of an integrated force sensor prototype for portable Coordinate Measuring Arms (CMAs or AACMMs. The development is based on the use of strain gauges located on the surface of the CMAs’ hard probe. The strain gauges as well as their cables and connectors have been protected with a custom case, made by Additive Manufacturing techniques (Polyjet 3D. The same method has been selected to manufacture an ergonomic handle that includes trigger mechanics and the electronic components required for synchronizing the trigger signal when probing occurs. The paper also describes the monitoring software that reads the signals in real time, the calibration procedure of the prototype and the validation tests oriented towards increasing knowledge of the forces employed in manual probing. Several experiments read and record the force in real time comparing different ways of probing (discontinuous and continuous contact and measuring different types of geometric features, from single planes to exterior cylinders, cones, or spheres, through interior features. The probing force is separated into two components allowing the influence of these strategies in probe deformation to be known. The final goal of this research is to improve the probing technique, for example by using an operator training programme, allowing extra-force peaks and bad contacts to be minimized or just to avoid bad measurements.

  19. Linear and Non-linear Numerical Sea-keeping Evaluation of a Fast Monohull Ferry Compared to Full Scale Measurements

    DEFF Research Database (Denmark)

    Wang, Zhaohui; Folsø, Rasmus; Bondini, Francesca

    1999-01-01

    , full-scale measurements have been performed on board a 128 m monohull fast ferry. This paper deals with the results from these full-scale measurements. The primary results considered are pitch motion, midship vertical bending moment and vertical acceleration at the bow. Previous comparisons between...

  20. Evaluation and development plan of NRTA measurement methods for the Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Li, T.K.; Hakkila, E.A.; Flosterbuer, S.F.

    1995-01-01

    Near-real-time accounting (NRTA) has been proposed as a safeguards method at the Rokkasho Reprocessing Plant (RRP), a large-scale commercial boiling water and pressurized water reactors spent-fuel reprocessing facility. NRTA for RRP requires material balance closures every month. To develop a more effective and practical NRTA system for RRP, we have evaluated NRTA measurement techniques and systems that might be implemented in both the main process and the co-denitration process areas at RRP to analyze the concentrations of plutonium in solutions and mixed oxide powder. Based on the comparative evaluation, including performance, reliability, design criteria, operation methods, maintenance requirements, and estimated costs for each possible measurement method, recommendations for development were formulated. This paper discusses the evaluations and reports on the recommendation of the NRTA development plan for potential implementation at RRP

  1. Adverse obstetric outcomes in women with previous cesarean for dystocia in second stage of labor.

    Science.gov (United States)

    Jastrow, Nicole; Demers, Suzanne; Gauthier, Robert J; Chaillet, Nils; Brassard, Normand; Bujold, Emmanuel

    2013-03-01

    To evaluate obstetric outcomes in women undergoing a trial of labor (TOL) after a previous cesarean for dystocia in second stage of labor. A retrospective cohort study of women with one previous low transverse cesarean undergoing a first TOL was performed. Women with previous cesarean for dystocia in first stage and those with previous dystocia in second stage were compared with those with previous cesarean for nonrecurrent reasons (controls). Multivariable regressions analyses were performed. Of 1655 women, those with previous dystocia in second stage of labor (n = 204) had greater risks than controls (n = 880) to have an operative delivery [odds ratio (OR): 1.5; 95% confidence intervals (CI) 1.1 to 2.2], shoulder dystocia (OR: 2.9; 95% CI 1.1 to 8.0), and uterine rupture in the second stage of labor (OR: 4.9; 95% CI 1.1 to 23), and especially in case of fetal macrosomia (OR: 29.6; 95% CI 4.4 to 202). The median second stage of labor duration before uterine rupture was 2.5 hours (interquartile range: 1.5 to 3.2 hours) in these women. Previous cesarean for dystocia in the second stage of labor is associated with second-stage uterine rupture at next delivery, especially in cases of suspected fetal macrosomia and prolonged second stage of labor. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Precision evaluation of dual X-ray absorptiometry (iDXA) measurements

    International Nuclear Information System (INIS)

    Yu Wei; Lin Qiang; Yu Xiaobo; Yao Jinpeng

    2009-01-01

    Objective: To evaluate the precision of the iDXA measurements for lumbar spine, proximal femur and whole body bone density as well as body composition (lean and fat). Methods: The study recruited randomly 30 volunteers. Each subject was scanned by iDXA twice in the same day. Measurement sites included lumbar spine, proximal femur and whole body. Precision errors were expressed as root mean square of CV (RMS-CV). Results: Mean precision errors of bone density measurements at lumbar spine, femoral neck, Ward's triangle, great trochanter and total femur ranged from 0.8% to 2.0%, with the lowest of 0.8% at both lumbar spine and total femur, as well as with the highest of 2.0% at ward' s triangle; Mean precision errors of bone density measurements at whole body and its individual site ranged from 0.7% to 2.0%, with the lowest of 0.7% for the whole body measurement, mean precision errors of lean measurements at whole body and its individual site ranged from 0.6% to 2.1%, with the lowest of 0.6% for the whole body lean measurement; Mean precision errors of fat measurements at whole body and its individual site ranged from 1.0% to 3.2%, with the lowest of 1.0% for the whole body fat measurement. Conclusion: Measurement precision of iDXA at lumbar spine, proximal femur and whole body bone density could meet clinical needs; Precision values of the measurements of whole body and its individual composition may be helpful for future clinical use. (authors)

  3. Low-dose computed tomography image restoration using previous normal-dose scan

    International Nuclear Information System (INIS)

    Ma, Jianhua; Huang, Jing; Feng, Qianjin; Zhang, Hua; Lu, Hongbing; Liang, Zhengrong; Chen, Wufan

    2011-01-01

    Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use

  4. Metric Indices for Performance Evaluation of a Mixed Measurement based State Estimator

    Directory of Open Access Journals (Sweden)

    Paula Sofia Vide

    2013-01-01

    Full Text Available With the development of synchronized phasor measurement technology in recent years, it gains great interest the use of PMU measurements to improve state estimation performances due to their synchronized characteristics and high data transmission speed. The ability of the Phasor Measurement Units (PMU to directly measure the system state is a key over SCADA measurement system. PMU measurements are superior to the conventional SCADA measurements in terms of resolution and accuracy. Since the majority of measurements in existing estimators are from conventional SCADA measurement system, it is hard to be fully replaced by PMUs in the near future so state estimators including both phasor and conventional SCADA measurements are being considered. In this paper, a mixed measurement (SCADA and PMU measurements state estimator is proposed. Several useful measures for evaluating various aspects of the performance of the mixed measurement state estimator are proposed and explained. State Estimator validity, performance and characteristics of the results on IEEE 14 bus test system and IEEE 30 bus test system are presented.

  5. An Independent Psychometric Evaluation of the PROMS Measure of Music Perception Skills.

    Science.gov (United States)

    Kunert, Richard; Willems, Roel M; Hagoort, Peter

    2016-01-01

    The Profile of Music Perception Skills (PROMS) is a recently developed measure of perceptual music skills which has been shown to have promising psychometric properties. In this paper we extend the evaluation of its brief version to three kinds of validity using an individual difference approach. The brief PROMS displays good discriminant validity with working memory, given that it does not correlate with backward digit span (r = .04). Moreover, it shows promising criterion validity (association with musical training (r = .45), musicianship status (r = .48), and self-rated musical talent (r = .51)). Finally, its convergent validity, i.e. relation to an unrelated measure of music perception skills, was assessed by correlating the brief PROMS to harmonic closure judgment accuracy. Two independent samples point to good convergent validity of the brief PROMS (r = .36; r = .40). The same association is still significant in one of the samples when including self-reported music skill in a partial correlation (rpartial = .30; rpartial = .17). Overall, the results show that the brief version of the PROMS displays a very good pattern of construct validity. Especially its tuning subtest stands out as a valuable part for music skill evaluations in Western samples. We conclude by briefly discussing the choice faced by music cognition researchers between different musical aptitude measures of which the brief PROMS is a well evaluated example.

  6. Does parental divorce moderate the heritability of body dissatisfaction? An extension of previous gene-environment interaction effects.

    Science.gov (United States)

    O'Connor, Shannon M; Klump, Kelly L; VanHuysse, Jessica L; McGue, Matt; Iacono, William

    2016-02-01

    Previous research suggests that parental divorce moderates genetic influences on body dissatisfaction. Specifically, the heritability of body dissatisfaction is higher in children of divorced versus intact families, suggesting possible gene-environment interaction effects. However, prior research is limited to a single, self-reported measure of body dissatisfaction. The primary aim of this study was to examine whether these findings extend to a different dimension of body dissatisfaction: body image perceptions. Participants were 1,534 female twins from the Minnesota Twin Family Study, aged 16-20 years. The Body Rating Scale (BRS) was used to assess body image perceptions. Although BRS scores were heritable in twins from divorced and intact families, the heritability estimates in the divorced group were not significantly greater than estimates in the intact group. However, there were differences in nonshared environmental effects, where the magnitude of these environmental influences was larger in the divorced as compared with the intact families. Different dimensions of body dissatisfaction (i.e., negative self-evaluation versus body image perceptions) may interact with environmental risk, such as parental divorce, in discrete ways. Future research should examine this possibility and explore differential gene-environment interactions using diverse measures. © 2015 Wiley Periodicals, Inc.

  7. Uncertainty evaluation of thickness and warp of a silicon wafer measured by a spectrally resolved interferometer

    Science.gov (United States)

    Praba Drijarkara, Agustinus; Gergiso Gebrie, Tadesse; Lee, Jae Yong; Kang, Chu-Shik

    2018-06-01

    Evaluation of uncertainty of thickness and gravity-compensated warp of a silicon wafer measured by a spectrally resolved interferometer is presented. The evaluation is performed in a rigorous manner, by analysing the propagation of uncertainty from the input quantities through all the steps of measurement functions, in accordance with the ISO Guide to the Expression of Uncertainty in Measurement. In the evaluation, correlation between input quantities as well as uncertainty attributed to thermal effect, which were not included in earlier publications, are taken into account. The temperature dependence of the group refractive index of silicon was found to be nonlinear and varies widely within a wafer and also between different wafers. The uncertainty evaluation described here can be applied to other spectral interferometry applications based on similar principles.

  8. Evaluation of screen-film system quality: physical principles and measurement techniques

    International Nuclear Information System (INIS)

    Borasi, G.; Berardi, P.; Ferretti, P.P.; Piccagli, V.

    1990-01-01

    Comparative evaluation of radiographic filmscreen systems presents several problems from both the theoretical and the experimental point of view. From the theoretical point of view the main difficulties are related to the choice of the parameters best suited to express the 'overall quality' of a system. From the practical point of view the main problem is that to measure some basic quantities (resolution and noise) sophisticated and expensive instruments are required. This paper deals with both these problems. To express image quality we have assumed the signal-to-noise power ration: this index depends in a explicit way on contrast, resolution and noise of the system. The dependence on sensitivity is implicit and was derived using literature data. From a knowledge of the dependence of image quality on sensitivity it is possible to develop an 'overall quality' index which is considered to express the 'technological level' of the systems. In this work some basic phisical quantities (characteristic curve, sensitivity) were evaluated using standard instruments. To measure spatial resolution and noise an inexpensive, PC-based, TV-digitizer system was developed. As an example, both image and overall quality indices were evaluated on three mammographic systems which are typical of the three different 'phases' of the development of this technique

  9. Evaluation of technological measures to cope with climate change

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Hiroshi; Moriguchi, Yulchi [National Inst. for Environmental Studies, Onogawa Tsukuba (Japan)

    1993-12-31

    Because the global warming (climate change) is recognized as a highly probable phenomenon in the next century, the countermeasures to cope with this issue is really Important. International discussion Is progressing towards the conclusion of the treaty to stabilize global warming. Therefore, now is the time to take concrete action to reduce the emission to the greenhouse gases (GHG). To find the way to reduce the emission of the GHG, the procedure as next should be taken. (1) Systematic estimation of GHG emission (GHG analysis), (2) Identification of conventional and Innovative technologies, (3) Assessment of individual sectoral technologies, (4) Comprehensive evaluation of countermeasures as a whole. Both in the U.S.A. and Japan, this kind of research have been made independently. Among these processes, the standard methodologies should be established on the GHG analysis, the assessment of individual technologies and the comprehensive evaluation. From such a background, it is important to discuss the way to evaluate technological measures to cope with climate change between the specialist from the U.S.A. and Japan. And still required to search the possibility to establish a joint project between both countries.

  10. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  11. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  12. Evaluating the effectiveness of using electroencephalogram power indices to measure visual fatigue.

    Science.gov (United States)

    Hsu, Bin-Wei; Wang, Mao-Jiun J

    2013-02-01

    Electroencephalography (EEG) is widely used in cognitive and behavioral research. This study evaluates the effectiveness of using the EEG power index to measure visual fatigue. Three common visual fatigue measures, critical-flicker fusion (CFF), near-point accommodation (NPA), and subjective eye-fatigue rating, were used for comparison. The study participants were 20 men with a mean age of 20.4 yr. (SD = 1.5). The experimental task was a car-racing video game. Results indicated that the EEG power indices were valid as a visual fatigue measure and the sensitivity of the objective measures (CFF and EEG power index) was higher than the subjective measure. The EEG beta and EEG alpha were effective for measuring visual fatigue in short- and long-duration tasks, respectively. EEG beta/alpha were the most effective power indexes for the visual fatigue measure.

  13. The Relationship between Teachers' Attitudes toward Measurement and Evaluation and Their Perceptions of Professional Well-Being

    Science.gov (United States)

    Yildirim, Kamil; Arastaman, Gökhan; Dasci, Elif

    2016-01-01

    Problem Statement: The quality of teaching at schools mostly depends on the teachers' competencies. One of these competencies is measurement and evaluation (MaE). Evaluation of the students' cognitive, affective, and psychomotor development requires skills and knowledge about various measuring tools and techniques. It is essential for a teacher to…

  14. Fission neutron output measurements at LANSCE

    International Nuclear Information System (INIS)

    Nelson, Ronald Owen; Haight, Robert C.; Devlin, Matthew J.; Fotiadis, Nikolaos; Laptev, Alexander; O'Donnell, John M.; Taddeucci, Terry N.; Tovesson, Fredrik; Ullmann, J.L.; Wender, Stephen A.; Bredeweg, T.A.; Jandel, M.; Vieira, D.J.; Wu, Ching-Yen; Becker, J.A.; Stoyer, M.A.; Henderson, R.; Sutton, M.; Belier, Gilbert; Chatillon, A.; Granier, Thierry; Laurent, Benoit; Taieb, Julien

    2010-01-01

    Accurate data for both physical properties and fission properties of materials are necessary to properly model dynamic fissioning systems. To address the need for accurate data on fission neutron energy spectra, especially at outgoing neutron energies below about 200 keV and at energies above 8 MeV, ongoing work at LANSCE involving collaborators from LANL, LLNL and CEA Bruyeres-le-Chatel is extending the energy range, efficiency and accuracy beyond previous measurements. Initial work in the outgoing neutron energy range from 1 to 7 MeV is consistent with current evaluations and provides a foundation for extended measurements. As part of these efforts, a new fission fragment detector that reduces backgrounds and improves timing has been designed fabricated and tested, and new neutron detectors are being assessed for optimal characteristics. Simulations of experimental designs are in progress to ensure that accuracy goals are met. Results of these measurements will be incorporated into evaluations and data libraries as they become available.

  15. The measurement of place attachment: validity and generalizability of a psychometric approach

    Science.gov (United States)

    Daniel R. Williams; Jerry J. Vaske

    2003-01-01

    To enhance land managers’ ability to address deeper landscape meanings and place-specific symbolic values in natural resource decision making, this study evaluated the psychometric properties of a place attachment measure designed to capture the extent of emotions and feelings people have for places. Building on previous measurement efforts, this study examined the...

  16. Seat pressure measurement technologies: considerations for their evaluation.

    Science.gov (United States)

    Gyi, D E; Porter, J M; Robertson, N K

    1998-04-01

    Interface pressure measurement has generated interest in the automotive industry as a technique which could be used in the prediction of driver discomfort for various car seat designs, and provide designers and manufacturers with rapid information early on in the design process. It is therefore essential that the data obtained are of the highest quality, relevant and have some quantitative meaning. Exploratory experimental work carried out with the commercially available Talley Pressure Monitor is outlined. This led to a better understanding of the strengths and weaknesses of this system and the re-design of the sensor matrix. Such evaluation, in the context of the actual experimental environment, is considered essential.

  17. Evaluation of stress gradient by x-ray stress measurement based on change in angle phi

    International Nuclear Information System (INIS)

    Sasaki, Toshihiko; Kuramoto, Makoto; Yoshioka, Yasuo.

    1985-01-01

    A new principle of X-ray stress evaluation for a sample with steep stress gradient has been prosed. The feature of this method is that the stress is determined by using so-called phi-method based on the change of phi-angle and thus has no effect on the penetration depth of X-rays. The procedure is as follows; firstly, an average stress within the penetration depth of X-rays is determined by changing only phi-angle under a fixed psi-angle, and then a distribution of the average stress vs. the penetration depth of X-rays is detected by repeating the similar procedure at different psi-angles. The following conclusions were found out as the result of residual stress measurements on a carbon steel of type S 55 C polished by emery paper. This method is practical enough to use for a plane stress problem. And the assumption of a linear stress gradient adopted in the authors' previous investigations is valid. In case of a triaxial stress analysis, this method is effective for the solution of three shearing stresses. However, three normal stresses can not be solved perfectly except particular psi-angles. (author)

  18. Evaluation of Diversity Antenna Designs Using Ray Tracing, Measured Radiation Patterns, and MIMO Channel Measurements

    Directory of Open Access Journals (Sweden)

    Pal Arindam

    2007-01-01

    Full Text Available This paper presents an evaluation of the MIMO performance of three candidate antenna array designs, each embedded within a PDA footprint, using indoor wideband channel measurements at 5.2 GHz alongside channel simulations. A channel model which employs the plane-wave approximation was used to combine the embedded antenna radiation patterns of the candidate devices obtained from far-field pattern measurements and multipath component parameters from an indoor ray-tracer. The 4-element candidate arrays were each constructed using a different type of antenna element, and despite the diverse element directivities, pattern characteristics, and polarization purities, all three devices were constructed to fully exploit diversity in polarization, space, and angle. Thus, low correlation and high information theoretic capacity was observed in each case. A good match between the model and the measurements is also demonstrated, especially for MIMO subsets of identically or orthogonally polarized linear slot antennas. The interdependencies between the channel XPD, directional spread and pathloss, and the respective impact on channel capacity are also discussed in this paper.

  19. Evaluation of Diversity Antenna Designs Using Ray Tracing, Measured Radiation Patterns, and MIMO Channel Measurements

    Directory of Open Access Journals (Sweden)

    Arindam Pal

    2007-01-01

    Full Text Available This paper presents an evaluation of the MIMO performance of three candidate antenna array designs, each embedded within a PDA footprint, using indoor wideband channel measurements at 5.2 GHz alongside channel simulations. A channel model which employs the plane-wave approximation was used to combine the embedded antenna radiation patterns of the candidate devices obtained from far-field pattern measurements and multipath component parameters from an indoor ray-tracer. The 4-element candidate arrays were each constructed using a different type of antenna element, and despite the diverse element directivities, pattern characteristics, and polarization purities, all three devices were constructed to fully exploit diversity in polarization, space, and angle. Thus, low correlation and high information theoretic capacity was observed in each case. A good match between the model and the measurements is also demonstrated, especially for 2×2 MIMO subsets of identically or orthogonally polarized linear slot antennas. The interdependencies between the channel XPD, directional spread and pathloss, and the respective impact on channel capacity are also discussed in this paper.

  20. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  1. Cole-Cole Measurement of Dispersion Properties for Quality Evaluation of Red Wine

    Science.gov (United States)

    Watanabe, Kota; Taka, Yoshinori; Fujiwara, Osamu

    2009-01-01

    In order to evaluate the quality of red wine, measurement of the complex relative permittivity was conducted in the frequency range from 100 MHz to 40 GHz with a network analyzer. Results showed that the Cole-Cole plot of red wine consists of a semicircle at frequencies above 1 GHz and a straight line at frequencies below 1 GHz, which come from the dispersion properties for the water solution of alcohol and ingredients peculiar to red wine, respectively. Based on the Cole-Cole plots measured for seven kinds of red wines made from the same brand of Merlot in different production years, we estimated Debye dispersion parameters to reveal that the alcohol concentration and ingredient property can simultaneously be evaluated from the parameters for the semicircle and straight line, respectively.

  2. Measurement Uncertainty Evaluation in Dimensional X-ray Computed Tomography Using the Bootstrap Method

    DEFF Research Database (Denmark)

    Hiller, Jochen; Genta, Gianfranco; Barbato, Giulio

    2014-01-01

    measurement processes, e.g., with tactile systems, also due to factors related to systematic errors, mainly caused by specific CT image characteristics. In this paper we propose a simulation-based framework for measurement uncertainty evaluation in dimensional CT using the bootstrap method. In a case study...... the problem concerning measurement uncertainties was addressed with bootstrap and successfully applied to ball-bar CT measurements. Results obtained enabled extension to more complex shapes such as actual industrial components as we show by tests on a hollow cylinder workpiece....

  3. 49 CFR 173.23 - Previously authorized packaging.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Previously authorized packaging. 173.23 Section... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Preparation of Hazardous Materials for Transportation § 173.23 Previously authorized packaging. (a) When the regulations specify a packaging with a specification marking...

  4. Measurement committee of the US cross section evaluation working group. Annual report, 1995

    International Nuclear Information System (INIS)

    Smith, D.L.; McLane, V.

    1995-08-01

    The Cross Section Evaluation Working Group is a long-standing committee charged with the responsibility for organizing and overseeing the U.S. cross-section evaluation effort. It's main product is the official U.S. evaluated nuclear data file, ENDF; the current version of this file is Version VI. All evaluations included in ENDF are reviewed and approved by CSEWG and issued by the U.S. Nuclear Data Center, Brookhaven National Laboratory. CSEWG is comprised of volunteers from the U.S. nuclear data community who possess expertise in evaluation methodologies and who collectively have been responsible for producing most of the evaluations included in ENDF. In 1992 CSEWG added the Measurements Committee to its list of standing committees and subcommittees. This was based on recognition of the importance of experimental data in the evaluation process as well as the realization that measurement activities in the U.S. were declining at an alarming rate. The mission of the Committee is to establish a network of experimentalists in the U.S. which would provide encouragement to the national nuclear data measurement effort through improved communication and facilitation of collaborative activities. The Committee currently has 19 members, and interested scientists are welcome to join the network simply by contacting the Chairman. For reference, the names of the current members and contact information are contained in this report. This annual report is the first such document issued by the Committee. It contains voluntary contributions from 10 laboratories in the U.S. which have been prepared by members of the Committee and submitted to the Chairman for compilation and editing. This report is being distributed in hard copy and is also available on-line via the National Nuclear Data Center, Brookhaven National Laboratory. It is hoped that the information provided here on the work that is going on at the reporting laboratories will prove interesting and stimulating to the readers

  5. The evaluation of the automatic setting of ROI to SPECT measuring cerebral blood flow

    International Nuclear Information System (INIS)

    Mizuno, Hiroshi; Takahashi, Masaaki; Yoshioka, Katsunori

    2007-01-01

    It has been pointed out that the manual settings of region of interest (ROI) to the single-photon-emission-computed-tomography (SPECT) slice lacked objectivity when the fixed quantity value of regional cerebral blood flow (rCBF) was measured previously. Therefore, we jointly developed software Brain ROI'' with Daiichi Radioisotope Laboratories, Ltd. (DRL) that normalized an individual brain to a standard brain template by using Statistical Parametric Mapping 2 (SPM 2) of easy Z-score Imaging System ver. 3.0 (eZIS Ver. 3.0), and, ROI template was set to a specific slice. In this paper, we evaluated the accuracy of this software with ROI template that we made the useful size of the shape, in some clinical samples. As a result, the method of the automatic setting of ROI was the objectively. However, we thought that we should use the shape of ROI template without an influence of Brain atrophy. Moreover, we should see Normalizing individual brain and confirm the accuracy of normalization. When failing in normalization, we should partially correct ROI or set all by the manual operation of the operator. However, it was thought that this software was useful if the tendency was understood because the failure example was few. (author)

  6. Comparison between two different methods for evaluating rumen papillae measures related to different diets.

    Science.gov (United States)

    Scocco, Paola; Brusaferro, Andrea; Catorci, Andrea

    2012-07-01

    Although the Geographical Information System (GIS), which integrates computerized drawing computer assisted design (CAD) and relational databases (data base management system (DBMS)), is best known for applications in geographical and planning cartography, it can also use many kinds of information concerning the territory. A multidisciplinary project was initiated since 5 years a multidisciplinary study was initiated to use GIS to integrate environmental and ecological data with findings on animal health, ethology, and anatomy. This study is chiefly aimed at comparing two different methods for measuring the absorptive surface of rumen papillae. To this scope, 21 female sheep (Ovis aries) on different alimentary regimes (e.g., milk and forage mixed diet, early herbaceous diet, dry hay diet, and fresh hay diet at the maximum of pasture flowering and at the maximum of pasture dryness) were used; after slaughtering, 20 papillae were randomly removed from each sample collected from four indicator regions of rumen wall, placed near a metric reference and digitally photographed. The images were developed with the ArcGIS™ software to calculate the area of rumen papillae by means of GIS and to measure their mid-level width and length to calculate the papillae area as previously performed with a different method. Spatial measurements were analyzed using univariate and multivariate methods. This work demonstrates that the GIS methodology can be efficiently used for measuring the absorptive surface of rumen papillae. In addition, GIS demonstrated to be a rapid, precise, and objective tool when compared with previously used method. Copyright © 2012 Wiley Periodicals, Inc.

  7. Recurrent severe invasive pneumococcal disease in an adult with previously unknown hyposplenia

    DEFF Research Database (Denmark)

    Ballegaard, Vibe C; Schejbel, Lone; Hoffmann, Steen

    2015-01-01

    was found. Despite immunization against S. pneumoniae and measurement of what was interpreted as protective levels of serotype-specific IgG antibodies after vaccination, the patient suffered from a third episode of IPD. CONCLUSIONS: Individuals with predisposing medical conditions or a history of severe......BACKGROUND: The risk of life-threatening and invasive infections with encapsulated bacteria is increased in patients with hyposplenia or asplenia. We report a case of recurrent invasive pneumococcal meningitis in a woman with previous unknown hyposplenia. She was vaccinated after the first episode...... of meningitis and developed sufficient levels of pneumococcal antibodies. The pneumococcal strains isolated were serotype 7 F and 17 F. To our knowledge, there has been no previously reported case of recurrent invasive pneumococcal disease in a pneumococcal vaccinated adult with hyposplenia and apparently...

  8. 22 CFR 40.91 - Certain aliens previously removed.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Certain aliens previously removed. 40.91... IMMIGRANTS UNDER THE IMMIGRATION AND NATIONALITY ACT, AS AMENDED Aliens Previously Removed § 40.91 Certain aliens previously removed. (a) 5-year bar. An alien who has been found inadmissible, whether as a result...

  9. The ambiguities of performance-based governance reforms in Italy: Reviving the fortunes of evaluation and performance measurement.

    Science.gov (United States)

    Marra, Mita

    2018-08-01

    Over the past two decades, Italy's administrative reforms have institutionalized evaluation to improve program effectiveness, staff productivity, and results-driven accountability against waste and corruption. Across ministries, regional governments, universities, schools and environmental protection agencies, seemingly unexpected consequences have emerged out of the implementation of performance measurement and evaluation regimes within public organizations. Formal compliance to legally binding evaluation procedures, judicially-sanctioned managerial accountability and lack of cross-agency coordination coupled with long-standing cultural separations among evaluators are some of the ambiguities associated with a performance-based governance system within Italian public administration. Building upon the 'new governane theory,' and qualitative fieldwork, I explore the political consequences of evaluation and performance measurement for possible improvements. From a normative perspective, greater integration between program evaluation and performance measurement can support organizational learning and democratic accountability both at the central and local level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Evaluation of Uranium Measurements in Water by Various Methods - 13571

    Energy Technology Data Exchange (ETDEWEB)

    Tucker, Brian J. [Shaw Environmental and Infrastructure Group, 150 Royall Street, Canton, MA (United States); Workman, Stephen M. [ALS Laboratory Group, Environmental Division, 225 Commerce Drive, Fort Collins, CO 80524 (United States)

    2013-07-01

    In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will

  11. Evaluation of Uranium Measurements in Water by Various Methods - 13571

    International Nuclear Information System (INIS)

    Tucker, Brian J.; Workman, Stephen M.

    2013-01-01

    In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will

  12. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  13. Quantifying measurement uncertainty and spatial variability in the context of model evaluation

    Science.gov (United States)

    Choukulkar, A.; Brewer, A.; Pichugina, Y. L.; Bonin, T.; Banta, R. M.; Sandberg, S.; Weickmann, A. M.; Djalalova, I.; McCaffrey, K.; Bianco, L.; Wilczak, J. M.; Newman, J. F.; Draxl, C.; Lundquist, J. K.; Wharton, S.; Olson, J.; Kenyon, J.; Marquis, M.

    2017-12-01

    In an effort to improve wind forecasts for the wind energy sector, the Department of Energy and the NOAA funded the second Wind Forecast Improvement Project (WFIP2). As part of the WFIP2 field campaign, a large suite of in-situ and remote sensing instrumentation was deployed to the Columbia River Gorge in Oregon and Washington from October 2015 - March 2017. The array of instrumentation deployed included 915-MHz wind profiling radars, sodars, wind- profiling lidars, and scanning lidars. The role of these instruments was to provide wind measurements at high spatial and temporal resolution for model evaluation and improvement of model physics. To properly determine model errors, the uncertainties in instrument-model comparisons need to be quantified accurately. These uncertainties arise from several factors such as measurement uncertainty, spatial variability, and interpolation of model output to instrument locations, to name a few. In this presentation, we will introduce a formalism to quantify measurement uncertainty and spatial variability. The accuracy of this formalism will be tested using existing datasets such as the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign. Finally, the uncertainties in wind measurement and the spatial variability estimates from the WFIP2 field campaign will be discussed to understand the challenges involved in model evaluation.

  14. MEASURING INSTRUMENT CONSTRUCTION AND VALIDATION IN ESTIMATING UNICYCLING SKILL LEVEL

    Directory of Open Access Journals (Sweden)

    Ivan Granić

    2012-09-01

    Full Text Available Riding the unicycle presupposes the knowledge of the set of elements which describe motoric skill, or just part of that set with which we could measure the level of that knowledge. Testing and evaluation of the elements is time consuming. In order to design a unique, composite measuring instrument, to facilitate the evaluation of the initial level of unicycling skill, we tested 17 recreative subjects who were learning to ride the unicycle in 15 hours of training, without any previous knowledge or experience what was measured before the beginning of the training. At the beginning and at the end of the training they were tested with the set of the 12 riding elements test that was carried out to record only successful attempts, followed by unique SLALOM test which include previously tested elements. It was found that the unique SLALOM test has good metric features and a high regression coefficient showed that the SLALOM could be used instead of the 12 elements of unicycle riding skill, and it could be used as a uniform test to evaluate learned or existing knowledge. Because of its simplicity in terms of action and simultaneous testing of more subjects, the newly constructed test could be used in evaluating the unicycling recreational level, but also for monitoring and programming transformation processes to develop the motor skills of riding of unicycle. Because of its advantages, it is desirable to include unicycling in the educational processes of learning new motor skills, which can be evaluated by the results of this research. The obtained results indicate that the unicycle should be seriously consider as a training equipment to “refresh” or expand the recreational programs, without any fear that it is just for special people. Namely, it was shown that the previously learned motor skills (skiing, roller-skating, and cycling had no effect on the results of final testing.

  15. Evaluation of body condition score measured throughout lactation as an indicator of fertility in dairy cattle

    OpenAIRE

    Banos, G; Brotherstone, S; Coffey, MP

    2004-01-01

    Body condition score (BCS) records of primiparous Holstein cows were analyzed both as a single measure per animal and as repeated measures per sire of cow. The former resulted in a single, average, genetic evaluation for each sire, and the latter resulted in separate genetic evaluations per day of lactation. Repeated measure analysis yielded genetic correlations of less than unity between days of lactation, suggesting that BCS may not be the same trait across lactation. Differences between da...

  16. On the Use of Presence Measurements to Evaluate Computer Games

    DEFF Research Database (Denmark)

    Nordahl, Rolf; Korsgaard, Dannie

    2008-01-01

    As the game industry expresses a growing demand for effective evaluation methods, it is worth investigating if the commonly used questionnaires can be replaced by alternative ways of measuring user experience in interactive environments. This paper describes an experiment where an existing presence...... measurement method is modified for use in computer game development. 39 subjects were part of the experiment, which was designed to test applicability of the adapted presence measuring method. Besides playing a game prototype, test participants were asked to press a button when a visual signal, triggered...... by an in-game event, would appear on the screen in the periphery of sight. Noting how strong the signal was is assumed to infer how strong the stimuli had to be in order to break the immersive presence. The results indicated that the adapted method with observations from the test is more useful, than...

  17. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    Science.gov (United States)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (Pvolume during the isovolume maneuver (standard deviationpulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  18. 45 CFR 2522.540 - Do the costs of performance measurement or evaluation count towards the statutory cap on...

    Science.gov (United States)

    2010-10-01

    ... evaluation count towards the statutory cap on administrative costs? 2522.540 Section 2522.540 Public Welfare... measurement or evaluation count towards the statutory cap on administrative costs? No, the costs of performance measurement and evaluation do not count towards the statutory five percent cap on administrative...

  19. Performance evaluation of the short-time objective intelligibility measure with different band importance functions

    DEFF Research Database (Denmark)

    Heidemann Andersen, Asger; de Haan, Jan Mark; Tan, Zheng-Hua

    performance measures: root-mean-squared-error, Pearson correlation, and Kendall rank correlation. The results show substantially improved performance when fitting and evaluating on the same dataset. However, this advantage does not necessarily subsist when fitting and evaluating on different datasets. When...... with a filter bank, 2) envelopes are extracted from each band, 3) the temporal correlation between clean and degraded envelopes is computed in short time segments, and 4) the correlation is averaged across time and frequency bands to obtain the final output. An unusual choice in the design of the STOI measure...

  20. Actometry in measuring the symptom severity of restless legs syndrome.

    Science.gov (United States)

    Tuisku, K; Holi, M M; Wahlbeck, K; Ahlgren, A J; Lauerma, H

    2005-05-01

    In a previous, controlled study we demonstrated that the general lower limb activity measured by three-channel actometry is a promising objective measure of restless legs syndrome (RLS) severity. In the present study we have further evaluated the method in measuring RLS symptom severity in an open, single-day pramipexole intervention with 15 RLS patients. Both our standardized actometric parameters (nocturnal lower limb activity and controlled rest activity) decreased significantly during the intervention in parallel with the subjectively reported relief of RLS symptoms.

  1. Transgender-inclusive measures of sex/gender for population surveys: Mixed-methods evaluation and recommendations.

    Science.gov (United States)

    Bauer, Greta R; Braimoh, Jessica; Scheim, Ayden I; Dharma, Christoffer

    2017-01-01

    Given that an estimated 0.6% of the U.S. population is transgender (trans) and that large health disparities for this population have been documented, government and research organizations are increasingly expanding measures of sex/gender to be trans inclusive. Options suggested for trans community surveys, such as expansive check-all-that-apply gender identity lists and write-in options that offer maximum flexibility, are generally not appropriate for broad population surveys. These require limited questions and a small number of categories for analysis. Limited evaluation has been undertaken of trans-inclusive population survey measures for sex/gender, including those currently in use. Using an internet survey and follow-up of 311 participants, and cognitive interviews from a maximum-diversity sub-sample (n = 79), we conducted a mixed-methods evaluation of two existing measures: a two-step question developed in the United States and a multidimensional measure developed in Canada. We found very low levels of item missingness, and no indicators of confusion on the part of cisgender (non-trans) participants for both measures. However, a majority of interview participants indicated problems with each question item set. Agreement between the two measures in assessment of gender identity was very high (K = 0.9081), but gender identity was a poor proxy for other dimensions of sex or gender among trans participants. Issues to inform measure development or adaptation that emerged from analysis included dimensions of sex/gender measured, whether non-binary identities were trans, Indigenous and cultural identities, proxy reporting, temporality concerns, and the inability of a single item to provide a valid measure of sex/gender. Based on this evaluation, we recommend that population surveys meant for multi-purpose analysis consider a new Multidimensional Sex/Gender Measure for testing that includes three simple items (one asked only of a small sub-group) to assess gender

  2. Transgender-inclusive measures of sex/gender for population surveys: Mixed-methods evaluation and recommendations.

    Directory of Open Access Journals (Sweden)

    Greta R Bauer

    Full Text Available Given that an estimated 0.6% of the U.S. population is transgender (trans and that large health disparities for this population have been documented, government and research organizations are increasingly expanding measures of sex/gender to be trans inclusive. Options suggested for trans community surveys, such as expansive check-all-that-apply gender identity lists and write-in options that offer maximum flexibility, are generally not appropriate for broad population surveys. These require limited questions and a small number of categories for analysis. Limited evaluation has been undertaken of trans-inclusive population survey measures for sex/gender, including those currently in use. Using an internet survey and follow-up of 311 participants, and cognitive interviews from a maximum-diversity sub-sample (n = 79, we conducted a mixed-methods evaluation of two existing measures: a two-step question developed in the United States and a multidimensional measure developed in Canada. We found very low levels of item missingness, and no indicators of confusion on the part of cisgender (non-trans participants for both measures. However, a majority of interview participants indicated problems with each question item set. Agreement between the two measures in assessment of gender identity was very high (K = 0.9081, but gender identity was a poor proxy for other dimensions of sex or gender among trans participants. Issues to inform measure development or adaptation that emerged from analysis included dimensions of sex/gender measured, whether non-binary identities were trans, Indigenous and cultural identities, proxy reporting, temporality concerns, and the inability of a single item to provide a valid measure of sex/gender. Based on this evaluation, we recommend that population surveys meant for multi-purpose analysis consider a new Multidimensional Sex/Gender Measure for testing that includes three simple items (one asked only of a small sub-group to

  3. Transgender-inclusive measures of sex/gender for population surveys: Mixed-methods evaluation and recommendations

    Science.gov (United States)

    Bauer, Greta R.; Braimoh, Jessica; Scheim, Ayden I.; Dharma, Christoffer

    2017-01-01

    Given that an estimated 0.6% of the U.S. population is transgender (trans) and that large health disparities for this population have been documented, government and research organizations are increasingly expanding measures of sex/gender to be trans inclusive. Options suggested for trans community surveys, such as expansive check-all-that-apply gender identity lists and write-in options that offer maximum flexibility, are generally not appropriate for broad population surveys. These require limited questions and a small number of categories for analysis. Limited evaluation has been undertaken of trans-inclusive population survey measures for sex/gender, including those currently in use. Using an internet survey and follow-up of 311 participants, and cognitive interviews from a maximum-diversity sub-sample (n = 79), we conducted a mixed-methods evaluation of two existing measures: a two-step question developed in the United States and a multidimensional measure developed in Canada. We found very low levels of item missingness, and no indicators of confusion on the part of cisgender (non-trans) participants for both measures. However, a majority of interview participants indicated problems with each question item set. Agreement between the two measures in assessment of gender identity was very high (K = 0.9081), but gender identity was a poor proxy for other dimensions of sex or gender among trans participants. Issues to inform measure development or adaptation that emerged from analysis included dimensions of sex/gender measured, whether non-binary identities were trans, Indigenous and cultural identities, proxy reporting, temporality concerns, and the inability of a single item to provide a valid measure of sex/gender. Based on this evaluation, we recommend that population surveys meant for multi-purpose analysis consider a new Multidimensional Sex/Gender Measure for testing that includes three simple items (one asked only of a small sub-group) to assess gender

  4. The Effects of Survey Timing on Student Evaluation of Teaching Measures Obtained Using Online Surveys

    Science.gov (United States)

    Estelami, Hooman

    2015-01-01

    Teaching evaluations are an important measurement tool used by business schools in gauging the level of student satisfaction with the educational services delivered by faculty. The growing use of online teaching evaluations has enabled educational administrators to expand the time period during which student evaluation of teaching (SET) surveys…

  5. A prospective evaluation of treatment with Selective Internal Radiation Therapy (SIR-spheres) in patients with unresectable liver metastases from colorectal cancer previously treated with 5-FU based chemotherapy

    International Nuclear Information System (INIS)

    Lim, L; Gibbs, P; Yip, D; Shapiro, JD; Dowling, R; Smith, D; Little, A; Bailey, W; Liechtenstein, M

    2005-01-01

    To prospectively evaluate the efficacy and safety of selective internal radiation (SIR) spheres in patients with inoperable liver metastases from colorectal cancer who have failed 5FU based chemotherapy. Patients were prospectively enrolled at three Australian centres. All patients had previously received 5-FU based chemotherapy for metastatic colorectal cancer. Patients were ECOG 0–2 and had liver dominant or liver only disease. Concurrent 5-FU was given at investigator discretion. Thirty patients were treated between January 2002 and March 2004. As of July 2004 the median follow-up is 18.3 months. Median patient age was 61.7 years (range 36 – 77). Twenty-nine patients are evaluable for toxicity and response. There were 10 partial responses (33%), with the median duration of response being 8.3 months (range 2–18) and median time to progression of 5.3 mths. Response rates were lower (21%) and progression free survival shorter (3.9 mths) in patients that had received all standard chemotherapy options (n = 14). No responses were seen in patients with a poor performance status (n = 3) or extrahepatic disease (n = 6). Overall treatment related toxicity was acceptable, however significant late toxicity included 4 cases of gastric ulceration. In patients with metastatic colorectal cancer that have previously received treatment with 5-FU based chemotherapy, treatment with SIR-spheres has demonstrated encouraging activity. Further studies are required to better define the subsets of patients most likely to respond

  6. Evaluation of OiW Measurement Technologies for Deoiling Hydrocyclone Efficiency Estimation and Control

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Pedersen, Simon; Yang, Zhenyu

    2016-01-01

    Offshore oil and gas industry has been active in the North Sea for more than half a century, contributing to the economy and facilitating a low oil import rate in the producing countries. The peak production was reached in the early 2000s, and since then the oil production has been decreasing while...... to reach the desired oil production capacity, consequently the discharged amount of oil increases.This leads to oceanic pollution, which has been linked to various negative effects in the marine life. The current legislation requires a maximum oil discharge of 30 parts per million (PPM). The oil in water...... a novel control technology which is based on online and dynamic OiW measurements. This article evaluates some currently available on- line measuring technologies to measure OiW, and the possibility to use these techniques for hydrocyclone efficiency evaluation, model development and as a feedback...

  7. Trephine Transverse Colostomy Is Effective for Patients Who Have Previously Undergone Rectal Surgery

    Science.gov (United States)

    Yeom, Seung-Seop; Jung, Sung Woo; Oh, Se Heon; Lee, Jong Lyul; Yoon, Yong Sik; Park, In Ja; Lim, Seok-Byung; Yu, Chang Sik; Kim, Jin Cheon

    2018-01-01

    Purpose Colostomy creation is an essential procedure for colorectal surgeons, but the preferred method of colostomy varies by surgeon. We compared the outcomes of trephine colostomy creation with open those for the (laparotomy) and laparoscopic methods and evaluated appropriate indications for a trephine colostomy and the advantages of the technique. Methods We retrospectively evaluated 263 patients who had undergone colostomy creation by trephine, open and laparoscopic approaches between April 2006 and March 2016. We compared the clinical features and the operative and postoperative outcomes according to the approach used for stoma creation. Results One hundred sixty-three patients (62%) underwent colostomy surgery for obstructive causes and 100 (38%) for fistulous problems. The mean operative time was significantly shorter with the trephine approach (trephine, 46.0 ± 1.9 minutes; open, 78.7 ± 3.9 minutes; laparoscopic, 63.5 ± 5.0 minutes; P colostomy was feasible for a diversion colostomy (P colostomy is safe and can be implemented quickly in various situations, and compared to other colostomy procedures, the patient’s recovery is faster. Previous laparotomy history was not a contraindication for a trephine colostomy, and a trephine transverse colostomy is feasible for patients who have undergone previous rectal surgery. PMID:29742862

  8. Evaluation of segmented gamma scanner measurements on cans of recoverable scrap

    International Nuclear Information System (INIS)

    Shull, A.H.; Weber, J.H.; MacMurdo, K.W.; Baker, L.B.

    1991-01-01

    Savannah River Site (SRS) has had a long-standing concern about the inability to measure recoverable scrap. A segmented gamma scanner (SGS) was evaluated for use in measuring cans of scrap materials. Four scrap cans were selected and re-packaged into containers that could be measured using calorimetry and gamma spectrometry. These scrap cans were later used as working standards for the SGS. In addition, replicate measurements were made on all cans of scrap currently stored with estimated values. Before accepting the SGS measurements on the cans, data from the replicate measurements of the standards and a limited number of process cans were analyzed to determine if there was a significant bias between the SGS and the calorimeter-gamma spectrometer measurements, if the random replication error would be acceptable for accountability, to set control limits for the workings standards, and to determine acceptable differences between replicate measurements. After completing the measurement of all process scrap cans in the inventory, the the final data were analyzed and estimates based on the two sets of data compared. The methodology used to determine the appropriate measurement error model, to estimate the measurement errors, to set control limits, and to determine the significance of the bias will be described as well as a comparison of the error estimates based on the preliminary versus final data

  9. Six weeks of aerobic dance exercise improves blood oxidative stress status and increases interleukin-2 in previously sedentary women.

    Science.gov (United States)

    Leelarungrayub, Donrawee; Saidee, Kunteera; Pothongsunun, Prapas; Pratanaphon, Sainetee; YanKai, Araya; Bloomer, Richard J

    2011-07-01

    This study evaluated the change in blood oxidative stress, blood interleukin-2, and physical performance following 6 weeks of moderate intensity and duration aerobic dance exercise in 24 sedentary women. Blood samples were collected at rest twice before (baseline) and after the 6-week intervention for analysis of protein hydroperoxide (PrOOH), malondialdehyde (MDA), total anti-oxidant capacity (TAC), and interleukin-2 (IL-2) levels. Maximal treadmill run time (Time(max)) and maximal oxygen consumption (VO(2max)) were also measured. All variables were statistically analyzed with a repeated measurement ANOVA and Tukey post hoc. No differences were noted in any variable during the baseline period (p > 0.05). After aerobic dance exercise, VO(2max), Time(max), TAC and IL-2 were significantly increased, whereas MDA levels were decreased significantly (p exercise. It can be concluded that aerobic dance exercise at a moderate intensity and duration can improve physical fitness, decrease MDA, and increase TAC and IL-2 in previously sedentary women. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pglaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  11. Evaluation of disorder predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan

    2011-01-01

    Lack of stable three-dimensional structure, or intrinsic disorder, is a common phenomenon in proteins. Naturally, unstructured regions are proven to be essential for carrying function by many proteins, and therefore identification of such regions is an important issue. CASP has been assessing the state of the art in predicting disorder regions from amino acid sequence since 2002. Here, we present the results of the evaluation of the disorder predictions submitted to CASP9. The assessment is based on the evaluation measures and procedures used in previous CASPs. The balanced accuracy and the Matthews correlation coefficient were chosen as basic measures for evaluating the correctness of binary classifications. The area under the receiver operating characteristic curve was the measure of choice for evaluating probability-based predictions of disorder. The CASP9 methods are shown to perform slightly better than the CASP7 methods but not better than the methods in CASP8. It was also shown that capability of most CASP9 methods to predict disorder decreases with increasing minimum disorder segment length.

  12. The relationship between emotional intelligence, previous caring experience and mindfulness in student nurses and midwives: a cross sectional analysis.

    Science.gov (United States)

    Snowden, Austyn; Stenhouse, Rosie; Young, Jenny; Carver, Hannah; Carver, Fiona; Brown, Norrie

    2015-01-01

    Emotional Intelligence (EI), previous caring experience and mindfulness training may have a positive impact on nurse education. More evidence is needed to support the use of these variables in nurse recruitment and retention. To explore the relationship between EI, gender, age, programme of study, previous caring experience and mindfulness training. Cross sectional element of longitudinal study. 938year one nursing, midwifery and computing students at two Scottish Higher Education Institutes (HEIs) who entered their programme in September 2013. Participants completed a measure of 'trait' EI: Trait Emotional Intelligence Questionnaire Short Form (TEIQue-SF); and 'ability' EI: Schutte's et al. (1998) Emotional Intelligence Scale (SEIS). Demographics, previous caring experience and previous training in mindfulness were recorded. Relationships between variables were tested using non-parametric tests. Emotional intelligence increased with age on both measures of EI [TEIQ-SF H(5)=15.157 p=0.001; SEIS H(5)=11.388, p=0.044]. Females (n=786) scored higher than males (n=149) on both measures [TEIQ-SF, U=44,931, z=-4.509, pemotional intelligence. Mindfulness training was associated with higher 'ability' emotional intelligence. Implications for recruitment, retention and further research are explored. Copyright © 2014. Published by Elsevier Ltd.

  13. Evaluation of the Relationship between Literacy and Mathematics Skills as Assessed by Curriculum-Based Measures

    Science.gov (United States)

    Rutherford-Becker, Kristy J.; Vanderwood, Michael L.

    2009-01-01

    The purpose of this study was to evaluate the extent that reading performance (as measured by curriculum-based measures [CBM] of oral reading fluency [ORF] and Maze reading comprehension), is related to math performance (as measured by CBM math computation and applied math). Additionally, this study examined which of the two reading measures was a…

  14. Evaluation of turbulence measurement techniques from a single Doppler lidar

    Directory of Open Access Journals (Sweden)

    T. A. Bonin

    2017-08-01

    Full Text Available Measurements of turbulence are essential to understand and quantify the transport and dispersal of heat, moisture, momentum, and trace gases within the planetary boundary layer (PBL. Through the years, various techniques to measure turbulence using Doppler lidar observations have been proposed. However, the accuracy of these measurements has rarely been validated against trusted in situ instrumentation. Herein, data from the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA are used to verify Doppler lidar turbulence profiles through comparison with sonic anemometer measurements. For 17 days at the end of the experiment, a single scanning Doppler lidar continuously cycled through different turbulence measurement strategies: velocity–azimuth display (VAD, six-beam scans, and range–height indicators (RHIs with a vertical stare.Measurements of turbulence kinetic energy (TKE, turbulence intensity, and stress velocity from these techniques are compared with sonic anemometer measurements at six heights on a 300 m tower. The six-beam technique is found to generally measure turbulence kinetic energy and turbulence intensity the most accurately at all heights (r2  ≈  0.78, showing little bias in its observations (slope of  ≈  0. 95. Turbulence measurements from the velocity–azimuth display method tended to be biased low near the surface, as large eddies were not captured by the scan. None of the methods evaluated were able to consistently accurately measure the shear velocity (r2 =  0.15–0.17. Each of the scanning strategies assessed had its own strengths and limitations that need to be considered when selecting the method used in future experiments.

  15. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  16. Measuring mental health in the clinical setting: what is important to service users? The Mini-Service user Recovery Evaluation scale (Mini-SeRvE).

    Science.gov (United States)

    Barber, Joanna M; Parsons, Helen; Wilson, Carol A; Cook, Christopher C H

    2017-12-01

    Since 2001, a policy of positive mental health recovery has been promoted in the UK, with service user involvement. This has not been easy to implement in the clinical setting. To develop and validate a brief self-report, service user-designed, outcome measure (Mini-SeRvE), for clinical use, including spiritual and religious issues. From the previously developed Service user Recovery Evaluation scale (SeRvE), 15 questions were selected for Mini-SeRvE which was self-completed by 207 people; 100 service users and, for comparison, 107 staff. Results were analysed using SPSS software (SPSS Inc., Chicago, IL). Mini-SeRvE is reliable, Cronbach's alpha 0.852. Correlation with another recovery scale, Mental Health Recovery Measure, was high, r = 0.819. Three reliable subscales emerged; existential well-being (EWB), mental ill-being (MIB) and religious well-being (RWB). Scores of the EWB and MIB subscales were higher for staff, consistent with higher mental well-being. Religious well-being scores were higher in service users, who also rated religion as more important to them. Mini-SeRvE is a valid measure of service user recovery. The importance of religion/spiritual belief for our users is highlighted, this being reflected in the subject matter of Mini-SeRvE. Mini-SeRvE assessments could show individual priorities, evaluate therapy and aid clinical decision-making.

  17. Self-informant Agreement for Personality and Evaluative Person Descriptors: Comparing Methods for Creating Informant Measures.

    Science.gov (United States)

    Simms, Leonard J; Zelazny, Kerry; Yam, Wern How; Gros, Daniel F

    2010-05-01

    Little attention typically is paid to the way self-report measures are translated for use in self-informant agreement studies. We studied two possible methods for creating informant measures: (a) the traditional method in which self-report items were translated from the first- to the third-person and (b) an alternative meta-perceptual method in which informants were directed to rate their perception of the targets' self-perception. We hypothesized that the latter method would yield stronger self-informant agreement for evaluative personality dimensions measured by indirect item markers. We studied these methods in a sample of 303 undergraduate friendship dyads. Results revealed mean-level differences between methods, similar self-informant agreement across methods, stronger agreement for Big Five dimensions than for evaluative dimensions, and incremental validity for meta-perceptual informant rating methods. Limited power reduced the interpretability of several sparse acquaintanceship effects. We conclude that traditional informant methods are appropriate for most personality traits, but meta-perceptual methods may be more appropriate when personality questionnaire items reflect indirect indicators of the trait being measured, which is particularly likely for evaluative traits.

  18. Measurement and Evaluation of Finger Tapping Movements Using Log-linearized Gaussian Mixture Networks

    Directory of Open Access Journals (Sweden)

    Masaru Yokoe

    2009-03-01

    Full Text Available This paper proposes a method to quantitatively measure and evaluate finger tapping movements for the assessment of motor function using log-linearized Gaussian mixture networks (LLGMNs. First, finger tapping movements are measured using magnetic sensors, and eleven indices are computed for evaluation. After standardizing these indices based on those of normal subjects, they are input to LLGMNs to assess motor function. Then, motor ability is probabilistically discriminated to determine whether it is normal or not using a classifier combined with the output of multiple LLGMNs based on bagging and entropy. This paper reports on evaluation and discrimination experiments performed on finger tapping movements in 33 Parkinson’s disease (PD patients and 32 normal elderly subjects. The results showed that the patients could be classified correctly in terms of their impairment status with a high degree of accuracy (average rate: 93:1 § 3:69% using 12 LLGMNs, which was about 5% higher than the results obtained using a single LLGMN.

  19. Evaluating probability measures related to subsurface flow and transport

    International Nuclear Information System (INIS)

    Cawlfield, J.D.

    1991-01-01

    Probabilistic modeling approaches are being used increasingly in order to carry out quantified risk analysis and to evaluate the uncertainty existing in subsurface flow and transport analyses. The work presented in this paper addresses three issues: comparison of common probabilistic modeling techniques, recent results regarding the sensitivity of probability measures to likely changes in the uncertain variables for transport in porous media, and a discussion of some questions regarding fundamental modeling philosophy within a probabilistic framework. Recent results indicate that uncertainty regarding average flow velocity controls the probabilistic outcome, while uncertainty in the dispersivity and diffusion coefficient does not seem very important. Uncertainty of reaction terms is important only at early times in the transport process. Questions are posed regarding (1) the inclusion of macrodispersion in a probabilistic analysis, (2) statistics of flow velocity and (3) the notion of an ultimate probability measure for subsurface flow analyses

  20. Burn-up measurements coupling gamma spectrometry and neutron measurement

    Energy Technology Data Exchange (ETDEWEB)

    Toubon, H.; Pin, P. [AREVA/CANBERRA, 1 rue des Herons, 78182 St Quentin-en-Yvelines Cedex (France); Lebrun, A. [IAEA, Wagramer Strasse 5, PO Box 100, Vienna (Austria); Oriol, L.; Saurel, N. [CEA Cadarache, 13108 Saint Paul Lez Durance Cedex (France); Gain, T. [AREVA/COGEMA Reprocessing Business Unit, La Hague, 50444 Beaumont Hague Cedex (France)

    2006-07-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  1. Burn-up measurements coupling gamma spectrometry and neutron measurement

    International Nuclear Information System (INIS)

    Toubon, H.; Pin, P.; Lebrun, A.; Oriol, L.; Saurel, N.; Gain, T.

    2006-01-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  2. Evaluation on the measurements of Grids for PWR's Spent Fuel in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yong Sun; Kim, Gil Soo; Kim, Young Joon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    4 grids were successfully measured to get cell sizes of grids which were burned about 3 cycles in the core of a reactor. In general, to minimize the standard deviation to the mean, a grid is to be set on the fixing jig for maintaining the stable position by master-slave manipulators mounted on the hot cell wall of M5a. The data were collected in MS-Excel sheet, calculated by VBA (visual basic for application) program, and analyzed. The analyzed data were observed a little shifted to both left and right sides as well as both top and bottom sides from the center of a grid. The results were also evaluated by conventional statistics analysis to understand the dimensional properties as well as integrities of grids. The developed 3-dimensional measurement apparatus was applied to measure the cell sizes of four grids, and the acquired data were also evaluated by conventional statistics analysis. As a result, the evaluated data seems to be very close to the mean of population, but they show a peculiarity which is to be studied the reason.

  3. Experimental evaluation of a polycrystal deformation modeling scheme using neutron diffraction measurements

    DEFF Research Database (Denmark)

    Clausen, Bjørn; Lorentzen, Torben

    1997-01-01

    The uniaxial behavior of aluminum polycrystals is simulated using a rate-independent incremental self-consistent elastic-plastic polycrystal deformation model, and the results are evaluated by neutron diffraction measurements. The elastic strains deduced from the model show good agreement...

  4. Psychometric evaluation of the internalized stigma of mental illness scale for patients with mental illnesses: measurement invariance across time.

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Chang

    Full Text Available BACKGROUND: The current investigation examined the psychometric properties of the Internalized Stigma of Mental Illness (ISMI scale in a sample of patients with mental illness. In addition to the internal consistency, test-retest reliability, and concurrent validity that previous studies have tested for the ISMI, we extended the evaluation to its construct validity and measurement invariance using confirmatory factor analysis (CFA. METHODS: Three hundred forty-seven participants completed two questionnaires (i.e., the ISMI and the Depression and Somatic Symptoms Scale [DSSS], and 162 filled out the ISMI again after 50.23±31.18 days. RESULTS: The results of this study confirmed the frame structure of the ISMI; however, the Stigma Resistance subscale in the ISMI seemed weak. In addition, internal consistency, test-retest reliability, and concurrent validity were all satisfactory for all subscales and the total score of the ISMI, except for Stigma Resistance (α = 0.66; ICC = 0.52, and r = 0.02 to 0.06 with DSSS. Therefore, we hypothesize that Stigma Resistance is a new concept rather than a concept in internalized stigma. The acceptable fit indices supported the measurement invariance of the ISMI across time, and suggested that people with mental illness interpret the ISMI items the same at different times. CONCLUSION: The clinical implication of our finding is that clinicians, when they design interventions, may want to use the valid and reliable ISMI without the Stigma Resistance subscale to evaluate the internalized stigma of people with mental illness.

  5. A signal detection-item response theory model for evaluating neuropsychological measures.

    Science.gov (United States)

    Thomas, Michael L; Brown, Gregory G; Gur, Ruben C; Moore, Tyler M; Patt, Virginie M; Risbrough, Victoria B; Baker, Dewleen G

    2018-02-05

    Models from signal detection theory are commonly used to score neuropsychological test data, especially tests of recognition memory. Here we show that certain item response theory models can be formulated as signal detection theory models, thus linking two complementary but distinct methodologies. We then use the approach to evaluate the validity (construct representation) of commonly used research measures, demonstrate the impact of conditional error on neuropsychological outcomes, and evaluate measurement bias. Signal detection-item response theory (SD-IRT) models were fitted to recognition memory data for words, faces, and objects. The sample consisted of U.S. Infantry Marines and Navy Corpsmen participating in the Marine Resiliency Study. Data comprised item responses to the Penn Face Memory Test (PFMT; N = 1,338), Penn Word Memory Test (PWMT; N = 1,331), and Visual Object Learning Test (VOLT; N = 1,249), and self-report of past head injury with loss of consciousness. SD-IRT models adequately fitted recognition memory item data across all modalities. Error varied systematically with ability estimates, and distributions of residuals from the regression of memory discrimination onto self-report of past head injury were positively skewed towards regions of larger measurement error. Analyses of differential item functioning revealed little evidence of systematic bias by level of education. SD-IRT models benefit from the measurement rigor of item response theory-which permits the modeling of item difficulty and examinee ability-and from signal detection theory-which provides an interpretive framework encompassing the experimentally validated constructs of memory discrimination and response bias. We used this approach to validate the construct representation of commonly used research measures and to demonstrate how nonoptimized item parameters can lead to erroneous conclusions when interpreting neuropsychological test data. Future work might include the

  6. Fiscal 1999 technological survey report. Part 2. Applied technology for measuring human sense (Human sense measuring manual - basic technology for sense evaluation); Ningen kankaku keisoku manual. 2. Kankaku hyoka kiban gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A method of measuring/evaluating a mental and physical state by means of physiological information developed by a project was compiled into a 'guide book', as was a method of evaluating adaptability to the environment or products; and, this manual was prepared for the purpose of improving the adaptability of human beings to products by making use of the guide book widely in the field of industrial manufacturing. The part 2 explains a hard measuring instrument, evaluation device, simulation system, method of data analysis, etc., as 'basic technology for sense evaluation'. The chapter 1 is a new measuring and evaluation device (device for measuring physiological signals on the surface of the body, device for measuring visual characteristics, measuring device of in vivo substance, measuring device of thermal response, and system for evaluating adaptability of practical form), the chapter 2 is a new simulator (model of human body temperature with clothes on, human comfort meter, perspiring thermal manikin, and autonomic nerve control model in cardiac blood vessel/respiratory system), and the chapter 3 is new experimental/analytical method (new data analysis method and subjective evaluation questionnaire for stress assessment). (NEDO)

  7. Improved evaluation of the coronary collateral circulation measuring the regional blood flow with 133Xe

    International Nuclear Information System (INIS)

    Franz, N.; Strangfeld, D.; Romaniuk, P.; Heublein, B.

    1988-01-01

    In 40 patients with angina pectoris catheter diagnostic measurements of the myocardial flow were carried out after intracoronary application of 133 Xe at rest and after oral application of Curantyl in order to obtain a better evaluation of coronary collaterals. The results show relations between angiographically detected coronary collaterals and the reduced coronary reserve. A quantitative measurement of collaterals from the angiogram facilitates a more precise evaluation of the relation between coronary sclerosis and myocardial flow. (author)

  8. Economic evaluation of occupational safety preventive measures in a hospital.

    Science.gov (United States)

    Ramos, Delfina G; Arezes, Pedro M; Afonso, Paulo

    2015-01-01

    When an organization performs an integrated analysis of risks through its Occupational Health and Safety Management System, several steps are suggested to address the implications of the identified risks. Namely, the organization should make a detailed analysis of the monetary impact for the organization of each of the preventive measures considered. However, it is also important to perform an analysis of the impact of each measure on society (externalities). The aim of this paper is to present a case study related to the application of the proposed economic evaluation methodology. An analysis of the work accidents in a hospital has been made. Three of the major types of accidents have been selected: needle stings, falls and excessive strain. Following the risk assessment, some preventive measures have been designed. Subsequently, the Benefit/Cost ratio (B/C) of these measures has been calculated, both in financial terms (from the organization's perspective) and in economic terms (including the benefits for the worker and for the Society). While the financial ratio is only advantageous in some cases, when the externalities are taken into account, the B/C ratio increases significantly. It is important to consider external benefits to make decisions concerning the implementation of preventive measures in Occupational Health and Safety projects.

  9. Extrapolation techniques evaluating 24 hours of average electromagnetic field emitted by radio base station installations: spectrum analyzer measurements of LTE and UMTS signals

    International Nuclear Information System (INIS)

    Mossetti, Stefano; Bartolo, Daniela de; Nava, Elisa; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina

    2017-01-01

    International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. (authors)

  10. Evaluation of passive methods for measuring ozone in the European Alps

    Energy Technology Data Exchange (ETDEWEB)

    Hangartner, M. [Inst. of Applied Ergonomics and Hygiene, Zurich (Switzerland); Kirchner, M. [GSF Research Centre for Environment and Human Health, Neuherberg (Germany); Werner, H. [Munich Univ. (Germany). Inst. for Bioclimatology and Environmental Research

    1995-12-31

    Under the leadership of the GSF research centre, various research groups were invited to make their ozone and nitrogen oxide collection systems available for comparative testing. It was considered valuable to include not only well developed systems but also methods still under development. For the main comparative test 11 working groups with differing methods took part. Essentially the goal was to evaluate of the integrating ozone measuring methods as compared to continual ozone monitoring methods under field conditions. For this the various collection systems at 6 alpine continual measuring stations in Italy and Bavaria characterising different location types, were compared over 22 weeks

  11. In vitro fertilization outcome in women with endometriosis & previous ovarian surgery

    Directory of Open Access Journals (Sweden)

    Sonja Pop-Trajkovic

    2014-01-01

    Full Text Available Background & objectives: Women with endometriosis often need in vitro fertilization (IVF to concieve. There are conflicting data on the results of IVF in patients with endometriosis. This study was undertaken to elucidate the influence of endometriosis on IVF outcome to give the best counselling for infertile patient with this problem. Methods: The outcome measures in 78 patients with surgically confirmed endometriosis were compared with 157 patients with tubal factor infertility, all of whom have undergone IVF. The groups were matched for age and follicle stimulating hormone (FSH levels. Outcome measures included number of follicles, number of ocytes, peak oestradiol (E2 concentrations and mean number of ampoules of gonadotropins. Cumulative pregnancy, miscarriage and live birth rates were calculated in both the groups. Results: Higher cancelation rates, higher total gonadotropin requirements, lower peak E2 levels and lower oocyte yield were found in women with endometriosis and previous surgery compared with those with tubal factor infertility. However, no differences were found in fertilization, implantation, pregnancy, miscarriage, multiple births and delivery rates between the endometriosis and tubal factor infertility groups. Interpretation & conclusions: The present findings showed that women with endometriosis and previous surgery responded less well to gonadotropins during ovarian stimulation and hence the cost of treatment to achieve pregnancy was higher in this group compared with those with tubal factor infertility. However, the outcome of IVF treatment in patients with endometriosis was as good as in women with tubal factor infertility.

  12. Unexpected but Most Welcome: Mixed Methods for the Validation and Revision of the Participatory Evaluation Measurement Instrument

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve

    2014-01-01

    Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…

  13. Evaluation of different doses of gamma radiation on conservation of the physicochemical and sensorial characteristics of previously fried potatoes

    International Nuclear Information System (INIS)

    Amaral, Frederico Scarin do; Sanches, Maria Angelica Santos Fernandes; Arthur, Valter

    2007-01-01

    The goal of this work was to study the effect of different doses of gamma radiation on the physicochemical and sensorial characteristics of previously fried potatoes, conserved under temperature of refrigeration from 7 to 10 deg C. The irradiation process aims to discharge the refrigeration that increases the cost of the product and the useful life and decreases the microbial load. The previously fried potatoes were in the commerce of Piracicaba City and led to CENA - a laboratory of Food Irradiation. The potatoes were defrosted and stored in plastic packages and irradiated. They were irradiated in a Cobalto-60 source type Gammacell-220 (dose rate of 698 Gy/hour), with doses of 2,0 kGy, 4,0 kGy and 6,0 kGy. The loss of fresh weight was analyzed as well as smell and color (factors L, a, b), after 1, 4 and 6 days of radiation. The experimental delineation used was entirely at random with six repetitions. The irradiated previously fried potatoes presented more significant variations in relation to those not irradiated in relation to their color and smell. The potatoes were darkened and there was alteration of smell (rancidity) more intense in the samples with doses of irradiation of 4,0 and 6,0 kGy. The smell alteration caused by the irradiation of 4,0 and 6,0 kGy. The smell alteration caused by the irradiation happens because of the state of rancidity of the oil used in the previous-fried process. In the sample of 2,0 kGy there was no alteration of color and smell. The colorimetric rates: L, a, b, did not present statistically - coherent results. However it was visually noted in the irradiated samples with doses of 4,0 and 6,0 kGy the loss of the characteristic coloration of the previously fried potato, predominating an opaque color (gray) because of the degradation of pigments (betacarotenoids, etc). It is also an consequence of the irradiation. By analyzing the results it was concluded that the irradiated sample with doses of 2,0 kGy was the sample that maintained

  14. Evaluation of different doses of gamma radiation on conservation of the physicochemical and sensorial characteristics of previously fried potatoes

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Frederico Scarin do; Sanches, Maria Angelica Santos Fernandes [Fundacao Educacional de Fernandopolis FEF-SP, Fernandopolis, SP (Brazil)]. E-mails: maengal@yahoo.com.br; frescarin@yahoo.com.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura CENA, Piracicaba, SP (Brazil). Lab. de Irradiacao de Alimentos e Radioentomologia]. E-mail: arthur@cena.usp.br

    2007-07-01

    The goal of this work was to study the effect of different doses of gamma radiation on the physicochemical and sensorial characteristics of previously fried potatoes, conserved under temperature of refrigeration from 7 to 10 deg C. The irradiation process aims to discharge the refrigeration that increases the cost of the product and the useful life and decreases the microbial load. The previously fried potatoes were in the commerce of Piracicaba City and led to CENA - a laboratory of Food Irradiation. The potatoes were defrosted and stored in plastic packages and irradiated. They were irradiated in a Cobalto-60 source type Gammacell-220 (dose rate of 698 Gy/hour), with doses of 2,0 kGy, 4,0 kGy and 6,0 kGy. The loss of fresh weight was analyzed as well as smell and color (factors L, a, b), after 1, 4 and 6 days of radiation. The experimental delineation used was entirely at random with six repetitions. The irradiated previously fried potatoes presented more significant variations in relation to those not irradiated in relation to their color and smell. The potatoes were darkened and there was alteration of smell (rancidity) more intense in the samples with doses of irradiation of 4,0 and 6,0 kGy. The smell alteration caused by the irradiation of 4,0 and 6,0 kGy. The smell alteration caused by the irradiation happens because of the state of rancidity of the oil used in the previous-fried process. In the sample of 2,0 kGy there was no alteration of color and smell. The colorimetric rates: L, a, b, did not present statistically - coherent results. However it was visually noted in the irradiated samples with doses of 4,0 and 6,0 kGy the loss of the characteristic coloration of the previously fried potato, predominating an opaque color (gray) because of the degradation of pigments (betacarotenoids, etc). It is also an consequence of the irradiation. By analyzing the results it was concluded that the irradiated sample with doses of 2,0 kGy was the sample that maintained

  15. Study on the measurements and evaluation of environmental external exposure after a nuclear accident

    International Nuclear Information System (INIS)

    Sakamoto, R.; Saito, K.; Tsutsumi, M.

    2001-01-01

    Several important issues which affect external exposure in contaminated Chernobyl areas have been investigated using field measurements and computational simulations since 1992. The objectives of the study were: 1) the development of a mobile survey method to collect radiation data over the contaminated wide areas in a shot time; 2) the verification of a method to infer external dose to the population; 3) the provision of basic data used for evaluation of external dose due to gamma ray using a Monte Carlo simulation method. To develop a method to rapidly measure radiation over wide areas and map the extend of fallout, a mobile survey system was constructed and tested; the conversion factors to convert the measured data to required quantities were examined; and finally a detailed contamination map was created. The field surveys were implemented by using a land rover and a helicopter. To infer external dose to inhabitants, radiation measurements were carried out in the living environments using accurate dose meters in addition to individual dose measurements using glass dosimeters. Individual doses were inferred from occupancy factors and dose rate data measured with portable dose rate meters in and around houses. The evaluated doses were compared to directly measured individual doses with glass dosimeters in the seven settlements. A good agreement was observed with an error margin of approximate 20%. Basic data used for the evaluation of environmental gamma-ray dose rate were calculated using a Monte Carlo method. The following two kinds of data have been provided from the calculation: a) conversion factors from the nuclide concentration in the ground to the air kerma rate at 1 m height; and b) shielding factors of a typical Chernobyl house for gamma radiation. (M. Suetake)

  16. An evaluation method of cross-type H-coil angle for accurate two-dimensional vector magnetic measurement

    International Nuclear Information System (INIS)

    Maeda, Yoshitaka; Todaka, Takashi; Shimoji, Hiroyasu; Enokizono, Masato; Sievert, Johanes

    2006-01-01

    Recently, two-dimensional vector magnetic measurement has become popular and many researchers concerned with this field have attracted to develop more accurate measuring systems and standard measurement systems. Because the two-dimensional vector magnetic property is the relationship between the magnetic flux density vector B and the magnetic field strength vector H , the most important parameter is those components. For the accurate measurement of the field strength vector, we have developed an evaluation apparatus, which consists of a standard solenoid coil and a high-precision turntable. Angle errors of a double H-coil (a cross-type H-coil), which is wound one after the other around a former, can be evaluated with this apparatus. The magnetic field strength is compensated with the measured angle error

  17. Self-Evaluation of PANDA-FBG Based Sensing System for Dynamic Distributed Strain and Temperature Measurement.

    Science.gov (United States)

    Zhu, Mengshi; Murayama, Hideaki; Wada, Daichi

    2017-10-12

    A novel method is introduced in this work for effectively evaluating the performance of the PANDA type polarization-maintaining fiber Bragg grating (PANDA-FBG) distributed dynamic strain and temperature sensing system. Conventionally, the errors during the measurement are unknown or evaluated by using other sensors such as strain gauge and thermocouples. This will make the sensing system complicated and decrease the efficiency since more than one kind of sensor is applied for the same measurand. In this study, we used the approximately constant ratio of primary errors in strain and temperature measurement and realized the self-evaluation of the sensing system, which can significantly enhance the applicability, as well as the reliability in strategy making.

  18. Air contamination measurements for the evaluation of internal dose to workers in nuclear medicine departments

    Science.gov (United States)

    De Massimi, B.; Bianchini, D.; Sarnelli, A.; D'Errico, V.; Marcocci, F.; Mezzenga, E.; Mostacci, D.

    2017-11-01

    Radionuclides handled in nuclear medicine departments are often characterized by high volatility and short half-life. It is generally difficult to monitor directly the intake of these short-lived radionuclides in hospital staff: this makes measuring air contamination of utmost interest. The aim of the present work is to provide a method for the evaluation of internal doses to workers in nuclear medicine, by means of an air activity sampling detector, to ensure that the limits prescribed by the relevant legislation are respected. A continuous air sampling system measures isotope concentration with a Nal(TI) detector. Energy efficiency of the system was assessed with GEANT4 and with known activities of 18F. Air is sampled in a number of areas of the nuclear medicine department of the IRST-IRCCS hospital (Meldola- Italy). To evaluate committed doses to hospital staff involved (doctors, technicians, nurses) different exposure situations (rooms, times, radionuclides etc) were considered. After estimating the intake, the committed effective dose has been evaluated, for the different radionuclides, using the dose coefficients mandated by the Italian legislation. Error propagation for the estimated intake and personal dose has been evaluated, starting from measurement statistics.

  19. Measuring Safeguards Culture

    Energy Technology Data Exchange (ETDEWEB)

    Frazar, Sarah L.; Mladineo, Stephen V.

    2011-07-19

    As the International Atomic Energy Agency (IAEA) implements a State Level Approach to its safeguards verification responsibilities, a number of countries are beginning new nuclear power programs and building new nuclear fuel cycle faculties. The State Level approach is holistic and investigatory in nature, creating a need for transparent, non-discriminatory judgments about a state's nonproliferation posture. In support of this need, the authors previously explored the value of defining and measuring a state's safeguards culture. We argued that a clear definition of safeguards culture and an accompanying set of metrics could be applied to provide an objective evaluation and demonstration of a country's nonproliferation posture. As part of this research, we outlined four high-level metrics that could be used to evaluate a state's nuclear posture. We identified general data points. This paper elaborates on those metrics, further refining the data points to generate a measurable scale of safeguards cultures. We believe that this work could advance the IAEA's goals of implementing a safeguards system that is fully information driven, while strengthening confidence in its safeguards conclusions.

  20. An evaluation of passive methods for measurement of radon in dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Lind, B.; Kolstad, A.K.

    1989-01-01

    During the last ten years, different methods have been developed for the measurement of radon in indoor air. In this report the different methods in use by private firms in Norway have been compared. The results of the study show that the methods are quite different in regard to integration time, detection limit and reliability in measurements of radon in indoor air. In 1988 the National Institute of Radiation Hygiene gave directives on the performance of such measurements. In these directives, minimum limits have been set for integration time (7 days) for methods to be used in evaluations of remedial actions. In this report the results from a simple, anonymeous reliability test are reported. The test covered the private firms offering radon meassurement services in Norway. The frequently reported weaknesses by the charcoal method were confirmed in the study. The directives on radon measurements in dwellings are presented. 73 refs.; 11 figs.; 5 tabs

  1. Evaluation of consumer monitors to measure particulate matter.

    Science.gov (United States)

    Sousan, Sinan; Koehler, Kirsten; Hallett, Laura; Peters, Thomas M

    2017-05-01

    Recently, inexpensive (consumer aerosol monitors (CAMs) targeted for use in homes have become available. We evaluated the accuracy, bias, and precision of three CAMs (Foobot from Airoxlab, Speck from Carnegie Mellon University, and AirBeam from HabitatMap) for measuring mass concentrations in occupational settings. In a laboratory study, PM 2.5 measured with the CAMs and a medium-cost aerosol photometer (personal DataRAM 1500, Thermo Scientific) were compared to that from reference instruments for three aerosols (salt, welding fume, and Arizona road dust, ARD) at concentrations up to 8500 μg/m 3 . Three of each type of CAM were included to estimate precision. Compared to reference instruments, mass concentrations measured with the Foobot (r-value = 0.99) and medium-cost photometer (r-value = 0.99) show strong correlation, whereas those from the Speck (r-value range 0.88 - 0.99) and AirBeam (0.7 - 0.96) were less correlated. The Foobot bias was (-12%) for ARD and measurements were similar to the medium-cost instrument. Foobot bias was (< -46%) for salt and welding fume aerosols. Speck bias was at 18% salt for ARD and -86% for welding fume. AirBeam bias was (-36%) for salt and (-83%) for welding fume. All three photometers had a bias (< -82%) for welding fume. Precision was excellent for the Foobot (coefficient of variation range: 5% to 8%) and AirBeam (2% to 9%), but poorer for the Speck (8% to 25%). These findings suggest that the Foobot, with a linear response to different aerosol types and good precision, can provide reasonable estimates of PM 2.5 in the workplace after site-specific calibration to account for particle size and composition.

  2. Measuring IC following a semi-qualitative approach: An integrated framework

    Directory of Open Access Journals (Sweden)

    Chiara Verbano

    2013-09-01

    Full Text Available Purpose: Considering the different IC measures adopted in literature, the advantages of adopting semi-qualitative measures, and the lack of an agreed system for IC evaluation, the purpose of the paper is to analyse literature on IC measurement following a semi-qualitative approach, with the final intent to build an IC measurement framework. Design/methodology/approach: A literature review on IC measurement system, following a semi-qualitative approach, has been conducted and analysed, in order to re-organize and synthesize all items used in previous researches. Findings: An integrated framework emerged from this research and it constitutes an IC  measurement system, created gathering and integrating different items previously adopted in literature. Each of these variables has been organized in categories belonging to one of the three main components of IC: human capital, internal structural capital and relational capital. Originality/value: This research provides an integrated tool for IC evaluation, fostering toward a well agreed measurement system that is still lacking in literature. This framework could be interesting  not only for the academic world, which in the last two decades reveals increasing attention to IC, but also for the management of the companies, that with IC measurement can increase awareness of the firm’s value and develop internal auditing system to support the management of these assets. Moreover, it could be a useful instrument for the communication of IC value to the external stakeholders, as customers, suppliers and especially shareholders, and to investors and financial analysts.

  3. Noncontact evaluation for interface states by photocarrier counting

    Science.gov (United States)

    Furuta, Masaaki; Shimizu, Kojiro; Maeta, Takahiro; Miyashita, Moriya; Izunome, Koji; Kubota, Hiroshi

    2018-03-01

    We have developed a noncontact measurement method that enables in-line measurement and does not have any test element group (TEG) formation. In this method, the number of photocarriers excited from the interface states are counted which is called “photocarrier counting”, and then the energy distribution of the interface states density (D it) is evaluated by spectral light excitation. In our previous experiment, the method used was a preliminary contact measurement method at the oxide on top of the Si wafer. We developed, at this time, a D it measurement method as a noncontact measurement with a gap between the probes and the wafer. The shallow trench isolation (STI) sidewall has more localized interface states than the region under the gate electrode. We demonstrate the noncontact measurement of trapped carriers from interface states using wafers of three different crystal plane orientations. The demonstration will pave the way for evaluating STI sidewall interface states in future studies.

  4. Pertussis-associated persistent cough in previously vaccinated children.

    Science.gov (United States)

    Principi, Nicola; Litt, David; Terranova, Leonardo; Picca, Marina; Malvaso, Concetta; Vitale, Cettina; Fry, Norman K; Esposito, Susanna

    2017-11-01

    To evaluate the role of Bordetella pertussis infection, 96 otherwise healthy 7- to 17-year-old subjects who were suffering from a cough lasting from 2 to 8 weeks were prospectively recruited. At enrolment, a nasopharyngeal swab and an oral fluid sample were obtained to search for pertussis infection by the detection of B. pertussis DNA and/or an elevated titre of anti-pertussis toxin IgG. Evidence of pertussis infection was found in 18 (18.7 %; 95 % confidence interval, 11.5-28.0) cases. In 15 cases, the disease occurred despite booster administration. In two cases, pertussis was diagnosed less than 2 years after the booster injection, whereas in the other cases it was diagnosed between 2 and 9 years after the booster dose. This study used non-invasive testing to show that pertussis is one of the most important causes of long-lasting cough in school-age subjects. Moreover, the protection offered by acellular pertussis vaccines currently wanes more rapidly than previously thought.

  5. Development of measures to evaluate youth advocacy for obesity prevention

    OpenAIRE

    Millstein, Rachel A.; Woodruff, Susan I.; Linton, Leslie S.; Edwards, Christine C.; Sallis, James F.

    2016-01-01

    Background Youth advocacy has been successfully used in substance use prevention but is a novel strategy in obesity prevention. As a precondition for building an evidence base for youth advocacy for obesity prevention, the present study aimed to develop and evaluate measures of youth advocacy mediator, process, and outcome variables. Methods The Youth Engagement and Action for Health (YEAH!) program (San Diego County, CA) engaged youth and adult group leaders in advocacy for school and neighb...

  6. Exercise induced ST elevation and residual myocardial ischemia in previous myocardial infarction

    International Nuclear Information System (INIS)

    Shimonagata, Tsuyoshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Saito, Muneyasu; Sumiyoshi, Tetsuya

    1987-01-01

    The purpose of this study was to evaluate the clinical significance of stress induced ST elevation on infarcted area in 65 patients with previous myocardial infarction (single vessel disease) who had stress thallium scan. Stress induced ST changes on infarcted area were compared with quantitative assessment of myocardial ischemia (thallium ischemic score; TIS) and extent of myocardial infarction (defect score; DS) derived from circumferential profile analysis. In patients with previous myocardial infarction in less than 3 month from the onset (n = 36), left ventricular ejection fraction (LVEF) and extent of abnormal LV wall motion were not significantly different between patients with stress induced ST elevation ( ≥ 2 mm, n = 26) and those with stress induced ST elevation ( < 2 mm, n = 10), while, in patients with previous myocardial infarction in more than 3 month (n = 29), patients with stress induced ST elevation ( ≥ 2 mm, n = 15) showed left ventricular dyskinesis more frequently than those with ST elevation ( < 2 mm, n = 14). In addition, the former showed significantly higher DS and significantly lower TIS than the latter. In patients with previous myocardial infarction in less than 3 month, patients with ST elevation ( ≥ 2 mm, n = 15) with prominent upright T wave (n = 15) had transient thallium defect in infarcted area in 73 % and they had significantly higher LVEF and TIS than those with ST elevation ( < 2 mm, n = 11). These results indicated that ST elevation in infarcted area reflect different significance according to the recovery of injured myocardium and stress induced ST elevation with prominent upright T wave in infarcted area reflect residual myocardial ischemia in less than 3 month from the onset of myocardial infarction. (author)

  7. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Impact of previously disadvantaged land-users on sustainable ...

    African Journals Online (AJOL)

    Impact of previously disadvantaged land-users on sustainable agricultural ... about previously disadvantaged land users involved in communal farming systems ... of input, capital, marketing, information and land use planning, with effect on ...

  9. Measurement of the half-life of 68Ga

    International Nuclear Information System (INIS)

    García-Toraño, Eduardo; Peyrés Medina, Virginia; Romero, Eduardo; Roteta, Miguel

    2014-01-01

    The half-life of the positron-emitter 68 Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods of time up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T 1/2 =67.845(18) min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value. - Highlights: • The half-life of the positron-emitter radionuclide 68 Ga was measured. • Two measurement setups (ionization chamber and Ge detector) were used. • Results agree with evaluated data but exhibit lower uncertainty

  10. Determination of the Boltzmann constant with cylindrical acoustic gas thermometry: new and previous results combined

    Science.gov (United States)

    Feng, X. J.; Zhang, J. T.; Lin, H.; Gillis, K. A.; Mehl, J. B.; Moldover, M. R.; Zhang, K.; Duan, Y. N.

    2017-10-01

    We report a new determination of the Boltzmann constant k B using a cylindrical acoustic gas thermometer. We determined the length of the copper cavity from measurements of its microwave resonance frequencies. This contrasts with our previous work (Zhang et al 2011 Int. J. Thermophys. 32 1297, Lin et al 2013 Metrologia 50 417, Feng et al 2015 Metrologia 52 S343) that determined the length of a different cavity using two-color optical interferometry. In this new study, the half-widths of the acoustic resonances are closer to their theoretical values than in our previous work. Despite significant changes in resonator design and the way in which the cylinder length is determined, the value of k B is substantially unchanged. We combined this result with our four previous results to calculate a global weighted mean of our k B determinations. The calculation follows CODATA’s method (Mohr and Taylor 2000 Rev. Mod. Phys. 72 351) for obtaining the weighted mean value of k B that accounts for the correlations among the measured quantities in this work and in our four previous determinations of k B. The weighted mean {{\\boldsymbol{\\hat{k}}}{B}} is 1.380 6484(28)  ×  10-23 J K-1 with the relative standard uncertainty of 2.0  ×  10-6. The corresponding value of the universal gas constant is 8.314 459(17) J K-1 mol-1 with the relative standard uncertainty of 2.0  ×  10-6.

  11. Beta measurement evaluation and upgrade

    International Nuclear Information System (INIS)

    Swinth, K.L.; Rathbun, L.A.; Roberson, P.L.; Endres, G.W.R.

    1986-01-01

    This program focuses on the resolution of problems associated with the field measurement of the beta dose component at Department of Energy (DOE) facilities. The change in DOE programs, including increased efforts in improved waste management and decontamination and decommissioning (D and D) of facilities, coupled with beta measurement problems identified at Three Mile Island has increased the need to improve beta measurements. In FY 1982, work was initiated to provide a continuing effort to identify problems associated with beta dose assessment at DOE facilities. The problems identified resulted in the development of this program. The investigation includes (1) an assessment of measurement systems now in use, (2) development of improved calibration systems and procedures, (3) application of innovative beta dosimetry concepts, (4) investigation of new instruments or concepts for monitoring and spectroscopy, and (5) development of recommendations to assure an adequate beta measurement program within DOE facilities

  12. Evaluation of cladding residual stresses in clad blocks by measurements and numerical simulations

    International Nuclear Information System (INIS)

    Dupas, P.; Moinereau, D.

    1996-01-01

    Reactor pressure vessels are internally clad with austenitic stainless steel. This welding operation generates residual stresses which can have an important role in integrity assessments. In order to evaluate these stresses, an experimental and numerical programme has been conducted. The experiments includes cladding operations, macrographic analyses, temperature and residual stresses measurements with different methods. According to these measurements, transversal stresses (perpendicular to the welding direction) and longitudinal stresses (parallel to the welding direction) are highly tensile in stainless steel and they are compressive in the HAZ. Finite element calculations were used to simulate both welding operations and post weld heat treatment. These calculations coupled the thermal, metallurgical and mechanical aspects in a 2D representation. Different models were studied including effect of generalised plane strain, transformation plasticity, creep and tempering. The transversal stresses calculated are similar to the measured ones, but the longitudinal stresses showed to be very sensitive to the model used. As expected because of the two-dimension model, the longitudinal stresses can't be well estimated. More work is needed to improve measurements of stresses in depth (important differences appeared between the different methods). A predictive model would be also very useful to determine the thermal loading which is at present dependant on measurements. A 3D calculation appears to be necessary to evaluate longitudinal stresses. (orig.)

  13. Psychometric evaluation and design of patient-centered communication measures for cancer care settings.

    Science.gov (United States)

    Reeve, Bryce B; Thissen, David M; Bann, Carla M; Mack, Nicole; Treiman, Katherine; Sanoff, Hanna K; Roach, Nancy; Magnus, Brooke E; He, Jason; Wagner, Laura K; Moultrie, Rebecca; Jackson, Kathryn D; Mann, Courtney; McCormack, Lauren A

    2017-07-01

    To evaluate the psychometric properties of questions that assess patient perceptions of patient-provider communication and design measures of patient-centered communication (PCC). Participants (adults with colon or rectal cancer living in North Carolina) completed a survey at 2 to 3 months post-diagnosis. The survey included 87 questions in six PCC Functions: Exchanging Information, Fostering Health Relationships, Making Decisions, Responding to Emotions, Enabling Patient Self-Management, and Managing Uncertainty. For each Function we conducted factor analyses, item response theory modeling, and tests for differential item functioning, and assessed reliability and construct validity. Participants included 501 respondents; 46% had a high school education or less. Reliability within each Function ranged from 0.90 to 0.96. The PCC-Ca-36 (36-question survey; reliability=0.94) and PCC-Ca-6 (6-question survey; reliability=0.92) measures differentiated between individuals with poor and good health (i.e., known-groups validity) and were highly correlated with the HINTS communication scale (i.e., convergent validity). This study provides theory-grounded PCC measures found to be reliable and valid in colorectal cancer patients in North Carolina. Future work should evaluate measure validity over time and in other cancer populations. The PCC-Ca-36 and PCC-Ca-6 measures may be used for surveillance, intervention research, and quality improvement initiatives. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Measurement properties of exsisting clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, B; Lund, H

    (COSMIN checklist), the methodological quality in the reliability and validity domains was ‘fair’ (57%) to ‘poor’ (43%), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement......MEASUREMENT PROPERTIES OF EXISTING CLINICAL ASSESSMENT METHODS EVALUATING SCAPULAR POSITIONING AND FUNCTION. A SYSTEMATIC REVIEW1,2Camilla Marie Larsen, 1,3Birgit Juul-Kristensen, 1,3Hans Lund, 1Karen Søgaard1Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark2......,2]. Rehabilitation exercises are aiming at altering abnormal/asymmetric scapular positioning and/or function. Numerous assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3...

  15. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans

    %), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement properties demonstrated acceptable results for both reliability and validity.ConclusionWe found a substantially larger number......ABSTRACT OARSI Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review Larsen CM1, Juul-Kristensen B1,2 Lund H1,2, Søgaard K11University of Southern Denmark, Institute of Sports Science and Clinical Biomechanics2Institute...... assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3-dimensional electromagnetic device or 2-dimensional clinically applicable methods. Since advanced equipment (i.e. 3D...

  16. Measuring Teaching Quality in Higher Education: Assessing Selection Bias in Course Evaluations

    Science.gov (United States)

    Goos, Maarten; Salomons, Anna

    2017-01-01

    Student evaluations of teaching (SETs) are widely used to measure teaching quality in higher education and compare it across different courses, teachers, departments and institutions. Indeed, SETs are of increasing importance for teacher promotion decisions, student course selection, as well as for auditing practices demonstrating institutional…

  17. An independent psychometric evaluation of the PROMS measure of music perception skills

    NARCIS (Netherlands)

    Kunert, R.; Willems, R.M.; Hagoort, P.

    2016-01-01

    The Profile of Music Perception Skills (PROMS) is a recently developed measure of perceptual music skills which has been shown to have promising psychometric properties. In this paper we extend the evaluation of its brief version to three kinds of validity using an individual difference approach.

  18. Evaluation of stresses generated in steel finger joint of bridge by X-ray stress measurement

    International Nuclear Information System (INIS)

    Kohri, Ami; Kawano, Yutaka; Nishido, Takayuki

    2017-01-01

    In a steel bridge, the evaluation of the stress generated in the finger joint without a gap to absorb temperature change can be an index when evaluating the remaining life. This study chose as the object the finger joint of a diagonal bridge, where the generated stress state is considered to be more complicated, prepared a finger joint test specimen that simulated an actual part, and performed a load test. For judgment, FEM analysis, non-destructive X-ray stress measurement, and measurement of the generated stress using strain gauge were applied. Compared with the FEM analysis results, the difference in the stress value was generated due to the difference in the contact state, but the trends of the stress distribution were equivalent. In addition, the same measurement value as the strain gauge was obtained, and the validity of the X-ray stress measurement method was confirmed. As a result, it was found that the stress measurement method by X-ray is effective for measuring the generated stress including the residual stress of the finger joint without gap at a bridge. (A.O.)

  19. Development and psychometric evaluation of the Undergraduate Clinical Education Environment Measure (UCEEM).

    Science.gov (United States)

    Strand, Pia; Sjöborg, Karolina; Stalmeijer, Renée; Wichmann-Hansen, Gitte; Jakobsson, Ulf; Edgren, Gudrun

    2013-12-01

    There is a paucity of instruments designed to evaluate the multiple dimensions of the workplace as an educational environment for undergraduate medical students. The aim was to develop and psychometrically evaluate an instrument to measure how undergraduate medical students perceive the clinical workplace environment, based on workplace learning theories and empirical findings. Development of the instrument relied on established standards including theoretical and empirical grounding, systematic item development and expert review at various stages to ensure content validity. Qualitative and quantitative methods were employed using a series of steps from conceptualization through psychometric analysis of scores in a Swedish medical student population. The final result was a 25-item instrument with two overarching dimensions, experiential learning and social participation, and four subscales that coincided well with theory and empirical findings: Opportunities to learn in and through work & quality of supervision; Preparedness for student entry; Workplace interaction patterns & student inclusion; and Equal treatment. Evidence from various sources supported content validity, construct validity and reliability of the instrument. The Undergraduate Clinical Education Environment Measure represents a valid, reliable and feasible multidimensional instrument for evaluation of the clinical workplace as a learning environment for undergraduate medical students. Further validation in different populations using various psychometric methods is needed.

  20. Measuring Down: Evaluating Digital Storytelling as a Process for Narrative Health Promotion.

    Science.gov (United States)

    Gubrium, Aline C; Fiddian-Green, Alice; Lowe, Sarah; DiFulvio, Gloria; Del Toro-Mejías, Lizbeth

    2016-05-15

    Digital storytelling (DST) engages participants in a group-based process to create and share narrative accounts of life events. We present key evaluation findings of a 2-year, mixed-methods study that focused on effects of participating in the DST process on young Puerto Rican Latina's self-esteem, social support, empowerment, and sexual attitudes and behaviors. Quantitative results did not show significant changes in the expected outcomes. However, in our qualitative findings we identified several ways in which the DST made positive, health-bearing effects. We argue for the importance of "measuring down" to reflect the locally grounded, felt experiences of participants who engage in the process, as current quantitative scales do not "measure up" to accurately capture these effects. We end by suggesting the need to develop mixed-methods, culturally relevant, and sensitive evaluation tools that prioritize process effects as they inform intervention and health promotion. © The Author(s) 2016.

  1. Nuclear-data evaluation based on direct and indirect measurements with general correlations

    International Nuclear Information System (INIS)

    Muir, D.W.

    1988-01-01

    Optimum procedures for the statistical improvement, or updating, of an existing nuclear-data evaluation are reviewed and redeveloped from first principles, consistently employing a minimum-variance viewpoint. A set of equations is derived which provides improved values of the data and their covariances, taking into account information from supplementary measurements and allowing for general correlations among all measurements. The minimum-variance solutions thus obtained, which we call the method of 'partitioned least squares,' are found to be equivalent to a method suggested by Yu. V. Linnik and applied by a number of authors to the analysis of fission-reactor integral experiments; however, up to now, the partitioned-least-squares formulae have not found widespread use in the field of basic data evaluation. This approach is shown to give the same results as the more commonly applied Normal equations, but with reduced matrix inversion requirements. Examples are provided to indicate potential areas of application. (author)

  2. Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study

    DEFF Research Database (Denmark)

    Kjaer, L; Thomsen, C; Henriksen, O

    1987-01-01

    Several circumstances may explain the great variation in reported proton T1 and T2 relaxation times usually seen. This study was designed to evaluate the accuracy of relaxation time measurements by magnetic resonance imaging (MRI) operating at 1.5 tesla. Using a phantom of nine boxes with different...... concentrations of CuSO4 and correlating the calculated T1 and T2 values with reference values obtained by two spectrometers (corrected to MRI-proton frequency = 64 MHz) we found a maximum deviation of about 10 per cent. Measurements performed on a large water phantom in order to evaluate the homogeneity...... in the imaging plane showed a variation of less than 10 per cent within 10 cm from the centre of the magnet in all three imaging planes. Changing the gradient field strength apparently had no influence on the T2 values recorded. Consequently diffusion processes seem without significance. It is concluded...

  3. In vitro evaluation of oestrogenic/androgenic activity of the serum organochlorine pesticide mixtures previously described in a breast cancer case–control study

    International Nuclear Information System (INIS)

    Rivero, Javier; Luzardo, Octavio P.; Henríquez-Hernández, Luis A.; Machín, Rubén P.; Pestano, José; Zumbado, Manuel; Boada, Luis D.; Camacho, María; Valerón, Pilar F.

    2015-01-01

    Some organochlorine pesticides (OCs) have been individually linked to breast cancer (BC) because they exert oestrogenic effects on mammary cells. However, humans are environmentally exposed to more or less complex mixtures of these organochlorines, and the biological effects of these mixtures must be elucidated. In this work we evaluated the in vitro effects exerted on human BC cells by the OC mixtures that were most frequently detected in two groups of women who participated in a BC case–control study developed in Spain: healthy women and women diagnosed with BC. The cytotoxicity, oestrogenicity, and androgenicity of the most prevalent OC mixtures found in healthy women (H-mixture) and in BC patients (BC-mixture) were tested at concentrations that resembled those found in the serum of the evaluated women. Our results showed that both OC mixtures presented a similar oestrogenic activity and effect on cell viability, but BC-mixture showed an additional anti-androgenic effect. These results indicate that although the proliferative effect exerted by these mixtures on human breast cells seems to depend mainly on their oestrogenic action, the BC-mixture might additionally induce cell proliferation due to its anti-androgenic activity, therefore increasing the carcinogenic potential of this mixture. The findings of this study demonstrate that subtle variations in the composition of a mixture may induce relevant changes in its biological action. - Highlights: • E-screen and A-screen of two mixtures of organochlorine pesticides (OCP) • Assay concentrations based on a previous breast cancer case–control study • Only non-cytotoxic concentrations assayed • Both OCP mixtures induce proliferation mediated by oestrogen receptor. • OCP mixture of breast cancer patients exhibits additional androgenic activity.

  4. In vitro evaluation of oestrogenic/androgenic activity of the serum organochlorine pesticide mixtures previously described in a breast cancer case–control study

    Energy Technology Data Exchange (ETDEWEB)

    Rivero, Javier; Luzardo, Octavio P., E-mail: octavio.perez@ulpgc.es; Henríquez-Hernández, Luis A.; Machín, Rubén P.; Pestano, José; Zumbado, Manuel; Boada, Luis D.; Camacho, María; Valerón, Pilar F.

    2015-12-15

    Some organochlorine pesticides (OCs) have been individually linked to breast cancer (BC) because they exert oestrogenic effects on mammary cells. However, humans are environmentally exposed to more or less complex mixtures of these organochlorines, and the biological effects of these mixtures must be elucidated. In this work we evaluated the in vitro effects exerted on human BC cells by the OC mixtures that were most frequently detected in two groups of women who participated in a BC case–control study developed in Spain: healthy women and women diagnosed with BC. The cytotoxicity, oestrogenicity, and androgenicity of the most prevalent OC mixtures found in healthy women (H-mixture) and in BC patients (BC-mixture) were tested at concentrations that resembled those found in the serum of the evaluated women. Our results showed that both OC mixtures presented a similar oestrogenic activity and effect on cell viability, but BC-mixture showed an additional anti-androgenic effect. These results indicate that although the proliferative effect exerted by these mixtures on human breast cells seems to depend mainly on their oestrogenic action, the BC-mixture might additionally induce cell proliferation due to its anti-androgenic activity, therefore increasing the carcinogenic potential of this mixture. The findings of this study demonstrate that subtle variations in the composition of a mixture may induce relevant changes in its biological action. - Highlights: • E-screen and A-screen of two mixtures of organochlorine pesticides (OCP) • Assay concentrations based on a previous breast cancer case–control study • Only non-cytotoxic concentrations assayed • Both OCP mixtures induce proliferation mediated by oestrogen receptor. • OCP mixture of breast cancer patients exhibits additional androgenic activity.

  5. Determining root correspondence between previously and newly detected objects

    Science.gov (United States)

    Paglieroni, David W.; Beer, N Reginald

    2014-06-17

    A system that applies attribute and topology based change detection to networks of objects that were detected on previous scans of a structure, roadway, or area of interest. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, size, elongation, orientation, etc. The topology of the network of previously detected objects is maintained in a constellation database that stores attributes of previously detected objects and implicitly captures the geometrical structure of the network. A change detection system detects change by comparing the attributes and topology of new objects detected on the latest scan to the constellation database of previously detected objects.

  6. Effectiveness evaluation of the tube voltage measurement by using additional filter

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jun Ho; Lee, Kyung Ho; Choi, Yoon Bong [Dept. of Radiology, Kyung Hee University Medical Center, Seoul (Korea, Republic of); Kang, Byung Sam [Dept. of Radiological Technology, Shingu College, Sungnam (Korea, Republic of)

    2015-12-15

    Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ±10%, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ⁓ 85 % , a gradual increase in concentration to 85 ⁓ 110 % was noted.

  7. Effectiveness evaluation of the tube voltage measurement by using additional filter

    International Nuclear Information System (INIS)

    Hwang, Jun Ho; Lee, Kyung Ho; Choi, Yoon Bong; Kang, Byung Sam

    2015-01-01

    Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ±10%, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ⁓ 85 % , a gradual increase in concentration to 85 ⁓ 110 % was noted

  8. Evaluating the auralization of a small room in a virtual sound environment using objective room acoustic measures

    DEFF Research Database (Denmark)

    Ahrens, Axel; Marschall, Marton; Dau, Torsten

    2016-01-01

    To study human auditory perception in realistic environments, loudspeaker-based reproduction techniques have recently become state-of-the-art. To evaluate the accuracy of a simulation-based room auralization of a small room, objective measures, such as early-decay-time (EDT), reverberation time...... of the room. The auralizations were generated using the loudspeaker-based room auralization toolbox (LoRA; Favrot and Buchholz, 2010) and reproduced in a 64-channel loudspeaker array, set up in an anechoic chamber. Differences between the objective measures evaluated in the real and the virtual room were......, clarity, interaural cross-correlation (IACC), and the speech transmission index were measured in an IEC listening room for 28 source-receiver combinations. The room was then modeled in the room acoustics software ODEON, and the same objective measures were also evaluated for the auralized version...

  9. Initial constructs for patient-centered outcome measures to evaluate brain-computer interfaces.

    Science.gov (United States)

    Andresen, Elena M; Fried-Oken, Melanie; Peters, Betts; Patrick, Donald L

    2016-10-01

    The authors describe preliminary work toward the creation of patient-centered outcome (PCO) measures to evaluate brain-computer interface (BCI) as an assistive technology (AT) for individuals with severe speech and physical impairments (SSPI). In Phase 1, 591 items from 15 existing measures were mapped to the International Classification of Functioning, Disability and Health (ICF). In Phase 2, qualitative interviews were conducted with eight people with SSPI and seven caregivers. Resulting text data were coded in an iterative analysis. Most items (79%) were mapped to the ICF environmental domain; over half (53%) were mapped to more than one domain. The ICF framework was well suited for mapping items related to body functions and structures, but less so for items in other areas, including personal factors. Two constructs emerged from qualitative data: quality of life (QOL) and AT. Component domains and themes were identified for each. Preliminary constructs, domains and themes were generated for future PCO measures relevant to BCI. Existing instruments are sufficient for initial items but do not adequately match the values of people with SSPI and their caregivers. Field methods for interviewing people with SSPI were successful, and support the inclusion of these individuals in PCO research. Implications for Rehabilitation Adapted interview methods allow people with severe speech and physical impairments to participate in patient-centered outcomes research. Patient-centered outcome measures are needed to evaluate the clinical implementation of brain-computer interface as an assistive technology.

  10. Measuring team-based interprofessional education outcomes in clinical dentistry: psychometric evaluation of a new scale at an Australian dental school.

    Science.gov (United States)

    Storrs, Mark J; Alexander, Heather; Sun, Jing; Kroon, Jeroen; Evans, Jane L

    2015-03-01

    Previous research on interprofessional education (IPE) assessment has shown the need to evaluate the influence of team-based processes on the quality of clinical education. This study aimed to develop a valid and reliable instrument to evaluate the effectiveness of interprofessional team-based treatment planning (TBTP) on the quality of clinical education at the Griffith University School of Dentistry and Oral Health, Queensland, Australia. A scale was developed and evaluated to measure interprofessional student team processes and their effect on the quality of clinical education for dental, oral health therapy, and dental technology students (known more frequently as intraprofessional education). A face validity analysis by IPE experts confirmed that items on the scale reflected the meaning of relevant concepts. After piloting, 158 students (61% response rate) involved with TBTP participated in a survey. An exploratory factor analysis using the principal component method retained 23 items with a total variance of 64.6%, suggesting high content validity. Three subscales accounted for 45.7%, 11.4%, and 7.5% of the variance. Internal consistency of the scale (α=0.943) and subscales 1 (α=0.953), 2 (α=0.897), and 3 (α=0.813) was high. A reliability analysis yielded moderate (rs=0.43) to high correlations (0.81) with the remaining scale items. Confirmatory factor analyses verified convergent validity and confirmed that this structure had a good model fit. This study suggests that the instrument might be useful in evaluating interprofessional or intraprofessional team-based processes and their influence on the quality of clinical education in academic dental institutions.

  11. AbobotulinumtoxinA Efficacy and Safety in Children With Equinus Foot Previously Treated With Botulinum Toxin.

    Science.gov (United States)

    Dabrowski, Edward; Bonikowski, Marcin; Gormley, Mark; Volteau, Magali; Picaut, Philippe; Delgado, Mauricio R

    2018-05-01

    The effects of botulinum toxin are transient, and repeat injections are required in children with lower-limb spasticity. However, the efficacy of botulinum toxin in patients who have received previous injections has remained largely unexplored. We present subgroup analyses of a phase III study conducted in ambulatory children (aged two to 17) with spastic equinus foot. Patients were randomized to single doses of abobotulinumtoxinA 10 U/kg/leg, 15 U/kg/leg, or placebo injected into the gastrocnemius-soleus complex (one or both legs). The first analysis was prespecified to review the effect of abobotulinumtoxinA in children previously treated with botulinum toxin versus those children new to the treatment; a second post hoc analysis evaluated the effect of abobotulinumtoxinA in children who changed botulinum toxin formulation. Of the 241 randomized patients, 113 had previously received botulinum toxin, including 86 who had been treated with another formulation. In both analyses, muscle tone (Modified Ashworth Scale) and the Physicians Global Assessment, at week 4, improved with abobotulinumtoxinA treatment versus placebo, regardless of baseline botulinum toxin status. Placebo responses in patients new to treatment were consistently higher than in the previously treated group. These results demonstrate similar abobotulinumtoxinA efficacy and safety profiles in children with spasticity who are new to botulinum toxin treatment and those children who were previously treated. The efficacy and safety of abobotulinumtoxinA treatment in these previously treated patients were comparable with the overall trial population, indicating that doses of 10 and 15 U/kg/leg are suitable starting doses for children with spasticity regardless of the previous botulinum toxin preparation used. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Outcomes of LASIK and PRK in previous penetrating corneal transplant recipients.

    Science.gov (United States)

    Kovoor, Timmy A; Mohamed, Engy; Cavanagh, H Dwight; Bowman, R Wayne

    2009-09-01

    To evaluate the safety and efficacy of excimer laser refractive surgery in correcting refractive error in eyes that have undergone previous penetrating keratoplasty (PK). Twenty-three keratorefractive procedures on 16 eyes from 16 consecutive subjects were evaluated between 2002 and 2008. Each patient presented a previous history of a PK with subsequent postoperative myopia and astigmatism. Keratometric value, manifest refraction, best-corrected visual acuity, uncorrected visual acuity, and complications were determined. There were a total of 14 photorefractive keratectomy (PRK) procedures performed on 11 eyes and 9 laser in situ keratomileusis (LASIK) procedures performed on 5 eyes. In the PRK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -6.22 +/- 6.23 diopter and 5.23 +/- 2.26 D, respectively. The PRK postoperative manifest refractive spherical equivalent and cylindrical error were -3.61 +/- 4.23 D (P=0.25) and 3.21 +/- 1.78 D (P=0.02), respectively. In the LASIK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -3.05 +/- 3.29 D and 4.11 +/- 2.38 D, respectively. The LASIK postoperative manifest refractive spherical equivalent and cylindrical error were -1.51 +/- 2.02 D (P=0.24) and 2.08 +/- 1.26 D (P=0.03), respectively. There was a 2-line or greater improvement of uncorrected visual acuity in 8 of the 14 PRK treatments and 5 of the 9 LASIK treatments. There were two episodes of acute graft rejection. One of the episodes resolved with topical and oral corticosteroids, and the other episode required a repeat corneal transplantation. PRK and LASIK are effective tools in reducing surgically induced astigmatism after penetrating corneal transplantation in most patients in this case series. The reduction of astigmatism may allow improved contact lens or spectacle fitting to achieve best-corrected binocular visual acuity.

  13. First evaluation of low frequency noise measurements of in core detector signals in the measuring assembly Rheinsberg

    International Nuclear Information System (INIS)

    Collatz, S.

    1982-01-01

    Reactor noise spectra of in core neutron detectors are measured in the low frequency range (0.03 Hz to 1 Hz) and evaluated. The increase of the effective noise signal value is due to pressure oscillations or oscillations of special steam volume portions. Thus boiling monitoring of reactor cores in PWR type reactors may be possible, if the low frequency noise of the whole set of in core detectors is taken into account

  14. Performance evaluation of CT measurements made on step gauges using statistical methodologies

    DEFF Research Database (Denmark)

    Angel, J.; De Chiffre, L.; Kruth, J.P.

    2015-01-01

    In this paper, a study is presented in which statistical methodologies were applied to evaluate the measurement of step gauges on an X-ray computed tomography (CT) system. In particular, the effects of step gauge material density and orientation were investigated. The step gauges consist of uni......- and bidirectional lengths. By confirming the repeatability of measurements made on the test system, the number of required scans in the design of experiment (DOE) was reduced. The statistical model was checked using model adequacy principles; model adequacy checking is an important step in validating...

  15. Measuring value for money: a scoping review on economic evaluation of health information systems.

    Science.gov (United States)

    Bassi, Jesdeep; Lau, Francis

    2013-01-01

    To explore how key components of economic evaluations have been included in evaluations of health information systems (HIS), to determine the state of knowledge on value for money for HIS, and provide guidance for future evaluations. We searched databases, previously collected papers, and references for relevant papers published from January 2000 to June 2012. For selection, papers had to: be a primary study; involve a computerized system for health information processing, decision support, or management reporting; and include an economic evaluation. Data on study design and economic evaluation methods were extracted and analyzed. Forty-two papers were selected and 33 were deemed high quality (scores ≥ 8/10) for further analysis. These included 12 economic analyses, five input cost analyses, and 16 cost-related outcome analyses. For HIS types, there were seven primary care electronic medical records, six computerized provider order entry systems, five medication management systems, five immunization information systems, four institutional information systems, three disease management systems, two clinical documentation systems, and one health information exchange network. In terms of value for money, 23 papers reported positive findings, eight were inconclusive, and two were negative. We found a wide range of economic evaluation papers that were based on different assumptions, methods, and metrics. There is some evidence of value for money in selected healthcare organizations and HIS types. However, caution is needed when generalizing these findings. Better reporting of economic evaluation studies is needed to compare findings and build on the existing evidence base we identified.

  16. Urinary incontinence and vaginal squeeze pressure two years post-cesarean delivery in primiparous women with previous gestational diabetes mellitus

    OpenAIRE

    Barbosa, Angélica Mércia Pascon; Dias, Adriano; Marini, Gabriela; Calderon, Iracema Mattos Paranhos; Witkin, Steven; Rudge, Marilza Vieira Cunha

    2011-01-01

    OBJECTIVE: To assess the prevalence of urinary incontinence and associated vaginal squeeze pressure in primiparous women with and without previous gestational diabetes mellitus two years post-cesarean delivery. METHODS: Primiparous women who delivered by cesarean two years previously were interviewed about the delivery and the occurrence of incontinence. Incontinence was reported by the women and vaginal pressure evaluated by a Perina perineometer. Sixty-three women with gestational diabetes ...

  17. Surveying for "artifacts": the susceptibility of the OCB-performance evaluation relationship to common rater, item, and measurement context effects.

    Science.gov (United States)

    Podsakoff, Nathan P; Whiting, Steven W; Welsh, David T; Mai, Ke Michael

    2013-09-01

    Despite the increased attention paid to biases attributable to common method variance (CMV) over the past 50 years, researchers have only recently begun to systematically examine the effect of specific sources of CMV in previously published empirical studies. Our study contributes to this research by examining the extent to which common rater, item, and measurement context characteristics bias the relationships between organizational citizenship behaviors and performance evaluations using a mixed-effects analytic technique. Results from 173 correlations reported in 81 empirical studies (N = 31,146) indicate that even after controlling for study-level factors, common rater and anchor point number similarity substantially biased the focal correlations. Indeed, these sources of CMV (a) led to estimates that were between 60% and 96% larger when comparing measures obtained from a common rater, versus different raters; (b) led to 39% larger estimates when a common source rated the scales using the same number, versus a different number, of anchor points; and (c) when taken together with other study-level predictors, accounted for over half of the between-study variance in the focal correlations. We discuss the implications for researchers and practitioners and provide recommendations for future research. PsycINFO Database Record (c) 2013 APA, all rights reserved

  18. Flow Experience as a Quality Measure in Evaluating Physically Activating Collaborative Serious Games

    Directory of Open Access Journals (Sweden)

    Kristian J. M. Kiili

    2014-09-01

    Full Text Available The measurement of the subjective playing experience is important part of the game development process. The enjoyment level that a serious game offers is a key factor in determining whether a player will be engaged in the gameplay and achieve the objectives of the game. In this paper we report the results of a game design process in which two prototypes of a collaborative exergame were studied. The main aim of the paper is to explore to what extend the measurement of flow experience can facilitate the game evaluation and design process. Alltogether 102 junior high school students participated in two user experience studies and played collaborative exergames designed to teach soft skills. Playing experience was measured with a flow questionnaire, playing behavior was observed and some of the players were interviewed. The results showed that flow experience can be used to evaluate the overall quality of the gameplay and it provides a structured approach to consider the quality of the game. However, flow does not provide detailed information about the shortages of the game and thus complementary methods is needed to identify the causes. The results also indicated that flow experience was independent of gender that supports its use in quality measurement.

  19. Initial results of CyberKnife treatment for recurrent previously irradiated head and neck cancer

    International Nuclear Information System (INIS)

    Himei, Kengo; Katsui, Kuniaki; Yoshida, Atsushi

    2003-01-01

    The purpose of this study was to evaluate the efficacy of CyberKnife for recurrent previously irradiated head and neck cancer. Thirty-one patients with recurrent previously irradiated head and neck cancer were treated with a CyberKnife from July 1999 to March 2002 at Okayama Kyokuto Hospital were retrospectively studied. The accumulated dose was 28-80 Gy (median 60 Gy). The interval between CyberKnife treatment and previous radiotherapy was 0.4-429.5 months (median 16.3 months). Primary lesions were nasopharynx: 7, maxillary sinus: 6, tongue: 5, ethmoid sinus: 3, and others: 1. The pathology was squamous cell carcinoma: 25, adenoid cystic carcinoma: 4, and others: 2. Symptoms were pain: 8, and nasal bleeding: 2. The prescribed dose was 15.0-40.3 Gy (median 32.3 Gy) as for the marginal dose. The response rate (complete response (CR)+partial response (PR)) and local control rate (CR+PR+no change (NC)) was 74% and 94% respectively. Pain disappeared for 4 cases, relief was obtained for 4 cases and no change for 2 cases and nasal bleeding disappeared for 2 cases for an improvement of symptoms. An adverse effects were observed as mucositis in 5 cases and neck swelling in one case. Prognosis of recurrent previously irradiated head and neck cancer was estimated as poor. Our early experience shows that CyberKnife is expected to be feasible treatment for recurrent previously irradiated head and neck cancer, and for the reduction adverse effects and maintenance of useful quality of life (QOL) for patients. (author)

  20. Measurement and evaluation of the external radiation level at reactor Kartini

    International Nuclear Information System (INIS)

    Atok Suhartanto; Suparno

    2013-01-01

    Measurement and evaluation of external radiation level at reactor Kartini in 2012 has been done. The purpose of this activity is to know the external radiation level as a result of the radioactive or radiation source usage, toward the operational of limit condition. The measurement is using survey meter Inspector 11086, factor of calibration 0.991 mR/h, at 9 locations is: Control room area, Thermal column facilities, Demineralizer, Beamport radiography facilities, bulk shielding Deck, Subcritical facilities, Reactor hall, Deck reactor and on the surface of reactor water tank . The highest room average measurement result in 9 working areas for 12 months continuously are at the reactor tank location is between 13.05±1.09 (xlO -2 mSv/hour) to 16.80±1.40 (x10 -2 mSv/hour), and the lowest measurement result in 1 location (control room) is 0.02±0.005 (x10 -2 mSv/hour) to 0.035±0.009 (x10 -2 mSv/hour). The Kartini reactor is involved in the control area which has potentially contaminated and has radiation exposure at the level of 6 mSv/year. Radiation Protection Officer that work in interval will received radiation exposure dosage of 8.4 mSv/year. This dosage is still below the Below Dosage Value which is recommended by, BAPETEN decree No, 4, 2013 about Protection and Radiation Safety in Nuclear Energy Application at 20 mSv/year. The result of the evaluation above shows that the external radiation which occurred in each area is still below the operational of limit condition that is written on the Kartini reactor safety analysis report, on document number: C7/05/B2/LAK/2010, revision 7. So that the workplace is safe for work monitored. (author)

  1. Indiana pouch continent urinary reservoir in patients with previous pelvic irradiation

    International Nuclear Information System (INIS)

    Mannel, R.S.; Braly, P.S.; Buller, R.E.

    1990-01-01

    Little information exists on the use of continent urinary reservoirs in patients with previous pelvic irradiation. We report the use of the Indiana pouch urinary reservoir in ten women with a history of pelvic irradiation for cervical cancer, of whom eight underwent a total pelvic exenteration for recurrent pelvic tumor and two had diversion for radiation-induced vesicovaginal fistula. All ten women achieved daytime continence, with a median time between catheterizations of 4.5 hours and a median pouch capacity of 500 mL. There was no evidence of leakage from the reservoir or significant ureteral reflux or obstruction on postoperative radiographic evaluation. No patient has required reoperation or had significant postoperative complications with the technique described

  2. Erlotinib-induced rash spares previously irradiated skin

    International Nuclear Information System (INIS)

    Lips, Irene M.; Vonk, Ernest J.A.; Koster, Mariska E.Y.; Houwing, Ronald H.

    2011-01-01

    Erlotinib is an epidermal growth factor receptor inhibitor prescribed to patients with locally advanced or metastasized non-small cell lung carcinoma after failure of at least one earlier chemotherapy treatment. Approximately 75% of the patients treated with erlotinib develop acneiform skin rashes. A patient treated with erlotinib 3 months after finishing concomitant treatment with chemotherapy and radiotherapy for non-small cell lung cancer is presented. Unexpectedly, the part of the skin that had been included in his previously radiotherapy field was completely spared from the erlotinib-induced acneiform skin rash. The exact mechanism of erlotinib-induced rash sparing in previously irradiated skin is unclear. The underlying mechanism of this phenomenon needs to be explored further, because the number of patients being treated with a combination of both therapeutic modalities is increasing. The therapeutic effect of erlotinib in the area of the previously irradiated lesion should be assessed. (orig.)

  3. Evaluation of microcomputer assisted system for nuclear emulsion measurement, 2

    International Nuclear Information System (INIS)

    Sato, Yoshihiro; Tezuka, Ikuo; Izawa, Kazuo.

    1983-01-01

    In the reaction of hardrons of several hundreds GeV/c, charm particles with from 10 -12 to 10 -13 second lifetime and beauty particles of shorter lifetime are generated. For directly observing these particles, the experiment using a system which combines nuclear emulsion and an electronic counter is carried out. The authors have engaged in the development of a nuclear emulsion analyzing system since several years ago, and recently developed a program for that system, and made measurement using the program, as one of the works to participate in the NA-19 hybrid experiment of this type, which is a high energy experiment implemented with the CERN accelerator using 350 GeV/c π - beam. In this report, first the outline of NA-19 experiment, next the corresponding of counter coordinates to nuclear emulsions, and the search for candidate events, in which two or more muons exist, that passed iron and tungsten dampers, are described. Further, the measuring programs XPRED 5 and CRS 34 and the relationship between these programs and measuring procedure and the evaluation for them are described at the end. The present program allows the measurement of generated secondary particles without any trouble up to the distance of 5 mm downstream from the collision point. It was also found that the program was applicable to the measurement of the decay phenomena and kink of the particles expected in the measurement of short-life particles. The system capability of estimating the position of target particles within 10 μm greatly contributes to this. (Wakatsuki, Y.)

  4. Evaluation of the Street Pollution Model OSPM for Measurements at 12 Streets Stations Using a Newly Developed and Freely Available Evaluation Tool

    DEFF Research Database (Denmark)

    Ketzel, Matthias; Jensen, Steen Solvang; Brandt, Jørgen

    2012-01-01

    In the present work, the Operational Street Pollution Model (OSPM) has been evaluated in comparison with continuous half-hourly measurements over a multi-year period for five permanent street monitor stations that constitute part of the Danish Air Quality Monitoring Programme as well as with pass......In the present work, the Operational Street Pollution Model (OSPM) has been evaluated in comparison with continuous half-hourly measurements over a multi-year period for five permanent street monitor stations that constitute part of the Danish Air Quality Monitoring Programme as well...... the observations well, especially for the most recent years, while for NO2 the model over-predicts in two cases. The explanation for this over-prediction is believed to be uncertainties in the traffic or emission input data, but also in model parameters, and the representativeness of the urban background data may....... OSPM calculations for nine streets with passive sampler measurements were conducted as ‘blind test’ i.e. without knowing the measured values. OSPM calculations were in good agreement with the measurements for seven out of nine street sections. Refinements of the input data lead to a significant...

  5. Deepwater Gulf of Mexico more profitable than previously thought

    International Nuclear Information System (INIS)

    Craig, M.J.K.; Hyde, S.T.

    1997-01-01

    Economic evaluations and recent experience show that the deepwater Gulf of Mexico (GOM) is much more profitable than previously thought. Four factors contributing to the changed viewpoint are: First, deepwater reservoirs have proved to have excellent productive capacity, distribution, and continuity when compared to correlative-age shelf deltaic sands. Second, improved technologies and lower perceived risks have lowered the cost of floating production systems (FPSs). Third, projects now get on-line quicker. Fourth, a collection of other important factors are: Reduced geologic risk and associated high success rates for deepwater GOM wells due primarily to improved seismic imaging and processing tools (3D, AVO, etc.); absence of any political risk in the deepwater GOM (common overseas, and very significant in some international areas); and positive impact of deepwater federal royalty relief. This article uses hypothetical reserve distributions and price forecasts to illustrate indicative economics of deepwater prospects. Economics of Shell Oil Co.'s three deepwater projects are also discussed

  6. Impact of parasitic thermal effects on thermoelectric property measurements by Harman method

    International Nuclear Information System (INIS)

    Kwon, Beomjin; Baek, Seung-Hyub; Keun Kim, Seong; Kim, Jin-Sang

    2014-01-01

    Harman method is a rapid and simple technique to measure thermoelectric properties. However, its validity has been often questioned due to the over-simplified assumptions that this method relies on. Here, we quantitatively investigate the influence of the previously ignored parasitic thermal effects on the Harman method and develop a method to determine an intrinsic ZT. We expand the original Harman relation with three extra terms: heat losses via both the lead wires and radiation, and Joule heating within the sample. Based on the expanded Harman relation, we use differential measurement of the sample geometry to measure the intrinsic ZT. To separately evaluate the parasitic terms, the measured ZTs with systematically varied sample geometries and the lead wire types are fitted to the expanded relation. A huge discrepancy (∼28%) of the measured ZTs depending on the measurement configuration is observed. We are able to separately evaluate those parasitic terms. This work will help to evaluate the intrinsic thermoelectric property with Harman method by eliminating ambiguities coming from extrinsic effects

  7. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  8. Evaluation of impedance on biological Tissues using automatic control measurement system

    International Nuclear Information System (INIS)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo; Lee, Moo Seok; Kim, Sang Sik; Kim, Gun FDo; Lee, Jong Kyu

    2015-01-01

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  9. Description and Evaluation of a Measurement Technique for Assessment of Performing Gender

    Science.gov (United States)

    Harris, Kathleen Mullan; Halpern, Carolyn Tucker

    2016-01-01

    The influence of masculinity and femininity on behaviors and outcomes has been extensively studied in social science research using various measurement strategies. In the present paper, we describe and evaluate a measurement technique that uses existing survey items to capture the extent to which an individual behaves similarly to their same-gender peers. We use data from the first four waves of The National Longitudinal Study of Adolescent to Adult Health (Add Health), a nationally representative sample of adolescents (age 12–18) in the United States who were re-interviewed at ages 13–19, 18–26, and 24–32. We estimate split-half reliability and provide evidence that supports the validity of this measurement technique. We demonstrate that the resulting measure does not perform as a trait measure and is associated with involvement in violent fights, a pattern consistent with theory and empirical findings. This measurement technique represents a novel approach for gender researchers with the potential for expanding our current knowledge base. PMID:28630528

  10. Safety climate and attitude as evaluation measures of organizational safety.

    Science.gov (United States)

    Isla Díaz, R; Díaz Cabrera, D

    1997-09-01

    The main aim of this research is to develop a set of evaluation measures for safety attitudes and safety climate. Specifically it is intended: (a) to test the instruments; (b) to identify the essential dimensions of the safety climate in the airport ground handling companies; (c) to assess the quality of the differences in the safety climate for each company and its relation to the accident rate; (d) to analyse the relationship between attitudes and safety climate; and (e) to evaluate the influences of situational and personal factors on both safety climate and attitude. The study sample consisted of 166 subjects from three airport companies. Specifically, this research was centered on ground handling departments. The factor analysis of the safety climate instrument resulted in six factors which explained 69.8% of the total variance. We found significant differences in safety attitudes and climate in relation to type of enterprise.

  11. Using the SIMGRO regional hydrological model to evaluate salinity control measures in an irrigation area

    NARCIS (Netherlands)

    Kupper, E.; Querner, E.P.; Morábito, J.A.; Menenti, M.

    2002-01-01

    In irrigated areas with drainage and an important interaction with the groundwater system, it is often difficult to predict effects of measures to control salinity. Therefore, in order to evaluate measures to control salinity the SIMGRO integrated regional hydrological model was extended with a

  12. Clinical evaluation of postural posture of patients with previous stroke subjected to early rehabilitation

    Directory of Open Access Journals (Sweden)

    Anna Sagan

    2018-02-01

    Full Text Available Introduction: Impairment disorders are often found in patients with stroke and impairment of motor and cognitive functions. This is a very serious complication because, by imposing a motor impairment, it aggravates the condition of disability and makes it difficult to conduct physical rehabilitation.The resulting neurological deficits due to stroke determine functional disorders. The possibility of locomotion is usually compromised, therefore the risk of falls increases significantly. The aim of the work is to present Postural Assesment Scale for Strock PASS with the postural stroke assessment scale, the impact of early rehabilitation of patients staying in the neurology ward.Material and methods: Postural examination was carried out among 17 people, of which 8 were women, and 9 were male. The study was divided into two stages. The first stage occurred immediately after the stroke and the second one before the patient was discharged from the ward. Research was carried out at the Biegański Specialist Hospital in Grudziądz in the Department of Neurology and Clinical Neuroimmunology and Impact Department.Conclusions: The results of the postural studies carried out in people with previous stroke subjected to early physiotherapy have a beneficial effect of the conducted therapy. There are positive changes between the first and the final examination of the patients.

  13. EM-Measurements and Evaluation of the XRP (Roman Pot to be installed with UA9 Experiment)

    CERN Document Server

    Farricker, Aaron; Sunar, Ezgi; Vollinger, Christine; CERN. Geneva. ATS Department

    2017-01-01

    This note discusses the EM measurements and the impedance evaluation carried out on the XRP-experimental roman pot to complement the installation of the UA9 Experiment in the SPS for studies with a double-crystal setup (ECR SPS-TECS-EC-0001) implemented in 2017. The aim of these measurements was to identify intrinsic resonances that are to be evaluated for their contribution to the longitudinal beam impedance of the machine and to benchmark the simulation model.

  14. Measuring quality of care: considering conceptual approaches to quality indicator development and evaluation.

    Science.gov (United States)

    Stelfox, Henry T; Straus, Sharon E

    2013-12-01

    In this article, we describe one approach for developing and evaluating quality indicators. We focus on describing different conceptual approaches to quality indicator development, review one approach for developing quality indicators, outline how to evaluate quality indicators once developed, and discuss quality indicator maintenance. The key steps for developing quality indicators include specifying a clear goal for the indicators; using methodologies to incorporate evidence, expertise, and patient perspectives; and considering contextual factors and logistics of implementation. The Strategic Framework Board and the National Quality Measure Clearinghouse have developed criteria for evaluating quality indicators that complement traditional psychometric evaluations. Optimal strategies for quality indicator maintenance and dissemination have not been determined, but experiences with clinical guideline maintenance may be informative. For quality indicators to effectively guide quality improvement efforts, they must be developed, evaluated, maintained, and implemented using rigorous evidence-informed practices. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. EXTRAPOLATION TECHNIQUES EVALUATING 24 HOURS OF AVERAGE ELECTROMAGNETIC FIELD EMITTED BY RADIO BASE STATION INSTALLATIONS: SPECTRUM ANALYZER MEASUREMENTS OF LTE AND UMTS SIGNALS.

    Science.gov (United States)

    Mossetti, Stefano; de Bartolo, Daniela; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina; Nava, Elisa

    2017-04-01

    International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A discussion of techniques used in defining the Interactive Measurement Evaluation and Control System at Rocky Flats

    International Nuclear Information System (INIS)

    Greer, B.K.; Hunt, V.; Schweitzer, M.F.

    1983-01-01

    This paper describes both the general methodology used to study the current needs for a measurement control and evaluation system at Rocky Flats Plant and the recommendations for implementation into the Interactive Measurement Evaluation and Control System (IMECS). The study resulted in a clear assessment of the current system and recommendations for the system which will be its replacement. To arrive at the recommendations, the authors used a formal analysis approach that is based on an in-depth study of the measurement evaluation and control problems and user needs. The problems and needs were defined by interviews with present and potential users of this kind of system throughout the nuclear industry. Some of the recommendations are to provide: timely sample measurement feedback; representative measurement error estimates; a history data base of sample measurements To meet the user needs, the new system will: be interactive with user selection menus; use standards which cover the range of application; facilitate historical analysis of sample data and bookkeeping. The implementation of this program is projected to be more cost effective than the current program. Also included are the authors' recommendations to those involved in the design of a system of similar large magnitude

  17. An Evaluation of pectus excavatum by means of body surface measurements on chest CT scans

    International Nuclear Information System (INIS)

    Hirotani, Taichi; Ohama, Kazunori; Shimotake, Takashi; Ishikawa, Nobuki; Watanabe, Reiji

    2009-01-01

    The aim of this study is to determine whether the body surface index replaces the Haller index in order to evaluate the severity of pectus excavatum. Sixty-nine cases with a diagnosis of pectus excavatum between August 2001 and January 2008 were prospectively enrolled in the study. The anterior-posterior chest dimension, lateral chest dimension and depth of the most profound depressed area were measured. The body surface index was expressed as an equation A/(B-C), where A was the transverse diameter, B was the anterior-posterior diameter and C was the depth of the depressed area. This index was compared to the Haller index in each patient. In this study, each value was measured on a chest CT scan. The body surface index significantly correlated with the Haller index, in which the coefficient of correlation was 0.879 (p<0.01). The body surface index corresponding to Haller index 3.25 seems to be 1.67. We could find the body surface index corresponding to each Haller index. We propose that an evaluation of pectus excavatum by means of body surface measurements is clinically useful, and may replace the Haller index. The body surface index may allow us to assess the severity of pectus excavatum without a CT scan, resulting in a reduction of radiation exposure for children with pectus excavatum. It's possible to evaluate the body surface index by using a relational table between this index and the Hailer index. We'll evaluate the body surface index by using values measured on a real body. (author)

  18. Parental self-efficacy and its measurement - an evaluation of a parental self-efficacy measurement scale.

    Science.gov (United States)

    Purssell, Edward; While, Alison

    2013-05-01

    To field test a parental self-efficacy scale regarding its acceptability and feasibility and to describe parental self-efficacy in a convenience sample of parents with children aged 6 years old or less. Self-care within families is increasingly emphasised in health policy as a means of maximising healthcare resources. This study reports the field testing of a scale designed to measure parental self-efficacy. Cross-sectional survey of parents of children aged 6 years old or less. Subjects were recruited through a parenting internet website (n = 84) and local parenting and community organisations (n = 68) and asked to complete a questionnaire containing the scale. Data collection took place between January and August 2011. The scale, previously validated with an expert panel of professionals, gathered information about parental self-efficacy when administered either directly or through an on-line data collection portal, although there were more missing data when administered via the Internet. Although convenience and self-selecting samples precluded parameter estimation, areas of concern highlighted were difficulties differentiating children with serious illnesses and the use of the Personal Child Health Record. Use of the Internet was widespread, as was use of community pharmacists and nursery staff. Although the primary purpose was not to collect specific data, the data indicated the continuing concern of parents regarding serious illness and where additional investment may be required to meet parental needs and expectations. The previously validated scale can be used to collect information about parental self-efficacy either through a paper questionnaire or the Internet. Although there was slightly more missing data from the Internet version, the ease of its administration makes this an attractive option. Parents generally reported high levels of self-efficacy and satisfaction with services; however, the scale was able to identify areas where further investment

  19. Psychometric Properties of Patient-Facing eHealth Evaluation Measures: Systematic Review and Analysis.

    Science.gov (United States)

    Wakefield, Bonnie J; Turvey, Carolyn L; Nazi, Kim M; Holman, John E; Hogan, Timothy P; Shimada, Stephanie L; Kennedy, Diana R

    2017-10-11

    Significant resources are being invested into eHealth technology to improve health care. Few resources have focused on evaluating the impact of use on patient outcomes A standardized set of metrics used across health systems and research will enable aggregation of data to inform improved implementation, clinical practice, and ultimately health outcomes associated with use of patient-facing eHealth technologies. The objective of this project was to conduct a systematic review to (1) identify existing instruments for eHealth research and implementation evaluation from the patient's point of view, (2) characterize measurement components, and (3) assess psychometrics. Concepts from existing models and published studies of technology use and adoption were identified and used to inform a search strategy. Search terms were broadly categorized as platforms (eg, email), measurement (eg, survey), function/information use (eg, self-management), health care occupations (eg, nurse), and eHealth/telemedicine (eg, mHealth). A computerized database search was conducted through June 2014. Included articles (1) described development of an instrument, or (2) used an instrument that could be traced back to its original publication, or (3) modified an instrument, and (4) with full text in English language, and (5) focused on the patient perspective on technology, including patient preferences and satisfaction, engagement with technology, usability, competency and fluency with technology, computer literacy, and trust in and acceptance of technology. The review was limited to instruments that reported at least one psychometric property. Excluded were investigator-developed measures, disease-specific assessments delivered via technology or telephone (eg, a cancer-coping measure delivered via computer survey), and measures focused primarily on clinician use (eg, the electronic health record). The search strategy yielded 47,320 articles. Following elimination of duplicates and non

  20. Effectiveness of sound therapy in patients with tinnitus resistant to previous treatments: importance of adjustments

    Directory of Open Access Journals (Sweden)

    Flavia Alencar de Barros Suzuki

    Full Text Available ABSTRACT INTRODUCTION: The difficulty in choosing the appropriate therapy for chronic tinnitus relates to the variable impact on the quality of life of affected patients and, thus, requires individualization of treatment. OBJECTIVE: To evaluate the effectiveness of using sound generators with individual adjustments to relieve tinnitus in patients unresponsive to previous treatments. METHODS: A prospective study of 10 patients with chronic tinnitus who were unresponsive to previous drug treatments, five males and five females, with ages ranging from 41 to 78 years. Bilateral sound generators (Reach 62 or Mind 9 models were used daily for at least 6 h during 18 months. The patients were evaluated at the beginning, after 1 month and at each 3 months until 18 months through acuphenometry, minimum masking level, the Tinnitus Handicap Inventory, visual analog scale, and the Hospital Anxiety and Depression Scale. The sound generators were adjusted at each visit. RESULTS: There was a reduction of Tinnitus Handicap Inventory in nine patients using a protocol with a customized approach, independent of psychoacoustic characteristics of tinnitus. The best response to treatment occurred in those with whistle-type tinnitus. A correlation among the adjustments and tinnitus loudness and minimum masking level was found. Only one patient, who had indication of depression by Hospital Anxiety and Depression Scale, did not respond to sound therapy. CONCLUSION: There was improvement in quality of life (Tinnitus Handicap Inventory, with good response to sound therapy using customized settings in patients who did not respond to previous treatments for tinnitus.

  1. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure.

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56-30.80) mm, corneal diameter was 14.71±1.07 (13.0-16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9-1.0), and IOP was 39.5±5.7 (30-55) mmHg. The mean follow-up time was 18.29±10.96 (5-44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pvalve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications.

  2. Technology development for evaluation of operational quantities and measurement standard in radiation protection

    International Nuclear Information System (INIS)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Chung, K. K.; Lee, J. I.; Park, T. S.; Ha, S. H.; Oh, P. J.; Jun, K. J.

    1999-03-01

    A study on the fabrication of a new personal thermo-luminescence dosimeter, which can evaluate the personal dose equivalent H p (d), has been performed. Optimum conditions for fabrications of a LiF:Mg, Cu, Na, Si TL phosphor powder has been determined and a disc type TL pellet has been fabricated from this TL powder. Another type of CaSO 4 :Dy, Mo TL material has been also fabricated. These two TL materials have shown greater TL sensitivity than the foreign-made commercial TL materials. Mono-energetic florescence X-rays from 8.6 response have been constructed and evaluated for the performance of the purity, air kerma, beam uniformity and distribution,and scattered fraction of X-rays. A free-air ionization chamber for the absolute measurement of air kerma in medium X-ray has been designed and constructed. Experimental results showed that the homemade chamber leaves nothing to be desired, compared with the national standard chambers in other advanced countries. Gas proportional counting system has been designed and constructed for absolute activity measurements of gaseous radionuclides. Unattached fractions of radon progeny were evaluated in the characteristic study on the detection of radon progeny

  3. Technology development for evaluation of operational quantities and measurement standard in radiation protection

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Chung, K. K.; Lee, J. I.; Park, T. S.; Ha, S. H.; Oh, P. J.; Jun, K. J

    1999-03-01

    A study on the fabrication of a new personal thermo-luminescence dosimeter, which can evaluate the personal dose equivalent H{sub p}(d), has been performed. Optimum conditions for fabrications of a LiF:Mg, Cu, Na, Si TL phosphor powder has been determined and a disc type TL pellet has been fabricated from this TL powder. Another type of CaSO{sub 4}:Dy, Mo TL material has been also fabricated. These two TL materials have shown greater TL sensitivity than the foreign-made commercial TL materials. Mono-energetic florescence X-rays from 8.6 response have been constructed and evaluated for the performance of the purity, air kerma, beam uniformity and distribution,and scattered fraction of X-rays.A free-air ionization chamber for the absolute measurement of air kerma in medium X-ray has been designed and constructed. Experimental results showed that the homemade chamber leaves nothing to be desired, compared with the national standard chambers in other advanced countries. Gas proportional counting system has been designed and constructed for absolute activity measurements of gaseous radionuclides. Unattached fractions of radon progeny were evaluated in the characteristic study on the detection of radon progeny.

  4. Animal models for the evaluation of radiopharmaceuticals to measure brian blood flow and function

    International Nuclear Information System (INIS)

    Welch, M.J.; Marshall, L.G.I.; Mathias, C.J.

    1987-01-01

    Several techniques have been utilized to carry out initial evaluation of radiopharmaceuticals labeled with technetium-99m and other radionuclides. The simplest technique is to measure the amount of radioactivity in the brain in rats or mice following the intravenous administration of these compounds; brain uptake and washout of radiopharmaceuticals can be estimated. More sophisticated techniques involve measuring the uptake and egress of the radiopharmaceutical following carotid artery administration in rats of primates. The Oldendorf technique compares a tracer with a standard compound e.g. tritiated water, to measure the brain uptake index of various compounds determined by decapiation at short times following administration. Another technique in which consecutive administrations of the compound to be studied and oxygen-15-labeled water are injected via the carotid artery of primates; the brain extraction and washout of the unknown tracer can be evaluated. The blood flow can be varied by altering the pCO 2 of the animal. Examples will be given and techniques compared

  5. Tails from previous exposures: a general problem in setting reference levels for the assessment of internal contamination

    International Nuclear Information System (INIS)

    Breuer, F.; Frittelli, L.

    1988-01-01

    Reference levels for retention and excretion are evaluated for routine and special monitoring following the intake of a fraction of ICRP annual limits (ALIs) or of a unit activity. Methodologies are also suggested for taking into account the contribution by previous intakes to excretion or retention

  6. Upon Further Review: V. An Examination of Previous Lightcurve Analysis from the Palmer Divide Observatory

    Science.gov (United States)

    Warner, Brian D.

    2011-01-01

    Updated results are given for nine asteroids previously reported from the Palmer Divide Observatory (PDO). The original images were re-measured to obtain new data sets using the latest version of MPO Canopus photometry software, analysis tools, and revised techniques for linking multiple observing runs covering several days to several weeks. Results that were previously not reported or were moderately different were found for 1659 Punkajarju, 1719 Jens, 1987 Kaplan, 2105 Gudy, 2961 Katsurahama, 3285 Ruth Wolfe, 3447 Burckhalter, 7816 Hanoi, and (34817) 2000 SE116. This is one in a series of papers that will examine results obtained during the initial years of the asteroid lightcurve program at PDO.

  7. Development of nondestructive measurement of cold work rate, (2)

    International Nuclear Information System (INIS)

    Kamimura, Hideaki; Igarashi, Miyuki; Satoh, Masakazu; Miura, Makoto

    1978-01-01

    Cold-worked type 316 stainless steel will be used as fuel cladding material for the proto-type fast reactor MONJU. Cold work rate is an important parameter in swelling behavior of fuel cladding. It has been shown that austenitic stainless steel undergoes martensitic transformation during cold working. Nondestructive evaluation of cold work rate will be expected by measuring residual magnetism produced in the presence of martensitic phase when cold worked austenitic stainless steel is magnetized. In the previous work, the residual magnetism of cladding tubes of type 316 stainless steel was measured. The results have shown high degree of the correlation between residual magnetism and cold work rate. This paper reports the results of measurement on cold-rolled type 316 stainless steel plate samples. Dimensions of the specimens are 100 mm long and 3.5 and 7 mm wide. The apparatus and experimental procedures were similar to the previous work. Good agreement was found between the estimated cold work rate obtained in the previous work and that for cold rolled plate specimens. Measurement of residual magnetism in identical direction with magnetization showed smaller dispersion of data as compared with that in transverse direction. The residual magnetism near specimen surface hardly decreased when the surface of specimen was chemically removed. The reason for the comparative decrease in residual magnetism at 10% and 15% cold work rate is not clear. (Wakatsuki, Y.)

  8. Psychometric characteristics of process evaluation measures for a rural school-based childhood obesity prevention study: Louisiana Health.

    Science.gov (United States)

    Newton, Robert L; Thomson, Jessica L; Rau, Kristi K; Ragusa, Shelly A; Sample, Alicia D; Singleton, Nakisha N; Anton, Stephen D; Webber, Larry S; Williamson, Donald A

    2011-01-01

    To evaluate the implementation of intervention components of the Louisiana Health study, which was a multicomponent childhood obesity prevention program conducted in rural schools. Content analysis. Process evaluation assessed implementation in classrooms, gym classes, and cafeterias. Classroom teachers (n  =  232), physical education teachers (n  =  53), food service managers (n  =  33), and trained observers (n  =  9). Five process evaluation measures were created: Physical Education Questionnaire (PEQ), Intervention Questionnaire (IQ), Food Service Manager Questionnaire (FSMQ), Classroom Observation (CO), and School Nutrition Environment Observation (SNEO). Interrater reliability and internal consistency were assessed on all measures. Analysis of variance and χ(2) were used to compare differences across study groups on questionnaires and observations. The PEQ and one subscale from the FSMQ were eliminated because their reliability coefficients fell below acceptable standards. The subscale internal consistencies for the IQ, FSMQ, CO, and SNEO (all Cronbach α > .60) were acceptable. After the initial 4 months of intervention, there was evidence that the Louisiana Health intervention was being implemented as it was designed. In summary, four process evaluation measures were found to be sufficiently reliable and valid for assessing the delivery of various aspects of a school-based obesity prevention program. These process measures could be modified to evaluate the delivery of other similar school-based interventions.

  9. Automatic electromagnetic valve for previous vacuum

    International Nuclear Information System (INIS)

    Granados, C. E.; Martin, F.

    1959-01-01

    A valve which permits the maintenance of an installation vacuum when electric current fails is described. It also lets the air in the previous vacuum bomb to prevent the oil ascending in the vacuum tubes. (Author)

  10. Volume measurement of the leg with the depth camera for quantitative evaluation of edema

    Science.gov (United States)

    Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi

    2017-02-01

    Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.

  11. Oxidative Stress Measures of Lipid and DNA Damage in Human Tears.

    Science.gov (United States)

    Haworth, Kristina M; Chandler, Heather L

    2017-05-01

    We evaluate feasibility and repeatability of measures for lipid peroxidation and DNA oxidation in human tears, as well as relationships between outcome variables, and compared our findings to previously reported methods of evaluation for ocular sun exposure. A total of 50 volunteers were seen for 2 visits 14 ± 2 days apart. Tear samples were collected from the inferior tear meniscus using a glass microcapillary tube. Oxidative stress biomarkers were quantified using enzyme-linked immunosorbent assay (ELISA): lipid peroxidation by measurement of hexanoyl-lysine (HEL) expression; DNA oxidation by measurement of 8-oxo-2'-deoxyguinosone (8OHdG) expression. Descriptive statistics were generated. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement were calculated. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for tear HEL and 8OHdG expression were 17368.02 (±9878.42) nmol/L and 66.13 (±19.99) ng/mL, respectively. Repeatability was found to be acceptable for both HEL and 8OHdG expression. Univariate linear regression supported tear 8OHdG expression and spring season of collection to be predictors of higher tear HEL expression; tear HEL expression was confirmed as a predictor of higher tear 8OHdG expression. We demonstrate feasibility and repeatability of estimating previously unreported tear 8OHdG expression. Seasonal temperature variation and other factors may influence tear lipid peroxidation. Support is demonstrated to suggest lipid damage and DNA damage occur concurrently on the human ocular surface.

  12. The GAENE--Generalized Acceptance of EvolutioN Evaluation: Development of a New Measure of Evolution Acceptance

    Science.gov (United States)

    Smith, Mike U.; Snyder, Scott W.; Devereaux, Randolph S.

    2016-01-01

    The present study reports the development of a brief, quantitative, web-based, psychometrically sound measure--the Generalized Acceptance of EvolutioN Evaluation (GAENE, pronounced "gene") in a format that is useful in large and small groups, in research, and in classroom settings. The measure was designed to measure only evolution…

  13. Measuring Teaching Quality in Higher Education : Assessing the Problem of Selection Bias in Course Evaluations

    OpenAIRE

    Salomons, Anna; Goos, Maarten

    2014-01-01

    Student evaluations of teaching are widely used to measure teaching quality and compare it across different courses, teachers, departments and institutions: as such, they are of increasing importance for teacher promotion decisions as well as student course selection. However, the response on course evaluations is rarely perfect, rendering such uses unwarranted if students who participate in the evaluation are not randomly selected: this paper is the first to investigate this issue. We quanti...

  14. Review and evaluation of performance measures for survival prediction models in external validation settings

    Directory of Open Access Journals (Sweden)

    M. Shafiqur Rahman

    2017-04-01

    Full Text Available Abstract Background When developing a prediction model for survival data it is essential to validate its performance in external validation settings using appropriate performance measures. Although a number of such measures have been proposed, there is only limited guidance regarding their use in the context of model validation. This paper reviewed and evaluated a wide range of performance measures to provide some guidelines for their use in practice. Methods An extensive simulation study based on two clinical datasets was conducted to investigate the performance of the measures in external validation settings. Measures were selected from categories that assess the overall performance, discrimination and calibration of a survival prediction model. Some of these have been modified to allow their use with validation data, and a case study is provided to describe how these measures can be estimated in practice. The measures were evaluated with respect to their robustness to censoring and ease of interpretation. All measures are implemented, or are straightforward to implement, in statistical software. Results Most of the performance measures were reasonably robust to moderate levels of censoring. One exception was Harrell’s concordance measure which tended to increase as censoring increased. Conclusions We recommend that Uno’s concordance measure is used to quantify concordance when there are moderate levels of censoring. Alternatively, Gönen and Heller’s measure could be considered, especially if censoring is very high, but we suggest that the prediction model is re-calibrated first. We also recommend that Royston’s D is routinely reported to assess discrimination since it has an appealing interpretation. The calibration slope is useful for both internal and external validation settings and recommended to report routinely. Our recommendation would be to use any of the predictive accuracy measures and provide the corresponding predictive

  15. Evaluation of the accuracy of panoramic radiography in linear measurements of the jaws

    International Nuclear Information System (INIS)

    Hoseini, S. H.; Bagherpour, A.; Javadian Langaroodi, A.; Ahmadian Yazdi, A.; Safaei, A.

    2011-01-01

    Panoramic radiography has a great place among imaging techniques because of its enormous advantages. One of the characteristics of an ideal imaging technique is to supply precise measurement. The purpose of the current study was to evaluate the accuracy of linear measurements of the jaws on panoramic radiographs. Patients and Methods: In this study, the vertical distances between the metal markers were measured by panoramic radiography in seven sites of two skulls in various head positions. Then the radiographic measurements were compared with the actual values. Results: Eighty three percent of the measurements were underestimated, 8.5% were overestimated on panoramic radiography and 8.5% of the measurements had no difference with the real measurements. Overestimation was not greater than 1 mm. The difference between actual and radiographic measurements was less in the posterior areas and in the mandible . In all head positions, the greatest difference between actual and radiographic measurements occurred in the anterior area. Conclusion: Based on the results of this study, linear measurements on panoramic radiography are more reliable in the posterior areas and may be used in early clinical measurements.

  16. Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

    International Nuclear Information System (INIS)

    Ho, Duc Duy; Hong, Dong Soo; Kim, Jeong Tae

    2010-01-01

    This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified

  17. Evaluation of thermocouple fin effect in cladding surface temperature measurement during film boiling

    International Nuclear Information System (INIS)

    Tsuruta, Takaharu; Fujishiro, Toshio

    1984-01-01

    Thermocouple fin effect on surface temperature measurement of a fuel rod has been studied at elevated wall temperatures under film boiling condition in a reactivity initiated accident (RIA) situation. This paper presents an analytical equation to evaluate temperature drops caused by the thermocouple wires attached to cladding surface. The equation yielded the local temperature drop at measuring point depending on thermocouple diameter, cladding temperature, coolant flow condition and vapor film thickness. The temperature drops by the evaluating equation were shown in cases of free and forced convection conditions. The analytical results were compared with the measured data for various thermocouple sizes, and also with the estimated maximum cladding temperature based on the oxidation layer thickness in the cladding outer surface. It was concluded that the temperature drops at above 1,000 0 C in cladding temperature were around 120 and 150 0 C for 0.2 and 0.3 mm diameter Pt-Pt.Rh thermocouples, respectively, under a stagnant coolant condition. The fin effect increases with the decrease of vapor film thickness such as under forced flow cooling or at near the quenching point. (author)

  18. Application of a system for measuring foot plantar pressure for evaluation of human mobility

    Science.gov (United States)

    Klimiec, Ewa; Jasiewicz, Barbara; Zaraska, Krzysztof; Piekarski, Jacek; Guzdek, Piotr; Kołaszczyński, Grzegorz

    2016-11-01

    The paper presents evaluation of human mobility by gait analysis, carried out in natural conditions (outside laboratory). Foot plantar pressure is measured using a shoe insole with 8 sensors placed in different anatomical zones of the foot, and placed inside a sports footwear. Polarized PVDF foil is used as a sensor material. A wireless transmission system is used to transmit voltage values to the computer. Due to linear relationship between force and transducer voltage, energy released during walking in arbitrary units can be calculated as integral of the square of transducer voltage over time. Gait measurements have been done over the next few days on healthy person during normal walking and slow walking. Performed measurements allow determination of walking speed (number of steps per second), gait rhythm and manner of walking (applying force to inside versus outside part of the sole). It is found that switching from normal to slow walk increases gait energy by 25% while the pressure distribution across the anatomical regions of the foot remains unchanged. The results will be used for developing a programme for evaluation of patients with cardiac failure and future integration of actimetry with pulse and spirometry measurements.

  19. An Objective Measure for the Visual Fidelity of Virtual Reality and the Risks of Falls in a Virtual Environment

    NARCIS (Netherlands)

    Menzies, R.J.; Rogers, S.J.; Phillips, A. M.; Chiarovano, E.; Waele de, C.; Verstraten, F.A.J.; MacDougall, H.

    Despite decades of development of virtual reality (VR) devices and VR’s recent renaissance, it has been difficult to measure these devices’ effectiveness in immersing the observer. Previously, VR devices have been evaluated using subjective measures of presence, but in this paper, we suggest that

  20. Analysis of over 10,000 Cases finds no association between previously reported candidate polymorphisms and ovarian cancer outcome

    DEFF Research Database (Denmark)

    White, Kristin L; Vierkant, Robert A; Fogarty, Zachary C

    2013-01-01

    Ovarian cancer is a leading cause of cancer-related death among women. In an effort to understand contributors to disease outcome, we evaluated single-nucleotide polymorphisms (SNP) previously associated with ovarian cancer recurrence or survival, specifically in angiogenesis, inflammation, mitosis...