WorldWideScience

Sample records for pretransplantation pet status

  1. Pet Ownership and Health Status during Bereavement.

    Science.gov (United States)

    Akiyama, Hiroko; And Others

    1987-01-01

    Investigated impact of pet ownership on the health status of recently widowed urban middle-class women. Findings suggest pet ownership may have a salutary effect on the adjustment of recently widowed women in terms of symptom experiences and proneness to utilization of medication. (Author/KS)

  2. [Pet ownership and health status of pets from immunocompromised children, with emphasis in zoonotic diseases].

    Science.gov (United States)

    Abarca V, Katia; López Del P, Javier; Peña D, Anamaría; López G, J Carlos

    2011-06-01

    To characterize pet ownership and pet health status in families of immunocompromised (IS) children, with emphasis in zoonotic diseases. Families of IS children from two hospitals in Santiago, Chile, were interviewed and their pets were evaluated by veterinary examination, coproparasitologic and skin dermatophytes test. In specific cases, other laboratory tests were performed in IS children or their relatives. 47 out of 70 contacted families had pets, 42 participated in the study. Several risk factors for IS children were observed, as having a turtle as a pet and to clean cat or turtle faeces. Lack of adequate veterinary control, immunizations and deparasitation of pets were observed. Some animals showed zoonotic diseases or agents, as Brucella canis, Cryptosporidium sp, Giardia intestinalis, Toxocara canis and scabies. 44% of dogs had ticks and 37% had fleas, both potential vectors of infections. Our results suggest that policies to provide safer pet contact in IS children are needed.

  3. Current status and future perspective of PET

    International Nuclear Information System (INIS)

    Lee, Myung Chul

    2002-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) detecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had, 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3

  4. Current status and prospects of cardiac PET

    International Nuclear Information System (INIS)

    Yoshida, Katuya

    1999-01-01

    With positron emission tomography (PET), noninvasive measurements of myocardial blood flow and metabolism have now become possible. 1) Myocardial blood flow: We developed a high-resolution PET system for rabbits and showed that myocardial N-13 ammonnia uptake correlated well with flow measure with microspheres. We also demonstrated that a simplified PET protocol using N-13 ammonia or Rb-82 provide noninvasive measurement of coronary flow reserve in dog experiments. This protocol enables to produce estimates of myocardial blood flow in man and that are well correlated with the complex compartment model. 2) Myocardial glucose metabolism: We validated experimentally a simple method to quantify tissue glucose utilization with the brain reference index (BRI) using C-14 deoxyglucose and assessed its clinical feasibility for myocardial PET. 3) Membrane integrity: Loss of cell membrane integrity for trapping the potassium or it's analog is a market of myocardial necrosis/viability. We recently synthetized potassium-38 as a PET tracer and started an experimental study. (author)

  5. Long-term detection of microchimaerism in peripheral blood after pretransplantation blood transfusion

    NARCIS (Netherlands)

    Vervoordeldonk, S. F.; Doumaid, K.; Remmerswaal, E. B.; ten Berge, I. J.; Wilmink, J. M.; de Waal, L. P.; Boog, C. J.

    1998-01-01

    Renal allograft survival is prolonged after pretransplantation blood transfusion. The aim of this study was to test retrospectively the development and persistence of microchimaerism after pretransplantation blood transfusion and to assess whether the type of blood transfusion (partially matched [=

  6. Higher Pretransplantation Hemoglobin A1c Is Associated With Greater Risk of Posttransplant Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Jung-Im Shin

    2017-11-01

    Discussion: Higher pretransplantation HbA1c above 5.4% is independently associated with greater risk of PTDM among kidney transplant recipients. A continuous relationship between pretransplantation HbA1c and risk of PTDM suggests that increased risk starts at HbA1c levels well below current thresholds for prediabetes.

  7. A Study on Mental Health Status and Personality Traits of Pet Owners

    Directory of Open Access Journals (Sweden)

    H Choobineh

    2007-07-01

    Full Text Available Introduction & Objective: Many Iranian families manage to keep pets at home. Examining psychological consequences and personality traits of pet owners is important. The aim of this study was to examine mental health status and personality traits of pet owners. Materials & Methods: In this descriptive study, 612 pet owners (143 cat owners, 162 dog owners, 155 bird owners and 152 other pet owners were asked to complete General Health Questionnaire (GHQ and IPIP Personality Scale from January to December 2006. Results: Bird owners had the highest (234 cases (38.3% and other pet owners had the lowest (129 cases (42.3% mental health problems. In general, 188 cases (30.7% of all groups had mental health problems. 122 cases (20% of them had somatic compliance, 182 cases (29.7% had anxiety, 149 cases (24.3% had social dysfunction and 84 cases (13.7% had depression. Bird owners had significant high level of social dysfunction than other pet owners. With respect to personality traits, dog owners had low level of agreeableness and openness to experience than other groups. Other pet owners had high level of emotional stability than other groups. Conclusion: Contrary to other countries, it seems that having a pet in home enhances the probability of mental disorders in Iran. It is possible that lower mental health persons were keeping pets in Iran. In personality perspectives, dog owners are more disagreeable people and other pet owners are more emotionally stable ones.

  8. PET

    DEFF Research Database (Denmark)

    Mariager, Rasmus Mølgaard; Schmidt, Regin; Heiberg, Morten Rievers

    PET handler om den hemmelige tjenestes arbejde under den kolde krig 1945-1989. Her fortæller Regin Schmidt, Rasmus Mariager og Morten Heiberg om de mest dramatiske og interessante sager fra PET's arkiv. PET er på flere måder en udemokratisk institution, der er sat til at vogte over demokratiet....... Dens virksomhed er skjult for offentligheden, den overvåger borgernes aktiviteter, og den registrerer følsomme personoplysninger. Historien om PET rejser spørgsmålet om, hvad man skal gøre, når befolkningen i et demokrati er kritisk indstillet over for overvågningen af lovlige politiske aktiviteter......, mens myndighederne mener, at det er nødvendigt for at beskytte demokratiet. PET er på en gang en fortælling om konkrete aktioner og begivenheder i PET's arbejde og et stykke Danmarkshistorie. Det handler om overvågning, spioner, politisk ekstremisme og international terrorisme.  ...

  9. Current status of PET imaging in Huntington's disease

    International Nuclear Information System (INIS)

    Pagano, Gennaro; Niccolini, Flavia; Politis, Marios

    2016-01-01

    To review the developments of recent decades and the current status of PET molecular imaging in Huntington's disease (HD). A systematic review of PET studies in HD was performed. The MEDLINE, Web of Science, Cochrane and Scopus databases were searched for articles in all languages published up to 19 August 2015 using the major medical subject heading ''Huntington Disease'' combined with text and key words ''Huntington Disease'', ''Neuroimaging'' and ''PET''. Only peer-reviewed, primary research studies in HD patients and premanifest HD carriers, and studies in which clinical features were described in association with PET neuroimaging results, were included in this review. Reviews, case reports and nonhuman studies were excluded. A total of 54 PET studies were identified and analysed in this review. Brain metabolism ([ 18 F]FDG and [ 15 O]H 2 O), presynaptic ([ 18 F]fluorodopa, [ 11 C]β-CIT and [ 11 C]DTBZ) and postsynaptic ([ 11 C]SCH22390, [ 11 C]FLB457 and [ 11 C]raclopride) dopaminergic function, phosphodiesterases ([ 18 F]JNJ42259152, [ 18 F]MNI-659 and [ 11 C]IMA107), and adenosine ([ 18 F]CPFPX), cannabinoid ([ 18 F]MK-9470), opioid ([ 11 C]diprenorphine) and GABA ([ 11 C]flumazenil) receptors were evaluated as potential biomarkers for monitoring disease progression and for assessing the development and efficacy of novel disease-modifying drugs in premanifest HD carriers and HD patients. PET studies evaluating brain restoration and neuroprotection were also identified and described in detail. Brain metabolism, postsynaptic dopaminergic function and phosphodiesterase 10A levels were proven to be powerful in assessing disease progression. However, no single technique may be currently considered an optimal biomarker and an integrative multimodal imaging approach combining different techniques should be developed for monitoring potential neuroprotective and preventive treatment

  10. Radioligands for PET studies of central benzodiazepine receptors and PK (peripheral benzodiazepine) binding sites -current status

    International Nuclear Information System (INIS)

    Pike, V.W.; Osman, S.; Shah, F.; Turton, D.R.; Waters, S.L.; Crouzel, C.; Nutt, D.J.

    1993-01-01

    The status of the radiochemical development and biological evaluation of radioligands for PET studies of central benzodiazepine (BZ) receptors and the so-called peripheral benzodiazepine binding sites, here discriminated and referred to as PK binding sites, is reviewed against current pharmacological knowledge, indicating those agents with present value and those with future potential. Practical recommendations are given for the preparation of two useful radioligands for PET studies, [N-methyl- 11 C]flumazenil for central BZ receptors, and [N-methyl- 11 C]PK 11195 for PK binding sites. Quality assurance and plasma metabolite analysis are also reviewed for these radioligands and practical recommendations are given on methodology for their performance. (Author)

  11. Pet ownership among homeless youth: associations with mental health, service utilization and housing status.

    Science.gov (United States)

    Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric

    2015-04-01

    As many as 25 % of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer symptoms of depression and loneliness than their non-pet owning peers. Pet ownership was associated with decreased utilization of housing and job-finding services, and decreased likelihood of currently staying in a shelter. These findings elucidate many of the positive benefits of pet ownership for homeless youth, but importantly highlight that pet ownership may negatively impact housing options. Housing and other services must be sensitive to the needs of homeless youth with pets.

  12. Role of preoperative PET-CT in assessing mediastinal and hilar lymph node status in early stage lung cancer

    Directory of Open Access Journals (Sweden)

    Wei-Yang Lin

    2012-05-01

    Conclusion: Integrated PET-CT is a useful tool for predicting the negativity of mediastinal LN status pre-operatively in clinically early stage (Stages I and II lung cancer but may be relatively inaccurate in predicting hilar LN status and largely confounded by false positives caused by inflammatory process.

  13. Prognostisk vaerdi af PET og MRS ved evaluering af cerebral status hos børn

    DEFF Research Database (Denmark)

    Borgwardt, Lise; Danielsen, Else Rubaek; Børch, Klaus

    2002-01-01

    We report a case of a 12-week-old previously normal infant with severe brain damage after an episode of asphyxia during an RS-virus infection. Sub-acute MRI was normal, but new functional techniques, PET (positron emission tomography) and MRS (magnetic resonance spectroscopy) were severely abnorm....... At an outpatient clinic three months later, he had developed microencephaly and the MRI was now severely abnormal. The case shows the importance of using multimodality functional imaging techniques to assess the cerebral status of infants for prognosis and course of treatment....

  14. Current status of PET imaging in Huntington's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pagano, Gennaro; Niccolini, Flavia; Politis, Marios [King' s College London, Neurodegeneration Imaging Group, Department of Basic and Clinical Neuroscience, Maurice Wohl Clinical Neuroscience Institute, Institute of Psychiatry, Psychology and Neuroscience (IoPPN), Camberwell, London (United Kingdom)

    2016-06-15

    To review the developments of recent decades and the current status of PET molecular imaging in Huntington's disease (HD). A systematic review of PET studies in HD was performed. The MEDLINE, Web of Science, Cochrane and Scopus databases were searched for articles in all languages published up to 19 August 2015 using the major medical subject heading ''Huntington Disease'' combined with text and key words ''Huntington Disease'', ''Neuroimaging'' and ''PET''. Only peer-reviewed, primary research studies in HD patients and premanifest HD carriers, and studies in which clinical features were described in association with PET neuroimaging results, were included in this review. Reviews, case reports and nonhuman studies were excluded. A total of 54 PET studies were identified and analysed in this review. Brain metabolism ([{sup 18}F]FDG and [{sup 15}O]H{sub 2}O), presynaptic ([{sup 18}F]fluorodopa, [{sup 11}C]β-CIT and [{sup 11}C]DTBZ) and postsynaptic ([{sup 11}C]SCH22390, [{sup 11}C]FLB457 and [{sup 11}C]raclopride) dopaminergic function, phosphodiesterases ([{sup 18}F]JNJ42259152, [{sup 18}F]MNI-659 and [{sup 11}C]IMA107), and adenosine ([{sup 18}F]CPFPX), cannabinoid ([{sup 18}F]MK-9470), opioid ([{sup 11}C]diprenorphine) and GABA ([{sup 11}C]flumazenil) receptors were evaluated as potential biomarkers for monitoring disease progression and for assessing the development and efficacy of novel disease-modifying drugs in premanifest HD carriers and HD patients. PET studies evaluating brain restoration and neuroprotection were also identified and described in detail. Brain metabolism, postsynaptic dopaminergic function and phosphodiesterase 10A levels were proven to be powerful in assessing disease progression. However, no single technique may be currently considered an optimal biomarker and an integrative multimodal imaging approach combining different techniques should be developed

  15. Pet Ownership among Homeless Youth: Associations with Mental Health, Service Utilization and Housing Status

    OpenAIRE

    Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric

    2015-01-01

    As many as 25% of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer sympto...

  16. Prognosis of Kidney Transplant Recipients With Pretransplantation Malignancy: A Nationwide Population-Based Cohort Study in Taiwan.

    Science.gov (United States)

    Chiu, H-F; Chung, M-C; Chung, C-J; Yu, T-M; Shu, K-H; Wu, M-J

    2016-04-01

    The objective of this study was to evaluate the prognosis of kidney transplant recipients with pretransplantation malignancy and the incidence of recurrent malignancy in kidney transplant recipients using claims data from Taiwan's universal health insurance program. A total of 4350 transplant recipients were retrospectively analyzed. The rates of pretransplantation or recurrent malignancy, which was defined by their inclusion in the catastrophic illness patient registry using the International Classification of Diseases, 9th Revision, were evaluated. Cox proportional hazard regression and Kaplan-Meier curves were used for the analyses. In total, there were 4350 kidney transplant recipients, 52.1% of patients were male, the mean age at transplantation was 45.8 years old, and the percentages of diabetes mellitus, hypertension, hepatitis B viral infection, and hepatitis C viral infection were 14%, 63.2%, 4.2%, and 2.4%, respectively. There were 95 patients (2.2%) with pretransplantation malignancy. The top 3 pretransplantation malignancies, in decreasing order, were urinary tract, kidney, and breast cancers. After kidney transplantation, 10 recipients had recurrent cancer. The overall cancer recurrence rate was 10.5%. These 10 cancers included urothelial carcinoma (n = 5), renal cell carcinoma (n = 3), breast cancer (n = 1), and thyroid cancer (n = 1). Eleven recipients had a secondary cancer. Patients without pretransplantation and post-transplantation malignancy had the best survival. Patients with pretransplantation malignancy had a greater occurrence of cancers and increased mortality regardless of whether or not they had recurrence of cancer. Our results suggest the higher risk of cancer, recurrent or secondary, and mortality after kidney transplantation. Adequate waiting time before transplantation and preventive strategies are strongly suggested in kidney transplant recipients with cancer history. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Current status of PET in breast cancer imaging, staging, and therapy.

    Science.gov (United States)

    Wahl, R L

    2001-07-01

    The exact roles of PET in the imaging management of patients with known or suspected breast cancer are still in evolution. For assessing primary lesions, it is sometimes possible with PET to detect cancers occult on standard methods. This could be useful in high-risk patient populations, but in dense breasts, background FDG uptake is often higher than in women with fatty breasts, making identification of lesions primary breast disease would seem better addressed by biopsy. With a positive predictive value of FDG PET for cancer over 96%, any FDG-avid breast lesion is highly suspicious and merits biopsy. Although PET in theory should be useful for depicting multifocal disease before surgery, the limitations in detecting small lesions in the breast limit the contribution of PET at present. It is most likely that PET will have a greater role in depicting primary breast lesions as dedicated PET imaging devices for the breast evolve. For axillary and internal mammary nodal staging, results with FDG PET are variable. Small nodal metastases setting is not known, nor is there consensus on how identifying internal mammary node metastases will change treatment. Based on the available data, for pT1 breast lesions, PET, if negative, is not an adequate replacement for sentinel node surgery or axillary dissection. Results from the multicenter trial will be of great interest. Clearly PET can stage metastatic disease well. Bone scans with 18F- are exquisitely sensitive for metastases, and FDG is also very good. However, FDG PET can miss some blastic metastases to bone so at present FDG is not capable of excluding the presence of bone metastases. PET seems very well suited to detecting recurrences in soft tissues and the brachial plexus region in particular. The utility of PET in planning the treatment of individual patients appears promising. Although results must be confirmed in larger studies, it appears safe to conclude that failure of a chemotherapy regimen to decrease FDG

  18. Current status and future role of brain PET/MRI in clinical and research settings

    International Nuclear Information System (INIS)

    Werner, P.; Barthel, H.; Sabri, O.; Drzezga, A.

    2015-01-01

    Hybrid PET/MRI systematically offers a complementary combination of two modalities that has often proven itself superior to the single modality approach in the diagnostic work-up of many neurological and psychiatric diseases. Emerging PET tracers, technical advances in multiparametric MRI and obvious workflow advantages may lead to a significant improvement in the diagnosis of dementia disorders, neurooncological diseases, epilepsy and neurovascular diseases using PET/MRI. Moreover, simultaneous PET/MRI is well suited to complex studies of brain function in which fast fluctuations of brain signals (e.g. related to task processing or in response to pharmacological interventions) need to be monitored on multiple levels. Initial simultaneous studies have already demonstrated that these complementary measures of brain function can provide new insights into the functional and structural organization of the brain. (orig.)

  19. Current status and future role of brain PET/MRI in clinical and research settings

    Energy Technology Data Exchange (ETDEWEB)

    Werner, P.; Barthel, H.; Sabri, O. [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Drzezga, A. [University Hospital Cologne, Department of Nuclear Medicine, Koeln (Germany)

    2015-01-09

    Hybrid PET/MRI systematically offers a complementary combination of two modalities that has often proven itself superior to the single modality approach in the diagnostic work-up of many neurological and psychiatric diseases. Emerging PET tracers, technical advances in multiparametric MRI and obvious workflow advantages may lead to a significant improvement in the diagnosis of dementia disorders, neurooncological diseases, epilepsy and neurovascular diseases using PET/MRI. Moreover, simultaneous PET/MRI is well suited to complex studies of brain function in which fast fluctuations of brain signals (e.g. related to task processing or in response to pharmacological interventions) need to be monitored on multiple levels. Initial simultaneous studies have already demonstrated that these complementary measures of brain function can provide new insights into the functional and structural organization of the brain. (orig.)

  20. Pre-Transplantation Blockade of TNF-α-Mediated Oxygen Species Accumulation Protects Hematopoietic Stem Cells.

    Science.gov (United States)

    Ishida, Takashi; Suzuki, Sachie; Lai, Chen-Yi; Yamazaki, Satoshi; Kakuta, Shigeru; Iwakura, Yoichiro; Nojima, Masanori; Takeuchi, Yasuo; Higashihara, Masaaki; Nakauchi, Hiromitsu; Otsu, Makoto

    2017-04-01

    Hematopoietic stem cell (HSC) transplantation (HSCT) for malignancy requires toxic pre-conditioning to maximize anti-tumor effects and donor-HSC engraftment. While this induces bone marrow (BM)-localized inflammation, how this BM environmental change affects transplanted HSCs in vivo remains largely unknown. We here report that, depending on interval between irradiation and HSCT, residence within lethally irradiated recipient BM compromises donor-HSC reconstitution ability. Both in vivo and in vitro we demonstrate that, among inflammatory cytokines, TNF-α plays a role in HSC damage: TNF-α stimulation leads to accumulation of reactive oxygen species (ROS) in highly purified hematopoietic stem/progenitor cells (HSCs/HSPCs). Transplantation of flow-cytometry-sorted murine HSCs reveals damaging effects of accumulated ROS on HSCs. Short-term incubation either with an specific inhibitor of tumor necrosis factor receptor 1 signaling or an antioxidant N-acetyl-L-cysteine (NAC) prevents TNF-α-mediated ROS accumulation in HSCs. Importantly, pre-transplantation exposure to NAC successfully demonstrats protective effects in inflammatory BM on graft-HSCs, exhibiting better reconstitution capability than that of nonprotected control grafts. We thus suggest that in vivo protection of graft-HSCs from BM inflammation is a feasible and attractive approach, which may lead to improved hematopoietic reconstitution kinetics in transplantation with myeloablative conditioning that inevitably causes inflammation in recipient BM. Stem Cells 2017;35:989-1002. © 2016 The Authors STEM CELLS published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  1. Contamination status and accumulation features of persistent organochlorines in pet dogs and cats from Japan

    International Nuclear Information System (INIS)

    Kunisue, Tatsuya; Nakanishi, Shigeyuki; Watanabe, Mafumi; Abe, Takao; Nakatsu, Susumu; Kawauchi, Sakio; Sano, Akihiko; Horii, Akira; Kano, Yasumasa; Tanabe, Shinsuke

    2005-01-01

    Concentrations of persistent organochlorines (OCs) such as polychlorinated dibenzo-p-dioxin (PCDDs), dibenzofurans (PCDFs), biphenyls, dichlorodiphenyltrichloroethane and their metabolites (DDTs), hexachlorocyclohexane isomers, hexachlorobenzene, and chlordane compounds were determined in genital organs of pet dogs and cats and pet foods from Japan. Levels of OCs in dogs were relatively lower than those in cats, while residue levels in their diets were almost similar, implying that accumulation and elimination mechanisms of these contaminants are different between dogs and cats. When bioconcentration factors (BCFs) were estimated from concentrations of OCs in dogs, cats, and their diets, BCFs of all the OCs except PCDD/DFs exceeded 1.0 in cats. On the other hand, in all the dogs, BCFs of DDTs were below 1.0, suggesting that dogs do not bioconcentrate DDTs. Furthermore, BCFs of all the OCs except PCDD/DFs in dogs were notably lower than those in cats, suggesting that dogs have higher metabolic and elimination capacity for these contaminants than cats. When residue levels of OCs in livers, adipose tissue, and genital organs of two pet dogs were examined, hepatic sequestration of PCDD/DFs and oxychlordane was observed. - Pet dogs may have higher metabolic and elimination capacity for organochlorines than pet cats

  2. PET/MRI of central nervous system: current status and future perspective

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhen Lu; Zhang, Long Jiang [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2016-10-15

    Imaging plays an increasingly important role in the early diagnosis, prognosis prediction and therapy response evaluation of central nervous system (CNS) diseases. The newly emerging hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) can perform ''one-stop-shop'' evaluation, including anatomic, functional, biochemical and metabolic information, even at the molecular level, for personalised diagnoses and treatments of CNS diseases. However, there are still several problems to be resolved, such as appropriate PET detectors, attenuation correction and so on. This review will introduce the basic physical principles of PET/MRI and its potential clinical applications in the CNS. We also provide the future perspectives for this field. (orig.)

  3. Post-treatment PET/CT and p16 status for predicting treatment outcomes in locally advanced head and neck cancer after definitive radiation

    Energy Technology Data Exchange (ETDEWEB)

    Awan, Musaddiq J.; Machtay, Mitchell; Yao, Min [Case Western Reserve University and University Hospitals, Department of Radiation Oncology, Cleveland, OH (United States); Lavertu, Pierre; Zender, Chad; Rezaee, Rod; Fowler, Nicole [University Hospitals, Department of Otolaryngology and Head and Neck Surgery, Cleveland, OH (United States); Karapetyan, Lilit; Gibson, Michael [University Hospitals, Department of Medical Oncology, Cleveland, OH (United States); Wasman, Jay [University Hospitals, Department of Pathology, Cleveland, OH (United States); Faulhaber, Peter [University Hospitals, Department of Nuclear Medicine and Radiology, Cleveland, OH (United States)

    2017-06-15

    To retrospectively review post-treatment (post-tx) FDG-PET/CT scans in patients with advanced head and neck squamous cell carcinoma (HNSCC) and known p16 status, treated with definitive (chemo)radiation (RT). A total of 108 eligible patients had N2A or greater HNSCC treated with chemoRT from August 1, 2008, to February 28, 2015, with post-tx PET/CT within 6 months after RT. Kaplan-Meier curves, log-rank statistics, and Cox proportional hazards regression were used for statistical analysis. Median follow-up was 2.38 years. Sixty-eight (63.0%) patients had p16+ and 40 (37.0%) had p16- status. Two-year overall survival and recurrence-free survival were 93.4% and 77.8%, respectively. The negative predictive value (NPV) of PET/CT for local recurrence (LR) was 100%. The NPV for regional recurrence (RR) was 96.5% for all patients, 100% for p16+ patients, and 88.5% for p16- patients. The positive predictive value (PPV) of PET/CT for recurrence was 77.3% for all patients, 50.0% for p16+, and 78.6% for p16-. The PPV for LR was 72.7% for all patients, 50.0% for p16+ patients, and 72.7% for p16- patients. The PPV for RR was 50.0% for all patients, 33% for p16+, and 66.6% for p16-. Post-tx PET/CT and p16 status were independent predictors of recurrence-free survival (p < 0.01). Post-tx PET/CT predicts treatment outcomes in both p16 + and p16- patients, and does so independently of p16 status. P16- patients with negative PET have a 10% risk of nodal recurrence, and closer follow-up in these patients is warranted. (orig.)

  4. Systematic review and meta-analysis on the prognostic value of complete remission status at FDG-PET in Hodgkin lymphoma after completion of first-line therapy

    NARCIS (Netherlands)

    Adams, Hugo J A; Nievelstein, Rutger A J; Kwee, Thomas C.

    This study aimed to systematically review and meta-analyze the prognostic value of complete remission status at 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in Hodgkin lymphoma after completion of first-line therapy. A systematic literature search was performed in the MEDLINE

  5. Pretreatment evaluation of distant-site status in patients with nasopharyngeal carcinoma: accuracy of whole-body MRI at 3-Tesla and FDG-PET-CT

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Chan, Sheng-Chieh; Yen, Tzu-Chen; Chang, Joseph Tung-Chieh; Liao, Chun-Ta; Ko, Sheung-Fat; Wai, Yau-Yau; Wang, Hung-Ming; Wang, Jiun-Jie; Chen, Min-Chi

    2009-01-01

    We sought to prospectively evaluate the accuracy of 3.0-Tesla whole-body magnetic resonance imaging (WB-MRI) and integrated fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (FDG-PET-CT), and their combined interpretation for the assessment of distant-site status in 150 patients with untreated nasopharyngeal carcinoma (NPC). Eighteen (12%) patients were diagnosed as having distant malignancies (15 patients had distant metastases, and three distant synchronous tumours). On a patient-based analysis, WB-MRI and FDG-PET-CT showed similar sensitivity (77.8% vs 72.2%, P > 0.999), specificity (98.5% vs 97.7%, P > 0.999) and diagnostic capability (0.905 vs 0.878, P = 0.669). Combined interpretation of WB-MRI and FDG-PET-CT showed no significant benefit over either technique alone. In conclusion, 3.0-Tesla WB-MRI is a feasible, non-ionising technique that showed similar diagnostic capacity to FDG-PET-CT in assessing distant-site status in patients with untreated NPC and can be recommended as the first-line imaging technique for comprehensive evaluation of such patients. (orig.)

  6. Pretreatment evaluation of distant-site status in patients with nasopharyngeal carcinoma: accuracy of whole-body MRI at 3-Tesla and FDG-PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Shu-Hang [Chang Gung Memorial Hospital, Chang Gung University, Molecular Imaging Center, Taoyuan (China); Chang Gung Memorial Hospital, Chang Gung University, Department of Diagnostic Radiology, Taoyuan (China); Chang Gung Memorial Hospital, Linkou Medical Center, Department of Diagnostic Radiology, Taoyuan (China); Chan, Sheng-Chieh; Yen, Tzu-Chen [Chang Gung Memorial Hospital, Chang Gung University, Molecular Imaging Center, Taoyuan (China); Chang Gung Memorial Hospital, Chang Gung University, Department of Nuclear Medicine, Taoyuan (China); Chang, Joseph Tung-Chieh [Chang Gung Memorial Hospital, Chang Gung University, Department of Radiation Oncology, Taoyuan (China); Liao, Chun-Ta [Chang Gung Memorial Hospital, Chang Gung University, Department of Otorhinolaryngology, Taoyuan (China); Ko, Sheung-Fat; Wai, Yau-Yau [Chang Gung Memorial Hospital, Chang Gung University, Molecular Imaging Center, Taoyuan (China); Chang Gung Memorial Hospital, Chang Gung University, Department of Diagnostic Radiology, Taoyuan (China); Wang, Hung-Ming [Chang Gung Memorial Hospital, Chang Gung University, Department of Medical Oncology, Taoyuan (China); Wang, Jiun-Jie [Chang Gung Memorial Hospital, Chang Gung University, Molecular Imaging Center, Taoyuan (China); Chang Gung Memorial Hospital, Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China); Chen, Min-Chi [Chang Gung Memorial Hospital, Chang Gung University, Department of Public Health and Biostatistics, Taoyuan (China)

    2009-12-15

    We sought to prospectively evaluate the accuracy of 3.0-Tesla whole-body magnetic resonance imaging (WB-MRI) and integrated fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (FDG-PET-CT), and their combined interpretation for the assessment of distant-site status in 150 patients with untreated nasopharyngeal carcinoma (NPC). Eighteen (12%) patients were diagnosed as having distant malignancies (15 patients had distant metastases, and three distant synchronous tumours). On a patient-based analysis, WB-MRI and FDG-PET-CT showed similar sensitivity (77.8% vs 72.2%, P > 0.999), specificity (98.5% vs 97.7%, P > 0.999) and diagnostic capability (0.905 vs 0.878, P = 0.669). Combined interpretation of WB-MRI and FDG-PET-CT showed no significant benefit over either technique alone. In conclusion, 3.0-Tesla WB-MRI is a feasible, non-ionising technique that showed similar diagnostic capacity to FDG-PET-CT in assessing distant-site status in patients with untreated NPC and can be recommended as the first-line imaging technique for comprehensive evaluation of such patients. (orig.)

  7. Role of [18F]FDG PET in prediction of KRAS and EGFR mutation status in patients with advanced non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Caicedo, Carlos; Garcia-Velloso, Maria Jose; Vigil Diaz, Carmen; Richter Echevarria, Jose Angel; Lozano, Maria Dolores; Labiano, Tania; Lopez-Picazo, Jose Maria; Gurpide, Alfonso; Perez Gracia, Jose Luis; Zulueta, Javier

    2014-01-01

    The tumour molecular profile predicts the activity of epidermal growth factor receptor (EGFR) inhibitors in non-small-cell lung cancer (NSCLC). However, tissue availability and tumour heterogeneity limit its assessment. We evaluated whether [ 18 F]FDG PET might help predict KRAS and EFGR mutation status in NSCLC. Between January 2005 and October 2011, 340 NSCLC patients were tested for KRAS and EGFR mutation status. We identified patients with stage III and IV disease who had undergone [ 18 F]FDG PET/CT scanning for initial staging. SUVpeak, SUVmax and SUVmean of the single hottest tumour lesions were calculated, and their association with KRAS and EGFR mutation status was assessed. A receiver operator characteristic (ROC) curve analysis and a multivariate analysis (including SUVmean, gender, age and AJCC stage) were performed to identify the potential value of [ 18 F]FDG PET/CT for predicting KRAS mutation. From 102 patients staged using [ 18 F]FDG PET/CT, 28 (27 %) had KRAS mutation (KRAS+), 22 (22 %) had EGFR mutation (EGFR+) and 52 (51 %) had wild-type KRAS and EGFR profiles (WT). KRAS+ patients showed significantly higher [ 18 F]FDG uptake than EGFR+ and WT patients (SUVmean 9.5, 5.7 and 6.6, respectively; p 18 F]FDG uptake between EGFR+ patients and WT patients. ROC curve analysis for KRAS mutation status discrimination yielded an area under the curve of 0.740 for SUVmean (p 18 F]FDG uptake than WT patients, as assessed in terms of SUVpeak, SUVmax and SUVmean. A multivariate model based on age, gender, AJCC stage and SUVmean might be used as a predictive marker of KRAS mutation status in patients with stage III or IV NSCLC. (orig.)

  8. (89)Zr-mAb3481 PET for HER3 tumor status assessment during lapatinib treatment

    NARCIS (Netherlands)

    Pool, Martin; Kol, Arjan; de Jong, Steven; de Vries, Elisabeth G. E.; Lub-de Hooge, Marjolijn N; Terwisscha van Scheltinga, Anton G T

    2017-01-01

    Treatment of human epidermal growth factor receptor 2 (HER2)-driven breast cancer with tyrosine kinase inhibitor lapatinib can induce a compensatory HER3 increase, which may attenuate antitumor efficacy. Therefore, we explored in vivo HER3 tumor status assessment after lapatinib treatment with

  9. Senior Pets

    Science.gov (United States)

    ... Care Animal Welfare Veterinary Careers Public Health Senior Pets Veterinarians Get the Senior Pets client information brochure . ... healthier life for your pet. When does a pet become “old”? It varies, but cats and small ...

  10. Public health ethics and a status for pets as person-things : revisiting the place of animals in urbanized societies.

    Science.gov (United States)

    Rock, Melanie; Degeling, Chris

    2013-12-01

    Within the field of medical ethics, discussions related to public health have mainly concentrated on issues that are closely tied to research and practice involving technologies and professional services, including vaccination, screening, and insurance coverage. Broader determinants of population health have received less attention, although this situation is rapidly changing. Against this backdrop, our specific contribution to the literature on ethics and law vis-à-vis promoting population health is to open up the ubiquitous presence of pets within cities and towns for further discussion. An expanding body of research suggests that pet animals are deeply relevant to people's health (negatively and positively). Pet bylaws adopted by town and city councils have largely escaped notice, yet they are meaningful to consider in relation to everyday practices, social norms, and cultural values, and thus in relation to population health. Nevertheless, not least because they pivot on defining pets as private property belonging to individual people, pet bylaws raise emotionally charged ethical issues that have yet to be tackled in any of the health research on pet ownership. The literature in moral philosophy on animals is vast, and we do not claim to advance this field here. Rather, we pragmatically seek to reconcile philosophical objections to pet ownership with both animal welfare and public health. In doing so, we foreground theorizations of personhood and property from sociocultural anthropology.

  11. Evaluation of a pet-assisted living intervention for improving functional status in assisted living residents with mild to moderate cognitive impairment: a pilot study.

    Science.gov (United States)

    Friedmann, Erika; Galik, Elizabeth; Thomas, Sue A; Hall, P Sue; Chung, Seon Yoon; McCune, Sandra

    2015-05-01

    In older adults with cognitive impairment (CI), decreased functional status and increased behavioral symptoms require relocation from assisted living (AL) to nursing homes. Studies support positive effects of pets on health/function. Evaluate the effectiveness of the Pet AL (PAL) intervention to support physical, behavioral, and emotional function in AL residents with CI. Cognitively impaired AL residents randomized to 60-90 minute sessions [PAL (n = 22) or reminiscing (n = 18)] twice/week for 12 weeks. PAL interventionist encourages residents to perform skills with the visiting dog; reminiscing interventionist encourages residents to reminisce. Monthly assessment of physical (energy expenditure, activities of daily living), emotional (depression, apathy), and behavioral (agitation) function. In linear mixed models, physical activity depressive symptoms improved more with PAL. Evidence supports that the PAL program helps preserve/enhance function of AL residents with CI. Additional study is required to evaluate the duration and predictors of effectiveness of the PAL intervention. © The Author(s) 2014.

  12. Impact of genome assembly status on ChIP-Seq and ChIP-PET data mapping

    Directory of Open Access Journals (Sweden)

    Sachs Laurent

    2009-12-01

    Full Text Available Abstract Background ChIP-Seq and ChIP-PET can potentially be used with any genome for genome wide profiling of protein-DNA interaction sites. Unfortunately, it is probable that most genome assemblies will never reach the quality of the human genome assembly. Therefore, it remains to be determined whether ChIP-Seq and ChIP-PET are practicable with genome sequences other than a few (e.g. human and mouse. Findings Here, we used in silico simulations to assess the impact of completeness or fragmentation of genome assemblies on ChIP-Seq and ChIP-PET data mapping. Conclusions Most currently published genome assemblies are suitable for mapping the short sequence tags produced by ChIP-Seq or ChIP-PET.

  13. Role of [{sup 18}F]FDG PET in prediction of KRAS and EGFR mutation status in patients with advanced non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Caicedo, Carlos; Garcia-Velloso, Maria Jose; Vigil Diaz, Carmen; Richter Echevarria, Jose Angel [University of Navarra, Nuclear Medicine Department, University Clinic of Navarra, Pamplona (Spain); Lozano, Maria Dolores; Labiano, Tania [University of Navarra, Pathology Department, University Clinic of Navarra, Pamplona (Spain); Lopez-Picazo, Jose Maria; Gurpide, Alfonso; Perez Gracia, Jose Luis [University of Navarra, Oncology Department, University Clinic of Navarra, Pamplona (Spain); Zulueta, Javier [University of Navarra, Pulmonology Department, University Clinic of Navarra, Pamplona (Spain)

    2014-11-15

    The tumour molecular profile predicts the activity of epidermal growth factor receptor (EGFR) inhibitors in non-small-cell lung cancer (NSCLC). However, tissue availability and tumour heterogeneity limit its assessment. We evaluated whether [{sup 18}F]FDG PET might help predict KRAS and EFGR mutation status in NSCLC. Between January 2005 and October 2011, 340 NSCLC patients were tested for KRAS and EGFR mutation status. We identified patients with stage III and IV disease who had undergone [{sup 18}F]FDG PET/CT scanning for initial staging. SUVpeak, SUVmax and SUVmean of the single hottest tumour lesions were calculated, and their association with KRAS and EGFR mutation status was assessed. A receiver operator characteristic (ROC) curve analysis and a multivariate analysis (including SUVmean, gender, age and AJCC stage) were performed to identify the potential value of [{sup 18}F]FDG PET/CT for predicting KRAS mutation. From 102 patients staged using [{sup 18}F]FDG PET/CT, 28 (27 %) had KRAS mutation (KRAS+), 22 (22 %) had EGFR mutation (EGFR+) and 52 (51 %) had wild-type KRAS and EGFR profiles (WT). KRAS+ patients showed significantly higher [{sup 18}F]FDG uptake than EGFR+ and WT patients (SUVmean 9.5, 5.7 and 6.6, respectively; p < 0.001). No significant differences were observed in [{sup 18}F]FDG uptake between EGFR+ patients and WT patients. ROC curve analysis for KRAS mutation status discrimination yielded an area under the curve of 0.740 for SUVmean (p < 0.001). The multivariate analysis showed a sensitivity and specificity of 78.6 % and 62.2 %, respectively, and the AUC was 0.773. NSCLC patients with tumours harbouring KRAS mutations showed significantly higher [{sup 18}F]FDG uptake than WT patients, as assessed in terms of SUVpeak, SUVmax and SUVmean. A multivariate model based on age, gender, AJCC stage and SUVmean might be used as a predictive marker of KRAS mutation status in patients with stage III or IV NSCLC. (orig.)

  14. Associations between pet ownership and self-reported health status in people suffering from chronic fatigue syndrome.

    Science.gov (United States)

    Wells, Deborah L

    2009-04-01

    This study explored the association between pet ownership and self-reported health in people suffering from chronic fatigue syndrome (CFS). One hundred and ninety-three (193) people with medically diagnosed CFS completed a postal survey designed to collect information on illness severity, physical and psychologic health, and pet ownership practices. Most of the participants were female (72.0%), over 45 years of age (57.1%) and married (41.1%) with no children (63.1%). Pets were owned by 58.3% of the sample, with dogs and cats being the most commonly kept types of companion animal. The general health of the participants was discovered to be poor, as assessed by scores on the Chalder Fatigue Questionnaire (CFQ), General Health Questionnaire-12 (GHQ-12), and Short-Form-36 (SF-36) health survey. Pet ownership was not significantly associated with scores on the CFQ, GHQ-12, or SF-36 scales, although pet owners considered their animals to offer them a range of health benefits, notably those associated with mental well-being. Overall, findings suggest no statistically significant association between pet ownership and self-reported health in people with CFS. Nonetheless, people suffering from this condition believe that their pets have the potential to enhance quality of life. Although animals should not be regarded as a panacea for people with long-term conditions such as CFS, they may, nonetheless, serve a valuable, and currently underutilized, role in promoting well-being, whether in their own right, or in conjunction with more traditional forms of therapy.

  15. Static and dynamic18F-FET PET for the characterization of gliomas defined by IDH and 1p/19q status.

    Science.gov (United States)

    Verger, Antoine; Stoffels, Gabriele; Bauer, Elena K; Lohmann, Philipp; Blau, Tobias; Fink, Gereon R; Neumaier, Bernd; Shah, Nadim J; Langen, Karl-Josef; Galldiks, Norbert

    2018-03-01

    The molecular features isocitrate dehydrogenase (IDH) mutation and 1p/19q co-deletion have gained major importance for both glioma typing and prognosis and have, therefore, been integrated in the World Health Organization (WHO) classification in 2016. The aim of this study was to characterize static and dynamic O-(2- 18 F-fluoroethyl)-L-tyrosine ( 18 F-FET) PET parameters in gliomas with or without IDH mutation or 1p/19q co-deletion. Ninety patients with newly diagnosed and untreated gliomas with a static and dynamic 18 F-FET PET scan prior to evaluation of tumor tissue according to the 2016 WHO classification were identified retrospectively. Mean and maximum tumor-to-brain ratios (TBR mean/max ), as well as dynamic parameters (time-to-peak and slope) of 18 F-FET uptake were calculated. Sixteen (18%) oligodendrogliomas (IDH mutated, 1p/19q co-deleted), 27 (30%) astrocytomas (IDH mutated only), and 47 (52%) glioblastomas (IDH wild type only) were identified. TBR mean , TBR max , TTP and slope discriminated between IDH mutated astrocytomas and IDH wild type glioblastomas (P IDH mutated, 1p/19q co-deleted) and glioblastomas or astrocytomas. Furthermore, TBR mean , TBR max , TTP, and slope discriminated between gliomas with and without IDH mutation (p IDH mutation status. However, IDH mutated and 1p/19q co-deleted oligodendrogliomas cannot be differentiated from glioblastomas and astrocytomas by 18 F-FET PET.

  16. Gene transcript analysis blood values correlate with {sup 68}Ga-DOTA-somatostatin analog (SSA) PET/CT imaging in neuroendocrine tumors and can define disease status

    Energy Technology Data Exchange (ETDEWEB)

    Bodei, L. [European Institute of Oncology, Division of Nuclear Medicine, Milan (Italy); Kidd, M.; Modlin, I.M.; Drozdov, I. [Wren Laboratories, Branford, CT (United States); Prasad, V. [Charite University Hospital, Department of Nuclear Medicine, Berlin (Germany); Severi, S.; Paganelli, G. [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS, Nuclear Medicine and Radiometabolic Units, Meldola (Italy); Ambrosini, V. [S. Orsola-Malpighi University Hospital, Nuclear Medicine, Bologna (Italy); Kwekkeboom, D.J.; Krenning, E.P. [Erasmus Medical Center Rotterdam, Nuclear Medicine Department, Rotterdam (Netherlands); Baum, R.P. [Zentralklinik Bad Berka, THERANOSTICS Center for Molecular Radiotherapy and Imaging, Bad Berka (Germany)

    2015-08-15

    Precise determination of neuroendocrine tumor (NET) disease status and response to therapy remains a rate-limiting concern for disease management. This reflects limitations in biomarker specificity and resolution capacity of imaging. In order to evaluate biomarker precision and identify if combinatorial blood molecular markers and imaging could provide added diagnostic value, we assessed the concordance between {sup 68}Ga-somatostatin analog (SSA) positron emission tomography (PET), circulating NET gene transcripts (NETest), chromogranin A (CgA), and Ki-67 in NETs. We utilized two independent patient groups with positive {sup 68}Ga-SSA PET: data set 1 ({sup 68}Ga-SSA PETs undertaken for peptide receptor radionuclide therapy (PRRT), as primary or salvage treatment, n = 27) and data set 2 ({sup 68}Ga-SSA PETs performed in patients referred for initial disease staging or restaging after various therapies, n = 22). We examined the maximum standardized uptake value (SUV{sub max}), circulating gene transcripts, CgA levels, and baseline Ki-67. Regression analyses, generalized linear modeling, and receiver-operating characteristic (ROC) analyses were undertaken to determine the strength of the relationships. SUV{sub max} measured in two centers were mathematically evaluated (regression modeling) and determined to be comparable. Of 49 patients, 47 (96 %) exhibited a positive NETest. Twenty-six (54 %) had elevated CgA (χ{sup 2} = 20.1, p < 2.5 x 10{sup -6}). The majority (78 %) had Ki-67 < 20 %. Gene transcript scores were predictive of imaging with >95 % concordance and significantly correlated with SUV{sub max} (R {sup 2} = 0.31, root-mean-square error = 9.4). The genes MORF4L2 and somatostatin receptors SSTR1, 3, and 5 exhibited the highest correlation with SUV{sub max}. Progressive disease was identified by elevated levels of a quotient of MORF4L2 expression and SUV{sub max} [ROC-derived AUC (R {sup 2} = 0.7, p < 0.05)]. No statistical relationship was identified

  17. Static and dynamic 18F-FET PET for the characterization of gliomas defined by IDH and 1p/19q status

    International Nuclear Information System (INIS)

    Verger, Antoine; Stoffels, Gabriele; Lohmann, Philipp; Neumaier, Bernd; Bauer, Elena K.; Blau, Tobias; Fink, Gereon R.; Shah, Nadim J.; Langen, Karl-Josef; Galldiks, Norbert

    2018-01-01

    The molecular features isocitrate dehydrogenase (IDH) mutation and 1p/19q co-deletion have gained major importance for both glioma typing and prognosis and have, therefore, been integrated in the World Health Organization (WHO) classification in 2016. The aim of this study was to characterize static and dynamic O-(2- 18 F-fluoroethyl)-L-tyrosine ( 18 F-FET) PET parameters in gliomas with or without IDH mutation or 1p/19q co-deletion. Ninety patients with newly diagnosed and untreated gliomas with a static and dynamic 18 F-FET PET scan prior to evaluation of tumor tissue according to the 2016 WHO classification were identified retrospectively. Mean and maximum tumor-to-brain ratios (TBR mean/max ), as well as dynamic parameters (time-to-peak and slope) of 18 F-FET uptake were calculated. Sixteen (18%) oligodendrogliomas (IDH mutated, 1p/19q co-deleted), 27 (30%) astrocytomas (IDH mutated only), and 47 (52%) glioblastomas (IDH wild type only) were identified. TBR mean , TBR max , TTP and slope discriminated between IDH mutated astrocytomas and IDH wild type glioblastomas (P < 0.01). TBR mean showed the best diagnostic performance (cut-off 1.95; sensitivity, 89%; specificity, 67%; accuracy, 81%). None of the parameters discriminated between oligodendrogliomas (IDH mutated, 1p/19q co-deleted) and glioblastomas or astrocytomas. Furthermore, TBR mean , TBR max , TTP, and slope discriminated between gliomas with and without IDH mutation (p < 0.01). The best diagnostic performance was obtained for the combination of TTP with TBR max or slope (accuracy, 73%). Data suggest that static and dynamic 18 F-FET PET parameters may allow determining non-invasively the IDH mutation status. However, IDH mutated and 1p/19q co-deleted oligodendrogliomas cannot be differentiated from glioblastomas and astrocytomas by 18 F-FET PET. (orig.)

  18. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  19. Comparative diagnostic performance of {sup 18}F-FDG PET/CT versus whole-body MRI for determination of remission status in multiple myeloma after stem cell transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Derlin, Thorsten; Peldschus, Kersten; Bannas, Peter; Herrmann, Jochen; Habermann, Christian R.; Adam, Gerhard; Weber, Christoph [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Muenster, Silvia [University Medical Center Hamburg-Eppendorf, Department of Nuclear Medicine, Hamburg (Germany); Stuebig, Thomas; Kroeger, Nicolaus [University Medical Center Hamburg-Eppendorf, Clinic for Stem Cell Transplantation, Hamburg (Germany)

    2013-02-15

    To compare the diagnostic performance of whole-body magnetic resonance imaging (WBMRI) versus {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) for determination of remission status in patients with multiple myeloma (MM) after stem cell transplantation (SCT). Thirty-one patients were examined by both WBMRI and PET/CT after SCT. Imaging results and clinical remission status as determined by the clinical gold standard (Uniform Response Criteria) were compared. One hundred four lesions were detected in 21 patients. PET/CT had a sensitivity of 50.0 %, a specificity of 85.7 %, a positive predictive value of 62.5 %, a negative predictive value of 78.3 %, and an overall accuracy of 74.2 % for determination of remission status. MRI had a sensitivity of 80.0 %, a specificity of 38.1 %, a positive predictive value of 38.1 %, a negative predictive value of 80 %, and an overall accuracy of 51.6 %. Concordant results were observed in only 12 (11.5 %) of the 104 lesions. In the post-treatment setting, both FDG PET/CT and WBMRI provide information about the extent of disease, allowing for a more comprehensive evaluation of persisting or recurrent myeloma. MRI may often be false positive because of persistent non-viable lesions. Therefore, PET/CT might be more suitable than MRI for determination of remission status. (orig.)

  20. Autologous Stem Cell Transplantation for Follicular Lymphoma: Favorable Long-Term Survival Irrespective of Pretransplantation Rituximab Exposure.

    Science.gov (United States)

    Jiménez-Ubieto, Ana; Grande, Carlos; Caballero, Dolores; Yáñez, Lucrecia; Novelli, Silvana; Hernández-Garcia, Miguel Teodoro; Manzanares, María; Arranz, Reyes; Ferreiro, José Javier; Bobillo, Sabella; Mercadal, Santiago; Galeo, Andrea; López Jiménez, Javier; Moraleda, José María; Vallejo, Carlos; Albo, Carmen; Pérez, Elena; Marrero, Carmen; Magnano, Laura; Palomera, Luis; Jarque, Isidro; Martínez-Sánchez, Pilar; Martín, Alejandro; Coria, Erika; López-Guillermo, Armando; Salar, Antonio; Lahuerta, Juan José

    2017-10-01

    of especial interest in pretransplantation rituximab-sensitive patients with FL. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  1. Current status of PET imaging of neuroendocrine tumours ([18F]FDOPA, [68Ga]tracers, [11C]/[18F]-HTP).

    Science.gov (United States)

    Ambrosini, V; Morigi, J J; Nanni, C; Castellucci, P; Fanti, S

    2015-03-01

    Neuroendocrine neoplasms (NEN) functional imaging is an evolving field that witnessed major advances in the past two decades. The routine use of PET/CT with an array of new radiotracers to specifically study NEN resulted in an increase in lesions detection. Currently, PET radiopharmaceuticals for NEN imaging include both metabolic ([18F]DOPA, [18F]FDG, [11C]/[18F]-HTP) and receptor-mediated compounds ([68Ga]DOTA-peptides). Discussion is still on-going regarding the clinical setting that may benefit the most from the use of one tracer over the other. [68Ga]DOTA-peptides are accurate for the detection of well differentiated NEN and are increasingly employed. Moreover, providing data on somatostatin receptors expression on NEN cells, they represent a fundamental procedure to be performed before starting therapy, as well as to guide treatment, with either hot or cold somatostatin analogues. The easy and economic synthesis process also favours their clinical employment even in centres without an on-site cyclotron. [18F]DOPA is accurate for studying well differentiated tumours however the difficult and expensive synthesis have limited its clinical employment. It currently can be successfully used for imaging tumours with variable to low expression of SSR (medullary thyroid carcinoma, neuroblastoma, pheocromocytoma), that cannot be accurately studied with [68Ga]DOTA-peptides. [11C]/[18F]-HTP has also been proposed to image well differentiated NEN, on the basis of serotonin pathway activity, for which [11C]/[18F]-HTP can be used as precursor. However, although preliminary data are encouraging, the feasibility of its widespread clinical use is still under discussion, mainly limited by a complex synthesis process and more proven advantages over other currently employed compounds. This review aims to provide an overview of the current status and clinical application of PET tracers to image well differentiated NEN and to focus on the still open-issues of debate.

  2. Current status of PET imaging of neuroendocrine tumours ([18F]FDOPA, [68Ga]traces, [11C/[18F]-HTP)

    International Nuclear Information System (INIS)

    Ambrosini, A.; Morgini, J.J.; Nanni, C.; Castellucci, P.; Fanti, S.

    2015-01-01

    Neuroendocrine neoplasms (NEN) functional imaging is an evolving field that witnessed major advances in the past two decades. The routine use of PET/CT with an array of new radiotracers to specifically study NEN resulted in an increase in lesions detection. Currently, PET radiopharmaceuticals for NEN imaging include both metabolic ([18F]DOPA, [18F]FDG, [11C]/[18F]-HTP) and receptor-mediated compounds ([68Ga]DOTA-peptides). Discussion is still on-going regarding the clinical setting that may benefit the most from the use of one tracer over the other. [68Ga]DOTA-peptides are accurate for the detection of well differentiated NEN and are increasingly employed. Moreover, providing data on somatostatin receptors expression on NEN cells, they represent a fundamental procedure to be performed before starting therapy, as well as to guide treatment, with either hot or cold somatostatin analogues. The easy and economic synthesis process also favours their clinical employment even in centres without an on-site cyclotron. [18F]DOPA is accurate for studying well differentiated tumours however the difficult and expensive synthesis have limited its clinical employment. It currently can be successfully used for imaging tumours with variable to low expression of SSR (medullary thyroid carcinoma, neuroblastoma, pheocromocytoma), that cannot be accurately studied with [68Ga]DOTA-peptides. [11C]/[18F]-HTP has also been proposed to image well differentiated NEN, on the basis of serotonin pathway activity, for which [11C]/[18F]-HTP can be used as precursor. However, although preliminary data are encouraging, the feasibility of its widespread clinical use is still under discussion, mainly limited by a complex synthesis process and more proven advantages over other currently employed compounds. This review aims to provide an overview of the current status and clinical application of PET tracers to image well differentiated NEN and to focus on the still open-issues of debate

  3. Biological tumour volumes of gliomas in early and standard 20-40 min18F-FET PET images differ according to IDH mutation status.

    Science.gov (United States)

    Unterrrainer, M; Winkelmann, I; Suchorska, B; Giese, A; Wenter, V; Kreth, F W; Herms, J; Bartenstein, P; Tonn, J C; Albert, N L

    2018-02-27

    For the clinical evaluation of O-(2- 18 F-fluoroethyl)-L-tyrosine ( 18 F-FET) PET images, the use of standard summation images obtained 20-40 min after injection is recommended. However, early summation images obtained 5-15 min after injection have been reported to allow better differentiation between low-grade glioma (LGG) and high-grade glioma (HGG) by capturing the early 18 F-FET uptake peak specific for HGG. We compared early and standard summation images with regard to delineation of the PET-derived biological tumour volume (BTV) in correlation with the molecular genetic profile according the updated 2016 WHO classification. The analysis included 245 patients with newly diagnosed, histologically verified glioma and a positive 18 F-FET PET scan prior to any further treatment. BTVs were delineated during the early 5-15 min and standard 20-40 min time frames using a threshold of 1.6 × background activity and were compared intraindividually. Volume differences between early and late summation images of >20% were considered significant and were correlated with WHO grade and the molecular genetic profile (IDH mutation and 1p/19q codeletion status). In 52.2% of the patients (128/245), a significant difference in BTV of >20% between early and standard summation images was found. While 44.3% of WHO grade II gliomas (31 of 70) showed a significantly smaller BTV in the early summation images, 35.0% of WHO grade III gliomas (28/80) and 37.9% of WHO grade IV gliomas (36/95) had a significantly larger BTVs. Among IDH-wildtype gliomas, an even higher portion (44.4%, 67/151) showed significantly larger BTVs in the early summation images, which was observed in 5.3% (5/94) of IDH-mutant gliomas only: most of the latter had significantly smaller BTVs in the early summation images, i.e. 51.2% of IDH-mutant gliomas without 1p/19q codeletion (21/41) and 39.6% with 1p/19q codeletion (21/53). BTVs delineated in early and standard summation images differed significantly in

  4. Pet Health

    Science.gov (United States)

    Pets can add fun, companionship and a feeling of safety to your life. Before getting a pet, think carefully about which animal is best for ... is each family member looking for in a pet? Who will take care of it? Does anyone ...

  5. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  6. Pet Allergy

    Science.gov (United States)

    ... an allergic reaction to proteins found in an animal's skin cells, saliva or urine. Signs of pet allergy ... Allergens from cats and dogs are found in skin cells the animals shed (dander), as well as in their saliva, ...

  7. PET scan

    Science.gov (United States)

    ... The PET detects signals from the tracer. A computer changes the signals into 3D pictures. The images ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  8. Pet Allergy Quiz

    Science.gov (United States)

    ... Treatments ▸ Allergies ▸ Pet Allergy ▸ Pet Allergy Quiz Share | Pet Allergy Quiz More than half of U.S. households ... cat family. Yet, millions of people suffer from pet allergies. Take this quiz to test your knowledge ...

  9. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  10. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  11. PET for gliomas

    International Nuclear Information System (INIS)

    Shinoura, Nobusada; Momose, Toshimitsu

    1999-01-01

    CT and MRI imaging, which essentially provide the physical status of tissue, give important information on the histopathology and extent of gliomas. On the contrary, PET is a biochemical and physiologic technology and is beginning to give more precise information about gliomas, which allows the distinction between gliomas and normal brains, the supply of histopathologic and prognostic information, and the assessment of the response to the therapy. To date, fluorine-18fluorodeoxy-glucose (FDG) and 11C-methionine (MET) are widely used PET tracers for gliomas. Recent studies have demonstrated that the degree of the increase in the glycolytic rate in gliomas, as measured with FDG, is correlated with the histologic grade and prognosis. However, MET is superior to FDG in delineation of the boundaries of gliomas, because MET sometimes shows the lesion invaded by gliomas, which is usually wider than that detected by CT or MRI imaging. Finally, we discussed about 11C-Choline PET, in which T/N ratio of gliomas was remarkably high, and residual tumors were easily distinguished from surrounding normal tissues after surgery. In conclusion, it is important to know the advantage of individual PET tracers and combine a couple of tracers to obtain accurate information about gliomas. (author)

  12. {sup 18}F-FDG PET/CT following chemoradiation of uterine cervix cancer provides powerful prognostic stratification independent of HPV status: a prospective cohort of 105 women with mature survival data

    Energy Technology Data Exchange (ETDEWEB)

    Siva, Shankar; Hicks, Rodney J.; Callahan, Jason [Peter MacCallum Cancer Centre, Division of Radiation Oncology and Cancer Imaging, East Melbourne, Victoria (Australia); University of Melbourne, Sir Peter MacCallum Department of Oncology, Parkville (Australia); Deb, Siddhartha [Peter MacCallum Cancer Centre, Department of Pathology, East Melbourne (Australia); Young, Richard J. [Peter MacCallum Cancer Centre, Molecular Therapeutics and Biomarkers Laboratory, East Melbourne (Australia); Bressel, Mathias [Peter MacCallum Cancer Centre, Department of Biostatistics and Clinical Trials, East Melbourne (Australia); Mileshkin, Linda [Peter MacCallum Cancer Centre, Department of Cancer Medicine, East Melbourne (Australia); Rischin, Danny [University of Melbourne, Sir Peter MacCallum Department of Oncology, Parkville (Australia); Peter MacCallum Cancer Centre, Department of Cancer Medicine, East Melbourne (Australia); Bernshaw, David; Narayan, Kailash [Peter MacCallum Cancer Centre, Division of Radiation Oncology and Cancer Imaging, East Melbourne, Victoria (Australia)

    2015-11-15

    To report 5-year outcomes of a prospective registry study investigating posttherapy FDG PET/CT in women with locally advanced cervical cancer. A secondary analysis assessing the prognostic significance of HPV infection was performed. Patients underwent definitive chemoradiation followed by a single FDG PET/CT scan for response assessment. A complete metabolic response (CMR) was defined as no evidence of FDG-avid disease. Patients were dichotomized according to HPV infection status into a 'higher-risk' group and a 'lower-risk' group, with the higher-risk group comprising those with alpha-7 strain HPV (subtypes 18, 39 and 45) and those who were HPV-negative and the lower-risk group comprising those with alpha-9 strain HPV (subtypes 16, 31, 33, 52 and 58) and those with mixed strains. Survival outcomes, patterns of failure and salvage therapy outcomes were investigated for their association with metabolic response and HPV status. In 105 patients the median prospective follow-up was 5.2 years. The 5-year cancer-specific, overall and progression-free survival rates in patients with a CMR were 97 %, 93 % and 86 %, respectively. In patients without a CMR, the corresponding 5-year survival rates were 36 %, 22 % and 0 % respectively (p < 0.01). PET response was associated with patterns of failure (p < 0.01), with the 5-year freedom from local, nodal and distant failure in patients with a CMR being 94 %, 90 % and 94 %, respectively. Of 16 patients who underwent salvage therapy, 12 had disease detected on the surveillance PET scan, and 8 achieved a post-salvage CMR of whom all were alive at a median of 4.9 years. DNA adequate for HPV analysis was extracted in 68 patients. The likelihood of a PET metabolic response was not influenced by HPV infection status, with 71 % and 75 % of higher-risk and lower-risk patients, respectively, achieving CMR (p = 0.83). Higher-risk patients had a poorer OS (HR 2.6, range 1.0 - 6.6, p = 0.05) in univariable analysis but

  13. Pre-transplantation minimal residual disease with cytogenetic and molecular diagnostic features improves risk stratification in acute myeloid leukemia.

    Science.gov (United States)

    Oran, Betül; Jorgensen, Jeff L; Marin, David; Wang, Sa; Ahmed, Sairah; Alousi, Amin M; Andersson, Borje S; Bashir, Qaiser; Bassett, Roland; Lyons, Genevieve; Chen, Julianne; Rezvani, Katy; Popat, Uday; Kebriaei, Partow; Patel, Keyur; Rondon, Gabriela; Shpall, Elizabeth J; Champlin, Richard E

    2017-01-01

    Our aim was to improve outcome prediction after allogeneic hematopoietic stem cell transplantation in acute myeloid leukemia by combining cytogenetic and molecular data at diagnosis with minimal residual disease assessment by multicolor flow-cytometry at transplantation. Patients with acute myeloid leukemia in first complete remission in whom minimal residual disease was assessed at transplantation were included and categorized according to the European LeukemiaNet classification. The primary outcome was 1-year relapse incidence after transplantation. Of 152 patients eligible, 48 had minimal residual disease at the time of their transplant. Minimal residual disease-positive patients were older, required more therapy to achieve first remission, were more likely to have incomplete recovery of blood counts and had more adverse risk features by cytogenetics. Relapse incidence at 1 year was higher in patients with minimal residual disease (32.6% versus 14.4%, P=0.002). Leukemia-free survival (43.6% versus 64%, P=0.007) and overall survival (48.8% versus 66.9%, P=0.008) rates were also inferior in patients with minimal residual disease. In multivariable analysis, minimal residual disease status at transplantation independently predicted 1-year relapse incidence, identifying a subgroup of intermediate-risk patients, according to the European LeukemiaNet classification, with a particularly poor outcome. Assessment of minimal residual disease at transplantation in combination with cytogenetic and molecular findings provides powerful independent prognostic information in acute myeloid leukemia, lending support to the incorporation of minimal residual disease detection to refine risk stratification and develop a more individualized approach during hematopoietic stem cell transplantation. Copyright© Ferrata Storti Foundation.

  14. 18F-FDG PET and PET/CT in Burkitt's lymphoma

    International Nuclear Information System (INIS)

    Karantanis, Dimitrios; Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P.; Georgiou, Evangelos; Johnston, Patrick B.; Wiseman, Gregory A.

    2010-01-01

    Objective: To explore the value of 18 F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  15. PET studies in dementia

    Energy Technology Data Exchange (ETDEWEB)

    Herholz, K. [Neurologische Universitaetsklinik and Max-Planck-Inst. fuer neurologische Forschung, Koeln (Germany)

    2003-04-01

    Measurement of local cerebral glucose metabolism (lCMRGlc) by positron emission tomography (PET) and {sup 18}F-2-fluoro-2-deoxy-D-glucose (FDG) has become a standard technique during the past 20 years and is now available at many university hospitals in all highly developed countries. Many studies have documented a close relation between lCMRGlc and localized cognitive functions, such as language and visuoconstructive abilities. Alzheimer's disease (AD) is characterized by regional impairment of cerebral glucose metabolism in neocortical association areas (posterior cingulate, temporoparietal and frontal multimodal association cortex), whereas primary visual and sensorimotor cortex, basal ganglia, and cerebellum are relatively well preserved. In a multicenter study comprising 10 PET centers (Network for Efficiency and Standardization of Dementia Diagnosis, NEST-DD) that employed an automated voxel-based analysis of FDG PET images, the distinction between controls and AD patients was 93% sensitive and 93% specific, and even in very mild dementia (at Mini Mental Status Examination (MMSE) 24 or higher) sensitivity was still 84% at 93% specificity. Significantly abnormal metabolism in mild cognitive deficit (MCI) indicates a high risk to develop dementia within the next two years. Reduced neocortical glucose metabolism can probably be detected with FDG PET in AD on average one year before onset of subjective cognitive impairment. In addition to glucose metabolism, specific tracers for dopamine synthesis ({sup 18}F-F-DOPA) and for ({sup 11}C-MP4A) are of interest for differentiation among dementia subtypes. Cortical acetylcholine esterase activity (AChE) activity is significantly lower in patients with AD or with dementia with Lewy bodies (DLB) than in age-matched normal controls. In LBD there is also impairment of dopamine synthesis, similar to Parkinson disease. (author) 115 refs.

  16. Pet ownership and adolescent health: cross-sectional population study.

    Science.gov (United States)

    Mathers, Megan; Canterford, Louise; Olds, Tim; Waters, Elizabeth; Wake, Melissa

    2010-12-01

    To determine whether adolescent health and well-being are associated with having a pet in the household (any pet, or specifically dogs, cats or horses/ponies) or average daily time spent caring for/playing with pet(s). Design, setting and participants--Cross-sectional data from the third wave of the Health of Young Victorians Study (HOYVS), a school-based population study in Victoria, Australia. Predictors--Adolescent-reported pet ownership and average daily time spent caring for/playing with pet(s). Outcomes--Self-reported quality of life (KIDSCREEN); average 4-day daily physical activity level from a computerised diary; parent-proxy and self-reported physical and psychosocial health status (PedsQL); measured BMI status (not overweight, overweight, obese) and blood pressure. Statistical Analysis--Regression methods, adjusted for socio-demographic factors, and non-parametric methods. Household pet data were available for 928 adolescents (466 boys; mean age of 15.9 (SD 1.2) years). Most adolescents (88.7%) reported having a pet in their household. Of these, 75.1% reported no activity involving pets over the surveyed days. It appeared that neither owning a pet nor time spent caring for/playing with a pet was related, positively or negatively, to adolescent health or well-being. Despite high rates of pet ownership, adolescents had little interaction with pets. It appears that owning a pet and time spent caring for/playing with a pet was not clearly associated with adolescents' health or well-being. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  17. Pet Problems at Home: Pet Problems in the Community.

    Science.gov (United States)

    Soltow, Willow

    1984-01-01

    Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…

  18. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  19. (R-[11C]Verapamil PET studies to assess changes in P-glycoprotein expression and functionality in rat blood-brain barrier after exposure to kainate-induced status epilepticus

    Directory of Open Access Journals (Sweden)

    Lammertsma Adriaan A

    2011-01-01

    Full Text Available Abstract Background Increased functionality of efflux transporters at the blood-brain barrier may contribute to decreased drug concentrations at the target site in CNS diseases like epilepsy. In the rat, pharmacoresistant epilepsy can be mimicked by inducing status epilepticus by intraperitoneal injection of kainate, which leads to development of spontaneous seizures after 3 weeks to 3 months. The aim of this study was to investigate potential changes in P-glycoprotein (P-gp expression and functionality at an early stage after induction of status epilepticus by kainate. Methods (R-[11C]verapamil, which is currently the most frequently used positron emission tomography (PET ligand for determining P-gp functionality at the blood-brain barrier, was used in kainate and saline (control treated rats, at 7 days after treatment. To investigate the effect of P-gp on (R-[11C]verapamil brain distribution, both groups were studied without or with co-administration of the P-gp inhibitor tariquidar. P-gp expression was determined using immunohistochemistry in post mortem brains. (R-[11C]verapamil kinetics were analyzed with approaches common in PET research (Logan analysis, and compartmental modelling of individual profiles as well as by population mixed effects modelling (NONMEM. Results All data analysis approaches indicated only modest differences in brain distribution of (R-[11C]verapamil between saline and kainate treated rats, while tariquidar treatment in both groups resulted in a more than 10-fold increase. NONMEM provided most precise parameter estimates. P-gp expression was found to be similar for kainate and saline treated rats. Conclusions P-gp expression and functionality does not seem to change at early stage after induction of anticipated pharmacoresistant epilepsy by kainate.

  20. 24 CFR 5.318 - Discretionary pet rules.

    Science.gov (United States)

    2010-04-01

    ... PHAs may include, but are not limited to, consideration of the following factors: (a) Definitions of... “common household pet” in their pet rules must use the Housing programs definition of the term in § 5.306... status of tenants of projects for the elderly or persons with disabilities. (iii) For pet deposits...

  1. [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars; Burg, Matthias Christian; Allkemper, Thomas; Schaefers, Michael

    2016-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [ 18 F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [ 18 F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [ 18 F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [ 18 F]FDG PET/MRI was inferior to low-dose [ 18 F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [ 18 F]FDG PET/MRI was equal to contrast-enhanced neck [ 18 F]FDG PET/CT. Therefore, [ 18 F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast agent is contraindicated. (orig.)

  2. Leptospirosis and Pets

    Science.gov (United States)

    ... Bacterial Special Pathogens Branch (BSPB) BSPB Laboratory Submissions Pets Recommend on Facebook Tweet Share Compartir Leptospirosis is ... that can affect human and animals, including your pets. All animals can potentially become infected with Leptospirosis. ...

  3. Birds Kept as Pets

    Science.gov (United States)

    ... of pet birds. Because of the risk of avian influenza (bird flu), USDA restricts the importation of pet birds from ... or look dirty may be ill. Learn the signs of illness in a bird, which include appearing ...

  4. [Principles of PET].

    Science.gov (United States)

    Beuthien-Baumann, B

    2018-04-19

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  5. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  6. PET in management of breast cancer

    International Nuclear Information System (INIS)

    Lee, Myung-Chul

    2004-01-01

    Full text: PET provides useful information about tumor metabolism enabling accurate visualization of malignant lesions. Approximately 60-80% suspicious lesions on mammography have benign histology and about 10% of breast cancers with palpable mass are not identified in mammography. The key roles of PET technology in breast cancer are in: primary diagnosis, staging, recurrent diseases monitoring and prediction of therapy response. The sensitivity and specificity of FDG-PET for the diagnosis of breast cancer has been reported to be 68-100% and 83-100%, respectively. Considering the increasing number of small breast tumors detected by mammography and false negative results, the clinical relevance of FDG-PET for the primary diagnosis is limited. In selected patients, however, for example with dense breasts, breasts implants, augmented breast or after breast surgery, which can affect the accuracy of mammography, and in cases with equivocal mammography, FDG-PET can provide clinically relevant information. PET accurately determines the extent of disease, including the loco-regional lymph node status. Furthermore, whole-body PET imaging promises a high diagnostic accuracy for detecting recurrent or metastatic breast carcinoma with a high positive predictive value. We studied the usefulness of the FDG-PET in 42 preoperative patients with suspected breast cancer in differentiation of lesions. The diagnostic value of FDG-PET in terms of sensitivity and specificity was 95% and 77% respectively in primary mass while it was 73% and 100% for axillary lymph nodes. PET is much more accurate than other conventional modalities. The sensitivity of FDG-PET for correct staging of axillary nodal status is 84-100%. It has the potential to replace conventional procedures for the staging of distant metastases. We observed the sensitivity and the specificity of FDG-PET to be 96% and 85% to detect distant metastases. FDG-PET may become the method of choice for the early assessment of

  7. NIRS report of investigations for the development of the next generation PET apparatus. FY 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    The present status of studies conducted by representative technology fields for the development of the next generation PET apparatus, and the summary of opinions given by investigators of nuclear medicine are reported. The former involves chapters of: Summary of representative technologies for the development of the next generation PET apparatus; Count rate analysis of PET apparatuses for the whole body and small animals by PET simulator; Scintillator; DOI (depth of interaction) detector-evaluation of the detector with 256-ch fluorescence polarization-photomultiplier tubes (FP-PMT) trial apparatus etc; Examination of multi-slice DOI-MR compatible detector for PET; Development of application specific integrated circuit (ASIC) for processing the front-end signals; Detector simulation; Circuit for processing PET detector signals; Signal processing-coincidence circuit; Data collection system; Signal processing technology for the next generation PET; Reconstruction of statistical PET image using DOI signals; Monte Carlo simulation and Unique directions-PET for infants and for the whole body autonomic nervous systems and mental activity; and Actual design and evaluation of image reconstruction by statistical means. Opinions are: Progress of clinical PET apparatus; Desirable PET drugs and apparatuses; From clinical practice for the development of the next generation PET apparatus; >From clinical psychiatric studies for the development; From application of drug development and basic researches; From brain PET practice; From clinical PET practice; and The role of National Institute of Radiological Sciences (NIRS) in PET development. Also involved is the publication list. (N.I.)

  8. PET and Hormone Receptor Ligands in Breast Cancer

    National Research Council Canada - National Science Library

    Gemignani, Mary

    2006-01-01

    .... To investigate this further, this project's objectives are: To evaluate the use of estrogen-like ligands labeled with positron emitters in preoperatively determining the ER status of breast cancer using PET...

  9. PET in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, Stefan (ed.) [HELIOS Klinikum Berlin-Buch, Berlin (Germany). Klinik fuer Nuklearmedizin

    2008-07-01

    In the management of oncologic diseases, modern imaging modalities contribute heavily to the decision of which form of treatment - local or systemic, surgical or interdisciplinary - will be most efficient. The addition of functional image information to conventional staging procedures helps improve the diagnostic pathway. The information needed for therapeutic management and for follow-up can be provided by correlative imaging such as positron emission tomography (PET) and computed tomography (CT) or PET/CT. This book is a comprehensive compilation of the accumulated knowledge on PET and PET/CT in oncology, covering the entire spectrum from solidly documented indications, such as staging and monitoring of lung and colorectal cancer, to the application of PET/CT in head and neck surgery, gynecology, radiation therapy, urology, pediatrics etc. It is aimed at nuclear medicine and radiology specialists as well as physicians interested in the possibilities and limitations of PET and PET/CT in oncology. (orig.)

  10. PET in Benign Bone Marrow Disorders

    NARCIS (Netherlands)

    van der Bruggen, Wouter; Glaudemans, Andor W. J. M.; Vellenga, Edo; Slart, Riemer H. J. A.

    This review aims to describe the current status of benign bone marrow (BM) imaging using PET. BM imaging is important as the BM is not only involved in poiesis of different vital cell lines and. can be affected by primary BM disorders, but it is also frequently affected by several extramedullary

  11. Sensory analysis of pet foods.

    Science.gov (United States)

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  12. Pet ownership, dog types and attachment to pets in 9–10 year old children in Liverpool, UK

    Science.gov (United States)

    2013-01-01

    Background Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or ‘attachment’ that children have to their pet. Data were collected using a survey of 1021 9–10 year old primary school children in a deprived area of the city of Liverpool, UK. Results Dogs were the most common pet owned, most common ‘favourite’ pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a ‘Bull Breed’ dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child’s favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and ‘other’ pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. ‘Pit Bull or cross’ and ‘Bull Breed’ dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a ‘Pit Bull or cross’ than Whites. Conclusions Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when

  13. Pet ownership, dog types and attachment to pets in 9-10 year old children in Liverpool, UK.

    Science.gov (United States)

    Westgarth, Carri; Boddy, Lynne M; Stratton, Gareth; German, Alexander J; Gaskell, Rosalind M; Coyne, Karen P; Bundred, Peter; McCune, Sandra; Dawson, Susan

    2013-05-13

    Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or 'attachment' that children have to their pet. Data were collected using a survey of 1021 9-10 year old primary school children in a deprived area of the city of Liverpool, UK. Dogs were the most common pet owned, most common 'favourite' pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a 'Bull Breed' dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child's favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and 'other' pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. 'Pit Bull or cross' and 'Bull Breed' dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a 'Pit Bull or cross' than Whites. Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when conducting research into the health benefits and risks of the

  14. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  15. Beneficial effects of pet ownership on some aspects of human health and behaviour.

    OpenAIRE

    Serpell, J

    1991-01-01

    A 10-month prospective study was carried out which examined changes in behaviour and health status in 71 adult subjects following the acquisition of a new pet (either dogs or cats). A group of 26 subjects without pets served as a comparison over the same period. Both pet-owning groups reported a highly significant reduction in minor health problems during the first month following pet acquisition, and this effect was sustained in dog owners through to 10 months. The pet-acquiring groups also ...

  16. Household Hazards to Pets

    Science.gov (United States)

    ... visitors can pose a special challenge to your pets. Discourage well- meaning guests from spoiling pets with extra treats and scraps from the dinner ... other soft bones can splinter and damage your pet’s mouth or esophagus. While trick or treating is ...

  17. Pets and Parasites

    Science.gov (United States)

    ... animals. This is how cats get the toxoplasmosis parasite. Keep your pets away from wild animals or stray pets (which may be unvaccinated or sick). Things to consider Reptiles (such as lizards, snakes, and turtles) carry bacteria (germs) that can make ...

  18. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  19. Usage of Recycled Pet

    Directory of Open Access Journals (Sweden)

    A. Ebru Tayyar

    2010-01-01

    Full Text Available The increasing industrialization, urbanization and the technological development have caused to increase depletion of the natural resources and environmental pollution's problem. Especially, for the countries which have not enough space recycling of the waste eliminating waste on regular basis or decreasing the amount and volume of waste have provided the important advantages. There are lots of studies and projects to develop both protect resources and prevent environmental pollution. PET bottles are commonly used in beverage industry and can be reused after physical and chemical recycling processes. Usage areas of recycled PET have been developed rapidly. Although recycled PET is used in plastic industry, composite industry also provides usage alternatives of recycled PET. Textile is a suitable sector for recycling of some plastics made of polymers too. In this study, the recycling technologies and applications of waste PET bottles have been investigated and scientific works in this area have been summarized.

  20. Methodology for quantitative rapid multi-tracer PET tumor characterizations.

    Science.gov (United States)

    Kadrmas, Dan J; Hoffman, John M

    2013-10-04

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted.

  1. TH-A-17A-01: Innovation in PET Instrumentation and Applications

    International Nuclear Information System (INIS)

    Casey, M; Miyaoka, R; Shao, Y

    2014-01-01

    Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality and quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications

  2. [{sup 18}F]FDG PET/CT outperforms [{sup 18}F]FDG PET/MRI in differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Burg, Matthias Christian; Allkemper, Thomas [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Schaefers, Michael [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Westfaelische Wilhelms University Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2016-02-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [{sup 18}F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [{sup 18}F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [{sup 18}F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [{sup 18}F]FDG PET/MRI was inferior to low-dose [{sup 18}F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [{sup 18}F]FDG PET/MRI was equal to contrast-enhanced neck [{sup 18}F]FDG PET/CT. Therefore, [{sup 18}F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast

  3. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    Directory of Open Access Journals (Sweden)

    Mustafa Demir

    2018-02-01

    Full Text Available Objective: The aim of the present study was to compare the performance of positron emission tomography (PET component of PET/computed tomography (CT with new emerging PET/magnetic resonance (MR of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. Results: The findings of this study demonstrated superior sensitivity (~ 4 folds of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9% compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. Conclusion: It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  4. 11C-methionine PET as a prognostic marker in patients with glioma: comparison with18F-FDG PET

    International Nuclear Information System (INIS)

    Kim, Sungeun; Chung, June-Key; Jeong, Jae Min; Im, So-Hyang; Kim, Dong Gyu; Jung, Hee Won; Lee, Dong Soo; Lee, Myung Chul

    2005-01-01

    The purpose of this study was to compare the prognostic value of 11 C-methionine (MET) and 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in glioma patients. The study population comprised 47 patients with gliomas (19 glioblastoma, 28 others). Pretreatment magnetic resonance imaging, MET PET and FDG PET were performed within a time interval of 2 weeks in all patients. The uptake ratio and standard uptake values were calculated. Univariate and multivariate analyses were done to determine significant prognostic factors. Ki-67 index was measured by immunohistochemical staining, and compared with FDG and MET uptake in glioma. Among the several clinicopathological prognostic factors, tumour pathology (glioblastoma or not), age (≥60 or <60 years), Karnofsky performance status (KPS) (≥70 or <70) and MET PET (higher uptake or not compared with normal cortex) were found to be significant predictors by univariate analysis. In multivariate analysis, tumour pathology, KPS and MET PET were identified as significant independent predictors. The Ki-67 proliferation index was significantly correlated with MET uptake (r=0.64), but not with FDG uptake. Compared with FDG PET in glioma, MET PET was an independent significant prognostic factor and MET uptake was correlated with cellular proliferation. MET PET may be a useful biological prognostic marker in glioma patients. (orig.)

  5. Does owning a pet protect older people against loneliness?

    Science.gov (United States)

    Pikhartova, Jitka; Bowling, Ann; Victor, Christina

    2014-09-20

    Pet ownership is thought to make a positive contribution to health, health behaviours and the general well-being of older people. More specifically pet ownership is often proposed as a solution to the problem of loneliness in later life and specific 'pet based' interventions have been developed to combat loneliness. However the evidence to support this relationship is slim and it is assumed that pet ownership is a protection against loneliness rather than a response to loneliness. The aim of this paper is to examine the association between pet ownership and loneliness by exploring if pet ownership is a response to, or protection against, loneliness using Waves 0-5 from the English Longitudinal Study of Ageing (ELSA). Using data from 5,210 men and women in the English Longitudinal Study of Ageing, cross-sectional and longitudinal regression analysis was used to assess the bi-directional relationship between loneliness and pet ownership among adults aged 50 + . In 2001 (wave 0) 41% of participants were pet owners compared with 30% in 2010 (Wave 5). The association between pet ownership and loneliness is stronger in women than men, and in both directions (i.e. pet ownership predicting loneliness and loneliness predicting pet ownership) and of the similar magnitude (OR 1.2-1.4). Age, social relationships, demographic factors and health behaviour variables have only a minimal influence upon the association between loneliness and pet ownership. The results of our longitudinal analysis showed that women who reported being lonely always in Waves 0 to 5 were more likely to have a pet in Wave 5. Reported loneliness is dependent on socio-demographic characteristics such as gender, household income, household living arrangements and health status. Taking those factors into account, owning a pet significantly influences later reporting of loneliness in women in our longitudinal analysis. In the reverse direction, reported loneliness influences pet ownership in later waves

  6. Impact of Pretransplantation Indices in Hematopoietic Stem Cell Transplantation: Knowledge of Center-Specific Outcome Data Is Pivotal before Making Index-Based Decisions.

    Science.gov (United States)

    Törlén, Johan; Remberger, Mats; Le Blanc, Katarina; Ljungman, Per; Mattsson, Jonas

    2017-04-01

    Outcome after allogeneic hematopoietic stem cell transplantation is influenced by patient comorbidity, disease type, and status before treatment. We performed a retrospective study involving 521 consecutive adult hematopoietic stem cell transplantation patients who underwent transplantation for hematological malignancy at our center from 2000 to 2012 to compare the predictive value of the hematopoietic cell transplantation-specific comorbidity index (HCT-CI) and the disease risk index (DRI) for overall survival and transplantation-related mortality. Patients in the highest HCT-CI risk group (HCT-CI score ≥3) had a lower 5-year overall survival rate (50%) than the low-risk group (63%; P 6 [n = 9]). Five-year overall survival in the highest DRI risk group was significantly poorer (44%) than in the low-risk group (63%; P indices failed to predict differences in transplantation-related mortality (HCT-CI, P = .54; DRI, P = .17). We conclude that HCT-CI and DRI were predictive of overall survival in our patient population. Even so, our data show that different patient groups may have different outcomes despite sharing the same index risk group and that indices should, therefore, be evaluated according to local data before clinical implementation at the single-center level. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  7. Healthy Pets and People

    Science.gov (United States)

    ... people to get sick from diseases shared between animals and people (also known as zoonotic diseases or zoonoses). CDC ... valuable source of information on diseases shared between animals and people. Keep Your Pet Healthy Whether you have a ...

  8. PET and Recycling

    OpenAIRE

    Funda Sevencan; Songul A. Vaizoglu

    2007-01-01

    This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET) is the most commonly used plastics. PET is used to protect food, drinking water,...

  9. Neutering of cats and dogs in Ireland; pet owner self-reported perceptions of enabling and disabling factors in the decision to neuter.

    Science.gov (United States)

    Downes, Martin J; Devitt, Catherine; Downes, Marie T; More, Simon J

    2015-01-01

    Background. Failure among pet owners to neuter their pets results in increased straying and overpopulation problems. Variations in neutering levels can be explained by cultural differences, differences in economic status in rural and urban locations, and owner perceptions about their pet. There are also differences between male and female pet owners. There is no research pertaining to Irish pet owner attitudes towards neutering their pets. This paper identified the perceptions of a sample of Irish cat and dog owners that influenced their decisions on pet neutering. Methods. This study was conducted using social science (qualitative) methods, including an interview-administered survey questionnaire and focus group discussions. Data was coded and managed using Nvivo 8 qualitative data analysis software. Results. Focus groups were conducted with 43 pet (cats and dogs) owners. Two major categories relating to the decision to neuter were identified: (1) enabling perceptions in the decision to neuter (subcategories were: controlling unwanted pet behaviour; positive perceptions regarding pet health and welfare outcomes; perceived owner responsibility; pet function; and the influence of veterinary advice), and (2) disabling perceptions in the decision to neuter (subcategories were: perceived financial cost of neutering; perceived adequacy of existing controls; and negative perceptions regarding pet health and welfare outcomes). Discussion. Pet owner sense of responsibility and control are two central issues to the decision to neuter their pets. Understanding how pet owners feel about topics such as pet neutering, can help improve initiatives aimed at emphasising the responsibility of population control of cats and dogs.

  10. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  11. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ( 18 F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  12. PET applications in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Shulkin, B. L. [Ann Arbor, Univ. of Michigan Medical Center (United States). Pediatric Nuclear Medicine Section

    1997-12-01

    This article summarizes the major PET studies which have been performed in pediatric patients to elucidate and characterize diseases and normal development. Issues special for the application of the technique in children, such as dosimetry, patient preparation, and image acquisition are discussed. Studies of central nervous system (CNS) development and pathology, including epilepsy, intraventricular hemorrhage, neonatal asphyxia, tumors, and effects on the CNS from treatment of other tumors are reviewed. These have contributed information fundamental to their understanding of CNS development and pathology. PET investigations into the pathophysiology of congenital heart disease have begun and hold great promise to aid their understanding of these conditions. The second major area in which PET has been applied is the study of non CNS neoplasms. Neuroblastoma has been investigated with tracers which explore basic biochemical features which characterize this tumor, as well as with tracers which explore biochemical events relatively specific for this malignancy. Other common and uncommon tumors of childhood are discussed. The PET technique has been shown useful for answering questions of clinical relevance for the management of these uncommon neoplasms. PET is likely to continue to aid their understanding of many pediatric diseases and may gain more widespread clinical acceptance as the technology continues to disseminate rapidly.

  13. Medical application of PET technology

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Choi, C. W.; An, S. H.; Woo, K. S.; Chung, W. S.; Yang, S. D.; Jun, G. S. and others

    1999-04-01

    We performed following studies using PET technology: 1. Clinical usefulness of [ 18 F]FDG whole body PET in malignant disease 2. Clinical usefulness of quantitative evaluation of F-18-FDG 3. Pilot study of C-11 methionine PET in brain tumor 4. PET study in patients with Parkinson's disease 5. A study on the clinical myocardial PET image. PET gives various metabolic information for the living human body, and is very important, new diagnostic modality. The PET study will give us the information of cancer patients such as early detection of cancer, staging, recurrence detection and characterization of cancer. The quantitative analysis using PET could be applied to evaluate the pathophysiology of various diseases and develop new drugs and develop new radiopharmaceuticals

  14. PET in neuro-oncology

    NARCIS (Netherlands)

    Roelcke, U; Leenders, K.L.

    This article reviews possible clinical applications of positron emission tomography (PET) in brain tumor patients. PET allows quantitative assessment of brain tumor pathophysiology and biochemistry. It therefore provides different information about tumors when compared to histological or

  15. Take Care with Pet Reptiles

    Science.gov (United States)

    ... Submit Button Past Emails Take Care with Pet Reptiles and Amphibians Language: English (US) Español (Spanish) Recommend ... pets and disease risks Safe Handling Tips for Reptiles and Amphibians Always wash your hands thoroughly after ...

  16. Medical application of PET technology

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Choi, C. W.; An, S. H.; Woo, K. S.; Chung, W. S.; Yang, S. D.; Jun, G. S. and others

    1999-04-01

    We performed following studies using PET technology: 1. Clinical usefulness of [{sup 18}F]FDG whole body PET in malignant disease 2. Clinical usefulness of quantitative evaluation of F-18-FDG 3. Pilot study of C-11 methionine PET in brain tumor 4. PET study in patients with Parkinson's disease 5. A study on the clinical myocardial PET image. PET gives various metabolic information for the living human body, and is very important, new diagnostic modality. The PET study will give us the information of cancer patients such as early detection of cancer, staging, recurrence detection and characterization of cancer. The quantitative analysis using PET could be applied to evaluate the pathophysiology of various diseases and develop new drugs and develop new radiopharmaceuticals.

  17. Pre-transplantation risk factors to develop sclerotic chronic GvHD after allogeneic HSCT: a multicenter retrospective study from the Société Française de Greffe de Moelle et de Thérapie Cellulaire (SFGM-TC).

    Science.gov (United States)

    Detrait, M Y; Morisset, S; Peffault de Latour, R; Yakoub-Agha, I; Crocchiolo, R; Tabrizi, R; Bay, J-O; Chevalier, P; Barraco, F; Raus, N; Vigouroux, S; Magro, L; Mohty, M; Milpied, N; Blaise, D; Socié, G; Michallet, M

    2015-02-01

    Sclerotic chronic GvHD (cGvHD) is one of the most severe complications after allo-hematopoietic stem cell transplantation (HSCT). Risk factors associated with this complication remain not very well defined. With the aim to define a pre-transplantation risk profile, we have conducted a French retrospective analysis in 705 consecutive patients between 2005 and 2010. Analyses to determine pre-transplantation risk factors included as variables: patient and donor age, kind of donor, HLA matching, ABO matching, sex-matching, diagnosis, stem cell source, gender, GvHD prophylaxis and antithymocyte globulin (ATG) in the conditioning regimen. The cumulative incidence of sclerotic cGvHD was 18% (95% CI, 16.6-19.6) 3 years after onset of cGvHD. In univariate analysis, we found a significantly lower number of sclerotic cGvHD form in patients transplanted from cord blood cells (P=0.0021), in patients with a one mismatched donor (P=0.041) and in patients who had received ATG in the conditioning regimen (P=0.002). In multivariate analysis, factors associated with an increased risk of sclerotic cGvHD were young patient age, multiple myeloma and PBSC as the stem cell source. ATG in conditioning regimen and cord blood unit as the stem cell source were associated with a lower risk.

  18. PET imaging of inflammation

    International Nuclear Information System (INIS)

    Buscombe, J. R.

    2014-01-01

    Inflammatory diseases are common place and often chronic. Most inflammatory cells have increased uptake of glucose which is enhanced in the presence of local cytokines. Therefore, imaging glucose metabolism by the means of 18F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) holds significant promise in imaging focal inflammation. Most of the work published involved small series of patients with either vasculitis, sarcoid or rheumatoid arthritis. It would appear that FDG PET is a simple and effective technique to identify inflammatory tissue in these conditions. There is even some work to suggest that by comparing baseline and early post therapy scans clinical outcome can be predicted. This would appear to be true with vasculitis as well as retroperitoneal fibrosis. The number of patients in each study is small but the evidence is compelling enough to recommend FDG PET imaging in the routine care of these patients.

  19. PET imaging in multiple sclerosis

    NARCIS (Netherlands)

    Faria, Daniele de Paula; Copray, Sjef; Buchpiguel, Carlos; Dierckx, Rudi; de Vries, Erik

    Positron emission tomography (PET) is a non-invasive technique for quantitative imaging of biochemical and physiological processes in animals and humans. PET uses probes labeled with a radioactive isotope, called PET tracers, which can bind to or be converted by a specific biological target and thus

  20. PET in infancy predicts long-term outcome during adolescence in cryptogenic West syndrome.

    Science.gov (United States)

    Natsume, J; Maeda, N; Itomi, K; Kidokoro, H; Ishihara, N; Takada, H; Okumura, A; Kubota, T; Miura, K; Aso, K; Morikawa, T; Kato, K; Negoro, T; Watanabe, K

    2014-08-01

    Developmental and seizure outcomes in patients with cryptogenic West syndrome are variable. Our aim was to clarify the relationship between FDG-PET findings in infancy and long-term seizure and developmental outcome in cryptogenic West syndrome. From 1991 to 1999, we prospectively performed FDG-PET from the onset of cryptogenic West syndrome in 27 patients. PET was performed at onset and at 10 months of age. In 2012, we evaluated the educational status, psychomotor development, and seizure outcome in 23 of the 27 patients (13-22 years of age). The correlation between PET findings and outcome was evaluated. At onset, PET showed hypometabolism in 13 patients (57%). The second PET after the initial treatment revealed cortical hypometabolism in 7 patients (30%). While hypometabolism at onset disappeared on the second PET in 9 patients, it was newly revealed in 3 patients on the second PET. In 2012, seven patients had persistent or recurrent seizures. Eight patients had intellectual impairment. The first PET did not correlate with seizure or developmental outcome. Five of 7 patients (71%) with hypometabolism seen on the second PET had persistent or recurrent seizures, while 14 of 16 (88%) patients with normal findings on the second PET were free of seizures. Five of 7 patients (71%) showing hypometabolism on the second PET had intellectual impairment. Thirteen of 16 (81%) patients with normal findings on the second PET showed normal intelligence. A significant correlation was found between the second PET and long-term seizure (P = .01) or developmental outcome (P = .03). Cortical hypometabolism is not permanent; it changes with clinical symptoms. Hypometabolism after initial treatment predicts long-term seizures and poor developmental outcome. © 2014 by American Journal of Neuroradiology.

  1. PET and endocrine tumors

    International Nuclear Information System (INIS)

    Rigo, P.; Belhocine, T.; Hustinx, R.; Foidart-Willems, J.

    2000-01-01

    The authors review the main indications of PET examination, and specifically of 18 FDG, in the assessment of endocrine tumors: of the thyroid, of the parathyroid, of the adrenal and of the pituitary glands. Neuroendocrine tumors, gastro-entero-pancreatic or carcinoid tumors are also under the scope. Usually, the most differentiated tumors show only poor uptake of the FDG as they have a weak metabolic and proliferative activity. In the assessment of endocrine tumors, FDG-PET should be used only after most specific nuclear examinations been performed. (author)

  2. PET/MR in oncology

    DEFF Research Database (Denmark)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin

    2012-01-01

    of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number...... be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new...

  3. Diagnostic and prognostic correlates of preoperative FDG PET for breast cancer.

    Science.gov (United States)

    Vinh-Hung, Vincent; Everaert, Hendrik; Lamote, Jan; Voordeckers, Mia; van Parijs, Hilde; Vanhoeij, Marian; Verfaillie, Guy; Fontaine, Christel; Vees, Hansjoerg; Ratib, Osman; Vlastos, Georges; De Ridder, Mark

    2012-10-01

    To explore the preoperative utility of FDG PET for the diagnosis and prognosis in a retrospective breast cancer case series. In this retrospective study, 104 patients who had undergone a preoperative FDG PET scan for primary breast cancer at the UZ Brussel during the period 2002-2008 were identified. Selection criteria were: histological confirmation, FDG PET performed prior to therapy, and breast surgery integrated into the primary therapy plan. Patterns of increased metabolism were recorded according to the involved locations: breast, ipsilateral axillary region, internal mammary chain, or distant organs. The end-point for the survival analysis using Cox proportional hazards was disease-free survival. The contribution of prognostic factors was evaluated using the Akaike information criterion and the Nagelkerke index. PET positivity was associated with age, gender, tumour location, tumour size >2 cm, lymphovascular invasion, oestrogen and progesterone receptor status. Among 63 patients with a negative axillary PET status, 56 (88.9 %) had three or fewer involved nodes, whereas among 41 patients with a positive axillary PET status, 25 (61.0 %) had more than three positive nodes (P < 0.0001). In the survival analysis of preoperative characteristics, PET axillary node positivity was the foremost statistically significant factor associated with decreased disease-free survival (hazard ratio 2.81, 95% CI 1.17-6.74). Preoperative PET axillary node positivity identified patients with a higher burden of nodal involvement, which might be important for treatment decisions in breast cancer patients.

  4. Diagnostic and prognostic correlates of preoperative FDG PET for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vinh-Hung, Vincent [University of Geneva, Department of Imaging and Medical Information Sciences, University Hospitals of Geneva, Geneva (Switzerland); University of Geneva, Radiation Oncology, University Hospitals of Geneva, Geneva (Switzerland); Everaert, Hendrik [Vrije Universiteit Brussel, Department of Nuclear Medicine, UZ Brussel, Brussels (Belgium); Lamote, Jan; Vanhoeij, Marian; Verfaillie, Guy [Vrije Universiteit Brussel, Department of Surgery, UZ Brussel, Brussels (Belgium); Voordeckers, Mia; Parijs, Hilde van; Ridder, Mark de [Vrije Universiteit Brussel, Department of Radiotherapy, UZ Brussel, Brussels (Belgium); Fontaine, Christel [Vrije Universiteit Brussel, Department of Medical Oncology UZ Brussel, Brussels (Belgium); Vees, Hansjoerg; Ratib, Osman [University of Geneva, Department of Imaging and Medical Information Sciences, University Hospitals of Geneva, Geneva (Switzerland); Vlastos, Georges [University of Geneva, Department of Surgical Senology, University Hospitals of Geneva, Geneva (Switzerland)

    2012-10-15

    To explore the preoperative utility of FDG PET for the diagnosis and prognosis in a retrospective breast cancer case series. In this retrospective study, 104 patients who had undergone a preoperative FDG PET scan for primary breast cancer at the UZ Brussel during the period 2002-2008 were identified. Selection criteria were: histological confirmation, FDG PET performed prior to therapy, and breast surgery integrated into the primary therapy plan. Patterns of increased metabolism were recorded according to the involved locations: breast, ipsilateral axillary region, internal mammary chain, or distant organs. The end-point for the survival analysis using Cox proportional hazards was disease-free survival. The contribution of prognostic factors was evaluated using the Akaike information criterion and the Nagelkerke index. PET positivity was associated with age, gender, tumour location, tumour size >2 cm, lymphovascular invasion, oestrogen and progesterone receptor status. Among 63 patients with a negative axillary PET status, 56 (88.9 %) had three or fewer involved nodes, whereas among 41 patients with a positive axillary PET status, 25 (61.0 %) had more than three positive nodes (P < 0.0001). In the survival analysis of preoperative characteristics, PET axillary node positivity was the foremost statistically significant factor associated with decreased disease-free survival (hazard ratio 2.81, 95% CI 1.17-6.74). Preoperative PET axillary node positivity identified patients with a higher burden of nodal involvement, which might be important for treatment decisions in breast cancer patients. (orig.)

  5. I Love Petting Zoos!

    Centers for Disease Control (CDC) Podcasts

    2010-03-23

    This Kidtastics podcast helps children learn about how to stay safe and healthy when visiting petting zoos and other animal exhibits.  Created: 3/23/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/23/2010.

  6. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...

  7. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D L; Pichler, B J; Gückel, B

    2018-01-01

    The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants...

  8. Control of pet animals.

    Science.gov (United States)

    Collins, T F

    1976-06-26

    Pet animals play an important and valuable role in human society, but irresponsible ownership has created problems of surplus animals, threats to health, pollution, nuisance, cruelty and neglect. Urgent and drastic action is required to deal with the situation, and the measures proposed include the appointment of dog wardens, limitation of numbers, enclosure and leash laws, and subsidised spay clinics.

  9. PET and PET/CT in malignant melanoma; PET y PET/CT en melanoma maligno

    Energy Technology Data Exchange (ETDEWEB)

    Garcia O, J.R. [Nuclear Medicine and Molecular Imaging PET/CT, Centro Medico ABC, Mexico D.F. (Mexico)

    2007-07-01

    The advantages that it has the PET/CT are: 1. It diminishes mainly positive false lesions. It identifies physiologic accumulate places. 2. It diminishes in smaller grade false negative. Small injuries. Injuries with low grade concentration. Injure on intense activity areas. 3. Precise anatomical localization of accumulate places. 4. Reduction of the acquisition time. (Author)

  10. PET's indsats under lup

    DEFF Research Database (Denmark)

    Hansen, Peer Henrik

    2006-01-01

    En undersøgelseskommission nedsat i 1999. Fem medlemmer skal undersøge PET's efterretningsvirksomhed i forhold til politiske partier, faglige konflikter og politisk ideologiske bevægelser i Danmark under den kolde krig. Kommissionens rapport forventes færdig næste år. Udgivelsesdato: 2. juli 2006...

  11. PET CT and lymphomas

    International Nuclear Information System (INIS)

    Castro, R.

    2012-01-01

    This presentation is about Tc and lymphomas. Classification and clinical cases of various cancer such as gastro duodenal or ulcer, mama, medullary, lymph and neck, leukemia, nodular sclerosis. Metabolic information, anatomical nature of lymphoma and its clinical presentation determine the extent that PET should be used in the patient.

  12. Driving with pets and motor vehicle collision involvement among older drivers: A prospective population-based study.

    Science.gov (United States)

    Huisingh, Carrie; Levitan, Emily B; Irvin, Marguerite R; Owsley, Cynthia; McGwin, Gerald

    2016-03-01

    Distracted driving is a major cause of motor vehicle collision (MVC) involvement. Pets have been identified as potential distraction to drivers, particularly in the front. This type of distraction could be worse for those with impairment in the cognitive aspects of visual processing. The purpose of this study is to evaluate the association between driving with pets and rates of motor vehicle collision involvement in a cohort of older drivers. A three-year prospective study was conducted in a population-based sample of 2000 licensed drivers aged 70 years and older. At the baseline visit, a trained interviewer asked participants about pet ownership, whether they drive with pets, how frequently, and where the pet sits in the vehicle. Motor vehicle collision (MVC) involvement during the three-year study period was obtained from the Alabama Department of Public Safety. At-fault status was determined by the police officer who arrived on the scene. Participants were followed until the earliest of death, driving cessation, or end of the study period. Poisson regression was used to calculate crude and adjusted rate ratios (RR) examining the association between pet ownership, presence of a pet in a vehicle, frequency of driving with a pet, and location of the pet inside with vehicle with any and at-fault MVC involvement. We examined whether the associations differed by higher order visual processing impairment status, as measured by Useful Field of View, Trails B, and Motor-free Visual Perception Test. Rates of crash involvement were similar for older adults who have ever driven with a pet compared to those who never drove with their pet (RR=1.15, 95% CI 0.76-1.75). Drivers who reported always or sometimes driving with their pet had higher MVC rates compared to pet owners who never drive with a pet, but this association was not statistically significant (RR=1.39, 95% CI 0.86-2.24). In terms of location, those reporting having a pet frequently ride in the front of the vehicle

  13. THE PETS:Game Introduction of Pets in Two Languages

    Directory of Open Access Journals (Sweden)

    Wahyu Febriyanto

    2017-02-01

    Full Text Available Introducing environment is important for children. Included in this environment is the life of living beings such as humans, animals, and plants. The role of parents is needed in introducing the living creatures. One of the living creatures that endeared children are animals, especially the pets. Therefore made educational game The Pets. With the game "The Pets" is expected to help parents to teach the children in learning about pets based on place of living and food. In this paper describes how to design and create introducing pet game based on the type of food and its habitat in two different languages . "The Pets" has the Android platform with a minimum API Level 14 is created using the game engine Construct 2. Using two dimensional model and image with interesting coloring for children, and using the application CorelDraw X4. From results of the survey, "The Pets" can provide new knowledge and can assist children in learning about pets based on place of living and food. Children who previously could not mention animals vocabulary in English, after playing "The Pets" can name them into English.

  14. Resina pet para recipientes

    OpenAIRE

    Montenegro, Ricardo Sá Peixoto; Monteiro Filha, Dulce Corrêa; Pan, Simon Shi Koo

    1996-01-01

    O mercado potencial de resina PET para recipientes é grande, com ampla expectativa de expansão. A nível mundial, esta ocorrendo um ciclo de expansão que deverá levar a uma sobrecapacidade, pressionando os preços para baixo. No Brasil, a escassez de resina PET tem retardado sua maior utilização em recipientes, notadamente de bebidas carbonatadas e em mercados em desenvolvimento, como o de óleo comestível e água mineral. Com a entrada em operação da fábrica da Nitrocarbono e da expansão da Rhod...

  15. PET/MR in oncology

    DEFF Research Database (Denmark)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin

    2012-01-01

    After more than 20 years of research, a fully integrated PET/MR scanner was launched in 2010 enabling simultaneous acquisition of PET and MR imaging. Currently, no clinical indication for combined PET/MR has been established, however the expectations are high. In this paper we will discuss some...... of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number...... of different MRI techniques, such as DWI-MR (diffusion weighted imaging MR), DCE-MR (dynamic contrast enhanced MR), MRS (MR spectroscopy) and MR for attenuation correction of PET. All MR techniques presented in this paper have shown promising results in the treatment of patients with solid tumors and could...

  16. PET in lung cancer staging

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, R. E. [Duke University Medical Center, Dept. of Radiology, Durham, NC (United States)

    2001-09-01

    The primary clinical application of FDG-PET is in the evaluation of patients with lung cancer and includes diagnosis, staging and restaging of non-small cell lung cancer. PET has a very high accuracy (sensitivity=97%, specificity=78%) for characterizing nodules that are indeterminate by chest radiograph and computed tomography. The major utility of PET in the evaluation of patients with lung cancer is the staging of the entire body. PET is more accurate than the conventional imaging modalities of CT and bone scans in the detection of metastatic disease. PET is accurate in the staging of the mediastinum, adrenal glands, and the skeletal system. PET is not as accurate in the detection of brain metastases because of their small size and the normal cortical accumulation.

  17. Ingredients: where pet food starts.

    Science.gov (United States)

    Thompson, Angele

    2008-08-01

    Every clinician is asked "What should I feed my pet?" Understanding the ingredients in pet food is an important part of making the best recommendation. Pet food can be as simple as one ingredient or as complicated as containing more than 60 ingredients. Pet food and its ingredients are regulated by the Food and Drug Administration and state feed officials. Part of that regulation is the review and definition of ingredients. Existing ingredients change and new ingredients become available so the need for ingredient definitions grows. Ingredients for product formulations are chosen based on their nutrient content, digestibility, palatability, functionality, availability, and cost. As an example, a typical, nutritionally complete dry dog food with 42 ingredients is examined and the ingredients are discussed here. Safe, healthy pet food starts with safe ingredients sourced from well-monitored suppliers. The ultimate goal of both veterinarians and pet food manufacturers is the same--long healthy lives for dogs and cats.

  18. Usage of Recycled Pet

    OpenAIRE

    A. Ebru Tayyar; Sevcan Üstün

    2010-01-01

    The increasing industrialization, urbanization and the technological development have caused to increase depletion of the natural resources and environmental pollution's problem. Especially, for the countries which have not enough space recycling of the waste eliminating waste on regular basis or decreasing the amount and volume of waste have provided the important advantages. There are lots of studies and projects to develop both protect resources and prevent environmental pollution. PET bot...

  19. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull. 2007; 6(4: 307-312

  20. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull 2007; 6(4.000: 307-312

  1. Pet Overpopulation: An Economic Analysis

    OpenAIRE

    Stephen Coate; Brian Knight

    2009-01-01

    This paper considers the problem of pet overpopulation. It develops a tractable dynamic model whose positive predictions square well with key features of the current U.S. market for pets. The model is used to understand, from a welfare economic perspective, the sense in which there is \\overpopulation" of pets and the underlying causes of the problem. The paper also employs the model to consider what policies might be implemented to deal with the problem. A calibrated example is developed to i...

  2. PET kinetic analysis. Compartmental model

    International Nuclear Information System (INIS)

    Watabe, Hiroshi; Ikoma, Yoko; Shidahara, Miho; Kimura, Yuichi; Naganawa, Mika

    2006-01-01

    Positron emission tomography (PET) enables not only visualization of the distribution of radiotracer, but also has ability to quantify several biomedical functions. Compartmental model is a basic idea to analyze dynamic PET data. This review describes the principle of the compartmental model and categorizes the techniques and approaches for the compartmental model according to various aspects: model design, experimental design, invasiveness, and mathematical solution. We also discussed advanced applications of the compartmental analysis with PET. (author)

  3. Read the Label First: Protect Your Pets

    Science.gov (United States)

    Learn about the importance of reading pet products labels before purchasing and using any product to insure the safety of your pets. Find tips for ways to reduce the changes of pets accessing potentially dangerous products.

  4. Cyclotron/PET project in Uruguay

    International Nuclear Information System (INIS)

    Engler, H.

    2006-01-01

    The Positron Computed Tomography (PET) is a tri dimensional image technique which shows biochemical information. PET is used in neurology and cardiology diseases. The National Center Cyclotron PET has been found to research, development and health science applications.

  5. Creating Fido's twin: can pet cloning be ethically justified?

    Science.gov (United States)

    Fiester, Autumn

    2005-01-01

    Taken at face value, pet cloning may seem at best a frivolous practice, costly both to the cloned pet's health and its owner's pocket. At worst, its critics say, it is misguided and unhealthy--a way of exploiting grief to the detriment of the animal, its owner, and perhaps even animal welfare in general. But if the great pains we are willing to take to clone Fido raise the status of companion animals in the public eye, then the practice might be defensible.

  6. The emerging disease occurrence of pet animals in Bangladesh

    Directory of Open Access Journals (Sweden)

    Umma Habiba

    2016-12-01

    Results: Among the most general pet animals in Bangladesh (dog, cat, rabbit, the mostly occured diseases were scabies (23.07%, feline ascariasis (37.14% and rabbit mange (34.61%, while the less frequent diseases were canine parvovirus enteritis (2.19%, cat scratch disease (5.71% and overgrown teeth (7.69%. Conclusion: The study provides basic information about the current status and the percentage (% of disease occurrence considering the emerging diseases of pet animals in Bangladesh. [J Adv Vet Anim Res 2016; 3(4.000: 413-419

  7. The impact of PET-CT in suspected recurrent ovarian cancer: A prospective multi-centre study as part of the Australian PET Data Collection Project.

    Science.gov (United States)

    Fulham, M J; Carter, J; Baldey, A; Hicks, R J; Ramshaw, J E; Gibson, M

    2009-03-01

    To assess the impact of FDG PET-CT on the management of patients with suspected recurrent ovarian cancer and to determine the incremental information provided by PET-CT. This was a prospective, multi-centre, cohort study. Ninety women (mean age 59.9 years; age range 35-85 years) with a previous history of treated epithelial ovarian carcinoma and suspected recurrence based on elevated CA-125, anatomical imaging or clinical symptoms were studied with FDG PET-CT across two States. Referring doctors were asked to specify a management plan pre-PET, if management was altered after PET-CT and, the impact (rated - none, low, medium, high) of PET-CT on patient management. The pre-PET management plan could include radiotherapy, chemotherapy, surgery, and 'other' including observation. Patients were followed at 6 and 12 months and clinical status, evidence of recurrence and progression were recorded. Patients were referred by 34 individual specialists. At least 168 additional sites of disease in 61 patients (68%), not identified by conventional imaging were identified by PET-CT. In 77% the additional lesions were located below the diaphragm and most were nodal or peritoneal. PET-CT affected management in 60% (49% high, 11% medium impact). Patients where more disease was detected with PET-CT were more likely to progress in the following 12 months. For women with previously treated ovarian carcinoma with recurrent disease, PET-CT can: a) alter management in close to 60% of patients, b) detect more sites of disease than abdominal and pelvic CT, c) is superior in the detection of nodal, peritoneal and subcapsular liver disease and d) offers the opportunity for technology replacement in this setting.

  8. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4.......7) min(-1), P PET...

  9. PET and PET/CT - clinical value in lung cancer; PET und PET/CT - Stellenwert beim Lungenkarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Klinik und Poliklinik fuer Nukearmedizin, Dept. Medizinische Radiologie, Univ. Zuerich (Switzerland)

    2004-12-01

    Preoperative staging of lung cancer is essential for prognosis and management. The aim of this overview is to present the synergistic effects of FDG-PET and CT. For planning surgery and planning radiation treatment the precise definition of the tumor extend is essential. Integrated PET/CT scanning enables the exact localization of tumor infiltration into surrounding tissue and of small metastases. In this overview the applications of PET and PET/CT in non-small-cell lung cancer, small-cell lung cancer and malignant pleural mesothelioma are presented. (orig.)

  10. Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Shu-Hang [Chang Gung Memorial Hospital Linkou Medical Center, Molecular Imaging Center and Department of Diagnostic Radiology, Kueishan (China)]|[Chang Gung Memorial Hospital, Linkou Medical Center, Department of Diagnostic Radiology, Kueishan, Taoyuan (China); Chan, Sheng-Chieh; Yen, Tzu-Chen; Liu, Feng-Yuan [Chang Gung Memorial Hospital Linkou Medical Center, Department of Nuclear Medicine, Kueishan (China); Chang, Joseph Tung-Chieh; Fan, Kang-Hsing [Chang Gung Memorial Hospital Linkou Medical Center, Department of Radiation Oncology, Kueishan (China); Liao, Chun-Ta [Chang Gung Memorial Hospital Linkou Medical Center, Department of Otorhinolaryngology, Kueishan (China); Ko, Sheung-Fat; Chin, Shu-Chyn [Chang Gung Memorial Hospital Linkou Medical Center, Molecular Imaging Center and Department of Diagnostic Radiology, Kueishan (China); Hsu, Cheng-Lung [Chang Gung Memorial Hospital Linkou Medical Center, Department of Medical Oncology, Kueishan (China)

    2009-01-15

    We prospectively compared PET/CT and conventional imaging for initial staging of nasopharyngeal carcinoma (NPC). A total of 111 patients with histologically proven NPC were investigated with PET/CT and conventional imaging (head-and-neck MRI, chest X-ray, abdominal ultrasound, and bone scan) before treatment. The respective findings were reviewed independently and then compared with each other. With regard to T staging, PET/CT showed a discrepancy with head-and-neck MRI in 36 (32.4%) of the study subjects. With regard to N staging, PET/CT showed a discrepancy with head-and-neck MRI in 15 (13.5%) patients. Among the discordant cases, MRI was superior in demonstrating tumor involvement in the parapharyngeal space, skull base, intracranial area, sphenoid sinus, and retropharyngeal nodes while PET/CT was superior in demonstrating neck nodal metastasis. PET/CT disclosed 13 of 16 patients with distant malignancy compared with four patients disclosed by conventional imaging work-up. The false-positive rate of PET/CT was 18.8%. PET/CT correctly modified M staging in eight patients (7.2%) and disclosed a second primary lung malignancy in one patient (0.9%). In NPC patients, MRI appears to be superior to PET/CT for the assessment of locoregional invasion and retropharyngeal nodal metastasis. PET/CT is more accurate than MRI for determining cervical nodal metastasis and should be the better reference for the neck status. PET/CT has an acceptable diagnostic yield and a low false-positive rate for the detection of distant malignancy and can replace conventional work-up to this aim. PET/CT and head-and-neck MRI are suggested for the initial staging of NPC patients. (orig.)

  11. Value of retrospective image fusion of 18F-FDG PET and MRI for preoperative staging of head and neck cancer: Comparison with PET/CT and contrast-enhanced neck MRI

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Kitajima, Kazuhiro; Suenaga, Yuko; Konishi, Jyunya; Sasaki, Ryohei; Morimoto, Koichi; Saito, Miki; Otsuki, Naoki; Nibu, Ken-ichi; Sugimura, Kazuro

    2013-01-01

    Purpose: To assess the clinical value of retrospective image fusion of neck MRI and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET for locoregional extension and nodal staging of neck cancer. Materials and methods: Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated. Results: Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant. Conclusion: Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer

  12. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  13. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with {sup 18}F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Suenaga, Yuko; Ueno, Yoshiko [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Kanda, Tomonori [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Maeda, Tetsuo; Takahashi, Satoru [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University School of Medicine, Kobe (Japan)

    2013-10-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer.

  14. Neurotransmission imaging by PET

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Akihiro; Suhara, Tetsuya [National Inst. of Radiological Sciences, Chiba (Japan)

    2001-08-01

    PET studies on neurotransmission in psychological disorders to evaluate abnormal neurotransmission and therapeutic effects are thoroughly reviewed by type of major neurotransmitters. Studies on dopaminergic neurotransmission have focused on the function of dopamine D{sub 2} receptors, receptor subtypes, such as the D{sub 1} receptor, and ligands, such as transporters. PET studies of dopamine D{sub 2} receptor, which began in the early 1980s, have predominantly been performed in schizophrenia, and most have failed to detect any statistically significant differences between schizophrenia patients and controls. The studies in the early 1980s were performed by using [{sup 11}C]N-methyl-spiperone (NMSP) and [{sup 11}C]raclopride, ligands for striatal dopamine D{sub 2} receptors. [{sup 11}C]FLB457, which has much higher affinity for D{sub 2} receptors than raclopride, began to be used in the 1990s. Dopamine D{sub 2} occupancy after drug ingestion has also been investigated to clarify the mechanisms and effects of antipsychotic drugs, and there have also been studies on the effect of aging and personality traits on dopamine D{sub 2} receptor levels in healthy subjects. In studies on dopamine receptor subtypes other than D{sub 2}, dopamine D{sub 1} receptors have been studied in connection with assessments of cognitive functions. Most studies on dopamine transporters have been related to drug dependence. Serotonin 5-HT{sub 2A} receptors have been studied with [{sup 11}C]NMSP in schizophrenia patients, while studies of another serotonin receptor subtype, 5-HT{sub 1A} receptors, have been mainly conducted in patients with depression. [{sup 11}C]NMSP PET showed no difference between schizophrenia patients who had not undergone phamacotherapy and normal subjects. Because serotonin selective reuptake inhibitors (SSRIs) affect serotonin transporters, and abnormalities in serotonin transporters detected in mood disorders, PET ligands for serotonin transporters have increasingly

  15. Neurotransmission imaging by PET

    International Nuclear Information System (INIS)

    Takano, Akihiro; Suhara, Tetsuya

    2001-01-01

    PET studies on neurotransmission in psychological disorders to evaluate abnormal neurotransmission and therapeutic effects are thoroughly reviewed by type of major neurotransmitters. Studies on dopaminergic neurotransmission have focused on the function of dopamine D 2 receptors, receptor subtypes, such as the D 1 receptor, and ligands, such as transporters. PET studies of dopamine D 2 receptor, which began in the early 1980s, have predominantly been performed in schizophrenia, and most have failed to detect any statistically significant differences between schizophrenia patients and controls. The studies in the early 1980s were performed by using [ 11 C]N-methyl-spiperone (NMSP) and [ 11 C]raclopride, ligands for striatal dopamine D 2 receptors. [ 11 C]FLB457, which has much higher affinity for D 2 receptors than raclopride, began to be used in the 1990s. Dopamine D 2 occupancy after drug ingestion has also been investigated to clarify the mechanisms and effects of antipsychotic drugs, and there have also been studies on the effect of aging and personality traits on dopamine D 2 receptor levels in healthy subjects. In studies on dopamine receptor subtypes other than D 2 , dopamine D 1 receptors have been studied in connection with assessments of cognitive functions. Most studies on dopamine transporters have been related to drug dependence. Serotonin 5-HT 2A receptors have been studied with [ 11 C]NMSP in schizophrenia patients, while studies of another serotonin receptor subtype, 5-HT 1A receptors, have been mainly conducted in patients with depression. [ 11 C]NMSP PET showed no difference between schizophrenia patients who had not undergone phamacotherapy and normal subjects. Because serotonin selective reuptake inhibitors (SSRIs) affect serotonin transporters, and abnormalities in serotonin transporters detected in mood disorders, PET ligands for serotonin transporters have increasingly been developed, and serotonin transporters have recently begun to be

  16. Small Molecule PET-Radiopharmaceuticals

    NARCIS (Netherlands)

    Elsinga, Philip H.; Dierckx, Rudi A. J. O.

    This review describes several aspects required for the development of small molecule PET-tracers. Design and selection criteria are important to consider before starting to develop novel PET-tracers. Principles and latest trends in C-11 and F-18-radiochemistry are summarized. In addition an update

  17. Welfare assessment in pet rabbits

    NARCIS (Netherlands)

    Schepers, F.; Koene, P.; Beerda, B.

    2009-01-01

    One million pet rabbits are kept in The Netherlands, but there are no data available on their behaviour and welfare. This study seeks to assess the welfare of pet rabbits in Dutch households and is a first step in the development of a welfare assessment system. In an internet survey, housing

  18. Pet Ownership: A Research Note.

    Science.gov (United States)

    Lawton, M. Powell; And Others

    1984-01-01

    Data from a 1968 national sample of older people (N=3,996) indicated that pet ownership was more frequent in owner-occupied residences in smaller communities where other family, including children were present. No association was found between pet ownership and psychological well-being or health. (Author)

  19. Selecting Safe Pets (For Parents)

    Science.gov (United States)

    ... because you can buy a pet from the pet store doesn't mean it's safe for homes with kids. Animals that may not be child-safe include: reptiles (turtles, snakes, lizards, iguanas) rodents (hamsters, gerbils, guinea pigs, chinchillas, hedgehogs, prairie ...

  20. Supplements for exotic pets.

    Science.gov (United States)

    Mejia-Fava, Johanna; Colitz, Carmen M H

    2014-09-01

    The use of supplements has become commonplace in an effort to complement traditional therapy and as part of long-term preventive health plans. This article discusses historical and present uses of antioxidants, vitamins, and herbs. By complementing traditional medicine with holistic and alternative nutrition and supplements, the overall health and wellness of exotic pets can be enhanced and balanced. Further research is needed for understanding the strengths and uses of supplements in exotic species. Going back to the animals' origin and roots bring clinicians closer to nature and its healing powers. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Easy fast PET chemistry

    International Nuclear Information System (INIS)

    Ehrenkaufer, R.L.E.

    1989-01-01

    PET radiopharmaceutical chemists are continually stressed by the dichotomy between the ever increasing complexity of radiopharmaceuticals demanded of them vs. the unrelenting physical constraints of short half-life and high annihilation gamma energy inherent in these positron emitting isotopes. This paper is dedicated to those who have approached this challenge with cleverness, innovation and a smile. Areas to be discussed will include development and uses of precursors, radiochemistry with very short-lived isotopes (T1/2 ≤ 2 min) and physical/mechanical approaches to meeting synthetic demands

  2. Investigations of Pet Animal Breeding Trends in Sivas

    Directory of Open Access Journals (Sweden)

    Yusuf Ziya Oğrak

    2014-04-01

    Full Text Available The aim of the study was to determine the present situation and future trends of pet which a member of our home in central Anatolian city of Sivas. For this purpose, 100 people (73 male, 27 female used with face to face interviews in the questionnaire aged 18-72 (mean 32.25, monthly income changed 400-5000 Turkish Liras (average 1841 and, 16 questions except for personal information were asked to participants. Participants, 51% graduated the university, 46% married, 82% lived in apartments, and 64% of the occupied own houses or belonging to their family have been identified. According to the findings, any breeders of pet in the house in Sivas rate were 31%. and, the people's income level , gender , age , marital status , educational level , having a child and the seat of the house with a garden and the lack of this on the ratio statistically not significant was observed. Highest percentage pet in species of breeding animals was the bird and, 48.4% of those pet owners did not go to the veterinarian at all and, 24.6% of non-animal’s previously had a bad incident with animals that have been identified. As a result, in terms of veterinary importance will increase day by day with pet animal breeding priorities for the further dissemination of the determination of the current situation and problems are seen to be important and, larger-scale research to be done will be helpful.

  3. Non FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, C., E-mail: cristina.nanni@aosp.bo.i [Nuclear Medicine Unit, Policlinico S.Orsola, University of Bologna, Bologna (Italy); Fantini, L.; Nicolini, S.; Fanti, S. [Nuclear Medicine Unit, Policlinico S.Orsola, University of Bologna, Bologna (Italy)

    2010-07-15

    2- [{sup 18}F]-fluoro-2-deoxy-D-glucose (FDG) is the radiopharmaceutical most frequently used for clinical positron emission tomography (PET). However, FDG cannot be used for many oncological, cardiological, or neurological conditions, either because the abnormal tissue does not concentrate it, or because the tissues under investigation demonstrate high physiological glucose uptake. Consequently, alternative PET tracers have been produced and introduced into clinical practice. The most important compounds in routine practice are {sup 11}C-choline and {sup 18}F-choline, mainly for the evaluation of prostate cancer; {sup 1}C-methionine for brain tumours; {sup 118}F-DOPA ({sup 18}F- deoxiphenilalanine) for neuroendocrine tumours and movement disorders; {sup 68}Ga-DOTANOC (tetraazacyclododecanetetraacetic acid-[1-Nal3]-octreotide) and other somatostatin analogues for neuroendocrine tumours; 11C-acetate for prostate cancer and hepatic masses and 18F-FLT (3'-deoxy-3'-fluorothymidine) for a number of malignant tumours. Another impetus for the development of new tracers is to enable the investigation of biological processes in tumours other than glucose metabolism. This is especially important in the field of response assessment, where there are new agents that are targeted more specifically at angiogenesis, hypoxia, apoptosis and other processes.

  4. Neuropsychiatry: PET and SPECT

    International Nuclear Information System (INIS)

    Quintana F, Juan Carlos

    2002-01-01

    Functional brain imaging with PET and SPECT have a definitive and well established role in the investigation of a variety of conditions such as dementia, epilepsy and drug addiction. With these methods it is possible to detect early rCBF (regional Cerebral Blood Flow) changes seen in dementia (even before clinical symptoms) and differentiate Alzheimer's disease from other dementias by means of the rCBF pattern change. 18-F-FDG PET imaging is a useful tool in partial epilepsy because both rCBF and brain metabolism are compromised at the epileptogenic focus. During the seizure, rCBF dramatically increases locally. Using SPECT it is possible to locate such foci with 97% accuracy. In drug addiction, particularly with cocaine, functional imaging has proven to be very sensitive to detect brain flow and metabolism derangement early in the course of this condition. These findings are important in many ways: prognostic value, they are used as a powerful reinforcement tool and to monitor functional recovery with rehabilitation. There are many other conditions in which functional brain imaging is of importance such as acute stroke treatment assessment, trauma rehabilitation and in psychiatric and abnormal movement diseases specially with the development of receptor imaging (au)

  5. FDG PET imaging dementia

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol [Kyungpook National University Medical School and Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2007-04-15

    Dementia is a major burden for many countries including South Korea, where life expectancy is continuously growing and the proportion of aged people is rapidly growing. Neurodegenerative disorders, such as, Alzheimer disease, dementia with Lewy bodies, frontotemporal dementia. Parkinson disease, progressive supranuclear palsy, corticobasal degeneration, Huntington disease, can cause dementia, and cerebrovascular disease also can cause dementia. Depression or hypothyroidism also can cause cognitive deficits, but they are reversible by management of underlying cause unlike the forementioned dementias. Therefore these are called pseudodementia. We are entering an era of dementia care that will be based upon the identification of potentially modifiable risk factors and early disease markers, and the application of new drugs postpone progression of dementias or target specific proteins that cause dementia. Efficient pharmacologic treatment of dementia needs not only to distinguish underlying causes of dementia but also to be installed as soon as possible. Therefore, differential diagnosis and early diagnosis of dementia are utmost importance. F-18 FDG PET is useful for clarifying dementing diseases and is also useful for early detection of the disease. Purpose of this article is to review the current value of FDG PET for dementing diseases including differential diagnosis of dementia and prediction of evolving dementia.

  6. 7 CFR 502.11 - Pets.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...

  7. PET/MRI in cancer patients

    DEFF Research Database (Denmark)

    Kjær, Andreas; Loft, Annika; Law, Ian

    2013-01-01

    Medicine & PET at Rigshospitalet in Copenhagen we installed an integrated PET/MRI in December 2011. Here, we describe our first clinical PET/MR cases and discuss some of the areas within oncology where we envision promising future application of integrated PET/MR imaging in clinical routine. Cases...

  8. Gamma camera based FDG PET in oncology

    International Nuclear Information System (INIS)

    Park, C. H.

    2002-01-01

    Positron Emission Tomography(PET) was introduced as a research tool in the 1970s and it took about 20 years before PET became an useful clinical imaging modality. In the USA, insurance coverage for PET procedures in the 1990s was the turning point, I believe, for this progress. Initially PET was used in neurology but recently more than 80% of PET procedures are in oncological applications. I firmly believe, in the 21st century, one can not manage cancer patients properly without PET and PET is very important medical imaging modality in basic and clinical sciences. PET is grouped into 2 categories; conventional (c) and gamma camera based ( CB ) PET. CB PET is more readily available utilizing dual-head gamma cameras and commercially available FDG to many medical centers at low cost to patients. In fact there are more CB PET in operation than cPET in the USA. CB PET is inferior to cPET in its performance but clinical studies in oncology is feasible without expensive infrastructures such as staffing, rooms and equipments. At Ajou university Hospital, CBPET was installed in late 1997 for the first time in Korea as well as in Asia and the system has been used successfully and effectively in oncological applications. Our was the fourth PET operation in Korea and I believe this may have been instrumental for other institutions got interested in clinical PET. The following is a brief description of our clinical experience of FDG CBPET in oncology

  9. Whole-body PET/MRI

    DEFF Research Database (Denmark)

    Aznar, M C; Sersar, Rachida; Saabye, J

    2014-01-01

    PURPOSE: In combined PET/MRI standard PET attenuation correction (AC) is based on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not represented. We evaluate PET quantification in whole-body (WB)-PET/MRI following MR-AC without considering bone attenuation...

  10. Pet food recalls and pet food contaminants in small animals.

    Science.gov (United States)

    Bischoff, Karyn; Rumbeiha, Wilson K

    2012-03-01

    Most pet foods are safe, but incidents of chemical contamination occur and lead to illness and recalls. There were 11 major pet food recalls in the United States between 1996 and 2010 that were due to chemical contaminants or misformulations: 3 aflatoxin, 3 excess vitamin D3, 1 excess methionine, 3 inadequate thiamine, and 1 adulteration with melamine and related compounds and an additional 2 warnings concerning a Fanconilike renal syndrome in dogs after ingesting large amounts of chicken jerky treat products. This article describes clinical findings and treatment of animals exposed to the most common pet food contaminants.

  11. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  12. Pet ownership may attenuate loneliness among older adult primary care patients who live alone.

    Science.gov (United States)

    Stanley, Ian H; Conwell, Yeates; Bowen, Connie; Van Orden, Kimberly A

    2014-01-01

    Older adults who report feelings of loneliness are at increased risk for a range of negative physical and mental health outcomes, including early mortality. Identifying potential sources of social connectedness, such as pet ownership, could add to the understanding of how to promote health and well-being in older adults. The aim of this study is to describe the association of pet ownership and loneliness. The current study utilizes cross-sectional survey data from a sample (N = 830) of older adult primary care patients (age ≥ 60 years). Pet owners were 36% less likely than non-pet owners to report loneliness, in a model controlling for age, living status (i.e., alone vs. not alone), happy mood, and seasonal residency (adjOR = 0.64, 95% CI = 0.41-0.98, p pet ownership and living status (b = -1.60, p owning a pet was associated with the greatest odds of reporting feelings of loneliness. The findings suggest that pet ownership may confer benefits for well-being, including attenuating feelings of loneliness and its related sequelae, among older adults who live alone.

  13. Pet ownership and physical health.

    Science.gov (United States)

    Matchock, Robert L

    2015-09-01

    Pet ownership and brief human-animal interactions can serve as a form of social support and convey a host of beneficial psychological and physiological health benefits. This article critically examines recent relevant literature on the pet-health connection. Cross-sectional studies indicate correlations between pet ownership and numerous aspects of positive health outcomes, including improvements on cardiovascular measures and decreases in loneliness. Quasi-experimental studies and better controlled experimental studies corroborate these associations and suggest that owning and/or interacting with a pet may be causally related to some positive health outcomes. The value of pet ownership and animal-assisted therapy (AAT), as a nonpharmacological treatment modality, augmentation to traditional treatment, and healthy preventive behavior (in the case of pet ownership), is starting to be realized. However, more investigations that employ randomized controlled trials with larger sample sizes and investigations that more closely examine the underlying mechanism of the pet-health effect, such as oxytocin, are needed.

  14. PET and PET/CT in tumour of undetermined origin

    International Nuclear Information System (INIS)

    Garcia O, J.R.

    2007-01-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  15. Neutering of cats and dogs in Ireland; pet owner self-reported perceptions of enabling and disabling factors in the decision to neuter

    Directory of Open Access Journals (Sweden)

    Martin J. Downes

    2015-08-01

    Full Text Available Background. Failure among pet owners to neuter their pets results in increased straying and overpopulation problems. Variations in neutering levels can be explained by cultural differences, differences in economic status in rural and urban locations, and owner perceptions about their pet. There are also differences between male and female pet owners. There is no research pertaining to Irish pet owner attitudes towards neutering their pets. This paper identified the perceptions of a sample of Irish cat and dog owners that influenced their decisions on pet neutering.Methods. This study was conducted using social science (qualitative methods, including an interview-administered survey questionnaire and focus group discussions. Data was coded and managed using Nvivo 8 qualitative data analysis software.Results. Focus groups were conducted with 43 pet (cats and dogs owners. Two major categories relating to the decision to neuter were identified: (1 enabling perceptions in the decision to neuter (subcategories were: controlling unwanted pet behaviour; positive perceptions regarding pet health and welfare outcomes; perceived owner responsibility; pet function; and the influence of veterinary advice, and (2 disabling perceptions in the decision to neuter (subcategories were: perceived financial cost of neutering; perceived adequacy of existing controls; and negative perceptions regarding pet health and welfare outcomes.Discussion. Pet owner sense of responsibility and control are two central issues to the decision to neuter their pets. Understanding how pet owners feel about topics such as pet neutering, can help improve initiatives aimed at emphasising the responsibility of population control of cats and dogs.

  16. PET/TAC in Oncology; PET/TAC en Oncologia

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez V, A.M. [Especialista en Medicina Nuclear, Profa. Depto. Radiologia de la Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain)

    2007-07-01

    From this presentation of PET-TAC in oncology the following advantages on the conventional PET are obtained: 1. More short study and stadium in one session. 2. It adds the information of both techniques. 3. Better localization of leisure: affected organ, stadium change (neck, mediastinum, abdomen). 4. Reduction of false positive (muscle, brown fat, atelectasis, pneumonias, intestine, urinary vials, etc.). 5. Reduction of negative false. 6. Reduction of not conclusive. 7. More understandable for other specialists. 8. Biopsies guide. 9. Planning radiotherapy.

  17. Veterinarians' role for pet owners facing pet loss

    Science.gov (United States)

    Fernandez-Mehler, P.; Gloor, P.; Sager, E.; Lewis, F. I.; Glaus, T. M

    2013-01-01

    Owners' satisfaction with, and expectations from, their veterinarians around euthanasia, including questions on disposal of pet remains subject to animal species, clients' gender, age, family conditions, area of living and type of veterinary clinic visited were evaluated by questionnaire. Questionnaires were to be filled out by clients consecutively visiting the individual practices and hospitals for any kind of consultations. Of 2350 questionnaires distributed, 2008 were returned and available for analysis. Owner satisfaction concerning the procedure of euthanasia was high (92 per cent, 1173/1272). After the event of euthanasia, 14 per cent (170/1250) had changed their veterinarian, even though 75 per cent of these 170 had been satisfied with the procedure. Most owners (88 per cent) expected veterinarians to talk about their pet's final destination, and 38 per cent expected this to happen early in the pet's life. For 81 per cent clients, the veterinarian was the primary informant about the possibilities concerning the disposal of pet remains, and 33 per cent indicated their veterinarian as the contact person to talk about pet loss. Area of living, or veterinary specialisation, only marginally influenced the answers. Veterinarians play an important role to inform their clients concerning questions around euthanasia and the care of pet remains, and to support them during the process of mourning. PMID:23492929

  18. Veterinarians' role for pet owners facing pet loss.

    Science.gov (United States)

    Fernandez-Mehler, P; Gloor, P; Sager, E; Lewis, F I; Glaus, T M

    2013-05-25

    Owners' satisfaction with, and expectations from, their veterinarians around euthanasia, including questions on disposal of pet remains subject to animal species, clients' gender, age, family conditions, area of living and type of veterinary clinic visited were evaluated by questionnaire. Questionnaires were to be filled out by clients consecutively visiting the individual practices and hospitals for any kind of consultations. Of 2350 questionnaires distributed, 2008 were returned and available for analysis. Owner satisfaction concerning the procedure of euthanasia was high (92 per cent, 1173/1272). After the event of euthanasia, 14 per cent (170/1250) had changed their veterinarian, even though 75 per cent of these 170 had been satisfied with the procedure. Most owners (88 per cent) expected veterinarians to talk about their pet's final destination, and 38 per cent expected this to happen early in the pet's life. For 81 per cent clients, the veterinarian was the primary informant about the possibilities concerning the disposal of pet remains, and 33 per cent indicated their veterinarian as the contact person to talk about pet loss. Area of living, or veterinary specialisation, only marginally influenced the answers. Veterinarians play an important role to inform their clients concerning questions around euthanasia and the care of pet remains, and to support them during the process of mourning.

  19. Pets and the immunocompromised person

    Science.gov (United States)

    ... can get infections, such as toxoplasmosis, by eating wild animals. DO NOT let your pet drink from the ... bird's cage. Other important tips: DO NOT adopt wild or exotic animals. These animals are more likely to bite. They ...

  20. Disaster Preparedness for Your Pet

    Science.gov (United States)

    ... Keep a leash and/or carrier nearby the exit. Ensure proper equipment for pets to ride in ... also carry a variety of diseases (Lyme disease, West Nile virus) harmful to both humans and animals. ...

  1. PET and PET/CT in tumour of undetermined origin; PET y PET/CT en tumor de origen indeterminado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia O, J.R. [Nuclear Medicine and Molecular Imaging, PET/CT, Centro Medico ABC, Mexico D.F. (Mexico)

    2007-07-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  2. Radiation monitoring of PET staff

    International Nuclear Information System (INIS)

    Trang, A.

    2004-01-01

    Full text: Positron emission tomography (PET) is becoming a common diagnostic tool in hospitals, often located in and employing staff from the Nuclear Medicine or Radiology departments. Although similar in some ways, staff in PET departments are commonly found to have the highest radiation doses in the hospital environment due to unique challenges which PET tracers present in administration as well as production. The establishment of a PET centre with a dedicated cyclotron has raised concerns of radiation protection to the staff at the WA PET Centre and the Radiopharmaceutical Production and Development (RAPID) team. Since every PET centre has differing designs and practices, it was considered important to closely monitor the radiation dose to our staff so that improvements to practices and design could be made to reduce radiation dose. Electronic dosimeters (MGP DMC 2000XB), which have a facility to log time and dose at 10 second intervals, were provided to three PET technologists and three PET nurses. These were worn in the top pocket of their lab coats throughout a whole day. Each staff member was then asked to note down their duties throughout the day and also note the time they performed each duty. The duties would then correlate with the dose with which the electronic monitor recorded and an estimate of radiation dose per duty could be given. Also an estimate of the dose per day to each staff member could be made. PET nurses averaged approximately 20 μ8v per day getting their largest dose from caring for occasional problematic patients. Smaller doses of a 1-2 μ8v were recorded for injections and removing cannulas. PET technologists averaged approximately 15 μ8v per day getting their largest dose of 1-5μ8v mainly from positioning of patients and sometimes larger doses due to problematic patients. Smaller doses of 1-2 μ5v were again recorded for injections and removal of cannulas. Following a presentation given to staff, all WA PET Centre and RAPID staff

  3. PET/TAC in Oncology

    International Nuclear Information System (INIS)

    Jimenez V, A.M.

    2007-01-01

    From this presentation of PET-TAC in oncology the following advantages on the conventional PET are obtained: 1. More short study and stadium in one session. 2. It adds the information of both techniques. 3. Better localization of leisure: affected organ, stadium change (neck, mediastinum, abdomen). 4. Reduction of false positive (muscle, brown fat, atelectasis, pneumonias, intestine, urinary vials, etc.). 5. Reduction of negative false. 6. Reduction of not conclusive. 7. More understandable for other specialists. 8. Biopsies guide. 9. Planning radiotherapy

  4. PET imaging in pediatric oncology

    International Nuclear Information System (INIS)

    Shulkin, B.L.

    2004-01-01

    High-quality PET imaging of pediatric patients is challenging and requires attention to issues commonly encountered in the practice of pediatric nuclear medicine, but uncommon to the imaging of adult patients. These include intravenous access, fasting, sedation, consent, and clearance of activity from the urinary tract. This paper discusses some technical differences involved in pediatric PET to enhance the quality of scans and assure the safety and comfort of pediatric patients. (orig.)

  5. Nutritional sustainability of pet foods.

    Science.gov (United States)

    Swanson, Kelly S; Carter, Rebecca A; Yount, Tracy P; Aretz, Jan; Buff, Preston R

    2013-03-01

    Sustainable practices meet the needs of the present without compromising the ability of future generations to meet their needs. Applying these concepts to food and feed production, nutritional sustainability is the ability of a food system to provide sufficient energy and essential nutrients required to maintain good health in a population without compromising the ability of future generations to meet their nutritional needs. Ecological, social, and economic aspects must be balanced to support the sustainability of the overall food system. The nutritional sustainability of a food system can be influenced by several factors, including the ingredient selection, nutrient composition, digestibility, and consumption rates of a diet. Carbon and water footprints vary greatly among plant- and animal-based ingredients, production strategy, and geographical location. Because the pet food industry is based largely on by-products and is tightly interlinked with livestock production and the human food system, however, it is quite unique with regard to sustainability. Often based on consumer demand rather than nutritional requirements, many commercial pet foods are formulated to provide nutrients in excess of current minimum recommendations, use ingredients that compete directly with the human food system, or are overconsumed by pets, resulting in food wastage and obesity. Pet food professionals have the opportunity to address these challenges and influence the sustainability of pet ownership through product design, manufacturing processes, public education, and policy change. A coordinated effort across the industry that includes ingredient buyers, formulators, and nutritionists may result in a more sustainable pet food system.

  6. Game Design to Introduce Pets

    Directory of Open Access Journals (Sweden)

    Wahyu Febriyanto

    2017-02-01

    Full Text Available Introduction of animals from an early age can make children to love animals, especially pets. Children are the easiest group to receive stimulation, such as for example the stimulation of introducing children to the pet. Various media are used by parents to introduce pet. For examplle, by the media of books, multimedia, etc. One of the interesting media to introduce pet is with game. Of these problems then need to know how to make concept and design game to introduced pets for children age 3-6 years. In this paper, author formulate how to make pet game design include game genre, user interface design, image model selection, game characters, and game engine. The expected design of this game can be formulation of learning through proper game as a learning tool children. Game design derived from this writing by using model 2-dimensional images are funny and interesting coloring. And combines several game genres into one, or use the mini games that children do not get bored quickly. Design of GUI (Graphical User Interface is made as simple as possible so that children easily understand in playing this game, but also must use an interesting image

  7. Are Pets in the Bedroom a Problem?

    Science.gov (United States)

    Krahn, Lois E; Tovar, M Diane; Miller, Bernie

    2015-12-01

    The presence of pets in the bedroom can alter the sleep environment in ways that could affect sleep. Data were collected by questionnaire and interview from 150 consecutive patients seen at the Center for Sleep Medicine, Mayo Clinic in Arizona. Seventy-four people (49%) reported having pets, with 31 (41% of pet owners) having multiple pets. More than half of pet owners (56%) allowed their pets to sleep in the bedroom. Fifteen pet owners (20%) described their pets as disruptive, whereas 31 (41%) perceived their pets as unobtrusive or even beneficial to sleep. Health care professionals working with patients with sleep concerns should inquire about the presence of companion animals in the sleep environment to help them find solutions and optimize their sleep. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  9. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  10. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Hamacher, K [Columbia University Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

  11. Concordance between brain 18F-FDG PET and cerebrospinal fluid biomarkers in diagnosing Alzheimer's disease.

    Science.gov (United States)

    Rubí, S; Noguera, A; Tarongí, S; Oporto, M; García, A; Vico, H; Espino, A; Picado, M J; Mas, A; Peña, C; Amer, G

    Cortical posterior hypometabolism on PET imaging with 18 F-FDG (FDG-PET), and altered levels of Aß 1-42 peptide, total Tau (tTau) and phosphorylated Tau (pTau) proteins in cerebrospinal fluid (CSF) are established diagnostic biomarkers in Alzheimer's disease (AD). An evaluation has been made of the concordance and relationship between the results of FDG-PET and CSF biomarkers in symptomatic patients with suspected AD. A retrospective review was carried out on 120 patients with cognitive impairment referred to our Cognitive Neurology Unit, and who were evaluated by brain FDG-PET and a lumbar puncture for CSF biomarkers. In order to calculate their Kappa coefficient of concordance, the result of the FDG-PET and the set of the three CSF biomarkers in each patient was classified as normal, inconclusive, or AD-compatible. The relationship between the results of both methods was further assessed using logistic regression analysis, including the Aß 1-42 , tTau and pTau levels as quantitative predictors, and the FDG-PET result as the dependent variable. The weighted Kappa coefficient between FDG-PET and CSF biomarkers was 0.46 (95% CI: 0.35-0.57). Logistic regression analysis showed that the Aß 1-42 and tTau values together were capable of discriminating an FDG-PET result metabolically suggestive of AD from one non-suggestive of AD, with a 91% sensitivity and 93% specificity at the cut-off line Aß 1-42 =44+1.3×tTau. The level of concordance between FDG-PET and CSF biomarkers was moderate, indicating their complementary value in diagnosing AD. The Aß 1-42 and tTau levels in CSF help to predict the patient FDG-PET cortical metabolic status. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  12. [18F]FDOPA PET as an Endophenotype for Parkinson’s Disease Linkage Studies

    Science.gov (United States)

    Racette, Brad A.; Good, Laura; Antenor, Jo Ann; McGee-Minnich, Lori; Moerlein, Stephen M.; Videen, Tom O.; Perlmutter, Joel S.

    2008-01-01

    Parkinson Disease (PD) is a late onset disorder with age-dependent penetrance that may confound genetic studies since affected individuals may not demonstrate clinical manifestations at the time of evaluation. The use of endophenotypes, biologic surrogates for clinical disease diagnoses, may permit more accurate classification of at-risk subjects. Positron emission tomography (PET) measurements of 6-[18F]fluorodopa ([18F]FDOPA) uptake indicate nigrostriatal neuronal integrity and may provide a useful endophenotype for PD linkage studies. We performed [18F]FDOPA PET in 11 members of a large, multi-incident Amish family with PD, 24 normals and 48 people with clinically definite idiopathic PD (PD controls). Clinical diagnoses in the Amish were clinically definite PD in four, clinically probable in one, clinically possible in five, and normal in one. Abnormal [18F]FDOPA posterior putamen uptake was defined as less than three standard deviations below the normal mean. The criteria were applied to the Amish sample to determine a PET endophenotype for each. We performed genetic simulations using SLINK to model the effect phenoconversion with the PET endophenotype had on logarithm of odds (LOD) scores. PET endophenotype confirmed the status of two clinically definite subjects. Two clinically definite Amish PD subjects had normal PETs. Two possible PD were converted to “PET definite PD”. The remainder had normal PETs. The average maximum LOD score with the pre-PET was 6.14±0.84. Simulating phenoconversion of subjects with unknown phenotypes increased the LOD score to 7.36±1.23. The [18F]FDOPA PET endophenotype permits phenoconversion in multi-incident PD families and may increase LOD score accuracy and power of an informative pedigree. PMID:16528749

  13. Do allergic families avoid keeping furry pets?

    Science.gov (United States)

    Bertelsen, R J; Carlsen, K C L; Granum, B; Carlsen, K-H; Håland, G; Devulapalli, C S; Munthe-Kaas, M C; Mowinckel, P; Løvik, M

    2010-06-01

    Studies addressing the relationship between pet keeping and development of asthma and allergies may be influenced by pet avoidance in families with a history of allergic disease. Following a cohort of 1019 children in Oslo till 10 years of age, we studied the association of pet keeping with socio-economic factors and allergic disease in the family. A family history of asthma and rhinoconjunctivitis was not significantly associated with pet ownership at birth or with pet removal by 10 years. Acquiring cats and dogs was less likely if the child had allergic rhinoconjunctivitis, whereas no association was seen with asthma (in any family member). Single parenthood increased the likelihood of acquiring a cat, smoking parents more often had cats or dogs, and having older siblings was associated with keeping dogs and other furry pets. Among 319 families reporting pet avoidance, 70% never had pets, 8% had given up pets, and 22% avoided a particular type of pet only. Twenty-four per cent of the parents failed to retrospectively report pet keeping during the child's first year of life. Overall, allergic rhinitis, but not asthma was associated with actual pet avoidance, whereas the strongest predictors for keeping pets were found to be socio-economic factors. Allergic disease in a child most often does not lead to the removal of the family's furry pet. Pet avoidance is associated with allergic symptoms, but not asthma. Socio-economic factors like parental education, single parenthood and smoking affects the families' decisions on pet keeping, including the type of pets the families will avoid or acquire. The large recall error demonstrated points to the need for prospective data regarding pet keeping.

  14. Know the Risks of Feeding Raw Food to Your Pets

    Science.gov (United States)

    ... carefully consider the risks of feeding a raw pet food to their pets. Subscribe: FDA Consumer Health Information ... why. Knowing the Risk to Your Pet Raw pet food consists primarily of meat, bones, and organs that ...

  15. What do we measure in oncology PET?

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Kyoung June; Kim, Seong Jang [Dept. of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan (Korea, Republic of)

    2017-09-15

    Positron emission tomography (PET) has come to the practice of oncology. It is known that {sup 18}F-fluorodeoxyglucose (FDG) PET is more sensitive for the assessment of treatment response than conventional imaging. In addition, PET has an advantage in the use of quantitative analysis of the study. Nowadays, various PET parameters are adopted in clinical settings. In addition, a wide range of factors has been known to be associated with FDG uptake. Therefore, there has been a need for standardization and harmonization of protocols and PET parameters. We will introduce PET parameters and discuss major issues in this review.

  16. Clinical impact of FDG PET-CT on the management of patients with locally advanced cervical carcinoma

    International Nuclear Information System (INIS)

    Fleming, S.; Cooper, R.A.; Swift, S.E.; Thygesen, H.H.; Chowdhury, F.U.; Scarsbrook, A.F.; Patel, C.N.

    2014-01-01

    Aim: To evaluate the impact of staging FDG PET-CT on the initial management of patients with locally advanced cervical carcinoma (LACC) and any prognostic variables predicting survival. Materials and methods: Retrospective analysis of consecutive patients undergoing FDG PET-CT for staging of LACC in a single tertiary referral centre, between April 2008 and August 2011. Comparison was made between MRI and PET-CT findings and any subsequent impact on treatment intent or radiotherapy planning was evaluated. Results: Sixty-three patients underwent FDG PET-CT for initial staging of LACC. Major impact on management was found in 20 patients (32%), a minor impact in five (8%), and no impact in 38 (60%). In those patients where PET-CT had a major impact, 12 had more extensive local nodal involvement, five had occult metastatic disease, two had synchronous tumours, and one patient had equivocal lymph nodes on MRI characterized as negative. PET-positive nodal status at diagnosis was found to be a statistically significant predictor of relapse-free survival (p < 0.05). Conclusion: Staging FDG PET-CT has a major impact on the initial management of approximately one-third of patients with LACC by altering treatment intent and/or radiotherapy planning. PET-defined nodal status is a poor prognostic indicator. - Highlights: • Cervical carcinoma is one of the commonest cancers in women worldwide. • Locally advanced cervical carcinoma is usually treated with chemo-radiotherapy. • FDG PET-CT can have a major impact on management in up to one-third of patients. • It may alter treatment intent or radiotherapy-planning by detecting occult disease. • PET nodal status at diagnosis is an important predictor of relapse-free survival

  17. Impact of a 3-year pet management program on pet population and owner's perception.

    Science.gov (United States)

    Dias Costa, Esther; Martins, Camila Marinelli; Cunha, Graziela Ribeiro; Catapan, Dariane Cristina; Ferreira, Fernando; Oliveira, Simone Tostes; Garcia, Rita de Cassia Maria; Biondo, Alexander Welker

    2017-04-01

    Although pet population management programs have been established worldwide, few reports on program evaluation have been carried out to date. Accordingly, a 3-year longitudinal study has been carried out in a 4000 household neighborhood located within the metropolitan area of Curitiba, the eighth most populated city of Brazil. Visits were conducted and questionnaires completed to estimate and characterize the local pet population (animal sex, reproductive and vaccination status, street access). Care provided by owners, community perception on stray dog management and the possible changes were compared in these variables over time (2010 and 2013) were evaluated, after the establishment of a city pet population management program. In addition, associations between having children, owning dogs and cats, responsible pet ownership education and owner's perception on stray dogs were statistically tested. A total of 354/4000 (8.9%) household families were interviewed in 2010 and 70/354 (19.8%) of the same families again in 2013. No significant changes were found in overall number of dogs and cats and average pet age, animal care and owner's perception on stray dogs following the 3-year population management program. In 2010, an average of 1.6 dogs and 0.3 cats were found per family, with slightly more females (51.3% dogs and 51.1% cats), adults (4.0±3.5years for dogs and 2.1±2.4 for cats), intact (not neutered; 94.2% dogs and 84.0% cats) and lacking regular visit to veterinarian (71.6%). Although more families (53.1%) had children under 12 years old, no association was found between having children and having dogs and cats. Questionnaires revealed that owners perceived neutering/spaying to be the best pet population control method (42.4%), with "society" (50%) and "government" (49.4%) as responsible for pet population management. A significant positive association has been found between education level and the best way to control stray dogs (p=0.03), between having dogs

  18. Early and delayed prediction of axillary lymph node neoadjuvant response by {sup 18}F-FDG PET/CT in patients with locally advanced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Vicente, Ana Maria; Soriano Castrejon, Angel; Jimenez Londono, German Andres [University General Hospital, Nuclear Medicine Department, Ciudad Real (Spain); Leon Martin, Alberto [University General Hospital, Investigation Unit, Ciudad Real (Spain); Relea Calatayud, Fernanda [University General Hospital, Pathology Department, Ciudad Real (Spain); Munoz Sanchez, Maria del Mar [Virgen de la Luz Hospital, Oncology Department, Cuenca (Spain); Cruz Mora, Miguel Angel [Virgen de la Salud Hospital, Oncology Department, Toledo (Spain); Espinosa Aunion, Ruth [La Mancha Centro Hospital, Oncology Department, Ciudad Real (Spain)

    2014-07-15

    To determine the utility of {sup 18}F-FDG (FDG) PET/CT performed in an early and delayed phase during neoadjuvant chemotherapy in the prediction of lymph node histopathological response in patients with locally advanced breast cancer. FDG PET/CT studies performed in 76 patients (mean age 53 years) at baseline (PET-1), after the second course of chemotherapy (PET-2) and after the last course of chemotherapy (PET-3) were prospectively analysed. Inclusion criteria were lymph node involvement detected by PET/CT and non-sentinel node biopsy before or after the baseline PET/CT scan. Following the recommendations of the 12th International Breast Conference (St. Gallen), the patients were divided into five subgroups in relation to biological prognostic factors by immunohistochemistry. For diagnosis visual and semiquantitative analyses was performed. Absence of detectable lymph node uptake on the PET-2 or PET-3 scan with respect to the PET-1 scan was considered metabolic complete response (mCR). Lymph nodes were histopathologically classified according the lymph node regression grade and in response groups as pathological complete response (pCR) or not pCR (type A/D or B/C of the Smith grading system, respectively). ROC analysis was performed to determine a cut-off value of Δ% SUV1-2 and SUV1-3 for prediction of nodal status after chemotherapy. An association between mCR and pCR was found (Cohen's kappa analysis), and associations between phenotypes and metabolic behaviour and the final histopathological status were also found. Lymph node pCR was seen in 34 patients. The sensitivity, specificity, and positive and negative predictive values of PET-2 and PET-3 in establishing the final status of the axilla after chemotherapy were 52 %, 45 %, 50 % and 47 %, and 33 %, 84 %, 67 % and 56 %, respectively. No significant relationship was observed between mCR on PET-2 and PET-3 and pCR (p = 0.31 and 0.99, respectively). Lymph node metabolism on PET-1 was not able to predict

  19. Early and delayed prediction of axillary lymph node neoadjuvant response by 18F-FDG PET/CT in patients with locally advanced breast cancer

    International Nuclear Information System (INIS)

    Garcia Vicente, Ana Maria; Soriano Castrejon, Angel; Jimenez Londono, German Andres; Leon Martin, Alberto; Relea Calatayud, Fernanda; Munoz Sanchez, Maria del Mar; Cruz Mora, Miguel Angel; Espinosa Aunion, Ruth

    2014-01-01

    To determine the utility of 18 F-FDG (FDG) PET/CT performed in an early and delayed phase during neoadjuvant chemotherapy in the prediction of lymph node histopathological response in patients with locally advanced breast cancer. FDG PET/CT studies performed in 76 patients (mean age 53 years) at baseline (PET-1), after the second course of chemotherapy (PET-2) and after the last course of chemotherapy (PET-3) were prospectively analysed. Inclusion criteria were lymph node involvement detected by PET/CT and non-sentinel node biopsy before or after the baseline PET/CT scan. Following the recommendations of the 12th International Breast Conference (St. Gallen), the patients were divided into five subgroups in relation to biological prognostic factors by immunohistochemistry. For diagnosis visual and semiquantitative analyses was performed. Absence of detectable lymph node uptake on the PET-2 or PET-3 scan with respect to the PET-1 scan was considered metabolic complete response (mCR). Lymph nodes were histopathologically classified according the lymph node regression grade and in response groups as pathological complete response (pCR) or not pCR (type A/D or B/C of the Smith grading system, respectively). ROC analysis was performed to determine a cut-off value of Δ% SUV1-2 and SUV1-3 for prediction of nodal status after chemotherapy. An association between mCR and pCR was found (Cohen's kappa analysis), and associations between phenotypes and metabolic behaviour and the final histopathological status were also found. Lymph node pCR was seen in 34 patients. The sensitivity, specificity, and positive and negative predictive values of PET-2 and PET-3 in establishing the final status of the axilla after chemotherapy were 52 %, 45 %, 50 % and 47 %, and 33 %, 84 %, 67 % and 56 %, respectively. No significant relationship was observed between mCR on PET-2 and PET-3 and pCR (p = 0.31 and 0.99, respectively). Lymph node metabolism on PET-1 was not able to predict the final

  20. Parasites in pet reptiles

    Directory of Open Access Journals (Sweden)

    Mavri Urška

    2011-05-01

    Full Text Available Abstract Exotic reptiles originating from the wild can be carriers of many different pathogens and some of them can infect humans. Reptiles imported into Slovenia from 2000 to 2005, specimens of native species taken from the wild and captive bred species were investigated. A total of 949 reptiles (55 snakes, 331 lizards and 563 turtles, belonging to 68 different species, were examined for the presence of endoparasites and ectoparasites. Twelve different groups (Nematoda (5, Trematoda (1, Acanthocephala (1, Pentastomida (1 and Protozoa (4 of endoparasites were determined in 26 (47.3% of 55 examined snakes. In snakes two different species of ectoparasites were also found. Among the tested lizards eighteen different groups (Nematoda (8, Cestoda (1, Trematoda (1, Acanthocephala (1, Pentastomida (1 and Protozoa (6 of endoparasites in 252 (76.1% of 331 examined animals were found. One Trombiculid ectoparasite was determined. In 563 of examined turtles eight different groups (Nematoda (4, Cestoda (1, Trematoda (1 and Protozoa (2 of endoparasites were determined in 498 (88.5% animals. In examined turtles three different species of ectoparasites were seen. The established prevalence of various parasites in reptiles used as pet animals indicates the need for examination on specific pathogens prior to introduction to owners.

  1. Parasites in pet reptiles.

    Science.gov (United States)

    Rataj, Aleksandra Vergles; Lindtner-Knific, Renata; Vlahović, Ksenija; Mavri, Urška; Dovč, Alenka

    2011-05-30

    Exotic reptiles originating from the wild can be carriers of many different pathogens and some of them can infect humans. Reptiles imported into Slovenia from 2000 to 2005, specimens of native species taken from the wild and captive bred species were investigated. A total of 949 reptiles (55 snakes, 331 lizards and 563 turtles), belonging to 68 different species, were examined for the presence of endoparasites and ectoparasites. Twelve different groups (Nematoda (5), Trematoda (1), Acanthocephala (1), Pentastomida (1) and Protozoa (4)) of endoparasites were determined in 26 (47.3%) of 55 examined snakes. In snakes two different species of ectoparasites were also found. Among the tested lizards eighteen different groups (Nematoda (8), Cestoda (1), Trematoda (1), Acanthocephala (1), Pentastomida (1) and Protozoa (6)) of endoparasites in 252 (76.1%) of 331 examined animals were found. One Trombiculid ectoparasite was determined. In 563 of examined turtles eight different groups (Nematoda (4), Cestoda (1), Trematoda (1) and Protozoa (2)) of endoparasites were determined in 498 (88.5%) animals. In examined turtles three different species of ectoparasites were seen. The established prevalence of various parasites in reptiles used as pet animals indicates the need for examination on specific pathogens prior to introduction to owners.

  2. Beneficial effects of pet ownership on some aspects of human health and behaviour.

    Science.gov (United States)

    Serpell, J

    1991-12-01

    A 10-month prospective study was carried out which examined changes in behaviour and health status in 71 adult subjects following the acquisition of a new pet (either dogs or cats). A group of 26 subjects without pets served as a comparison over the same period. Both pet-owning groups reported a highly significant reduction in minor health problems during the first month following pet acquisition, and this effect was sustained in dog owners through to 10 months. The pet-acquiring groups also showed improvements in their scores on the 30-item General Health Questionnaire over the first 6 months and, in dog owners, this improvement was maintained until 10 months. In addition, dog owners took considerably more physical exercise while walking their dogs than the other two groups, and this effect continued throughout the period of study. The group without pets exhibited no statistically significant changes in health or behaviour, apart from a small increase in recreational walking. The results provide evidence that pet acquisition may have positive effects on human health and behaviour, and that in some cases these effects are relatively long term.

  3. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  4. Clinical evidence on PET-CT for radiation therapy planning in cervix and endometrial cancers

    International Nuclear Information System (INIS)

    Haie-Meder, Christine; Mazeron, Renaud; Magne, Nicolas

    2010-01-01

    PET-CT plays an increasing role in the diagnosis and treatment of gynaecological cancers. In cervix cancer, whilst MRI remains the best imaging technique for initial primary tumor staging, PET-CT has been showed to be a highly sensitive method to determine lymph node status, except in patients with early-stage cervical cancer where PET-CT cannot replace surgical exploration of pelvic lymph nodes. In patients with advanced cervical cancer, PET-CT has the potential of showing lymph node metastasis not only within the pelvis, but also outside the pelvis, more particularly in the para-aortic area. PET-CT has also been described as a useful tool in 3-D-based adaptative brachytherapy. In endometrial cancer, the issues are different, as the recent decade has seen a therapeutic decrease in early-stage disease, especially in postoperative radiation therapy, whilst more advanced disease have been approached with more aggressive treatments, integrating chemotherapy and external beam radiotherapy. Lymph node status is also an important issue and PET-Scan may replace lymph node surgical procedure particularly in obese patients.

  5. The system of the designing for PET detectors

    International Nuclear Information System (INIS)

    Fang Zongliang

    2006-01-01

    PET stands for Positron Emission Tomography, a new nuclear medicine imaging device. PET detector is the key of PET. This paper introduces a system of the designing for PET detector. The system can be used to design various PET detector. A PET detector BLOCK with 8 x 8 crystals has been designed and built by this system. (authors)

  6. Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers

    International Nuclear Information System (INIS)

    Chung, Ji In; Choi, Joon Young; Lee, Kyung Han; Kim, Byung Tae; Choi, Yoon Ho; Cho, Han Byoul; Shim, Jae Yong

    2009-01-01

    We retrospectively investigated the diagnostic performance of 18 F-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening

  7. PET and PET/CT in oncology: the key of diagnostic challenge

    International Nuclear Information System (INIS)

    Mortelmans, L.; Stroobants, S.; Spaepen, K.

    2004-01-01

    In this presentation authors present use of positron emission tomography (PET) in oncology. This lecture is divided to the following parts: (1) Assessment of treatment response; (2) Treatment monitoring by PET: clinical examples; (3) PET for early response assessment; (4) Use of PET in Radiotherapy planning

  8. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT

    DEFF Research Database (Denmark)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani

    2016-01-01

    UNLABELLED: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimize...

  9. PET imaging in breast cancer

    International Nuclear Information System (INIS)

    Bombardieri, E.; Crippa, F.

    2001-01-01

    The basis of tumour imaging with PET is a specific uptake mechanism of positron emitting radiopharmaceuticals. Among the potential tracers for breast cancer (fluorodeoxyglucose, methionine, tyrosine, fluoro-estradiol, nor-progesterone), 2-deoxy-2-fluoro-D-glucose labelled with fluorine (FDG) is the most widely used radiopharmaceutical because breast cancer is particularly avid of FDG and 18 F has the advantages of the a relatively long physical half-life. Mammography is the first choice examination in studying breast masses, due to its very good performances, an excellent compliance and the best value regarding the cost/effectiveness aspects. The FDG uptake in tissue correlates with the histological grade and potential aggressiveness of breast cancer and this may have prognostic consequences. Besides the evaluation of breast lesions, FDG-PET shows a great efficacy in staging lymph node involvement prior surgery and this could have a great value in loco-regional staging. Whole body PET provides also information with regard to metastasis localizations both in soft tissue and bone, and plays an important clinical role mainly in detecting recurrent metastatic disease. In fact for its metabolic characteristics PET visualizes regions of enhanced metabolic activity and can complete other imaging modalities based on structural anatomic changes. Even though CT and MRI show superior resolution characteristics, it has been demonstrated that PET provides more accurate information in discriminating between viable tumour, fibrotic scar or necrosis. These statements are coming from the examination of more than 2000 breast cancer detection

  10. PET/MRI in cancer patients

    DEFF Research Database (Denmark)

    Kjær, Andreas; Loft, Annika; Law, Ian

    2013-01-01

    Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear...... Medicine & PET at Rigshospitalet in Copenhagen we installed an integrated PET/MRI in December 2011. Here, we describe our first clinical PET/MR cases and discuss some of the areas within oncology where we envision promising future application of integrated PET/MR imaging in clinical routine. Cases...... described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision...

  11. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    Science.gov (United States)

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Validating PET segmentation of thoracic lesions-is 4D PET necessary?

    DEFF Research Database (Denmark)

    Nielsen, M. S.; Carl, J.

    2017-01-01

    Respiratory-induced motions are prone to degrade the positron emission tomography (PET) signal with the consequent loss of image information and unreliable segmentations. This phantom study aims to assess the discrepancies relative to stationary PET segmentations, of widely used semiautomatic PET...... segmented using three SUV threshold methods (Max40%, SUV40% and 2.5SUV) and a gradient based method (GradientSeg). Segmentations in static 3D-PET scans (PETsta) specified the reference conditions for the individual segmentation methods, target lesions and tracer concentrations. The motion included PET...... images followed a 4D-PET (PET4D) and a 3D-PET (PETmot) scan protocol. Moreover, motion-corrected PET images (PETdeb) were derived from the PETmot images. Segmentations in PET4D, PETmot and PETdeb were compared to the PETsta segmentations according to volume changes (Delta Vol) and an error estimate (low...

  13. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  14. Latest achievements in PET techniques

    Science.gov (United States)

    Del Guerra, Alberto; Belcari, Nicola; Motta, Alfonso; Di Domenico, Giovanni; Sabba, Nicola; Zavattini, Guido

    2003-11-01

    Positron emission tomography (PET) has moved from a distinguished research tool in physiology, cardiology and neurology to become a major tool for clinical investigation in oncology, in cardiac applications and in neurological disorders. Much of the PET accomplishments is due to the remarkable improvements in the last 10 years both in hardware and software aspects. Nowadays a similar effort is made by many research groups towards the construction of dedicated PET apparatus in new emerging fields such as molecular medicine, gene therapy, breast cancer imaging and combined modalities. This paper reports on some recent results we have obtained in small animal imaging and positron emission mammography, based on the use of advanced technology in the field of scintillators and photodetectors, such as Position-Sensitive Detectors coupled to crystal matrices, combined use of scintillating fibers and Hybrid-Photo-Diodes readout, and Hamamatsu flat panels. New ideas and future developments are discussed.

  15. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  16. PET Metabolic Biomarkers for Cancer

    Directory of Open Access Journals (Sweden)

    Etienne Croteau

    2016-01-01

    Full Text Available The body's main fuel sources are fats, carbohydrates (glucose, proteins, and ketone bodies. It is well known that an important hallmark of cancer cells is the overconsumption of glucose. Positron emission tomography (PET imaging using the glucose analog 18 F-fluorodeoxyglucose ( 18 F-FDG has been a powerful cancer diagnostic tool for many decades. Apart from surgery, chemotherapy and radiotherapy represent the two main domains for cancer therapy, targeting tumor proliferation, cell division, and DNA replication–-all processes that require a large amount of energy. Currently, in vivo clinical imaging of metabolism is performed almost exclusively using PET radiotracers that assess oxygen consumption and mechanisms of energy substrate consumption. This paper reviews the utility of PET imaging biomarkers for the detection of cancer proliferation, vascularization, metabolism, treatment response, and follow-up after radiation therapy, chemotherapy, and chemotherapy-related side effects.

  17. Multiparametric PET/CT-perfusion does not add significant additional information for initial staging in lung cancer compared with standard PET/CT

    Science.gov (United States)

    2014-01-01

    Background The purpose of this study was to assess the relationship of CT-perfusion (CTP), 18F-FDG-PET/CT and histological parameters, and the possible added value of CTP to FDG-PET/CT in the initial staging of lung cancer. Methods Fifty-four consecutive patients (median age 65 years, 15 females, 39 males) with suspected lung cancer were evaluated prospectively by CT-perfusion scan and 18F-FDG-PET/CT scan. Overall, 46 tumors were identified. CTP parameters blood flow (BF), blood volume (BV), and mean transit time (MTT) of the tumor tissue were calculated. Intratumoral microvessel density (MVD) was assessed quantitatively. Differences in CTP parameters concerning tumor type, location, PET positivity of lymph nodes, TNM status, and UICC stage were analyzed. Spearman correlation analyses between CTP and 18F-FDG-PET/CT parameters (SUVmax, SUVmean, PETvol, and TLG), MVD, tumor size, and tumor stage were performed. Results The mean BF (mL/100 mL min-1), BV (mL/100 mL), and MTT (s) was 35.5, 8.4, and 14.2, respectively. The BF and BV were lower in tumors with PET-positive lymph nodes (p = 0.02). However, the CTP values were not significantly different among the N stages. The CTP values were not different, depending on tumor size and location. No significant correlation was found between CTP parameters and MVD. Conclusions Overall, the CTP information showed only little additional information for the initial staging compared with standard FDG-PET/CT. Low perfusion in lung tumors might possibly be associated with metabolically active regional lymph nodes. Apart from that, both CTP and 18F-FDG-PET/CT parameter sets may reflect different pathophysiological mechanisms in lung cancer. PMID:24450990

  18. 36 CFR 13.1106 - Pets.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Pets. 13.1106 Section 13.1106 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK... Provisions § 13.1106 Pets. Pets are prohibited except— (a) On the Bartlett Cove Public Use Dock; (b) On the...

  19. 7 CFR 503.11 - Pets.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Pets. 503.11 Section 503.11 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON PLUM ISLAND ANIMAL DISEASE CENTER § 503.11 Pets. No pets or animals of any kind may be brought...

  20. 36 CFR 13.1234 - Pets.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Pets. 13.1234 Section 13.1234 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK... § 13.1234 Pets. Possessing a pet in the BCDA is prohibited. ...

  1. 7 CFR 500.10 - Pets.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Pets. 500.10 Section 500.10 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE NATIONAL ARBORETUM Conduct on U.S. National Arboreturm Property § 500.10 Pets. Pets brought upon USNA...

  2. 36 CFR 13.978 - Pets.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Pets. 13.978 Section 13.978 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK... (fda) § 13.978 Pets. Possessing a pet is prohibited— (a) In the FDA, except in public parking areas, on...

  3. 36 CFR 13.1310 - Pets.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Pets. 13.1310 Section 13.1310... SYSTEM UNITS IN ALASKA Special Regulations-Kenai Fjords National Park General Provisions § 13.1310 Pets. (a) Pets are prohibited— (1) In the Exit Glacier Developed Area except in the parking lot, on the...

  4. Pet therapy: dogs de-stress students.

    Science.gov (United States)

    Young, Judith S

    2012-01-01

    Research supports the efficacy of the human-animal bond and pet therapy in a variety of settings. At nursing students' request at one school, the author began offering pet therapy prior to examinations. Anecdotal evidence of a study with the author's Golden Retriever, Goldilocks, demonstrates that pet therapy can reduce test anxiety and improve nursing student performance.

  5. Clinical PET/MR Imaging in Oncology

    DEFF Research Database (Denmark)

    Kjær, Andreas; Torigian, Drew A.

    2016-01-01

    . The question, therefore, arises regarding what the future clinical applications of PET/MR imaging will be. In this article, the authors discuss ways in which PET/MR imaging may be used in future applications that justify the added cost, predominantly focusing on oncologic applications. The authors suggest...... that such areas include combined molecular and functional imaging, multimodality radiomics, and hyperPET....

  6. THE CHARACTERISTICS OF EEC PET INSTRUMENTATION

    NARCIS (Netherlands)

    PAANS, AMJ

    1991-01-01

    As a result of a Guide-Questionnaire distributed among all European PET centers an inventory of the European PET instrumentation has become available in a data base. An overview and analysis of the European PET equipment, cyclotrons, scanners and software, together with some global information on

  7. PET-scanninger af hjernen

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Aanerud, Joel Fredrik Astrup

    2017-01-01

    PET-skanninger bruges i stigende grad til at diagnosticere hjernetumorer og neurodegenerative lidelser hos mennesker. Nogle af disse metoder vil potentelt også kunne finde veterinær anvendelse i de kommende år til diagnostik af hjernelidelser hos hos kæledyr.......PET-skanninger bruges i stigende grad til at diagnosticere hjernetumorer og neurodegenerative lidelser hos mennesker. Nogle af disse metoder vil potentelt også kunne finde veterinær anvendelse i de kommende år til diagnostik af hjernelidelser hos hos kæledyr....

  8. PET and PET/CT in malignant melanoma

    International Nuclear Information System (INIS)

    Garcia O, J.R.

    2007-01-01

    The advantages that it has the PET/CT are: 1. It diminishes mainly positive false lesions. It identifies physiologic accumulate places. 2. It diminishes in smaller grade false negative. Small injuries. Injuries with low grade concentration. Injure on intense activity areas. 3. Precise anatomical localization of accumulate places. 4. Reduction of the acquisition time. (Author)

  9. Competitive advantage of PET/MRI.

    Science.gov (United States)

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Epilepsy and PET

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Ishijima, Buichi

    1984-01-01

    The glucose metabolism of interictal epileptic foci in human brains were analyzed by positron emission tomography. The seizure patterns of 29 epileptic patients were as follows; complex partial 13 cases, elementary partial 9 cases, and generalized 7 cases. 11 C was produced by a JSW medical cyclotron BC105 and was randomly tagged to glucose prepared by photosynthesis. Data sampling by PET was started 15 minutes after peroral administration of 11 C-glucose to the patients. Three slices with 1.75 cm distance were obtained by a single scanning. In temporal lobe epilepsy, three slices were selected as 2.0 cm, 3.75 cm and 5.5 cm above orbitomeatal line. The basal ganglia were scanned 4.5 -- 5.0 cm and the motor and sensory strips were 5.0 -- 9.0 cm above OML. The glucose metabolic rate was expressed with color scales and qualitatively estimated. The results disclosed an obvious hypometabolic zone around a focus area in 22 cases (76%) out of the 29 subjects. This hypometabolic zone was observed in 12 cases (92%) of 13 complex partial, 9 cases (78%) of 9 elementary partial, and 3 cases (43%) of 7 generalized seizure patterns. In temporal lobe epilepsy, the location of the hypometabolic zone was different according to the clinical symptoms. The patients with automatism, pseudoabsence, autonomic, and emotional symptoms had its foci in the mesial portion of the temporal lobe. On the other hand, the patients with psychical seizure revealed its low metabolic area in the lateral temporal cortex. In the elementary partial epilepsy, the hypoactive zones were observed in the motor, sensory, and visual cortical area in accordance with the clinical symptoms. Very interestingly, an explicit cortical focus was discovered in two cases of the generalized epilepsy. In these cases the mechanism of secondary generalization was supposed to proceed in the expression of their clinical symptoms. In one Lennox-Gastaut case, a unilateral temporal lobe was involved as the seizure focus. (J.P.N.)

  11. Palliative care and compound in household pets.

    Science.gov (United States)

    Gaskins, Jessica L

    2012-01-01

    Palliative care is not a term solely used for humans when discussing health care; the term is also used when discussing veterinary patients. Pets are considered part of the family by pet owners, and they have a special relationship that only another pet owner can fully understand. This article discusses some of the healthcare problems that affect pets (and their owners), statistics on the most commonly used medications for veterinary patients, quality of life, and discussions on the veterinary pharmacist-owner-palliative pet relationship and how compounding pharmacists can prepare patient-specific medications.

  12. Kinetic modeling in PET imaging of hypoxia

    DEFF Research Database (Denmark)

    Li, Fan; Jørgensen, Jesper Tranekjær; Hansen, Anders E

    2014-01-01

    Tumor hypoxia is associated with increased therapeutic resistance leading to poor treatment outcome. Therefore the ability to detect and quantify intratumoral oxygenation could play an important role in future individual personalized treatment strategies. Positron Emission Tomography (PET) can...... be used for non-invasive mapping of tissue oxygenation in vivo and several hypoxia specific PET tracers have been developed. Evaluation of PET data in the clinic is commonly based on visual assessment together with semiquantitative measurements e.g. standard uptake value (SUV). However, dynamic PET...... analysis for PET imaging of hypoxia....

  13. The MiniPET: a didactic PET system

    Science.gov (United States)

    Pedro, R.; Silva, J.; Gurriana, L.; Silva, J. M.; Maio, A.; Soares Augusto, J.

    2013-03-01

    The MiniPET project aims to design and build a small PET system. It consists of two 4 × 4 matrices of 16 LYSO scintillator crystals and two PMTs with 16 channels resulting in a low cost system with the essential functionality of a clinical PET instrument. It is designed to illustrate the physics of the PET technique and to provide a didactic platform for the training of students and nuclear imaging professionals as well as for scientific outreach. The PET modules can be configured to test for the coincidence of 511 keV gamma rays. The model has a flexible mechanical setup [1] and can simulate 14 diferent ring geometries, from a configuration with as few as 18 detectors per ring (ring radius phi=51 mm), up to a geometry with 70 detectors per ring (phi=200 mm). A second version of the electronic system [2] allowed measurement and recording of the energy deposited in 4 detector channels by photons from a 137Cs radioactive source and by photons resulting of the annihilation of positrons from a 22Na radioactive source. These energy spectra are used for detector performance studies, as well as angular dependency studies. In this paper, the mechanical setup, the front-end high-speed analog electronics, the digital acquisition and control electronics implemented in a FPGA, as well as the data-transfer interface between the FPGA board and a host PC are described. Recent preliminary results obtained with the 4 active channels in the prototype are also presented.

  14. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-01-01

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  15. {sup 18}F-FDG PET/CT for initial staging in breast cancer patients. Is there a relevant impact on treatment planning compared to conventional staging modalities?

    Energy Technology Data Exchange (ETDEWEB)

    Krammer, J.; Schnitzer, A.; Kaiser, C.G.; Buesing, K.A.; Schoenberg, S.O.; Wasser, K. [University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Sperk, E. [University of Heidelberg, Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Brade, J. [University of Heidelberg, Institute of Medical Statistics, Biomathematics and Data Processing, Medical Faculty Mannheim, Mannheim (Germany); Wasgindt, S.; Suetterlin, M. [University of Heidelberg, Department of Gynaecology and Obstetrics, University Medical Centre Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Sutton, E.J. [Memorial Sloan-Kettering Cancer Center, Evelyn H. Lauder Breast Center, Department of Radiology, New York, NY (United States)

    2015-08-15

    To evaluate the impact of whole-body {sup 18}F-FDG PET/CT on initial staging of breast cancer in comparison to conventional staging modalities. This study included 102 breast cancer patients, 101 patients were eligible for evaluation. Preoperative whole-body staging with PET/CT was performed in patients with clinical stage ≥ T2 tumours or positive local lymph nodes (n = 91). Postoperative PET/CT was performed in patients without these criteria but positive sentinel lymph node biopsy (n = 10). All patients underwent PET/CT and a conventional staging algorithm, which included bone scan, chest X-ray and abdominal ultrasound. PET/CT findings were compared to conventional staging and the impact on therapeutic management was evaluated. PET/CT led to an upgrade of the N or M stage in overall 19 patients (19 %) and newly identified manifestation of breast cancer in two patients (2 %). PET/CT findings caused a change in treatment of 11 patients (11 %). This is within the range of recent studies, all applying conventional inclusion criteria based on the initial T and N status. PET/CT has a relevant impact on initial staging and treatment of breast cancer when compared to conventional modalities. Further studies should assess inclusion criteria beyond the conventional T and N status, e.g. tumour grading and receptor status. (orig.)

  16. Understanding the context for pet cat and dog feeding and exercising behaviour among pet owners in Ireland: a qualitative study.

    Science.gov (United States)

    Downes, Martin J; Devitt, Catherine; Downes, Marie T; More, Simon J

    2017-01-01

    Pet cat and dog obesity contributes to increased risk of several diseases, including cancer and diabetes mellitus as well as a worsening of orthopaedic problems, and a reduction in survival rate. This study aims to develop a better understanding of cat and dog owners' self-reported beliefs and factors that influence owner behaviour around feeding and exercising their pet cat or dog, as there is a lack of in-depth understanding in this area. Seven focus group discussions, with 43 pet owners in total, were conducted. Pet owners often reported a perceived a low level of control over feeding; often undermined by other people feeding of their pet, their pets begging for food, and their pets attitude towards food. Treats were used in the absence of owner control over pet begging and emotional attachment, and to influence pet behaviour. The majority of participants had positive attitudes to pet exercise, which could be related to pet specific requirements, especially differences in cats and dogs. There were some negative experiences of stress associated with dog walking and fears over aggressive confrontations with other dogs. Feeding one's pet is influenced by beliefs about pet specific needs, pet food and pet health, pet owners' perceived control over feeding, and the implications for the pet owner. Pet exercise is influenced by beliefs about pet specific exercise needs, and the implications of exercising one's pet for the pet owner. Understanding owner behaviours on feeding and exercise allows for a more targeted approach to preventing and treating pet obesity.

  17. Diseases Transmitted by Less Common House Pets.

    Science.gov (United States)

    Chomel, Bruno B

    2015-12-01

    Beside dogs and cats, the most common pets worldwide, an increasing number of pocket pets and exotic pets are making their way to more and more households, especially in North America and Europe. Although many of these animals make appropriate pets, they also can be a source of many zoonotic diseases, especially in young children and immunocompromised individuals. Some of these diseases can be life threatening, such as rabies, rat bite fever, and plague. Some others are quite common, because of the frequency of the pathogens harbored by these species, such as salmonellosis in reptiles and amphibians. Appropriate knowledge of the zoonotic agents carried by these "new" pet species is strongly recommended prior to acquiring pocket or exotic pets. Furthermore, adopting wildlife as pets is strongly discouraged, because it is always a risky action that can lead to major health issues.

  18. Quantitative simultaneous PET-MR imaging

    Science.gov (United States)

    Ouyang, Jinsong; Petibon, Yoann; Huang, Chuan; Reese, Timothy G.; Kolnick, Aleksandra L.; El Fakhri, Georges

    2014-06-01

    Whole-body PET is currently limited by the degradation due to patient motion. Respiratory motion degrades imaging studies of the abdomen. Similarly, both respiratory and cardiac motions significantly hamper the assessment of myocardial ischemia and/or metabolism in perfusion and viability cardiac PET studies. Based on simultaneous PET-MR, we have developed robust and accurate MRI methods allowing the tracking and measurement of both respiratory and cardiac motions during abdominal or cardiac studies. Our list-mode iterative PET reconstruction framework incorporates the measured motion fields into PET emission system matrix as well as the time-dependent PET attenuation map and the position dependent point spread function. Our method significantly enhances the PET image quality as compared to conventional methods.

  19. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  20. Innovations in PET/CT

    DEFF Research Database (Denmark)

    Levin Klausen, T; Høgild Keller, S; Vinter Olesen, O

    2012-01-01

    especially as spatial resolution improves. Software based image fusion remains a complex issue outside the brain. State of the art image quality in a modern PET/CT system includes incorporation of point spread function (PSF) and time-of-flight (TOF) information into the reconstruction leading to the high...

  1. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  2. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O.B.; Lassen, N.A.

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...

  3. Particle Accelerators for PET radionuclides

    DEFF Research Database (Denmark)

    Jensen, Mikael

    2012-01-01

    The requirements set for particle accelerators for production of radioactive isotopes for PET can easily be derived from first principles. The simple general need is for proton beams with energy in the region 10–20 MeV and current 20–100 microAmps. This is most reliably and cost-effectively achie......The requirements set for particle accelerators for production of radioactive isotopes for PET can easily be derived from first principles. The simple general need is for proton beams with energy in the region 10–20 MeV and current 20–100 microAmps. This is most reliably and cost...... different manufacturers will be discussed the light of what is actually needed for a given PET site operation. Alternatives to the conventional cyclotron have been proposed and tested but have at present very limited use. These alternatives will be discussed, as well as the future possibilities of supplying...... point of demand tracer production with very small cyclotrons of energy well below 10 MeV. The authors best advice at present for new PET sites is to negotiate for conventional cyclotron solutions from experienced manufacturers. It is the combined performance of cyclotron and target in terms of available...

  4. Diagnostic imaging of exotic pets

    International Nuclear Information System (INIS)

    Silverman, S.

    1993-01-01

    Radiographic, ultrasonographic, and computed tomographic (CT) imaging are important diagnostic modalities in exotic pets. The use of appropriate radiographic equipment, film-screen combinations, and radiographic projections enhances the information obtained from radiographs. Both normal findings and common radiographic abnormalities are discussed. The use of ultrasonography and CT scanning for exotic small mammals and reptiles is described

  5. PET-guided breast biopsy.

    Science.gov (United States)

    Kalinyak, Judith E; Schilling, Kathy; Berg, Wendie A; Narayanan, Deepa; Mayberry, Jennifer P; Rai, Rajesh; Dupree, Elizabeth B; Shusterman, Denise K; Gittleman, Mark A; Luo, Weidong; Matthews, Chris G

    2011-01-01

    Molecular imaging, using positron emission tomography (PET), has become an integral step in the evaluation of many patients with malignancy. However, its use in patients with breast cancer has been limited by the lower levels of (18) F-fluorodeoxyglucose (FDG) uptake in some breast malignancies compared to other cancers, the small size of many breast cancers, and the need for biopsy under PET guidance. High-resolution breast PET, or positron emission mammography (PEM), with biopsy guidance software, now addresses these issues. We report a prospective, multicenter study designed to test the efficacy and safety of PEM biopsy guidance software in women with FDG-avid breast lesions worrisome for malignancy. The intervention chosen was vacuum-assisted core biopsy. Nineteen subjects underwent a total of 24 PEM-guided biopsies. All lesions were successfully targeted and sampled as determined by post-biopsy image scan evaluation, specimen imaging, and pathologic concordance. Invasive cancer was identified in 13 of 24 lesions (54%), while four (17%) were high-risk lesions and three of these were upgraded to malignancy at excision. No serious adverse events occurred and all patients found the procedure to cause only minimal to mild discomfort. High-resolution PEM-guided breast biopsy is both safe and effective for the sampling of PET-depicted breast lesions. © 2011 Wiley Periodicals, Inc.

  6. Recommendations for the use of PET and PET-CT for radiotherapy planning in research projects.

    Science.gov (United States)

    Somer, E J; Pike, L C; Marsden, P K

    2012-08-01

    With the increasing use of positron emission tomography (PET) for disease staging, follow-up and therapy monitoring in a number of oncological indications there is growing interest in the use of PET and PET-CT for radiation treatment planning. In order to create a strong clinical evidence base for this, it is important to ensure that research data are clinically relevant and of a high quality. Therefore the National Cancer Research Institute PET Research Network make these recommendations to assist investigators in the development of radiotherapy clinical trials involving the use of PET and PET-CT. These recommendations provide an overview of the current literature in this rapidly evolving field, including standards for PET in clinical trials, disease staging, volume delineation, intensity modulated radiotherapy and PET-augmented planning techniques, and are targeted at a general audience. We conclude with specific recommendations for the use of PET in radiotherapy planning in research projects.

  7. Brain fluorodeoxyglucose PET in adrenoleukodystrophy.

    Science.gov (United States)

    Salsano, Ettore; Marotta, Giorgio; Manfredi, Valentina; Giovagnoli, Anna Rita; Farina, Laura; Savoiardo, Mario; Pareyson, Davide; Benti, Riccardo; Uziel, Graziella

    2014-09-09

    To investigate the cerebral glucose metabolism in subjects with X-linked adrenoleukodystrophy (X-ALD) by using brain [(18)F]-fluorodeoxyglucose PET (FDG-PET). Cross-sectional study in which 12 adults with various forms of X-ALD underwent clinical evaluation and brain MRI, followed by brain FDG-PET, neuropsychological assessment, and personality and psychopathology evaluation using the Symptom Checkist-90-Revised (SCL-90-R) and the Millon Clinical Multiaxial Inventory-III (MCMI-III). When compared to healthy control subjects (n = 27) by using Statistical Parametric Mapping 8 software, the patients with X-ALD-with or without brain MRI changes-showed a pattern of increased glucose metabolism in frontal lobes and reduced glucose metabolism in cerebellum and temporal lobe areas. On single case analysis by Scenium software, we found a similar pattern, with significant (p < 0.02) correlation between the degree of hypermetabolism in the frontal lobes of each patient and the corresponding X-ALD clinical scores. With respect to personality, we found that patients with X-ALD usually present with an obsessive-compulsive personality disorder on the MCMI-III, with significant (p < 0.05) correlation between glucose uptake in ventral striatum and severity of score on the obsessive-compulsive subscale. We examined cerebral glucose metabolism using FDG-PET in a cohort of patients with X-ALD and provided definite evidence that in X-ALD the analysis of brain glucose metabolism reveals abnormalities independent from morphologic and signal changes detected by MRI and related to clinical severity. Brain FDG-PET may be a useful neuroimaging technique for the characterization of X-ALD and possibly other leukodystrophies. © 2014 American Academy of Neurology.

  8. Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT

    International Nuclear Information System (INIS)

    Wetter, Axel; Lipponer, Christine; Nensa, Felix; Altenbernd, Jens-Christian; Schlosser, Thomas; Lauenstein, Thomas; Heusch, Philipp; Ruebben, Herbert; Bockisch, Andreas; Poeppel, Thorsten; Nagarajah, James

    2014-01-01

    The aim of this study was to evaluate the positron emission tomography (PET) component of [ 18 F]choline PET/MRI and compare it with the PET component of [ 18 F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer. Thirty-six patients were examined with simultaneous [ 18 F]choline PET/MRI following combined [ 18 F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUV max and SUV mean ) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUV max and SUV mean was tested using Pearson's product-moment correlation and Bland-Altman analysis. All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUV max and SUV mean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p max of PET/CT and PET/MRI (R = 0.86, p mean of PET/CT and PET/MRI (R = 0.81, p max of PET/CT vs PET/MRI and -1.12 to +2.23 between SUV mean of PET/CT vs PET/MRI. PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUV max and SUV mean was found. Both SUV max and SUV mean were significantly lower in [ 18 F]choline PET/MRI than in [ 18 F]choline PET/CT. Differences of SUV max and SUV mean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [ 18 F]choline between the subsequent examinations and in the respective organ systems have to be taken into account. (orig.)

  9. Survival outcomes in patients with cervical cancer after inclusion of PET/CT in staging procedures

    DEFF Research Database (Denmark)

    Hansen, Henrik Villibald; Loft, Annika; Berthelsen, Anne Kiil

    2015-01-01

    , performance status, BMI, and histopathology. CONCLUSION: Inclusion of PET/CT in the preradiotherapy diagnostic protocol may lead to nodal stage migration not reflected in the FIGO stage. It was found to be a significant covariate, and could lead to selection bias that needs to be taken into account when...... designing and reporting on clinical trials....

  10. {sup 68}Ga-PSMA-HBED-CC PET imaging in breast carcinoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sathekge, Mike; Lengana, Thabo; Modiselle, Moshe; Vorster, Mariza; Zeevaart, JanRijn; Ebenhan, Thomas [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); Maes, Alex [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2017-04-15

    To report on imaging findings using {sup 68}Ga-PSMA-HBED-CC PET in a series of 19 breast carcinoma patients. {sup 68}Ga-PSMA-HBED-CC PET imaging results obtained were compared to routinely performed staging examinations and analyzed as to lesion location and progesterone receptor status. Out of 81 tumor lesions identified, 84% were identified on {sup 68}Ga-PSMA-HBED-CC PET. {sup 68}Ga-PSMA-HBED-CC SUVmean values of distant metastases proved significantly higher (mean, 6.86, SD, 5.68) when compared to those of primary or local recurrences (mean, 2.45, SD, 2.55, p = 0.04) or involved lymph nodes (mean, 3.18, SD, 1.79, p = 0.011). SUVmean values of progesterone receptor-positive lesions proved not significantly different from progesterone receptor-negative lesions. SUV values derived from FDG PET/CT, available in seven patients, and {sup 68}Ga-PSMA-HBED-CC PET/CT imaging proved weakly correlated (r = 0.407, p = 0.015). {sup 68}Ga-PSMA-HBED-CC PET/CT imaging in breast carcinoma confirms the reported considerable variation of PSMA expression on human solid tumors using immunohistochemistry. (orig.)

  11. Exposure to household furry pets influences the gut microbiota of infant at 3-4 months following various birth scenarios.

    Science.gov (United States)

    Tun, Hein M; Konya, Theodore; Takaro, Tim K; Brook, Jeffrey R; Chari, Radha; Field, Catherine J; Guttman, David S; Becker, Allan B; Mandhane, Piush J; Turvey, Stuart E; Subbarao, Padmaja; Sears, Malcolm R; Scott, James A; Kozyrskyj, Anita L

    2017-04-06

    Early-life exposure to household pets has the capacity to reduce risk for overweight and allergic disease, especially following caesarean delivery. Since there is some evidence that pets also alter the gut microbial composition of infants, changes to the gut microbiome are putative pathways by which pet exposure can reduce these risks to health. To investigate the impact of pre- and postnatal pet exposure on infant gut microbiota following various birth scenarios, this study employed a large subsample of 746 infants from the Canadian Healthy Infant Longitudinal Development Study (CHILD) cohort, whose mothers were enrolled during pregnancy between 2009 and 2012. Participating mothers were asked to report on household pet ownership at recruitment during the second or third trimester and 3 months postpartum. Infant gut microbiota were profiled with 16S rRNA sequencing from faecal samples collected at the mean age of 3.3 months. Two categories of pet exposure (i) only during pregnancy and (ii) pre- and postnatally were compared to no pet exposure under different birth scenarios. Over half of studied infants were exposed to at least one furry pet in the prenatal and/or postnatal periods, of which 8% were exposed in pregnancy alone and 46.8% had exposure during both time periods. As a common effect in all birth scenarios, pre- and postnatal pet exposure enriched the abundance of Oscillospira and/or Ruminococcus (P pet exposure (P pet exposure during pregnancy alone and a 69% reduced likelihood (OR 0.31, 95%CI, 0.16-0.58) for exposure in the pre- and postnatal time periods. All of these associations were independent of maternal asthma/allergy status, siblingship, breastfeeding exclusivity and other home characteristics. The impact of pet ownership varies under different birth scenarios; however, in common, exposure to pets increased the abundance of two bacteria, Ruminococcus and Oscillospira, which have been negatively associated with childhood atopy and obesity.

  12. The prognostic value of FET PET at radiotherapy planning in newly diagnosed glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Hoejklint Poulsen, Sidsel [The Finsen Center, Rigshospitalet, Department of Radiation Biology, Copenhagen (Denmark); Center of Diagnostic Investigation, Rigshospitalet, Department of Clinical Physiology, Nuclear Medicine and PET, Copenhagen (Denmark); Urup, Thomas; Grunnet, Kirsten; Skovgaard Poulsen, Hans [The Finsen Center, Rigshospitalet, Department of Radiation Biology, Copenhagen (Denmark); The Finsen Center, Rigshospitalet, Department of Oncology, Copenhagen (Denmark); Jarle Christensen, Ib [University of Copenhagen, Hvidovre Hospital, Laboratory of Gastroenterology, Copenhagen (Denmark); Larsen, Vibeke Andree [Center of Diagnostic Investigation, Rigshospitalet, Department of Radiology, Copenhagen (Denmark); Lundemann Jensen, Michael; Munck af Rosenschoeld, Per [The Finsen Center, Rigshospitalet, Department of Oncology, Copenhagen (Denmark); The Finsen Center, Rigshospitalet, Section of Radiotherapy, Copenhagen (Denmark); Law, Ian [Center of Diagnostic Investigation, Rigshospitalet, Department of Clinical Physiology, Nuclear Medicine and PET, Copenhagen (Denmark)

    2017-03-15

    Glioblastoma patients show a great variability in progression free survival (PFS) and overall survival (OS). To gain additional pretherapeutic information, we explored the potential of O-(2-{sup 18}F-fluoroethyl)-L-tyrosine (FET) PET as an independent prognostic biomarker. We retrospectively analyzed 146 consecutively treated, newly diagnosed glioblastoma patients. All patients were treated with temozolomide and radiation therapy (RT). CT/MR and FET PET scans were obtained postoperatively for RT planning. We used Cox proportional hazards models with OS and PFS as endpoints, to test the prognostic value of FET PET biological tumor volume (BTV). Median follow-up time was 14 months, and median OS and PFS were 16.5 and 6.5 months, respectively. In the multivariate analysis, increasing BTV (HR = 1.17, P < 0.001), poor performance status (HR = 2.35, P < 0.001), O(6)-methylguanine-DNA methyltransferase protein status (HR = 1.61, P = 0.024) and higher age (HR = 1.32, P = 0.013) were independent prognostic factors of poor OS. For poor PFS, only increasing BTV (HR = 1.18; P = 0.002) was prognostic. A prognostic index for OS was created based on the identified prognostic factors. Large BTV on FET PET is an independent prognostic factor of poor OS and PFS in glioblastoma patients. With the introduction of FET PET, we obtain a prognostic index that can help in glioblastoma treatment planning. (orig.)

  13. Pet Ownership by Elderly People: Two New Issues.

    Science.gov (United States)

    Smith, David W. E.; And Others

    1992-01-01

    Examined two issues of pet ownership in mail questionnaire and interview survey of 1,595 older adults over age 60, 377 of whom had a pet. Found evidence that pets were important determinant of housing choice. Many elderly pet owners had made no arrangements for pet if they predecease it or become unable to care for it. (Author/NB)

  14. Pets and the development of allergic sensitization.

    Science.gov (United States)

    Simpson, Angela; Custovic, Adnan

    2005-05-01

    Sensitization to pets remains a risk factor for asthma and rhinitis, and can occur in people who have never lived with a pet. Several reports have indicated that living with a pet reduces the risk for becoming sensitized to that pet. Having a pet in the home gives exposure to more than just allergens. In areas with high frequency of pet ownership, community exposure to pet allergens is almost certainly sufficient to induce sensitization among non-pet owners. In this review, we examine the results of recent studies that have investigated the relationship between pet ownership, specific sensitization to that pet, and allergic sensitization in general. For cat ownership, the results are inconsistent between studies of similar design, with some studies suggesting an increase in risk and others a decrease among cat owners. For dogs, results are more consistent, generally suggesting that owning a dog has no effect or indeed may be protective against the development of specific sensitization to dog and allergic sensitization in general.

  15. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour.

    Science.gov (United States)

    Hawkins, Roxanne D; Williams, Joanne M; Scottish Society For The Prevention Of Cruelty To Animals Scottish Spca

    2017-05-06

    Attachment to pets has an important role in children's social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  16. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    Directory of Open Access Journals (Sweden)

    Roxanne D. Hawkins

    2017-05-01

    Full Text Available Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life and pets (such as humane treatment. This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  17. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    Science.gov (United States)

    Hawkins, Roxanne D.; Williams, Joanne M.

    2017-01-01

    Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood. PMID:28481256

  18. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  19. Role of 18FDG-PET imaging in management of recurrent ovarian carcinoma

    International Nuclear Information System (INIS)

    Dadparvar, S.; Kumar, R.; Lee, B.; Zhuang Hongming; Alavi, A.

    2004-01-01

    Introduction: Serial assays of CA-125 have been established as a tumor marker for monitoring recurrent epithelial ovarian carcinoma following initial surgery and chemotherapy. The anatomical imaging is performed to localize the tumor site for possible resection. This retrospective study analyzed the efficacy of 18FDG-PET to detect suspected recurrent ovarian carcinoma. Materials and methods: Sixty consecutive patients, age range 40-83 years, mean age 55.8 years with known Ovarian Carcinoma underwent 76 PET-FDG studies. All patients were status post total abdominal Hysterectomy and bilateral salpingo- oopherectomy and were treated with chemo and/or radiation therapy. The imaging was performed at approximately 60 minutes following intravenous injection of average dose of 5.7 mCi 18FDG. Fifty concomitant CA-125 serum assays and 58 anatomical imaging (CT/MRI) were available for comparison. Thirty-eight combined PET, CA-125 and CT/MRI studies were available for evaluation. In addition to ovarian carcinoma in fifteen patients secondary tumors including lung, breast and colon carcinoma and lymphoma were diagnosed. The final diagnoses were based on clinical follow up and other relevant findings. Results: The comparison of the three studies including CA-125, 18FDG-PET and anatomical imaging Revealed. There was no significant difference among all three studies with regard to the diagnosis of recurrent ovarian carcinoma (p=ns). The combined studies improved the sensitivity to 0.98. Among 18 patients with normal CA-125 level, 5 had negative PET and 13 had positive PET studies. Conclusion: 18FDG-PET studies play a major role in detection of recurrent ovarian carcinoma. The Combination of all three studies improves the sensitivity. We recommend routine use of 18FDG- PET in the management of recurrent ovarian carcinoma especially when anatomical imaging is inconclusive. (authors)

  20. Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Knudsen, Andreas; Hag, Anne Mette Fisker

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of 18F-FDG. PET/MR was performed a median of 131 ...

  1. Comparison of the prognostic values of {sup 68}Ga-DOTANOC PET/CT and {sup 18}F-FDG PET/CT in patients with well-differentiated neuroendocrine tumor

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Punit; Naswa, Niraj; Kc, Sudhir Suman; Yadav, Yashwant; Kumar, Rakesh; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, Ansari Nagar, New Delhi (India); Alvarado, Luis Andres; Dwivedi, Alok Kumar [Texas Tech University Health Sciences Center, Division of Biostatistics and Epidemiology, El Paso, TX (United States); Ammini, Ariachery C. [All India Institute of Medical Sciences, Department of Endocrinology and Metabolism, New Delhi (India)

    2014-12-15

    To determine the prognostic value of {sup 68}Ga-DOTANOC PET/CT in patients with well-differentiated neuroendocrine tumor (NET), and to compare the prognostic value with that of {sup 18}F-FDG PET/CT and other conventional clinicopathological prognostic factors. Data from 37 consecutive patients (age 46.6 ± 13.5 years, 51 % men) with well-differentiated NET who underwent {sup 68}Ga-DOTANOC PET/CT and {sup 18}F-FDG PET/CT were analyzed. All patients underwent a baseline visit with laboratory and radiological examinations. Clinical and imaging follow-up was performed in all patients. Progression-free survival (PFS) was measured from the date of the first PET/CT scan to the first documentation of progression of disease. {sup 68}Ga-DOTANOC PET/CT was positive in 37 of the 37 patients and {sup 18}F-FDG PET/CT was positive in 21. During follow-up 10 patients (27 %) showed progression of disease and 27 (73 %) showed no progression (24 stable disease, 3 partial response). The median follow-up was 25 months (range 2 - 52 months). Among the variables evaluated none was significantly different between the progressive disease and nonprogressive disease groups, with only SUVmax on {sup 68}Ga-DOTANOC PET/CT being borderline significant (P = 0.073). In the univariate analysis for PFS outcome, SUVmax on {sup 68}Ga-DOTANOC PET/CT (HR 0.122, 95 % CI 0.019 - 0.779; P = 0.026) and histopathological tumor grade (HR 4.238, 95 % CI 1.058 - 16.976; P = 0.041) were found to be associated with PFS. Other factors including age, sex, primary site, Ki-67 index, TNM stage, {sup 18}F-FDG PET/CT status (positive/negative), SUVmax on {sup 18}F-FDG PET/CT and type of treatment were not significant. In multivariable analysis, only SUVmax on {sup 68}Ga-DOTANOC PET/CT was found to be an independent positive predictor of PFS (HR 0.122, 95 % CI 0.019 - 0.779; P = 0.026). SUVmax measured on {sup 68}Ga-DOTANOC PET/CT is an independent, positive prognostic factor in patients with well-differentiated NET and

  2. Pseudarthrosis after lumbar spinal fusion: the role of 18F-fluoride PET/CT

    International Nuclear Information System (INIS)

    Peters, Marloes; Willems, Paul; Jutten, Liesbeth; Arts, Chris; Rhijn, Lodewijk van; Weijers, Rene; Wierts, Roel; Urbach, Christian; Brans, Boudewijn

    2015-01-01

    Painful pseudarthrosis is one of the most important indications for (revision) surgery after spinal fusion procedures. If pseudarthrosis is the source of recurrent pain it may require revision surgery. It is therefore of great clinical importance to ascertain if it is the source of such pain. The correlation between findings on conventional imaging (plain radiography and CT) and clinical well-being has been shown to be moderate. The goal of this study was to determine the possible role of 18 F-fluoride PET in patients after lumbar spinal interbody fusion by investigating the relationship between PET/CT findings and clinical function and pain. A cohort of 36 patients was retrospectively included in the study after 18 F-fluoride PET/CT for either persistent or recurrent low back pain (18 patients) or during routine postoperative investigation (18 patients) between 9 and 76 months and 11 and 14 months after posterior lumbar interbody fusion, respectively. Sixty minutes after intravenous injection of 156 - 263 MBq (mean 199 MBq, median 196 MBq) 18 F-fluoride, PET and CT images were acquired using an integrated PET/CT scanner, followed by a diagnostic CT scan. Two observers independently scored the images. The number of bony bridges between vertebrae was scored on the CT images to quantify interbody fusion (0, 1 or 2). Vertebral endplate and intervertebral disc space uptake were evaluated visually as well as semiquantitatively following 18 F-fluoride PET. Findings on PET and CT were correlated with clinical wellbeing as measured by validated questionnaires concerning general daily functioning (Oswestry Disability Index), pain (visual analogue scale) and general health status (EuroQol). Patients were divided into three categories based on these questionnaire scores. No correlation was found between symptom severity and fusion status. However, 18 F-fluoride activity in the vertebral endplates was significantly higher in patients in the lowest Oswestry Disability Index

  3. Pseudarthrosis after lumbar spinal fusion: the role of {sup 18}F-fluoride PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Marloes; Willems, Paul; Jutten, Liesbeth; Arts, Chris; Rhijn, Lodewijk van [Maastricht University Medical Center, Department of Orthopedic Surgery, Postbox 5800, Maastricht (Netherlands); Weijers, Rene; Wierts, Roel; Urbach, Christian; Brans, Boudewijn [Maastricht University Medical Center, Radiology /Nuclear Medicine, Maastricht (Netherlands)

    2015-11-15

    Painful pseudarthrosis is one of the most important indications for (revision) surgery after spinal fusion procedures. If pseudarthrosis is the source of recurrent pain it may require revision surgery. It is therefore of great clinical importance to ascertain if it is the source of such pain. The correlation between findings on conventional imaging (plain radiography and CT) and clinical well-being has been shown to be moderate. The goal of this study was to determine the possible role of {sup 18}F-fluoride PET in patients after lumbar spinal interbody fusion by investigating the relationship between PET/CT findings and clinical function and pain. A cohort of 36 patients was retrospectively included in the study after {sup 18}F-fluoride PET/CT for either persistent or recurrent low back pain (18 patients) or during routine postoperative investigation (18 patients) between 9 and 76 months and 11 and 14 months after posterior lumbar interbody fusion, respectively. Sixty minutes after intravenous injection of 156 - 263 MBq (mean 199 MBq, median 196 MBq) {sup 18}F-fluoride, PET and CT images were acquired using an integrated PET/CT scanner, followed by a diagnostic CT scan. Two observers independently scored the images. The number of bony bridges between vertebrae was scored on the CT images to quantify interbody fusion (0, 1 or 2). Vertebral endplate and intervertebral disc space uptake were evaluated visually as well as semiquantitatively following {sup 18}F-fluoride PET. Findings on PET and CT were correlated with clinical wellbeing as measured by validated questionnaires concerning general daily functioning (Oswestry Disability Index), pain (visual analogue scale) and general health status (EuroQol). Patients were divided into three categories based on these questionnaire scores. No correlation was found between symptom severity and fusion status. However, {sup 18}F-fluoride activity in the vertebral endplates was significantly higher in patients in the lowest

  4. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    DEFF Research Database (Denmark)

    Berthelsen, A K; Holm, S; Loft, A

    2005-01-01

    PURPOSE: If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation...... correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can...... be used for PET attenuation without reducing the clinical value of the PET scan. METHODS: A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT...

  5. FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    DEFF Research Database (Denmark)

    Boellaard, Ronald; O'Doherty, Mike J; Weber, Wolfgang A

    2010-01-01

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about[18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed tomogr......-computed tomography (PET/CT) and is provided to help the physician and physicist to assist to carrying out,interpret, and document quantitative FDG PET/CT examinations,but will concentrate on the optimisation of diagnostic quality and quantitative information....

  6. Utility of PET in gynecological cancer

    International Nuclear Information System (INIS)

    Choi, Chang Woon

    2002-01-01

    Clinical application of positron emission tomography (PET) is rapidly increasing for the detection and staging of cancer at whole-body studies performed with 2-[fluorine-18] fluoro-2-deoxy-D-glucose (FDG). Although many cancers can be detected by FDG-PET, there has been limited clinical experience with FDG-PET for the detection of gynecological cancers including malignancies in uterus and ovary. FDG-PET can show foci of metastatic disease that may not be apparent at conventional anatomic imaging and can aid in the characterization of indeterminate soft-tissue masses. Most gynecological cancers need to surgical management. FDG-PET can improve the selection of patients for surgical treatment and thereby reduce the morbidity and mortality associated with inappropriate surgery. FDG-PET is also useful for the early detection of recurrence and the monitoring of therapeutic effect. In this review, I discuss the clinical feasibility and imitations of this imaging modality in patients with gynecological cancers

  7. Combined PET/MR imaging in neurology

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Ladefoged, Claes Nøhr; Beyer, Thomas

    2014-01-01

    on a transaxial T1w-MR image traversing the central basal ganglia. We report the relative difference (%) of the mean ROI values for (A)-(C) in reference to PET/CT (D). In a separate phantom experiment a 2L plastic bottle was layered with approximately 12mm of Gypsum plaster to mimic skull bone. The phantom......AIM: Combined PET/MR systems have now become available for clinical use. Given the lack of integrated standard transmission (TX) sources in these systems, attenuation and scatter correction (AC) must be performed using the available MR-images. Since bone tissue cannot easily be accounted for during...... MR-AC, PET quantification can be biased, in particular, in the vicinity of the skull. Here, we assess PET quantification in PET/MR imaging of patients using phantoms and patient data. MATERIALS AND METHODS: Nineteen patients referred to our clinic for a PET/CT exam as part of the diagnostic...

  8. PET/MRI in cancer patients

    DEFF Research Database (Denmark)

    Kjær, Andreas; Loft, Annika; Law, Ian

    2013-01-01

    Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear...... described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision...... that PET/MRI in oncology will prove to become a valuable addition to PET/CT in diagnosing, tailoring and monitoring cancer therapy in selected patient populations....

  9. Laboratory and cyclotron requirements for PET research

    International Nuclear Information System (INIS)

    Schlyer, D.J.

    1993-01-01

    The requirements for carrying out PET research can vary widely depending on the type of basic research being carried out and the extent of a clinical program at a particular center. The type of accelerator and laboratory facilities will, of course, depend on the exact mix. These centers have been divided into four categories. 1. Clinical PET with no radionuclide production facilities, 2. clinical PET with some radionuclide production facilities, 3. clinical PET with research support, and 4. a PET research facility developing new tracers and exploring clinical applications. Guidelines for the choice of an accelerator based on these categories and the practical yields of the common nuclear reactions for production of PET isotopes have been developed and are detailed. Guidelines as to the size and physical layout of the laboratory space necessary for the synthesis of various radiopharmaceuticals have also been developed and are presented. Important utility and air flow considerations are explored

  10. Pet Store Loyalty in Malaysia

    OpenAIRE

    Leong, Yuen Yee

    2010-01-01

    Loyalty is open studied topic within the retailing and marketing discipline. A strong and profitable base of loyal customers is an asset to any organization, and is one of the epitomes of success for a company. The flourishing of large, specialty niche retailers like Starbucks, Victoria Secret and Barnes & Noble are stellar success stories that thrive on their troop of staunch followers. Pet retailing is a niche market which has its own interesting market characteristics. The emergence of ...

  11. Child vs. Pet: The Effect of Abortion Legalization on the Demand for Pets

    OpenAIRE

    Youjin Hahn; Liang Choon Wang; Hee-Seung Yang

    2012-01-01

    This paper examines whether abortion legalization led to increased demand for pets in the United States. We compare women living in early-legalizing states, whose peak childbearing years occurred in the early 1970s, to women in other states and cohorts and estimate their likelihood of pet ownership and time spent on pets after their peak childbearing years were over. We find the probability of owning any pet is approximately 9.6 percentage points higher for women affected by abortion legaliza...

  12. Impact of the intensity of the pretransplantation conditioning regimen in patients with prior invasive aspergillosis undergoing allogeneic hematopoietic stem cell transplantation: A retrospective survey of the Infectious Diseases Working Party of the European Group for Blood and Marrow Transplantation.

    Science.gov (United States)

    Martino, Rodrigo; Parody, Rocio; Fukuda, Takahiro; Maertens, Johan; Theunissen, Koen; Ho, Aloysius; Mufti, Ghulam J; Kroger, Nicolaus; Zander, Arnold R; Heim, Dominik; Paluszewska, Monika; Selleslag, Dominik; Steinerova, Katerina; Ljungman, Per; Cesaro, Simone; Nihtinen, Anna; Cordonnier, Catherine; Vazquez, Lourdes; López-Duarte, Monica; Lopez, Javier; Cabrera, Rafael; Rovira, Montserrat; Neuburger, Stefan; Cornely, Oliver; Hunter, Ann E; Marr, Kieren A; Dornbusch, Hans Jürgen; Einsele, Hermann

    2006-11-01

    In this retrospective study, we analyzed the outcomes of 129 patients who underwent an allogeneic hematopoietic stem cell transplantation (allo-HSCT) and had a history of probable or proven invasive aspergillosis (IA), of whom 57 (44%) received a reduced-intensity conditioning (RIC). Overall, 27 patients with IA progressed after the allo-HSCT (cumulative incidence [CumInc] at 2 years, 22%). The variables that increased the 2-year CumInc of IA progression were (1) longer duration of neutropenia after transplantation; (2) advanced status of the underlying disease; and (3) less than 6 weeks from start of systemic anti-Aspergillus therapy and the allo-HSCT. In addition, (4) conventional myeloablative conditioning increased the risk of progression early after transplantation (before day 30) only, while 3 variables increased the risk beyond day 30 were (5) cytomegalovirus disease; (6) bone marrow or cord blood as source of stem cells; and (7) grades II to IV acute graft-versus-host disease (GVHD). A risk model for progression was generated, defined as low (0-1 risk factors, 6% incidence), intermediate (2-3 risk factors, 27% incidence), or high risk (> or = 3 risk factors, 72% incidence [P < .001]). These findings may help in the interpretation and design of future studies on secondary prophylaxis of IA after an allo-HSCT.

  13. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  14. Human salmonellosis associated with exotic pets.

    OpenAIRE

    Woodward, D L; Khakhria, R; Johnson, W M

    1997-01-01

    During the period from 1994 to 1996, an increase in the number of laboratory-confirmed cases of human salmonellosis associated with exposure to exotic pets including iguanas, pet turtles, sugar gliders, and hedgehogs was observed in Canada. Pet turtle-associated salmonellosis was recognized as a serious public health problem in the 1960s and 1970s, and in February 1975 legislation banning the importation of turtles into Canada was enacted by Agriculture Canada. Reptile-associated salmonellosi...

  15. Towards enhanced PET quantification in clinical oncology.

    Science.gov (United States)

    Zaidi, Habib; Karakatsanis, Nicolas

    2018-01-01

    Positron emission tomography (PET) has, since its inception, established itself as the imaging modality of choice for the in vivo quantitative assessment of molecular targets in a wide range of biochemical processes underlying tumour physiology. PET image quantification enables to ascertain a direct link between the time-varying activity concentration in organs/tissues and the fundamental parameters portraying the biological processes at the cellular level being assessed. However, the quantitative potential of PET may be affected by a number of factors related to physical effects, hardware and software system specifications, tracer kinetics, motion, scan protocol design and limitations in current image-derived PET metrics. Given the relatively large number of PET metrics reported in the literature, the selection of the best metric for fulfilling a specific task in a particular application is still a matter of debate. Quantitative PET has advanced elegantly during the last two decades and is now reaching the maturity required for clinical exploitation, particularly in oncology where it has the capability to open many avenues for clinical diagnosis, assessment of response to treatment and therapy planning. Therefore, the preservation and further enhancement of the quantitative features of PET imaging is crucial to ensure that the full clinical value of PET imaging modality is utilized in clinical oncology. Recent advancements in PET technology and methodology have paved the way for faster PET acquisitions of enhanced sensitivity to support the clinical translation of highly quantitative four-dimensional (4D) parametric imaging methods in clinical oncology. In this report, we provide an overview of recent advances and future trends in quantitative PET imaging in the context of clinical oncology. The pros/cons of the various image-derived PET metrics will be discussed and the promise of novel methodologies will be highlighted.

  16. Pet Ownership and Evacuation Prior to Hurricane Irene

    Directory of Open Access Journals (Sweden)

    Nick Rohrbaugh

    2012-09-01

    Full Text Available Pet ownership has historically been one of the biggest risk factors for evacuation failure prior to natural disasters. The forced abandonment of pets during Hurricane Katrina in 2005 made national headlines and led to the passage of the Pet Evacuation and Transportation Standards Act (PETS, 2006 which mandated local authorities to plan for companion animal evacuation. Hurricane Irene hit the East Coast of the United States in 2011, providing an excellent opportunity to examine the impact of the PETS legislation on frequency and ease of evacuation among pet owners and non-pet owners. Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones completed questionnaires assessing their experiences during the hurricane and symptoms of depression, PTSD, dissociative experiences, and acute stress. Pet ownership was not found to be a statistical risk factor for evacuation failure. However, many pet owners who failed to evacuate continue to cite pet related reasons.

  17. Pet Ownership and Evacuation Prior to Hurricane Irene.

    Science.gov (United States)

    Hunt, Melissa G; Bogue, Kelsey; Rohrbaugh, Nick

    2012-09-28

    Pet ownership has historically been one of the biggest risk factors for evacuation failure prior to natural disasters. The forced abandonment of pets during Hurricane Katrina in 2005 made national headlines and led to the passage of the Pet Evacuation and Transportation Standards Act (PETS, 2006) which mandated local authorities to plan for companion animal evacuation. Hurricane Irene hit the East Coast of the United States in 2011, providing an excellent opportunity to examine the impact of the PETS legislation on frequency and ease of evacuation among pet owners and non-pet owners. Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones completed questionnaires assessing their experiences during the hurricane and symptoms of depression, PTSD, dissociative experiences, and acute stress. Pet ownership was not found to be a statistical risk factor for evacuation failure. However, many pet owners who failed to evacuate continue to cite pet related reasons.

  18. F-18-FLT PET for visualization of laryngeal cancer : Comparison with F-18-FDG PET

    NARCIS (Netherlands)

    Cobben, DCP; van der Laan, BFAM; Maas, B; Vaalburg, W; Suurmeijer, AJH; Hoekstra, HJ; Jager, PL; Elsinga, PH

    The feasibility of F-18-3'-fluoro-3'-deoxy-L-thymidine PET (FLT PET) for detecting laryngeal cancer was investigated and compared with F-18-FDG PET. Methods: Eleven patients diagnosed with or strongly suspected of having recurrent laryngeal cancer and 10 patients with histologically proven primary

  19. The AX-PET project Demonstration of a high resolution axial 3D PET

    CERN Document Server

    Bolle, E; Casella, C; Chesi, E; Clinthorne, N; Cochran, E; De Leo, R; Dissertori, G; Djambazov, G; Fanti, V; Honscheid, K; Huh, S; Johnson, I; Joram, C; Kagan, H; Lustermann, W; Meddi, F; Nappi, E; Nessi-Tedaldi, F; Oliver, J F; Pauss, P; Rafecas, M; Renker, D; Rudge, A; Schinzel, D; Schneider, T; Seguinot, J; Smith, S; Solevi, P; Stapnes, S; Weilhammer, P

    2010-01-01

    The AX-PET is a new geometrical concept for a high resolution 3D PET scanner, based on matrices of axially oriented LYSO crystals interleaved by stacks of WLS, both individually read out by G-APDs. A PET demonstrator, based on two detector modules used in coincidence, is currently under construction.

  20. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    Abstract. The objective of the present study was basic understanding of the formation of thin film morphology by spin coating using reorganized polyethylene terephthalate (r-PET) and multiwalled carbon nanotubes (MWCNTs) as fillers in PET. A study of the correlation between physical properties of the PET films and its ...

  1. Radiology for PET/CT reporting

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina; Fanti, Stefano; Zanoni, Lucia [Univ. Hospital Sant Orsola-Malpighi, Bologna (Italy). Dept. of Nuclear Medicine

    2014-07-01

    Offers rapid access to slice by slice CT descriptions of anatomical structures from PET/CT studies. Presents images and descriptions of CT findings that may be detected while reviewing PET/CT scans. Includes principal MRI findings in diseases susceptible to PET/CT evaluation. Reading PET/CT scans is sometimes challenging. Not infrequently, abnormal findings on CT images are functionally silent and therefore difficult for nuclear medicine practitioners to interpret. Furthermore, in general only a low-dose CT scan is produced as part of the combined PET/CT study, and the resulting CT images may prove suboptimal for image interpretation. This atlas is designed to enable nuclear medicine practitioners who routinely read PET/CT scans to recognize the most common CT abnormalities. Slice-by-slice descriptions are provided of anatomical structures as visualized on CT scans obtained in PET/CT studies. The CT findings that may be detected while reviewing PET/CT scans of various body regions and conditions are then illustrated and fully described. The concluding section of the book is devoted to the principal MRI findings in diseases which cannot be evaluated using PETs/CTs.

  2. Progress of PET imaging in Schizophrenia

    International Nuclear Information System (INIS)

    Cai Li; Gao Shuo

    2011-01-01

    PET is an important functional neuroimaging technique that can be used to assessment of cerebral metabolic activity and blood flow and identifies the distribution of important neurotransmitters in the human brain. Compared with other conventional imaging techniques, PET enables regional cerebral glucose metabolism, blood flow, dopaminergic and serotonergic receptor function to be assessed qualitatively and quantitatively. In recent years, PET increasingly being used greatly to advance our understanding of the neurobiology and pathophysiology of schizophrenia. This review focuses on the use of PET tracers in identifying regional brain abnormalities and regions associated with cognitive functioning in schizophrenia. (authors)

  3. PET scanning in plastic and reconstructive surgery.

    Science.gov (United States)

    Liodaki, Eirini; Eirini, Liodaki; Liodakis, Emmanouil; Emmanouil, Liodakis; Papadopoulos, Othonas; Othonas, Papadopoulos; Machens, Hans-Günther; Hans-Günther, Machens; Papadopulos, Nikolaos A; Nikolaos, Papadopulos A

    2012-02-01

    In this report we highlight the use of PET scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge.

  4. Investigation progress of PET reporter gene imaging

    International Nuclear Information System (INIS)

    Chen Yumei; Huang Gang

    2006-01-01

    Molecular imaging for gene therapy and gene expression has been more and more attractive, while the use of gene therapy has been widely investigated and intense research have allowed it to the clinical setting in the last two-decade years. In vivo imaging with positron emission tomography (PET) by combination of appropriate PET reporter gene and PET reporter probe could provide qualitative and quantitative information for gene therapy. PET imaging could also obtain some valuable parameters not available by other techniques. This technology is useful to understand the process and development of gene therapy and how to apply it into clinical practice in the future. (authors)

  5. PET-Computed Tomography in Veterinary Medicine.

    Science.gov (United States)

    Randall, Elissa K

    2016-05-01

    PET/CT is an advanced imaging modality that is becoming more commonly used in veterinary medicine. It is most commonly used to image patients with cancer, and the most frequently used radiopharmaceutical is F-18 FDG. F-18 FDG is a glucose analog that highlights areas of increased glucose metabolism on the PET images. CT images provide excellent anatomic depiction and aid in interpretation of the PET data. Many types of cancer are hypermetabolic on PET/CT scans, but normal structures and areas of inflammation are also hypermetabolic, so knowledge of normal imaging and cytologic or histopathologic evaluation of lesions is essential. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. FDG-PET in Hodgkin lymphoma

    International Nuclear Information System (INIS)

    Kobe, C.; Dietlein, M.; Schicha, H.; Sabri, O.; Kluge, R.; Schober, O.

    2008-01-01

    The high negative predictive value of FDG-PET in therapy control of Hodgkin lymphoma is proven by the data acquired up to now. Thus, the analysis of the HD15 trial has shown that consolidation radiotherapy might be omitted in PET negative patients after effective chemotherapy. Further response adapted therapy guided by PET seems to be a promising approach in reducing the toxicity for patients undergoing chemotherapy. The criteria used for the PET interpretation have been standardized by the German study groups for Hodgkin lymphoma patients and will be reevaluated in the current studies. (orig.)

  7. Pet food safety: the roles of government, manufacturers, and veterinarians.

    Science.gov (United States)

    Eirmann, Laura; Cowell, Christopher; Thompson, Larry

    2012-01-01

    Food safety is of concern for both human and companion animal health. Government agencies, pet food manufacturers, and veterinarians play crucial roles in ensuring the safety of pet food and safeguarding pets and their owners. Recent legislation will increase the governmental role in regulating pet food and will affect many manufacturers. Veterinarians continue to play a vital role by recognizing and reporting pet food safety issues and by educating clients on matters related to pet food safety.

  8. Pet ownership, social support, and one-year survival after acute myocardial infarction in the Cardiac Arrhythmia Suppression Trial (CAST).

    Science.gov (United States)

    Friedmann, E; Thomas, S A

    1995-12-15

    Social support and pet ownership, a nonhuman form of social support, have both been associated with increased coronary artery disease survival. The independent effects of pet ownership, social support, disease severity, and other psychosocial factors on 1-year survival after acute myocardial infarction are examined prospectively. The Cardiac Arrhythmia Suppression Trial provided physiologic data on a group of post-myocardial infarction patients with asymptomatic ventricular arrhythmias. An ancillary study provided psychosocial data, including pet ownership, social support, recent life events, future life events, anxiety, depression, coronary prone behavior, and expression of anger. Subjects (n = 424) were randomly selected from patients attending participating Cardiac Arrhythmia Suppression Trial sites and completed baseline psychosocial questionnaires. One year survival data were obtained from 369 patients (87%), of whom 112 (30.4%) owned pets and 20 (5.4%) died. Logistic regression indicates that high social support (p owning a pet (p = 0.085) tend to predict survival independent of physiologic severity and demographic and other psychosocial factors. Dog owners (n = 87, 1 died) are significantly less likely to die within 1 year than those who did not own dogs (n = 282, 19 died; p pet ownership and social support are significant predictors of survival, independent of the effects of the other psychosocial factors and physiologic status. These data confirm and extend previous findings relating pet ownership and social support to survival among patients with coronary artery disease.

  9. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  10. FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0

    NARCIS (Netherlands)

    Boellaard, R.; O'Doherty, M.J.; Weber, W.A.; Mottaghy, F.M.; Lonsdale, M.N.; Stroobants, S.G.; Oyen, W.J.G.; Kotzerke, J.; Hoekstra, O.S.; Pruim, J.; Marsden, P.K.; Tatsch, K.; Hoekstra, C.J.; Visser, E.P.; Arends, B.; Verzijlbergen, F.J.; Zijlstra, J.M.; Comans, E.F.I.; Lammertsma, A.A.; Paans, A.M.; Willemsen, A.T.; Beyer, T.; Bockisch, A.; Schaefer-Prokop, C.; Delbeke, D.; Baum, R.P.; Chiti, A.; Krause, B.J.

    2010-01-01

    The aim of this guideline is to provide a minimum standard for the acquisition and interpretation of PET and PET/CT scans with [18F]-fluorodeoxyglucose (FDG). This guideline will therefore address general information about [18F]-fluorodeoxyglucose (FDG) positron emission tomography-computed

  11. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  12. Pet allergy: how important for Turkey where there is a low pet ownership rate.

    Science.gov (United States)

    Mungan, Dilşad; Celik, Gülfem; Bavbek, Sevim; Misirligil, Zeynep

    2003-01-01

    Exposure and sensitization to allergens derived from cats/dogs have been shown to represent an important risk factor for allergic respiratory diseases. So far, there has not been any study exploring cat/dog sensitization and related factors in our geographic location. The aim of this study was to determine the sensitization to cats/dogs in a group of patients with rhinitis and/or asthma and to evaluate the relationship between current and childhood exposure and sensitivity to pets. Three hundred twelve consecutive subjects with asthma and/or rhinitis were included in the study and were asked to reply a questionnaire concerning past and current pet ownership and presence of pet-related respiratory symptoms. After performing skin-prick tests, subjects were allocated into three groups: group 1 (n = 103), subjects with nonatopic asthma; group 2 (n = 54), allergic rhinitis and/or asthma patients with pet allergy; group 3 (n = 155), allergic rhinitis and/or asthma patients without pet allergy. Pet hypersensitivity was detected in 54 of 209 atopic subjects (25.8%). There was no difference in the rates of past pet ownership among subjects with (29.6%) and without (23.8%) pet allergy. However, the ratio of current pet ownership was higher in atopic patients with pet allergy (16.6%) than in nonatopic subjects (2.9%; p = 0.02). The prevalence of sensitization to pets in current owners (42.8%) was higher than prevalence of sensitization in patients who never had a pet (22.6%; p = 0.002; odds ratio, 2.67) and who owned a pet at childhood (28.2%; p = 0.038; odds ratio, 1.9). Thirteen subjects (13/54; 24%) described respiratory symptoms when exposed to cats and/or dogs. Rate of past pet ownership was similar in symptomatic and asymptomatic subjects with pet allergy (30.7% versus 29.2%; p > 0.05). Rate of current per ownership was higher in symptomatic subjects than in asymptomatic subjects with pet sensitivity (38.4% versus 9.5%; p pet allergens have the potential to become an

  13. A proposal of an open PET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Inaniwa, Taku [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Minohara, Shinichi [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yoshida, Eiji [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Inadama, Naoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Nishikido, Fumihiko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Shibuya, Kengo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Lam, Chih Fung [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Murayama, Hideo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan)

    2008-02-07

    The long patient port of a PET scanner tends to put stress on patients, especially patients with claustrophobia. It also prevents doctors and technicians from taking care of patients during scanning. In this paper, we proposed an 'open PET' geometry, which consists of two axially separated detector rings. A long and continuous field-of-view (FOV) including a 360 deg. opened gap between two detector rings can be imaged enabling a fully 3D image reconstruction of all the possible lines-of-response. The open PET will become practical if iterative image reconstruction methods are applied even though image reconstruction of the open PET is analytically an incomplete problem. First we implemented a 'masked' 3D ordered subset expectation maximization (OS-EM) in which the system matrix was obtained from a long 'gapless' scanner by applying a mask to detectors corresponding to the open space. Next, in order to evaluate imaging performance of the proposed open PET geometry, we simulated a dual HR+ scanner (ring diameter of D = 827 mm, axial length of W = 154 mm x 2) separated by a variable gap. The gap W was the maximum limit to have axially continuous FOV of 3W though the maximum diameter of FOV at the central slice was limited to D/2. Artifacts, observed on both sides of the open space when the gap exceeded W, were effectively reduced by inserting detectors partially into unnecessary open spaces. We also tested the open PET geometry using experimental data obtained by the jPET-D4. The jPET-D4 is a prototype brain scanner, which has 5 rings of 24 detector blocks. We simulated the open jPET-D4 with a gap of 66 mm by eliminating 1 block-ring from experimental data. Although some artifacts were seen at both ends of the opened gap, very similar images were obtained with and without the gap. The proposed open PET geometry is expected to lead to realization of in-beam PET, which is a method for an in situ monitoring of charged particle therapy, by

  14. The Use of 18F-FDG-PET/CT for Diagnosis and Treatment Monitoring of Inflammatory and Infectious Diseases

    Directory of Open Access Journals (Sweden)

    Andor W. J. M. Glaudemans

    2013-01-01

    Full Text Available FDG-PET, combined with CT, is nowadays getting more and more relevant for the diagnosis of several infectious and inflammatory diseases and particularly for therapy monitoring. Thus, this paper gives special attention to the role of FDG-PET/CT in the diagnosis and therapy monitoring of infectious and inflammatory diseases. Enough evidence in the literature already exists about the usefulness of FDG-PET/CT in the diagnosis, management, and followup of patients with sarcoidosis, spondylodiscitis, and vasculitis. For other diseases, such as inflammatory bowel diseases, rheumatoid arthritis, autoimmune pancreatitis, and fungal infections, hard evidence is lacking, but studies also point out that FDG-PET/CT could be useful. It is of invaluable importance to have large prospective multicenter studies in this field to provide clear answers, not only for the status of nuclear medicine in general but also to reduce high costs of treatment.

  15. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT

    International Nuclear Information System (INIS)

    Wiesmueller, Marco; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; Gall, Carl C. von; Quick, Harald H.; Navalpakkam, Bharath; Lell, Michael M.; Uder, Michael; Ritt, Philipp

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were 18 F-deoxyglucose (FDG), 18 F-ethylcholine (FEC) and 68 Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET CT ) and from PET/MR (PET MR ) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV max and SUV avg , respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET CT were identified by PET MR (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET CT and by PET MR . In four patients, more lesions were identified by PET MR than by PET CT , in one patient PET CT revealed an additional focus compared to PET MR . The mean SUV max and SUV avg of all lesions determined by PET MR were by 21 % and 11 % lower, respectively, than the values determined by PET CT (p CT and PET MR were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET MR and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations. (orig.)

  16. (68)Ga-DOTATOC PET and gene expression profile in patients with neuroendocrine carcinomas

    DEFF Research Database (Denmark)

    Olsen, Ingrid H; Langer, Seppo W; Federspiel, Birgitte H

    2016-01-01

    Somatostatin receptor expression on both protein and gene expression level was compared with in vivo (68)Ga-DOTATOC PET/CT in patients with neuroendocrine carcinomas (NEC). Twenty-one patients with verified NEC who underwent a (68)Ga-DOTATOC PET/CT between November 2012 and May 2014, were...... retrospectively included. By real-time polymerase chain reaction, we quantitatively determined the gene expression of several genes and compared with (68)Ga-DOTATOC PET uptake. By immunohistochemistry we qualitatively studied the expression of assorted proteins in NEC. The median age at diagnosis was 68 years...... (range 41-84) years. All patients had WHO performance status 0-1. Median Ki67 index was 50% (range 20-100%). Gene expression of somatostatin receptor subtype (SSTR) 2 and Ki67 were both positively correlated to the (68)Ga-DOTATOC uptake (r=0.89; p

  17. Role of FDG-PET and PET/CT in the diagnosis of prolonged febrile states

    Energy Technology Data Exchange (ETDEWEB)

    Jaruskova, M.; Belohlavek, O. [Na Homolce Hospital, PET Center, Prague 5 (Czech Republic)

    2006-08-15

    The role of FDG-PET and PET/CT in patients whose main symptom is prolonged fever has not yet been defined. We addressed this topic in a retrospective study. A total of 124 patients (referred between May 2001 and December 2004) with fever of unknown origin or prolonged fever due to a suspected infection of a joint or vascular prosthesis were included in the study. The patients underwent either FDG-PET or FDG-PET/CT scanning. Sixty-seven patients had a negative focal FDG-PET finding; in this group the method was regarded as unhelpful in determining a diagnosis, and no further investigation was pursued. We tried to obtain clinical confirmation for all patients with positive PET findings. Fifty-seven (46%) patients had positive FDG-PET findings. In six of them no further clinical information was available. Fifty-one patients with positive PET findings and 118 patients in total were subsequently evaluated. Systemic connective tissue disease was confirmed in 17 patients, lymphoma in three patients, inflammatory bowel disease in two patients, vascular prosthesis infection in seven patients, infection of a hip or knee replacement in seven patients, mycotic aneurysm in two patients, abscess in four patients and AIDS in one patient. In eight (16%) patients the finding was falsely positive. FDG-PET or PET/CT contributed to establishing a final diagnosis in 84% of the 51 patients with positive PET findings and in 36% of all 118 evaluated patients with prolonged fever. (orig.)

  18. Human health implications of Salmonella-contaminated natural pet treats and raw pet food.

    Science.gov (United States)

    Finley, Rita; Reid-Smith, Richard; Weese, J Scott

    2006-03-01

    Human salmonellosis occurs mainly as a result of handling or consuming contaminated food products, with a small percentage of cases being related to other, less well-defined exposures, such as contact with companion animals and natural pet treats. The increasing popularity of raw food diets for companion animals is another potential pet-associated source of Salmonella organisms; however, no confirmed cases of human salmonellosis have been associated with these diets. Pets that consume contaminated pet treats and raw food diets can be colonized with Salmonella organisms without exhibiting clinical signs, making them a possible hidden source of contamination in the household. Pet owners can reduce their risk of acquiring Salmonella organisms by not feeding natural pet treats and raw food diets to their pets, whereas individuals who investigate cases of salmonellosis or interpret surveillance data should be aware of these possible sources of Salmonella organisms.

  19. Preparation and Characterization of Flame Retardant PET Fiber with Microencapsulated CMSs/PET

    Directory of Open Access Journals (Sweden)

    NIU Mei

    2016-06-01

    Full Text Available The core-shell carbon microspheres(CMSs/polyethylene terephthalate(PET capsule (PCMSs by in situ polymerization was selected as flame retardant. The flame-retardant PCMSs/PET functional fiber was prepared by melt spinning method. The structure and properties of PET fiber with different mass fractions of flame retardant were characterized by SEM, sound velocimeter, tensile tester and limit oxygen index apparatus. The results show that PCMSs has a good compatibility and dispersion within PET matrix, and the excellent moisture absorption and flame retardant properties of functional PET fiber with smooth surface is obtained when the mass fraction of PCMSs is 0.6%, but the mechanical property of PCMSs/PET fiber with 0.6% PCMSs is a little lower than the PCMSs/PET fiber with 0.2% PCMSs.

  20. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    International Nuclear Information System (INIS)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases

  1. The value of FDG-PET/CT in the post-treatment evaluation of endometrial carcinoma: a comparison of PET/CT findings with conventional imaging and CA 125 as a tumour marker.

    Science.gov (United States)

    Ozcan Kara, P; Kara, T; Kaya, B; Kara Gedik, G; Sari, O

    2012-09-01

    This retrospective study was designed to assess the value of positron emission tomography/computed tomography imaging (PET/CT) in the post-treatment evaluation of the patients with endometrial carcinoma and to compare PET/CT scan with conventional imaging (CI) including computed tomography (CT), ultrasonography (US) and magnetic resonance imaging (MRI) and CA 125 with both 20U/ml and 35U/ml cut-off values. A total of 31 patients who were treated for histopathologically proven endometrial adenocarcinoma, underwent PET/CT examination for restaging and suspected recurrence. Thirty five PET/CT studies were performed in 31 patients. Lesion status was determined on the basis of clinical follow-up including radiological imaging (follow-up CT scan) at least 6 months and response to therapy. Of the 35 PET/CT studies, 13 (37%) studies were positive, whereas 22 (63%) of them were negative. On study-based analysis the overall sensitivity, specificity, accuracy for PET/CT imaging were 100%, 96% and 97%, respectively. The corresponding information for CI were 46%, 87% and 74%, for CA 125 (cut off=20U/ml) measurement were 45%, 88% and 74%, and for CA 125 (cut off=35U/ml) measurement were 27%, 100% and 78%, respectively. On lesion-based analysis, PET/CT revealed only one false positive case. In none of 21 patients with negative 22 PET/CT studies, no subsequent clinical or radiological recurrences were observed with a follow-up of at least 6 months. FDG-PET/CT is found more useful modality than CI and CA 125 in the evaluation of post-treatment endometrial carcinoma patients, for suspected recurrence. Copyright © 2011 Elsevier España, S.L. and SEMNIM. All rights reserved.

  2. Multiparametric PET imaging in thyroid malignancy characterizing tumour heterogeneity: somatostatin receptors and glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Traub-Weidinger, Tatjana [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Putzer, Daniel; Bale, Reto [Medical University of Innsbruck, Department of Radiology, Innsbruck (Austria); Guggenberg, Elisabeth von; Dobrozemsky, Georg; Nilica, Bernhard; Kendler, Dorota; Virgolini, Irene Johanna [Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria)

    2015-12-15

    Radiolabelled somatostatin (SST) analogues have proven useful in diagnosing tumours positive for SST receptor (SSTR). As different subtypes of SSTR are expressed on the tumour cell surface, the choice of appropriate therapeutic SST analogue is crucial. We evaluated the SSTR status of thyroid cancer patients who had signs of progressive disease comparing different SSTR ligands for PET imaging to evaluate possible further therapeutic options. PET with {sup 68}Ga-radiolabelled SSTR ligands DOTA lanreotide (DOTA-LAN), DOTA-Tyr{sup 3} octreotide (DOTA-TOC) and {sup 18}F-FDG was performed in 31 patients with thyroid cancer (TC). These 31 patients comprised 18 with radioiodine non-avid differentiated TC (DTC) including 6 papillary TC (PTC), 8 follicular TC (FTC) and 4 oxyphilic TC (oxyTC), 5 with anaplastic TC (ATC), and 8 with medullary TC (MTC). The PET results were compared in a region-based evaluation. All patients underwent a PET study with {sup 68}Ga-DOTA-LAN, 28 patients with {sup 68}Ga-DOTA-TOC and 28 patients with {sup 18}F-FDG. A lack of SSTR expression was found in 13 of the 31 patients (42 %) with negative results with both SSTR tracers in 12 patients. Ambiguous results with both SSTR tracers were observed in one patient. High tracer uptake in SSTR PET images was seen in seven DTC patients (39 %; two PTC, three FTC, two oxyTC), in four ATC patients (80 %) and in six MTC patients (75 %). Lesions showing aerobic glycolysis on {sup 18}F-FDG PET were found in 24 of 28 patients (86 %) with corresponding positive results with {sup 68}Ga-DOTA-LAN in 35 % and with {sup 68}Ga-DOTA-TOC in 29 %. The heterogeneous SSTR profile of TC tumour lesions needs to be evaluated using different SSTR PET tracers to characterize more closely the SSTR subtype affinities in patients with progressive TC in order to further stratify therapy with SSTR therapeutics. (orig.)

  3. Clinical significance of pretreatment FDG PET/CT IN MOBG-avid pediatric neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seo Young; Kim, Yong Il; Cheon, Gi Jeong; Kang, Keon Wook; Chung, June Key; Lee, Dong Soo; Kang, Hyoung Jin; Shin, Hee Young [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, E. Edmund [Seoul National University, Seoul (Korea, Republic of); Rahim, Muhammad Kashif [Nishtar Medical College and Hospital, Multan (Pakistan)

    2017-06-15

    {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) imaging is well known to have clinical significance in the initial staging and response evaluation of the many kinds of neoplasms. However, its role in the pediatric neuroblastoma is not clearly defined. In the present study, the clinical significance of FDG-PET/computed tomography (CT) in 123I- or 131I-metaiodobenzylguanidine (MIBG)-avid pediatric neuroblastoma was investigated. Twenty patients with neuroblastoma who undertook pretreatment FDG PET/CT at our institute between 2008 and 2015 and showed MIBG avidity were retrospectively enrolled in the present study. Clinical information—including histopathology, and serum markers—and several PET parameters—including SUVmax of the primary lesion (Psuv), target-to-background ratio (TBR), metabolic tumor volume (MTV), and coefficient of variation (CV)—were analyzed. The prognostic effect of PET parameters was evaluated in terms of progression-free survival (PFS). Total 20 patients (4.5 ± 3.5 years) were divided as two groups by disease progression. Six patients (30.0 %) experienced disease progression and one patient (5.0 %) died during follow-up period. There were not statistically significant in age, stage, MYCN status, primary tumor size, serum lactate dehydrogenase (LDH), neuron-specific enolase (NSE), and ferritin level between two groups with progression or no progression. However, Psuv (p = 0.017), TBR (p = 0.09), MTV (p = 0.02), and CV (p = 0.036) showed significant differences between two groups. In univariate analysis, PFS was significantly associated with Psuv (p = 0.021) and TBR (p = 0.023). FDG-PET parameters were significantly related with progression of neuroblastoma. FDG-PET/CT may have the potential as a valuable modality for evaluating prognosis in the patients with MIBG-avid pediatric neuroblastoma.

  4. Survival outcomes in patients with cervical cancer after inclusion of PET/CT in staging procedures

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Henrik Villibald [University of Copenhagen, Department of Radiation Oncology, Rigshospitalet, Copenhagen (Denmark); Section for Radiotherapy, Rigshospitalet, Department of Oncology, Copenhagen (Denmark); Loft, Annika [University of Copenhagen, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Berthelsen, Anne Kiil [University of Copenhagen, Department of Radiation Oncology, Rigshospitalet, Copenhagen (Denmark); University of Copenhagen, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Christensen, Ib Jarle [University of Copenhagen, The Finsen Laboratory, Rigshospitalet, Copenhagen (Denmark); University of Copenhagen, Biotech Research and Innovation Centre (BRIC), Copenhagen (Denmark); Hoegdall, Claus [University of Copenhagen, Department of Gynecology, Rigshospitalet, Copenhagen (Denmark); Engelholm, Svend Aage [University of Copenhagen, Department of Radiation Oncology, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    In cancer of the uterine cervix, lymph node metastases are associated with a poor prognosis. Even so, the International Federation of Gynecology and Obstetrics (FIGO) does not take into account diagnostic results of methods such as PET/CT, since these are not readily available everywhere. As undetected lymph node metastases can lead to undertreatment, any difference in the underlying prevalence of false-negative scans between CT and PET/CT may be reflected in treatment outcomes. This study investigated survival outcomes in node-negative patients before and after the introduction of PET/CT. This was a single-institution retrospective analysis of 301 patients with a histopathological diagnosis of cervical cancer. The patients were receiving chemoradiotherapy with curative intent according to the standard protocol of the department for patients without lymph node metastases as assessed by pretreatment CT or PET/CT. Patients were stratified into two groups: PET/CT and non-PET/CT. Patient characteristics and treatment outcomes were acquired from the treatment database. Significant differences of 23 % (95 % CI 17 - 29 %), 19 % (95 % CI 13 - 25 %) and 12 % (95 % CI 6 - 18 %) in 5-year overall, disease-free and disease-specific survival, respectively, were observed between the two patient groups. The difference remained significant in univariate and multivariate analyses of overall survival (hazard ratio 0.61, 95 % CI 0.42 - 0.89; p = 0.010), including age, FIGO stage, performance status, BMI, and histopathology. Inclusion of PET/CT in the preradiotherapy diagnostic protocol may lead to nodal stage migration not reflected in the FIGO stage. It was found to be a significant covariate, and could lead to selection bias that needs to be taken into account when designing and reporting on clinical trials. (orig.)

  5. 7 CFR 501.10 - Pets.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Pets. 501.10 Section 501.10 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON U.S. MEAT ANIMAL RESEARCH CENTER, CLAY CENTER, NEBRASKA § 501.10 Pets. Animals shall be brought...

  6. Welfare of non-traditional pets.

    Science.gov (United States)

    Schuppli, C A; Fraser, D; Bacon, H J

    2014-04-01

    The keeping of non-traditional or 'exotic' pets has been growing in popularity worldwide. In addition to the typical welfare challenges of keeping more traditional pet species like dogs and cats, ensuring the welfare of non-traditional pets is complicated by factors such as lack of knowledge, difficulties meeting requirements in the home and where and how animals are obtained. This paper uses examples of different species to highlight three major welfare concerns: ensuring that pets under our care i) function well biologically, ii) are free from negative psychological states and able to experience normal pleasures, and iii) lead reasonably natural lives. The keeping of non-traditional pets also raises ethical concerns about whether the animal poses any danger to others (e.g. transmission of zoonotic diseases) and whether the animal might cause environmental damage (e.g. invading non-native habitats when released). The authors used these considerations to create a checklist, which identifies and organises the various concerns that may arise over keeping non-traditional species as pets. An inability to address these concerns raises questions about how to mitigate them or even whether or not certain species should be kept as pets at all. Thus, the authors propose five categories, which range from relatively unproblematic pet species to species whose keeping poses unacceptable risks to the animals, to humans, or to the environment. This approach to the evaluation and categorisation of species could provide a constructive basis for advocacy and regulatory actions.

  7. PET/MR Imaging in Vascular Disease

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Pedersen, Sune Folke; Kjær, Andreas

    2016-01-01

    For imaging of atherosclerotic disease, lumenography using computed tomography, ultrasonography, or invasive angiography is still the backbone of evaluation. However, these methods are less effective to predict the likelihood of future thromboembolic events caused by vulnerability of plaques. PET...... through data and arguments that support increased use of PET/MR imaging in atherosclerotic imaging....

  8. Evaluating College Student Interest in Pet Therapy

    Science.gov (United States)

    Adamle, Kathleen N.; Riley, Tracy A.; Carlson, Tracey

    2009-01-01

    The first year of college can be extremely stressful, especially for students residing on campus. Objective: The authors obtained information from college freshmen about their relationships with pets and investigated interest in a pet therapy program as social support for transient stressful periods. Participants: As part of a university…

  9. 36 CFR 1002.15 - Pets.

    Science.gov (United States)

    2010-07-01

    ... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired persons or hearing ear dogs accompanying hearing-impaired persons. (2) Failing to crate, cage, restrain on a leash which shall not exceed six feet in length, or otherwise physically confine a pet at all...

  10. Developing simplified Regional Potential Evapotranspiration (PET ...

    African Journals Online (AJOL)

    Regional Potential Evapotranspiration (PET) estimation method was developed to estimate the potential evapotranspiration (reference evapotranspiration) over Abbay Basin as a function of basin maximum and minimum temperature, and modulated by site specific elevation data. The method is intended to estimate PET in ...

  11. Other PET tracers for neuroendocrine tumors

    NARCIS (Netherlands)

    Koopmans, Klaas Pieter; Glaudemans, Andor W J M

    In this article the applicability of (124)I-MIBG and (11)C-5-HTP PET for the detection of abdominal gastro-enteropancreatic neuroendocrine tumors is discussed. (124)I-MIBG is a positron-emitting variant of (123)I-MIBG and therefore suited for PET imaging. Due to the better intrinsic characteristics

  12. PET-container collection systems in Europe

    NARCIS (Netherlands)

    Logtenberg, T.; Groot, J.L.B. de; Rink, T.

    1996-01-01

    This report presents the results of a TNO study of the present situation in Europe with regard to PET-bottle recycling. The overview concentrates on the main PET-bottles consuming countries in Europe i.e.: France, Italy, Spain and the UK. In addition the system in Belgium is presented. Applying a

  13. Positron emission tomography (PET) in endocrine tumours ...

    African Journals Online (AJOL)

    Commonly used PET radionuclides include fluorine-18, carbon-11, nitrogen- 13 and oxygen-15, which are commonly found in organic chemistry and biochemistry. Undoubtedly the ... In parathyroid adenoma, FDG PET appears useful in cases where conventional nuclear medicine imaging is negative. For adrenal masses ...

  14. Radiation Protection in PET-CT

    International Nuclear Information System (INIS)

    2011-10-01

    The presentation is based on the following areas: radiological monitoring installations in the production of PET radiopharmaceuticals, personal dose, dosage advertising, nuclear medicine, PET, radiation protection of patients, requirements for medical practice, regulatory aspects, dose calculation, shields, quantities, center Cudim, cyclotron and synthesis of radiopharmaceuticals, biological effects of radiation protection practices.

  15. Salmonella infection acquired from reptilian pets.

    Science.gov (United States)

    Sanyal, D; Douglas, T; Roberts, R

    1997-10-01

    Two children presented with signs and symptoms of gastroenteritis. Salmonella chameleon was isolated from the stool of one child and also from an iguana kept in the home as a pet. Salmonella arizonae was isolated from the stool of the other child and also from four snakes sharing the same household. Exotic reptiles are unsuitable pets to share the home environment with infants.

  16. PET scan as a functional diagnostic tool

    International Nuclear Information System (INIS)

    Kyogoku, Shinsuke; Ogawa, Shoichi; Amano, Maki

    2007-01-01

    Morphological diagnostic imaging, such as computed tomography (CT) and magnetic resonance imaging (MRI) have undergone rapid development of hardware and imaging technique. However, these imaging modalities have some limitations in determining whether lymph node swelling is malignant or benign. It is difficult for the radiologist and physician to differentiate malignant lesion from benign lesion based solely on lymph node size. Mass media has sensationalized the efficacy of positron emission tomography (PET) scan. PET scans have now become a well-known medical examination among the general public. The ministry of health, labor and welfare approved F-18 fluorodeoxyglucose (FDG) as a commercially available isotope in 2005 and PET centers have rapidly spread in Japan. PET scan is considered a breakthrough in cancer detection, as a functional diagnostic tool. This article discusses simple methods and isotopes for PET scan and the diseases for which FDG-PET scan is covered by the medical insurance system. The preparation and workflow of FDG-PET examination are also discussed. Finally, I describe the usefulness of FDG-PET scan using an illustrative case presentation. (author)

  17. FDG-PET/CT in autosomal dominant polycystic kidney disease patients with suspected cyst infection.

    Science.gov (United States)

    Pijl, Jordy Pieter; Glaudemans, Andor W J M; Slart, Riemer H J A; Kwee, Thomas Christian

    2018-04-13

    Purpose: To determine the value of 18 F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) for diagnosing renal or hepatic cyst infection in patients with autosomal dominant polycystic kidney disease (ADPKD). Methods: This retrospective single-center study included all patients with ADPKD who underwent FDG-PET/CT because of suspected cyst infection between 2010 and 2017. Results: Thirty FDG-PET/CT scans of thirty individual patients were included, of which 19 were positive for cyst infection. According to a previously established clinical and biochemical reference standard, FDG-PET/CT achieved sensitivity of 88.9%, specificity of 75.0%, positive predictive value of 84.2%, and negative predictive value of 81.8% for the diagnosis of cyst infection. In 5 cases, FDG-PET/CT suggested a different pathologic process that explained the symptoms, including pneumonia ( n = 1), generalized peritonitis ( n = 1), pancreatitis ( n = 1), colitis ( n = 1), and cholangitis ( n = 1). Total duration of hospital stay and duration between FDG-PET/CT scan and hospital discharge of patients with an FDG-PET/CT scan positive for cyst infection were significantly longer than those with a negative scan ( P = 0.005 and P = 0.009, respectively). Creatinine levels were significantly higher in patients with an FDG-PET/CT scan positive for cyst infection than in patients with a negative scan ( P = 0.015). Other comparisons of clinical parameters (age, gender, presence of fever (>38.5°C) for more than 3 days, abdominal pain, history of solid organ transplantation and nephrectomy, immune status), laboratory values (C-reactive protein level (CRP), leukocyte count, estimated glomerular filtration rate), and microbiologic results (blood and urine cultures) were not significantly different ( P = 0.13-1.00) between FDG-PET/CT-positive and -negative patients. Conclusion: FDG-PET/CT is a useful and recommendable (upfront) imaging modality for the evaluation of

  18. Application of PET and PET/CT imaging for cancer screening

    International Nuclear Information System (INIS)

    Chen Yenkung; Hu Fenglan; Shen Yehyou; Liao, A.C.; Hung, T.Z.; Su, Chentau; Chen Liangkuang

    2004-01-01

    The aim of this study was to evaluate the potential application of 18F-fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) and PET/CT for cancer screening in asymptomatic individuals. Methods: The subjects consisted of 3631 physical check up examinees (1947 men, 1684 women; mean age ±SD, 52.1±8.2 y) with non-specific medical histories. Whole-body FDG PET (or PET/CT), ultrasound and tumor markers were performed on all patients. Focal hypermetabolic areas with intensities equal to or exceeding the level of FDG uptake in the brain and bladder were considered abnormal and interpreted as neoplasia. Follow-up periods were longer than one year. Results: Among the 3631 FDG PET (including 1687 PET/CT), ultrasound and tumor markers examinations, malignant tumors were discovered in 47 examinees (1.29%). PET findings were true-positive in 38 of the 47 cancers (80.9%). In addition, 32 of the 47 cancers were performed with the PET-CT scan. PET detected cancer lesions in 28 of the 32 examinees. However, the CT detected cancer lesions in only 15 of 32 examinees. Conclusion: The sensitivity of FDG PET in the detection of a wide variety of cancers is high. Most cancer can be detected with FDG PET in a resectable stage. CT of the PET/CT for localization and characteristics of the lesion shows an increased specificity of the PET scan. Using ultrasound and tumor markers may complement the PET scan in cancer screening for hepatic and urologic neoplasms. (authors)

  19. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  20. PET-CT in endocrinology

    International Nuclear Information System (INIS)

    Parysow, O.; Jager, V.; Racioppi, S.; Mollerach, A.M.; Collaud, C.; Arma, I.

    2008-01-01

    PET/CT scans have reached an important place in the evaluation of endocrine tumors. The metabolic marker 18F-FDG is the most widespread over the world, and, for the time being, it is the only one available in our country. The limitations of this technique in Endocrinology include high differentiation and low aggressiveness of most endocrine tumors, and low detection rate for low cellularity and/or small lesions. Indications for PET/CT scan in these tumors should be precise, due to the fact that not all of these lesions are significantly glucose-avid and to extract the maximum diagnostic efficacy of this modality to achieve the optimum diagnostic accuracy. The most important indication is DTC with high Tg levels and negative 131-Iodine scans. It is advisable to indicate a PET/CT scan in patients with Tg > 10 ng/ml and stimulated TSH (endogenous or exogenous). The aim is to locate recurrences and metastases in order to remove them, either surgically or by any other therapy alternative to 131 I. Due to higher uptake in more aggressive lesions, this study has a high prognostic value. In patients with high Tg levels, negative 131 I scan, and abnormal FDG uptake, the practitioner must act more aggressively in order to remove the pathologic foci, while with a negative FDG -PET scan, the conduct can be expectant, with periodic follow-up. The introduction of other positron-emitting tracers like 124-Iodine, is likely to yield superior quality images and provide better diagnoses. FDG has a limited efficiency in neuroendocrine tumors, unless they show a significant level of dedifferentiation. The scan is indicated in MTC, when calcitonin levels are above 1000 pg/ml, in order to locate the tumor sites. With the introduction of more specific positron-emitting radiopharmaceuticals, such as 18F-DOPA, 68Ga DOTA, 11C methomidate, 11C-hydroxytryptophan and others, it will be possible to study the metabolic-molecular behavior of these tumors with a more accurate approach. (author) [es

  1. PET scan and radiation protection

    International Nuclear Information System (INIS)

    Montoya, F.; Lahmi, A.; Rousseau, A.

    2006-01-01

    The purpose was the optimization of the radiation protection during examinations with 18 F-FDG, The immediate validation by the D.G.S.N.R., the results of dosimetry (h.p.10 = 12 μ sievert (average value/ technician / day for 6 patients) demonstrate the efficiency of the implemented means. From the very beginning, the installation of a PET-scanner requires a multidisciplinary conception. This essential thought contributes to an optimal radiation protection of the entire personnel of the service. (N.C.)

  2. PET after use. From problem to opportunity

    International Nuclear Information System (INIS)

    Chiacchio, G.; Malinconico, M.; Santacesaria, E.; Di Sero, M.

    1999-01-01

    Due to collection, separation and legislation problems, the only type of PET suitable for recycling, is, at moment, the polymer employed in liquid containers or, more precisely, PET from drink bottles. The paper refer to the most up-to-date strategies to overcomes typical problems occurring during physical recycling of PET (hydrolytic and thermal degradation). Among others, a recent procedure is cited, that utilizes p-hydroxybenzoic acid and titanium tetraisopropylate. As far as chemical recycling is concerned, alternative methodologies to PET glycolysis (normally employing ethyleneglycol to obtain monomers) using unsaturated diols to obtain polyesters suitable for production of thermosetting resins, are reported. Finally, chemical recycling of PET to produce alkyl-phthalates (well know plasticizers for thermoplastic polymers) is described [it

  3. FDG PET/CT in cancer

    DEFF Research Database (Denmark)

    Petersen, Henrik; Holdgaard, Paw Christian; Madsen, Poul Henning

    2016-01-01

    PURPOSE: The Region of Southern Denmark (RSD), covering 1.2 of Denmark's 5.6 million inhabitants, established a task force to (1) retrieve literature evidence for the clinical use of positron emission tomography (PET)/CT and provide consequent recommendations and further to (2) compare the actual...... use of PET/CT in the RSD with these recommendations. This article summarizes the results. METHODS: A Work Group appointed a professional Subgroup which made Clinician Groups conduct literature reviews on six selected cancers responsible for 5,768 (62.6 %) of 9,213 PET/CT scans in the RSD in 2012...... and rated with regard to strength and evidence level. Consequent recommendations for applications of PET/CT were established. The actual use of PET/CT was compared with these, where grades A and B indicated "established" and "useful" and grades C and D "potentially useful" and "non...

  4. Towards enhanced PET quantification in clinical oncology

    DEFF Research Database (Denmark)

    Zaidi, Habib; Karakatsanis, Nicolas

    2018-01-01

    Positron emission tomography (PET) has, since its inception, established itself as the imaging modality of choice for the in vivo quantitative assessment of molecular targets in a wide range of biochemical processes underlying tumour physiology. PET image quantification enables to ascertain...... a direct link between the time-varying activity concentration in organs/tissues and the fundamental parameters portraying the biological processes at the cellular level being assessed. However, the quantitative potential of PET may be affected by a number of factors related to physical effects, hardware...... and software system specifications, tracer kinetics, motion, scan protocol design and limitations in current image-derived PET metrics. Given the relatively large number of PET metrics reported in the literature, the selection of the best metric for fulfilling a specific task in a particular application...

  5. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  6. The effectiveness of PET for the distinction of perirectal lymph node metastasis of rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Dae Yong; Choi, Chang Woon

    1999-12-01

    If the effectiveness for the distinction of perirectal lymph node metastasis is proved to be higher than the previous conventional detection methods, likewise CT and endorectal ultrasound, more precise and more specific information will be taken by this new modality. Preoperative biopsy-proven rectal adenocarcinoma patients with or without distant metastasis were included for this study. For the effectiveness of PET for the distinction of perirectal lymph node metastasis, CT and endorectal ultrasound versus findings of perirectal lymph node status were compared with permanent pathology results. The findings of preoperative conventional methods showed that 8 patients had not preirectal lymph node metastasis and 6 patients and perirectal lymph node metastasis. The accuracy of conventional methods was 50 % compared with 37.5 % of that of PET in the case of 8 patients. In the case of 6 patients, accuracy was 100 % in the conventional methods and 66.7 % in PET study. Overall sensitivity and specificity were 60 % and 100 % in the conventional methods and 40 % and 75 % in PET study respectively. Therefore, PET is not effective for the distinction of L/N metastasis of rectal cancer comparing with conventional methods such as CT and ERUS preoperatively.

  7. The effectiveness of PET for the distinction of perirectal lymph node metastasis of rectal cancer

    International Nuclear Information System (INIS)

    Hwang, Dae Yong; Choi, Chang Woon

    1999-12-01

    If the effectiveness for the distinction of perirectal lymph node metastasis is proved to be higher than the previous conventional detection methods, likewise CT and endorectal ultrasound, more precise and more specific information will be taken by this new modality. Preoperative biopsy-proven rectal adenocarcinoma patients with or without distant metastasis were included for this study. For the effectiveness of PET for the distinction of perirectal lymph node metastasis, CT and endorectal ultrasound versus findings of perirectal lymph node status were compared with permanent pathology results. The findings of preoperative conventional methods showed that 8 patients had not preirectal lymph node metastasis and 6 patients and perirectal lymph node metastasis. The accuracy of conventional methods was 50 % compared with 37.5 % of that of PET in the case of 8 patients. In the case of 6 patients, accuracy was 100 % in the conventional methods and 66.7 % in PET study. Overall sensitivity and specificity were 60 % and 100 % in the conventional methods and 40 % and 75 % in PET study respectively. Therefore, PET is not effective for the distinction of L/N metastasis of rectal cancer comparing with conventional methods such as CT and ERUS preoperatively

  8. Multifocal Head and Neck Paraganglioma Evaluated with Different PET Tracers: Comparison Between Fluorine-18-Fluorodeoxyglucose Between Fluorine-18-Fluorodeoxyglucose and Gallium-68-Somatostatin Receptor PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Castaldi, Paola; Rufini, Vittoria [Catholic Univ. of the Sacred Heart, Rome (Italy); Treglia, G. [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland)

    2013-09-15

    uptake in the pituitary is also evident (blue arrow). The patient refused surgery and, based on somatostatin receptor PET/CT findings, she underwent therapy with somatostatin analogues. Paragangliomas are rare neuroendocrine tumours arising anywhere along the paraganglial system, with a high frequency of hereditary forms or multifocal disease. Functional imaging with different PET tracers (including F-18-FDG to study the glucose metabolism, F-18-DOPA to study the dopaminergic metabolism and Ga-68-somatostatin analogues to study the somatostatin receptors expression) in combination with morphological imaging may be required to assess the extent of the disease in extra-adrenal paragangliomas. Recent data indicate that the choice of PET tracer should be tailored according to the tumour localisation and the genetic status. Recently, Timmers et al., evaluating a large series of patients with paraganglioma, demonstrated that F-18-FDG-PET/CT is suitable for routine functional imaging of this tumour, particularly in patients with SDH-related tumours. F-18-FDG-PET/CT has the potential to be useful in paraganglioma imaging, not only for detection of metastases but also as a prognostic tool identifying tumours with a high metabolic rate and high metastatic potential. On the other hand, recent studies demonstrated that Ga-68-somatostatin analogue PET/CT is an accurate functional imaging method in patients with neuroendocrine tumours, including those with head and neck paraganglioma. This imaging technique non-invasively provides data on receptor expression on neuroendocrine tumour cells with direct therapeutic implications, identifying those patients who are eligible for a treatment with somatostatin analogues. F-18-DOPA is another PET tracer which has been particularly useful in patients with head and neck paraganglioma. To date, significant studies comparing F-18-DOPA and Ga-68-somatostatin receptor PET/CT in this setting are still lacking. In our case, Ga-68-somatostatin receptor

  9. The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.

    Science.gov (United States)

    Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu

    2008-12-01

    The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.

  10. Microfluidic technology for PET radiochemistry

    International Nuclear Information System (INIS)

    Gillies, J.M.; Prenant, C.; Chimon, G.N.; Smethurst, G.J.; Dekker, B.A.; Zweit, J.

    2006-01-01

    This paper describes the first application of a microfabricated reaction system to positron emission tomography (PET) radiochemistry. We have applied microfluidic technology to synthesise PET radiopharmaceuticals using 18 F and 124 I as labels for fluorodeoxyglucose (FDG) and Annexin-V, respectively. These reactions involved established methods of nucleophilic substitution on a mannose triflate precursor and direct iodination of the protein using iodogen as an oxidant. This has demonstrated a proof of principle of using microfluidic technology to radiochemical reactions involving low and high molecular weight compounds. Using microfluidic reactions, [ 18 F]FDG was synthesised with a 50% incorporation of the available F-18 radioactivity in a very short time of 4 s. The radiolabelling efficiency of 124 I Annexin-V was 40% after 1 min reaction time. Chromatographic analysis showed that such reaction yields are comparable to conventional methods, but in a much shorter time. The yields can be further improved with more optimisation of the microfluidic device itself and its fluid mixing profiles. This demonstrates the potential for this technology to have an impact on rapid and simpler radiopharmaceutical synthesis using short and medium half-life radionuclides

  11. The spatial distribution of pet dogs and pet cats on the island of Ireland.

    Science.gov (United States)

    Downes, Martin J; Clegg, Tracy A; Collins, Daniel M; McGrath, Guy; More, Simon J

    2011-06-10

    There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care.

  12. The spatial distribution of pet dogs and pet cats on the island of Ireland

    Science.gov (United States)

    2011-01-01

    Background There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. Results In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. Conclusions The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care. PMID:21663606

  13. The spatial distribution of pet dogs and pet cats on the island of Ireland

    Directory of Open Access Journals (Sweden)

    More Simon J

    2011-06-01

    Full Text Available Abstract Background There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. Results In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. Conclusions The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care.

  14. Experience of Dual Time Point Brain F-18 FDG PET/CT Imaging in Patients with Infections Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Weung; Kim, Chang Guhn; Park, Soon Ah; Jung, Sang Ah [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2010-06-15

    Dual time point FDG PET imaging (DTPI) has been considered helpful for discrimination of benign and malignant disease, and staging lymph node status in patients with pulmonary malignancy. However, DTPI for benign disease has been rarely reported, and it may show a better description of metabolic status and extent of benign infection disease than early imaging only. The authors report on the use F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) imaging with additional delayed imaging on a 52-year-old man with sparganosis and a 70-year-old man with tuberculous meningitis. To the best of our knowledge, this is the first report on dual time point PET/CT imaging in patients with cerebral sparganosis and tuberculous meningitis.

  15. Prognostic meaning of neutrophil to lymphocyte ratio (NLR) and lymphocyte to monocyte ration (LMR) in newly diagnosed Hodgkin lymphoma patients treated upfront with a PET-2 based strategy.

    Science.gov (United States)

    Romano, Alessandra; Parrinello, Nunziatina Laura; Vetro, Calogero; Chiarenza, Annalisa; Cerchione, Claudio; Ippolito, Massimo; Palumbo, Giuseppe Alberto; Di Raimondo, Francesco

    2018-06-01

    Recent reports identify NLR (the ratio between absolute neutrophils counts, ANC, and absolute lymphocyte count, ALC), as predictor of progression-free survival (PFS) and overall survival (OS) in cancer patients. We retrospectively tested NLR and LMR (the ratio between absolute lymphocyte and monocyte counts) in newly diagnosed Hodgkin lymphoma (HL) patients treated upfront with a PET-2 risk-adapted strategy. NLR and LMR were calculated using records obtained from the complete blood count (CBC) from 180 newly diagnosed HL patients. PFS was evaluated accordingly to Kaplan-Meier method. Higher NLR was associated to advanced stage, increased absolute counts of neutrophils and reduced count of lymphocytes, and markers of systemic inflammation. After a median follow-up of 68 months, PFS at 60 months was 86.6% versus 70.1%, respectively, in patients with NLR ≥ 6 or NLR PET-2 scan (p PET-2 was an independent predictor of PFS in multivariate analysis. Advanced-stage patients (N = 119) were treated according to a PET-2 risk-adapted protocol, with an early switch to BEACOPP regimen in case of PET-2 positivity. Despite this strategy, patients with positive PET-2 still had an inferior outcome, with PFS at 60 months of 84.7% versus 40.1% (negative and positive PET-2 patients, respectively, p PET-2 status and to a lesser extend NLR in advanced stage, while LMR maintained its significance in early stage. By focusing on PET-2 negative patients, we found that patients with NLR ≥ 6.0 or LMR PET-2 scan, NLR and LMR can result in a meaningful prognostic system that needs to be further validated in prospective series including patients treated upfront with PET-2 adapted-risk therapy.

  16. Positron Emission Tomography - Computed Tomography (PET/CT)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) ... Emission Tomography – Computed Tomography (PET/CT)? What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, ...

  17. Demographics and husbandry of pet cats living in Sydney, Australia: results of cross-sectional survey of pet ownership.

    Science.gov (United States)

    Toribio, Jenny-Ann L M; Norris, Jacqueline M; White, Joanna D; Dhand, Nanveet K; Hamilton, Samuel A; Malik, Richard

    2009-06-01

    Our aim was to collect baseline data on the age, gender, breed, reproductive status and husbandry (housing, diet, vaccination, veterinary attention) of pet cats living in Sydney. Accordingly, a cross-sectional survey of 2768 households was conducted using a postal questionnaire. The 2006 Sydney residential phone book was used as the sampling frame. Non-responders were re-mailed the questionnaire on two further occasions, 2 and 4 weeks after the first posting. Completed questionnaires were received from 884 households. No pets were kept by 387 (43.8%) respondents. Dogs and cats were owned by 295 (33.4%) and 198 (22.5%) of households, respectively, with 7.8% of households having both cat(s) and dog(s). Fish and birds were the next most popular pets. Of the 198 cat-owning households, 54.0% kept only cat(s), while 46.5% kept cats with other pets. The distribution of cat ownership across Sydney was non-uniform. Each cat-owning household kept 1.3 cats on average, with the majority keeping one (75.8% households) or two (18.7%). For the 260 cats, the mean age was 7.1 years, the median 6 years, with a range of 3 months to 22 years. There were significantly more female (143; 55%) than male cats (117; 45%). Only seven cats (2.7%) were sexually entire, and these were all pet park enclosures'. Pedigree cats were significantly more likely than crossbreds to be housed indoors. Most owners fed their cats a combination of commercial dry and canned food (38.1%), although fresh meat was popular also and either fed alone (1.6%) or in combination with dry food (14.4%), tinned food (1.6%) or canned and dry food (25.8%). A diet consisting of dry food alone was fed to cats in 13.4% of households. Ninety percent of cats had been vaccinated at least once, while 72.2% received a vaccination in the last 3 years. Older cats were less likely to have been vaccinated recently than younger cats. Only 5.8% of cats had never visited a veterinarian. For the 243 cats that had received veterinary

  18. Postapplication Fipronil Exposure Following Use on Pets.

    Science.gov (United States)

    Cochran, R C; Yu, Liu; Krieger, R I; Ross, J H

    2015-01-01

    Fipronil is a pyrazole acaricide and insecticide that may be used for insect, tick, lice, and mite control on pets. Residents' short-term and long-term postapplication exposures to fipronil, including secondary environmental exposures, were estimated using data from chemical-specific studies. Estimations of acute (24-h) absorbed doses for residents were based on U.S. Environmental Protection Agency (U.S. EPA) 2012 standard operating procedures (SOPs) for postapplication exposure. Chronic exposures were not estimated for residential use, as continuous, long-term application activities were unlikely to occur. Estimated acute postapplication absorbed doses were as high as 0.56 μg/kg-d for toddlers (1-2 yr) in households with treated pets based on current U.S. EPA SOPs. Acute toddler exposures estimated here were fivefold larger in comparison to adults. Secondary exposure from the household environment in which a treated pet lives that is not from contacting the pet, but from contacting the house interior to which pet residues were transferred, was estimated based on monitoring socks worn by pet owners. These secondary exposures were more than an order of magnitude lower than those estimated from contacting the pet and thus may be considered negligible.

  19. Compensation for photon attenuation in PET

    International Nuclear Information System (INIS)

    Chintu Chen; Ordonez, C.E.; Xiaolin Yu.

    1992-01-01

    CT/MR and PET images usually are not in registration spatially because of differences in the imaging setup. CT, MR and PET imaging parameters that are used regularly for brain studies in their institution are compared, in addition, because the patient orientations in CT/MR and PET scanners are not the same, slice centers are positioned differently relative to the patients anatomy. For application of the new idea of using structural information from CT or MR images in PET image reconstruction for attenuation correction, image registration is required as a first step so that one can obtain a corresponding anatomic map for any selected PET image plane. The authors chose to use the surface-matching technique developed in their laboratories for image registration because this method is retrospective and accurate. After the PET and CT/MR scans are registered, they reslice the CT/MR images along the planes of the PET images. The differences in slice thickness and slice separation, as well as in image resolution between various image modalities are to be considered

  20. Attenuation correction for small animal PET tomographs

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Patrick L [David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095 (United States); Rannou, Fernando R [Departamento de Ingenieria Informatica, Universidad de Santiago de Chile (USACH), Av. Ecuador 3659, Santiago (Chile); Chatziioannou, Arion F [David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095 (United States)

    2005-04-21

    Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-sized and one rat-sized) and two animal subjects (one mouse and one rat) were scanned in CTI Concorde Microsystem's microPET (registered) Focus{sup TM} for emission and transmission data and in ImTek's MicroCAT{sup TM} II for transmission data. PET emission image values were calibrated against a scintillation well counter. Results indicate that the scale factor method of attenuation correction places the average measured activity concentration about the expected value, without correcting for the cupping artefact from attenuation. Noise analysis in the phantom studies with the PET-based method shows that noise in the transmission data increases the noise in the corrected emission data. The CT-based method was accurate and delivered low-noise images suitable for both PET data correction and PET tracer localization.

  1. Comparing life cycle energy and GHG emissions of bio-based PET, recycled PET, PLA and man-made cellulosics

    NARCIS (Netherlands)

    Shen, L.; Worrell, E.; Patel, M.K.

    2012-01-01

    The purpose of this paper is to review the environmental profiles of petrochemical PET, (partially) bio-based PET, recycled PET, and recycled (partially) bio-based PET, and compare them with other bio-based materials, namely PLA (polylactic acid, a bio-based polyester) and man-made cellulose

  2. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  3. Practical use and implementation of PET in children in a hospital PET centre

    DEFF Research Database (Denmark)

    Borgwardt, Lise; Larsen, Helle Jung; Pedersen, Kate

    2003-01-01

    Children are not just small adults-they differ in their psychology, normal physiology and pathophysiology, and various aspects should be considered when planning a positron emission tomography (PET) scan in a child. PET in children is a growing area, and this article describes the practical use...... and implementation of PET in children in a hospital PET centre. It is intended to be of use to nuclear medicine departments implementing or starting to implement PET scans in children. Topics covered are: dealing with children, dosimetry, organisation within the department and relations with other departments......, preparation of the child (provision of information to the child and parents and the fasting procedure), the imaging procedure (resting, tracer injection, positioning, sedation and bladder emptying) and pitfalls in the interpretation of PET scans in children, including experiences with telemedicine....

  4. Evaluating pet foods: how confident are you when you recommend a commercial pet food?

    Science.gov (United States)

    Zicker, Steven C

    2008-08-01

    The safety, adequacy, and efficacy of pet foods are important considerations for veterinarians and consumers. Manufacturers of pet foods in the United States are required to comply with multiple regulations from a variety of governmental and state agencies to market foods in the public sector. However, consumers and veterinarians may not be aware of the multiple systems in place that help ensure the safety and adequacy of foods for their pets. Since the veterinarian occupies a key role to make recommendations to consumers regarding pet foods, it is the purpose of this article to review the processes of pet food manufacturing, as well as the processes that have been developed to help ensure safety and adequacy of pet foods in the United States.

  5. How much can a negative FDG-PET be trusted?

    International Nuclear Information System (INIS)

    Wang Shuxia

    2004-01-01

    Purpose: False-negative FDG-PET constituted 22.7% of all clinically identified negative PET in a ten year retrospective review about FDG-PET on irradiated brain tumour. Uncovering possible influencing factors of false-negative FDG-PET may have significant value. Material and methods: 10 patients with a first negative and then a second positive PET during very short time separation and 6 patients with surgically confirmed false-negative PET were traced. Histological type, irradiation parameter, steroids effect were discussed. To define temporary irradiation effect on FDG uptake, interval between radiation treatment to PET examination of these two groups were compared with 24 surgically confirmed true-positive PET, 5 surgically confirmed true-negative PET Results: 80% negative-positive PET transformation happened within 31 weeks. No statistically significant difference with regard to time from irradiation could be found between groups. Steroids medication closely before PET examination was about the same before the first negative and second positive PET scan. 5/6 surgically confirmed false-negative PET patients did not take steroids before PET examination. Conclusion: Tumour histology type, temporary irradiation effect and steroids medication did not constitute the reasons for false negative PET in our patient series. PET could not identify tumour relapse in the very early stage. Therefore, if clinically indicated, second FDG-PET might be a better selection to pick up tumour relapse instead of exploratory surgery or biopsy. In that case, the suitable time point for the second PET could be within 31 weeks after the first PET examination. Keywords: false-negative, FDG-PET, influencing factor, irradiation effect, steroids. (author)

  6. Pet Ownership and Evacuation Prior to Hurricane Irene

    OpenAIRE

    Nick Rohrbaugh; Kelsey Bogue; Melissa G. Hunt

    2012-01-01

    Simple Summary Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones during the 2011 Hurricane Irene were surveyed about whether or not they evacuated and about their experiences during the hurricane. Although pet-ownership was not statistically associated with evacuation failure, many pet owners who chose not to evacuate still claimed that they did not evacuate because of difficulties with evacuating their pet. These findings suggest that more work needs to be done ...

  7. The heritage of radiotracers for PET

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1988-01-01

    The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology. 54 refs

  8. Uncertainces in tumor target definition using PET

    International Nuclear Information System (INIS)

    Kirov, A.

    2013-01-01

    Full text: Introduction: PET entered into the clinics for radiation therapy as a means of displaying the metabolically active part of the tumor. However this advantage, PET has a number of shortcomings that prevent its use for precise determination of the tumor boundaries. What you will learn: The aim of the lecture is to present: the requirements for the accuracy of the determination of tumor boundaries in radiation therapy; the main phenomena which bring uncertainty using PET and a brief overview of methods for segmentation of tumors and their problems

  9. Properties of tribology for Si implanted PET

    International Nuclear Information System (INIS)

    Wu Yuguang; Zhang Tonghe; Zhang Xu; Liu Andong; Xie Mengxia; Zhang Aimin; Chen Jianmin

    2002-01-01

    Polyethylene terephthalate (PET) has been modified with Si ions from a metal vapor arc source (MEVVA). After implantation, the surface structure has been greatly changed. The experimental results of infrared absorption indicated that the particles are referred to rich carbon and SiC particles. The PET has been strengthened by these dispersed particles. The measurement results using nanometer hardness tester reveal that both surface hardness and modulus increase obviously. Therefore the surface wear resistance improved extremely. Finally the modification mechanism of Si implanted PET was discussed

  10. The Heritage of Radiotracers for PET

    Science.gov (United States)

    Fowler, J. S.; Wolf, A. P.

    1988-05-01

    The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology.

  11. The spatial distribution of pet dogs and pet cats on the island of Ireland

    OpenAIRE

    Downes, Martin J.; Clegg, Tracy A.; Collins, Daniel M.; et al.

    2011-01-01

    Abstract Background There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This...

  12. PET/CT and PET/MRI in head and neck malignancy.

    Science.gov (United States)

    Szyszko, T A; Cook, G J R

    2018-01-01

    Combined 2-[ 18 F]-fluoro-2-deoxy-d-glucose (FDG) positron-emission tomography (PET)/computed tomography (CT) has an established role in the staging of difficult cases of head and neck (HN) squamous cell carcinoma (SCC), looking for an unknown primary, assessing response post-chemotherapy at 3-6 months, and differentiating relapse from treatment effects in patients suspected to have tumour recurrence. The PET NECK trial, comparing PET/CT surveillance versus neck dissection in advanced head and neck cancer showed survival was similar among patients who underwent PET/CT-guided surveillance and those who underwent planned neck dissection, but surveillance was more cost-effective. There is growing interest in the use of hypoxia PET tracers, especially in targeting radiotherapy, where the radiotherapy dose can be boosted in regions of hypoxia; the use of 68 Ga peptide tracers in neuroendocrine malignancy and also in the growing field of combined PET/magnetic resonance imaging (MRI). PET/MRI has the advantage of increased anatomical detail and radiation dose reduction combined with the molecular and metabolic data from PET, although PET/CT has the advantage in better sensitivity for imaging lung metastases. Thus far, there is good agreement between PET/CT and PET/MRI with high correlation between semi-quantitative measurements in primary, nodal, osseous, and soft-tissue lesions imaging. PET/MRI may indeed provide greater accuracy than the currently available imaging procedures in the staging and later treatment response evaluation in HNSCC. Copyright © 2017. Published by Elsevier Ltd.

  13. PET and PET-CT. State of the art and future prospects

    International Nuclear Information System (INIS)

    Fanti, Stefano; Franchi, Roberto; Battista, Giuseppe; Monetti, Nino; Canini, Romeo

    2005-01-01

    Fluoro-deoxyglucose positron emission tomography (FDG PET) enables the in vivo study of tissue metabolism, and thus is able to identify malignant tumours as hypermetabolic lesions by an increase in tracer uptake. Many papers have demonstrated both the relevant impact of FDG PET on staging of many cancers and the superior accuracy of the technique compared with conventional diagnostic methods for pre-treatment evaluation, therapy response evaluation and relapse identification. In particular PET was found useful in identifying lymph nodal and metastatic spread. thus altering patient management in more than 30% of cases. PET images, however, provide limited anatomical data, which in regions such as the head and neck, mediastinum and pelvic cavity is a significant drawback. The exact localization of lesions may also be difficult in some cases, on the basis of PET images alone. The introduction of combined PET-computed tomography (PET-CT) scanners enables the almost simultaneous acquisition of transmission and emission images, thus obtaining optimal fusion images in a very short time. PET-CT fusion images enable lesions to be located, reducing false positive studies and increasing accuracy; the overall duration of examination may also be reduced. On the basis of both literature data and our experience we established the clinical indications when PET-CT may be particularly useful, in comparison with PET alone. It should also be underlined that the use of PET-CT is almost mandatory for new traces such as C-choline and C-methionine; these new tracers may be applied for studying tumours not assessable with FDG, such as prostate cancer. In conclusion PET-CT is at present the most advanced method for metabolic imaging, and is capable of precisely localizing and assessing tumours; fusion images reduce false positive and inconclusive studies, thus increasing diagnostic accuracy [it

  14. Erythropoietic protoporphyria and pretransplantation treatment with nonbiological liver assist devices

    DEFF Research Database (Denmark)

    Eefsen, Martin; Rasmussen, Allan; Wulf, Hans Christian

    2007-01-01

    of patients liver failure is a significant complication and liver transplantation is the only treatment option. Damage to both abdominal skin and organs occurs when exposed to operating light; however, this problem can be ameliorated by the use of filters that block the transmission of light with wavelength...... below 470 nm. A more unusual but very serious complication postoperatively is severe motor neuropathy, with few or no known acute available precautions. An effective treatment option is needed to manage EPP crises and to prevent complications after liver transplantation. We successfully treated...... a patient with EPP-induced liver failure with the molecular adsorbents recirculating system (MARS) and Prometheus in independent sessions. Following treatment with MARS we found a 9.1% reduction of the RBC-PPIX concentration and a 5.9% reduction after treatment with the Prometheus system. Plasmapheresis...

  15. Not Just "A Walking the Dog": Dog Walking and Pet Play and Their Association With Recommended Physical Activity Among Adolescents.

    Science.gov (United States)

    Martin, Karen E; Wood, Lisa; Christian, Hayley; Trapp, Georgina S A

    2015-01-01

    To examine the role of pet play and dog walking in children's and adolescents' leisure time, and the relationship between these activities and physical activity. The study design was observational. The study setting was metropolitan Perth and nonmetropolitan regions in Western Australia. The study included 1097 primary school (mean age, 10.1 years; SD, 1.6 years) and 657 secondary school (mean age, 14.0 years; SD, 1.3 years) students. Validated measures of total physical activity, dog walking, and pet play activity (prevalence and time) were calculated. Generalized linear models tested for differences between proportions, while adjusting for socioeconomic status, age, and school-level clustering. Approximately one third of primary school and one quarter of secondary school students reported that they walked the dog at least once in the last week. Pet play was the most common play activity for primary and secondary school girls, and the second and third most popular play activity for secondary and primary school boys, respectively. Secondary school students who walked the dog or played with pets spent an average of 1 hour per week on each activity, and they were significantly more likely (p dog walking and pet play, and the high level of pet ownership in many Western countries, promotion of these activities to support young people's health is warranted.

  16. Molecular Imaging Challenges With PET

    CERN Document Server

    Lecoq, P

    2010-01-01

    The future trends in molecular imaging and associated challenges for in-vivo functional imaging are illustrated on the basis of a few examples, such as atherosclerosis vulnerable plaques imaging or stem cells tracking. A set of parameters are derived to define the specifications of a new generation of in-vivo imaging devices in terms of sensitivity, spatial resolution and signal-to-noise ratio. The limitations of strategies used in present PET scanners are discussed and new approaches are proposed taking advantage of recent progress on materials, photodetectors and readout electronics. A special focus is put on metamaterials, as a new approach to bring more functionality to detection devices. It is shown that the route is now open towards a fully digital detector head with very high photon counting capability over a large energy range, excellent timing precision and possibility of imaging the energy deposition process.

  17. Dedicated brain PET system of PET/MR for brain research

    International Nuclear Information System (INIS)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng

    2015-01-01

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  18. PET/CT assessment in follicular lymphoma using standardized criteria: central review in the PRIMA study

    Energy Technology Data Exchange (ETDEWEB)

    Tychyj-Pinel, Christelle [Service de Medecine Nucleaire, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Ricard, Fabien [Service de Medecine Nucleaire, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Universite de Lyon, Faculte de Medecine, UCB Lyon 1, Lyon (France); Fulham, Michael [Royal Prince Alfred Hospital, Department of PET and Nuclear Medicine, Sydney (Australia); University of Sydney, Sydney Medical School, Sydney (Australia); Fournier, Marion [Centre Hospitalier Lyon Sud, The Lymphoma Academic Research Organisation (LYSARC), Pierre-Benite (France); Meignan, Michel [CHU Henri Mondor, Medicine Nucleaire, Creteil (France); Lamy, Thierry [Service d' Hematologie, CHU, Rennes (France); Vera, Pierre [Centre Henri Becquerel, Service de Medecine Nucleaire, Rouen (France); Rouen University, QuantIF (Litis EA4108), Rouen (France); Salles, Gilles [Universite de Lyon, Faculte de Medecine, UCB Lyon 1, Lyon (France); Service d' Hematologie, Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, Pierre-Benite (France); Trotman, Judith [University of Sydney, Sydney Medical School, Sydney (Australia); Concord Hospital, Department of Haematology, Concord, NSW (Australia)

    2014-03-15

    We aimed to compare the standardized central review of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT scans performed after induction therapy for follicular lymphoma (FL) in the PRIMA study (Salles et al., Lancet 377:42-51, 2011; Trotman et al., J Clin Oncol 29:3194-3200, 2011) to scan review at local centres. PET/CT scans were independently evaluated by two nuclear medicine physicians using the 2007 International Harmonization Project (IHP) criteria (Cheson et al., J Clin Oncol 25:579-586, 2007; Juweid et al., J Clin Oncol 25:571-578, 2007; Shankar et al., J Nucl Med 47:1059-1066, 2006) and Deauville 5-point scale (5PS) criteria (Meignan et al., Leuk Lymphoma 50:1257-1260, 2009; Meignan et al., Leuk Lymphoma 51:2171-2180, 2010; Barrington et al., Eur J Nucl Med Mol Imaging 37:1824-1833, 2010). PET/CT status was compared with prospectively recorded patient outcomes. Central evaluation was performed on 119 scans. At diagnosis, 58 of 59 were recorded as positive, with a mean maximum standardized uptake value (SUV{sub max}) of 11.7 (range 4.6-35.6). There was no significant association between baseline SUV{sub max} and progression-free survival (PFS). Sixty post-induction scans were interpreted using both the IHP criteria and 5PS. Post-induction PET-positive status failed to predict progression when applying the IHP criteria [p = 0.14; hazard ratio (HR) 1.9; 95 % confidence interval (CI) 0.8-4.6] or 5PS with a cut-off ≥3 (p = 0.12; HR 2.0; 95 % CI 0.8-4.7). However, when applying the 5PS with a cut-off ≥4, there was a significantly inferior 42-month PFS in PET-positive patients of 25.0 % (95 % CI 3.7-55.8 %) versus 61.4 % (95 % CI 45.4-74.1 %) in PET-negative patients (p = 0.01; HR 3.1; 95 % CI 1.2-7.8). The positive predictive value (PPV) of post-induction PET with this liver cut-off was 75 %. The 42-month PFS for patients remaining PET-positive by local assessment was 31.1 % (95 % CI 10.2-55.0 %) vs 64.6 % (95 % CI 47.0-77.6 %) for PET

  19. Amyloid- and FDG-PET imaging in amyotrophic lateral sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Matias-Guiu, Jordi A.; Pytel, Vanesa; Galan, Lucia; Valles-Salgado, Maria; Guerrero, Antonio; Moreno-Ramos, Teresa; Matias-Guiu, Jorge [Hospital Clinico San Carlos, San Carlos Institute for Health Research (IdISSC), Universidad Complutense de Madrid, Department of Neurology, Madrid (Spain); Cabrera-Martin, Maria Nieves; Carreras, Jose Luis [Hospital Clinico San Carlos, San Carlos Institute for Health Research (IdISSC), Universidad Complutense de Madrid, Department of Nuclear Medicine, Madrid (Spain)

    2016-10-15

    We aimed to study brain metabolism and presence of beta-amyloid deposits using positron emission tomography (PET) in patients with amyotrophic lateral sclerosis (ALS). This prospective cross-sectional study included 18 patients with definite or probable ALS according to the revised El Escorial diagnostic criteria, and 24 healthy controls. Patients underwent neurological and neuropsychological assessments, PET with {sup 18}F-fluorodeoxyglucose (FDG), and amyloid-PET with {sup 18}F-florbetaben. Patients with ALS showed hypometabolism in the frontal area and hypermetabolism in the cerebellum compared to healthy controls. Four patients (22 %) displayed cognitive impairment and decreased metabolism in the frontal area extending bilaterally to the parietal regions, and increased metabolism in the posterior area of the cerebellum. In patients with no cognitive impairment, metabolism was lower in the left superior frontal gyrus and higher in the anterior and posterior lobes of the cerebellum. In the individual analysis, six patients (35 %) displayed more anterior involvement with hypometabolism affecting the superior frontal, medial, and inferior gyri; six patients (35 %) exhibited a more posterior pattern with hypometabolism in the precentral and postcentral gyri and in the superior and inferior parietal lobules; two patients (11 %) showed a mixed pattern; and three patients (17 %) showed no alterations in brain metabolism. Three (16 %) showed increased {sup 18}F-florbetaben uptake compared to controls. We have identified two main patterns of brain metabolism with an association to cognitive status. Only a subgroup of patients showed an increased uptake of the amyloid tracer. Our results suggest that ALS is heterogeneous from a clinical, metabolic, and molecular standpoint. (orig.)

  20. Neuroreceptor and its transporters imaging by PET and SPECT in heroin addiction

    International Nuclear Information System (INIS)

    Yuan Jie; Liu Xingdang; Han Mei

    2013-01-01

    Heroin abuse can cause prominent hazardous effects,including the collapse of social,economic status and health. The research of heroin addiction mechanism has got some progress, but the neurotransmitter and receptor mechanism are still not clear. This review discussed potential neurobiology mechanisms of heroin addiction, including opioid receptor, dopamine receptors and dopamine transporters in different brain areas when exposed to heroin and the application of PET and SPECT imaging of Neuroreceptor and its transporters in heroin addiction research. (authors)

  1. [Business administration of PET facilities: a nationwide survey for prices of PET screening and a cost analysis of three facilities].

    Science.gov (United States)

    Mitsutake, Naohiro; Fujii, Ryo; Oku, Shinya; Furui, Yuji; Yasunaga, Hideo

    2007-05-01

    The purpose of this study is to analyze the business administration of PET facilities based on the survey of the price of PET cancer screening and cost analysis of PET examination. The questionnaire survey of the price of PET cancer screening was implemented for all PET facilities in Japan. Cost data of PET examination, including fixed costs and variable costs, were obtained from three different medical institutions. The marked price of the PET cancer screening was 111,499 yen in average, and the most popular range of prices was between 80,000 yen and 90,000 yen. Costs of PET per examination were accounted for 110,675 yen, 79,158 yen and Y11,644 yen in facility A, B and C, respectively. The results suggested that facilities with two or more PET/CT per a cyclotron could only secure profits. In Japan, the boom in PET facility construction could not continue in accordance with increasing number of PET facilities. It would become more essential to analyze the appropriate distribution of PET facilities and the adequate amount of PET procedures from the perspective of efficient utilization of the PET equipments and supply of PET-related healthcare.

  2. Therapy assessment in multiple myeloma with PET

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina [Medicina Nucleare Metropolitana di Bologna, Bologna (Italy); Zamagni, Elena [Bologna University School of Medicine, Seragnoli Institute of Hematology, Bologna (Italy)

    2017-08-15

    Multiple myeloma is a plasma cell dyscrasia producing bone lytic lesions. In recent years, a wide spectrum of therapeutic approaches are available to treat the disease: an accurate therapy assessment has, therefore, become of utmost importance. In this field, imaging is becoming a cornerstone, especially in association with clinical parameters. Among imaging procedures, FDG PET/CT is recognized to provide reliable information, achieved in a very safe and fast procedure. The literature has produced very concordant results from different groups assessing the value of FDG PET/CT as a prognostic factor in general and in therapy assessment, but some issues remain regarding a standardization of image interpretation especially in borderline cases. So far, no data regarding nor other imaging compounds and the use of hybrid tomographs PET/MR are available to define therapy assessment in PET. (orig.)

  3. Autism spectrum disorder and pet therapy.

    Science.gov (United States)

    Siewertsen, Caitlin M; French, Emma D; Teramoto, Masaru

    2015-01-01

    Autism Spectrum Disorder (ASD) encompasses a wide range of social and mental afflictions that are difficult to treat. Due to a lack of established treatments for ASD, alternative therapies have been the primary form of intervention. One of these alternatives is pet therapy, a field that has experienced growing interest and has recently accumulated studies that investigate its efficacy. This article reviews and summarizes that effectiveness as well as the findings and limitations associated with pet therapy for ASD. The majority of research on ASD and pet therapy has examined children and has primarily used dogs and horses for therapy. Studies have shown positive effects for the therapy, including high satisfaction rates among the participants' families. Major limitations of studies in the current literature include the lack of control groups and small sample sizes. Future research should incorporate better study designs and large samples to validate pet therapy as an appropriate treatment for ASD.

  4. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  5. Don't Just Pet Your Chia.

    Science.gov (United States)

    Hershey, David R.

    1995-01-01

    Presents ways to use ChiaPets to link biology-related topics such as taxonomy, morphology, ethnobotany, economic botany, hydroponics, salinity, photomorphogenesis, and phototropism with food and fertilizer chemistry, mathematics, art, and history. (MKR)

  6. Pet Ownership and the Risk of Dying from Cardiovascular Disease Among Adults Without Major Chronic Medical Conditions.

    Science.gov (United States)

    Ogechi, Imala; Snook, Kassandra; Davis, Bionca M; Hansen, Andrew R; Liu, Fengqi; Zhang, Jian

    2016-09-01

    In a recent statement, the American Heart Association stated "There are scant data on pet ownership and survival in people without established cardiovascular disease (CVD)". This study sought to fill this gap. We analyzed nationally representative data of 3964 adults aged ≥50 who were free from major physical illnesses. Pet ownership was assessed at baseline between 1988 and 1994. Vital status was followed through December 31st 2006. With dogs being most popular pets owned by 22.0 (standard error 0.34) % of the participants, 34.6 % of the study population owned a pet. Pet ownership was associated with low rates of CVD deaths [hazard ratio (HR) = 0.69 (95 % CI 0.45-1.07)] and stroke [0.54 (0.28-1.01)] at borderline significant levels among women. These associations were adjusted for physical activity and largely attributed to having a cat rather than a dog. Among cat owners, the HR of all CVD deaths was 0.62 (0.36-1.05) and the HR of dying from stroke was 0.22 (0.07-0.68) compared with non-cat owners. The corresponding HRs among dog owners were 0.82 (0.51-1.34) and 0.76 (0.34-1.71) respectively. No similar associations were observed among men. The hazard of dying from hypertension was not associated with pet ownership for both men and women. Owning a cat rather than a dog was significantly associated with a reduced hazard of dying from CVD events, in particular, stroke. The protection pets confer may not be from physical activities, but possibly due to personality of the pet owners or stress-relieving effects of animal companionship.

  7. Dynamic neurotransmitter interactions measured with PET

    International Nuclear Information System (INIS)

    Schiffer, W.K.; Dewey, S.L.

    2001-01-01

    Positron emission tomography (PET) has become a valuable interdisciplinary tool for understanding physiological, biochemical and pharmacological functions at a molecular level in living humans, whether in a healthy or diseased state. The utility of tracing chemical activity through the body transcends the fields of cardiology, oncology, neurology and psychiatry. In this, PET techniques span radiochemistry and radiopharmaceutical development to instrumentation, image analysis, anatomy and modeling. PET has made substantial contributions in each of these fields by providing a,venue for mapping dynamic functions of healthy and unhealthy human anatomy. As diverse as the disciplines it bridges, PET has provided insight into an equally significant variety of psychiatric disorders. Using the unique quantitative ability of PET, researchers are now better able to non-invasively characterize normally occurring neurotransmitter interactions in the brain. With the knowledge that these interactions provide the fundamental basis for brain response, many investigators have recently focused their efforts on an examination of the communication between these chemicals in both healthy volunteers and individuals suffering from diseases classically defined as neurotransmitter specific in nature. In addition, PET can measure the biochemical dynamics of acute and sustained drug abuse. Thus, PET studies of neurotransmitter interactions enable investigators to describe a multitude of specific functional interactions in the human brain. This information can then be applied to understanding side effects that occur in response to acute and chronic drug therapy, and to designing new drugs that target multiple systems as opposed to single receptor types. Knowledge derived from PET studies can be applied to drug discovery, research and development (for review, see (Fowler et al., 1999) and (Burns et al., 1999)). Here, we will cover the most substantial contributions of PET to understanding

  8. Dynamic neurotransmitter interactions measured with PET

    Energy Technology Data Exchange (ETDEWEB)

    Schiffer, W.K.; Dewey, S.L.

    2001-04-02

    Positron emission tomography (PET) has become a valuable interdisciplinary tool for understanding physiological, biochemical and pharmacological functions at a molecular level in living humans, whether in a healthy or diseased state. The utility of tracing chemical activity through the body transcends the fields of cardiology, oncology, neurology and psychiatry. In this, PET techniques span radiochemistry and radiopharmaceutical development to instrumentation, image analysis, anatomy and modeling. PET has made substantial contributions in each of these fields by providing a,venue for mapping dynamic functions of healthy and unhealthy human anatomy. As diverse as the disciplines it bridges, PET has provided insight into an equally significant variety of psychiatric disorders. Using the unique quantitative ability of PET, researchers are now better able to non-invasively characterize normally occurring neurotransmitter interactions in the brain. With the knowledge that these interactions provide the fundamental basis for brain response, many investigators have recently focused their efforts on an examination of the communication between these chemicals in both healthy volunteers and individuals suffering from diseases classically defined as neurotransmitter specific in nature. In addition, PET can measure the biochemical dynamics of acute and sustained drug abuse. Thus, PET studies of neurotransmitter interactions enable investigators to describe a multitude of specific functional interactions in the human brain. This information can then be applied to understanding side effects that occur in response to acute and chronic drug therapy, and to designing new drugs that target multiple systems as opposed to single receptor types. Knowledge derived from PET studies can be applied to drug discovery, research and development (for review, see (Fowler et al., 1999) and (Burns et al., 1999)). Here, we will cover the most substantial contributions of PET to understanding

  9. Multistate Outbreak of Human Salmonella Typhimurium Infections Linked to Pet Hedgehogs - United States, 2011-2013.

    Science.gov (United States)

    Anderson, T C; Marsden-Haug, N; Morris, J F; Culpepper, W; Bessette, N; Adams, J K; Bidol, S; Meyer, S; Schmitz, J; Erdman, M M; Gomez, T M; Barton Behravesh, C

    2017-06-01

    Zoonotic Salmonella infections cause approximately 130 000 illnesses annually in the United States. Of 72.9 million US households owning at least one pet, five million own small mammals; 3000 hedgehogs were documented by USDA in USDA-licensed breeding facilities and pet stores in 2012. State health department collaborators and PulseNet, the national bacterial subtyping network, identified human infections of a Salmonella Typhimurium outbreak strain, which were investigated by CDC, USDA-APHIS and state public and animal health officials. A case was defined as an illness in a person infected with the outbreak strain identified between 1 December 2011 and 3 June 2013. Investigators collected information on patient exposures, cultured animal and environmental specimens for Salmonella, and conducted traceback investigations of USDA-licensed hedgehog facilities. There were 26 cases in 12 states. Illness onset dates ranged from 26 December 2011 to 8 April 2013. The median patient age was 15 years (range = pet hedgehog contact in the week before illness onset. The outbreak strain was isolated from animal and environmental samples collected from three ill persons' homes in three states. Hedgehogs were purchased in geographically distant states from USDA-licensed breeders (10/17, 59%); a USDA-licensed pet store (1/17, 6%); unlicensed or unknown status breeders (3/17, 18%); and private individuals (3/17, 18%). Traceback investigations of USDA-licensed facilities did not reveal a single source of infection. Public and animal health collaboration linked pet hedgehog contact to human infections of Salmonella Typhimurium, highlighting the importance of a One Health investigative approach to zoonotic salmonellosis outbreaks. More efforts are needed to increase awareness among multiple stakeholders on the risk of illness associated with pet hedgehogs. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  10. PET and PET/CT imaging for the earliest detection and treatment of colorectal carcinoma

    Directory of Open Access Journals (Sweden)

    Kevin Carter

    2005-10-01

    Full Text Available Approximately 150,000 new cases of colorectal cancer are diagnosed each year with the life time risk of developing colon caner in developed nations being 4.6% in men and 3.2% in women. Screening patients is essential early detection of colon carcinoma to aid in complete resection. Unfortunately current screening methods carry with them poor patient compliance. PET and PET/CT may be a significant part of this screening solution. The authors reviewed and analyzed the English language articles and case reports identified on Medline during the last 10 years. PET and PET/CT results for colorectal carcinoma were tabulated and presented for the fifth Scientific Meeting of the Brazilian Society of Nuclear Biosciences. Though most studies have been retrospective analysis in using PET for staging for other malignant processes the cases that have identified additional uptake in the colon are important. The accuracy when utilizing PET and PET/CT in this screening method has a sensitivity between 65 and 90% with a specificity of 84 to 90% and a positive predictive value 71 to 78%. Early stages of malignancies and pre-cancerous polyps avidly accumulates F-18 Deoxyflouro glucose allowing us to conclude that whole body PET and PET/CT is an essential component in the work up, staging or treatment monitoring in colon carcinoma. We have to continue to accumulate data for possible introduction for whole body PET and PET/CT scanning for colon carcinoma and precancerous polyps.Aproximadamente, 150 000 novos casos de câncer coloretal são diagnosticados, anualmente, em países em desenvolvimento. Destes, 4,6% em homens e 3,2% em mulheres. A triagem de pacientes é essencial na detecção precoce do carcinoma de colon para ajudar na completa ressecção. Infelizmente, os métodos de exame atualmente disponíveis contam com uma baixa adesão dos pacientes. Parte significativa da solução desse problema pode estar no uso de PET e PET/CT. Os autores revisaram e

  11. Radiopharmaceuticals in PET, Progress and Promise

    Science.gov (United States)

    Wolf, A. P.; Fowler, J. S.

    1988-11-01

    It is the intention of this presentation to focus on the current state of radiopharmaceuticals for PET and where this is leading us. PET radiopharmaceuticals can be broken down into perhaps seven categories at present with each being applicable to a different aspect of human biochemistry. These are: metabolic probes, neurochemical probes, enzyme probes, ion channel blockers, blood flow agents, ethical drugs and other positron emitters.

  12. PET/MRI. Methodology and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Carrio, Ignasi [Autonomous Univ. of Barcelona, Hospital Sant Pau (Spain). Dept. Medicina Nuclear; Ros, Pablo (ed.) [Univ. Hospitals Case, Medical Center, Cleveland, OH (United States). Dept. of Radiology

    2014-04-01

    Provides detailed information on the methodology and equipment of MRI-PET. Covers a wide range of clinical applications in oncology, cardiology, and neurology. Written by an international group of experts in MRI and PET. PET/MRI is an exciting novel diagnostic imaging modality that combines the precise anatomic and physiologic information provided by magnetic resonance imaging (MRI) with the molecular data obtained with positron emission tomography (PET). PET/MRI offers the promise of a simplified work flow, reduced radiation, whole-body imaging with superior soft tissue contrast, and time of flight physiologic information. It has been described as the pathway to molecular imaging in medicine. In compiling this textbook, the editors have brought together a truly international group of experts in MRI and PET. The book is divided into two parts. The first part covers methodology and equipment and comprises chapters on basic molecular medicine, development of specific contrast agents, MR attenuation and validation, quantitative MRI and PET motion correction, and technical implications for both MRI and PET. The second part of the book focuses on clinical applications in oncology, cardiology, and neurology. Imaging of major neoplasms, including lymphomas and tumors of the breast, prostate, and head and neck, is covered in individual chapters. Further chapters address functional and metabolic cardiovascular examinations and major central nervous system applications such as brain tumors and dementias. Risks, safety aspects, and healthcare costs and impacts are also discussed. This book will be of interest to all radiologists and nuclear medicine physicians who wish to learn more about the latest developments in this important emerging imaging modality and its applications.

  13. Sea otter health: Challenging a pet hypothesis

    OpenAIRE

    Lafferty, Kevin D.

    2015-01-01

    A recent series of studies on tagged sea otters (Enhydra lutris nereis) challenges the hypothesis that sea otters are sentinels of a dirty ocean, in particular, that pet cats are the main source of exposure to Toxoplasma gondii in central California. Counter to expectations, sea otters from unpopulated stretches of coastline are less healthy and more exposed to parasites than city-associated otters. Ironically, now it seems that spillover from wildlife, not pets, dominates spatial patterns of...

  14. Sea otter health: Challenging a pet hypothesis

    Directory of Open Access Journals (Sweden)

    Kevin D. Lafferty

    2015-12-01

    Full Text Available A recent series of studies on tagged sea otters (Enhydra lutris nereis challenges the hypothesis that sea otters are sentinels of a dirty ocean, in particular, that pet cats are the main source of exposure to Toxoplasma gondii in central California. Counter to expectations, sea otters from unpopulated stretches of coastline are less healthy and more exposed to parasites than city-associated otters. Ironically, now it seems that spillover from wildlife, not pets, dominates spatial patterns of disease transmission.

  15. Sea otter health: Challenging a pet hypothesis.

    Science.gov (United States)

    Lafferty, Kevin D

    2015-12-01

    A recent series of studies on tagged sea otters (Enhydra lutris nereis) challenges the hypothesis that sea otters are sentinels of a dirty ocean, in particular, that pet cats are the main source of exposure to Toxoplasma gondii in central California. Counter to expectations, sea otters from unpopulated stretches of coastline are less healthy and more exposed to parasites than city-associated otters. Ironically, now it seems that spillover from wildlife, not pets, dominates spatial patterns of disease transmission.

  16. Sea otter health: challenging a pet hypothesis

    Science.gov (United States)

    Lafferty, Kevin D.

    2015-01-01

    A recent series of studies on tagged sea otters (Enhydra lutris nereis) challenges the hypothesis that sea otters are sentinels of a dirty ocean, in particular, that pet cats are the main source of exposure to Toxoplasma gondii in central California. Counter to expectations, sea otters from unpopulated stretches of coastline are less healthy and more exposed to parasites than city-associated otters. Ironically, now it seems that spillover from wildlife, not pets, dominates spatial patterns of disease transmission.

  17. PET tracer for imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    2013-01-01

    There is provided a radiolabelled peptide-based compound for diagnostic imaging using positron emission tomography (PET). The compound may thus be used for diagnosis of malignant diseases. The compound is particularly useful for imaging of somatostatin overexpression in tumors, wherein the compound...... is capable of being imaged by PET when administered with a target dose in the range of 150-350 MBq, such as 150-250 MBq, preferable in the range of 191-210 MBq....

  18. CA 125, PET alone, PET-CT, CT and MRI in diagnosing recurrent ovarian carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gu Ping [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127 (China)], E-mail: anita.gu.ping@gmail.com; Pan Lingling; Wu Shuqi [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127 (China); Sun Li [Departments of Oncology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Huang Gang [Department of Nuclear Medicine, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127 (China)], E-mail: huang2802@163.com

    2009-07-15

    Background and purpose: Ovarian cancer is the commonest tumor in female patients with a propensity for recurrence even after primary chemotherapy in early stage. The accuracy of CA 125, PET alone, PET-CT, CT and MRI in diagnosing the recurrent ovarian carcinoma has never been systematically assessed, and present systematic review was aimed at this issue. Methods: We searched for articles published from January 1995 to November 2007, inclusion criteria including: articles were reported in English or Chinese; CA 125, PET whether interpreted with or without the use of CT, CT or MRI was used to detect recurrent ovarian carcinoma; Histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months. We extracted data to calculate sensitivity, specificity, SROC curves and AUC and to test for heterogeneity. Result: In 34 included studies, CA 125 had the highest pooled specificity, 0.93 (95% CI: 0.89-0.95); PET-CT had highest pooled sensitivity, 0.91 (95% CI: 0.88-0.94). The AUC of CA 125, PET alone, PET-CT, CT and MRI were 0.9219, 0.9297, 0.9555, 0.8845 and 0.7955, respectively. Results of pairwise comparison between each modality demonstrated AUC of PET, whether interpreted with or without the use of CT, was higher than that of CT or MR, p < 0.05. The pooled sensitivity, pooled specificity and AUC showed no statistical significance between PET alone and PET-CT. There was heterogeneity among studies and evidence of publication bias. Conclusion: PET-CT might be a useful supplement to current surveillance techniques, particularly for those patients with an increasing CA 125 level and negative CT or MR imaging. However, regarding to diagnostic accuracy, interpreted CT images may have limited additional value on PET in detecting recurrent ovarian cancer.

  19. FDG-PET and FDG-PET/CT for therapy monitoring and restaging in malignant lymphoma

    International Nuclear Information System (INIS)

    Mottaghy, F.M.; Krause, B.J.

    2003-01-01

    F-18-fluorodeoxyglucose (FDG) PET allows to assess residual masses in patients with malignant lymphoma differentiating vital tumor from scar tissue. This approach is not applicable with conventional imaging methods (CDM) such as CT or MRI. On the other hand circumscribed results often cannot be definitely allocated in PET, therefore the combined morphological-biochemical approach using the now available PET/CT systems promises to be a pathbreaking technical progress. There is no doubt that stand alone PET is superior to CDM differentiating residual scar tissue from vital tumor as has been shown in 15 recently published studies. The median sensitivity for detecting active disease with FDG PET across the studies was 91%; the corresponding specificity was 89%. As a result FDG PET had a high negative predictive value of 94%. In contrast, specificity and positive predictive value (PPV) of CDM in the 9 studies were a direct comparison was available were low (31% and 46%, one study 82%). PET positive residual masses were associated with a progression-free survival of 0 - 55%. Only a few studies have included FDG-PET in therapy response monitoring studies, however also these results are promising. At the moment FDG-PET seems to be the best possibility to characterize and qualitatively visualize vitality of tumor masses and also hold promises for efficient therapy response monitoring in patients with malignant lymphoma. Therefore it should be included in standard diagnostic protocols in lymphoma patients. The combined PET/CT has to be ranked superior to conventional PET studies as in many cases the combined structural and functional imaging brings a clearer diagnostic statement. (orig.) [de

  20. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  1. Can body volume be determined by PET?

    Energy Technology Data Exchange (ETDEWEB)

    Hentschel, Michael; Paul, Dominik; Mix, Michael; Moser, Ernst; Brink, Ingo [University Hospital Freiburg, Division of Nuclear Medicine, Section of Positron Emission Tomography, Freiburg (Germany); Korsten-Reck, Ulrike [University Hospital Freiburg, Division of Sports Medicine, Freiburg (Germany); Mueller, Frank [PET-Institute Rhein-Neckar, Ludwigshafen (Germany); Merk, Stefan [Kantonsspital Basel, Division of Nuclear Medicine, Basel (Switzerland)

    2005-04-01

    To avoid dependence on body weight, the standardised uptake value (SUV) in positron emission tomography (PET) can instead be normalised to the lean body mass (LBM), which can be determined from body volume and mass. This study was designed to answer the following questions: Firstly, can the total body volume in principle be determined using PET? Secondly, is the precision of this measurement comparable to that achieved using an established standard method. Ten patients were examined during oncological whole-body PET examinations. The whole-body volume of the patients was determined from the transmission scan in PET. Air displacement plethysmography with BOD POD was used for comparison as the standard method of volume determination. In all patients, the whole-body volumes could be determined using PET and the standard method. Bland and Altman [23] analysis for agreement between the volumes determined by the two methods (presentation of differences vs means) revealed a very small difference of -0.14 l. With a mean patient volume of 71.81{+-}15.93 l, the relative systematic error is only <0.1%. On this basis, equality of the volume values determined by the two methods can be assumed. PET can be used as a supplementary method for experimental determination of whole-body volume and total body fat in tumour patients. The fat content can be used to calculate the LBM and to determine body weight-independent SUVs (SUV{sub LBM}). (orig.)

  2. Nutritional Sustainability of Pet Foods12

    Science.gov (United States)

    Swanson, Kelly S.; Carter, Rebecca A.; Yount, Tracy P.; Aretz, Jan; Buff, Preston R.

    2013-01-01

    Sustainable practices meet the needs of the present without compromising the ability of future generations to meet their needs. Applying these concepts to food and feed production, nutritional sustainability is the ability of a food system to provide sufficient energy and essential nutrients required to maintain good health in a population without compromising the ability of future generations to meet their nutritional needs. Ecological, social, and economic aspects must be balanced to support the sustainability of the overall food system. The nutritional sustainability of a food system can be influenced by several factors, including the ingredient selection, nutrient composition, digestibility, and consumption rates of a diet. Carbon and water footprints vary greatly among plant- and animal-based ingredients, production strategy, and geographical location. Because the pet food industry is based largely on by-products and is tightly interlinked with livestock production and the human food system, however, it is quite unique with regard to sustainability. Often based on consumer demand rather than nutritional requirements, many commercial pet foods are formulated to provide nutrients in excess of current minimum recommendations, use ingredients that compete directly with the human food system, or are overconsumed by pets, resulting in food wastage and obesity. Pet food professionals have the opportunity to address these challenges and influence the sustainability of pet ownership through product design, manufacturing processes, public education, and policy change. A coordinated effort across the industry that includes ingredient buyers, formulators, and nutritionists may result in a more sustainable pet food system. PMID:23493530

  3. Effect of PET functionalization in composites of

    Directory of Open Access Journals (Sweden)

    Cristina Cazan

    2017-03-01

    Full Text Available The functionalization of polyethylene terephthalate (PET from tire rubber–PET–high density polyethylene (HDPE composites represents a key strategy for improving the composite properties. This is a practical and effective method to improve the interface between matrix (waste tire rubber and fillers (waste PET and HDPE. By PET functionalization, adherence and surface properties of composite materials can be controlled. PET functionalization was performed with polyethylene glycol (PEG 400, 1% and sodium dodecyl sulphate (SDS 1%. The characterization of the components and composite are discussed in terms of surface energy values (evaluated from water contact angle measurements and surface morphology by using scanning electron microscopy (SEM. The structural and conformational changes were investigated by Fourier Transform Infrared (FTIR Spectroscopy while the crystalline structure was studied by X-ray diffraction (XRD. The improved interfacial adhesion, thermal stability and mechanical properties (stress–strain, compression and impact resistance of the composites are correlated with the PET functionalization, with non-ionic (PEG and an anionic surfactant (SDS. The results proved that the interface properties are improved by functionalization of PET. The best mechanical properties were recorded at 30 min moulding. The samples with 45% PET–SDS showed the best combination of mechanical properties: tensile strength (1.56 N/mm2, impact strength (43.72 kJ/m2 and compression (158.78 N/mm2.

  4. Positron emission tomography (PET) and pancreatic tumours

    International Nuclear Information System (INIS)

    Montravers, F.; Kerrou, K.; Grahek, D.; Gutman, F.; Beco, V. de; Talbot, J.N.

    2005-01-01

    Neoplasms of the pancreas may originate front both exocrine and endocrine cells but in 90% of the cases, they correspond to ductal adenocarcinomas. For adenocarcinomas, the major indication of FDG-PET corresponds to the pre-operative staging because unexpected distant metastases can be detected by FDG-PET in about 20 to 40% of the cases, which results in avoidance of unnecessary surgical procedures. FDG PET is also useful in evaluation of the treatment effect, monitoring after the operation and detection of recurrent pancreatic cancers. For the characterisation of the pancreatic tumour, the performance of FDG-PET is sometimes limited due to poor cellularity, hyperglycemia or inflammatory processes. especially for large tumours and is indicated only in cases of doubtful results of CT or MRI. For endocrine pancreatic tumours, FDG-PET is useful only in case of poorly-differentiated and aggressive tumours. F-DOPA PET can he useful, complementary to pentetreotide scintigraphy, in well-differentiated endocrine tumours. (authors)

  5. Clinical application of PET in abdominal cancers

    International Nuclear Information System (INIS)

    Choi, Chang Woon

    2002-01-01

    Clinical application of positron emission tomography (PET) is rapidly increasing for the detection and staging of cancer at whole-body studies performed with the glucose analogue tracer 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FG). Although FDG PET cannot match the anatomic resolution of conventional imaging techniques in the liver and the other abdominal organs, it is particularly useful for identification and characterization of the entire body simultaneously. FDG PET can show foci of metastatic disease that may not be apparent at conventional anatomic imaging and can aid in the characterizing of indeterminate soft-tissue masses. Most abdominal cancer requires surgical management. FGD PET can improve the selection of patients for surgical treatment and thereby reduce the morbidity and mortality associated with inappropriate surgery. FDG PET is also useful for the early detection of recurrence and the monitoring of therapeutic effect. The abdominal cancers, such as gastroesophageal cancer, colorectal cancer, liver cancer and pancreatic cancer, are common malignancies in Korea, and PET is one of the most promising and useful methodologies for the management of abdominal cancers

  6. Eye Contact Is Crucial for Referential Communication in Pet Dogs.

    Science.gov (United States)

    Savalli, Carine; Resende, Briseida; Gaunet, Florence

    2016-01-01

    Dogs discriminate human direction of attention cues, such as body, gaze, head and eye orientation, in several circumstances. Eye contact particularly seems to provide information on human readiness to communicate; when there is such an ostensive cue, dogs tend to follow human communicative gestures more often. However, little is known about how such cues influence the production of communicative signals (e.g. gaze alternation and sustained gaze) in dogs. In the current study, in order to get an unreachable food, dogs needed to communicate with their owners in several conditions that differ according to the direction of owners' visual cues, namely gaze, head, eyes, and availability to make eye contact. Results provided evidence that pet dogs did not rely on details of owners' direction of visual attention. Instead, they relied on the whole combination of visual cues and especially on the owners' availability to make eye contact. Dogs increased visual communicative behaviors when they established eye contact with their owners, a different strategy compared to apes and baboons, that intensify vocalizations and gestures when human is not visually attending. The difference in strategy is possibly due to distinct status: domesticated vs wild. Results are discussed taking into account the ecological relevance of the task since pet dogs live in human environment and face similar situations on a daily basis during their lives.

  7. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    ... Refresher Courses · Symposia · Live Streaming. Home; Journals; Bulletin of Materials Science; Volume 39; Issue 1. Processing and characterization of extruded PET and its r-PET and MWCNT nanocomposite thin films by spin coating. Arvind R Singh Vineeta D Deshpande. Volume 39 Issue 1 February 2016 pp 167-175 ...

  8. Guidelines for 18F-FDG PET and PET-CT imaging in paediatric oncology

    DEFF Research Database (Denmark)

    Stauss, J.; Franzius, C.; Pfluger, T.

    2008-01-01

    tomography ((18)F-FDG PET) in paediatric oncology. The Oncology Committee of the European Association of Nuclear Medicine (EANM) has published excellent procedure guidelines on tumour imaging with (18)F-FDG PET (Bombardieri et al., Eur J Nucl Med Mol Imaging 30:BP115-24, 2003). These guidelines, published...

  9. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    and MWCNT nanocomposite thin films by spin coating. ARVIND R SINGH1,2 and ... spin coating using reorganized polyethylene terephthalate (r-PET) and multiwalled carbon nanotubes (MWCNTs) as fillers in PET. A study of the ... molecular weight and sol- vent type (viscosity, density and surface energy), spinning.

  10. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  11. PET/CT and dedicated PET in breast cancer: Implications for classification, staging, and response monitoring

    NARCIS (Netherlands)

    Koolen, B.B.

    2013-01-01

    De PET-CT, een scan die gebruik maakt van radioactiviteit om tumoren in beeld te brengen, is een zinvol instrument voor beeldvorming van patiënten met borstkanker, met name van patiënten met een tumor groter dan drie centimeter of tumor-positieve lymfeklieren. De PET-CT is vooral van waarde voor de

  12. Role of FDG-PET and PET/CT in the diagnosis and management of vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Zerizer, Imene; Tan, Kathryn; Khan, Sameer; Barwick, Tara [Department of Nuclear Medicine, Imperial College Healthcare, Hammersmith Hospital, Du Cane Road, London (United Kingdom); Marzola, Maria Cristina [Department of Nuclear Medicine, PET/CT Centre, Radiology and Medical Physics, ' Santa Maria della Misericordia' Hospital, Rovigo (Italy); Rubello, Domenico [Department of Nuclear Medicine, PET/CT Centre, Radiology and Medical Physics, ' Santa Maria della Misericordia' Hospital, Rovigo (Italy)], E-mail: domenico.rubello@libero.it; Al-Nahhas, Adil [Department of Nuclear Medicine, Imperial College Healthcare, Hammersmith Hospital, Du Cane Road, London (United Kingdom)

    2010-03-15

    Purpose: to investigate the role of FDG-PET and PET/CT in the evaluation of vasculitis. Materials and methods: a systematic revision of the papers published in PubMed/Medline until December 2009 was done. Results: FDG-PET and PET/CT have been proven to be valuable in the diagnosis of large-vessel vasculitis, especially giant cells arteritis with sensitivity values ranging 77% to 92%, and specificity values ranging 89% to 100%. In particular, FDG-PET/CT has demonstrated the potential to non-invasively diagnose the onset of the vasculitis earlier than traditional anatomical imaging techniques, thus enabling prompt treatment. False positive results mainly occur in the differential diagnosis between vasculitis and atherosclerotic vessels in elderly patients. Another area where FDG-PET/CT is gaining wider acceptance is in monitoring response to therapy; it can reliably detect the earliest changes of disease improvement post-therapy, and persistent activity is an indicator of non-responders to therapy. A few data have been reported about medium/small vessel vasculitis. Discussion: FDG-PET and PET/CT have proven utility: (a) in the initial diagnosis of patients suspected of having vasculitis particularly in those who present with non-specific symptoms; (b) in the identification of areas of increased FDG uptake in which a biopsy should be done for obtaining a diagnosis; (c) in evaluating the extent of the disease; (d) in assessing response to treatment.

  13. Role of FDG-PET and PET/CT in the diagnosis and management of vasculitis

    International Nuclear Information System (INIS)

    Zerizer, Imene; Tan, Kathryn; Khan, Sameer; Barwick, Tara; Marzola, Maria Cristina; Rubello, Domenico; Al-Nahhas, Adil

    2010-01-01

    Purpose: to investigate the role of FDG-PET and PET/CT in the evaluation of vasculitis. Materials and methods: a systematic revision of the papers published in PubMed/Medline until December 2009 was done. Results: FDG-PET and PET/CT have been proven to be valuable in the diagnosis of large-vessel vasculitis, especially giant cells arteritis with sensitivity values ranging 77% to 92%, and specificity values ranging 89% to 100%. In particular, FDG-PET/CT has demonstrated the potential to non-invasively diagnose the onset of the vasculitis earlier than traditional anatomical imaging techniques, thus enabling prompt treatment. False positive results mainly occur in the differential diagnosis between vasculitis and atherosclerotic vessels in elderly patients. Another area where FDG-PET/CT is gaining wider acceptance is in monitoring response to therapy; it can reliably detect the earliest changes of disease improvement post-therapy, and persistent activity is an indicator of non-responders to therapy. A few data have been reported about medium/small vessel vasculitis. Discussion: FDG-PET and PET/CT have proven utility: (a) in the initial diagnosis of patients suspected of having vasculitis particularly in those who present with non-specific symptoms; (b) in the identification of areas of increased FDG uptake in which a biopsy should be done for obtaining a diagnosis; (c) in evaluating the extent of the disease; (d) in assessing response to treatment.

  14. Development of Filtering Methods for PET Signals Contaminated by RF Pulses for Combined PET-MRI

    Science.gov (United States)

    Huh, Yoonsuk; Choi, Yong; Hong, Key Jo; Hu, Wei; Kang, Jihoon; Jung, Jin Ho; Song, Myung Sung; Park, Hyun-wook; Kim, Byung-Tae

    2013-10-01

    This paper presents the development of filtering methods for positron emission tomography (PET) signals contaminated by radio frequency (RF) pulses for combined PET and clinical 3-T magnetic resonance imaging (MRI). The filtering methods include software, hardware, and hybrid correction methods. In the software correction method, PET signals are assessed, and valid signals are identified based on the characteristics of a typical PET signal using Field-Programmable Gate Array (FPGA)-based programming. The hardware correction method makes use of differential-to-single-ended and low-pass filter circuits for PET analog signals. The hybrid correction method involves the sequential application of both the hardware and software methods. Both valid and contaminated PET signals are measured with an oscilloscope. An evaluation is then made of the performance (energy resolution, photopeak channel, total counts, and coincidence timing resolution) of the PET detector modules with and without various MR sequences (gradient echo, spin echo T1 sequence). For all correction methods, the energy resolution, photopeak position, and coincidence timing resolution with MR sequences are similar (noise signals and reduce count loss while preserving the valid analog signals of MR sequences, is reliable and useful for the development of simultaneous PET-MRI.

  15. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... Owing to the crystallizing behaviour of r-PET, it allows better dispersion of MWCNT in the polymer matrix as compared with PET. The samples with fillers of MWCNT show more compact and unique mesh-like globular structure, indicating application for electromagnetic shielding foams and fibres.

  16. An update on the role of PET/CT and PET/MRI in ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Khiewvan, Benjapa [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Mahidol University, Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine Siriraj Hospital, Bangkok (Thailand); Torigian, Drew A.; Emamzadehfard, Sahra; Paydary, Koosha; Salavati, Ali; Houshmand, Sina; Werner, Thomas J.; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2017-06-15

    This review article summarizes the role of PET/CT and PET/MRI in ovarian cancer. With regard to the diagnosis of ovarian cancer, the presence of FDG uptake within the ovary of a postmenopausal woman raises the concern for ovarian cancer. Multiple studies show that FDG PET/CT can detect lymph node and distant metastasis in ovarian cancer with high accuracy and may, therefore, alter the management to obtain better clinical outcomes. Although PET/CT staging is superior for N and M staging of ovarian cancer, its role is limited for T staging. Additionally, FDG PET/CT is of great benefit in evaluating treatment response and has prognostic value in patients with ovarian cancer. FDG PET/CT also has value to detect recurrent disease, particularly in patients with elevated serum CA-125 levels and negative or inconclusive conventional imaging test results. PET/MRI may beneficial for tumor staging because MRI has higher soft tissue contrast and no ionizing radiation exposure compared to CT. Some non-FDG PET radiotracers such as {sup 18}F-fluorothymidine (FLT) or {sup 11}C-methionine (MET) have been studied in preclinical and clinical studies as well and may play a role in the evaluation of patients with ovarian cancer. (orig.)

  17. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  18. Magnetic Resonance-Derived Improvements in PET Imaging.

    Science.gov (United States)

    Lalush, David S

    2017-05-01

    Simultaneous PET-MR imaging improves deficiencies in PET images. The primary areas in which magnetic resonance (MR) has been applied to guide PET results are in correction for patient motion and in improving the effects of PET resolution and partial volume averaging. MR-guided motion correction of PET has been applied to respiratory, cardiac, and gross body movements and shown to improve lesion detectability and contrast. Partial volume correction or resolution improvement of PET governed by MR imaging anatomic information improves visualization of structures and quantitative accuracy. Evaluation in clinical applications is needed to determine their true impacts. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    International Nuclear Information System (INIS)

    Berthelsen, A.K.; Holm, S.; Loft, A.; Klausen, T.L.; Andersen, F.; Hoejgaard, L.

    2005-01-01

    If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can be used for PET attenuation without reducing the clinical value of the PET scan. A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT scans without, and then with contrast agent, followed by an 18 F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global comparison of standard uptake value (SUV) was performed, and SUVs in tumour, in non-tumour tissue and in the subclavian vein were calculated. Clinical evaluation of the number and location of lesions on all PET/CT scans was performed twice, blinded and in a different random order, by two independent nuclear medicine specialists. In all patients, the measured global SUV of PET images based on CT with IV contrast agent was higher than the global activity using non-contrast correction. The overall increase in the mean SUV (for two different conversion tables tested) was 4.5±2.3% and 1.6±0.5%, respectively. In 11/19 patients, focal uptake was identified corresponding to malignant tumours. Eight out of 11 tumours showed an increased SUV max (2.9±3.1%) on the PET images reconstructed using IV contrast

  20. PET/CT or PET/MR for clinical molecular imaging in next decade

    International Nuclear Information System (INIS)

    Bal, C.S.

    2012-01-01

    In the era of molecular imaging, the true clinical benefits to patients started with use of hybrid equipment's (hardware integration of structural and functional imaging) since 2001, in the form of PET-CT. In a decade time more than 5000 PET-CT scanners have been installed all over the world including more than 50 in India. Application of 18 FDG PET-CT in oncology has revolutionized the patient management from staging/restaging of cancer, monitoring chemoradiotherapy and even predicting the outcome of multimodality interventions. The flip-side of the generous repeated use of PET-CT in all age groups has raised concern not only among professionals but also among patients as World Health Organization (WHO) has accepted radiation as a definite carcinogen. The numbers are very clear indication for the concern: out of 25 mSv delivered in a standard 18FDG PET-CT whole body scanning 18 mSv is due to CT and 7 mSv is due to 10 mCi 18FDG. Due to huge public outcry, all vendors have started building new scanners which delivered considerably lesser radiation dose to patient without compromising the brilliant image quality of PET-CT. Next logical approach is to replace CT with MR which is based-on non-ionizing radiation principles. The proof-of-principle equipment is PET-MR scanner. There are several technological challenges to built such machine and at the same time to keep the cost within affordable limit. The prototypes are being tested in industry-academia collaboration centres and the initial research articles are very promising. Integrating high resolution PET with 3 Tesla MR in a single machine is truly technological marvel. The significant benefits of PET-MR would be the inherent superior soft-tissue contrast, no radiation from MR (minimal radiation from 18FDG) and simultaneous cross evaluation of multiple imaging biomarker in the form of fMRI, DWI, PWI, tractography and spectroscopy, in addition to functional PET imaging. The true molecular imaging is born. As all good

  1. Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT--Initial Results.

    Science.gov (United States)

    Zeimpekis, Konstantinos G; Barbosa, Felipe; Hüllner, Martin; ter Voert, Edwin; Davison, Helen; Veit-Haibach, Patrick; Delso, Gaspar

    2015-10-01

    The purpose of this study was to compare only the performance of the PET component between a TOF-PET/CT (henceforth noted as PET/CT) scanner and an integrated TOF-PET/MRI (henceforth noted as PET/MRI) scanner concerning image quality parameters and quantification in terms of standardized uptake value (SUV) as a function of acquisition time (a surrogate of dose). The CT and MR image quality were not assessed, and that is beyond the scope of this study. Five brain and five whole-body patients were included in the study. The PET/CT scan was used as a reference and the PET/MRI acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of the emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts, and noise were evaluated. SUV measurements were taken in the liver and in the white matter to compare quantification. Quantitative evaluation showed strong correlation between PET/CT and PET/MRI brain SUVs. Liver correlation was good, however, with lower uptake estimation in PET/MRI, partially justified by bio-redistribution. The clinical evaluation showed that PET/MRI offers higher image quality and sharpness with lower levels of noise and artifacts compared to PET/CT with reduced acquisition times for whole-body scans while for brain scans there is no significant difference. The TOF-PET/MRI showed higher image quality compared to TOF-PET/CT as tested with reduced imaging times. However, this result accounts mainly for body imaging, while no significant differences were found in brain imaging.

  2. Present and future of PET and PET/CT in gynaecologic malignancies

    International Nuclear Information System (INIS)

    Musto, Alessandra; Rampin, Lucia; Nanni, Cristina; Marzola, Maria Cristina; Fanti, Stefano; Rubello, Domenico

    2011-01-01

    Objectives: To review the published data in literature on patients affected by gynaecological malignancies to establish the role of 18 F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI). Materials and methods: All papers specifically addressed to the role of 18 F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study. Results and conclusions: The use of 18 F-FDG PET, and even more of 18 F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that 18 F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of 18 F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of 18 F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.

  3. Bacteriophages safely reduceSalmonellacontamination in pet food and raw pet food ingredients.

    Science.gov (United States)

    Soffer, Nitzan; Abuladze, Tamar; Woolston, Joelle; Li, Manrong; Hanna, Leigh Farris; Heyse, Serena; Charbonneau, Duane; Sulakvelidze, Alexander

    2016-01-01

    Contamination of pet food with Salmonella is a serious public health concern, and several disease outbreaks have recently occurred due to human exposure to Salmonella tainted pet food. The problem is especially challenging for raw pet foods (which include raw meats, seafood, fruits, and vegetables). These foods are becoming increasingly popular because of their nutritional qualities, but they are also more difficult to maintain Salmonella -free because they lack heat-treatment. Among various methods examined to improve the safety of pet foods (including raw pet food), one intriguing approach is to use bacteriophages to specifically kill Salmonella serotypes. At least 2 phage preparations (SalmoFresh® and Salmonelex™) targeting Salmonella are already FDA cleared for commercial applications to improve the safety of human foods. However, similar preparations are not yet available for pet food applications. Here, we report the results of evaluating one such preparation (SalmoLyse®) in reducing Salmonella levels in various raw pet food ingredients (chicken, tuna, turkey, cantaloupe, and lettuce). Application of SalmoLyse® in low (ca. 2-4×10 6 PFU/g) and standard (ca. 9×10 6 PFU/g) concentrations significantly ( P foods examined compared to control treatments. When SalmoLyse®-treated (ca. 2×10 7 PFU/g) dry pet food was fed to cats and dogs, it did not trigger any deleterious side effects in the pets. Our data suggest that the bacteriophage cocktail lytic for Salmonella can significantly and safely reduce Salmonella contamination in various raw pet food ingredients.

  4. Emerging Cardiovascular Risk Research: Impact of Pets on Cardiovascular Risk Prevention.

    Science.gov (United States)

    Schreiner, Pamela J

    2016-02-01

    Animals interact with humans in multiple ways, including as therapy and service animals, commercially as livestock, as wildlife, and in zoos. But the most common interaction is as companion animals in our homes, with an estimated 180 million cats and dogs living in US households. While pet ownership has been reported to have many health benefits, the findings are inconsistent. Cardiovascular risk factors such as lipids, glucose, obesity, and heart rate variability have improved, worsened, or remained the same in the limited number of studies considering companion animals. Physical activity increases have more consistently been linked with dog ownership, although whether this reflects antecedent motivation or direct benefit from the dog is unclear. Allergies and asthma also are variably linked to pet ownership and are confounded by family history of atopy and timing of exposure to pet dander. The benefits of companion animals are most likely to be through reduction in depression, anxiety, and social isolation, but these studies have been largely cross-sectional and may depend on degree of bonding of the owner with the animal. Positive relationships show measurably higher oxytocin with lower cortisol and alpha-amylase levels. Finally, pet ownership is also a marker of better socioeconomic status and family stability, and if companion animals are to provide cardiovascular risk benefit, the route should perhaps be through improved education and opportunity for ownership.

  5. PET/CT in breast carcinoma, combined with sarcoidosis, imitating mediastinal lymph node metastases

    International Nuclear Information System (INIS)

    Garcheva, M.; Hadhyiska, V.; Bochev, P.

    2013-01-01

    PET/CT is a high sensitive, but low-specific method visualizing all the metabolic active processes. Fluoro-deoxyglucose (18F-FDG) uptake is high in tumors, as well as in infections, inflammations, granulomatous processes, post-radiotherapy alterations and in activated organs and tissues like brown fat, adrenals, thyroid, thymus, or bone marrow. This uptake can represent differential diagnostic problem. The clinical case is a young patient with invasive ductal and lobular breast carcinoma, after sectorial resection, without lymph node dissection. The chemotherapy was stopped after 3 courses due to thrombosis of vena cephalica. The local clinical status raises suspicion of recurrence, as the ultrasound. PET/CT was not conclusive about mediastinal lymph node involvement. The histology proves sarcoidosis, which frequently demonstrates symmetric 18F-FDG avid mediastinal and hilar lymph nodes. However the biopsy is mandatory, because of the low specificity of PET/CT for discrimination of this systemic disorder from tumor involvement. Keywords: PET/CT. Differential Diagnostic Problems

  6. PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner

    OpenAIRE

    Hirsch, Franz Wolfgang; Sattler, Bernhard; Sorge, Ina; Kurch, Lars; Viehweger, Adrian; Ritter, Lutz; Werner, Peter; Jochimsen, Thies; Barthel, Henryk; Bierbach, Uta; Till, Holger; Sabri, Osama; Kluge, Regine

    2013-01-01

    Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition ...

  7. [Pain therapy in small pets].

    Science.gov (United States)

    Tacke, Sabine; Gollwitzer, Andrea; Grammel, Lukas; Henke, Julia

    2017-02-09

    Although many advances in pain therapy have been made in recent years, pain therapy is more difficult in the small domestic animal than in cats and dogs. However, there is the ethical obligation that these animals also receive adequate pain therapy. An analgesic is rarely authorized for use in small pets, with pharmacological investigations often lacking and dosages frequently only determined empirically. The small size of the animals often requires a higher dose per kilogram bodyweight compared to cats and dogs. The dosage itself is also difficult to apply in small animals, because many analgesics must be diluted before their use. In addition, frequent manipulation of small animals for analgesic administration induces stress in the patient, which can intensify the pain. In the present article, those analgesics suitable for use in the small domestic animal are described and the indications for the use of the various types of analgesics are explained. A specialized section concentrates on pain detection and algesimetry in the small domestic animal. The detection of pain is much more difficult in small domestic animals. In the last few years so-called "grimace scales" have been developed which are used to assess the facial expression of the animals.

  8. CSF biomarkers of Alzheimer's disease concord with amyloid-β PET and predict clinical progression: A study of fully automated immunoassays in BioFINDER and ADNI cohorts.

    Science.gov (United States)

    Hansson, Oskar; Seibyl, John; Stomrud, Erik; Zetterberg, Henrik; Trojanowski, John Q; Bittner, Tobias; Lifke, Valeria; Corradini, Veronika; Eichenlaub, Udo; Batrla, Richard; Buck, Katharina; Zink, Katharina; Rabe, Christina; Blennow, Kaj; Shaw, Leslie M

    2018-03-01

    We studied whether fully automated Elecsys cerebrospinal fluid (CSF) immunoassay results were concordant with positron emission tomography (PET) and predicted clinical progression, even with cutoffs established in an independent cohort. Cutoffs for Elecsys amyloid-β 1-42 (Aβ), total tau/Aβ(1-42), and phosphorylated tau/Aβ(1-42) were defined against [ 18 F]flutemetamol PET in Swedish BioFINDER (n = 277) and validated against [ 18 F]florbetapir PET in Alzheimer's Disease Neuroimaging Initiative (n = 646). Clinical progression in patients with mild cognitive impairment (n = 619) was studied. CSF total tau/Aβ(1-42) and phosphorylated tau/Aβ(1-42) ratios were highly concordant with PET classification in BioFINDER (overall percent agreement: 90%; area under the curve: 94%). The CSF biomarker statuses established by predefined cutoffs were highly concordant with PET classification in Alzheimer's Disease Neuroimaging Initiative (overall percent agreement: 89%-90%; area under the curves: 96%) and predicted greater 2-year clinical decline in patients with mild cognitive impairment. Strikingly, tau/Aβ ratios were as accurate as semiquantitative PET image assessment in predicting visual read-based outcomes. Elecsys CSF biomarker assays may provide reliable alternatives to PET in Alzheimer's disease diagnosis. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Parallel ICA of FDG-PET and PiB-PET in three conditions with underlying Alzheimer's pathology.

    Science.gov (United States)

    Laforce, Robert; Tosun, Duygu; Ghosh, Pia; Lehmann, Manja; Madison, Cindee M; Weiner, Michael W; Miller, Bruce L; Jagust, William J; Rabinovici, Gil D

    2014-01-01

    The relationships between clinical phenotype, β-amyloid (Aβ) deposition and neurodegeneration in Alzheimer's disease (AD) are incompletely understood yet have important ramifications for future therapy. The goal of this study was to utilize multimodality positron emission tomography (PET) data from a clinically heterogeneous population of patients with probable AD in order to: (1) identify spatial patterns of Aβ deposition measured by ((11)C)-labeled Pittsburgh Compound B (PiB-PET) and glucose metabolism measured by FDG-PET that correlate with specific clinical presentation and (2) explore associations between spatial patterns of Aβ deposition and glucose metabolism across the AD population. We included all patients meeting the criteria for probable AD (NIA-AA) who had undergone MRI, PiB and FDG-PET at our center (N = 46, mean age 63.0 ± 7.7, Mini-Mental State Examination 22.0 ± 4.8). Patients were subclassified based on their cognitive profiles into an amnestic/dysexecutive group (AD-memory; n = 27), a language-predominant group (AD-language; n = 10) and a visuospatial-predominant group (AD-visuospatial; n = 9). All patients were required to have evidence of amyloid deposition on PiB-PET. To capture the spatial distribution of Aβ deposition and glucose metabolism, we employed parallel independent component analysis (pICA), a method that enables joint analyses of multimodal imaging data. The relationships between PET components and clinical group were examined using a Receiver Operator Characteristic approach, including age, gender, education and apolipoprotein E ε4 allele carrier status as covariates. Results of the first set of analyses independently examining the relationship between components from each modality and clinical group showed three significant components for FDG: a left inferior frontal and temporoparietal component associated with AD-language (area under the curve [AUC] 0.82, p = 0.011), and two components associated with

  10. Noninvasive 89Zr-Transferrin PET Shows Improved Tumor Targeting Compared with 18F-FDG PET in MYC-Overexpressing Human Triple-Negative Breast Cancer.

    Science.gov (United States)

    Henry, Kelly E; Dilling, Thomas R; Abdel-Atti, Dalya; Edwards, Kimberly J; Evans, Michael J; Lewis, Jason S

    2018-01-01

    The current standard for breast PET imaging is 18 F-FDG. The heterogeneity of 18 F-FDG uptake in breast cancer limits its utility, varying greatly among receptor status, histopathologic subtypes, and proliferation markers. 18 F-FDG PET often exhibits nonspecific internalization and low specificity and sensitivity, especially with tumors smaller than 1 cm 3 MYC is a protein involved in oncogenesis and is overexpressed in triple-negative breast cancer (TNBC). Increased surface expression of transferrin receptor (TfR) is a downstream event of MYC upregulation and has been validated as a clinically relevant target for molecular imaging. Transferrin labeled with 89 Zr has successfully identified MYC status in many cancer subtypes preclinically and been shown to predict response and changes in oncogene status via treatment with small-molecule inhibitors that target MYC and PI3K signaling pathways. We hypothesized that 89 Zr-transferrin PET will noninvasively detect MYC and TfR and improve upon the current standard of 18 F-FDG PET for MYC-overexpressing TNBC. Methods: In this study, 89 Zr-transferrin and 18 F-FDG imaging were compared in preclinical models of TNBC. TNBC cells (MDA-MB-157, MDA-MB-231, and Hs578T) were treated with bromodomain-containing protein 4 (BRD4) inhibitors JQ1 and OTX015 (0.5-1 μM). Cell proliferation, gene expression, and protein expression were assayed to explore the effects of these inhibitors on MYC and TfR. Results: Head-to-head comparison showed that 89 Zr-transferrin targets TNBC tumors significantly better ( P Myc and TfR gene expression was decreased upon treatment with BRD4 inhibitors and c-MYC small interfering RNA ( P MYC and TfR protein expression, along with receptor-mediated internalization of transferrin, was also significantly decreased upon drug treatment in MDA-MB-231 and MDA-MB-157 cells ( P MYC via TfR-targeted PET imaging in TNBC. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  11. Direct comparison of [18F]FDG PET/CT with PET alone and with side-by-side PET and CT in patients with malignant melanoma

    International Nuclear Information System (INIS)

    Mottaghy, Felix M.; Wohlfart, Petra; Blumstein, Norbert M.; Neumaier, Bernd; Glatting, Gerhard; Buck, Andreas K.; Reske, Sven N.; Sunderkoetter, Cord; Schubert, Roland; Oezdemir, Cueneyt; Scharfetter-Kochanek, Karin

    2007-01-01

    The purpose of this retrospective, blinded study was to evaluate the additional value of [ 18 F]FDG PET/CT in comparison with PET alone and with side-by-side PET and CT in patients with malignant melanoma (MM). A total of 127 consecutive studies of patients with known MM referred for a whole-body PET/CT examination were included in this study. PET alone, side-by-side PET and CT and integrated PET/CT study were independently and separately interpreted without awareness of the clinical information. One score each was applied for certainty of lesion localisation and for certainty of lesion characterisation. Verification of the findings was subsequently performed using all available clinical, pathological (n = 30) and follow-up information. The number of lesions with an uncertain localisation was significantly (p 18 F]FDG. (orig.)

  12. PET application in psychiatry and psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Suhara, Tetsuya [National Inst. of Radiological Sciences, Chiba (Japan)

    1999-07-01

    In the last few decades diagnostic and research tools in the medical field have made great advances, yet psychiatry has lacked sufficiently sensitive tools to measure the aberration of brain functions. Recently however, the development of Positron emission tomography (PET) techniques has made it possible to measure changes in neurochemical components in mental disorders and the effect of psychoactive drugs in living human brain. Most of the advancement in the psychiatric field has came from the development psychoactive drugs. Brain research involving identification of neurotransmission is largely based on compounds developed in psychopharmacology. Some of these compounds have been radiolabelled and used as radioligands for quantitative examination of neuroreceptors and other aspects of neurotransmission. Using PET, radioligand binding can now be examined in the human brain in vivo. PET techniques also allow examination of an unlabelled drug by examination of its interaction with a radioligand. So one potential of PET in psychiatry is to investigate the mechanism of psychoactive drugs. Antidepressants modulate serotonin transmission by inhibiting serotonin reuptake from the synaptic cleft. High affinity [{sup 3}H]imipramine binding sites in mammalian brain have been labelled to investigate serotonin transporters in living human brain by PET. Cyanoimipramine which is described as a potent serotonin reuptake inhibitor, was labelled with {sup 11}C. In a PET experiment with 6 healthy human subjects, a high accumulation of [{sup 11}C]cyanoimipramine was found in the thalamus and striatum and lowest accumulation was observed in the cerebellum, a region relatively void of serotonin transporters. The thalamus to cerebellum ratio was about 2 at 90 min after the injection of the tracer. Recently, [{sup 11}C]McN5652-X has been introduced as a better tracer for serotonin transporter imaging. Employing [{sup 11}C]McN5652-X in a PET study of 7 healthy human subjects, a high

  13. Importance of PET/CT in lymphoma diagnostics; Stellenwert der PET/CT in der Lymphomdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, A.; Kratochwil, C.; Haberkorn, U.; Giesel, F.L. [Universitaetsklinikum Heidelberg, Abteilung fuer Nuklearmedizin, Radiologische Klinik, Heidelberg (Germany)

    2012-04-15

    Staging or re-staging of lymphomas using conventional imaging modalities is based on morphological changes, usually on the diameter of lesions. However, vitality of tumors cannot be evaluated. In this context computed tomography (CT) has been used as a standard modality. Since the introduction of positron emission tomography (PET), evaluation of tumor vitality has become possible. Moreover PET/CT hybrid scanners were brought onto the market one decade ago. The fluorodeoxyglucose (FDG) PET/CT technique is now accepted as one of the most accurate modalities in the diagnosis of aggressive lymphomas due to a high FDG uptake (overall accuracy > 90%, sensitivity >90%). However, indolent lymphomas suffer from lower FDG uptake due to a moderate metabolic activity. After the introduction of PET/CT hybrid imaging the specificity of this diagnostic technique increased significantly compared to PET alone (from > 80% to > 90%). With the utilization of PET approximately 20% more lesions are detected when comparing to CT alone and in up to 15% of the patients this also results in a change of the therapeutic regime. As post-chemotherapy scar tissue usually persists for months, evaluation of vitality within residual bulks using FDG-PET can predict therapy response much earlier than CT, enabling therapy stratification. Other PET tracers apart from FDG have low impact in imaging of lymphomas and only the thymidine analogue fluorothymidine (FLT) is used in some cases for non-invasive measurement of proliferation. Despite the capability of FDG-PET/CT there is no evidence that the improvement in diagnostics is translated into a better patient outcome and therefore warrants the high costs. False positive findings in PET can result in unnecessary treatment escalation with subsequent higher therapy-associated toxicity and costs. Some pitfalls can be avoided by scheduling PET scans carefully. As treatment-induced inflammation early after therapy can be misinterpreted as vital tumor tissue

  14. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  15. Evaluation of various hepatic lesions with PET

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chul Ju

    2000-12-01

    When a liver lesion is found in a PET image, differential diagnosis and analysis of the lesion is very important. We tried to analyze hepatic lesions found in PET. 53 patients with focal liver lesions (13 patients with HCC, 8 patients with cholangiocarcinoma (CC), 20 patients with liver metastasis, 5 patients with hemangioma, 7 patients with liver abscess, including 1 patient with liver candidiasis) were examined. Definitely high FDG uptake pattern were observed in 54% (7/13) of HCC, 100% (8/8) of CC, 95% (19/20) of metastatic liver cancer and 100% (7/7) of liver abscess. Therefore, PET was partially useful in the diagnosis of HCC, but it was very useful in the diagnosis of CC or liver metastasis or liver abscess. The contrast between lesions and surrounding liver background was very conspicuous in PET images of CC or liver metastasis or liver abscess, which suggests that PET might be used for the follow up and assessment of treatment response of these diseases.

  16. Evaluation of various hepatic lesions with PET

    International Nuclear Information System (INIS)

    Han, Chul Ju

    2000-12-01

    When a liver lesion is found in a PET image, differential diagnosis and analysis of the lesion is very important. We tried to analyze hepatic lesions found in PET. 53 patients with focal liver lesions (13 patients with HCC, 8 patients with cholangiocarcinoma (CC), 20 patients with liver metastasis, 5 patients with hemangioma, 7 patients with liver abscess, including 1 patient with liver candidiasis) were examined. Definitely high FDG uptake pattern were observed in 54% (7/13) of HCC, 100% (8/8) of CC, 95% (19/20) of metastatic liver cancer and 100% (7/7) of liver abscess. Therefore, PET was partially useful in the diagnosis of HCC, but it was very useful in the diagnosis of CC or liver metastasis or liver abscess. The contrast between lesions and surrounding liver background was very conspicuous in PET images of CC or liver metastasis or liver abscess, which suggests that PET might be used for the follow up and assessment of treatment response of these diseases

  17. Injuries, envenomations and stings from exotic pets.

    Science.gov (United States)

    Warwick, Clifford; Steedman, Catrina

    2012-07-01

    A variety of exotic vertebrate and invertebrate species are kept as 'pets' including fishes, amphibians (for example, frogs and toads), reptiles (turtles, crocodiles, lizards and snakes), birds, mammals (for example, primates, civets, and lions), and invertebrates (for example spiders, scorpions, and centipedes), and ownership of some of these animals is rising. Data for 2009-2011 suggest that the number of homes with reptiles rose by approximately 12.5%. Recent surveys, including only some of these animals, indicated that they might be present in around 18.6% of homes (equal to approximately 42 million animals of which around 40 million are indoor or outdoor fish). Many exotic 'pets' are capable of causing injury or poisoning to their keepers and some contacts prove fatal. We examined NHS Health Episode Statistics for England using selected formal categories for hospital admissions and bed days for 2004-2010 using the following categories of injury, envenomation or sting; bitten or struck by crocodile or alligator; bitten or crushed by other reptiles: contact with venomous snakes and lizards; contact with scorpions. Between 2004 and 2010 these data conservatively show a total of 760 full consultation episodes, 709 admissions and 2,121 hospital bed days were associated with injuries probably from exotic pets. Injuries, envenomations and stings from exotic pets constitute a small but important component of emerging medical problems. Greater awareness of relevant injuries and medical sequelae from exotic pet keeping may help medics formulate their clinical assessment and advice to patients.

  18. EUV micropatterning for biocompatibility control of PET

    Science.gov (United States)

    Reisinger, B.; Fahrner, M.; Frischauf, I.; Yakunin, S.; Svorcik, V.; Fiedorowicz, H.; Bartnik, A.; Romanin, C.; Heitz, J.

    2010-08-01

    We have investigated the influence of oriented microstructures at modified polyethylene terephthalate (PET) on the adhesion and alignment of Chinese hamster ovary (CHO) cells. For surface modification, the PET foils were exposed to the radiation of a laser-plasma extreme ultraviolet (EUV) source based on a double-stream gas-puff target. The emission of the plasma was focused onto the samples by means of a gold-plated ellipsoidal collector. The spectrum of the focused radiation covered the wavelength range from 9 to 70 nm. The PET samples were irradiated with the EUV pulses at a repetition rate of 10 Hz in a high vacuum. For control experiments, PET samples were also irradiated in air with the light of a 193 nm ArF-excimer laser. Different kinds of surface microstructures were obtained depending on the EUV or laser fluence and pulse number, including oriented wall- and ripple-type structures with lateral structure periods of a few µm. The surface morphology of polymer samples after the irradiation was investigated using a scanning electron microscope (SEM). Changes in chemical surface structure of the irradiated samples were investigated using X-ray photoelectron spectroscopy (XPS). We demonstrated that the cells show good adhesion and align along oriented wall- and ripple-type microstructures on PET surfaces produced by the EUV irradiation.

  19. Properties of PET/PLA Electrospun Blends

    Science.gov (United States)

    Li, Kevin; Cebe, Peggy

    2012-02-01

    Electrospun membranes were fabricated from poly(ethylene terephthalate), PET, co-spun with poly(lactic acid), PLA. The PLA contained 2% of the D-isomer, which served to limit the overall degree of crystallinity. Membranes were deposited from blended solutions of PET/PLA in hexafluoroisopropanol. The PET/PLA composition ranged from 0/100, 75/25, 50/50, 25/75, and 100/0. Electrospun membranes were made using either a static flat plate or a rotating wheel as the counter electrode, yielding unoriented mats or highly oriented tapes, respectively. We report on our investigation of the crystallinity, crystal perfection, and mechanical properties of these materials using differential scanning calorimetry, wide and small angle X-ray scattering, and dynamic mechanical analysis. In particular, we study the ability of one blend component (PET) to crystallize in the presence of existing crystals of the second blend component (PLA) which crystallizes first and at a lower temperature than PET.

  20. Positron Emission Tomography (PET) in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Gallamini, Andrea, E-mail: gallamini.a@ospedale.cuneo.it [Department of Research and Medical Innovation, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Zwarthoed, Colette [Department of Nuclear Medicine, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Borra, Anna [Hematology Department S. Croce Hospital, Via M. Coppino 26, Cuneo 12100 (Italy)

    2014-09-29

    Since its introduction in the early nineties as a promising functional imaging technique in the management of neoplastic disorders, FDG-PET, and subsequently FDG-PET/CT, has become a cornerstone in several oncologic procedures such as tumor staging and restaging, treatment efficacy assessment during or after treatment end and radiotherapy planning. Moreover, the continuous technological progress of image generation and the introduction of sophisticated software to use PET scan as a biomarker paved the way to calculate new prognostic markers such as the metabolic tumor volume (MTV) and the total amount of tumor glycolysis (TLG). FDG-PET/CT proved more sensitive than contrast-enhanced CT scan in staging of several type of lymphoma or in detecting widespread tumor dissemination in several solid cancers, such as breast, lung, colon, ovary and head and neck carcinoma. As a consequence the stage of patients was upgraded, with a change of treatment in 10%–15% of them. One of the most evident advantages of FDG-PET was its ability to detect, very early during treatment, significant changes in glucose metabolism or even complete shutoff of the neoplastic cell metabolism as a surrogate of tumor chemosensitivity assessment. This could enable clinicians to detect much earlier the effectiveness of a given antineoplastic treatment, as compared to the traditional radiological detection of tumor shrinkage, which usually takes time and occurs much later.

  1. Fully 3D GPU PET reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J.L., E-mail: joaquin@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cal-Gonzalez, J. [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Vaquero, J.J. [Departmento de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Desco, M. [Departmento de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Fully 3D iterative tomographic image reconstruction is computationally very demanding. Graphics Processing Unit (GPU) has been proposed for many years as potential accelerators in complex scientific problems, but it has not been used until the recent advances in the programmability of GPUs that the best available reconstruction codes have started to be implemented to be run on GPUs. This work presents a GPU-based fully 3D PET iterative reconstruction software. This new code may reconstruct sinogram data from several commercially available PET scanners. The most important and time-consuming parts of the code, the forward and backward projection operations, are based on an accurate model of the scanner obtained with the Monte Carlo code PeneloPET and they have been massively parallelized on the GPU. For the PET scanners considered, the GPU-based code is more than 70 times faster than a similar code running on a single core of a fast CPU, obtaining in both cases the same images. The code has been designed to be easily adapted to reconstruct sinograms from any other PET scanner, including scanner prototypes.

  2. Rol del PET/CT en epilepsia

    Directory of Open Access Journals (Sweden)

    Dr. Ladrón De Guevara David

    2013-11-01

    Full Text Available El PET (Positron Emission Tomography con F18-Fluorodeoxiglucosa (FDG es un examen ampliamente utilizado en el estudio de epilepsia refractaria, constituyendo en la actualidad un pilar fundamental en la evaluación quirúrgica. El PET proporciona una traducción funcional de la lesión morfológica y puede pesquisar otras áreas epileptógenas temporales y extratemporales no visibles con los métodos tradicionales. Su alta sensibilidad y positividad aún con Resonancia Magnética (RM negativa, hace posible optar a la resección quirúrgica en pacientes que de otra manera no podrían operarse, obteniendo sujetos libres de crisis en hasta el 80% de las epilepsias temporales. El PET es realizado eminentemente en fase interictal y posee una sensibilidad de 90% en focos temporales y 50 a 70% en focos extratemporales. El PET “ictal” y el uso de radiofármacos distintos del F18-FDG son alternativas válidas en ciertos casos de epilepsia, especialmente extratemporal. Es posible que el uso del PET en epilepsia siga aumentando debido a la cada vez mayor disponibilidad del método y su consiguiente menor costo.

  3. Human salmonellosis associated with exotic pets.

    Science.gov (United States)

    Woodward, D L; Khakhria, R; Johnson, W M

    1997-11-01

    During the period from 1994 to 1996, an increase in the number of laboratory-confirmed cases of human salmonellosis associated with exposure to exotic pets including iguanas, pet turtles, sugar gliders, and hedgehogs was observed in Canada. Pet turtle-associated salmonellosis was recognized as a serious public health problem in the 1960s and 1970s, and in February 1975 legislation banning the importation of turtles into Canada was enacted by Agriculture Canada. Reptile-associated salmonellosis is once again being recognized as a resurgent disease. From 1993 to 1995, there were more than 20,000 laboratory-confirmed human cases of salmonellosis in Canada. The major source of Salmonella infection is food; however, an estimated 3 to 5% of all cases of salmonellosis in humans are associated with exposure to exotic pets. Among the isolates from these patients with salmonellosis, a variety of Salmonella serotypes were also associated with exotic pets and included the following: S. java, S. stanley, S. poona, S. jangwani, S. tilene, S. litchfield, S. manhattan, S. pomona, S. miami, S. rubislaw, S. marina subsp. IV, and S. wassenaar subsp. IV.

  4. Infectious threats from exotic pets: dermatological implications.

    Science.gov (United States)

    Rosen, Ted; Jablon, Jennifer

    2003-04-01

    Zoonoses are diseases that can be transmitted from animals to humans. More than 250 distinct zoonoses have been described in the literature. It is estimated that 56% of United States households contain at least one pet, and although considerable research has been performed regarding the more common household animals including dogs, cats, small birds, and rodents, surprisingly little is known about the zoonotic hazards of owning the more exotic pets. According to the 1997 USPHS/IDSA Report on the Prevention of Opportunistic Infections in Persons Infected with Human Immunodeficiency Virus, the immunocompromised patient should avoid contact with feces-laden soil, litter boxes, reptiles, most pet birds, and any animal less than 6 months old . It has also been documented that because of their inquisitive nature, children are at even higher risk for infection from animals than adolescents or immunocompetent adults. In this article the authors have reviewed the available data regarding hazards associated with the hedgehog, flying squirrel, iguana, chinchilla, and cockatoo. With the growing popularity of such exotic pets, further observation and research is warranted. Physicians need to be aware of the possibility of zoonotic disease related to exotic pet ownership, and they should address this issue when obtaining a history and formulating a differential diagnosis of cutaneous lesions suggestive of such illnesses.

  5. Development of HM12 cyclotron for PET

    International Nuclear Information System (INIS)

    Morita, Takuzo; Kawama, Tetsuo; Fujii, Kazuo

    2000-01-01

    In Japan, there are at present more than 30 PET (Positron Emission Tomography) facilities. The movements of medical insurance application to the PET diagnosis using [ 18 F] FDG (2-[ 18 F]-fluoro-2-deoxy-glucose) by the Ministry of Health and Welfare are being enhanced by PET related people. Therefore, more clinical centers using PET system are expected to be built in the near future. HM12 cyclotron was developed to meet such market demands for PET, and the prototype machine has been rent to Cyclotron Radio Isotope Center (CYRIC) of Tohoku University since Oct. 1998 for their use of clinical research with positron emitters like 11 C, 13 N, 15 O and 18 F. We got many technical data of HM12 Cyclotron on the clinical base. The data was enough to establish the reliability of HM12 system operation under the clinical condition. The first commercial product of HM12 Cyclotron was delivered to National Cancer Center in March 2000. The final performance test will be finished by the end of June 2000. (author)

  6. Clinical PET/MRI in neurooncology

    DEFF Research Database (Denmark)

    Marner, Lisbeth; Henriksen, Otto M; Lundemann, Michael

    2017-01-01

    PURPOSE: Magnetic resonance imaging (MRI) plays a key role in neurooncology, i.e., for diagnosis, treatment evaluation and detection of recurrence. However, standard MRI cannot always separate malignant tissue from other pathologies or treatment-induced changes. Advanced MRI techniques such as di...... treatment changes, although sequential same-day imaging on separate systems will often constitute a reliable and cost-effective alternative. Pediatric patients who require general anesthesia will benefit the most from simultaneous PET and MR imaging....... such as diffusion-weighted imaging, perfusion imaging and spectroscopy show promising results in discriminating malignant from benign lesions. Further, supplemental imaging with amino acid positron emission tomography (PET) has been shown to increase accuracy significantly and is used routinely at an increasing...... number of sites. Several centers are now implementing hybrid PET/MRI systems allowing for multiparametric imaging, combining conventional MRI with advanced MRI and amino acid PET imaging. Neurooncology is an obvious focus area for PET/MR imaging. METHODS: Based on the literature and our experience from...

  7. ChIA-PET2: a versatile and flexible pipeline for ChIA-PET data analysis.

    Science.gov (United States)

    Li, Guipeng; Chen, Yang; Snyder, Michael P; Zhang, Michael Q

    2017-01-09

    ChIA-PET2 is a versatile and flexible pipeline for analyzing different types of ChIA-PET data from raw sequencing reads to chromatin loops. ChIA-PET2 integrates all steps required for ChIA-PET data analysis, including linker trimming, read alignment, duplicate removal, peak calling and chromatin loop calling. It supports different kinds of ChIA-PET data generated from different ChIA-PET protocols and also provides quality controls for different steps of ChIA-PET analysis. In addition, ChIA-PET2 can use phased genotype data to call allele-specific chromatin interactions. We applied ChIA-PET2 to different ChIA-PET datasets, demonstrating its significantly improved performance as well as its ability to easily process ChIA-PET raw data. ChIA-PET2 is available at https://github.com/GuipengLi/ChIA-PET2. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. Caring for Pets When You're Pregnant

    Science.gov (United States)

    ... t feed your cat undercooked meat. Are hamsters, guinea pigs and mice safe pets to have when you’ ... Many peoples have rodents, including mice, hamsters and guinea pigs, as pets. If you’re pregnant or planning ...

  9. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  10. Breast cancer detection using high-resolution breast PET compared to whole-body PET or PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kalinyak, Judith E. [Naviscan Inc., San Diego, CA (United States); Berg, Wendie A. [University of Pittsburgh School of Medicine, Magee-Womens Hospital, Pittsburgh, PA (United States); Schilling, Kathy [Boca Raton Regional Hospital, Boca Raton, FL (United States); Madsen, Kathleen S. [Certus International, Inc., St. Louis, MO (United States); Narayanan, Deepa [Naviscan Inc., San Diego, CA (United States); National Cancer Institute, Bethesda, MD (United States); Tartar, Marie [Scripps Clinic, Scripps Green Hospital, La Jolla, CA (United States)

    2014-02-15

    To compare the performance characteristics of positron emission mammography (PEM) with those of whole-body PET (WBPET) and PET/CT in women with newly diagnosed breast cancer. A total of 178 women consented to PEM for presurgical planning in an IRB-approved protocol and also underwent either WBPET (n = 69) or PET/CT (n = 109) imaging, as per usual care at three centers. Tumor detection sensitivity, positive predictive values, and {sup 18}F-fluorodeoxyglucose (FDG) uptake were compared between the modalities. The effects of tumor size, type, and grade on detection were examined. The chi-squared or Fisher's exact tests were used to compare distributions between groups, and McNemar's test was used to compare distributions for paired data within subject groups, i.e. PEM versus WBPET or PEM versus PET/CT. The mean age of the women was 59 ± 12 years (median 60 years, range 26-89 years), with a mean invasive index tumor size of 1.6 ± 0.8 cm (median 1.5 cm, range 0.5-4.0 cm). PEM detected more index tumors (61/66, 92 %) than WBPET (37/66, 56 %; p < 0.001) or PET/CT (95/109, 87 % vs. 104/109, 95 % for PEM; p < 0.029). Sensitivity for the detection of additional ipsilateral malignancies was also greater with PEM (7/15, 47 %) than with WBPET (1/15, 6.7 %; p = 0.014) or PET/CT (3/23, 13 % vs. 13/23, 57 % for PEM; p = 0.003). Index tumor detection decreased with decreasing invasive tumor size for both WBPET (p = 0.002) and PET/CT (p < 0.001); PEM was not significantly affected (p = 0.20). FDG uptake, quantified in terms of maximum PEM uptake value, was lowest in ductal carcinoma in situ (median 1.5, range 0.7-3.0) and invasive lobular carcinoma (median 1.5, range 0.7-3.4), and highest in grade III invasive ductal carcinoma (median 3.1, range 1.4-12.9). PEM was more sensitive than either WBPET or PET/CT in showing index and additional ipsilateral breast tumors and remained highly sensitive for tumors smaller than 1 cm. (orig.)

  11. Transmission of Bacterial Zoonotic Pathogens between Pets and Humans: The Role of Pet Food.

    Science.gov (United States)

    Lambertini, Elisabetta; Buchanan, Robert L; Narrod, Clare; Pradhan, Abani K

    2016-01-01

    Recent Salmonella outbreaks associated with dry pet food and treats raised the level of concern for these products as vehicle of pathogen exposure for both pets and their owners. The need to characterize the microbiological and risk profiles of this class of products is currently not supported by sufficient specific data. This systematic review summarizes existing data on the main variables needed to support an ingredients-to-consumer quantitative risk model to (1) describe the microbial ecology of bacterial pathogens in the dry pet food production chain, (2) estimate pet exposure to pathogens through dry food consumption, and (3) assess human exposure and illness incidence due to contact with pet food and pets in the household. Risk models populated with the data here summarized will provide a tool to quantitatively address the emerging public health concerns associated with pet food and the effectiveness of mitigation measures. Results of such models can provide a basis for improvements in production processes, risk communication to consumers, and regulatory action.

  12. Does owning a pet protect older people against loneliness?

    OpenAIRE

    Pikhartova, Jitka; Bowling, Ann; Victor, Christina

    2014-01-01

    BackgroundPet ownership is thought to make a positive contribution to health, health behaviours and the general well-being of older people. More specifically pet ownership is often proposed as a solution to the problem of loneliness in later life and specific ‘pet based’ interventions have been developed to combat loneliness. However the evidence to support this relationship is slim and it is assumed that pet ownership is a protection against loneliness rather than a response to loneliness. T...

  13. 9 CFR 130.10 - User fees for pet birds.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for pet birds. 130.10... AGRICULTURE USER FEES USER FEES § 130.10 User fees for pet birds. (a) User fees for pet birds of U.S. origin returning to the United States, except pet birds of U.S. origin returning from Canada, are as follows...

  14. PET/MRI and PET/CT in Lung Lesions and Thoracic Malignancies.

    Science.gov (United States)

    Flechsig, Paul; Mehndiratta, Amit; Haberkorn, Uwe; Kratochwil, Clemens; Giesel, Frederik L

    2015-07-01

    More than one decade ago, introduction of integrated PET/CT scanners changed oncologic imaging and oncologic patient management profoundly. With these systems, the metabolic information acquired by PET can be anatomically localized even to small structures such as small primary tumors, lymph nodes, and soft tissue masses owing to the high-resolution multidetector CT scanners. This has made PET/CT a most reliable method for tumor detection, characterization, staging, and response monitoring. The importance of an integrated functional and morphologic approach to better understand the biology of oncologic disease and to improve therapy planning is underlined by the increasing number of PET/CT systems worldwide, leading to an increasing number of scientific publications in the field. The paradigmatic indication of integrated PET/CT is staging of patients with lung cancer, as PET/CT allows for precise pretherapeutic staging and also posttreatment restaging according to the TNM criteria. The growing numbers of targeted therapy strategies in the fields of surgery, chemotherapy, and radiation therapy, which are adapted to dedicated tumor stages, require the exact classifications of each patient's tumor stage. In this context, whole-body examinations using integrated (18)F-FDG-PET/CT have been shown to reduce the side effects of futile invasive procedures and reduce additional costly staging procedures. In this review article, the diagnostic and therapeutic effects of PET/CT examinations are highlighted and compared with some competitive techniques such as scintigraphy, MRI, and, where possible, integrated PET/MRI. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Integrated boost IMRT with FET-PET-adapted local dose escalation in glioblastomas. Results of a prospective phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Piroth, M.D.; Pinkawa, M.; Holy, R. [RWTH Aachen University Hospital (Germany). Dept. of Radiation Oncology; Forschungszentrum Juelich GmbH (DE). Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain] (and others)

    2012-04-15

    Dose escalations above 60 Gy based on MRI have not led to prognostic benefits in glioblastoma patients yet. With positron emission tomography (PET) using [{sup 18}F]fluorethyl-L-tyrosine (FET), tumor coverage can be optimized with the option of regional dose escalation in the area of viable tumor tissue. In a prospective phase II study (January 2008 to December 2009), 22 patients (median age 55 years) received radiochemotherapy after surgery. The radiotherapy was performed as an MRI and FET-PET-based integrated-boost intensity-modulated radiotherapy (IMRT). The prescribed dose was 72 and 60 Gy (single dose 2.4 and 2.0 Gy, respectively) for the FET-PET- and MR-based PTV-FET{sub (72 Gy)} and PTV-MR{sub (60 Gy)}. FET-PET and MRI were performed routinely for follow-up. Quality of life and cognitive aspects were recorded by the EORTC-QLQ-C30/QLQ Brain20 and Mini-Mental Status Examination (MMSE), while the therapy-related toxicity was recorded using the CTC3.0 and RTOG scores. Median overall survival (OS) and disease-free survival (DFS) were 14.8 and 7.8 months, respectively. All local relapses were detected at least partly within the 95% dose volume of PTV-MR{sub (60 Gy)}. No relevant radiotherapy-related side effects were observed (excepted alopecia). In 2 patients, a pseudoprogression was observed in the MRI. Tumor progression could be excluded by FET-PET and was confirmed in further MRI and FET-PET imaging. No significant changes were observed in MMSE scores and in the EORTC QLQ-C30/QLQ-Brain20 questionnaires. Our dose escalation concept with a total dose of 72 Gy, based on FET-PET, did not lead to a survival benefit. Acute and late toxicity were not increased, compared with historical controls and published dose-escalation studies. (orig.)

  16. {sup 18}F-FDG PET/CT evaluation of children and young adults with suspected spinal fusion hardware infection

    Energy Technology Data Exchange (ETDEWEB)

    Bagrosky, Brian M. [University of Colorado School of Medicine, Department of Pediatric Radiology, Children' s Hospital Colorado, 12123 E. 16th Ave., Box 125, Aurora, CO (United States); University of Colorado School of Medicine, Department of Radiology, Division of Nuclear Medicine, Aurora, CO (United States); Hayes, Kari L.; Fenton, Laura Z. [University of Colorado School of Medicine, Department of Pediatric Radiology, Children' s Hospital Colorado, 12123 E. 16th Ave., Box 125, Aurora, CO (United States); Koo, Phillip J. [University of Colorado School of Medicine, Department of Radiology, Division of Nuclear Medicine, Aurora, CO (United States)

    2013-08-15

    Evaluation of the child with spinal fusion hardware and concern for infection is challenging because of hardware artifact with standard imaging (CT and MRI) and difficult physical examination. Studies using {sup 18}F-FDG PET/CT combine the benefit of functional imaging with anatomical localization. To discuss a case series of children and young adults with spinal fusion hardware and clinical concern for hardware infection. These people underwent FDG PET/CT imaging to determine the site of infection. We performed a retrospective review of whole-body FDG PET/CT scans at a tertiary children's hospital from December 2009 to January 2012 in children and young adults with spinal hardware and suspected hardware infection. The PET/CT scan findings were correlated with pertinent clinical information including laboratory values of inflammatory markers, postoperative notes and pathology results to evaluate the diagnostic accuracy of FDG PET/CT. An exempt status for this retrospective review was approved by the Institution Review Board. Twenty-five FDG PET/CT scans were performed in 20 patients. Spinal fusion hardware infection was confirmed surgically and pathologically in six patients. The most common FDG PET/CT finding in patients with hardware infection was increased FDG uptake in the soft tissue and bone immediately adjacent to the posterior spinal fusion rods at multiple contiguous vertebral levels. Noninfectious hardware complications were diagnosed in ten patients and proved surgically in four. Alternative sources of infection were diagnosed by FDG PET/CT in seven patients (five with pneumonia, one with pyonephrosis and one with superficial wound infections). FDG PET/CT is helpful in evaluation of children and young adults with concern for spinal hardware infection. Noninfectious hardware complications and alternative sources of infection, including pneumonia and pyonephrosis, can be diagnosed. FDG PET/CT should be the first-line cross-sectional imaging study in

  17. Bacterial Zoonoses Transmitted by Household Pets

    DEFF Research Database (Denmark)

    Damborg, Peter Panduro; Broens, E.M.; Chomel, B.B.

    2016-01-01

    with urine), and campylobacteriosis and salmonellosis (faecal–oral ingestion). Antimicrobial resistance was also included due to the recent emergence of multidrug-resistant bacteria of zoonotic potential in dogs and cats. There is a general lack of data on pathogen prevalence in the relevant pet population...... and on the incidence of human infections attributable to pets. In order to address these gaps in knowledge, and to minimize the risk of human infection, actions at several levels are recommended, including: (1) coordinated surveillance of zoonotic pathogens and antimicrobial resistance in household pets, (2) studies....... Disease-specific recommendations include incentives to undertake research aimed at the development of new diagnostic tests, veterinary-specific antimicrobial products and vaccines, as well as initiatives to promote best practices in veterinary diagnostic laboratories and prudent antimicrobial usage....

  18. [New pets, allergens and allergic dermatitis].

    Science.gov (United States)

    Brajon, D; Waton, J; Schmutz, J-L; Barbaud, A

    2014-10-01

    The number of household pets increased greatly during the twentieth century, with the numbers of new pets (NP, i.e. any pet other than cats and dogs) rising especially sharply over the last decade. Contact with such animals, whose owners do not always know how to look after them properly, expose the population to new risks such as trauma, infection and allergy. While the most common allergies are respiratory, allergic skin reactions, both immediate and delayed, may also result from contact with these new allergens. The animal itself or its environment may be the cause. Herein, we review NPs and reports of allergic dermatitis associated with them. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. FDG-PET/CT in lymphoma

    Directory of Open Access Journals (Sweden)

    Maria M D′souza

    2013-01-01

    Full Text Available Lymphomas are a heterogeneous group of diseases that arise from the constituent cells of the immune system or from their precursors. 18F-fludeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT is now the cornerstone of staging procedures in the state-of-the-art management of Hodgkin′s disease and aggressive non-Hodgkin′s lymphoma. It plays an important role in staging, restaging, prognostication, planning appropriate treatment strategies, monitoring therapy, and detecting recurrence. However, its role in indolent lymphomas is still unclear and calls for further investigational trials. The protean PET/CT manifestations of lymphoma necessitate a familiarity with the spectrum of imaging findings to enable accurate diagnosis. A meticulous evaluation of PET/CT findings, an understanding of its role in the management of lymphomas, and knowledge of its limitations are mandatory for the optimal utilization of this technique.

  20. FDG-PET/CT in lymphoma

    International Nuclear Information System (INIS)

    D'souza, Maria M; Jaimini, Abhinav; Bansal, Abhishek; Tripathi, Madhavi; Sharma, Rajnish; Mondal, Anupam; Tripathi, Rajendra Prashad

    2013-01-01

    Lymphomas are a heterogeneous group of diseases that arise from the constituent cells of the immune system or from their precursors. 18F-fludeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is now the cornerstone of staging procedures in the state-of-the-art management of Hodgkin's disease and aggressive non-Hodgkin's lymphoma. It plays an important role in staging, restaging, prognostication, planning appropriate treatment strategies, monitoring therapy, and detecting recurrence. However, its role in indolent lymphomas is still unclear and calls for further investigational trials. The protean PET/CT manifestations of lymphoma necessitate a familiarity with the spectrum of imaging findings to enable accurate diagnosis. A meticulous evaluation of PET/CT findings, an understanding of its role in the management of lymphomas, and knowledge of its limitations are mandatory for the optimal utilization of this technique

  1. Automated radiochemical processing for clinical PET

    International Nuclear Information System (INIS)

    Padgett, H.C.; Kingsbury, W.G.

    1990-01-01

    The Siemens RDS 112, an automated radiochemical production and delivery system designed to support a clinical PET program, consists of an 11 MeV, proton only, negative ion cyclotron, a shield, a computer, and targetry and chemical processing modules to produce radiochemicals used in PET imaging. The principal clinical PET tracers are [ 18 F]FDG, [ 13 N]ammonia and [ 15 O]water. Automated synthesis of [ 18 F]FDG is achieved using the Chemistry Process Control Unit (CPCU), a general purpose valve-and-tubing device that emulates manual processes while allowing for competent operator intervention. Using function-based command file software, this pressure-driven synthesis system carries out chemical processing procedures by timing only, without process-based feedback. To date, nine CPCUs have installed at seven institutions resulting in 1,200+ syntheses of [ 18 F]FDG, with an average yield of 55% (EOB)

  2. Remote transfer of PET images by internet

    International Nuclear Information System (INIS)

    Zuo Chuantao; Lin Xiangtong; Guan Yihui; Zhao Jun

    2003-01-01

    The methodology of PET image remote transfer by Internet has been explored. The original images were got with ECAT EXACT HR + PET, and then converted to Dicom format by Mview software. The Dicom images were transferred via Internet. Thus the PET images were transferred via Internet successfully. The ideal images were obtained away from 8 km. The transfer time of brain and whole body image was (37±3)s and (245±10)s respectively, while the transfer rate was (34.7±2.8) kbyte/s and (34.4±1.5)kbyte/s, respectively. The results showed that the remote transfer via Internet was feasible and practical

  3. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  4. PET in malformations of cortical development

    International Nuclear Information System (INIS)

    Bouilleret, V.; O'Brien, T.J.; Bouilleret, V.; Bouilleret, V.; Chiron, C.; Chiron, C.

    2009-01-01

    Within the group of malformations of cortical development, focal cortical dysplasia (FCD) are an increasingly recognized cause of intractable epilepsy that can be cured by surgery. The success of cortical resection for intractable epilepsy is highly dependent on the accurate pre-surgical delineation of the regions responsible for generating seizures. [ 18 F]-FDG PET, which images cerebral metabolism studying brain glucose uptake, is the most established functional imaging modality in the evaluation of patients with epilepsy. The aim of this article is to review [ 18 F]-FDG PET usefulness as a pre-surgical tool in the evaluation of medically refractory partial epilepsy. It has an established place in assisting in the localisation and definition of FCD in patients with no lesion, or only a subtle abnormality, on MRI. The role of FDG-PET in defining the extent of the surgical resection is still uncertain and needs to be the focus of future research. (authors)

  5. Association between Responsible Pet Ownership and Glycemic Control in Youths with Type 1 Diabetes.

    Science.gov (United States)

    Maranda, Louise; Gupta, Olga T

    2016-01-01

    Type 1 diabetes mellitus (T1DM) a chronic characterized by an absolute insulin deficiency requires conscientious patient self-management to maintain glucose control within a normal range. Family cohesion and adaptability, positive coping strategies, social support and adequate self-regulatory behavior are found to favorably influence glycemic control. Our hypothesis was that the responsible care of a companion animal is associated with these positive attributes and correlated with the successful management of a chronic illness such as type 1 diabetes. We recruited 223 youths between 9 and 19 years of age from the Pediatric Diabetes clinic at the University of Massachusetts Medical School, reviewed the status of their glycemic control (using three consecutive A1c values) and asked them questions about the presence of a pet at home, and their level of involvement with its care. Multivariate analyses show that children who care actively for one or more pets at home are 2.5 times more likely to have control over their glycemic levels than children who do not care for a pet, adjusting for duration of disease, socio-economic status, age and self-management [1.1 to 5.8], pWald = 0.032. A separate model involving the care of a petdog only yielded comparable results (ORa = 2.6 [1.1 to 5.9], pWald = 0.023).

  6. Association between Responsible Pet Ownership and Glycemic Control in Youths with Type 1 Diabetes.

    Directory of Open Access Journals (Sweden)

    Louise Maranda

    Full Text Available Type 1 diabetes mellitus (T1DM a chronic characterized by an absolute insulin deficiency requires conscientious patient self-management to maintain glucose control within a normal range. Family cohesion and adaptability, positive coping strategies, social support and adequate self-regulatory behavior are found to favorably influence glycemic control. Our hypothesis was that the responsible care of a companion animal is associated with these positive attributes and correlated with the successful management of a chronic illness such as type 1 diabetes. We recruited 223 youths between 9 and 19 years of age from the Pediatric Diabetes clinic at the University of Massachusetts Medical School, reviewed the status of their glycemic control (using three consecutive A1c values and asked them questions about the presence of a pet at home, and their level of involvement with its care. Multivariate analyses show that children who care actively for one or more pets at home are 2.5 times more likely to have control over their glycemic levels than children who do not care for a pet, adjusting for duration of disease, socio-economic status, age and self-management [1.1 to 5.8], pWald = 0.032. A separate model involving the care of a petdog only yielded comparable results (ORa = 2.6 [1.1 to 5.9], pWald = 0.023.

  7. Ictal PET in presurgical workup of refractory extratemporal epilepsy

    Directory of Open Access Journals (Sweden)

    Javeria Nooraine

    2013-01-01

    Full Text Available Ictal Pet in presurgical workup of refractory epilepsy is seldom performed and limited due to technical difficulties. In carefully selected patient subset with frequent extratemporal seizures, ictal PET depicts ′seizure onset zone′ with high spatial resolution even within a widespread pathology. We here depict a four year old with posterior quadrant dysplasia evaluated with ictal PET.

  8. 50 CFR 14.17 - Personally owned pet birds.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Personally owned pet birds. 14.17 Section 14.17 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR... Ports § 14.17 Personally owned pet birds. Any person may import a personally owned pet bird at any port...

  9. Pet Care Teaching Unit: 1st-3rd Grades.

    Science.gov (United States)

    Peninsula Humane Society, San Mateo, CA.

    Activities in this unit are designed to familiarize primary grade students with the responsibilities involved in pet ownership. Teaching plans are provided for a total of 12 lessons involving social studies, language arts, math, and health sciences. Activities adaptable for readers and non-readers focus on pet overpopulation, care of pets when…

  10. Social capital and pet ownership - A tale of four cities.

    Science.gov (United States)

    Wood, Lisa; Martin, Karen; Christian, Hayley; Houghton, Steve; Kawachi, Ichiro; Vallesi, Shannen; McCune, Sandra

    2017-12-01

    Pet ownership is significantly associated with higher levels of social capital.•Social capital was associated with pet ownership in the U.S. and Australia.•Results are not confined to dog owners nor dog walkers.•Pets are an under-recognized conduit for building social capital.

  11. 50 CFR 36.36 - Sled dogs and household pets.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Sled dogs and household pets. 36.36... Sled dogs and household pets. The general trespass provisions of 50 CFR 26.21 shall not apply to household pets and sled, work, or pack dogs under the direct control of their owners or handlers, but such...

  12. The Psychological Effect of Pet-Ownership on Reading Achievement.

    Science.gov (United States)

    Hamtil, Rosemary

    A study examined the possible influence that pets may have on children's reading achievement. Subjects, 61 students from three third-grade classes in an urban school, completed a questionnaire about pet ownership. Responses were compiled and score values established to recognize the length of time the child had owned the pet and how much…

  13. SPECT and PET imaging in epilepsia; SPECT und PET in der Diagnostik von Epilepsien

    Energy Technology Data Exchange (ETDEWEB)

    Landvogt, C. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2007-09-15

    In preoperative localisation of epileptogenic foci, nuclear medicine diagnostics plays a crucial role. FDG-PET is used as first line diagnostics. In case of inconsistent MRI, EEG and FDG-PET findings, {sup 11}C-Flumazenil-PET or ictal and interictal perfusion-SPECT should be performed. Other than FDG, Flumazenil can help to identify the extend of the region, which should be resected. To enhance sensitivity and specificity, further data analysis using voxelbased statistical analyses or SISCOM (substraction ictal SPECT coregistered MRI) should be performed.

  14. PRODUCTION CONSIDERATIONS FOR THE CLASSICAL PET NUCLIDES

    International Nuclear Information System (INIS)

    FINN, R.; SCHLYER, D.

    2001-01-01

    Nuclear Medicine is the specialty of medical imaging, which utilizes a variety of radionuclides incorporated into specific compounds for diagnostic imaging and therapeutic applications. During recent years, research efforts associated with this discipline have concentrated on the decay characteristics of particular radionuclides and the design of unique radiolabeled tracers necessary to achieve time-dependent molecular images. The specialty is expanding with specific Positron emission tomography (PET) and SPECT radiopharmaceuticals allowing for an extension from functional process imaging in tissue to pathologic processes and nuclide directed treatments. PET is an example of a technique that has been shown to yield the physiologic information necessary for clinical oncology diagnoses based upon altered tissue metabolism. Most PET drugs are currently produced using a cyclotron at locations that are in close proximity to the hospital or academic center at which the radiopharmaceutical will be administered. In November 1997, a law was enacted called the Food and Drug Administration Modernization Act of 1997 which directed the Food and Drug Administration (FDA) to establish appropriate procedures for the approval of PET drugs in accordance with section 505 of the Federal Food, Drug, and Cosmetic Act and to establish current good manufacturing practice requirements for such drugs. At this time the FDA is considering adopting special approval procedures and cGMP requirements for PET drugs. The evolution of PET radiopharmaceuticals has introduced a new class of ''drugs'' requiring production facilities and product formulations that must be closely aligned with the scheduled clinical utilization. The production of the radionuclide in the appropriate synthetic form is but one critical component in the manufacture of the finished radiopharmaceutical

  15. PET imaging in patients with Modic changes

    Energy Technology Data Exchange (ETDEWEB)

    Albert, H.B.; Manniche, C. [Univ. of Southern Denmark, Funen (Denmark). Back Research Centre; Petersen, H.; Hoeilund-Carlsen, P.F. [Odense University Hospital, Univ. of Southern Denmark (Denmark). Dept. of Nuclear Medicine

    2009-07-01

    The aim of this study was via PET imaging to reveal if any highly metabolic processes were occurring in Modic changes type 1 and/or in the adjacent discs. Modic changes (MC) are signal changes in the vertebral endplate and body visualised by magnetic resonance imaging (MRI). MC are strongly associated with low back pain (LBP). MC type 1 appear to be inflammation on MRI, and histological and biochemical findings make it highly likely that an inflammation is present. Though MC is painful no known treatment is available, and it is unknown which entities affect the progress or regress of MC. The changes observed on MRI are slow and take months to develop, but faster changes in the metabolism might provide a platform for monitoring patients. Patients from The Back Centre Funen, with low back pain in the area of L1 to S1, MC type 1 in L1 to L5, and a previous herniated lumbar disc. All patients had a PET scan using FDG ({sup 18}F-fluorodeoxyglucose) as tracer. Included in the study were 11 patients, 4 women and 7 men, mean age 48.1 year (range 20-65). All MC were situated in the vertebrae both above and below the previously herniated disc/discs. Ten patients had MC at 1 level, and 1 had MC at 2 levels. The affected levels were 1 at L2/L3, 6 at L4 /L5, and 5 at L5/S1. All had a previous disc herniation and MC larger than 4 mm in diameter. Technically satisfactory PET scans were obtained. However, PET imaging showed no increases in metabolism in any vertebra or disc of any patient. Modic type 1 changes do not reveal themselves by showing increased metabolism with ordinary FDG PET imaging. PET tracers illuminating inflammation are being developed and hopefully may become more successful. (orig.)

  16. PET and SPECT imaging in veterinary medicine.

    Science.gov (United States)

    LeBlanc, Amy K; Peremans, Kathelijne

    2014-01-01

    Veterinarians have gained increasing access to positron emission tomography (PET and PET/CT) imaging facilities, allowing them to use this powerful molecular imaging technique for clinical and research applications. SPECT is currently being used more in Europe than in the United States and has been shown to be useful in veterinary oncology and in the evaluation of orthopedic diseases. SPECT brain perfusion and receptor imaging is used to investigate behavioral disorders in animals that have interesting similarities to human psychiatric disorders. This article provides an overview of the potential applications of PET and SPECT. The use of commercially available and investigational PET radiopharmaceuticals in the management of veterinary disease has been discussed. To date, most of the work in this field has utilized the commercially available PET tracer, (18)F-fluorodeoxyglucose for oncologic imaging. Normal biodistribution studies in several companion animal species (cats, dogs, and birds) have been published to assist in lesion detection and interpretation for veterinary radiologists and clinicians. Studies evaluating other (18)F-labeled tracers for research applications are underway at several institutions and companion animal models of human diseases are being increasingly recognized for their value in biomarker and therapy development. Although PET and SPECT technologies are in their infancy for clinical veterinary medicine, increasing access to and interest in these applications and other molecular imaging techniques has led to a greater knowledge and collective body of expertise for veterinarians worldwide. Initiation and fostering of physician-veterinarian collaborations are key components to the forward movement of this field. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. PET imaging in patients with Modic changes

    International Nuclear Information System (INIS)

    Albert, H.B.; Manniche, C.; Petersen, H.; Hoeilund-Carlsen, P.F.

    2009-01-01

    The aim of this study was via PET imaging to reveal if any highly metabolic processes were occurring in Modic changes type 1 and/or in the adjacent discs. Modic changes (MC) are signal changes in the vertebral endplate and body visualised by magnetic resonance imaging (MRI). MC are strongly associated with low back pain (LBP). MC type 1 appear to be inflammation on MRI, and histological and biochemical findings make it highly likely that an inflammation is present. Though MC is painful no known treatment is available, and it is unknown which entities affect the progress or regress of MC. The changes observed on MRI are slow and take months to develop, but faster changes in the metabolism might provide a platform for monitoring patients. Patients from The Back Centre Funen, with low back pain in the area of L1 to S1, MC type 1 in L1 to L5, and a previous herniated lumbar disc. All patients had a PET scan using FDG ( 18 F-fluorodeoxyglucose) as tracer. Included in the study were 11 patients, 4 women and 7 men, mean age 48.1 year (range 20-65). All MC were situated in the vertebrae both above and below the previously herniated disc/discs. Ten patients had MC at 1 level, and 1 had MC at 2 levels. The affected levels were 1 at L2/L3, 6 at L4 /L5, and 5 at L5/S1. All had a previous disc herniation and MC larger than 4 mm in diameter. Technically satisfactory PET scans were obtained. However, PET imaging showed no increases in metabolism in any vertebra or disc of any patient. Modic type 1 changes do not reveal themselves by showing increased metabolism with ordinary FDG PET imaging. PET tracers illuminating inflammation are being developed and hopefully may become more successful. (orig.)

  18. PRODUCTION CONSIDERATIONS FOR THE CLASSICAL PET NUCLIDES.

    Energy Technology Data Exchange (ETDEWEB)

    FINN,R.; SCHLYER,D.

    2001-06-25

    Nuclear Medicine is the specialty of medical imaging, which utilizes a variety of radionuclides incorporated into specific compounds for diagnostic imaging and therapeutic applications. During recent years, research efforts associated with this discipline have concentrated on the decay characteristics of particular radionuclides and the design of unique radiolabeled tracers necessary to achieve time-dependent molecular images. The specialty is expanding with specific Positron emission tomography (PET) and SPECT radiopharmaceuticals allowing for an extension from functional process imaging in tissue to pathologic processes and nuclide directed treatments. PET is an example of a technique that has been shown to yield the physiologic information necessary for clinical oncology diagnoses based upon altered tissue metabolism. Most PET drugs are currently produced using a cyclotron at locations that are in close proximity to the hospital or academic center at which the radiopharmaceutical will be administered. In November 1997, a law was enacted called the Food and Drug Administration Modernization Act of 1997 which directed the Food and Drug Administration (FDA) to establish appropriate procedures for the approval of PET drugs in accordance with section 505 of the Federal Food, Drug, and Cosmetic Act and to establish current good manufacturing practice requirements for such drugs. At this time the FDA is considering adopting special approval procedures and cGMP requirements for PET drugs. The evolution of PET radiopharmaceuticals has introduced a new class of ''drugs'' requiring production facilities and product formulations that must be closely aligned with the scheduled clinical utilization. The production of the radionuclide in the appropriate synthetic form is but one critical component in the manufacture of the finished radiopharmaceutical.

  19. Influence of PET/CT-introduction on PET scanning frequency and indications. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Eschmann, S.M.; Krause, B.J.; Roedel, R.; Tiling, R.; Weckesser, M.

    2007-01-01

    Aim: to evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: the study included all examinations performed on stand alone PET- or PET/CT-scanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: the overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: the introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry. (orig.)

  20. The effect of patient positioning aids on PET quantification in PET/MR imaging.

    Science.gov (United States)

    Mantlik, Frederic; Hofmann, Matthias; Werner, Matthias K; Sauter, Alexander; Kupferschläger, Jürgen; Schölkopf, Bernhard; Pichler, Bernd J; Beyer, Thomas

    2011-05-01

    Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation maps by following the same conversion procedure of the attenuation values except for the prior delineation and subtraction of the positioning aids from the CT images (modCT-AC). First, a uniform (68)Ge cylinder was positioned centrally in the PET/CT scanner and fixed with a vacuum mattress (10 cm thick) and, in a repeat examination, with MR positioning foam pads. Second, 16 patient datasets were selected for subsequent processing. All patients were regionally immobilized with positioning aids: a vacuum mattress for head/neck imaging (nine patients) and a foam mattress for imaging of the lower extremities (seven patients). PET images were reconstructed following CT-based attenuation and scatter correction using the original and modified (MR-like) CT images: PET(origCT-AC) and PET(modCT-AC), respectively. PET images following origCT-AC and modCT-AC were compared visually and in terms of mean differences of voxels with a standardized uptake value of at least 1.0. In addition, we report maximum activity concentration in lesions for selected patients. In the phantom study employing the vacuum mattress the average voxel activity in PET(modCT-AC) was underestimated by 6.4% compared to PET(origCT-AC), with 3

  1. Quantitative preclinical PET imaging: opportunities and challenges

    Directory of Open Access Journals (Sweden)

    Claudia eKuntner

    2014-02-01

    Full Text Available PET imaging of metabolism involves many choices, from hardware settings, software options to animal handling considerations. How to decide what settings or conditions to use is not straightforward, as the experimental design is dependent on the particular science being investigated. There is no single answer, yet there are factors that are common to all experiments that are the subject of this review. From physics to physiology, there are many factors to consider, each of which can have a significant impact upon measurements of metabolism in vivo. This review examines the most common factors related to all types of quantitative PET imaging.

  2. Pharmacological studies of the lung with PET

    International Nuclear Information System (INIS)

    Syrota, A.

    1986-10-01

    Positron emission tomography (PET), known to be used for lung ventilation and perfusion studies, can also be used in pharmacology to obtain information that is otherwise not available. The lung takes up biologically active substances which can be inactivated or activated, and synthesises and releases others. Such information in man has been obtained from samples of human lungs, or from in vivo first-pass studies, invasive or not, as well as from in vivo kinetic studies using external detection methods with scintillation cameras. PET provides now quantitative regional data in the human lung

  3. PET-Studies in parkinson's disease

    International Nuclear Information System (INIS)

    Schwarz, J.

    2002-01-01

    Positron-emission-tomography (PET) has enabled to study the metabolism and blood flow in specific brain areas. Besides, there is a variety of radiotracers that allow quantification of the function of distinct molecules. In respect to Parkinson's disease, PET allowed for the first time to assess the number of dopaminergic neurons in vivo. Thus, helping confirming a dopaminergic deficit, measuring disease progression and also help to determine the function of dopaminergic grafts. Current research has shifted to determine the role of related neurotransmitter systems in the pathophysiology of Parkinson's disease. (orig.) [de

  4. Detection of Mycobacterium avium in pet birds

    Science.gov (United States)

    Godoy, Silvia Neri; Sakamoto, Sidnei Miyoshi; de Paula, Cátia Dejuste; Catão-Dias, José Luiz; Matushima, Eliana Reiko

    2009-01-01

    The present study is a report on the presence of Mycobacterium avium in four birds of the psittaciform order kept as pets. Anatomopathological diagnosis showed lesions suggestive of the agent and presence of alcohol-acid resistant bacilli (AARB) shown by the Ziehl-Neelsen staining. The identification of Mycobacterium avium was performed by means of PRA (PCR Restriction Analysis). DNA was directly extracted from tissue of the lesions and blocked in paraffin. The role of this agent in pet bird infection is discussed, as well as its zoonotic potential. PMID:24031356

  5. A systematic review of lessons learned from PET molecular imaging research in atypical parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Niccolini, Flavia; Politis, Marios [Neurodegeneration Imaging Group, Institute of Psychiatry, Psychology and Neuroscience (IoPPN), King' s College London, London (United Kingdom)

    2016-11-15

    To systematically review the previous studies and current status of positron emission tomography (PET) molecular imaging research in atypical parkinsonism. MEDLINE, ISI Web of Science, Cochrane Library, and Scopus electronic databases were searched for articles published until 29th March 2016 and included brain PET studies in progressive supranuclear palsy (PSP), multiple system atrophy (MSA), and corticobasal syndrome (CBS). Only articles published in English and in peer-reviewed journals were included in this review. Case-reports, reviews, and non-human studies were excluded. Seventy-seven PET studies investigating the dopaminergic system, glucose metabolism, microglial activation, hyperphosphorilated tau, opioid receptors, the cholinergic system, and GABA{sub A} receptors in PSP, MSA, and CBS patients were included in this review. Disease-specific patterns of reduced glucose metabolism have shown higher accuracy than dopaminergic imaging techniques to distinguish between parkinsonian syndromes. Microglial activation has been found in all forms of atypical parkinsonism and reflects the known distribution of neuropathologic changes in these disorders. Opioid receptors are decreased in the striatum of PSP and MSA patients. Subcortical cholinergic dysfunction was more severe in MSA and PSP than Parkinson's disease patients although no significant changes in cortical cholinergic receptors were seen in PSP with cognitive impairment. GABA{sub A} receptors were decreased in metabolically affected cortical and subcortical regions in PSP patients. PET molecular imaging has provided valuable insight for understanding the mechanisms underlying atypical parkinsonism. Changes at a molecular level occur early in the course of these neurodegenerative diseases and PET imaging provides the means to aid differential diagnosis, monitor disease progression, identify of novel targets for pharmacotherapy, and monitor response to new treatments. (orig.)

  6. In-beam PET at clinical proton beams with pile-up rejection

    Energy Technology Data Exchange (ETDEWEB)

    Helmbrecht, Stephan; Fiedler, Fine; Iltzsche, Marc [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiation Physics; Enghardt, Wolfgang [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiation Physics; OncoRay - National Center for Radiation Research in Oncology, Dresden (Germany); Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiooncology; German Cancer Research Center (DKFZ), Heidelberg (Germany); German Cancer Consortium (DKTK), Dresden (Germany); Pausch, Guntram [OncoRay - National Center for Radiation Research in Oncology, Dresden (Germany); Tintori, Carlo [CAEN S.p.A., Viareggio (Italy); Kormoll, Thomas [OncoRay - National Center for Radiation Research in Oncology, Dresden (Germany); Technische Univ. Dresden (Germany). AG Radiation Physics

    2017-10-01

    Positron emission tomography (PET) is a means of imaging the β{sup +}-activity produced by the radiation field in ion beam therapy and therefore for treatment verification. Prompt γ-rays that are emitted during beam application challenge the detectors and electronics of PET systems, since those are designed for low and medium count rates. Typical PET detectors operated according to a modified Anger principle suffer from multiple events at high rates. Therefore, in-beam PET systems using such detectors rely on a synchronization of beam status and measurement to reject deteriorated data. In this work, a method for pile-up rejection is applied to conventional Anger logic block detectors. It allows for an in-beam data acquisition without further synchronization. Though cyclotrons produce a continuous wave beam, the radiation field shaping technique introduces breaks in the application. Time regimes mimicking synchrotrons as well as cyclotron based ones using double-scattering or pencil beam scanning field shaping at dose rates of 0.5, 1.0 and 2.0 Gy/min were investigated. Two types of inhomogeneous phantoms were imaged. The first one simulates cavity structures, the other one mimics a static lung irradiation. It could be shown that, depending on the dose rate and the beam time structure, in-beam measurement including a few seconds decay time only, yield images which revealed all inhomogeneities in the phantoms. This technique can be the basis for the development of an in-beam PET system with traditional detectors and off-the-shelf electronics.

  7. A systematic review of lessons learned from PET molecular imaging research in atypical parkinsonism

    International Nuclear Information System (INIS)

    Niccolini, Flavia; Politis, Marios

    2016-01-01

    To systematically review the previous studies and current status of positron emission tomography (PET) molecular imaging research in atypical parkinsonism. MEDLINE, ISI Web of Science, Cochrane Library, and Scopus electronic databases were searched for articles published until 29th March 2016 and included brain PET studies in progressive supranuclear palsy (PSP), multiple system atrophy (MSA), and corticobasal syndrome (CBS). Only articles published in English and in peer-reviewed journals were included in this review. Case-reports, reviews, and non-human studies were excluded. Seventy-seven PET studies investigating the dopaminergic system, glucose metabolism, microglial activation, hyperphosphorilated tau, opioid receptors, the cholinergic system, and GABA A receptors in PSP, MSA, and CBS patients were included in this review. Disease-specific patterns of reduced glucose metabolism have shown higher accuracy than dopaminergic imaging techniques to distinguish between parkinsonian syndromes. Microglial activation has been found in all forms of atypical parkinsonism and reflects the known distribution of neuropathologic changes in these disorders. Opioid receptors are decreased in the striatum of PSP and MSA patients. Subcortical cholinergic dysfunction was more severe in MSA and PSP than Parkinson's disease patients although no significant changes in cortical cholinergic receptors were seen in PSP with cognitive impairment. GABA A receptors were decreased in metabolically affected cortical and subcortical regions in PSP patients. PET molecular imaging has provided valuable insight for understanding the mechanisms underlying atypical parkinsonism. Changes at a molecular level occur early in the course of these neurodegenerative diseases and PET imaging provides the means to aid differential diagnosis, monitor disease progression, identify of novel targets for pharmacotherapy, and monitor response to new treatments. (orig.)

  8. Similarities between obesity in pets and children: the addiction model.

    Science.gov (United States)

    Pretlow, Robert A; Corbee, Ronald J

    2016-09-01

    Obesity in pets is a frustrating, major health problem. Obesity in human children is similar. Prevailing theories accounting for the rising obesity rates - for example, poor nutrition and sedentary activity - are being challenged. Obesity interventions in both pets and children have produced modest short-term but poor long-term results. New strategies are needed. A novel theory posits that obesity in pets and children is due to 'treats' and excessive meal amounts given by the 'pet-parent' and child-parent to obtain affection from the pet/child, which enables 'eating addiction' in the pet/child and results in parental 'co-dependence'. Pet-parents and child-parents may even become hostage to the treats/food to avoid the ire of the pet/child. Eating addiction in the pet/child also may be brought about by emotional factors such as stress, independent of parental co-dependence. An applicable treatment for child obesity has been trialled using classic addiction withdrawal/abstinence techniques, as well as behavioural addiction methods, with significant results. Both the child and the parent progress through withdrawal from specific 'problem foods', next from snacking (non-specific foods) and finally from excessive portions at meals (gradual reductions). This approach should adapt well for pets and pet-parents. Pet obesity is more 'pure' than child obesity, in that contributing factors and treatment points are essentially under the control of the pet-parent. Pet obesity might thus serve as an ideal test bed for the treatment and prevention of child obesity, with focus primarily on parental behaviours. Sharing information between the fields of pet and child obesity would be mutually beneficial.

  9. PET/MRI: A luxury or a necessity?

    Science.gov (United States)

    Carreras-Delgado, J L; Pérez-Dueñas, V; Riola-Parada, C; García-Cañamaque, L

    2016-01-01

    PET/MRI is a new multimodality technique with a promising future in diagnostic imaging. Technical limitations are being overcome. Interference between the two systems (PET and MRI) seems to have been resolved. MRI-based PET attenuation correction can be performed safely. Scan time is acceptable and the study is tolerable, with claustrophobia prevalence similar to that of MRI. Quantification with common parameters, such as Standardized Uptake Value (SUV), shows a fairly good correlation between both systems. However, PET/CT currently provides better results in scan time, scan costs, and patient comfort. Less patient radiation exposure is a big advantage of PET/MRI over PET/CT, which makes it particularly recommended in paediatric and adolescent patients requiring one or more studies. PET/MRI indications are the same as those of PET/CT, given that in cases where MRI is superior to CT, PET/MRI is superior to PET/CT. This superiority is clear in many soft tissue tumours. Moreover, it is common to perform both PET/CT and MRI in neurological diseases, as well as in some tumours, such as breast cancer. A single PET/MRI study replaces both with obvious benefit. MRI also allows other MRI-based PET corrections, such as motion or partial volume effect corrections. The better spatial resolution of MRI allows the transfer of well-defined MRI areas or small volumes of interest to PET image, in order to measure PET biomarkers in these areas. The richness of information of both techniques opens up immense possibilities of synergistic correlation between them. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  10. Breast cancer detection using high-resolution breast PET compared to whole-body PET or PET/CT.

    Science.gov (United States)

    Kalinyak, Judith E; Berg, Wendie A; Schilling, Kathy; Madsen, Kathleen S; Narayanan, Deepa; Tartar, Marie

    2014-02-01

    To compare the performance characteristics of positron emission mammography (PEM) with those of whole-body PET (WBPET) and PET/CT in women with newly diagnosed breast cancer. A total of 178 women consented to PEM for presurgical planning in an IRB-approved protocol and also underwent either WBPET (n = 69) or PET/CT (n = 109) imaging, as per usual care at three centers. Tumor detection sensitivity, positive predictive values, and (18)F-fluorodeoxyglucose (FDG) uptake were compared between the modalities. The effects of tumor size, type, and grade on detection were examined. The chi-squared or Fisher's exact tests were used to compare distributions between groups, and McNemar's test was used to compare distributions for paired data within subject groups, i.e. PEM versus WBPET or PEM versus PET/CT. The mean age of the women was 59 ± 12 years (median 60 years, range 26-89 years), with a mean invasive index tumor size of 1.6 ± 0.8 cm (median 1.5 cm, range 0.5-4.0 cm). PEM detected more index tumors (61/66, 92%) than WBPET (37/66, 56%; p PEM; p PEM (7/15, 47%) than with WBPET (1/15, 6.7%; p = 0.014) or PET/CT (3/23, 13% vs. 13/23, 57% for PEM; p = 0.003). Index tumor detection decreased with decreasing invasive tumor size for both WBPET (p = 0.002) and PET/CT (p PEM was not significantly affected (p = 0.20). FDG uptake, quantified in terms of maximum PEM uptake value, was lowest in ductal carcinoma in situ (median 1.5, range 0.7-3.0) and invasive lobular carcinoma (median 1.5, range 0.7-3.4), and highest in grade III invasive ductal carcinoma (median 3.1, range 1.4-12.9). PEM was more sensitive than either WBPET or PET/CT in showing index and additional ipsilateral breast tumors and remained highly sensitive for tumors smaller than 1 cm.

  11. PET and paediatrics; La tomographie par emission de positons (ou PET scan) en pediatrie

    Energy Technology Data Exchange (ETDEWEB)

    Boddaert, N. [Necker Enfants Malades, AP-HP, Serv Radiol Pediat, Paris (France); Ribeiro, M.J. [CEA, DSV, I2BM, Serv Hosp Frederic Joliot, F-91406 Orsay (France)

    2008-07-01

    Positon emission tomography (PET scan) is a functional imagery technique.As in scintigraphy, a radioactive tracer is administrated to the patient and its distribution into the organism is detected by a tomograph or a PET scanner. The nuclear medicine techniques which use radioactive tracers allow to obtain an imagery of the regional metabolism of glucose, blood flow or of different neurotransmitters. The PET-TDM (tomodensitometry) is an hybrid imagery system which associates a PET to a multi-bars scanner (4 to 64 bars). The use of hybrid imagery systems allows an anatomic register of the metabolic anomalies or others, as well as the adjustment of the attenuation of the emitted particles. (O.M.)

  12. Oral cancer diagnosed using PET/CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hee; Yang, Byoung Eun; Cho, Young Min [Hallym Univ. College of Medicine, Anyang (Korea, Republic of); Kim, Seong Gon [Sam Anyang General Hospital, Anyang (Korea, Republic of)

    2006-06-15

    PET/CT is a new imaging technology that combines high-quality Position Emission Tomography (PET) and Computed Tomography (CT). This imaging provides simultaneous anatomical and metabolic information. Therefore PET/CT is useful diagnostic modality for early detection og malignant tumor, accurate at aging, decision on therapeutic plan, monitoring response to therapy and rapid detection of recurrence. We report oral and maxillofacial cancers diagnosed by using PET/CT and the usefulness of PET/CT in the evaluation of postoperative recurrence.

  13. [¹⁸F]-fluorodeoxyglucose PET imaging of atherosclerosis

    DEFF Research Database (Denmark)

    Blomberg, Björn Alexander; Høilund-Carlsen, Poul Flemming

    2015-01-01

    [(18)F]-fluorodeoxyglucose PET ((18)FDG PET) imaging has emerged as a promising tool for assessment of atherosclerosis. By targeting atherosclerotic plaque glycolysis, a marker for plaque inflammation and hypoxia, (18)FDG PET can assess plaque vulnerability and potentially predict risk...... of atherosclerosis-related disease, such as stroke and myocardial infarction. With excellent reproducibility, (18)FDG PET can be a surrogate end point in clinical drug trials, improving trial efficiency. This article summarizes key findings in the literature, discusses limitations of (18)FDG PET imaging...

  14. Development of a full-ring ;add-on PET; prototype: A head coil with DOI-PET detectors for integrated PET/MRI

    Science.gov (United States)

    Nishikido, F.; Fujiwara, M.; Tashima, H.; Akram, M. S. H.; Suga, M.; Obata, T.; Yamaya, T.

    2017-08-01

    We developed a full-ring ;add-on PET; prototype which is brain-dedicated and consists of a RF-head coil with four-layer depth-of-interaction (DOI) PET detectors for integrated PET/MRI in order to evaluate performance of our previously proposed add-on PET system and to investigate the mutual influences between the individual PET and MRI modalities when they are integrated in simultaneous measurements. In this add-on PET prototype, the DOI detectors are mounted on the head coil and close to the patient head. As a result, higher sensitivity and higher spatial resolution can be achieved for the integrated PET/MRI, compared with conventional whole body PET/MRI systems. In addition, implementation cost can be reduced, tuning of the RF-coil can be optimized and PET and MRI images can be obtained simultaneously in exactly the same positions. Specifically, the full-ring prototype consists of eight DOI-PET detectors and a birdcage type head coil of a 3T MRI. The radius of the PET ring is 123.9 mm. The distance from the center to the RF-coil elements is 130.5 mm. The scintillator blocks consist of lutetium-yttrium oxyorthosilicate scintillators arranged in 19×6×4 layers with reflectors inserted between them. The size of each crystal element is 2.0 mm×2.0 mm ×5.0 mm. We evaluated performance of the full-ring prototype in simultaneous measurements of the integrated PET/MRI. We obtained spatial resolutions of 2.3 mm at the center of the field-of-view (FOV) and lower than 3.5 mm in the whole FOV. The energy resolution of 19.4% was obtained for 511 keV gamma-rays. In addition, we observed no degradation of PET performance caused by the MRI measurement. The signal-to-noise ratio (SNR) of the MRI image was 209.4 in simultaneous measurements with the PET. The maximum ΔB0 and maximum difference of the secondary magnetic field due to the eddy current effect were smaller than 0.8 ppm and ±5.0 μT, respectively. We concluded that sufficient spatial resolution and detector

  15. CyberPET: a PET service distributed over a wide area

    International Nuclear Information System (INIS)

    Pilloy, W.J.; Hellwig, D.; Schaeffer, A.; Hoffmann, P.; Lens, V.

    2002-01-01

    Aim: Demonstration of bi-directional PET data transmission, interactive display and co-registration, for the purpose of correlative imaging, treatment planning and teaching. Material and Method: In the year 2000, the initial problem to attend was to provide an effective PET service to a hospital (in Luxemburg) which lies 150 km away from a PET center (in another country). Once this solved, the procedure was expanded (in 2001) to co-registration with CT/MRI scans performed locally, and with radiotherapy simulation CT performed in another center 25 km away (in 2002). Equipment from various vendors was used (Siemens, Adac, GE, Hermes). With preliminary agreement of the national medical aid, patients are sent from the Nuclear Medicine Dept of the Centre Hospitalier in Luxemburg (CHL) to the Dept NM of the Saarland University Medical Center for PET examination. The digital data are then sent from the Siemens PET camera to a PC connected to the LAN, and then to a FTP server (Healthnet). The data are similarly collected by a PC of the hospital network in Luxemburg, and transferred to a Hermes NM station. The Dicom PET data are converted on the fly to Interfile, displayed interactively as any other tomographic data, printed and available on the NM image server. Since 2001, the PET data are co-registered with whole-body CT data recorded at CHL according to a specific protocol (see other paper of this group). Now in 2002, we are busy implementing the co-registration of PET data and simulation CT data obtained from the Centre Baclesse (CFB, 25 km from CHL) for the treatment planning of brain tumours (input into an ADAC system). Furthermore, we plan to send the data (after deletion of their digital ID) to a (South African) university which does not yet dispose of a PET camera, to allow the training of their registrars. Results: For the end-user clinician at CHL and CFB , the PET data have the quality of 'live data', which can be examined interactively, along with other imaging

  16. MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

    Science.gov (United States)

    Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian

    2018-03-08

    Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs

  17. Improving the Spatial Alignment in PET/CT Using Amplitude-Based Respiration-Gated PET and Respiration-Triggered CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Grootjans, W.; Osborne, D.R.; Meeuwis, A.P.; Hamill, J.J.; Acuff, S.; Geus-Oei, L.F. de; Visser, E.P.

    2015-01-01

    Respiratory motion during PET can cause inaccuracies in the quantification of radiotracer uptake, which negatively affects PET-guided radiotherapy planning. Quantitative accuracy can be improved by respiratory gating. However, additional miscalculation of standardized uptake value (SUV) in PET

  18. Automatic Channel Fault Detection on a Small Animal APD-Based Digital PET Scanner

    Science.gov (United States)

    Charest, Jonathan; Beaudoin, Jean-François; Cadorette, Jules; Lecomte, Roger; Brunet, Charles-Antoine; Fontaine, Réjean

    2014-10-01

    Avalanche photodiode (APD) based positron emission tomography (PET) scanners show enhanced imaging capabilities in terms of spatial resolution and contrast due to the one to one coupling and size of individual crystal-APD detectors. However, to ensure the maximal performance, these PET scanners require proper calibration by qualified scanner operators, which can become a cumbersome task because of the huge number of channels they are made of. An intelligent system (IS) intends to alleviate this workload by enabling a diagnosis of the observational errors of the scanner. The IS can be broken down into four hierarchical blocks: parameter extraction, channel fault detection, prioritization and diagnosis. One of the main activities of the IS consists in analyzing available channel data such as: normalization coincidence counts and single count rates, crystal identification classification data, energy histograms, APD bias and noise thresholds to establish the channel health status that will be used to detect channel faults. This paper focuses on the first two blocks of the IS: parameter extraction and channel fault detection. The purpose of the parameter extraction block is to process available data on individual channels into parameters that are subsequently used by the fault detection block to generate the channel health status. To ensure extensibility, the channel fault detection block is divided into indicators representing different aspects of PET scanner performance: sensitivity, timing, crystal identification and energy. Some experiments on a 8 cm axial length LabPET scanner located at the Sherbrooke Molecular Imaging Center demonstrated an erroneous channel fault detection rate of 10% (with a 95% confidence interval (CI) of [9, 11]) which is considered tolerable. Globally, the IS achieves a channel fault detection efficiency of 96% (CI: [95, 97]), which proves that many faults can be detected automatically. Increased fault detection efficiency would be

  19. Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI.

    Science.gov (United States)

    Lassen, Martin Lyngby; Rasul, Sazan; Beitzke, Dietrich; Stelzmüller, Marie-Elisabeth; Cal-Gonzalez, Jacobo; Hacker, Marcus; Beyer, Thomas

    2017-11-22

    To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ( 13 N-NH 3 : 813 ± 86 MBq) and metabolism ( 18 F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test-retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

  20. STATUS THERMAL COMFORT PADA LINGKUNGAN ATMOSFER PERMUKIMAN DI WILAYAH KECAMATAN DENPASAR BARAT

    Directory of Open Access Journals (Sweden)

    Komang Edy Indrawan Kusuma

    2016-07-01

    Full Text Available The effect of residential atmosphere environment generally gives environment stress to the life of the dwellers. One of the environment stress source is the unfulfilment of thermal comfort. The rapid development of residential at Denpasar City cause the variation on building density that are low, medium, high, and very high density classifications. Residential configuration of each classification gives very strong influence to status of urban’s thermal comfort. Purpose of the research is to understand the thermal index profile PET, to identify the status of thermal comfort and to analyze the influence of Tmrt to thermal index PET of residential atmosphere environment at West Denpasar Sub-district area. The research was performed at residential atmosphere environment of West Denpasar Sub-district area by using RayMan model simulation to obtain thermal index profile PET. Sampling technique used the stratified random sampling method with data diversity that is used based on the buildings density. The thermal index profile PET of residential of low density classification is the lowest thermal index profile PET compared to the other three classifications, which are the medium, high, and very high density. One hundred percent of status of thermal comfort of residential atmosphere environment is in hot thermal stress and based on average thermal index PET is on physiological stress level of “Strong heat stress”. Tmrt is the most influential variable to thermal index PET. The concept to increase the status of thermal comfort of residential atmosphere environment at West Denpasar area used the bioclimatic approach. Investigation of status of thermal comfort of residential atmosphere environment at West Denpasar Sub-district area has given the directive of urban planning in improving and revitalized urban spaces.

  1. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    -MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...... and measurement conditions. No differences were significant. The system was capable of 13C-MRSI of hyperpolarized 13C-pyruvate. Conclusions: Simultaneous PET and 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced......Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...

  2. Factors associated with furry pet ownership among patients with asthma.

    Science.gov (United States)

    Downes, Martin J; Roy, Angkana; McGinn, Thomas G; Wisnivesky, Juan P

    2010-09-01

    Exposure to indoor allergens is an established risk factor for poor asthma control. Current guidelines recommend removing pets from the home of patients with asthma. This cross-sectional study was conducted to determine the prevalence of furry pet ownership in asthmatics compared to non-asthmatics and to identify factors associated with furry pet ownership among those with asthma. Secondary analysis assessed characteristics among asthmatics that might be associated with allowing a furry pet into the bedroom. Using data from The National Asthma Survey collected from 2003 to 2004, we carried out univariate and multiple regression analyses, in 2009, to identify independent predictors of furry pet ownership in asthma sufferers after controlling for potential confounders. Overall, asthmatics were more likely to own a furry pet than nonasthmatic individuals in the general population (49.9% versus 44.8%, p pet ownership among asthmatics. Additionally, 68.7% of patients with asthma who own a furry pet allowed them into their bedroom. Higher income and carrying out pet into the bedroom. Furry pet ownership is equally or more common among asthmatics compared to those without asthma. The majority of asthmatics with furry pets allow them into the bedroom. Recognizing and addressing these problems may help decrease asthma morbidity.

  3. Clinical PET activities in European and Asia-Oceanian Countries

    International Nuclear Information System (INIS)

    Tashiro, Manabu; Ito, Masatoshi; Yamaguchi, Keiichiro; Kubota, Kazuo; Fujimoto, Toshihiko; Sasaki, Hidetada; Moser, E.

    2001-01-01

    Clinical diagnosis using positron emission tomography (PET) requires high costs. Therefore, sociomedical evaluation is very important for spread of clinical PET. In this report, sociomedical situation in European and Asia-Oceanian countries, especially concerning transportation of 18 F-FDG and reimbursement of medical costs for clinical PET indications, is reported. It seems that UK, Germany and Belgium are the most advanced in clinical PET in Europe. In these countries, many PET investigations are reimbursed though systems are different among the countries. In UK, both public and private insurance gives authorization for clinical PET to some extent. In Germany, private health insurance companies give authorization but public insurance has not. In Belgium, private health insurance does not exist and public insurance gives authorization for clinical PET. Other European countries seem to be in transitional stages. Transportation of 18 F-FDG has been already started in almost every country in Europe and Asia-Oceania. In Japan, neither transportation of FDG nor full reimbursement of clinical PET has not started yet and this situation seems to be exceptional. To promote clinical PET in Japan, there is the need of at least establishing a list of clinical indications for PET investigations and establishing commercial-based 18 F-FDG supplying system. They could be regarded as a kind of infrastructure for spread of clinical PET. (author)

  4. Status epilepticus

    NARCIS (Netherlands)

    Hensiek, AE; Absalom, Anthony

    2006-01-01

    Status epilepticus is defined as epileptic activity that continues for more than 30 minutes as a single seizure or as recurrent seizures without inter-ictal return of consciousness. The seizure activity is usually classified as partial or generalized. Although status epilepticus is an uncommon

  5. PET/MRI: Technical challenges and recent advances

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Ho; Choi, Yong; Im, Ki Chun [Molecular Imaging Research and Education Laboratory, Dept. of Electronic Engineering, Sogang University, Seoul (Korea, Republic of)

    2016-03-15

    Integrated positron emission tomography (PET)/magnetic resonance imaging (MRI), which can provide complementary functional and anatomical information about a specific organ or body system at the molecular level, has become a powerful imaging modality to understand the molecular biology details, disease mechanisms, and pharmacokinetics in animals and humans. Although the first experiment on the PET/MRI was performed in the early 1990s, its clinical application was accomplished in recent years because there were various technical challenges in integrating PET and MRI in a single system with minimum mutual interference between PET and MRI. This paper presents the technical challenges and recent advances in combining PET and MRI along with several approaches for improving PET image quality of the PET/MRI hybrid imaging system.

  6. Cost-effective analysis of PET application in NSCLC

    International Nuclear Information System (INIS)

    Gu Aichun; Liu Jianjun; Sun Xiaoguang; Shi Yiping; Huang Gang

    2006-01-01

    Objective: To evaluate the cost-effectiveness of PET and CT application for diagnosis of non-small cell lung cancer (NSCLC) in China. Methods: Using decision analysis method the diagnostic efficiency of PET and CT for diagnosis of NSCLC in china was analysed. And also the value of cost for accurate diagnosis (CAD), cost for accurate staging (CAS) and cost for effective therapy (CAT) was calculated. Results: (1) For the accurate diagnosis, CT was much more cost-effective than PET. (2) For the accurate staging, CT was still more cost-effective than PET. (3) For the all over diagnostic and therapeutic cost, PET was more cost-effective than CT. (4) The priority of PET to CT was for the diagnosis of stage I NSCLC. Conclusion: For the management of NSCLC patient in China, CT is more cost-effective for screening, whereas PET for clinical staging and monitoring therapeutic effect. (authors)

  7. Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study.

    Science.gov (United States)

    Eldib, Mootaz; Oesingmann, Niels; Faul, David D; Kostakoglu, Lale; Knešaurek, Karin; Fayad, Zahi A

    2016-08-01

    Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.

  8. Cardiovascular hybrid imaging using PET/MRI; Kardiovaskulaere Hybridbildgebung mit PET/MRT

    Energy Technology Data Exchange (ETDEWEB)

    Nensa, Felix; Schlosser, Thomas [Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie

    2014-12-15

    The following overview provides a summary of the state of the art and research as well as potential clinical applications of cardiovascular PET/MR imaging. PET/MRI systems have been clinically available for a few years, and their use in cardiac imaging has been successfully demonstrated. At this period in time, some of the technical difficulties that arose at the beginning have been solved; in particular with respect to MRI-based attenuation correction, caution should be exercised with PET quantification. In addition, many promising technical options are still in the developmental stage, such as MRI-based motion correction of PET data resulting from simultaneous MR acquisition, and are not yet available for cardiovascular imaging. On the other hand, PET/MRI has been used to demonstrate significant pathologies such as acute and chronic myocardial infarction, myocarditis or cardiac sarcoidosis; future applications in clinical routine or within studies appear to be possible. In coming years additional studies will have to be performed to prove diagnostic gain at a reasonable cost-benefit ratio before valid conclusions are possible regarding the clinical utility and future of cardiovascular PET/MR imaging.

  9. Bladder diverticulitis on PET/CT

    OpenAIRE

    Wosnitzer, Brian

    2015-01-01

    Diverticula are commonly seen in hollow viscous organs. One common complication of diverticula is infection, known as diverticulitis. Although diverticulitis has been extensively described with respect to the colon, not many cases describe diverticulitis of the urinary bladder. We report a case of diverticulitis of the bladder to emphasize the imaging findings on PET/CT and to discuss management and possible complications.

  10. Maillard reaction products in pet foods

    NARCIS (Netherlands)

    Rooijen, van C.

    2015-01-01

    Pet dogs and cats around the world are commonly fed processed commercial foods throughout their lives. Often heat treatments are used during the processing of these foods to improve nutrient digestibility, shelf life, and food safety. Processing is known to induce the Maillard reaction, in which a

  11. PET/MRI for Oncologic Brain Imaging

    DEFF Research Database (Denmark)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N

    2017-01-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology.Methods:Forty-nine PET/MRI brain scans were included: brain tumor studies using18F-fluoro-ethyl-tyrosine (18F-FET) (n= 31) and68Ga-DOTANOC (n= 7) and studies of healthy subjects using18...... by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs...... of the whole brain and 10 anatomic regions segmented on MR images.Results:For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUVmeanwere -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD...

  12. Methods Needed to Curb Rising Pet Population

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    Discusses socioeconomic problems of pet population explosion and recommends the conduct of educational programs and the implementation of surgical sterilization as a short-term answer to dog and cat control. Also considered are problems of using chemical contraceptives in human population control. (CC)

  13. Thin Time-Of-Flight PET project

    CERN Document Server

    The pre-R&D aims at designing and producing a compact and thin Time-Of-Flight PET detector device with depth of interaction measurement capability, which employs layered silicon sensors as active material, with a readout consisting of a new generation of very-low noise and very fast electronics based on SiGe Heterojunction Bipolar Transistors (HBT) components.

  14. PET imaging in patients with Modic changes

    DEFF Research Database (Denmark)

    Albert, Hanne; Pedersen, Henrik; Manniche, Claus

    2009-01-01

    The aim of this study was via PET imaging to reveal if any highly metabolic processes were occurring in Modic changes type 1 and/or in the adjacent discs. Modic changes (MC) are signal changes in the vertebral endplate and body visualised by magnetic resonance imaging (MRI). MC are strongly...... disc. All patients had a PET scan using FDG (18F-fluorodeoxyglucose) as tracer. RESULTS: Included in the study were 11 patients, 4 women and 7 men, mean age 48.1 year (range 20-65). All MC were situated in the vertebrae both above and below the previously herniated disc/discs. Ten patients had MC at 1...... level, and 1 had MC at 2 levels. The affected levels were 1 at L2/L3, 6 at L4 /L5, and 5 at L5/S1. All had a previous disc herniation and MC larger than 4 mm in diameter. Technically satisfactory PET scans were obtained. However, PET imaging showed no increases in metabolism in any vertebra or disc...

  15. A PET scanner developed by CERN

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This image shows a Position Emission Tomography (PET) scanner at the Hopital Cantonal Universitaire de Genève. Development of the multiwire proportional chamber at CERN in the mid-1970s was soon seen as a potential device for medical imaging. It is much more sensitive than previous devices and greatly reduced the dose of radiation received by the patient.

  16. OCCURENCE OF MERCURY IN PET FOOD

    Directory of Open Access Journals (Sweden)

    M.C. Abete

    2013-02-01

    Full Text Available Mercury levels in 61 complete pet feed containing fish were evaluated. In five samples a mercury content exceeding the maximum residues level (0.4 mg/kg was detected. The statistical evaluation didn’t show a significant correlation between the percentage of fish in feedingstuffs and the contamination level.

  17. PET/CT in Radiation Therapy Planning

    DEFF Research Database (Denmark)

    Specht, Lena; Berthelsen, Anne Kiil

    2018-01-01

    Radiation therapy (RT) is an important component of the management of lymphoma patients. Most lymphomas are metabolically active and accumulate 18F-fluorodeoxyglucose (FDG). Positron emission tomography with computer tomography (PET/CT) imaging using FDG is used routinely in staging and treatment...

  18. 24 CFR 960.707 - Pet ownership.

    Science.gov (United States)

    2010-04-01

    ... maintains each pet: (1) Responsibly; (2) In accordance with applicable State and local public health, animal control, and animal anti-cruelty laws and regulations; and (3) In accordance with the policies established... covered, or both; (2) Limitations on the number of animals in a unit, based on unit size; (3) Prohibitions...

  19. Probing neurodegeneration and aging: A PET approach

    Energy Technology Data Exchange (ETDEWEB)

    VanBrocklin, H.F. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    Positron Emission Tomography (PET) imaging has received wide application to the study of the aging brain and its diseases, most notably Parkinson`s Disease (PD) and Alzheimer`s Disease (AD). Basic neurological processes such as blood flow and glucose metabolism have been most often measured. Radioligands developed for specific neurochemical systems have amplified the flow and metabolism studies by more precisely defining the changes associated with degenerative processes. Our present research focuses on two additional applications of radiopharmaceutical development and PET imaging - (1) investigating the fundamental mechanisms of neurodegeneration and aging, and (2) assessing novel therapeutic intervention for PD with PET imaging. We have synthesized fluorine-18 labeled analogs of rotenone, a natural product that possesses high affinity to Complex I of the mitochondrial electron transport chain, and evaluated their potential to study changes in neuronal mitochondrial density and function. A large body evidence points to mitochondrial dysfunction as a key factor in aging and neurodegeneration. We are also currently evaluating the use of genetically transfected cells to treat PD. Primates are being imaged with [{sup 18}F]flouro-m-L-tyrosine before and after MPTP Parkinsonian type lesioning and following implantation of genetically altered cells capable of secreting tyrosine hydroxylase into the lesioned area. The ability to develop and apply PET probes has significantly enhanced the understanding of normal, aging, and degenerative processes of the brain.

  20. Dermatophytes in pet Guinea pigs and rabbits.

    Science.gov (United States)

    Kraemer, A; Mueller, R S; Werckenthin, C; Straubinger, R K; Hein, J

    2012-05-25

    The frequency of dermatophytes in pet Guinea pigs and rabbits. To determine the frequency and types of dermatophytes in pet Guinea pigs and rabbits. First, 2153 samples collected from pet Guinea pigs (n=1132) and rabbits (n=1021) with suspected dermatophytosis and submitted to three different laboratories for fungal culture were analysed. Subsequently, healthy Guinea pigs and rabbits, animals with skin lesions and with noncutaneous diseases were examined prospectively for dermatophytes. Trichophyton (T.) mentagrophytes was the most common fungal species isolated (91.6% and 72.3% of positive cultures from Guinea pigs (n=431) and rabbits (n=83), respectively). Animals with positive fungal culture did not show any gender predisposition, but affected animals were younger than those with negative fungal culture (PGuinea pigs and 0/140 healthy rabbits. In addition, fungal cultures of Guinea pigs with skin lesions (n=26) and other diseases (n=25) were positive in 7.7% and 8.0% respectively. Samples collected from 17 rabbits with skin lesions and 32 rabbits with noncutaneous disease were all negative in culture. T. mentagrophytes is the most common dermatophyte in pet Guinea pigs and rabbits, asymptomatic carriers are regularly seen in Guinea pigs, but not in rabbits. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  2. SPECT and PET in Eating Disorders

    NARCIS (Netherlands)

    van Waarde, Aren; Audenaert, Kurt; Busatto, Geraldo F.; Buchpiguel, Carlos; Dierckx, Rudi; Dierckx, Rudi AJO; Otte, Andreas; de Vries, Erik FJ; van Waarde, Aren; den Boer, Johan A

    2014-01-01

    Medical imaging techniques like PET and SPECT have been applied for investigation of brain function in anorexia and bulimia nervosa. Regional abnormalities have been detected in cerebral blood flow, glucose metabolism, the availability of several neurotransmitter receptors (serotonin 1A and 2A,

  3. PET imaging for brain tumor diagnostics.

    Science.gov (United States)

    Suchorska, Bogdana; Tonn, Joerg C; Jansen, Nathalie L

    2014-12-01

    Brain tumors differ in histology, biology, prognosis and treatment options. Although structural magnetic resonance is still the gold standard for morphological tumor characterization, molecular imaging has gained an increasing importance in assessment of tumor activity and malignancy. Amino acid PET is frequently used for surgery and biopsy planning as well as therapy monitoring in suspected primary brain tumors as well as metastatic lesions, whereas 18F-fluorodeoxyglucose (18F-FDG) remains the tracer of choice for evaluation of patients with primary central nervous system lymphoma. Application of somatostatin receptor ligands has improved tumor delineation in skull base meningioma and concurrently opened up new treatment possibilities in recurrent or surgically not assessable tumors.Recent development focuses on the implementation of hybrid PET/MRI as well as on the development of new tracers targeting tumor hypoxia, enzymes involved in neoplastic metabolic pathways and the combination of PET tracers with therapeutic agents. Implementation of molecular imaging in the clinical routine continues to improve management in patients with brain tumors. However, more prospective large sample studies are needed to validate the additional informative value of PET.

  4. People Can Catch Diseases from Their Pets

    Centers for Disease Control (CDC) Podcasts

    2013-01-23

    Dr. Carol Rubin, Associate Director for Zoonoses and One Health at CDC, discusses zoonotic diseases in pets.  Created: 1/23/2013 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 1/28/2013.

  5. Fundamentals of quantitative PET data analysis

    NARCIS (Netherlands)

    Willemsen, ATM; van den Hoff, J

    2002-01-01

    Drug analysis and development with PET should fully exhaust the ability of this tomographic technique to quantify regional tracer concentrations in vivo. Data evaluation based on visual inspection or assessment of regional image contrast is not sufficient for this purpose since much of the

  6. Physical and Chemical Aspects of PET Radiopharmaceuticals

    International Nuclear Information System (INIS)

    2004-09-01

    On the Workshop 23 contributions were presented. This proceedings includes 21 presentations delivered at the workshop. The topics discussed included: Cyclotron and Target Constructions; Target Chemistry; Radiopharmaceuticals Synthesis; Quality Control of Radiopharmaceuticals; GLP-GMP Design; PET Imaging. Each presentation has been indexed separately

  7. Captive Conditions of Pet Lemurs in Madagascar.

    Science.gov (United States)

    Reuter, Kim E; Schaefer, Melissa S

    2016-01-01

    Live extraction of wildlife is a threat to biodiversity and can compromise animal welfare standards. Studies of the captive environments and welfare of pet primates are known, but none has focused on Madagascar. We aimed to expand knowledge about the captive conditions of pet lemurs in Madagascar. We hypothesized that captive lemurs would often be kept in restrictive settings, including small cages, would be fed foods inconsistent with their natural diets and, as a result, would be in bad physical or psychological health. Data were collected via a web-based survey (n = 253 reports) and from the websites and social media pages of 25 hotels. Most lemurs seen by respondents were either kept on a rope/leash/chain or in a cage (67%), though some lemurs were habituated and were not restrained (28%). Most of the time (72%) cages were considered small, and lemurs were rarely kept in captivity together with other lemurs (81% of lemurs were caged alone). Pet lemurs were often fed foods inconsistent with their natural diets, and most (53%) were described as being in bad health. These findings point to a need to undertake outreach to pet lemur owners in Madagascar about the captivity requirements of primates. © 2016 S. Karger AG, Basel.

  8. Maillard reaction products in pet foods

    NARCIS (Netherlands)

    Rooijen, van C.

    2015-01-01

    Pet dogs and cats around the world are commonly fed processed commercial foods throughout their lives. Often heat treatments are used during the processing of these foods to improve nutrient digestibility, shelf life, and food safety. Processing is known to induce the Maillard reaction, in which

  9. The utility of 18F-FDG PET/CT for diagnosis and adjustment of therapy in patients with active chronic sarcoidosis.

    Science.gov (United States)

    Sobic-Saranovic, Dragana; Grozdic, Isidora; Videnovic-Ivanov, Jelica; Vucinic-Mihailovic, Violeta; Artiko, Vera; Saranovic, Djordjije; Djuric-Stefanovic, Aleksandra; Masulovic, Dragan; Odalovic, Strahinja; Ilic-Dudvarski, Aleksandra; Popevic, Spasoje; Pavlovic, Smiljana; Obradovic, Vladimir

    2012-10-01

    The purpose of this study was to assess the utility of (18)F-FDG PET/CT for detection of inflammation in granulomatous sites and management of patients with chronic sarcoidosis. The 3 specific aims were to assess differences between (18)F-FDG PET/CT and multidetector CT (MDCT) findings, to compare (18)F-FDG PET/CT results with serum levels of angiotensin-converting enzyme (ACE), and to determine whether (18)F-FDG PET/CT findings are associated with the decision to change therapy. We studied 90 sarcoidosis patients (mean age ± SD, 47 ± 12 y; 32 men and 58 women) with persistent symptoms who were referred for (18)F-FDG PET/CT evaluation to assess the extent of inflammation. They also underwent MDCT and measurement of serum ACE level. After the follow-up (12 ± 5 mo after (18)F-FDG PET/CT), the clinical status and changes in therapy were analyzed. (18)F-FDG PET/CT detected inflammation in 74 patients (82%) (maximum standardized uptake value, 8.1 ± 3.9). MDCT was positive for sarcoidosis in 6 additional patients (80, 89%). The difference between the 2 methods was not significant (P = 0.238, McNemar test), and their agreement was fair (κ = 0.198). Although ACE levels were significantly higher in patients with positive than negative (18)F-FDG PET/CT results (P = 0.002, Mann-Whitney test), 38 patients (51%) with positive (18)F-FDG PET/CT results had normal ACE levels. The therapy was initiated or changed in 73 out of 90 patients (81%). Both univariate and multivariate logistic regression analyses indicated that positive (18)F-FDG PET/CT results were significantly (P changes in therapy, with no contribution from age, sex, ACE level, CT results, or previous therapy. Our results indicate that (18)F-FDG PET/CT is a useful adjunct to other diagnostic methods for detecting active inflammatory sites in chronic sarcoidosis patients with persistent symptoms, especially those with normal ACE levels. (18)F-FDG PET/CT proved advantageous for determining the spread of active

  10. Role of PET in gene therapy

    International Nuclear Information System (INIS)

    Lee, Kyung Han

    2002-01-01

    In addition to the well-established use of positron emission tomography (PET) in clinical oncology, novel roles for PET are rapidly emerging in the field of gene therapy. Methods for controlled gene delivery to living bodies, made available through advances in molecular biology, are currently being employed in animals for reasearch purposes and in humans to treat diseases such as cancer. Although gene therapy is still in its early developmental stage, it is perceived that many serious illnesses could be treated successfully by the use of therapeutic gene delivery. A major challenge for the widespread use of human gene therapy is to achieve a controlled and effective delivery of foreign genes to target cells and subsequently, adequate levels of expression. As such, the availability of noninvasive imaging methods to accurately assess the location, duration, and level of transgene expression is critical for optimizing gene therapy strategies. Current endeavors to achieve this goal include methods that utilize magnetic resonance imaging, optical imaging, and nuclear imaging techniques. As for PET, reporter systems that utilize gene encoding enzymes that accumulate postion labeled substrates and those transcribing surface receptors that bind specific positron labeled ligands have been successfully developed. More recent advances in this area include improved reporter gene constructs and radiotracers, introduction of potential strategies to monitor endogenous gene expression, and human pilot studies evaluating the distribution and safety of reporter PET tracers. The remarkably rapid progress occuring in gene imaging technology indicates its importance and wide range of application. As such, gene imaging is likely to become a major and exciting new area for future application of PET technology

  11. Chlamydia psittaci exposure in pet birds.

    Science.gov (United States)

    Cong, W; Huang, S Y; Zhang, X X; Zhou, D H; Xu, M J; Zhao, Q; Qian, A D; Zhu, X Q

    2014-04-01

    Chlamydia psittaci is a zoonotic pathogen with a wide range of avian hosts and may be transmitted to humans and cause severe disease. To assess the risk of psittacosis posed by pet birds, the seroprevalence of Chlamydia psittaci antibodies in 360 Eurasian siskins (Carduelis spinus), 289 oriental skylarks (Alauda arvensis) and 36 black-tailed grosbeaks (Coccothraustes migratorius) in Gansu province, north-western China was detected by an indirect haemagglutination assay. Twenty-seven out of 289 (9.34 %) Alauda arvensis, 45 out of 360 (12.50 %) Carduelis spinus and 2 out of 36 (5.56 %) Coccothraustes migratorius were positive for Chlamydia psittaci infection at a cut-off dilution of 1 : 16. The prevalence of Chlamydia psittaci was higher in Carduelis spinus (12.5 %) than in Alauda arvensis (9.34 %) and Coccothraustes migratorius (5.56 %); however, the differences were not statistically significant (P>0.05). Statistical analysis indicated that Chlamydia psittaci seroprevalence in adult pet birds (12.4 %, 67/540) was significantly higher than that in juvenile pet birds (4.83 %, 7/145) (P<0.01). There was no statistical difference in Chlamydia psittaci seroprevalence between male (12.4 %) and female (8.27 %) birds. To our knowledge, this is the first report indicating the seroprevalence of Chlamydia psittaci exposure in pet birds in China. Our results indicate that close contact with pet birds poses the risk of zoonotic transmission of Chlamydia psittaci.

  12. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  13. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  14. PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner

    International Nuclear Information System (INIS)

    Hirsch, Franz Wolfgang; Sorge, Ina; Viehweger, Adrian; Ritter, Lutz; Sattler, Bernhard; Kurch, Lars; Werner, Peter; Jochimsen, Thies; Barthel, Henryk; Sabri, Osama; Kluge, Regine; Bierbach, Uta; Till, Holger

    2013-01-01

    Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition of PET and MR data combines the advantages of the two previously separate modalities. Furthermore, the technique also enables whole-body diffusion-weighted imaging (DWI) and statements to be made about the biological cellularity and nuclear/cytoplasmic ratio of tumours. Combined PET/MR saves time and resources. One disadvantage of PET/MR is that in order to have an effect, a significantly longer examination time is needed than with PET/CT. In our initial experience, PET/MR has turned out to be an unexpectedly stable and reliable hybrid imaging modality, which generates a complementary diagnostic study of great additional value. (orig.)

  15. PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, Franz Wolfgang; Sorge, Ina; Viehweger, Adrian; Ritter, Lutz [University of Leipzig, Department of Paediatric Radiology, Leipzig (Germany); Sattler, Bernhard; Kurch, Lars; Werner, Peter; Jochimsen, Thies; Barthel, Henryk; Sabri, Osama; Kluge, Regine [University of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Bierbach, Uta [University of Leipzig, Department of Paediatric Oncology, Leipzig (Germany); Till, Holger [University of Leipzig, Department of Paediatric Surgery, Leipzig (Germany)

    2013-07-15

    Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition of PET and MR data combines the advantages of the two previously separate modalities. Furthermore, the technique also enables whole-body diffusion-weighted imaging (DWI) and statements to be made about the biological cellularity and nuclear/cytoplasmic ratio of tumours. Combined PET/MR saves time and resources. One disadvantage of PET/MR is that in order to have an effect, a significantly longer examination time is needed than with PET/CT. In our initial experience, PET/MR has turned out to be an unexpectedly stable and reliable hybrid imaging modality, which generates a complementary diagnostic study of great additional value. (orig.)

  16. PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner.

    Science.gov (United States)

    Hirsch, Franz Wolfgang; Sattler, Bernhard; Sorge, Ina; Kurch, Lars; Viehweger, Adrian; Ritter, Lutz; Werner, Peter; Jochimsen, Thies; Barthel, Henryk; Bierbach, Uta; Till, Holger; Sabri, Osama; Kluge, Regine

    2013-07-01

    Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition of PET and MR data combines the advantages of the two previously separate modalities. Furthermore, the technique also enables whole-body diffusion-weighted imaging (DWI) and statements to be made about the biological cellularity and nuclear/cytoplasmic ratio of tumours. Combined PET/MR saves time and resources. One disadvantage of PET/MR is that in order to have an effect, a significantly longer examination time is needed than with PET/CT. In our initial experience, PET/MR has turned out to be an unexpectedly stable and reliable hybrid imaging modality, which generates a complementary diagnostic study of great additional value.

  17. Pet ownership and older women: the relationships among loneliness, pet attachment support, human social support, and depressed mood.

    Science.gov (United States)

    Krause-Parello, Cheryl A

    2012-01-01

    Pets can play a positive role in the both the physical and psychological health of older adults. This cross sectional study investigated the relationships among loneliness, pet attachment support, human social support, and depressed mood in a convenience sample of 159 pet-owning older women residing in the community. Participants completed loneliness, pet attachment support, human social support, and depressed mood scales. The results supported significant relationships between loneliness, pet attachment support, human social support, and depressed mood. No relationship was found between human social support and depressed mood. Pet attachment support, but not human social support, influenced the relationship between loneliness and depressed mood indicating the importance of pet attachment as a greater form of support in this sample. Clinical and social implications for nurses working with the geriatric population were identified and discussed. Copyright © 2012 Mosby, Inc. All rights reserved.

  18. FDG PET/CT patterns of treatment failure of malignant pleural mesothelioma: relationship to histologic type, treatment algorithm, and survival

    Energy Technology Data Exchange (ETDEWEB)

    Gerbaudo, Victor H.; Mamede, Marcelo [Brigham and Women' s Hospital, Harvard Medical School, Division of Nuclear Medicine and Molecular Imaging, Boston, MA (United States); Trotman-Dickenson, Beatrice; Hatabu, Hiroto [Brigham and Women' s Hospital, Harvard Medical School, Division of Thoracic Radiology, Boston, MA (United States); Sugarbaker, David J. [Brigham and Women' s Hospital, Harvard Medical School, Division of Thoracic Surgery, Boston, MA (United States)

    2011-05-15

    unplanned treatment at the time of failure. Multivariate analysis showed that histologic type remained the only independent predictor of progression-free survival. Survival after relapse was independently predicted by the pattern of FDG uptake and PET nodal status, and overall survival by the maximum standard uptake value. FDG PET/CT is an accurate modality to diagnose and to estimate the extent of locoregional and distant MPM recurrence, and it carries independent prognostic value. Once the disease recurs, survival outcomes seem to be independent of histologic type and highly dependent on the intensity of lesion uptake and on the pattern of metabolically active disease in FDG PET/CT. Our observations should be considered limited to patients treated surgically with or without perioperative therapies and should not be extrapolated to those unresectable cases treated with chemotherapy alone. (orig.)

  19. Comparison of the diagnosis using FDG-PET and AC-PET with histopathological features in lung adenocarcinomas

    International Nuclear Information System (INIS)

    Koizumi, Satoko

    2011-01-01

    Fluorodeoxyglucose-positron emission tomography (FDG-PET) is a useful tool for lung cancer diagnosis because of its good sensitivity and specificity. However, FDG-PET is problematically causing the false negative in cases of well differentiated lung adenocarcinomas which are low grade malignancies. Acetate (AC)-PET using 11 C-acetate is thought to be a superior detection tool for low grade malignancies. In this study, comparison of each type of PET in relation with histopathological features of lung adenocarcinomas was conducted. Samples obtained from 81 lesions in 75 patients with a lung adenocarcinoma who were operated at various institutions of our collaborators between 2005 and 2009 following FDG-PET and AC-PET procedures were examined. These samples consisted of fifty-seven cases of a well differentiated adenocarcinoma and twenty-four cases of a moderately- or a poorly-differentiated adenocarcinoma. Relationships between the histopathological factors (ly, v, p) as well as the lymphatic microvessel and microvessel densities in a tumor and FDG- and AC-PET findings were evaluated. AC-PET was more sensitive than FDG-PET (0.58 vs 0.74, p=0.0001). FDG-PET showed a correlation with invasiveness of the tumor and intratumoral lymphatic microvessel density (p<0.05). Furthermore, AC-PET possessed a superior sensitivity for the detection of well differentiated adenocarcinomas, and tumors without ly, v, or p factors. In lung adenocarcinoma AC-PET showed better sensitivity than FDG-PET and true positive in all cases of stage I B or more. FDG-PET showed the correlation with the pathological invasiveness (ly, v, p) of a tumor and the intratumoral lymphatic microvessel density. (author)

  20. PKU-PET-II: A novel SiPM-based PET imaging system for small animals

    Science.gov (United States)

    Xie, Zhaoheng; Li, Suying; Zhou, Kun; Vuletic, Ivan; Meng, Xiangxi; Zhu, Sihao; Xu, Huan; Yang, Kun; Xu, Baixuan; Zhang, Jinming; Ren, Qiushi

    2018-01-01

    The objective of this study was to introduce, describe, and validate the performance of a novel preclinical silicon photomultiplier (SiPM)-based PET system (PKU-PET-II). Briefly, the detector assembly consisted of cerium-doped lutetium-yttrium oxyorthosilicate (LYSO) crystals, with dimensions of 2 ×2 ×15 mm3, that offered a 60 mm transaxial field of view (FOV) and 32 mm axial FOV, respectively. The compact front-end electronics readout and digital controller implemented architecture in the FPGA were noteworthy improvements in PKU-PET-II over its predecessor (PKU-PET-I). Based on the National Electrical Manufacturers Association (NEMA) NU 04-2008 standards, the design of the PKU-PET-II system was validated by a phantom experiment. The results presented spatial resolution (evaluated as full width at half maximum) with a system range from 1.68 ±0.07 to 2.31 ±0.03 mm at the FOV center and from 1.43 ±0.02 to 2.10 ±0.10 mm at the 1/4th axial FOV, respectively. The system's absolute sensitivity at the center position was 1.35% with the coincidence window of 6 ns and energy window of 300-700 keV. In addition, the NEMA image quality phantom and an animal study results validated the system imaging performance in preclinical imaging application. In conclusion, this SiPM-based, small-animal PET system (PKU-PET-II) provided higher-resolution, adequate sensitivity, and excellent image quality and has potential as a useful tool for real-time imaging of disease progression and development in vivo.