WorldWideScience

Sample records for pressure-sensitive paint measurements

  1. Water-Based Pressure-Sensitive Paints

    Science.gov (United States)

    Jordan, Jeffrey D.; Watkins, A. Neal; Oglesby, Donald M.; Ingram, JoAnne L.

    2006-01-01

    Water-based pressure-sensitive paints (PSPs) have been invented as alternatives to conventional organic-solvent-based pressure-sensitive paints, which are used primarily for indicating distributions of air pressure on wind-tunnel models. Typically, PSPs are sprayed onto aerodynamic models after they have been mounted in wind tunnels. When conventional organic-solvent-based PSPs are used, this practice creates a problem of removing toxic fumes from inside the wind tunnels. The use of water-based PSPs eliminates this problem. The waterbased PSPs offer high performance as pressure indicators, plus all the advantages of common water-based paints (low toxicity, low concentrations of volatile organic compounds, and easy cleanup by use of water).

  2. Oxygen-Independent Pressure Sensitive Paint, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Pressure sensitive paint (PSP) systems are excellent tools for performing global pressure measurements in aerodynamic testing, especially in wind tunnel studies. The...

  3. Application of pressure-sensitive paint in shock-boundary layer interaction experiments

    OpenAIRE

    Seivwright, Douglas L.

    1996-01-01

    Approved for public release; distribution is unlimited A new type of pressure transducer, pressure-sensitive paint, was used to obtain pressure distributions associated with shock-boundary layer interaction. Based on the principle of photoluminescence and the process of oxygen quenching, pressure-sensitive paint provides a continous mapping of a pressure field over a surface of interest. The data measurement and acquisition system developed for use with the photoluminescence sensor was eva...

  4. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    Science.gov (United States)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  5. Water-Based Pressure Sensitive Paint

    Science.gov (United States)

    Oglesby, Donald M.; Ingram, JoAnne L.; Jordan, Jeffrey D.; Watkins, A. Neal; Leighty, Bradley D.

    2004-01-01

    Preparation and performance of a water-based pressure sensitive paint (PSP) is described. A water emulsion of an oxygen permeable polymer and a platinum porphyrin type luminescent compound were dispersed in a water matrix to produce a PSP that performs well without the use of volatile, toxic solvents. The primary advantages of this PSP are reduced contamination of wind tunnels in which it is used, lower health risk to its users, and easier cleanup and disposal. This also represents a cost reduction by eliminating the need for elaborate ventilation and user protection during application. The water-based PSP described has all the characteristics associated with water-based paints (low toxicity, very low volatile organic chemicals, and easy water cleanup) but also has high performance as a global pressure sensor for PSP measurements in wind tunnels. The use of a water-based PSP virtually eliminates the toxic fumes associated with the application of PSPs to a model in wind tunnels.

  6. Binary pressure-sensitive paint measurements using miniaturised, colour, machine vision cameras

    Science.gov (United States)

    Quinn, Mark Kenneth

    2018-05-01

    Recent advances in machine vision technology and capability have led to machine vision cameras becoming applicable for scientific imaging. This study aims to demonstrate the applicability of machine vision colour cameras for the measurement of dual-component pressure-sensitive paint (PSP). The presence of a second luminophore component in the PSP mixture significantly reduces its inherent temperature sensitivity, increasing its applicability at low speeds. All of the devices tested are smaller than the cooled CCD cameras traditionally used and most are of significantly lower cost, thereby increasing the accessibility of such technology and techniques. Comparisons between three machine vision cameras, a three CCD camera, and a commercially available specialist PSP camera are made on a range of parameters, and a detailed PSP calibration is conducted in a static calibration chamber. The findings demonstrate that colour machine vision cameras can be used for quantitative, dual-component, pressure measurements. These results give rise to the possibility of performing on-board dual-component PSP measurements in wind tunnels or on real flight/road vehicles.

  7. Pressure-Sensitive Paints Advance Rotorcraft Design Testing

    Science.gov (United States)

    2013-01-01

    The rotors of certain helicopters can spin at speeds as high as 500 revolutions per minute. As the blades slice through the air, they flex, moving into the wind and back out, experiencing pressure changes on the order of thousands of times a second and even higher. All of this makes acquiring a true understanding of rotorcraft aerodynamics a difficult task. A traditional means of acquiring aerodynamic data is to conduct wind tunnel tests using a vehicle model outfitted with pressure taps and other sensors. These sensors add significant costs to wind tunnel testing while only providing measurements at discrete locations on the model's surface. In addition, standard sensor solutions do not work for pulling data from a rotor in motion. "Typical static pressure instrumentation can't handle that," explains Neal Watkins, electronics engineer in Langley Research Center s Advanced Sensing and Optical Measurement Branch. "There are dynamic pressure taps, but your costs go up by a factor of five to ten if you use those. In addition, recovery of the pressure tap readings is accomplished through slip rings, which allow only a limited amount of sensors and can require significant maintenance throughout a typical rotor test." One alternative to sensor-based wind tunnel testing is pressure sensitive paint (PSP). A coating of a specialized paint containing luminescent material is applied to the model. When exposed to an LED or laser light source, the material glows. The glowing material tends to be reactive to oxygen, explains Watkins, which causes the glow to diminish. The more oxygen that is present (or the more air present, since oxygen exists in a fixed proportion in air), the less the painted surface glows. Imaged with a camera, the areas experiencing greater air pressure show up darker than areas of less pressure. "The paint allows for a global pressure map as opposed to specific points," says Watkins. With PSP, each pixel recorded by the camera becomes an optical pressure

  8. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras.

    Science.gov (United States)

    Quinn, Mark Kenneth; Spinosa, Emanuele; Roberts, David A

    2017-07-25

    Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.

  9. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras

    Directory of Open Access Journals (Sweden)

    Mark Kenneth Quinn

    2017-07-01

    Full Text Available Measurements of pressure-sensitive paint (PSP have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.

  10. Pressure-Sensitive Paint Measurements on the NASA Common Research Model in the NASA 11-ft Transonic Wind Tunnel

    Science.gov (United States)

    Bell, James H.

    2011-01-01

    The luminescence lifetime technique was used to make pressure-sensitive paint (PSP) measurements on a 2.7% Common Research Model in the NASA Ames 11ft Transonic Wind Tunnel. PSP data were obtained on the upper and lower surfaces of the wing and horizontal tail, as well as one side of the fuselage. Data were taken for several model attitudes of interest at Mach numbers between 0.70 and 0.87. Image data were mapped onto a three-dimensional surface grid suitable both for comparison with CFD and for integration of pressures to determine loads. Luminescence lifetime measurements were made using strobed LED (light-emitting diode) lamps to illuminate the PSP and fast-framing interline transfer cameras to acquire the PSP emission.

  11. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  12. Detection of small-amplitude periodic surface pressure fluctuation by pressure-sensitive paint measurements using frequency-domain methods

    Science.gov (United States)

    Noda, Takahiro; Nakakita, Kazuyki; Wakahara, Masaki; Kameda, Masaharu

    2018-06-01

    Image measurement using pressure-sensitive paint (PSP) is an effective tool for analyzing the unsteady pressure field on the surface of a body in a low-speed air flow, which is associated with wind noise. In this study, the surface pressure fluctuation due to the tonal trailing edge (TE) noise for a two-dimensional NACA 0012 airfoil was quantitatively detected using a porous anodized aluminum PSP (AA-PSP). The emission from the PSP upon illumination by a blue laser diode was captured using a 12-bit high-speed complementary metal-oxide-semiconductor (CMOS) camera. The intensities of the captured images were converted to pressures using a standard intensity-based method. Three image-processing methods based on the fast Fourier transform (FFT) were tested to determine their efficiency in improving the signal-to-noise ratio (SNR) of the unsteady PSP data. In addition to two fundamental FFT techniques (the full data and ensemble averaging FFTs), a technique using the coherent output power (COP), which involves the cross correlation between the PSP data and the signal measured using a pointwise sound-level meter, was tested. Preliminary tests indicated that random photon shot noise dominates the intensity fluctuations in the captured PSP emissions above 200 Hz. Pressure fluctuations associated with the TE noise, whose dominant frequency is approximately 940 Hz, were successfully measured by analyzing 40,960 sequential PSP images recorded at 10 kfps. Quantitative validation using the power spectrum indicates that the COP technique is the most effective method of identification of the pressure fluctuation directly related to TE noise. It is possible to distinguish power differences with a resolution of 10 Pa^2 (4 Pa in amplitude) when the COP was employed without use of another wind-off data. This resolution cannot be achieved by the ensemble averaging FFT because of an insufficient elimination of the background noise.

  13. On the Unsteadiness of a Transitional Shock Wave-Boundary Layer Interaction Using Fast-Response Pressure-Sensitive Paint

    Science.gov (United States)

    Lash, E. Lara; Schmisseur, John

    2017-11-01

    Pressure-sensitive paint has been used to evaluate the unsteady dynamics of transitional and turbulent shock wave-boundary layer interactions generated by a vertical cylinder on a flat plate in a Mach 2 freestream. The resulting shock structure consists of an inviscid bow shock that bifurcates into a separation shock and trailing shock. The primary features of interest are the separation shock and an upstream influence shock that is intermittently present in transitional boundary layer interactions, but not observed in turbulent interactions. The power spectral densities, frequency peaks, and normalized wall pressures are analyzed as the incoming boundary layer state changes from transitional to fully turbulent, comparing both centerline and outboard regions of the interaction. The present study compares the scales and frequencies of the dynamics of the separation shock structure in different boundary layer regimes. Synchronized high-speed Schlieren imaging provides quantitative statistical analyses as well as qualitative comparisons to the fast-response pressure sensitive paint measurements. Materials based on research supported by the U.S. Office of Naval Research under Award Number N00014-15-1-2269.

  14. Flow Visualization at Cryogenic Conditions Using a Modified Pressure Sensitive Paint Approach

    Science.gov (United States)

    Watkins, A. Neal; Goad, William K.; Obara, Clifford J.; Sprinkle, Danny R.; Campbell, Richard L.; Carter, Melissa B.; Pendergraft, Odis C., Jr.; Bell, James H.; Ingram, JoAnne L.; Oglesby, Donald M.

    2005-01-01

    A modification to the Pressure Sensitive Paint (PSP) method was used to visualize streamlines on a Blended Wing Body (BWB) model at full-scale flight Reynolds numbers. In order to achieve these conditions, the tests were carried out in the National Transonic Facility operating under cryogenic conditions in a nitrogen environment. Oxygen is required for conventional PSP measurements, and several tests have been successfully completed in nitrogen environments by injecting small amounts (typically < 3000 ppm) of oxygen into the flow. A similar technique was employed here, except that air was purged through pressure tap orifices already existent on the model surface, resulting in changes in the PSP wherever oxygen was present. The results agree quite well with predicted results obtained through computational fluid dynamics analysis (CFD), which show this to be a viable technique for visualizing flows without resorting to more invasive procedures such as oil flow or minitufts.

  15. Pressure-sensitive paint on a truncated cone in hypersonic flow at incidences

    International Nuclear Information System (INIS)

    Yang, L.; Erdem, E.; Zare-Behtash, H.; Kontis, K.; Saravanan, S.

    2012-01-01

    Highlights: ► Global pressure map over the truncated cone is obtained at various incidence angles in Mach 5 flow. ► Successful application of AA-PSP in hypersonic flow expands operation area of this technique. ► AA-PSP reveals complex three-dimensional pattern which is difficult for transducer to obtain. ► Quantitative data provides strong correlation with colour Schlieren and oil flow results. ► High spatial resolution pressure mappings identify small scale vortices and flow separation. - Abstract: The flow over a truncated cone is a classical and fundamental problem for aerodynamic research due to its three-dimensional and complicated characteristics. The flow is made more complex when examining high angles of incidence. Recently these types of flows have drawn more attention for the purposes of drag reduction in supersonic/hypersonic flows. In the present study the flow over a truncated cone at various incidences was experimentally investigated in a Mach 5 flow with a unit Reynolds number of 13.5 × 10 6 m −1 . The cone semi-apex angle is 15° and the truncation ratio (truncated length/cone length) is 0.5. The incidence of the model varied from −12° to 12° with 3° intervals relative to the freestream direction. The external flow around the truncated cone was visualised by colour Schlieren photography, while the surface flow pattern was revealed using the oil flow method. The surface pressure distribution was measured using the anodized aluminium pressure-sensitive paint (AA-PSP) technique. Both top and sideviews of the pressure distribution on the model surface were acquired at various incidences. AA-PSP showed high pressure sensitivity and captured the complicated flow structures which correlated well with the colour Schlieren and oil flow visualisation results.

  16. Measurements of Pressure of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Papers

    Science.gov (United States)

    Inose, Naoto; Ide, Masao

    1993-05-01

    This paper describes measurements of pressures at the focal region of the extracorporeal shock wave lithotripter (ESWL) using pressure-sensitive papers. At the focal region of ESWL, ordinary hydrophones are quickly damaged, because of very high pressures. Recently, measurements of pressure at the focal region of ESWL using pressure-sensitive paper have been advised. Therefore, we have studied the effectiveness of pressure-sensitive papers in the measurement of high acoustic pressures at the focal region of ESWL.

  17. Pressure Sensitive Paint Applied to Flexible Models

    Data.gov (United States)

    National Aeronautics and Space Administration — One gap in current pressure-measurement technology is a high-spatial-resolution method for accurately measuring pressures on spatially and temporally varying...

  18. Investigation of Unsteady Pressure-Sensitive Paint (uPSP) and a Dynamic Loads Balance to Predict Launch Vehicle Buffet Environments

    Science.gov (United States)

    Schuster, David M.; Panda, Jayanta; Ross, James C.; Roozeboom, Nettie H.; Burnside, Nathan J.; Ngo, Christina L.; Kumagai, Hiro; Sellers, Marvin; Powell, Jessica M.; Sekula, Martin K.; hide

    2016-01-01

    This NESC assessment examined the accuracy of estimating buffet loads on in-line launch vehicles without booster attachments using sparse unsteady pressure measurements. The buffet loads computed using sparse sensor data were compared with estimates derived using measurements with much higher spatial resolution. The current method for estimating launch vehicle buffet loads is through wind tunnel testing of models with approximately 400 unsteady pressure transducers. Even with this relatively large number of sensors, the coverage can be insufficient to provide reliable integrated unsteady loads on vehicles. In general, sparse sensor spacing requires the use of coherence-length-based corrections in the azimuthal and axial directions to integrate the unsteady pressures and obtain reasonable estimates of the buffet loads. Coherence corrections have been used to estimate buffet loads for a variety of launch vehicles with the assumption methodology results in reasonably conservative loads. For the Space Launch System (SLS), the first estimates of buffet loads exceeded the limits of the vehicle structure, so additional tests with higher sensor density were conducted to better define the buffet loads and possibly avoid expensive modifications to the vehicle design. Without the additional tests and improvements to the coherence-length analysis methods, there would have been significant impacts to the vehicle weight, cost, and schedule. If the load estimates turn out to be too low, there is significant risk of structural failure of the vehicle. This assessment used a combination of unsteady pressure-sensitive paint (uPSP), unsteady pressure transducers, and a dynamic force and moment balance to investigate the integration schemes used with limited unsteady pressure data by comparing them with direct integration of extremely dense fluctuating pressure measurements. An outfall of the assessment was to evaluate the potential of using the emerging uPSP technique in a production

  19. Optical measurement of acoustic radiation pressure of the near-field acoustic levitation through transparent object

    OpenAIRE

    Nakamura, Satoshi; Furusawa, Toshiaki; Sasao, Yasuhiro; Katsura, Kogure; Naoki, Kondo

    2013-01-01

    It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured the acoustic radiation pressure of the near-field acoustic levitation via pressure-sensitive paint.

  20. Organic Electroluminescent Sensor for Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Tomohide Niimi

    2012-10-01

    Full Text Available We have proposed a novel concept of a pressure sensor called electroluminescent pressure sensor (ELPS based on oxygen quenching of electroluminescence. The sensor was fabricated as an organic light-emitting device (OLED with phosphorescent dyes whose phosphorescence can be quenched by oxygenmolecules, and with a polymer electrode which permeates oxygen molecules. The sensor was a single-layer OLED with Platinum (II octaethylporphine (PtOEP doped into poly(vinylcarbazole (PVK as an oxygen sensitive emissive layer and poly(3,4-ethylenedioxythiophene mixed with poly(styrenesulfonate (PEDOT:PSS as an oxygen permeating polymer anode. The pressure sensitivity of the fabricated ELPS sample was equivalent to that of the sensor excited by an illumination light source. Moreover, the pressure sensitivity of the sensor is equivalent to that of conventional pressure-sensitive paint (PSP, which is an optical pressure sensor based on photoluminescence.

  1. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    Science.gov (United States)

    Krimi, Soufiene; Klier, Jens; Jonuscheit, Joachim; von Freymann, Georg; Urbansky, Ralph; Beigang, René

    2016-07-01

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

  2. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    International Nuclear Information System (INIS)

    Krimi, Soufiene; Beigang, René; Klier, Jens; Jonuscheit, Joachim; Freymann, Georg von; Urbansky, Ralph

    2016-01-01

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

  3. Study on the Fabrication of Paint-Type Si Quantum Dot-Sensitized Solar Cells

    Science.gov (United States)

    Seo, Hyunwoong; Son, Min-Kyu; Kim, Hee-Je; Wang, Yuting; Uchida, Giichiro; Kamataki, Kunihiro; Itagaki, Naho; Koga, Kazunori; Shiratani, Masaharu

    2013-10-01

    Quantum dots (QDs) have attracted much attention with their quantum characteristics in the research field of photochemical solar cells. Si QD was introduced as one of alternatives to conventional QD materials. However, their large particles could not penetrate inside TiO2 layer. Therefore, this work proposed the paint-type Si QD-sensitized solar cell. Its heat durability was suitable for the fabrication of paint-type solar cell. Si QDs were fabricated by multihollow discharge plasma chemical vapor deposition and characterized. The paste type, sintering temperature, and Si ratio were controlled and analyzed for better performance. Finally, its performance was enhanced by ZnS surface modification and the whole process was much simplified without sensitizing process.

  4. Synchronous Surface Pressure and Velocity Measurements of standard model in hypersonic flow

    Directory of Open Access Journals (Sweden)

    Zhijun Sun

    2018-01-01

    Full Text Available Experiments in the Hypersonic Wind tunnel of NUAA(NHW present synchronous measurements of bow shockwave and surface pressure of a standard blunt rotary model (AGARD HB-2, which was carried out in order to measure the Mach-5-flow above a blunt body by PIV (Particle Image Velocimetry as well as unsteady pressure around the rotary body. Titanium dioxide (Al2O3 Nano particles were seeded into the flow by a tailor-made container. With meticulous care designed optical path, the laser was guided into the vacuum experimental section. The transient pressure was obtained around model by using fast-responding pressure-sensitive paint (PSPsprayed on the model. All the experimental facilities were controlled by Series Pulse Generator to ensure that the data was time related. The PIV measurements of velocities in front of the detached bow shock agreed very well with the calculated value, with less than 3% difference compared to Pitot-pressure recordings. The velocity gradient contour described in accord with the detached bow shock that showed on schlieren. The PSP results presented good agreement with the reference data from previous studies. Our work involving studies of synchronous shock-wave and pressure measurements proved to be encouraging.

  5. XRF measurements of tin, copper and zinc in antifouling paints coated on leisure boats

    International Nuclear Information System (INIS)

    Ytreberg, Erik; Bighiu, Maria Alexandra; Lundgren, Lennart; Eklund, Britta

    2016-01-01

    Tributyltin (TBT) and other organotin compounds have been restricted for use on leisure boats since 1989 in the EU. Nonetheless, release of TBT is observed from leisure boats during hull maintenance work, such as pressure hosing. In this work, we used a handheld X-ray Fluorescence analyser (XRF) calibrated for antifouling paint matrixes to measure tin, copper and zinc in antifouling paints coated on leisure boats in Sweden. Our results show that over 10% of the leisure boats (n = 686) contain >400 μg/cm 2 of tin in their antifouling coatings. For comparison, one layer (40 μm dry film) of a TBT-paint equals ≈ 800 μg Sn/cm 2 . To our knowledge, tin has never been used in other forms than organotin (OT) in antifouling paints. Thus, even though the XRF analysis does not provide any information on the speciation of tin, the high concentrations indicate that these leisure boats still have OT coatings present on their hull. On several leisure boats we performed additional XRF measurements by progressively scraping off the top coatings and analysing each underlying layer. The XRF data show that when tin is detected, it is most likely present in coatings close to the hull with several layers of other coatings on top. Thus, leaching of OT compounds from the hull into the water is presumed to be negligible. The risk for environmental impacts arises during maintenance work such as scraping, blasting and high pressure hosing activities. The data also show that many boat owners apply excessive paint layers when following paint manufacturers recommendations. Moreover, high loads of copper were detected even on boats sailing in freshwater, despite the more than 20 year old ban, which poses an environmental risk that has not been addressed until now. - Highlights: • A new XRF application for analysing metals in antifouling paints has been used. • Almost 700 leisure boats were analysed for tin, copper and zinc. • Over 10% of the leisure boats contained high, >400

  6. Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix

    International Nuclear Information System (INIS)

    Zemlicka, J; Jakubek, J; Kroupa, M; Hradil, D; Hradilova, J; Mislerova, H

    2011-01-01

    Non-invasive techniques utilizing X-ray radiation offer a significant advantage in scientific investigations of painted arts and other cultural artefacts such as painted artworks or statues. In addition, there is also great demand for a mobile analytical and real-time imaging device given the fact that many fine arts cannot be transported. The highly sensitive hybrid semiconductor pixel detector, Timepix, is capable of detecting and resolving subtle and low-contrast differences in the inner composition of a wide variety of objects. Moreover, it is able to map the surface distribution of the contained elements. Several transmission and emission techniques are presented which have been proposed and tested for the analysis of painted artworks. This study focuses on the novel techniques of X-ray transmission radiography (conventional and energy sensitive) and X-ray induced fluorescence imaging (XRF) which can be realised at the table-top scale with the state-of-the-art pixel detector Timepix. Transmission radiography analyses the changes in the X-ray beam intensity caused by specific attenuation of different components in the sample. The conventional approach uses all energies from the source spectrum for the creation of the image while the energy sensitive alternative creates images in given energy intervals which enable identification and separation of materials. The XRF setup is based on the detection of characteristic radiation induced by X-ray photons through a pinhole geometry collimator. The XRF method is extremely sensitive to the material composition but it creates only surface maps of the elemental distribution. For the purpose of the analysis several sets of painted layers have been prepared in a restoration laboratory. The composition of these layers corresponds to those of real historical paintings from the 19 th century. An overview of the current status of our methods will be given with respect to the instrumentation and the application in the field of

  7. Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix

    Energy Technology Data Exchange (ETDEWEB)

    Zemlicka, J; Jakubek, J; Kroupa, M [Institute of Experimental and Applied Physics, Czech Technical University Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Hradil, D [Institute of Inorganic Chemistry, AS CR, v.v.i., ALMA, 50 68 Husinec-Oeez (Czech Republic); Hradilova, J; Mislerova, H, E-mail: jan.zemlicka@utef.cvut.cz [Academy of Fine Arts in Prague, ALMA, U Akademie 4, 170 2, Prague 7 (Czech Republic)

    2011-01-15

    Non-invasive techniques utilizing X-ray radiation offer a significant advantage in scientific investigations of painted arts and other cultural artefacts such as painted artworks or statues. In addition, there is also great demand for a mobile analytical and real-time imaging device given the fact that many fine arts cannot be transported. The highly sensitive hybrid semiconductor pixel detector, Timepix, is capable of detecting and resolving subtle and low-contrast differences in the inner composition of a wide variety of objects. Moreover, it is able to map the surface distribution of the contained elements. Several transmission and emission techniques are presented which have been proposed and tested for the analysis of painted artworks. This study focuses on the novel techniques of X-ray transmission radiography (conventional and energy sensitive) and X-ray induced fluorescence imaging (XRF) which can be realised at the table-top scale with the state-of-the-art pixel detector Timepix. Transmission radiography analyses the changes in the X-ray beam intensity caused by specific attenuation of different components in the sample. The conventional approach uses all energies from the source spectrum for the creation of the image while the energy sensitive alternative creates images in given energy intervals which enable identification and separation of materials. The XRF setup is based on the detection of characteristic radiation induced by X-ray photons through a pinhole geometry collimator. The XRF method is extremely sensitive to the material composition but it creates only surface maps of the elemental distribution. For the purpose of the analysis several sets of painted layers have been prepared in a restoration laboratory. The composition of these layers corresponds to those of real historical paintings from the 19{sup th} century. An overview of the current status of our methods will be given with respect to the instrumentation and the application in the field

  8. Statistics Analysis Measures Painting of Cooling Tower

    Directory of Open Access Journals (Sweden)

    A. Zacharopoulou

    2013-01-01

    Full Text Available This study refers to the cooling tower of Megalopolis (construction 1975 and protection from corrosive environment. The maintenance of the cooling tower took place in 2008. The cooling tower was badly damaged from corrosion of reinforcement. The parabolic cooling towers (factory of electrical power are a typical example of construction, which has a special aggressive environment. The protection of cooling towers is usually achieved through organic coatings. Because of the different environmental impacts on the internal and external side of the cooling tower, a different system of paint application is required. The present study refers to the damages caused by corrosion process. The corrosive environments, the application of this painting, the quality control process, the measures and statistics analysis, and the results were discussed in this study. In the process of quality control the following measurements were taken into consideration: (1 examination of the adhesion with the cross-cut test, (2 examination of the film thickness, and (3 controlling of the pull-off resistance for concrete substrates and paintings. Finally, this study refers to the correlations of measurements, analysis of failures in relation to the quality of repair, and rehabilitation of the cooling tower. Also this study made a first attempt to apply the specific corrosion inhibitors in such a large structure.

  9. A study on impact monitoring using a piezoelectric paint sensor

    International Nuclear Information System (INIS)

    Choi, Kyung Woo; Kang, Dong Hoon; Park, Seung Bok; Kang, Lae Hyong

    2015-01-01

    The piezoelectric paint sensor is a paint type sensor comprising of an epoxy and piezoelectric powder, which is the main component of a piezoelectric material. This sensor can be easily attached to any type of structure as compared to other sensors because it is viable to directly apply it on structures, as in the case with a typical paint. In this study, the capability of piezoelectric paint sensor for impact detection was evaluated. In Particular, the applications of the piezoelectric paint sensor for railroad vehicles were considered. There have been various cases reported about the damages caused by flying gravel to the under-cover of the railroad vehicle during operation. In order to prevent this, real-time monitoring of the large under-cover surface of the railroad vehicle is unavoidable. Under the assumption of vehicle application, sensor sensitivities were measured after multiple and prolonged exposure to thermal cycle environment -20⁓60 degrees Celsius). Sensitivity evaluation of paint sensor under environmental conditions was conducted in an aluminum specimen. In results, despite the small variations in sensitivity, we could confirm the applicability of this paint sensor for impact detection even after a severe environmental exposure test

  10. Line pressure effects on differential pressure measurements

    International Nuclear Information System (INIS)

    Neff, G.G.; Evans, R.P.

    1982-01-01

    The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

  11. Simultaneous velocity and pressure quantification using pressure-sensitive flow tracers in air

    Science.gov (United States)

    Zhang, Peng; Peterson, Sean; Porfiri, Maurizio

    2017-11-01

    Particle-based measurement techniques for assessing the velocity field of a fluid have advanced rapidly over the past two decades. Full-field pressure measurement techniques have remained elusive, however. In this work, we aim to demonstrate the possibility of direct simultaneous planar velocity and pressure measurement of a high speed aerodynamic flow by employing novel pressure-sensitive tracer particles for particle image velocimetry (PIV). Specifically, the velocity and pressure variations of an airflow through a converging-diverging channel are studied. Polystyrene microparticles embedded with a pressure-sensitive phosphorescent dye-platinum octaethylporphyrin (PtOEP)-are used as seeding particles. Due to the oxygen quenching effect, the emission lifetime of PtOEP is highly sensitive to the oxygen concentration, that is, the partial pressure of oxygen, in the air. Since the partial pressure of oxygen is linearly proportional to the air pressure, we can determine the air pressure through the phosphorescence emission lifetime of the dye. The velocity field is instead obtained using traditional PIV methods. The particles have a pressure resolution on the order of 1 kPa, which may be improved by optimizing the particle size and dye concentration to suit specific flow scenarios. This work was supported by the National Science Foundation under Grant Number CBET-1332204.

  12. Optical measurements of paintings and the creation of an artwork database for authenticity.

    Directory of Open Access Journals (Sweden)

    Seonhee Hwang

    Full Text Available Paintings have high cultural and commercial value, so that needs to be preserved. Many techniques have been attempted to analyze properties of paintings, including X-ray analysis and optical coherence tomography (OCT methods, and enable conservation of paintings from forgeries. In this paper, we suggest a simple and accurate optical analysis system to protect them from counterfeit which is comprised of fiber optics reflectance spectroscopy (FORS and line laser-based topographic analysis. The system is designed to fully cover the whole area of paintings regardless of its size for the accurate analysis. For additional assessments, a line laser-based high resolved OCT was utilized. Some forgeries were created by the experts from the three different styles of genuine paintings for the experiments. After measuring surface properties of paintings, we could observe the results from the genuine works and the forgeries have the distinctive characteristics. The forgeries could be distinguished maximally 76.5% with obtained RGB spectra by FORS and 100% by topographic analysis. Through the several executions, the reliability of the system was confirmed. We could verify that the measurement system is worthwhile for the conservation of the valuable paintings. To store the surface information of the paintings in micron scale, we created a numerical database. Consequently, we secured the databases of three different famous Korean paintings for accurate authenticity.

  13. Multimode fiber tip Fabry-Perot cavity for highly sensitive pressure measurement.

    Science.gov (United States)

    Chen, W P; Wang, D N; Xu, Ben; Zhao, C L; Chen, H F

    2017-03-23

    We demonstrate an optical Fabry-Perot interferometer fiber tip sensor based on an etched end of multimode fiber filled with ultraviolet adhesive. The fiber device is miniature (with diameter of less than 60 μm), robust and low cost, in a convenient reflection mode of operation, and has a very high gas pressure sensitivity of -40.94 nm/MPa, a large temperature sensitivity of 213 pm/°C within the range from 55 to 85 °C, and a relatively low temperature cross-sensitivity of 5.2 kPa/°C. This device has a high potential in monitoring environment of high pressure.

  14. Piezoelectric paint: characterization for further applications

    International Nuclear Information System (INIS)

    Yang, C; Fritzen, C-P

    2012-01-01

    Piezoelectric paint is a very attractive piezoelectric composite in many fields, such as non-destructive testing, or structural health monitoring. However, there are still many obstacles which restrict the real application of it. One of the main problems is that piezoelectric paint lacks a standard fabrication procedure, thus characterization is needed before use. The work presented here explores the characterization of piezoelectric paint. It starts with fabrication of samples with certain piezoelectric powder weight percentages. The microstructures of the samples are investigated by a scanning electron microscope; the results indicate that the fabrication method can produce high quality samples. This is followed by measurements of Young’s modulus and sensitivity. The piezoelectric charge constant d 31 is then deduced from the experimental data; the results agree well with a published result, which validates the effectiveness of the fabrication and characterization method. The characterized piezoelectric paint can expand its applications into different fields and therefore becomes a more promising and competitive smart material. (paper)

  15. Paint coating characterization for thermoelastic stress analysis of metallic materials

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2010-01-01

    In thermoelastic stress analysis (TSA) it is normal practice to coat metallic specimens with black paint to enhance and standardize the surface emissivity. It is assumed that the paint coating has no effect on the thermal emission from the specimen, but it is well known that the response is sensitive to paint coating thickness, particularly at higher frequencies. In this paper the effects of loading frequency and paint coating thickness on the thermoelastic response are investigated. The thermoelastic response is compared to theory, and optimum test conditions and coating characteristics are suggested. The motivation for the work is to develop a TSA-based means of residual stress assessment, where the measurement of much smaller temperature changes than those that are resolved in standard TSA is required; therefore the analysis is much more sensitive to the effects of the paint coating. However, the work presented in this paper is relevant to a wide range of TSA investigations and presents data that will be of interest to all practitioners of TSA

  16. Wet/dry film thickness measurement of paint by absorption spectroscopy with acousto-optic tunable filter spectrometer

    Science.gov (United States)

    Sinha, Pranay G.; Xiong, Xiangchun; Jin, Feng; Trivedi, Sudhir; Prasad, Narashima S.

    2005-08-01

    Controlling/monitoring the thickness of applied paint in real time is important to many situations including painting ship and submarine hulls in dry docks for maintaining health of ships and submarines against the harshness of the sea, in automobile and aerospace industries, and in a variety of other industries as a control sensor that plays significant role in product quality, process control, and cost control. Insufficient thickness results to inadequate protection while overspray leads to waste and pollution of the environment. A rugged instrumentation for the real time non-contact accurate measurement of wet and dry paint film thickness measurement will be immensely valuable. As paint is applied with several layers of the same or different type, thickness of each newly sprayed wet layer is of most interest, but measurement on dry paint is also useful. In this study, we use acousto-optic tunable filter-based near infrared spectrometer to obtain the absorption spectrum of layers of paint sprayed on sand blasted steel surface and thus measure the thickness of coating under both wet and dry situations. NIR spectra are obtained from 1100 to 2300 nm on four sample of different thickness of paint up to 127 micron. Partial least squares model built with the spectra shows good correlation with standard error of prediction within ~ 0.7 micron. Results indicate that the spectra also respond to the amount of organic solvent in the wet paint and can be used to monitor the degree of dryness of the paint in real time.

  17. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  18. Atomic Oxygen Treatment as a Method of Recovering Smoke Damaged Paintings. Revised

    Science.gov (United States)

    Rutledge, Sharon K.; Banks, Bruce A.; Forkapa, Mark; Stueber, Thomas; Sechkar, Edward; Malinowski, Kevin

    1999-01-01

    A noncontact technique is described that uses atomic oxygen, generated under low pressure in the presence of nitrogen, to remove soot and charred varnish from the surface of a painting. The process, which involves surface oxidation, permits control of the amount of surface material removed. The effectiveness of the process was evaluated by reflectance measurements from selected areas made during the removal of soot from acrylic gesso, ink on paper, and varnished oil paint substrates. For the latter substrate, treatment also involved the removal of damaged varnish and paint binder from the surface.

  19. Measurement of tritium in dial painting industry

    International Nuclear Information System (INIS)

    Sawant, J.V.; Rudran, Kamala

    1995-01-01

    Tritium in the form of polystyrene is used coated on zinc sulphide as the active component for the manufacture of self-luminous paint. To study the radiological implication of airborne tritium in the luminous paint industry air monitoring study was conducted by cold strip method and Andersen method. Airborne particulate in different locations in luminous paint (LP) building and background areas were observed to be associated with activity median aerodynamic diameter (AMAD) of 1.8 to 5.0 um. Dose to soft tissue and lungs and effective whole body dose were evaluated. (author). 6 refs., 2 figs., 4 tabs., 2 ills

  20. Large Aircraft Robotic Paint Stripping (LARPS) system and the high pressure water process

    Science.gov (United States)

    See, David W.; Hofacker, Scott A.; Stone, M. Anthony; Harbaugh, Darcy

    1993-03-01

    The aircraft maintenance industry is beset by new Environmental Protection Agency (EPA) guidelines on air emissions, Occupational Safety and Health Administration (OSHA) standards, dwindling labor markets, Federal Aviation Administration (FAA) safety guidelines, and increased operating costs. In light of these factors, the USAF's Wright Laboratory Manufacturing Technology Directorate and the Aircraft Division of the Oklahoma City Air Logistics Center initiated a MANTECH/REPTECH effort to automate an alternate paint removal method and eliminate the current manual methylene chloride chemical stripping methods. This paper presents some of the background and history of the LARPS program, describes the LARPS system, documents the projected operational flow, quantifies some of the projected system benefits and describes the High Pressure Water Stripping Process. Certification of an alternative paint removal method to replace the current chemical process is being performed in two phases: Process Optimization and Process Validation. This paper also presents the results of the Process Optimization for metal substrates. Data on the coating removal rate, residual stresses, surface roughness, preliminary process envelopes, and technical plans for process Validation Testing will be discussed.

  1. Design of Diaphragm Based MEMS Pressure Sensor with Sensitivity Analysis for Environmental Applications

    Directory of Open Access Journals (Sweden)

    A. Nallathambi

    2015-05-01

    Full Text Available In this paper Micro-electromechanical System (MEMS diaphragm based pressure sensor for environmental applications is discussed. The main focus of this paper is to design, simulate and analyze the sensitivity of MEMS based diaphragm using different structures to measure the low and high pressure values. The simulation is done through the finite element tool and specifications related the maximum convinced stress; deflection and sensitivity of the diaphragms have been analyzed using the software INTELLISUITE 8.7v. The change in pressure is to bending of the diaphragm that modifies the measured displacement between the substrate and the diaphragm. This change in displacement gives the measure of the pressure in that environment. The design of these studies can be used to improve the sensitivity of these devices. Here the diaphragm based pressure sensor produced better displacement, sensitivity and stress output responses are obtained from the square diaphragm. The pressure range from 0.6 MPa to 25 MPa and its maximum displacement is accordingly 59 mm over a pressure range of 0 to 2 MPa. Its sensitivity is therefore 2.35 [10E-12/Pa].

  2. Blood pressure and pain sensitivity in children and adolescents.

    Science.gov (United States)

    Drouin, Sammantha; McGrath, Jennifer J

    2013-06-01

    Elevated blood pressure is associated with diminished pain sensitivity. While this finding is well established in adults, it is less clear when the relation between blood pressure and pain sensitivity emerges across the life course. Evidence suggests this phenomenon may exist during childhood. Children (N = 309; 56% boys) aged 10-15 years and their parents participated. Blood pressure readings were taken during a resting baseline. Maximum pain intensity was rated using a visual analogue scale (rated 0-10) in response to a finger prick pain induction. Parent-measured resting blood pressure was inversely associated with boys' pain ratings only. Cross-sectionally, lower pain ratings were related to higher SBP, univariately. Longitudinally, pain ratings predicted higher DBP, even after controlling for covariates. Determining when and how the relation between blood pressure and pain sensitivity emerges may elucidate the pathophysiology of hypertension. Copyright © 2013 Society for Psychophysiological Research.

  3. On-line pressure measurement using scanning systems

    International Nuclear Information System (INIS)

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  4. Extremely-high vacuum pressure measurement by laser ionization

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    Laser ionization method has the very high sensitivity for detecting atoms and molecules. Hurst et al. successfully detected a single Cs atom by means of resonance ionization spectroscopy developed by them. Noting this high sensitivity, the authors have attempted to apply the laser ionization method to measure gas pressure, particularly in the range down to extremely high vacuum. At present, hot cathode ionization gauges are used for measuring gas pressure down to ultrahigh vacuum, however, those have a number of disadvantages. The pressure measurement using lasers does not have such disadvantages. The pressure measurement utilizing the laser ionization method is based on the principle that when laser beam is focused through a lens, the amount of atom or molecule ions generated in the focused space region is proportional to gas pressure. In this paper, the experimental results are presented on the nonresonant multiphoton ionization characteristics of various kinds of gases, the ion detection system with high sensitivity and an extremely high vacuum system prepared for the laser ionization experiment. (K.I.)

  5. Occupational hazards and safety measures amongst the paint factory workers in lagos, Nigeria.

    Science.gov (United States)

    Awodele, Olufunsho; Popoola, Temidayo D; Ogbudu, Bawo S; Akinyede, Akin; Coker, Herbert A B; Akintonwa, Alade

    2014-06-01

    The manufacture of paint involves a variety of processes that present with medical hazards. Safety initiatives are hence introduced to limit hazard exposures and promote workplace safety. This aim of this study is to assess the use of available control measures/initiatives in selected paint factories in Lagos West Senatorial District, Nigeria. A total of 400 randomly selected paint factory workers were involved in the study. A well-structured World Health Organization standard questionnaire was designed and distributed to the workers to elicit information on awareness to occupational hazards, use of personal protective devices, and commonly experienced adverse symptoms. Urine samples were obtained from 50 workers randomly selected from these 400 participants, and the concentrations of the heavy metals (lead, cadmium, arsenic, and chromium) were determined using atomic absorption spectroscopy. The results show that 72.5% of the respondents are aware of the hazards associated with their jobs; 30% have had formal training on hazards and safety measures; 40% do not use personal protective devices, and 90% of the respondents reported symptoms relating to hazard exposure. There was a statistically significant (p metal concentrations in the urine samples obtained from paint factory workers as compared with nonfactory workers. The need to develop effective frameworks that will initiate the integration and ensure implementation of safety regulations in paint factories is evident. Where these exist, there is a need to promote adherence to these practice guidelines.

  6. Measurements of Crossflow Instability Modes for HIFiRE 5 at Angle of Attack

    Science.gov (United States)

    2017-11-15

    First, the new model accommodated IR heating measurements. The IR method alleviates roughness and steps induced by temperature-sensitive paint, and it...dominated by the strongly inflected boundary layer in this region. This inflection is due to the convergence of flow from the higher-pressure sides of

  7. Ultrahigh Sensitivity Piezoresistive Pressure Sensors for Detection of Tiny Pressure.

    Science.gov (United States)

    Li, Hongwei; Wu, Kunjie; Xu, Zeyang; Wang, Zhongwu; Meng, Yancheng; Li, Liqiang

    2018-05-31

    High sensitivity pressure sensors are crucial for the ultra-sensitive touch technology and E-skin, especially at the tiny pressure range below 100 Pa. However, it is highly challenging to substantially promote sensitivity beyond the current level at several to two hundred kPa -1 , and to improve the detection limit lower than 0.1 Pa, which is significant for the development of pressure sensors toward ultrasensitive and highly precise detection. Here, we develop an efficient strategy to greatly improve the sensitivity near to 2000 kPa -1 by using short channel coplanar device structure and sharp microstructure, which is systematically proposed for the first time and rationalized by the mathematic calculation and analysis. Significantly, benefiting from the ultrahigh sensitivity, the detection limit is improved to be as small as 0.075 Pa. The sensitivity and detection limit are both superior to the current levels, and far surpass the function of human skin. Furthermore, the sensor shows fast response time (50 μs), excellent reproducibility and stability, and low power consumption. Remarkably, the sensor shows excellent detection capacity in the tiny pressure range including LED switching with a pressure of 7 Pa, ringtone (2-20 Pa) recognition, and ultrasensitive (0.1 Pa) electronic glove. This work represents a performance and strategic progress in the field of pressure sensing.

  8. Environmental coefficients of the free-field sensitivity of measurement microphones

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Cutanda Henriquez, Vicente; Torras-Rosell, Antoni

    2017-01-01

    The sensitivity of measurement microphones, both pressure and free field, is affected by changes in the environmental conditions, mainly temperature and static pressure. Static pressure and temperature coefficients for the pressure sensitivity have been the object of previous studies focused...... on Laboratory Standard microphones and few working standard microphones. The literature describes frequency dependent values for these coefficients which are used for calibration purposes. However, there is no description of the environmental coefficients of the free-field sensitivity though there have been...... some implementations that attempt to take care of the differences between the coefficients for the two types of sensitivities. Measuring the coefficients in a free field poses some challeng; it is not so easy to change neither the static pressure nor the temperature inside anechoic room within...

  9. 21 CFR 175.125 - Pressure-sensitive adhesives.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Pressure-sensitive adhesives. 175.125 Section 175...) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES AND COMPONENTS OF COATINGS Substances for Use Only as Components of Adhesives § 175.125 Pressure-sensitive adhesives. Pressure-sensitive...

  10. Sensitivity enhancement of fiber loop cavity ring-down pressure sensor.

    Science.gov (United States)

    Jiang, Yajun; Yang, Dexing; Tang, Daqing; Zhao, Jianlin

    2009-11-10

    We present a theoretical and experimental study on sensitivity enhancement of a fiber-loop cavity ring-down pressure sensor. The cladding of the sensing fiber is etched in hydrofluoric acid solution to enhance its sensitivity. The experimental results demonstrate that the pressure applied on the sensing fiber is linearly proportional to the difference between the reciprocals of the ring-down time with and without pressure, and the relative sensitivity exponentially increases with decreasing the cladding diameter. When the sensing fiber is etched to 41.15 microm, its sensitivity is about 36 times that of nonetched fiber in the range of 0 to 32.5 MPa. The measured relative standard deviation of the ring-down time is about 0.15% and, correspondingly, the least detectable loss is about 0.00069 dB.

  11. LOFT fuel rod pressure measurement

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-01-01

    Pressure sensors selected for measuring fuel rod pressure within the LOFT reactor exhibited stable, repeatable operating characteristics during calibrations at temperatures up to 800 0 F and pressures to 2500 psig. All sensors have a nominal sensitivity of .5 millivolts per psi, decreasing monotonically with temperature. Output signal increases linearly with increasing pressure up to 2000 psig. For imposed slow and rapid temperature variations and for pressure applied during these tests, the sensor indicates a pressure at variance with the actual value by up to 15% of reading. However, the imposed temperature rates of change often exceeded the value of -10 0 F/sec. specified for LOFT. The series of tests in an autoclave permit creation of an environment most closely resembling sensor operating conditions within LOFT. For multiple blowdowns and for longtime durations the sensor continued to provide pressure-related output signals. For temperature rates up to -87 0 F/sec, the indicated pressure measurement error remained less than 13% of reading. Adverse effects caused by heating the 1/16 inch O.D. signal cable to 800 0 F contributed only insignificantly to the noted pressure measurement error

  12. Measurement of adhesion properties between topcoat paint and metallized/galvanized steel with surface energy measurement equipment.

    Science.gov (United States)

    2013-09-01

    The objectives of this research project are: (1) Compare the adhesion properties of NEPCOAT-approved topcoat paint over : metallized or galvanized steel. Use surface-energy measuring technique to characterize the wetting properties of the liqui...

  13. Cleaning of Easel Paintings: An Overview

    International Nuclear Information System (INIS)

    Bordalo, R.; Morais, P.J.; Gouveia, H.; Young, C.

    2006-01-01

    The application of laser cleaning to paintings is relatively recent despite its use on stone-based materials for over 30 years. The cleaning of paintings is of high importance, because it is the least reversible invasive intervention, as well as the most usual of all conservation treatments. Paintings are multilayer system of heterogeneous nature, often very sensitive and inherent difficult to clean. Being a noncontact method, laser cleaning has advantages compared to alternative techniques. Over the last decade, there have been important research studies and advances. However, they are far from sufficient to study the effects on painting materials and to establish the best parameters for each material under investigation. This paper presents a historical overview of the application of laser technology to the cleaning of paintings giving special emphasis on the research of the last decade. An overview of the current research into the interaction between the radiation and the different painting materials (varnish, pigments, and medium) is also given. The pigment's mechanisms of discoloration and the presence of media as a variable factor in the discoloration of pigments are discussed.

  14. Measuring Viscosities of Gases at Atmospheric Pressure

    Science.gov (United States)

    Singh, Jag J.; Mall, Gerald H.; Hoshang, Chegini

    1987-01-01

    Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

  15. Finite Element Modeling of Vibrations in Canvas Paintings

    NARCIS (Netherlands)

    Chiriboga Arroyo, P.G.

    2013-01-01

    Preventing vibration damage from occurring to valuable and sensitive canvas paintings is of main concern for museums and art conservation institutions. This concern has grown in recent years due to the increasing demand of paintings for exhibitions worldwide and the concomitant need for their

  16. A Manganin Thin Film Ultra-High Pressure Sensor for Microscale Detonation Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Guodong Zhang

    2018-03-01

    Full Text Available With the development of energetic materials (EMs and microelectromechanical systems (MEMS initiating explosive devices, the measurement of detonation pressure generated by EMs in the microscale has become a pressing need. This paper develops a manganin thin film ultra-high pressure sensor based on MEMS technology for measuring the output pressure from micro-detonator. A reliable coefficient is proposed for designing the sensor’s sensitive element better. The sensor employs sandwich structure: the substrate uses a 0.5 mm thick alumina ceramic, the manganin sensitive element with a size of 0.2 mm × 0.1 mm × 2 μm and copper electrodes of 2 μm thick are sputtered sequentially on the substrate, and a 25 μm thick insulating layer of polyimide is wrapped on the sensitive element. The static test shows that the piezoresistive coefficient of manganin thin film is 0.0125 GPa−1. The dynamic experiment indicates that the detonation pressure of micro-detonator is 12.66 GPa, and the response time of the sensor is 37 ns. In a word, the sensor developed in this study is suitable for measuring ultra-high pressure in microscale and has a shorter response time than that of foil-like manganin gauges. Simultaneously, this study could be beneficial to research on ultra-high-pressure sensors with smaller size.

  17. Dynamic pressure sensitivity determination with Mach number method

    Science.gov (United States)

    Sarraf, Christophe; Damion, Jean-Pierre

    2018-05-01

    Measurements of pressure in fast transient conditions are often performed even if the dynamic characteristic of the transducer are not traceable to international standards. Moreover, the question of a primary standard in dynamic pressure is still open, especially for gaseous applications. The question is to improve dynamic standards in order to respond to expressed industrial needs. In this paper, the method proposed in the EMRP IND09 ‘Dynamic’ project, which can be called the ‘ideal shock tube method’, is compared with the ‘collective standard method’ currently used in the Laboratoire de Métrologie Dynamique (LNE/ENSAM). The input is a step of pressure generated by a shock tube. The transducer is a piezoelectric pressure sensor. With the ‘ideal shock tube method’ the sensitivity of a pressure sensor is first determined dynamically. This method requires a shock tube implemented with piezoelectric shock wave detectors. The measurement of the Mach number in the tube allows an evaluation of the incident pressure amplitude of a step using a theoretical 1D model of the shock tube. Heat transfer, other actual effects and effects of the shock tube imperfections are not taken into account. The amplitude of the pressure step is then used to determine the sensitivity in dynamic conditions. The second method uses a frequency bandwidth comparison to determine pressure at frequencies from quasi-static conditions, traceable to static pressure standards, to higher frequencies (up to 10 kHz). The measurand is also a step of pressure generated by a supposed ideal shock tube or a fast-opening device. The results are provided as a transfer function with an uncertainty budget assigned to a frequency range, also deliverable frequency by frequency. The largest uncertainty in the bandwidth of comparison is used to trace the final pressure step level measured in dynamic conditions, owing that this pressure is not measurable in a steady state on a shock tube. A reference

  18. A novel XRF method to measure environmental release of copper and zinc from antifouling paints.

    Science.gov (United States)

    Ytreberg, Erik; Lagerström, Maria; Holmqvist, Albin; Eklund, Britta; Elwing, Hans; Dahlström, Magnus; Dahl, Peter; Dahlström, Mia

    2017-06-01

    The release of copper (Cu) and zinc (Zn) from vessels and leisure crafts coated with antifouling paints can pose a threat to water quality in semi-enclosed areas such as harbors and marinas as well as to coastal archipelagos. However, no reliable, practical and low-cost method exists to measure the direct release of metals from antifouling paints. Therefore, the paint industry and regulatory authorities are obliged to use release rate measurements derived from either mathematical models or from laboratory studies. To bridge this gap, we have developed a novel method using a handheld X-Ray Fluorescence spectrometer (XRF) to determine the cumulative release of Cu and Zn from antifouling paints. The results showed a strong linear relationship between XRF K α net intensities and metal concentrations, as determined by ICP-MS. The release of Cu and Zn were determined for coated panels exposed in harbors located in the Baltic Sea and in Kattegat. The field study showed salinity to have a strong impact on the release of Cu, i.e. the release increased with salinity. Contrary, the effect of salinity on Zn was not as evident. As exemplified in this work, the XRF method also makes it possible to identify the governing parameters to the release of Cu and Zn, e.g. salinity and type of paint formulation. Thus, the XRF method can be used to measure environmentally relevant releases of metallic compounds to design more efficient and optimized antifouling coatings. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  20. Applications of pressure-sensitive dielectric elastomer sensors

    Science.gov (United States)

    Böse, Holger; Ocak, Deniz; Ehrlich, Johannes

    2016-04-01

    Dielectric elastomer sensors for the measurement of compression loads with high sensitivity are described. The basic design of the sensors exhibits two profiled surfaces between which an elastomer film is confined. All components of the sensor were prepared with silicone whose stiffness can be varied in a wide range. Depending on details of the sensor design, various effects contribute to the enhancement of the capacitance. The intermediate elastomer film is stretched upon compression and electrode layers on the elastomer profiles and in the elastomer film approach each other. Different designs of the pressure sensor give rise to very different sensor characteristics in terms of the dependence of electric capacitance on compression force. Due to their inherent flexibility, the pressure sensors can be used on compliant substrates such as seats or beds or on the human body. This gives rise to numerous possible applications. The contribution describes also some examples of possible sensor applications. A glove was equipped with various sensors positioned at the finger tips. When grabbing an object with the glove, the sensors can detect the gripping forces of the individual fingers with high sensitivity. In a demonstrator of the glove equipped with seven sensors, the capacitances representing the gripping forces are recorded on a display. In another application example, a lower limb prosthesis was equipped with a pressure sensor to detect the load on the remaining part of the leg and the load is displayed in terms of the measured capacitance. The benefit of such sensors is to detect an eventual overload in order to prevent possible pressure sores. A third example introduces a seat load sensor system based on four extended pressure sensor mats. The sensor system detects the load distribution of a person on the seat. The examples emphasize the high performance of the new pressure sensor technology.

  1. Measurement of fast transient pressures

    International Nuclear Information System (INIS)

    Procaccia, Henri

    1978-01-01

    The accuracy, reliability and sensitivity of a pressure transducers define its principal static characteristics. When the quantity measured varies with time, the measurement carries a dynamic error and a delay depending on the frequency of this variation. Hence, when fast pressure changes in a fluid have to be determined, different kinds of pressure transducers can be used depending on their inherent dynamic characteristics which must be compared with those of the transient phenomenon to be analysed. The text describes the pressure transducers generally employed in industry for analysing such phenomenon and gives two practical applications developed in the EDF: the first submits the measurements and results of pump cavitation tests carried out at the Vitry II EDF power station; the second deals with hammer blows particularly noticed in nuclear power stations and required the use of transducers of exceptionally high performance such as strain gauge transducers and piezoelectric transducers (response time within 1m sec.) [fr

  2. A test to measure the minimum burning pressure of water-based commercial explosives and their precursors

    Energy Technology Data Exchange (ETDEWEB)

    Turcotte, R.; Feng, H.; Badeen, C.M.; Goldthorp, S.; Johnson, C. [Natural Resources Canada, Ottawa, ON (Canada). Canadian Explosives Research Laboratory; Chan, S.K. [Orica Canada Inc., Brownsburg-Chatham, PQ (Canada)

    2009-05-15

    This paper described a testing protocol developed to measure the minimum burning pressure (MBP) of ammonium nitrate water-based emulsions (AWEs). Oxidizer solutions were prepared in a stainless steel beaker. A modified commercial mixer was used to emulsify the oil-surfactant phase with the oxidizer solutions and blend dry ingredients. Five high water content AWEs were then prepared and placed in pressurized vessels. Samples were ignited using a straight length of nichrome wire. Emulsion samples were transferred into a cylindrical test cell painted with non-conductive paint. Copper conductor leg-wires were connected to electrodes passing through the body of the vessel. When samples were equilibrated to the desired initial pressure, a constant current was supplied to the hot wire. Solid state relays were used to switch the current power supply on and off. Hot wire voltage signals were used to obtain temperature profiles for onset and ignition temperatures. The procedure to perform the MBP measurements was based on 3 types of classifying events, namely (1) no reaction, (2) partial reaction, and (3) slow decomposition. Results of the tests demonstrated that the 5 emulsions exhibited large differences in respective MBP values. Data from the study will be used to develop standards for the authorization of high explosives in Canada. 15 refs., 1 tab., 3 figs.

  3. Correction of static pressure on a research aircraft in accelerated flight using differential pressure measurements

    Directory of Open Access Journals (Sweden)

    A. R. Rodi

    2012-11-01

    Full Text Available A method is described that estimates the error in the static pressure measurement on an aircraft from differential pressure measurements on the hemispherical surface of a Rosemount model 858AJ air velocity probe mounted on a boom ahead of the aircraft. The theoretical predictions for how the pressure should vary over the surface of the hemisphere, involving an unknown sensitivity parameter, leads to a set of equations that can be solved for the unknowns – angle of attack, angle of sideslip, dynamic pressure and the error in static pressure – if the sensitivity factor can be determined. The sensitivity factor was determined on the University of Wyoming King Air research aircraft by comparisons with the error measured with a carefully designed sonde towed on connecting tubing behind the aircraft – a trailing cone – and the result was shown to have a precision of about ±10 Pa over a wide range of conditions, including various altitudes, power settings, and gear and flap extensions. Under accelerated flight conditions, geometric altitude data from a combined Global Navigation Satellite System (GNSS and inertial measurement unit (IMU system are used to estimate acceleration effects on the error, and the algorithm is shown to predict corrections to a precision of better than ±20 Pa under those conditions. Some limiting factors affecting the precision of static pressure measurement on a research aircraft are discussed.

  4. Measurements of tritium for radiological protection purposes in dial painting industry

    International Nuclear Information System (INIS)

    Sawant, J.V.; Rudran, Kamala; Pillai, K.C.

    1990-01-01

    Tritium is used as the active component in self-luminous paint. During dial painting process luminous paints releases tritium in air, causing air contamination. In the present paper results of a preliminary study on air monitoring and estimation of air samples in a local watch industry are given. (author). 5 refs., 2 t abs

  5. Microscale radiocarbon dating of paintings

    International Nuclear Information System (INIS)

    Hendriks, Laura; Hajdas, Irka; McIntyre, Cameron; Kueffner, Markus; Ferreira, Ester S.B.; Scherrer, Nadim C.

    2016-01-01

    In this paper, radiocarbon dating of paintings using minimal sample sizes has been investigated, in an effort to address the problem of limited access to sample material in paintings. 14 C analyses were conducted on signed and dated paintings from two Swiss artists of the twentieth century. The selected paintings dated from the 1930s and 1960s, provided the opportunity to evaluate the dating accuracy on paintings realized before and after 1950 AD when the 14 C bomb peak was created, as a result of the nuclear tests conducted in the 1950/1960s. The work focused on the one hand on minimizing the size of the canvas sample required for accelerator mass spectrometer radiocarbon measurement on the gas ion source of the MICADAS and, on the other hand, on testing the possibility of dating the organic binder of the paint. Following careful characterization of the paint composition by X-ray fluorescence spectroscopy, Fourier transformed infrared spectroscopy, and Raman spectroscopy, paints containing no other carbon source than the natural organic binder were identified and dated. (orig.)

  6. Microscale radiocarbon dating of paintings

    Energy Technology Data Exchange (ETDEWEB)

    Hendriks, Laura; Hajdas, Irka; McIntyre, Cameron [ETH Zurich, Ion Beam Physics, Zurich (Switzerland); Kueffner, Markus; Ferreira, Ester S.B. [SIK-ISEA, Zurich, Zurich (Switzerland); Scherrer, Nadim C. [Bern University of Applied Sciences, HKB, Bern (Switzerland)

    2016-03-15

    In this paper, radiocarbon dating of paintings using minimal sample sizes has been investigated, in an effort to address the problem of limited access to sample material in paintings. {sup 14}C analyses were conducted on signed and dated paintings from two Swiss artists of the twentieth century. The selected paintings dated from the 1930s and 1960s, provided the opportunity to evaluate the dating accuracy on paintings realized before and after 1950 AD when the {sup 14}C bomb peak was created, as a result of the nuclear tests conducted in the 1950/1960s. The work focused on the one hand on minimizing the size of the canvas sample required for accelerator mass spectrometer radiocarbon measurement on the gas ion source of the MICADAS and, on the other hand, on testing the possibility of dating the organic binder of the paint. Following careful characterization of the paint composition by X-ray fluorescence spectroscopy, Fourier transformed infrared spectroscopy, and Raman spectroscopy, paints containing no other carbon source than the natural organic binder were identified and dated. (orig.)

  7. The Measurement of the moisture transfer properties of paint films using the cup method

    NARCIS (Netherlands)

    Goossens, E.L.J.; Zanden, van der A.J.J.; Spoel, van der W.H.

    2004-01-01

    The cup method has been used to measure the diffusion coefficient (or permeability) of water in free paint films. A dependence on the layer thickness of the diffusion coefficient could not be measured. The diffusion coefficient depends strongly on the relative humidity. The measured diffusion

  8. Acceleration sensitivity of micromachined pressure sensors

    Science.gov (United States)

    August, Richard; Maudie, Theresa; Miller, Todd F.; Thompson, Erik

    1999-08-01

    Pressure sensors serve a variety of automotive applications, some which may experience high levels of acceleration such as tire pressure monitoring. To design pressure sensors for high acceleration environments it is important to understand their sensitivity to acceleration especially if thick encapsulation layers are used to isolate the device from the hostile environment in which they reside. This paper describes a modeling approach to determine their sensitivity to acceleration that is very general and is applicable to different device designs and configurations. It also describes the results of device testing of a capacitive surface micromachined pressure sensor at constant acceleration levels from 500 to 2000 g's.

  9. The Evaluation of Momentum Flux to Estimate Exposure From Spray Painting Operations

    National Research Council Canada - National Science Library

    Blazicko, Brian

    1998-01-01

    .... The model was tested with an anthropometric, 73 inch mechanical mannequin spraying nonvolatile oil on a flat plate in a paint booth while using a high volume, low pressure (HVLP) spray paint gun...

  10. Ambient pressure sensitivity of microbubbles investigated through a parameter study

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Measurements on microbubbles clearly indicate a relation between the ambient pressure and the acoustic behavior of the bubble. The purpose of this study was to optimize the sensitivity of ambient pressure measurements, using the subharmonic component, through microbubble response simulations....... The behavior of two microbubbles corresponding to two different contrast agents was investigated as a function of driving pulse and ambient overpressure, pov. Simulations of Levovist using a rectangular driving pulse show an almost linear reduction in the subharmonic component as pov is increased. For a 20...... found, although the reduction is not completely linear as a function of the ambient pressure....

  11. Reliability and validity of pressure and temporal parameters recorded using a pressure-sensitive insole during running

    NARCIS (Netherlands)

    Mann, R.; Malisoux, L.; Brunner, R.; Gette, P.; Urhausen, A.; Statham, A.; Meijer, K.; Theisen, D.

    2014-01-01

    Running biomechanics has received increasing interest in recent literature on running-related injuries, calling for new, portable methods for large-scale measurements. Our aims were to define running strike pattern based on output of a new pressure-sensitive measurement device, the Runalyser, and to

  12. A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements

    International Nuclear Information System (INIS)

    Dennison, Christopher R; Wild, Peter M; Wilson, David R; Cripton, Peter A

    2008-01-01

    We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm 2 , respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics

  13. Landscape Painting. Rewriting Painting in the Postmedium Condition

    Directory of Open Access Journals (Sweden)

    Gal, Nissim

    2011-02-01

    Full Text Available Is landscape painting still relevant today? To answer this question the article examines the work of the contemporary artist Yehudit Sasportas. Sasporas offers a unique kind of written-drawn landscape painting that moves between the manual and the mechanical. The theoretical perspectives from which it is approached are taken, among others, from Plato, Heidegger and Derrida on the issue of writing. Sasportas painting, which may be characterized as "painting under erasure" or "Landscape Painting", serves as a key to understanding the status of painting as a relevant medium, not because it defines medium according to the modernist Greenbergian formula, but because it enables an understanding of painting as a field that exists in a variety of media. Painting as a field, in Sasportas's art, works and lives within various techniques and materials, even when it includes within itself a melancholic mark indicating doubt about its own relevance.

  14. PMT signal increase using a wavelength shifting paint

    Energy Technology Data Exchange (ETDEWEB)

    Allada, K. [Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Hurlbut, Ch. [Eljen Technology, Sweetwater, TX 79556 (United States); Ou, L.; Schmookler, B. [Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Shahinyan, A. [Yerevan Physics Institute, Yerevan (Armenia); Wojtsekhowski, B., E-mail: bogdanw@jlab.org [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)

    2015-05-11

    We report a 1.65 times increase of the PMT signal and a simple procedure of application of a new wavelength shifting (WLS) paint for PMTs with non-UV-transparent windows. Samples of four different WLS paints, made from hydrocarbon polymers and organic fluors, were tested on a 5-in. PMT (ET 9390KB) using Cherenkov radiation produced in fused silica disks by {sup 106}Ru electrons on a ‘table-top’ setup. The best performing paint was employed on two different types of 5-in. PMTs (ET 9390KB and XP4572B), installed in atmospheric pressure CO{sub 2} gas Cherenkov detectors, and tested using GeV electrons.

  15. A method enabling simultaneous pressure and temperature measurement using a single piezoresistive MEMS pressure sensor

    International Nuclear Information System (INIS)

    Frantlović, Miloš; Stanković, Srđan; Jokić, Ivana; Lazić, Žarko; Smiljanić, Milče; Obradov, Marko; Vukelić, Branko; Jakšić, Zoran

    2016-01-01

    In this paper we present a high-performance, simple and low-cost method for simultaneous measurement of pressure and temperature using a single piezoresistive MEMS pressure sensor. The proposed measurement method utilizes the parasitic temperature sensitivity of the sensing element for both pressure measurement correction and temperature measurement. A parametric mathematical model of the sensor was established and its parameters were calculated using the obtained characterization data. Based on the model, a real-time sensor correction for both pressure and temperature measurements was implemented in a target measurement system. The proposed method was verified experimentally on a group of typical industrial-grade piezoresistive sensors. The obtained results indicate that the method enables the pressure measurement performance to exceed that of typical digital industrial pressure transmitters, achieving at the same time the temperature measurement performance comparable to industrial-grade platinum resistance temperature sensors. The presented work is directly applicable in industrial instrumentation, where it can add temperature measurement capability to the existing pressure measurement instruments, requiring little or no additional hardware, and without adverse effects on pressure measurement performance. (paper)

  16. Micro packaged MEMS pressure sensor for intracranial pressure measurement

    International Nuclear Information System (INIS)

    Liu Xiong; Yao Yan; Ma Jiahao; Zhang Zhaohua; Zhang Yanhang; Wang Qian; Ren Tianling

    2015-01-01

    This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm 2 . It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm 2 . In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm 2 . Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10 −2 mV/kPa. (paper)

  17. Painting recognition with smartphones equipped with inertial measurement unit

    Science.gov (United States)

    Masiero, Andrea; Guarnieri, Alberto; Pirotti, Francesco; Vettore, Antonio

    2015-06-01

    Recently, several works have been proposed in the literature to take advantage of the diffusion of smartphones to improve people experience during museum visits. The rationale is that of substituting traditional written/audio guides with interactive electronic guides usable on a mobile phone. Augmented reality systems are usually considered to make the use of such electronic guides more effective for the user. The main goal of such augmented reality system (i.e. providing the user with the information of his/her interest) is usually achieved by properly executing the following three tasks: recognizing the object of interest to the user, retrieving the most relevant information about it, properly presenting the retrieved information. This paper focuses on the first task: we consider the problem of painting recognition by means of measure- ments provided by a smartphone. We assume that the user acquires one image of the painting of interest with the standard camera of the device. This image is compared with a set of reference images of the museum objects in order to recognize the object of interest to the user. Since comparing images taken in different conditions can lead to unsatisfactory recognition results, the acquired image is typically properly transformed in order to improve the results of the recognition system: first, the system estimates the homography between properly matched features in the two images. Then, the user image is transformed accordingly to the estimated homography. Finally, it is compared with the reference one. This work proposes a novel method to exploit inertial measurement unit (IMU) measurements to improve the system performance, in particular in terms of computational load reduction: IMU measurements are exploited to reduce both the computational burden required to estimate the transformation to be applied to the user image, and the number of reference images to be compared with it.

  18. Pressure pain sensitivity: A new method of stress measurement in patients with ischemic heart disease

    DEFF Research Database (Denmark)

    Bergmann, Natasha; Ballegaard, Søren; Holmager, Pernille

    2013-01-01

    to induce hyperalgesia.The aim of the present study was to evaluate hyperalgesia by pressure pain sensitivity (PPS) in patients with IHD, and compare PPS to questionnaires measuring depressive symptoms, reduced psychological wellbeing, and QOL as markers of stress. Design. A cross-sectional study of 361......Abstract Background. Chronic stress is prevalent in patients with ischemic heart disease (IHD) and worsens the long-term prognosis. Chronic stress is vaguely defined, but is associated with depressive symptoms, reduced psychological wellbeing, and reduced quality of life (QOL). Stress seems...... subjects with IHD. Methods. PPS was measured on the sternum, and compared to the questionnaires: Clinical stress symptoms score (CSS), Major Depression Inventory (MDI), WHO-5 Wellbeing Index, and SF-36 QOL score. Results. PPS correlated to CSS (r = 0.20, p

  19. A Quad-Cantilevered Plate micro-sensor for intracranial pressure measurement.

    Science.gov (United States)

    Lalkov, Vasko; Qasaimeh, Mohammad A

    2017-07-01

    This paper proposes a new design for pressure-sensing micro-plate platform to bring higher sensitivity to a pressure sensor based on piezoresistive MEMS sensing mechanism. The proposed design is composed of a suspended plate having four stepped cantilever beams connected to its corners, and thus defined as Quad-Cantilevered Plate (QCP). Finite element analysis was performed to determine the optimal design for sensitivity and structural stability under a range of applied forces. Furthermore, a piezoresistive analysis was performed to calculate sensor sensitivity. Both the maximum stress and the change in resistance of the piezoresistor associated with the QCP were found to be higher compared to previously published designs, and linearly related to the applied pressure as desired. Therefore, the QCP demonstrates greater sensitivity, and could be potentially used as an efficient pressure sensor for intracranial pressure measurement.

  20. Applications of optical coherence tomography in the non-contact assessment of automotive paints

    Science.gov (United States)

    Lawman, Samuel; Zhang, Jinke; Williams, Bryan M.; Zheng, Yalin; Shen, Yao-Chun

    2017-06-01

    The multiple layer paint systems on modern cars serve two end purposes, they firstly protect against corrosion and secondly give the desired visual appearance. To ensure consistent corrosion protection and appearance, suitable Quality Assurance (QA) measures on the final product are required. Various (layer thickness and consistency, layer composition, flake statistics, surface profile and layer dryness) parameters are of importance, each with specific techniques that can measure one or some of them but no technique that can measure all or most of them. Optical Coherence Tomography (OCT) is a 3D imaging technique with micrometre resolution. Since 2016, OCT measurements of layer thickness and consistency, layer composition fingerprint and flake statistics have been reported. In this paper we demonstrate two more novel applications of OCT to automotive paints. Firstly, we use OCT to quantify unwanted surface texture, which leads to an "orange peel" visual defect. This was done by measuring the surface profiles of automotive paints, with an unoptimised precision of 37 nm over lateral range of 7 mm, to quantify texture of less than 500 nm. Secondly, we demonstrate that OCT can measure how dry a coating layer is by measuring how fast it is still shrinking quasiinstantaneously, using Fourier phase sensitivity.

  1. EB application in pressure sensitive adhesives

    International Nuclear Information System (INIS)

    Hisashi Itoh; Ichiro Enomoto

    1999-01-01

    Two kinds of pressure sensitive adhesives (PSA's), that were formulations of radiation cross-linkable styrene-isoprene block copolymer (SIS) and complete hydrogenated aliphatic tackifying resin or non-hydrogenated, were prepared and the electron beam (EB) irradiation effect on these PSA performances such as peel strength against some kinds of adherends was studied. The results from measuring of PSA performance exhibit the close correlation between EB irradiation effect of these and the miscibility of the tackifying resin against SIS. Further it was clarified that PSA performance was influenced by the surface tension of adherends

  2. Order-fractal transitions in abstract paintings

    Energy Technology Data Exchange (ETDEWEB)

    Calleja, E.M. de la, E-mail: elsama79@gmail.com [Instituto de Física, Universidade Federal do Rio Grande do Sul, Caixa Postal 15051, 91501-970, Porto Alegre, RS (Brazil); Cervantes, F. [Department of Applied Physics, CINVESTAV-IPN, Carr. Antigua a Progreso km.6, Cordemex, C.P.97310, Mérida, Yucatán (Mexico); Calleja, J. de la [Department of Informatics, Universidad Politécnica de Puebla, 72640 (Mexico)

    2016-08-15

    In this study, we determined the degree of order for 22 Jackson Pollock paintings using the Hausdorff–Besicovitch fractal dimension. Based on the maximum value of each multi-fractal spectrum, the artworks were classified according to the year in which they were painted. It has been reported that Pollock’s paintings are fractal and that this feature was more evident in his later works. However, our results show that the fractal dimension of these paintings ranges among values close to two. We characterize this behavior as a fractal-order transition. Based on the study of disorder-order transition in physical systems, we interpreted the fractal-order transition via the dark paint strokes in Pollock’s paintings as structured lines that follow a power law measured by the fractal dimension. We determined self-similarity in specific paintings, thereby demonstrating an important dependence on the scale of observations. We also characterized the fractal spectrum for the painting entitled Teri’s Find. We obtained similar spectra for Teri’s Find and Number 5, thereby suggesting that the fractal dimension cannot be rejected completely as a quantitative parameter for authenticating these artworks. -- Highlights: •We determined the degree of order in Jackson Pollock paintings using the Hausdorff–Besicovitch dimension. •We detected a fractal-order transition from Pollock’s paintings between 1947 and 1951. •We suggest that Jackson Pollock could have painted Teri’s Find.

  3. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  4. A highly sensitive pressure sensor using a Au-patterned polydimethylsiloxane membrane for biosensing applications

    International Nuclear Information System (INIS)

    Liu, Xinchuan; Zhu, Yihao; Nomani, Md W; Koley, Goutam; Wen, Xuejun; Hsia, Tain-Yen

    2013-01-01

    We report on the fabrication and characterization of a highly sensitive pressure sensor using a Au film patterned on a polydimethylsiloxane (PDMS) membrane. The strain-induced change in the film resistance was utilized to perform the quantitative measurement of absolute pressure. The highest sensitivity obtained for a 200 µm thick PDMS film sensor was 0.23/KPa with a range of 50 mm Hg, which is the best result reported so far, over that range, for any pressure sensor on a flexible membrane. The noise-limited pressure resolution was found to be 0.9 Pa (0.007 mm Hg), and a response time of ∼200 ms, are the best reported results for these sensors. The ultrahigh sensitivity is attributed to the strain-induced formation of microcracks, the effect of which on the resistance change was found to be highly reversible within a certain pressure range. A physical model correlating the sensitivity with the sensor parameters and crack geometry has been proposed. (paper)

  5. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  6. Visualization of pigment distributions in paintings using synchrotron K-edge imaging

    International Nuclear Information System (INIS)

    Krug, K.; Dik, J.; Leeuw, M.; Whitson, A. den; Tortora, J.; Coan, P.; Nemoz, C.; Bravin, A.

    2006-01-01

    X-ray radiography plays an important role in the study of artworks and archaeological artifacts. The internal structure of objects provides information on genesis, authenticity, painting technique, material condition and conservation history. Transmission radiography, however, does not provide information on the exact elemental composition of objects and heavy metal layers can shadow or obscure the ones including lighter elements. This paper presents the first application of synchrotron-based K-edge absorption imaging applied to paintings. Using highly monochromatic radiation, K-edge imaging is used to obtain elemental distribution images over large areas. Such elemental maps visualize the distribution of an individual pigment throughout the paint stratigraphy. This provides color information on hidden paint layers, which is of great relevance to art historians and painting conservators. The main advantage is the quick data acquisition time and the sensitivity to elements throughout the entire paint stratigraphy. The examination of a test painting is shown and further instrumental developments are discussed. (orig.)

  7. Preference for and discrimination of paintings by mice.

    Directory of Open Access Journals (Sweden)

    Shigeru Watanabe

    Full Text Available I measured preference for paintings (Renoir vs. Picasso or Kandinsky vs. Mondrian in mice. In general mice did not display a painting preference except for two mice: one preferred Renoir to Picasso, and the other preferred Kandinsky to Mondrian. Thereafter, I examined discrimination of paintings with new mice. When exposure to paintings of one artist was associated with an injection of morphine (3.0 mg/kg, mice displayed conditioned preference for those paintings, showing discrimination of paintings by Renoir from those by Picasso, and paintings by Kandinsky from those by Mondrian after the conditioning. They also exhibited generalization of the preference to novel paintings of the artists. After conditioning with morphine for a set of paintings consisting of two artists, mice showed discrimination between two sets of paintings also from the two artists but not in association with morphine. These results suggest that mice can discriminate not only between an artist's style but also among paintings of the same artist. When mice were trained to discriminate a pair of paintings by Kandinsky and Renoir in an operant chamber equipped with a touch screen, they showed transfer of the discrimination to new pairs of the artists, but did not show transfer of discrimination of paintings by other artists, suggesting generalization.

  8. Effect of oxygen pressure on sensitivity of CR-39 used for astronauts radiation dosimetry

    International Nuclear Information System (INIS)

    Murai, T.; Yabe, S.; Nagamatsu, A.; Tawara, H.; Kumagai, H.; Miyazawa, Y.; Kitajo, K.; Kodaira, S.; Yasuda, N.

    2006-01-01

    The personal radiation dosimeters for astronauts are exposed to low-pressure oxygen gas (0.29 atmospheres) during extra-vehicle activities. CR-39 plastic track detectors are one of the typical passive dosimeters for space radiation monitoring. We investigated change in track formation sensitivity of the antioxidant-doped CR-39 plastic with which oxygen gas comes in contact at different pressures up to 2 atmospheres for 1h to 10 days. The oxygen effect on sensitivity was measured for the C, Si and Fe ions (10-200 keV/μm) from the HIMAC heavy ion accelerator. The sensitivity is obviously sensitive to oxygen pressure at heavy-ion exposures, but not sensitive to the experience of oxygen atmosphere before and after the ion exposures. The maximum sensitivity is obtained at 0.29 atmospheres. The present experimental data suggested that the effect depends on LET of incident particles. (author)

  9. MP.EXE Microphone pressure sensitivity calibration calculation program

    DEFF Research Database (Denmark)

    Rasmussen, Knud

    1999-01-01

    MP.EXE is a program which calculates the pressure sensitivity of LS1 microphones as defined in IEC 61094-1, based on measurement results performed as laid down in IEC 61094-2.A very early program was developed and written by K. Rasmussen. The code of the present heavily extended version is writte...... by E.S. Olsen.The present manual is written by K.Rasmussen and E.S. Olsen....

  10. A gas thermometer for vapor pressure measurements

    Science.gov (United States)

    Rusin, A. D.

    2008-08-01

    The pressure of an inert gas over the range 400 1000 K was measured on a tensimetric unit with a quartz membrane pressure gauge of enhanced sensitivity. It was shown that a reactor with a membrane null gauge could be used as a gas thermometer. The experimental confidence pressure and temperature intervals were 0.07 torr and 0.1 K at a significance level of 0.05. A Pt-Pt/10% Rh thermocouple was calibrated; the results were approximated by a polynomial of degree five. The error in temperature calculations was 0.25 K.

  11. Allergic contact dermatitis from resin hardeners during the manufacture of thermosetting coating paints.

    Science.gov (United States)

    Foulds, I S; Koh, D

    1992-02-01

    5 production operators from 2 factories manufacturing thermosetting coating paint developed work-related skin disorders within 12 months of the introduction of a new powdered paint product. All 5 workers were found to have allergic contact dermatitis from 2 epoxy resin hardeners, both of which were commercial preparations of triglycidyl isocyanurate (TGIC). 2 of the workers had concomitant sensitization to epoxy resin in the standard series and several of the epoxy resin preparations at the workplace. TGIC has been reported as a contact sensitizer both in persons producing the chemical and among end-users of TGIC-containing products. These 5 reported cases document allergic contact dermatitis from commercial TGIC among exposed workers during an intermediate process of powdered paint manufacture. The possibility of substituting this epoxy resin hardener with less sensitizing alternatives should be explored.

  12. Zero-birefringence pressure-sensitive adhesives

    Directory of Open Access Journals (Sweden)

    Hiroto Ito

    2012-06-01

    Full Text Available We have developed zero-birefringence pressure-sensitive adhesives (PSAs that exhibit almost no birefringence at any orientation of polymer chains. To evaluate the birefringence of PSAs quantitatively, we report a novel birefringence-measurement method utilizing zero–zero-birefringence polymers that exhibit no birefringence at any orientation of polymer chains and in elastic deformation. By employing this method, we designed and synthesized poly(butyl acrylate/phenoxyethyl acrylate/acrylic acid/hydroxyethyl acrylate = 80.0:20.0:1.5:1.0 (by weight that contains 1.8 wt% isocyanate-type crosslinker that exhibited almost zero birefringence. Furthermore, we demonstrated that after the accelerated aging test by applying heat, this zero-birefringence PSA almost completely prevented light leakage through crossed polarizers.

  13. Plane-stress fields for sharp notches in pressure-sensitive materials

    International Nuclear Information System (INIS)

    Al-Abduljabbar, Abdulhamid

    2003-01-01

    The effect of pressure sensitive yield on materials toughness can be determined by investigating stress fields around cracks and notches. In this work, fully-developed plastic stress fields around sharp wedge-shaped notches of perfectly-plastic pressure-sensitive materials are investigated for plane-stress case and Mode 1 loading condition. The pressure-sensitive yielding behavior is represented using the Drucker-Prager criterion. Using equilibrium equations, boundary conditions, and the yield criterion, closed-form expressions for stress fields are derived. The analysis covers the gradual change in the notch angle and compares it with the limiting case of a pure horizontal crack. Effects of notch geometry and pressure sensitivity on stress fields are examined by considering different specimen geometries, as well as different levels of pressure sensitivity. Results indicate that while the stress values directly ahead of the notch-tip are not affected, the extent of stress sector at notch front is reduced, thereby causing increase in the radial stress value around the notch. As the pressure sensitivity increases the reduction of the stress sector directly ahead of the notch tip is more evident. Also, for high pressure sensitivity values, introduction of the notch angle reduces the variation of the stress levels. Results are useful for design of structural components. (author)

  14. Allergic contact dermatitis from 2-n-octyl-4-isothiazolin-3-one, a paint mildewcide

    DEFF Research Database (Denmark)

    Mathias, C G; Andersen, Klaus Ejner; Hamann, K

    1983-01-01

    Severe allergic contact dermatitis from a paint mildewcide, 2-n-octyl-4-isothiazolin-3-one, developed in a worker formulating latex paints within a paint manufacturing company, Guinea pig maximization testing demonstrated this to be a moderate sensitizer. Further cases of allergic contact...... dermatitis may be encountered as the use of this biocide increases in the market place....

  15. Flexible, highly sensitive pressure sensor with a wide range based on graphene-silk network structure

    Science.gov (United States)

    Liu, Ying; Tao, Lu-Qi; Wang, Dan-Yang; Zhang, Tian-Yu; Yang, Yi; Ren, Tian-Ling

    2017-03-01

    In this paper, a flexible, simple-preparation, and low-cost graphene-silk pressure sensor based on soft silk substrate through thermal reduction was demonstrated. Taking silk as the support body, the device had formed a three-dimensional structure with ordered multi-layer structure. Through a simple and low-cost process technology, graphene-silk pressure sensor can achieve the sensitivity value of 0.4 kPa - 1 , and the measurement range can be as high as 140 kPa. Besides, pressure sensor can have a good combination with knitted clothing and textile product. The signal had good reproducibility in response to different pressures. Furthermore, graphene-silk pressure sensor can not only detect pressure higher than 100 kPa, but also can measure weak body signals. The characteristics of high-sensitivity, good repeatability, flexibility, and comfort for skin provide the high possibility to fit on various wearable electronics.

  16. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  17. Large-scale quantitative analysis of painting arts.

    Science.gov (United States)

    Kim, Daniel; Son, Seung-Woo; Jeong, Hawoong

    2014-12-11

    Scientists have made efforts to understand the beauty of painting art in their own languages. As digital image acquisition of painting arts has made rapid progress, researchers have come to a point where it is possible to perform statistical analysis of a large-scale database of artistic paints to make a bridge between art and science. Using digital image processing techniques, we investigate three quantitative measures of images - the usage of individual colors, the variety of colors, and the roughness of the brightness. We found a difference in color usage between classical paintings and photographs, and a significantly low color variety of the medieval period. Interestingly, moreover, the increment of roughness exponent as painting techniques such as chiaroscuro and sfumato have advanced is consistent with historical circumstances.

  18. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  19. TeraHertz imaging of hidden paint layers on canvas

    NARCIS (Netherlands)

    Adam, A.J.L.; Planken, P.C.M.; Meloni, S.; Dik, J.

    2009-01-01

    We show terahertz reflection images of hidden paint layers in a painting on canvas and compare the results with X-ray Radiography and Infrared Reflectography. Our terahertz measurements show strong reflections from both the canvas/paint interface and from the raw umber/lead white interface,

  20. Lead content in household paints in India

    International Nuclear Information System (INIS)

    Kumar, Abhay; Gottesfeld, Perry

    2008-01-01

    Lead and its compounds are used in paints not only to impart colour but also to make it durable, corrosion resistant and to improve drying. Adverse health impacts of lead especially on children have led countries to restrict or ban its use in paints. While U.S. and other developed countries instituted measures to limit the use of lead in paints, some developing countries including India have failed to regulate their lead content. The present study was undertaken to determine the levels of lead in new latex (water-based) and enamel paints (oil-based) intended for residential use in India. A total of 69 paint samples (38 latex and 31 enamel samples) from six of the most popular brands were analysed for lead concentrations. While all latex paint samples contained low levels of lead, (i.e., well below 600 ppm as regulated by United States' Consumer Products Safety Commission) the enamel paint samples of all but one brand contained significant concentrations of lead, ranging up to 140,000 ppm. In fact 84% of the enamel paints tested exceeded 600 ppm whereas only 38 % of all samples (including latex and enamel types) exceeded this regulatory level

  1. Characterization of abrasion-induced nanoparticle release from paints into liquids and air

    Science.gov (United States)

    Golanski, L.; Gaborieau, A.; Guiot, A.; Uzu, G.; Chatenet, J.; Tardif, F.

    2011-07-01

    Two standard methods for the characterization of the abrasion nanoparticle release into air and liquid from coatings containing nanoparticles were developed. Details of the abrasion processes and the measurement methods are shown. Paints were formulated in an industrial facility. Standard abrasion conditions in wet environments were simulated. The size distribution of the particles abraded into liquid was analyzed by a laser granulometer: submicrometric and micrometric particles were observed, but no nanometric particles. The nanoparticles released in liquid were deposited on filters for SEM (Scanning Electron Microscopy) analysis. No free or agglomerated nanoparticles were observed by SEM: nanoparticles seem to remain embedded in the paint matrix. The same coatings were abraded in the air using another standard method. The ELPI (Electrical Low Pressure Impactor) was used to determine the number size distribution of the dust generated. Abrasion is found to produce submicrometric and micrometric particles in the air but no nanoparticles. Further characterizations by SEM confirmed that no free or agglomerated nanoparticles were emitted: nanoparticles seem to remain embedded in the paint matrix.

  2. Characterization of abrasion-induced nanoparticle release from paints into liquids and air

    International Nuclear Information System (INIS)

    Golanski, L; Guiot, A; Uzu, G; Tardif, F; Gaborieau, A; Chatenet, J

    2011-01-01

    Two standard methods for the characterization of the abrasion nanoparticle release into air and liquid from coatings containing nanoparticles were developed. Details of the abrasion processes and the measurement methods are shown. Paints were formulated in an industrial facility. Standard abrasion conditions in wet environments were simulated. The size distribution of the particles abraded into liquid was analyzed by a laser granulometer: submicrometric and micrometric particles were observed, but no nanometric particles. The nanoparticles released in liquid were deposited on filters for SEM (Scanning Electron Microscopy) analysis. No free or agglomerated nanoparticles were observed by SEM: nanoparticles seem to remain embedded in the paint matrix. The same coatings were abraded in the air using another standard method. The ELPI (Electrical Low Pressure Impactor) was used to determine the number size distribution of the dust generated. Abrasion is found to produce submicrometric and micrometric particles in the air but no nanoparticles. Further characterizations by SEM confirmed that no free or agglomerated nanoparticles were emitted: nanoparticles seem to remain embedded in the paint matrix.

  3. Pico gauges for minimally invasive intracellular hydrostatic pressure measurements

    DEFF Research Database (Denmark)

    Knoblauch, Jan; Mullendore, Daniel L.; Jensen, Kaare Hartvig

    2014-01-01

    Intracellular pressure has a multitude of functions in cells surrounded by a cell wall or similar matrix in all kingdoms of life. The functions include cell growth, nastic movements, and penetration of tissue by parasites. The precise measurement of intracellular pressure in the majority of cells......, however, remains difficult or impossible due to their small size and/or sensitivity to manipulation. Here, we report on a method that allows precise measurements in basically any cell type over all ranges of pressure. It is based on the compression of nanoliter and picoliter volumes of oil entrapped...... in the tip of microcapillaries, which we call pico gauges. The production of pico gauges can be accomplished with standard laboratory equipment, and measurements are comparably easy to conduct. Example pressure measurements are performed on cells that are difficult or impossible to measure with other methods....

  4. Chemical, morphological and chromatic behavior of mural paintings under Er:YAG laser irradiation

    Science.gov (United States)

    Striova, J.; Camaiti, M.; Castellucci, E. M.; Sansonetti, A.

    2011-08-01

    Several pigments (malachite CuCO3ṡCu(OH)2, azurite 2CuCO3ṡCu(OH)2, yellow ochre (goethite α-FeOOH, gypsum CaSO4ṡ2H2O), St. John's white CaCO3 formed from slaked lime) and respective mural paintings specimens were subjected to the free-running Er:YAG laser radiation in order to study their damage thresholds, in a broad range of laser fluences, both in dry and wet conditions. The specimens' damage thresholds were evaluated by spectroscopic methods, colorimetric measurements and microscopic observation. The pigments containing -OH groups were found to be more sensitive than St. John's white; hence the most sensitive paint layers in dry conditions are those containing malachite, azurite (both 1.3 J/cm2) and yellow ochre (2.5 J/cm2) as compared to the ones containing St. John's white (15.2 J/cm2). The presence of wetting agents (w.a.) attenuated the pigments chemical alteration. The damage thresholds of all the paint layers, in presence of w.a., were found to be around 2.5 J/cm2. The alteration was caused by thermo-mechanical damage and by binding medium ablation of a fresco and a secco prepared specimens, respectively.

  5. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a) When..., paint-related material, adhesives, ink and resins must be packaged as follows: (1) As prescribed in...

  6. Differences in reactions to paintings by male and female college students.

    Science.gov (United States)

    Polzella, D J

    2000-08-01

    38 male and 55 female college students rated digitized color facsimiles of 40 paintings that varied in artistic period (Renaissance, Rococo, Impressionist, Post-Impressionist, 20th Century) and subject matter (portrait, landscape, still life, behavior depiction) on 12 7-point semantic differential scales, e.g., simple-complex. Women judged the content of Rococo and Impressionist paintings as more pleasing than did men and Impressionist paintings evoked greater feelings of pleasure and relaxation among women than among men. In addition, paintings that depicted behaviors evoked more pleasure and alertness among women than among men. The results were interpreted in terms of underlying differences between men and women in perceptual style and emotional sensitivity.

  7. Spectrally selective paint coatings. Preparation and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Crnjak Orel, Z.C.; Klanjsek Gunde, M. [National Institute of Chemistry, Hajdrihova 19, SI-1000 Ljubljana (Slovenia)

    2001-06-01

    Preparation and characterization of spectrally selective paint coating for photothermal solar energy conversion are discussed. The applied methods for preparation of paints with described measurements and calculations of black-pigmented coatings were reviewed. The article represents not only possible future applications but also past and current applications of spectrally selective paint coating which are used all over the world since the 1980s. Spectrally selective paint coatings based on combinations of two types of resins, various types of pigments and three types of silica, were prepared. The influence of pigment type and pigment volume concentration (PVC) was studied by applying the Kubelka-Munk (K-M) theory. The relation between the degrees of dispersion and distribution of pigment particles across the paint layer is discussed in terms of K-M coefficients.

  8. A Flexible and Highly Sensitive Piezoresistive Pressure Sensor Based on Micropatterned Films Coated with Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Jia-lin Yao

    2016-01-01

    Full Text Available Excellent flexibility, high sensitivity, and low consumption are essential characteristics in flexible microtube pressure sensing occasion, for example, implantable medical devices, industrial pipeline, and microfluidic chip. This paper reports a flexible, highly sensitive, and ultrathin piezoresistive pressure sensor for fluid pressure sensing, whose sensing element is micropatterned films with conductive carbon nanotube layer. The flexible pressure sensor, the thickness of which is 40 ± 10 μm, could be economically fabricated by using biocompatible polydimethylsiloxane (PDMS. Experimental results show that the flexible pressure sensor has high sensitivity (0.047 kPa−1 in gas sensing and 5.6 × 10−3 kPa−1 in liquid sensing and low consumption (<180 μW, and the sensor could be used to measure the pressure in curved microtubes.

  9. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    Science.gov (United States)

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  10. Surface pressure retrieval from SCIAMACHY measurements in the O2 A Band: validation of the measurements and sensitivity on aerosols

    Directory of Open Access Journals (Sweden)

    B. van Diedenhoven

    2005-01-01

    Full Text Available We perform surface pressure retrievals from cloud-free Oxygen A band measurements of SCIAMACHY. These retrievals can be well validated because surface pressure is a quantity that is, in general, accurately known from meteorological models. Therefore, surface pressure retrievals and their validation provide important insight into the quality of the instrument calibration. Furthermore, they can provide insight into retrievals which are affected by similar radiation transport processes, for example the retrieval of total columns of H2O, CO, CO2 and CH4. In our retrieval aerosols are neglected. Using synthetic measurements, it is shown that for low to moderate surface albedos this leads to an underestimation of the retrieved surface pressures. For high surface albedos this generally leads to an overestimation of the retrieved surface pressures. The surface pressures retrieved from the SCIAMACHY measurements indeed show this dependence on surface albedo, when compared to the corresponding pressures from a meteorological database. However, an offset of about 20 hPa was found, which can not be caused by neglecting aerosols in the retrieval. The same offset was found when comparing the retrieved surface pressures to those retrieved from co-located GOME Oxygen A band measurements. This implies a calibration error in the SCIAMACHY measurements. By adding an offset of 0.86% of the continuum reflectance at 756 nm to the SCIAMACHY reflectance measurements, this systematic bias vanishes.

  11. Sensitivity of Pressure Sensors Enhanced by Doping Silver Nanowires

    Directory of Open Access Journals (Sweden)

    Baozhang Li

    2014-06-01

    Full Text Available We have developed a highly sensitive flexible pressure sensor based on a piezopolymer and silver nanowires (AgNWs composite. The composite nanofiber webs are made by electrospinning mixed solutions of poly(inylidene fluoride (PVDF and Ag NWs in a cosolvent mixture of dimethyl formamide and acetone. The diameter of the fibers ranges from 200 nm to 500 nm, as demonstrated by SEM images. FTIR and XRD results reveal that doping Ag NWs into PVDF greatly enhances the content of β phase in PVDF. This β phase increase can be attributed to interactions between the Ag NWs and the PVDF matrix, which forces the polymer chains to be embedded into the β phase crystalline. The sensitivity of the pressure sensors agrees well with the FTIR and XRD characteristics. In our experiments, the measured sensitivity reached up to 30 pC/N for the nanofiber webs containing 1.5 wt% Ag NWs, which is close to that of poly(vinylidene fluoride-trifluoroethylene [P(VDF-TrFE, (77/23]. This study may provide a new method of fabricating high performance flexible sensors at relatively low cost compared with sensors based on [P(VDF-TrFE, (77/23].

  12. A Newly Designed Fiber-Optic Based Earth Pressure Transducer with Adjustable Measurement Range

    Directory of Open Access Journals (Sweden)

    Hou-Zhen Wei

    2018-03-01

    Full Text Available A novel fiber-optic based earth pressure sensor (FPS with an adjustable measurement range and high sensitivity is developed to measure earth pressures for civil infrastructures. The new FPS combines a cantilever beam with fiber Bragg grating (FBG sensors and a flexible membrane. Compared with a traditional pressure transducer with a dual diaphragm design, the proposed FPS has a larger measurement range and shows high accuracy. The working principles, parameter design, fabrication methods, and laboratory calibration tests are explained in this paper. A theoretical solution is derived to obtain the relationship between the applied pressure and strain of the FBG sensors. In addition, a finite element model is established to analyze the mechanical behavior of the membrane and the cantilever beam and thereby obtain optimal parameters. The cantilever beam is 40 mm long, 15 mm wide, and 1 mm thick. The whole FPS has a diameter of 100 mm and a thickness of 30 mm. The sensitivity of the FPS is 0.104 kPa/με. In addition, automatic temperature compensation can be achieved. The FPS’s sensitivity, physical properties, and response to applied pressure are extensively examined through modeling and experiments. The results show that the proposed FPS has numerous potential applications in soil pressure measurement.

  13. Increased persistence of antifouling paint biocides when associated with paint particles

    International Nuclear Information System (INIS)

    Thomas, K.V.; McHugh, M.; Hilton, M.; Waldock, M.

    2003-01-01

    Release of biocides associated with paint particles into marinas may increase their persistence in the environment. - Current regulatory risk assessment procedures only assess the impact of antifouling paint biocides that are released through leaching from a painted surface. Hull cleaning activities can lead to particles of antifouling paint containing biocides to enter the environment. Comparative pseudo-first order anaerobic degradation rate constants and half-lives were determined for a selection of common antifouling paint booster biocides, their degradation products, and associated with paint particles. Anaerobic half-lives of <0.5 days were calculated for chlorothalonil, dichlofluanid, and SeaNine 211, between 1 and 3 days for DCPMU and DCPU, between 14 and 35 days for diuron and CPDU, and over 226 days for GS26575 and Irgarol 1051. Increased persistence was observed when the compounds were introduced to sediments associated with antifouling paint particles. When present as antifouling paint particles, an increased half-life of 9.9 days for SeaNine 211 and 1.4 days was calculated for dichlofluanid, no significant degradation was observed for diuron. It is suspected that this is due to much of the biocide being initially bound within the matrix of the paint particle that is slowly released through dissolution processes into the sediment pore water prior to degradation. The release of booster biocides associated with paint particles into marinas has the potential to lead to their accumulation unless activities such as hull cleaning are strictly regulated

  14. Increased persistence of antifouling paint biocides when associated with paint particles

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, K.V.; McHugh, M.; Hilton, M.; Waldock, M

    2003-05-01

    Release of biocides associated with paint particles into marinas may increase their persistence in the environment. - Current regulatory risk assessment procedures only assess the impact of antifouling paint biocides that are released through leaching from a painted surface. Hull cleaning activities can lead to particles of antifouling paint containing biocides to enter the environment. Comparative pseudo-first order anaerobic degradation rate constants and half-lives were determined for a selection of common antifouling paint booster biocides, their degradation products, and associated with paint particles. Anaerobic half-lives of <0.5 days were calculated for chlorothalonil, dichlofluanid, and SeaNine 211, between 1 and 3 days for DCPMU and DCPU, between 14 and 35 days for diuron and CPDU, and over 226 days for GS26575 and Irgarol 1051. Increased persistence was observed when the compounds were introduced to sediments associated with antifouling paint particles. When present as antifouling paint particles, an increased half-life of 9.9 days for SeaNine 211 and 1.4 days was calculated for dichlofluanid, no significant degradation was observed for diuron. It is suspected that this is due to much of the biocide being initially bound within the matrix of the paint particle that is slowly released through dissolution processes into the sediment pore water prior to degradation. The release of booster biocides associated with paint particles into marinas has the potential to lead to their accumulation unless activities such as hull cleaning are strictly regulated.

  15. Enhanced sodium sensitivity and disturbed circadian rhythm of blood pressure in essential hypertension.

    Science.gov (United States)

    Uzu, Takashi; Kimura, Genjiro; Yamauchi, Atsushi; Kanasaki, Masami; Isshiki, Keiji; Araki, Shin-ichi; Sugiomoto, Toshiro; Nishio, Yoshihiko; Maegawa, Hiroshi; Koya, Daisuke; Haneda, Masakazu; Kashiwagi, Atsunori

    2006-08-01

    To assess whether an association between sodium-sensitive hypertension and metabolic syndrome exists; and whether, in patients with metabolic syndrome, the nocturnal fall of blood pressure decreases and salt restriction affects the circadian blood pressure rhythm. Japanese patients with essential hypertension, who were treated without any antihypertensive agent, were maintained on a high-sodium diet and a low-sodium diet for 1 week each. On the last day of each diet, the 24-h blood pressures were measured. A diagnosis of metabolic syndrome was made according to the International Diabetes Foundation definition Among the 56 patients with essential hypertension, 15 patients were complicated with metabolic syndrome while 41 patients were not. The nocturnal blood pressure fall was significant in patients without metabolic syndrome, while it was not so in patients with metabolic syndrome. Only in patients with metabolic syndrome was the nocturnal blood pressure fall enhanced by sodium restriction. The prevalence of sodium-sensitive hypertension in patients with metabolic syndrome was significantly higher than in those without metabolic syndrome (70.6 versus 36.0%, respectively; P = 0.017). A multiple logistic regression analysis revealed central obesity to be an independent risk factor for sodium-sensitive hypertension (odds ratio, 1.41; 95% confidence interval, 1.04-1.91). In patients with essential hypertension, an inter-relationship exists among metabolic syndrome, enhanced sodium sensitivity of the blood pressure and non-dipping. The elevated risk of cardiovascular diseases in patients with metabolic syndrome may be related to sodium-sensitive hypertension and non-dipping.

  16. [Annual blood pressure dynamics and weather sensitivity in women].

    Science.gov (United States)

    Varlamova, N G; Zenchenko, T A; Boyko, E R

    To study the annual cycle of blood pressure (BP) and weather sensitivity in normotensive women aged 20-59 years. The same group of 25 non-smoking women who had been living in the European North of Russia (62° N, 51° E) almost since their birth and were engaged in moderate-intensity mental labor was daily examined. During a year, there were 11823 blood pressure measurements using the Korotkoff technique; heart rate was calculated by palpation. These meteorological parameters were taken at the websites: http://meteo.infospace.ru and ftp://ftp.ngdc.noaa.gov/stp/geomagnetic_data/indices/kp_ap. The statistical significance of differences in the indicators was determined using the Fisher's test and the Newman-Keuls test. The study used a correlation analysis with the calculation of the Spearman's rank correlation coefficient. The maximum systolic and diastolic BP values were revealed in February and January, respectively. The minimum values of systolic BP were detected in July; those of diastolic BP were in August. An individual-based analysis of sensitivity to environmental variations showed that about 88% of the women responded to atmospheric temperature; nearly 44% did to geomagnetic activity; almost 24% were sensitive to relative air humidity, and about 16% of the women were to atmospheric pressure. The dynamics of systolic and diastolic BP in the annual cycle of women depends on meteorological factors and suggests that there is a change in the priorities of its control in different periods of a year.

  17. Painting

    DEFF Research Database (Denmark)

    Petersen, Anne Ring

    2012-01-01

    and discursive battles over the essentially self-reflective question of “What is painting?” Over the last decades it has also become an intermedial laboratory in which artists experiment with developing a connective aesthetic in the interface between painting and other media. Accordingly, it is has become...

  18. Analysis of fresco paintings by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Musilek, L.; Kopecka, I.

    2000-01-01

    In this work we present the application of X-ray fluorescence analysis (XRFA) to examine fresco paintings from the Karlstejn castle. The X-ray fluorescence apparatus built and operated in the Laboratory of Quantitative Methods in Research of Ancient Monuments was used for the purpose of fresco paintings measurements. The X-ray sources (radionuclides) generate the characteristic X-ray photons from the sample. The Si(Li) detector measures numbers and energies of photons emitted from the specimen. The energy and number of photons detected can be converted into kind and amount of measured atoms. These results give data for qualitative and quantitative analysis of samples. XRFA is relatively simple and non-destructive method. Capability of in-situ measurement is one of big advantages of this method. The radionuclide sources of exciting radiation (e.g. 55 Fe enables the excitation of elements with Z up to 23, 238 Pu is used in interval of Z from 20 to 39 etc.) were used. An Si(Li) semiconductor detector with a 5 l Dewar vessel and portable spectroscopy system enable the in situ measurement. Narrow collimation of the exciting beam makes it possible to select the measured area of fresco painting. The valuable fresco paintings from the Karlstejn castle were investigated in this way. The measurements were carried out in collaboration with the Analytical Laboratory of the State Institute for the Preservation of Historic Monuments. A suitable analysis of paintings makes it possible to detect the kind of colours and evaluate changes in the surface colour of paintings and suggest useful and timely procedures for their conservation and restoration. (author)

  19. Flexible Ferroelectric Sensors with Ultrahigh Pressure Sensitivity and Linear Response over Exceptionally Broad Pressure Range.

    Science.gov (United States)

    Lee, Youngoh; Park, Jonghwa; Cho, Soowon; Shin, Young-Eun; Lee, Hochan; Kim, Jinyoung; Myoung, Jinyoung; Cho, Seungse; Kang, Saewon; Baig, Chunggi; Ko, Hyunhyub

    2018-04-24

    Flexible pressure sensors with a high sensitivity over a broad linear range can simplify wearable sensing systems without additional signal processing for the linear output, enabling device miniaturization and low power consumption. Here, we demonstrate a flexible ferroelectric sensor with ultrahigh pressure sensitivity and linear response over an exceptionally broad pressure range based on the material and structural design of ferroelectric composites with a multilayer interlocked microdome geometry. Due to the stress concentration between interlocked microdome arrays and increased contact area in the multilayer design, the flexible ferroelectric sensors could perceive static/dynamic pressure with high sensitivity (47.7 kPa -1 , 1.3 Pa minimum detection). In addition, efficient stress distribution between stacked multilayers enables linear sensing over exceptionally broad pressure range (0.0013-353 kPa) with fast response time (20 ms) and high reliability over 5000 repetitive cycles even at an extremely high pressure of 272 kPa. Our sensor can be used to monitor diverse stimuli from a low to a high pressure range including weak gas flow, acoustic sound, wrist pulse pressure, respiration, and foot pressure with a single device.

  20. MHD pressure drop of imperfect insulation of liquid metal flow

    International Nuclear Information System (INIS)

    Horiike, H.; Nishiura, R.; Inoue, S.; Miyazaki, K.

    2000-01-01

    An experiment was performed to study magnetohydrodynamic (MHD) pressure gradient in the case of an imperfect electric insulation coating when using NaK loop. Test channels with uniform defects in their coating were made by painting inner surface with acrylic lacquer insulation. It was found that the exponent to B -- which is 1 for insulated walls, and 2 for conducting ones, was very sensitive to crack fractions lower than 25%. The pressure gradient was found to increase almost linearly with the fraction

  1. Study on application methods of three adhesives used in the consolidation of contemporary paintings

    Directory of Open Access Journals (Sweden)

    Rosario Llamas

    2011-01-01

    Full Text Available Consolidation of contemporary paintings is a practice as complicated as delicate mainly due to the possibility of modifying the works' finishing. Conservators sometimes find limits facing these troubles because of the difficulty of applying adhesives with a paintbrush. The authors, in their attempt to give a practical and useful solution to this problem, have experimented in this work with different adhesives which are adequate for consolidation of contemporary paintings. They also have evaluated different application methods, and all of these tests were developed on poorly-bounded paintings. The study on combined methods of application was undertaken in order to compare the use of an ultrasonic atomizer with a low-pressure micro-table and an ultrasonic atomizer without a low-pressure micro-table. In this occasion, the study just wanted to analyze the deviation of colorimetric and gloss parameters for detecting if surfaces suffer aesthetic variations which may interfere with the works' concept. Conclusions finally show that it is possible to heavily consolidate poorly-bounded paintings by using an aqueous adhesive in a low concentration and an ultrasonic atomizer. The combination with a low-pressure micro-table will depend on the necessity of a punctual or general action of the adhesive.

  2. The association between pressure pain sensitivity, and answers to questionnaires estimating psychological stress level in the workplace. A feasibility study

    DEFF Research Database (Denmark)

    Ballegaard, Søren; Petersen, Pernille; Gyntelberg, Finn

    2012-01-01

    To examine the association between pressure pain sensitivity (PPS) at the sternum as a measure of persistent stress assessed by questionnaires in a working population.......To examine the association between pressure pain sensitivity (PPS) at the sternum as a measure of persistent stress assessed by questionnaires in a working population....

  3. Measurements of skin friction in water using surface stress sensitive films

    International Nuclear Information System (INIS)

    Crafton, J W; Fonov, S D; Jones, E G; Goss, L P; Forlines, R A; Fontaine, A

    2008-01-01

    The measurement of skin friction on hydrodynamic surfaces is of significant value for the design of advanced naval technology, particularly at high Reynolds numbers. Here we report on the development of a new sensor for measurement of skin friction and pressure that operates in both air and water. This sensor is based on an elastic polymer film that deforms under the action of applied normal and tangential loads. Skin friction and pressure gradients are determined by monitoring these deformations and then solving an inverse problem using a finite element model of the elastic film. This technique is known as surface stress sensitive films. In this paper, we describe the development of a sensor package specifically designed for two-dimensional skin friction measurements at a single point. The package has been developed with the goal of making two-dimensional measurements of skin friction in water. Quantitative measurements of skin friction are performed on a high Reynolds number turbulent boundary layer in the 12 inch water tunnel at Penn State University. These skin friction measurements are verified by comparing them to measurements obtained with a drag plate as well as by performing two-dimensional velocity measurements above the sensor using a laser Doppler velocimetry system. The results indicate that the sensor skin friction measurements are accurate to better than 5% and repeatable to better than 2%. The directional sensitivity of the sensor is demonstrated by positioning the sensor at several orientations to the flow. A final interesting feature of this sensor is that it is sensitive to pressure gradients, not to static pressure changes. This feature should prove useful for monitoring the skin friction on a seafaring vessel as the operating depth is changed

  4. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  5. Electrochemical assessment of magnetite anti corrosive paints

    International Nuclear Information System (INIS)

    Escobar, D. M.; Arroyave, C.; Jaramillo, F.; Mattos, O. R.; Margarit, I. c.; Calderon, J.

    2003-01-01

    With the purpose of deepening in the understanding of the mechanisms of protection of anticorrosive pigments based on iron oxides, this work has been carried out on the production of pure magnetite, and copper and chromium doped magnetite, which were evaluated by different characterization techniques. The paints were prepared with a solvent less epoxy resin maintaining the Pigment volume Content near the Practical Critical value (CPVC), established for each pigment. The paints were applied on polished steel and monitored with electrochemical techniques at total immersion conditions. Permeability and impedance measurements of free films were also done. Impedance data were simulated with the Boukamp software. Results show that the paints pigmented with doped magnetite present better behaviour than a paint prepared with commercial hematite. (Author) 8 refs

  6. Does antifouling paint select for antibiotic resistance?

    Science.gov (United States)

    Flach, Carl-Fredrik; Pal, Chandan; Svensson, Carl Johan; Kristiansson, Erik; Östman, Marcus; Bengtsson-Palme, Johan; Tysklind, Mats; Larsson, D G Joakim

    2017-07-15

    There is concern that heavy metals and biocides contribute to the development of antibiotic resistance via co-selection. Most antifouling paints contain high amounts of such substances, which risks turning painted ship hulls into highly mobile refuges and breeding grounds for antibiotic-resistant bacteria. The objectives of this study were to start investigate if heavy-metal based antifouling paints can pose a risk for co-selection of antibiotic-resistant bacteria and, if so, identify the underlying genetic basis. Plastic panels with one side painted with copper and zinc-containing antifouling paint were submerged in a Swedish marina and biofilms from both sides of the panels were harvested after 2.5-4weeks. DNA was isolated from the biofilms and subjected to metagenomic sequencing. Biofilm bacteria were cultured on marine agar supplemented with tetracycline, gentamicin, copper sulfate or zinc sulfate. Biofilm communities from painted surfaces displayed lower taxonomic diversity and enrichment of Gammaproteobacteria. Bacteria from these communities showed increased resistance to both heavy metals and tetracycline but not to gentamicin. Significantly higher abundance of metal and biocide resistance genes was observed, whereas mobile antibiotic resistance genes were not enriched in these communities. In contrast, we found an enrichment of chromosomal RND efflux system genes, including such with documented ability to confer decreased susceptibility to both antibiotics and biocides/heavy metals. This was paralleled by increased abundances of integron-associated integrase and ISCR transposase genes. The results show that the heavy metal-based antifouling paint exerts a strong selection pressure on marine bacterial communities and can co-select for certain antibiotic-resistant bacteria, likely by favoring species and strains carrying genes that provide cross-resistance. Although this does not indicate an immediate risk for promotion of mobile antibiotic resistance, the

  7. The use of combined synchrotron radiation micro FT-IR and XRD for the characterization of Romanesque wall paintings

    International Nuclear Information System (INIS)

    Salvado, N.; Buti, S.; Pantos, E.; Bahrami, F.; Labrador, A.; Pradell, T.

    2008-01-01

    The high analytical sensitivity and high spatial resolution of synchrotron radiation-based techniques, in particular SR-XRD and SR-FT-IR, allows the identification of complex micrometric mixtures of compounds that constitute the different layers of ancient paintings. The reliability of the measurements even with an extremely small amount of sampled material is very high, and this is particularly important when analyzing art works. Furthermore, the micro size (10 x 10μm for FT-IR and 30 to 50 μm squared spot size for XRD) of the beam enables one to obtain detailed compositional profiles from the different chromatic and preparation layers. The sensitivity of the techniques is high enough for the determination of minor and trace compounds, such as reaction and weathering compounds. We report here the identification of pigments in the Romanesque wall paintings found in situ in the church of Saint Eulalia of Unha place in the Aran valley (central Pyrenees). During the first centuries of the second millennium numerous religious buildings were built in Western Europe in the Romanesque style. In particular, a great number of churches were built in the Pyrenees, most of which were decorated with wall paintings. Although only a few of these paintings have survived, they represent one of the most important collections of Romanesque art, both for their quantity and quality. A full identification of the pigments, binder, supports, and reaction and weathering compounds has been obtained. The results obtained, in particular aerinite as a pigment, indicate a clear connection between the paintings found in this Occitanian church and the Catalan Romanesque paintings from the south bound of the Pyrenees. (orig.)

  8. The use of combined synchrotron radiation micro FT-IR and XRD for the characterization of Romanesque wall paintings

    Energy Technology Data Exchange (ETDEWEB)

    Salvado, N.; Buti, S. [Universitat Politecnica de Catalunya, Dpt. d' Enginyeria Quimica, EPSEVG, Vilanova i la Geltru, Barcelona (Spain); Pantos, E.; Bahrami, F. [CCLRC, Daresbury Laboratory, Warrington (United Kingdom); Labrador, A. [LLS, BM16-ESRF, BP 220, Grenoble Cedex (France); Pradell, T. [Universitat Politecnica de Catalunya, Dpt. Fisica i Enginyeria Nuclear, ESAB, Castelldefels, Barcelona (Spain)

    2008-01-15

    The high analytical sensitivity and high spatial resolution of synchrotron radiation-based techniques, in particular SR-XRD and SR-FT-IR, allows the identification of complex micrometric mixtures of compounds that constitute the different layers of ancient paintings. The reliability of the measurements even with an extremely small amount of sampled material is very high, and this is particularly important when analyzing art works. Furthermore, the micro size (10 x 10{mu}m for FT-IR and 30 to 50 {mu}m squared spot size for XRD) of the beam enables one to obtain detailed compositional profiles from the different chromatic and preparation layers. The sensitivity of the techniques is high enough for the determination of minor and trace compounds, such as reaction and weathering compounds. We report here the identification of pigments in the Romanesque wall paintings found in situ in the church of Saint Eulalia of Unha place in the Aran valley (central Pyrenees). During the first centuries of the second millennium numerous religious buildings were built in Western Europe in the Romanesque style. In particular, a great number of churches were built in the Pyrenees, most of which were decorated with wall paintings. Although only a few of these paintings have survived, they represent one of the most important collections of Romanesque art, both for their quantity and quality. A full identification of the pigments, binder, supports, and reaction and weathering compounds has been obtained. The results obtained, in particular aerinite as a pigment, indicate a clear connection between the paintings found in this Occitanian church and the Catalan Romanesque paintings from the south bound of the Pyrenees. (orig.)

  9. Egyptian Tomb Painting.

    Science.gov (United States)

    Schroeder, Liesa

    1999-01-01

    Provides an activity where sixth-grade students replicated the Egyptian art form of tomb painting. Explains that the students researched information about Egyptian culture and history in order to familiarize themselves with Egyptian wall-painting style. Discusses the process of creating tomb paintings in detail. (CMK)

  10. Identification of lapis-lazuli pigments in paint layers by PIGE measurements

    Science.gov (United States)

    Grassi, N.; Migliori, A.; Mandò, P. A.; Calvo del Castillo, H.

    2004-06-01

    Lapis-lazuli is a semi-precious stone used in the past to produce a blue pigment. Its main component is lazurite, 3Na 2O·3Al 2O 3·6SiO 2·2Na 2S. The possibility of using PIXE to identify this pigment in canvas and wood painting is severely limited by the strong absorption of low-energy X-rays in the protective varnish and - when, as typical, the pigment is mixed with lead white - by the overlapping of Pb M lines with S K α. In this work we discuss the possibility of identifying lapis-lazuli by detecting sodium with PIGE. PIXE and PIGE measurements have been performed on samples containing lapis-lazuli mixed to lead white in different percentage, covered with polymeric foils to simulate the presence of varnish. At a percentage of lapis-lazuli below 50%, Na X-rays are hardly detectable even with the thinner foil; on the contrary the characteristic γ-rays are clearly detected down to about 1%. A first application has been successfully performed on the "Madonna dei fusi" by Leonardo da Vinci, in the framework of an extensive scientific investigation on the painting techniques used by the Renaissance genius.

  11. Title: variations and sensitivities of some blood pressure monitors ...

    African Journals Online (AJOL)

    Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Accuracy in blood pressure meters is of essence to health, especially in blood pressure monitoring and treatment. The aim of this research was to compare the readings and the sensitivities of some blood pressure monitors in use ...

  12. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  13. Thermal and pressure pain sensitivity in patients with unilateral shoulder pain: comparison of involved and uninvolved sides.

    Science.gov (United States)

    Coronado, Rogelio A; Kindler, Lindsay L; Valencia, Carolina; George, Steven Z

    2011-03-01

    Cross-sectional. In the examination of patients with unilateral shoulder pain, pain provocation testing to compare the involved and uninvolved sides has been considered useful. However, side-to-side comparisons of experimental pain sensitivity in patients with unilateral shoulder pain are not widely reported in the literature. To compare experimental pain sensitivity between the involved and uninvolved sides in patients with unilateral shoulder pain. In consecutive patients seeking operative treatment for shoulder pain, sensitivity measures of bilateral pressure pain threshold at the shoulder and forearm, and thermal pain threshold, tolerance, and temporal summation at the forearm, were examined. Pressure sensitivity was tested with a Fischer pressure algometer, and thermal sensitivity with a computer-controlled Medoc neurosensory analyzer. The involved and uninvolved sides were compared with an analysis of variance. Influence of sex and location of testing were considered as covariates in the analysis. Fifty-nine consecutively recruited participants completed experimental pain sensitivity testing. Participants reported significantly lower pressure pain thresholds in the involved side compared to the uninvolved side (F1,56 = 4.96, P = .030). In addition, female compared to male participants demonstrated lower pressure pain thresholds in the bilateral shoulder regions (F1,56 = 10.84, P = .002). There was no difference in thermal pain sensitivity between sides. Average clinical pain intensity was negatively correlated with pressure pain threshold at the involved local site (r = -0.284, P = .029), indicating an influence of clinical pain intensity on local pressure pain. The results of this study provide evidence for higher experimental pressure pain sensitivity in the involved side of patients with unilateral shoulder pain and no difference between sides for thermal pain sensitivity. Females demonstrated higher pain sensitivity than males to pressure stimuli at the

  14. Neutron autoradiography: working-out method and application in investigations of test paintings

    International Nuclear Information System (INIS)

    Kalicki, A.; Panczyk, E.; Rowinska, L.; Sartowska, B.; Walis, L.; Pytel, K.; Pytel, B.; Koziel, A.; Dabkowski, L.; Wierzchnicka, M.; Strzalkowski, L.; Ostrowski, T.

    2001-01-01

    Neutron-induced autoradiography was carried out at MARIA research reactor in Poland. The paintings were exposed to the thermal neutrons. As a result, the radionuclides emitting beta particles and gamma rays were created from some of the elements existing in the painting. Beta particles were detected during successive exposure to a series of X-ray medical-sensitive films. The obtained images--blackening of the films depends mainly on the nuclear characteristic of recorded radionuclides and exposure parameters. The main purpose of this work was to work out a method, build a special stand and test sample paintings using neutron autoradiography. Samples of paintings were investigated and according to the obtained results, optimum test parameters have been selected: neutron irradiation conditions and autoradiographs exposure conditions

  15. Spotlight on topographical pressure pain sensitivity maps: a review

    Directory of Open Access Journals (Sweden)

    Alburquerque-Sendín F

    2018-01-01

    Full Text Available Francisco Alburquerque-Sendín,1 Pascal Madeleine,2 César Fernández-de-las-Peñas,3 Paula Rezende Camargo,4 Tania Fátima Salvini4 1Department of Socio-Sanitary Sciences, Radiology and Physical Medicine, Universidad de Córdoba, Córdoba, Spain; 2Physical Activity and Human Performance Group, SMI, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark; 3Department of Physical Therapy, Occupational Therapy, Physical Medicine and Rehabilitation, Universidad Rey Juan Carlos, Madrid, Spain; 4Department of Physical Therapy, Federal University of São Carlos, São Carlos, SP, Brazil Abstract: Mechanical hyperalgesia defined as decreased pressure pain thresholds (PPTs is commonly associated with pain. In this narrative review, we report the current state of the art within topographical pressure sensitivity maps. Such maps are based on multiple PPT assessments. The PPTs are assessed by an a priori defined grid with special focus on both spatial and temporal summation issues. The grid covers the muscle or the body region of interest using absolute or relative values determined from anatomical landmarks or anthropometric values. The collected PPTs are interpolated by Shepard or Franke and Nielson interpolation methods to create topographical pressure sensitivity maps. This new imaging technique has proven to be valuable in various disciplines including exercise physiology, neurology, physical therapy, occupational medicine, oncology, orthopedics, and sport sciences. The reviewed papers have targeted different body regions like the scalp, low back, neck–shoulder, and upper and lower extremities. The maps have delineated spatial heterogeneity in the pressure pain sensitivity underlining the different extents of pressure pain hyperalgesia in both experimentally induced and disease-associated pain conditions. Furthermore, various intervention studies have proven the utility of topographical pressure pain

  16. Automated full-3D digitization system for documentation of paintings

    Science.gov (United States)

    Karaszewski, Maciej; Adamczyk, Marcin; Sitnik, Robert; Michoński, Jakub; Załuski, Wojciech; Bunsch, Eryk; Bolewicki, Paweł

    2013-05-01

    In this paper, a fully automated 3D digitization system for documentation of paintings is presented. It consists of a specially designed frame system for secure fixing of painting, a custom designed, structured light-based, high-resolution measurement head with no IR and UV emission. This device is automatically positioned in two axes (parallel to the surface of digitized painting) with additional manual positioning in third, perpendicular axis. Manual change of observation angle is also possible around two axes to re-measure even partially shadowed areas. The whole system is built in a way which provides full protection of digitized object (moving elements cannot reach its vicinity) and is driven by computer-controlled, highly precise servomechanisms. It can be used for automatic (without any user attention) and fast measurement of the paintings with some limitation to their properties: maximum size of the picture is 2000mm x 2000mm (with deviation of flatness smaller than 20mm) Measurement head is automatically calibrated by the system and its possible working volume starts from 50mm x 50mm x 20mm (10000 points per square mm) and ends at 120mm x 80mm x 60mm (2500 points per square mm). The directional measurements obtained with this system are automatically initially aligned due to the measurement head's position coordinates known from servomechanisms. After the whole painting is digitized, the measurements are fine-aligned with color-based ICP algorithm to remove any influence of possible inaccuracy of positioning devices. We present exemplary digitization results along with the discussion about the opportunities of analysis which appear for such high-resolution, 3D computer models of paintings.

  17. Color alteration of the paint used for iris painting in ocular prostheses

    Directory of Open Access Journals (Sweden)

    Aline Úrsula Rocha Fernandes

    2009-12-01

    Full Text Available The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05. All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging.

  18. Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

    Science.gov (United States)

    Schreck, Michael J; Kelly, Meghan; Canham, Colin D; Elfar, John C

    2018-01-01

    The alteration of forces across joints can result in instability and subsequent disability. Previous methods of force measurements such as pressure-sensitive films, load cells, and pressure-sensing transducers have been utilized to estimate biomechanical forces across joints and more recent studies have utilized a nondestructive method that allows for assessment of joint forces under ligamentous restraints. A comprehensive review of the literature was performed to explore the numerous biomechanical methods utilized to estimate intra-articular forces. Methods of biomechanical force measurements in joints are reviewed. Methods such as pressure-sensitive films, load cells, and pressure-sensing transducers require significant intra-articular disruption and thus may result in inaccurate measurements, especially in small joints such as those within the wrist and hand. Non-destructive methods of joint force measurements either utilizing distraction-based joint reaction force methods or finite element analysis may offer a more accurate assessment; however, given their recent inception, further studies are needed to improve and validate their use.

  19. High Temperature Dynamic Pressure Measurements Using Silicon Carbide Pressure Sensors

    Science.gov (United States)

    Okojie, Robert S.; Meredith, Roger D.; Chang, Clarence T.; Savrun, Ender

    2014-01-01

    Un-cooled, MEMS-based silicon carbide (SiC) static pressure sensors were used for the first time to measure pressure perturbations at temperatures as high as 600 C during laboratory characterization, and subsequently evaluated in a combustor rig operated under various engine conditions to extract the frequencies that are associated with thermoacoustic instabilities. One SiC sensor was placed directly in the flow stream of the combustor rig while a benchmark commercial water-cooled piezoceramic dynamic pressure transducer was co-located axially but kept some distance away from the hot flow stream. In the combustor rig test, the SiC sensor detected thermoacoustic instabilities across a range of engine operating conditions, amplitude magnitude as low as 0.5 psi at 585 C, in good agreement with the benchmark piezoceramic sensor. The SiC sensor experienced low signal to noise ratio at higher temperature, primarily due to the fact that it was a static sensor with low sensitivity.

  20. Sensitivity analysis of a PWR pressurizer

    International Nuclear Information System (INIS)

    Bruel, Renata Nunes

    1997-01-01

    A sensitivity analysis relative to the parameters and modelling of the physical process in a PWR pressurizer has been performed. The sensitivity analysis was developed by implementing the key parameters and theoretical model lings which generated a comprehensive matrix of influences of each changes analysed. The major influences that have been observed were the flashing phenomenon and the steam condensation on the spray drops. The present analysis is also applicable to the several theoretical and experimental areas. (author)

  1. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  2. Workplace protection of air-fed visors used in paint spraying operations.

    Science.gov (United States)

    Bolsover, J; Rajan-Sithamparanadarajah, B; Vaughan, N

    2006-04-01

    Air-fed visors are commonly used for protection against exposure to airborne isocyanates during paint spraying. Protection levels for this class of equipment are theoretically adequate, yet isocyanate sensitization in this occupation still occurs. The work reported here set out to establish the level of respiratory protection that is achieved during real paint spraying activities when air-fed visors are used. The work also examined the effects of reduced air supply flow rates on this type of respiratory protection. The workplace study highlighted common problems that occur when attempting to measure protection factors, and process and interpret the collected data. Many of the environments included in this study did not exhibit challenge concentrations high enough to reliably measure the workplace protection factor of this class of device. When detection limits are taken into consideration, the remaining field data suggest that an assigned protection factor in the region of 40 may be appropriate. When well maintained and used in accordance with the manufacturer's instructions, air-fed visors are capable of providing a good level of respiratory protection. The protection given by air-fed visors is strongly dependent on the air flow supplied to them. Laboratory measurements demonstrate that protection falls as the air supply falls. This is a gradual process and does not suddenly occur at any particular air supply flow. Observations made during the field tests indicate that there may be other activities associated with the spraying process that need to be taken into consideration when looking for sources of respiratory sensitization.

  3. A Miniaturized Carbon Dioxide Gas Sensor Based on Sensing of pH-Sensitive Hydrogel Swelling with a Pressure Sensor

    NARCIS (Netherlands)

    Herber, S.; Bomer, Johan G.; Olthuis, Wouter; Bergveld, Piet; van den Berg, Albert

    2005-01-01

    A measurement concept has been realized for the detection of carbon dioxide, where the CO2 induced pressure generation by an enclosed pH-sensitive hydrogel is measured with a micro pressure sensor. The application of the sensor is the quantification of the partial pressure of CO2 (Pco2) in the

  4. Exhalation velocity of radon-222 of Dutch building materials and the influence of paint systems

    International Nuclear Information System (INIS)

    Dijk, W. van; Jong, P. de

    1989-02-01

    In order to achieve a better insight concerning the source terms of radon in the Dutch dwelling in the framework of the RENA-programme an investigation has been performed into the exhalation velocity of radon-222 from building materials. From this investigation it turned out that the ventilation factor does not have any influence upon the exhalation velocity, neither an influence of alteration of air pressure could be demonstrated. The influence of air humidity upon the exhalation velocity showed a twofold picture; for gypsum a linear increase of the exhalation velocity with vapour pressure was found, while for concrete a linear decrease with vapour pressure was observed. Further it has been investigated in how far paint systems diminish the exhalation velocity of the Rn-222 from gypsum and concrete. Acryl paints, mostly used in the Dutch dwelling, did not show a decrease of the exhalation velocity and structure paints did even cause an increase of the exhalation velocity. Other types of paint based on chlorous rubber, epoxy resins and poly-urethane, in contrast, showed a clear reduction. From these those based on poly-urethane showed the largest reduction (60-75%) at a double sided treatment of the wall. With the help of a mathematical modelling of the exhalation estimations have been made of the exhalation velocity of Rn-222 at single sided treatment of a wall and for the exhalation velocity of Rn-220. For the fore mentioned poly-urethane-paints this yelds, at an estimate, a reduction of respectively 90-95% and 100%. (author). 40 refs.; 15 figs.; 8 tabs

  5. Highly Sensitive Reentrant Cavity-Microstrip Patch Antenna Integrated Wireless Passive Pressure Sensor for High Temperature Applications

    Directory of Open Access Journals (Sweden)

    Fei Lu

    2017-01-01

    Full Text Available A novel reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor was proposed in this paper for high temperature applications. The reentrant cavity was analyzed from aspects of distributed model and equivalent lumped circuit model, on the basis of which an optimal sensor structure integrated with a rectangular microstrip patch antenna was proposed to better transmit/receive wireless signals. In this paper, the proposed sensor was fabricated with high temperature resistant alumina ceramic and silver metalization with weld sealing, and it was measured in a hermetic metal tank with nitrogen pressure loading. It was verified that the sensor was highly sensitive, keeping stable performance up to 300 kPa with an average sensitivity of 981.8 kHz/kPa at temperature 25°C, while, for high temperature measurement, the sensor can operate properly under pressure of 60–120 kPa in the temperature range of 25–300°C with maximum pressure sensitivity of 179.2 kHz/kPa. In practical application, the proposed sensor is used in a method called table lookup with a maximum error of 5.78%.

  6. Oil-based paint poisoning

    Science.gov (United States)

    Paint - oil-based - poisoning ... Hydrocarbons are the primary poisonous ingredient in oil paints. Some oil paints have heavy metals such as lead, mercury, cobalt, and barium added as pigment. These heavy metals can cause additional ...

  7. Process Waste Assessment - Paint Shop

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1993-06-01

    This Process Waste Assessment was conducted to evaluate hazardous wastes generated in the Paint Shop, Building 913, Room 130. Special attention is given to waste streams generated by the spray painting process because it requires a number of steps for preparing, priming, and painting an object. Also, the spray paint booth covers the largest area in R-130. The largest and most costly waste stream to dispose of is open-quote Paint Shop wasteclose quotes -- a combination of paint cans, rags, sticks, filters, and paper containers. These items are compacted in 55-gallon drums and disposed of as solid hazardous waste. Recommendations are made for minimizing waste in the Paint Shop. Paint Shop personnel are very aware of the need to minimize hazardous wastes and are continuously looking for opportunities to do so

  8. A study of paint sludge deactivation by pyrolysis reactions

    Directory of Open Access Journals (Sweden)

    Muniz L.A.R.

    2003-01-01

    Full Text Available The production of large quantities of paint sludge is a serious environmental problem. This work evaluates the use of pyrolysis reaction as a process for deactivating paint sludge that generates a combustible gas phase, a solvent liquid phase and an inert solid phase. These wastes were classified into three types: water-based solvent (latex resin and solvents based on their resins (alkyd and polyurethane. An electrically heated stainless steel batch reactor with a capacity of 579 mL and a maximum pressure of 30 atm was used. Following the reactor, a flash separator, which was operated at atmospheric pressure, partially condensed and separated liquid and gas products. Pressure and temperature were monitored on-line by a control and data acquisition system, which adjusted the heating power supplied to the pyrolysis reactor. Reactions followed an experimental design with two factors (reaction time and temperature and three levels (10, 50 and 90 minutes; 450, 550 and 650degreesC. The response variables were liquid and solid masses and net heat of combustion. The optimal operational range for the pyrolysis process was obtained for each response variable. A significant reduction in total mass of solid waste was obtained.

  9. Tilted c-Axis Thin-Film Bulk Wave Resonant Pressure Sensors With Improved Sensitivity

    OpenAIRE

    Anderås, Emil; Katardjiev, Ilia; Yantchev, Ventsislav

    2012-01-01

    Aluminum nitride thin film bulk wave resonant pressure sensors employing c- and tilted c-axis texture, have been fabricated and tested for their pressure sensitivities. The c-axis tilted FBAR pressure sensors demonstrate substantially higher pressure sensitivity compared to its c-axis oriented counterpart. More specifically the thickness plate quasi-shear resonance has demonstrated the highest pressure sensitivity while further being able to preserve its performance in liquid environment.

  10. Difference in brain activations during appreciating paintings and photographic analogues

    Directory of Open Access Journals (Sweden)

    Yoshinori eMizokami

    2014-07-01

    Full Text Available Several studies have investigated neural correlates of aesthetic appreciation for paintings but to date the findings have been heterogeneous. This heterogeneity may be attributed to previous studies’ measurement of aesthetic appreciation of not only the beauty of paintings but also the beauty of motifs of the paintings. In order to better elucidate the beauty of paintings, it seems necessary to compare aesthetic appreciation of paintings and photographic analogues which included corresponding real images. We prepared for famous painters’ pictures and their photographic analogues which were set up to resemble each painting in order to investigate the hypothesis that there exist specific neural correlates associated with the aesthetic appreciation for paintings. Forty-four subjects participated in functional magnetic resonance study which required comparisons of aesthetic appreciation of paintings of still life and landscape versus photographic analogues including corresponding real images of still life and landscape. Bilateral cuneus and the left lingual gyrus were activated in the comparison of aesthetic appreciation of paintings versus photographic analogues. In conclusion, the present findings suggest a possibility of the existence of specific neural correlates associated with the aesthetic appreciation for paintings and that bilateral cuneus and the left lingual gyrus may be involved.

  11. Characterizing microbial diversity and damage in mural paintings.

    Science.gov (United States)

    Rosado, Tânia; Mirão, José; Candeias, António; Caldeira, Ana Teresa

    2015-02-01

    Mural paintings are some of the oldest and most important cultural expressions of mankind and play an important role for the understanding of societies and civilizations. These cultural assets have high economic and cultural value and therefore their degradation has social and economic impact. The present work presents a novel microanalytical approach to understand the damages caused by microbial communities in mural paintings. This comprises the characterization and identification of microbial diversity and evaluation of damage promoted by their biological activity. Culture-dependent methods and DNA-based approaches like denaturing gradient gel electrophoresis (DGGE) and pyrosequencing are important tools in the isolation and identification of the microbial communities allowing characterization of the biota involved in the biodeterioration phenomena. Raman microspectrometry, infrared spectrometry, and variable pressure scanning electron microscopy coupled with energy-dispersive X-ray spectrometry are also useful tools for evaluation of the presence of microbial contamination and detection of the alteration products resulting from metabolic activity of the microorganisms. This study shows that the degradation status of mural paintings can be correlated to the presence of metabolically active microorganisms.

  12. Nondestructive analysis of automotive paints with spectral domain optical coherence tomography.

    Science.gov (United States)

    Dong, Yue; Lawman, Samuel; Zheng, Yalin; Williams, Dominic; Zhang, Jinke; Shen, Yao-Chun

    2016-05-01

    We have demonstrated for the first time, to our knowledge, the use of optical coherence tomography (OCT) as an analytical tool for nondestructively characterizing the individual paint layer thickness of multiple layered automotive paints. A graph-based segmentation method was used for automatic analysis of the thickness distribution for the top layers of solid color paints. The thicknesses measured with OCT were in good agreement with the optical microscope and ultrasonic techniques that are the current standard in the automobile industry. Because of its high axial resolution (5.5 μm), the OCT technique was shown to be able to resolve the thickness of individual paint layers down to 11 μm. With its high lateral resolution (12.4 μm), the OCT system was also able to measure the cross-sectional area of the aluminum flakes in a metallic automotive paint. The range of values measured was 300-1850  μm2. In summary, the proposed OCT is a noncontact, high-resolution technique that has the potential for inclusion as part of the quality assurance process in automobile coating.

  13. Piezoelectric paints as one approach to smart structural materials with health-monitoring capabilities

    Science.gov (United States)

    Egusa, Shigenori; Iwasawa, Naozumi

    1998-08-01

    Piezoelectric paints have a potential to change a conventional structural material into an intelligent material system with health-monitoring capabilities such as vibration sensing and damage detection. Such paints were prepared using lead zirconate titanate (PZT) ceramic powder as a pigment and epoxy resin as a binder. The obtained paints were coated on aluminum test specimens, and were cured at room temperature or at 150 0964-1726/7/4/002/img5, thus forming the paint films having different thicknesses of 25-300 0964-1726/7/4/002/img6. These films were then poled at room temperature, and were evaluated with regard to the sensitivities as vibration and acoustic emission sensors in the frequency ranges of 0-250 Hz and 0-1.0 MHz, respectively. This paper mainly describes the effects of the film thickness and the cure temperature on the poling behavior of the PZT/epoxy paint film. This paper describes also the application of the paint film as a vibration modal sensor integrated into a structural material.

  14. Plasticity of pressure-sensitive materials

    CERN Document Server

    Ochsner, Andreas

    2014-01-01

    Classical plasticity theory of metals is independent of the hydrostatic pressure. However, if the metal contains voids or pores or if the structure is composed of cells, this classical assumption is no more valid and the influence of the hydrostatic pressure must be incorporated in the constitutive description. Looking at the microlevel, metal plasticity is connected with the uniform planes of atoms organized with long-range order. Planes may slip past each other along their close-packed directions. The result is a permanent change of shape within the crystal and plastic deformation. The presence of dislocations increases the likelihood of planes slipping. Nowadays, the theory of pressure sensitive plasticity is successfully applied to many other important classes of materials (polymers, concrete, bones etc.) even if the phenomena on the micro-level are different to classical plasticity of metals. The theoretical background of this phenomenological approach based on observations on the macro-level is describe...

  15. Selective paint coatings for coloured solar absorbers: Polyurethane thickness insensitive spectrally selective (TISS) paints (Part II)

    Energy Technology Data Exchange (ETDEWEB)

    Orel, B.; Spreizer, H.; Surca Vuk, A.; Fir, M. [National Institute of Chemistry, Hajdrihova 19, SI-1000 Ljubljana (Slovenia); Merlini, D.; Vodlan, M. [Color d.d., Cesta komandanta Staneta 4, SI-1230 Medvode (Slovenia); Koehl, M. [Fraunhofer-Institute for Solar Energy Systems ISE, Heidenhofstr. 2, D-79110 Freiburg (Germany)

    2007-01-23

    Red, green and blue paints were prepared for use as thickness insensitive spectrally selective (TISS) paint coatings for solar facade absorbers. The paints were composed of a polyurethane resin binder in which various pigments were incorporated in such a way that they formed stable paint dispersions, satisfying stability criteria for facade coatings. A low emittance of the paints was achieved by using low-emittance aluminium flake pigments combined with iron oxide (red coloured paints). Black pigment was added to adjust solar absorptance. Blue and green paints were made by the addition of coloured aluminium flake pigment and the solar absorptance was also adjusted by the addition of black pigment. Efficiency for photo-thermal conversion of solar radiation was assessed by evaluation of the corresponding performance criteria, which enabled the selection of paints whose performance criteria values were higher than 0 (spectrally non-selective black coating). The results confirmed that blue and green paints and to minor extent red ones, combined selectivity with colour. The morphology of the paints was assessed, revealing that the colours originated from the deposition of finely dispersed colour and/or black pigment on the surface of the aluminium flakes during paint preparation. (author)

  16. Measurement, modeling and perception of painted surfaces: A Multi-scale Analysis of the Touch-up Problem

    Science.gov (United States)

    Kalghatgi, Suparna Kishore

    Real-world surfaces typically have geometric features at a range of spatial scales. At the microscale, opaque surfaces are often characterized by bidirectional reflectance distribution functions (BRDF), which describes how a surface scatters incident light. At the mesoscale, surfaces often exhibit visible texture -- stochastic or patterned arrangements of geometric features that provide visual information about surface properties such as roughness, smoothness, softness, etc. These textures also affect how light is scattered by the surface, but the effects are at a different spatial scale than those captured by the BRDF. Through this research, we investigate how microscale and mesoscale surface properties interact to contribute to overall surface appearance. This behavior is also the cause of the well-known "touch-up problem" in the paint industry, where two regions coated with exactly the same paint, look different in color, gloss and/or texture because of differences in application methods. At first, samples were created by applying latex paint to standard wallboard surfaces. Two application methods- spraying and rolling were used. The BRDF and texture properties of the samples were measured, which revealed differences at both the microscale and mesoscale. This data was then used as input for a physically-based image synthesis algorithm, to generate realistic images of the surfaces under different viewing conditions. In order to understand the factors that govern touch-up visibility, psychophysical tests were conducted using calibrated, digital photographs of the samples as stimuli. Images were presented in pairs and a two alternative forced choice design was used for the experiments. These judgments were then used as data for a Thurstonian scaling analysis to produce psychophysical scales of visibility, which helped determine the effect of paint formulation, application methods, and viewing and illumination conditions on the touch-up problem. The results can be

  17. Fiber optic pressure sensors in skin-friction measurements

    Science.gov (United States)

    Cuomo, F. W.

    1986-01-01

    A fiber optic lever sensing technique that can be used to measure normal pressure as well as shear stresses is discussed. This method uses three unequal fibers combining small size and good sensitivity. Static measurements appear to confirm the theoretical models predicted by geometrical optics and dynamic tests performed at frequencies up to 10 kHz indicate a flat response within this frequency range. These sensors are intended for use in a low speed wind tunnel environment.

  18. Three-dimensional micro-XRF investigations of paint layers with a tabletop setup

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit; Malzer, Wolfgang; Rodriguez, Alexis Fuentes; Reiche, Ina

    2005-01-01

    The non-destructive investigation of art and archaeological objects with depth sensitivity is now possible using 3D micro-XRF spectroscopy. More detailed answers for questions on painting techniques, on the pigment palette, on the production processes and indirectly on dating or provenancing of objects are accessible now. This was already illustrated by the investigation of Mughal miniatures with a confocal setup at the synchrotron source BESSY. In this paper we demonstrate the feasibility of 3D micro-XRF spectroscopy with a tabletop setup and discuss its sensitivity in comparison to the synchrotron-based setup. Investigated objects are glass standards and also prepared paint layers. Perspectives for other types of studies are proposed

  19. Association between Pressure Pain Sensitivity, Performance stability and Overall Performance in Olympic Sailors

    DEFF Research Database (Denmark)

    Faber, Jens Oscar; Ballegaard, Søren

    2016-01-01

    Background: During sports competitions, the performance of athletes may be negatively affected by persistent stress and autonomic nervous system (ANS) dysfunction, both of which can be assessed by pressure pain sensitivity (PPS) at the chest bone. Objectives: To test the association between PPS......: r > 0.70; p stress and ANS dysfunction as assessed by PPS on one side and performance stability and overall performance on the other side. Keywords Autonomic nervous system dysfunction; Pressure pain sensitivity; Sports...... guide for persistent stress and ANS dysfunction. Performance stability, overall performance and PPS measure were assessed at three intervals. Results: At baseline, the median PPS was 83, the performance stability was inferior to the mean top 10 competitors, and the overall performance was rank eight...

  20. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection

    Science.gov (United States)

    Zang, Yaping; Zhang, Fengjiao; Huang, Dazhen; Gao, Xike; di, Chong-An; Zhu, Daoben

    2015-03-01

    The utilization of organic devices as pressure-sensing elements in artificial intelligence and healthcare applications represents a fascinating opportunity for the next-generation electronic products. To satisfy the critical requirements of these promising applications, the low-cost construction of large-area ultra-sensitive organic pressure devices with outstanding flexibility is highly desired. Here we present flexible suspended gate organic thin-film transistors (SGOTFTs) as a model platform that enables ultra-sensitive pressure detection. More importantly, the unique device geometry of SGOTFTs allows the fine-tuning of their sensitivity by the suspended gate. An unprecedented sensitivity of 192 kPa-1, a low limit-of-detection pressure of <0.5 Pa and a short response time of 10 ms were successfully realized, allowing the real-time detection of acoustic waves. These excellent sensing properties of SGOTFTs, together with their advantages of facile large-area fabrication and versatility in detecting various pressure signals, make SGOTFTs a powerful strategy for spatial pressure mapping in practical applications.

  1. Studies on the temperature distribution of steel plates with different paints under solar radiation

    International Nuclear Information System (INIS)

    Liu, Hongbo; Chen, Zhihua; Chen, Binbin; Xiao, Xiao; Wang, Xiaodun

    2014-01-01

    Thermal effects on steel structures exposed to solar radiation are significant and complicated. Furthermore, the solar radiation absorption coefficient of steel surface with different paintings is the main factor affecting the non-uniform temperature of spatial structures under solar radiation. In this paper, nearly two hundreds steel specimens with different paintings were designed and measured to obtain their solar radiation absorption coefficients using spectrophotometer. Based on the test results, the effect of surface color, painting type, painting thickness on the solar radiation absorption coefficient was analyzed. The actual temperatures under solar radiation for all specimens were also measured in summer not only to verify the absorption coefficient but also provide insight for the temperature distribution of steel structures with different paintings. A numerical simulation and simplified formula were also conducted and verified by test, in order to study the temperature distribution of steel plates with different paints under solar radiation. The results have given an important reference in the future research of thermal effect of steel structures exposed to solar radiation. - Highlights: • Solar radiation absorptions for steel with different paintings were measured. • The temperatures of all specimens under solar radiation were measured. • The effect of color, thickness and painting type on solar absorption was analyzed. • A numerical analysis was conducted and verified by test data. • A simplified formula was deduced and verified by test data

  2. Bacteria isolated from rock art paintings: the case of Atlanterra shelter (south Spain).

    Science.gov (United States)

    Gonzalez, I; Laiz, L; Hermosin, B; Caballero, B; Incerti, C; Saiz-Jimenez, C

    1999-05-01

    The Sierra de la Plata is an Aljibe yellow sandstone formation from the Acheulian period. There are a few shelters, some of them with rock art paintings. The most representative one, and subjected to anthropogenic pressure, is that of Atlanterra, situated in a residential area. This shelter contains some rock art paintings made with iron oxides. The bacteria present in these paintings were isolated and identified using an automatic method: fatty acid methyl esters profiling. Most of the bacteria belong to the Bacillus genus, B. megaterium being the most abundant species. The isolated strains are able to reduce hematite. This is significant due to the fact that Fe(III)-(hydr)oxides are the most abundant pigments in rock art.

  3. Lead content of dried films of domestic paints currently sold in Nigeria

    International Nuclear Information System (INIS)

    Adebamowo, Eugenious O.; Scott Clark, C.; Roda, Sandy; Agbede, Oluwole A.; Sridhar, Mynepalli K.C.; Adebamowo, Clement A.

    2007-01-01

    Children are at higher risk from lead exposure because their developing neural system is susceptible to its neurotoxic effects. We studied lead levels of paints manufactured in Nigeria in 2006. Lead levels in 5 colors of paints, each from different manufacturers were measured using flame-atomic absorption spectroscopy. We found that 96% of the paints had higher than recommended levels of lead. The mean lead level of paints ranged from 84.8 to 50,000 ppm, with mean of 14,500 ppm and median of 15,800 ppm. The main determinant of lead levels was color of the paint. As lead levels in paint sold in the past years in Nigeria are likely to be at least as high as that currently sold, it is likely that many existing houses contain dangerously high levels of lead. Efforts need to be undertaken to assess the presence of high lead levels in existing housing and if detected, intervention programs for eliminating risk of exposure should be developed in addition to measures to increase awareness and enforce regulations leading to the elimination of lead based domestic paint

  4. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  5. Direct Emissivity Measurements of Painted Metals for Improved Temperature Estimation During Laser Damage Testing

    Science.gov (United States)

    2014-03-27

    policy or position of the United States Air Force, the Department of Defense, or the United States Government . This material is declared a work of the...U.S. Government and is not subject to copyright protection in the United States. AFIT-ENP-14-M-43 DIRECT EMISSIVITY MEASUREMENTS OF PAINTED METALS FOR...Source The laser probe in use for this test is a Daylight Solutions Unicorn II quantum cascade laser operating at 3.77 µm. According to the laser

  6. Highly sensitive multi-layer pressure sensor with an active nanostructured layer of an organic molecular metal

    International Nuclear Information System (INIS)

    Laukhin, V; Lebedev, V; Laukhina, E; Rovira, C; Veciana, J

    2016-01-01

    This work addresses to the modern technologies that need to be instrumented with lightweight highly sensitive pressure sensors. The paper presents the development of a new plain flexible thin pressure sensor using a nanostructured layer of the highly sensitive organic piezoresistive metal β-(BEDT-TTF) 2 I 3 as an active component; BEDT-TTF=bis (ethylenedithio)tetrathiafulvalene. The original construction approach permits one to operate the developed sensor on the principle of electrical resistance variations when its piezoresistive layer is elongated under a pressure increase. The pressure sensing element and a set of gold electrodes were integrated into one compact multi-layer design. The construction was optimized to enable one generic design for pressure ranges from 1 to 400 bar. The pressure tests showed that the sensor is able to control a small pressure change as a well definite electrical signal. So the developed type of the sensors is very attractive as a new generation of compact, lightweight, low-cost sensors that might monitor pressure with a good level of measurement accuracy. (paper)

  7. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  8. Conception and preliminary evaluation of an optical fibre sensor for simultaneous measurement of pressure and temperature

    International Nuclear Information System (INIS)

    Bremer, K; Moss, B; Leen, G; Mueller, I; Lewis, E; Lochmann, S

    2009-01-01

    This paper presents a novel concept of simultaneously measuring pressure and temperature using a silica optical fibre extrinsic Fabry-Perot interferometric (EFPI) pressure sensor incorporating a fibre Bragg grating (FBG), which is constructed entirely from fused-silica. The novel device is used to simultaneously provide accurate pressure and temperature readings at the point of measurement. Furthermore, the FBG temperature measurement is used to eliminate the temperature cross-sensitivity of the EFPI pressure sensor.

  9. A laboratory measurement method for pressure sensitive adhesives in agglomeration deinking of mixed office waste paper: The high-low scanning contrast method

    OpenAIRE

    Guolin Tong; Shuang Sun; Cuixia Wang; Kecheng Fu; Yungchang F. Chin

    2012-01-01

    A simple measurement method for pressure sensitive adhesives (PSA) in an agglomeration deinking system of mixed office waste paper was studied. This method was based on the different scanning performance of ink and PSA specks in hot-pressed and oven-dried handsheets with the change of contrast values that had been selected and set in the image analysis software. The numbers of ink specks per square meter (NPM) were well recognized at both low and high contrast values and exhibited a very good...

  10. Investigation of leaching of an antifouling agent from marine paint formulations using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Kalgutkar, D.B.; Patil, S.P.; Jayachandran, N.; Unni, V.K.P.

    2012-01-01

    A radiotracer technique was used to investigate the leaching of an antifouling agent from different marine paint formulations with an objective to select the best paint formulation for bulk production. The antifouling agent (Diuron) itself was labeled with carbon-14 (half-life: 5,730 years, β-energy: 156 keV) and used as a radiotracer. The different paint formulations added with radiolabeled Diuron were applied onto suitably selected substrates and measured for initial intensity of β-radiation using a Geiger-Muller detector connected to a ratemeter. The painted substrates were subjected to shower tests for a pre-decided time and subsequently measured for β-radiations. The comparison of intensity of β-radiations in substrates prior and post shower tests provides information about leaching of antifouling agent Diuron from the paint formulation. The high leaching percentage of antifouling agent Diuron post shower tests indicates non-suitability of paint formulation for marine and civil structures. However, low leaching rate of Diuron will make a paint formulation more efficient and suitable. Based on the results of investigation, a paint formulation with minimum leaching rate was identified and selected for bulk production by a paint company. (author)

  11. The total hemispheric emissivity of painted aluminum honeycomb at cryogenic temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Tuttle, J.; Canavan, E.; DiPirro, M.; Li, X. [NASA Goddard Space Flight Center, Code 552 Greenbelt, Maryland, 20771 (United States); Knollenberg, P. [Northrop Grumman Aerospace Systems Redondo Beach, CA 90278 (United States)

    2014-01-29

    NASA uses high-emissivity surfaces on deep-space radiators and thermal radiation absorbers in test chambers. Aluminum honeycomb core material, when coated with a high-emissivity paint, provides a lightweight, mechanically robust, and relatively inexpensive black surface that retains its high emissivity down to low temperatures. At temperatures below about 100 Kelvin, this material performs much better than the paint itself. We measured the total hemispheric emissivity of various painted honeycomb configurations using an adaptation of an innovative technique developed for characterizing thin black coatings. These measurements were performed from room temperature down to 30 Kelvin. We describe the measurement technique and compare the results with predictions from a detailed thermal model of each honeycomb configuration.

  12. Hierarchical Micro-Nano Coatings by Painting

    Science.gov (United States)

    Kirveslahti, Anna; Korhonen, Tuulia; Suvanto, Mika; Pakkanen, Tapani A.

    2016-03-01

    In this paper, the wettability properties of coatings with hierarchical surface structures and low surface energy were studied. Hierarchically structured coatings were produced by using hydrophobic fumed silica nanoparticles and polytetrafluoroethylene (PTFE) microparticles as additives in polyester (PES) and polyvinyldifluoride (PVDF). These particles created hierarchical micro-nano structures on the paint surfaces and lowered or supported the already low surface energy of the paint. Two standard application techniques for paint application were employed and the presented coatings are suitable for mass production and use in large surface areas. By regulating the particle concentrations, it was possible to modify wettability properties gradually. Highly hydrophobic surfaces were achieved with the highest contact angle of 165∘. Dynamic contact angle measurements were carried out for a set of selected samples and low hysteresis was obtained. Produced coatings possessed long lasting durability in the air and in underwater conditions.

  13. Observations of peeling of a polyisobutynele-based pressure-sensitive adhesive

    DEFF Research Database (Denmark)

    Christensen, Søren. F.; Everland, Hanne.; Hassager, Ole

    1998-01-01

    A pressure-sensitive adhesive(PSA) was prepared by mixing low- and high-molecular-weight polyisobutylenes(PIB). Peeling of the adhesive from polycarbonate was observed from the side and from below at three different peel rates.......A pressure-sensitive adhesive(PSA) was prepared by mixing low- and high-molecular-weight polyisobutylenes(PIB). Peeling of the adhesive from polycarbonate was observed from the side and from below at three different peel rates....

  14. Effect of ionizing radiation on properties of acrylic pressure sensitive adhesives

    International Nuclear Information System (INIS)

    Panta, P.P.; Zimek, Z.A.; Giuszewski, W.; Kowalewski, R.; Wojtynska, E.; Wnuk, A.

    1998-01-01

    Pressure-sensitive adhesives for technical application are widely produced. The biological properties of adhesives depend on the type of monomers used. The available literature data as experience of the authors of this study in the area of pressure-sensitive acrylic adhesive, polymers used in medicine, polymerisation in aqueous media, radiation sterilization, permit to make an assumption that it is possible to elaborate the technology of production of pressure-sensitive adhesives in aqueous emulsion for medical applications. Identification of phenomena influencing the adhesive properties, especially its adhesion, cohesion, tack and durability is of great importance. The control of polymer structure is performed by means of adequate selection of conditions of synthesis and parameters of radiation processing. The authors investigate the influence on the final products of such factors as the type and amount of monomers used, their mutual ratio, as well as the ratio monomers and the dose of ionising radiation. There is no available literature information concerning the investigation of resistance of acrylic emulsion adhesive to sterilisation by electron beam. It is known from unpublished research that some adhesives are resistant to radiation, while others undergo destruction. It probably depends on the composition of emulsion, specifically on the additives which modify adhesives. Simultaneous achievement of good cohesion and adhesion in the case of such types of pressure sensitive adhesives is very difficult pressure sensitive adhesives is very difficult

  15. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  16. Dissolution of organic solvents from painted surfaces into water

    International Nuclear Information System (INIS)

    Wren, J.C.; Jobe, D.J.; Sanipelli, G.G.; Ball, J.M.

    2000-01-01

    The presence of volatile iodine in containment buildings is one of the major safety concerns in the potential event of nuclear reactor accidents. Organic impurities in containment water, originating from various painted structural surfaces and organic materials, could have a significant impact on iodine volatility following an accident. To determine the source and magnitude of organic impurities and their effects on time-dependent iodine volatility, the dissolution for organic constituents from paints used in reactor buildings has been studied under postulated accident conditions. The studies of the organic dissolution from carbon steel coupons coated with zinc-primed vinyl, epoxy-primed polyurethane or epoxy paints over the temperature range 25-90 deg C are reported. Relatively large activation energies were measured for the release of the principal organic compounds from painted surfaces, suggesting it is the release of the solvents from the paint matrix rather than their diffusion through the solution that is the rate determining step for the dissolution mechanism. The similarities in the values of activation energies for the dissolution of different organic compounds from the paints suggest the release rate is independent of the nature of the painted surface or the type of organic being released from the surface. These two observations indicate that it may be possible to write a generalized rate expression for the release of organic compounds from painted surfaces in containment following an accident. The possible implications of these results for predicting iodine volatility in containment are also discussed. (author)

  17. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  18. Self Cleaning Paint: Introduction of Photocatalytic Particles into a Paint System

    DEFF Research Database (Denmark)

    Gunnarsson, Sverrir Grimur

    The current industrial PhD work was aimed at synthesising a photocatalytic composite material which could be used to give organic wood paint films self-cleaning and anti-microbial properties. The current PhD work was done in collaboration between Dyrup A/S and Technical University of Denmark...... consists of an introduction to relevant concepts and literature followed by results, presented as research papers, and a patent application. Four research papers are introduced as individual chapters. Chapter 4 discusses the synthesis and optimisation of anatase TiO2 coated microspheres, chapter 5......-cleaning coatings containing TiO2 coated microspheres. The results show that introducing a photocatalyst into an organic paint system as a coating on inert carrier particles results in durable and weather stable paint films. The paint films exhibit selfcleaning properties and are able to resist the attack of micro...

  19. Boundary-Layer Detection at Cryogenic Conditions Using Temperature Sensitive Paint Coupled with a Carbon Nanotube Heating Layer

    Directory of Open Access Journals (Sweden)

    Kyle Z. Goodman

    2016-12-01

    Full Text Available Detection of flow transition on aircraft surfaces and models can be vital to the development of future vehicles and computational methods for evaluating vehicle concepts. In testing at ambient conditions, IR thermography is ideal for this measurement. However, for higher Reynolds number testing, cryogenic facilities are often used, in which IR thermography is difficult to employ. In these facilities, temperature sensitive paint is an alternative with a temperature step introduced to enhance the natural temperature change from transition. Traditional methods for inducing the temperature step by changing the liquid nitrogen injection rate often change the tunnel conditions. Recent work has shown that adding a layer consisting of carbon nanotubes to the surface can be used to impart a temperature step on the model surface with little change in the operating conditions. Unfortunately, this system physically degraded at 130 K and lost heating capability. This paper describes a modification of this technique enabling operation down to at least 77 K, well below the temperature reached in cryogenic facilities. This is possible because the CNT layer is in a polyurethane binder. This was tested on a Natural Laminar Flow model in a cryogenic facility and transition detection was successfully visualized at conditions from 200 K to 110 K. Results were also compared with the traditional temperature step method.

  20. Boundary-Layer Detection at Cryogenic Conditions Using Temperature Sensitive Paint Coupled with a Carbon Nanotube Heating Layer

    Science.gov (United States)

    Goodman, Kyle Z.; Lipford, William E.; Watkins, Anthony Neal

    2016-01-01

    Detection of flow transition on aircraft surfaces and models can be vital to the development of future vehicles and computational methods for evaluating vehicle concepts. In testing at ambient conditions, IR thermography is ideal for this measurement. However, for higher Reynolds number testing, cryogenic facilities are often used, in which IR thermography is difficult to employ. In these facilities, temperature sensitive paint is an alternative with a temperature step introduced to enhance the natural temperature change from transition. Traditional methods for inducing the temperature step by changing the liquid nitrogen injection rate often change the tunnel conditions. Recent work has shown that adding a layer consisting of carbon nanotubes to the surface can be used to impart a temperature step on the model surface with little change in the operating conditions. Unfortunately, this system physically degraded at 130 K and lost heating capability. This paper describes a modification of this technique enabling operation down to at least 77 K, well below the temperature reached in cryogenic facilities. This is possible because the CNT layer is in a polyurethane binder. This was tested on a Natural Laminar Flow model in a cryogenic facility and transition detection was successfully visualized at conditions from 200 K to 110 K. Results were also compared with the traditional temperature step method.

  1. Selectively strippable paint schemes

    Science.gov (United States)

    Stein, R.; Thumm, D.; Blackford, Roger W.

    1993-03-01

    In order to meet the requirements of more environmentally acceptable paint stripping processes many different removal methods are under evaluation. These new processes can be divided into mechanical and chemical methods. ICI has developed a paint scheme with intermediate coat and fluid resistant polyurethane topcoat which can be stripped chemically in a short period of time with methylene chloride free and phenol free paint strippers.

  2. Painting for protection

    International Nuclear Information System (INIS)

    Stepto, G.G.C.

    1981-01-01

    Despite the use of special alloys, paint is still the most economical and practical method of protecting steel. Chlorinated rubber resin based paint systems are shown to be satisfactory in areas requiring decontamination as well as for outside exposed areas of nuclear power plants. (author)

  3. Terahertz thickness measurements for real industrial applications: from automotive paints to aerospace industry (Conference Presentation)

    Science.gov (United States)

    Krimi, Soufiene; Beigang, René

    2017-02-01

    In this contribution, we present a highly accurate approach for real-time thickness measurements of multilayered coatings using terahertz time domain spectroscopy in reflection geometry. The proposed approach combines the benefits of a model-based material parameters extraction method to calibrate the specimen under test, a generalized modeling method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity and the precision of the minimum thickness measurement limit. Furthermore, a novel self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the car painting process and the influence of the spraying conditions and the sintering process on ceramic thermal barrier coatings (TBCs) in aircraft industry. In addition, the developed approach enables for some applications the simultaneous determination of the complex refractive index and the coating thickness. Hence, a pre-calibration of the specimen under test is not required for such cases. Due to the high robustness of the self-calibration method and the genetic optimization algorithms, the approach has been successfully applied to resolve individual layer thicknesses within multi-layered coated samples down to less than 10 µm. The regression method can be applied in time-domain, frequency-domain or in both the time and frequency-domain simultaneously. The data evaluation uses general-purpose computing on graphics processing units and thanks to the developed highly parallelized algorithm lasts less than 300 ms. Thus, industrial requirements for fast thickness measurements with an "every-second-cycle" can be fulfilled.

  4. Radiation curable pressure sensitive adhesive composition

    International Nuclear Information System (INIS)

    Steuben, K.C.

    1978-01-01

    Radiation curable pressure sensitive adhesive composition comprises: a polyoxyalkylene homo- or copolymer which is either a polyoxyethylene homopolymer or a poly (oxyethylene-oxypropylene) copolymer, or mixture thereof, having a molecular weight of from 1,700 to 90,000, in which at least 40 percent by weight of the oxyalkylene units are oxyethylene units; a liquid carbamyloxy alkyl acrylate; and, optionally, a photoinitiator

  5. Flexible Piezoelectric-Induced Pressure Sensors for Static Measurements Based on Nanowires/Graphene Heterostructures.

    Science.gov (United States)

    Chen, Zefeng; Wang, Zhao; Li, Xinming; Lin, Yuxuan; Luo, Ningqi; Long, Mingzhu; Zhao, Ni; Xu, Jian-Bin

    2017-05-23

    The piezoelectric effect is widely applied in pressure sensors for the detection of dynamic signals. However, these piezoelectric-induced pressure sensors have challenges in measuring static signals that are based on the transient flow of electrons in an external load as driven by the piezopotential arisen from dynamic stress. Here, we present a pressure sensor with nanowires/graphene heterostructures for static measurements based on the synergistic mechanisms between strain-induced polarization charges in piezoelectric nanowires and the caused change of carrier scattering in graphene. Compared to the conventional piezoelectric nanowire or graphene pressure sensors, this sensor is capable of measuring static pressures with a sensitivity of up to 9.4 × 10 -3 kPa -1 and a fast response time down to 5-7 ms. This demonstration of pressure sensors shows great potential in the applications of electronic skin and wearable devices.

  6. Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak

    International Nuclear Information System (INIS)

    Dauber, I.M.; Pluss, W.T.; VanGrondelle, A.; Trow, R.S.; Weil, J.V.

    1985-01-01

    Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. The authors tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin ( 131 I) and erythrocytes (/sup 99m/Tc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. They calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability the authors normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. They measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity hydrostatic and high-dose thiourea edema were compared. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 x 10-4 vs. 7.6 +/- 0.9 x 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 x 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity the authors compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water

  7. Optimization of Robotic Spray Painting process Parameters using Taguchi Method

    Science.gov (United States)

    Chidhambara, K. V.; Latha Shankar, B.; Vijaykumar

    2018-02-01

    Automated spray painting process is gaining interest in industry and research recently due to extensive application of spray painting in automobile industries. Automating spray painting process has advantages of improved quality, productivity, reduced labor, clean environment and particularly cost effectiveness. This study investigates the performance characteristics of an industrial robot Fanuc 250ib for an automated painting process using statistical tool Taguchi’s Design of Experiment technique. The experiment is designed using Taguchi’s L25 orthogonal array by considering three factors and five levels for each factor. The objective of this work is to explore the major control parameters and to optimize the same for the improved quality of the paint coating measured in terms of Dry Film thickness(DFT), which also results in reduced rejection. Further Analysis of Variance (ANOVA) is performed to know the influence of individual factors on DFT. It is observed that shaping air and paint flow are the most influencing parameters. Multiple regression model is formulated for estimating predicted values of DFT. Confirmation test is then conducted and comparison results show that error is within acceptable level.

  8. Measurement of pressure on a surface using bubble acoustic resonances

    International Nuclear Information System (INIS)

    Aldham, Ben; Manasseh, Richard; Liffman, Kurt; Šutalo, Ilija D; Illesinghe, Suhith; Ooi, Andrew

    2010-01-01

    The frequency response of gas bubbles as a function of liquid ambient pressure was measured and compared with theory. A bubble size with equivalent spherical radius of 2.29 mm was used over a frequency range of 1000–1500 Hz. The ultimate aim is to develop an acoustic sensor that can measure static pressure and is sensitive to variations as small as a few kPa. The classical bubble resonance frequency is known to vary with ambient pressure. Experiments were conducted with a driven bubble in a pressurizable tank with a signal processing system designed to extract the resonant peak. Since the background response of the containing tank is significant, particularly near tank-modal resonances, it must be carefully removed from the bubble response signal. A dual-hydrophone method was developed to allow rapid and reliable real-time measurements. The expected pressure dependence was found. In order to obtain a reasonable match with theory, the classical theory was modified by the introduction of a 'mirror bubble' to account for the influence of a nearby surface. (technical design note)

  9. Accelerated bridge paint test program.

    Science.gov (United States)

    2011-07-06

    The accelerated bridge paint (AB-Paint) program evaluated a new Sherwin-Williams two-coat, : fast-curing paint system. The system is comprised of an organic zinc-rich primer (SW Corothane I : Galvapac One-Pack Zinc-Rich Primer B65 G11) and a polyurea...

  10. Structuralist readings: Painting vs. picture

    Directory of Open Access Journals (Sweden)

    Marinkov-Pavlović Lidija

    2016-01-01

    Full Text Available The aim of the paper is to point to two fundamentally different strategies of painting practice, that is, to two subsystems of painting: picture and painting. This differentiation can be made within the framework of semiotic and semiological analyses which have developed in theory under the influence of structuralism. The first part of the paper offers a basic insight into the linguistic foundation of structuralistic concept, and then sets a thesis about the possibility of analogue reconceptualisation of semiotics/semiology of painting through Julia Kristeva's semiotics and Roland Barthes' semiology. In addition, it points to the concrete concepts of structural analysis which have accentuated the opposition picture-painting with the examples of art practice concurrent to the development of structuralism. However, what is revealed is that various structuralist readings are significantly subjective to unstable relationship between the basic elements in the pictorial object, that is, in the work of painting.

  11. Fiber Bragg Grating Sensor to Monitor Stress Kinetics in Drying Process of Commercial Latex Paints

    Directory of Open Access Journals (Sweden)

    Ivo de Lourenço

    2010-05-01

    Full Text Available In this paper, we report a study about the application of packaged fiber Bragg gratings used as strain sensors to monitor the stress kinetics during the drying process of commercial latex paints. Three stages of drying with distinct mechanical deformation and temporal behaviors were identified for the samples, with mechanical deformation from 15 μm to 21 μm in the longitudinal film dimension on time intervals from 370 to 600 minutes. Drying time tests based on human sense technique described by the Brazilian Technical Standards NBR 9558 were also done. The results obtained shows that human sense technique has a limited perception of the drying process and that the optical measurement system proposed can be used to characterize correctly the dry-through stage of paint. The influence of solvent (water addition in the drying process was also investigated. The paint was diluted with four parts paint and one part water (80% paint, and one part paint and one part water (50% paint. It was observed that the increase of the water ratio mixed into the paint decreases both the mechanical deformation magnitude and the paint dry-through time. Contraction of 5.2 μm and 10.4 μm were measured for concentrations of 50% and 80% of paint in the mixture, respectively. For both diluted paints the dry-through time was approximately 170 minutes less than undiluted paint. The optical technique proposed in this work can contribute to the development of new standards to specify the drying time of paint coatings.

  12. Surface-enhanced Raman spectroscopy studies of yellow organic dyestuffs and lake pigments in oil paint.

    Science.gov (United States)

    Mayhew, Hannah E; Fabian, David M; Svoboda, Shelley A; Wustholz, Kristin L

    2013-08-21

    Identifying natural, organic dyes and pigments is important for the conservation, preservation, and historical interpretation of works of art. Although previous SERS studies have demonstrated high sensitivity and selectivity for red lake pigments using various pretreatment conditions, corresponding investigations of yellow lake pigments and paints are relatively sparse. Here, surface-enhanced Raman scattering (SERS) spectroscopy is used to identify a variety of yellow organic dyestuffs and lake pigments in oil paint. High-quality SERS spectra of yellow dyestuffs (i.e., turmeric, old fustic, Buckthorn berries) and corresponding paints could be obtained with or without sample pretreatment using microliter quantities of HCl and methanol at room temperature. However, the SERS spectra of yellow lake pigments (i.e., Stil de Grain, Reseda lake) and their corresponding oil paints were only observed upon sample pretreatment. Ultimately, we demonstrate a reliable sample treatment protocol for SERS-based identification of turmeric, old fustic, Buckthorn berries, Stil de Grain, and Reseda lake as well as for microscopic samples of the corresponding oil paints.

  13. Ultrasonic backward radiation on painted rough interface

    International Nuclear Information System (INIS)

    Kwon, Yong Gyu; Yoon, Seok Soo; Kwon, Sung Duck

    2002-01-01

    The angular dependence(profile) of backscattered ultrasound was measured for steel and brass specimens with periodical surface roughness (1-71μm). Backward radiations showed more linear dependency than normal profile. Direct amplitude increased and averaging amplitude decreased with surface roughness. Painting treatment improved the linearity in direct backward radiation below roughness of 0.03. Scholte and Rayleigh-like waves were observed in the spectrum of averaging backward radiation on periodically rough surface. Painting on periodically rough surface could be used in removing the interface mode effect by periodic roughness.

  14. Falls event detection using triaxial accelerometry and barometric pressure measurement.

    Science.gov (United States)

    Bianchi, Federico; Redmond, Stephen J; Narayanan, Michael R; Cerutti, Sergio; Celler, Branko G; Lovell, Nigel H

    2009-01-01

    A falls detection system, employing a Bluetooth-based wearable device, containing a triaxial accelerometer and a barometric pressure sensor, is described. The aim of this study is to evaluate the use of barometric pressure measurement, as a surrogate measure of altitude, to augment previously reported accelerometry-based falls detection algorithms. The accelerometry and barometric pressure signals obtained from the waist-mounted device are analyzed by a signal processing and classification algorithm to discriminate falls from activities of daily living. This falls detection algorithm has been compared to two existing algorithms which utilize accelerometry signals alone. A set of laboratory-based simulated falls, along with other tasks associated with activities of daily living (16 tests) were performed by 15 healthy volunteers (9 male and 6 female; age: 23.7 +/- 2.9 years; height: 1.74 +/- 0.11 m). The algorithm incorporating pressure information detected falls with the highest sensitivity (97.8%) and the highest specificity (96.7%).

  15. Pressure Sensitive Sensors Based on Carbon Nanotubes, Graphene, and Its Composites

    Directory of Open Access Journals (Sweden)

    Asar Ali

    2018-01-01

    Full Text Available Carbon nanotubes (CNTs and graphene have attracted a great deal of interest due to their outstanding mechanical, optical, electrical, and structural properties. Most of the scientists and researchers have investigated the optical and electrical properties of these materials. However, due to unique electromechanical properties of these materials, it is required to explore the piezoresistive properties of bulk nanostructured CNTs, graphene, and CNT-graphene composites. We investigated and compared the sensitivities and piezoresistive properties of sandwich-type pure CNT, pure graphene, and CNT-graphene composite pressure sensors. For all the samples, increase in pressure from 0 to 0.183 kNm−2 results in a decrease in the impedance and direct current (DC resistance. Sensitivity and percentage decrease in resistance and impedance of CNT-graphene composite were lower than pure CNT while being higher than pure graphene based sample. Moreover, under the same external applied pressure, the sensitivity and percentage decrease in impedance for pure CNT, pure graphene, and CNT-graphene composite were smaller than the corresponding sensitivity and percentage decrease in resistance. The achieved experimental results of the composite sample were compared with simulated results which exhibit reasonable agreement with each other. The deviations of simulated resistance-pressure and impedance-pressure curves from experimental graphs were 0.029% and 0.105%, respectively.

  16. Direct Printing of Stretchable Elastomers for Highly Sensitive Capillary Pressure Sensors.

    Science.gov (United States)

    Liu, Wenguang; Yan, Chaoyi

    2018-03-28

    We demonstrate the successful fabrication of highly sensitive capillary pressure sensors using an innovative 3D printing method. Unlike conventional capacitive pressure sensors where the capacitance changes were due to the pressure-induced interspace variations between the parallel plate electrodes, in our capillary sensors the capacitance was determined by the extrusion and extraction of liquid medium and consequent changes of dielectric constants. Significant pressure sensitivity advances up to 547.9 KPa -1 were achieved. Moreover, we suggest that our innovative capillary pressure sensors can adopt a wide range of liquid mediums, such as ethanol, deionized water, and their mixtures. The devices also showed stable performances upon repeated pressing cycles. The direct and versatile printing method combined with the significant performance advances are expected to find important applications in future stretchable and wearable electronics.

  17. Prediction of optical properties of paints

    Science.gov (United States)

    Ďurikovič, Roman; Ágošton, Tomaš

    2007-09-01

    The field of predictive rendering concerns itself with those methods of image synthesis which yield results that do not only look real, but are also radiometrically correct renditions of nature, i.e., which are accurate predictions of what a real scene would look like under given lighting conditions. A real coating consists of pigments, effect pigments, clear lacquer and glaze. A novel and unique combination of real parameters that are commonly measured in the industry and a theoretical reflectance model consisting of measurable parameters is required. Here, the authors design perception parameters and put them into well known surface reflection functions such as He and Torrance. The original contributions are the study of the sub-surface scattering of real paint and the prediction of its appearance in rendered images by the proposed model of light reflection beneath the paint surface.

  18. Methylisothiazolinone and benzisothiazolinone are widely used in paint: a multicentre study of paints from five European countries

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Lundov, Michael; Bossi, Rossana

    2015-01-01

    were found in paints from all five countries. Paints purchased in Denmark and Sweden contained especially high concentrations of BIT. CONCLUSION: The use of MI across European countries is extensive. In view of the ongoing epidemic of MI contact allergy, an evaluation of the safety of MI in paints......BACKGROUND: In view of the current epidemic of contact allergy to methylisothiazolinone (MI), it is important to clarify the extent of use of MI and related isothiazolinones in paints currently available for the consumer and worker in Europe. OBJECTIVES: To elucidate the use and concentrations...... of MI, methylchloroisothiazolinone (MCI) and benzisothiazolinone (BIT) in paints on the European retail market. METHODS: Wall paints (n = 71) were randomly purchased in retail outlets in five European countries. The paints were quantitatively analysed for their contents of MI, MCI and BIT by high...

  19. Paintings - high-energy protons detect pigments and paint-layers

    International Nuclear Information System (INIS)

    Denker, A.; Opitz-Coutureau, J.

    2004-01-01

    High-energy PIXE was used to identify pigment composition, sequencing and the thickness of paint-layers. Before applying the technique to valuable masterpieces, mock-ups were examined in a collaboration with the Kunsthistorisches Museum, Vienna. The results of high-energy PIXE were compared to conventional cross-section analysis. In addition, the non-destructiveness of the technique was investigated thoroughly. After this preparative work, two ancient paintings have been examined and the results are presented in this paper

  20. Thermal imaging method to visualize a hidden painting thermally excited by far infrared radiations

    Science.gov (United States)

    Davin, T.; Wang, X.; Chabane, A.; Pawelko, R.; Guida, G.; Serio, B.; Hervé, P.

    2015-06-01

    The diagnosis of hidden painting is a major issue for cultural heritage. In this paper, a non-destructive active infrared thermographic technique was considered to reveal paintings covered by a lime layer. An extended infrared spectral range radiation was used as the excitation source. The external long wave infrared energy source delivered to the surface is then propagated through the material until it encounters a painting zone. Due to several thermal effects, the sample surface then presents non-uniformity patterns. Using a high sensitive infrared camera, the presence of covered pigments can thus be highlighted by the analysis of the non-stationary phenomena. Reconstituted thermal contrast images of mural samples covered by a lime layer are shown.

  1. Historical origins of Petrykivsky decorative painting

    Directory of Open Access Journals (Sweden)

    T. A. Harkava

    2017-07-01

    Full Text Available Petrykivsky decorative painting is a part of Ukrainian folk art. Domestic science of folk art has originated and has been developing primarily as a study of archaeological antiquities and artistic monuments of the past. Scientific papers, which comprehended the process of folk art development, began to appear in the late nineteenth century, Archaeological Congresses became the impetus for their appearance. Being a representative of the decorative painting, Petrikivsky decorative painting is rooted by its murals to Tripoli. It was created as a peasant domestic drawing. Inexhaustible diversity of local variants of Petrikivsky decorative painting, its evolutionary change, the individual characteristics of paintings of hundreds of famous Ukrainian artists do not even allow comparing it to any other European counterparts, each of which is characterized only by some individual techniques. Petrikivsky decorative painting got the significant boost in its distribution and development when it «came down» from walls to paper. Paper pictures - malyovky - were stucked to walls following the traditional rules of domestic interior’s decoration. Petrikivsky decorative painting got the official status in 1913, when E. Evenbah, by the initiative of D.I. Yavornytsky, gathered the collection of Petrikivsky decorative painting’s malyovkas and organized the exhibition in St. Petersburg. Motives of painting are rooted into the local flora and fauna and into the historical tradition. However, Petrikivsky decorative painting is not a direct reflection of natural motifs. World, created in paintings, is the product of the imagination of folk artist, it is the stylization of local flowers, fruits and birds. First names of Masters of Petrikivsky decorative painting, which appeared in historical sources, were T. Pata, N. Bilokin, I. Pavlenko. Their official recognition happened in 1930 after their participation in the first republican exhibition, which was later shown

  2. The Effect of Daily Self-Measurement of Pressure Pain Sensitivity Followed by Acupressure on Depression and Quality of Life versus Treatment as Usual in Ischemic Heart Disease

    DEFF Research Database (Denmark)

    Bergmann, Natasha; Ballegaard, Søren; Bech, Per

    2014-01-01

    -measurement of PPS twice daily followed by acupressure as mandatory action, aiming at a reduction in PPS. Primary endpoint: change in depressive symptoms as measured by Major depression inventory (MDI). Other endpoints: changes in PPS, Well-being (WHO-5) and mental and physical QOL (SF-36). RESULTS: At 3 months PPS......BACKGROUND: Depressive symptoms and reduced quality of life (QOL) are parts of the chronic stress syndrome and predictive of adverse outcome in patients with ischemic heart disease (IHD). Chronic stress is associated with increased sensitivity for pain, which can be measured by algometry...... as Pressure Pain Sensitivity (PPS) on the sternum. AIM: To evaluate if stress focus by self-measurement of PPS, followed by stress reducing actions including acupressure, can decrease depressive symptoms and increase psychological well-being in people with stable IHD. DESIGN: Observer blinded randomized...

  3. Radiation safety in radioluminous paint workshop handling tritium activated paint

    International Nuclear Information System (INIS)

    Gaur, P.K.; Venkateswaran, T.V.

    1986-01-01

    This paper discusses the safety features related to a workshop when tritium activated luminous paint is handled by workmen. Salient features of the workshop and the methods employed for monitoring the radiation levels are briefly outlined and results are discussed. The importance of proper ventilation of the workplace and precautions to be taken in the storage of painted articles are highlighted. (author). 1 table, 3 figs

  4. Superconducting Accelerating Cavity Pressure Sensitivity Analysis

    International Nuclear Information System (INIS)

    Rodnizki, J.; Horvits, Z.; Ben Aliz, Y.; Grin, A.; Weissman, L.

    2014-01-01

    The measured sensitivity of the cavity was evaluated and it is full consistent with the measured values. It was explored that the tuning system (the fog structure) has a significant contribution to the cavity sensitivity. By using ribs or by modifying the rigidity of the fog we may reduce the HWR sensitivity. During cool down and warming up we have to analyze the stresses on the HWR to avoid plastic deformation to the HWR since the Niobium yield is an order of magnitude lower in room temperature

  5. Design and Application of a High Sensitivity Piezoresistive Pressure Sensor for Low Pressure Conditions

    Science.gov (United States)

    Yu, Huiyang; Huang, Jianqiu

    2015-01-01

    In this paper, a pressure sensor for low pressure detection (0.5 kPa–40 kPa) is proposed. In one structure (No. 1), the silicon membrane is partly etched to form a crossed beam on its top for stress concentration. An aluminum layer is also deposited as part of the beam. Four piezoresistors are fabricated. Two are located at the two ends of the beam. The other two are located at the membrane periphery. Four piezoresistors connect into a Wheatstone bridge. To demonstrate the stress concentrate effect of this structure, two other structures were designed and fabricated. One is a flat membrane structure (No. 2), the other is a structure with the aluminum beam, but without etched silicon (No. 3). The measurement results of these three structures show that the No.1 structure has the highest sensitivity, which is about 3.8 times that of the No. 2 structure and 2.7 times that of the No. 3 structure. They also show that the residual stress in the beam has some backside effect on the sensor performance. PMID:26371001

  6. [Occupational exposure to hexavalent chromium during aircraft painting].

    Science.gov (United States)

    Gherardi, M; Gatto, M P; Gordiani, A; Paci, E; Proietto, A

    2007-01-01

    Hygienists are interested in hexavalent chromium due to its genotoxic and carcinogenic effect on humans. The use of products containing hexavalent chromium is decreasing in many industrial fields because of the substitution with less-toxic compounds. In the aeronautical industry, however, the chromate are added to primer paint as a corrosion inhibitor of aircrafts surfaces: so hexavalent chromium compounds are available in many primers with a composition ranging from 10% to 13%. The application of these primers by using electrostatic guns potentially exposes painting and coating workers at high concentrations of aerosols containing Cr(VI). The aim of the present study is the evaluation of professional exposure to hexavalent chromium during aircraft painting, by adopting both environmental personal sampling and biological monitoring. To valuate workers exposure levels the personal measurements results have been compared with the exposure limit values (TLV-TWA) and the urinary chromium contents with the biological exposure indices (IBE). Moreover the strategy of coupling environmental sampling with biological monitoring seems to be a useful instrument to measure the validity of the individual protection devices.

  7. Polymeric reaction of polymer-monomer system for pressure sensitive adhesives by low energy electron beam

    International Nuclear Information System (INIS)

    Takiguchi, R.; Uryu, T.

    1985-01-01

    Application of low-energy electron beam to non-solvent type pressure sensitive adhesives is investigated. The adhesive properties such as peel strength and holding time (dead-load strength) were closely related to the reaction of acrylate polymer-monomer systems. The reaction behavior is elucidated by combining the measurement of gel fraction, infrared spectrum of gel, and the molecular weight distribution detected by gel permeation chromatography. It was important for the production of pressure sensitive adhesives by electron beam that the adhesive with high peel strength and long holding time is composed of a proper combination of three factors, that is, about 35% gel fraction, 25% monomer units in gel, and 15% graft efficiency by irradiating the polymer-monomer system containing low molecular weight poly (butyl acrylate). (author)

  8. Smart paint sensor for monitoring structural vibrations

    International Nuclear Information System (INIS)

    Al-Saffar, Y; Baz, A; Aldraihem, O

    2012-01-01

    A class of smart paint sensors is proposed for monitoring the structural vibration of beams. The sensor is manufactured from an epoxy resin which is mixed with carbon black nano-particles to make it electrically conducting and sensitive to mechanical vibrations. A comprehensive theoretical and experimental investigation is presented to understand the underlying phenomena governing the operation of this class of paint sensors and evaluate its performance characteristics. A theoretical model is presented to model the electromechanical behavior of the sensor system using molecular theory. The model is integrated with an amplifier circuit in order to predict the current and voltage developed by the paint sensor when subjected to loading. Furthermore, the sensor/amplifier circuit models are coupled with a finite element model of a base beam to which the sensor is bonded. The resulting multi-field model is utilized to predict the behavior of both the sensor and the beam when subjected to a wide variety of vibration excitations. The predictions of the multi-field finite element model are validated experimentally and the behavior of the sensor is evaluated both in the time and the frequency domains. The performance of the sensor is compared with the performance of conventional strain gages to emphasize its potential and merits. The presented techniques are currently being extended to sensors that can monitor the vibration and structural power flow of two-dimensional structures. (paper)

  9. Diaphragm size and sensitivity for fiber optic pressure sensors

    Science.gov (United States)

    He, Gang; Cuomo, Frank W.; Zuckerwar, Allan J.

    1991-01-01

    A mechanism which leads to a significant increase in sensitivity and linear operating range in reflective type fiber optic pressure transducers with minute active dimensions is studied. A general theoretical formalism is presented which is in good agreement with the experimental data. These results are found useful in the development of small pressure sensors used in turbulent boundary layer studies and other applications.

  10. Photogrammetry Applied to Wind Tunnel Testing

    Science.gov (United States)

    Liu, Tian-Shu; Cattafesta, L. N., III; Radeztsky, R. H.; Burner, A. W.

    2000-01-01

    In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

  11. En-bloc excision debridement of spray paint injection injury to the ...

    African Journals Online (AJOL)

    Background: High pressure injection injuries to the hand are relatively uncommon. The potential and actual tissue injuries are often underestimated by the primary care giver. Patient: This is a report on a 27 year old dock worker who sustained a spray paint gun injury to the left hand with resulting digital neurovascular ...

  12. Microscopy and the Mystery of Pablo Picasso's Paints

    Science.gov (United States)

    Rose, Volker

    A deep connection to our past and shared cultural heritage must be preserved to foster a balanced society where all humanity can thrive. This talk will describe analysis of paint materials used by Pablo Picasso at the nanoscale, as only possible at the brightest synchrotron sources. It will highlight how new imaging techniques can reveal the invisible, bringing to light underlying compositions of old masters' paintings. This in turn enables the writing of new art history and provides important material clues that can assist with attribution and authentication. We will explain how the use of new technology can lead to new discoveries, which, in turn, can change the public's and the specialists' perception of great works of art. ∖In collaboration with scientists from The Art Institute of Chicago we have teamed up to study the chemical make up of zinc oxide pigments used in artworks by Pablo Picasso. We will show how highly focused X-ray beams with nanoscale spatial resolution and trace element sensitivity have helped to determine that Picasso has used conventional house paint in some of his paintings. Surprisingly, the study gives also new insights into the pigment material zinc oxide, which has also great potential in a variety of applications such as in spintronics or as transparent electrodes in solar panels. Work at the Advanced Photon Source and the Center for Nanoscale Materials was supported by the U. S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under contract DEAC02-06CH11357.

  13. Emission of Isothiazolinones from Water-Based Paints

    DEFF Research Database (Denmark)

    Lundov, Michael D; Kolarik, Barbara; Bossi, Rossana

    2014-01-01

    were measured in climate chambers and in an apartment. Nineteen paints were analyzed for the content of MI, MCI, and BIT. All 19 paints contained MI, 16 contained BIT, and 4 contained MCI. In the chamber experiment emission of MI peaked within hours of application but then continued at a slow rate...... for more than 42 days. MCI was emitted more slowly and peaked after several days. BIT emissions were all around the limit of detection. In the apartment we were able to detect emission of MI several days after application. Long lasting evaporation and thus chronic exposure give credibility to the clinical...

  14. Dissolution rate measurements of sea water soluble pigments for antifouling paints

    DEFF Research Database (Denmark)

    Yebra, Diego Meseguer; Kiil, Søren; Erik Weinell, Claus

    2006-01-01

    The dissolution of soluble pigments from both tin-based and tin-free chemically active antifouling (AF) paints is a key process influencing their polishing and biocide leaching rates. In this context, a low time- and resources-consuming method capable of screening the pigment behaviour in the sea...

  15. Impact on the environment from steel bridge paint deterioration using lead isotopic tracing, paint compositions and soil deconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Department of Environmental Science, Macquarie University, Sydney, NSW 2109 (Australia); CSIRO Energy Flagship, North Ryde, NSW 2113 (Australia); Chiaradia, Massimo [Department of Mineralogy, University of Geneva, Geneva (Switzerland); Davis, Jeffrey [CSIRO Energy Flagship, North Ryde, NSW 2113 (Australia); O' Connor, Gary [Queensland Department of Environment & Heritage Protection, Brisbane, QLD 4000 (Australia)

    2016-04-15

    Deterioration and repair of lead paint on steel structures can result in contamination of the ambient environment but other sources of lead such as from past use of leaded paint and gasoline and industrial activities can also contribute to the contamination. Using a combination of high precision lead isotopic tracing, detailed paint examination, including with scanning electron microscopy, and soil deconstruction we have compared paint on a steel bridge and bulk soil and lead-rich particles separated from soil. The majority of Pb found in the paint derives from Australian sources but some also has a probable US origin. The isotopic data for the bulk soils and selected particles lie on a mixing line with end members the geologically ancient Broken Hill lead and possible European lead which is suggested to be derived from old lead paint and industrial activities. Data for gasoline-derived particulates lie on this array and probably contribute to soil Pb. Although paint from the bridge can be a source of lead in the soils, isotopic tracing, paint morphology and mineralogical identification indicate that other sources, including from paint, gasoline and industrial activities, are contributing factors to the lead burden. Even though physical characteristics and elemental composition are the same in some particles, the isotopic signatures demonstrate that the sources are different. Plots using {sup 206}Pb/{sup 208}Pb vs {sup 206}Pb/{sup 207}Pb ratios, the common representation these days, do not allow for source discrimination in this investigation. - Highlights: • Soil Pb values up to 1200 mg/kg below Pb painted bridge • Microscopy & SEM characterised up to 6 different paint layers. • Isotopes identified different sources of Pb including paint and gasoline. • Multiple methods provide definitive answers.

  16. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and reevaluations. 35.1320 Section 35.1320 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT...

  17. 75 FR 6383 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Science.gov (United States)

    2010-02-09

    ..., Repair and Painting, and Pre- Renovation Education Activities in Target Housing and Child Occupied....C. 2682(c)(3), and a lead-based paint pre-renovation education program in accordance with section... TSCA, and a lead-based paint pre-renovation education program in accordance with section 406(b) of TSCA...

  18. Fluorescence from colours used for japanese painting under N_2 laser excitation

    OpenAIRE

    Miyoshi, Tadaki

    1988-01-01

    The fluorescence spectra have been measured for various colours used for Japanese painting in order to identify the pigments in paintings. Fluorescence was observed in various natural and synthetic colours. The fluorescence intensities of these colours are generally weaker than those of oil colours.

  19. Pressure Sensitive Device Using Conductive and Porous Structures

    International Nuclear Information System (INIS)

    So, Hye-Mi; Chang, Won Seok; Park, Cheolmin

    2014-01-01

    Porous conductors are known to demonstrate excellent electrical, mechanical, and chemical resistance. These porous conductors demonstrated potential applications in various fields such as electrodes for supercapacitors, flexible heaters, catalytic electrodes, and sorbents. In this study, we described a pressure sensitive device using conductive and porous sponges. With an extremely simple “dipping and drying” process using a single-walled carbon nanotube (SWCNT) solution, we produced conductive sponges with sheet resistance of < 30 kΩ/sq. These carbon nanotube sponges can be deformed into any shape elastically and repeatedly compressed to large strains without collapse. The pressure sensors developed from these sponges demonstrated high resistance change under pressure of up to a half of their initial resistance

  20. Pressure Sensitive Device Using Conductive and Porous Structures

    Energy Technology Data Exchange (ETDEWEB)

    So, Hye-Mi; Chang, Won Seok [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of); Park, Cheolmin [University of Science and Technology, Daejeon (Korea, Republic of)

    2014-07-15

    Porous conductors are known to demonstrate excellent electrical, mechanical, and chemical resistance. These porous conductors demonstrated potential applications in various fields such as electrodes for supercapacitors, flexible heaters, catalytic electrodes, and sorbents. In this study, we described a pressure sensitive device using conductive and porous sponges. With an extremely simple “dipping and drying” process using a single-walled carbon nanotube (SWCNT) solution, we produced conductive sponges with sheet resistance of < 30 kΩ/sq. These carbon nanotube sponges can be deformed into any shape elastically and repeatedly compressed to large strains without collapse. The pressure sensors developed from these sponges demonstrated high resistance change under pressure of up to a half of their initial resistance.

  1. PAINT SUPPLIES AND LOCATION: EXAMINING ICI

    Directory of Open Access Journals (Sweden)

    M. Herron

    2016-01-01

    Full Text Available How important is location to an international retailer? Not just any retailer but the second largest paint retailer in the world. Imperial Chemical Industries (ICI was a British chemical company and was at one stage the largest manufacturer in Britain. Formed from the merger of several leading British chemical companies in 1926, ICI makes paints and speciality products, including food ingredients, speciality polymers, electronic materials, fragrances and flavourings. ICI paints purchased the Cleveland Ohiobased Glidden Coatings & Resins (Glidden Paint Company in 1986 for USD$580 million. The addition of Glidden to ICI's North American operations more than doubled that subsidiary's annual sales to $3 billion and increased ICI's corporate presence in the United States dramatically. A decline in paint and solvent consumption during the 2000 decade slowed the average growth of the paint industry to about 2% annually. Rauch Associates, the leading US paint analyst firm, predicted near-term growth to slow even further to 1.2% per annum. Through the 1990’s and early 2000’s Glidden paint was sold only through Glidden-badged paint stores and smaller retailers under licence, developing a strong identifiable brand and reputation. How were potential Glidden retail paint store locations chosen across America to enable and support this market growth? This paper investigates the real process that was developed and applied to construct a national network of retail outlets across the United States. It also highlights the change in direction that occurred at ICI paints culminating in its eventual acquisition by AkzoNobel in 2008 who immediately sold parts of ICI to Henkel, and integrated ICI's remaining operations within its existing organisation. This sale and the associated corporate restructure caused considerable change in marketing directions allowing for the first time the selling of Glidden paint products to mass market centres

  2. The Effect of Micrite on Velocity, Its Sensitivity to Pressure, and Dissolution of Carbonates

    Science.gov (United States)

    El Husseiny, A.; Vanorio, T.

    2014-12-01

    This study investigates the effect of micrite on the acoustic properties of well-controlled microstructures created in the laboratory to closely mimic carbonate rocks. In particular, we examine the effect of micrite content on the elastic stiffness rock, its sensitivity to pressure, and induced dissolution upon saturation with a reactive fluid. We followed Dunham's classification and fabricated the samples by mixing coarse (sand size) and very fine (micrite size) calcite grains in different ratios, with the addition of cement and then cold-compressing the mixture. The acoustic velocities were measured under bench-top conditions and as functions of confining pressure before and after the injection of a CO2aqueous solution. Our bench-top measurements indicated that micrite makes the frame of the carbonate samples stiffer. Since the sensitivity of the elastic stiffness to pressure decreases as the content of micrite increases (see figure 1), we hypothesize a stiffer pore structure (i.e., rounder pores) in micrite-richer fabrics. Furthermore, the presence of micrite makes the carbonate sample more reactive upon dissolution. The concentration of Ca+2 cations in the fluid measured at the outlet after the injection of the CO2 aqueous solution shows larger dissolution in the micrite-rich samples likely due to the higher surface area of the micrite aggregates. The content of micrite also seems to affect the evolution of stiffness as dissolution proceeds. As the content of micrite increases, the enhanced dissolution translates into a marked softening of the rock frame. We conclude that the content of micrite can play an important role in the complex rock-fluid interaction of carbonates as well as when comparing Gassmann's predictions to velocity measurements of saturated carbonates.

  3. Radiation polymerized hot melt pressure sensitive adhesives

    International Nuclear Information System (INIS)

    Pastor, S.D.; Skoultchi, M.M.

    1977-01-01

    Hot melt pressure sensitive adhesive compositions formed by copolymerizing at least one 3-(chlorinated aryloxy)-2-hydroxypropyl ester of an alpha, beta unsaturated carboxylic acid with acrylate based copolymerizable monomers, are described. The resultant ethylenically saturated prepolymer is heated to a temperature sufficient to render it fluid and flowable. This composition is coated onto a substrate and exposed to ultraviolet radiation

  4. Chromosome painting in plants.

    NARCIS (Netherlands)

    Schubert, I.; Fransz, P.F.; Fuchs, J.; Jong, de J.H.

    2001-01-01

    The current 'state-of-art' as to chromosome painting in plants is reviewed. We define different situations described as painting so far: i) Genomic in situ hybridisation (GISH) with total genomic DNA to distinguish alien chromosomes on the basis of divergent dispersed repeats, ii) 'Chromosomal in

  5. Painting rusted steel: The role of aluminum phosphosilicate

    International Nuclear Information System (INIS)

    Roselli, S.N.; Amo, B. del; Carbonari, R.O.; Di Sarli, A.R.; Romagnoli, R.

    2013-01-01

    Highlights: •Aluminum phosphosilicate is an acid pigment which could act as mild phosphating agent. •Aluminum phosphosilicate can phosphatize iron oxides on rusted surfaces. •Aluminum phosphosilicate is compatible with acid binders. •Aluminum phosphosilicate could replace chromate in complete painting schemes. •Aluminum phosphosilicate primers improve paints adhesion on rusted surfaces. -- Abstract: Surface preparation is a key factor for the adequate performance of a paint system. The aim of this investigation is to employ a wash-primer to accomplish the chemical conversion of rusted surface when current cleaning operations are difficult to carry out. The active component of the wash-primer was aluminum phosphosilicate whose electrochemical behavior and the composition of the generated protective layer, both, were studied by electrochemical techniques and scanning electron microscopy (SEM), respectively. Primed rusted steel panels were coated with an alkyd system to perform accelerated tests in the salt spray chamber and electrochemical impedance measurements (EIS). These tests were conducted in parallel with a chromate wash primer and the same alkyd system. Results showed that the wash-primer containing aluminum phosphosilicate could be used satisfactorily to paint rusted steel exhibiting a similar performance to the chromate primer

  6. Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt

    DEFF Research Database (Denmark)

    Højgaard, Michael V; Agner, Erik; Kanters, Jørgen K

    2005-01-01

    OBJECTIVE: Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS: We measured normal-to-normal heart beat...... pressures were extracted for the assessment of day-to-day and short-term reproducibility. Power spectrum analysis (Fourier) and transfer function analysis was performed. Reproducibility was assessed using the coefficient of variation (CV). The reproducibility of the mean RR interval, mean systolic......, diastolic and mean blood pressure was good (CVspectral parameters of HRV (CV range 18-36%) and BPV (16-44%) and moderate reproducibility of BRS (14-20%). CONCLUSION: Spectral estimates of BRS had only moderate reproducibility although...

  7. Beauty in abstract paintings: Perceptual contrast and statistical properties

    Directory of Open Access Journals (Sweden)

    Birgit eMallon

    2014-03-01

    Full Text Available In this study, we combined the behavioral and objective approach in the field of empirical aesthetics. First, we studied the perception of beauty by investigating shifts in evaluation on perceived beauty of abstract artworks (Experiment 1. Because the participants showed heterogeneous individual preferences for the paintings, we divided them into seven clusters for the test. The experiment revealed a clear pattern of perceptual contrast. The perceived beauty of abstract paintings increased after exposure to paintings that were rated as less beautiful, and it decreased after exposure to paintings that were rated as more beautiful. Next, we searched for correlations of beauty ratings and perceptual contrast with statistical properties of abstract artworks (Experiment 2. The participants showed significant preferences for certain image properties. These preferences differed between the clusters of participants. Strikingly, next to color measures like hue, saturation, value and lightness, the recently described PHOG self-similarity value seems to be a predictor for aesthetic appreciation of abstract artworks. We speculate that the shift in evaluation in Experiment 1 was, at least in part, based on low-level adaptation to some of the statistical image properties analyzed in Experiment 2. In conclusion, our findings demonstrate that the perception of beauty in abstract artworks is altered after exposure to beautiful or non-beautiful images and correlates with particular image properties, especially color measures and self-similarity.

  8. External beam PIXE analysis of painting

    International Nuclear Information System (INIS)

    Pascholati, Paulo R.; Rizzutto, Marcia A.; Barbosa, Marcel D.L.; Albuquerque, Cindy

    2005-01-01

    The preservation and conservation of mankind cultural heritage has become an important issue worldwide. Non-destructive analytical techniques are suitable, for example, to analyze precious and unique objects of art and archaeology. Among those techniques Particle Induced X-Ray Emission (PIXE) has good advantage to identify elemental composition present in these kinds of objects. The Laboratorio de Analise de Materiais por Feixes Ionicos-LAMFI of the Institute of Physics of the University of Sao Paulo has been installed an external beam facility for PIXE analysis. This new setup is being used for the analysis of archaeological pottery artifacts, paintings and biological tissues (teeth and bones), which are not compatible with the high vacuum of the regular PIXE target chamber. In addition most art and archaeological objects are too large for the evacuated analysis chamber. Applications of this facility will be presented in the analysis of one painting of the beginning of the last century. The chemical elements identified in the painting were Ca, Ti, Cr, Cu, Fe, Zn, Pb and Ba. The PIXE measurements were done non-destructively and no visible damage was observed on the irradiated object. (author)

  9. The colors of paintings and viewers' preferences.

    Science.gov (United States)

    Nascimento, Sérgio M C; Linhares, João M M; Montagner, Cristina; João, Catarina A R; Amano, Kinjiro; Alfaro, Catarina; Bailão, Ana

    2017-01-01

    One hypothesis to explain the aesthetics of paintings is that it depends on the extent to which they mimic natural image statistics. In fact, paintings and natural scenes share several statistical image regularities but the colors of paintings seem generally more biased towards red than natural scenes. Is the particular option for colors in each painting, even if less naturalistic, critical for perceived beauty? Here we show that it is. In the experiments, 50 naïve observers, unfamiliar with the 10 paintings tested, could rotate the color gamut of the paintings and select the one producing the best subjective impression. The distributions of angles obtained are described by normal distributions with maxima deviating, on average, only 7 degrees from the original gamut orientation and full width at half maximum just above the threshold to perceive a chromatic change in the paintings. Crucially, for data pooled across observers and abstract paintings the maximum of the distribution was at zero degrees, i.e., the same as the original. This demonstrates that artists know what chromatic compositions match viewers' preferences and that the option for less naturalistic colors does not constrain the aesthetic value of paintings. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Flexible hemispheric microarrays of highly pressure-sensitive sensors based on breath figure method.

    Science.gov (United States)

    Wang, Zhihui; Zhang, Ling; Liu, Jin; Jiang, Hao; Li, Chunzhong

    2018-05-30

    Recently, flexible pressure sensors featuring high sensitivity, broad sensing range and real-time detection have aroused great attention owing to their crucial role in the development of artificial intelligent devices and healthcare systems. Herein, highly sensitive pressure sensors based on hemisphere-microarray flexible substrates are fabricated via inversely templating honeycomb structures deriving from a facile and static breath figure process. The interlocked and subtle microstructures greatly improve the sensing characteristics and compressibility of the as-prepared pressure sensor, endowing it a sensitivity as high as 196 kPa-1 and a wide pressure sensing range (0-100 kPa), as well as other superior performance, including a lower detection limit of 0.5 Pa, fast response time (10 000 cycles). Based on the outstanding sensing performance, the potential capability of our pressure sensor in capturing physiological information and recognizing speech signals has been demonstrated, indicating promising application in wearable and intelligent electronics.

  11. Pressure pain sensitivity maps, self-reported musculoskeletal disorders and sickness absence among cleaners

    DEFF Research Database (Denmark)

    Binderup, Asbjørn Thalund; Holtermann, Andreas; Søgaard, Karen

    2011-01-01

    back regions (27 points). LTSA was defined as ten or more consecutive workdays with sick leave. RESULTS: The PPT maps revealed the spatial heterogeneity in mechanical sensitivity among cleaners. The level of pain in the neck and dominant shoulder and upper back within the last 7 days correlated......BACKGROUND: Pressure pain threshold mapping is a valuable method for the identification of distinct zones of mechanical pain sensitivity. Such approach was applied for the first time in relation to self-reported musculoskeletal disorders and long-term sickness absence (LTSA) within the last 12...... months among cleaners. METHODS: About 29 cleaners filled out a self-administered questionnaire regarding health, work-related measures and musculoskeletal disorders. Subsequently, PPTs were measured at (1) tibialis anterior (control location, 1 point), (2) the neck-shoulder (48 points) and (3) the low...

  12. Latex paint as a delivery vehicle for diethylphthalate and di-n-butylphthalate

    DEFF Research Database (Denmark)

    Schripp, Tobias; Salthammer, Tunga; Fauck, Christian

    2014-01-01

    gas-phase concentration at steady state(y). For both, DEP and DnBP, the y0 obtained was lower than the respective saturation vapor pressure (Ps). Furthermore, for both phthalates in latex paint, the material/air partition coefficient (C0/y0) was close in value to the octanol/air partition coefficient...

  13. Structuralist readings: Painting vs. picture

    OpenAIRE

    Marinkov-Pavlović Lidija

    2016-01-01

    The aim of the paper is to point to two fundamentally different strategies of painting practice, that is, to two subsystems of painting: picture and painting. This differentiation can be made within the framework of semiotic and semiological analyses which have developed in theory under the influence of structuralism. The first part of the paper offers a basic insight into the linguistic foundation of structuralistic concept, and then sets a thesis about the possibility of analogue reconceptu...

  14. A novel silanized CoFe{sub 2}O{sub 4}/fluorinated waterborne polyurethane pressure sensitive adhesive

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Heqing, E-mail: fuhq@scut.edu.cn; Wang, Yin; Chen, Weifeng; Zhou, Wei; Xiao, Jing

    2015-10-01

    Highlights: • The hydrophobicity, thermal stability, dynamic mechanical properties, as well as adhesive properties of silanized. • CoFe{sub 2}O{sub 4}/fluorinated waterborne polyurethane (SC/FWPU) were improved with the incorporation of silanized CoFe{sub 2}O{sub 4} into FWPU. • The higher the spreading-penetration parameter is, the faster the contact angle reaches equilibrium, and the faster the SC/FWPU pressure sensitive adhesive penetrates and spreads. - Abstract: A novel silanized CoFe{sub 2}O{sub 4}/fluorinated waterborne polyurethane (SC/FWPU) pressure sensitive adhesive was synthesized and characterized by atomic force microscopy (AFM), thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and contact angle tester. The adhesive properties were measured in a test machine. Experimental results showed that the hydrophobicity, thermal stability, dynamic mechanical properties, as well as adhesive properties of SC/FWPU were improved with the incorporation of SC into FWPU. The dynamic hydrophobicity can be well described by the wetting kinetic model. The spreading-penetration parameter increased with an increase in SC content. The higher the spreading-penetration parameter is, the faster the contact angle reaches equilibrium, and the faster the SC/FWPU pressure sensitive adhesive penetrates and spreads.

  15. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    Science.gov (United States)

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity

  16. Painting for nuclear power stations and machinery and equipments according to quality assurance program of ANSI

    International Nuclear Information System (INIS)

    Fukuda, Shinzo; Tsuchiya, Yukikazu.

    1979-01-01

    Recently, painting for nuclear power stations is carried out with the paints made domestically, and these paints are tested and judged generally according to the items of performance evaluation decided by the American National Standard Institute. In Japan, there is no standard regarding the paints for nuclear power stations. Painting is very important process, and it is appropriate to introduce quality assurance program into it. In this paper, the contents of ANSI standard concerning the paints and painting for nuclear power stations are explained, and the outline of the painting of heat exchangers carried out in accordance with the quality assurance program in the Tamano Shipyard, Mitsui Shipbuilding and Engineering Co., Ltd., is described. The test items for evaluating the general performance of the paints, the testing method for evaluating the endurance at the time of an accident, the quality assurance for the paints used for the facilities handling radiation and others are explained. Various problems arise when the quality assurance program of ANSI is applied actually to painting. It is difficult to judge the quality of paints and painting with numerical values, and much efforts were required to establish the quality assurance organization. The conditions for painting, the handling of many documents, the measures to unsatisfactory painting and so on caused much difficulties. (Kako, I.)

  17. Recent studies of laser science in paintings conservation and research.

    Science.gov (United States)

    Pouli, Paraskevi; Selimis, Alexandros; Georgiou, Savas; Fotakis, Costas

    2010-06-15

    The removal of aged and deteriorated molecular overlayers from the surface of paintings is a delicate and critical intervention in Cultural Heritage (CH) conservation. This irreversible action gets particularly complicated given the multitude of materials that may be present within a painted work of art (often in ultrathin layers or traces), as well as the exceptional sensitivity of the original surfaces to environmental conditions such as heat, light, and so on. Lasers hold an important role among the available cleaning methodologies, as they enable high control and accuracy, material selectivity, and immediate feedback. Still, prior to their implementation, it is imperative to optimize the cleaning parameters, so to ensure that any potential implications to the remaining materials are minimal and well understood. Toward this aim, research at IESL-FORTH is focused on both refining and continuously updating the laser-cleaning protocols (by introducing novel laser technologies into the field, i.e., ultrashort laser pulses), as well as on investigating and studying the nature and extent of laser-induced physicochemical alterations to the involved materials. In this Account, extended work for the understanding of ultraviolet (UV) laser ablation of polymers is presented. Emphasis is placed on the use of model systems (polymers doped with chromophores of known photochemistry) to examine the in-depth laser-induced modifications at the processed surfaces and thus to illustrate the dependence of their nature and extent on laser parameters and material properties. Furthermore, studies for the potential use of femtosecond UV pulses to overcome certain limitations involved with the nanosecond ablation of molecular overlayers from CH surfaces are highlighted. In particular, it is demonstrated that in the femtosecond regime any chemical modifications are, qualitatively and quantitatively, highly defined, limited and nearly independent of the material properties, such as the

  18. Novel paint design based on nanopowder to protection against X and gamma rays

    International Nuclear Information System (INIS)

    Movahedi, Mohammad Mehdi; Abdi, Adibe; Mehdizadeh, Alireza; Dehghan, Naser; Heidari, Emad; Masumi, Yusef; Abbaszadeh, Mojtaba

    2014-01-01

    Lead-based shields are the standard method of intraoperative radiation protection in the radiology and nuclear medicine department. Human lead toxicity is well documented. The lead used is heavy, lacks durability, is difficult to launder, and its disposal is associated with environmental hazards. The aim of this study was to design a lead free paint for protection against X and gamma rays. In this pilot st we evaluated several types of nano metal powder that seemed to have good absorption. The Monte Carlo code, MCNP4C, was used to model the attenuation of X-ray photons in paints with different designs. Experimental measurements were carried out to assess the attenuation properties of each paint design. Among the different nano metal powder, nano tungsten trioxide and nano tin dioxide were the two most appropriate candidates for making paint in diagnostic photon energy range. Nano tungsten trioxide (15%) and nano tin dioxide (85%) provided the best protection in both simulation and experiments. After this step, attempts were made to produce appropriate nano tungsten trioxide-nano tin dioxide paints. The density of this nano tungsten trioxide-nano tin dioxide paint was 4.2 g/cm 3 . The MCNP simulation and experimental measurements for HVL (Half-Value Layer) values of this shield at 100 kVp were 0.25 and 0.23 mm, respectively. The results showed the cost-effective lead-free paint can be a great power in absorbing the X-rays and gamma rays and it can be used instead of lead

  19. Preparation of water paint by radiation

    International Nuclear Information System (INIS)

    Makuuchi, Keizo

    1984-01-01

    The development of coatings which do not require any organic solvent have been the social needs. The emulsion made by radiation method is considered to meet possibly this requirement, but it has not been utilized well in the application to water paint. In this review, the investigation concerning the synthesis of water paint raw material by radiation is summarized. In the introduction, radiation curing, water paint and radiation emulsion polymerization are outlined, in the section of γ-ray emulsion polymerization, clean emulsion, cross-linked polymer particles and low temperature polymerization are described, and in the section of paint characteristics of radiation-induced emulsion-polymerized emulsion, the synthesis of thermosetting emulsion, the relation between the method of polymerization and the properties of emulsion, the performance of coating film, and self-hardening emulsion are explained. In the following section of skin-core double layer structured particle emulsion, skin-core double layer structured particles, optimal monomer composition, optimal polymerization process, the manufacturing test with a pilot plant, the performance of the paint, the durability of skin-core double layer structured particle coating film and low temperature curing water paint are described, and in the section of synthesis of emulsion by utilization of electron beam, electron beam emulsion polymerization and the synthesis of water paint by electron beam graft polymerization are described. (Yoshitake, I.)

  20. Denotative and connotative meanings of paintings

    Directory of Open Access Journals (Sweden)

    Vasić Sandra

    2007-01-01

    Full Text Available In this study the relationships between judgments of paintings denotative and connotative meanings was investigated. Denotative domain was defined as motif (represented object, e.g. portrait, landscape etc. and message (information carried by paintings, e.g. celebration of patriotism. Connotative domain was defined as subjective experience, i.e. affective or metaphoric impression produced by painting (e.g. feeling of pleasure, impression of dynamics, and so on. In preliminary study the list of 39 motifs was specified empirically. The four dimensions of pictorial message were taken from the previous study (Marković, 2006: Subjectivism, Ideology, Decoration and Constructivism vs. Realism. The four dimensions of paintings subjective experience were taken from the previous study as well (Radonjić and Marković, 2005: Regularity, Attraction, Arousal and Relaxation. In Experiment 1 subjects were asked to associate 39 motifs with 18 paintings. In Experiment 2 subjects were asked to judge 24 paintings on four dimensions of pictorial message. Results form Experiment 1 have shown that dimensions of paintings subjective experience were significantly correlated with only five motifs (e.g. everyday life was negatively correlated with Arousal, battle was negatively correlated with Relaxation, and so on. Results from Experiment 2 have shown that Subjectivism and Constructivism are negatively correlated with Regularity, and positively correlated with Arousal. Decoration is negatively correlated with Arousal and positively with Attraction and Relaxation.

  1. The Monitoring and Analysis of the Chinese Traditional Architecture Painting Decay - the Case of Jilan Pavilion in the Summer Palace

    Science.gov (United States)

    Zhan, L.; Wang, Z.; Zhao, X.; Liu, Z.; Liu, G.

    2017-08-01

    The painting is one of the most decorative elements of ancient Chinese architecture and it is sensitive to the natural environment. The outdoor painting is very easily to be affected by the natural environment and its color is easily to decay. In order to study the relationship between the painting decay and the physical environment, the two paintings on both east and west inner eaves of Jilan Pavilion beside the Kunming Lake in Summer Palace are taken as the research objects, because these two paintings are painted at the same period but their decay degrees are greatly different. Since 2013, the research group regularly monitors the color decay of these two paintings. Meanwhile, the physical environment around these two paintings has been monitored. Based on the analysis of the monitor data, it can be seen that the illumination is the major factor that causes the decay of the painting. Meanwhile, by using the ECOTECT software to stimulate the light environment around the Jilan Pavilion, it can be seen that it is the mirror reflection of the lake that causes the result that the illumination of the west eave (face east) is stronger than that of the east eave (face west).

  2. Investigating the effect of artists’ paint formulation on degradation rates of TiO2‑based oil paints

    NARCIS (Netherlands)

    van Driel, B.A.; van den Berg, K. J.; Smout, M.; Dekker, N; Kooyman, P.J.; Dik, J.

    2018-01-01

    This study reports on the effect of artists’ paint formulation on degradation rates of TiO2-based oil paints. Titanium white oil paint exists in a multitude of different recipes, and the effect of the formulation on photocatalytic binder
    degradation kinetics is unknown. These formulations

  3. Women's finger pressure sensitivity at rest and recalled body awareness during partnered sexual activity.

    Science.gov (United States)

    Costa, R M; Pestana, José; Costa, David; Wittmann, Marc

    2017-07-01

    Greater vibrotactile sensitivity has been related to better erectile function in men, and vibrotactile and pressure tactile sensitivity have been related to better sexual function in women. Our previous study found that, for both sexes, greater recalled body awareness during last sexual relation correlated with greater recalled desire and arousal. Using the same sample of that study (68 women and 48 men, recruited in the Lisbon area, Portugal), we tested if greater recalled body awareness during last sexual relation correlates with tactile pressure sensitivity, as assessed by von Frey microfilaments. In simple and partial correlations controlling for social desirability and smoking before last sex, the hypothesis was confirmed for women, but not for men. Greater tactile sensitivity might enhance sexual arousal through greater awareness of the body during sex, and/or more frequent and pleasant body sensations during sex might lead to greater tactile sensitivity in nonsexual situations. Pressure sensitivity might be more closely linked to sexual arousal in women than in men.

  4. Highly Sensitive, Transparent, and Durable Pressure Sensors Based on Sea-Urchin Shaped Metal Nanoparticles.

    Science.gov (United States)

    Lee, Donghwa; Lee, Hyungjin; Jeong, Youngjun; Ahn, Yumi; Nam, Geonik; Lee, Youngu

    2016-11-01

    Highly sensitive, transparent, and durable pressure sensors are fabricated using sea-urchin-shaped metal nanoparticles and insulating polyurethane elastomer. The pressure sensors exhibit outstanding sensitivity (2.46 kPa -1 ), superior optical transmittance (84.8% at 550 nm), fast response/relaxation time (30 ms), and excellent operational durability. In addition, the pressure sensors successfully detect minute movements of human muscles. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Beauty in abstract paintings: perceptual contrast and statistical properties

    Science.gov (United States)

    Mallon, Birgit; Redies, Christoph; Hayn-Leichsenring, Gregor U.

    2014-01-01

    In this study, we combined the behavioral and objective approach in the field of empirical aesthetics. First, we studied the perception of beauty by investigating shifts in evaluation on perceived beauty of abstract artworks (Experiment 1). Because the participants showed heterogeneous individual preferences for the paintings, we divided them into seven clusters for the test. The experiment revealed a clear pattern of perceptual contrast. The perceived beauty of abstract paintings increased after exposure to paintings that were rated as less beautiful, and it decreased after exposure to paintings that were rated as more beautiful. Next, we searched for correlations of beauty ratings and perceptual contrast with statistical properties of abstract artworks (Experiment 2). The participants showed significant preferences for particular image properties. These preferences differed between the clusters of participants. Strikingly, next to color measures like hue, saturation, value and lightness, the recently described Pyramid of Histograms of Orientation Gradients (PHOG) self-similarity value seems to be a predictor for aesthetic appreciation of abstract artworks. We speculate that the shift in evaluation in Experiment 1 was, at least in part, based on low-level adaptation to some of the statistical image properties analyzed in Experiment 2. In conclusion, our findings demonstrate that the perception of beauty in abstract artworks is altered after exposure to beautiful or non-beautiful images and correlates with particular image properties, especially color measures and self-similarity. PMID:24711791

  6. Conservation problems with paintings containing fluorescent layers of paint

    Directory of Open Access Journals (Sweden)

    Stefanie De Winter

    2010-11-01

    Full Text Available L’artiste moderne cherche continuellement de nouvelles techniques. Des nouveaux matériaux tels que l’éponge, le polyester, le sable, etc. sont devenus courants. Ces développements amènent de nouveaux problèmes dans le domaine de la conservation (préventive des matériaux en question. Chaque matériau doit être analysé individuellement afin de préserver  le mieux possible l’intention de l’artiste à long terme. La présente recherche concerne des matériaux très récents: les pigments et les couleurs fluorescentes. Ces derniers n’ont fait leur apparition qu’au vingtième siècle. Pour cette raison les données concernant leur dégradation et leur conservation sont peu nombreuses. La majorité des tableaux fluorescents sont conçus pour être montrés sous éclairage UV. En cas de dommage, si l’œuvre a besoin d’être retouchée, ceci pose un grand problème esthétique. La retouche devient visible sous les lampes UV. La première partie de la recherche concerne la composition des différentes sortes de pigments et de peintures. Par la suite, les différentes causes de dégradation- lumière UV, chaleur, etc.- sont analysées en détail. Pour conclure, un possible remède est proposé.In modern art we can see that artists are breaking with traditional techniques. New materials like sponge, polyester, sand, etc. are being used. This causes a lot of new problems in the (preventive conservation of works containing these materials. Every material needs to be researched individually so the exact intention of the artist can be preserved for a (relatively long period. My research is about very recent materials: fluorescent pigments and paints. These only started to be used by artists from the 60’s. That's why there is not much information about their aging and ways to (preventively conserve them. A lot of fluorescent paintings are meant to be shown under UV-light. If a fluorescent painting has damage and needs to be retouched

  7. Analyzing FTIR spectra using high sensitivity compare function of FTIR software for 2-pack epoxy paints

    Science.gov (United States)

    Saaid, Farish Irfal; Chan, Chin Han; Ong, Max Chong Hup; Winie, Tan; Harun, Mohamad Kamal

    2015-08-01

    The existing problem of oil and gas companies faced for on-site jobs of polymeric coatings on steel pipelines is that the quality of polymeric coatings varies from job to job for the same product brand from the same supplier or paint manufacturer. This can be due to the inherent problem of the reformulation of polymeric coatings or in other words adulterated polymeric coatings are supplied, where the quality of the coatings deviates from the submitted specifications for prequalification and tender purpose. Major oil and gas companies in Malaysia are calling for Coating Fingerprinting Certificate for the supply of polymeric coatings from local paint manufactures as quality assurance requirement of the coatings supplied. This will reduce the possibility of failures of the polymeric coatings, which lead to the corrosion of steel pipelines resulting in leakage of crude oil and gas to the environment. In this case, Fourier-transform infrared (FTIR) is a simple and reliable tool for coating fingerprinting. In this study, we conclude that, revelation of possible components of the 2-pack epoxy paints by carrying out extensive FTIR libraries search on FTIR spectra seems to be extremely challenging. Estimation of correlation of the sample spectrum to that of the reference spectrum using Compare function from one FTIR manufacturer, even the FTIR spectra are collected by different FTIR spectrometers from different FTIR manufacturers, can be made. The results of the correlation are reproducible.

  8. LSST Painting Risk Evaluation Memo

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, Justin E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-11-10

    The optics subsystem is required to paint the edges of optics black where possible. Due to the risks in applying the paint LSST requests a review of the impact of removing this requirement for the filters and L3.

  9. A Flexible Sensor Technology for the Distributed Measurement of Interaction Pressure

    Science.gov (United States)

    Donati, Marco; Vitiello, Nicola; De Rossi, Stefano Marco Maria; Lenzi, Tommaso; Crea, Simona; Persichetti, Alessandro; Giovacchini, Francesco; Koopman, Bram; Podobnik, Janez; Munih, Marko; Carrozza, Maria Chiara

    2013-01-01

    We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted. PMID:23322104

  10. Association between Depression, Pressure Pain Sensitivity, Stress and Autonomous Nervous System Function in Stable Ischemic Heart Disease

    DEFF Research Database (Denmark)

    Ballegaard, Søren; Bergmann, Natasha; Karpatschof, Benny

    2016-01-01

    Background: Depression and ischemic heart disease (IHD) are associated with persistent stress and autonomic nervous system (ANS) dysfunction. The former can be measured by pressure pain sensitivity (PPS) of the sternum, and the latter by the PPS and systolic blood pressure (SBP) response to a til...... in depression, reduction in persistent stress, and restoration of ANS dysfunction was only seen in non-users, suggesting a central role of beta-adrenergic receptors in the association between these factors....

  11. Internal contamination by tritium caused by radioluminescent paints

    Energy Technology Data Exchange (ETDEWEB)

    Adamiak-Ziemba, J.; Doniec, J.

    1985-01-01

    The internal contamination investigations covered 23 persons using radioluminescence paints containing tritium, assembling devices painted with those paints, and those having no contact with active paints but working next to the painting room. Determined were concentrations of tritium excreted with urine, air contamination at workplaces, contamination of workplace areas and hand skin. At the time covered by the investigations, the mean annual equivalent doses for those using tritium paints were reduced from 14-20 mSv to about 5 mSv. In those working next to the painting room they were reduced from 5.8-15 to 0.23 mSv. The exposure of those assembling the devices does not exceed 1 mSv. It was demonstrated that the main cause of the tritium exposure level was air contamination in working rooms.

  12. Measurement of carotid bifurcation pressure gradients using the Bernoulli principle.

    Science.gov (United States)

    Illig, K A; Ouriel, K; DeWeese, J A; Holen, J; Green, R M

    1996-04-01

    Current randomized prospective studies suggest that the degree of carotid stenosis is a critical element in deciding whether surgical or medical treatment is appropriate. Of potential interest is the actual pressure drop caused by the blockage, but no direct non-invasive means of quantifying the hemodynamic consequences of carotid artery stenoses currently exists. The present prospective study examined whether preoperative pulsed-Doppler duplex ultrasonographic velocity (v) measurements could be used to predict pressure gradients (delta P) caused by carotid artery stenoses, and whether such measurements could be used to predict angiographic percent diameter reduction. Preoperative Doppler velocity and intraoperative direct pressure measurements were obtained, and per cent diameter angiographic stenosis measured in 76 consecutive patients who underwent 77 elective carotid endarterectomies. Using the Bernoulli principle (delta P = 4v(2), pressure gradients across the stenoses were calculated. The predicted delta P, as well as absolute velocities and internal carotid artery/common carotid velocity ratios were compared with the actual delta P measured intraoperatively and with preoperative angiography and oculopneumoplethysmography (OPG) results. An end-diastolic velocity of > or = 1 m/s and an end-diastolic internal carotid artery/common carotid artery velocity ratio of > or = 10 predicted a 50% diameter angiographic stenosis with 100% specificity. Although statistical significance was reached, preoperative pressure gradients derived from the Bernoulli equation could not predict actual individual intraoperative pressure gradients with enough accuracy to allow decision making on an individual basis. Velocity measurements were as specific and more sensitive than OPG results. Delta P as predicted by the Bernoulli equation is not sufficiently accurate at the carotid bifurcation to be useful for clinical decision making on an individual basis. However, end

  13. Epoxy-paint stripping using TEA CO2 laser: Determination of threshold fluence and the process parameters

    Science.gov (United States)

    Kumar, Manoj; Bhargava, P.; Biswas, A. K.; Sahu, Shasikiran; Mandloi, V.; Ittoop, M. O.; Khattak, B. Q.; Tiwari, M. K.; Kukreja, L. M.

    2013-03-01

    It is shown that the threshold fluence for laser paint stripping can be accurately estimated from the heat of gasification and the absorption coefficient of the epoxy-paint. The threshold fluence determined experimentally by stripping of the epoxy-paint on a substrate using a TEA CO2 laser matches closely with the calculated value. The calculated threshold fluence and the measured absorption coefficient of the paint allowed us to determine the epoxy paint thickness that would be removed per pulse at a given laser fluence even without experimental trials. This was used to predict the optimum scan speed required to strip the epoxy-paint of a given thickness using a high average power TEA CO2 laser. Energy Dispersive X-Ray Fluorescence (EDXRF) studies were also carried out on laser paint-stripped concrete substrate to show high efficacy of this modality.

  14. Characterization of Aerosols Generated by nano-second Laser Ablation of an Acrylic Paint

    International Nuclear Information System (INIS)

    Dewalle, P.; Vendel, J.; Dewalle, P.; Weulersse, J.M.; Dewalle, P.; Herve, Ph.; Dewalle, P.; Decobert, G.

    2010-01-01

    This study focuses on particles produced during laser ablation of a green colored acrylic wall paint, which is frequently used in industrial buildings and in particular in nuclear installations. Ablation is carried out with a Nd:YAG laser at a wavelength of 532 nm and a pulse duration of 5 ns, in a cell at ambient pressure and temperature, which is ventilated by filtered air. The number of particles emitted was measured with a Condensation Particle Counter (CPC) and their size with an Engine Exhaust Particle Sizer (or EEPS) for the nano-metric range, and an AEROSIZER (for the micrometric range). The mass and shape of particles were determined by sampling on filters as well as on the different impaction plates of a Low-Pressure Impactor (LPI). Two particle populations were detected: a population of aggregates of primary nano-particles with an electrical mobility diameter ranging from 30 to 150 nm, and a population of spherical submicron particles with an aerodynamic diameter ranging from 400 to 1000 nm. The spherical particles are mainly composed of titanium dioxide, and the aggregates most likely of carbon. The presence of two types of particles with different size distributions, shapes, and chemical compositions, implies that particles originating from the ablation of paint are formed by two different mechanisms: agglomeration in the case of the nano-metric aggregates, which is preceded by steps of nucleation, condensation, and coagulation of the primary particles, while the submicron spheres result from a direct ejection mechanism. (authors)

  15. Effects of wall temperature on skin-friction measurements by oil-film interferometry

    International Nuclear Information System (INIS)

    Bottini, H; Kurita, M; Iijima, H; Fukagata, K

    2015-01-01

    Wind-tunnel skin-friction measurements with thin-oil-film interferometry have been taken on an aluminum sample to investigate the effects of wall temperature on the accuracy of the technique. The sample has been flush-mounted onto a flat plate with an electric heater at its bottom and mirror-smooth temperature-sensitive paint sprayed on its top. The heater has varied the sample temperature from ambient to 328 K, and the paint has permitted wall temperature measurements on the same area of the skin-friction measurements and during the same test. The measured wall temperatures have been used to calculate the correct oil viscosities, and these viscosities and the constant nominal viscosity at 298 K have been used to calculate two different sets of skin-friction coefficients. These sets have been compared to each other and with theoretical values. This comparison shows that the effects of wall temperature on the accuracy of skin-friction measurements are sensible, and more so as wall temperature differs from 298 K. Nonetheless, they are effectively neutralized by the use of wall temperature measurements in combination with the correct oil viscosity–temperature law. In this regard, the special temperature-sensitive paint developed for this study shows advantages with respect to more traditional wall temperature measurement techniques. (paper)

  16. Subjective Ratings of Beauty and Aesthetics: Correlations With Statistical Image Properties in Western Oil Paintings

    Science.gov (United States)

    Lehmann, Thomas; Redies, Christoph

    2017-01-01

    For centuries, oil paintings have been a major segment of the visual arts. The JenAesthetics data set consists of a large number of high-quality images of oil paintings of Western provenance from different art periods. With this database, we studied the relationship between objective image measures and subjective evaluations of the images, especially evaluations on aesthetics (defined as artistic value) and beauty (defined as individual liking). The objective measures represented low-level statistical image properties that have been associated with aesthetic value in previous research. Subjective rating scores on aesthetics and beauty correlated not only with each other but also with different combinations of the objective measures. Furthermore, we found that paintings from different art periods vary with regard to the objective measures, that is, they exhibit specific patterns of statistical image properties. In addition, clusters of participants preferred different combinations of these properties. In conclusion, the results of the present study provide evidence that statistical image properties vary between art periods and subject matters and, in addition, they correlate with the subjective evaluation of paintings by the participants. PMID:28694958

  17. Metabolic syndrome and salt sensitivity of blood pressure in non-diabetic people in China: a dietary intervention study.

    Science.gov (United States)

    Chen, Jing; Gu, Dongfeng; Huang, Jianfeng; Rao, Dabeeru C; Jaquish, Cashell E; Hixson, James E; Chen, Chung-Shiuan; Chen, Jichun; Lu, Fanghong; Hu, Dongsheng; Rice, Treva; Kelly, Tanika N; Hamm, L Lee; Whelton, Paul K; He, Jiang

    2009-03-07

    Since insulin resistance is thought to be the underlying mechanism for metabolic syndrome, affected individuals might be sensitive to a dietary sodium intervention. We aimed to examine the association between metabolic syndrome and salt sensitivity of blood pressure. 1906 Chinese participants without diabetes, aged 16 years or more, were selected to receive a low-sodium diet (51.3 mmol per day) for 7 days followed by a high-sodium diet (307.8 mmol per day) for an additional 7 days. Participants were excluded from the analysis if metabolic risk factor information was missing or if they did not complete their dietary interventions. Blood pressure was measured at baseline and on days 2, 5, 6, and 7 of each intervention. Metabolic syndrome was defined as the presence of three or more of: abdominal obesity, raised blood pressure, high triglyceride concentration, low HDL cholesterol, or high glucose. High salt sensitivity was defined as a decrease in mean arterial blood pressure of more than 5 mm Hg during low-sodium or an increase of more than 5 mm Hg during high-sodium intervention. This study is registered with ClinicalTrials.gov, number NCT00721721. Of the 1881 participants with information regarding metabolic syndrome, 283 had metabolic syndrome. 1853 participants completed the low-sodium diet and 1845 completed the high-sodium diet. Multivariable-adjusted mean changes in blood pressure were significantly greater in participants with metabolic syndrome than in those without on both low-sodium and high-sodium diets (plow-sodium and a 3.13-fold increased odds (1.80-5.43) of high salt-sensitivity during the high-sodium intervention. These results suggest that metabolic syndrome enhances blood pressure response to sodium intake. Reduction in sodium intake could be an especially important component in reducing blood pressure in patients with multiple risk factors for metabolic syndrome.

  18. Unsteady pressures on a blunt trailing edge measured with an embedded pressure scanner

    Science.gov (United States)

    Naughton, Jonathan; Nikoueeyan, Pourya; Hind, Michael; Strike, John; Dahland, Matz; Keeter, Steven

    2017-11-01

    Development of direct-mount pressure scanners can decrease the pneumatic tubing length required to connect the measurement ports to the scanner manifold resulting in improved dynamic range for unsteady pressure measurements. In this work, the performance of a direct-mount pressure scanner for time-resolved pressure measurement is demonstrated in a well-established flow; the pressure fluctuations near the base of flat plate is considered. The additive manufactured model is instrumented with a pressure scanner and flush-mounted high-speed pressure transducers. The configuration of the ports on the model allows for side-by-side comparison of the pressures measured via embedded pneumatic tubing routed to a pressure scanner with that measured by high-speed transducers. Prior to testing, the dynamic response of each embedded pressure port is dynamically calibrated via an in-situ calibration technique. Pressure data is then acquired for fixed angle-of-attack and different dynamic pitching conditions. The dynamic range of the measurements acquired via direct-mount scanner will be compared to those acquired by the high speed transducers for both static and dynamic pitching configurations. The uncertainties associated with Weiner deconvolution are also quantified for the measurements.

  19. Evaluation of high pressure water blast with rotating spray bar for removing paint and rubber deposits from airport runways, and review of runway slipperiness problems created by rubber contamination

    Science.gov (United States)

    Horne, W. B.; Griswold, G. D.

    1975-01-01

    A high pressure water blast with rotating spray bar treatment for removing paint and rubber deposits from airport runways is studied. The results of the evaluation suggest that the treatment is very effective in removing above surface paint and rubber deposits to the point that pavement skid resistance is restored to trafficked but uncontaminated runway surface skid resistance levels. Aircraft operating problems created by runway slipperiness are reviewed along with an assessment of the contributions that pavement surface treatments, surface weathering, traffic polishing, and rubber deposits make in creating or alleviating runway slipperiness. The results suggest that conventional surface treatments for both portland cement and asphaltic concrete runways are extremely vulnerable to rubber deposit accretions which can produce runway slipperiness conditions for aircraft operations as or more slippery than many snow and ice-covered runway conditions. Pavement grooving surface treatments are shown to be the least vulnerable to rubber deposits accretion and traffic polishing of the surface treatments examined.

  20. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  1. Airborne allergic contact dermatitis caused by isothiazolinones in water-based paints: a retrospective study of 44 cases.

    Science.gov (United States)

    Amsler, Emmanuelle; Aerts, Olivier; Raison-Peyron, Nadia; Debons, Michèle; Milpied, Brigitte; Giordano-Labadie, Françoise; Waton, Julie; Ferrier-Le Bouëdec, Marie C; Lartigau, Isabelle; Pecquet, Catherine; Assier, Haudrey; Avenel-Audran, Martine; Bernier, Claire; Castelain, Florence; Collet, Evelyne; Crépy, Marie-Noëlle; Genillier, Nathalie; Girardin, Pascal; Pralong, Pauline; Tetart, Florence; Vital-Durand, Dominique; Soria, Angele; Barbaud, Annick

    2017-09-01

    Airborne allergic contact dermatitis caused by paints containing isothiazolinones has been recognized as a health hazard. To collect epidemiological, clinical and patch test data on airborne allergic contact dermatitis caused by isothiazolinone-containing paints in France and Belgium. A descriptive, retrospective study was initiated by the Dermatology and Allergy Group of the French Society of Dermatology, including methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI)- and/or MI-sensitized patients who developed airborne allergic contact dermatitis following exposure to isothiazolinone-containing paint. Forty-four cases were identified, with mostly non-occupational exposure (79.5%). Of the patients, 22.5% of also had mucosal symptoms. In several cases, the dermatitis required systemic corticosteroids (27.3%), hospitalization (9.1%), and/or sick leave (20.5%). A median delay of 5.5 weeks was necessary to enable patients to enter a freshly painted room without a flare-up of their dermatitis. Approximately one-fifth of the patients knew that they were allergic to MI and/or MCI/MI before the exposure to paints occurred. Our series confirms that airborne allergic contact dermatitis caused by paints containing isothiazolinones is not rare, and may be severe and long-lasting. Better regulation of isothiazolinone concentrations in paints, and their adequate labelling, is urgently needed. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Neural correlates of viewing paintings

    DEFF Research Database (Denmark)

    Vartanian, Oshin; Skov, Martin

    2014-01-01

    Many studies involving functional magnetic resonance imaging (fMRI) have exposed participants to paintings under varying task demands. To isolate neural systems that are activated reliably across fMRI studies in response to viewing paintings regardless of variation in task demands, a quantitative...

  3. New biocides for antifouling paints

    International Nuclear Information System (INIS)

    Mazziotti, Isabella; Massanisso, Paolo; Cremisini, Carlo; Chiavarini, Salvatore; Fantini, Michele; Morabito, Roberto

    2005-01-01

    The antifouling paints are used for protecting the hulls of the boasts from the undesirable accumulation of micro-organisms, plants, and animals on artificial surfaces (marine biological fouling). These paints constitute a potential risk for the marine environment, because of the presence in their formulation, among the other potentially toxic components, of organic compounds acting as biocide. The environmental problems associated with the use of the organotin compounds as biocides in the antifouling paints, have lead to the international ban of these compounds. In the article the new antifouling paints coming up the national and international market are shortly introduced and discussed, with particular attention respect to the new organic compounds used as biocides. In Italy quite a few marine monitoring campaigns have been carried out for organotin compounds, on the contrary there is a lack of data regarding the presence of other biocides [it

  4. High-resolution fluorescence mapping of impurities in historical zinc oxide pigments: hard X-ray nanoprobe applications to the paints of Pablo Picasso

    International Nuclear Information System (INIS)

    Casadio, Francesca; Rose, Volker

    2013-01-01

    Here for the first time we describe the use of high resolution nanoprobe X-ray fluorescence (XRF) mapping for the analysis of artists' paints, hierarchically complex materials typically composed of binder, pigments, fillers, and other additives. The work undertaken at the nanoprobe sought to obtain highly spatially resolved, highly sensitive mapping of metal impurities (Pb, Cd, Fe, and other metals) in submicron particles of zinc oxide pigments used in early 20th century artists' tube paints and enamel paints, with particular emphasis on Ripolin, a popular brand of French house paint used extensively by Pablo Picasso and some of his contemporaries. Analysis revealed that the Zn oxide particles only contain a little Fe, proving that the highest quality Zn oxide pigment, free of Pb and Cd, was used for Ripolin house paints as well as artists' paints. Nanoprobe XRF mapping also demonstrated that artists' tube paints generally have more abundant fillers and additional whites (based on Pb, Ti, Ca) than Ripolin paints, which contain mostly pure zinc oxide. The chemical characterization of paints at the nanoscale opens the path to a better understanding of their fabrication and chemical reactivity. (orig.)

  5. High-resolution fluorescence mapping of impurities in historical zinc oxide pigments: hard X-ray nanoprobe applications to the paints of Pablo Picasso

    Energy Technology Data Exchange (ETDEWEB)

    Casadio, Francesca [The Art Institute of Chicago, Chicago, IL (United States); Rose, Volker [Argonne National Laboratory, Advanced Photon Source and Center for Nanoscale Materials, Argonne, IL (United States)

    2013-04-15

    Here for the first time we describe the use of high resolution nanoprobe X-ray fluorescence (XRF) mapping for the analysis of artists' paints, hierarchically complex materials typically composed of binder, pigments, fillers, and other additives. The work undertaken at the nanoprobe sought to obtain highly spatially resolved, highly sensitive mapping of metal impurities (Pb, Cd, Fe, and other metals) in submicron particles of zinc oxide pigments used in early 20th century artists' tube paints and enamel paints, with particular emphasis on Ripolin, a popular brand of French house paint used extensively by Pablo Picasso and some of his contemporaries. Analysis revealed that the Zn oxide particles only contain a little Fe, proving that the highest quality Zn oxide pigment, free of Pb and Cd, was used for Ripolin house paints as well as artists' paints. Nanoprobe XRF mapping also demonstrated that artists' tube paints generally have more abundant fillers and additional whites (based on Pb, Ti, Ca) than Ripolin paints, which contain mostly pure zinc oxide. The chemical characterization of paints at the nanoscale opens the path to a better understanding of their fabrication and chemical reactivity. (orig.)

  6. Pressure drop and arterial compliance - Two arterial parameters in one measurement.

    Science.gov (United States)

    Rotman, Oren M; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2017-01-04

    Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. A Micro CO2 Gas Sensor Based on Sensing of pH-Sensitive Hydrogel Swelling by Means of a Pressure Sensor

    NARCIS (Netherlands)

    Herber, S.; Bomer, Johan G.; Olthuis, Wouter; Bergveld, Piet; van den Berg, Albert

    2005-01-01

    In this paper a sensor is presented for the detection of carbon dioxide gas inside the stomach in order to diagnose gastrointestinal ischemia. The operational principle of the sensor is measuring the CO2 induced pressure generation of a confined pH-sensitive hydrogel by means of a micro pressure

  8. Assessment of deep dynamic mechanical sensitivity in individuals with tension-type headache: The dynamic pressure algometry.

    Science.gov (United States)

    Palacios-Ceña, M; Wang, K; Castaldo, M; Guerrero-Peral, Á; Caminero, A B; Fernández-de-Las-Peñas, C; Arendt-Nielsen, L

    2017-09-01

    To explore the validity of dynamic pressure algometry for evaluating deep dynamic mechanical sensitivity by assessing its association with headache features and widespread pressure sensitivity in tension-type headache (TTH). One hundred and eighty-eight subjects with TTH (70% women) participated. Deep dynamic sensitivity was assessed with a dynamic pressure algometry set (Aalborg University, Denmark © ) consisting of 11 different rollers including fixed levels from 500 g to 5300 g. Each roller was moved at a speed of 0.5 cm/s over a 60-mm horizontal line covering the temporalis muscle. Dynamic pain threshold (DPT-level of the first painful roller) was determined and pain intensity during DPT was rated on a numerical pain rate scale (NPRS, 0-10). Headache clinical features were collected on a headache diary. As gold standard, static pressure pain thresholds (PPT) were assessed over temporalis, C5/C6 joint, second metacarpal, and tibialis anterior muscle. Side-to-side consistency between DPT (r = 0.843, p  r > 0.656, all p headaches supporting that deep dynamic pressure sensitivity within the trigeminal area is consistent with widespread pressure sensitivity. Assessing deep static and dynamic somatic tissue pain sensitivity may provide new opportunities for differentiated diagnostics and possibly a new tool for assessing treatment effects. The current study found that dynamic pressure algometry in the temporalis muscle was associated with widespread pressure pain sensitivity in individuals with tension-type headache. The association was independent of the frequency of headaches. Assessing deep static and dynamic somatic tissue pain sensitivity may provide new opportunities for differentiated diagnostics and possibly a tool for assessing treatment effects. © 2017 European Pain Federation - EFIC®.

  9. Mural Painting as Inclusive Art Learning Experience

    Science.gov (United States)

    Ho, Kong

    2010-01-01

    Traditional art education, like other academic disciplines, emphasizes competitiveness and individualism. Through a mural painting curriculum, learners participate in mural art and history appreciation, are active in mural theme or content construction, and engage in hands-on mural design and painting processes. When mural paintings are produced…

  10. An electrokinetic pressure sensor

    International Nuclear Information System (INIS)

    Kim, Dong-Kwon; Kim, Sung Jin; Kim, Duckjong

    2008-01-01

    A new concept for a micro pressure sensor is demonstrated. The pressure difference between the inlet and the outlet of glass nanochannels is obtained by measuring the electrokinetically generated electric potential. To demonstrate the proposed concept, experimental investigations are performed for 100 nm wide nanochannels with sodium chloride solutions having various concentrations. The proposed pressure sensor is able to measure the pressure difference within a 10% deviation from linearity. The sensitivity of the electrokinetic pressure sensor with 10 −5 M sodium chloride solution is 18.5 µV Pa −1 , which is one order of magnitude higher than that of typical diaphragm-based pressure sensors. A numerical model is presented for investigating the effects of the concentration and the channel width on the sensitivity of the electrokinetic pressure sensor. Numerical results show that the sensitivity increases as the concentration decreases and the channel width increases

  11. Occupational Hazards and Safety Measures Amongst the Paint Factory Workers in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Olufunsho Awodele

    2014-06-01

    Conclusion: The need to develop effective frameworks that will initiate the integration and ensure implementation of safety regulations in paint factories is evident. Where these exist, there is a need to promote adherence to these practice guidelines.

  12. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  13. Texton-based analysis of paintings

    NARCIS (Netherlands)

    Van der Maaten, L.J.P.; Postma, E.O.

    2010-01-01

    The visual examination of paintings is traditionally performed by skilled art historians using their eyes. Recent advances in intelligent systems may support art historians in determining the authenticity or date of creation of paintings. In this paper, we propose a technique for the examination of

  14. Characterisation of preparation layers in nine Danish Golden Age canvas paintings by SEM–EDX, FTIR and GC–MS

    DEFF Research Database (Denmark)

    Andersen, Cecil Krarup; Bonaduce, Ilaria; Andreotti, Alessia

    2017-01-01

    added in order to increase flexibility and durability of ready primed canvases that were stored and sold in rolls. Moreover, the egg–oil emulsion has the advantage of being more viscous than a pure oil paint and could thus be used without sizing the canvas, rendering the primed canvas less stiff......This study explores the materials used in the preparation layers of nine paintings from the Danish Golden Age as a first approach to understanding the variation in use of materials in the nineteenth century as well as the potential for their degradation. Paintings on canvas have traditionally been...... suspected to be particularly sensitive to high moisture levels because of the changing quality of materials in the nineteenth century. The explanations have partly included the mechanisation of production methods and partly a more experimental approach to painting. Additionally, collagen-based glue sizing...

  15. Sensitivity of Spores of Eight Bacillus Cereus Strains to Pressure-Induced Germination by Moderate Hydrostatic Pressure, Time and Temperature

    National Research Council Canada - National Science Library

    Kalchayanand, Norasak; Ray, Bibek; Dunne, C. P; Sikes, Anthony

    2005-01-01

    The spores of eight Bacillus cereus strains were pressurized at 138 to 483 MPa for 5 to 20 min at 25 to 70 C in order to determine the sensitive and the resistant strains to pressure-induced germination...

  16. Highly Sensitive and Patchable Pressure Sensors Mimicking Ion-Channel-Engaged Sensory Organs.

    Science.gov (United States)

    Chun, Kyoung-Yong; Son, Young Jun; Han, Chang-Soo

    2016-04-26

    Biological ion channels have led to much inspiration because of their unique and exquisite operational functions in living cells. Specifically, their extreme and dynamic sensing abilities can be realized by the combination of receptors and nanopores coupled together to construct an ion channel system. In the current study, we demonstrated that artificial ion channel pressure sensors inspired by nature for detecting pressure are highly sensitive and patchable. Our ion channel pressure sensors basically consisted of receptors and nanopore membranes, enabling dynamic current responses to external forces for multiple applications. The ion channel pressure sensors had a sensitivity of ∼5.6 kPa(-1) and a response time of ∼12 ms at a frequency of 1 Hz. The power consumption was recorded as less than a few μW. Moreover, a reliability test showed stability over 10 000 loading-unloading cycles. Additionally, linear regression was performed in terms of temperature, which showed no significant variations, and there were no significant current variations with humidity. The patchable ion channel pressure sensors were then used to detect blood pressure/pulse in humans, and different signals were clearly observed for each person. Additionally, modified ion channel pressure sensors detected complex motions including pressing and folding in a high-pressure range (10-20 kPa).

  17. Application of instrumental neutron activation analysis in investigation of pigments from historic paintings

    International Nuclear Information System (INIS)

    Stverak, B.; Tluchor, D.; Kokta, L.; Dryak, P.; Rowinska, L.; Walis, L.; Vosatka, A.

    1985-01-01

    Neutron activation analysis was used in determining the composition of used pigments, their age and origin. Microsamples from paintings with a weight of less than 10 -7 kg were taken with a hollow needle, irradiated in quartz ampoules for 20 hours in a reactor with a density of thermal neutrons of 10 13 cm -2 .s -1 and then in different configurations measured with a Ge(Li) detector. From the amount of obtained data (various paintings, different colours) a data bank will be established enabling speedy comparative evaluations. As an example the problem of the excellent white in Rubens' paintings is dealt with and the dating is discussed of the early beginnings of the use of zinc white in Guardi's paintings. (M.D.)

  18. THE MONITORING AND ANALYSIS OF THE CHINESE TRADITIONAL ARCHITECTURE PAINTING DECAY – THE CASE OF JILAN PAVILION IN THE SUMMER PALACE

    Directory of Open Access Journals (Sweden)

    L. Zhan

    2017-08-01

    Full Text Available The painting is one of the most decorative elements of ancient Chinese architecture and it is sensitive to the natural environment. The outdoor painting is very easily to be affected by the natural environment and its color is easily to decay. In order to study the relationship between the painting decay and the physical environment, the two paintings on both east and west inner eaves of Jilan Pavilion beside the Kunming Lake in Summer Palace are taken as the research objects, because these two paintings are painted at the same period but their decay degrees are greatly different. Since 2013, the research group regularly monitors the color decay of these two paintings. Meanwhile, the physical environment around these two paintings has been monitored. Based on the analysis of the monitor data, it can be seen that the illumination is the major factor that causes the decay of the painting. Meanwhile, by using the ECOTECT software to stimulate the light environment around the Jilan Pavilion, it can be seen that it is the mirror reflection of the lake that causes the result that the illumination of the west eave (face east is stronger than that of the east eave (face west.

  19. Effects of pre-strain on the intrinsic pressure sensitivity of polymer optical fiber Bragg-gratings

    DEFF Research Database (Denmark)

    Pedersen, Jens Kristian Mølgaard; Woyessa, Getinet; Nielsen, Kristian

    2017-01-01

    We experimentally demonstrate a scheme for improving the intrinsic pressure sensitivity of fiber Bragg-gratings (FBGs) inscribed in polymer optical fibers by applying pre-strain in order to suppress the pressure induced mechanical contraction of the fiber. This contraction would otherwise...... contribute to a blueshift of the Brag-wavelength, counteracting the dominant redshift caused by the stress-optic effect, which effectively reduces the pressure sensitivity of the FBG. By applying this technique we are able to improve the sensitivity of the FBG from 2.8 pm/bar to 7.3 pm/bar. © (2017...

  20. Frames as visual links between paintings and the museum environment: An analysis of statistical image properties

    Directory of Open Access Journals (Sweden)

    Christoph eRedies

    2013-11-01

    Full Text Available Frames provide a visual link between artworks and their surround. We asked how image properties change as an observer zooms out from viewing a painting alone, to viewing the painting with its frame and, finally, the framed painting in its museum environment (museum scene. To address this question, we determined three higher-order image properties that are based on histograms of oriented luminance gradients. First, complexity was measured as the sum of the strengths of all gradients in the image. Second, we determined the self-similarity of histograms of the orientated gradients at different levels of spatial analysis. Third, we analyzed how much gradient strength varied across orientations (anisotropy. Results were obtained for three art museums that exhibited paintings from three major periods of Western art. In all three museums, the mean complexity of the frames was higher than that of the paintings or the museum scenes. Frames thus provide a barrier of complexity between the paintings and their exterior. By contrast, self-similarity and anisotropy values of images of framed paintings were intermediate between the images of the paintings and the museum scenes, i.e., the frames provided a transition between the paintings and their surround. We also observed differences between the three museums that may reflect modified frame usage in different art periods. For example, frames in the museum for 20th century art tended to be smaller and less complex than in the two other two museums that exhibit paintings from earlier art periods (13th-18th century and 19th century, respectively. Finally, we found that the three properties did not depend on the type of reproduction of the paintings (photographs in museums, scans from books or images from the Google Art Project. To the best of our knowledge, this study is the first to investigate the relation between frames and paintings by measuring physically defined, higher-order image properties.

  1. Atomic Oxygen Treatment as a Method of Recovering Smoke Damaged Paintings

    Science.gov (United States)

    Rutledge, Sharon K.; Banks, Bruce A.; Forkapa, Mark; Stueber, Thomas; Sechkar, Edward; Malinowski, Kevin

    1998-01-01

    Smoke damage, as a result of a fire, can be difficult to remove from some types of painting media without causing swelling, leaching or pigment movement or removal. A non-contact technique has been developed which can remove soot from the surface of a painting by use of a gently flowing gas containing atomic oxygen. The atomic oxygen chemically reacts with the soot on the surface creating gasses such as carbon monoxide and carbon dioxide which can be removed through the use of an exhaust system. The reaction is limited to the surface so that the process can be timed to stop when the paint layer is reached. Atomic oxygen is a primary component of the low Earth orbital environment, but can be generated on Earth through various methods. This paper will discuss the results of atomic oxygen treatment of soot exposed acrylic gesso, ink on paper, and a varnished oil painting. Reflectance measurements were used to characterize the surfaces before and after treatment.

  2. Examination of lead concentrations in new decorative enamel paints in four countries with different histories of activity in lead paint regulation

    International Nuclear Information System (INIS)

    Clark, C. Scott; Kumar, Abhay; Mohapatra, Piyush; Rajankar, Prashant; Nycz, Zuleica; Hambartsumyan, Amalia; Astanina, Lydia; Roda, Sandy; Lind, Caroline; Menrath, William; Peng, Hongying

    2014-01-01

    Paints with high lead concentrations (ppm) continue to be sold around the world in many developing countries and those with economies in transition representing a major preventable environmental health hazard that is being increased as the economies expand and paint consumption is increasing. Prior lead paint testing had been performed in Brazil and India and these countries were selected to examine the impact of a new regulatory limit in Brazil and the impact of efforts of non-governmental organizations and others to stop the use of lead compounds in manufacturing paints. Armenia and Kazakhstan, in Central Asia, were selected because no information on lead concentration in those regions was available, no regulatory activities were evident and non-governmental organizations in the IPEN network were available to participate. Another objective of this research was to evaluate the lead loading (µg/cm 2 ) limit determined by X-Ray Fluorescence (XRF) for areas on toys that are too small to obtain a sample of sufficient size for laboratory analysis. The lead concentrations in more than three-fourths of the paints from Armenia and Kazakhstan exceeded 90 ppm, the limit in the United States, and 600 ppm, the limit in Brazil. The percentages were about one-half as high in Brazil and India. The average concentration in paints purchased in Armenia, 25,000 ppm, is among the highest that has been previously reported, that in Kazakhstan, 15,700 ppm, and India, 16,600, about median. The average concentration in Brazil, 5600 ppm, is among the lowest observed. Paints in Brazil that contained an average of 36,000 ppm before the regulatory limit became effective were below detection (<9 ppm) in samples collected in the current study. The lack of any apparent public monitoring of paint lead content as part of regulatory enforcement makes it difficult to determine whether the regulation was a major factor contributing to the decline in lead use in these paints. Using data from the

  3. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  4. Study of molecular iodine-epoxy paint mass transfer

    Energy Technology Data Exchange (ETDEWEB)

    Belval-Haltier, E [Inst. de Protection et Surete Nucleaire, IPSN, CEN Cadarache, St. Paul-lez-Durance (France)

    1996-12-01

    The mass transfer phenomena may have a significant influence on the quantity of I{sub 2} which could be released following a severe accident of a nuclear power plant and specially the mass transfer of iodine onto containment surfaces. So, the objective of the present work was to evaluate which phase limited the adsorption process of iodine onto gaseous epoxy paint under a range of conditions which may be relevant to a severe reactor accident. In this aim, a series of experiments was conducted in which the sorption kinetics of molecular iodine, labelled with {sup 131}I, was measured by monitoring continuously the accumulation of this species on the epoxy surface. For each test condition, the initial deposition velocity was determined and the corresponding gas phase mass transfer, kg, was estimated by using the heat transfer analogy for a laminar flow passing over a flat plate. Then, the surface reaction rate, Kr, was deduced from these two values. Experiments performed indicated that iodine adsorption onto epoxy paint is highly dependent on temperature, relative humidity of the carrier gas and moisture content of the painted coupon. In dry air flow conditions, the adsorption of iodine onto paint was found to increase with temperature and to be limited by the surface reaction rate, Kr. The I{sub 2} adsorption rate was found to increase with the humidity of carrier gas and in some studied conditions, the initial deposition velocity appeared to be controlled by gas phase mass transfer rather than surface interaction. The same phenomenon has been observed with an increase of the initial water content of the painted coupon. (author) 6 figs., 1 tab., 8 refs.

  5. Evoked Pressure Pain Sensitivity Is Associated with Differential Analgesic Response to Verum and Sham Acupuncture in Fibromyalgia.

    Science.gov (United States)

    Zucker, Noah A; Tsodikov, Alex; Mist, Scott D; Cina, Stephen; Napadow, Vitaly; Harris, Richard E

    2017-08-01

    Fibromyalgia is a chronic pain condition with few effective treatments. Many fibromyalgia patients seek acupuncture for analgesia; however, its efficacy is limited and not fully understood. This may be due to heterogeneous pathologies among participants in acupuncture clinical trials. We hypothesized that pressure pain tenderness would differentially classify treatment response to verum and sham acupuncture in fibromyalgia patients. Baseline pressure pain sensitivity at the thumbnail at baseline was used in linear mixed models as a modifier of differential treatment response to sham versus verum acupuncture. Similarly, needle-induced sensation was also analyzed to determine its differential effect of treatment on clinical pain. A cohort of 114 fibromyalgia patients received baseline pressure pain testing and were randomized to either verum (N = 59) or sham (N = 55) acupuncture. Participants received treatments from once a week to three times a week, increasing in three-week blocks for a total of 18 treatments. Clinical pain was measured on a 101-point visual analog scale, and needle sensation was measured by questionnaire throughout the trial. Participants who had higher pain pressure thresholds had greater reduction in clinical pain following verum acupuncture while participants who had lower pain pressure thresholds showed better analgesic response to sham acupuncture. Moreover, patients with lower pressure pain thresholds had exacerbated clinical pain following verum acupuncture. Similar relationships were observed for sensitivity to acupuncture needling. These findings suggest that acupuncture efficacy in fibromyalgia may be underestimated and a more personalized treatment for fibromyalgia may also be possible. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. A method to measure paddle and detector pressures and footprints in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter; Szczepura, Katy [University of Salford, Salford, Greater Manchester M6 6PU (United Kingdom); Darlington, Alison [Pennine Acute Hospital NHS Trust, Manchester M8 5RB (United Kingdom); Maxwell, Anthony [Royal Bolton Hospital NHS Foundation Trust, Bolton BL4 0JR (United Kingdom)

    2013-04-15

    Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF). No information exists within the literature to describe how pressure balancing between IR and paddle, and IR breast footprint, might be optimized. This paper describes a novel method for measuring the respective pressures applied to the breast from the IR and the paddle and a method to simultaneously measure the breast footprints on the IR and the paddle. Methods: Using a deformable breast phantom and electronic pressure-sensitive mat, area and pressure readings were gathered from two mammography machines and four paddles at 60, 80, and 100 N with the IR positioned at -2, -1, 0, +1, and +2 cm relative to the IMF (60 combinations in total). Results: Paddle and IR footprints were calculated along with a uniformity index (UI). For all four paddle/machine/pressure combinations the greatest IR footprint was achieved at IMF +2 cm. The UI indicates that the best pressure/footprint balance is achieved at IMF +1 cm. Conclusions: The authors' method appears to be suited to measuring breast footprints and pressures on IR and paddle and a human female study is planned.

  7. A method to measure paddle and detector pressures and footprints in mammography

    International Nuclear Information System (INIS)

    Hogg, Peter; Szczepura, Katy; Darlington, Alison; Maxwell, Anthony

    2013-01-01

    Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF). No information exists within the literature to describe how pressure balancing between IR and paddle, and IR breast footprint, might be optimized. This paper describes a novel method for measuring the respective pressures applied to the breast from the IR and the paddle and a method to simultaneously measure the breast footprints on the IR and the paddle. Methods: Using a deformable breast phantom and electronic pressure-sensitive mat, area and pressure readings were gathered from two mammography machines and four paddles at 60, 80, and 100 N with the IR positioned at −2, −1, 0, +1, and +2 cm relative to the IMF (60 combinations in total). Results: Paddle and IR footprints were calculated along with a uniformity index (UI). For all four paddle/machine/pressure combinations the greatest IR footprint was achieved at IMF +2 cm. The UI indicates that the best pressure/footprint balance is achieved at IMF +1 cm. Conclusions: The authors’ method appears to be suited to measuring breast footprints and pressures on IR and paddle and a human female study is planned.

  8. Water-Based Automobile Paints Potentially Reduce the Exposure of Refinish Painters to Toxic Metals

    Directory of Open Access Journals (Sweden)

    Der-Jen Hsu

    2018-05-01

    Full Text Available Exposure to lead-containing dusts is a global public health concern. This work addresses an important issue of whether eco-friendly water-based paints reduce the exposure potential of auto-repainting workers to metals. With this aim, metal levels in automobile paints and worker metal exposure were measured using both solvent- and water-based paints. The levels of metals, and particularly Pb, Cr (total, Fe, and Cu, in solvent-based paints varied greatly among colors and brands. Lead concentrations ranged from below the detection limit (~0.25 μg/g to 107,928 μg/g (dry film across all samples. In water-based paints, the concentrations of Pb and Cr (total were generally two to three orders of magnitude lower, but the concentrations of Al and Cu exceeded those in some solvent-based paints. The personal short-term exposure of workers who applied water-based paints of popular colors, such as black and white, were generally low, with Pb levels of less than <4 µg/m3 and Cr (total levels of less than 1 µg/m3. Conversely, mean short-term exposure to Pb during the painting of a yellow cab using solvent-based paints were 2028 µg/m3, which was ~14 times the Taiwan short-term permissible exposure limit, while the mean level of exposure to Cr (total was 290 µg/m3, which was well below the exposure limit. This study demonstrates that water-based paints reduce the exposure potential to lead, and highlights the importance of source control in limiting the toxic metals in paints.

  9. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  10. Painting Reproductions on Display

    Directory of Open Access Journals (Sweden)

    Joanna Iranowska

    2017-09-01

    Full Text Available Paintings in museums might occasionally be replaced by a photoprint mimicking the original. This article is an investigation of what constitutes a good reproduction of an artwork (oil painting that is meant to be displayed. The article discusses what the usefulness of reproductions depends on, applying the Valuation Studies approach, which means the primary concern is with the practice of valuing itself. In other words, the study focuses on how museum experts evaluate reproduc-tions of oil paintings. The article analyses three cases of displaying digitally prin-ted copies of Edvard Munch's oil paintings between 2013 and 2015 in the Munch Museum and in the National Gallery in Oslo. The study is based on a series of semi-structured interviews with the experts, working at and for the museums, that were involved in producing and exhibiting of the photoprints: curators, con-servators, museum educators, and external manufacturers. The interviews were grouped into five clusters, which I have chosen to call registers of valuing following Frank Heuts and Annemarie Mol (2013. The described valuation practices have to do with delivering experiences to the public, obtaining mimetic resemblance, solving ethical aspects, exhibitions' budget, and last but not least, with the time perspective.

  11. Processing of antifouling paint particles by Mytilus edulis

    International Nuclear Information System (INIS)

    Turner, Andrew; Barrett, Mark; Brown, Murray T.

    2009-01-01

    Particles of spent antifouling paint collected from a marine boatyard were ground and subsequently administered to the filter-feeding bivalve, Mytilus edulis, maintained in static aquaria. Concentrations of Cu and Zn were measured in seawater throughout a 16 h feeding phase and a 24 h depuration phase, in rejected and egested particles collected during the respective phases, and in the organisms themselves at the end of the experiments. Concentrations and distributions of Cu and Zn in processed particles indicated that M. edulis was able to ingest paint particles, regardless of whether nutritionally viable silt was present, and no mechanism of particle discrimination was evident. Enrichment of Cu and Zn in the visceral mass of individuals and in the aqueous phase during depuration supported these assertions, although elevated concentrations in other compartments of the organism (e.g. shell, gill) suggested that biotic and abiotic uptake of aqueous metal was also important. - Particles of antifouling paint enriched in Cu and Zn are ingested and digested by the marine bivalve M. edulis

  12. Processing of antifouling paint particles by Mytilus edulis

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Andrew [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)], E-mail: aturner@plymouth.ac.uk; Barrett, Mark [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Brown, Murray T. [School of Biological Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2009-01-15

    Particles of spent antifouling paint collected from a marine boatyard were ground and subsequently administered to the filter-feeding bivalve, Mytilus edulis, maintained in static aquaria. Concentrations of Cu and Zn were measured in seawater throughout a 16 h feeding phase and a 24 h depuration phase, in rejected and egested particles collected during the respective phases, and in the organisms themselves at the end of the experiments. Concentrations and distributions of Cu and Zn in processed particles indicated that M. edulis was able to ingest paint particles, regardless of whether nutritionally viable silt was present, and no mechanism of particle discrimination was evident. Enrichment of Cu and Zn in the visceral mass of individuals and in the aqueous phase during depuration supported these assertions, although elevated concentrations in other compartments of the organism (e.g. shell, gill) suggested that biotic and abiotic uptake of aqueous metal was also important. - Particles of antifouling paint enriched in Cu and Zn are ingested and digested by the marine bivalve M. edulis.

  13. MEMS Technology Sensors as a More Advantageous Technique for Measuring Foot Plantar Pressure and Balance in Humans

    Directory of Open Access Journals (Sweden)

    Clara Sanz Morère

    2016-01-01

    Full Text Available Locomotor activities are part and parcel of daily human life. During walking or running, feet are subjected to high plantar pressure, leading sometimes to limb problems, pain, or foot ulceration. A current objective in foot plantar pressure measurements is developing sensors that are small in size, lightweight, and energy efficient, while enabling high mobility, particularly for wearable applications. Moreover, improvements in spatial resolution, accuracy, and sensitivity are of interest. Sensors with improved sensing techniques can be applied to a variety of research problems: diagnosing limb problems, footwear design, or injury prevention. This paper reviews commercially available sensors used in foot plantar pressure measurements and proposes the utilization of pressure sensors based on the MEMS (microelectromechanical systems technique. Pressure sensors based on this technique have the capacity to measure pressure with high accuracy and linearity up to high pressure levels. Moreover, being small in size, they are highly suitable for this type of measurement. We present two MEMS sensor models and study their suitability for the intended purpose by performing several experiments. Preliminary results indicate that the sensors are indeed suitable for measuring foot plantar pressure. Importantly, by measuring pressure continuously, they can also be utilized for body balance measurements.

  14. Zinc, Paint loss and Harmony in blue

    DEFF Research Database (Denmark)

    Vila, Anna; Krarup Andersen, Cecil; Baadsgaard, Elizabeth

    2016-01-01

    P.S. Krøyer’s late and most popular paintings have proven very difficult to preserve, and as zinc white has been known to cause structural problems in paintings, the authors investigate if the damage seen in the late paintings can be related to the use of this relatively new pigment. Eight painti...

  15. Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 khz.

    Science.gov (United States)

    Zuckerwar, Allan J; Herring, G C; Elbing, Brian R

    2006-01-01

    A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.

  16. Pressurized thermal shock probabilistic fracture mechanics sensitivity analysis for Yankee Rowe reactor pressure vessel

    International Nuclear Information System (INIS)

    Dickson, T.L.; Cheverton, R.D.; Bryson, J.W.; Bass, B.R.; Shum, D.K.M.; Keeney, J.A.

    1993-08-01

    The Nuclear Regulatory Commission (NRC) requested Oak Ridge National Laboratory (ORNL) to perform a pressurized-thermal-shock (PTS) probabilistic fracture mechanics (PFM) sensitivity analysis for the Yankee Rowe reactor pressure vessel, for the fluences corresponding to the end of operating cycle 22, using a specific small-break-loss- of-coolant transient as the loading condition. Regions of the vessel with distinguishing features were to be treated individually -- upper axial weld, lower axial weld, circumferential weld, upper plate spot welds, upper plate regions between the spot welds, lower plate spot welds, and the lower plate regions between the spot welds. The fracture analysis methods used in the analysis of through-clad surface flaws were those contained in the established OCA-P computer code, which was developed during the Integrated Pressurized Thermal Shock (IPTS) Program. The NRC request specified that the OCA-P code be enhanced for this study to also calculate the conditional probabilities of failure for subclad flaws and embedded flaws. The results of this sensitivity analysis provide the NRC with (1) data that could be used to assess the relative influence of a number of key input parameters in the Yankee Rowe PTS analysis and (2) data that can be used for readily determining the probability of vessel failure once a more accurate indication of vessel embrittlement becomes available. This report is designated as HSST report No. 117

  17. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube (SWCNT)/alginate hydrogel spheres is reported. Conductive and piezoresistive spheres are embedded between conductive electrodes (indium tin oxide-coated polyethylene terephthalate films) and subjected to environmental pressure. The detection mechanism is based on the piezoresistivity of the SWCNT/alginate conductive spheres and on the sphere-electrode contact. Step-by-step, we optimized the design parameters to maximize the sensitivity of the sensor. The optimized hydrogel sensor exhibited a satisfactory sensitivity (0.176 ΔR/R0/kPa-1) and a low detectable limit (10 Pa). Moreover, a brief response time (a few milliseconds) and successful repeatability were also demonstrated. Finally, the efficiency of this strategy was verified through a series of practical tests such as monitoring human wrist pulse, detecting throat muscle motion or identifying the location and the distribution of an external pressure using an array sensor (4 × 4). © 2015 The Royal Society of Chemistry.

  18. Uncertainty and sensitivity analysis of parameters affecting water hammer pressure wave behaviour

    International Nuclear Information System (INIS)

    Kaliatka, A.; Uspuras, E.; Vaisnoras, M.

    2006-01-01

    Pressure surges occurring in pipeline systems may be caused by fast control interference, start up and shut down processes and operation failure. They lead to water hammer upstream the closing valve and cavitational hammer downstream the valve, which may cause considerable damages to the pipeline and the support structures. Appearance of water hammer in thermal-hydraulic systems was widely studied employing different state-of-the-art thermal-hydraulic codes in many organizations. For the analysis water hammer test performed at Fraunhofer Institute for Environmental, Safety and Energy Technology (UMSICHT) at Oberhausen was considered. This paper presents the comparison of UMSICHT test facility experiment calculations employing the best estimate system code RELAP5/Mod3.3 to measured water hammer values after fast closure of a valve. The analysis revealed that the calculated first pressure peak, which has the highest value, matches the measured value very well. The performed analysis (as well as any other analyses) as a results of each individual calculation always contains uncertainty owing to initial conditions of installations, errors of measuring systems, errors caused by nodalization of objects at modelling, code correlations, etc. In this connection, results of uncertainty and sensitivity analysis of the initial conditions and code-selected models are shown in the paper. (orig.)

  19. Commentary on differential-pressure measurements at high reference pressures

    International Nuclear Information System (INIS)

    Hasbrouck, R.T.; Noyes, R.P.

    1981-01-01

    Some practical approaches to the difficult problems in calibrating and implementing differential-pressure measurements are discussed. The data presented were gathered several years ago in separate investigations. An attempt is made to compare the results of these investigations to the common mode concept as described by Peter K. Stein in his publication, The Measurement of Differential Quantities - Problems and Approaches. Although one of these investigations involed a 10,000- to 20,000-psi reference-pressure gas measured at an ambient temperature and the other a classic /sup Δ/P flow measurement of cryogenic temperature, the problems encountered were the same

  20. A transparent bending-insensitive pressure sensor

    Science.gov (United States)

    Lee, Sungwon; Reuveny, Amir; Reeder, Jonathan; Lee, Sunghoon; Jin, Hanbit; Liu, Qihan; Yokota, Tomoyuki; Sekitani, Tsuyoshi; Isoyama, Takashi; Abe, Yusuke; Suo, Zhigang; Someya, Takao

    2016-05-01

    Measuring small normal pressures is essential to accurately evaluate external stimuli in curvilinear and dynamic surfaces such as natural tissues. Usually, sensitive and spatially accurate pressure sensors are achieved through conformal contact with the surface; however, this also makes them sensitive to mechanical deformation (bending). Indeed, when a soft object is pressed by another soft object, the normal pressure cannot be measured independently from the mechanical stress. Here, we show a pressure sensor that measures only the normal pressure, even under extreme bending conditions. To reduce the bending sensitivity, we use composite nanofibres of carbon nanotubes and graphene. Our simulations show that these fibres change their relative alignment to accommodate bending deformation, thus reducing the strain in individual fibres. Pressure sensitivity is maintained down to a bending radius of 80 μm. To test the suitability of our sensor for soft robotics and medical applications, we fabricated an integrated sensor matrix that is only 2 μm thick. We show real-time (response time of ∼20 ms), large-area, normal pressure monitoring under different, complex bending conditions.

  1. An investigation of the neural substrates of mind wandering induced by viewing traditional Chinese landscape paintings

    Directory of Open Access Journals (Sweden)

    Tingting eWang

    2015-01-01

    Full Text Available The present study was conducted to investigate whether the calming effect induced by viewing traditional Chinese landscape paintings would make disengagement from that mental state more difficult, as measured by performance on a cognitive control task. In Experiment 1 we examined the subjective experience of viewing traditional Chinese landscape paintings vs. realistic oil landscape paintings in a behavioral study. Our results confirmed that, as predicted, traditional Chinese landscape paintings induce greater levels of relaxation and mind wandering and lower levels of object-oriented absorption and recognition, compared to realistic oil landscape paintings. In Experiment 2 we used functional Magnetic Resonance Imaging (fMRI to explore the behavioural and neural effects of viewing traditional Chinese landscape paintings on a task requiring cognitive control (i.e., the flanker task—administered immediately following exposure to paintings. Contrary to our prediction, the behavioural data demonstrated that compared to realistic oil landscape paintings, exposure to traditional Chinese landscape paintings had no effect on performance on the flanker task. However, the neural data demonstrated an interaction effect such that there was greater activation in the inferior parietal cortex (IPC and the superior frontal gyrus (SFG on incongruent compared with congruent flanker trials when participants switched from viewing traditional Chinese landscape paintings to the flanker task than when they switched from realistic oil landscape paintings. These results suggest that switching from traditional Chinese landscape paintings placed greater demands on the brain’s attention and working memory networks during the flanker task than did switching from realistic oil landscape paintings.

  2. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong; Mulle, Matthieu; Ventura, Isaac Aguilar; Lubineau, Gilles

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube

  3. Paint Scaler. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    2000-01-01

    The Paint Scaler can collect paint samples quickly and efficiently for lab analysis. The Rotary Hammer Drill is a 24-V battery operated, 3/4-in. rotary hammer drill. When used with an optional chipping adapter, the Bosch Rotary Hammer Drill can be used to perform chipping and chiseling tasks such as paint removal from either concrete or metal surfaces. It is ultra-compact, lightweight with an ergonomic balanced grip. The battery operation gives the operator more flexibility during sampling activities

  4. Self-training-based spectral image reconstruction for art paintings with multispectral imaging.

    Science.gov (United States)

    Xu, Peng; Xu, Haisong; Diao, Changyu; Ye, Zhengnan

    2017-10-20

    A self-training-based spectral reflectance recovery method was developed to accurately reconstruct the spectral images of art paintings with multispectral imaging. By partitioning the multispectral images with the k-means clustering algorithm, the training samples are directly extracted from the art painting itself to restrain the deterioration of spectral estimation caused by the material inconsistency between the training samples and the art painting. Coordinate paper is used to locate the extracted training samples. The spectral reflectances of the extracted training samples are acquired indirectly with a spectroradiometer, and the circle Hough transform is adopted to detect the circle measuring area of the spectroradiometer. Through simulation and a practical experiment, the implementation of the proposed method is explained in detail, and it is verified to have better reflectance recovery performance than that using the commercial target and is comparable to the approach using a painted color target.

  5. Epidermis Microstructure Inspired Graphene Pressure Sensor with Random Distributed Spinosum for High Sensitivity and Large Linearity.

    Science.gov (United States)

    Pang, Yu; Zhang, Kunning; Yang, Zhen; Jiang, Song; Ju, Zhenyi; Li, Yuxing; Wang, Xuefeng; Wang, Danyang; Jian, Muqiang; Zhang, Yingying; Liang, Renrong; Tian, He; Yang, Yi; Ren, Tian-Ling

    2018-03-27

    Recently, wearable pressure sensors have attracted tremendous attention because of their potential applications in monitoring physiological signals for human healthcare. Sensitivity and linearity are the two most essential parameters for pressure sensors. Although various designed micro/nanostructure morphologies have been introduced, the trade-off between sensitivity and linearity has not been well balanced. Human skin, which contains force receptors in a reticular layer, has a high sensitivity even for large external stimuli. Herein, inspired by the skin epidermis with high-performance force sensing, we have proposed a special surface morphology with spinosum microstructure of random distribution via the combination of an abrasive paper template and reduced graphene oxide. The sensitivity of the graphene pressure sensor with random distribution spinosum (RDS) microstructure is as high as 25.1 kPa -1 in a wide linearity range of 0-2.6 kPa. Our pressure sensor exhibits superior comprehensive properties compared with previous surface-modified pressure sensors. According to simulation and mechanism analyses, the spinosum microstructure and random distribution contribute to the high sensitivity and large linearity range, respectively. In addition, the pressure sensor shows promising potential in detecting human physiological signals, such as heartbeat, respiration, phonation, and human motions of a pushup, arm bending, and walking. The wearable pressure sensor array was further used to detect gait states of supination, neutral, and pronation. The RDS microstructure provides an alternative strategy to improve the performance of pressure sensors and extend their potential applications in monitoring human activities.

  6. A sensitive pressure sensor for diamond anvil cell experiments up to 2 GPa: FluoSpheres[reg

    International Nuclear Information System (INIS)

    Picard, Aude; Oger, Phil M.; Daniel, Isabelle; Cardon, Herve; Montagnac, Gilles; Chervin, Jean-Claude

    2006-01-01

    We present an optical pressure sensor suitable for experiments in diamond anvil cell in the 0.1 MPa-2 GPa pressure range, for temperatures between ambient and 323 K. It is based on the pressure-dependent fluorescence spectrum of FluoSpheres[reg], which are commercially available fluorescent microspheres commonly used to measure blood flow in experimental biology. The fluorescence of microspheres is excited by the 514.5 nm line of an Ar + laser, and the resulting spectrum displays three very intense broad bands at 534, 558, and 598 nm, respectively. The reference wavelength and pressure gauge is that of the first inflection point of the spectrum, located at 525.6±0.2 nm at ambient pressure. It is characterized by an instantaneous and large linear pressure shift of 9.93(±0.08) nm/GPa. The fluorescence of the FluoSpheres[reg] has been investigated as a function of pressure (0.1-4 GPa), temperature (295-343 K), pH (3-12), salinity, and pressure transmitting medium. These measurements show that, for pressures comprised between 0.1 MPa and 2 GPa, at temperatures not exceeding 323 K, at any pH, in aqueous pressure transmitting media, pressure can be calculated from the wavelength shift of two to three beads, according to the relation P=0.100 (±0.001) Δλ i (P) with Δλ i (P)=λ i (P)-λ i (0) and λ i (P) as the wavelength of the first inflection point of the spectrum at the pressure P. This pressure sensor is approximately thirty times more sensitive than the ruby scale and responds instantaneously to pressure variations

  7. Environment sensitive cracking in light water reactor pressure boundary materials

    International Nuclear Information System (INIS)

    Haenninen, H.; Aho-Mantila, I.

    1985-01-01

    The purpose of the paper is to review the available methods and the most promising future possibilities of preventive maintenance to counteract the various forms of environment sensitive cracking of pressure boundary materials in light water reactors. Environment sensitive cracking is considered from the metallurgical, mechanical and environmental point of view. The main emphasis is on intergranular stress corrosion cracking of austenitic stainless steels and high strenght Ni-base alloys, as well as on corrosion fatigue of low alloy and stainless steels. Finally, some general ideas how to predict, reduce or eliminate environment sensitive cracking in service are presented

  8. Examination of lead concentrations in new decorative enamel paints in four countries with different histories of activity in lead paint regulation

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. Scott, E-mail: clarkcs@ucmail.uc.edu [Department of Environmental Health, University of Cincinnati (United States); International POPS Elimination Network (IPEN), San Francisco (United States); Kumar, Abhay; Mohapatra, Piyush; Rajankar, Prashant [Toxics Link, New Delhi (India); Nycz, Zuleica [APROMAC Environmental Protection Association and Toxisphera Environmental Health Association, Curitiba, Parana (Brazil); Hambartsumyan, Amalia [Greenwomen, Almaty (Kazakhstan); Astanina, Lydia [Khazer Ecological and Cultural Non-Governmental Organization, Yerevan (Armenia); Roda, Sandy; Lind, Caroline; Menrath, William; Peng, Hongying [Department of Environmental Health, University of Cincinnati (United States)

    2014-07-15

    Paints with high lead concentrations (ppm) continue to be sold around the world in many developing countries and those with economies in transition representing a major preventable environmental health hazard that is being increased as the economies expand and paint consumption is increasing. Prior lead paint testing had been performed in Brazil and India and these countries were selected to examine the impact of a new regulatory limit in Brazil and the impact of efforts of non-governmental organizations and others to stop the use of lead compounds in manufacturing paints. Armenia and Kazakhstan, in Central Asia, were selected because no information on lead concentration in those regions was available, no regulatory activities were evident and non-governmental organizations in the IPEN network were available to participate. Another objective of this research was to evaluate the lead loading (µg/cm{sup 2}) limit determined by X-Ray Fluorescence (XRF) for areas on toys that are too small to obtain a sample of sufficient size for laboratory analysis. The lead concentrations in more than three-fourths of the paints from Armenia and Kazakhstan exceeded 90 ppm, the limit in the United States, and 600 ppm, the limit in Brazil. The percentages were about one-half as high in Brazil and India. The average concentration in paints purchased in Armenia, 25,000 ppm, is among the highest that has been previously reported, that in Kazakhstan, 15,700 ppm, and India, 16,600, about median. The average concentration in Brazil, 5600 ppm, is among the lowest observed. Paints in Brazil that contained an average of 36,000 ppm before the regulatory limit became effective were below detection (<9 ppm) in samples collected in the current study. The lack of any apparent public monitoring of paint lead content as part of regulatory enforcement makes it difficult to determine whether the regulation was a major factor contributing to the decline in lead use in these paints. Using data from the

  9. Sanding dust from nanoparticle-containing paints: Physical characterisation

    International Nuclear Information System (INIS)

    Koponen, I K; Jensen, K A; Schneider, T

    2009-01-01

    Increasing use of nanoparticles in different industrial applications has raised a new potential health risk to the workers as well as to the consumers. This study investigates the particle size distributions of sanding dust released from paints produced with and without engineered nanoparticles. Dust emissions from sanding painted plates were found to consist of five size modes; three modes under 1 μm and two modes around 1 and 2 μm. We observed that the sander was the only source of particles smaller than 50 nm and they dominated the number concentration spectra. Mass and surface area spectra were dominated by the 1 and 2 μm modes. Addition of nanoparticles caused only minor changes in the geometric mean diameters of the particle modes generated during sanding of two paints doped with 17 nm TiO2 and 95 nm Carbon Black nanoparticles as compared to the size modes generated during sanding a conventional reference paint. However, the number concentrations in the different size modes varied considerably in between the two NP-doped paints and the reference paint. Therefore, from a physical point of view, there may be a difference in the exposure risk during sanding surfaces covered with nanoparticle-based paints as compared to sanding conventional paints.

  10. Novel highly sensitive and wearable pressure sensors from conductive three-dimensional fabric structures

    International Nuclear Information System (INIS)

    Li, Jianfeng; Xu, Bingang

    2015-01-01

    Pressure sensors based on three-dimensional fabrics have all the excellent properties of the textile substrate: excellent compressibility, good air permeability and moisture transmission ability, which will find applications ranging from the healthcare industry to daily usage. In this paper, novel pressure sensors based on 3D spacer fabrics have been developed by a proposed multi-coating method. By this coating method, carbon black can be coated uniformly on the silicon elastomer which is attached and slightly cured on the 3D fabric surface beforehand. The as-made pressure sensors have good conductivity and can measure external pressure up to 283 kPa with an electrical conductivity range of 9.8 kΩ. The sensitivity of 3D fabric pressure sensors can be as high as 50.31×10 −3 kPa −1 , which is better than other textile based pressure sensors. When the as-made sensors are pressed, their electrical resistance will decrease because of more conductive connections and bending of fibers in the spacer layer. The sensing mechanism related to fiber bending has been explored by using an equivalent resistance model. The newly developed 3D sensor devices can be designed to exhibit different sensing performances by simply changing the structures of fabric substrate, which endows this kind of device more flexibility in related applications. (paper)

  11. Nanoparticles Ni electroplating and black paint for solar collector applications

    Directory of Open Access Journals (Sweden)

    J. El Nady

    2016-06-01

    Full Text Available A nanoparticles layer of bright nickel base was deposited on copper substrates using electrodeposition technique before spraying the paint. IR reflectance of the paint was found to be around 0.4 without bright nickel layer and the reflectance increased to 0.6 at a Ni layer thickness of 750 nm. The efficiency of the constructed solar collectors using black paint and black paint combined with bright nickel was found to be better than black paint individually. After aging tests under high temperature, Bright nickel improved the stability of the absorber paint. The collector optical gain FR(τα was lowered by 24.7% for the commercial paint and lowered by 19.3% for the commercial paint combined with bright nickel. The overall heat loss FR(UL was increased by 3.3% for the commercial paint and increased by 2.7% for the commercial paint combined with bright nickel after the temperature aging test.

  12. Sensitivity enhancement using annealed polymer optical fibre based sensors for pressure sensing applications

    DEFF Research Database (Denmark)

    Pospori, A.; Marques, C. A. F.; Saez-Rodriguez, D.

    2016-01-01

    for that investigation was an unexpected behaviour observed in an array of sensors which were used for liquid level monitoring. One sensor exhibited much lower pressure sensitivity and that was the only one that was not annealed. To further investigate the phenomenon, additional sensors were photo...... sensitivity of the devices. This can provide better performing sensors for use in stress, force and pressure sensing applications.......Thermal annealing can be used to induce a permanent negative Bragg wavelength shift for polymer fibre grating sensors and it was originally used for multiplexing purposes. Recently, researchers showed that annealing can also provide additional benefits, such as strain and humidity sensitivity...

  13. Electrochemical Decontamination of Painted and Heavily Corroded Metals

    International Nuclear Information System (INIS)

    Marczak, S.; Anderson, J.; Dziewinski, J.

    1998-01-01

    The radioactive metal wastes that are generated from nuclear fuel plants and radiochemical laboratories are mainly contaminated by the surface deposition of radioactive isotopes. There are presently several techniques used in removing surface contamination involving physical and chemical processes. However, there has been very little research done in the area of soiled, heavily oxidized, and painted metals. Researchers at Los Alamos National Laboratory have been developing electrochemical procedures for the decontamination of bare and painted metal objects. These methods have been found to be effective on highly corroded as well as relatively new metals. This study has been successful in decontaminating projectiles and shrapnel excavated during environmental restoration projects after 40+ years of exposure to the elements. Heavily corroded augers used in sampling activities throughout the area were also successfully decontaminated. This process has demonstrated its effectiveness and offers several advantages over the present metal decontamination practices of media blasting and chemical solvents. These advantages include the addition of no toxic or hazardous chemicals, low operating temperature and pressure, and easily scaleable equipment. It is in their future plans to use this process in the decontamination of gloveboxes destined for disposal as TRU waste

  14. 24 CFR 35.135 - Use of paint containing lead.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead. (a...

  15. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  16. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  17. Retrospective dosimetry using chromosome painting

    International Nuclear Information System (INIS)

    Nasazzi, N.B.; Giorgio, M.D.; Taja, M.R.

    2000-01-01

    Chromosome aberration frequency measured in peripheral lymphocytes of persons exposed to ionizing radiation has been used since 1960s for dose assessment. Suspected overexposure is usually evaluated by the frequency of dicentrics and centric rings using an appropriate in vitro calibration curve. However, these chromosome aberrations are unstable with time after exposure and dose reconstruction may encounter uncertainties when the time between the exposure and the analysis is considerable or even unknown. It appears that translocations persist with time after exposure and may be used as an indication of acute past overexposures. Moreover, they appear to accumulate the cytogenetical information, which correlates with the dose received under fractionated, chronic or even occupational exposure conditions. Translocations may be detected using G-banding, which allows to score the total amount of radiation induced translocations but it is a time consuming method, or by Chromosome Painting, a method base on the Fluorescence in situ Hybridization (FISH) technique, painting only some chromosome pairs with specific whole chromosome probes and then extrapolating the observed translocation frequencies to the full genome. The latter method allows a faster aberration scoring than G-banding and appears to be the most promissory tool for biodosimetry, particularly when it is necessary to assess low doses and consequently to score a large number of metaphases, e.g. radiation workers exposed within dose limits. As with the unstable chromosome aberration, it is necessary an in vitro calibration curve based on the frequency of stable chromosome aberrations to assess doses. Our laboratory performed calibration curves for Co 60 γ-rays based on the frequencies of unstable (dicentrics and centric rings detected by conventional Giemsa staining) and stable chromosome aberrations (translocations and inversions, detected by G-banding). In order to minimize the interlaboratory variability, we

  18. Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

    Science.gov (United States)

    Browell, Edward V.; Ismail, Syed; Grossmann, Benoist E.

    1991-01-01

    Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

  19. Fast Neutral Pressure Measurements in NSTX

    International Nuclear Information System (INIS)

    R. Raman; H.W. Kugel; T. Provost; R. Gernhardt; T.R. Jarboe; M.G. Bell

    2002-01-01

    Several fast neutral pressure gauges have been installed on NSTX [National Spherical Torus Experiment] to measure the vessel and divertor pressure during inductive and coaxial helicity injected (CHI) plasma operations. Modified, PDX [Poloidal Divertor Experiment]-type Penning gauges have been installed on the upper and lower divertors. Neutral pressure measurements during plasma operations from these and from two shielded fast Micro ion gauges at different toroidal locations on the vessel mid-plane are described. A new unshielded ion gauge, referred to as the In-vessel Neutral Pressure (INP) gauge is under development

  20. Regulating antifouling paints for leisure boats - a patchwork of rules across three Baltic Sea countries

    DEFF Research Database (Denmark)

    Kymenvaara, Sara; Anker, Helle Tegner; Baaner, Lasse

    2017-01-01

    This article analyses how the use of antifouling paints for leisure boats is regulated in Denmark, Finland and Sweden. All three countries appear to apply a somewhat fragmented approach to the different matters related to antifouling paints, including environmental quality (e.g. water quality...... sufficient measures and conduct. Environmental protection regulation, including waste legislation, generally excludes smaller leisure boat marinas and boat clubs from permitting and waste management requirements. In product regulation, the authorisation and/or restriction rules of antifouling paints...

  1. Radioactive Decontamination by Strippable Paint

    International Nuclear Information System (INIS)

    Chantaraparprachoom, N.; Mishima, K.

    1998-01-01

    The strippable paint, one of the adhesion method, is to decontaminate solid surface of materials or/and a large area. Two kinds of specimen planchet, SUS 304 stainless steel and polycarbonate plastic, contaminated with radioactive 137 Cs were studied under various conditions. It included surface bottom types, the flat and convex concentric circle type, normal condition at room temperature and overheat condition (∼80 degree celsius). This method used coating paints which contains some elements to have a reaction with radioactive materials selectively. ALARA-Decon clear, Rempack-X200 clear, JD-P5-Mrs.Coat and Pro-Blue-color guard were selected to use as the coating paints. The contaminated surface was coated by the strippable paint under the optimum time, followed by peeling the paint seal. The Rempack-X200 showed the best result, the highest decontamination efficiency which are about 99-100% for all conditions of specimens. The JD-P5 and ALARA-Decon showed good results, which are 98-99% decontamination efficiency for the normal condition set of specimens and about 94-97% for the overheat set of specimens. They can decontaminate polycarbonate specimens better than stainless steel specimens. The Pro-Blue-color guard showed the lowest decontamination efficiency of which 60% for polycarbonate specimens at normal condition and 40%, 30% for stainless steel specimens at normal and overheat conditions respectively. There was no effects of surface bottom types significantly

  2. Soluble salts: their incidence on the protection of metallic structures by paint coatings

    International Nuclear Information System (INIS)

    Morcillo, M.

    2003-01-01

    The presence of soluble salts at the metal/paint interface is known to have a detrimental effect on the integrity of most paint systems. Though this is a long-standing problem, it has recently come to receive greater attention from the protective coatings industry. In the paper the following points are reviewed: degradation mechanisms of the metal/paint system, the role of the metallic substrate, the nature, origin and detection os soluble salts, expected levels of soluble salts in practice, critical thresholds of soluble salts and risk levels for premature failures, role of the type and thickness of paint systems and exposure conditions, and prevention measures. The author presents an overview of the subject, making reference to the related research that has been carried out by him and his co-workers over the last 16 years. (Author) 58 refs

  3. Studies on irradiation resisting paints for concrete structures in nuclear power plant, 4

    International Nuclear Information System (INIS)

    Kita, Daizo; Sumino, Masahiro; Goto, Tomoaki.

    1978-01-01

    It is necessary for irradiation resisting paints to adhere tightly to concrete in order to exhibit superior effects. Adhesion of paints to concrete is greatly affected by moisture content and the form of moisture in concrete. Further, adhesion will probably be affected by differences in concrete surface conditions between floors, walls and ceilings. Therefore, experiments were conducted with concrete to make clear allowable moisture conditions and the influence of these concrete surfaces. The following results were obtained. (1) Adhesion of paint becomes stronger as pF-value increases, that is, as moisture content falls. (2) The allowable pF-values and moisture contents were respectively 5.5 over and 4.5% under at floor, 4.4 over and 4.9% under at wall, and 4.3 over and 5% under at ceiling. (3) Fractures of paint films under these allowable conditions occurred in paint-concrete composites, and the fractured concrete thickness than was 0.5-0.8 mm and measured adhesion strength was 33 kg/cm 2 . (auth.)

  4. The physicochemical characterization of cave paintings of Baja California

    International Nuclear Information System (INIS)

    Valdez, B.; Cobo, J.; Schorr, M.; Cota, L.; Oviedo, F.

    2006-01-01

    The Palaeolithic paintings of Baja California constitute an important contribution to the national, historic and cultural patrimony of Mexico. The aim of this investigation was to determine the physicochemical characteristics, the microstructure and texture of these polychrome paintings, painted on rocks encountered in the mountainous, desert/arid zones of Baja California and Baja California South. The first stage of this work was devoted to the examination and recording of the cave paintings of 'El Vallecito', a narrow fluvial valley displaying large granitic rocks emerging from the sandy soil. Tiny painting samples were collected and analyzed by SEM, EDS and FTIR techniques. The painters used four main colours: red, black, yellow and white. The paint raw materials are mineral pigments: white (kaolin, calcite, and gypsum), red (hematite), yellow (ochre, limonite), black (charcoal from burnt wood or calcined bones) and water as a diluent and/or a binder, all encountered in the painters habitat. The minerals were collected, ground and sometimes heated to change their tone. By mixing with water, a spreadable paste or a thick slurry was produced, which was applied with the fingers for lines or a piece of animal skin for figures, respectively. The 100% solids, dry paint converts into a dense, hard layer, incrusted into the grainy, rough, hollow granite rock surface. This paint might be called s tone on stone , explaining its permanence for centuries enduring heat, wind and weather. A simulation of the painting technique was done at the Materials and Corrosion Laboratory, UABC by collecting mineral pigments, preparing the paint as a paste or slurry and applying it on a granitic rock. Knowing the paint composition, production and application techniques will be useful in e conservation and restoration of cave paintings and stone-built, ancient structures such as pyramids, cathedrals and monuments. (Author)

  5. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  6. Sensitivity enhancement of polysilicon piezo-resistive pressure sensors with phosphorous diffused resistors

    International Nuclear Information System (INIS)

    Sivakumar, K; Dasgupta, N; Bhat, K N; Natarajan, K

    2006-01-01

    It is generally accepted that the piezo-resistive coefficient in single crystal silicon is higher when P-type impurities such as boron are used for doping the resistors. In this paper we demonstrate that the sensitivity of polycrystalline silicon piezo-resistive pressure sensors can be enhanced considerably when phosphorus diffusion source is used instead of boron dopant for realizing the piezo-resistors. Pressure sensors have been designed and fabricated with the polycrystalline piezo-resistors connected in the form of a Wheatstone bridge and laid out on thermal oxide grown on membranes obtained with a Silicon On Insulator (SOI) approach. The SOI wafers required for this purpose have been realized in-house by Silicon Fusion Bonding (SFB) and etch back technique in our laboratory. This approach provides excellent isolation between the resistors and enables zero temperature coefficient of the polysilicon resistor. The results obtained in our laboratory have clearly demonstrated that by optimizing the phosphorus diffusion temperature and duration, it is possible to achieve sensitivities in excess of 20mV /Bar for bridge input voltage of 10V, with linearity within 1% over a differential pressure range up to 10Bar (10 6 Pascal), and burst pressure in excess of 50 Bar as compared to the 10mV /Bar sensitivity obtained with boron doped polysilicon piezo-resistors. This enhancement is attributed to grain boundary passivation by phosphorous atoms

  7. Ultraviolet-radiation-curable paints

    Energy Technology Data Exchange (ETDEWEB)

    Grosset, A M; Su, W F.A.; Vanderglas, E

    1981-09-30

    In product finishing lines, ultraviolet radiation curing of paints on prefabricated structures could be more energy efficient than curing by natural gas fired ovens, and could eliminate solvent emission. Diffuse ultraviolet light can cure paints on three dimensional metal parts. In the uv curing process, the spectral output of radiation sources must complement the absorption spectra of pigments and photoactive agents. Photosensitive compounds, such as thioxanthones, can photoinitiate unsaturated resins, such as acrylated polyurethanes, by a free radical mechanism. Newly developed cationic photoinitiators, such as sulfonium or iodonium salts (the so-called onium salts) of complex metal halide anions, can be used in polymerization of epoxy paints by ultraviolet light radiation. One-coat enamels, topcoats, and primers have been developed which can be photoinitiated to produce hard, adherent films. This process has been tested in a laboratory scale unit by spray coating these materials on three-dimensional objects and passing them through a tunnel containing uv lamps.

  8. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  9. A microwave pressure sounder. [for remote measurement of atmospheric pressure

    Science.gov (United States)

    Peckham, G. E.; Flower, D. A.

    1981-01-01

    A technique for the remote measurement of atmospheric surface pressure will be described. Such measurements could be made from a satellite in polar orbit and would cover many areas for which conventional meteorological data are not available. An active microwave instrument is used to measure the strength of return echoes from the ocean surface at a number of frequencies near the 60 GHz oxygen absorption band. Factors which affect the accuracy with which surface pressure can be deduced from these measurements will be discussed and an instrument designed to test the method by making measurements from an aircraft will be described.

  10. Thermogravimetric measurements of liquid vapor pressure

    International Nuclear Information System (INIS)

    Rong Yunhong; Gregson, Christopher M.; Parker, Alan

    2012-01-01

    Highlights: ► Rapid determination of vapor pressure by TGA. ► Demonstration of limitations of currently available approaches in literature. ► New model for vapor pressure assessment of small size samples in TGA. ► New model accounts for vapor diffusion and sample geometry and measures vapor pressure normally within 10%. - Abstract: A method was developed using thermo-gravimetric analysis (TGA) to determine the vapor pressure of volatile liquids. This is achieved by measuring the rate of evaporation (mass loss) of a pure liquid contained within a cylindrical pan. The influence of factors like sample geometry and vapor diffusion on evaporation rate are discussed. The measurement can be performed across a wide range of temperature yielding reasonable results up to 10 kPa. This approach may be useful as a rapid and automatable method for measuring the volatility of flavor and fragrance raw materials.

  11. 76 FR 27044 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Science.gov (United States)

    2011-05-10

    ..., Repair and Painting, and Pre- Renovation Education Activities in Target Housing and Child Occupied...), and a lead-based paint pre-renovation education program in accordance with section 406(b) of TSCA, 15... renovation and remodeling activities of pre-1978 housing and child-occupied facilities in the State of...

  12. Automotive Painting Technology A Monozukuri-Hitozukuri Perspective

    CERN Document Server

    Salazar, Abraham; Saito, Kozo

    2013-01-01

    This book offers unique and valuable contributions to the field. It offers breadth and inclusiveness. Most existing works on automotive painting cover only a single aspect of this complex topic, such as the chemistry of paint or paint booth technology. Monozukuri and Hitozukuri are Japanese terms that can be translated as “making things” and “developing people” but their implications in Japanese are richer and more complex than this minimal translation would indicate. The Monozukuri-Hitozukuri perspective is drawn from essential principles on which the Toyota approach to problem-solving and continuous improvement is based. From this perspective, neither painting technology R&D nor painting technology use in manufacturing can be done successfully without integrating technological and human concerns involved with making and learning in the broadest sense, as the hyphen is meant to indicate. The editors provide case studies and examples -- drawn from Mr. Toda’s 33 years of experience with automotiv...

  13. Painting with polygons: a procedural watercolor engine.

    Science.gov (United States)

    DiVerdi, Stephen; Krishnaswamy, Aravind; Měch, Radomír; Ito, Daichi

    2013-05-01

    Existing natural media painting simulations have produced high-quality results, but have required powerful compute hardware and have been limited to screen resolutions. Digital artists would like to be able to use watercolor-like painting tools, but at print resolutions and on lower end hardware such as laptops or even slates. We present a procedural algorithm for generating watercolor-like dynamic paint behaviors in a lightweight manner. Our goal is not to exactly duplicate watercolor painting, but to create a range of dynamic behaviors that allow users to achieve a similar style of process and result, while at the same time having a unique character of its own. Our stroke representation is vector based, allowing for rendering at arbitrary resolutions, and our procedural pigment advection algorithm is fast enough to support painting on slate devices. We demonstrate our technique in a commercially available slate application used by professional artists. Finally, we present a detailed analysis of the different vector-rendering technologies available.

  14. The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

    Science.gov (United States)

    Al-Fakih, Ebrahim A; Osman, Noor Azuan Abu; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd

    2013-08-12

    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.

  15. Chromosome painting in biological dosimetry: Semi-automatic system to score stable chromosome aberrations

    International Nuclear Information System (INIS)

    Garcia-Sagredo, J.M.; Vallcorba, I.; Sanchez-Hombre, M.C.; Ferro, M.T.; San Roman Cos-Gayon, C.; Santos, A.; Malpica, N.; Ortiz, C.

    1997-01-01

    From the beginning of the description of the procedure of chromosome painting by fluorescence in situ hybridization (FISH), it was thought its possible application to score induced chromosomal aberrations in radiation exposition. With chromosome painting it is possible to detect changes between chromosomes that has been validated in radiation exposition. Translocation scoring by FISH, contrarily to the unstable dicentrics, mainly detect stable chromosome aberrations that do not disappear, it allows the capability of quantify delayed acute expositions or chronic cumulative expositions. The large number of cells that have to be analyzed for high accuracy, specially when dealing with low radiation doses, makes it almost imperative to use an automatic analysis system. After validate translocation scoring by FISH in our, we have evaluated the ability and sensitivity to detect chromosomal aberrations by chromosome using different paint probes used, showing that any combination of paint probes can be used to score induced chromosomal aberrations. Our group has developed a FISH analysis that is currently being adapted for translocation scoring analysis. It includes systematic error correction and internal control probes. The performance tests carried out show that 9,000 cells can be analyzed in 10 hr. using a Sparc 4/370. Although with a faster computer, a higher throughput is expected, for large population screening or very low radiation doses, this performance still has to be improved. (author)

  16. Imagined memories of painting

    OpenAIRE

    Horta, Maia Schmidt, 1974-

    2011-01-01

    Tese de mestrado, Pintura, Universidade de Lisboa, Faculdade de Belas Artes, 2011 A Tese é compsota por dois volumes, um em portugês, outro em inglês Visual imagery, narratives and locations have always been linked to the study of memory. Memory has always been linked to art history and historical shifts in the study of memory had a direct impact on the history of painting. Painting was based on stories and served to make those stories memorable. Since then there have been numerous inve...

  17. Occupational exposure to airborne chemical substances in paintings conservators

    Directory of Open Access Journals (Sweden)

    Anna Jeżewska

    2014-02-01

    Full Text Available Background: This paper presents the results of the quantitative study of the airborne chemical substances detected in the conservator's work environment. Material and Methods: The quantitative tests were carried out in 6 museum easel paintings conservation studios. The air test samples were taken at various stages of restoration works, such as cleaning, doubling, impregnation, varnishing, retouching, just to name a few. The chemical substances in the sampled air were measured by the GC-FID (gas chromatography with flame ionization detector test method. Results: The study results demonstrated that concentrations of airborne substances, e.g., toluene, 1,4-dioxane, turpentine and white spirit in the work environment of paintings conservators exceeded the values allowed by hygiene standards. It was found that exposure levels to the same chemical agents, released during similar activities, varied for different paintings conservation studios. It is likely that this discrepancy resulted from the indoor air exchange system for a given studio (e.g. type of ventilation and its efficiency, the size of the object under maintenance, and also from the methodology and protection used by individual employees. Conclusions: The levels of organic solvent vapors, present in the workplace air in the course of painting conservation, were found to be well above the occupational exposure limits, thus posing a threat to the worker's health. Med Pr 2014;65(1:33–41

  18. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    Science.gov (United States)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko

    2017-09-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.

  19. Cleaning and Restoration of an Oil Painting with a Polymer Gel in Iran

    Directory of Open Access Journals (Sweden)

    Siyamak Alizadeh

    2018-03-01

    Full Text Available One of the major stages in the conservation and restoration of a painting is to clean its colored surface of unwanted stains, and old and darkened varnishes. Various solvents have been used to date for this purpose; however, new cleaning materials have also come onto the market in the past decade that are still unknown and may never have been employed in Iran. The present study aims to introduce a polymer gel and use an in vitro sample of the substance for cleaning and to then present the results of the tests carried out. Applying a polymer gel in the cleaning of paintings yielded better results and greater advantages over the solvents previously used to clean artworks. The advantages include, performing on the surface without penetrating the lower layers, the absence of residues after application, flexibility, solubility and the gentle removal of old stains and varnishes, maintaining clarity and cleaning the surface by simple removal of the thin dried layer, which requires no mechanical pressure. Microscopic examinations and pH testing showed that this new alternative technique can be of use in cleaning the color layers of oil paintings.

  20. The application of acoustic emission measurements on laboratory testpieces to large scale pressure vessel monitoring

    International Nuclear Information System (INIS)

    Ingham, T.; Dawson, D.G.

    1975-01-01

    A test pressure vessel containing 4 artificial defects was monitored for emission whilst pressure cycling to failure. Testpieces cut from both the failed vessel and from as-rolled plate material were tested in the laboratory. A marked difference in emission characteristics was observed between plate and vessel testpieces. Activity from vessel material was virtually constant after general yield and emission amplitudes were low. Plate testpieces showed maximum activity at general yield and more frequent high amplitude emissions. An attempt has been made to compare the system sensitivities between the pressure vessel test and laboratory tests. In the absence of an absolute calibration device, system sensitivities were estimated using dummy signals generated by the excitation of an emission sensor. The measurements have shown an overall difference in sensitivity between vessel and laboratory tests of approximately 25db. The reduced sensitivity in the vessel test is attributed to a combination of differences in sensors, acoustic couplant, attenuation, and dispersion relative to laboratory tests and the relative significance of these factors is discussed. Signal amplitude analysis of the emissions monitored from laboratory testpieces showed that, whith losses of the order of 25 to 30db, few emissions would be detected from the pressure vessel test. It is concluded that no reliable prediction of acoustic behaviour of a structure may be made from laboratory test unless testpieces of the actual structural material are used. A considerable improvement in detection sensitivity, is also required for reliable detection of defects in low strength ductile materials and an absolute method of system calibration is required between tests

  1. A Short History of the Chemistry of Painting.

    Science.gov (United States)

    Friedstein, Harriet G.

    1981-01-01

    Includes information on: (1) relationship of art and science; (2) paintings' early history; (3) Egyptian, Greek, Chinese, Byzantine, and Medieval painting; (4) chemical analysis of pigments; (5) chemistry of early pigments; and (6) paint media. Tabular data are provided on chemical names for artists' pigments with their earliest known dates. (CS)

  2. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  3. Staicele Paint Manufactory, Ochre Deposit of Reciems: A Retrospective Journey Through the History of Staicele Paint Manufactory and Evaluation of Production Technologies

    Directory of Open Access Journals (Sweden)

    Kokins Aigars

    2017-05-01

    Full Text Available A historical paint manufactory in Staicele, Latvia (1967, was using local resources – colour earth. Oil paint composition consisted of pigment, drying oil, varnish and siccative. It had two different tones that are obtained by using natural colour earth pigments: ochre and its burnt form (burnt umber. Pigment quality was analyzed using historical documents, modern pigment tests, and manufactory technology. Chemical composition, particle size, and pigment tone were determined, and the coating ability was calculated. A palette of oil paints based on the historical recipes for restoring Staicele oil paints was created. Properties of colour earth pigments were compared to specimens taken from the local source of iron that is located near the old paint factory. Results provide a historical and technological insight as well as insight in the properties of the basic paint composition.

  4. Chemically Designed Metallic/Insulating Hybrid Nanostructures with Silver Nanocrystals for Highly Sensitive Wearable Pressure Sensors.

    Science.gov (United States)

    Kim, Haneun; Lee, Seung-Wook; Joh, Hyungmok; Seong, Mingi; Lee, Woo Seok; Kang, Min Su; Pyo, Jun Beom; Oh, Soong Ju

    2018-01-10

    With the increase in interest in wearable tactile pressure sensors for e-skin, researches to make nanostructures to achieve high sensitivity have been actively conducted. However, limitations such as complex fabrication processes using expensive equipment still exist. Herein, simple lithography-free techniques to develop pyramid-like metal/insulator hybrid nanostructures utilizing nanocrystals (NCs) are demonstrated. Ligand-exchanged and unexchanged silver NC thin films are used as metallic and insulating components, respectively. The interfaces of each NC layer are chemically engineered to create discontinuous insulating layers, i.e., spacers for improved sensitivity, and eventually to realize fully solution-processed pressure sensors. Device performance analysis with structural, chemical, and electronic characterization and conductive atomic force microscopy study reveals that hybrid nanostructure based pressure sensor shows an enhanced sensitivity of higher than 500 kPa -1 , reliability, and low power consumption with a wide range of pressure sensing. Nano-/micro-hierarchical structures are also designed by combining hybrid nanostructures with conventional microstructures, exhibiting further enhanced sensing range and achieving a record sensitivity of 2.72 × 10 4 kPa -1 . Finally, all-solution-processed pressure sensor arrays with high pixel density, capable of detecting delicate signals with high spatial selectivity much better than the human tactile threshold, are introduced.

  5. Radiation-resistant pressure transducers

    International Nuclear Information System (INIS)

    Abbasov, Sh.M.; Kerimova, T.I.

    2005-01-01

    Full text : The sensitive element of vibrofrequency tensor converter (VTC) is an electromechanical resonator of string type with electrostatic excitation of longitudinal mechanical vibrations. The string is made from tensosensitive thread-like monocrystal n-Ge1-x Six (length 1-5 mm, diameter 8-12 mcm) with current outlet and strictly fixed by ends at plate or deformable surface (in elastic element) at 50 mcm apartheid. With increasing Si atomic percent in n-Ge1-x Six the converter tens sensitivity increases. There has been shown the scheme of pressure transducer which contains monocrystalline silicon membrane and string tens converter from thread-like monocrystal Ge-Si. Using method, when crystal position on membrane while it deforms by pressure, corresponds to free (uptight) state, allowed to obtain the maximum sensitivity in measurement of pressure fluctuation. The transducers of absolute and pressure differential of this type can be used in automated systems of life activity. The high sensitivity of string transducers to pressure exceeding 100 hertz/mm (water column) permits to use them in devices for measuring gas concentration. The combination of optical and deformation methods of measurements forms the basis of their operation. The pressure change occurs due to the fact that gas molecules absorbing the quanta of incident light, become at excited state and then excitation energy of their vibrational-rotatory degrees of freedom converts to the energy of translational motion of molecules, i.e. to heat appropriate to pressure increase. Using these tens converters of high pressure one can prevent the possible accidents on oil pipe-like Baku-Tibilisi-Ceyhan

  6. A reliable measure of footwear upper comfort enabled by an innovative sock equipped with textile pressure sensors.

    Science.gov (United States)

    Herbaut, Alexis; Simoneau-Buessinger, Emilie; Barbier, Franck; Cannard, Francis; Guéguen, Nils

    2016-10-01

    Footwear comfort is essential and pressure distribution on the foot was shown as a relevant objective measurement to assess it. However, asperities on the foot sides, especially the metatarsals and the instep, make its evaluation difficult with available equipment. Thus, a sock equipped with textile pressure sensors was designed. Results from the mechanical tests showed a high linearity of the sensor response under incremental loadings and allowed to determine the regression equation to convert voltage values into pressure measurements. The sensor response was also highly repeatable and the creep under constant loading was low. Pressure measurements on human feet associated with a perception questionnaire exhibited that significant relationships existed between pressure and comfort perceived on the first, the third and the fifth metatarsals and top of the instep. Practitioner Summary: A sock equipped with textile sensors was validated for measuring the pressure on the foot top, medial and lateral sides to evaluate footwear comfort. This device may be relevant to help individuals with low sensitivity, such as children, elderly or neuropathic, to choose the shoes that fit the best.

  7. Efficacy and toxicity of self-polishing biocide-free antifouling paints

    International Nuclear Information System (INIS)

    Loeschau, Margit; Kraetke, Renate

    2005-01-01

    The ban on harmful substances in antifouling paints requires the development of new antifouling strategies. Alternatives should be as effective as conventional paints but of lower toxicity. In the present study two commercially available, self-polishing antifouling paints were examined in order to get information on their antifouling properties and toxicological potential. Efficacy was shown in settlement assays with the marine barnacle species Balanus amphitrite, however, efficacy was related to toxic effects observed on target and non-target organisms. Toxicity of the paint extracts was concentration-dependent and differed according to the paint and the species investigated. Toxicity could at least partially be attributed to zinc leached from the paints. Effects of a water-soluble paint were more pronounced in larvae of B. amphitrite, Artemia salina and in the green algae Dunaliella tertiolecta. Embryos of the freshwater species Danio rerio and Vibrio fisheri were more affected by a paint based on organic solvents. - For alternative antifouling paints efficacy as well as adverse effects on non-target organisms and the aquatic environment should be carefully assessed

  8. Connoisseurship Evaluation In Digital Painting Among Art Teachers In Malaysian Secondary School

    Directory of Open Access Journals (Sweden)

    Azimah A. Samah

    2016-07-01

    Full Text Available Connoisseurship evaluation is a form of evaluation and educational inquiry having qualitative characteristics. In this study, these skills are seen among Malaysian art teachers in secondary schools. Quality assessment depends on the evaluator who has the ability of some aspects. Among these are qualitative nuances experiences as well as ability to judge the goodness of the quality artwork. This study aims to look at the quality and evaluation skills of art teachers in Malaysia. The quality of the work will be seen on school students’ digital painting. The evaluation includes composition elements, color, interpretation and creativity of the digital painting. This study employed a quasi-experimental methodology with a single-group design to examine the digital painting among 53 students selected from schools in two districts of Selangor. The paintings were examined by two teachers in art and design education. The group’s production of painting was analyzed using Manova repeated measures to determine the skills of evaluating among the art teachers.There was a similarity in marks given among the teachers in four aspects of productive dimensions: composition, color manipulation, interpretation and creativity. This indicated that teachers were able to evaluate according to their expertise in art and design. This study offered a means to assist teachers with appropriate evaluation strategies in digital painting. In theory, this study will add to the understanding of cognitive systems and human information processing that relate to visual imagery system and skill of evaluation.

  9. Optimization and Prototyping of Medium Pressure Water (MPW) Depaint Process, Tri-Service Committee on Corrosion Proceedings

    National Research Council Canada - National Science Library

    Stropki, John

    1994-01-01

    This research program was designed to evaluate the potential of a paint stripping process that utilizes a medium pressure water jet as a viable alternative to the current practice of paint stripping...

  10. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  11. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  12. Effect of hydrophobic paints coating for tritium reduction in concrete materials

    International Nuclear Information System (INIS)

    Edao, Y.; Fukada, S.; Nishimura, Y.; Katayama, K.; Takeishi, T.; Hatano, Y.; Taguchi, A.

    2012-01-01

    Highlights: ► Effects of hydrophobic paint coating in tritium transport are investigated. ► Two kinds of paints, acrylic-silicon resin and epoxy resin are used. ► The hydrophobic paints are effective to reduce tritium permeation. ► The effect of tritium reduction of epoxy paint is higher than that of silicon. - Abstract: The effects of hydrophobic paint coating on a concrete material of cement paste on the tritium transport are investigated. The cement paste is coated with two kinds of paints, acrylic-silicon resin paint and epoxy resin paint. We investigated the amount of tritium trapped in the samples exposed to tritiated water vapor by means of sorption and release. It was found that both the hydrophobic paints could reduce effectively tritium permeation during 50 days exposure of tritiated water vapor. The effect of tritium reduction of the epoxy paint was higher than that of silicon while the amount of tritium trapped in the epoxy paint was larger than that of silicon due to difference of the structure. Based on an analysis of a diffusion model, the rate-determining step of tritium migration through cement paste coated with the paints is diffusion through the paints respectively. It was found that tritium was easy to penetrate through silicon because there were many pores or voids in the silicon comparatively. In the case of tritium released from the epoxy paint, it is considered that tritium diffusion in epoxy is slow due to retardation by isotope exchange reaction to water included in epoxy paint.

  13. Experimental investigation of drag reduction effect of Si-Polyurea paint

    International Nuclear Information System (INIS)

    Lee, In Won; Jang, Ho Yun; Chun, Ho Hwan; Kwon, Sang Hoon

    2008-01-01

    A novel Silicone-Polyurea paint has been newly developed and introduced for the antifouling marine paint. This paint is featured with such advantages as the shock-proofness and the scratch-proofness. In addition, the roughness of the resulting paint film is found to be much less than the conventional SPC AF paints. Ultra fast drying ability enables the formation of very thick paint film, e. g., 500μm. The Silicone-Polyurea resin exhibits similar material behavior as that of silicone rubber in terms of hardness and elongation. This material is regarded as a potent candidate to substantiate the compliant coating for the skin friction reduction. This study aims at the assessment of the drag reducing efficiency of the silicone-polyurea paint

  14. Automated measurement of pressure injury through image processing.

    Science.gov (United States)

    Li, Dan; Mathews, Carol

    2017-11-01

    To develop an image processing algorithm to automatically measure pressure injuries using electronic pressure injury images stored in nursing documentation. Photographing pressure injuries and storing the images in the electronic health record is standard practice in many hospitals. However, the manual measurement of pressure injury is time-consuming, challenging and subject to intra/inter-reader variability with complexities of the pressure injury and the clinical environment. A cross-sectional algorithm development study. A set of 32 pressure injury images were obtained from a western Pennsylvania hospital. First, we transformed the images from an RGB (i.e. red, green and blue) colour space to a YC b C r colour space to eliminate inferences from varying light conditions and skin colours. Second, a probability map, generated by a skin colour Gaussian model, guided the pressure injury segmentation process using the Support Vector Machine classifier. Third, after segmentation, the reference ruler - included in each of the images - enabled perspective transformation and determination of pressure injury size. Finally, two nurses independently measured those 32 pressure injury images, and intraclass correlation coefficient was calculated. An image processing algorithm was developed to automatically measure the size of pressure injuries. Both inter- and intra-rater analysis achieved good level reliability. Validation of the size measurement of the pressure injury (1) demonstrates that our image processing algorithm is a reliable approach to monitoring pressure injury progress through clinical pressure injury images and (2) offers new insight to pressure injury evaluation and documentation. Once our algorithm is further developed, clinicians can be provided with an objective, reliable and efficient computational tool for segmentation and measurement of pressure injuries. With this, clinicians will be able to more effectively monitor the healing process of pressure

  15. Quantification of pressure sensitive adhesive, residual ink, and other colored process contaminants using dye and color image analysis

    Science.gov (United States)

    Roy R. Rosenberger; Carl J. Houtman

    2000-01-01

    The USPS Image Analysis (IA) protocol recommends the use of hydrophobic dyes to develop contrast between pressure sensitive adhesive (PSA) particles and cellulosic fibers before using a dirt counter to detect all contaminants that have contrast with the handsheet background. Unless the sample contains no contaminants other than those of interest, two measurement steps...

  16. Development of Bio-Based Paint by using Methyl Esters from Palm Oil for Corrosion Inhibitor

    International Nuclear Information System (INIS)

    Mohibah Musa; Miradatul Najwa Muhd Rodhi; Najmiddin Yaakob; Ku Halim Ku Hamid; Juferi Idris

    2013-01-01

    Paint is used as a means of protection to prevent surfaces from being corroded over time. This research is focused on the development of a Bio-based paint made from palm oil methyl ester (POME) which originated from crude palm oil (CPO). New formulation paint has been developed to protect the pipeline from corrosion thus reducing the cost of the operation. Bio-based paint is made up of four components which are solvent, binder, additives, and pigment. The solvent in the bio-based paint is POME. The additives used are wetting and dispersing agent. The pigment used in the bio-based paint is TiO 2 . The formulation was developed by using a constant amount of additives and binder but varying the amount of POME at 10 ml, 15 ml, 20 ml, 25 ml and 30 ml with addition of water. The Standard Testing Methods for measuring the corrosion rate (ASTM G5-94(2011)) was carried out for each sample. In conclusion, it is proven that in the making of bio-based paint formulation for better corrosion inhibitor; the best amount of binder, additives and de-foam that should be used is 20 ml, 10 ml and 10 ml, respectively. (author)

  17. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  18. Development of paint area estimation software for ship compartments and structures

    Directory of Open Access Journals (Sweden)

    Doo-Yeoun Cho

    2016-03-01

    Full Text Available The painting process of large ships is an intense manual operation that typically comprises 9–12% of the total shipbuilding cost. Accordingly, shipbuilders need to estimate the required amount of anti-corrosive coatings and painting resources for inventory and cost control. This study aims to develop a software system which enables the shipbuilders to estimate paint area using existing 3D CAD ship structural models. The geometric information of the ships structure are extracted from the existing shipbuilding CAD/CAM system and used to create painting zones. After specifying the painting zones, users can generate the paint faces by clipping structural parts inside each zone. Finally, the paint resources may be obtained from the product of the paint areas and required paint thickness. Implementing the developed software system to real shipbuilders' operations has contributed to improved productivity, faster resource estimation, better accuracy, and fewer coating defects over their conventional manual calculation methods for painting resource estimation.

  19. Perceptual dimensions of style in paintings

    Directory of Open Access Journals (Sweden)

    Marković Slobodan

    2007-01-01

    Full Text Available The main purpose of this study is to specify the basic perceptual dimensions underlying the judgments of the physical features which define the style in paintings (e.g. salient form, colorful surface, oval contours etc.. The other aim of the study is to correlate these dimensions with the subjective (affective dimensions of the experience of paintings. In the preliminary study a set of 25 pairs of elementary perceptual descriptors were empirically specified, and a set of 25 bipolar scales were made (e.g. uncolored-multicolored. In the experiment 30 subjects judged 24 paintings (paintings were taken from the study of Radonjić and Marković, 2004 on 25 scales. Factor analysis revealed the four factors: form (scales: precise, neat, salient form etc., color (color contrast, lightness contrast, vivid colors, space (voluminosity, depth and oval contours and complexity (multicolored, ornate, detailed. Obtained factors reflected the nature of the phenomenological and neural segregation of form, color, depth processing, and partially of complexity processing (e.g. spatial frequency processing within both the form and color subsystem. The aim of the next step of analysis was to specify the correlations between two groups of judgments: (a mean judgments of 24 paintings on perceptual factors and (b mean judgments of the same set of 24 paintings on subjective (affective experience factors, i.e. regularity, attraction, arousal and relaxation (judgments taken from Radonjić and Marković, 2005. The following significant correlations were obtained: regularity-form, regularity-space, attraction-form and arousal-complexity (negative correlation. The reasons for the unexpected negative correlation between arousal and complexity should be specified in further studies.

  20. Apparatus Would Measure Temperatures Of Ball Bearings

    Science.gov (United States)

    Gibson, John C.; Fredricks, Thomas H.

    1995-01-01

    Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

  1. Comparison of Avian Responses to UV-Light-Reflective Paint on Wind Turbines: Subcontract Report, July 1999--December 2000

    Energy Technology Data Exchange (ETDEWEB)

    Young, D. P., Jr.; Erickson, W. P.; Strickland, M. D.; Good, R. E.; Sernka, K. J.

    2003-01-01

    To reduce the numbers of avian collisions with wind turbines, several measures have been employed with various levels of success. One hypothesis is that painting turbine blades to increase their visibility may reduce avian fatalities. This study examined the effects of painting wind turbine blades with UV-reflective paint on bird use and mortality at the Foote Creek Rim Wind Plant in Carbon County, Wyoming.

  2. Spatially digitized tactile pressure sensors with tunable sensitivity and sensing range.

    Science.gov (United States)

    Choi, Eunsuk; Sul, Onejae; Hwang, Soonhyung; Cho, Joonhyung; Chun, Hyunsuk; Kim, Hongjun; Lee, Seung-Beck

    2014-10-24

    When developing an electronic skin with touch sensation, an array of tactile pressure sensors with various ranges of pressure detection need to be integrated. This requires low noise, highly reliable sensors with tunable sensing characteristics. We demonstrate the operation of tactile pressure sensors that utilize the spatial distribution of contact electrodes to detect various ranges of tactile pressures. The device consists of a suspended elastomer diaphragm, with a carbon nanotube thin-film on the bottom, which makes contact with the electrodes on the substrate with applied pressure. The electrodes separated by set distances become connected in sequence with tactile pressure, enabling consecutive electrodes to produce a signal. Thus, the pressure is detected not by how much of a signal is produced but by which of the electrodes is registering an output. By modulating the diaphragm diameter, and suspension height, it was possible to tune the pressure sensitivity and sensing range. Also, adding a fingerprint ridge structure enabled the sensor to detect the periodicity of sub-millimeter grating patterns on a silicon wafer.

  3. Non-Photorealistic Rendering in Chinese Painting of Animals

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A set of algorithms is proposed in this paper to automatically transform 3D animal models to Chinese painting style. Inspired by real painting process in Chinese painting of animals, we divide the whole rendering process into two parts: borderline stroke making and interior shading. In borderline stroke making process we first find 3D model silhouettes in real-time depending on the viewing direction of a user. After retrieving silhouette information from all model edges, a stroke linking mechanism is applied to link these independent edges into a long stroke. Finally we grow a plain thin silhouette line to a stylus stroke with various widths at each control point and a 2D brush model is combined with it to simulate a Chinese painting stroke. In the interior shading pipeline, three stages are used to convert a Gouraud-shading image to a Chinese painting style image: color quantization, ink diffusion and box filtering. The color quantization stage assigns all pixels in an image into four color levels and each level represents a color layer in a Chinese painting. Ink diffusion stage is used to transfer inks and water between different levels and to grow areas in an irregular way. The box filtering stage blurs sharp borders between different levels to embellish the appearance of final interior shading image. In addition to automatic rendering, an interactive Chinese painting system which is equipped with friendly input devices can be also combined to generate more artistic Chinese painting images manually.

  4. Audience Perception of Effective Communication in Nigerian Paintings

    Directory of Open Access Journals (Sweden)

    Johnson Adelani Abodunrin

    2017-01-01

    Full Text Available Artists in Nigeria perceived effective communication differently irrespective of the socio-economic status.Communication effectiveness depends largely on the understanding of the message being passed between a sender and a receiver. Painting has been used over time to express emotion and feeling to the perceiving audience. The study is audience’s perception of communication in Nigeria painting and how it varies with the socio-economic characteristics such as age, education, gender, and being professional artist or art lovers. Questionnaires were distributed and administered to examine how the status of the art audience makes or mars effective communication in painting. The inferential statistics that were employed include “chi-square test” to test the relationship between different variables. The data were taken in ordinal form using Likert’s scale, and transformed into interval data. This was done by attaching statistical weights to the responses in the order of importance which were summed up for the parametric testing. Findings show that gender factor has nothing to do with the understanding of paintings. Also, the level of education obtained by the audience does not have much to do with understanding of contemporary Nigerian painting but a better exposure to the issue concerning the stylistic development of Nigerian painting. Art practitioners must adequately be guided on stylistic trend in painting, art education should be more intensified in educational curriculum in Nigeria. The paper concludes that audience requires a better exposure to the issues concerning the stylistic development of Nigerian painting for effective communication to take place.

  5. Microfabrication of a Novel Ceramic Pressure Sensor with High Sensitivity Based on Low-Temperature Co-Fired Ceramic (LTCC Technology

    Directory of Open Access Journals (Sweden)

    Chen Li

    2014-06-01

    Full Text Available In this paper, a novel capacitance pressure sensor based on Low-Temperature Co-Fired Ceramic (LTCC technology is proposed for pressure measurement. This approach differs from the traditional fabrication process for a LTCC pressure sensor because a 4J33 iron-nickel-cobalt alloy is applied to avoid the collapse of the cavity and to improve the performance of the sensor. Unlike the traditional LTCC sensor, the sensitive membrane of the proposed sensor is very flat, and the deformation of the sensitivity membrane is smaller. The proposed sensor also demonstrates a greater responsivity, which reaches as high as 13 kHz/kPa in range of 0–100 kPa. During experiments, the newly fabricated sensor, which is only about 6.5 cm2, demonstrated very good performance: the repeatability error, hysteresis error, and nonlinearity of the sensor are about 4.25%, 2.13%, and 1.77%, respectively.

  6. Smart monitoring of fluid intake and bladder voiding using pressure sensitive mats.

    Science.gov (United States)

    Cohen-McFarlane, Madison; Green, James R; Knoefel, Frank; Goubran, Rafik

    2016-08-01

    Pressure sensitive mats have been used in noninvasive smart monitoring for a variety of problems including breathing rate monitoring, sleep monitoring, mobility, and weight. This paper describes a proof of concept application of pressure mats to monitor fluid intake/output (fluid cycle) events during the night. The ability to more accurately track such events has potential implications for monitoring those individuals who have nocturia, a condition where a person wakes at night to urinate. Data were collected from a healthy young female subject instructed to drink as much water as was comfortable (700mL) and lie in a supine position on a mattress located directly on three pressure mats. This was compared to an initial data set collected immediately after voiding but before drinking, 30 minutes after drinking, 60 minutes after drinking and a final data set after again voiding the bladder. The additional pressure from the 700mL of water was detectible and tracked over the course of the hour-long testing session under idealized conditions. This provides a proof-of-concept that nocturnal fluid intake and bladder voiding events can be tracked using non-invasive pressure-sensitive mats, however additional testing and development is required to achieve a deployable monitoring system.

  7. Pressure measurements in harsh environments

    International Nuclear Information System (INIS)

    Cook, C.W.; Ames, E.S.

    1979-01-01

    A fluid coupled plate (FCP) gage was designed which allows pressure measurements to be made in harsh environments (including debris) using conventional pressure transducers. The pressure transducer is isolated by means of a rigid force plate which is supported by a bellows having one corrugation. This portion of the gage is machined from a single piece of material. The interior of the gage is filled with a phenol fluid which has a low compressibility

  8. Historical evolution of oil painting media: A rheological study

    Science.gov (United States)

    de Viguerie, Laurence; Ducouret, Guylaine; Lequeux, François; Moutard-Martin, Thierry; Walter, Philippe

    2009-09-01

    Rheology is the science of flow, which is a phenomenon found in every painting operation, such as decorative paintings or protective coatings. In this article, the principles of rheology as applied to paintings and coatings are recalled in a first part and the rheological criteria required in the paint industry presented. Indeed, different flow behaviours leads to different finishes. The same procedure and techniques as in industry can be employed to explain some evolutions in oil painting aspects over the centuries. The first recipes for oil painting indicate the use of treated oil, resins and spirits. This article deals with the evolution of the composition of these systems as media for oil painting, according to rheological clues. During the Renaissance period, the media used were Newtonian or slightly shear thinning and allowed one a perfect levelling. Then techniques changed, paints became more opaque with less addition of oil/resin media, and brushstrokes appeared visible. Some preparations containing lead, oil and mastic resin, whose flow behaviour is closed to those required in industry, may have appeared during the 17th century and are still used and sold today. To cite this article: L. de Viguerie et al., C. R. Physique 10 (2009).

  9. The out-of-pile test for internal pressure measurement of nuclear fuel rod using LVDT

    Energy Technology Data Exchange (ETDEWEB)

    Son, J. M.; Kim, B. K.; Kim, D. S.; Joo, K. N.; Park, S. J.; Kang, Y. H.; Kim, Y. K.; Yeum, K. I. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    As a part of the development of instrumentation technologies for the nuclear fuel irradiation test in HANARO(High-flux Advanced Nuclear Application Reactor), the internal pressure measurement technique of the nuclear fuel rod is being developed using LVDT(Linear Variable Differential Transformer). The objectives of this test were to understand the LVDT's characteristics and to study its application techniques for fuel irradiation technology. It will be required to analyze the acquired internal pressure of fuel rod during fuel irradiation test in HANARO. Therefore, the out of pile test system for pressure measurement was developed, and the test with the LVDT at room temperature were performed. This test were implemented in 1 kg/cm{sup 2} increment from 1 kg/cm{sup 2} to 30 kg/cm{sup 2}, and repeated 6 times at same condition. The LVDT's sensitivities were obtained by following two ways, the one by test and the other by calculation from characteristics data. These two sensitivities were compared and analyzed. The calculation method for internal pressure of nuclear fuel rod at specified temperature was also established. The results of the out-of-pile test will be used to predict accurately the internal pressure of fuel rod during irradiation test. And, the well qualified out-of-pile tests are needed to understand the LVDT's detail characteristics at high temperature for the detail design of the fuel irradiation capsule.

  10. The out-of-pile test for internal pressure measurement of nuclear fuel rod using LVDT

    Energy Technology Data Exchange (ETDEWEB)

    Min, Sohn Jae; Kang, Y. H.; Kim, B. G. [and others

    2001-11-01

    As a part of the development of instrumentation technologies for the nuclear fuel irradiation test in HANARO, the internal pressure measurement technique of the nuclear fuel rod is being developed using LVDT. The objectives of this test were to understand the LVDT's characteristics and to study its application techniques for fuel irradiation technology. It will be required to analyze the acquired internal pressure of fuel rod during fuel irradiation test in HANARO. The out-of-pile test system for pressure measurement was developed, and the test with the LVDT at room temperature(19 .deg. C) were performed. A out-of-pile test were implemented in 1 kg/cm{sup 2} increment from 1 kg/cm{sup 2} to 30 kg/cm{sup 2} and repeated 6 times at each condition. The LVDT's sensitivities were obtained by following two ways, the one by test and the other by calculation from characteristics data. These two sensitivities were compared and analyzed. The calculation method for internal pressure of nuclear fuel rod at specified temperature was also established. This report describes the system configuration, the out-of-pile test procedures, and the results. The results of the out-of-pile test will be used to predict accurately the internal pressure of fuel rod during irradiation test. And, the well qualified out-of-pile tests are needed to understand the LVDT's detail characteristics for the detail design of the fuel irradiation capsule.

  11. Rheological Properties of Extreme Pressure Greases Measured Using a Process Control Rheometer

    DEFF Research Database (Denmark)

    Glasscock, Julie; Smith, Robin S.

    2012-01-01

    A new process control rheometer (PCR) designed for use in industrial process flows has been used to measure the rheological properties of three extreme-pressure greases. The rheometer is a robust yet sensitive instrument designed to operate in an industrial processing environment in either in......-line or on-line configurations. The PCR was able to measure the rheological properties including the elastic modulus, viscous modulus, and complex viscosity of the greases which in an industrial flow application could be used as variables in a feedback system to control the process and the quality...

  12. Direct Growth of Graphene Films on 3D Grating Structural Quartz Substrates for High-Performance Pressure-Sensitive Sensors.

    Science.gov (United States)

    Song, Xuefen; Sun, Tai; Yang, Jun; Yu, Leyong; Wei, Dacheng; Fang, Liang; Lu, Bin; Du, Chunlei; Wei, Dapeng

    2016-07-06

    Conformal graphene films have directly been synthesized on the surface of grating microstructured quartz substrates by a simple chemical vapor deposition process. The wonderful conformality and relatively high quality of the as-prepared graphene on the three-dimensional substrate have been verified by scanning electron microscopy and Raman spectra. This conformal graphene film possesses excellent electrical and optical properties with a sheet resistance of 80% (at 550 nm), which can be attached with a flat graphene film on a poly(dimethylsiloxane) substrate, and then could work as a pressure-sensitive sensor. This device possesses a high-pressure sensitivity of -6.524 kPa(-1) in a low-pressure range of 0-200 Pa. Meanwhile, this pressure-sensitive sensor exhibits super-reliability (≥5000 cycles) and an ultrafast response time (≤4 ms). Owing to these features, this pressure-sensitive sensor based on 3D conformal graphene is adequately introduced to test wind pressure, expressing higher accuracy and a lower background noise level than a market anemometer.

  13. A Case Study Application Of Time Study Model In Paint ...

    African Journals Online (AJOL)

    This paper presents a case study in the development and application of a time study model in a paint manufacturing company. The organization specializes in the production of different grades of paint and paint containers. The paint production activities include; weighing of raw materials, drying of raw materials, dissolving ...

  14. Environment sensitive cracking in pressure boundary materials of light water reactors

    International Nuclear Information System (INIS)

    Hanninen, H.; Aho-Mantila, I.; Torronen, K.

    1987-08-01

    A review of the various forms of environment sensitive cracking in pressure boundary materials of light water reactors is presented. The available methods and the most promising future possibilities of preventive maintenance to counteract the environmental degradation are evaluated. Environment sensitive cracking is considered from the metallurgical, mechanical and environmental point of view. The main emphasis is on intergranular stress corrosion cracking of austenitic stainless steels and high strength Ni-base alloys as well as on corrosion fatigue of low alloy and stainless steels. Additionally, some general ideas on how to predict, reduce, monitor or eliminate environment sensitive cracking in service are presented

  15. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  16. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  17. The high temperature out-of-pile test of LVDT for internal pressure measurement of nuclear fuel rod

    Energy Technology Data Exchange (ETDEWEB)

    Son, J. M.; Kim, B. K.; Kim, D. S.; Yoon, K. B.; Sin, Y. T.; Park, S. J.; Kang, Y. H. [KAERI, Taejon (Korea, Republic of)

    2002-10-01

    As a part of the development of instrumentation technologies for the nuclear fuel irradiation test in HANARO(High-flux Advanced Nuclear Application Reactor), the internal pressure measurement technique of the nuclear fuel rod is being developed using LVDT(Linear Variable Differential Transformer). As the results of out-of-pile test at room temperature, it was concluded that the well qualified out-of-pile tests were needed to understand the LVDT's detail characteristics at high temperature for the detail design of the fuel irradiation capsule, because LVDT is very sensitive to variation of temperature. Therefore, the high temperature out-of-pile test system for pressure measurement was developed, and this test was performed under the temperature condition between room temperature and 300 .deg. C increasing the pressure from 0 bar to 30 bar. The LVDT's high temperature characteristics and temperature sensitivity of LVDT were analyzed through this experiment. Based on the result of this test, the method for the application of LVDT at high temperature was introduced. It is known that the results will be used to predict accurately the internal pressure of fuel rod during irradiation test.

  18. The abstract unconscious in painting

    OpenAIRE

    Parker, David

    2009-01-01

    The Abstract Unconscious in Painting addresses painting as experiential process, critically examining the psychological factors involved in the formation of imagery as it emerges through imaginative responses to the process of mark making and the structuring of space and form. The paper sets this process in relation to theoretical material drawn from Jungian and Post Jungian Psychology ( Avens, 1980; Hillman, 1975) the arts ( Gombrich, 1960; Kuspit, 2000; McKeever, 2005; Worringer, 1908) and ...

  19. Limitation of leakage rate measurement sensitivity; Limitation de la sensibilite des mesures de debit de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Paigne, Jacques [Commissariat a l' energie atomique et aux energies alternatives - CEA, Services de Physique Appliquee (France)

    1964-08-15

    This note reports an experimental study which aimed at determining to which extent an enclosure degassing could affect the sensitivity of a helium detection cell because of an increased background noise. The author first describes the measurement method and the helium partial pressure measurement method. He then reports an application to leakage rate measurements, and discusses the influence of background noise (influence of degassing, and influence of atmospheric air)

  20. Pigeons can discriminate "good" and "bad" paintings by children.

    Science.gov (United States)

    Watanabe, Shigeru

    2010-01-01

    Humans have the unique ability to create art, but non-human animals may be able to discriminate "good" art from "bad" art. In this study, I investigated whether pigeons could be trained to discriminate between paintings that had been judged by humans as either "bad" or "good". To do this, adult human observers first classified several children's paintings as either "good" (beautiful) or "bad" (ugly). Using operant conditioning procedures, pigeons were then reinforced for pecking at "good" paintings. After the pigeons learned the discrimination task, they were presented with novel pictures of both "good" and "bad" children's paintings to test whether they had successfully learned to discriminate between these two stimulus categories. The results showed that pigeons could discriminate novel "good" and "bad" paintings. Then, to determine which cues the subjects used for the discrimination, I conducted tests of the stimuli when the paintings were of reduced size or grayscale. In addition, I tested their ability to discriminate when the painting stimuli were mosaic and partial occluded. The pigeons maintained discrimination performance when the paintings were reduced in size. However, discrimination performance decreased when stimuli were presented as grayscale images or when a mosaic effect was applied to the original stimuli in order to disrupt spatial frequency. Thus, the pigeons used both color and pattern cues for their discrimination. The partial occlusion did not disrupt the discriminative behavior suggesting that the pigeons did not attend to particular parts, namely upper, lower, left or right half, of the paintings. These results suggest that the pigeons are capable of learning the concept of a stimulus class that humans name "good" pictures. The second experiment showed that pigeons learned to discriminate watercolor paintings from pastel paintings. The subjects showed generalization to novel paintings. Then, as the first experiment, size reduction test

  1. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    DEFF Research Database (Denmark)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka

    2017-01-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identi......Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could...... be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for Me......V Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples...

  2. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  3. Tapestry paintings in the main church in Breda

    Directory of Open Access Journals (Sweden)

    Micha Leeflang

    2010-02-01

    Full Text Available This article is an adaptation of some reports made between 2005 and 2007 for the art-historical preliminary research into the restorations of the wall paintings in the main church in Breda. In addition, a proposal for restoration is given for the paintings dealt with, emphasizing the preservation of the representations. The first priority in all the paintings is consolidating loose paint and removing dirt from the surface. Subsequently, old putty is removed so as to expose the original painting as much as possible. During the restoration large voids will have to be filled up in a neutral shade – in a lighter shade than the original – so that the distinction between original and restoration remains visible. On the south choir wall in the second bay of the ambulatory at the top three pairs of yellow cloth scissors are painted on a green field (illustration 1. As scissors were an important element in the textile industry, it is plausible that this chapel was painted on the instructions of the cloth guild (illustration 2. The various stages in the production process of the cloth were strictly inspected. These inspections were accompanied by affixing lead seals (illustration 3, which could be considered a full guarantee for the client. Around the scissors in the cloth- scissors chapel in Breda small circles are painted, which were not mentioned in the literature. Although the exact meaning is unknown, these circles could represent lead seals and could thus be a reference to the high quality of the products of the cloth guild in Breda. Both on the second choir pillar at the southside and on the freestanding clustered pillar in the south ambulatory angels with a red cloth of honour are painted (illustration 7, 9 and 10. The former painting dates from approximately 1510-1520 and the latter from the second half of the sixteenth century. It is very likely that the red painted cloth of honour functioned as a background for a sculpture. In miniature art

  4. Study of a pressure measurement method using laser ionization for extremely-high vacuum

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    A method of measuring pressures in the range of extremely-high vacuum (XHV) using the laser ionization has been studied. For this purpose, nonresonant multiphoton ionization of various kinds of gases has been studied, and highly-sensitive ion-detection systems and an extremely-high vacuum equipment were fabricated. These results are presented in detail. Two ion-detection systems were fabricated and tested: the one is based on the pulse-counting method, and the other utilizes the image-processing technique. The former is superior in detecting a few ions or less. The latter was processing technique. The former is superior in detecting a few ions or less. The latter was verified to able to count accurately the number of ions in the range of a few to several hundreds. To obtain the information on residual gases and test our pressure measurement system, an extremely-high vacuum system was fabricated in our own fashion, attained a pressure lower than 1 x 10 -10 Pa, measured with an extractor gauge. The outgassing rate of this vacuum vessel was measured to be 7.8 x 10 -11 Pa·m 3 /s·m 2 . The surface structures and the surface compositions of the raw material, the machined material, and the machined-and-outgased material were studied by SEM and AES. Besides, the pumping characteristics and the residual gases of the XHV system were investigated in detail at each pumping stage. On the course of these studies, the method of pressure measurement using the laser-ionization has been verified to be very effective for measuring pressures in XHV. (J.P.N.)

  5. Pressure-sensitive strain sensor based on a single percolated Ag nanowire layer embedded in colorless polyimide

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chan-Jae [Display Materials & Components Research Center, Korea Electronics Technology Institute, 68 Yatap-dong, Bundang-gu, Seongnam 463-816 (Korea, Republic of); Jun, Sungwoo [Display Materials & Components Research Center, Korea Electronics Technology Institute, 68 Yatap-dong, Bundang-gu, Seongnam 463-816 (Korea, Republic of); Display and Nanosystem Laboratory, College of Engineering, Korea University, Seoul 136-713 (Korea, Republic of); Ju, Byeong-Kwon [Display and Nanosystem Laboratory, College of Engineering, Korea University, Seoul 136-713 (Korea, Republic of); Kim, Jong-Woong, E-mail: wyjd@keti.re.kr [Display Materials & Components Research Center, Korea Electronics Technology Institute, 68 Yatap-dong, Bundang-gu, Seongnam 463-816 (Korea, Republic of)

    2017-06-01

    This paper presents the fabrication of an elastomer-free, transparent, pressure-sensitive strain sensor consisting of a specially designed silver nanowire (AgNW) pattern and colorless polyimide (cPI). A percolated AgNW network was patterned with a simple tandem compound circuit, which was then embedded in the surface of the cPI via inverted layer processing. The resulting film-type sensor was highly transparent (~93.5% transmittance at 550 nm) and mechanically stable (capable of resisting 10000 cycles of bending to a 500 µm radius of curvature). We demonstrated that a thin, transparent, and mechanically stable electrode can be produced using a combination of AgNWs and cPI, and used to produce a system sensitive to pressure-induced bending. The capacitance of the AgNW tandem compound electrode pattern grew via fringing, which increased with the pressure-induced bending applied to the surface of the sensor. The sensitivity was four times higher than that of an elastomeric pressure sensor made with the same design. Finally, we demonstrated a skin-like pressure sensor attached to the inside wrist of a human arm. - Highlights: • A thin, transparent pressure sensor was fabricated from AgNWs and cPI. • An AgNW network was patterned with a simple circuit, and then embedded into cPI. • The resulting film-type sensor was highly transparent and mechanically stable. • The sensor sensitivity was 4x higher than that of an elastomeric pressure sensor.

  6. Nd:YVO4 laser removal of graffiti from granite. Influence of paint and rock properties on cleaning efficacy

    International Nuclear Information System (INIS)

    Rivas, T.; Pozo, S.; Fiorucci, M.P.; López, A.J.; Ramil, A.

    2012-01-01

    Highlights: ► Cleaning using NdYVO 4 laser at 355 nm of four different graffiti colours applied on granites. ► Analysis of the influence of paint composition and properties of rocks on the process. ► Composition of the paints and, in turn reflectance, determine the removal effectiveness. ► The laser removal is not conditioned by properties of the stones. - Abstract: This paper presents the cleaning efficiency results for four differently coloured graffiti paints applied to two types of granitic stone by Nd:YVO 4 laser at 355 nm. The paints were characterized in terms of mineralogy and chemistry using x-ray fluorescence, X-ray diffraction, Fourier transform infrared (FTIR) spectroscopy and scanning electron microscope (SEM); paint absorbance in the ultraviolet–visible-infrared range (200–2000 nm) was also assessed. The studied granites had different mineralogy, texture and porosity properties. Cleaning efficiency was evaluated by polarized microscopy, SEM, FTIR spectroscopy and spectrophotometer colour measurements. The results indicate differences in the effectiveness of surface cleaning for the blue, red and black paints as opposed to the silver paint, mainly attributed to chemical composition. No evidence was found that the granite properties had a bearing on laser effectiveness, although the degree, type and spatial distribution of transgranular fissures in the stone affected the overall assessment of cleaning effectiveness. Polarized light microscopy observations and colour measurements showed that the intensity and distribution of fissures affect the depth of paint penetration, ultimately affecting the cleaning efficiency for both granites.

  7. The identification of synthetic organic pigments in modern paints and modern paintings using pyrolysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Russell, Joanna; Singer, Brian W; Perry, Justin J; Bacon, Anne

    2011-05-01

    A collection of more than 70 synthetic organic pigments were analysed using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We report on the analysis of diketo-pyrrolo-pyrrole, isoindolinone and perylene pigments which are classes not previously reported as being analysed by this technique. We also report on a number of azo pigments (2-naphthol, naphthol AS, arylide, diarylide, benzimidazolone and disazo condensation pigments) and phthalocyanine pigments, the Py-GC-MS analysis of which has not been previously reported. The members of each class were found to fragment in a consistent way and the pyrolysis products are reported. The technique was successfully applied to the analysis of paints used by the artist Francis Bacon (1909-1992), to simultaneously identify synthetic organic pigments and synthetic binding media in two samples of paint taken from Bacon's studio and micro-samples taken from three of his paintings and one painting attributed to him.

  8. Introductory guide to painting

    CSIR Research Space (South Africa)

    Cromarty, R.E

    1985-01-01

    Full Text Available , and have doubts about it, you are wel- come to contact the NBRl for advice. It is always best when buying a paint system to select the products of a single manufacturer. the grain as it dries. Several coats can be used to give a high-gloss finish... rendering Those who have lived on a farm will probably remember how surplus fat used to be treated with an alkali to make soap. The same thing can happen at the point where some oil paints come in contact with the wall. The alkali, which is always...

  9. The Capability of Fiber Bragg Grating Sensors to Measure Amputees’ Trans-Tibial Stump/Socket Interface Pressures

    Directory of Open Access Journals (Sweden)

    Faisal Rafiq Mahamd Adikan

    2013-08-01

    Full Text Available This study presents the first investigation into the capability of fiber Bragg grating (FBG sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee’s Patellar Tendon (PT bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.

  10. Paintings discrimination by mice: Different strategies for different paintings.

    Science.gov (United States)

    Watanabe, Shigeru

    2017-09-01

    C57BL/6 mice were trained on simultaneous discrimination of paintings with multiple exemplars, using an operant chamber with a touch screen. The number of exemplars was successively increased up to six. Those mice trained in Kandinsky/Mondrian discrimination showed improved learning and generalization, whereas those trained in Picasso/Renoir discrimination showed no improvements in learning or generalization. These results suggest category-like discrimination in the Kandinsky/Mondrian task, but item-to-item discrimination in the Picasso/Renoir task. Mice maintained their discriminative behavior in a pixelization test with various paintings; however, mice in the Picasso/Renoir task showed poor performance in a test that employed scrambling processing. These results do not indicate that discrimination strategy for any Kandinsky/Mondrian combinations differed from that for any Picasso/Monet combinations but suggest the mice employed different strategies of discrimination tasks depending upon stimuli. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Using anti-corrosive paints on ships

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J

    1969-02-07

    Anit-corrosive paints on the outside of ship's hulls fall into 3 groups: the area below the water, the boot- topping area at the waterline, and the weatherwork including the hull and superstructure. Typical formulations of primer and paint are given for use in each section. Anti-corrosion paints must always be considered in conjunction with the kind and amount of surface preparation that can be given. The requirement for faster descaling techniques and higher standards of surface preparation has led to the introduction of automated centrifugal abrasive blasting machines for all new plates and sections. If it is not possible to remove old coatings by abrasive blasting, then the traditional method of chipping followed by wire brushing must be used. The removal of mill scale by abrasive blasting can produce a clean metal surface which is liable to rapid corrosion unless it is painted immediately. A pre-fabrication or shop primer is used which is normally applied by airless spray equipment synchronized with the sand blasting machinery.

  12. Modern gas-based temperature and pressure measurements

    CERN Document Server

    Pavese, Franco

    2013-01-01

    This 2nd edition volume of Modern Gas-Based Temperature and Pressure Measurements follows the first publication in 1992. It collects a much larger set of information, reference data, and bibliography in temperature and pressure metrology of gaseous substances, including the physical-chemical issues related to gaseous substances. The book provides solutions to practical applications where gases are used in different thermodynamic conditions. Modern Gas-Based Temperature and Pressure Measurements, 2nd edition is the only comprehensive survey of methods for pressure measurement in gaseous media used in the medium-to-low pressure range closely connected with thermometry. It assembles current information on thermometry and manometry that involve the use of gaseous substances which are likely to be valid methods for the future. As such, it is an important resource for the researcher. This edition is updated through the very latest scientific and technical developments of gas-based temperature and pressure measurem...

  13. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  14. Experimental study on the influence of chemical sensitizer on pressure resistance in deep water of emulsion explosives

    Science.gov (United States)

    Liu, Lei; zhang, Zhihua; Wang, Ya; Qin, hao

    2018-03-01

    The study on the pressure resistance performance of emulsion explosives in deep water can provide theoretical basis for underwater blasting, deep-hole blasting and emulsion explosives development. The sensitizer is an important component of emulsion explosives. By using reusable experimental devices to simulate the charge environment in deep water, the influence of the content of chemical sensitizer on the deep-water pressure resistance performance of emulsion explosives was studied. The experimental results show that with the increasing of the content of chemical sensitizer, the deep-water pressure resistance performance of emulsion explosives gradually improves, and when the pressure is fairly large, the effect is particularly pronounced; in a certain range, with the increase of the content of chemical sensitizer, that emulsion explosives’ explosion performance also gradually improve, but when the content reaches a certain value, the explosion properties declined instead; under the same emulsion matrix condition, when the content of NANO2 is 0.2%, that the emulsion explosives has good resistance to water pressure and good explosion properties. The correctness of the results above was testified in model blasting.

  15. Training facilitates object recognition in cubist paintings

    Directory of Open Access Journals (Sweden)

    Martin Wiesmann

    2010-03-01

    Full Text Available To the naïve observer, cubist paintings contain geometrical forms in which familiar objects are hardly recognizable, even in the presence of a meaningful title. We used fMRI to test whether a short training session about Cubism would facilitate object recognition in paintings by Picasso, Braque and Gris. Subjects, who had no formal art education, were presented with titled or untitled cubist paintings and scrambled images, and performed object recognition tasks. Relative to the control group, trained subjects recognized more objects in the paintings, their response latencies were significantly shorter, and they showed enhanced activation in the parahippocampal cortex, with a parametric increase in the amplitude of the fMRI signal as a function of the number of recognized objects. Moreover, trained subjects were slower to report not recognizing any familiar objects in the paintings and these longer response latencies were correlated with activation in a fronto-parietal network. These findings suggest that trained subjects adopted a visual search strategy and used contextual associations to perform the tasks. Our study supports the proactive brain framework, according to which the brain uses associations to generate predictions.

  16. The art in science: electron microscopy and paintings conservation

    International Nuclear Information System (INIS)

    Waters, L.

    2003-01-01

    Full text: When examining a painting, a conservator uses many different and complementary methods of analysis to build an understanding of the materials and way the painting was constructed. Common methods of examination include x-radiography, infrared reflectography, ultraviolet fluorescence and optical microscopy of the surface of the painting. Minute samples of paint prepared as cross-sections are sometimes taken for optical examination under the microscope, and it is these that can, conveniently, be further analysed with electron microscopy to yield another level of information. Electron microscopy has a valuable role to play within the examination of paintings, be it for pigment identification alone, or at the other end of the spectrum, for informing issues around the attribution of works of art. This paper provides an overview of the use of electron microscopy in the conservation of paintings by discussing examples of work undertaken by the National Gallery of Victoria and the CSIRO. Work described includes the problem of distinguishing between restorers' original paint in a landscape by Arthur Streeton, and the examination of the ground or priming layer in a Rembrandt portrait which clarified its attribution to his studio. Copyright (2003) Australian Microbeam Analysis Society

  17. Comparison of the sensitivity of mass spectrometry atmospheric pressure ionization techniques in the analysis of porphyrinoids.

    Science.gov (United States)

    Swider, Paweł; Lewtak, Jan P; Gryko, Daniel T; Danikiewicz, Witold

    2013-10-01

    The porphyrinoids chemistry is greatly dependent on the data obtained in mass spectrometry. For this reason, it is essential to determine the range of applicability of mass spectrometry ionization methods. In this study, the sensitivity of three different atmospheric pressure ionization techniques, electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization, was tested for several porphyrinods and their metallocomplexes. Electrospray ionization method was shown to be the best ionization technique because of its high sensitivity for derivatives of cyanocobalamin, free-base corroles and porphyrins. In the case of metallocorroles and metalloporphyrins, atmospheric pressure photoionization with dopant proved to be the most sensitive ionization method. It was also shown that for relatively acidic compounds, particularly for corroles, the negative ion mode provides better sensitivity than the positive ion mode. The results supply a lot of relevant information on the methodology of porphyrinoids analysis carried out by mass spectrometry. The information can be useful in designing future MS or liquid chromatography-MS experiments. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Temperature Compensation Fiber Bragg Grating Pressure Sensor Based on Plane Diaphragm

    Science.gov (United States)

    Liang, Minfu; Fang, Xinqiu; Ning, Yaosheng

    2018-03-01

    Pressure sensors are the essential equipments in the field of pressure measurement. In this work, we propose a temperature compensation fiber Bragg grating (FBG) pressure sensor based on the plane diaphragm. The plane diaphragm and pressure sensitivity FBG (PS FBG) are used as the pressure sensitive components, and the temperature compensation FBG (TC FBG) is used to improve the temperature cross-sensitivity. Mechanical deformation model and deformation characteristics simulation analysis of the diaphragm are presented. The measurement principle and theoretical analysis of the mathematical relationship between the FBG central wavelength shift and pressure of the sensor are introduced. The sensitivity and measure range can be adjusted by utilizing the different materials and sizes of the diaphragm to accommodate different measure environments. The performance experiments are carried out, and the results indicate that the pressure sensitivity of the sensor is 35.7 pm/MPa in a range from 0 MPa to 50 MPa and has good linearity with a linear fitting correlation coefficient of 99.95%. In addition, the sensor has the advantages of low frequency chirp and high stability, which can be used to measure pressure in mining engineering, civil engineering, or other complex environment.

  19. Temperature Compensation Fiber Bragg Grating Pressure Sensor Based on Plane Diaphragm

    Science.gov (United States)

    Liang, Minfu; Fang, Xinqiu; Ning, Yaosheng

    2018-06-01

    Pressure sensors are the essential equipments in the field of pressure measurement. In this work, we propose a temperature compensation fiber Bragg grating (FBG) pressure sensor based on the plane diaphragm. The plane diaphragm and pressure sensitivity FBG (PS FBG) are used as the pressure sensitive components, and the temperature compensation FBG (TC FBG) is used to improve the temperature cross-sensitivity. Mechanical deformation model and deformation characteristics simulation analysis of the diaphragm are presented. The measurement principle and theoretical analysis of the mathematical relationship between the FBG central wavelength shift and pressure of the sensor are introduced. The sensitivity and measure range can be adjusted by utilizing the different materials and sizes of the diaphragm to accommodate different measure environments. The performance experiments are carried out, and the results indicate that the pressure sensitivity of the sensor is 35.7 pm/MPa in a range from 0 MPa to 50 MPa and has good linearity with a linear fitting correlation coefficient of 99.95%. In addition, the sensor has the advantages of low frequency chirp and high stability, which can be used to measure pressure in mining engineering, civil engineering, or other complex environment.

  20. A Measure of Spiritual Sensitivity for Children

    Science.gov (United States)

    Stoyles, Gerard John; Stanford, Bonnie; Caputi, Peter; Keating, Alysha-Leigh; Hyde, Brendan

    2012-01-01

    Spirituality is an essential influence in a child's development. However, an age-appropriate measure of child's spiritual sensitivity is not currently available in the literature. This paper describes the development of a measure of children's spiritual sensitivity, the Spiritual Sensitivity Scale for Children (SSSC). Statistical analyses…

  1. Determination of diuron and the antifouling paint biocide Irgarol 1051 in Dutch marinas and coastal waters

    NARCIS (Netherlands)

    Lamoree, M.H.; Swart, C.P.; van der Horst, A.; van Hattum, A.G.M.

    2002-01-01

    A sensitive LC-electrospray MS-MS method using off-line solid-phase extraction for the determination of diuron and Irgarol 1051 has been developed, enabling determination of both compounds at sub-ppt levels. Diuron and Irgarol 1051 are used as alternatives for tributyltin in antifouling paints that

  2. THE ART OF POETRY AND PAINTING: NEW SUBJETIVITIES IN POST-INDEPENDENCE ANGOLA

    OpenAIRE

    Carmen Lúcia Tindó Secco

    2008-01-01

    The art of poetry and painting: new poetic and pictorial subjectivities in Angola after its Independence. The post 80's decades and the rising of other forms of revolution in the aesthetic language. Themes and creative literary procedures: the existential reason, the individual sensitivities, the literary imagination. The presence of love, the myths, of History, of the dreams in the Angolan arts of the last decades as strategies of cultural resistance.

  3. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring.

    Science.gov (United States)

    Schwartz, Gregor; Tee, Benjamin C-K; Mei, Jianguo; Appleton, Anthony L; Kim, Do Hwan; Wang, Huiliang; Bao, Zhenan

    2013-01-01

    Flexible pressure sensors are essential parts of an electronic skin to allow future biomedical prostheses and robots to naturally interact with humans and the environment. Mobile biomonitoring in long-term medical diagnostics is another attractive application for these sensors. Here we report the fabrication of flexible pressure-sensitive organic thin film transistors with a maximum sensitivity of 8.4 kPa(-1), a fast response time of 15,000 cycles and a low power consumption of monitoring, which may lead to the use of flexible pressure sensors in mobile health monitoring and remote diagnostics in cardiovascular medicine.

  4. Laser Induced Fluorescence Measurements in a Hall Thruster Plume as a Function of Background Pressure

    Science.gov (United States)

    Spektor, R.; Tighe, W. G.; Kamhawi, H.

    2016-01-01

    A set of Laser Induced Fluorescence (LIF) measurements in the near-field region of the NASA- 173M Hall thruster plume is presented at four background pressure conditions varying from 9.4 x 10(exp -6) torr to 3.3 x 10(exp -5) torr. The xenon ion velocity distribution function was measured simultaneously along the axial and radial directions. An ultimate exhaust velocity of 19.6+/-0.25 km/s achieved at a distance of 20 mm was measured, and that value was not sensitive to pressure. On the other hand, the ion axial velocity at the thruster exit was strongly influenced by pressure, indicating that the accelerating electric field moved inward with increased pressure. The shift in electric field corresponded to an increase in measured thrust. Pressure had a minor effect on the radial component of ion velocity, mainly affecting ions exiting close to the channel inner wall. At that radial location the radial component of ion velocity was approximately 1000 m/s greater at the lowest pressure than at the highest pressure. A reduction of the inner magnet coil current by 0.6 A resulted in a lower axial ion velocity at the channel exit while the radial component of ion velocity at the channel inner wall location increased by 1300 m/s, and at the channel outer wall location the radial ion velocity remained unaffected. The ultimate exhaust velocity was not significantly affected by the inner magnet current.

  5. Roosters Rule: A Painted Paper Collage

    Science.gov (United States)

    Brady, Susan

    2011-01-01

    On perusing American collage artist Eric Carle's book, "Rooster's Off to See the World," at an annual school book fair, the author, mesmerized by the carnival of colors and collage on each page, thought "What a wonderful visual aid for a combination painting and collage unit." Her first-graders were involved in a painting unit, and knowing their…

  6. Detecting Corrosion Under Paint and Insulation

    Science.gov (United States)

    Bastin, Gary L.

    2011-01-01

    Corrosion is a major concern at the Kennedy Space Center in Florida due to the proximity of the center to the Atlantic Ocean and to salt water lagoons. High humidity, salt fogs, and ocean breezes, provide an ideal environment in which painted steel structures become corroded. Maintenance of painted steel structures is a never-ending process.

  7. 29 CFR 1915.33 - Chemical paint and preservative removers.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Chemical paint and preservative removers. 1915.33 Section... Preparation and Preservation § 1915.33 Chemical paint and preservative removers. (a) Employees shall be protected against skin contact during the handling and application of chemical paint and preservative...

  8. Self-Cleaning Mineral Paint for Application in Architectural Heritage

    Directory of Open Access Journals (Sweden)

    Sudipto Pal

    2016-10-01

    Full Text Available A mineral silicate paint has been developed for architectural heritage. To enhance durability, any type of organic additive has been avoided. Potassium silicate was the binder agent intended to give strong adherence and durability to stone and concretes. Incorporation of mainly anatase titanium dioxide was intended to act both as a white, bright pigment and as a photocatalyst. Reflectivity analyses on the paint in the visible-to-near infrared wavelength region show high solar heat reflection. The self-cleaning activity of the mineral paint was evaluated by the degradation of organic dyes under solar light irradiation. Anatase titania was effective in decomposing organic and airborne pollutants with the solar radiation. The optical properties and self-cleaning activity were compared with the organic binder-based paints and commercial paints. Developed paints possess high stability: since they contain only inorganic components that do not fade with exposure to solar radiation, photocatalytic self-cleaning capability further enhances such stability.

  9. Microanalysis of paint layers in polychrome sculptures

    International Nuclear Information System (INIS)

    Mendoza, A.; Falcucci, C.; Jaksic, M.

    2001-01-01

    Cross sections paint layers of polychromes sculpture of the 16 century, located at the City Museum of Havana and currently in the restoration process, have been analyzed by capillary based μXRF , μPIXE , SEM -EDX and light microscopy. Experimental parameters (geometry measurement time) of the capillary based μXRF set up (nominal end diameter equal to 10 μm) were optimized to achieve the resolution required for meaningful scintigraphic studies of the art and archaeological objects, Cumulative x-rays spectra for each layer were obtained in order to perform semi-quantitative analysis. The employed pigments were identified by the characteristics elements and the elemental maps precisely reproduced photographs obtained by means of light microscopy. In the case of nuclear microprobe, RBS for Stoichiometry analysis of paint layers was also performed. additional information on the organic materials was also obtained by chemical analysis. Complementary results obtained by using the analytical techniques are presented and discussed from the point of view of the restoration processes

  10. Micro-fabricated all optical pressure sensors

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Petersen, Søren Dahl; Østergaard, Christian

    2017-01-01

    Optical pressure sensors can operate in certain harsh application areas where the electrical pressure sensors cannot. However, the sensitivity is often not as good for the optical sensors. This work presents an all optical pressure sensor, which is fabricated by micro fabrication techniques, where...... the sensitivity can be tuned in the fabrication process. The developed sensor design, simplifies the fabrication process leading to a lower fabrication cost, which can make the all optical pressure sensors more competitive towards their electrical counterpart. The sensor has shown promising results and a linear...... pressure response has been measured with a sensitivity of 0.6nm/bar....

  11. Metal soaps in oil paint : Structure, mechanisms and dynamics

    NARCIS (Netherlands)

    Hermans, J.J.

    2017-01-01

    From a chemical point of view, oil paintings are not stable objects. Visually, changes in the appearance of an oil painting might be very slow, but over the course of centuries, chemical reactions and physical processes do affect the colour, texture and integrity of oil paint layers. This thesis

  12. Paint and Pregnancy

    Science.gov (United States)

    ... of paints used for industry, the arts, and hobbies. Years ago, lead and mercury were used in ... high amounts of toluene – higher exposure than a hobby or professional painter would likely have. I work ...

  13. Evaluation of stabilization of steel surface corrosion by paints

    Directory of Open Access Journals (Sweden)

    Aleš Dvořák

    2005-01-01

    Full Text Available This article deals with laboratory experiments focused on protective and stabilizing effects of paints designed to protect rusted steel surfaces. Two well-known paints (the Hammerite No.1 Rustbeater synthetic paint and the Antirezin water-soluble paint have been evaluated. The standardized tests according to ČSN have been used for the evaluation. Stabilization of rusted steel surface hasn’t been demonstrated during the tests. The SEM test method that covers micro-analysis of elements has been used for the evaluation as well.

  14. Impact of gas pressure on fission chamber sensitivity in Campbelling mode

    International Nuclear Information System (INIS)

    Geslot, B.; Blaise, P.; Loiseau, P.; Filliatre, P.; Jammes, C.; Breaud, S.; Villard, J-F.; Blanc-de-Lanaute, N.

    2013-06-01

    The study presented in this paper is based on measurements conducted in the MINERVE zero power reactor operated at CEA Cadarache with a CEA-made U-235 miniature fission chamber (8 mm in diameter) and obtained in both pulse and Campbelling modes. Our objective was to investigate the impact of the filling gas mixture and pressure on each operating mode, using the capacity of the chamber to be refilled with gas. Three gas mixtures were tested (pure Ar, Ar+4%N 2 and Ar+10%CH 4 ) with pressure ranging from 1 to 9 bars. The Mean Fission Product Charge (MFPC), which is the mean charge deposited in the gas by fission products, was obtained from pulse mode signals for each detector setting. It is shown the MFPC is another key parameter to optimize the detector neutron sensitivity, after the fissile coating cross section. Campbelling mode signal was acquired with the Fast Neutron Detector System (FNDS) recently developed by CEA and SCK·CEN. Interesting results were obtained which improve our knowledge of the detector operation. Firstly, it was found that the measurements obtained in both modes are very consistent. The MFPC as a function of the gas pressure was found to be not monotonic. Instead, it features a maximum between 3 and 4 bars. This behavior is expected if the detector does not operate in saturation regime. Indeed, our standard voltage bias of 300 V appeared to be not high enough so that the saturation regime is established. Saturation curves measured in Campbelling mode were fitted using a detector modeling in order to extrapolate the saturation regime MFPC, which came to be independent from the gas. Secondly, obtained results show that the measuring range in Campbelling mode with this detector starts from fission rates as low as a few thousand counts per second. So the so called overlapping range, in which both pulse and Campbelling modes are usable, is about one decade with our spectroscopy modules and more than two decades with fast counting electronic

  15. Reassessing the extent of the Q classification for containment paint

    International Nuclear Information System (INIS)

    Spires, G.

    1995-01-01

    A mounting number of site-specific paint debris transport and screen clogging analyses submitted to justify substandard containment paint work have been deemed persuasive by virtue of favorable U.S. Nuclear Regulatory Commission safety evaluation report (SER) findings. These lay a strong foundation for a standardized approach to redefining the extent to which paint in containment needs to be considered open-quotes Q.close quotes This information justifies an initiative by licensees to roll back paint work quality commitments made at the design phase. This paper questions the validity of the basic premise that all primary containment paint can significantly compromise core and containment cooling [emergency core cooling system/engineered safeguard feature (ECCS/ESF)]. It is posited that the physical extent of painted containment surfaces for which extant material qualification and quality control (QC) structures need apply can be limited to zones relatively proximate to ECCS/ESF suction points. For other painted containment surfaces, simplified criteria should be allowed

  16. A reference data set for validating vapor pressure measurement techniques: homologous series of polyethylene glycols

    Science.gov (United States)

    Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David

    2018-01-01

    To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass

  17. Electrical charging characteristics of the hetero layer film for reducing water-borne paint contamination in electrostatic rotary atomizers

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y.; Imanishi, T.; Yoshida, O.; Mizuno, A. [ABB Japan, Tokyo (Japan)

    2010-07-01

    The electrostatic rotary atomizer is the most efficient of all liquid spray painting methods. Its use minimizes the waste of paint and reduces emissions of volatile organic compounds (VOCs). Water-borne painting processes which use water-soluble paint also reduce VOC emissions, but the atomizer body is easily contaminated by the paint mists. The Institute of Electrical and Electronics Engineers (IEEE) considered the causes of water-borne paint contamination and presented the experimental results of a contamination proof system in which the atomizer is surrounded by the repelling film that is charged and repels the incoming paint droplets. Among the key factors for repelling film were electrical properties, such as low capacitance and high insulation to keep high surface potential. Charging uniformity was found to be among the most important characteristic to avoid contamination. The pulse electro-acoustic (PEA) method was used to check these features using space charge measurements inside the repelling film. It was concluded that hetero layer films have more uniform charging characteristics than single layer films.

  18. [Contemporary possibilities of intraocular pressure measurement].

    Science.gov (United States)

    Hornová, J; Baxant, A

    2013-10-01

    Authors introduced current possibilities of measuring intraocular pressure (IOP). A list of available methods of monitoring IOP is published; contact measurement method IOP directly on the cornea, but also over upper lid, methodology of minimal contact and non-contact measurement. Following contact methods are described; former measurements of IOP by impression Schiotz tonometer and the current methodology applanation. So far as the gold standard measurement Goldmann applanation tonometer (GAT) is considered, another methodology with applanation measurements are compared: Pascal dynamic contoured tonometer (DCT ), BioResonator - resonant applanation tonometer (ART ), digital applanation tonometer Tonopen and last hit: continuous measurement of IOP by Sensimed Triggerfish. Orientation and rapid assessment is palpation pressure control over the lid and measuring by tonometer Diaton. Rebound tonometer (RBT) iCare belongs to measurements with minimal contact, no need anesthetic drops and fluorescein, therefore a self - home version of IOP measurements (Icare ONE) is developed. Non-contact measurement of IOP by different pneumotonometers is popular for screening assessment of IOP. Reichert Ocular Response Analyzer (ORA) is a non-contact applanation IOP measurement and reveals additional properties of the cornea. In the discussion of a range methodology is evaluated, the experience of other authors and their own experience is compared. For monitoring of patients is necessary to select the most suitable methodology, measure repeatedly and accurately to allow long-term monitoring of intraocular pressure.

  19. Pressure pain sensitivity as a marker for stress and pressure pain sensitivity-guided stress management in women with primary breast cancer.

    Science.gov (United States)

    Axelsson, Christen K; Ballegaard, Søren; Karpatschof, Benny; Schousen, Peer

    2014-08-01

    To validate (1) Pressure Pain Sensitivity (PPS) as a marker for stress and (2) a PPS-guided intervention in women with primary Breast Cancer (BC). (1) A total of 58 women with BC were examined before and after 6 months of intervention. A control group of 165 women office employees was divided in a High Stress Group (HSG, n = 37) and a Low Stress Group (LSG, n = 128) to evaluate the association between PPS, questionnaire-related Quality of Life (QOL) and self-evaluated stress. (2) A PPS-guided stress management program (n = 40) was compared to a Psychosocial Group Intervention (PGI, n = 91) and no treatment (n = 86) with respect to a European Organization for Research and Treatment of Cancer (EORTC) questionnaire measured QOL. (1) Resting PPS and changes in PPS during the intervention period correlated significantly to EORTC and Short Form 36 (SF 36) main scores: (all p stress scores (all p stress. (2) The PPS-guided intervention group improved EORTC main score, pain and nausea, when compared to the control groups (all p stress. PPS-guided intervention improved QOL in women with breast cancer.

  20. Measurement of pressure pulsations in Francis turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kobro, Einar

    2010-11-15

    The work presented in this thesis involves preparation and execution of measurements on Francis runners. The measurements were performed by means of onboard measuring equipment both in model runners and full-scale prototype runners. Also, analysis of the measured data, and the discussion of the results, is presented. The measurements resulted in large data sets. These data sets were used by the author to investigate the dynamic pressure and strain in the runners. The results of the analysis can be used as input in future turbine design. Andritz Hydro AG has used the data for verification of their numerical simulation tools. In connection with the refurbishment of Tokke power plant, two model runners were made available for onboard pressure measurements. To investigate the dynamic pressure in these runners, methods for integration of pressure transducers in the runner blades needed to be developed. After initial difficulties during the preparation, successful measurements were obtained from both model runners. At Tokke power plant, both the original and replacement runners were made accessible for onboard pressure and strain gauge measurements. On the original Kvaerner Brug AS runner, the test was prepared and performed by the author. This test failed, due to water intrusion in the logging chain. The second test was performed on the Andritz Hydro AG replacement runner. This test was prepared and performed by the author in close cooperation with Andritz Hydro AG, and the results were successful. The analysis results from both model and prototype runners show that the wake leaving the guide vanes is the most severe source of dynamic pressure in the runner. The draft tube vortex rope pulsation propagates upstream the runner, but does not appear as a significant frequency in the runner strain measurements. (Author)

  1. Three-dimensional characterization of pigment dispersion in dried paint films using focused ion beam-scanning electron microscopy.

    Science.gov (United States)

    Lin, Jui-Ching; Heeschen, William; Reffner, John; Hook, John

    2012-04-01

    The combination of integrated focused ion beam-scanning electron microscope (FIB-SEM) serial sectioning and imaging techniques with image analysis provided quantitative characterization of three-dimensional (3D) pigment dispersion in dried paint films. The focused ion beam in a FIB-SEM dual beam system enables great control in slicing paints, and the sectioning process can be synchronized with SEM imaging providing high quality serial cross-section images for 3D reconstruction. Application of Euclidean distance map and ultimate eroded points image analysis methods can provide quantitative characterization of 3D particle distribution. It is concluded that 3D measurement of binder distribution in paints is effective to characterize the order of pigment dispersion in dried paint films.

  2. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  3. 2D imaging and 3D sensing data acquisition and mutual registration for painting conservation

    Science.gov (United States)

    Fontana, Raffaella; Gambino, Maria Chiara; Greco, Marinella; Marras, Luciano; Pampaloni, Enrico M.; Pelagotti, Anna; Pezzati, Luca; Poggi, Pasquale

    2005-01-01

    We describe the application of 2D and 3D data acquisition and mutual registration to the conservation of paintings. RGB color image acquisition, IR and UV fluorescence imaging, together with the more recent hyperspectral imaging (32 bands) are among the most useful techniques in this field. They generally are meant to provide information on the painting materials, on the employed techniques and on the object state of conservation. However, only when the various images are perfectly registered on each other and on the 3D model, no ambiguity is possible and safe conclusions may be drawn. We present the integration of 2D and 3D measurements carried out on two different paintings: "Madonna of the Yarnwinder" by Leonardo da Vinci, and "Portrait of Lionello d'Este", by Pisanello, both painted in the XV century.

  4. The Comparison Between Nmf and Ica in Pigment Mixture Identification of Ancient Chinese Paintings

    Science.gov (United States)

    Liu, Y.; Lyu, S.; Hou, M.; Yin, Q.

    2018-04-01

    Since the colour in painting cultural relics observed by our naked eyes or hyperspectral cameras is usually a mixture of several kinds of pigments, the mixed pigments analysis will be an important subject in the field of ancient painting conservation and restoration. This paper aims to find a more effective method to confirm the types of every pure pigment from mixture on the surface of paintings. Firstly, we adopted two kinds of blind source separation algorithms, which are independent component analysis and non-negative matrix factorization, to extract the pure pigment component from mixed spectrum respectively. Moreover, we matched the separated pure spectrum with the pigments spectra library built by our team to determine the pigment type. Furthermore, three kinds of data including simulation data, mixed pigments spectral data measured in laboratory, and the spectral data of an ancient painting were chosen to evaluate the performance of the different algorithms. And the accuracy was compared between the two algorithms. Finally, the experimental results show that non-negative matrix factorization method is more suitable for endmember extraction in the field of ancient painting conservation and restoration.

  5. THE COMPARISON BETWEEN NMF AND ICA IN PIGMENT MIXTURE IDENTIFICATION OF ANCIENT CHINESE PAINTINGS

    Directory of Open Access Journals (Sweden)

    Y. Liu

    2018-04-01

    Full Text Available Since the colour in painting cultural relics observed by our naked eyes or hyperspectral cameras is usually a mixture of several kinds of pigments, the mixed pigments analysis will be an important subject in the field of ancient painting conservation and restoration. This paper aims to find a more effective method to confirm the types of every pure pigment from mixture on the surface of paintings. Firstly, we adopted two kinds of blind source separation algorithms, which are independent component analysis and non-negative matrix factorization, to extract the pure pigment component from mixed spectrum respectively. Moreover, we matched the separated pure spectrum with the pigments spectra library built by our team to determine the pigment type. Furthermore, three kinds of data including simulation data, mixed pigments spectral data measured in laboratory, and the spectral data of an ancient painting were chosen to evaluate the performance of the different algorithms. And the accuracy was compared between the two algorithms. Finally, the experimental results show that non-negative matrix factorization method is more suitable for endmember extraction in the field of ancient painting conservation and restoration.

  6. Wave Shape and Impact Pressure Measurements at a Rock Coast Cliff

    Science.gov (United States)

    Varley, S. J.; Rosser, N. J.; Brain, M.; Vann Jones, E. C.

    2016-02-01

    Rock coast research focuses largely on wave behaviour across beaches and shore platforms but rarely considers direct wave interaction with cliffs. Hydraulic action is one of the most important drivers of erosion along rock coasts. The magnitude of wave impact pressure has been shown by numerical and laboratory studies to be related to the wave shape. In deep water, a structure is only subjected to the hydrostatic pressure due to the oscillating clapotis. Dynamic pressures, related to the wave celerity, are exerted in shallower water when the wave is breaking at the point of impact; very high magnitude, short duration shock pressures are theorised to occur when the approaching wavefront is vertical. As such, wave shape may directly influence the potential of the impact to weaken rock and cause erosion. Measurements of impact pressure at coastal cliffs are limited, and the occurrence and influence of this phenomenon is currently poorly constrained. To address this, we have undertaken a field monitoring study on the magnitude and vertical distribution of wave impact pressures at the rocky, macro-tidal coastline of Staithes, North Yorkshire, UK. A series of piezo-resistive pressure transducers and a camera were installed at the base of the cliff during low tide. Transducers were deployed vertically up the cliff face and aligned shore-normal to capture the variation in static and dynamic pressure with height during a full spring tidal cycle. Five minute bursts of 5 kHz pressure readings and 4 Hz wave imaging were sampled every 30 minutes for six hours during high tide. Pressure measurements were then compensated for temperature and combined with wave imaging to produce a pressure time series and qualitative wave shape category for each wave impact. Results indicate the presence of a non-linear relationship between pressure impact magnitude, the occurrence of shock pressures, wave shape and tidal stage, and suggest that breaker type on impact (and controls thereof) may

  7. Deuterium oxide normalizes blood pressure and vascular calcium uptake in Dahl salt-sensitive hypertensive rats

    International Nuclear Information System (INIS)

    Vasdev, S.; Prabhakaran, V.; Sampson, C.A.

    1990-01-01

    This study examined the effect of 25% deuterium oxide in drinking water on systolic blood pressure, uptakes of calcium, and rubidium 86 by aortas of Dahl salt-sensitive rats on 0.4% (low) and 8% (high) sodium chloride (salt) diet. Twenty-four rats were divided into four groups. Groups I and II were on the low salt diet and groups III and IV on the high salt diet from 6 weeks of age. Additionally, at 10 weeks of age groups I and III were placed on 100% water and groups II and IV on 25% deuterium oxide. At 14 weeks, systolic blood pressure, uptakes of calcium, and rubidium 86 by aortas were significantly higher (p less than 0.01) in rats on the high salt diet as compared with those on the low salt diet. Deuterium oxide intake normalized systolic blood pressure and aortic calcium uptake but not aortic rubidium 86 uptake in hypertensive rats on the high salt diet. Deuterium oxide had no effect on blood pressure or aortic calcium uptake in rats on the low salt diet. The parallel increase in systolic blood pressure and vascular calcium uptake suggests that increased calcium uptake mechanisms are associated with hypertension in salt-sensitive Dahl rats. Furthermore, deuterium oxide appears to normalize elevated blood pressure in salt-sensitive hypertensive rats by normalizing elevated vascular (aortic) calcium uptake

  8. MEMS technology sensors as a more advantageous technique for measuring foot plantar pressure and balance in humans

    OpenAIRE

    Sanz Morère, C. (Clara); Surażyński, Ł. (Łukasz); Rodrigo Pérez-Tabernero, A. (Ana); Vihriälä, E. (Erkki); Myllylä, T. (Teemu)

    2016-01-01

    Abstract Locomotor activities are part and parcel of daily human life. During walking or running, feet are subjected to high plantar pressure, leading sometimes to limb problems, pain, or foot ulceration. A current objective in foot plantar pressure measurements is developing sensors that are small in size, lightweight, and energy efficient, while enabling high mobility, particularly for wearable applications. Moreover, improvements in spatial resolution, accuracy, and sensitivity are of i...

  9. Development of Screenable Pressure Sensitive Adhesives

    Energy Technology Data Exchange (ETDEWEB)

    Steven J. Severtson

    2003-11-29

    An industrial research area of high activity in recent years has been the development of pressure sensitive adhesive (PSA) products that do not interfere with the processing of post-consumer waste. The problem of PSA contamination is arguably the most important technical challenge in expanding the use of recycled fiber. The presence of PSAs in recovered paper creates problems that reduce the efficiency of recycling and papermaking operations and diminish product quality. The widespread use of PSAs engineered to avoid these problems, often referred to as environmentally benign PSAs, could greatly increase the commercial viability of utilizing secondary fiber. Much of the research efforts in this area have focused on the development of PSAs that are designed for enhanced removal with cleaning equipment currently utilized by recycling plants. Most removal occurs at the pressure screens with the size and shape of residual contaminants in the process being the primary criteria for their separation. A viable approach for developing environmentally benign PSAs is their reformulation to inhibit fragmentation. The reduction of adhesives to small particles occurs almost exclusively during repulping; a process in which water and mechanical energy are used to swell and reduce paper products to their constituent fiber. Engineering PSA products to promote the formation of larger adhesive particles during repulping will greatly enhance their removal and reduce or eliminate their impact on the recycling process.

  10. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  11. A Bayesian ensemble of sensitivity measures for severe accident modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hoseyni, Seyed Mohsen [Department of Basic Sciences, East Tehran Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Di Maio, Francesco, E-mail: francesco.dimaio@polimi.it [Energy Department, Politecnico di Milano, Via La Masa 34, 20156 Milano (Italy); Vagnoli, Matteo [Energy Department, Politecnico di Milano, Via La Masa 34, 20156 Milano (Italy); Zio, Enrico [Energy Department, Politecnico di Milano, Via La Masa 34, 20156 Milano (Italy); Chair on System Science and Energetic Challenge, Fondation EDF – Electricite de France Ecole Centrale, Paris, and Supelec, Paris (France); Pourgol-Mohammad, Mohammad [Department of Mechanical Engineering, Sahand University of Technology, Tabriz (Iran, Islamic Republic of)

    2015-12-15

    Highlights: • We propose a sensitivity analysis (SA) method based on a Bayesian updating scheme. • The Bayesian updating schemes adjourns an ensemble of sensitivity measures. • Bootstrap replicates of a severe accident code output are fed to the Bayesian scheme. • The MELCOR code simulates the fission products release of LOFT LP-FP-2 experiment. • Results are compared with those of traditional SA methods. - Abstract: In this work, a sensitivity analysis framework is presented to identify the relevant input variables of a severe accident code, based on an incremental Bayesian ensemble updating method. The proposed methodology entails: (i) the propagation of the uncertainty in the input variables through the severe accident code; (ii) the collection of bootstrap replicates of the input and output of limited number of simulations for building a set of finite mixture models (FMMs) for approximating the probability density function (pdf) of the severe accident code output of the replicates; (iii) for each FMM, the calculation of an ensemble of sensitivity measures (i.e., input saliency, Hellinger distance and Kullback–Leibler divergence) and the updating when a new piece of evidence arrives, by a Bayesian scheme, based on the Bradley–Terry model for ranking the most relevant input model variables. An application is given with respect to a limited number of simulations of a MELCOR severe accident model describing the fission products release in the LP-FP-2 experiment of the loss of fluid test (LOFT) facility, which is a scaled-down facility of a pressurized water reactor (PWR).

  12. Nd:YVO{sub 4} laser removal of graffiti from granite. Influence of paint and rock properties on cleaning efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Rivas, T., E-mail: trivas@uvigo.es [Dpto. Ingenieria de los Recursos Naturales y Medio Ambiente. Universidad de Vigo, Lagoas-Marcosende s/n, 36310 Vigo (Spain); Pozo, S. [Dpto. Ingenieria de los Recursos Naturales y Medio Ambiente. Universidad de Vigo, Lagoas-Marcosende s/n, 36310 Vigo (Spain); Fiorucci, M.P.; Lopez, A.J.; Ramil, A. [Centro de Investigacions Tecnoloxicas (CIT), Universidade da Coruna, 15403 Ferrol (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Cleaning using NdYVO{sub 4} laser at 355 nm of four different graffiti colours applied on granites. Black-Right-Pointing-Pointer Analysis of the influence of paint composition and properties of rocks on the process. Black-Right-Pointing-Pointer Composition of the paints and, in turn reflectance, determine the removal effectiveness. Black-Right-Pointing-Pointer The laser removal is not conditioned by properties of the stones. - Abstract: This paper presents the cleaning efficiency results for four differently coloured graffiti paints applied to two types of granitic stone by Nd:YVO{sub 4} laser at 355 nm. The paints were characterized in terms of mineralogy and chemistry using x-ray fluorescence, X-ray diffraction, Fourier transform infrared (FTIR) spectroscopy and scanning electron microscope (SEM); paint absorbance in the ultraviolet-visible-infrared range (200-2000 nm) was also assessed. The studied granites had different mineralogy, texture and porosity properties. Cleaning efficiency was evaluated by polarized microscopy, SEM, FTIR spectroscopy and spectrophotometer colour measurements. The results indicate differences in the effectiveness of surface cleaning for the blue, red and black paints as opposed to the silver paint, mainly attributed to chemical composition. No evidence was found that the granite properties had a bearing on laser effectiveness, although the degree, type and spatial distribution of transgranular fissures in the stone affected the overall assessment of cleaning effectiveness. Polarized light microscopy observations and colour measurements showed that the intensity and distribution of fissures affect the depth of paint penetration, ultimately affecting the cleaning efficiency for both granites.

  13. THE ART OF POETRY AND PAINTING: NEW SUBJETIVITIES IN POST-INDEPENDENCE ANGOLA

    Directory of Open Access Journals (Sweden)

    Carmen Lúcia Tindó Secco

    2008-08-01

    Full Text Available The art of poetry and painting: new poetic and pictorial subjectivities in Angola after its Independence. The post 80's decades and the rising of other forms of revolution in the aesthetic language. Themes and creative literary procedures: the existential reason, the individual sensitivities, the literary imagination. The presence of love, the myths, of History, of the dreams in the Angolan arts of the last decades as strategies of cultural resistance.

  14. Pressure History Measurement in a Microwave Beaming Thruster

    International Nuclear Information System (INIS)

    Oda, Yasuhisa; Ushio, Masato; Komurasaki, Kimiya; Takahashi, Koji; Kasugai, Atsushi; Sakamoto, Keishi

    2006-01-01

    In a microwave beaming thruster with a 1-dimensional nozzle, plasma and shock wave propagates in the nozzle absorbing microwave power. In this study, pressure histories in the thruster are measured using pressure gauges. Measured pressure history at the thruster wall shows constant pressure during plasma propagation in the nozzle. The result of measurement of the propagating velocities of shock wave and plasma shows that both propagate in the same velocity. These result shows that thrust producing model of analogy of pulse detonation engine is successful for the 1D thruster

  15. The Conservation of Panel paintings

    DEFF Research Database (Denmark)

    Until the early 17th century almost all portable paintings were created on wood supports, including masterpieces by famous painters, ranging from Giotto to Dürer to Rembrandt. The structural conservation of these paintings requires specific knowledge and skills as the supports are susceptible...... and conservation of these artworks. The Netherlands Organisation for Scientific Research (NWO) and the Rijksmuseum Amsterdam brought together a group of experts from different disciplines to recommend specific areas in the field that would benefit from systematic research. The experts concluded that targeted...

  16. THz reflectometric imaging of medieval wall paintings

    DEFF Research Database (Denmark)

    Dandolo, Corinna Ludovica Koch; Jepsen, Peter Uhd

    2013-01-01

    Terahertz time-domain reflectometry has been applied to the investigation of a medieval Danish wall painting. The technique has been able to detect the presence of carbonblack layer on the surface of the wall painting and a buried insertion characterized by high reflectivity values has been found...

  17. The Efforts to Increase Artistic Sensitivity of Unesa’s Art Education Students by Painting with Watercolor and Wax Media

    Directory of Open Access Journals (Sweden)

    Winarno Winarno

    2016-04-01

    Full Text Available Artistic abilities of students who had been enrolled in Arts Educations Department of UNESA, in general, were a lack in realizing artistic aspect. It created the problems in learning and teaching of art. The purpose of this research was to increase the students’ sensitivity in creating their work. One way to solve this problem was by doing the work as much as possible, but the results were not fully obtained. So far, there were no standardized guidelines to help the improvement of the work quality in term artistic achievement level. While it became a problem in learning, there was an effort to find a simple and effective way by mixed media watercolor paint and wax. The method in this research was the design of class action research, where the research was conducted in the learning process of each cycle. Every cycle consists of planning, implementation, observation, and reflection. The result of this research shows an increasing of artistic quality regarding practical grades of art. However, there are other alternatives must be sought to increase students’ ability to create, view, appreciate something that is artistic. 

  18. PORTRAIT ART IN NATIONAL PAINTING (1959-1970

    Directory of Open Access Journals (Sweden)

    LOZOVANU VLADIMIR

    2016-12-01

    Full Text Available The author of this article describes the portrait in national painting during the 1960s, years that marked political, social and cultural changes that contributed to the spiritual emancipation of the creative personality and the formation of new plastic tendencies in the field of portrait painting. He also describes the famous artists` portrait painting creations that have contributed to the spiritual emancipation of the creating personality and the establishment of new plastic tendencies in the fi eld of portrait painting. In the article, there are examples of representative portraits that are described in the context of the period when they were created. The author identifi es the methods, techniques, ideas and aspirations used in the works of plastic artists for drawing portraits that allow to form an ample conception about this phenomenon. The presented information is useful to artists, teachers and students who work in the field of visual art.

  19. Characterization of the Teotihuacan mural painting: application of the external particle beam as non destructive technique

    International Nuclear Information System (INIS)

    Martinez, C.; Manzanilla, L.; Ruvalcaba, J.L.; Ontalba, M.A.

    2005-01-01

    The characterization of technical indicators contained in the painting mural should follow a minim methodology from their discovery in the archaeological excavations until their analysis in the laboratory, with the purpose of rescuing diagnostic elements that mark the stages of socio cultural development in the towns. With this spirit it was carried out the present study analyzing some fragments of the Teotihuacan mural painting. The analysis consisted on applying some of the analytical techniques with particle beams used for archaeometry like the Proton induced X-ray emission (PIXE) and the particle elastic backscattering (RBS), due to it is treated of complementary techniques, very sensitive, of multielemental character, but mainly because its are non destructive analytical techniques. (Author)

  20. A review on paint sludge from automotive industries: Generation, characteristics and management.

    Science.gov (United States)

    Salihoglu, Guray; Salihoglu, Nezih Kamil

    2016-03-15

    The automotive manufacturing process results in the consumption of several natural sources and the generation of various types of wastes. The primary source of hazardous wastes at an automotive manufacturing plant is the painting process, and the major waste fraction is paint sludge, which is classified with EU waste code of 080113* implying hazardous characteristics. The amount of the paint sludge generated increases every year with the worldwide increase in the car production. The characteristics of the paint sludge, which mainly designate the management route, are mainly determined by the type of the paint used, application technique employed, and the chemicals applied such as flocculants, detackifiers, pH boosters, antifoam agents, and biocides as well as the dewatering techniques preferred. Major routes for the disposal of the paint sludges are incineration as hazardous waste or combustion at cement kilns. Because of high dissolved organic carbon content of the paint, the paint sludge cannot be accepted by landfills according to European Union Legislations. More investigations are needed in the field of paint sludge recycling such as recycling it as a new paint or as other formulations, or making use of the sludge for the production of construction materials. Research on the applicability of the paint sludge in composting and biogasification can also be useful. Ongoing research is currently being conducted on new application techniques to increase the effectiveness of paint transfer, which helps to prevent the generation of paint sludge. Advancements in paint and coating chemistry such as the reduction in the coating layers with its thickness also help to decrease the level of paint sludge generation. Investigations on the effects of the chemicals on the recycling potential of paint sludges and consideration of these effects by the chemical manufacturer companies would be extremely important. This review presents the formation of paint sludge, the factors

  1. Push-Pull Ventilation in a Painting Shop for Large Steel Constructions

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per

    This paper describes the analysis of a push-pull ventilation system for a painting shop that is used for painting steel chimneys and windmill towers.......This paper describes the analysis of a push-pull ventilation system for a painting shop that is used for painting steel chimneys and windmill towers....

  2. Are Shaman Paintings Material Religion or Religious Art?

    Directory of Open Access Journals (Sweden)

    Jong-chun Park

    2017-12-01

    Full Text Available Laurel Kendall, Jongsung Yang, and Yul Soo Yoon. God Pictures in Korean Contexts: The Ownership and Meaning of Shaman Paintings. Honolulu: University of Hawai'i Press, 2015. God Pictures in Korean Contexts: The Ownership and Meaning of Shaman Paintings is a pioneering work, one that explores the proverbial “road not taken” by previous research on the subject. The authors situate “the lives of Korean shaman paintings [musindo] in a complex South Korean world; in shaman shrines, private collections, and museums." Incorporating their vivid experiences in the field, authors Laurel Kendall, anthropologist and curator at the American Museum of Natural History; Jongsung Yang, collector and director of the Museum of Shamanism in Seoul; and Yul Soo Yoon, art historian and director of the Gahoe Museum in Seoul, investigate not merely the religious meanings and functions of shaman paintings, but how these meanings and functions are accepted, appropriated, and even created, depending on the interests of various participants—shamans, painters, collectors of shaman paintings, and so on—who are relevant to these visual forms of expressive culture.

  3. Development of carbon nanotube paste for dye-sensitized solar cells

    Science.gov (United States)

    Tsuji, Masaya; Sugiyama, Seiichi; Oya, Takahide

    2012-09-01

    We propose a new type of dye-sensitized solar cell (DSC) using carbon nanotubes (CNTs). Recently, global warming due to CO2 generated from power plants, cars, and so on has received much attention. Therefore, clean power, e.g., solar power, is gaining in importance. In this study, we focused on a DSC that uses CNTs. Generally, sensitized dyes on semiconducting and metallic electrodes are used for constructing DSCs. In contrast, CNTs have many excellent properties. In particular, they have metallic and semiconducting properties that are used for the electrodes of DSCs. Therefore, we applied CNTs for fabricating a new "painting-type" DSC with semiconducting and metallic electrodes. CNTs are dispersed in water with surfactant to prepare CNT-paste for painting. This resulting CNT-paste has the same properties as a normal CNT. A DSC is comprised of two electrodes. One is a semiconducting electrode with a sensitized dye and another is a metallic one, as mentioned above. We fabricated the two electrodes by painting the CNT-paste onto substrates. Thus, this type of DSC can be applied to various objects, for example, the wall and car and housetop. An electrolyte is required and must be put between the electrodes. The method for fabricating a painting type DSC is very simple. First, two versions of the paste are used. One is a semiconducting CNT-paste that adsorbs a dye and the other is a CNT-paste without a dye. Second, we paint each paste onto two substrates. Finally, the two substrates are stacked. We drip about 10μl of an electrolyte onto the stacked substrates and irradiate them with solar light (1300 W/m2). An electromotive force (EMF) is generated by excited electrons from the dye, which are adsorbed on the semiconducting electrode. The maximum EMF reached about 250 mV and the current reached about 10 μA. These results indicate that the proposed painting-type DSC can be used a new type of solar cell.

  4. The American Heart Association Scientific Statement on salt sensitivity of blood pressure: Prompting consideration of alternative conceptual frameworks for the pathogenesis of salt sensitivity?

    Science.gov (United States)

    Kurtz, Theodore W; DiCarlo, Stephen E; Pravenec, Michal; Morris, R Curtis

    2017-11-01

    : Recently, the American Heart Association (AHA) published a scientific statement on salt sensitivity of blood pressure which emphasized a decades old conceptual framework for the pathogenesis of this common disorder. Here we examine the extent to which the conceptual framework for salt sensitivity emphasized in the AHA Statement accommodates contemporary findings and views of the broader scientific community on the pathogenesis of salt sensitivity. In addition, we highlight alternative conceptual frameworks and important contemporary theories of salt sensitivity that are little discussed in the AHA Statement. We suggest that greater consideration of conceptual frameworks and theories for salt sensitivity beyond those emphasized in the AHA Statement may help to advance understanding of the pathogenesis of salt-induced increases in blood pressure and, in consequence, may lead to improved approaches to preventing and treating this common disorder.

  5. 33 CFR 118.140 - Painting bridge piers.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Painting bridge piers. 118.140 Section 118.140 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.140 Painting bridge piers. The District Commander may require...

  6. Pressure field in measurement section of wind tunnel

    Directory of Open Access Journals (Sweden)

    Hnidka Jakub

    2017-01-01

    Full Text Available The University of Defence in Brno has a new low-speed wind tunnel. In order to confirm the quality of the wind inside of the measurement section, several measurements of the dynamic pressure have been performed with the Pitot-static tube. The pressure fields are then analysed and quality of the field is evaluated. Measurement of a pressure drop on the body of a standing helicopter was conducted.

  7. Capabilities and limitations of handheld Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for the analysis of colourants and binders in 20th-century reverse paintings on glass

    Science.gov (United States)

    Steger, Simon; Stege, Heike; Bretz, Simone; Hahn, Oliver

    2018-04-01

    A non-invasive method has been carried out to show the capabilities and limitations of Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for identifying of colourants and binders in modern reverse glass paintings. For this purpose, the reverse glass paintings "Zwei Frauen am Tisch" (1920-22), "Bäume" (1946) (both by Heinrich Campendonk), "Lofoten" (1933) (Edith Campendonk-van Leckwyck) and "Ohne Titel" (1954) (Marianne Uhlenhuth), were measured. In contrast to other techniques (e.g. panel and mural painting), the paint layers are applied in reverse succession. In multi-layered paint systems, the front paint layer may no longer be accessible. The work points out the different spectral appearance of a given substance (gypsum, basic lead white) in reverse glass paintings. However, inverted bands, band overlapping and derivative-shaped spectral features can be interpreted by comparing the spectra from the paintings with spectra from pure powders and pigment/linseed oil mock-ups. Moreover, the work focuses on this method's capabilities in identifying synthetic organic pigments (SOP). Reference spectra of three common SOP (PG7, PY1, PR83) were obtained from powders and historical colour charts. We identified PR83 and PY1 in two reverse glass paintings, using the measured reference spectra. The recorded DRIFTS spectra of pure linseed oil, gum Arabic, mastic, polyvinyl acetate resin and bees wax can be used to classify the binding media of the measured paintings.

  8. On the study of oil paint adhesion on optically transparent glass: Conservation of reverse paintings on glass

    International Nuclear Information System (INIS)

    Bayle, M.; Waugh, D.G.; Colston, B.J.; Lawrence, J.

    2015-01-01

    Highlights: • Adhesion characteristics analysed with respect to reverse paintings on glass. • Physical properties of surfaces and pigments found to affect cohesion and adhesion. • Environmental effects on pigment adhesion to glass have been documented. • Vermillion pigment hardest compared to other pigments, especially with adhesives. • Wettability used to assess adhesion properties relating to reverse paintings on glass. - Abstract: Reverse painting on glass is a technique which consists of applying a cold paint layer on the reverse-side of glass. The main challenge facing these artworks is the fragile adhesion of the pictorial layer – a simple movement can modify the appearance of the painting. This paper details a study into the adhesion parameters of pigments on glass and the comparison between different pigments. The relationships between the binder (linseed oil) with pigments and the glass with or without the use of an adhesive are studied. Physical analyses by surface characterisation have been carried out to better understand the influence of the pigment. The use of a sessile drop device, optical microscopy, scanning electron microscopy (SEM), a surface 3D profiler and a pencil hardness scratch tester were necessary to establish a comparison of the pictorial layer adhesion. A comparison of the effect of two adhesives, namely ox gall and gum arabic, has shown that the adhesion is not only linked to the physical parameters but that possible chemical reactions can influence the results. Finally, a treatment based on humidity-extreme storage has shown the weakness of some pictorial layers.

  9. On the study of oil paint adhesion on optically transparent glass: Conservation of reverse paintings on glass

    Energy Technology Data Exchange (ETDEWEB)

    Bayle, M. [Historic and Ancient Materials Group, School of Chemistry, University of Lincoln, Brayford Pool, Lincoln LN6 7TS (United Kingdom); Waugh, D.G., E-mail: d.waugh@chester.ac.uk [Laser Engineering and Manufacturing Research Centre, Faculty of Science and Engineering, University of Chester, Thornton Science Park, Ince, Chester CH2 4NU (United Kingdom); Colston, B.J. [Historic and Ancient Materials Group, School of Chemistry, University of Lincoln, Brayford Pool, Lincoln LN6 7TS (United Kingdom); Lawrence, J. [Laser Engineering and Manufacturing Research Centre, Faculty of Science and Engineering, University of Chester, Thornton Science Park, Ince, Chester CH2 4NU (United Kingdom)

    2015-12-01

    Highlights: • Adhesion characteristics analysed with respect to reverse paintings on glass. • Physical properties of surfaces and pigments found to affect cohesion and adhesion. • Environmental effects on pigment adhesion to glass have been documented. • Vermillion pigment hardest compared to other pigments, especially with adhesives. • Wettability used to assess adhesion properties relating to reverse paintings on glass. - Abstract: Reverse painting on glass is a technique which consists of applying a cold paint layer on the reverse-side of glass. The main challenge facing these artworks is the fragile adhesion of the pictorial layer – a simple movement can modify the appearance of the painting. This paper details a study into the adhesion parameters of pigments on glass and the comparison between different pigments. The relationships between the binder (linseed oil) with pigments and the glass with or without the use of an adhesive are studied. Physical analyses by surface characterisation have been carried out to better understand the influence of the pigment. The use of a sessile drop device, optical microscopy, scanning electron microscopy (SEM), a surface 3D profiler and a pencil hardness scratch tester were necessary to establish a comparison of the pictorial layer adhesion. A comparison of the effect of two adhesives, namely ox gall and gum arabic, has shown that the adhesion is not only linked to the physical parameters but that possible chemical reactions can influence the results. Finally, a treatment based on humidity-extreme storage has shown the weakness of some pictorial layers.

  10. Identification of the chemical inventory of different paint types applied in nuclear facilities

    International Nuclear Information System (INIS)

    Sabrina Tietze; Foreman, M.R.St.J.; Ekberg, CH.H.; Chalmers University of Technology, Chemical and Biological Engineering, Goeteborg; Dongen van, B.E.

    2013-01-01

    The floors, concrete walls and many of the metal surfaces in nuclear power plant containments are coated with zinc primers or paint films to preserve the metal surfaces and simplify decontamination in the containment after the occurrence of a severe nuclear incident or accident. A chemical examination of paint films from different nuclear installations out of operation, as well as current operating ones, reveals that different types of paints are used whose composition can vary significantly. Results obtained for one type of paint at a certain nuclear site are in most cases unlikely to be comparable with sites painted with another type of paint. During normal operation and particularly during nuclear accidents, the paints will degrade under the high temperature, steam and irradiation influence. As paint and its degradation products can act as sources and depots for volatile iodine compounds, the type and aging conditions of the paint films will have a significant impact on the source term of the volatile fission product iodine. Thus, great care should be taken when extrapolating any results obtained for the interaction of radioactive iodine with one paint product to a different paint product. The main focus of the study is a comparison of the chemical profile of paint films applied in Swedish nuclear power plants. Teknopox Aqua V A, an epoxy paint recently used at Ringhals 2, and an emulsion paint used in the scrubber buildings of Ringhals 1-4 are compared with a paint film from Barsebaeck nuclear power plant unit 1 that had been aged under real reactor conditions for 20 years. In addition, two paint films, an emulsion and a gloss paint, used in an international nuclear fuel reprocessing facility, are compared with the paints from the Swedish nuclear power plants. (author)

  11. Aerial vehicle with paint for detection of radiological and chemical warfare agents

    Science.gov (United States)

    Farmer, Joseph C.; Brunk, James L.; Day, S. Daniel

    2013-04-02

    A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.

  12. Are Shaman Paintings Material Religion or Religious Art?

    OpenAIRE

    Jong-chun Park

    2017-01-01

    Laurel Kendall, Jongsung Yang, and Yul Soo Yoon. God Pictures in Korean Contexts: The Ownership and Meaning of Shaman Paintings. Honolulu: University of Hawai'i Press, 2015. God Pictures in Korean Contexts: The Ownership and Meaning of Shaman Paintings is a pioneering work, one that explores the proverbial “road not taken” by previous research on the subject. The authors situate “the lives of Korean shaman paintings [musindo] in a complex South Korean world; in shaman shrines, private co...

  13. Pressure pain sensitivity topographical maps reveal bilateral hyperalgesia of the hands in patients with unilateral carpal tunnel syndrome.

    Science.gov (United States)

    Fernández-de-Las-Peñas, César; Madeleine, Pascal; Martínez-Perez, Almudena; Arendt-Nielsen, Lars; Jiménez-García, Rodrigo; Pareja, Juan A

    2010-08-01

    To assess topographical pressure pain sensitivity maps of the hand in patients with unilateral carpal tunnel syndrome (CTS) as compared with healthy subjects. A total of 20 women with CTS (ages 32-52 years) and 20 healthy matched women (ages 32-51 years) were recruited. Pressure pain thresholds (PPTs) were measured bilaterally over 30 locations of the palm of each hand by an assessor blinded to the subjects' conditions. Patients showed lower PPTs in both hands in all of the measurement points as compared with controls (P < 0.001 for all). PPTs were lower in those points over the proximal phalanx of the fingers and the thenar eminency as compared with those points located over the distal phalanx of the fingers (P < 0.001). CTS patients showed lower PPT levels in dermatomes C6, C7, and C8 when compared with healthy controls (P < 0.001 for all), but without differences between dermatomes (P = 0.4). PPT was negatively correlated with both hand pain intensity and duration of symptoms (P < 0.001 for all). Our findings revealed bilateral generalized pressure pain hyperalgesia in unilateral CTS because lower PPT levels were found in all of the points. The pressure pain hyperalgesia was not uniformly distributed since PPTs were lower in points over the proximal phalanx of the fingers and the thenar eminency as compared with those points located over the distal phalanx of the fingers. The decrease in PPT levels was associated with the intensity and the duration of the pain symptoms, supporting a role of both peripheral and central sensitization mechanisms in this pain condition.

  14. Non-destructive synchrotron X-ray diffraction mapping of a Roman painting

    International Nuclear Information System (INIS)

    Dooryhee, E.; Anne, M.; Hodeau, J.-L.; Martinetto, P.; Rondot, S.; Bardies, I.; Salomon, J.; Walter, P.; Vaughan, G.B.M.

    2005-01-01

    The history and the properties of materials are deduced not only from their elemental and molecular signatures, but also from their exact phase compositions, and from the structures and the defects of their constituents. Here we implement a non-destructive synchrotron X-ray based method, which combines both the quantitative structural content of diffraction and the imaging mode. As a demonstration case, the pigments of a Roman wall painting are examined. The joined elemental and mineral maps mimic the major features of the painting. Different structural phases made of common atomic elements are differentiated. Textures and graininess are measured and related to the artist's know-how. (orig.)

  15. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  16. Various high precision measurements of pressure in atomic energy industry

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Inoue, Akira; Hosoma, Takashi; Tanaka, Izumi; Gabane, Tsunemichi.

    1987-01-01

    As for the pressure measurement in atomic energy industry, it is mostly the measurement using differential pressure transmitters and pressure transmitters for process measurement with the general accuracy of measurement of 0.2 - 0.5 % FS/year. However, recently for the development of nuclear fusion reactors and the establishment of nuclear fuel cycle accompanying new atomic energy technology, there are the needs of the pressure measurement having higher accuracy of 0.01 % FS/year and high resolution, and quartz vibration type pressure sensors appeared. New high accuracy pressure measurement techniques were developed by the advance of data processing and the rationalization of data transmission. As the results, the measurement of the differential pressure of helium-lithium two-phase flow in the cooling system of nuclear fusion reactors, the high accuracy measuring system for the level of plutonium nitrate and other fuel substance in tanks in fuel reprocessing and conversion, the high accuracy measurement of atmospheric pressure and wind velocity in ducts, chimneys and tunnels in nuclear facilities and so on became feasible. The principle and the measured data of quartz vibration type pressure sensors are shown. (Kako, I.)

  17. Alteration of blue pigment in artificial iris in ocular prosthesis: effect of paint, drying method and artificial aging.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Fernandes, Aline Úrsula Rocha; dos Santos, Daniela Micheline; Hadadd, Marcela Filié; Moreno, Amália; Pesqueira, Aldiéris Alves

    2011-02-01

    The artificial iris is the structure responsible for the dissimulation and aesthetics of ocular prosthesis. The objective of the present study was to evaluate the color stability of artificial iris of microwaveable polymerized ocular prosthesis, as a function of paint type, drying method and accelerated aging. A total of 40 discs of microwaveable polymerized acrylic resin were fabricated, and divided according to the blue paint type (n = 5): hydrosoluble acrylic, nitrocellulose automotive, hydrosoluble gouache and oil paints. Paints where dried either at natural or at infrared light bulb method. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. Painting was performed in one surface of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 h. A reflective spectrophotometer was used to evaluate color changes. Data were evaluated by 3-way repeated-measures ANOVA and the Tukey HSD test (α = 0.05). All paints suffered color alteration. The oil paint presented the highest color resistance to artificial aging regardless of drying method. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Pursuing atmospheric water vapor retrieval through NDSA measurements between two LEO satellites: evaluation of estimation errors in spectral sensitivity measurements

    Science.gov (United States)

    Facheris, L.; Cuccoli, F.; Argenti, F.

    2008-10-01

    NDSA (Normalized Differential Spectral Absorption) is a novel differential measurement method to estimate the total content of water vapor (IWV, Integrated Water Vapor) along a tropospheric propagation path between two Low Earth Orbit (LEO) satellites. A transmitter onboard the first LEO satellite and a receiver onboard the second one are required. The NDSA approach is based on the simultaneous estimate of the total attenuations at two relatively close frequencies in the Ku/K bands and of a "spectral sensitivity parameter" that can be directly converted into IWV. The spectral sensitivity has the potential to emphasize the water vapor contribution, to cancel out all spectrally flat unwanted contributions and to limit the impairments due to tropospheric scintillation. Based on a previous Monte Carlo simulation approach, through which we analyzed the measurement accuracy of the spectral sensitivity parameter at three different and complementary frequencies, in this work we examine such accuracy for a particularly critical atmospheric status as simulated through the pressure, temperature and water vapor profiles measured by a high resolution radiosonde. We confirm the validity of an approximate expression of the accuracy and discuss the problems that may arise when tropospheric water vapor concentration is lower than expected.

  19. 4D Visualization of Painted Sculpture and Murals

    Science.gov (United States)

    Ai, M. Y.; Tong, H.; Shen, L.; Wang, R. X.; Zhang, F.; Zhang, Z. C.; Hu, Q. W.; Zhu, Y. X.; Zhang, H.

    2015-08-01

    Most cultural heritage applications address visualization with using various media or platforms: desktop-based multimedia presentations, museum kiosks, or videos produced with computer animation. However, these techniques can not directly reveal or show the course that the colorful surface of painted sculpture and murals becomes faint along with the change of the climate and time. Most current techniques just preserve the current appearance and disseminate the current situation of the painted sculpture and murals. The course how these forms of cultural heritage change along the time has not been visualized. In this paper we developed an approach to modelling of painted sculpture and murals that has undergone changes over the years. Different hypotheses has also be given if there is uncertainty. A painted sculpture of Mogao Grottoes is used to demonstate this approach.

  20. 13 CFR 120.173 - Lead-based paint.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Lead-based paint. 120.173 Section 120.173 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Policies Applying to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If...

  1. Nanoclays for polymer nanocomposites, paints, inks, greases

    Indian Academy of Sciences (India)

    ... rheological modifier for paints, inks and greases, drug delivery vehicle for controlled release of therapeutic agents, and nanoclays for industrial waste water as well as potable water treatment to make further step into green environment. A little amount of nanoclay can alter the entire properties of polymers, paints, inks and ...

  2. TMX-U neutral pressure measurement diagnostic systems

    International Nuclear Information System (INIS)

    Pickles, W.L.; Allen, S.L.; Hill, D.N.; Hunt, A.L.; Simonen, T.C.

    1984-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Baird Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflus, getter pumping, and plasma pumping

  3. Analytical characterization of the palette and painting techniques of Jorge Afonso, the great 16th century Master of Lisbon painting workshop

    Science.gov (United States)

    Antunes, Vanessa; Candeias, António; Mirão, José; Carvalho, Maria L.; Dias, Cristina Barrocas; Manhita, Ana; Cardoso, Ana; Francisco, Maria J.; Lauw, Alexandra; Manso, Marta

    2018-03-01

    In this work, a study on a set of paintings from the most significant altarpiece assigned to Master Jorge Afonso (c. 1470-1540) painting workshop is presented. This altarpiece is composed by fourteen paintings made to the church of Convento de Jesus, in Setúbal, Portugal, and was made circa 1517-19/1530, according to art-history. This set of paintings is compared to one of the other most important Portuguese altarpieces from the 16th century: the panels of the Round Church of the Convento de Cristo, in Tomar, made circa 1510-1515. The aim of this study is to characterize the wooden support, pigments, ground layers materials and technique used in Jorge Afonso workshop by means of complementary analyses. A dendrochronological approach was made in order to corroborate (or not) the historical date initially assigned. Infrared photography (IRP) and reflectography (IRR) allowed the study of the underdrawing technique and macro photography (MP) was used to recognize overlapping layers technique. Cross-sections from the paintings were examined by optical microscopy (OM), and analyzed by μ-X-ray diffraction (μ-XRD), Energy Dispersive X-ray Fluorescence spectroscopy (EDXRF), Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy (SEM-EDS), micro-Raman spectroscopy (μ-Raman), micro-Fourier Transform Infrared spectroscopy (μ-FTIR), Pyrolysis Gas Chromatography Mass Spectrometry (py-GC/MS). The characterization of the palette and ground layers and the study of the overlapping of paint layers brought a new insight of the adopted painting techniques by the most important group of painters working in Portugal in the 16th century - the Lisbon workshop, leaded by Master Jorge Afonso.

  4. Pirani pressure sensor with distributed temperature measurement

    NARCIS (Netherlands)

    de Jong, B.R.; Bula, W.P.; Zalewski, D.R.; van Baar, J.J.J.; Wiegerink, Remco J.

    2003-01-01

    Surface micro-machined distributed Pirani pressure gauges, with designed heater-to-heat sink distances (gap-heights) of 0.35 μm and 1.10 μm, are successfully fabricated, modeled and characterized. Measurements and model response correspond within 5% of the measured value in a pressure range of 10 to

  5. Salt sensitivity of blood pressure is associated with polymorphisms in the sodium-bicarbonate cotransporter.

    Science.gov (United States)

    Carey, Robert M; Schoeffel, Cynthia D; Gildea, John J; Jones, John E; McGrath, Helen E; Gordon, Lindsay N; Park, Min Jeong; Sobota, Rafal S; Underwood, Patricia C; Williams, Jonathan; Sun, Bei; Raby, Benjamin; Lasky-Su, Jessica; Hopkins, Paul N; Adler, Gail K; Williams, Scott M; Jose, Pedro A; Felder, Robin A

    2012-11-01

    Previous studies have demonstrated that single nucleotide polymorphisms (SNPs) of the sodium-bicarbonate co-transporter gene (SLC4A5) are associated with hypertension. We tested the hypothesis that SNPs in SLC4A5 are associated with salt sensitivity of blood pressure in 185 whites consuming an isocaloric constant diet with a randomized order of 7 days of low Na(+) (10 mmol/d) and 7 days of high Na(+) (300 mmol/d) intake. Salt sensitivity was defined as a ≥ 7-mm Hg increase in mean arterial pressure during a randomized transition between high and low Na(+) diet. A total of 35 polymorphisms in 17 candidate genes were assayed, 25 of which were tested for association. Association analyses with salt sensitivity revealed 3 variants that associated with salt sensitivity, 2 in SLC4A5 (P<0.001) and 1 in GRK4 (P=0.020). Of these, 2 SNPs in SLC4A5 (rs7571842 and rs10177833) demonstrated highly significant results and large effects sizes, using logistic regression. These 2 SNPs had P values of 1.0 × 10(-4) and 3.1 × 10(-4) with odds ratios of 0.221 and 0.221 in unadjusted regression models, respectively, with the G allele at both sites conferring protection. These SNPs remained significant after adjusting for body mass index and age (P=8.9 × 10(-5) and 2.6 × 10(-4) and odds ratios 0.210 and 0.286, respectively). Furthermore, the association of these SNPs with salt sensitivity was replicated in a second hypertensive population. Meta-analysis demonstrated significant associations of both SNPs with salt sensitivity (rs7571842 [P=1.2 × 10(-5)]; rs1017783 [P=1.1 × 10(-4)]). In conclusion, SLC4A5 variants are strongly associated with salt sensitivity of blood pressure in 2 separate white populations.

  6. Development of Recycling Compatible Pressure-Sensitive Adhesives and Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Steven J. Severtson

    2010-02-15

    The objective of this project was the design of new water-based pressure-sensitive adhesive (PSA) products and coatings engineered for enhanced removal during the processing of recycled fiber. Research included the formulation, characterization, and performance measurements of new screenable coatings, testing of modified paper and board substrates and the design of test methods to characterize the inhibition of adhesive and coating fragmentation and relative removal efficiencies of developed formulations. This project was operated under the requirements that included commercially viable approaches be the focus, that findings be published in the open literature and that new strategies could not require changes in the methods and equipment used to produce PSA and PS labels or in the recycling process. The industrial partners benefited through the building of expertise in their company that they would not, and likely could not, have pursued if it had not been for the partnership. Results of research on water-based PSAs clearly identifies which PSA and paper facestock properties govern the fragmentation of the adhesive and provide multiple strategies for making (pressure-sensitive) PS labels for which the PSA is removed at very high efficiencies from recycling operations. The application of these results has led to the identification of several commercial products in Franklin International’s (industrial partner) product line that are recycling compatible. Several new formulations were also designed and are currently being scaled-up. Work on recycling compatible barrier coatings for corrugated containers examined the reinforcement of coatings using a small amount of exfoliated organically modified montmorillonite (OMMT). These OMMT/paraffin wax nanocomposites demonstrated significantly improved mechanical properties. Paraffin waxes containing clay were found to have significantly higher Young’s moduli and yield stress relative to the wax matrix, but the most

  7. Association between Pressure Pain Sensitivity, Performance stability and Overall Performance in Olympic Sailors

    DEFF Research Database (Denmark)

    Ballegaard, Søren; Petersen, Pernille Bjørn; Harboe, Gitte Sommer

    2016-01-01

    Background: During sports competitions, the performance of athletes may be negatively affected by persistent stress and autonomic nervous system (ANS) dysfunction, both of which can be assessed by pressure pain sensitivity (PPS) at the chest bone. Objectives: To test the association between PPS...... guide for persistent stress and ANS dysfunction. Performance stability, overall performance and PPS measure were assessed at three intervals. Results: At baseline, the median PPS was 83, the performance stability was inferior to the mean top 10 competitors, and the overall performance was rank eight......: r > 0.70; p stress and ANS dysfunction as assessed by PPS on one side and performance stability and overall performance on the other side....

  8. Marine atmospheres provide a tough test for protective paint systems

    Energy Technology Data Exchange (ETDEWEB)

    Steptoe, G.G.C.

    1980-04-01

    Protective paints based on chlorinated rubber (CR) offer good resistance to salt-laden atmospheres and extreme climatic conditions, possess low moisture and oxygen permeability, and are resistant to a variety of chemicals, which allows them to counter the acidic and alkaline conditions tha arise from the corrosion of steel in salt water and from cathodic protection. Airless spray techniques allow CR paints to be applied much faster in thick coatings to large surface areas. CR paints can be formulated to produce a dry film thickness of 80-100 jm in one application. One study concluded that the extra expense for good surface preparation and high-performance paint can be regained in 2-4 yr as a result of lower maintenance costs. CR paints can be used successfully with cathodic protection; however, their tolerance to overprotection is less than that of some alternative systems; CR paints are considered to be suitable for use up to a maximum of -0.95 v. The numerous applications of CR paint include large crude carriers, offshore oil structures, oil terminals (e.g., the Flotta terminal in the Orkneys), and storage tanks.

  9. Zhang Qing and His Meticulous Chinese Paintings

    Institute of Scientific and Technical Information of China (English)

    JULIE; M.SEGRAVES

    2002-01-01

    ZHANG Qing was initially drawn to the bird and flower paint-ings of the Tang and Song dynasties (7th-12th centuries). Later,Qing Dynasty (1644-1911) artist Ren Bonian, famous for hispaintings of figures, also became an important influence.Although Zhang Qing considers his style to be firmly rooted in tradi-

  10. Highly transparent poly(2-ethyl-2-oxazoline)-TiO2 nanocomposite coatings for the conservation of matte painted artworks

    OpenAIRE

    Colombo, A.; Gherardi, Francesca; Goidanich, S.; Delaney, J. K.; de la Rie, E. R.; Ubaldi, M. C.; Toniolo, L.; Simonutti, R.

    2015-01-01

    A nanocomposite coating based on TiO2 nanoparticles and poly(2-ethyl-2-oxazoline) is used as consolidant of matte painted surfaces (temperas, watercolors, modern paintings). The aim of this work is to provide advances in the conservation of these works of art, while preserving their optical appearance, in terms of colour and gloss. Fiber Optic Reflectance Spectroscopy (FORS) measurements of a painting-model (an acrylic black monochrome) treated with the nanocomposite coatings revealed that it...

  11. Using pressure square-like wave to measure the dynamic characteristics of piezoelectric pressure sensor

    International Nuclear Information System (INIS)

    Han, L-L; Tsung, T-T; Chen, L-C; Chang Ho; Jwo, C-S

    2005-01-01

    Piezoelectric pressure sensors are commonly used to measuring the dynamic characteristics in a hydraulic system. The dynamic measurements require a pressure sensor which has a high response rate. In this paper, we proposed use of a pressure square wave to excite the piezoelectric pressure sensor. Experimental frequencies are 0.5, 1.0, 1.5, and 2.0 kHz at 10, 15, 20 bar, respectively. Results show that the waveform of time-domain and frequencydomain response are quite different under above testing conditions. The higher the frequencies tested, the faster the pressure-rise speeds obtained. Similarly, the higher the testing pressure, the shorter the rise time attained

  12. Mediterranean diet and insulin sensitivity, lipid profile and blood pressure levels, in overweight and obese people; The Attica study

    Directory of Open Access Journals (Sweden)

    Zampelas Antonis

    2007-09-01

    Full Text Available Abstract Background We aimed to investigate if overweight and obese adults "close" to Mediterranean diet present better insulin, lipids profile and better pressure levels, compared to individuals close to a more Westernized diet. Methods The ATTICA study is a population-based cohort that has randomly enrolled 3042 adult men and women, stratified by age – gender, from the greater area of Athens, during 2001–2002. Of them, in this work were have studied 1762 participants with excess body weight, meaning overweight (BMI: 25–29.9 kg/m2 and obese (BMI>30 kg/m2. 1064 were men and 698 women (20–89 years old. Adherence to Mediterranean diet was assessed through a diet-score that was based on a validated food-frequency questionnaire. Blood pressure was measured and also fasting glucose, insulin and blood lipids. Insulin sensitivity was also assessed by the homeostasis model assessment (HOMA approach (glucose × insulin/22.5. Results Individuals with excess bodyweight in the highest tertile of diet score, were more insulin sensitive than those in the lowest tertile (11.4% lower HOMA, p = 0.06, had 13% lower levels of total cholesterol (p = 0.001 and 3 mmHg decrease of systolic blood pressure levels (p Conclusion Adherence to Mediterranean diet is modeslty associated with a better insulin sensitivity, lower levels of total cholesterol and lower levels of systolic blood pressure in overweight and obese subjects. This may suggest that compared to general population, the beneficial effect of this diet in cardiovascular system of excess body weight people is limited.

  13. Full scale measurement of wind induced pressures : 1 configuration of wind induced pressures

    NARCIS (Netherlands)

    Geurts, C.P.W.; Wijen, H.L.M.

    1994-01-01

    A research project 10 the spectral characteristics of wind induced pressures is in progress in Eindhoven. This project includes both wind tunnel and full scale measurements. Wind induced pressures are measured in full scale at the main building of Eindhoven University of Technology. This paper

  14. Micro transflection on a metallic stick: an innovative approach of reflection infrared spectroscopy for minimally invasive investigation of painting varnishes.

    Science.gov (United States)

    Rosi, Francesca; Legan, Lea; Miliani, Costanza; Ropret, Polonca

    2017-05-01

    A new analytical approach, based on micro-transflection measurements from a diamond-coated metal sampling stick, is presented for the analysis of painting varnishes. Minimally invasive sampling is performed from the varnished surface using the stick, which is directly used as a transflection substrate for micro Fourier transform infrared (FTIR) measurements. With use of a series of varnished model paints, the micro-transflection method has been proved to be a valuable tool for the identification of surface components thanks to the selectivity of the sampling, the enhancement of the absorbance signal, and the easier spectral interpretation because the profiles are similar to transmission mode ones. Driven by these positive outcomes, the method was then tested as tool supporting noninvasive reflection FTIR spectroscopy during the assessment of varnish removal by solvent cleaning on paint models. Finally, the integrated analytical approach based on the two reflection methods was successfully applied for the monitoring of the cleaning of the sixteenth century painting Presentation in the Temple by Vittore Carpaccio. Graphical Abstract Micro-transflection FTIR on a metallic stick for the identification of varnishes during painting cleanings.

  15. Thermal characterization of intumescent fire retardant paints

    International Nuclear Information System (INIS)

    Calabrese, L; Bozzoli, F; Rainieri, S; Pagliarini, G; Bochicchio, G; Tessadri, B

    2014-01-01

    Intumescent coatings are now the dominant passive fire protection materials used in industrial and commercial buildings. The coatings, which usually are composed of inorganic components contained in a polymer matrix, are inert at low temperatures and at higher temperatures, they expand and degrade to provide a charred layer of low conductivity materials. The charred layer, which acts as thermal barrier, will prevent heat transfer to underlying substrate. The thermal properties of intumescent paints are often unknown and difficult to be estimated since they vary significantly during the expansion process; for this reason the fire resistance validation of a commercial coatings is based on expensive, large-scale methods where each commercial coating-beam configuration has to be tested one by one. Adopting, instead, approaches based on a thermal modelling of the intumescent paint coating could provide an helpful tool to make easier the test procedure and to support the design of fire resistant structures as well. The present investigation is focused on the assessment of a methodology intended to the restoration of the equivalent thermal conductivity of the intumescent layer produced under the action of a cone calorimetric apparatus. The estimation procedure is based on the inverse heat conduction problem approach, where the temperature values measured at some locations inside the layer during the expansion process are used as input known data. The results point out that the equivalent thermal conductivity reached by the intumescent material at the end of the expansion process significantly depends on the temperature while the initial thickness of the paint does not seem to have much effect

  16. Thermal characterization of intumescent fire retardant paints

    Science.gov (United States)

    Calabrese, L.; Bozzoli, F.; Bochicchio, G.; Tessadri, B.; Rainieri, S.; Pagliarini, G.

    2014-11-01

    Intumescent coatings are now the dominant passive fire protection materials used in industrial and commercial buildings. The coatings, which usually are composed of inorganic components contained in a polymer matrix, are inert at low temperatures and at higher temperatures, they expand and degrade to provide a charred layer of low conductivity materials. The charred layer, which acts as thermal barrier, will prevent heat transfer to underlying substrate. The thermal properties of intumescent paints are often unknown and difficult to be estimated since they vary significantly during the expansion process; for this reason the fire resistance validation of a commercial coatings is based on expensive, large-scale methods where each commercial coating-beam configuration has to be tested one by one. Adopting, instead, approaches based on a thermal modelling of the intumescent paint coating could provide an helpful tool to make easier the test procedure and to support the design of fire resistant structures as well. The present investigation is focused on the assessment of a methodology intended to the restoration of the equivalent thermal conductivity of the intumescent layer produced under the action of a cone calorimetric apparatus. The estimation procedure is based on the inverse heat conduction problem approach, where the temperature values measured at some locations inside the layer during the expansion process are used as input known data. The results point out that the equivalent thermal conductivity reached by the intumescent material at the end of the expansion process significantly depends on the temperature while the initial thickness of the paint does not seem to have much effect.

  17. Fabrication and calibration of a piezoelectric nanocomposite paint

    Science.gov (United States)

    Osho, Samuel; Wu, Nan; Aramfard, Mohammad; Deng, Chuang; Ojo, Olanrewaju

    2018-03-01

    A new liquid form piezoelectric nanocomposite paint material is fabricated with possible applications as dynamic strain sensors and/or piezoelectric transducers. The applied coating is in the form of low-cost paint, which is flexible and bonds strongly on a metallic surface after drying out via the solvent-casting method. The nanocomposite is produced by an ultrasonic mixture of varying percentages of zinc oxide (ZnO) nanoparticle water dispersion, poly vinyl acetate glue (PVA) and carbon nanotubes (CNTs). ZnO nanoparticles are used as the piezoelectric sensing elements in a PVA matrix of the paint, while CNTs are introduced as robust bridge of ZnO particles enhancing the piezoelectricity and material properties. Transmission electron microscopy (TEM) images confirmed the linkages of ZnO nanoparticles in the composite by CNTs. Through piezoelectricity calibration, the optimum mixing ratio with the highest piezoelectricity is 78.1 wt% ZnO, 19.5 wt% PVA glue and 2.4 wt% multi-wall carbon nanotubes (MWCNTs). Through nanoindentation tests for the characterization of the mechanical properties of the nano-composite paint, it is found that Young’s modulus and hardness reached a threshold point in the increment in the addition of CNTs to the paint before showing signs of decline. Detailed analysis and explanation of the calibration results and physical phenomenon are provided. The stable paint material is ready to be applied on rough area of engineering structures as sensor and transducer.

  18. Measuring sensitivity in pharmacoeconomic studies. Refining point sensitivity and range sensitivity by incorporating probability distributions.

    Science.gov (United States)

    Nuijten, M J

    1999-07-01

    The aim of the present study is to describe a refinement of a previously presented method, based on the concept of point sensitivity, to deal with uncertainty in economic studies. The original method was refined by the incorporation of probability distributions which allow a more accurate assessment of the level of uncertainty in the model. In addition, a bootstrap method was used to create a probability distribution for a fixed input variable based on a limited number of data points. The original method was limited in that the sensitivity measurement was based on a uniform distribution of the variables and that the overall sensitivity measure was based on a subjectively chosen range which excludes the impact of values outside the range on the overall sensitivity. The concepts of the refined method were illustrated using a Markov model of depression. The application of the refined method substantially changed the ranking of the most sensitive variables compared with the original method. The response rate became the most sensitive variable instead of the 'per diem' for hospitalisation. The refinement of the original method yields sensitivity outcomes, which greater reflect the real uncertainty in economic studies.

  19. Special duties of paints in nuclear environment in India with examples of application

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Subbaratnam, T.

    1978-01-01

    Any process involving nuclear interactions gives rise to radioactivity and radiation in various degrees apart from conventional effects like heat, pressure, etc. Vessels and structures containing such processes are subject to various degrees of radioactivity and contamination by liquid, gaseous or particulate radioactive materials coming in contact with the substrate. Thus, in any nuclear environment surfaces require protection against both radioactive contamination and normal corrosion forces. The protective coating should be able to resist the radiation field in which it is placed and also withstand decontamination process for removal of radioactive contamination from the surface as and when required. Radioactive contamination due to any radiochemical operation is objectionable for two reasons: (i) it constitutes a potential radiation hazard to occupants of the facility, and (ii) cross contamination jeoparadizes the validity of the experimental data. The difficulty experienced in decontaminating many materials used in construction of such nuclear or radiochemical facilities has therefore given emphasis to the search for suitable coating matetials. This paper deals with the two special duties expected of paints in such environment, viz., radiation resistance and decontaminability tests in this regard in BARC and examples of actual selections and applications in an Indian nuclear power station. Some areas requiring investigations and serious attention for industrial painting in general and nuclear painting work in particular have been also identified. (author)

  20. The bay of Cattaro (Kotor school of icon-painting 1680-1860

    Directory of Open Access Journals (Sweden)

    Stošić Ljiljana

    2014-01-01

    Full Text Available Relying on post-Byzantine tradition, eleven painters from five generations of the Dimitrijević-Rafailović family, accompanied by Maksim Tujković, painted several thousand icons and several hundred iconostases between the late seventeenth and the second half of the nineteenth century. They worked in major Orthodox Christian monasteries in Montenegro, Kosovo and Metohija, Bosnia and Herzegovina and Dalmatia, but their works can mostly be found in modest village churches in the Bay of Kotor (Cattaro and on the South Adriatic coast. The decoration of these churches was financially supported by the local population headed by elders. Along with a reconstruction of their biographies and a chronological overview of their major works, this paper seeks to trace stylistic changes in the Bay of Kotor school of icon-painting. While simply varying a thematic repertory established in earlier periods, the painters from the Bay of Kotor were gradually introducing new details and themes adopted from Western European Baroque art under indirect influences coming from the monastery of Hilandar, Corfu, Venice and Russia. This process makes this indigenous school of icon-painting, which spanned almost two centuries, comparable to the work of Serbian traditional religious painters (zografs and illuminators active north of the Sava and Danube rivers after the Great Migration of the Serbs (1690. Despite differences between the two, which resulted from different cultural and historical circumstances in which Serbs lived under Ottoman, Venetian and Habsburg rules, similarities in iconography and style, which were inspired by an urge to counteract proselytic pressures, are considerably more important.

  1. Sensitizing effects of NOx on CH4 oxidation at high pressure

    DEFF Research Database (Denmark)

    Rasmussen, Christian Lund; Rasmussen, Anja Egede; Glarborg, Peter

    2008-01-01

    The CH4/O2/NOx system is investigated in a laboratory-scale high pressure laminar flow reactor with the purpose of elucidating the sensitizing effects of NOx on CH4 oxidation at high pressures and medium temperatures. Experiments are conducted at 100, 50, and 20 bar, 600-900 K, and stoichiometric...... ratios ranging from highly reducing to oxidizing conditions. The experimental results are interpreted in terms of a detailed kinetic model drawn from previous work of the authors, including an updated reaction subset for the direct interactions of NOx and C1-2 hydrocarbon species relevant...

  2. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  3. Studies on some Indian paints for radiochemical plants

    International Nuclear Information System (INIS)

    Mahesh Kumar, V.V.; Srinivasan, R.; Natarajan, R.

    1996-01-01

    The choice of paints in areas subjected to contamination and radiation in nuclear installation need special attention. The types of generic coatings are examined with reference to these requirements. Among those examined, certain types of epoxy paints are found to be attractive for these applications. Samples of epoxy paints obtained from some Indian manufacturers are tested for their suitability. Decontaminability and radiation resistance properties are also evaluated with special reference to radiochemical plants. Important specifications for such applications are listed. This report summarizes the results of these studies. (author)

  4. Automatic forensic analysis of automotive paints using optical microscopy.

    Science.gov (United States)

    Thoonen, Guy; Nys, Bart; Vander Haeghen, Yves; De Roy, Gilbert; Scheunders, Paul

    2016-02-01

    The timely identification of vehicles involved in an accident, such as a hit-and-run situation, bears great importance in forensics. To this end, procedures have been defined for analyzing car paint samples that combine techniques such as visual analysis and Fourier transform infrared spectroscopy. This work proposes a new methodology in order to automate the visual analysis using image retrieval. Specifically, color and texture information is extracted from a microscopic image of a recovered paint sample, and this information is then compared with the same features for a database of paint types, resulting in a shortlist of candidate paints. In order to demonstrate the operation of the methodology, a test database has been set up and two retrieval experiments have been performed. The first experiment quantifies the performance of the procedure for retrieving exact matches, while the second experiment emulates the real-life situation of paint samples that experience changes in color and texture over time. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Optical fiber pressure sensor based on fiber Bragg grating

    Science.gov (United States)

    Song, Dongcao

    In oil field, it is important to measure the high pressure and temperature for down-hole oil exploration and well-logging, the available traditional electronic sensor is challenged due to the harsh, flammable environment. Recently, applications based on fiber Bragg grating (FBG) sensor in the oil industry have become a popular research because of its distinguishing advantages such as electrically passive operation, immunity to electromagnetic interference, high resolution, insensitivity to optical power fluctuation etc. This thesis is divided into two main sections. In the first section, the design of high pressure sensor based on FBG is described. Several sensing elements based on FBG for high pressure measurements have been proposed, for example bulk-modulus or free elastic modulus. But the structure of bulk-modulus and free elastic modulus is relatively complex and not easy to fabricate. In addition, the pressure sensitivity is not high and the repeatability of the structure has not been investigated. In this thesis, a novel host material of carbon fiber laminated composite (CFLC) for high pressure sensing is proposed. The mechanical characteristics including principal moduli in three directions and the shape repeatability are investigated. Because of it's Young's modulus in one direction and anisotropic characteristics, the pressure sensor made by CFLC has excellent sensitivity. This said structure can be used in very high pressure measurement due to carbon fiber composite's excellent shape repetition even under high pressure. The experimental results show high pressure sensitivity of 0.101nm/MPa and high pressure measurement up to 70MPa. A pressure sensor based on CFLC and FBG with temperature compensation has been designed. In the second section, the design of low pressure sensor based on FBG is demonstrated. Due to the trade off between measurement range and sensitivity, a sensor for lower pressure range needs more sensitivity. A novel material of carbon

  6. Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of Protein-Stabilized Gold Nanoclusters

    Science.gov (United States)

    2016-01-01

    ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure ...ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of...DATES COVERED (From - To) May 2014–September 2014 4. TITLE AND SUBTITLE Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure

  7. Can painted glass felt or glass fibre cloth be used as vapour barrier?

    DEFF Research Database (Denmark)

    El-Khattam, Amira; Andersen, Mie Them; Hansen, Kurt Kielsgaard

    2014-01-01

    In most Nordic homes the interior surfaces of walls and ceilings have some kind of surface treatment for aesthetical reasons. The treatments can for example be glass felt or glass fibre cloth which are painted afterwards. To evaluate the hygrothermal performance of walls and ceilings...... treatments. The surface treatments were glass felt or glass fibre cloth with different types of paints or just paint. The paint types were acrylic paint and silicate paint. The results show that the paint type has high influence on the water vapour resistance while the underlay i.e. glass felt or glass fibre...... acrylic paint on glass felt or glass fibre cloth cannot be used instead of a vapour barrier....

  8. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  9. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  10. Library Signage: Applications for the Apple Macintosh and MacPaint.

    Science.gov (United States)

    Diskin, Jill A.; FitzGerald, Patricia

    1984-01-01

    Describes specific applications of the Macintosh computer at Carnegie-Mellon University Libraries, where MacPaint was used as a flexible, easy to use, and powerful tool to produce informational, instructional, and promotional signage. Profiles of system hardware and software, an evaluation of the computer program MacPaint, and MacPaint signage…

  11. Elemental composition of paint cross sections by nuclear microprobe analysis

    International Nuclear Information System (INIS)

    Nens, B.; Trocellier, P.; Engelmann, C.; Lahanier, C.

    1982-09-01

    Physico-chemical characterization of pigments used in artistic painting give precious indications on age of paintings and sometimes on geographical origin of ores. After recalling the principle of protons microprobe, first results obtained by microanalysis of painting cross sections for non destructive microanalysis of impurities in white lead are given [fr

  12. Factors effecting paint performance on wood siding

    Science.gov (United States)

    Christopher G. Hunt; R. Sam Williams; Mark Knaebe; Peter Sotos; Steven Lacher

    2009-01-01

    Several different studies are compared to assess the effectiveness of commercial water repellent preservatives (WRP’s) in the late 1990’s on vertical and horizontal siding. Besides WRP, variables included wood species, exposure location (Wisconsin or Mississippi), and solid color stain vs. primer + paint. Data on substrate checking and paint flaking are presented....

  13. The Sign System in Chinese Landscape Paintings

    Science.gov (United States)

    McMahon, Cliff G.

    2003-01-01

    Paintings emerge from a culture field and must be interpreted in relation to the net of culture. A given culture will be implicated by the sign system used by the painter. Everyone agrees that in Chinese landscape paintings, the most important cultural bond is to ancient Chinese Taoism, and to a lesser degree, to Confucianism. Obviously, then, the…

  14. Building a fingerprint database for modern art materials: PIXE analysis of commercial painting and drawing media

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Climent-Font, A. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Departamento de Física Aplicada, Universidad Autónoma de Madrid, Avda. Francisco Tomás y Valiente 7, 28049 Madrid (Spain); Gómez-Tejedor, J. García [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain); Martina, S. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Universitá degli Studi di Torino, Turin (Italy); Muro García, C.; Gimeno, E.; Hernández, P.; Canelo, N. [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain)

    2015-11-15

    We have examined by PIXE (and by RBS in parallel) about 180 samples of commercial painting and drawing media including pencils, pastels, waxes, inks, paints and paper. Given the high PIXE sensitivity we produced X-ray spectra at low collected charges and currents, operating in good conservation conditions. For drawing media containing inorganic components or a unique marker element, we have defined colouring agent fingerprints which correspond, when applicable, to the composition declared by the manufacturer. For thin layers, the ratios of areal densities of elements are close to those expected given the declared composition, which is promising from the perspective of compiling the database. The quantitative PIXE and RBS analysis of part of the set of samples is provided.

  15. Atomic Oxygen Treatment Technique for Removal of Smoke Damage from Paintings

    Science.gov (United States)

    Rutledge, S. K.; Banks, B. A.

    1997-01-01

    Soot deposits that can accumulate on surfaces of a painting during a fire can be difficult to clean from some types of paintings without damaging the underlying paint layers. A non-contact technique has been developed which can remove the soot by allowing a gas containing atomic oxygen to flow over the surface and chemically react with the soot to form carbon monoxide and carbon dioxide. The reaction is limited to the surface, so the underlying paint is not touched. The process can be controlled so that the cleaning can be stopped once the paint surface is reached. This paper describes the smoke exposure and cleaning of untreated canvas, acrylic gesso, and sections of an oil painting using this technique. The samples were characterized by optical microscopy and reflectance spectroscopy.

  16. A New Quantitative Method for the Non-Invasive Documentation of Morphological Damage in Paintings Using RTI Surface Normals

    Directory of Open Access Journals (Sweden)

    Marcello Manfredi

    2014-07-01

    Full Text Available In this paper we propose a reliable surface imaging method for the non-invasive detection of morphological changes in paintings. Usually, the evaluation and quantification of changes and defects results mostly from an optical and subjective assessment, through the comparison of the previous and subsequent state of conservation and by means of condition reports. Using quantitative Reflectance Transformation Imaging (RTI we obtain detailed information on the geometry and morphology of the painting surface with a fast, precise and non-invasive method. Accurate and quantitative measurements of deterioration were acquired after the painting experienced artificial damage. Morphological changes were documented using normal vector images while the intensity map succeeded in highlighting, quantifying and describing the physical changes. We estimate that the technique can detect a morphological damage slightly smaller than 0.3 mm, which would be difficult to detect with the eye, considering the painting size. This non-invasive tool could be very useful, for example, to examine paintings and artwork before they travel on loan or during a restoration. The method lends itself to automated analysis of large images and datasets. Quantitative RTI thus eases the transition of extending human vision into the realm of measuring change over time.

  17. Simultaneous measurement of temperature and pressure by a single fiber Bragg grating with a broadened reflection spectrum.

    Science.gov (United States)

    Guo, Tuan; Qiao, Xueguang; Jia, Zhenan; Zhao, Qida; Dong, Xiaoyi

    2006-05-01

    Simultaneous measurement of temperature and pressure with a single fiber Bragg grating (FBG) based on a broadened reflection spectrum is proposed and experimentally demonstrated. A novel double-hole structure of a cantilever beam is designed, and a FBG is affixed on the nonuniform strain area of the cantilever beam. The Bragg reflection bandwidth is sensitive to the spatially gradient strain but is free from the spatially uniform temperature. The wavelength peak shift and the bandwidth broadening of the FBG with a change of temperature and pressure allow for simultaneous discrimination between the temperature and the pressure effects. Standard deviation errors of 1.4 degrees C and 1.8 kPa were obtained with temperature and pressure ranges of 20 degrees C-100 degrees C and 0-80 kPa, respectively. This novel and low-cost sensor approach has considerable potential applications for temperature-insensitive strain measurement.

  18. Sensitivity and specificity of hypopnoea detection using nasal pressure in the presence of a nasal expiratory resistive device (Provent®)

    International Nuclear Information System (INIS)

    Milne, Stephen; Amis, Terence C; Wheatley, John R; Kairaitis, Kristina

    2014-01-01

    Nasal expiratory resistive valves (Provent ® ) have been proposed as novel therapy for obstructive sleep apnea. We compared pressure measurements from a standard nasal pressure catheter used to assess nasal airflow during sleep with those from nasal expiratory resistive device with attached proprietary nasal pressure cannula. Nasal pressure cannula or Provent ® + proprietary nasal pressure cannula were attached to a bench model of human anterior nares and nasal passages, and pressure measured (P). Respiratory airflows generated by a subject breathing were applied to rear of model and airflow ( V-dot ) measured via pneumotachograph. Airflow amplitude (Δ V-dot ) was plotted against pressure amplitude (ΔP). Hypopnoea detection (<50% Δ V-dot ) sensitivity and specificity was tested by expressing ΔP in terms of two reference breaths: reference breath 1, Δ V-dot 0.55 L s −1  = 100%; and reference breath 2, Δ V-dot 0.45 L s −1  = 100%. ΔP/Δ V-dot relationships were linear for Δ V-dot  ≤ 0.55 L s −1 ; ΔP = 0.37ΔV + 0.16 (nasal pressure cannula), ΔP = 2.7ΔV + 0.12 (Provent ® + proprietary nasal pressure cannula); both R 2  > 0.65, p < 0.0001; p < 0.0001 for between slope difference). For nasal pressure cannula, specificity of hypopnoea detection differed between reference breaths one and two (80.2% and 40.0%, respectively), and Provent ® + proprietary nasal pressure cannula (30.3% and 74.2%, respectively). Quantification of airflow obstruction in the presence of Provent ® + proprietary nasal pressure cannula is greatly influenced by the reference breath chosen to determine a reduction in nasal airflow. Reported variability in therapeutic response to nasal expiratory resistive devices may relate to differences in measurement technique specificity used to quantify the severity of sleep disordered breathing. (paper)

  19. High pressure measurement of the uniaxial stress of host layers on intercalants and staging transformation of intercalation compounds

    CERN Document Server

    Park, T R; Kim, H; Min, P

    2002-01-01

    A layered double-hydroxide intercalation compound was synthesized to measure the uniaxial stress the host layers exert on the intercalants. To measure the uniaxial stress, we employed the photoluminescence (PL) from the intercalated species, the Sm ion complex, as it is sensitive to the deformation of the intercalants. Of the many PL peaks the Sm ion complex produces, the one that is independent of the counter-cation environment was chosen for the measurement since the Sm ion complexes are placed under a different electrostatic environment after intercalation. The peak position of the PL was redshifted linearly with increasing hydrostatic pressure on the intercalated sample. Using this pressure-induced redshifting rate and the PL difference at ambient pressure between the pre-intercalation and the intercalated ions, we found that, in the absence of external pressure, the uniaxial stress exerted on the samarium ion complexes by the host layers was about 13.9 GPa at room temperature. Time-resolved PL data also ...

  20. Development of high sensitivity eight-element multiplexed fiber laser acoustic pressure hydrophone array and interrogation system

    Science.gov (United States)

    Li, Ming; Sun, Zhihui; Zhang, Xiaolei; Li, Shujuan; Song, Zhiqiang; Wang, Meng; Guo, Jian; Ni, Jiasheng; Wang, Chang; Peng, Gangding; Xu, Xiangang

    2017-09-01

    Fiber laser hydrophones have got widespread concerns due to the unique advantages and broad application prospects. In this paper, the research results of the eight-element multiplexed fiber laser acoustic pressure array and the interrogation system are introduced, containing low-noise distributed feedback fiber laser (DFB-FL) fabrication, sensitivity enhancement packaging, and interferometric signal demodulation. The frequency response range of the system is 10Hz-10kHz, the laser frequency acoustic pressure sensitivity reaches 115 dB re Hz/Pa, and the equivalent noise acoustic pressure is less than 60μPa/Hz1/2. The dynamic range of the system is greater than 120 dB.