WorldWideScience

Sample records for preparation computer repair

  1. 3D artificial bones for bone repair prepared by computed tomography-guided fused deposition modeling for bone repair.

    Science.gov (United States)

    Xu, Ning; Ye, Xiaojian; Wei, Daixu; Zhong, Jian; Chen, Yuyun; Xu, Guohua; He, Dannong

    2014-09-10

    The medical community has expressed significant interest in the development of new types of artificial bones that mimic natural bones. In this study, computed tomography (CT)-guided fused deposition modeling (FDM) was employed to fabricate polycaprolactone (PCL)/hydroxyapatite (HA) and PCL 3D artificial bones to mimic natural goat femurs. The in vitro mechanical properties, in vitro cell biocompatibility, and in vivo performance of the artificial bones in a long load-bearing goat femur bone segmental defect model were studied. All of the results indicate that CT-guided FDM is a simple, convenient, relatively low-cost method that is suitable for fabricating natural bonelike artificial bones. Moreover, PCL/HA 3D artificial bones prepared by CT-guided FDM have more close mechanics to natural bone, good in vitro cell biocompatibility, biodegradation ability, and appropriate in vivo new bone formation ability. Therefore, PCL/HA 3D artificial bones could be potentially be of use in the treatment of patients with clinical bone defects.

  2. Specification guidelines for surface preparation of concrete prior to repair

    OpenAIRE

    Courard, Luc; Bissonnette, Benoît; Garbacz, Andrzej

    2017-01-01

    The repair of concrete requests specific preparation operations needed for guaranteeing compatibility between substrate and new materials as well as the development of adhesion properties. These specification guidelines contain design and construction recommendations for surface preparation of concrete for repair and overlay. The paper summarizes current knowledge, best practices and results of the research concerning the surface preparation of concrete prior to application of repair/overlay ...

  3. Computer Technology for Expediency Consideration of Transformer Switching-Off for Capital Repair

    Directory of Open Access Journals (Sweden)

    E. M. Farkhadzade

    2011-01-01

    Full Text Available The paper considers computer technologies for expediency consideration of worn-out transformer recovery in power systems. Methods for list preparation of transformers to be selected for capital repair, estimation of repair quality, control over execution of contractual obligations are presented in the paper.

  4. Preparing Slide Presentations on Computers.

    Science.gov (United States)

    Elberfeld, John K.

    1982-01-01

    Suggest use of well-organized slide presentation as effective way to introduce computers to large audiences and discusses how to get started--state objective, analyze audience, outline presentation, prepare slides--and equipment needed to obtain slides from television screens, miniature components, and book illustrations. References and sources…

  5. 29 CFR 541.401 - Computer manufacture and repair.

    Science.gov (United States)

    2010-07-01

    ... programming or other similarly skilled computer-related occupations identified in § 541.400(b), are also not... 29 Labor 3 2010-07-01 2010-07-01 false Computer manufacture and repair. 541.401 Section 541.401... DEFINING AND DELIMITING THE EXEMPTIONS FOR EXECUTIVE, ADMINISTRATIVE, PROFESSIONAL, COMPUTER AND...

  6. Practical Skills in Laptop Computer Repairs for Curriculum Innovation in Technical Education Programmes in Nigeria

    Science.gov (United States)

    Chukwuedo, Samson O.; Omofonmwan, Godwin O.

    2015-01-01

    The increase in the use of laptop computer in Nigeria with their corresponding incessant breakdown calls for the preparation of competent technicians/technologists to carry out such repairs at the downtime of the appliance. This is one of the responsibilities of technology education programmes. This study therefore determined the practical skills…

  7. Practical Skills in Laptop Computer Repairs for Curriculum Innovation in Technical Education Programmes in Nigeria

    Science.gov (United States)

    Chukwuedo, Samson O.; Omofonmwan, Godwin O.

    2015-01-01

    The increase in the use of laptop computer in Nigeria with their corresponding incessant breakdown calls for the preparation of competent technicians/technologists to carry out such repairs at the downtime of the appliance. This is one of the responsibilities of technology education programmes. This study therefore determined the practical skills…

  8. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  9. Effect of cavity preparation on the flexural strengths of acrylic resin repairs

    Directory of Open Access Journals (Sweden)

    Safa Salim Elhadiry

    2010-12-01

    Full Text Available OBJECTIVE: To investigate the effect of cavity preparation on the flexural strength of heat-curing denture resin when repaired with an auto-curing resin. MATERIAL AND METHODS: Ninety-six rectangular specimens (64x10x2.5 mm prepared from heat-curing denture base resin (Meliodent were randomly divided into four groups before repair. One group was left intact as control. Each repair specimen was sectioned into two; one group was repaired using the conventional repair method (Group 1. Two groups had an additional transverse cavity (2x3.5x21.5 mm prepared prior to the repair; one repaired with (Group 2 and one without glass-fiber reinforcement (Group 3. A three-point flexural bending test according to the ISO 1567:1999 specification8 for denture base polymers was carried out on all groups after 1, 7 and 30 days of water immersion. Statistical analysis was carried out using two-way ANOVA, Kruskal Wallis and post-hoc Mann Whitney tests. RESULTS: The highest flexural strength was observed in the control group. Control and conventional repairs group (Group 1 showed reduction in the flexural strength 30 days after water immersion. No significant change in the strength was observed for Groups 2 and 3 where the repair joints were similarly prepared with additional transverse cavity. CONCLUSION: Repaired specimens showed lower flexural strength values than intact heat-curing resin. Cavity preparation had no significant effect on the flexural strength of repair with water immersion.

  10. Repair work in the context of English language mediated computer interface use: A conversation analytic study

    DEFF Research Database (Denmark)

    Raudaskoski, Pirkko

    1992-01-01

    The main aim in this study is to develop an understanding of how repair work is managed in the intertwining of activities and actions with talk and language. By doing this, the richness of the concept of repair in interactional studies is shown. The core work concentrates on exploring repair work...... the English language as a resource. The computer interface use context was chosen to show how narrowly traditional research has seen repair work....

  11. Computational modeling of muscular thin films for cardiac repair

    Science.gov (United States)

    Böl, Markus; Reese, Stefanie; Parker, Kevin Kit; Kuhl, Ellen

    2009-03-01

    Motivated by recent success in growing biohybrid material from engineered tissues on synthetic polymer films, we derive a computational simulation tool for muscular thin films in cardiac repair. In this model, the polydimethylsiloxane base layer is simulated in terms of microscopically motivated tetrahedral elements. Their behavior is characterized through a volumetric contribution and a chain contribution that explicitly accounts for the polymeric microstructure of networks of long chain molecules. Neonatal rat ventricular cardiomyocytes cultured on these polymeric films are modeled with actively contracting truss elements located on top of the sheet. The force stretch response of these trusses is motivated by the cardiomyocyte force generated during active contraction as suggested by the filament sliding theory. In contrast to existing phenomenological models, all material parameters of this novel model have a clear biophyisical interpretation. The predictive features of the model will be demonstrated through the simulation of muscular thin films. First, the set of parameters will be fitted for one particular experiment documented in the literature. This parameter set is then used to validate the model for various different experiments. Last, we give an outlook of how the proposed simulation tool could be used to virtually predict the response of multi-layered muscular thin films. These three-dimensional constructs show a tremendous regenerative potential in repair of damaged cardiac tissue. The ability to understand, tune and optimize their structural response is thus of great interest in cardiovascular tissue engineering.

  12. Computational techniques for the assessment of fracture repair.

    Science.gov (United States)

    Anderson, Donald D; Thomas, Thaddeus P; Campos Marin, Ana; Elkins, Jacob M; Lack, William D; Lacroix, Damien

    2014-06-01

    The combination of high-resolution three-dimensional medical imaging, increased computing power, and modern computational methods provide unprecedented capabilities for assessing the repair and healing of fractured bone. Fracture healing is a natural process that restores the mechanical integrity of bone and is greatly influenced by the prevailing mechanical environment. Mechanobiological theories have been proposed to provide greater insight into the relationships between mechanics (stress and strain) and biology. Computational approaches for modelling these relationships have evolved from simple tools to analyze fracture healing at a single point in time to current models that capture complex biological events such as angiogenesis, stochasticity in cellular activities, and cell-phenotype specific activities. The predictive capacity of these models has been established using corroborating physical experiments. For clinical application, mechanobiological models accounting for patient-to-patient variability hold the potential to predict fracture healing and thereby help clinicians to customize treatment. Advanced imaging tools permit patient-specific geometries to be used in such models. Refining the models to study the strain fields within a fracture gap and adapting the models for case-specific simulation may provide more accurate examination of the relationship between strain and fracture healing in actual patients. Medical imaging systems have significantly advanced the capability for less invasive visualization of injured musculoskeletal tissues, but all too often the consideration of these rich datasets has stopped at the level of subjective observation. Computational image analysis methods have not yet been applied to study fracture healing, but two comparable challenges which have been addressed in this general area are the evaluation of fracture severity and of fracture-associated soft tissue injury. CT-based methodologies developed to assess and quantify

  13. Methods for designing building envelope components prepared for repair and maintenance

    DEFF Research Database (Denmark)

    Rudbeck, Claus Christian

    2000-01-01

    to be prepared for repair and maintenance. Both of these components are insulation systems for flat roofs and low slope roofs; components where repair or replacement is very expensive if the roofing material fails in its function. The principle of both roofing insulation systems is that the insulation can...... in a different way for each component.Further development of building envelope components that through their design are prepared for repair and maintenance so that expensive repair and replacement may be avoided. Examples of components in need of such a design process could be internal insulation systems where......The dissertation consist of five parts:The purpose of the first part is to give the reader an introduction to the subjects of deterioration mechanisms, loss of function for building envelope components and prediction of service life for building envelope components.The purpose of the second part...

  14. Optimizing Computation of Repairs from Active Integrity Constraints

    DEFF Research Database (Denmark)

    Cruz-Filipe, Luís

    2014-01-01

    Active integrity constraints (AICs) are a form of integrity constraints for databases that not only identify inconsistencies, but also suggest how these can be overcome. The semantics for AICs defines different types of repairs, but deciding whether an inconsistent database can be repaired...

  15. Different surface preparation techniques of porcelain repaired with composite resin and fracture resistance

    Directory of Open Access Journals (Sweden)

    Mohd Helmy Khalid Abd Wahab

    2011-01-01

    Full Text Available Background : Porcelain from prosthesis such as crown or bridge can be fractured if exposed to trauma; and, can be repaired at chairside using composite resin. Aim : To investigate the fracture resistance of few techniques of surface preparation in repairing fractured porcelain using composite resin. Materials and Methods : Eighty samples of porcelain blocks were divided into 4 groups for different surface preparations, such as, Cimara repairing kit; porcelain etch kit containing hydrofluoric acid; Panavia F resin cement; and, sandblasting using aluminium oxide, before composite resin (Filtek Z250, 3M ESPE was bonded to the prepared porcelain blocks. Twenty others samples in the control group comprised of pure porcelain blocks. The fracture resistance of each sample was tested using Instron machine (UK. Results : With the exception of the group repaired using hydrofluoric acid (3.04±1.04 Mpa, all the other groups showed significant difference in the fracture resistance values when compared to the control group (3.05 ± 1.42 MPa at P<0.05. Conclusions : Etching of the porcelain blocks with hydrofluoric acid holds promise in the repair of fractured porcelain with composite resin at chairside.

  16. Ergonomic assessment for the task of repairing computers in a manufacturing company: A case study.

    Science.gov (United States)

    Maldonado-Macías, Aidé; Realyvásquez, Arturo; Hernández, Juan Luis; García-Alcaraz, Jorge

    2015-01-01

    Manufacturing industry workers who repair computers may be exposed to ergonomic risk factors. This project analyzes the tasks involved in the computer repair process to (1) find the risk level for musculoskeletal disorders (MSDs) and (2) propose ergonomic interventions to address any ergonomic issues. Work procedures and main body postures were video recorded and analyzed using task analysis, the Rapid Entire Body Assessment (REBA) postural method, and biomechanical analysis. High risk for MSDs was found on every subtask using REBA. Although biomechanical analysis found an acceptable mass center displacement during tasks, a hazardous level of compression on the lower back during computer's transportation was detected. This assessment found ergonomic risks mainly in the trunk, arm/forearm, and legs; the neck and hand/wrist were also compromised. Opportunities for ergonomic analyses and interventions in the design and execution of computer repair tasks are discussed.

  17. Developing a computer game to prepare children for surgery.

    Science.gov (United States)

    Rassin, Michal; Gutman, Yaira; Silner, Dina

    2004-12-01

    Computer games are a major part of the culture of children and teenagers in many developed countries. Research shows that children of the computer age prefer computer-assisted learning to any other teaching strategy. Health care workers traditionally have used dolls, games, drawings, creative arts, and even videotapes to prepare children for surgery. No studies have been conducted in Israel on using computers to help ailing children in general or to help children preparing for surgery in particular. This article discusses the potential for using computers to educate patients based on a review of the literature and interviews with children and describes the process of computer game development.

  18. Preparing Future Secondary Computer Science Educators

    Science.gov (United States)

    Ajwa, Iyad

    2007-01-01

    Although nearly every college offers a major in computer science, many computer science teachers at the secondary level have received little formal training. This paper presents details of a project that could make a significant contribution to national efforts to improve computer science education by combining teacher education and professional…

  19. Preparing Future Secondary Computer Science Educators

    Science.gov (United States)

    Ajwa, Iyad

    2007-01-01

    Although nearly every college offers a major in computer science, many computer science teachers at the secondary level have received little formal training. This paper presents details of a project that could make a significant contribution to national efforts to improve computer science education by combining teacher education and professional…

  20. Influence of surface preparation on fracture load of resin composite-based repairs

    Science.gov (United States)

    Mateos-Palacios, Rocío; Román-Rodríguez, Juan-Luis; Solá-Ruíz, María-Fernanda; Fons-Font, Antonio

    2015-01-01

    The purpose of the present study is to evaluate the fracture load of composite-based repairs to fractured zirconium oxide (Z) crowns and to ceramic-fused-to-metal (CM) crowns, comparing different mechanical surface preparation methods. A total of 75 crowns were repaired; samples then underwent dynamic loading and thermocycling. Final fracture load values for failure of the repaired crowns were measured and the type of fracture registered. Group I: CM: Surface preparation with a diamond bur + 9.5% Hydrofluoric Acid (HF) etching; Group II): CM: air-particle (Al2O3) + 9.5% HF; Group III: CM: Silica coating (SiO2); Group IV): Z: air-particle (Al2O3) + HF 9.5%; Group V) Z: Silica coating (SiO2). Of the three CM groups, Group I (CM-diamond bur) showed the highest mean failure value, with significant difference in comparison with Group III (CM-silica coating). For the zirconia groups, the highest value was obtained by Group V (silica coating). Key words:Crown, ceramic-fused-to-metal, zirconia, resin-composite, ceramic covering. PMID:25810848

  1. Influence of surface preparation on fracture load of resin composite-based repairs.

    Science.gov (United States)

    Agustín-Panadero, Rubén; Mateos-Palacios, Rocío; Román-Rodríguez, Juan-Luis; Solá-Ruíz, María-Fernanda; Fons-Font, Antonio

    2015-02-01

    The purpose of the present study is to evaluate the fracture load of composite-based repairs to fractured zirconium oxide (Z) crowns and to ceramic-fused-to-metal (CM) crowns, comparing different mechanical surface preparation methods. A total of 75 crowns were repaired; samples then underwent dynamic loading and thermocycling. Final fracture load values for failure of the repaired crowns were measured and the type of fracture registered. Group I: CM: Surface preparation with a diamond bur + 9.5% Hydrofluoric Acid (HF) etching; Group II): CM: air-particle (Al2O3) + 9.5% HF; Group III: CM: Silica coating (SiO2); Group IV): Z: air-particle (Al2O3) + HF 9.5%; Group V) Z: Silica coating (SiO2). Of the three CM groups, Group I (CM-diamond bur) showed the highest mean failure value, with significant difference in comparison with Group III (CM-silica coating). For the zirconia groups, the highest value was obtained by Group V (silica coating). Key words:Crown, ceramic-fused-to-metal, zirconia, resin-composite, ceramic covering.

  2. Computational Model of Aortic Valve Surgical Repair using Grafted Pericardium

    Science.gov (United States)

    Hammer, Peter E.; Chen, Peter C.; del Nido, Pedro J.; Howe, Robert D.

    2012-01-01

    Aortic valve reconstruction using leaflet grafts made from autologous pericardium is an effective surgical treatment for some forms of aortic regurgitation. Despite favorable outcomes in the hands of skilled surgeons, the procedure is underutilized because of the difficulty of sizing grafts to effectively seal with the native leaflets. Difficulty is largely due to the complex geometry and function of the valve and the lower distensibility of the graft material relative to native leaflet tissue. We used a structural finite element model to explore how a pericardial leaflet graft of various sizes interacts with two native leaflets when the valve is closed and loaded. Native leaflets and pericardium are described by anisotropic, hyperelastic constitutive laws, and we model all three leaflets explicitly and resolve leaflet contact in order to simulate repair strategies that are asymmetrical with respect to valve geometry and leaflet properties. We ran simulations with pericardial leaflet grafts of various widths (increase of 0%, 7%, 14%, 21% and 27%) and heights (increase of 0%, 13%, 27% and 40%) relative to the native leaflets. Effectiveness of valve closure was quantified based on the overlap between coapting leaflets. Results showed that graft width and height must both be increased to achieve proper valve closure, and that a graft 21% wider and 27% higher than the native leaflet creates a seal similar to a valve with three normal leaflets. Experimental validation in excised porcine aortas (n=9) corroborates the results of simulations. PMID:22341628

  3. Preparation, bioactivity and mechanism of nano-hydroxyapatite/sodium alginate/chitosan bone repair material.

    Science.gov (United States)

    Liao, Jianguo; Li, Yanqun; Li, Haiyan; Liu, Jingxian; Xie, Yufen; Wang, Jianping; Zhang, Yongxiang

    2017-08-11

    As the major inorganic component of natural bone, nano-hydroxyapatite (n-HA) on its own is limited in its use in bone repair, due to its brittleness. Chitosan (CS) and sodium alginate (SAL) are used to reduce its brittleness and tendency to degradation. However, the compressive strength of the composite is still low, and its biological performance needs further study. Nano-hydroxyapatite/sodium alginate/chitosan (n-HA/SAL/CS) composite was prepared via an in situ synthesis method. Further, we prepared the n-HA/SAL/CS self-setting bone repair material by mixing n-HA/SAL/CS powder with a curing liquid (20 wt.% citric acid). In addition, the in vitro bioactivity and cell cytotoxicity were also explored. Transmission electron microscopy photos revealed that the n-HA crystals were uniformly distributed throughout the polymer matrix. Infrared IR spectroscopy indicated that the HA interacted with the COO- of SAL and NH2- of CS. The compressive strength of the n-HA/SAL/CS bone cement was 34.3 MPa and matched the demands of weight-bearing bones. Soaking in vitro in simulated body fluid demonstrated that the composite material had reasonably good bioactivity, while cytotoxicity tests indicated that the n-HA/SAL/CS cement could promote cell proliferation and was biocompatible. Compressive strength of n-HA/SAL/CS can satisfy the needs of cancellous bone, and in vitro bioactivity and cytotoxicity tests results indicated that the n-HA/SAL/CS composite could act as an optimal bone repair material.

  4. The application of computer-aided designated titanium mesh in repairing skull defects

    Directory of Open Access Journals (Sweden)

    Lei ZHANG

    2015-01-01

    Full Text Available Objective To explore the clinical value of repairing skull defects with titanium alloy-mesh of computer-aided design.  Methods A retrospective analysis was done on clinical data of 86 cases with skull defects who underwent repairing using titanium mesh with two-dimensional or three-dimensional computer-aided design.  Results All the incisions achieved primary healing other than one case conducting reoperation due to exposed titanium mesh. Two cases got subcutaneous exudate, one obtained painful mastication and one experienced proliferation of scalp scar.  Conclusions With the computer-aided designated titanium mesh, relevant operation can resume the original state to maximum extent, lower surgical risk, decrease post-operational complications and then obtain satisfying clinical effect. DOI: 10.3969/j.issn.1672-6731.2015.01.015

  5. Preparation of porous PLA/DBM composite biomaterials and experimental research of repair rabbit radius segmental bone defect.

    Science.gov (United States)

    Zhang, Yumin; Wang, Jianru; Wang, Jue; Niu, Xiaojun; Liu, Jianchun; Gao, Lan; Zhai, Xiaoyan; Chu, Kaibo

    2015-12-01

    Bone substitutes are used in wide range of orthopaedic application. An ideal bone substitute should exhibit superior osteoinductive and osteoconductive properties. Neither bio-derived materials nor synthetic materials can meet the needs of an ideal bone substitute. Preparation of composite materials is a promising way to improve properties of biomaterial. In this study, the porous poly lactic acid (PLA)/demineralized bone matrix (DBM) composite biomaterials prepared by supercritical CO2 technique were implanted to repair rabbit radius segmental bone defect. By comparing with PLA and bone autograft, the X-ray result and histological analysis showed the repair effect of PLA/DBM porous composite materials is significantly better than that of the PLA group and the blank control group, and is similar to autologous bone. The PLA/DBM can promote the healing of bone defects and can be used as a kind of ideal alternative materials to repair bone defects.

  6. Preparing projected entangled pair states on a quantum computer.

    Science.gov (United States)

    Schwarz, Martin; Temme, Kristan; Verstraete, Frank

    2012-03-16

    We present a quantum algorithm to prepare injective projected entangled pair states (PEPS) on a quantum computer, a class of open tensor networks representing quantum states. The run time of our algorithm scales polynomially with the inverse of the minimum condition number of the PEPS projectors and, essentially, with the inverse of the spectral gap of the PEPS's parent Hamiltonian.

  7. Optimized distributed computing environment for mask data preparation

    Science.gov (United States)

    Ahn, Byoung-Sup; Bang, Ju-Mi; Ji, Min-Kyu; Kang, Sun; Jang, Sung-Hoon; Choi, Yo-Han; Ki, Won-Tai; Choi, Seong-Woon; Han, Woo-Sung

    2005-11-01

    As the critical dimension (CD) becomes smaller, various resolution enhancement techniques (RET) are widely adopted. In developing sub-100nm devices, the complexity of optical proximity correction (OPC) is severely increased and applied OPC layers are expanded to non-critical layers. The transformation of designed pattern data by OPC operation causes complexity, which cause runtime overheads to following steps such as mask data preparation (MDP), and collapse of existing design hierarchy. Therefore, many mask shops exploit the distributed computing method in order to reduce the runtime of mask data preparation rather than exploit the design hierarchy. Distributed computing uses a cluster of computers that are connected to local network system. However, there are two things to limit the benefit of the distributing computing method in MDP. First, every sequential MDP job, which uses maximum number of available CPUs, is not efficient compared to parallel MDP job execution due to the input data characteristics. Second, the runtime enhancement over input cost is not sufficient enough since the scalability of fracturing tools is limited. In this paper, we will discuss optimum load balancing environment that is useful in increasing the uptime of distributed computing system by assigning appropriate number of CPUs for each input design data. We will also describe the distributed processing (DP) parameter optimization to obtain maximum throughput in MDP job processing.

  8. Preparation and Characterization of Biomimetic Hydroxyapatite-Resorbable Polymer Composites for Hard Tissue Repair

    Science.gov (United States)

    Hiebner, Kristopher Robert

    Autografts are the orthopedic "gold standard" for repairing bone voids. Autografts are osteoconductive and do not elicit an immune response, but they are in short supply and require a second surgery to harvest the bone graft. Allografts are currently the most common materials used for the repair of segmental defects in hard tissue. Unlike autografts, allografts can cause an undesirable immune response and the possibility of disease transmission is a major concern. As an alternative to the above approaches, recent research efforts have focused on the use of composite materials made from hydroxyapatite (HA) and bioresorbable polymers, such as poly-L-lactide (PLLA). Recent results have shown that the surface hydroxides on HA can initiate the ring opening polymerization (ROP) of L-lactide and other lactones creating a composite with superior interfacial strength. This thesis demonstrates that the surface of porous biologically derived HA substrates, such as coralline HA and trabecular bone, can be used to initiate the ROP of L-lactide and other lactones from the vapor phase. This process increases the strength of the porous scaffold through the deposition of a thin, uniform polymer coating, while maintaining the porous structure. The kinetics of the chemical vapor deposition polymerization (CVDP) are described using a quartz crystal microbalance (QCM). The reaction temperature and monomer vapor pressure are found to affect the rate of the polymerization. Also described in this thesis is the preparation of a porous polymer scaffold that mimics the structure of demineralized bone matrix (DBM). This demineralized bone matrix simulant (DBMS) is created using anorganic bovine bone as a template to initiate the polymerization of various lactones, followed by the removal of the HA scaffold. This material retained its shape and exhibits mechanical properties superior to DBM. Finally it is shown that HA can be used to initiate the ROP of a-caprolactam and the biocompatibility

  9. Amorphous calcium phosphate nanospheres/polylactide composite coated tantalum scaffold: facile preparation, fast biomineralization and subchondral bone defect repair application.

    Science.gov (United States)

    Zhou, Rong; Xu, Wei; Chen, Feng; Qi, Chao; Lu, Bing-Qiang; Zhang, Hao; Wu, Jin; Qian, Qi-Rong; Zhu, Ying-Jie

    2014-11-01

    Calcium phosphate (CaP) materials are widely used in various biomedical areas such as drug/gene delivery and bone repair/tissue engineering. In this study, amorphous CaP nanospheres synthesized by a simple co-precipitation method are used to prepare the CaP-polylactide (CaP-PLA) composite. Then, the as-prepared CaP-PLA composite is used to coat tantalum (Ta) plates and porous scaffolds. Compared with bare Ta plate, CaP-PLA coated Ta plates show a high performance of surface biomineralization in simulated body fluid (SBF). In addition, the hydrophilicity of the CaP-PLA coated Ta plates is significantly improved. CaP-PLA coated Ta plates with bovine serum albumin (BSA) are prepared and used for the investigation of BSA release in vitro. The experimental results indicate a sustained BSA release property and simultaneous biomineralization of the as-prepared BSA-containing CaP-PLA coated Ta plates. Furthermore, CaP-PLA coated Ta scaffolds are favorable for the human osteoblast-like MG63 cells adhesion and spreading. The vascular endothelial growth factor (VEGF) and transforming growth factor (TGF)-containing CaP-PLA coated porous Ta scaffolds are used for the study of rabbit subchondral bone defect repair, covering with autogeneic periosteums. The as-prepared CaP-PLA composite coated Ta scaffolds are useful to guide the bone regeneration in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Quantitative computer-based assessment of lip symmetry following cleft lip repair.

    Science.gov (United States)

    McKearney, Richard M; Williams, John V; Mercer, Nigel S

    2013-03-01

    Objective : To demonstrate an objective method of measuring lip symmetry after cleft lip repair by comparing patients with unilateral cleft lip (UCL) to non-cleft lip controls using the SymNose computer program. Design : Retrospective cohort study comparing several parameters of lip symmetry between UCL cases and controls. Participants were represented by digital photographs that were traced using SymNose. Setting : This study was performed at the South West Cleft Unit, Bristol, U.K. Participants : Forty-four participants aged 10 years (±1 year) were recruited into and completed the study. A consecutive case series of 22 patients with UCL ± palate had previously undergone primary repair. Twenty-two age-matched controls were recruited from a local primary school. Main Outcome Measures : Lip symmetry, expressed as the percentage mismatch of an overlaying of the left upper lip area and upper vermillion border area over the right, horizontal lip tilt, and lateral deviation of the lips. Results : A significant increase in labial asymmetry was seen in the UCL group in the following parameters: upper lip mismatch and upper vermillion border mismatch. No significant differences were observed in horizontal lip tilt or lateral lip deviation. Conclusion : This study supports the use of SymNose for the objective quantitative assessment of lip symmetry as an outcome measure of surgery following cleft lip repair. It allows comparison of surgical techniques and can be used to perform audits. It is a time-efficient process, relatively inexpensive, and straightforward to use.

  11. Repair of the radial defect of rabbit with polyester/tricalcium phosphate scaffolds prepared by rapid prototyping technology

    Institute of Scientific and Technical Information of China (English)

    SUN Liang; HU Yun-yu; XIONG Zhuo; WANG Wan-ming; PAN Yu

    2006-01-01

    Objective: To evaluate the effects of repairing rabbit radial defects with polyester/tricalcium phosphate scaffolds prepared by rapid prototyping technology loaded with bovine bone morphogenetic protein (bBMP), and find new carriers for growth factors.Methods: Polyester/tricalcium phosphate scaffolds prepared by rapid prototyping technology loaded with and without bovine BMP were used to repair the 15 mm radial defect in rabbit. Then the results of radiography,histology, scaffolds degrade rates and bone mineral density(BMD) were appraised to examine the effects at the 12th week.Results: At the 12th week postoperatively, all defects treated with bBMP were radiographically repaired. No radius implanted polyester/tricalcium phosphate scaffolds without bBMP showed radiographic and histological union.At experimental groups, longitudinal alignment of lamellar structure was observed histologically at the 12th week,indicating that remodeling of regenerated bone was complete in different degree. Of the three experimental groups, the bony regeneration and remodeling of callus in poly lactide-co-glycolide/tricalcium phosphate (PLGA/TCP) group was the best. The BMD values were beyond 70% of normal value at the 12th week while the PLGA/TCP scaffolds group was the highest, and no abnormalities were observed in the surrounding soft tissue in all groups.Conclusions : Polyester/tricalciumphosphatescaffolds prepared by rapid prototyping technology loaded with bovine BMP can repair a 15 mm radial defect of rabbit. As for the results, the PLGA/TCP scaffold is ideal and better than poly L-lactide-co-D, L-lactide (PDLLA/TCP)scaffold, but the ploy L-lactic acid (PLLA/TCP) is not so good for its low degradation rates.

  12. A Web-Based Rapid Prototyping Workflow Management Information System for Computer Repair and Maintenance

    Directory of Open Access Journals (Sweden)

    A. H. El-Mousa

    2008-01-01

    Full Text Available Problem statement: Response to paper-based requests for computer and peripheral repair and maintenance has become very troublesome and slow due to the large demand and expansion at the University of Jordan. The objectives of this study were to: (i investigate the current system processes associated with the paper-based workflow system. (ii design and implement, using a suitable workflow management approach, a totally electronic alterative to improve performance. Approach: The methodology followed in the transform of the business processes from the paper to the electronic-based was using the rapid prototyping workflow management approach. This approach is seen to be especially effective in such cases where there is direct continuous interaction and involvement between the different stakeholders during the lifecycle of the project. Results: The system had been implemented and tested with the result that efficiency, accountability and response time have greatly improved in handling repair and maintenance orders. The transform from paper to electronic resulted in greatly enhanced user satisfaction especially since the developed system provided automatic feedback regarding order status. Conclusion: The design process and results provide a working blueprint for easy and quick various similar university-based business processes to be transformed to electronic. This should highly motivate internal in-house restructuring of business process to utilize technology and IT to enhance performance and accountability.

  13. Computer Forensic Function Testing: Media Preparation, Write Protection And Verification

    Directory of Open Access Journals (Sweden)

    Yinghua (David Guo

    2010-06-01

    Full Text Available Normal 0 false false false EN-US JA AR-SA The growth in the computer forensic field has created a demand for new software (or increased functionality to existing software and a means to verify that this software is truly forensic i.e. capable of meeting the requirements of the trier of fact. In this work, we review our previous work---a function oriented testing framework for validation and verification of computer forensic tools. This framework consists of three parts: function mapping, requirements specification and reference set development. Through function mapping, we give a scientific and systemical description of the fundamentals of computer forensic discipline, i.e. what functions are needed in the computer forensic investigation process. We focus this paper on the functions of media preparation, write protection and verification. Specifically, we complete the function mapping of these functions and specify their requirements. Based on this work, future work can be conducted to develop corresponding reference sets to test any tools that possess these functions.

  14. Computational fluid dynamics evaluation of the cross-limb stent graft configuration for endovascular aneurysm repair.

    Science.gov (United States)

    Shek, Tina L T; Tse, Leonard W; Nabovati, Aydin; Amon, Cristina H

    2012-12-01

    The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the "direct" and "cross" configurations, respectively). We also added a "planar" configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient's cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct

  15. Preparation and Evaluations of Mangiferin-Loaded PLGA Scaffolds for Alveolar Bone Repair Treatment Under the Diabetic Condition.

    Science.gov (United States)

    Li, Hao; Liao, Hongbing; Bao, Chongyun; Xiao, Yu; Wang, Qi

    2017-02-01

    The aim of the present study was to prepare and evaluate a sustained-release mangiferin scaffold for improving alveolar bone defect repair in diabetes. Mangiferin-loaded poly(D,L-lactide-co-glycolide) (PLGA) scaffolds were prepared using a freeze-drying technique with ice particles as the porogen material. The produced scaffolds were examined using a scanning electron microscope (SEM). Drug content and drug release were detected using a spectrophotometer. Degradation behaviors were monitored as a measure of weight loss and examined using SEM. Then, the scaffolds were incubated with rat bone marrow stromal cells under the diabetic condition in vitro, and cell viability was assessed using an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. Afterward, the scaffolds were implanted into alveolar bone defects of diabetic rats, and bone repair was examined using hematoxylin and eosin staining. The fabricated scaffolds showed porous structures, with average pore size range from 111.35 to 169.45 μm. A higher PLGA concentration led to decreased average pore size. A lower PLGA concentration or a higher mangiferin concentration resulted in increased drug content. The prepared scaffolds released mangiferin in a sustained manner with relatively low initial burst during 10 weeks. Their degradation ratios gradually increased as degradation proceeded. The mangiferin-loaded scaffolds attenuated cell viability decrease under the diabetic condition in vitro. Moreover, they increased histological scorings of bone regeneration and improved delayed alveolar bone defect healing in diabetic rats. These results suggest that the produced mangiferin-loaded scaffolds may provide a potential approach in the treatment of impaired alveolar bone healing in diabetes.

  16. Follow-up computed tomography arthrographic evaluation of bony Bankart lesions after arthroscopic repair.

    Science.gov (United States)

    Park, Jin-Young; Lee, Seung-Jun; Lhee, Sang-Hoon; Lee, Suk-Ha

    2012-04-01

    The follow-up results of bony union after an arthroscopic bony Bankart repair have not been reported. We studied follow-up computed tomography (CT) arthrograms to evaluate radiographic healing of bony Bankart fragments. Among 41 patients who underwent arthroscopy for a bony Bankart lesion between July 2006 and May 2009, 31 cases in 30 patients who had undergone sequential follow-up CT arthrography preoperatively, at 3 months postoperatively, and at 1 year postoperatively were enrolled. Radiologic patterns of fracture healing were classified into bony healing and fibrous healing. The mean age was 23.4 years, and the mean follow-up was 30.5 months. The mean interval from the first trauma to surgery was 32.5 months, and the mean preoperative dislocation number was 12.1. The mean preoperative glenoid defect was 14.1%. The fracture healing patterns included 26 bony and 5 fibrous unions. There was a significant positive relation between the total dislocation number and the preoperative glenoid defect (P = .003). The proportion of the mean fragment dimension to a circle drawn through the outer cortex of the inferior glenoid was 8.4% preoperatively, 6.6% at 3 months postoperatively, and 6.2% at 1 year postoperatively. The fragment size decreased from that measured preoperatively to the size measured 3 months after surgery (P .05). The mean Rowe score at 1 year postoperatively was 97.2. Follow-up CT arthrographic evaluation showed that small bony Bankart fragments survived without resorption until 1 year postoperatively, even with fibrous union, and that reattached bone fragment fixation to the anatomic position with the labrum could survive. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Preparation for Computer Usage in Social Work: Student Consumer Variables.

    Science.gov (United States)

    Nurius, Paula S.; And Others

    1988-01-01

    A survey of students in a large master's program in social work investigated student training in and experience with computers and attitudes about computer applications for human service activities. The value of the findings in curriculum planning, practica development, computer resources management, and faculty and agency involvement are…

  18. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.

    LENUS (Irish Health Repository)

    Manning, Brian J

    2012-02-01

    OBJECTIVES: Cumulative radiation dose, cost, and increased demand for computed tomography aortography (CTA) suggest that duplex ultrasonography (DU) may be an alternative to CTA-based surveillance. We compared CTA with DU during endovascular aneurysm repair (EVAR) follow-up. METHODS: Patients undergoing EVAR had clinical and radiological follow-up data entered in a prospectively maintained database. For the purpose of this study, the gold standard test for endoleak detection was CTA, and an endoleak detected on DU alone was assumed to be a false positive result. DU interpretation was performed independently of CTA and vice versa. RESULTS: One hundred thirty-two patients underwent EVAR, of whom 117 attended for follow-up ranging from six months to nine years (mean, 32 months). Adequate aneurysm sac visualisation on DU was not possible in 1.7% of patients, predominantly due to obesity. Twenty-eight endoleaks were detected in 28 patients during follow-up. Of these, 24 were initially identified on DU (four false negative DU examinations), and eight had at least one negative CTA with a positive DU prior to diagnosis. Twenty-three endoleaks were type II in nature and three of these patients had increased sac size. There was one type I and four type III endoleaks. Two of these (both type III) had an increased sac size. Of 12 patients with increased aneurysm size of 5 mm or more at follow-up, five had an endoleak visible on DU, yet negative CTA and a further five had endoleak visualisation on both DU and CTA. Of six endoleaks which underwent re-intervention, all were initially picked up on DU. One of these endoleaks was never demonstrated on CTA and a further two had at least one negative CTA prior to endoleak confirmation. Positive predictive value for DU was 45% and negative predictive value 94%. Specificity of DU for endoleak detection was 67% when compared with CTA, because of the large number of false positive DU results. Sensitivity for DU was 86%, with all

  19. Micro-computed tomography and histomorphometric analysis of human alveolar bone repair induced by laser phototherapy: a pilot study.

    Science.gov (United States)

    Romão, M M A; Marques, M M; Cortes, A R G; Horliana, A C R T; Moreira, M S; Lascala, C A

    2015-12-01

    Immediate dental implant placement in the molar region is critical, because of the high amount of bone loss and the discrepancy between alveolar crest thickness and the implant platform. Laser phototherapy (LPT) improves bone repair. The aim of this study was to evaluate the human alveolar bone repair 40 days after molar extraction in patients submitted to LPT. Twenty patients were selected for this randomized controlled clinical trial; 10 underwent LPT (laser group) with a GaAlAs diode laser (808 nm, 100 mW, 0.04 cm(2), 75 J/cm(2), 30s per point, 3 J per point, at five points). The control group patients (n=10) were not irradiated. Forty days later, the tissue formed inside the sockets was analyzed by micro-computed tomography and histomorphometry. Data from the two groups were compared with Student's t-test and Pearson's correlation test. The relative bone volume was significantly higher in the laser group (Palveolar bone repair after molar extraction, leading to a more homogeneous trabecular configuration represented by thin and close trabeculae.

  20. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study*

    Science.gov (United States)

    Cantador, Alex Aparecido; Siqueira, Daniel Emílio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fábio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. PMID:27777476

  1. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  2. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Directory of Open Access Journals (Sweden)

    Alex Aparecido Cantador

    Full Text Available Abstract Objective: To compare duplex ultrasound and computed tomography (CT angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01. Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation.

  3. PREPARING FOR EXASCALE: ORNL Leadership Computing Application Requirements and Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Joubert, Wayne [ORNL; Kothe, Douglas B [ORNL; Nam, Hai Ah [ORNL

    2009-12-01

    In 2009 the Oak Ridge Leadership Computing Facility (OLCF), a U.S. Department of Energy (DOE) facility at the Oak Ridge National Laboratory (ORNL) National Center for Computational Sciences (NCCS), elicited petascale computational science requirements from leading computational scientists in the international science community. This effort targeted science teams whose projects received large computer allocation awards on OLCF systems. A clear finding of this process was that in order to reach their science goals over the next several years, multiple projects will require computational resources in excess of an order of magnitude more powerful than those currently available. Additionally, for the longer term, next-generation science will require computing platforms of exascale capability in order to reach DOE science objectives over the next decade. It is generally recognized that achieving exascale in the proposed time frame will require disruptive changes in computer hardware and software. Processor hardware will become necessarily heterogeneous and will include accelerator technologies. Software must undergo the concomitant changes needed to extract the available performance from this heterogeneous hardware. This disruption portends to be substantial, not unlike the change to the message passing paradigm in the computational science community over 20 years ago. Since technological disruptions take time to assimilate, we must aggressively embark on this course of change now, to insure that science applications and their underlying programming models are mature and ready when exascale computing arrives. This includes initiation of application readiness efforts to adapt existing codes to heterogeneous architectures, support of relevant software tools, and procurement of next-generation hardware testbeds for porting and testing codes. The 2009 OLCF requirements process identified numerous actions necessary to meet this challenge: (1) Hardware capabilities must be

  4. Statistical constraints on state preparation for a quantum computer

    Indian Academy of Sciences (India)

    Subhash Kak

    2001-10-01

    Quantum computing algorithms require that the quantum register be initially present in a superposition state. To achieve this, we consider the practical problem of creating a coherent superposition state of several qubits. We show that the constraints of quantum statistics require that the entropy of the system be brought down when several independent qubits are assembled together. In particular, we have: (i) not all initial states are realizable as pure states; (ii) the temperature of the system must be reduced. These factors, in addition to decoherence and sensitivity to errors, must be considered in the implementation of quantum computers.

  5. Preparation, characterization, in vitro bioactivity, and cellular responses to a polyetheretherketone bioactive composite containing nanocalcium silicate for bone repair.

    Science.gov (United States)

    Ma, Rui; Tang, Songchao; Tan, Honglue; Qian, Jun; Lin, Wentao; Wang, Yugang; Liu, Changsheng; Wei, Jie; Tang, Tingting

    2014-08-13

    In this study, a nanocalcium silicate (n-CS)/polyetheretherketone (PEEK) bioactive composite was prepared using a process of compounding and injection-molding. The mechanical properties, hydrophilicity, and in vitro bioactivity of the composite, as well as the cellular responses of MC3T3-E1 cells (attachment, proliferation, spreading, and differentiation) to the composite, were investigated. The results showed that the mechanical properties and hydrophilicity of the composites were significantly improved by the addition of n-CS to PEEK. In addition, an apatite-layer formed on the composite surface after immersion in simulated body fluid (SBF) for 7 days. In cell culture tests, the results revealed that the n-CS/PEEK composite significantly promoted cell attachment, proliferation, and spreading compared with PEEK or ultrahigh molecular weight polyethylene (UHMWPE). Moreover, cells grown on the composite exhibited higher alkaline phosphatase (ALP) activity, more calcium nodule-formation, and higher expression levels of osteogenic differentiation-related genes than cells grown on PEEK or UHMWPE. These results indicated that the incorporation of n-CS to PEEK could greatly improve the bioactivity and biocompatibility of the composite. Thus, the n-CS/PEEK composite may be a promising bone repair material for use in orthopedic clinics.

  6. Preparation and characterization of gelatin–hydroxyapatite composite microspheres for hard tissue repair

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Shao Ching [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China); Department of Minimally Invasive Skull Neurosurgery, Neurological Institute, Taichung Veterans General Hospital, 1650 Taiwan Boulevard, Sect. 4, Taichung, Taiwan (China); Department of Neurosurgery, ChangHua Hospital, Ministry of Health and Welfare, 80 Chung Cheng Road, Sect. 2 Chiu Kuan Village, Changhua 500, Taiwan (China); Wang, Ming-Jia; Pai, Nai-Su [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China); Yen, Shiow-Kang, E-mail: skyen@dragon.nchu.edu.tw [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China)

    2015-12-01

    Gelatin–hydroxyapatite composite microspheres composed of 21% gelatin (G) and 79% hydroxyapatite (HA) with uniform morphology and controllable size were synthesized from a mixed solution of Ca(NO{sub 3}){sub 2}, NH{sub 4}H{sub 2}PO{sub 4} and gelatin by a wet-chemical method. Material analyses such as X-ray diffraction (XRD), scanning/transmission electron microscopy examination (SEM/TEM) and inductively coupled plasma-mass spectroscopy (ICP-MS) were used to characterize G–HA microspheres by analyzing their crystalline phase, microstructure, morphology and composition. HA crystals precipitate along G fibers to form nano-rods with diameters of 6–10 nm and tangle into porous microspheres after blending. The cell culture indicates that G–HA composite microspheres without any toxicity could enhance the proliferation and differentiation of osteoblast-like cells. In a rat calvarial defect model, G–HA bioactive scaffolds were compared with fibrin glue (F) and Osteoset® Bone Graft Substitute (OS) for their capacity of regenerating bone. Four weeks post-implantation, new bone, mineralization, and expanded blood vessel area were found in G–HA scaffolds, indicating greater osteoconductivity and bioactivity than F and OS. - Highlights: • G–HA composite microspheres were prepared by hydroxyapatite and gelatin. • In vitro tests indicated that the G–HA microspheres were biocompatible and bioactive. • In in vitro tests, G–HA microspheres could be applied in hard tissue engineering. • G–HA had healed the bone defect and provides a high proportion of surface area to open space.

  7. Why We Should No Longer Only Repair, Polish and Iron Current Computer Science Educations.

    Science.gov (United States)

    Gruska, Jozef

    1993-01-01

    Describes shortcomings of computer science/engineering education and explains a new focus on informatics. Highlights include simulation, visualization, algorithmization, design of information processing models, parallel computing, a history of informatics, informatics versus physics and mathematics, and implications for education. (51 references)…

  8. Impact of aortic repair based on flow field computer simulation within the thoracic aorta.

    Science.gov (United States)

    Filipovic, Nenad; Milasinovic, Danko; Zdravkovic, Nebojsa; Böckler, Dittmar; von Tengg-Kobligk, Hendrik

    2011-03-01

    Purpose of this computational study is to examine the hemodynamic parameters of velocity fields and shear stress in the thoracic aorta with and without aneurysm, based on an individual patient case and virtual surgical intervention. These two cases, case I (with aneurysm) and II (without aneurysm), are analyzed by computational fluid dynamics. The 3D Navier-Stokes equations and the continuity equation are solved with an unsteady stabilized finite element method. The vascular geometries are reconstructed based on computed tomography angiography images to generate a patient-specific 3D finite element mesh. The input data for the flow waveforms are derived from MR phase contrast flow measurements of a patient before surgical intervention. The computed results show velocity profiles skewed towards the inner aortic wall for both cases in the ascending aorta and in the aortic arch, while in the descending aorta these velocity profiles are skewed towards the outer aortic wall. Computed streamlines indicate that flow separation occurs at the proximal edge of the aneurysm, i.e. computed flow enters the aneurysm in the distal region, and that there is essentially a single, slowly rotating, vortex within the aneurysm during most of the systole. In summary, after virtual surgical intervention in case II higher shear stress distribution along the descending aorta could be found, which may produce more healthy reactions in the endothelium and benefit of vascular reconstruction of an aortic aneurysm at this particular location.

  9. Preparing ground States of quantum many-body systems on a quantum computer.

    Science.gov (United States)

    Poulin, David; Wocjan, Pawel

    2009-04-03

    Preparing the ground state of a system of interacting classical particles is an NP-hard problem. Thus, there is in general no better algorithm to solve this problem than exhaustively going through all N configurations of the system to determine the one with lowest energy, requiring a running time proportional to N. A quantum computer, if it could be built, could solve this problem in time sqrt[N]. Here, we present a powerful extension of this result to the case of interacting quantum particles, demonstrating that a quantum computer can prepare the ground state of a quantum system as efficiently as it does for classical systems.

  10. Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair

    Institute of Scientific and Technical Information of China (English)

    Xiao Yang; Yue-Xin Chen; Bo Zhang; Yu-Xin Jiang; Chang-Wei Liu; Rui-Na Zhao; Qiong Wu

    2015-01-01

    Background:Endovascular aneurysm repair (EVAR) is one of the first-line therapies of abdominal aortic aneurysms.Postoperative endoleak is the most common complication of EVAR.Computed tomography angiography (CTA),which is routine for follow-up,has side effects (e.g.,radiation) and also has a certain percentage of missed diagnosis.Preliminary studies on contrast-enhanced ultrasound (CEUS) have shown that the sensitivity of CEUS for detecting endoleak is no lower than that of CTA.To investigate the advantages of CEUS,we conducted CEUS examinations of post-EVAR cases in which CTA failed to detect endoleak or could not verify the type of endoleak.Methods:Post-EVAR patients,who were clinically considered to have endoleak and met the inclusion criteria were enrolled between March 2013 and November 2014.All of the patients underwent color Doppler flow imaging (CDFI) and a CEUS examination.Size,location,microbubble dispersion,and hemodynamic characteristics of leaks were recorded.Comparison between the diagnosis of CEUS and CDFI was conducted using Fisher's exact test and clinical outcomes of all patients were followed up.Results:Sixteen patients were enrolled,and 12 (75%) had endoleaks with verified types by CEUS.Among 12 cases of endoleaks were positive by CEUS,10 were CDFI-positive,and the four CEUS-negative cases were all negative by CDFI.The diagnostic values of CEUS and CDFI were statistically different (P =0.008).Six patients with high-pressure endoleaks received endovascular re-intervention guided by CEUS results.One patient with type Ⅲ endoleak had open surgery when endovascular repair failed.Conclusions:CEUS is a new,safe,and effective means for detection ofendoleaks post-EVAR.This technique can be used as a supplement for routine CTA follow-up to provide more detailed information on endoleak and its category.

  11. Inventing Motivates and Prepares Student Teachers for Computer-Based Learning

    Science.gov (United States)

    Glogger-Frey, I.; Kappich, J.; Schwonke, R.; Holzäpfel, L.; Nückles, M.; Renkl, A.

    2015-01-01

    A brief, problem-oriented phase such as an inventing activity is one potential instructional method for preparing learners not only cognitively but also motivationally for learning. Student teachers often need to overcome motivational barriers in order to use computer-based learning opportunities. In a preliminary experiment, we found that student…

  12. Undergraduate Taiwanese Students' Perceptions of Using Computer-Mediated Communication in a TOEIC Preparation Course

    Science.gov (United States)

    Tai, Shu-hui April

    2016-01-01

    The aim of this study is to investigate Taiwanese undergraduate students' perception of using computer-mediated communication (CMC) in a TOEIC preparation course and determine if using an online format motivates them to succeed. As a result, five factors are addressed in the study, namely, attitude, motivation, study habit, feedback, and…

  13. Replacement, refinement, and reduction: necessity of standardization and computational models for long bone fracture repair in animals.

    Science.gov (United States)

    Reifenrath, Janin; Angrisani, Nina; Lalk, Mareike; Besdo, Silke

    2014-08-01

    In the field of fracture healing it is essential to know the impacts of new materials. Fracture healing of long bones is studied in various animal models and extrapolated for use in humans, although there are differences between the micro- and macrostructure of human versus animal bone. Unfortunately, recommended standardized models for fracture repair studies do not exist. Many different study designs with various animal models are used. Concerning the general principles of replacement, refinement and reduction in animal experiments (three "Rs"), a standardization would be desirable to facilitate better comparisons between different studies. In addition, standardized methods allow better prediction of bone healing properties and implant requirements with computational models. In this review, the principles of bone fracture healing and differences between osteotomy and artificial fracture models as well as influences of fixation devices are summarized. Fundamental considerations regarding animal model choice are discussed, as it is very important to know the limitations of the chosen model. In addition, a compendium of common animal models is assembled with special focus on rats, rabbits, and sheep as most common fracture models. Fracture healing simulation is a basic tool in reducing the number of experimental animals, so its progress is also presented here. In particular, simulation of different animal models is presented. In conclusion, a standardized fracture model is of utmost importance for the best adaption of simulation to experimental setups and comparison between different studies. One of the basic goals should be to reach a consensus for standardized fracture models.

  14. Long-term Computed Tomography Follow-up After Open Surgical Repair of Abdominal Aortic Aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mantoni, M.; Neergaard, K.; Christoffersen, J. K.; Lambine, T.L.; Baekgaard, N. [Gentofte Univ. Hospital (Denmark). Depts. of Radiology and Vascular Surgery

    2006-07-15

    Purpose: To describe the findings on computed tomography (CT) of the aortic sac (AS) in patients operated on for abdominal aortic aneurysm (AAA) with insertion of a coated Dacron prosthesis. Material and Methods: A prospective study of 36 consecutive patients operated on for AAA over 2 years and followed longitudinally with CT for up to 10 years. Results: All patients had a fluid-filled AS on CT 7-10 days postoperatively. At 6 months, the AS had decreased in most patients, mainly in the antero-posterior diameter, and in two had disappeared completely. In five patients with complications, the AS increased in size. The AS disappeared completely at 10 years' follow-up in 13 patients. When present, a retroperitoneal hematoma always disappeared after 6 months. Conclusion: These data indicate that the AS after graft implantation will diminish gradually but will persist for at least 6 months. Usually the transverse diameter is bigger than the antero-posterior diameter. If the AS enlarges and becomes rounded and distended with an inhomogeneous interior, it might be a sign of graft infection. In these cases an ultrasound-guided or CT-guided puncture is recommended.

  15. Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

    OpenAIRE

    Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond

    2015-01-01

    Background Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Material/Methods Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared w...

  16. The analysis of the computer technologies used during preparation of sportsmen, specializing bodybuilding

    Directory of Open Access Journals (Sweden)

    Sedljar J.V.

    2009-10-01

    Full Text Available The generalized data about directions of information technologies use in sports practice are cited in the article. The opportunities of information-methodical system "Athlete" use in system of bodybuilder's preparation are examined in details. Program "Athlete" is a collection of tools, methods of automated data collection, processing, storage and use of information, with access to various information resources, including Internet. The prospects of computer technologies use in educational-training process of the sportsmen specializing in bodybuilding are designated.

  17. Computed tomographic measurements of mesh shrinkage after laparoscopic ventral incisional hernia repair with an expanded polytetrafluoroethylene mesh.

    Science.gov (United States)

    Schoenmaeckers, Ernst J P; van der Valk, Steef B A; van den Hout, Huib W; Raymakers, Johan F T J; Rakic, Srdjan

    2009-07-01

    The potential for shrinkage of intraperitoneally implanted meshes for laparoscopic repair of ventral and incisional hernia (LRVIH) remains a concern. Numerous experimental studies on this issue reported very inconsistent results. Expanded polytetrafluoroethylene (ePTFE) mesh has the unique property of being revealed by computed tomography (CT). We therefore conducted an analysis of CT findings in patients who had previously undergone LRVIH with an ePTFE mesh (DualMesh, WL Gore, Flagstaff, AZ, USA) in order to evaluate the shrinkage of implanted meshes. Of 656 LRVIH patients with DualMesh, all patients who subsequently underwent CT scanning were identified and only those with precisely known transverse diameter of implanted mesh and with CT scans made more than 3 months postoperatively were selected (n = 40). Two radiologists who were blinded to the size of the implanted mesh measured in consensus the maximal transverse diameter of the meshes by using the AquariusNET program (TeraRecon Inc., San Mateo, CA, USA). Mesh shrinkage was defined as the relative loss of transverse diameter as compared with the original transverse diameter of the mesh. The mean time from LRVIH to CT scan was 17.9 months (range 3-59 months). The mean shrinkage of the mesh was 7.5% (range 0-23.7%). For 11 patients (28%) there was no shrinkage at all. Shrinkage of 1-10% was found in 16 patients (40%), of 10-20% in 10 patients (25%), and of 20-24% in 3 patients (7.5%). No correlation was found regarding the elapsed time between LRVIH and CT, and shrinkage. There were two recurrences, one possibly related to shrinkage. Our observations indicate that shrinkage of DualMesh is remarkably lower than has been reported in experimental studies (8-51%). This study is the first to address the problem of shrinkage after intraperitoneal implantation of synthetic mesh in a clinical material.

  18. Early follow-up after endovascular aneurysm repair: is the first postoperative computed tomographic angiography scan necessary?

    Science.gov (United States)

    Oikonomou, Kyriakos; Ventin, Felipe C; Paraskevas, Kosmas I; Geisselsöder, Peter; Ritter, Wolfgang; Verhoeven, Eric L

    2012-04-01

    To examine whether initial postoperative computed tomographic angiography (CTA) is needed in all patients undergoing endovascular aneurysm repair (EVAR). A total of 105 consecutive patients underwent EVAR with standard infrarenal devices in our department between November 2009 and May 2011. Five patients were excluded due to severe renal insufficiency, leaving 100 (85 men; median age 73 years, range 46-91) eligible for prospective enrollment in a triple-modality early postoperative follow-up protocol [intraoperative completion angiography, postoperative duplex ultrasonography (DUS), and plain abdominal radiography). Findings were compared for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) against the first postoperative CTA results for the detection of endoleaks or other signs of EVAR failure. There were 10 inconclusive DUS examinations. In the remaining 90 patients, DUS had 75.0% sensitivity, 95.4% specificity, 85.7% PPV, and 91.5% NPV for the detection of endoleaks. The intraoperative angiogram, DUS, and abdominal radiograph combined resulted in 87.5% sensitivity and 95.4% specificity, with a 65.6% PPV and 94.8% NPV for the detection of endoleaks. In 2 patients who required a reintervention for endoleak in the early postoperative period, both endoleaks were correctly detected by the triple-modality early postoperative follow-up protocol. An early follow-up protocol consisting of an intraoperative completion angiogram, DUS, and abdominal radiograph shows a high sensitivity and NPV for the detection of endoleaks and should detect early migration or kinking of the stent-graft. An initial postoperative CTA is not necessary for most patients undergoing EVAR and should be reserved for those individuals in whom the aforementioned modalities are inconclusive or show signs of endoleak or other EVAR failure.

  19. Root Canal Anatomy Visualization using Three-Dimensional Computed- Tomography and Transparent Preparation

    Directory of Open Access Journals (Sweden)

    Alexey V. Silin

    2013-09-01

    Full Text Available Three-dimensional Computed Tomography (CT is used to analyze the topography of the root canal anatomy in order to make a decision in choosing root canal preparation method. There is a method that make extracted teeth transparent maintaining its anatomical shape and size. It is important to compare the accuracy of the two visualization methods. Objective: To compare the transmission accuracy of root canals anatomy by two visualization methods, three-dimensional CT and transparent tooth preparation. Methods: Mandibular third molar was used as sample. The three-dimensional CT scan was performed before extracting the teeth. Then teeth were extracted and placed in solutions that made them transparent. Results: Despite the fact that the character of dental origin in terms of the angle of the crown, the curvature of the crown, the deviation of the root showed in three-dimensional CT, other tooth anatomical parameters were equally well detected using a transparent tooth preparation. Overall, the curvature of the root canals is more clearly shown by transparent tooth preparation. Conclusion: Transparent tooth preparation provides superior visualization of real root canal anatomy compared to three-dimensional CT, however the later could give us more information about the relation of the tooth within the jaw.DOI: 10.14693/jdi.v20i2.152

  20. Taper Preparation Variability Compared to Current Taper Standards Using Computed Tomography

    Directory of Open Access Journals (Sweden)

    Richard Gergi

    2012-01-01

    Full Text Available Introduction. The purpose of this study was to compare the taper variation in root canal preparations among Twisted Files and PathFiles-ProTaper .08 tapered rotary files to current standards. Methods. 60 root canals with severe angle of curvature (between 25∘ and 35∘ and short radius (<10 mm were selected. The canals were divided randomly into two groups of 30 each. After preparation with Twisted Files and PathFiles-ProTaper to size 25 taper .08, the diameter was measured using computed tomography (CT at 1, 3, and 16 mm. Canal taper preparation was calculated at the apical third and at the middle-cervical third. Results. Of the 2 file systems, both fell within the ±.05 taper variability. All preparations demonstrated variability when compared to the nominal taper .08. In the apical third, mean taper was significantly different between TF and PathFiles-ProTaper ( value < 0.0001; independent -test. Mean Taper was significantly higher with PathFile-ProTaper. In the middle-cervical third, mean Taper was significantly higher with TF ( value = 0.015; independent -test. Conclusion. Taper preparations of the investigated size 25 taper .08 were favorable but different from the nominal taper.

  1. Reliability measures of a computer system with priority to PM over the H/W repair activities subject to MOT and MRT

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2015-01-01

    Full Text Available This paper concentrates on the evaluation of reliability measures of a computer system of two-identical units having independent failure of h/w and s/w components. Initially one unit is operative and the other is kept as spare in cold standby. There is a single server visiting the system immediately whenever needed. The server conducts preventive maintenance of the unit after a maximum operation time. If server is unable to repair the h/w components in maximum repair time, then components in the unit are replaced immediately by new one. However, only replacement of the s/w components has been made at their failure. The priority is given to the preventive maintenance over repair activities of the h/w. The time to failure of the components follows negative exponential distribution whereas the distribution of preventive maintenance, repair and replacement time are taken as arbitrary. The expressions for some important reliability measures of system effectiveness have been derived using semi-Markov process and regenerative point technique. The graphical behavior of the results has also been shown for a particular case.

  2. Preparation of forefinger's sequence on keyboard orients ocular fixations on computer screen.

    Science.gov (United States)

    Coutté, Alexandre; Olivier, Gérard; Faure, Sylvane; Baccino, Thierry

    2014-08-01

    This study examined the links between attention, hand movements and eye movements when performed in different spatial areas. Participants performed a visual search task on a computer screen while preparing to press two keyboard keys sequentially with their index. Results showed that the planning of the manual sequence influenced the latency of the first saccade and the placement of the first fixation. In particular, even if the first fixation placement was influenced by the combination of both components of the prepared manual sequence in some trials, it was affected principally by the first component of the prepared manual sequence. Moreover, the probability that the first fixation placement did reflect a combination of both components of the manual sequence was correlated with the speed of the second component. This finding suggests that the preparation of the second component of the sequence influence simultaneous oculomotor behavior when motor control of the manual sequence relied on proactive motor planning. These results are discussed taking into account the current debate on the eye/hand coordination research.

  3. Aircraft Metal Skin Repair and Honeycomb Structure Repair; Sheet Metal Work 3: 9857.02.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    The course helps students determine types of repairs, compute repair sizes, and complete the repair through surface protection. Course content includes goals, specific objectives, protection of metals, repairs to metal skin, and honeycomb structure repair. A bibliography and post-test are appended. A prerequisite for this course is mastery of the…

  4. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  5. Biomimetic Preparation of Magnetite/Chitosan Nanocomposite via In Situ Composite Method——Potential Use in Magnetic Tissue Repair Domain

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This study focused on the preparation of magnetic chitosan nanocomposite that has a potential application to bone repair and regeneration using an in situ composite method where chitosan membrane was used as the template and NaOH was used as the precipitant. X-ray diffraction analysis results show the formation of magnetite in the chitosan matrix. From the magnetic measurement, it could be concluded that the magnetic chitosan rods were superparamagnetic,and that this is the unique property of nanomagnetite. Macroscopical layer structure of the magnetic chitosan rods was observed from the photographs after mechanical test, and the microlayer structure of the rods was observed from the images of scanning electron microscopy. The mechanism for preparing the rods was discussed in detail. Transmission electron microscope was used to investigate the magnetite particles in the chitosan matrix and from the images it was concluded that the magnetite particles dispersed well in chitosan matrix with particle size of about 10 nm. The mechanical properties of the magnetic chitosan rods were measured and the blending strength was found to be 98.8 MPa. The mechanical properties did not decline when compared with those of the pure chitosan materials.

  6. Expanding Capacity and Promoting Inclusion in Introductory Computer Science: A Focus on Near-Peer Mentor Preparation and Code Review

    Science.gov (United States)

    Pon-Barry, Heather; Packard, Becky Wai-Ling; St. John, Audrey

    2017-01-01

    A dilemma within computer science departments is developing sustainable ways to expand capacity within introductory computer science courses while remaining committed to inclusive practices. Training near-peer mentors for peer code review is one solution. This paper describes the preparation of near-peer mentors for their role, with a focus on…

  7. Preparation

    Directory of Open Access Journals (Sweden)

    M.M. Dardir

    2014-03-01

    Full Text Available Some hexanamide-mono and di-linoleniate esters were prepared by the reaction of linolenic acid and hexanamide (derived from the reaction of hexanoic acid and diethanolamine. The chemical structure for the newly prepared hexanamide-mono and di-linoleniate esters were elucidated using elemental analysis, (FTIR, H 1NMR and chemical ionization mass spectra (CI/Ms spectroscopic techniques. The results of the spectroscopic analysis indicated that they were prepared through the right method and they have high purity. The new prepared esters have high biodegradability and lower toxicity (environmentally friendly so they were evaluated as a synthetic-based mud (ester-based mud for oil-well drilling fluids. The evaluation included study of the rheological properties, filtration and thermal properties of the ester based-muds formulated with the newly prepared esters compared to the reference commercial synthetic-based mud.

  8. Preparation and characterization of Sr-Ti-hardystonite (Sr-Ti-HT nanocomposite for bone repair application

    Directory of Open Access Journals (Sweden)

    Hossein Mohammadi

    2015-07-01

    Full Text Available Objective(s: Hardystonite (HT is Zn-modified silicate bioceramics with promising results for bone tissue regeneration. However, HT possesses no obvious apatite formation. Thus, in this study we incorporated Sr and Ti into HT to prepare Sr-Ti-hardystonite (Sr-Ti-HT nanocomposite and evaluated its in vitro bioactivity with the purpose of developing a more bioactive bone substitute material. Materials and methods:The HT and Sr-Ti-HT were prepared by mechanical milling and subsequent heat treatment. Calcium oxide (CaO, zinc oxide (ZnO and silicon dioxide (SiO2 (all from Merck were mixed with molar ratio of 2:1:2. The mixture of powders mixture was then milled in a planetary ball mill for 20 h. In the milling run, the ball-to-powder weight ratio was 10:1 and the rotational speed was 200 rpm. After synthesis of HT, 3% nanotitanium dioxide (TiO2, Degussa and 3% strontium carbonate (SrCO3, Merck were added to HT and then the mixture was ball milled and calcined at 1150°C for 6 h. Simultaneous thermal analysis (STA, X-ray diffraction (XRD, Transmission electron microscopy (TEM and Fourier transform infra-red spectroscopy (FT-IR performed to characterize the powders. Results:XRD and FT-IR confirmed the crystal phase and silicate structure of HT and TEM images demonstrated the nanostructure of powders. Further, Sr-Ti-HT induced apatite formation and showed a higher human mesenchymal stem cell (hMSCs adhesion and proliferation compared to HT. Conclusion:Our study revealed that Sr-Ti-HT with a nanostructured crystal structure of 50 nm, can be prepared by mechanical activation to use as biomaterials for orthopedic applications.

  9. Preparation of core-shell poly(L-lactic) acid-nanocrystalline apatite hollow microspheres for bone repairing applications.

    Science.gov (United States)

    Iafisco, Michele; Palazzo, Barbara; Ito, Tomoko; Otsuka, Makoto; Senna, Mamoru; Delgado-Lopez, Josè Manuel; Gomez-Morales, Jaime; Tampieri, Anna; Prat, Maria; Rimondini, Lia

    2012-11-01

    In this paper, hybrid inorganic-organic core-shell hollow microspheres, made of poly(L-lactic acid) (PLLA) and biomimetic nano apatites (HA), were prepared from biodegradable and biocompatible substances, suitable for bone tissue applications. Preparation is started from Pickering emulsification, i.e., solid particle-stabilized emulsions in the absence of any molecular surfactant, where solid particles adsorbed to an oil-water interface. Stable oil-in-water emulsions were produced using biomimetic 20 nm sized HA nanocrystals as particulate emulsifier and a dichloromethane (CH(2)Cl(2)) solution of PLLA as oil phase. Hybrid hollow PLLA microspheres at three different HA nanocrystals surface coverage, ranging from 10 to 50 μm, were produced. The resulting materials were completely characterized with spectroscopic, calorimetric and microscopic techniques and the cytocompatibility was established by indirect contact tests with both fibroblasts and osteoblasts and direct contact with these latter. They displayed a high level of cytocompatibility and thus represent promising materials for drug delivery systems, cell carriers and scaffolds for regeneration of bone useful in the treatment of orthopaedic, maxillofacial and dental fields.

  10. Computer simulation of coal preparation plants. Part 2. User's manual. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gottfried, B.S.; Tierney, J.W.

    1985-12-01

    This report describes a comprehensive computer program that allows the user to simulate the performance of realistic coal preparation plants. The program is very flexible in the sense that it can accommodate any particular plant configuration that may be of interest. This allows the user to compare the performance of different plant configurations and to determine the impact of various modes of operation with the same configuration. In addition, the program can be used to assess the degree of cleaning obtained with different coal feeds for a given plant configuration and a given mode of operation. Use of the simulator requires that the user specify the appearance of the plant configuration, the plant operating conditions, and a description of the coal feed. The simulator will then determine the flowrates within the plant, and a description of each flowrate (i.e., the weight distribution, percent ash, pyritic sulfur and total sulfur, moisture, and Btu content). The simulation program has been written in modular form using the Fortran language. It can be implemented on a great many different types of computers, ranging from large scientific mainframes to IBM-type personal computers with a fixed disk. Some customization may be required, however, to ensure compatibility with the features of Fortran available on a particular computer. Part I of this report contains a general description of the methods used to carry out the simulation. Each of the major types of units is described separately, in addition to a description of the overall system analysis. Part II is intended as a user's manual. It contains a listing of the mainframe version of the program, instructions for its use (on both a mainframe and a microcomputer), and output for a representative sample problem.

  11. Evaluation of seat and non-seat post preparation design using conventional and computational methods

    Directory of Open Access Journals (Sweden)

    G. Subrata

    2009-12-01

    Full Text Available Background: Design of root canal preparation especially in cervical-third area of the root, is one of many factors involved in the success of post-core restoration. Seat design that is used in Prosthodontics Installation, Faculty of Dentistry, University of Padjadjaran, is in the contrary to minimal preparation design. The root fracture resistance of this design has not been proven yet. Purpose: The aim of this study was to evaluate the root fracture resistance of seat compare to non-seat design, with two different research methods: experimental laboratory and computer simulation with Finite Element Method (FEM. Method: The experimental laboratory investigation used 20 upper central incisors: 10 used seat design and 10 non-seats, with the cast posts cemented in the preparation. The specimens were tested by using Universal Testing Machine with compressive force until the root fracture. The FEM used 2D digital models: seat and non-seat design of maxillary central incisors using a finite element software. The distribution of internal stress caused by static loading 110N at 135° angle with longitudinal axis of the tooth was evaluated. Result: The results of the fracture strength test showed a significant difference (p = 0.05 between the non-seat group (852.27N ± 112.6N and the seat group (495.78N ± 82.90N. The FEM showed a lower stress concentration in non-seat compare to seat group. This study proved that non-seat distributes stress better than seat design. Conclusion: It can be concluded that the FEM confirmed the result of the laboratory method. Stress concentration will cause fracture, therefore root fracture resistance in the non-seat design was higher than the seat design.

  12. 14 CFR 145.207 - Repair station manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Repair station manual. 145.207 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.207 Repair station manual. (a) A certificated repair station must prepare and follow a repair station manual acceptable to...

  13. Irrigation of human prepared root canal – ex vivo based computational fluid dynamics analysis

    Science.gov (United States)

    Šnjarić, Damir; Čarija, Zoran; Braut, Alen; Halaji, Adelaida; Kovačević, Maja; Kuiš, Davor

    2012-01-01

    Aim To analyze the influence of the needle type, insertion depth, and irrigant flow rate on irrigant flow pattern, flow velocity, and apical pressure by ex-vivo based endodontic irrigation computational fluid dynamics (CFD) analysis. Methods Human upper canine root canal was prepared using rotary files. Contrast fluid was introduced in the root canal and scanned by computed tomography (CT) providing a three-dimensional object that was exported to the computer-assisted design (CAD) software. Two probe points were established in the apical portion of the root canal model for flow velocity and pressure measurement. Three different CAD models of 27G irrigation needles (closed-end side-vented, notched open-end, and bevel open-end) were created and placed at 25, 50, 75, and 95% of the working length (WL). Flow rates of 0.05, 0.1, 0.2, 0.3, and 0.4 mL/s were simulated. A total of 60 irrigation simulations were performed by CFD fluid flow solver. Results Closed-end side-vented needle required insertion depth closer to WL, regarding efficient irrigant replacement, compared to open-end irrigation needle types, which besides increased velocity produced increased irrigant apical pressure. For all irrigation needle types and needle insertion depths, the increase of flow rate was followed by an increased irrigant apical pressure. Conclusions The human root canal shape obtained by CT is applicable in the CFD analysis of endodontic irrigation. All the analyzed values –irrigant flow pattern, velocity, and pressure – were influenced by irrigation needle type, as well as needle insertion depth and irrigant flow rate. PMID:23100209

  14. Tendon repair

    Science.gov (United States)

    Repair of tendon ... Tendon repair can be performed using: Local anesthesia (the immediate area of the surgery is pain-free) ... a cut on the skin over the injured tendon. The damaged or torn ends of the tendon ...

  15. COMPUTING

    CERN Multimedia

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  16. Recruitment, Preparation, Retention: A case study of computing culture at the University of Illinois at Urbana-Champaign

    OpenAIRE

    2007-01-01

    Computer science is seeing a decline in enrollment at all levels of education, including undergraduate and graduate study. This paper reports on the results of a study conducted at the University of Illinois at Urbana-Champaign which evaluated students attitudes regarding three areas which can contribute to improved enrollment in the Department of Computer Science: Recruitment, preparation and retention. The results of our study saw two themes. First, the department's tight research focus app...

  17. Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

    Science.gov (United States)

    Karanikola, Evridiki; Dalainas, Ilias; Karaolanis, Georgios; Zografos, Georgios; Filis, Konstantinos

    2014-01-01

    In the last decade, endovascular aneurysm repair (EVAR) has rapidly developed to be the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative mortality and morbidity but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. The purpose of this study is to review and evaluate the safety of color-duplex ultrasound (CDU) as compared with computed tomography (CT), based on the current literature, for post-EVAR surveillance. The post-EVAR follow-up modalities, CDU versus CT, are evaluated questioning three parameters: (1) accuracy of aneurysm size, (2) detection and classification of endoleaks, and (3) detection of stent-graft deformation. Studies comparing CDU with CT scan for investigation of post-EVAR complications have produced mixed results. Further and long-term research is needed to evaluate the efficacy of CDU versus CT, before CDU can be recommended as the primary imaging modality for EVAR surveillance, in place of CT for stable aneurysms. PMID:25317026

  18. Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

    Science.gov (United States)

    Karanikola, Evridiki; Dalainas, Ilias; Karaolanis, Georgios; Zografos, Georgios; Filis, Konstantinos

    2014-09-01

    In the last decade, endovascular aneurysm repair (EVAR) has rapidly developed to be the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative mortality and morbidity but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. The purpose of this study is to review and evaluate the safety of color-duplex ultrasound (CDU) as compared with computed tomography (CT), based on the current literature, for post-EVAR surveillance. The post-EVAR follow-up modalities, CDU versus CT, are evaluated questioning three parameters: (1) accuracy of aneurysm size, (2) detection and classification of endoleaks, and (3) detection of stent-graft deformation. Studies comparing CDU with CT scan for investigation of post-EVAR complications have produced mixed results. Further and long-term research is needed to evaluate the efficacy of CDU versus CT, before CDU can be recommended as the primary imaging modality for EVAR surveillance, in place of CT for stable aneurysms.

  19. The effect of apical preparation size on irrigant flow in root canals evaluated using an unsteady Computational Fluid Dynamics model

    NARCIS (Netherlands)

    Boutsioukis, C.; Gogos, C.; Verhaagen, B.; Versluis, M.; Kastrinakis, E.; van der Sluis, L.W.M.

    2010-01-01

    Aim  To evaluate the effect of apical preparation size on irrigant flow inside a root canal during final irrigation with a syringe and two different needles types, using a Computational Fluid Dynamics (CFD) model. Methodology  A validated CFD model was used to simulate the irrigant flow from either

  20. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  1. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  2. Bladder exstrophy repair

    Science.gov (United States)

    Bladder birth defect repair; Everted bladder repair; Exposed bladder repair; Repair of bladder exstrophy ... Bladder exstrophy repair involves two surgeries. The first surgery is to repair the bladder and the second one is to attach ...

  3. 口腔美容修复中牙体预备应遵循的原则及效果观察%Principle and Effect of Stomatology Cosmetology Repair Tooth Preparation

    Institute of Scientific and Technical Information of China (English)

    廖国威; 王志伟

    2014-01-01

    目的:了解口腔美容修复中牙体预备遵循的原则及应用效果。方法:选取135例口腔美容修复患者按随机数字法分成研究组70例和对照组65例。对照组遵循牙体预备的常规原则,研究组在对照组的基础上根据牙体损伤的情况实行修复治疗原则。对比两组牙体修复的效果。结果:研究组牙体修复的优良率为97.14%,对照组为87.69%,两组之间存在差异(P<0.05)。结论:在口腔美容修复中牙体预备不但应遵循常规原则,还应根据牙体的损伤情况给予治疗原则,以获得更好的修复效果。%Objective:To understand the principles and application effects of stomatology cosmetology repair tooth preparation. Methods:Selecting 135 cases of oral beauty repair patients, and randomly dividing them into 70 cases in the study group and 65 cases in the control group. The control group followed the general principle of tooth preparation, and the study group repaired the tooth according to the repair of tooth damage on the basis of the principle of treatment. Dental restorative effect of the two groups was compared. Results:The excellent and good rate of dental restoration was 97.14%, and 87.69% in the control group. There were differences between the two groups (P<0.05). Conclusion:In stomatology cosmetology repair tooth preparation should not only follow the general principle, but also be based on the damage of dental treatment principle, in order to get better effect of repair.

  4. 计算机主板故障和维修探讨%Failure and Repair of Computer Motherboard

    Institute of Scientific and Technical Information of China (English)

    于伟

    2011-01-01

    为了更好的使用电脑,本人经过查询资料,上网搜索等途径,总结了一些有关电脑主板的知识。本文就计算机主板常出现的故障和其原因以及维修处理进行论述。%In order to better use the computer, I go through the query data, Internet search and other channels,summed up some knowledge about computer motherboards.This often occurs on the computer motherboard failures and their causes,and maintenance treatment are discussed.

  5. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  6. Optimization of a Multi-Echelon Repair System Via Generalized Pattern Search With Ranking and Selection: A Computational Study

    Science.gov (United States)

    2006-03-01

    of points using Latin hypercube design or applying a few iterations of a genetic algorithm (50). For problems with computationally expensive...objective function. 2.2.4 Mixed-Variable Generalized Pattern Search. Audet and Dennis (10) pro- vided a framework for mixed-variable problems with bound and...backorders, as in Sherbrooke (48), subject to a linear cost or budget constraint. This problem is es- sentially an integer knapsack problem , containing a

  7. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  8. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  9. Computed tomography evidence of fluid in the hernia sac predicts surgical site infection following mesh repair of acutely incarcerated ventral and groin hernias.

    Science.gov (United States)

    Loftus, Tyler J; Go, Kristina L; Jordan, Janeen R; Croft, Chasen A; Smith, R Stephen; Moore, Frederick A; Efron, Philip A; Mohr, Alicia M; Brakenridge, Scott C

    2017-07-01

    Mesh placement during repair of acutely incarcerated ventral and groin hernias is associated with high rates of surgical site infection (SSI). The utility of preoperative computed tomography (CT) in this setting is unclear. We hypothesized that CT evidence of bowel wall compromise would predict SSI while accounting for physiologic parameters. We performed a 4-year retrospective cohort analysis of 50 consecutive patients who underwent mesh repair of acutely incarcerated ventral or groin hernias. We analyzed chronic disease burden, acute illness severity, CT findings, operative management, and herniorrhaphy-specific outcomes within 180 days. The primary outcome was SSI by the Centers for Disease Control and Prevention criteria. Multiple logistic regression was performed to identify independent predictors of SSI. Eighty-four percent of all patients were American Society of Anesthesiologists class III or IV, 28% were active smokers, and mean body mass index (BMI) was 35 kg/m. Fifty-four percent had ventral hernias, 40% had inguinal hernias, and 6% had femoral or combined inguinal/ femoral hernias. Seventy percent of preoperative CT scans had features suggesting bowel compromise, abdominal free fluid, or fluid in the hernia sac. Surgical site infection occurred in 32% of all patients (8% superficial, 24% deep or organ/space). The strongest predictors of SSI were CT evidence of fluid in the hernia sac (odds ratio [OR], 8.3; 95% confidence interval [CI], 1.7-41), initial heart rate 90 beats/min or greater (OR, 6.3; 95% CI, 1.1-34), and BMI 35 kg/m or greater (OR, 5.8; 95% CI, 1.2-28). Surgical site infection rates were significantly higher among patients who had CT evidence of fluid in the hernia sac (56% vs. 19%, p = 0.012). More than half of all patients with CT scan evidence of fluid in the hernia sac developed an SSI. Computed tomography evidence of fluid in the hernia sac was the strongest predictor of SSI, followed by heart rate and BMI. Together, these parameters

  10. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  11. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  12. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; Nancy Porter; Mike Sullivan; Chris Neary

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforced composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created

  13. Kvitebjoern gas pipeline repair - baptism of remote pipeline repair system

    Energy Technology Data Exchange (ETDEWEB)

    Gjertveit, Erling

    2010-07-01

    On the 1st of November 2007, severe anchor damage was discovered on the 30 inch Kvitebjoern gas export pipeline. The damage constituted a localised dent and a 17deg buckle, but no leakage. Statoil has invested in building an effective repair contingency structure for the large pipeline network on the Norwegian Continental shelf, with particular focus on the large gas export pipelines. The repair method for the Kvitebjoern pipeline was remotely operated using two Morgrip couplings and a spool. The installation used the purpose built Pipeline Repair System stored at Killingoey and couplings produced and tested back in 2005. This presentation will cover the initial damage investigations, the temporary operational phase, the repair preparations, the actual repair and lessons learned. (Author)

  14. Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control.

    Science.gov (United States)

    Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal

    2017-03-01

    Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, 30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

  15. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  16. Hypospadias repair

    Science.gov (United States)

    ... the problem. If the repair is not done, problems may occur later on such as: Difficulty controlling and directing urine stream A curve in the penis during erection Decreased fertility Embarrassment about appearance of penis Surgery ...

  17. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  18. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  19. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  20. MicroComputers: New Directions and Methods for the Preparation of Special Education Personnel.

    Science.gov (United States)

    McCann, Scott K.; Kelemen, Eve J.

    1984-01-01

    The article discusses the dual role of the microcomputer as a focus and a medium for training special educators. Current issues, applications, and outcomes surrounding the impact of microcomputer technology on the preparation of special education personnel are explored. Implications for inservice and preservice training of special educators are…

  1. Assessment of three root canal preparation techniques on root canal geometry using micro-computed tomography: In vitro study

    Directory of Open Access Journals (Sweden)

    Shaikha M Al-Ali

    2012-01-01

    Full Text Available Aim: To assess the effects of three root canal preparation techniques on canal volume and surface area using three-dimensionally reconstructed root canals in extracted human maxillary molars. Materials and Methods: Thirty extracted Human Maxillary Molars having three separate roots and similar root shape were randomly selected from a pool of extracted teeth for this study and stored in normal saline solution until used. A computed tomography scanner (Philips Brilliance CT 64-slice was used to analyze root canals in extracted maxillary molars. Specimens were scanned before and after canals were prepared using stainless steel K-Files, Ni-Ti rotary ProTaper and rotary SafeSiders instruments. Differences in dentin volume removed, the surface area, the proportion of unchanged area and canal transportation were calculated using specially developed software. Results: Instrumentation of canals increased volume and surface area. Statistical analysis found a statistically significant difference among the 3 groups in total change in volume (P = 0.001 and total change in surface area (P = 0.13. Significant differences were found when testing both groups with group III (SafeSiders. Significant differences in change of volume were noted when grouping was made with respect to canal type (in MB and DB (P < 0.05. Conclusion: The current study used computed tomography, an innovative and non destructive technique, to illustrate changes in canal geometry. Overall, there were few statistically significant differences between the three instrumentation techniques used. SafeSiders stainless steel 40/0.02 instruments exhibit a greater cutting efficiency on dentin than K-Files and ProTaper. CT is a new and valuable tool to study root canal geometry and changes after preparation in great details. Further studies with 3D-techniques are required to fully understand the biomechanical aspects of root canal preparation.

  2. Femoral hernia repair

    Science.gov (United States)

    Femorocele repair; Herniorrhaphy; Hernioplasty - femoral ... During surgery to repair the hernia, the bulging tissue is pushed back in. The weakened area is sewn closed or strengthened. This repair ...

  3. Undescended testicle repair

    Science.gov (United States)

    Orchidopexy; Inguinal orchidopexy; Orchiopexy; Repair of undescended testicle; Cryptorchidism repair ... first year of life without treatment. Undescended testicle repair surgery is recommended for patients whose testicles do ...

  4. Computer Mediated Communication in the Universal Design for Learning Framework for Preparation of Special Education Teachers

    Science.gov (United States)

    Basham, James D.; Lowrey, K. Alisa; deNoyelles, Aimee

    2010-01-01

    This study investigated the Universal Design for Learning (UDL) framework as a basis for a bi-university computer mediated communication (CMC) collaborative project. Participants in the research included 78 students from two special education programs enrolled in teacher education courses. The focus of the investigation was on exploring the…

  5. Computer- and Video-Based Instruction of Food-Preparation Skills: Acquisition, Generalization, and Maintenance

    Science.gov (United States)

    Ayres, Kevin; Cihak, David

    2010-01-01

    The purpose of this study was to evaluate the effects of a computer-based video instruction (CBVI) program to teach life skills. Three middle school-aged students with intellectual disabilities were taught how to make a sandwich, use a microwave, and set the table with a CBVI software package. A multiple probe across behaviors design was used to…

  6. The Benefits & Drawbacks of Integrating Cloud Computing and Interactive Whiteboards in Teacher Preparation

    Science.gov (United States)

    Blue, Elfreda; Tirotta, Rose

    2011-01-01

    Twenty-first century technology has changed the way tools are used to support and enhance learning and instruction. Cloud computing and interactive white boards, make it possible for learners to interact, simulate, collaborate, and document learning experiences and real world problem-solving. This article discusses how various technologies (blogs,…

  7. Of Bugs, Bytes, LANS and Viruses: The Changing Countenance of Computer Courses in Administrator Preparation Programs.

    Science.gov (United States)

    Holloway, William H.

    Instruction in computing over the past three decades has experienced dramatic changes in both method and substance. Beginning with on-the-job training, courses evolved to become highly sophisticated and widespread in education. The second decade, the 70's, focused on mainframe use, and the third decade on micros and widely networked systems.…

  8. Repairing and Upgrading Your PC

    CERN Document Server

    Thompson, Robert

    2009-01-01

    Repairing and Upgrading Your PC delivers start-to-finish instructions, simple enough for even the most inexperienced PC owner, for troubleshooting, repairing, and upgrading your computer. Written by hardware experts Robert Bruce Thompson and Barbara Fritchman Thompson, this book covers it all: how to troubleshoot a troublesome PC, how to identify which components make sense for an upgrade, and how to tear it all down and put it back together. This book shows how to repair and upgrade all of your PC's essential components.

  9. A Preparation Guide for Requests for Quotation for Tactical Data System Computer Programs

    Science.gov (United States)

    1966-11-01

    Computer Service Center 7-4 iv TABLE OP CONTENTS (Continued) Page 7.3«9 Liquidated Damages 7-5 7.3.10 Incentives 7-5 7.3.10.1 Incentives...affect costo " 8.2 Comment The exact format of the cost proposal will depend on the type of contract anticipated (i.e., CPFF, CPIF, FP, or CPAF

  10. Performance of hybrid programming models for multiscale cardiac simulations: preparing for petascale computation.

    Science.gov (United States)

    Pope, Bernard J; Fitch, Blake G; Pitman, Michael C; Rice, John J; Reumann, Matthias

    2011-10-01

    Future multiscale and multiphysics models that support research into human disease, translational medical science, and treatment can utilize the power of high-performance computing (HPC) systems. We anticipate that computationally efficient multiscale models will require the use of sophisticated hybrid programming models, mixing distributed message-passing processes [e.g., the message-passing interface (MPI)] with multithreading (e.g., OpenMP, Pthreads). The objective of this study is to compare the performance of such hybrid programming models when applied to the simulation of a realistic physiological multiscale model of the heart. Our results show that the hybrid models perform favorably when compared to an implementation using only the MPI and, furthermore, that OpenMP in combination with the MPI provides a satisfactory compromise between performance and code complexity. Having the ability to use threads within MPI processes enables the sophisticated use of all processor cores for both computation and communication phases. Considering that HPC systems in 2012 will have two orders of magnitude more cores than what was used in this study, we believe that faster than real-time multiscale cardiac simulations can be achieved on these systems.

  11. Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cesar Augusto Pereira; Pascoalato, Cristina [University of Southern Santa Catarina (UNISUL), Tubarao, SC (Brazil); Meurer, Maria Ines [Federal University of Santa Catarina (UFSC), Florianopolis, SC (Brazil); Silva, Silvio Rocha Correa, E-mail: silvio@foar.unesp.b [Sao Paulo State University (UNESP), Araraquara, SP (Brazil)

    2009-07-01

    The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a 40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 +- 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 +- 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used. (author)

  12. Intestinal obstruction repair

    Science.gov (United States)

    Repair of volvulus; Intestinal volvulus - repair; Bowel obstruction - repair ... Intestinal obstruction repair is done while you are under general anesthesia . This means you are asleep and DO NOT feel pain. ...

  13. Aortic aneurysm repair - endovascular

    Science.gov (United States)

    EVAR; Endovascular aneurysm repair - aorta; AAA repair - endovascular; Repair - aortic aneurysm - endovascular ... Endovascular aortic repair is done because your aneurysm is very large, growing quickly, or is leaking or bleeding. You may have ...

  14. Integration of Computational and Preparative Techniques to Demonstrate Physical Organic Concepts in Synthetic Organic Chemistry: An Example Using Diels-Alder Reaction

    Science.gov (United States)

    Palmer, David R. J.

    2004-01-01

    The Diels-Alder reaction is used as an example for showing the integration of computational and preparative techniques, which help in demonstrating the physical organic concepts in synthetic organic chemistry. These experiments show that the students should not accept the computational results without questioning them and in many Diels-Alder…

  15. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  16. Turbine repair process, repaired coating, and repaired turbine component

    Energy Technology Data Exchange (ETDEWEB)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  17. Preparing computers for affective communication: a psychophysiological concept and preliminary results.

    Science.gov (United States)

    Whang, Min Cheol; Lim, Joa Sang; Boucsein, Wolfram

    Despite rapid advances in technology, computers remain incapable of responding to human emotions. An exploratory study was conducted to find out what physiological parameters might be useful to differentiate among 4 emotional states, based on 2 dimensions: pleasantness versus unpleasantness and arousal versus relaxation. The 4 emotions were induced by exposing 26 undergraduate students to different combinations of olfactory and auditory stimuli, selected in a pretest from 12 stimuli by subjective ratings of arousal and valence. Changes in electroencephalographic (EEG), heart rate variability, and electrodermal measures were used to differentiate the 4 emotions. EEG activity separates pleasantness from unpleasantness only in the aroused but not in the relaxed domain, where electrodermal parameters are the differentiating ones. All three classes of parameters contribute to a separation between arousal and relaxation in the positive valence domain, whereas the latency of the electrodermal response is the only differentiating parameter in the negative domain. We discuss how such a psychophysiological approach may be incorporated into a systemic model of a computer responsive to affective communication from the user.

  18. Computational simulation and preparation of fluorescent magnetic molecularly imprinted silica nanospheres for ciprofloxacin or norfloxacin sensing.

    Science.gov (United States)

    Gao, Bo; He, Xin-Ping; Jiang, Yang; Wei, Jia-Tong; Suo, Hui; Zhao, Chun

    2014-12-01

    A magnetic molecularly imprinted fluorescent sensor for the sensitive and convenient determination of ciprofloxacin or norfloxacin in human urine was synthesized and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, ultraviolet/visible spectroscopy, and fluorescence spectroscopy. Both cadmium telluride quantum dots and ferroferric oxide nanoparticles are introduced into the polymer for the rapid separation and detection of the target molecules. The synthesized molecularly imprinted polymers were applied to detect ciprofloxacin or its structural analog norfloxacin in human urine with the detection limit 130 ng/mL. A computational study was developed to evaluate the template-monomer geometry and interaction energy in the polymerization mixture to determine the reaction molar ratio of the template and monomer molecules. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Prepare for X-Win32 - the new X11 server software for Windows computers

    CERN Multimedia

    IT Department

    2011-01-01

    Starnet X-Win32 will replace Exceed as the X11 Server software on Windows computers by February 2012. X11 Server software allows a Windows user to have a graphical user interface on a remote Linux server. This change, initially motivated by a significant change of license conditions for Exceed, brings an easier integration of Windows and Linux logon mechanisms. At the same time, X-Win32 addresses the common use cases while providing a more intuitive configuration interface. CERN Predefined Connections will be available as before. They offer an easy way of starting applications on LXPLUS using PuTTY or starting the KDE, GNOME or ICE window managers. Since X-Win32 is better integrated with SSH and CERN Kerberos compared to Exceed, it is much simpler to set up secure access to Linux services. The decision to choose X-Win32 as the new X11 software resulted from an evaluation that involved various user communities and support teams. More information, including the documented use cases, is available at https://...

  20. Concrete structures protection, repair and rehabilitation

    CERN Document Server

    Woodson, R Dodge

    2009-01-01

    The success of a repair or rehabilitation project depends on the specific plans designed for it. Concrete Structures: Protection, Repair and Rehabilitation provides guidance on evaluating the condition of the concrete in a structure, relating the condition of the concrete to the underlying cause or causes of that condition, selecting an appropriate repair material and method for any deficiency found, and using the selected materials and methods to repair or rehabilitate the structure. Guidance is also provided for engineers focused on maintaining concrete and preparing concrete investigation r

  1. A novel computer system for the evaluation of nasolabial morphology, symmetry and aesthetics after cleft lip and palate treatment. Part 2: Comparative anthropometric analysis of patients with repaired unilateral complete cleft lip and palate and healthy individuals.

    Science.gov (United States)

    Pietruski, Piotr; Majak, Marcin; Pawlowska, Elzbieta; Skiba, Adam; Antoszewski, Boguslaw

    2017-04-01

    The aim of this study was to use a novel system, 'Analyse It Doc' (A.I.D.) for a complex anthropometric analysis of the nasolabial region in patients with repaired unilateral complete cleft lip and palate and in healthy individuals. A set of standardized facial photographs in frontal, lateral and submental view have been taken in 50 non-cleft controls (mean age 20.6 years) and 42 patients with repaired unilateral complete cleft and palate (mean age 19.57 years). Then, based on linear, angular and area measurements taken from the digital photographs with the aid of the A.I.D. system, a photogrammetric analysis of intergroup differences in nasolabial morphology and symmetry was conducted. Patients with cleft lip and palate differed from the controls in terms of more than half of analysed angular measurements and proportion indices derived from linear and area measurements of the nasolabial region. The findings presented herein imply that despite primary surgical repair, patients with unilateral complete cleft lip and palate still show some degree of nasolabial dysmorphology. Furthermore, the study demonstrated that the novel computer system is suitable for a reliable, simple and time-efficient anthropometric analysis in a clinical setting. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Perirectal mucocele after imperforate anus repair

    Energy Technology Data Exchange (ETDEWEB)

    Panicek, D.M.; Leeson, S.H.; Farrar, F.M.; Hitch, D.C.

    1987-01-01

    A large perirectal mucocele developed in a child over an 11-year period following repair of an imperforate anus. Renal failure and large bowel obstruction secondary to compression by the mass were the presenting symptoms. Computed tomographic evaluation of the pelvis was critical for preoperative assessment of this previously unreported complication of imperforate anus repair.

  3. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  4. Preparation and Construction of New Phosphorus Magnesium Aluminate Cement Road Repair Agent%新型水泥混凝土道路修补剂的制备与施工

    Institute of Scientific and Technical Information of China (English)

    王鸿非; 徐波; 代小曼; 代超; 孟祥静

    2015-01-01

    This paper prepares the high early strength magnesium phosphate repair agent on the basis of using MgO,potassium dihydrogen phosphate and borax and adding mineral admixtures and steel slag powders.The crafts-manship process of pavement repair construction was put forward and applied to practical engineering.Using fly ash, silica fume,slag powders and chromium slag powders to replace partial magnesium phosphate cement,which reduces the cost and saves resources for heavy metal solidification.The engineering application shows:the initial fluidity and setting time can be controlled with less early strength loss.Thecrack permeability is better to meet the required con-struction indicators.%采用氧化镁、磷镁酸盐和硼砂为主,添加部分矿物掺和料和钢渣粉等,制备了快硬早强磷镁酸盐快硬水泥修补剂,提出了路面修补施工工艺,并应用到了实际工程中。利用矿物掺和料(粉煤灰、硅灰、膨胀剂、钢渣粉等)和铬铁矿渣粉替代部分磷镁酸盐水泥,降低了修补剂成本,节约了资源,同时有利于重金属的固化。工程应用表明:在早期强度损失率低的情况下,该修补剂的初始流动度大,凝结时间可调控,早强强度等级高,抗裂抗渗好,满足施工设计指标要求。

  5. The use of minimal preparation computed tomography for the primary investigation of colon cancer in frail or elderly patients

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Philip; Burnett, Hugh; Nicholson, David A

    2002-05-01

    AIM: To assess the place of computed tomography (CT) of the colon in frail or elderly patients with symptoms suggestive of colon cancer. METHOD: A total of 195 patients (median age 76 years) underwent CT of the abdomen and pelvis following the administration of positive oral contrast medium but no bowel preparation. All had symptoms suggestive of colon cancer. CT findings were classified as normal/diverticular disease (DD), possible colon cancer, definite colon cancer or extracolonic pathology. Accuracy of CT was assessed against patient outcome. Association between symptoms and colon cancer was assessed by chi-squared test. RESULTS: There were 47 deaths and median follow up for those alive was 16 months. Overall sensitivity of CT was 100% and specificity 87% for detection of colon cancer. One hundred and ten normal/DD CT examinations had no significant bowel lesion on follow up. Of 12 cases defined as 'definite cancers' on CT, there were nine colon cancers, two extracolonic cancers, and one normal. Of 23 'possible cancers' on CT, there were two colon cancers, three DD masses and 18 normal/DD. Fifty examinations had extracolonic findings including 33 (17%) cases of significant abdominal disease. CT findings led to a halt in investigations in 115 cases (59%), colonoscopy in 18 (9%) cases and surgery in 16 (8%) cases. None of the symptoms present showed a significant association with colon cancer (all P > 0.05). CONCLUSION: Minimal preparation CT is a non-invasive and sensitive method for investigating colon cancer in frail or elderly patients. It has a 100% negative predictive value and also detects a large number of extracolonic lesions. Robinson, P. et al. (2002)

  6. Titanium dioxide nanoparticles provide protection against polycyclic aromatic hydrocarbon BaP and chrysene-induced perturbation of DNA repair machinery: A computational biology approach.

    Science.gov (United States)

    Dhasmana, Anupam; Jamal, Qazi Mohd Sajid; Gupta, Richa; Siddiqui, Mohd Haris; Kesari, Kavindra Kumar; Wadhwa, Gulshan; Khan, Saif; Haque, Shafiul; Lohani, Mohtashim

    2016-07-01

    We examined the interaction of polycyclic hydrocarbons (PAHs) like benzo-α-pyrene (BaP), chrysene, and their metabolites 7,8-dihydro-7,8-dihydroxybenzo(a)pyrene,9,10-oxide (BPDE) and chrysene 1,2-diol-3,4-epoxide-2 (CDE), with the enzymes involved in DNA repair. We investigated interaction of 120 enzymes with PAHs and screened out 40 probable targets among DNA repair enzymes, on the basis of higher binding energy than positive control. Out of which, 20 enzymes lose their function in the presence of BaP, chrysene, and their metabolites, which may fetter DNA repair pathways resulting in damage accumulation and finally leading to cancer formation. We propose the use of nanoparticles as a guardian against the PAH's induced toxicity. PAHs enter the cell via aryl hydrocarbon receptor (AHR). TiO2 NP showed a much higher docking score with AHR (12,074) as compared with BaP and chrysene with AHR (4,600 and 4,186, respectively), indicating a preferential binding of TiO2 NP with the AHR. Further, docking of BaP and chrysene with the TiO2 NP bound AHR complex revealed their strong adsorption on TiO2 NP itself, and not on their original binding site (at AHR). TiO2 NPs thereby prevent the entry of PAHs into the cell via AHR and hence protect cells against the deleterious effects induced by PAHs.

  7. Eye muscle repair - discharge

    Science.gov (United States)

    ... Lazy eye repair - discharge; Strabismus repair - discharge; Extraocular muscle surgery - discharge ... You or your child had eye muscle repair surgery to correct eye muscle ... term for crossed eyes is strabismus. Children most often ...

  8. Ventral hernia repair

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007661.htm Ventral hernia repair To use the sharing features on this page, please enable JavaScript. Ventral hernia repair is surgery to repair a ventral hernia. ...

  9. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  10. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  11. Preparation work for the replacement of a process computer: user vision; Trabajos de preparacion para la sustitucion de un ordenador de proceso: Vision de usuario

    Energy Technology Data Exchange (ETDEWEB)

    Florit Diaz, C.

    2011-07-01

    The present paper describes the work needed to prepare the plant for its adaptation to the new system of mechanized operation support. In particular, it focuses on changes to different types of plant signals that reach the computer to conform to the requirements of the new data acquisition system.

  12. Preparation of magnetic and bioactive calcium zinc iron silicon oxide composite for hyperthermia treatment of bone cancer and repair of bone defects.

    Science.gov (United States)

    Jiang, Yumin; Ou, Jun; Zhang, Zhanhe; Qin, Qing-Hua

    2011-03-01

    In this paper, a calcium zinc iron silicon oxide composite (CZIS) was prepared using the sol-gel method. X-ray diffraction (XRD) was then employed to test the CZIS composite. The results from the test showed that the CZIS had three prominent crystalline phases: Ca(2)Fe(1.7)Zn(0.15)Si(0.15)O(5), Ca(2)SiO(4), and ZnFe(2)O(4). Calorimetric measurements were then performed using a magnetic induction furnace. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) analysis were conducted to confirm the growth of a precipitated hydroxyapatite phase after immersion in simulated body fluid (SBF). Cell culture experiments were also carried out, showing that the CZIS composite more visibly promoted osteoblast proliferation than ZnFe(2)O(4) glass ceramic and HA, and osteoblasts adhered and spread well on the surfaces of composite samples.

  13. Preparation and performance of biologic antimicrobial materials for pelvic tissue repair%生物型抗菌盆底修复材料的制备与性能

    Institute of Scientific and Technical Information of China (English)

    凌友; 徐斌; 陈晓峰

    2014-01-01

    BACKGROUND:The biological extracellular matrix materials become the focus of pelvic floor repair materials research because of its excellent biocompatibility and mechanical compatibility. However, bacterial infection can damage the function of biological repair materials. OBJECTIVE:To prepare the biologic antimicrobial materials for pelvic tissue function repair. METHODS:Chitosan and tigecycline-loaded chitosan nanoparticles suspension was prepared by the electrostatic adsorption and self-aggregation of nanoparticles preparation techniques. Then the suspension was coated onto the surface of extracellular matrix materials. The morphological examination was performed by scanning electron microscope. The antibacterial property was detected by solid plate microbial culture method. RESULTS AND CONCLUSION:Infrared spectra displayed that aromatic ring skeleton vibration peak of chitosan occurred on the biologic antimicrobial materials, and it was significantly widened at about 3 359 cm-1, indicating the composite coating was successful to modify the surface of extracellular matrix materials. As a very smal dose of tigecycline, there was no characteristic absorption peak on the infrared spectra. Scanning electron microscopy showed the porous structure of the material surface with some nanoparticles adhesion. The prepared materials had good antibacterial properties on Staphylococcus aureus and Escherichia coli, and the inhibition zone diameter was significantly increased with the increasing concentration of antibacterial agent. The biologic antimicrobial materials for pelvic tissue function repair were prepared successful y.%背景:哺乳动物细胞外基质组成的生物型修复材料,在盆底组织修复及功能重建方面表现出较大潜力,但细菌感染对生物型修复材料的功能破坏是其中的一个较大问题。  目的:制备具备抗菌功能的生物型盆底修复材料。  方法:以壳聚糖为基质材料,通过静电

  14. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  15. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  16. Dorsal variant blister aneurysm repair.

    Science.gov (United States)

    Couldwell, William T; Chamoun, Roukoz

    2012-01-01

    Dorsal variant proximal carotid blister aneurysms are treacherous lesions to manage. It is important to recognize this variant on preoperative angiographic imaging, in anticipation of surgical strategies for their treatment. Strategies include trapping the involved segment and revascularization if necessary. Other options include repair of the aneurysm rupture site directly. Given that these are not true berry aneurysms, repair of the rupture site involves wrapping or clip-grafting techniques. The case presented here was a young woman with a subarachnoid hemorrhage from a ruptured dorsal variant blister aneurysm. The technique used is demonstrated in the video and is a modified clip-wrap technique using woven polyester graft material. The patient was given aspirin preoperatively as preparation for the clip-wrap technique. It is the authors' current protocol to attempt a direct repair with clip-wrapping and leaving artery sacrifice with or without bypass as a salvage therapy if direct repair is not possible. Assessment of vessel patency after repair is performed by intraoperative Doppler and indocyanine green angiography. Intraoperative somatosensory and motor evoked potential monitoring is performed in all cases. The video can be found here: http://youtu.be/crUreWGQdGo.

  17. Virtual surgical modification for planning tetralogy of Fallot repair

    Science.gov (United States)

    Plasencia, Jonathan; Babiker, Haithem; Richardson, Randy; Rhee, Edward; Willis, Brigham; Nigro, John; Cleveland, David; Frakes, David H.

    2010-01-01

    Goals for treating congenital heart defects are becoming increasingly focused on the long-term, targeting solutions that last into adulthood. Although this shift has motivated the modification of many current surgical procedures, there remains a great deal of room for improvement. We present a new methodological component for tetralogy of Fallot (TOF) repair that aims to improve long-term outcomes. The current gold standard for TOF repair involves the use of echocardiography (ECHO) for measuring the pulmonary valve (PV) diameter. This is then used, along with other factors, to formulate a Z-score that drives surgical preparation. Unfortunately this process can be inaccurate and requires a mid-operative confirmation that the pressure gradient across the PV is not excessive. Ideally, surgeons prefer not to manipulate the PV as this can lead to valve insufficiency. However, an excessive pressure gradient across the valve necessitates surgical action. We propose the use of computational fluid dynamics (CFD) to improve preparation for TOF repair. In our study, pre-operative CT data were segmented and reconstructed, and a virtual surgical operation was then performed to simulate post-operative conditions. The modified anatomy was used to drive CFD simulation. The pressure gradient across the pulmonary valve was calculated to be 9.24mmHg, which is within the normal range. This finding indicates that CFD may be a viable tool for predicting post-operative pressure gradients for TOF repair. Our proposed methodology would remove the need for mid-operative measurements that can be both unreliable and detrimental to the patient.

  18. Computer

    CERN Document Server

    Atkinson, Paul

    2011-01-01

    The pixelated rectangle we spend most of our day staring at in silence is not the television as many long feared, but the computer-the ubiquitous portal of work and personal lives. At this point, the computer is almost so common we don't notice it in our view. It's difficult to envision that not that long ago it was a gigantic, room-sized structure only to be accessed by a few inspiring as much awe and respect as fear and mystery. Now that the machine has decreased in size and increased in popular use, the computer has become a prosaic appliance, little-more noted than a toaster. These dramati

  19. Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.

    Directory of Open Access Journals (Sweden)

    Kiamars Honardar

    2014-08-01

    Full Text Available Use of rotary Nickel-Titanium (NiTi instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography.Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA.All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex.Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry.

  20. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  1. DNA repair. [UV radiation

    Energy Technology Data Exchange (ETDEWEB)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals. (HLW)

  2. Preparing for Life in a Digital Age: The IEA International Computer and Information Literacy Study International Report

    National Research Council Canada - National Science Library

    Fraillon, Julian; Ainley, John; Schulz, Wolfram; Friedman, Tim; Gebhardt, Eveline

    2014-01-01

    ... this regard? The IEA International Computer and Information Literacy Study (ICILS) responded to this question by studying the extent to which young people have developed computer and information literacy (CIL...

  3. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  4. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  5. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  6. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  7. COMPUTING

    CERN Document Server

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  8. Proximal Contact Repair of Complex Amalgam Restorations.

    Science.gov (United States)

    Zguri, M N; Casey, J A; Jessup, J P; Vandewalle, K S

    2017-01-12

    The carving of a complex amalgam restoration may occasionally result in light proximal contact with the adjacent tooth. The purpose of this study was to investigate the strength of complex amalgam restorations repaired with a proximal slot amalgam preparation. Extracted human third molars of similar coronal size were sectioned 1 mm apical to the height of the contour using a saw and were randomly distributed into 9 groups of 10 teeth each. One pin was placed at each line angle of the flattened dentinal tooth surface. A metal matrix band was placed and an admixed alloy was condensed and carved to create a full crown contour but with a flat occlusal surface. A proximal slot was prepared with or without a retention groove and repaired using a single-composition spherical amalgam 15 minutes, 24 hours, one week, or six months after the initial crown condensation. The specimens were stored for 24 hours in 37°C water before fracture at the marginal ridge using a round-ended blade in a universal testing machine. The control group was not repaired. The mean maximum force in newtons and standard deviation were determined per group. Data were analyzed with a 2-way analysis of variance as well as Tukey and Dunnett tests (α=0.05). Significant differences were found between groups based on type of slot preparation (p=0.017) but not on time (p=0.327), with no significant interaction (p=0.152). No significant difference in the strength of the marginal ridge was found between any repair group and the unrepaired control group (p>0.076). The proximal repair strength of a complex amalgam restoration was not significantly different from an unrepaired amalgam crown. Placing a retention groove in the proximal slot preparation resulted in significantly greater fracture strength than a slot with no retention grooves. Time of repair had no significant effect on the strength of the repair.

  9. AG-NGS: a powerful and user-friendly computing application for the semi-automated preparation of next-generation sequencing libraries using open liquid handling platforms.

    Science.gov (United States)

    Callejas, Sergio; Álvarez, Rebeca; Benguria, Alberto; Dopazo, Ana

    2014-01-01

    Next-generation sequencing (NGS) is becoming one of the most widely used technologies in the field of genomics. Library preparation is one of the most critical, hands-on, and time-consuming steps in the NGS workflow. Each library must be prepared in an independent well, increasing the number of hours required for a sequencing run and the risk of human-introduced error. Automation of library preparation is the best option to avoid these problems. With this in mind, we have developed automatic genomics NGS (AG-NGS), a computing application that allows an open liquid handling platform to be transformed into a library preparation station without losing the potential of an open platform. Implementation of AG-NGS does not require programming experience, and the application has also been designed to minimize implementation costs. Automated library preparation with AG-NGS generated high-quality libraries from different samples, demonstrating its efficiency, and all quality control parameters fell within the range of optimal values.

  10. Pectus excavatum repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002949.htm Pectus excavatum repair To use the sharing features on this page, please enable JavaScript. Pectus excavatum repair is surgery to correct pectus excavatum . This ...

  11. How Prepared are Trainee Teachers of University Putra Malaysia (UPM to Integrate Computer Technology in Classroom Teaching?

    Directory of Open Access Journals (Sweden)

    Shamsiah Mohamed

    2008-01-01

    Full Text Available This research is a presentation of a study on trainee teachers' preparedness to integrate computer technology in teaching. One-hundred and thirty-nine trainee teachers participated in the study. They comprised 12.2% male students and 87.8% female. They majored in agricultural science, home-science, language, economics or accounting and science and mathematics. Their academic achievements were between 2.00 and 3.74 (Mean = 2.91, SD = 0.41. More than 50% of them felt ready to integrate computer in teaching. In general, UPM trainee teachers had positive attitudes towards the integration of computer in teaching. They had a moderately high computer efficacy. There are significant relationships between attitudes towards the integration of computers in teaching and their perceptions about their abilities to work on: data base graphics, electronic spreadsheet and word processing.

  12. Can early computed tomography angiography after endovascular aortic aneurysm repair predict the need for reintervention in patients with type II endoleak?

    Science.gov (United States)

    Dudeck, O; Schnapauff, D; Herzog, L; Löwenthal, D; Bulla, K; Bulla, B; Halloul, Z; Meyer, F; Pech, M; Gebauer, B; Ricke, J

    2015-02-01

    This study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions. We retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373-1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome. Univariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm(3); reintervention group: 3227.7 ± 2693.8 mm(3); cutoff value of 2,386 mm(3); p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a "complex type" endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02). Early CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  13. When "Other" Initiate Repair.

    Science.gov (United States)

    Schegloff, Emanuel A.

    2000-01-01

    Elaborates on the locus of other-initiated repair, and reports on a number of environments in which others initiate repair turns later than the one directly following the trouble-source turn. Describes several ways that other initiation of repair, which occurs in next-turn position, may be delayed within that position. (Author/VWL)

  14. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  15. Content-Related Repairing of Inconsistencies in Distributed Data

    Institute of Scientific and Technical Information of China (English)

    Yue-Feng Du; De-Rong Shen; Tie-Zheng Nie; Yue Kou; Ge Yu

    2016-01-01

    Conditional functional dependencies (CFDs) are a critical technique for detecting inconsistencies while they may ignore some potential inconsistencies without considering the content relationship of data. Content-related conditional functional dependencies (CCFDs) are a type of special CFDs, which combine content-related CFDs and detect potential inconsistencies by putting content-related data together. In the process of cleaning inconsistencies, detection and repairing are interactive: 1) detection catches inconsistencies, 2) repairing corrects caught inconsistencies while may bring new incon-sistencies. Besides, data are often fragmented and distributed into multiple sites. It consequently costs expensive shipment for inconsistencies cleaning. In this paper, our aim is to repair inconsistencies in distributed content-related data. We propose a framework consisting of an inconsistencies detection method and an inconsistencies repairing method, which work iteratively. The detection method marks the violated CCFDs for computing the inconsistencies which should be repaired preferentially. Based on the repairing-cost model presented in this paper, we prove that the minimum-cost repairing using CCFDs is NP-complete. Therefore, the repairing method heuristically repairs the inconsistencies with minimum cost. To improve the efficiency and accuracy of repairing, we propose distinct values and rules sequences. Distinct values make less data shipments than real data for communication. Rules sequences determine appropriate repairing sequences to avoid some incorrect repairs. Our solution is proved to be more effective than CFDs by empirical evaluation on two real-life datasets.

  16. Thermal-stress analysis of ceramic laminate veneer restorations with different incisal preparations using micro-computed tomography-based 3D finite element models.

    Science.gov (United States)

    Celebi, Alper Tunga; Icer, Esra; Eren, Meltem Mert; Baykasoglu, Cengiz; Mugan, Ata; Yildiz, Esra

    2017-11-01

    Main objective of this study is to investigate the thermal behavior of ceramic laminate veneer restorations of the maxillary central incisor with different incisal preparations such as butt joint and palatinal chamfer using finite element method. In addition, it is also aimed to understand the effect of different thermal loads which simulates hot and cold liquid imbibing in the mouth. Three-dimensional solid models of the sound tooth and prepared veneer restorations were obtained using micro-computed tomography images. Each ceramic veneer restoration was made up of ceramic, luting resin cement and adhesive layer which were generated based on the scanned images using computer-aided design software. Our solid model also included the remaining dental tissues such as periodontal ligament and surrounding cortical and spongy bones. Time-dependent linear thermal analyses were carried out to compare temperature changes and stress distributions of the sound and restored tooth models. The liquid is firstly in contact with the crown area where the maximum stresses were obtained. For the restorations, stresses on palatinal surfaces were found larger than buccal surfaces. Through interior tissues, the effect of thermal load diminished and smaller stress distributions were obtained near pulp and root-dentin regions. We found that the palatinal chamfer restoration presents comparatively larger stresses than the butt joint preparation. In addition, cold thermal loading showed larger temperature changes and stress distributions than those of hot thermal loading independent from the restoration technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Repair of mismatched basepairs in mammalian DNA

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J.H.; Hare, J.T.

    1991-08-01

    We have concentrated on three specific areas of our research plan. Our greatest emphasis is on the role of single strand nicks in influencing template strand selection in mismatch repair. We have found, that the ability of a nick in one strand to influence which strand is repaired is not a simple function of distance from the mismatched site but rather that an hot spot where a nick is more likely to have an influence can exist. The second line was production of single-genotype heteroduplexes in order to examine independently the repair of T/G and A/C mispairs within the same sequence context as in our mixed mispair preparations. We have shown preparations of supercoiled heteroduplex can be prepared that were exclusively T/G or exclusively A/C at the mispair site. The third effort has been to understand the difference in repair bias of different cell lines or different transfection conditions as it may relate to different repair systems in the cell. We have identified some of the sources of variation, including cell cycle position. We hope to continue this work to more precisely identify the phase of the cell cycle.

  18. Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, O., E-mail: oliver.dudeck@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Schnapauff, D. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Herzog, L.; Löwenthal, D.; Bulla, K.; Bulla, B. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Halloul, Z.; Meyer, F. [University of Magdeburg, Department of General, Visceral and Vascular Surgery (Germany); Pech, M. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Gebauer, B. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Ricke, J. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany)

    2015-02-15

    PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  19. Percutaneous mitral valve repair.

    Science.gov (United States)

    Gillinov, A Marc; Liddicoat, John R

    2006-01-01

    Surgical mitral valve repair is the procedure of choice to treat mitral regurgitation of all etiologies. Whereas annuloplasty is the cornerstone of mitral valve repair, a variety of other surgical techniques are utilized to correct dysfunction of the leaflets and subvalvular apparatus; in most cases, surgical repair entails application of multiple repair techniques in each patient. Preclinical studies and early human experience have demonstrated that some of these surgical repair techniques can be performed using percutaneous approaches. Specifically, there has been great progress in the development of novel technology to facilitate percutaneous annuloplasty and percutaneous edge-to-edge repair. The objectives of this report were to (1) discuss the surgical foundations for these percutaneous approaches; (2) review device design and experimental and clinical results of percutaneous valve repair; and (3) address future directions, including the key challenges of patient selection and clinical trial design.

  20. The Computer Manpower Evolution

    Science.gov (United States)

    Rooney, Joseph J.

    1975-01-01

    Advances and employment outlook in the field of computer science are discussed as well as the problems related to improving the quality of computer education. Specific computer jobs discussed include: data processing machine repairers, systems analysts, programmers, computer and peripheral equipment operators, and keypunch operators. (EA)

  1. Computed tomography angiography and magnetic resonance imaging performance of acute segmental single compartment syndrome following an Achilles tendon repair: A case report and literature review

    Institute of Scientific and Technical Information of China (English)

    Li-Feng Jiang; Hang Li; Zeng-Feng Xin; Li-Dong Wu

    2016-01-01

    Acute compartment syndrome of the lower extremity is a serious postinjury complication that requires emergency treatment.Early diagnosis is of paramount importance for a good outcome.Four muscle compartments in the calf (anterior,lateral,deep posterior,and superficial posterior) may be individually or collectively affected.Acute segmental single-compartment syndrome is an extremely rare condition characterized by high pressure in a single compartment space with threatening of the segmental tissue viability.In this case report,we describe a young man with Achilles tendon rupture who complained of postoperative pain in the anterior tibial region.Emergent computed tomography angiography and magnetic resonance imaging revealed local muscle edema.Segmental anterior compartment syndrome was diagnosed and fasciotomy was performed.

  2. Use Of Phospho Magnesium Compounds as Concrete Repair

    OpenAIRE

    2008-01-01

    International audience; Phospho magnesium compounds are tested to repair different typologies of concrete elements prepared with different surface roughness. Mechanical tests (flexion tests) show that rupture is logically conditioned by the type of preparation. SEM observations are realised along the rupture plan. The phosphate binder crystallized phases at the interface are very dense. When repaired surface is rough , the adhesion between the two phases (phosphate binder and Portland cement ...

  3. The New Learning Ecology of One-to-One Computing Environments: Preparing Teachers for Shifting Dynamics and Relationships

    Science.gov (United States)

    Spires, Hiller A.; Oliver, Kevin; Corn, Jenifer

    2012-01-01

    Despite growing research and evaluation results on one-to-one computing environments, how these environments affect learning in schools remains underexamined. The purpose of this article is twofold: (a) to use a theoretical lens, namely a new learning ecology, to frame the dynamic changes as well as challenges that are introduced by a one-to-one…

  4. Optimality in DNA repair.

    Science.gov (United States)

    Richard, Morgiane; Fryett, Matthew; Miller, Samantha; Booth, Ian; Grebogi, Celso; Moura, Alessandro

    2012-01-07

    DNA within cells is subject to damage from various sources. Organisms have evolved a number of mechanisms to repair DNA damage. The activity of repair enzymes carries its own risk, however, because the repair of two nearby lesions may lead to the breakup of DNA and result in cell death. We propose a mathematical theory of the damage and repair process in the important scenario where lesions are caused in bursts. We use this model to show that there is an optimum level of repair enzymes within cells which optimises the cell's response to damage. This optimal level is explained as the best trade-off between fast repair and a low probability of causing double-stranded breaks. We derive our results analytically and test them using stochastic simulations, and compare our predictions with current biological knowledge.

  5. Evaluation of the Transverse Craniofacial Morphology of Adolescents With Repaired Unilateral Cleft Lip and Palate Using Cone-Beam Computed Tomography.

    Science.gov (United States)

    Buyuk, Suleyman Kutalmiş; Celikoglu, Mevlut; Benkli, Yasin Atakan; Sekerci, Ahmet Ercan

    2016-10-01

    The aim of the study was to evaluate the transverse craniofacial morphology of the adolescent patients affected by unilateral cleft lip and palate (UCLP) and to compare the findings with age- and sex-matched control group without any cleft using their cone-beam computed tomography (CBCT) images. The study sample (n = 56 patients; mean age: 14.35 ± 3.06 years) consisted of 26 UCLP (n = 26 patients; 10 women and 16 men; mean age: 13.70 ± 2.94 years) and 30 control (n = 30 patients; 19 women and 11 men; mean age: 14.90 ± 3.10 years) subjects. Twenty-five conventional skeletal and dental tissue landmarks were identified. Twenty widely used frontal cephalometric variables (14 linear distances, 3 angles, and 3 ratios) were measured. The data were analyzed using the independent t-test between the groups. Patients affected by UCLP had statistically significantly smaller interorbital width (89.83 ± 4.16 mm), maxillary width (58.02 ± 5.77 mm), maxillary intermolar width (52.83 ± 4.83 mm), and upper face height (57.64 ± 4.57 mm) (P cleft width had significant effect on Cr-ANS (r = 0.446, P = 0.022) and the ANS-isf (r = 0.459, P = 0.018) measurements. The UCLP group showed statistically significantly smaller values for interorbital width, maxillary width, maxillary intermolar width, and upper face height than the noncleft controls.

  6. Composite repairs qualification according to ISO/TS 24817

    Energy Technology Data Exchange (ETDEWEB)

    Meniconi, Luiz C.M.; Perrut, Valber A. [Petroleo Brasileiro S.A. (PETROBRAS/CENPES), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2009-07-01

    Composite repairs for metallic pipes from three different suppliers were evaluated according to ISO Technical Specification TS 24817. The intended application scenarios are offshore production plants, but the design methodology is also applicable to onshore pipelines and pipework. The evaluation covered all the relevant mechanical properties and established the maximum application temperatures for each repair system. The tests also considered the application of composite repair sleeves to metallic pipes with through thickness defects, by measuring the strain energy release rates of the composite-metal interfaces. The test campaigns aimed to verify the applicability of the recently published ISO document, and to implement it as the routine procedure for composite repairs evaluation within PETROBRAS. The tests also addressed the influence of metallic pipe surface preparation on the final properties of the repair sleeves, especially in relation to the long term behavior of leaking pipes repaired by means of composite materials. (author)

  7. Composite repairs qualification according to ISO/TS 24817

    Energy Technology Data Exchange (ETDEWEB)

    Meniconi, Luiz C.M.; Perrut, Valber A. [Petroleo Brasileiro S.A. (PETROBRAS/CENPES), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2009-07-01

    Composite repairs for metallic pipes from three different suppliers were evaluated according to ISO Technical Specification TS 24817. The intended application scenarios are offshore production plants, but the design methodology is also applicable to onshore pipelines and pipework. The evaluation covered all the relevant mechanical properties and established the maximum application temperatures for each repair system. The tests also considered the application of composite repair sleeves to metallic pipes with through thickness defects, by measuring the strain energy release rates of the composite-metal interfaces. The test campaigns aimed to verify the applicability of the recently published ISO document, and to implement it as the routine procedure for composite repairs evaluation within PETROBRAS. The tests also addressed the influence of metallic pipe surface preparation on the final properties of the repair sleeves, especially in relation to the long term behavior of leaking pipes repaired by means of composite materials. (author)

  8. The Effect of Preparation Design on the Fracture Resistance of Zir-Conia Crown Copings (Computer Associated Design/Computer Associated Machine, CAD/CAM System

    Directory of Open Access Journals (Sweden)

    B. Atashkar

    2011-09-01

    Full Text Available Objective: One of the major problems of all ceramic restorations is their probable fracture against the occlusal force. The aim of the present in-vitro study is was to compare the effect of two marginal designs (chamfer & shoulder on the fracture resistance of zirconia copings, CERCON (CAD/CAM.MATERIALS AND METHODS: This in vitro study was done with single blind experimental technique. One stainless steel dye with 50’ chamfer finish line design (0.8 mm depth was prepared using milling machine. Ten epoxy resin dyes were made, The same dye was retrieved and 50' chamfer was converted into shoulder (1 mm.again ten epoxy resin dyes were made from shoulder dyes. Zirconia cores with 0.4 mm thickness and 35 µm cement Space fabricated on the20 epoxy resin dyes (10 samples chamfer and 10 samples shoulder in a dental laboratory. Then the zirconia cores were cemented on the epoxy resin dyes and underwent a fracture test with a universal testing machine (GOTECH AI-700LAC, Arson, USA and samples were investigated from the point of view of the origin of the failure.RESULT: The mean value of fracture resistance for shoulder margins were 788.90±99.56 N and for the chamfer margins were 991.75±112.00 N. The student’s T-test revealed a statistically significant difference between groups (P=0.001.CONCLUSION: The result of this study indicates that marginal design of the zirconia cores effects on their fracture resistance. A chamfer margin could improve the biomechanical performance of posterior single zirconia crown restorations. This may be because of strong unity and round internal angle in chamfer margin.

  9. Preparing systems engineering and computing science students in disciplined methods, quantitative, and advanced statistical techniques to improve process performance

    Science.gov (United States)

    McCray, Wilmon Wil L., Jr.

    The research was prompted by a need to conduct a study that assesses process improvement, quality management and analytical techniques taught to students in U.S. colleges and universities undergraduate and graduate systems engineering and the computing science discipline (e.g., software engineering, computer science, and information technology) degree programs during their academic training that can be applied to quantitatively manage processes for performance. Everyone involved in executing repeatable processes in the software and systems development lifecycle processes needs to become familiar with the concepts of quantitative management, statistical thinking, process improvement methods and how they relate to process-performance. Organizations are starting to embrace the de facto Software Engineering Institute (SEI) Capability Maturity Model Integration (CMMI RTM) Models as process improvement frameworks to improve business processes performance. High maturity process areas in the CMMI model imply the use of analytical, statistical, quantitative management techniques, and process performance modeling to identify and eliminate sources of variation, continually improve process-performance; reduce cost and predict future outcomes. The research study identifies and provides a detail discussion of the gap analysis findings of process improvement and quantitative analysis techniques taught in U.S. universities systems engineering and computing science degree programs, gaps that exist in the literature, and a comparison analysis which identifies the gaps that exist between the SEI's "healthy ingredients " of a process performance model and courses taught in U.S. universities degree program. The research also heightens awareness that academicians have conducted little research on applicable statistics and quantitative techniques that can be used to demonstrate high maturity as implied in the CMMI models. The research also includes a Monte Carlo simulation optimization

  10. Repairs of composite structures

    Science.gov (United States)

    Roh, Hee Seok

    Repair on damaged composite panels was conducted. To better understand adhesively bonded repair, the study investigates the effect of design parameters on the joint strength. The design parameters include bondline length, thickness of adherend and type of adhesive. Adhesives considered in this study were tested to measure their tensile material properties. Three types of adhesively bonded joints, single strap, double strap, and single lap joint were considered under changing bondline lengths, thickness of adherend and type of adhesive. Based on lessons learned from bonded joints, a one-sided patch repair method for composite structures was conducted. The composite patch was bonded to the damaged panel by either film adhesive FM-73M or paste adhesive EA-9394 and the residual strengths of the repaired specimens were compared under varying patch sizes. A new repair method using attachments has been suggested to enhance the residual strength. Results obtained through experiments were analyzed using finite element analysis to provide a better repair design and explain the experimental results. It was observed that the residual strength of the repaired specimen was affected by patch length. Method for rapid repairs of damaged composite structures was investigated. The damage was represented by a circular hole in a composite laminated plate. Pre-cured composite patches were bonded with a quick-curing commercial adhesive near (rather than over) the hole. Tensile tests were conducted on specimens repaired with various patch geometries. The test results showed that, among the methods investigated, the best repair method restored over 90% of the original strength of an undamaged panel. The interfacial stresses in the adhesive zone for different patches were calculated in order to understand the efficiencies of the designs of these patch repairs. It was found that the composite patch that yielded the best strength had the lowest interfacial peel stress between the patch and

  11. Augmented Reality Repair Guidance System

    Directory of Open Access Journals (Sweden)

    Sidharth Bhatia

    2012-07-01

    Full Text Available The daily life of a common man revolves around various forms of appliances/gadgets he uses throughout the day such as a mobile phone, laptop, printer, microwave oven, washing machine, etc. Although these appliances/gadgets are taken by most of the people for granted, the problem occurs when any of these things do not work as they are expected to. Getting them to the repair shops for every small glitch is expensive as well as time consuming. Although most of the companies which produce these appliances/gadgets do supply them with basic manuals, which deal with how to solve these minor issues, but reading them and at the same time repairing the corresponding appliance/gadget can be a frustrating task at times. These problems can be reduced to a large extent if some kind of live guidance is available. In this paper we propose a method to do so with the help of an augmented reality based system that will guide the user to carry out small scale repair jobs on these gadgets. All that is required is a decent webcam and a computing device, with a processor of 1 GHz or more and a display screen.

  12. Preparation, spectral, X-ray powder diffraction and computational studies and genotoxic properties of new azo-azomethine metal chelates

    Science.gov (United States)

    Bitmez, Şirin; Sayin, Koray; Avar, Bariş; Köse, Muhammet; Kayraldız, Ahmet; Kurtoğlu, Mükerrem

    2014-11-01

    A new tridentate azo-azomethine ligand, N‧-[{2-hydroxy-5-[(4-nitrophenyl)diazenyl]phenyl}methylidene]benzohydrazidemonohydrate, (sbH·H2O) (1), is prepared by condensation of benzohydrazide and 2-hydroxy-5-[(4-nitrophenyl)diazenyl]benzaldehyde (a) with treatment of a solution of diazonium salt of p-nitroaniline and 2-hydroxybenzaldehyde in EtOH. The five coordination compounds, [Co(sb)2]·4H2O (2), [Ni(sb)2]·H2O (3), [Cu(sb)2]·4H2O (4), [Zn(sb)2]·H2O (5) and [Cd(sb)2]·H2O (6) are prepared by reacting the Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) ions with the ligand. The structures of the compounds are elucidated from the elemental analyses data and spectroscopic studies. It is found the ligand acts as a tridentate bending through phenolic and carbonyl oxygens and nitrogen atom of the Cdbnd Nsbnd group similar to the most of salicylaldimines. Comparison of the infrared spectra of the ligand and its metal complexes confirm that azo-Schiff base behaves as a monobasic tridentate ligand towards the central metal ion with an ONO donor sequence. Upon complexation with the ligand, the Cd(II), and Zn(II) ions form monoclinic structures, while Co(II), Cu(II) and Ni(II) ions form orthorhombic structures. Quantum chemical calculations are performed on tautomers and its metal chelates by using DFT/B3LYP method. Most stable tautomer is determined as tautomer (1a). The geometrical parameters of its metal chelates are obtained as theoretically. The NLO properties of tautomer (1a) and its metal complexes are investigated. Finally, the ligand and its metal complexes are assessed for their genotoxicity.

  13. Workshop on DNA repair.

    NARCIS (Netherlands)

    A.R. Lehmann (Alan); J.H.J. Hoeijmakers (Jan); A.A. van Zeeland (Albert); C.M.P. Backendorf (Claude); B.A. Bridges; A. Collins; R.P.D. Fuchs; G.P. Margison; R. Montesano; E. Moustacchi; A.T. Natarajan; M. Radman; A. Sarasin; E. Seeberg; C.A. Smith; M. Stefanini (Miria); L.H. Thompson; G.P. van der Schans; C.A. Weber (Christine); M.Z. Zdzienika

    1992-01-01

    textabstractA workshop on DNA repair with emphasis on eukaryotic systems was held, under the auspices of the EC Concerted Action on DNA Repair and Cancer, at Noordwijkerhout (The Netherlands) 14-19 April 1991. The local organization of the meeting was done under the auspices of the Medical Genetic C

  14. Laparoscopic lumbar hernia repair.

    Science.gov (United States)

    Madan, Atul K; Ternovits, Craig A; Speck, Karen E; Pritchard, F Elizabeth; Tichansky, David S

    2006-04-01

    Lumbar hernias are rare clinical entities that often pose a challenge for repair. Because of the surrounding anatomy, adequate surgical herniorraphy is often difficult. Minimally invasive surgery has become an option for these hernias. Herein, we describe two patients with lumbar hernias (one with a recurrent traumatic hernia and one with an incisional hernia). Both of these hernias were successfully repaired laparoscopically.

  15. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  16. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Bill Bruce; Nancy Porter; George Ritter; Matt Boring; Mark Lozev; Ian Harris; Bill Mohr; Dennis Harwig; Robin Gordon; Chris Neary; Mike Sullivan

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  17. Upgrading and Fixing Computers Do-it-Yourself for Dummies

    CERN Document Server

    Rathbone, Andy

    2010-01-01

    An illustrated, step-by-step guide to repairs and upgrades. Whether you want to prepare your computer for Windows 7, avoid investing in a new one, or just "go green", this fully illustrated guide has what you need. You'll learn how to add printers and new keyboards, boost your PC's performance and increase memory, improve power consumption, rev up your multimedia capacity, and much more. Step-by-step instructions are accompanied by photos that show you exactly what you should see at every stage.: Learn to perform basic upgrades and prepare your PC for high-speed Internet connections,

  18. Guided access cavity preparation using cone-beam computed tomography and optical surface scans - an ex vivo study

    DEFF Research Database (Denmark)

    Buchgreitz, J; Buchgreitz, M; Mortensen, D

    2016-01-01

    . An apical canal preparation was created to simulate remnants of an apical root canal that acted as the target for a drill path. The test blocks were surface scanned, and merged with a CBCT scan, and a guide rail was made. A pathway for the bur was created through a metal sleeve within the guide rail...... into dentine. The distance was measured between the centres of the performed drill path and the apical target by two examiners. A maximum distance of 0.7 mm was defined based on the radius of the bur (0.6 mm) and the radius of a root canal just visible on a radiograph (0.1 mm). The t-test was used...... for evaluation, and intra- and inter-examiner reproducibility was expressed by intraclass correlation coefficients. RESULTS: The mean distance between the drill path and the target was significantly lower than 0.7 mm, and null hypothesis H0 : μ = 0.7 was rejected (CI 95%: 0.31;0.49, P

  19. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  20. Effect of chemical surface treatments and repair material on transverse strength of repaired acrylic denture resin

    Directory of Open Access Journals (Sweden)

    Vojdani Mahroo

    2008-01-01

    Full Text Available Purpose: This study was performed to evaluate the transverse strength of a denture base resin (H, repaired with an autopolymerizing acrylic resin (A or a visible light-curing (VLC resin (T following the use of three chemical solvents: methyl methacrylate monomer, aceton or chloroform. Materials and Methods: Eighty specimens (65.0 x 10.0 x 3.3 mm of H were fabricated and stored in distilled water at 37°C for seven days. Specimens were divided into eight equal groups of 10. In each group, specimens were sectioned in the middle to create a 10 mm gap. Two groups served as controls and had no surface treatment. They were repaired with A or T materials. In the remaining six experimental groups, specimen surfaces were treated with ac for 30 sec or mma for 180 sec or ch for 5 sec. Then A or T material was placed on the treated surfaces, using the same preparation molds. After seven days′ storage at 37°C, the transverse bond strength (MPa of the specimens was measured using a three-point bending test. A two-way ANOVA and a Tukey HSD were performed to identify significant differences ( P < 0.05. The nature of the failures was noted as adhesive, cohesive or mixed. Results: Significant differences were found between the controls and experimental groups ( P < 0.05. In the control groups, repair with A showed significantly higher strength (60.3 MPa than those repaired with T (51.3 MPa. Mean transverse strength of experimental specimens repaired with A was (75.06 MPa which was significantly greater than those repaired with T (67.9 MPa. Although surface treatment increased repair strength, no significant differences were detected between the effects of the chemical etchants. Conclusions: The autopolymerizing resin exhibited significantly higher repair strength than VLC resin. The transverse strength of the repaired specimens was increased significantly after chemical treatments.

  1. X-ray computed tomography contrast agents prepared by seeded growth of gold nanoparticles in PEGylated dendrimer

    Science.gov (United States)

    Kojima, Chie; Umeda, Yasuhito; Ogawa, Mikako; Harada, Atsushi; Magata, Yasuhiro; Kono, Kenji

    2010-06-01

    Gold nanoparticles (Au NPs) are a potential x-ray computed tomography (CT) contrast agent. A biocompatible and bioinactive surface is necessary for application of gold nanoparticle to CT imaging. Polyethylene glycol (PEG)-attached dendrimers have been used as a drug carrier with long blood circulation. In this study, the Au NPs were grown in the PEGylated dendrimer to produce a CT contrast agent. The Au NPs were grown by adding gold ions and ascorbic acid at various equivalents to the Au NP-encapsulated dendrimer solution. Both size and surface plasmon absorption of the grown Au NPs increased with adding a large number of gold ions. The x-ray attenuation of the Au NPs also increased after the seeded growth. The Au NPs grown in the PEG-attached dendrimer at the maximum under our conditions exhibited a similar CT value to a commercial iodine agent, iopamidol, in vitro. The Au NP-loaded PEGylated dendrimer and iopamidol were injected into mice and CT images were obtained at different times. The Au NP-loaded PEGylated dendrimer achieved a blood pool imaging, which was greater than a commercial iodine agent. Even though iopamidol was excreted rapidly, the PEGylated dendrimer loading the grown Au NP was accumulated in the liver.

  2. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners

  3. Micro-computed Tomography Assessment of Dentinal Micro-cracks after Root Canal Preparation with TRUShape and Self-adjusting File Systems.

    Science.gov (United States)

    Zuolo, Mario Luis; De-Deus, Gustavo; Belladonna, Felipe Gonçalves; Silva, Emmanuel João Nogueira Leal da; Lopes, Ricardo Tadeu; Souza, Erick Miranda; Versiani, Marco Aurélio; Zaia, Alexandre Augusto

    2017-04-01

    The aim of the present study was to evaluate the percentage frequency of dentinal micro-cracks observed after root canal preparation with TRUShape and Self-Adjusting File (SAF) systems by means of micro-computed tomography imaging analysis. A conventional full-sequence rotary system (BioRace) and a single-file reciprocation system (Reciproc) were used as reference techniques for comparison because of their known assertive cutting efficiency. Forty anatomically matched mandibular incisors were selected, scanned at a resolution of 14.25 μm, and assigned to 4 experimental groups (n = 10), according to the preparation protocol: TRUShape, SAF, BioRace, and Reciproc systems. After the experimental procedures, the specimens were scanned again, and the registered preoperative and postoperative cross-section images of the roots (n = 70,030) were screened to identify the presence of dentinal micro-cracks. Overall, dentinal defects were observed in 28,790 cross-section images (41.11%). In the TRUShape, SAF, BioRace, and Reciproc groups, dentinal micro-cracks were visualized in 56.47% (n = 9842), 42.38% (n = 7450), 32.90% (n = 5826), and 32.77% (n = 5672) of the slices, respectively. All dentinal defects observed in the postoperative data sets were already present in the corresponding preoperative images. None of the preparation systems induced the formation of new dentinal micro-cracks. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Salvage hypospadias repairs

    Directory of Open Access Journals (Sweden)

    Sripathi V

    2008-01-01

    Full Text Available Aim: Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. Methods: This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children - buccal mucosal grafts (BMGs in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. Results: The age of children ranged from 1.5-15 years (mean 4.5. Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50% with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely - a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. Conclusions: In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4-6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised.

  5. Computer Assisted Educational Material Preparation for Fourth Grade Primary School Students’ English Language Class in Teaching Numbers

    Directory of Open Access Journals (Sweden)

    Abdulkadir Yüzen

    2016-03-01

    Full Text Available In this study, using ADDIE instructional design model, it is aimed to prepare English language educational material for 4th grade primary students to teach them numbers. At the same time, ARCS model of motivation’s attention, relevance and satisfaction phases are also taken into consideration. This study also comprises of Design Based Research which includes design, theory and application processes. The first phase of the ADDIE method is the analysis where there is a discussion with primary school English language teachers so as to determine the topic, the content and the target groups. During the design phase; objectives, strategies, activities, assessments, and methods of learning are determined to organize and present the content on the basis of learning objectives. In the development phase; images, animations and user interface are created in accordance with students’ ages. Additionally, sounds including the pronunciation of digits and numbers are created and the codes of the visual scenarios that are designed are written in ActionScript 2.0 in Adobe Flash CS3 Professional. At the implementation phase, some of the target group students are tested with prototype material that has been implemented. In the classroom, students learn both the pronunciation and the spelling of the numbers. After checking their spelling and typing errors of numbers with quizzes, the students repeat what they have learned and then they take the spelling quizzes. The program checks the misspelled words. Students who correctly complete the quizzes are entitled to have one flag. And when they have all the flags (4 flag, they receive a certificate of achievement. With this rewarding technique, it is intended to raise the motivation of the students. Finally, at the evaluation step, the observed problems in the materials are revised. At every stage of the process, expert evaluations are consulted. With this study that is based on ADDIE instructional designed model and

  6. Novel Repair Concept for Composite Materials by Repetitive Geometrical Interlock Elements

    Directory of Open Access Journals (Sweden)

    David Zaremba

    2011-12-01

    Full Text Available Material adapted repair technologies for fiber-reinforced polymers with thermosetting matrix systems are currently characterized by requiring major efforts for repair preparation and accomplishment in all industrial areas of application. In order to allow for a uniform distribution of material and geometrical parameters over the repair zone, a novel composite interlock repair concept is introduced, which is based on a repair zone with undercuts prepared by water-jet technology. The presented numerical and experimental sensitivity analyses make a contribution to the systematic development of the interlock repair technology with respect to material and geometrical factors of influence. The results show the ability of the novel concept for a reproducible and automatable composite repair.

  7. Tissue-engineered acellular matrix material:preparation and application in articular cartilage repair%脱细胞基质材料制备方法及在骨关节软骨损伤修复中的应用

    Institute of Scientific and Technical Information of China (English)

    赵玉果; 李明明

    2016-01-01

      结果与结论:①脱细胞基质组织工程材料交联后呈现为深蓝色,疏松多孔,直径为5 mm,硬度适中,具备一定的弹性;②苏木精-伊红染色不含有细胞碎屑及蓝染的核物质,不存在残留的细胞外基质;③甲苯胺蓝染色为蓝色材料支架孔隙率为90%,溶胀率为(1314±337)%;④脱细胞基质组织组材料1,3,5,7,9 d的A值显著高于纤维样组织组(P OBJECTIVE:To investigate the effect of tissue-engineered acelular matrix in articular cartilage repair. METHODS:Totaly 30 New Zealand rabbits were randomly alottedto fibroid tissue andacelular matrix groups (n=15 per group), and then articular cartilage defect models,4mmin diameter,were established at the white rabbitfemoral condyle. Acelular cartilage matrix scaffold was prepared using bovine knee cartilage, and model rats in the acelular matrix group were repaired with acelular cartilage matrix scaffold and the others in the fibroid tissue group repaired with fibroid tissues. Finaly, repair effects between two groups were compared. RESULTS AND CONCLUSION:The dark blue and porous tissue-engineered acelular matrix material could be found, with a diameter of 5mm and moderate hardness, and exhibited certain flexibility after cross-linking. Hematoxylin-eosin staining showed that cel debris,blue-stainednuclear materials and residual extracelular matrix disappeared. Toluidine blue staining found that the porosity of the blue scaffold was 90%, and the sweling ratio was (1314±337)%. The absorbance value in the acelular matrix group was significantly higher than that in the fibroid tissue group at 1, 3, 5, 7 and 9 days (P< 0.05). In the fibroid tissue group,defectsfiled withnewborn fibrous scars were overt. By contrast, in the acelularmatrix group, the white tissuescovered the defect regionwith smooth surface,and the woundwas basicaly healed,withanunclearboundaryafter 12weeks. Moreover, blue-stained, smal flattened cels appeared

  8. Progress of peripheral nerve repair

    Institute of Scientific and Technical Information of China (English)

    陈峥嵘

    2002-01-01

    Study on repair of peripheral nerve injury has been proceeding over a long period of time. With the use of microsurgery technique since 1960s,the quality of nerve repair has been greatly improved. In the past 40 years, with the continuous increase of surgical repair methods, more progress has been made on the basic research of peripheral nerve repair.

  9. Achilles tendon repair

    Science.gov (United States)

    Achilles tendon rupture-surgery; Percutaneous Achilles tendon rupture repair ... To fix your torn Achilles tendon, the surgeon will: Make a cut down the back of your heel Make several small cuts rather than one large cut ...

  10. Diaphragmatic hernia repair - slideshow

    Science.gov (United States)

    ... presentations/100014.htm Diaphragmatic hernia repair - series—Normal anatomy To use the sharing ... Overview The chest cavity includes the heart and lungs. The abdominal cavity includes the liver, the stomach, ...

  11. Eye muscle repair - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100062.htm Eye muscle repair - series—Normal anatomy To use the sharing ... the eyeball to the eye socket. The external muscles of the eye are found behind the conjunctiva. ...

  12. Tracheoesophageal fistula repair - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100103.htm Tracheoesophageal fistula repair - series—Normal anatomy To use the sharing ... Editorial team. Related MedlinePlus Health Topics Esophagus Disorders Fistulas Tracheal Disorders A.D.A.M., Inc. is ...

  13. Inguinal hernia repair - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100027.htm Inguinal hernia repair - series—Normal anatomy To use the sharing ... to slide 4 out of 4 Overview A hernia occurs when part of an organ protrudes through ...

  14. Pectus excavatum repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100035.htm Pectus excavatum repair - series—Normal anatomy To use the sharing ... Go to slide 4 out of 4 Overview Pectus excavatum is a deformity of the front of the ...

  15. Hiatal hernia repair - slideshow

    Science.gov (United States)

    ... presentations/100028.htm Hiatal hernia repair - series—Normal anatomy To use the sharing features on ... Overview The esophagus runs through the diaphragm to the stomach. It functions to carry food from the mouth ...

  16. Repairing ceramic insulating tiles

    Science.gov (United States)

    Dunn, B. R.; Laymance, E. L.

    1980-01-01

    Fused-silica tiles containing large voids or gauges are repaired without adhesives by plug insertion method. Tiles are useful in conduits for high-temperature gases, in furnaces, and in other applications involving heat insulation.

  17. Rotator cuff repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100229.htm Rotator cuff repair - series—Normal anatomy To use the sharing ... to slide 4 out of 4 Overview The rotator cuff is a group of muscles and tendons that ...

  18. Cleft lip repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100010.htm Cleft lip repair - series—Normal anatomy To use the sharing ... abnormal opening in the middle of the upper lip. A cleft palate is an opening in the roof of ...

  19. Grey Repairable System Analysis

    Institute of Scientific and Technical Information of China (English)

    Renkuan Guo; Charles Ernie Love

    2006-01-01

    In this paper, we systematically discuss the basic concepts of grey theory, particularly the grey differential equation and its mathematical foundation, which is essentially unknown in the reliability engineering community. Accordingly,we propose a small-sample based approach to estimate repair improvement effects by partitioning system stopping times into intrinsic functioning times and repair improvement times. An industrial data set is used for illustrative purposes in a stepwise manner.

  20. Emergent cardiopulmonary bypass during pectus excavatum repair

    Directory of Open Access Journals (Sweden)

    Ryan Craner

    2013-01-01

    Full Text Available Pectus excavatum is a chest wall deformity that produces significant cardiopulmonary disability and is typically seen in younger patients. Minimally invasive repair of pectus excavatum or Nuss procedure has become a widely accepted technique for adult and pediatric patients. Although it is carried out through a thoracoscopic approach, the procedure is associated with a number of potential intraoperative and post-operative complications. We present a case of cardiac perforation requiring emergent cardiopulmonary bypass in a 29-year-old male with Marfan syndrome and previous mitral valve repair undergoing a Nuss procedure for pectus excavatum. This case illustrates the importance of vigilance and preparation by the surgeons, anesthesia providers as well as the institution to be prepared with resources to handle the possible complications. This includes available cardiac surgical backup, perfusionist support and adequate blood product availability.

  1. Interparietal hernias after open retromuscular hernia repair.

    Science.gov (United States)

    Carbonell, A M

    2008-12-01

    The retromuscular or sublay repair of ventral hernias, popularized by Rives and Stoppa, requires that a layer of tissue be reapproximated dorsal to the mesh to separate the bowel from the prosthetic. This is the first report of two patients who developed bowel obstruction resulting from interparietal incarceration between the posterior rectus sheath and the prosthetic graft through a defect in this dorsal layer. Both patients underwent open retromuscular hernia repair, one with lightweight polypropylene mesh, the other with human acellular dermal matrix. Postoperatively (day 3 and day 42, respectively), the patients developed signs of bowel obstruction. Computed tomography demonstrated the herniation of the small bowel into the potential space between the prosthesis and the posterior rectus sheath. The first patient underwent successful laparoscopic repair, while the second patient had an open operation to reduce the incarcerated bowel and repair the defect. In the patient convalescing from an uneventful retromuscular hernia repair who develops signs and symptoms of a bowel obstruction, there should be a high index of suspicion that an interparietal hernia may have formed, with the small bowel herniated into the surgically created space between the prosthetic and the posterior rectus sheath.

  2. Preparation of dual-template molecularly imprinted polymer coated stir bar based on computational simulation for detection of fluoroquinolones in meat.

    Science.gov (United States)

    Yang, Kun; Wang, Geng Nan; Liu, Hui Zhi; Liu, Jing; Wang, Jian Ping

    2017-03-01

    In this study, a dual-template molecularly imprinted polymer-coated stir bar capable of recognizing nine fluoroquinolone drugs was prepared. Its recognition abilities for fluoroquinolones and other drugs were studied by using computational simulation method. Results showed that the shape and volume of the imprinted cavities were responsible for the polymer's recognition performance. After optimization of several important parameters, a stir-bar-sorptive-extraction method was developed that was combined with high performance liquid chromatography for determination of the nine drugs in meat. The stir bar showed high enrichment factors (33-47 folds), high capture capacities (4640-4950ng) and high recoveries (>90%) for the nine drugs, and could be reused for thirty times. The limits of detection for the nine drugs were in the range of 0.1-0.3ngg(-1), and the recoveries from the fortified blank meat were in the range of 67.4%-99.0%. Therefore, this method could be used as a simple, rapid and specific tool for routine detection of residual fluoroquinolones in meat. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Detecting and Correcting Speech Repairs

    CERN Document Server

    Heeman, P A; Heeman, Peter; Allen, James

    1994-01-01

    Interactive spoken dialog provides many new challenges for spoken language systems. One of the most critical is the prevalence of speech repairs. This paper presents an algorithm that detects and corrects speech repairs based on finding the repair pattern. The repair pattern is built by finding word matches and word replacements, and identifying fragments and editing terms. Rather than using a set of prebuilt templates, we build the pattern on the fly. In a fair test, our method, when combined with a statistical model to filter possible repairs, was successful at detecting and correcting 80\\% of the repairs, without using prosodic information or a parser.

  4. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    Full Text Available ABSTRACT Objective: The purpose of this video is to present the laparoscopic repair of a VUF in a 42-year-old woman, with gross hematuria, in the immediate postoperative phase following a cesarean delivery. The obstetric team implemented conservative management, including Foley catheter insertion, for 2 weeks. She subsequently developed intermittent hematuria and cystitis. The urology team was consulted 15 days after cesarean delivery. Cystoscopy indicated an ulcerated lesion in the bladder dome of approximately 1.0cm in size. Hysterosalpingography and a pelvic computed tomography scan indicated a fistula. Materials and Methods: Laparoscopic repair was performed 30 days after the cesarean delivery. The patient was placed in the lithotomy position while also in an extreme Trendelenburg position. Pneumoperitoneum was established using a Veress needle in the midline infra-umbilical region, and a primary 11-mm port was inserted. Another 11-mm port was inserted exactly between the left superior iliac spine and the umbilicus. Two other 5-mm ports were established under laparoscopic guidance in the iliac fossa on both sides. The omental adhesions in the pelvis were carefully released and the peritoneum between the bladder and uterus was incised via cautery. Limited cystotomy was performed, and the specific sites of the fistula and the ureteral meatus were identified; thereafter, the posterior bladder wall was adequately mobilized away from the uterus. The uterine rent was then closed using single 3/0Vicryl sutures and two-layer watertight closure of the urinary bladder was achieved by using 3/0Vicryl sutures. An omental flap was mobilized and inserted between the uterus and the urinary bladder, and was fixed using two 3/0Vicryl sutures, followed by tube drain insertion. Results: The operative time was 140 min, whereas the blood loss was 100ml. The patient was discharged 3 days after surgery, and the catheter was removed 12 days after surgery

  5. Augmented Reality for Maintenance and Repair (ARMAR)

    Science.gov (United States)

    2007-08-01

    The purpose of this research, Augmented Reality for Maintenance and Repair (ARMAR), was to research the design and development of experimental... augmented reality systems for maintenance job aiding. The goal was to explore and evaluate the feasibility of developing prototype adaptive augmented ... reality systems that can be used to investigate how real time computer graphics, overlaid on and registered with the actual equipment being maintained, can

  6. Ceramic restoration repair: report of two cases

    Directory of Open Access Journals (Sweden)

    Luís Henrique Araújo Raposo

    2009-04-01

    Full Text Available The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In this paper, two cases are presented, in which fractures occurred in extensive metal-ceramic fixed partial dentures, and their replacement was not possible. Ceramic repair was chosen and the sequences of treatment with and without presence of the ceramic fragment are also discussed. The cases illustrate that, in some situations, fractured metal-ceramic partial dentures can be successfully repaired when prosthetic replacement is not a choice. Prosthodontists must use alternatives that allow a reliable repair to extensive metal-ceramic fixed partial dentures. Surface preparation of the ceramic with hydrofluoric acid in conjunction with a silane coupling agent is essential for a predictable bonding of composite resin. The repair performed with composite resin is an esthetic and functional alternative when extensive fixed partial dentures cannot be replaced.

  7. Transient cortical blindness after thoracic endovascular aneurysm repair.

    Science.gov (United States)

    Vallabhaneni, Raghuveer; Jim, Jeffrey; Derdeyn, Colin P; Sanchez, Luis A

    2011-05-01

    We report a patient who presented with transient cortical blindness 12 hours after completion of a thoracic endovascular aneurysm repair. Computed tomography of the brain demonstrated no acute findings. The patient's symptoms resolved spontaneously after 72 hours. To our knowledge, this is the first report of transient cortical blindness after endovascular aortic aneurysm repair. This is an uncommon diagnosis that is important to recognize in a modern vascular surgery practice.

  8. Groin hernia repair in young males: mesh or sutured repair?

    DEFF Research Database (Denmark)

    Bisgaard, T; Bay-Nielsen, M; Kehlet, H

    2010-01-01

    Large-scale data for the optimal inguinal hernia repair in younger men with an indirect hernia is not available. We analysed nationwide data for risk of reoperation in younger men after a primary repair using a Lichtenstein operation or a conventional non-mesh hernia repair....

  9. Cleft lip and palate repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002979.htm Cleft lip and palate repair To use the sharing features on this page, please enable JavaScript. Cleft lip and cleft palate repair is surgery to fix birth defects ...

  10. Abdominal aortic aneurysm repair - open

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007392.htm Abdominal aortic aneurysm repair - open To use the sharing features on this page, please enable JavaScript. Open abdominal aortic aneurysm repair is surgery to fix a widened part ...

  11. Nanomaterials promise better bone repair

    OpenAIRE

    Qifei Wang; Jianhua Yan; Junlin Yang; Bingyun Li

    2016-01-01

    Nanomaterials mimicking the nano-features of bones and offering unique smart functions are promising for better bone fracture repair. This review provides an overview of the current state-of-the-art research in developing and using nanomaterials for better bone fracture repair. This review begins with a brief introduction of bone fracture repair processes, then discusses the importance of vascularization, the role of growth factors in bone fracture repair, and the failure of bone fracture rep...

  12. Laparoscopic repair of femoral hernia

    OpenAIRE

    Yang, Xue-Fei; Liu, Jia-Lin

    2016-01-01

    Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. Femoral hernia could be repaired through the laparoscopic procedures for inguinal hernia. These procedures have clear anatomic view in the operation and preoperatively undiagnosed femoral hernia could be confirmed and treated. Lower recurrence ratio was reported in laparoscopic procedures compared with open procedures for repair of femoral hernia. The technical details of laparoscopic repair of femoral hernia, ...

  13. Aircraft Propeller Hub Repair

    Energy Technology Data Exchange (ETDEWEB)

    Muth, Thomas R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peter, William H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-02-13

    The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spray coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.

  14. 以修复为中心的简易种植模板指导下三种备洞方法的精度比较%Comparison of precision among three methods of cavity preparation directed by simple template of dental implant centered on repair

    Institute of Scientific and Technical Information of China (English)

    夏蕊; 戎志静; 丁明会; 崔晓光; 李枢安; 韩克难

    2016-01-01

    Objective To analyze and compare the precision among three methods of cavity preparation. Methods The dental im⁃plant on the resin patterns based on the bilateral posterior teeth loss was located by employing the simple template of dental implant cen⁃tered on repair. Then the traditional method of preparing cavity by using twist drill step by step, the Brånemark method of cavity prepa⁃ration and the method of preparing cavity by using multistep drill separately were applied to simulate an external cavity preparation for implant on the epoxy patterns. Lastly, the angle and deviation value between plant holes and templates after applying three methods were measured. Results The deviation value existed in all the methods, among which the traditional method of preparing cavity by u⁃sing twist drill step by step showed the most significant one (7.06°±0.37°), followed by the method of preparing cavity by using multi⁃step drill (4.84°±0.75°) and then the Brånemark method of cavity preparation (2.68°±0.77°). Conclusion Directed by simple tem⁃plate of dental implant centered on repair, Brånemark method demonstrates the highest precision, so it is the most suitable method of performing the operation with template.%目的:分析比较3种种植备洞方法的精度。方法利用以修复为中心的简易种植模板在双侧后牙缺失的树脂模型上进行种植定位,分别用传统麻花钻逐级备洞法、Brånemark备洞法和阶梯式钻逐级备洞法对环氧树脂模型进行体外模拟种植备洞,最后测量三种方法备洞后种植窝与模板植入道之间的角度及偏差值。结果不同备洞方法均存在一定偏差值,其中传统麻花钻备洞法的偏差最大(7.06°±0.37°),阶梯钻备洞法次之(4.84°±0.75°),Brånemark备洞法最小(2.68°±0.77°)。结论在以修复为中心的简易种植模板引导下,Brånemark备洞法精度最高,最适

  15. The computed cranial focal point

    NARCIS (Netherlands)

    Jong, G.A. de; Maal, T.J.J.; Delye, H.

    2015-01-01

    INTRODUCTION: Stereophotogrammetry is a radiation-free method for monitoring skull development after craniosynostosis repair. Lack of clear fixed reference points complicate longitudinal comparison of 3D photographs. Therefore we developed the 'computed cranial focal point' (CCFP). METHODS: The CCFP

  16. Repair of Pd/α-Al2O3 composite membrane with defects

    Institute of Scientific and Technical Information of China (English)

    李安武; 熊国兴

    1999-01-01

    A palladium composite membrane with a large number of defects was repaired using the electroless plating combined with the technique of osmosis. The loose structure of palladium film prepared by the conventional electroless plating was densified. Defects were repaired. Hydrogen selectivity was thus significantly increased without significantly increasing palladium film thickness and reducing hydrogen permeability.

  17. Poly(lactic-co-glycolic acid)/tricalcium phosphate scaffolds prepared by rapid prototyping technology for the repair of radial defects in rabbits%快速成型聚乳酸-聚羟乙酸/磷酸三钙支架修复兔桡骨缺损

    Institute of Scientific and Technical Information of China (English)

    孙梁; 熊卓

    2011-01-01

    背景:理想的骨修复材料除必须具有生物相容性、可吸收性、利于血管化及迅速被新生组织替代的孔隙率,还需要有与骨组织相似三维结构.目的:检验快速成型工艺制作的聚乳酸-聚羟乙酸/磷酸三钙支架复合骨形态发生蛋白修复兔桡骨缺损的效果.方法:将乳酸乙醇酸共聚物溶于1,4-二氧六环中并混合粉末状磷酸三钙制备成液态的浆料,放入生物材料快速成形机TissFormTM制备出直径5 mm,长15 mm的圆柱形人工骨载体材料.按每个材料15 mg的标准,采用预湿、负压复合骨形态发生蛋白、冻干3步处理,制备出活性人工骨材料.健康新西兰大白兔20只,制备右前肢桡骨中上段15 mm骨缺损模型,实验组和对照组分别植入复合骨形态发生蛋白的活性人工骨和未复合骨形态发生蛋白的单纯支架.通过影像学、组织学、材料降解及骨密度评价修复兔桡骨缺损的效果.结果与结论:12周时实验组骨缺损愈合,新生骨痂连接缺损断端并塑形,支架材料近于完全降解,各检测指标与对照组比较差异均有显著性意义,对照组骨缺损内未见新骨形成.结果表明复合骨形态发生蛋白的聚乳酸-聚羟乙酸/磷酸三钙支架可以很好的修复兔15 mm骨缺损,且降解速度与成骨速度匹配良好.%BACKGROUND:The ideal bone repair materials must be biocompatible and absorbable, have the porosity that is conducive to the vascularization and rapidly replaced by new tissue, as well as a three-dimensional structu re similar to bone tissue.OBJECTIVE:To test the effect of poly(lactic-co-glycolic acid )/tricalcium phosphate (PLGA/TCP) scaffolds prepared by rapid prototyping technology loaded with bone morphogenetic protein in the repair of radial defect in rabbits.METHODS:The lactic acid/glycolic acid copolymer dissolved in 1,4-dioxane and mixed with calcium phosphate powder to prepare a liquid slurry, then placing into a biomaterial rapid

  18. Nanomaterials promise better bone repair

    Directory of Open Access Journals (Sweden)

    Qifei Wang

    2016-10-01

    Full Text Available Nanomaterials mimicking the nano-features of bones and offering unique smart functions are promising for better bone fracture repair. This review provides an overview of the current state-of-the-art research in developing and using nanomaterials for better bone fracture repair. This review begins with a brief introduction of bone fracture repair processes, then discusses the importance of vascularization, the role of growth factors in bone fracture repair, and the failure of bone fracture repair. Next, the review discusses the applications of nanomaterials for bone fracture repair, with a focus on the recent breakthroughs such as nanomaterials leading to precise immobilization of growth factors at the molecular level, promoting vascularization without the use of growth factors, and re-loading therapeutic agents after implantation. The review concludes with perspectives on challenges and future directions for developing nanomaterials for improved bone fracture repair.

  19. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Nayeemuddin, M. [Department of Interventional Radiology, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom); Pherwani, A.D. [Department of Vascular Surgery, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom); Asquith, J.R., E-mail: john.asquith@uhns.nhs.uk [Department of Interventional Radiology, City General Hospital, University Hospital of North Staffordshire NHS Trust, Stoke-On-Trent (United Kingdom)

    2012-08-15

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  20. Analog and hybrid computing

    CERN Document Server

    Hyndman, D E

    2013-01-01

    Analog and Hybrid Computing focuses on the operations of analog and hybrid computers. The book first outlines the history of computing devices that influenced the creation of analog and digital computers. The types of problems to be solved on computers, computing systems, and digital computers are discussed. The text looks at the theory and operation of electronic analog computers, including linear and non-linear computing units and use of analog computers as operational amplifiers. The monograph examines the preparation of problems to be deciphered on computers. Flow diagrams, methods of ampl

  1. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.

    Science.gov (United States)

    Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M

    2015-10-01

    Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered

  2. Minimal preparation computed tomography instead of barium enema/colonoscopy for suspected colon cancer in frail elderly patients: an outcome analysis study

    Energy Technology Data Exchange (ETDEWEB)

    Kealey, S.M.; Dodd, J.D.; MacEneaney, P.M.; Gibney, R.G.; Malone, D.E. E-mail: d.malone@st-vincents.ie

    2004-01-01

    AIM: To evaluate the efficacy of minimal preparation computed tomography (MPCT) in diagnosing clinically significant colonic tumours in frail, elderly patients. MATERIALS AND METHODS: A prospective study was performed in a group of consecutively referred, frail, elderly patients with symptoms or signs of anaemia, pain, rectal bleeding or weight loss. The MPCT protocol consisted of 1.5 l Gastrografin 1% diluted with sterile water administered during the 48 h before the procedure with no bowel preparation or administration of intravenous contrast medium. Eight millimetre contiguous scans through the abdomen and pelvis were performed. The scans were double-reported by two gastrointestinal radiologists as showing definite (>90% certain), probable (50-90% certain), possible (<50% certain) neoplasm or normal. Where observers disagreed the more pessimistic of the two reports was accepted. The gold standard was clinical outcome at 1 year with positive end-points defined as (1) histological confirmation of CRC, (2) clinical presentation consistent with CRC without histological confirmation if the patient was too unwell for biopsy/surgery, and (3) death directly attributable to colorectal carcinoma (CRC) with/without post-mortem confirmation. Negative end-points were defined as patients with no clinical, radiological or post-mortem findings of CRC. Patients were followed for 1 year or until one of the above end-points were met. RESULTS: Seventy-two patients were included (mean age 81; range 62-93). One-year follow-up was completed in 94.4% (n=68). Mortality from all causes was 33% (n=24). Five histologically proven tumours were diagnosed with CT and there were two probable false-negatives. Results were analysed twice: assuming all CT lesions test positive and considering 'possible' lesions test negative [brackets] (95% confidence intervals): sensitivity 0.88 (0.47-1.0) [0.75 (0.35-0.97)], specificity 0.47 (0.34-0.6) [0.87 (0.75-0.94)], positive predictive value 0

  3. Non-intubated laparoscopic repair of giant Morgagni’s hernia for a young man

    Science.gov (United States)

    Zhang, Miao; Wang, Heng; Liu, Dong; Pan, Xuefeng; Wu, Wenbin; Hu, Zhengqun

    2016-01-01

    An asymptomatic patient was admitted as his chest photograph and computed tomography scans showed a giant Morgagni’s hernia (MH). And it was repaired by laparoscopic approach under epidural anesthesia without endotracheal intubation. The hernia content of omentum was repositioned back into the abdominal cavity, and the diaphragmatic defect was repaired with composite mesh. Which indicated that non-intubated laparoscopic mesh repair via epidural anesthesia is reliable and satisfactory for MH. PMID:27621903

  4. Lubrication System. Teacher's Guide. Small Engine Repair Series. First Edition.

    Science.gov (United States)

    Hill, Pamela

    This teacher's guide accompanies three student manuals and together with them comprises an instructional package on the lubrication system in the Small Engine Repair Series for handicapped/special needs students. The first section, "Notes to the Instructor," covers equipment needs, preparation before teaching the instructional package,…

  5. Computer-aided synthesis of repairs of buildings and the engineering infrastructure Автоматизация синтеза ремонтных работ зданий и инженерной инфраструктуры

    Directory of Open Access Journals (Sweden)

    Volkov Andrey Anatol’evich

    2013-03-01

    Full Text Available The authors present a decision making algorithm applicable in the event of an emergency involving structural elements of a building, as well as the algorithm of synthesis of repair plans (emergency and scheduled repairs consisting in redistribution of emergency repairs over regular repairs.In the event of an accident, a structural element of a building is damaged. An expert compiles a plan of emergency repairs, according to the previously described algorithm, or using PRR CAD software. The proposed algorithm is employed to analyze the plan of emergency repairs and to reconcile it with a plan of scheduled repairs. If the decision is made to conduct emergency repairs within scheduled repairs by means of their synthesis, emergency repairs are redistributed over scheduled repairs. The algorithm of synthesis of plans of repair works is to help the expert distribute emergency repair works over scheduled repair works, or to save material, human and other resources. Implementation of algorithms in a cluster of buildings and structures requires substantial technological resources. Cloud computing technologies can serve as a platform for the implementation of the proposed solutions.Представлен алгоритм принятия решений в случае возникновения аварийной ситуации на конструктивных элементах здания, алгоритм синтеза планов ремонтных работ (аварийных и плановых, заключающийся в перераспределении аварийных ремонтных работ по планам ремонтных работ.

  6. Two- and tridimensional analysis of periapical repair after endodontic surgery.

    Science.gov (United States)

    Tanomaru-FIlho, Mário; Jorge, Érica G; Guerreiro-Tanomaru, Juliane M; Reis, José Mauricio S; Spin-Neto, Rubens; Gonçalves, Marcelo

    2015-01-01

    The aim of this study was to evaluate repair after endodontic surgery using two- and tridimensional imaging methods. Periapical radiographs and cone beam computed tomography (CBCT) were performed before the surgeries and after 48 h (baseline), 4 months, and 8 months. The area (square millimeters) of periapical lesions in CBCT and in radiographs was compared regarding the percentage of repair. In the CBCT, multiple areas were converted to volume. Repeated-measures analyses and paired t tests (α = 0.05) were used to compare the methods. Correlation coefficients were calculated between the periods of evaluation within the CBCT volumetric analysis. Bland-Altman plots were used to compare the methods, based on the 95 % limits of agreement for the difference of the means. Baseline showed a larger lesion volume (192.54 mm(3)) than 4-month (79.79 mm(3)) and 8-month (47.51 mm(3)) periods. No differences were found in the percentage of repair in the first 4 months and after 8 months. The volumetric analysis showed a higher percentage of repair when the first and last 4 months were compared. No differences were found in the percentage of repair by area in the CBCTs. Repair of 73 % was obtained after 8 months. Similar results were observed by the Bland-Altman agreement analyses. The percentage of repair varied after 8 months, when lower values were obtained by volumetric evaluation. Considering the outcome at follow-up periods over 4 months, tridimensional evaluation by CBCT is more capable of determining the absence of periapical bone repair than conventional two-dimensional radiographs. Therefore, the use of CBCT would be suggested only for more complex cases with slower evolution of repair or for the association of factors that make prognosis difficult after surgery.

  7. Anatomical analysis of turgescent and semi-dry resurrection plants: the effect of sample preparation on the sample, resolution, and image quality of X-ray micro-computed tomography (μCT).

    Science.gov (United States)

    Korte, Nikola; Porembski, Stefan

    2011-04-01

    Computer tomography has been used frequently for the 3-D visualization of plant anatomical traits but sample preparation has been widely neglected. Without any preparation smaller (i.e., up to 1 × 1 cm(2) ) turgescent or semi-dry plant samples (especially leaf samples) diminish the image quality of a scan due to gradual water loss and therefore constant movement. A suitable preparation for scans of turgescent and semi-dry plant samples with a high resolution μCT (plant sample efficiently. However, water molecules and vaseline both attenuate the X-ray beam, which decreases the image quality of scans of turgescent or semi-dry plant samples. Therefore, trade-offs between the spatial resolution, sample water content, sample size, and image quality have to be considered: larger samples have to be placed further away from the X-ray tube, which leads to a lower spatial resolution; water and preparation agents attenuate the X-ray beam, causing low-quality images which may be accompanied by motion artifacts compared to a scan of a dry sample, where no preparation is necessary.

  8. Laparoscopic Repair of Morgagni Hernia

    Directory of Open Access Journals (Sweden)

    ilker murat arer

    2015-03-01

    Full Text Available Morgagni hernia is a congenital herniation of abdominal contents into the thoracic cavity through a retrosternal diaphragmatic defect and make up about 1 % - 5 % of all types of congenital diaphragmatic hernias. Surgical repair of Morgagni hernias is usually indicated when patients are symptomatic and have a high risk of strangulation or incarceration of the contained viscera. 71-year-old male patient admitted to emergency department with a 2-day history of abdominal pain, vomiting and obstipation. Laparoscopic repair for Morgagni hernia was performed. Laparoscopic repair for Morgagni hernia with mesh repair is secure, satisfactory and easily performed. [Cukurova Med J 2015; 40(Suppl 1: 71-74

  9. 2-(Dimethylaminoethyl Methacrylate/(2-Hydroxyethyl Methacrylate/α-Tricalcium Phosphate Cryogels for Bone Repair, Preparation and Evaluation of the Biological Response of Human Trabecular Bone-Derived Cells and Mesenchymal Stem Cells

    Directory of Open Access Journals (Sweden)

    Tiago Volkmer

    2014-09-01

    Full Text Available The aim of this work is to evaluate the potential of cryogels to be used as scaffolds in tissue engineering. Scaffolds based on the α-tricalcium phosphate reinforced PDMAEMA (Poly(dimethyl aminoethyl methacrylate/PHEMA (poly(hydroxyethyl methacrylate system were prepared and human trabecular bone-derived cells (HTBs and bone marrow derived-mesenchymal stem cells (BM-MSCs cultured on them. Several features, such as porosity, pore shape, molecular weight between crosslinks and mesh size, are studied. The most suitable PDMAEMA/PHEMA ratio for cell proliferation has been assessed and the viability, adhesion, proliferation and expression of osteoblastic biochemical markers are evaluated. The PDMAEMA/PHEMA ratio influences the scaffolds porosity. Values between 53% ± 5.7% for a greater content in PHEMA and 75% ± 5.5% for a greater content in PDMAEMA have been obtained. The polymer ratio also modifies the pore shape. A greater content in PDMAEMA leads also to bigger network mesh size. Each of the compositions were non-cytotoxic, the seeded cells remained viable for both BM-MSCs and HTBs. Thus, and based on the structural analysis, specimens with a greater content in PDMAEMA seem to provide a better structural environment for their use as scaffolds for tissue engineering. The α-tricalcium phosphate incorporation into the composition seems to favor the expression of the osteogenic phenotype.

  10. Combinatorial Reliability and Repair

    Science.gov (United States)

    1992-07-01

    Press, Oxford, 1987. [2] G. Gordon and L. Traldi, Generalized activities and the Tutte polynomial , Discrete Math. 85 (1990), 167-176. [3] A. B. Huseby, A...particular, Satyanarayana and Tindell introduced a notion of (K,j)-domination in their study of a K-terminal version of the chromatic polynomial [6], and it...G)) graphs. He also intends to look into the properties of the polynomial that gives the expected number of needed repairs of a K-terminal network

  11. Mammalian mismatch repair

    DEFF Research Database (Denmark)

    Pena Diaz, Javier; Jiricny, Josef

    2012-01-01

    A considerable surge of interest in the mismatch repair (MMR) system has been brought about by the discovery of a link between Lynch syndrome, an inherited predisposition to cancer of the colon and other organs, and malfunction of this key DNA metabolic pathway. This review focuses on recent...... advances in our understanding of the molecular mechanisms of canonical MMR, which improves replication fidelity by removing misincorporated nucleotides from the nascent DNA strand. We also discuss the involvement of MMR proteins in two other processes: trinucleotide repeat expansion and antibody maturation...

  12. DNA replication, repair, and repair tests. [Rat; human leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, B.

    1980-09-01

    The rate of inhibition and recovery of DNA synthesis can be used in a rapid assay system to detect genotoxic potentials of chemicals. Also, the observation that an agent stimulates DNA repair in a test system indicates its ability to cause damage in DNA. Different experimental approaches to the study of repair synthesis are discussed.

  13. Simulación Computacional del Procedimiento de Soldadura en Servicio empleado en la Reparación Estructural de un Gasoducto Computational Simulation of In-Service Welding Procedure used in the Structural Repair of a Gas Pipeline

    Directory of Open Access Journals (Sweden)

    Héctor C Sanzi

    2012-01-01

    Full Text Available En este trabajo se presenta un análisis de integridad estructural del proceso de reparación de un gasoducto a partir de un modelo simplificado bidimensional usando elementos finitos. Se evalúan las tensiones residuales de origen térmico, producto del procedimiento de soldadura, considerando que se realiza con el gasoducto circulando fluido, es decir con presión aplicada. Los gasoductos que operan en Argentina son inspeccionados periódicamente de acuerdo a prácticas recomendadas por las normas del Instituto Americano del Petróleo (API y a especificaciones, criterios y experiencias propias desarrolladas por cada planta. El modelado que se presenta permite determinar las zonas debilitadas por corrosión o por diferentes tipos de defectos o fisuras. Esto permite planificar y encausar una reparación localizada con un margen de seguridad adecuado.In this paper, an analysis of structural integrity to the repair of a gas pipeline is presented. The study is based on a simplified two-dimensional finite elements model. The residual stresses of thermal origin caused by the welding process are evaluated considering the pipeline flowing fluid and the pressure exerted by the fluid. Pipelines in Argentina are periodically inspected following the standards of the American Petroleum Institute (API and specifications, criteria and experiences developed by each plant. The modeling allows determining weakened areas caused by corrosion or by different types of defects or cracks. This allows planning and prosecuting a localized repair within acceptable safety margins.

  14. Biologics for tendon repair.

    Science.gov (United States)

    Docheva, Denitsa; Müller, Sebastian A; Majewski, Martin; Evans, Christopher H

    2015-04-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately, our understanding of tendon biology lags far behind that of other musculoskeletal tissues, thus impeding the development of new treatment options for tendon conditions. Hence, in this review, after introducing the clinical significance of tendon diseases and the present understanding of tendon biology, we describe and critically assess the current strategies for enhancing tendon repair by biological means. These consist mainly of applying growth factors, stem cells, natural biomaterials and genes, alone or in combination, to the site of tendon damage. A deeper understanding of how tendon tissue and cells operate, combined with practical applications of modern molecular and cellular tools could provide the long awaited breakthrough in designing effective tendon-specific therapeutics and overall improvement of tendon disease management.

  15. Computer-Assisted Sperm Analysis (CASA) parameters and their evolution during preparation as predictors of pregnancy in intrauterine insemination with frozen-thawed donor semen cycles.

    Science.gov (United States)

    Fréour, Thomas; Jean, Miguel; Mirallié, Sophie; Dubourdieu, Sophie; Barrière, Paul

    2010-04-01

    To study the potential of CASA parameters in frozen-thawed donor semen before and after preparation on silica gradient as predictors of pregnancy in IUI with donor semen cycles. CASA parameters were measured in thawed donor semen before and after preparation on a silica gradient in 132 couples undergoing 168 IUI cycles with donor semen. The evolution of these parameters throughout this process was calculated. The relationship with cycle outcome was then studied. Clinical pregnancy rate was 18.4% per cycle. CASA parameters on donor semen before or after preparation were not significantly different between pregnancy and failure groups. However, amplitude of lateral head displacement (ALH) of spermatozoa improved in all cycles where pregnancy occurred, thus predicting pregnancy with a sensitivity of 100% and a specificity of 20%. Even if CASA parameters do not seem to predict pregnancy in IUI with donor semen cycles, their evolution during the preparation process should be evaluated, especially for ALH. However, the link between ALH improvement during preparation process and pregnancy remains to be explored. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  16. ''In-house'' pharmacological management for computed tomography coronary angiography: heart rate reduction, timing and safety of different drugs used during patient preparation

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Tedeschi, Carlo; Seitun, Sara; Ruffini, Livia; Aldrovandi, Annachiara [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Palumbo, Alessandro A.; Martini, Chiara [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Tarantini, Giuseppe [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); University of Padua, Department of Cardiology, Padua (Italy); Weustink, Annick C.; Meijboom, Willem B.; Mollet, Nico R.; Krestin, Gabriel P.; Feyter, Pim J. de [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Cademartiri, Filippo [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Azienda Ospedaliero-Universitaria - Parma, Department of Radiology c/o Piastra Tecnica - Piano 0, Parma (Italy)

    2009-12-15

    We retrospectively evaluated the effect, timing and safety of different pharmacological strategies during 64-slice CT coronary angiography (CT-CA). From the institutional database of CT-CA we enrolled 560 consecutive patients with suspected coronary artery disease. The type of drug preparation (group 1 = no treatment; group 2 = oral metoprolol; group 3 = other; group 4 = intravenous (IV) atenolol; group 5 = IV atenolol + nitrates; NR = non-responders), timing, and adverse effects were recorded. Heart rate (HR) during different preparation phases was recorded. Four adverse effects were recorded, none of which was attributable to pharmacological treatment. In all groups, except group 1, the HR on arrival was significantly reduced by the pharmacological treatment (p < 0.01). Group 4 showed the best (-16 {+-} 8 bpm) HR reduction. There was no significant effect on HR due to nitrates (p = 0.49), while a slight increase due to contrast material was noted (p < 0.05). Average time required for preparation was 44 {+-} 25 min. Groups 4 and 5 showed the most effective timing (8 {+-} 9 min and 8 {+-} 8 min, respectively; p < 0.01). Pharmacological preparation in patients undergoing CT-CA is safe and effective. Best results in terms of HR reduction and fast preparation are obtained with IV administration of beta-blockers. (orig.)

  17. Evaluation of different rotary devices on bone repair in rabbits

    OpenAIRE

    Ribeiro Junior, Paulo Domingos; Barleto, Christiane Vespasiano; Ribeiro,Daniel Araki; Matsumoto,Mariza Akemi

    2007-01-01

    In oral surgery, the quality of bone repair may be influenced by several factors that can increase the morbidity of the procedure. The type of equipment used for ostectomy can directly affect bone healing. The aim of this study was to evaluate bone repair of mandible bone defects prepared in rabbits using three different rotary devices. Fifteen New Zealand rabbits were randomly assigned to 3 groups (n=5) according to type of rotary device used to create bone defects: I - pneumatic low-speed r...

  18. Biomarkers of oxidative damage to DNA and repair

    DEFF Research Database (Denmark)

    Loft, Steffen; Høgh Danielsen, Pernille; Mikkelsen, Lone

    2008-01-01

    Oxidative-stress-induced damage to DNA includes a multitude of lesions, many of which are mutagenic and have multiple roles in cancer and aging. Many lesions have been characterized by MS-based methods after extraction and digestion of DNA. These preparation steps may cause spurious base oxidation...... DNA glycosylase 1), responsible for repair of 8-oxodG, by genotyping. Products of repair in DNA or the nucleotide pool, such as 8-oxodG, excreted into the urine can be assessed by MS-based methods and generally reflects the rate of damage. Experimental and population-based studies indicate that many...

  19. MRI-based Assessment of Endovascular Abdominal Aortic Aneurysm Repair

    NARCIS (Netherlands)

    Laan, M.J. van der

    2007-01-01

    Imaging techniques play a key role in the Endovascular Abdominal Aortic Aneurysm Repair (EVAR) follow-up. The most important parameters monitored after EVAR are the aneurysm size and the presence of endoleaks. Currently, computed tomographic angiography (CTA) is the most commonly used imaging modali

  20. Radiologic classification of superior canal dehiscence : Implications for surgical repair

    NARCIS (Netherlands)

    Lookabaugh, Sarah; Kelly, Hillary R.; Carter, Margaret S.; Niesten, Marlien E F; McKenna, Michael J.; Curtin, Hugh; Lee, Daniel J.

    2015-01-01

    Objective: Surgical access to repair a superior canal dehiscence (SCD) is influenced by the location of the bony defect and its relationship to surrounding tegmen topography as seen on computed tomography. There are currently no agreed-upon methods of characterizing these radiologic findings. We

  1. The Relevance of Repair for Self Explicating Artifacts.

    Science.gov (United States)

    Raudaskoski, Pirkko

    An in-progress interdisciplinary research effort, Conversation Analytic (CA) and Human-Computer Interaction (HCI) study, is reported. A conversation analytic approach to repair and self-explication is taken that covers both human studies and artificial intelligence. The term "human" is used here in place of "linguistic." Three…

  2. TIBIAL LANDMARKS IN ACL ANATOMIC REPAIR

    Directory of Open Access Journals (Sweden)

    M. V. Demesсhenko

    2016-01-01

    Full Text Available Purpose: to identify anatomical landmarks on tibial articular surface to serve as reference in preparing tibial canal with respect to the center of ACL footprint during single bundle arthroscopic repair.Materials and methods. Twelve frozen knee joint specimens and 68 unpaired macerated human tibia were studied using anatomical, morphometric, statistical methods as well as graphic simulation.Results. Center of the tibial ACL footprint was located 13,1±1,7 mm anteriorly from posterior border of intercondylar eminence, at 1/3 of the distance along the line connecting apexes of internal and external tubercles and 6,1±0,5 mm anteriorly along the perpendicular raised to this point.Conclusion. Internal and external tubercles, as well as posterior border of intercondylar eminence can be considered as anatomical references to determine the center of the tibial ACL footprint and to prepare bone canals for anatomic ligament repair.

  3. Preparation and mechanical properties of microcapsule made of self-repairing composite materials%自修复微胶囊复合材料的制备及力学性能研究

    Institute of Scientific and Technical Information of China (English)

    朱孟花; 齐晶瑶; 李欣

    2011-01-01

    To improve the healing performance and increase the service life of the polymer matrix composites,microcapsules with urea formaldehyde resin as wall material and dicyclopentadiene as core material were prepared by in-situ polymerization method.The effect of the dosage of urea,formaldehyde and emulsifier was investigated.By optimizing the conditions,the microcapsules with compact surface were dispersed well in an epoxy matrix for using in the self-healing system.The morphology and shell thickness of microcapsules were characterized using scanning electron microscopy,and the chemical structure of the microcapsules was confirmed by fourier transform infrared spectroscopy.Mechanical properties of the self-healing polymeric materials were measured by tensile test and finite element method analysis.The results show that the microcapsules had compact structure with proper molor ratio of urea to formaldehyde(1∶ 2) and concentration of emulsifiers(0.5%).Healing was triggered by crack propagation through the microcapsules,which then initiated polymerization and healing of the crack inside the composites.%为了提高树脂基复合材料的使用寿命,以脲醛树脂为壁材,双环戊二烯为囊芯,通过原位聚合法制备了内含修复液的微胶囊,探讨了反应过程中脲醛量比及乳化剂用量等对微胶囊表面形貌和结构的影响.通过优化工艺条件制备出表面致密的微胶囊,并将微胶囊埋植在环氧树脂基体中制备复合材料.采用扫描电镜对胶囊进行形貌表征,运用快速傅里叶变换红外光谱对其化学结构进行表征.通过拉伸试验和有限元分析对自修复材料的断裂力学性能进行了研究.研究表明:当尿素、甲醛的物质的量比为1∶2,乳化剂的用量为0.5%,所制备的微胶囊表面致密;修复反应可以在复合材料内部发生.

  4. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  5. Preparation and biocompatibility of chitosan-collagen corneal repair materials%壳聚糖-胶原角膜修复材料的制备及生物相容性

    Institute of Scientific and Technical Information of China (English)

    杜倩

    2015-01-01

    BACKGROUND:The colagen and chitosan composite membrane made at a certain percentage can reduce the positive charge of chitosan, improve the adsorption force of chitosan, promote the cel adhesion and growth, migration and proliferation, and enhance the biological properties of chitosan, which has become a very excelent biological material. OBJECTIVE:To prepare chitosan-colagen composite membrane and observe its histocompatibility with corneal stroma layer. METHODS:Chitosan-colagen composite membrane was prepared. Totaly 16 New Zealand rabbits were randomly divided into experimental and control groups. The chitosan-colagen composite membrane was implanted into right eye cornea stroma bag in the experimental group, and the chitosan membrane was implanted into right eye cornea stroma bag in the control group. The slit lamp microscope, anterior segment optical coherence tomography and histological observation were conducted after transplantation. RESULTS AND CONCLUSION: Slit lamp microscope observation results showed that after 8 weeks of transplantation, degradation infiltration was visible in the center of the diaphragm, crease buckling was not obvious in the experimental group; the diaphragm was infiltrated completely and crease buckling was notable in the control group. The anterior segment optical coherence tomography results showed that at the 6thweek after transplantation, the composite membrane boundary was fuzzy, its density was very close to the normal corneal tissue, and the corneal shape recovered to normal in the experimental group. The histological findings showed that after 8 weeks of transplantation, in the experimental group, the membrane surface was degraded a little; biodegradable materials were fused with the corneal stroma; there were a smal amount of inflammatory cels infiltrated on the corneal stroma around the iris. In the control group, the membrane degradation was greater than that of the experimental group; degradable substances intertwined

  6. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  7. The journey of DNA repair

    OpenAIRE

    Saini, Natalie

    2015-01-01

    21 years ago, the DNA Repair Enzyme was declared “Molecule of the Year”. Today, we are celebrating another “year of repair”, with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  8. Nucleotide excision repair in yeast

    NARCIS (Netherlands)

    Eijk, Patrick van

    2012-01-01

    Nucleotide Excision Repair (NER) is a conserved DNA repair pathway capable of removing a broad spectrum of DNA damage. In human cells a defect in NER leads to the disorder Xeroderma pigmentosum (XP). The yeast Saccharomyces cerevisiae is an excellent model organism to study the mechanism of NER. The

  9. REPAIRABLE SYSTEM AVAILABILITY MODEL WITH RESPECT TO LIFE DISTRIBUTION OF SPARE PARTS

    Institute of Scientific and Technical Information of China (English)

    WU Yueming

    2008-01-01

    The failed components of repairable systems are replaced with spare parts that may have different failure distributions from those of the components that have failed. The spare parts may be either the same as new, better than new, or worse than new. This is the reality in maintenance engineering. Repair with better spare parts is defined as "super repair". The failure distributions of the spare parts affect the availability of the components and their systems. A novel model is proposed to describe the availability of repairable systems across their operating time, at the level of their components, on the assumption that the failed components are immediately replaced. The model functions with arbitrary failure distributions of spare parts. It can be used to compute the availability of components and systems not only under perfect and imperfect repair but also under super repair.

  10. Rethinking transcription coupled DNA repair.

    Science.gov (United States)

    Kamarthapu, Venu; Nudler, Evgeny

    2015-04-01

    Nucleotide excision repair (NER) is an evolutionarily conserved, multistep process that can detect a wide variety of DNA lesions. Transcription coupled repair (TCR) is a subpathway of NER that repairs the transcribed DNA strand faster than the rest of the genome. RNA polymerase (RNAP) stalled at DNA lesions mediates the recruitment of NER enzymes to the damage site. In this review we focus on a newly identified bacterial TCR pathway in which the NER enzyme UvrD, in conjunction with NusA, plays a major role in initiating the repair process. We discuss the tradeoff between the new and conventional models of TCR, how and when each pathway operates to repair DNA damage, and the necessity of pervasive transcription in maintaining genome integrity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Reward optimization of a repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Castro, I.T. [Departamento de Matematicas, Facultad de Veterinaria, Universidad de Extremadura, Avenida de la Universidad, s/n. 10071 Caceres (Spain)]. E-mail: inmatorres@unex.es; Perez-Ocon, R. [Departamento de Estadistica e Investigacion Operativa, Facultad de Ciencias, Universidad de Granada, Avenida de Severo Ochoa, s/n. 18071 Granada (Spain)]. E-mail: rperezo@ugr.es

    2006-03-15

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures.

  12. Wound repair in Pocillopora

    Science.gov (United States)

    Rodríguez-Villalobos, Jenny Carolina; Work, Thierry M.; Calderon-Aguileraa, Luis Eduardo

    2016-01-01

    Corals routinely lose tissue due to causes ranging from predation to disease. Tissue healing and regeneration are fundamental to the normal functioning of corals, yet we know little about this process. We described the microscopic morphology of wound repair in Pocillopora damicornis. Tissue was removed by airbrushing fragments from three healthy colonies, and these were monitored daily at the gross and microscopic level for 40 days. Grossly, corals healed by Day 30, but repigmentation was not evident at the end of the study (40 d). On histology, from Day 8 onwards, tissues at the lesion site were microscopically indistinguishable from adjacent normal tissues with evidence of zooxanthellae in gastrodermis. Inflammation was not evident. P. damicornis manifested a unique mode of regeneration involving projections of cell-covered mesoglea from the surface body wall that anastomosed to form gastrovascular canals.

  13. Groin hernia repair

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Aasvang, Eske

    2005-01-01

    The choice of anesthesia for groin hernia repair is between general, regional (epidural or spinal), and local anesthesia. Existing data from large consecutive patient series and randomized studies have shown local anesthesia to be the method of choice because it can be performed by the surgeon......, does not necessarily require an attending anesthesiologist, translates into the shortest recovery (bypassing the postanesthesia care unit), has the lowest cost, and has the lowest postoperative morbidity regarding risk of urinary retention. Spinal anesthesia has no documented benefits for this small...... scientific data to support the choice of anesthesia, large epidemiologic and nationwide information from databases show an undesirable high (about 10-20%) use of spinal anesthesia and low (about 10%) use of local infiltration anesthesia. Surgeons and anesthesiologists should therefore adjust their anesthesia...

  14. 构建聚已内酯/明胶电纺复合支架修复颌骨缺损的研究%Preparation of the compound electrospunpoly (ε-caprolactone)/gelatin fibrous scaffolds: a study of repairing mandible defects

    Institute of Scientific and Technical Information of China (English)

    花蕾; 卜寿山; 曹晓建; 张继生; 庄海; 尹林

    2016-01-01

    目的 观察自主构建的聚已内酯/明胶电纺复合支架生物相容性及对颌骨缺损修复的作用.方法 运用电纺技术和明胶.甲基丙烯酰胺水凝胶制备聚已内酯/明胶复合支架.通过细胞计数试剂盒(CCK-8)检测小鼠前成骨细胞与支架共培养的细胞活性.并在新西兰大白兔颌骨缺损模型中植入电纺复合支架.术后12周对新生骨组织进行微型计算机断层扫描(Micro-CT)扫描,苏木素-伊红(HE)染色与马松(Masson)染色.结果 CCK-8结果显示,在7d时实验组(1.939 3±0.417 4)与对照组(2.457 4 ±0.318 0)的细胞活性差异无统计学意义(P>0.05).通过Micro-CT检测,实验组新生骨密度(0.220±0.253)与新生组织构成比(11.941±3.046)均高于对照组(0.179±0.348、5.809±2.433.P<0.05).组织学研究结果显示,在实验组中未见纤维结缔组织侵入再生区域,复合支架部分降解,支架内层可见片层状新生骨组织.结论 这种聚已内酯/明胶电纺复合支架,具有良好的生物相容性,能有效地维持骨再生空间,促进新骨形成.%Objective To study the cell compatibility of the compound electrospun poly (ε-caprolactone)/gelatin fibrous scaffolds for mandibular defect reconstruction.Methods The compound scaffolds of poly (ε-caprolactone)/gelatin electrospun membranes and gelatin-methacrylamide hydrogel (GelMA) were prepared.Cell counting kit-8 (CCK-8) was used to analyze the cell compatibility of MC3T3-E1 cultured with the scaffold.Then we planted the scaffold into animal model of bone defect of the mandibular body in 6 New Zealand white rabbits.The new bone tissue was subjected to microcomputed tomographic (micro-CT) examination and stained with hematoxylin-eosin (HE) and Masson at 12th week postoperatively.Results The result of CCK-8 assay showed that there was no significance in cell viability between experimental group (1.939 3 ± 0.417 4) and control group (2.457 4 ± 0.318 0).Theexperimental group showed higher

  15. Immediate vs delayed repair bond strength of a nanohybrid resin composite.

    Science.gov (United States)

    El-Askary, Farid S; El-Banna, Ahmed H; van Noort, Richard

    2012-06-01

    To evaluate both the immediate and water-stored repair tensile bond strength (TBS) of a nanohybrid resin composite using different bonding protocols. One hundred sixty half hourglass-shaped slabs were prepared. Eighty half-slabs were wet ground immediately after light curing using high-speed abrasive burs, while the other half-slabs were stored in water for one month (delayed) and then wet ground for repair. Each set of the 80 repaired slabs was split into two groups to be tested for TBS after 24 h or 1 month of water storage. For all repaired slabs, either immediate or delayed, four bonding procedures were used involving wet and dry bonding with a 3-step etch-and-rinse adhesive with or without silane pretreatment. TBS tests were performed at a crosshead speed of 0.5 mm/min. To determine the cohesive strength of the resin composite itself, which served as the reference, additional whole slabs were prepared and tested in tension after a 24-h (n = 10) and a 1-month storage period (n = 10). Failure modes were evaluated using a stereomicroscope at 40X magnification. Three-way ANOVA was run to test the effect of water storage, testing time, bonding protocols, and their interactions on the repair TBS, which was given as a percentage of the reference values. For the immediate repair groups, the repair TBS ranged from 40% to 61.9% after 24-h storage and from 26% to 53.1% after 1-month water storage compared to the TBS of the whole slabs. For the delayed repair group, the repaired TBS ranged from 47.2% to 63.6% for the 24-h repairs and from 32.2% to 44.2% for the test groups stored in water for 1 month. Three-way ANOVA revealed that water storage had no significant effect on the repair TBS (p = 0.619). Both testing time and bonding protocols had a significant effect on the repair TBS (p = 0.001). The interactions between the independent variables (water storage, testing time, and bonding protocols) had no significant effect (p = 0.067). The repair bond strength was

  16. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  17. How to repair an episiotomy.

    Science.gov (United States)

    Steen, Mary; Cummins, Bernie

    2016-02-17

    Rationale and key points Skilful repair of an episiotomy is an important aspect of maternal health care. It is essential that midwives and doctors have the knowledge and skills to undertake this procedure in a safe and effective manner. ▶ An episiotomy should be repaired promptly to reduce blood loss and prevent infection. ▶ Repair of an episiotomy is undertaken in three stages: repair of the vaginal mucosa, repair of the muscle layer and repair of the skin layer. ▶ Adequate pain relief should be provided before suturing. Reflective activity Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. Why a rectal examination is recommended before and following repair of an episiotomy. 2. What you would do to improve your suturing skills. 3. The factors that may prevent or delay an episiotomy from healing. Subscribers can upload their reflective accounts at rcni.com/portfolio .

  18. DNA repair in Chromobacterium violaceum.

    Science.gov (United States)

    Duarte, Fábio Teixeira; Carvalho, Fabíola Marques de; Bezerra e Silva, Uaska; Scortecci, Kátia Castanho; Blaha, Carlos Alfredo Galindo; Agnez-Lima, Lucymara Fassarella; Batistuzzo de Medeiros, Silvia Regina

    2004-03-31

    Chromobacterium violaceum is a Gram-negative beta-proteobacterium that inhabits a variety of ecosystems in tropical and subtropical regions, including the water and banks of the Negro River in the Brazilian Amazon. This bacterium has been the subject of extensive study over the last three decades, due to its biotechnological properties, including the characteristic violacein pigment, which has antimicrobial and anti-tumoral activities. C. violaceum promotes the solubilization of gold in a mercury-free process, and has been used in the synthesis of homopolyesters suitable for the production of biodegradable polymers. The complete genome sequence of this organism has been completed by the Brazilian National Genome Project Consortium. The aim of our group was to study the DNA repair genes in this organism, due to their importance in the maintenance of genomic integrity. We identified DNA repair genes involved in different pathways in C. violaceum through a similarity search against known sequences deposited in databases. The phylogenetic analyses were done using programs of the PHILYP package. This analysis revealed various metabolic pathways, including photoreactivation, base excision repair, nucleotide excision repair, mismatch repair, recombinational repair, and the SOS system. The similarity between the C. violaceum sequences and those of Neisserie miningitidis and Ralstonia solanacearum was greater than that between the C. violaceum and Escherichia coli sequences. The peculiarities found in the C. violaceum genome were the absence of LexA, some horizontal transfer events and a large number of repair genes involved with alkyl and oxidative DNA damage.

  19. The Reinforcement Effect of Nano-Zirconia on the Transverse Strength of Repaired Acrylic Denture Base

    Directory of Open Access Journals (Sweden)

    Mohammed Gad

    2016-01-01

    Full Text Available Objective. The aim of this study was to evaluate the effect of incorporation of glass fiber, zirconia, and nano-zirconia on the transverse strength of repaired denture base. Materials and Methods. Eighty specimens of heat polymerized acrylic resin were prepared and randomly divided into eight groups (n=10: one intact group (control and seven repaired groups. One group was repaired with autopolymerized resin while the other six groups were repaired using autopolymerized resin reinforced with 2 wt% or 5 wt% glass fiber, zirconia, or nano-zirconia particles. A three-point bending test was used to measure the transverse strength. The results were analyzed using SPSS and repeated measure ANOVA and post hoc least significance (LSD test (P≤0.05. Results. Among repaired groups it was found that autopolymerized resin reinforced with 2 or 5 wt% nano-zirconia showed the highest transverse strength (P≤0.05. Repairs with autopolymerized acrylic resin reinforced with 5 wt% zirconia showed the lowest transverse strength value. There was no significant difference between the groups repaired with repair resin without reinforcement, 2 wt% zirconia, and glass fiber reinforced resin. Conclusion. Reinforcing of repair material with nano-zirconia may significantly improve the transverse strength of some fractured denture base polymers.

  20. The Reinforcement Effect of Nano-Zirconia on the Transverse Strength of Repaired Acrylic Denture Base.

    Science.gov (United States)

    Gad, Mohammed; ArRejaie, Aws S; Abdel-Halim, Mohamed Saber; Rahoma, Ahmed

    2016-01-01

    Objective. The aim of this study was to evaluate the effect of incorporation of glass fiber, zirconia, and nano-zirconia on the transverse strength of repaired denture base. Materials and Methods. Eighty specimens of heat polymerized acrylic resin were prepared and randomly divided into eight groups (n = 10): one intact group (control) and seven repaired groups. One group was repaired with autopolymerized resin while the other six groups were repaired using autopolymerized resin reinforced with 2 wt% or 5 wt% glass fiber, zirconia, or nano-zirconia particles. A three-point bending test was used to measure the transverse strength. The results were analyzed using SPSS and repeated measure ANOVA and post hoc least significance (LSD) test (P ≤ 0.05). Results. Among repaired groups it was found that autopolymerized resin reinforced with 2 or 5 wt% nano-zirconia showed the highest transverse strength (P ≤ 0.05). Repairs with autopolymerized acrylic resin reinforced with 5 wt% zirconia showed the lowest transverse strength value. There was no significant difference between the groups repaired with repair resin without reinforcement, 2 wt% zirconia, and glass fiber reinforced resin. Conclusion. Reinforcing of repair material with nano-zirconia may significantly improve the transverse strength of some fractured denture base polymers.

  1. 40 CFR 798.5500 - Differential growth inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA...

    Science.gov (United States)

    2010-07-01

    ... repair proficient and repair deficient bacteria: âBacterial DNA damage or repair tests.â 798.5500 Section... inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA damage or repair tests.” (a... killing or growth inhibition of repair deficient bacteria in a set of repair proficient and deficient...

  2. Bone repair and stem cells.

    Science.gov (United States)

    Ono, Noriaki; Kronenberg, Henry M

    2016-10-01

    Bones are an important component of vertebrates; they grow explosively in early life and maintain their strength throughout life. Bones also possess amazing capabilities to repair-the bone is like new without a scar after complete repair. In recent years, a substantial progress has been made in our understanding on mammalian bone stem cells. Mouse genetic models are powerful tools to understand the cell lineage, giving us better insights into stem cells that regulate bone growth, maintenance and repair. Recent findings about these stem cells raise new questions that require further investigations.

  3. Laparoscopic repair of incisional hernia.

    Science.gov (United States)

    Lau, H; Lee, F; Patil, N G

    2001-09-01

    A 75-year-old man developed an incisional hernia over the upper abdomen following a wedge resection of a gastric stromal tumour in 1996. This is the first published report of a successful repair of an incisional hernia via a laparoscopic intraperitoneal on-lay technique using GORE-TEX DualMesh material in Hong Kong. Compared with conventional open repair of incisional hernia, long incisions and wound tension are avoided using the laparoscopic approach. This translates into a reduced risk of wound-related complications and facilitates recovery. In selected cases, minimally invasive surgery is a safe technique for the repair of incisional hernias.

  4. [Inguinal and femoral hernia repair].

    Science.gov (United States)

    Geissler, B; Anthuber, M

    2011-05-01

    With an incidence of 200,000 new cases per year in Germany, inguinal hernia has a significant socioeconomic impact. The 2009 guidelines from the European Hernia Society established treatment recommendations. Hernia repair is based on reinforcing the posterior wall of the inguinal canal by suture or mesh repair by an anterior or posterior approach. Lightweight mesh reduces recurrence rates and is the treatment of choice even in primary hernias. Laparoscopic hernia repair is associated with specific risks but is superior in postoperative pain and earlier return to work.

  5. Tendon repair augmented with a novel circulating stem cell population.

    Science.gov (United States)

    Daher, Robert J; Chahine, Nadeen O; Razzano, Pasquale; Patwa, Sohum A; Sgaglione, Nicholas J; Grande, Daniel A

    2011-01-01

    Tendon ruptures are common sports-related injuries that are often treated surgically by the use of sutures followed by immobilization. However, tendon repair by standard technique is associated with long healing time and often suboptimal repair. Methods to enhance tendon repair time as well as the quality of repair are currently unmet clinical needs. Our hypothesis is that the introduction of a unique stem cell population at the site of tendon transection would result in an improved rate and quality of repair. Achilles tendons of fifty-one Sprague-Dawley rats were transected and suture-repaired. In half of the rats, a biodegradable scaffold seeded with allogenic circulating stem cells was placed as an onlay to the defect site in addition to the suture repair. The other half was treated with suture alone to serve as the control group. Animals were randomized to a two-, four-, or six-week time group. At the time of necropsy, tendons were harvested and prepared for either biomechanical or histological analysis. Histological slides were evaluated in a blinded fashion with the use of a grading scale. By two weeks, the experimental group demonstrated a significant improvement in repair compared to controls with no failures. Average histological scores of 0.6 and 2.6 were observed for the experimental and control group respectively. The experimental group demonstrated complete bridging of the transection site with parallel collagen fiber arrangement. By four weeks, both groups showed a continuing trend of healing, with the scaffold group exceeding the histological quality of the tissue repaired with suture alone. Biomechanically, the experimental group had a decreasing cross-sectional area with time which was also associated with a significant increase in the ultimate tensile strength of the tendons, reaching 4.2MPa by six weeks. The experimental group also achieved a significantly higher elastic toughness by six weeks and saw an increase in the tensile modulus, reaching

  6. Polymer nanocomposites for high-temperature composite repair

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Xia [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    A novel repair agent for resin-injection repair of advanced high temperature composites was developed and characterized. The repair agent was based on bisphenol E cyanate ester (BECy) and reinforced with alumina nanoparticles. To ensure good dispersion and compatibility with the BECy matrix in nanocomposites, the alumina nanoparticles were functionalized with silanes. The BECy nanocomposites, containing bare and functionalized alumina nanoparticles, were prepared and evaluated for their thermal, mechanical, rheological, and viscoelastic properties. The monomer of BECy has an extremely low viscosity at ambient temperature, which is good for processability. The cured BECy polymer is a highly cross-linked network with excellent thermal mechanical properties, with a high glass transition temperature (Tg) of 270 C and decomposition temperature above 350 C. The incorporation of alumina nanoparticles enhances the mechanical and rheological properties of the BECy nanocomposites. Additionally, the alumina nanoparticles are shown to catalyze the cure of BECy. Characterization of the nanocomposites included dynamic mechanical analysis, differential scanning calorimetry, thermogravimetric analysis, rheological and rheokinetic evaluation, and transmission electron microscopy. The experimental results show that the BECy nanocomposite is a good candidate as repair agent for resin-injection repair applications.

  7. Repair of sciatic nerve defects using tissue engineered nerves*

    Institute of Scientific and Technical Information of China (English)

    Caishun Zhang; Gang Lv

    2013-01-01

    In this study, we constructed tissue-engineered nerves with acel ular nerve al ografts in Sprague-Dawley rats, which were prepared using chemical detergents-enzymatic digestion and mechanical methods, in combination with bone marrow mesenchymal stem cel s of Wistar rats cultured in vitro, to repair 15 mm sciatic bone defects in Wistar rats. At postoperative 12 weeks, electrophysiological detection results showed that the conduction velocity of regenerated nerve after repair with tis-sue-engineered nerves was similar to that after autologous nerve grafting, and was higher than that after repair with acel ular nerve al ografts. Immunohistochemical staining revealed that motor endplates with acetylcholinesterase-positive nerve fibers were orderly arranged in the middle and superior parts of the gastrocnemius muscle;regenerated nerve tracts and sprouted branches were connected with motor endplates, as shown by acetylcholinesterase histochemistry combined with silver staining. The wet weight ratio of the tibialis anterior muscle at the affected contralateral hind limb was similar to the sciatic nerve after repair with autologous nerve grafts, and higher than that after repair with acel ular nerve al ografts. The hind limb motor function at the affected side was significantly improved, indicating that acel ular nerve al ografts combined with bone marrow me-senchymal stem cel bridging could promote functional recovery of rats with sciatic nerve defects.

  8. Does the light source affect the repairability of composite resins?

    Directory of Open Access Journals (Sweden)

    Emel KARAMAN

    2014-08-01

    Full Text Available The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin—Filtek Silorane, Filtek Z550 (3M ESPE, Gradia Direct Anterior (GC, and Aelite Posterior (BISCO—were prepared and light-cured with a QTH light curing unit (LCU. The specimens were aged by thermal cycling and divided into three subgroups according to the light source used—QTH, LED, or PAC (n = 10. They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray. The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  9. Computer simulation for photo damage and self-repair of thymine%胸腺嘧啶紫外损伤与自修复机理的计算机模拟

    Institute of Scientific and Technical Information of China (English)

    舒坤贤; 马静; 袁帅; 豆育升

    2011-01-01

    A semiclassical dynamics simulation study is reported for excitement and deactivation of thymine molecule in order to research photo damage and self-repairs of DNA under UV irradiation. The laser pulse used to simulations is 5.0 eV with fwhm( full width of half maxium) of 50 femtoseconds. The simulation finds that the thymine molecule will be induced to excited state by UV irradiation. The deformations of thymine molecule in excited state maybe result in gene mutation. The non-radiation transition of excited thymine via deformation of C6 atom and H6 atom occurs within ultra-short timescale, lead thymine to its initial planar geometry and avoid UV photo damage. This research will provide theoretical supporting for prevention of skin cancer.%为了研究DNA分子紫外光辐射下光损伤和自修复,采用半经典动力学方法模拟了胸腺嘧啶分子激发与失活过程.模拟脉冲频率为5.0 eV,fwhm=50 fs.模拟发现胸腺嘧啶在紫外辐射下会生成电子激发态,导致分子结构畸变,可能引发突变.由于激发态寿命极短,激发态的胸腺嘧啶分子通过H6原子和C6原子的畸变发生无辐射失活而衰减至基态,恢复其初始的平面结构,从而最大程度地避免了紫外损伤.本研究可为皮肤癌等疾病的预防提供一定的理论支持.

  10. Large myelomeningocele repair

    Directory of Open Access Journals (Sweden)

    Farideh Nejat

    2011-01-01

    Full Text Available Background: Wound closure is accomplished in most cases of myelomeningocele (MMC by undermining of the skin edges surrounding the defect. However, large defects cannot be closed reliably by this simple technique. Due to the technical challenge associated with large MMC, surgeons have devised different methods for repairing large defects. In this paper, we report our experience of managing large defects, which we believe bears a direct relationship to decrease the incidence of wound complications. Materials and Methods: Forty children with large MMCs underwent surgical repair and represent our experience. We recommend using all hairy skin around the defect as a way to decrease the tension on the edges of the wound and the possible subsequent necrosis. It is our experience that vertical incision on one or two flanks parallel to the midline can decrease the tension of the wound. Moreover, ventriculo-peritoneal shunting for children who developed hydrocephalus was performed simultaneously, which constitutes another recommendation for preventing fluid collection and build up of pressure on the wound. Results: Patients in this study were in the age range of 2 days to 8 years. The most common location of MMC was in the thoracolumbar area. All but four patients had severe weakness in lower extremities. We used as much hairy skin around the MMC sac as possible in all cases. Vertical incisions on one or both flanks and simultaneous shunt procedure were performed in 36 patients. We treated children with large MMC defects with acceptable tension-free closure. Nonetheless, three patients developed superficial skin infection and partial wound dehiscence, and they were managed conservatively. Conclusions: We recommend using all hairy skin around the MMC defect for closure of large defects. In cases that were expected to be at a higher risk to develop dehiscence release incisions on one or two flanks towards the fascia were found to be useful. Simultaneous

  11. Teaching of direct composite restoration repair in undergraduate dental schools in the United Kingdom and Ireland.

    Science.gov (United States)

    Blum, I R; Lynch, C D; Wilson, N H F

    2012-02-01

    To investigate aspects of the teaching of restoration repair as a minimally invasive alternative to the replacement of defective direct composite restorations in teaching programmes in undergraduate curricula in dental schools in the United Kingdom and Ireland. An online questionnaire which sought information in relation to the current teaching of composite restoration repair was developed and distributed to the 17 established UK and Irish dental schools with undergraduate teaching programmes in Spring 2010. Completed responses were received from all 17 schools (response rate= 100%). Fifteen schools reported that they included teaching of repair techniques for defective direct composite restorations in their programme. Of the two remaining schools, one indicated that it would introduce teaching of repair techniques during the next five years. The most common indication for a composite repair was that of 'tooth substance preservation' (15 schools). The defects in restorations considered appropriate for repair rather than replacement by the largest number of schools included partial loss of restoration (13 schools) and marginal defects (12 schools). The most commonly taught surface treatment when performing a repair was mechanical roughening of the existing composite with removal of the surface layer (14 schools). Thirteen schools taught etching and the application of an adhesive bonding agent to the prepared surfaces, while the most commonly taught material for completing the repair was a hybrid composite resin (12 schools). Popular finishing implements included diamond finishing instruments (13 schools) and finishing discs (11 schools). Not withstanding reluctance amongst general dental practitioners, the teaching of repair of a defective composite restoration, rather than total restoration replacement, is firmly established within UK and Irish dental school programmes. Repair techniques have clear advantages for patients, not least including a minimally invasive

  12. A Two-Unit Cold Standby Repairable System with One Replaceable Repair Facility and Delay Repair:Some Reliability Problems

    Institute of Scientific and Technical Information of China (English)

    WEI Ying-yuan; TANG Ying-hui

    2004-01-01

    This paper considers a two-unit same cold standby repairable system with a replaceable repair facility and delay repair .The failure time of unit is assumed to follow exponential distribution , and the repair time and delay time of failed unit are assumed to follow arbitrary distributions , whereas the failure and replacement time distributions of the repair facility are exponential and arbitrary . By using the Markov renewal process theory, some primary reliability quantities of the system are obtained.

  13. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15...

  14. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it...

  15. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... successful repair of the leak. (3) Maximum instrument reading measured by Method 21 of 40 CFR part 60... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner...

  16. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    : homologous recombination and non-homologous end-joining. Ataxia telangiectasia and related disorders with defects in these pathways illustrate that such defects can lead to early childhood neurodegeneration. Aging is a risk factor for neurodegeneration and accumulation of oxidative mitochondrial DNA damage......Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...

  17. Early days of DNA repair: discovery of nucleotide excision repair and homology-dependent recombinational repair.

    Science.gov (United States)

    Rupp, W Dean

    2013-12-13

    The discovery of nucleotide excision repair in 1964 showed that DNA could be repaired by a mechanism that removed the damaged section of a strand and replaced it accurately by using the remaining intact strand as the template. This result showed that DNA could be actively metabolized in a process that had no precedent. In 1968, experiments describing postreplication repair, a process dependent on homologous recombination, were reported. The authors of these papers were either at Yale University or had prior Yale connections. Here we recount some of the events leading to these discoveries and consider the impact on further research at Yale and elsewhere.

  18. Construction, repair and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Hinger, R. [Terasen Pipelines, Calgary, AB (Canada); Wong, P. [KC Integrity Corp., Calgary, AB (Canada); Yeomans, M.; Glover, A. [TransCanada PipeLines Ltd., Calgary, AB (Canada)

    2003-07-01

    The presentations by Working Group 4 focused on construction, repair and maintenance of pipelines with particular reference to high-strength steels and their applications for natural gas transmission pipelines. Discussions focused on how technology can be used to provide cost-effective design and construction solutions for long distance pipelines in a manner that does not compromise safety and reliability. The role that carbon plays in increasing the toughness of steel was also discussed. A few fundamental changes in steel production technology and a reduction in carbon content can result in a simultaneous increase in strength and toughness of steels. The cost impact of this technology was summarized. It was concluded that high strength steels offer effective solutions to deliver cost-effective pipelines to transport natural gas from northern basins. This session also presented pipeline routes that transport diluted bitumens from the Athabasca Oil Sands Project and the Muskeg River Mine to upgrader facilities in Alberta. Construction issues included design conservatism, water course crossings, winter construction, winter ditching, and public consultation. Examples of high strength steel pipe applications were also included with reference to experience gained by TransCanada and Corridor Pipeline. tabs., figs.

  19. Laparoscopic repair of postoperative perineal hernia.

    LENUS (Irish Health Repository)

    Ryan, Stephen

    2010-01-01

    Perineal hernias are infrequent complications following abdominoperineal operations. Various approaches have been described for repair of perineal hernias including open transabdominal, transperineal or combined abdominoperineal repairs. The use of laparoscopic transabdominal repair of perineal hernias is not well-described. We present a case report demonstrating the benefits of laparoscopic repair of perineal hernia following previous laparoscopic abdominoperineal resection (APR) using a nonabsorbable mesh to repair the defect. We have demonstrated that the use of laparoscopy with repair of the pelvic floor defect using a non absorbable synthetic mesh offers an excellent alternative with many potential advantages over open transabdominal and transperineal repairs.

  20. Umbilical and epigastric hernia repair.

    Science.gov (United States)

    Muschaweck, Ulrike

    2003-10-01

    The repair of umbilical and epigastric hernias still represents a challenge to surgeons. Although a common and relatively simple procedure, there is no exact protocol today on how the repair should be done. The Mayo technique and its alterations could not stand the test of time: a recurrence rate of 20% and higher is not acceptable for any surgical procedure. Although there is no consensus opinion, one thing is clear: the importance of an anatomic repair without tension and without an artificial enlargement of the defect. In 1987 Lichtenstein reported on 6321 cases of herniorraphy with a tension free repair, and in 1994 Stuart reemphasized that special importance in his editorial in the Lancet. A newer study from Brancato and coworkers in Italy also states the advantage of a tension-free prosthetic repair in 16 patients with epigastric hernia. We have gone even further and recommend a tailored-to-the-patient repair using a customized polypropylene mesh and a one-layer running suture. The advantages should be obvious: no artificial creation of an even bigger than original defect, a completely tension-free repair, and little to no recurrence of the hernia. Our results clearly prove that assumption. Moreover, the procedure is extremely safe and complications are very rare and minor. We conclude that using a mesh plug in a customized tension-free repair of umbilical and epigastric hernia shows many advantages over the commonly used methods. And we finally conclude with the words of Albert Einstein: "The only source of knowledge is experience."

  1. Repair Types, Procedures - Part 1

    Science.gov (United States)

    2010-05-01

    New Jersey, USA. Repair Types, Procedures – Part I RTO-EN-AVT-156 9 - 19 [5] Drieker R, Botello C, MacBeth S, and Grody J, “Aircraft Battle... MacBeth S, and Grody J, “Aircraft Battle Damage Assessment and Repair (ABDAR), Vol. III: Field Test Report,” AFRL-HE-WP-TR-2002-0039, July 2000. [8

  2. Hand function after nerve repair.

    OpenAIRE

    Lundborg, Göran; Rosén, Birgitta

    2007-01-01

    Treatment of injuries to major nerve trunks in the hand and upper extremity remains a major and challenging reconstructive problem. Such injuries may cause long-lasting disabilities in terms of lost fine sensory and motor functions. Nowadays there is no surgical repair technique that can ensure recovery of tactile discrimination in the hand of an adult patient following nerve repair while very young individuals usually regain a complete recovery of functional sensibility. Post-traumatic nerve...

  3. Cobbler's technique for Iridodialysis repair

    Directory of Open Access Journals (Sweden)

    Surinder Singh Pandav

    2016-01-01

    Full Text Available We describe a novel “Cobbler's technique” for iridodialysis repair in the right eye of a patient aged 18 years, with a traumatic iridodialysis secondary to open globe injury with an iron rod. Our technique is simple with easy surgical maneuvers, that is, effective for repairing iridodialysis. The “Cobbler's technique” allows a maximally functional and cosmetic result for iridodialysis.

  4. Rehabilitation after Rotator Cuff Repair.

    Science.gov (United States)

    Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos

    2017-01-01

    Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.

  5. Repairing Learned Knowledge Using Experience

    Science.gov (United States)

    1990-05-01

    It necessar and Identify by’ 6109h nii be) learning precedent-based learning knowledge repair explanation-based learning near - miss groups 20. ABSTRACT...can a program use explanations to repair a recollection, preventing further misapplication? Near - Miss Groups Isolate Suspicious Relations If a metal...pail differs from a porcelain cup only in the position of handle attachment, then we would say that the pail is a near miss . Unfortunately, there are

  6. Base excision repair in sugarcane

    Directory of Open Access Journals (Sweden)

    Agnez-Lima Lucymara F.

    2001-01-01

    Full Text Available DNA damage can be induced by a large number of physical and chemical agents from the environment as well as compounds produced by cellular metabolism. This type of damage can interfere with cellular processes such as replication and transcription, resulting in cell death and/or mutations. The low frequency of mutagenesis in cells is due to the presence of enzymatic pathways which repair damaged DNA. Several DNA repair genes (mainly from bacteria, yeasts and mammals have been cloned and their products characterized. The high conservation, especially in eukaryotes, of the majority of genes related to DNA repair argues for their importance in the maintenance of life on earth. In plants, our understanding of DNA repair pathways is still very poor, the first plant repair genes having only been cloned in 1997 and the mechanisms of their products have not yet been characterized. The objective of our data mining work was to identify genes related to the base excision repair (BER pathway, which are present in the database of the Sugarcane Expressed Sequence Tag (SUCEST Project. This search was performed by tblastn program. We identified sugarcane clusters homologous to the majority of BER proteins used in the analysis and a high degree of conservation was observed. The best results were obtained with BER proteins from Arabidopsis thaliana. For some sugarcane BER genes, the presence of more than one form of mRNA is possible, as shown by the occurrence of more than one homologous EST cluster.

  7. Microcracks repairing technique for gun barrel

    Institute of Scientific and Technical Information of China (English)

    YU Xu-dong; WU Bin; SU Bing; WANG Cheng-tao

    2004-01-01

    When a gun fires the diffusion of chemical species from the propellant gas, such as CO, CO2, H2, H2O and N2, into the hot surface through the microcracks forms reaction products and speeds up the erosion process.Therefore, crack repairing and healing can be a possible measure for protecting against erosion of gun bore. The present study develops a novel nanocomposite with the size of 30 - 150 nm to repair and heal the microcracks so that the propellant gas can be prevented from reacting with the steel. Sample of gun steel 40CrNiMoV plate (10 mm× 10 mm × 2 mm) is prepared and a fishtail crack is generated through a repeated plastic deformation process. The crackrepairing results show that the fishtail crack become shorter and narrower. A new phase is formed, which is found to have the elements, such as Ca, La, from the raw materials of nanocomposite by energy spectrum analysis.

  8. Aging and DNA repair capability. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Tice, R R

    1977-01-01

    A review of the literature on DNA repair processes in relation to aging is presented under the following headings: DNA repair processes; age-related occurrence of unrepaired DNA lesions; DNA repair capability as a function of age; tissue-specific DNA repair capability; acceleration of the aging process by exposure to DNA damaging agents; human genetic syndromes; and longevity and DNA repair processes. (HLW)

  9. Laparoscopic repair of Morgagni′s hernia: An innovative approach

    Directory of Open Access Journals (Sweden)

    Rasik S Shah

    2015-01-01

    Full Text Available Aim: To review our experience of laparoscopic repair of Morgagni′s hernia (MH using transfascial sutures. Materials and Methods: This is a retrospective review of patients presenting to the first author with the diagnosis of MH over a 15-year period. The variables analyzed included demographic data, clinical presentation, and operative details. Results: In all there were five male with a median age of 2 years. They were asymptomatic and MH was detected incidentally by observing an air-filled density in the right cardiophrenic angle on plain X-ray of the chest. Computed tomography (CT confirmed the diagnosis in all patients. All patients underwent laparoscopic repair of MH using transfascial sutures. The average operative time was 75 min. Oral feeding was started 6 h after surgery and patients were discharged on either 3 rd or 4 th postoperative day. Postoperative follow-up X-ray confirmed the intact repair. Conclusions: Laparoscopic repair of MH using transfascial sutures is an easy and effective solution. Multiple horizontal mattress sutures taking full thickness of abdominal wall muscles with the edge of the diaphragm leads to a strong repair. As sutures are tied extracorporeally, the technique is easily reproducible.

  10. Laparoscopic repair of Morgagni's hernia: An innovative approach

    Science.gov (United States)

    Shah, Rasik S.; Sharma, Pradeep Chandra; Bhandarkar, Deepraj S.

    2015-01-01

    Aim: To review our experience of laparoscopic repair of Morgagni's hernia (MH) using transfascial sutures. Materials and Methods: This is a retrospective review of patients presenting to the first author with the diagnosis of MH over a 15-year period. The variables analyzed included demographic data, clinical presentation, and operative details. Results: In all there were five male with a median age of 2 years. They were asymptomatic and MH was detected incidentally by observing an air-filled density in the right cardiophrenic angle on plain X-ray of the chest. Computed tomography (CT) confirmed the diagnosis in all patients. All patients underwent laparoscopic repair of MH using transfascial sutures. The average operative time was 75 min. Oral feeding was started 6 h after surgery and patients were discharged on either 3rd or 4th postoperative day. Postoperative follow-up X-ray confirmed the intact repair. Conclusions: Laparoscopic repair of MH using transfascial sutures is an easy and effective solution. Multiple horizontal mattress sutures taking full thickness of abdominal wall muscles with the edge of the diaphragm leads to a strong repair. As sutures are tied extracorporeally, the technique is easily reproducible. PMID:25829669

  11. The Posterolateral Portal: Optimizing Anchor Placement and Labral Repair at the Inferior Glenoid

    OpenAIRE

    Cvetanovich, Gregory L.; McCormick, Frank; Erickson, Brandon J.; Gupta, Anil K.; Abrams, Geoff D.; Harris, Joshua D.; Romeo, Anthony A.; Bach, Bernard R.; Provencher, Matthew T.

    2013-01-01

    The Bankart lesion is considered the critical lesion in anterior shoulder instability, in which the anteroinferior glenoid labrum separates from the glenoid rim. Technical advances in arthroscopy have ushered in a shift from open to arthroscopic Bankart repair. When one is performing an arthroscopic Bankart repair, proper portal placement is critical for success in labral preparation and anchor placement. Frequently, standard anterior portals are insufficient for inferior glenoid anchor place...

  12. Efficacy of conventional and experimental techniques for denture repair.

    Science.gov (United States)

    Rached, R N; Powers, J M; Del Bel Cury, A A

    2004-11-01

    This study investigated the efficacy of one experimental and three conventional techniques for denture repair. Forty maxillary dentures were constructed in dental stone casts duplicated from an edentulous copper-aluminium maxillary master cast. Two groups of 20 dentures each were prepared with Lucitone 199 (water-bath, 8 h/74 degrees C) or Acron MC (microwave, 3 min/500 W) denture base materials processed in gypsum moulds. The 40 dentures were all separated sagittally in the middle. After that, five dentures of each denture base material were repaired with one of the four following techniques: L (Lucitone 199, water-bath, 8 h/74 degrees C, gypsum mould), A (Acron MC, microwave, 3 min/500 W, gypsum mould), AR (Acron MC/R, autopolymerized, 60 psi/45 degrees C/15 min) and the experimental technique AS (Acron MC, 1 min/500 W + 1 min/0 W + 1 min/500 W, hard silicone mould). The parameters denture accuracy (DA), horizontal (HC) and vertical changes (VC) of the occlusal plane measured the efficacy of the repair techniques. The DA was determined by weighing a film of silicone impression material set in contact to the tissue surface of the denture seated on the metallic master die. For HC, cross-arch measurements were made among reference marks drilled on the teeth 11, 21, 16 and 26. The VC was obtained by calculating the relative differences in height between similar teeth of each semi-arch (pairs 13-23, 14-24, 15-25 e 16-26). For DA, HC and VC, the percentage differences between the percentage means obtained before and after repair were calculated and grouped for comparisons. Analysis of variance (SuperANOVA) and means compared by Tukey-Kramer intervals (0.05) revealed that AR repair had the best percentage difference value for DA [0.5% (P 0.05)]. For HC, there was a statistical difference (P 0.05). Denture accuracy was not affected by the interaction of base material-repair technique; repair with AR technique gave the best adaptation; the interaction of base material-repair

  13. 49 CFR 1242.42 - Administration, repair and maintenance, machinery repair, equipment damaged, dismantling retired...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Administration, repair and maintenance, machinery repair, equipment damaged, dismantling retired property, fringe benefits, other casualties and insurance... maintenance, machinery repair, equipment damaged, dismantling retired property, fringe benefits,...

  14. Evaluation of Adhesive Bond Primers for Repair Bonding of Aluminum

    Science.gov (United States)

    2011-11-02

    3M’s EW 5000 (low-VOC, chromated) – 3M’s EW 5000 AS (low-VOC, nonchromated corrosion inhibitor) • Spray Applied Using Conventional Air Gun – Dry film ...Statement A: Approved for Public Release; Distribution is Unlimited. Mins after Air Dry at Ambient Conditions for 30 Mins Materials and Processes (cont...prebond surface preparation • Used in USAF for rework and preparation of repair doublers – Grit Blast/Sol Gel (GBSG)- - • Al2O3 grit-blast followed by

  15. 计算机辅助构建气管软骨环并行气管前壁缺损修复实验研究%Experimental study on computer-aided construction of tracheal rings for anterior tracheal defect repair

    Institute of Scientific and Technical Information of China (English)

    王晋平; 赵大庆; 罗家胜; 李海立; 郑德育

    2014-01-01

    目的:探讨利用人工材料在计算机辅助下体外构建气管软骨环进行颈段气管缺损修复的可行性。方法用β-磷酸三钙(β-TCP)材料制造出气管环。12只成年杂种犬,雌犬4只,雄犬8只,犬龄约2岁,体质量11~13 kg。随机均分为2组。行气管前壁3~5环全层缺损造模(缺损2 cm ×5 cm),在气管切除部位形成一直径约2 cm、长约5 cm的皮管。实验组利用计算机辅助构建气管软骨环阴模,以β-TCP材料制作的内径约2 cm的2个C形气管软骨环支架置于人工皮管外侧,外侧以肌肉覆盖,逐层缝合关闭术腔。对照组以相同方法行气管前壁全层缺损造模,并形成与实验组相同的人工皮管,但皮管外面不置β-TCP构建的软骨环支架。动物饲养至8周时处死取材,行大体解剖、纤维喉镜、CT及常规组织学检查。结果术后所有动物伤口局部未见明显感染征象。对照组1只皮下严重气肿,当日死亡;大体解剖可见修复部分气管前壁塌陷,管腔狭小;其余动物均存活至8周,术后1周出现气喘,术后2周出现进食呕吐及颈部活动受限;纤维喉镜检查,修复部位气管前壁已出现塌陷,有明显的反常呼吸运动。实验组动物均成活良好,未见上述症状。纤维喉镜检查:重建气道通畅。CT检查:植入物位置良好。组织学检查,支架材料已与周围组织融合为一体,组织已长入支架材料的孔隙中。结论实验应用计算机辅助技术,使修复支架制作达到个体化,β-TCP材料具有良好的生物相容性,且应用计算机辅助技术依个体需要快速塑型,能较好地修复气管缺损。%Objective To explore the feasibility of computer-aided construction of tracheal rings using artificial materials for repairing cervical tracheal defect. Methods β-tricalcium phosphate(β-TCP) material was used to construct tracheal rings. Twelve adult mongrel

  16. In Vitro Comparison of the Bond Strength between Ceramic Repair Systems and Ceramic Materials and Evaluation of the Wettability.

    Science.gov (United States)

    Kocaağaoğlu, Hasan; Manav, Taha; Albayrak, Haydar

    2017-04-01

    When fracture of an all-ceramic restoration occurs, it can be necessary to repair without removing the restoration. Although there are many studies about the repair of metal-ceramic restorations, there are few about all-ceramic restorations. The aim of this study was to evaluate the shear bond strength between ceramic repair systems and esthetic core materials and to evaluate the wettability of all-ceramic core materials. Disk-like specimens (N = 90) made of three dental ceramic infrastructure materials (zirconia ceramic, alumina ceramic, glass ceramic) were polished with silicon carbide paper, prepared for bonding (abrasion with 30 μm diamond rotary cutting instrument). Thirty specimens of each infrastructure were obtained. Each infrastructure group was divided into three subgroups; they were bonded using 3 repair systems: Bisco Intraoral Repair Kit, Cimara & Cimara Zircon Repair System, and Clearfil Repair System. After 1200 thermocycles, shear bond strength was measured in a universal testing machine at a 0.5 mm/min crosshead speed. In addition, the contact angle values of the infrastructures after surface treatments were examined for wettability. Data were analyzed by using ANOVA and Tukey post hoc tests. Although there were no significant differences among the repair systems (p > 0.05) in the glass ceramic and zirconia groups, a significant difference was found among the repair systems in alumina infrastructure (p 0.05); however, a statistically significant difference was found among the repair systems (p < 0.05). No difference was found among the infrastructures and repair systems in terms of contact angle values. Cimara & Cimara Zircon Repair System had higher bond strength values than the other repair systems. Although no difference was found among the infrastructures and repair systems, contact wettability angle was decreased by surface treatments compared with polished surfaces. © 2015 by the American College of Prosthodontists.

  17. PROSPECTIVE STUDY ON DARNING AND LICHTENSTEIN MESH HERNIOPLASTY (LMH IN INGUINAL HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Affin

    2016-01-01

    Full Text Available INTRODUCTION Prospective study on Darning and Lichtenstein Mesh Hernioplasty in Inguinal Hernia Repair is a study of 61 cases of inguinal hernias which were treated by either open Inguinal hernia mesh repair (Lichtenstein or darning repair. The study was conducted with an objective to compare the effectiveness of these procedures and complications if any. 61 cases of inguinal hernia admitted in Yenepoya Medical College Hospital, Mangalore were selected on the basis of the non-probability (prospective sampling method. All patients with uncomplicated direct and indirect hernias treated by darning or mesh repair were included. After preoperative preparation they were randomly chosen for darning or mesh repair. The age/sex incidence, mode of presentation, precipitating factors, surgical treatment and postoperative complications were all evaluated and compared with standard published literature. The total number of postoperative complications was reported in 13.9% patients, complications was high after Mesh repair when compared to Darning. Seroma was the most common complication followed by funiculitis and wound infection. There was one recurrence each noted till date in the two groups under study. Darn repair is equally effective and much less costly treatment for inguinal hernia than mesh repair which had more risk of infection.

  18. In-Space Repair and Refurbishment of Thermal Protection System Structures for Reusable Launch Vehicles

    Science.gov (United States)

    Singh, M.

    2007-01-01

    Advanced repair and refurbishment technologies are critically needed for the thermal protection system of current space transportation systems as well as for future launch and crew return vehicles. There is a history of damage to these systems from impact during ground handling or ice during launch. In addition, there exists the potential for in-orbit damage from micrometeoroid and orbital debris impact as well as different factors (weather, launch acoustics, shearing, etc.) during launch and re-entry. The GRC developed GRABER (Glenn Refractory Adhesive for Bonding and Exterior Repair) material has shown multiuse capability for repair of small cracks and damage in reinforced carbon-carbon (RCC) material. The concept consists of preparing an adhesive paste of desired ceramic with appropriate additives and then applying the paste to the damaged/cracked area of the RCC composites with an adhesive delivery system. The adhesive paste cures at 100-120 C and transforms into a high temperature ceramic during reentry conditions. A number of plasma torch and ArcJet tests were carried out to evaluate the crack repair capability of GRABER materials for Reinforced Carbon-Carbon (RCC) composites. For the large area repair applications, Integrated Systems for Tile and Leading Edge Repair (InSTALER) have been developed and evaluated under various ArcJet testing conditions. In this presentation, performance of the repair materials as applied to RCC is discussed. Additionally, critical in-space repair needs and technical challenges are reviewed.

  19. Endovascular repair of ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Šarac Momir

    2014-01-01

    Full Text Available Introduction. Rupture of an abdominal aortic aneurysm (AAA is a potentially lethal state. Only half of patients with ruptured AAA reach the hospital alive. The alternative for open reconstruction of this condition is endovascular repair (EVAR. We presented a successful endovascular reapir of ruptured AAA in a patient with a number of comorbidities. Case report. A 60-year-old man was admitted to our institution due to diffuse abdominal pain with flatulence and belching. Initial abdominal ultrasonography showed an AAA that was confirmed on multislice computed tomography scan angiography which revealed a large retroperitoneal haematoma. Because of patient’s comorbidites (previous surgery of laryngeal carcinoma and one-third laryngeal stenosis, arterial hypertension and cardiomyopathy with left ventricle ejection fraction of 30%, stenosis of the right internal carotid artery of 80% it was decided that endovascular repair of ruptured AAA in local anaesthesia and analgosedation would be treatment of choice. Endovascular grafting was achieved with aorto-bi-iliac bifurcated excluder endoprosthesis with complete exclusion of the aneurysmal sac, without further enlargment of haemathoma and no contrast leakage. The postoperative course of the patient was eventless, without complications. On recall examination 3 months after, the state of the patient was well. Conclusion. The alternative for open reconstruction of ruptured AAA in haemodynamically stable patients with suitable anatomy and comorbidities could be emergency EVAR in local anesthesia. This technique could provide greater chances for survival with lower intraoperative and postoperative morbidity and mortality, as shown in the presented patient.

  20. X-ray structure and computational study for N-acryloyl-L-valine, a versatile monomer for preparing smart drug delivery carriers

    Science.gov (United States)

    Tamasi, Gabriella; Casolaro, Mario; Cini, Renzo

    2012-12-01

    The title compound (NAV) has been synthesized by the acylation reaction of L-valine with acryloyl chloride, in alkaline solution. The X-ray crystal and molecular structure was solved and refined in the P212121 space group and was characterized by an almost coplanar H2Cdbnd CHsbnd C(dbnd O)sbnd N(sbnd H)sbnd C system, Cdbnd Csbnd Csbnd N, Cdbnd Csbnd Cdbnd O and (Cdbnd )Csbnd C(dbnd O)sbnd N(sbnd H)sbnd C torsion angles being +anti periplanar (+ap) (trans, +172(1)°), -syn periplanar (-sp, cys) (-8(1)°), and (-ap, trans) (-175(1)°). The carboxylic group plane is almost perpendicular to the amide plane (dihedral angle: 83(1)°) and the Odbnd Csbnd C(sbnd H)sbnd N(sbnd H) torsion angle is-sp, cys (-28(1)°). The Csbnd O bond distance at amide is 1.240(3) Å, whereas the Csbnd O bond distances at carboxylic group are 1.200(3) and 1.303(3) Å, respectively allowing an easy assignment of protonation site. The molecule has been theoretically analyzed via the methods of density functional theory DFT and semi-empirical quantum mechanics at PM3 level (SEQMPM3) in order to examine the conformational surface at the gas phase and in the presence of solvent molecules. The DFT computations at B3LYP/6-311++G** are the most reliable ones among those performed in this work (SEQMPM3, and B3LYP/6-31G**) as the agreement between computed and XRD bond parameters is excellent. Even the conformations are very reliable and the effect of the solvent was evaluated in a box of water molecules (at SEQMPM3) and through the PCM method at DFT for water, methanol, chloroform and other solvents.

  1. Computer-assisted resilience training to prepare healthcare workers for pandemic influenza: a randomized trial of the optimal dose of training

    Directory of Open Access Journals (Sweden)

    Vincent Leslie

    2010-03-01

    Full Text Available Abstract Background Working in a hospital during an extraordinary infectious disease outbreak can cause significant stress and contribute to healthcare workers choosing to reduce patient contact. Psychological training of healthcare workers prior to an influenza pandemic may reduce stress-related absenteeism, however, established training methods that change behavior and attitudes are too resource-intensive for widespread use. This study tests the feasibility and effectiveness of a less expensive alternative - an interactive, computer-assisted training course designed to build resilience to the stresses of working during a pandemic. Methods A "dose-finding" study compared pre-post changes in three different durations of training. We measured variables that are likely to mediate stress-responses in a pandemic before and after training: confidence in support and training, pandemic-related self-efficacy, coping style and interpersonal problems. Results 158 hospital workers took the course and were randomly assigned to the short (7 sessions, median cumulative duration 111 minutes, medium (12 sessions, 158 minutes or long (17 sessions, 223 minutes version. Using an intention-to-treat analysis, the course was associated with significant improvements in confidence in support and training, pandemic self-efficacy and interpersonal problems. Participants who under-utilized coping via problem-solving or seeking support or over-utilized escape-avoidance experienced improved coping. Comparison of doses showed improved interpersonal problems in the medium and long course but not in the short course. There was a trend towards higher drop-out rates with longer duration of training. Conclusions Computer-assisted resilience training in healthcare workers appears to be of significant benefit and merits further study under pandemic conditions. Comparing three "doses" of the course suggested that the medium course was optimal.

  2. Comparison of the Radiopacities of Different Root-End Filling and Repair Materials

    Science.gov (United States)

    Tanalp, Jale; Karapınar-Kazandağ, Meriç; Kayahan, Mehmet Baybora

    2013-01-01

    This study evaluated the radiopacity of 3 repair materials, Biodentine, MM-MTA, and MTA Angelus. Standardized cylindrical rings were prepared. Samples of Biodentine MM-MTA and MTA Angelus were prepared (n = 10 in each group), filled into the rings, and preserved at 37°C until setting. A 1 mm thick dentin slice was used as control. All set specimens were removed and radiographed along with the dentine slice and a graduated aluminium step wedge. Digital images were transferred to the computer using a software. The radiographic densities of the specimens were determined, and the values were converted into millimetres of aluminium (mm Al). One-way ANOVA was used for intergroup comparison, whereas Tukey HSD test was used for detecting the group with the difference. The mean radiopacities of Biodentine, MTA Angelus, and MM-MTA were 2.8 ± 0.48, 4.72 ± 0.45, and 5.18 ± 0.51 mm Al, respectively. The radiopacity of Biodentine was significantly lower compared to other materials (P = 0.001), whereas no significant difference was noted between MTA Angelus and MM-MTA (P = 0.109). All materials had significantly higher radiopacities compared to dentine. The relatively lower radiopacity of Biodentine can be improved to achieve more reliable results in procedures such as retrograde fillings. PMID:24260018

  3. Comparison of the Radiopacities of Different Root-End Filling and Repair Materials

    Directory of Open Access Journals (Sweden)

    Jale Tanalp

    2013-01-01

    Full Text Available This study evaluated the radiopacity of 3 repair materials, Biodentine, MM-MTA, and MTA Angelus. Standardized cylindrical rings were prepared. Samples of Biodentine MM-MTA and MTA Angelus were prepared ( in each group, filled into the rings, and preserved at 37°C until setting. A 1 mm thick dentin slice was used as control. All set specimens were removed and radiographed along with the dentine slice and a graduated aluminium step wedge. Digital images were transferred to the computer using a software. The radiographic densities of the specimens were determined, and the values were converted into millimetres of aluminium (mm Al. One-way ANOVA was used for intergroup comparison, whereas Tukey HSD test was used for detecting the group with the difference. The mean radiopacities of Biodentine, MTA Angelus, and MM-MTA were 2.8 ± 0.48, 4.72 ± 0.45, and 5.18 ± 0.51 mm Al, respectively. The radiopacity of Biodentine was significantly lower compared to other materials (, whereas no significant difference was noted between MTA Angelus and MM-MTA (. All materials had significantly higher radiopacities compared to dentine. The relatively lower radiopacity of Biodentine can be improved to achieve more reliable results in procedures such as retrograde fillings.

  4. Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.

    Science.gov (United States)

    Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı

    2016-11-23

    To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.

  5. Biomolecular Simulation of Base Excision Repair and Protein Signaling

    Energy Technology Data Exchange (ETDEWEB)

    Straatsma, TP; McCammon, J A; Miller, John H; Smith, Paul E; Vorpagel, Erich R; Wong, Chung F; Zacharias, Martin W

    2006-03-03

    The goal of the Biomolecular Simulation of Base Excision Repair and Protein Signaling project is to enhance our understanding of the mechanism of human polymerase-β, one of the key enzymes in base excision repair (BER) and the cell-signaling enzymes cyclic-AMP-dependent protein kinase. This work used molecular modeling and simulation studies to specifically focus on the • dynamics of DNA and damaged DNA • dynamics and energetics of base flipping in DNA • mechanism and fidelity of nucleotide insertion by BER enzyme human polymerase-β • mechanism and inhibitor design for cyclic-AMP-dependent protein kinase. Molecular dynamics simulations and electronic structure calculations have been performed using the computer resources at the Molecular Science Computing Facility at the Environmental Molecular Sciences Laboratory.

  6. Hands-on Approach to Prepare Specialists in Climate Changes Modeling and Analysis Using an Information-Computational Web-GIS Portal "Climate"

    Science.gov (United States)

    Shulgina, T. M.; Gordova, Y. E.; Martynova, Y. V.

    2014-12-01

    A problem of making education relevant to the workplace tasks is a key problem of higher education in the professional field of environmental sciences. To answer this challenge several new courses for students of "Climatology" and "Meteorology" specialties were developed and implemented at the Tomsk State University, which comprises theoretical knowledge from up-to-date environmental sciences with computational tasks. To organize the educational process we use an open-source course management system Moodle (www.moodle.org). It gave us an opportunity to combine text and multimedia in a theoretical part of educational courses. The hands-on approach is realized through development of innovative trainings which are performed within the information-computational web GIS platform "Climate" (http://climate.scert.ru/). The platform has a set of tools and data bases allowing a researcher to perform climate changes analysis on the selected territory. The tools are also used for students' trainings, which contain practical tasks on climate modeling and climate changes assessment and analysis. Laboratory exercises are covering three topics: "Analysis of regional climate changes"; "Analysis of climate extreme indices on the regional scale"; and "Analysis of future climate". They designed to consolidate students' knowledge of discipline, to instill in them the skills to work independently with large amounts of geophysical data using modern processing and analysis tools of web-GIS platform "Climate" and to train them to present results obtained on laboratory work as reports with the statement of the problem, the results of calculations and logically justified conclusion. Thus, students are engaged in n the use of modern tools of the geophysical data analysis and it cultivates dynamic of their professional learning. The approach can help us to fill in this gap because it is the only approach that offers experience, increases students involvement, advance the use of modern

  7. Delayed diagnosis of hemoptysis in the case of prior aortic coarctation repair: A case report of aortobronchial fistula

    Directory of Open Access Journals (Sweden)

    Vinay Kansal

    2015-01-01

    Full Text Available We report a case of a 46-year old man who presented with spontaneous bright red blood per mouth for several months. The patient had history of aortic coarctation repair at age 17. Endoscopy and nasopharyngeoscopy revealed no source of bleeding. Computed tomography scan revealed the presence of thoracic aortic pseudoaneurysm with the formation of an aortobronchial fistula (ABF. This case illustrates the high index of suspicion for ABF in the case of hemoptysis or hematemesis with prior history of coarctation repair. Furthermore, we discuss the role of thoracic endovascular aneurysm repair (TEVAR as the standard of repair over open surgery.

  8. Three-Dimensional Printed Prosthesis for Repair of Superior Canal Dehiscence.

    Science.gov (United States)

    Kozin, Elliott D; Remenschneider, Aaron K; Cheng, Song; Nakajima, Hideko Heidi; Lee, Daniel J

    2015-10-01

    Outcomes following repair of superior canal dehiscence (SCD) are variable, and surgery carries a risk of persistent or recurrent SCD symptoms, as well as a risk of hearing loss and vestibulopathy. Poor outcomes may occur from inadequate repair of the SCD or mechanical insult to the membranous labyrinth. Repair of SCD using a customized, fixed-length prosthesis may address current operative limitations and improve surgical outcomes. We aim to 3-dimensionally print customized prostheses to resurface or occlude bony SCD defects. Dehiscences were created along the arcuate eminence of superior semicircular canals in cadaveric temporal bones. Prostheses were designed and created using computed tomography and a 3-dimensional printer. The prostheses occupied the superior semicircular canal defect, reflected in postrepair computed tomography scans. This novel approach to SCD repair could have advantages over current techniques. Refinement of prosthesis design and materials will be important if this approach is translated into clinical use.

  9. A prospective study assessing the efficacy of abdominal computed tomography scan without bowel preparation in diagnosing intestinal wall and luminal lesions in patients presenting to the emergency room with abdominal complaints

    Institute of Scientific and Technical Information of China (English)

    Michal Mizrahi; Yoav Mintz; Avraham Rivkind; David Kisselgoff; Eugene Libson; Mayer Brezis; Eran Goldin; Oren Shibolet

    2005-01-01

    AIM: To evaluate the positive predictive value of abdominal non-prepared computed tomography (CT) for diagnosing intestinal lumen or wall lesions in patients presenting to the emergency room (ER) with abdominal complaints.METHODS: For 1-year we prospectively evaluated all ER patients hospitalized after abdominal CT scan detected either intraluminal or intestinal wall lesions. These patients underwent colonoscopy serving as gold standard. Patients with prior abdominal pathology or CT findings of appendicitis or diverticulitis were excluded.RESULTS: Five hundred and sixty-eight abdominopelvic CT scans were performed in the ER, 96 had positive colonic findings. Sixty-two patients were excluded, 46 because of diverticulitis or appendicitis, 16 because of prior abdominal pathology. Of the remaining 34 patients, 14 did not undergo colonoscopy during hospitalization.Twenty eligible patients were included in the study. The positive predictive value of the CT scans performed in the ER was calculated to be 45% (95% CI 25-67).CONCLUSION: CT findings correlated with colonoscopic findings only in approximately half of the cases. Relying on non-prepared CT scan findings in planning patient management and colonoscopy may lead to unnecessary diagnostic work-ups.

  10. THE WORK SIMULATION OF FLOW RATE FOR CARRIAGES' REPAIR AS A MULTIPHASE, MULTIPLEX AND MULTIDISCIPLINARY SYSTEM OF MASS SERVICE

    Directory of Open Access Journals (Sweden)

    V. V. Myamlin

    2011-04-01

    Full Text Available The algorithm of computer simulation of the flexible flow for repair of cars as a multiphase polychannel manyobject queuing system is presented. The basic operators of the model are given and their work is described.

  11. Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance

    DEFF Research Database (Denmark)

    Truijers, M; Resch, T; Van Den Berg, J C

    2009-01-01

    Endovascular aneurysm repair (EVAR) represents one of the greatest advances in vascular surgery over the past 50 years. In contrast to conventional aneurysm repair, EVAR requires accurate preoperative imaging and stringent postoperative surveillance. Duplex ultrasound (DUS), transesophageal...... echocardiography, intravascular ultrasound, computed tomography (CT) and magnetic resonance (MR), each provide useful information for patient selection, choice of endograft type and surveillance. Today most interventionists and surgeons will rely on CT or MR to assess aortic morphology, evaluate access artery...

  12. Probabilistic design and management of environmentally sustainable repair and rehabilitation of reinforced concrete structures

    DEFF Research Database (Denmark)

    Lepech, Michael D.; Geiker, Mette Rica; Stang, Henrik

    2014-01-01

    This paper presents a probabilistic sustainability design framework for the design of concrete repairs and rehabilitations intended to achieve targeted improvements in quantitative sustainability indicators. The framework consists of service life prediction models combining deterioration mechanisms...... to a probabilistic calculation of cumulative impacts throughout the structure's service life, from initial repair to functional obsolescence (end of life). The methods discussed are in accordance with sustainability design requirements within the 2010 fib Model Code. A case study is presented which computes...

  13. Influence of the glide path on various parameters of root canal prepared with WaveOne reciprocating file using cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Anil Dhingra

    2015-01-01

    Full Text Available Background: Nickel-titanium (NiTi rotary instrumentation carries a risk of fracture, mainly as a result of flexural (fatigue fracture and torsional (shear failure stresses. This risk might be reduced by creating a glide path before NiTi rotary instrumentation. The aim of this study was to compare various root canal parameters with the new WaveOne single-file reciprocating system in mesial canals of mandibular molars with and without glide path using cone beam computed tomography (CBCT. Materials and Methods: One hundred mandibular molar teeth with canal curvature between 20° and 30° were divided into two groups of 50 teeth each. In Group 1, no glide path was created, whereas in Group 2, a glide path was created with PathFiles at working length (WL. In both groups, canals were shaped with WaveOne primary reciprocating files to the WL. Canals were scanned in a CBCT unit before and after instrumentation. Postinstrumentation changes in canal curvature, cross-sectional area, centric ability, residual dentin thickness, and the extent of canal transportation were calculated using image analysis software and subjected to statistical analysis. Data were analyzed using Student′s t-test and Mann-Whitney U-test (P < 0.05. Results: The mean difference of root canal curvature, cross-sectional area, centric ability, and residual dentin thickness increased, whereas it reduced significantly for canal transportation in Group 2. Conclusion: WaveOne NiTi files appeared to maintain the original canal anatomy and the presence of a glide path further improves their performance and was found to be beneficial for all the parameters tested in this study.

  14. Nucleotide excision repair in the test tube.

    NARCIS (Netherlands)

    N.G.J. Jaspers (Nicolaas); J.H.J. Hoeijmakers (Jan)

    1995-01-01

    textabstractThe eukaryotic nucleotide excision-repair pathway has been reconstituted in vitro, an achievement that should hasten the full enzymological characterization of this highly complex DNA-repair pathway.

  15. Biological Augmentation of Rotator Cuff Tendon Repair

    National Research Council Canada - National Science Library

    Kovacevic, David; Rodeo, Scott A

    2008-01-01

    A histologically normal insertion site does not regenerate following rotator cuff tendon-to-bone repair, which is likely due to abnormal or insufficient gene expression and/or cell differentiation at the repair site...

  16. Cleft lip and palate repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000004.htm Cleft lip and palate repair - discharge To use the sharing ... Elsevier Saunders; 2015:chap 8. Read More Cleft lip and palate Cleft lip and palate repair Review Date 5/9/ ...

  17. Abdominal aortic aneurysm repair - open - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000240.htm Abdominal aortic aneurysm repair - open - discharge To use the sharing features ... References Orandi BJ, Black JH. Open repair of abdominal aortic aneurysms. In: Cameron JL, Cameron AM, eds. Current Surgical ...

  18. FREE GRAFT TWO-STAGE URETHROPLASTY FOR HYPOSPADIAS REPAIR

    Institute of Scientific and Technical Information of China (English)

    Zhong-jin Yue; Ling-jun Zuo; Jia-ji Wang; Gan-ping Zhong; Jian-ming Duan; Zhi-ping Wang; Da-shan Qin

    2005-01-01

    Objective To evaluate the effectiveness of free graft transplantation two-stage urethroplasty for hypospadias repair.Methods Fifty-eight cases with different types of hypospadias including 10 subcoronal, 36 penile shaft, 9 scrotal, and 3 perineal were treated with free full-thickness skin graft or (and) buccal mucosal graft transplantation two-stage urethroplasty. Of 58 cases, 45 were new cases, 13 had history of previous failed surgeries. Operative procedure included two stages: the first stage is to correct penile curvature (chordee), prepare transplanting bed, harvest and prepare full-thickness skin graft, buccal mucosal graft, and perform graft transplantation. The second stage is to complete urethroplasty and glanuloplasty.Results After the first stage operation, 56 of 58 cases (96.6%) were successful with grafts healing well, another 2foreskin grafts got gangrened. After the second stage operation on 56 cases, 5 cases failed with newly formed urethras opened due to infection, 8 cases had fistulas, 43 (76.8%) cases healed well.Conclusions Free graft transplantation two-stage urethroplasty for hypospadias repair is a kind of effective treatment with broad indication, comparatively high success rate, less complicationsand good cosmatic results, indicative of various types of hypospadias repair.

  19. Transvesicoscopic Repair of Vesicovaginal Fistula

    Directory of Open Access Journals (Sweden)

    R. B. Nerli

    2010-01-01

    Full Text Available Introduction. Vesicovaginal fistula has been a social and surgical problem for centuries. Many surgical techniques have been developed to correct this abnormality, including transabdominal, transvaginal, and endoscopic approaches. The best approach is probably the one with which the surgeon feels most experienced and comfortable. Laparoscopy has become increasingly popular in urology, reducing the invasiveness of treatment and shortening the period of convalescence. We report our results of transvesicoscopic approach for VVF repair. Materials and Methods. Patients with VVF were offered repair using the transvesicoscopic route. With the patient under general anaesthesia and in modified lithotomy position cystoscopy was performed with gas insufflation. Under cystoscopic guidance the bladder was fixed to anterior abdominal wall and ports inserted into the bladder. The fistula was repaired under endoscopic vision. Results. Four women, who had VVF following abdominal hysterectomy, underwent this procedure. The operating time ranged from 175 to 235 minutes. There was minimal bleeding. Post operative complications included ileus in one and fever in another. No recurrence of VVF was noted in any patient. Conclusions. Transvesicoscopic repair of VVF is feasible, safe, and results in lower morbidity and quicker recovery time.

  20. Small Crater Expedient Repair Test.

    Science.gov (United States)

    1980-08-01

    Force Base, New Mexico , October 1975. 3. Rollings, Raymond S., Laboratory Evaluation of Expedient Pavement Repair Materials, CEEDO-TR-7-44, Civil and...blank) APPENDIX A EQUIPMENT PERFORMANCE SP6WCIFICATIONS Performance specit’ications are included i.n tl is appe udi \\ tor the following equipment: 1

  1. Outcome of quadriceps tendon repair.

    Science.gov (United States)

    Puranik, Gururaj S; Faraj, Adnan

    2006-04-01

    Complete rupture of the quadriceps tendon is a well-described injury. There is a scarcity of literature relating to the outcome of patients with this injury after surgery. We undertook a retrospective analysis of patients who had surgical repair of their quadriceps tendon at our institution over a 13-year period, totalling 21 patients. Males were more commonly affected, with a male/female ratio of 4:1. The peak incidence was in the sixth decade of life. Assessment consisted of the completion of a functional knee questionnaire and a clinical examination. Symptomatic outcome following surgical repair was good with a mean symptom score generated of 19.16 out of a maximum of 25 using the Rougraff et al scoring system. Most of the patients returned to their pre-injury level of activity. Five degrees deficit and extension lag was present in three patients; these patients had the quadriceps repaired using transosseous sutures. Patients who had direct repair of the tendon using the Bunnell technique had lower Rougraff scores than the rest.

  2. How the Brain Repairs Stuttering

    Science.gov (United States)

    Kell, Christian A.; Neumann, Katrin; von Kriegstein, Katharina; Posenenske, Claudia; von Gudenberg, Alexander W.; Euler, Harald; Giraud, Anne-Lise

    2009-01-01

    Stuttering is a neurodevelopmental disorder associated with left inferior frontal structural anomalies. While children often recover, stuttering may also spontaneously disappear much later after years of dysfluency. These rare cases of unassisted recovery in adulthood provide a model of optimal brain repair outside the classical windows of…

  3. Microwave Oven Repair. Teacher Edition.

    Science.gov (United States)

    Smreker, Eugene

    This competency-based curriculum guide for teachers addresses the skills a technician will need to service microwave ovens and to provide customer relations to help retain the customer's confidence in the product and trust in the service company that performs the repair. The guide begins with a task analysis, listing 20 cognitive tasks and 5…

  4. Pure robotic retrocaval ureter repair

    Directory of Open Access Journals (Sweden)

    Ashok k. Hemal

    2008-12-01

    Full Text Available PURPOSE: To demonstrate the feasibility of pure robotic retrocaval ureter repair. MATERIALS AND METHODS: A 33 year old female presented with right loin pain and obstruction on intravenous urography with the classical "fish-hook" appearance. She was counseled on the various methods of repair and elected to have a robot assisted repair. The following steps are performed during a pure robotic retrocaval ureter repair. The patient is placed in a modified flank position, pneumoperitoneum created and ports inserted. The colon is mobilized to expose the retroperitoneal structures: inferior vena cava, right gonadal vein, right ureter, and duodenum. The renal pelvis and ureter are mobilized and the renal pelvis transected. The ureter is transposed anterior to the inferior vena cava and a pyelopyelostomy is performed over a JJ stent. RESULTS: This patient was discharged on postoperative day 3. The catheter and drain tube were removed on day 1. Her JJ stent was removed at 6 weeks postoperatively. The postoperative intravenous urography at 3 months confirmed normal drainage of contrast medium. CONCLUSION: Pure robotic retrocaval ureter is a feasible procedure; however, there does not appear to be any great advantage over pure laparoscopy, apart from the ergonomic ease for the surgeon as well the simpler intracorporeal suturing.

  5. [Complications of inguinal hernia repair].

    Science.gov (United States)

    Forte, A; D'Urso, A; Gallinaro, L S; Lo Storto, G; Bosco, M R; Vietri, F; Beltrami, V

    2002-03-01

    It's shown by literature and confirmed by Author's experience that, on account of the excellent results, prosthetic repair of inguinal hernia is more effective than "conventional" (Bassini, Mc Vay, Shouldice). Between January 1993 and December 2000 were observed 875 patients with inguinal hernia (814 monolateral, 61 bilateral); all patients underwent a Lichtenstein repair both in the primary version and in its variations (internal ring plastic, trasversalis plicate, plug repair). The patients were discharged from hospital within 24 hours after surgery in 90% of cases. No important intraoperative complications were observed; the patients restarting work varied from 3 to 15 days after the discharging in relation to patient anxiety, onset of complications and to the type of work. The complications observed were: urine retention (1.6%), superficial haematoma (1.3%), superficial infection (1%), wound suppuration (0.5%), serous effusion (0.7%), postsurgery pain (2.1%), scrotal edema (1.7%), persistent inguinal neuralgia (0.6), local hypoesthesia (4.3%), ischemical orchitis (0.1%), recurrence (0.2%). In conclusion Authors assert that "tension free" repair allows optimal results both for the surgery point (easiness of the technique, repeatability, less invasivity, scanty incident of recurrences, low frequency of postoperative complications) and in economic terms, allowing an early mobilization of the patients. A further improvement would be obtained with more care in surgical and patient management, with more excellent results.

  6. Fix-It Careers: Jobs in Repair

    Science.gov (United States)

    Torpey, Elka Maria

    2010-01-01

    From auto mechanic to HVAC technicians, many occupations require repair skills. For jobseekers with the right skills, there are many advantages to a repair career. Repair work provides millions of jobs throughout the United States. Wages are often higher than average. And in many occupations, the employment outlook is bright. Plus, most repair…

  7. 30 CFR 57.6801 - Vehicle repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Vehicle repair. 57.6801 Section 57.6801 Mineral... and Underground § 57.6801 Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair garage or shop....

  8. Nationwide prevalence of groin hernia repair

    DEFF Research Database (Denmark)

    Burcharth, Jakob; Pedersen, Michael; Bisgaard, Thue;

    2013-01-01

    Groin hernia repair is a commonly performed surgical procedure in the western world but large-scaled epidemiologic data are sparse. Large-scale data on the occurrence of groin hernia repair may provide further understanding to the pathophysiology of groin hernia development. This study was undert...... was undertaken to investigate the age and gender dependent prevalence of groin hernia repair....

  9. REPAIR MECHANISM IN FOREIGN LANGUAGE CLASSROOM INTERACTION

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This paper presents practical research on repair mechanismand its four repair trajectories in FL classroom interaction. Thisshows that it is effective and efficient in assisting FL learners todevelop their communicative competence and understand theprocess of language acquisition. Repair strategies that are ofgreat value to FL teachers in FL classroom teaching are also ex-pounded.

  10. Computer science a concise introduction

    CERN Document Server

    Sinclair, Ian

    2014-01-01

    Computer Science: A Concise Introduction covers the fundamentals of computer science. The book describes micro-, mini-, and mainframe computers and their uses; the ranges and types of computers and peripherals currently available; applications to numerical computation; and commercial data processing and industrial control processes. The functions of data preparation, data control, computer operations, applications programming, systems analysis and design, database administration, and network control are also encompassed. The book then discusses batch, on-line, and real-time systems; the basic

  11. Repairing the breech

    Directory of Open Access Journals (Sweden)

    Harry C. Boyte

    2012-04-01

    Full Text Available The main obstacle to genuine and productive partnerships between institutions of higher education and the professionals they prepare, on the one side, and communities, on the other, is a “knowledge war,” full of invisible hierarchies and exclusions, producing a hypercompetitive achievement culture. This knowledge war dramatically limits communities’ and citizens’ ability to act on the problems they face today. It also sharply erodes the power of higher education, professionals, and civic leaders to help shape the culture in democratic ways.We have to get beyond arrogant experts and aggrieved communities if we want to develop communities’ capacities to solve problems and also to generate a larger vision of a good society. Community is the living context for evaluating expert knowledge. But without engagement with other ways of knowing appeal to community knowledge can easily produce a Know-Nothing reaction to the larger world.If we are to build communities’ civic agency – capacities to work across differences to meet our common challenges – we need to democratize the politics of knowledge and end the knowledge war. This requires learning from effective community organizing the idea of “schools for public life,” where ordinary people develop skills, habits, and confidence of citizenship. It also means creating what might be called middle spaces, not owned by academics or professionals, but open to academic and scientific knowledge, where different ways of knowing and acting intermingle in creative ways. Middle spaces put science and academic knowledge in the mix, “on tap, not on top.” They also recognize the power and the limits of communal knowledge.Keywordscivic agency, cultural organizing, knowledge war

  12. Hand function after nerve repair.

    Science.gov (United States)

    Lundborg, G; Rosén, B

    2007-02-01

    Treatment of injuries to major nerve trunks in the hand and upper extremity remains a major and challenging reconstructive problem. Such injuries may cause long-lasting disabilities in terms of lost fine sensory and motor functions. Nowadays there is no surgical repair technique that can ensure recovery of tactile discrimination in the hand of an adult patient following nerve repair while very young individuals usually regain a complete recovery of functional sensibility. Post-traumatic nerve regeneration is a complex biological process where the outcome depends on multiple biological and environmental factors such as survival of nerve cells, axonal regeneration rate, extent of axonal misdirection, type of injury, type of nerve, level of the lesion, age of the patient and compliance to training. A major problem is the cortical functional reorganization of hand representation which occurs as a result of axonal misdirection. Although protective sensibility usually occurs following nerve repair, tactile discriminative functions seldom recover--a direct result of cortical remapping. Sensory re-education programmes are routinely applied to facilitate understanding of the new sensory patterns provided by the hand. New trends in hand rehabilitation focus on modulation of central nervous processes rather than peripheral factors. Principles are being evolved to maintain the cortical hand representation by using the brain capacity for visuo-tactile and audio-tactile interaction for the initial phase following nerve injury and repair (phase 1). After the start of the re-innervation of the hand (phase 2), selective de-afferentation, such as cutaneous anaesthesia of the forearm of the injured hand, allows expansion of the nerve-injured cortical hand representation, thereby enhancing the effects of sensory relearning. Recent data support the view that training protocols specifically addressing the relearning process substantially increase the possibilities for improved

  13. REPAIR TECHNOLOGY IMPROVEMENT OF SPECIALIZED FREIGHT CARS

    Directory of Open Access Journals (Sweden)

    V. M. Bubnov

    2016-02-01

    Full Text Available Purpose. The volume of cargo transportation demands the introduction of a new generation of cars that would be able to provide all the needs of carriers. But this is impossible without the implementation of renovation repair facilities with the introduction of new technologies and modernization of the repair process. Repair of rolling stock is a key factor that must proceed with the establishment of new cars, as not all of the inventions may be repaired in car-repair depots, most of which are obsolete. The purpose is to analyze the possibility of increasing the efficiency of the repair process by introducing new repair technologies or improving the existing ones. It will improve not only the quality of the repair, but also its rate. Methodology. Works on improving the designs of freight cars are held by many design organizations in almost all industrialized countries. It makes repair organizations (depots and car-repair plants to upgrade the repair process. Achievements of-this goal is possible by improving the technology renovation and reorganization through the use of flexible flow technologies, which to date are the most effective in the repair of rolling stock. Findings. When performing the analysis it was determined that there are different designs of cars. More of cars are all-purpose and their repair does not cause difficulties for car-repair business. However, the number of specialized cars is also significant, and the technology of their repair should be improved. One of the reasons is that many models, such as tank wagons for the carriage of sulfur, are intended for the carriage of dangerous goods and their failure at the time of motion is not permitted. Originality. Firstly the authors have defined direction at improving technologies of repair specialized cars. Practical value. Actual improvement in the construction of cars is to improve the existing repair facilities. In addition, the repair technology using nowadays when repairing

  14. Laparoscopic repair in children with traumatic bladder perforation.

    Science.gov (United States)

    Karadag, Cetin Ali; Tander, Burak; Erginel, Basak; Demirel, Dilek; Bicakci, Unal; Gunaydin, Mithat; Sever, Nihat; Bernay, Ferit; Dokucu, Ali Ihsan

    2016-01-01

    Here, we report two patients with a traumatic intraperitoneal bladder dome rupture repaired by laparoscopic intracorporeal sutures. The first patient was a 3-year old boy was admitted with a history of road accident. He had a traumatic lesion on his lower abdomen and a pelvic fracture. Computed tomography (CT) scan revealed free intraabdominal fluid. The urethragram showed spreading contrast material into the abdominal cavity. Laparoscopic exploration revealed a 3-cm-length perforation at the top of the bladder. The injury was repaired in a two fold fashion. Post-operative follow-up was uneventful. The second case was a 3-year-old boy fell from the second floor of his house on the ground. He had traumatic lesion on his lower abdomen and a pelvic fracture. Due to bloody urine drainage, a cystography was performed and an extravasation from the dome of the bladder into the peritoneum was detected. On laparoscopy, a 3-cm long vertical perforation at the dome of the bladder was found. The perforation was repaired in two layers with intracorporeal suture technique. The post-operative course was uneventful. Laparoscopic repair of traumatic perforation of the bladder dome is a safe, effective and minimally invasive method. The cosmetic outcome is superior.

  15. Laparoscopic repair in children with traumatic bladder perforation

    Directory of Open Access Journals (Sweden)

    Cetin Ali Karadag

    2016-01-01

    Full Text Available Here, we report two patients with a traumatic intraperitoneal bladder dome rupture repaired by laparoscopic intracorporeal sutures. The first patient was a 3-year old boy was admitted with a history of road accident. He had a traumatic lesion on his lower abdomen and a pelvic fracture. Computed tomography (CT scan revealed free intraabdominal fluid. The urethragram showed spreading contrast material into the abdominal cavity. Laparoscopic exploration revealed a 3-cm-length perforation at the top of the bladder. The injury was repaired in a two fold fashion. Post-operative follow-up was uneventful. The second case was a 3-year-old boy fell from the second floor of his house on the ground. He had traumatic lesion on his lower abdomen and a pelvic fracture. Due to bloody urine drainage, a cystography was performed and an extravasation from the dome of the bladder into the peritoneum was detected. On laparoscopy, a 3-cm long vertical perforation at the dome of the bladder was found. The perforation was repaired in two layers with intracorporeal suture technique. The post-operative course was uneventful. Laparoscopic repair of traumatic perforation of the bladder dome is a safe, effective and minimally invasive method. The cosmetic outcome is superior.

  16. Sensor-embedded computers for better life-cycle management

    Science.gov (United States)

    Vadde, Srikanth; Kamarthi, Sagar V.; Gupta, Surendra M.; Zeid, Ibrahim

    2004-12-01

    This research investigates the advantages offered by embedded sensors for cost-effective and environmentally benign product life cycle management for desktop computers. During their use by customers as well as at the end of their lives, Sensor Embedded Computers (SECs) by virtue of sensors embedded in them generate data and information pertaining to the conditions and remaining lives of important components such as hard-drive, motherboard, and power supply unit. A computer monitoring framework is proposed to provide more customer comfort, reduce repair costs and increase the effectiveness of current disassembly practices. The framework consists of SECs, remote monitoring center (RMC), repair/service, disassembly, and disposal centers. The RMC collects dynamic data/information generated by sensors during computer usage as well as static data/information from the original equipment manufacturers (OEMs). The RMC forwards this data/information to the repair/service, disassembly, and disposal centers on need-basis. The knowledge about the condition and remaining life of computer components can be advantageously used for planning repair/service and disassembly operations as well as for building refurbished computers with known expected lives. Simulation model of the framework is built and is evaluated in terms of the following performance measures: average downtime of a computer, average repair/service cost of a computer, average disassembly cost of a computer, and average life cycle cost of a computer. Test results show that embedding sensors in computers provides a definite advantage over conventional computers in terms of the performance measures.

  17. Repair of a bowel-containing, scrotal hernia with incarceration contributed by femorofemoral bypass graft

    Science.gov (United States)

    Sharma, Gaurav; Schouten, Jonathan A.; Itani, Kamal M. F.

    2017-01-01

    The rising use of endovascular techniques utilizing femoral artery access may increase the frequency with which surgeons face the challenge of hernia repair in reoperative groins—which may or may not include a vascular graft. We present a case where a vascular graft contributed to an acute presentation and complicated dissection, and review the literature. A 67-year-old man who had undergone prior endovascular aneurysm repair via open bilateral femoral artery access and concomitant prosthetic femorofemoral bypass, presented with an incarcerated, scrotal inguinal hernia. The graft with its associated fibrosis contributed to the incarceration by compressing the inguinal ring. Repair was undertaken via an open, anterior approach with tension-free, Lichtenstein herniorraphy after releasing graft-associated fibrosis. Repair of groin hernias in this complex setting requires careful surgical planning, preparation for potential vascular reconstruction and meticulous technique to avoid bowel injury in the face of a vascular conduit and mesh. PMID:28069880

  18. Repair of mismatched basepairs in mammalian DNA. Progress report, March 1, 1990--February 28, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J.H.; Hare, J.T.

    1991-08-01

    We have concentrated on three specific areas of our research plan. Our greatest emphasis is on the role of single strand nicks in influencing template strand selection in mismatch repair. We have found, that the ability of a nick in one strand to influence which strand is repaired is not a simple function of distance from the mismatched site but rather that an hot spot where a nick is more likely to have an influence can exist. The second line was production of single-genotype heteroduplexes in order to examine independently the repair of T/G and A/C mispairs within the same sequence context as in our mixed mispair preparations. We have shown preparations of supercoiled heteroduplex can be prepared that were exclusively T/G or exclusively A/C at the mispair site. The third effort has been to understand the difference in repair bias of different cell lines or different transfection conditions as it may relate to different repair systems in the cell. We have identified some of the sources of variation, including cell cycle position. We hope to continue this work to more precisely identify the phase of the cell cycle.

  19. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  20. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p rotator cuff repairability were tear size (p rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  1. Minimally disruptive schedule repair for MCM missions

    Science.gov (United States)

    Molineaux, Matthew; Auslander, Bryan; Moore, Philip G.; Gupta, Kalyan M.

    2015-05-01

    Mine countermeasures (MCM) missions entail planning and operations in very dynamic and uncertain operating environments, which pose considerable risk to personnel and equipment. Frequent schedule repairs are needed that consider the latest operating conditions to keep mission on target. Presently no decision support tools are available for the challenging task of MCM mission rescheduling. To address this capability gap, we have developed the CARPE system to assist operation planners. CARPE constantly monitors the operational environment for changes and recommends alternative repaired schedules in response. It includes a novel schedule repair algorithm called Case-Based Local Schedule Repair (CLOSR) that automatically repairs broken schedules while satisfying the requirement of minimal operational disruption. It uses a case-based approach to represent repair strategies and apply them to new situations. Evaluation of CLOSR on simulated MCM operations demonstrates the effectiveness of case-based strategy. Schedule repairs are generated rapidly, ensure the elimination of all mines, and achieve required levels of clearance.

  2. Development and validation of bonded composite doubler repairs for commercial aircraft.

    Energy Technology Data Exchange (ETDEWEB)

    Roach, Dennis Patrick; Rackow, Kirk A.

    2007-07-01

    repair using a substandard design and a flawed installation. In addition, the new Sol-Gel surface preparation technique was evaluated. Fatigue coupon tests produced Sol-Gel results that could be compared with a large performance database from conventional, riveted repairs. It was demonstrated that not only can composite doublers perform well in severe off-design conditions (low doubler stiffness and presence of defects in doubler installation) but that the Sol-Gel surface preparation technique is easier and quicker to carry out while still producing optimum bonding properties. Nondestructive inspection (NDI) methods were developed so that the potential for disbond and delamination growth could be monitored and crack growth mitigation could be quantified. The NDI methods were validated using full-scale test articles and the FedEx aircraft installations. It was demonstrated that specialized NDI techniques can detect flaws in composite doubler installations before they reach critical size. Probability of Detection studies were integrated into the FedEx training in order to quantify the ability of aircraft maintenance depots to properly monitor these repairs. In addition, Boeing Structural Repair and Nondestructive Testing Manuals were modified to include composite doubler repair and inspection procedures. This report presents the results from the FedEx Pilot Program that involved installation and surveillance of numerous repairs on operating aircraft. Results from critical NDI evaluations are reported in light of damage tolerance assessments for bonded composite doublers. This work has produced significant interest from airlines and aircraft manufacturers. The successful Pilot Program produced flight performance history to establish the durability of bonded composite patches as a permanent repair on commercial aircraft structures. This report discusses both the laboratory data and Pilot Program results from repair installations on operating aircraft to introduce composite

  3. APPLICATION OF COMPUTED TOMOGRAPHIC ANGIOGRAPHY IN REPAIRING SKIN DEFECT AFTER SCALP AVULSION WITH FREE LATISSIMUS DORSI FLAP TRANSPLANTATION%CT血管造影在背阔肌皮瓣游离移植修复头皮撕脱伤创面中的应用

    Institute of Scientific and Technical Information of China (English)

    何永静; 王继华; 杨云; 刘垠; 张景波; 朱礼昆; 郭树忠; 朱剑萍; 刘红莉

    2013-01-01

    目的 探讨CT血管造影(computed tomographic angiography,CTA)及三维重建技术在背阔肌皮瓣游离移植修复头皮撕脱伤伴大面积颅骨外露创面中的应用价值.方法 2007年10月-2012年6月,收治9例严重头皮撕脱伤伴大面积颅骨外露女性患者.年龄23~54岁,平均38岁.致伤原因:机器绞伤6例,交通事故伤2例,高处坠落伤1例.其中3例伤后行头皮原位回植后坏死,6例行清创包扎.伤后至入院时间8h~7d,平均1d.头皮撕脱范围为头皮面积的75%~90%,平均81%;颅骨外露范围为头皮面积的55%~70%,平均63%;2例伴单侧耳廓撕脱.术前对面颈部及背部血管行CTA及三维重建,分析颞浅动、静脉,面动脉,颈外静脉和胸背动、静脉解剖结构并测量管径.根据CTA检查结果,7例以背阔肌皮瓣修复创面,2例以背阔肌肌瓣联合植皮修复.7例患者根据术前设计顺利完成手术;2例术前颞浅血管显示较差者,以大隐静脉作为移植血管与相关血管吻合.背阔肌皮瓣切取范围20 cm×14 cm~25 cm×20 cm,供区减张缝合后植皮修复;肌瓣切取面积分别为23 cm×16 cm及16cm×10cm,供区直接缝合.结果 术中血管管径测量结果与术前比较差异较小,不影响血管吻合.手术时间6~8 h,平均6.5h.术后背阔肌肌(皮)瓣及植皮均成活,创面Ⅰ期愈合;供区切口Ⅰ期愈合.患者均获随访,随访时间3个月~2年,平均6个月.皮瓣质地柔软,皮肤无破溃.结论 采用背阔肌皮瓣游离移植修复头皮撕脱伤伴大面积颅骨外露创面时,术前可行CTA检查明确供、受区可供吻合的血管解剖结构及管径,指导手术方案设计及实施,以缩短手术时间,提高术中血管吻合准确率.%Objective To investigate the clinical value of computed tomographic angiography (CTA) and three-dimensional reconstruction technique in repairing scalp avulsion wound with large skull exposure by the free latissimus dorsi flap

  4. Methods of repairing a substrate

    Science.gov (United States)

    Riedell, James A. (Inventor); Easler, Timothy E. (Inventor)

    2011-01-01

    A precursor of a ceramic adhesive suitable for use in a vacuum, thermal, and microgravity environment. The precursor of the ceramic adhesive includes a silicon-based, preceramic polymer and at least one ceramic powder selected from the group consisting of aluminum oxide, aluminum nitride, boron carbide, boron oxide, boron nitride, hafnium boride, hafnium carbide, hafnium oxide, lithium aluminate, molybdenum silicide, niobium carbide, niobium nitride, silicon boride, silicon carbide, silicon oxide, silicon nitride, tin oxide, tantalum boride, tantalum carbide, tantalum oxide, tantalum nitride, titanium boride, titanium carbide, titanium oxide, titanium nitride, yttrium oxide, zirconium boride, zirconium carbide, zirconium oxide, and zirconium silicate. Methods of forming the ceramic adhesive and of repairing a substrate in a vacuum and microgravity environment are also disclosed, as is a substrate repaired with the ceramic adhesive.

  5. Solution preparation

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, M.G.

    1982-01-01

    Reviewed in this statement are methods of preparing solutions to be used in laboratory experiments to examine technical issues related to the safe disposal of nuclear waste from power generation. Each approach currently used to prepare solutions has advantages and any one approach may be preferred over the others in particular situations, depending upon the goals of the experimental program. These advantages are highlighted herein for three approaches to solution preparation that are currently used most in studies of nuclear waste disposal. Discussion of the disadvantages of each approach is presented to help a user select a preparation method for his particular studies. Also presented in this statement are general observations regarding solution preparation. These observations are used as examples of the types of concerns that need to be addressed regarding solution preparation. As shown by these examples, prior to experimentation or chemical analyses, laboratory techniques based on scientific knowledge of solutions can be applied to solutions, often resulting in great improvement in the usefulness of results.

  6. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2015-10-01

    IL, Kochevar IE, Redmond RW. Large extremity peripheral nerve repair. Military Health System Research Symposium (MHSRS) Fort Lauderdale, FL. August...some notable discoveries that may impact military health care in the near future. There is a clear need in military medicine to improve outcomes in...membranes or “caul” intact was considered extremely lucky. Children were gifted with life-long happiness , the ability to see spirits, and protection

  7. Shelf Stable Epoxy Repair Adhesive

    Science.gov (United States)

    2015-02-01

    manufacturing operations are more efficient , discarding less expired film. Commercial and military aircraft repair operations at Boeing experience very similar...successfully encapsulated at concentrations greater than 50 wt% within four N N = CC Infoscitex Corporation Shelf Stable Epoxy Resin Adhesive WP-1763 8...affects the composition of the encapsulant , which in turn affects the ability of the encapsulant to wet the core phase, the barrier properties of the

  8. Repair and regeneration in endodontics.

    Science.gov (United States)

    Lin, L M; Rosenberg, P A

    2011-10-01

    The ideal objective of treatment of established diseases, including irreversible pulpitis and apical periodontitis, is to achieve wound healing. Wound healing can result in repair or regeneration. The ultimate goal of wound healing is to restore the original architecture and biological function of the injured tissue or organ. Although humans are equipped with powerful innate and adaptive immune defence mechanisms, many intrinsic and extrinsic factors can affect wound healing. Complete regeneration following injury in humans can occur only in the pre-natal foetus within 24 weeks of gestation. Post-natal wounds including irreversible pulpitis or apical periodontitis always heal by repair or by a combination of repair and regeneration. Somatic cells, such as fibroblasts, macrophages, cementoblasts and osteoblasts, in the pulp and periapical tissues have limited potential for regeneration following injury and lack of telomerase. Wound healing of irreversible pulpitis and apical periodontitis requires recruitment and differentiation of progenitor/stem cells into tissue-committed somatic cells. Stem cell differentiation is regulated by intrinsic factors and extrinsic micro-environmental cues. Functionality of stem cells appears to show an age-related decline because of the change in intrinsic properties and diminished signals within the extrinsic local and systemic environment that modulate the function of stem cells or their progeny. Infection induces an immuno-inflammatory response and tissue destruction, which hinders the potential of tissue regeneration. Therefore, prevention, early detection and treatment of inflammation/infection of pulpal and periapical disease can enhance regeneration and minimize the repair of pulpal and periapical tissues after endodontic therapy. © 2011 International Endodontic Journal.

  9. Pain after groin hernia repair

    DEFF Research Database (Denmark)

    Callesen, T; Bech, K; Nielsen, R

    1998-01-01

    BACKGROUND: The purpose of the study was to provide a detailed description of postoperative pain after elective day-case open inguinal hernia repair under local anaesthesia. METHODS: This was a prospective consecutive case series study. After 500 hernia operations in 466 unselected patients aged 18...... between types of surgery or hernia. CONCLUSION: Pain remained a problem despite the pre-emptive use of opioids, non-steroidal anti-inflammatory drugs and local anaesthesia, irrespective of surgical technique....

  10. Biologics for tendon repair

    OpenAIRE

    2014-01-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately,...

  11. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2016-12-01

    71. Burman S, Tejwani S, Vemuganti GK. Ophthalmic applications of preserved human amniotic membrane: a review of current indications. Cell Tissue Bank...segmental nerve deficit repair using isograft show the best performing wrap/ fixation method to be sutureless photochemical tissue bonding with the...crosslinked amnion wrap. Autograft is often unavailable in wounded warriors, due to extensive tissue damage and amputation and, importantly, we also

  12. Fabrication Flaw Density and Distribution In Repairs to Reactor Pressure Vessel and Piping Welds

    Energy Technology Data Exchange (ETDEWEB)

    GJ Schuster, FA Simonen, SR Doctor

    2008-04-01

    The Pacific Northwest National Laboratory is developing a generalized fabrication flaw distribution for the population of nuclear reactor pressure vessels and for piping welds in U.S. operating reactors. The purpose of the generalized flaw distribution is to predict component-specific flaw densities. The estimates of fabrication flaws are intended for use in fracture mechanics structural integrity assessments. Structural integrity assessments, such as estimating the frequency of loss-of-coolant accidents, are performed by computer codes that require, as input, accurate estimates of flaw densities. Welds from four different reactor pressure vessels and a collection of archived pipes have been studied to develop empirical estimates of fabrication flaw densities. This report describes the fabrication flaw distribution and characterization in the repair weld metal of vessels and piping. This work indicates that large flaws occur in these repairs. These results show that repair flaws are complex in composition and sometimes include cracks on the ends of the repair cavities. Parametric analysis using an exponential fit is performed on the data. The relevance of construction records is established for describing fabrication processes and product forms. An analysis of these records shows there was a significant change in repair frequency over the years when these components were fabricated. A description of repair flaw morphology is provided with a discussion of fracture mechanics significance. Fabrication flaws in repairs are characterized using optimized-access, high-sensitivity nondestructive ultrasonic testing. Flaw characterizations are then validated by other nondestructive evaluation techniques and complemented by destructive testing.

  13. Computer science I essentials

    CERN Document Server

    Raus, Randall

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Computer Science I includes fundamental computer concepts, number representations, Boolean algebra, switching circuits, and computer architecture.

  14. Revisional laparoscopic parastomal hernia repair.

    Science.gov (United States)

    Zacharakis, Emmanouil; Shalhoub, Joseph; Selvapatt, Nowlan; Darzi, Ara; Ziprin, Paul

    2008-01-01

    We herein report a laparoscopically performed re-do operation on a patient who had previously undergone a laparoscopic parastomal hernia repair. We describe the case of a 71-year-old patient who presented within 3 months of her primary laparoscopic parastomal hernia repair with recurrence. On relaparoscopy, dense adhesions to the mesh were found, and the mesh had migrated into the hernia sac. This had allowed loops of small bowel to herniate into the sac. The initial part of the procedure involved the lysis of adhesions. A piece of Gore-Tex DualMesh with a central keyhole and a radial slit was cut so that it could provide at least 3 cm to 5 cm of overlap of the fascial defect. The tails of the mesh were wrapped around the bowel, and the mesh was secured to the margins of the hernia with circumferential metal tacking and 4 transfascial sutures. The patient remains in satisfactory condition and no recurrence or any surgery-related problem has been observed during 8 months of follow-up. Revisional laparoscopic repair of parastomal hernias seems feasible and has been shown to be safe and effective in this case. The success of this approach depends on longer follow-up reports and standardization of the technical elements.

  15. Endovascular stent graft repair of multiple tuberculous thoracoabdominal aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Jung; Won, Je Hwan [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2014-05-15

    We describe a case of multiple tuberculous aneurysms of the descending thoracic aorta and abdominal aorta repaired with endovascular stent graft. The case was a 47-year-old man who presented with three saccular pseudoaneurysms of aortoiliac bifurcation at computed tomography (CT) scan. Despite of antimycobacterial treatment, these aneurysms grew rapidly and saccular pseudoaneurysm of the descending thoracic aorta was newly seen. A bifurcated stent graft was successfully implanted in the aortoiliac bifurcation. Subsequently, endovascular stent graft was placed well in the descending thoracic aorta. Fourteen months after the procedure, the patient was stable and serial CT images showed regression of aneurysms with ongoing antimycobacterial treatment. Therefore, endovascular stent graft repair with antimycobacterial therapy may be a treatment option in patients with multiple tuberculous aneurysms.

  16. Histomorphometric and ultrastructural analysis of the tendon-bone interface after rotator cuff repair in a rat model.

    Science.gov (United States)

    Kanazawa, Tomonoshin; Gotoh, Masafumi; Ohta, Keisuke; Honda, Hirokazu; Ohzono, Hiroki; Shimokobe, Hisao; Shiba, Naoto; Nakamura, Kei-Ichiro

    2016-09-20

    Successful rotator cuff repair requires biological anchoring of the repaired tendon to the bone. However, the histological structure of the repaired tendon-bone interface differs from that of a normal tendon insertion. We analysed differences between the normal tendon insertion and the repaired tendon-bone interface after surgery in the mechanical properties, histomorphometric analysis, and 3-dimensional ultrastructure of the cells using a rat rotator cuff repair model. Twenty-four adult Sprague-Dawley (SD) rats underwent complete cuff tear and subsequent repair of the supraspinatus tendon. The repaired tendon-bone interface was evaluated at 4, 8, and 12 weeks after surgery. At each time point, shoulders underwent micro-computed tomography scanning and biomechanical testing (N = 6), conventional histology and histomorphometric analysis (N = 6), and ultrastructural analysis with focused ion beam/scanning electron microscope (FIB/SEM) tomography (N = 4). We demonstrated that the cellular distribution between the repaired tendon and bone at 12 weeks after surgery bore similarities to the normal tendon insertion. However, the ultrastructure of the cells at any time point had a different morphology than those of the normal tendon insertion. These morphological differences affect the healing process, partly contributing to re-tearing at the repair site. These results may facilitate future studies of the regeneration of a normal tendon insertion.

  17. Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

    Science.gov (United States)

    Chauhan, Aakash; Schimoler, Patrick; Miller, Mark C; Kharlamov, Alexander; Merrell, Gregory A; Palmer, Bradley A

    2017-04-01

    The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.

  18. ADJUSTMENT, MAINTENANCE, AND REPAIR OF CROP HARVESTING MACHINERY. AGRICULTURAL MACHINERY--SERVICE OCCUPATIONS, MODULE NUMBER 11.

    Science.gov (United States)

    Ohio State Univ., Columbus. Center for Vocational and Technical Education.

    ONE OF A SERIES DESIGNED FOR HELPING TEACHERS PREPARE POSTSECONDARY-LEVEL STUDENTS FOR AGRICULTURAL MACHINERY SERVICE OCCUPATIONS AS PARTS MEN, MECHANICS, MECHANIC'S HELPERS, AND SERVICE SUPERVISORS, THIS GUIDE AIMS TO DEVELOP STUDENT COMPETENCY IN ADJUSTING, REPAIRING, AND MAINTAINING CROP HARVESTING MACHINERY. SUGGESTIONS FOR INTRODUCTION OF THE…

  19. ADJUSTMENT, MAINTENANCE, AND REPAIR OF SMALL GASOLINE ENGINES. AGRICULTURAL MACHINERY--SERVICE OCCUPATIONS, MODULE NUMBER 12.

    Science.gov (United States)

    Ohio State Univ., Columbus. Center for Vocational and Technical Education.

    ONE OF A SERIES DESIGNED TO HELP TEACHERS PREPARE POSTSECONDARY STUDENTS FOR THE AGRICULTURAL MACHINERY SERVICE OCCUPATIONS AS PARTS MEN, MECHANICS, MECHANIC'S HELPERS, OR SERVICE SUPERVISORS, THIS GUIDE AIMS TO DEVELOP STUDENT COMPETENCY IN THE ADJUSTMENT, MAINTENANCE, AND REPAIR OF SMALL GASOLINE ENGINES. IT WAS DEVELOPED BY A NATIONAL TASK…

  20. Bond strength of repaired amalgam restorations.

    Science.gov (United States)

    Rey, Rosalia; Mondragon, Eduardo; Shen, Chiayi

    2015-01-01

    This in vitro study investigated the interfacial flexural strength (FS) of amalgam repairs and the optimal combination of repair materials and mechanical retention required for a consistent and durable repair bond. Amalgam bricks were created, each with 1 end roughened to expose a fresh surface before repair. Four groups followed separate repair protocols: group 1, bonding agent with amalgam; group 2, bonding agent with composite resin; group 3, mechanical retention (slot) with amalgam; and group 4, slot with bonding agent and amalgam. Repaired specimens were stored in artificial saliva for 1, 10, 30, 120, or 360 days before being loaded to failure in a 3-point bending test. Statistical analysis showed significant changes in median FS over time in groups 2 and 4. The effect of the repair method on the FS values after each storage period was significant for most groups except the 30-day storage groups. Amalgam-amalgam repair with adequate condensation yielded the most consistent and durable bond. An amalgam bonding agent could be beneficial when firm condensation on the repair surface cannot be achieved or when tooth structure is involved. Composite resin can be a viable option for amalgam repair in an esthetically demanding region, but proper mechanical modification of the amalgam surface and selection of the proper bonding system are essential.

  1. Treatment and Controversies in Paraesophageal Hernia Repair

    Directory of Open Access Journals (Sweden)

    P. Marco eFisichella

    2015-04-01

    Full Text Available Background: Historically all paraesophageal hernias were repaired surgically, today intervention is reserved for symptomatic paraesophageal hernias. In this review, we describe the indications for repair and explore the controversies in paraesophageal hernia repair, which include a comparison of open to laparoscopic paraesophageal hernia repair, the necessity of complete sac excision, the routine performance of fundoplication, and the use of mesh for hernia repair.Methods: We searched Pubmed for papers published between 1980 and 2015 using the following keywords: hiatal hernias, paraesophageal hernias, regurgitation, dysphagia, gastroesophageal reflux disease, aspiration, GERD, endoscopy, manometry, pH monitoring, proton pump inhibitors, anemia, iron deficiency anemia, Nissen fundoplication, sac excision, mesh, mesh repair. Results: Indications for paraesophageal hernia repair have changed, and currently symptomatic paraesophageal hernias are recommended for repair. In addition, it is important not to overlook iron-deficiency anemia and pulmonary complaints, which tend to improve with repair. Current practice favors a laparoscopic approach, complete sac excision, primary crural repair with or without use of mesh, and a routine fundoplication.

  2. Effect of Moisture Exchange on Interface Formation in the Repair System Studied by X-ray Absorption

    Directory of Open Access Journals (Sweden)

    Mladena Lukovic

    2015-12-01

    Full Text Available In concrete repair systems, material properties of the repair material and the interface are greatly influenced by the moisture exchange between the repair material and the substrate. If the substrate is dry, it can absorb water from the repair material and reduce its effective water-to-cement ratio (w/c. This further affects the hydration rate of cement based material. In addition to the change in hydration rate, void content at the interface between the two materials is also affected. In this research, the influence of moisture exchange on the void content in the repair system as a function of initial saturation level of the substrate is investigated. Repair systems with varying level of substrate saturation are made. Moisture exchange in these repair systems as a function of time is monitored by the X-ray absorption technique. After a specified curing age (3 d, the internal microstructure of the repair systems was captured by micro-computed X-ray tomography (CT-scanning. From reconstructed images, different phases in the repair system (repair material, substrate, voids can be distinguished. In order to quantify the void content, voids were thresholded and their percentage was calculated. It was found that significantly more voids form when the substrate is dry prior to application of the repair material. Air, initially filling voids and pores of the dry substrate, is being released due to the moisture exchange. As a result, air voids remain entrapped in the repair material close to the interface. These voids are found to form as a continuation of pre-existing surface voids in the substrate. Knowledge about moisture exchange and its effects provides engineers with the basis for recommendations about substrate preconditioning in practice.

  3. Development of Nano-biomaterials for Bone Repair

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    A new kind of nano-biomaterials of nano apatite ( NA ) and polyamide8063 ( PA ) composite was prepared by direct using NA slurry. The experimental results showed that the NA content in the composite was similar to that of natural bone. Interface chemical bonding was formed between NA and PA. The NA keeps the original morphological structure with a crystal size of 10- 30 nm in width by 50- 90 nm in length with a ratio of~ 2.5 and distributed uniformly in the polymer. The synthetic nano-biomaterials could be one of the best bioactive materials for load-bearing bone repair or substitution materials.

  4. Surgical management of the failed SLAP repair.

    Science.gov (United States)

    Weber, Stephen C

    2010-09-01

    Repair of superior labral tears anterior to posterior (SLAP) lesions has become an increasingly common procedure, despite the low incidence rates reported in the literature. As the incidence of these procedures increases, the surgeons will be increasingly confronted with patients with painful shoulders after SLAP repair. Persistent pain after SLAP repair is multifactorial; careful preoperative workup is necessary to elucidate the cause of pain. Simple failure of the prior SLAP repair will rarely be the cause of persistent pain. Use of tacks is especially worrisome, and suture anchor repair is preferable. Articular cartilage injuries because of either bioabsorbable or metal hardware will often create significant residual disability. Recent literature suggests that older patients may be better served by primary biceps tenodesis rather than SLAP repair.

  5. DNA-Protein Crosslink Proteolysis Repair.

    Science.gov (United States)

    Vaz, Bruno; Popovic, Marta; Ramadan, Kristijan

    2017-06-01

    Proteins that are covalently bound to DNA constitute a specific type of DNA lesion known as DNA-protein crosslinks (DPCs). DPCs represent physical obstacles to the progression of DNA replication. If not repaired, DPCs cause stalling of DNA replication forks that consequently leads to DNA double-strand breaks, the most cytotoxic DNA lesion. Although DPCs are common DNA lesions, the mechanism of DPC repair was unclear until now. Recent work unveiled that DPC repair is orchestrated by proteolysis performed by two distinct metalloproteases, SPARTAN in metazoans and Wss1 in yeast. This review summarizes recent discoveries on two proteases in DNA replication-coupled DPC repair and establishes DPC proteolysis repair as a separate DNA repair pathway for genome stability and protection from accelerated aging and cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Repairing sealing surfaces on aluminum castings

    Science.gov (United States)

    Hanna, T. L.

    1980-01-01

    Approach using stylus nickel plating instead of copper and cadmium plating has simplified repair procedure. Damaged sealing surfaces are stylus nickelplated in one step. Superficial scratches and porous areas are removed more easily from repaired surface by simply lapping sealing areas to required finish. Although method is aimed for aerospace components, it may be easily incorporated into conventional aluminumcasting technology. One-step repair can be considered for cast-aluminum automobile and aircraft engines to reduce time and costs.

  7. Research on Hot Gunning Repairing in Laboratory

    Institute of Scientific and Technical Information of China (English)

    CAO Feng; LONG Shigang; MENG Qingmin; SUN Jialin; HONG Yanruo

    2003-01-01

    The lining of blast furnace may be damaged partly,so that gunning repair is needed. The bonding strength of boundary surface between the repairing layer and remained lining of blast furnace has been studied by thermal simulation.The factors influencing the bonding strength are the ingredient gunning repair temperature,remained lining condition and water content of gunning refractory.The bonding strength decreases with the increases of remained lining temperature.

  8. Role of ubiquitination in meiotic recombination repair

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Programmed and unprogrammed double-strand breaks (DSBs) often arise from such physiological requirements as meiotic recombination, and exogenous insults, such as ionizing radiation (IR). Due to deleterious impacts on genome stability, DSBs must be appropriately processed and repaired in a regulatory manner. Recent investigations have indicated that ubiquitination is a critical factor in DNA damage response and meiotic recombination repair. This review summarizes the effects of proteins and complexes associated with ubiquitination with regard to homologous recombination (HR)-dependent DSB repair.

  9. DNA repair enzymes: an important role in skin cancer prevention and reversal of photodamage--a review of the literature.

    Science.gov (United States)

    Kabir, Yasmeen; Seidel, Rachel; Mcknight, Braden; Moy, Ronald

    2015-03-01

    The incidence of skin cancer continues to increase annually despite preventative measures. Non-melanoma skin cancer affects more than 1,000,000 people in the United States every year.1 The current preventative measures, such as sunscreens and topical antioxidants, have not shown to be effective in blocking the effects of UV radiation based on these statistics. The level of antioxidants contained in the majority of skin creams is not sufficient to majorly impact free radical damage. Sunscreens absorb only a portion of UV radiation and often are not photostable. In this review article, we present the novel use of exogenous DNA repair enzymes and describe their role in combating photocarcinogenesis and photoaging. Topical application of these enzymes serves to supplement intrinsic DNA repair mechanisms. The direct repair of DNA damage by endogenous repair enzymes lessens rates of mutagenesis and strengthens the immune response to tumor cells. However, these innate mechanisms are not 100% efficient. The use of exogenous DNA repair enzymes presents a novel way to supplement intrinsic mechanisms and improve their efficacy. Several DNA repair enzymes critical to the prevention of cutaneous malignancies have been isolated and added to topical preparations designed for skin cancer prevention. These DNA repair enzymes maximize the rate of DNA repair and provide a more efficient response to carcinogenesis.

  10. Difluoromethane preparation

    NARCIS (Netherlands)

    Wiersma, A.; Sandt, E.J.A.; Van Bekkum, H.; Makkee, M.; Moulijn, J.A.

    1996-01-01

    Abstract of NL 9401574 (A) The invention relates to a method for preparing difluoromethane, wherein dichlorodifluoromethane or monochlorodifluoromethane is brought into contact with hydrogen in the presence of palladium on activated carbon, wherein the loading of the palladium on the activated c

  11. Extensor tendon repair an overview

    Directory of Open Access Journals (Sweden)

    Mansoor Bin Fayed

    2015-04-01

    Full Text Available The incidence of extensor injuries is more than that of flexor tendon injuries. This is to a great extent because of the extensors being superficially placed and covered by skin and subcutaneous tissue over the distal part of the upper extremity. Thus they are more vulnerable to blunt and sharp trauma, the proximal and distal forearm present with laceration and cut with sharp weapon. Extensor tendon injuries are often taken lightly by many, repairs being taken-up at the ER. Repair is done in or if the retrieval of tendon ends is difficult or the wound is complicated with associated injuries such as fractures or in cases of tendon retraction. Delayed primary repair can be undertaken from 7-10 days. Assessment of the injured finger has to be very meticulous. Extension of finger is brought about by the interossei and lumbricals which are the short muscles of the hand. They extend the proximal interphalangeal joints and distal interphalangeal joints and flex metacarpophalangeal joint, these intrinsic muscles are innervated by the ulnar and median nerves. The long extensors are innervated by the radial nerve, they primarily extend the metacarpophalangeal joints and also interphalangeal joints. In cases of injury the intrinsic system may compensate for an extensor deficit. Closed injuries of zone I may be managed by splinting of the distal interphalangeal joints and open injuries in the zone I and II can be treated with tenodermodesis. Proximal interphalangeal joints and distal interphalangeal joints are immobilized in zone 3 and 4. Metacarpophalangeal joint is immobilized in full extension and the wrist in 10o extension.

  12. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  13. 33 CFR 127.405 - Repairs.

    Science.gov (United States)

    2010-07-01

    ... FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Maintenance § 127.405 Repairs. The operator shall ensure that—...

  14. Changes in DNA repair during aging

    Science.gov (United States)

    Gorbunova, Vera; Seluanov, Andrei; Mao, Zhiyong; Hine, Christpher

    2007-01-01

    DNA is a precious molecule. It encodes vital information about cellular content and function. There are only two copies of each chromosome in the cell, and once the sequence is lost no replacement is possible. The irreplaceable nature of the DNA sets it apart from other cellular molecules, and makes it a critical target for age-related deterioration. To prevent DNA damage cells have evolved elaborate DNA repair machinery. Paradoxically, DNA repair can itself be subject to age-related changes and deterioration. In this review we will discuss the changes in efficiency of mismatch repair (MMR), base excision repair (BER), nucleotide excision repair (NER) and double-strand break (DSB) repair systems during aging, and potential changes in DSB repair pathway usage that occur with age. Mutations in DNA repair genes and premature aging phenotypes they cause have been reviewed extensively elsewhere, therefore the focus of this review is on the comparison of DNA repair mechanisms in young versus old. PMID:17913742

  15. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    INTRODUCTION: The optimal repair of inguinal hernias remains controversial. It is recommended that an inguinal hernia be repaired using a mesh, either with a laparoscopic or an open approach. In Denmark, the laparoscopic approach is used in an increasing number of cases. The laparoscopic repair has...... clinical trial described in this protocol is to evaluate chronic pain after inguinal hernia repair using the ONSTEP method versus the laparoscopic approach. METHODS: This study is designed as a non-inferiority, two-arm, multicentre, randomised clinical trial, with a 1:1 allocation to ONSTEP or laparoscopic...

  16. Vesicocervical fistula following vesicovaginal fistula repair report

    Directory of Open Access Journals (Sweden)

    Hamudur Rahman

    2016-07-01

    Full Text Available Vesicocervical fistula following vesicovaginal fistula repair is a very rare condition. It is a complication following repeated lower uterine cesarean section. We report a case of an young married woman who was admitted in the depart­ment of urology, Banghabandhu Sheikh Mujib Medical University Hospital with vesico-cervical fistula following vesico­vaginal fistula repair. Reposition of cervix into vaginal vault and repair of urinary bladder was done. There was no such report of vesicocervical fistula following vesicovaginal fistula repair from Bangladesh.

  17. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    INTRODUCTION: The optimal repair of inguinal hernias remains controversial. It is recommended that an inguinal hernia be repaired using a mesh, either with a laparoscopic or an open approach. In Denmark, the laparoscopic approach is used in an increasing number of cases. The laparoscopic repair has...... clinical trial described in this protocol is to evaluate chronic pain after inguinal hernia repair using the ONSTEP method versus the laparoscopic approach. METHODS: This study is designed as a non-inferiority, two-arm, multicentre, randomised clinical trial, with a 1:1 allocation to ONSTEP or laparoscopic...

  18. Complex networks repair strategies: Dynamic models

    Science.gov (United States)

    Fu, Chaoqi; Wang, Ying; Gao, Yangjun; Wang, Xiaoyang

    2017-09-01

    Network repair strategies are tactical methods that restore the efficiency of damaged networks; however, unreasonable repair strategies not only waste resources, they are also ineffective for network recovery. Most extant research on network repair focuses on static networks, but results and findings on static networks cannot be applied to evolutionary dynamic networks because, in dynamic models, complex network repair has completely different characteristics. For instance, repaired nodes face more severe challenges, and require strategic repair methods in order to have a significant effect. In this study, we propose the Shell Repair Strategy (SRS) to minimize the risk of secondary node failures due to the cascading effect. Our proposed method includes the identification of a set of vital nodes that have a significant impact on network repair and defense. Our identification of these vital nodes reduces the number of switching nodes that face the risk of secondary failures during the dynamic repair process. This is positively correlated with the size of the average degree and enhances network invulnerability.

  19. Root justifications for ontology repair

    CSIR Research Space (South Africa)

    Moodley, K

    2011-08-01

    Full Text Available stream_source_info Moodley_2011.pdf.txt stream_content_type text/plain stream_size 32328 Content-Encoding ISO-8859-1 stream_name Moodley_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Root Justi cations... the ontology, based on the no- tion of root justi cations [8, 9]. In Section 5, we discuss the implementation of a Prot eg e3 plugin which demonstrates our approach to ontology repair. In this section we also discuss some experimental results comparing...

  20. Arthroscopic Transosseous Bony Bankart Repair

    Science.gov (United States)

    Driscoll, Matthew D.; Burns, Joseph P.; Snyder, Stephen J.

    2015-01-01

    Restoration of glenoid bony integrity is critical to minimizing the risk of recurrence and re-creating normal kinematics in the setting of anterior glenohumeral instability. We present an arthroscopic suture anchor–based technique for treating large bony Bankart fractures in which the fragment is secured to the intact glenoid using mattress sutures placed through the bony fragment and augmented with soft-tissue repair proximal and distal to the bony lesion. This straightforward technique has led to excellent fragment reduction and good outcomes in our experience. PMID:25973373

  1. 40 CFR 60.482-9 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Delay of repair. 60.482-9... Standards: Delay of repair. (a) Delay of repair of equipment for which leaks have been detected will be allowed if repair within 15 days is technically infeasible without a process unit shutdown. Repair of...

  2. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  3. A Primer on Wound Bed Preparation

    OpenAIRE

    Gokoo, Chuck

    2009-01-01

    Successful wound closure and healing are a major concern for today's clinician. Determining if the wound will progress or not relies on a comprehensive assessment, recognition of wound characteristics that will promote or impede the healing process and preparing the wound bed such that pathological features are removed allowing the healing cascade to occur. When complications are no longer a roadblock the wound will achieve a stable microenvironment and progress through the normal repairative...

  4. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian

    2016-03-25

    Data repairing aims at discovering and correcting erroneous data in databases. Traditional methods relying on predefined quality rules to detect the conflict between data may fail to choose the right way to fix the detected conflict. Recent efforts turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes the advantages of both rule-based method and crowd-based method. Particularly, we investigate the interaction between crowd-based repairing and rule-based repairing, and show that by doing crowd-based repairing to a small portion of values, we can greatly improve the repairing quality of the rule-based repairing method. Although we prove that the optimal interaction scheme using the least number of values for crowd-based repairing to maximize the imputation recall is not feasible to be achieved, still, our proposed solution identifies an efficient scheme through investigating the inconsistencies and the dependencies between values in the repairing process. Our empirical study on three data collections demonstrates the high repairing quality of CrowdAidRepair, as well as the efficiency of the generated interaction scheme over baselines.

  5. Initiating Repair and Beyond: The Use of Two Repeat-Formatted Repair Initiations in Mandarin Conversation

    Science.gov (United States)

    Wu, Ruey-Jiuan Regina

    2006-01-01

    As part of a growing effort to understand the organization of repair across languages, this study examines 2 repeat-formatted other-initiated repair practices in Mandarin conversation. Using the methodology of conversation analysis as a central framework, this study shows that the 2 Mandarin repair initiations under examination, like…

  6. X-ray repair cross complementing protein 1 in base excision repair

    DEFF Research Database (Denmark)

    Hanssen-Bauer, Audun; Solvang-Garten, Karin; Akbari, Mansour;

    2012-01-01

    X-ray Repair Cross Complementing protein 1 (XRCC1) acts as a scaffolding protein in the converging base excision repair (BER) and single strand break repair (SSBR) pathways. XRCC1 also interacts with itself and rapidly accumulates at sites of DNA damage. XRCC1 can thus mediate the assembly of large...

  7. A preparação de material terminológico em língua inglesa por meio de ferramentas linguístico-computacionais Preparation of terminological material in english by means of computational linguistic tools

    Directory of Open Access Journals (Sweden)

    Eduardo Batista da Silva

    2011-06-01

    Full Text Available O objetivo desse estudo é demonstrar, por meio de análise quantitativa e qualitativa, a eficácia de ferramentas linguístico-computacionais na seleção de terminologia para a produção de material terminológico. Serão apresentadas duas ferramentas linguístico-computacionais (WordSmith Tools e VocabProfile e, também, sugestões para que o ensino de termos ofereça resultados práticos. A fundamentação teórico-metodológica recorreu a Barros (2004; Berber Sardinha (2000; 2005; Biderman (2001; Cabré (2007; Cobb (2007; Nation, (2003 e Sinclair (2004. O corpus da pesquisa foi constituído exclusivamente de material escrito na língua inglesa em diversas áreas de especialidade. Os procedimentos de preparação de material terminológico são exemplificados a partir de uma das áreas de especialidades utilizadas nos corpora de pesquisa, as Redes Neurais Artificiais. Os resultados obtidos indicam que a utilização do Wordsmith Tools juntamente com o VocabProfile pode fornecer dados importantes para a pesquisa linguistica.This paper aims to demonstrate by means of quantitative and qualitative analyses the effectiveness of the linguistic computational tools in selecting terminology for the production of terminological material. Two linguistic computational tools will be introduced (WordSmith Tools e VocabProfile and also suggestions so as the teaching of terms may offer practical results. The theoretical-methodological approach relies on Barros (2004; Berber Sardinha (2000; 2005; Biderman (2001; Cabré (2007; Cobb (2007; Nation (2003 and Sinclair (2004. The research corpus was made solely of written material in English in several specialty languages. The procedures regarding terminological material preparation are exemplified with one of the specialty fields used in the research corpus, the Artificial Neural Networks. The obtained results indicate that the use of Wordsmith Tools in conjunction with VocabProfile might provide useful data for

  8. Electrospun composites of PHBV/pearl powder for bone repairing

    Directory of Open Access Journals (Sweden)

    Jingjing Bai

    2015-08-01

    Full Text Available Electrospun fiber has highly structural similarity with natural bone extracelluar matrix (ECM. Many researches about fabricating organic–inorganic composite materials have been carried out in order to mimic the natural composition of bone and enhance the biocompatibility of materials. In this work, pearl powder was added to the poly (3-hydroxybutyrate-co-3-hydroxyvalerate (PHBV and the composite nanofiber scaffold was prepared by electrospinning. Mineralization ability of the composite scaffolds can be evaluated by analyzing hydroxyapatite (HA formation on the surface of nanofiber scaffolds. The obtained composite nanofiber scaffolds showed an enhanced mineralization capacity due to incorporation of pearl powder. The HA formed amount of the composite scaffolds was raised as the increase of pearl powder in composite scaffolds. Therefore, the prepared PHBV/pearl composite nanofiber scaffolds would be a promising candidate as an osteoconductive composite material for bone repairing.

  9. Electrospun composites of PHBV/pearl powder for bone repairing

    Institute of Scientific and Technical Information of China (English)

    Jingjing Bai; Jiamu Dai; Guang Li

    2015-01-01

    Electrospun fiber has highly structural similarity with natural bone extracelluar matrix (ECM). Many researches about fabricating organic–inorganic composite materials have been carried out in order to mimic the natural composition of bone and enhance the biocompatibility of materials. In this work, pearl powder was added to the poly (3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and the composite nanofiber scaffold was prepared by electrospinning. Mineralization ability of the composite scaffolds can be evaluated by analyzing hydroxyapatite (HA) formation on the surface of nanofiber scaffolds. The obtained composite nanofiber scaffolds showed an enhanced mineralization capacity due to incorporation of pearl powder. The HA formed amount of the composite scaffolds was raised as the increase of pearl powder in composite scaffolds. Therefore, the prepared PHBV/pearl composite nanofiber scaffolds would be a promising candidate as an osteoconductive composite material for bone repairing.

  10. Repairability of Compomers with Different Methods of Surface Conditioning

    Directory of Open Access Journals (Sweden)

    P.Samimi

    2005-06-01

    Full Text Available Statement of Problem: Considering the cost and amount of time and also the quantity of tooth loss in the process of cavity preparation, repair of the restoration instead of itsreplacement would be much more efficient.Purpose: The aim of this study was to determine the effect of different methods of surface conditioning on the shear bond strength of repaired compomers.Materials and Methods: Sixty blocks of compomer were prepared in acrylic molds and then they were randomly divided into five groups of 12. Group I (control groupreceived no treatment. The remaining samples were immersed in 37 ºC distilled water for one week, then the surfaces were roughened with a coarse diamond bur. Samples ineach group were prepared by different surface treatment and conditioning: In group II specimens were conditioned with 35% phosphoric acid for 20s. Specimens in group III were etched with 10% polyacrylic acid for 20s. In group IV 1.23% acidulated phosphatefluoride was applied for 30s, and compomer surfaces were sandblasted with 50μm Al2O3 powder in group V. After the initial preparations, all groups were treated with silane and resin before bonding of the second mix of compomer. Shear forces were applied with a universal testing machine at a cross-head speed of 5mm/min. The data were analyzed using one-way ANOVA and Duncan's multiple range tests.Results: The mean shear bond strengths and standard deviations (in parentheses for groups I to V were 31.56(10.86, 20.02(5.49, 17.74(7.34, 19.31(4.31 and 27.7(6.33MPa, respectively. The mean bond strengths for Groups I and V were significantly higher than that of the other groups (P<0.05.Conclusion: The results showed that among the surface treatments used in this study,sandblasting with alumina could be the best surface preparation method for repairing compomer restorations.

  11. Technologies for repairing peripheral nerve injury Progress in domestic and foreign investigations

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    OBJECTIVE: Studies on the repair of peripheral nerve injury have achieved great progresses in recent years.Clinical nerve repair prefers microsurgery, while fundamental researches focus on tissue engineering and gene therapy. Recently, microencapsulation technique rises up as a new treatment therapy. This article mainly summarized the repairing techniques referred above, in order to make the basis for further research.DATA SOURCES: A computer-based online search of Pubmed database was undertaken to identify articles about injury and repair of peripheral nerve published in English between January 1997 and May 2007 using the key words of "peripheral nerve, injury, repair". At the same time, Chinese relative articles were searched in China National Knowledge Infrastructure (CNKI) using the same key words in Chinese.STUDY SELECTION: The data were primarily checked, and the references after each literature were looked up, and the articles focused on the injury and repair of peripheral nerve were selected. Those published in kola-magazine in recent 5 years were in priority for the articles with similar contents. Repetitive studies or Meta analysis were excluded.DATA EXTRACTION: Totally 144 articles were collected, and 30 literatures were selected as most relative reference literatures, and the other 114 articles were excluded due to old or repeated researches. Among the 30 selected articles, 6 focused on the surgical treatment for peripheral nerve injury, 10 on tissue engineering and Schwann cell, 3 on microencapsulation technology, 5 on gene therapy, 2 on immunosuppresant and 4 on neurotrophic factors.DATA SYNTHESIS: The technologies for repairing peripheral nerve injury are developing with time, also have been successfully combined with tissue engineering and gene therapy techniques which are advanced nowadays. As the researches go further, immunodepression factors have attracted more and more attentions,microencapsulation technology and gene therapy repair also go

  12. Repair of overheating linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Barkley, Walter; Baldwin, William; Bennett, Gloria; Bitteker, Leo; Borden, Michael; Casados, Jeff; Fitzgerald, Daniel; Gorman, Fred; Johnson, Kenneth; Kurennoy, Sergey; Martinez, Alberto; O’Hara, James; Perez, Edward; Roller, Brandon; Rybarcyk, Lawrence; Stark, Peter; Stockton, Jerry

    2004-01-01

    Los Alamos Neutron Science Center (LANSCE) is a proton accelerator that produces high energy particle beams for experiments. These beams include neutrons and protons for diverse uses including radiography, isotope production, small feature study, lattice vibrations and material science. The Drift Tube Linear Accelerator (DTL) is the first portion of a half mile long linear section of accelerator that raises the beam energy from 750 keV to 100 MeV. In its 31st year of operation (2003), the DTL experienced serious issues. The first problem was the inability to maintain resonant frequency at full power. The second problem was increased occurrences of over-temperature failure of cooling hoses. These shortcomings led to an investigation during the 2003 yearly preventative maintenance shutdown that showed evidence of excessive heating: discolored interior tank walls and coper oxide deposition in the cooling circuits. Since overheating was suspected to be caused by compromised heat transfer, improving that was the focus of the repair effort. Investigations revealed copper oxide flow inhibition and iron oxide scale build up. Acid cleaning was implemented with careful attention to protection of the base metal, selection of components to clean and minimization of exposure times. The effort has been very successful in bringing the accelerator through a complete eight month run cycle allowing an incredible array of scientific experiments to be completed this year (2003-2004). This paper will describe the systems, investigation analysis, repair, return to production and conclusion.

  13. Regenerative endodontics: regeneration or repair?

    Science.gov (United States)

    Simon, Stéphane R J; Tomson, Phillip L; Berdal, Ariane

    2014-04-01

    Recent advances in biotechnology and translational research have made it possible to provide treatment modalities that protect the vital pulp, allow manipulation of reactionary and reparative dentinogenesis, and, more recently, permit revascularization of an infected root canal space. These approaches are referred to as regenerative procedures. The method currently used to determine the origin of the tissue secreted during the repair/regeneration process is largely based on the identification of cellular markers (usually proteins) left by cells that were responsible for this tissue production. The presence of these proteins in conjunction with other indicators of cellular behavior (especially biomineralization) and analysis of the structure of the newly generated tissue allow conclusions to be made of how it was formed. Thus far, it has not been possible to truly establish the biological mechanism controlling tertiary dentinogenesis. This article considers current therapeutic techniques to treat the dentin-pulp complex and contextualize them in terms of reparative and regenerative processes. Although it may be considered a semantic argument rather than a biological one, the definitions of regeneration and repair are explored to clarify our position in this era of regenerative endodontics. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Nationwide prevalence of groin hernia repair.

    Directory of Open Access Journals (Sweden)

    Jakob Burcharth

    Full Text Available INTRODUCTION: Groin hernia repair is a commonly performed surgical procedure in the western world but large-scaled epidemiologic data are sparse. Large-scale data on the occurrence of groin hernia repair may provide further understanding to the pathophysiology of groin hernia development. This study was undertaken to investigate the age and gender dependent prevalence of groin hernia repair. METHODS: In a nationwide register-based study, using data from the Civil Registration System covering all Danish citizens, we established a population-based cohort of all people living in Denmark on December 31(st, 2010. Within this population all groin hernia repairs during the past 5 years were identified using data from the ICD 10(th edition in the Danish National Hospital Register. RESULTS: The study population covered n = 5,639,885 persons. During the five years study period 46,717 groin hernia repairs were performed (88.6% males, 11.4% females. Inguinal hernias comprised 97% of groin hernia repairs (90.2% males, 9.8% females and femoral hernias 3% of groin hernia repairs (29.8% males, 70.2% females. Patients between 0-5 years and 75-80 years constituted the two dominant groups for inguinal hernia repair. In contrast, the age-specific prevalence of femoral hernia repair increased steadily throughout life peaking at age 80-90 years in both men and women. CONCLUSION: The age distribution of inguinal hernia repair is bimodal peaking at early childhood and old age, whereas the prevalence of femoral hernia repair increased steadily throughout life. This information can be used to formulate new hypotheses regarding disease etiology with regard to age and gender specifications.

  15. Mucocele After Orbital Fracture Repair Masquerading as Optic Neuritis.

    Science.gov (United States)

    Park, Jongyeop; Kim, Jinhyun; Choi, Jinsu; Kim, Hochang

    2016-06-01

    The authors report a patient of mucocele formation after orbital wall fracture repair masquerading as optic neuritis.A 38-year-old man with a history of medial orbital wall fracture repair with an alloplastic implant 10 years previously, presented with left visual disturbance and mild ocular pain with movement of the left eye of 3-day duration, and a relative afferent papillary defect in his left eye. He reported having cold symptoms 2 weeks before presentation. His symptoms were typical of retrobulbar optic neuritis. Under suspicion of optic neuritis, computed tomography and magnetic resonance imaging were performed and revealed a large cyst in the sphenoid sinus and ethmoid sinus, just behind the alloplastic implant, that was compressing the medial rectus muscle and optic nerve of the left eye. The patient underwent endoscopic marsupialization of the cyst. Subsequent histologic examinations revealed a cyst lined with ciliated pseudostratified columnar epithelium. The patient had an uncomplicated postoperative course and the visual disturbance resolved. For patients who present solely with optic neuropathy after orbital fracture repair, it is important to be vigilant of potentially rare cause, mucocele formation.

  16. Diffuse Supravalvular Aortic Stenosis: Surgical Repair in Adulthood

    Directory of Open Access Journals (Sweden)

    Giovanni Ferlan

    2009-01-01

    Full Text Available We present the case of a 54-year-old woman in which a diffuse congenital supravalvular aortic stenosis (SVAS was associated with a severe aortic valve incompetence and heavy calcification of the aortic annulus. Repair consisted in resection of the ascending aorta, patch augmentation of the hypoplastic aortic root and annulus, placement of a 20 mm Dacron tubular graft (Vascutek, Renfrewshire, UK and aortic valve replacement with a mechanical prosthesis (Sorin, Turin, Italy. Follow-up echocardiography demonstrated normal prosthetic valve function and a postoperative three-dimensional computed tomographic scan showed a normal shape of the reconstructed ascending aorta.

  17. [Endovascular repair for coarctation of the aorta in an adult].

    Science.gov (United States)

    Hayashi, Jun; Abe, Kazuo; Hata, Masaki; Nagano, Naoko; Hamasaki, Azumi; Suzuki, Kenji

    2013-09-01

    A 27-year-old woman with Turner's syndrome who underwent successful endovascular treatment for coarctation of the aorta is presented. She was admitted to our hospital complaining of upper extremity hypertension. Computed tomography revealed discrete stenosis of the proximal descending aorta and developed collateral circulation. After endovascular repair with a balloon expandable stent, her transcoarctation gradient fell from 44 mmHg preoperatively to less than 10 mmHg. She was discharged with no complications on the 7th postoperative day. Coarctation of the aorta in an adult patient could be safely and effectively managed by endovascular treatment.

  18. Distribution of DNA repair-related ESTs in sugarcane

    Directory of Open Access Journals (Sweden)

    W.C. Lima

    2001-12-01

    Full Text Available DNA repair pathways are necessary to maintain the proper genomic stability and ensure the survival of the organism, protecting it against the damaging effects of endogenous and exogenous agents. In this work, we made an analysis of the expression patterns of DNA repair-related genes in sugarcane, by determining the EST (expressed sequence tags distribution in the different cDNA libraries of the SUCEST transcriptome project. Three different pathways - photoreactivation, base excision repair and nucleotide excision repair - were investigated by employing known DNA repair proteins as probes to identify homologous ESTs in sugarcane, by means of computer similarity search. The results showed that DNA repair genes may have differential expressions in tissues, depending on the pathway studied. These in silico data provide important clues on the potential variation of gene expression, to be confirmed by direct biochemical analysis.As vias de reparo de DNA são requeridas para manter a necessária estabilidade genômica e garantir a sobrevivência do organismo, frente aos efeitos deletérios causados por fatores endógenos e exógenos. Neste trabalho, realizamos a análise dos padrões de expressão dos genes de reparo de DNA encontrados na cana-de-açúcar, pela determinação da distribuição de ESTs nas diferentes bibliotecas de cDNA no projeto de transcriptoma SUCEST. Três vias de reparo - fotorreativação, reparo por excisão de bases e reparo por excisão de nucleotídeos - foram estudadas através do uso de proteínas de reparo como sondas para identificação de ESTs homólogos em cana-de-açúcar, com base na procura computacional de similaridade. Os resultados indicam que os genes de reparo de DNA possuem uma expressão diferencial nos tecidos, dependendo da via de reparo analisada. Esses dados in silico fornecem importantes indícios da expressão diferencial, a qual deve ser confirmada por análises bioquímicas diretas.

  19. On failure of the pruning technique in "error repair in shift-reduce parsers"

    NARCIS (Netherlands)

    Bertsch, E; Nederhof, MJ

    1999-01-01

    A previous article presented a technique to compute the least-cost error repair by incrementally generating configurations that result from inserting and deleting tokens in a syntactically incorrect input. An additional mechanism to improve the run-time efficiency of this algorithm by pruning some o

  20. Flow networks analysis and optimization of repairable flow networks, networks with disturbed flows, static flow networks and reliability networks

    CERN Document Server

    Todinov, Michael T

    2013-01-01

    Repairable flow networks are a new area of research, which analyzes the repair and flow disruption caused by failures of components in static flow networks. This book addresses a gap in current network research by developing the theory, algorithms and applications related to repairable flow networks and networks with disturbed flows. The theoretical results presented in the book lay the foundations of a new generation of ultra-fast algorithms for optimizing the flow in networks after failures or congestion, and the high computational speed creates the powerful possibility of optimal control

  1. Image-Guided Techniques Improve the Short-Term Outcome of Autologous Osteochondral Cartilage Repair Surgeries

    Science.gov (United States)

    Devlin, Steven M.; Hurtig, Mark B.; Waldman, Stephen D.; Rudan, John F.; Bardana, Davide D.; Stewart, A. James

    2013-01-01

    Objective: Autologous osteochondral cartilage repair is a valuable reconstruction option for cartilage defects, but the accuracy to harvest and deliver osteochondral grafts remains problematic. We investigated whether image-guided methods (optically guided and template guided) can improve the outcome of these procedures. Design: Fifteen sheep were operated to create traumatic chondral injuries in each knee. After 4 months, the chondral defect in one knee was repaired using (a) conventional approach, (b) optically guided method, or (c) template-guided method. For both image-guided groups, harvest and delivery sites were preoperatively planned using custom-made software. During optically guided surgery, instrument position and orientation were tracked and superimposed onto the surgical plan. For the template-guided group, plastic templates were manufactured to allow an exact fit between template and the joint anatomy. Cylindrical holes within the template guided surgical tools according to the plan. Three months postsurgery, both knees were harvested and computed tomography scans were used to compare the reconstructed versus the native pre-injury joint surfaces. For each repaired defect, macroscopic (International Cartilage Repair Society [ICRS]) and histological repair (ICRS II) scores were assessed. Results: Three months after repair surgery, both image-guided surgical approaches resulted in significantly better histology scores compared with the conventional approach (improvement by 55%, P < 0.02). Interestingly, there were no significant differences found in cartilage surface reconstruction and macroscopic scores between the image-guided and the conventional surgeries. PMID:26069658

  2. Improvement of adhesion performance of mortar-repair interface with inducing crack path into repair

    Directory of Open Access Journals (Sweden)

    A. Satoh

    2015-10-01

    Full Text Available The most important performance for repair materials is adhesion to the substrate. The authors experimentally find out that high modulus fine aggregates in repair material enhance strength of it as well as the strength of the interface repaired with it, compared to the ordinary repair without fine aggregates. This paper elaborates the mechanisms for that with fractographic observation and FEM analysis based on the results of experiment. Also the authors discuss the ways for enhancing the strength and ductility of the repaired mortar

  3. 28 Comparative Study of Open Mesh Repair and Desarda's No ...

    African Journals Online (AJOL)

    user

    2006-12-02

    Dec 2, 2006 ... East And Central African Journal of Surgery Volume 11 Number 2. ... new technique and the open mesh repair done in a district level general hospital set ... laparoscopic repairs or the patients given ..... Hernia repair (Open Vs.

  4. International congress on DNA damage and repair: Book of abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    This document contains the abstracts of 105 papers presented at the Congress. Topics covered include the Escherichia coli nucleotide excision repair system, DNA repair in malignant transformations, defective DNA repair, and gene regulation. (TEM)

  5. 30 CFR 56.6801 - Vehicle repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a...

  6. DNA repair mechanisms in C. elegans

    NARCIS (Netherlands)

    Brouwer, K.|info:eu-repo/dai/nl/336462557

    2009-01-01

    DNA is the carrier of genetic information. DNA is constantly damaged by, for example, UV light and X-rays. Cells can utilize a large number of proteins that can repair the damages, thereby avoiding changes in the DNA sequence. Damages that are not repaired result in an increase in the number of muta

  7. Damage diagnosis and compatible repair mortars

    NARCIS (Netherlands)

    Hees, R.P.J. van

    1999-01-01

    Mortars for repair and maintenance of historic masonry have to meet specific requirements. Several authors have made contributions, however many cases of failure show that there still is quite a lack of knowledge on the compatibility of repair mortars for historic masonry. The diagnosis of the cause

  8. Laparoscopic Ventral and Incisional Hernia Repair

    NARCIS (Netherlands)

    Wassenaar, E.B.

    2009-01-01

    Ventral and incisional hernia repair is one of the most frequently performed operations in daily surgical practice. Laparoscopic ventral and incisional hernia repair (LVIHR) is gaining increasing adoption in surgical practice. It has theoretical advantages but improvements in technique can still be

  9. Thoraco-abdominal aortic aneurysm branched repair

    NARCIS (Netherlands)

    Verhoeven, E. L. G.; Tielliu, I. F. J.; Ferreira, M.; Zipfel, B.; Adam, D. J.

    2010-01-01

    Open thoraco-abdominal aortic aneurysm repair is a demanding procedure with high impact on the patient and the operating team. Results from expert centres show mortality rates between 3-21%, with extensive morbidity including renal failure and paraplegia. Endovascular repair of abdominal aortic aneu

  10. Some aspects of RNA repair and editing

    Directory of Open Access Journals (Sweden)

    Kovalchuk M. V.

    2010-11-01

    Full Text Available All cellular RNA molecules are damaged at the scale of DNA molecules, or even more. In the present review the RNA damaging agents, some mechanisms of RNA repair and editing, their difference from DNA repair mechanisms have been discussed.

  11. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature.

  12. Plan Repair using a Plan Library

    NARCIS (Netherlands)

    Van der Krogt, R.P.J.; De Weerdt, M.M.

    2005-01-01

    Plan library's have proven their added value to the efficiency of planning. In this paper, we present results on the use of a plan library to plan repair. We show that using a relatively simple library, we can already obtain significant improvements in efficiency compared to plan repair without a li

  13. Dysphagia in children with repaired oesophageal atresia

    NARCIS (Netherlands)

    Coppens, C.H.; Engel-Hoek, L. van den; Scharbatke, H.E.; Groot, S.A. de; Draaisma, J.M.T.

    2016-01-01

    Dysphagia is a common problem in children with repaired oesophageal atresia (OA). Abnormalities in the oropharyngeal and oesophageal phase have hardly been studied. The aims of this study were to assess the prevalence of dysphagia in children with repaired OA and to identify and differentiate oral

  14. Targeted gene repair – in the arena

    OpenAIRE

    2003-01-01

    The development of targeted gene repair is under way and, despite some setbacks, shows promise as an alternative form of gene therapy. This approach uses synthetic DNA molecules to activate and direct the cell’s inherent DNA repair systems to correct inborn errors. The progress of this technique and its therapeutic potential are discussed in relation to the treatment of genetic diseases.

  15. Other-initiated repair in Siwu

    Directory of Open Access Journals (Sweden)

    Dingemanse Mark

    2015-02-01

    Full Text Available This article describes the interactional patterns and linguistic structures associated with other-initiated repair in Siwu, a Kwa language spoken in eastern Ghana. Other-initiated repair is the set of techniques used by people to deal with problems in speaking, hearing and understanding. Formats for repair initiation in Siwu exploit language-specific resources like question words and noun class morphology. At the same time, the basic structure of the system bears a strong similarity to other-initiated repair in other languages. Practices described for Siwu thus are potentially of broader relevance to the study of other-initiated repair. This article documents how different prosodic realisations of repair initiators may index social actions and features of the speech event; how two distinct roles of repetition in repair initiators are kept apart by features of turn design; and what kinds of items can be treated as ‘dispensable’ in resayings. By charting how other-initiated repair uses local linguistic resources and yet is shaped by interactional needs that transcend particular languages, this study contributes to the growing field of pragmatic typology: the study of systems of language use and the principles that shape them.

  16. The Organization of Second Language Classroom Repair.

    Science.gov (United States)

    Jung, Euen Hyuk (Sarah)

    1999-01-01

    Explores classroom pedagogy through a focus on classroom interaction. Takes ideas from conversation analysis as a foundation and starts to unravel some of the structures used for classroom pedagogy. Uses the notion of repair, but takes it one step further by understanding repair to be a pedagogical tool used in the English-as-a-Second-Language…

  17. Modelling in Optimal Inspection and Repair

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Rackwitz, R.; Faber, M.H.;

    1991-01-01

    A model for reliability based optimal inspection and repair strategies is described. The total expected costs in the lifetime is minimized with the number of inspections, the inspection times and efforts, the repair crack size limit and a design parameter as optimization variables. The equivalenc...

  18. Material Handling Equipment Evaluation for Crater Repair

    Science.gov (United States)

    2016-11-01

    material handling equipment with a reduced logistical footprint for use by crater repair teams in airfield damage repair (ADR) scenarios. A market ...compared to currently utilized material handling equipment. This report presents the results of the market survey and equipment evaluations. Results...1 1.2 Objective and scope

  19. Pain characteristics after laparoscopic inguinal hernia repair

    DEFF Research Database (Denmark)

    Tolver, Mette A; Strandfelt, Pernille; Rosenberg, Jacob;

    2011-01-01

    Previous studies have shown different pain characteristics in different types of laparoscopic operations, but pain pattern has not been studied in detail after laparoscopic inguinal hernia repair. To optimise preoperative patient information and postoperative analgesic treatment the present study...... investigated postoperative pain in terms of time course, pain intensity and individual pain components during the first 4 days after transabdominal preperitoneal hernia repair (TAPP)....

  20. DNA repair phenotype and dietary antioxidant supplementation

    DEFF Research Database (Denmark)

    Guarnieri, Serena; Loft, Steffen; Riso, Patrizia

    2008-01-01

    -release vitamin C tablets had increased DNA repair activity (27 (95 % CI 12, 41) % higher incision activity). These subjects also benefited from the supplementation by reduced levels of oxidised guanines in MNBC. In conclusion, nutritional status, DNA repair activity and DNA damage are linked, and beneficial...

  1. Repairs the added value of being wrong

    CERN Document Server

    Brandt, Patrick

    2013-01-01

    Grammatical structures connect systems of thought and articulation, the conditions of which hardly seem to fit each other. Repairs are productive mechanisms that solve translation problems between modules or levels by adapting derivations or representations to requirements that have to be met unconditionally. Compensating for derivational and interpretive defects, repairs

  2. Repairing articular cartilage defects with tissue-engineering cartilage in rabbits

    Institute of Scientific and Technical Information of China (English)

    SONG Hong-xing; LI Fo-bao; SHEN Hui-liang; LIAO Wei-ming; LIU Miao; WANG Min; CAO Jun-ling

    2006-01-01

    Objective: To investigate the effect of cancellous bone matrix gelatin (BMG) engineered with allogeneic chondrocytes in repairing articular cartilage defects in rabbits.Methods: Chondrocytes were seeded onto three-dimensional cancellous BMG and cultured in vitro for 12 days to prepare BMG-chondrocyte complexes. Under anesthesia with 2.5% pentobarbital sodium (1 ml/kg body weight), articular cartilage defects were made on the right knee joints of 38 healthy New Zealand white rabbits (regardless of sex, aged 4-5 months and weighing 2.5-3 kg) and the defects were then treated with 2.5 % trypsin.Then BMG-chondrocyte complex (Group A, n=18 ),BMG ( Group B, n=10), and nothing ( Group C, n=10)were implanted into the cartilage defects, respectively. The repairing effects were assessed by macroscopic, histologic,transmission electron microscopic (TEM) observation,immunohistochemical examination and in situ hybridization detection, respectively, at 2, 4, 8, 12 and 24 weeks after operation.Results: Cancellous BMG was degraded within 8 weeks after operation. In Group A, lymphocyte infiltration was observed around the graft. At 24 weeks after operation, the cartilage defects were repaired by cartilage tissues and the articular cartilage and subchondral bone were soundly healed. Proteoglycan and type Ⅱ collagen were detected in the matrix of the repaired tissues by Safranin-O staining and immunohistochemical staining,respectively. In situ hybridization proved gene expression of type Ⅱ collagen in the cytoplasm of chondrocytes in the repaired tissues. TEM observation showed that chondrocytes and cartilage matrix in repaired tissues were almost same as those in the normal articular cartilage. In Group B, the defects were repaired by cartilage-fibrous tissues. In Group C, the defects were repaired only by fibrous tissues.Conclusions : Cancellous BMG can be regarded as the natural cell scaffolds for cartilage tissue engineering.Articular cartilage defects can be repaired by

  3. Bankart repair versus Bankart repair plus remplissage: an in vitro biomechanical comparative study.

    Science.gov (United States)

    Grimberg, Jean; Diop, Amadou; Bou Ghosn, Rony; Ghosn, Rosny Bou; Lanari, Dimitri; Canonne, Adrien; Maurel, Nathalie

    2016-02-01

    To biomechanically compare Bankart lesion repair alone and Bankart lesion repair associated with infraspinatus capsulotenodesis described as «remplissage», in the treatment of combined Bankart and Hill-Sachs lesions. Seven pairs (right and left) of cadaveric shoulders have been tested, first without any lesion and then after performing a combined Bankart and Hill-Sachs lesions. For each pair, the specimens were then randomly assigned for Bankart lesion repair alone on one side or for Bankart lesion repair associated with remplissage on the other side. During tests, the shoulder was placed at 90° of abduction and at maximal external rotation, which value was recorded. A 50 N postero-anterior load was then applied to the proximal humerus, and the stiffness was calculated from the obtained load-displacement curve. Bankart and Hill-Sachs lesions significantly (p Bankart lesion repair alone did not restore stiffness to the level of intact, while adding the remplissage to the Bankart lesion repair did. External rotation was significantly increased after creation of the Bankart and Hill-Sachs lesion; Bankart repair restored the external rotation to the level of intact, while Bankart lesion repair associated with remplissage significantly decreased external rotation compared with intact and to Bankart lesion repair alone. In cadaveric shoulders with combined Bankart and Hill-Sachs lesions, Bankart lesion repair associated with remplissage restored intact joint stiffness contrary to Bankart lesion repair alone. This increase in stiffness was associated with a decrease in external rotation.

  4. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    a learning curve of about 50-100 cases and decreases chronic pain, but slightly increases the risk of serious complications compared with open mesh repairs. Therefore, a simpler kind of operation is needed. The ONSTEP technique is a possible solution to this problem. The objective of the present randomised......INTRODUCTION: The optimal repair of inguinal hernias remains controversial. It is recommended that an inguinal hernia be repaired using a mesh, either with a laparoscopic or an open approach. In Denmark, the laparoscopic approach is used in an increasing number of cases. The laparoscopic repair has...... clinical trial described in this protocol is to evaluate chronic pain after inguinal hernia repair using the ONSTEP method versus the laparoscopic approach. METHODS: This study is designed as a non-inferiority, two-arm, multicentre, randomised clinical trial, with a 1:1 allocation to ONSTEP or laparoscopic...

  5. Convalescence after laparoscopic inguinal hernia repair

    DEFF Research Database (Denmark)

    Tolver, Mette Astrup; Rosenberg, Jacob; Bisgaard, Thue

    2016-01-01

    BACKGROUND: Duration of convalescence after inguinal hernia repair is of major socio-economic interest and an often reported outcome measure. The primary aim was to perform a critical analysis of duration of convalescence from work and activity and secondary to identify risk factors for unexpected...... prolonged convalescence after laparoscopic inguinal hernia repair. METHODS: A qualitative systematic review was conducted. PubMed, Embase and the Cochrane database were searched for trials reporting convalescence after laparoscopic inguinal hernia repair in the period from January 1990 to January 2016...... factors for prolonged convalescence extending more than a few days after laparoscopic inguinal hernia repair. CONCLUSIONS: Patients should be recommended a duration of 1-2 days of convalescence after laparoscopic inguinal hernia repair. Short and non-restrictive recommendations may reduce duration...

  6. Imperfect repair and lifesaving in heterogeneous populations

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, Maxim [Department of Mathematical Statistics, University of the Free State, PO Box 339, 9300 Bloemfontein (South Africa) and Max Planck Institute for Demographic Research, Rostock (Germany)]. E-mail: FinkelM.SCl@mail.uovs.ac.za

    2007-12-15

    In this theoretical paper we generalize the notion of minimal repair to the heterogeneous case, when the lifetime distribution function can be modeled by continuous or a discrete mixture of distributions. The statistical (black box) minimal repair and the minimal repair based on information just before the failure of an object are considered. The corresponding failure (intensity) rate processes are defined and analyzed. Demographic lifesaving model is also considered: each life is saved (cured) with some probability (or equivalently a proportion of individuals who would have died are now resuscitated and given another chance). Those who are saved experience the statistical minimal repair. Both of these models are based on the Poisson or non-homogeneous Poisson processes of underlying events, which allow for considering heterogeneity. We also consider the new model of imperfect repair in the homogeneous case and present generalizations to the heterogeneous setting.

  7. Repair Development for a Composite Cryotank

    Science.gov (United States)

    Cox, Sarah B.; Danley, Susan E.; Caraccio, Anne J.; Cheshire, Brian C.; Sampson, Jeffrey W.; Taylor, Brian J.

    2014-01-01

    The Composite Cryotank Technologies and Demonstration Project is working to advance the technologies for composite cryogenic propellant tanks at diameters suitable for future heavy lift vehicles and other in-space applications. The main goals of the project are to reduce weight and cost. One aspect of this project has focused on damage evaluation and repair development. Test panels have been impacted, repaired, and tested. Several repair methods were used to compare their effectiveness at restoring the integrity of the composite. Panels were evaluated by nondestructive evaluations at several points during the process to assess the damage and repair. The testing performed and the results and conclusions from the nondestructive evaluations and the destructive testing will be discussed. These results will lead to further development of inspection techniques and repair methods.

  8. Contact Dermatitis In Automobile Repair workers

    Directory of Open Access Journals (Sweden)

    Joshi M P

    1997-01-01

    Full Text Available Automobile repair workers are at risk of developing skin morbidity including occupational dermatoses because of their exposure to mineral oils, petroleum products and its derivatives and lubricating oil. This cross- sectional study was carried out at Maharashtra State Road Transport Corporation workshops in Nagpur city to investigate prevalence of skin morbidity including contact dermatitis in automobile repair workers. The study included 288 (49.9% automobile repair workers 180 (31.3% workshop office staff and 109 (18.8% divisional office employees. Dermatitis was the commonest skin morbidity in all the study subjects and it was significantly more prevalent in automobile repair workers. Folliculitis was detected in 13.2% of auto â€" repair workers and was not seen in the other two groups. Increasing trend of skin morbidity was correlated with the length of service of employees. Proper protective measures along with suitable washing facilities should be provided

  9. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    INTRODUCTION: The optimal repair of inguinal hernias remains controversial. It is recommended that an inguinal hernia be repaired using a mesh, either with a laparoscopic or an open approach. In Denmark, the laparoscopic approach is used in an increasing number of cases. The laparoscopic repair has...... a learning curve of about 50-100 cases and decreases chronic pain, but slightly increases the risk of serious complications compared with open mesh repairs. Therefore, a simpler kind of operation is needed. The ONSTEP technique is a possible solution to this problem. The objective of the present randomised...... clinical trial described in this protocol is to evaluate chronic pain after inguinal hernia repair using the ONSTEP method versus the laparoscopic approach. METHODS: This study is designed as a non-inferiority, two-arm, multicentre, randomised clinical trial, with a 1:1 allocation to ONSTEP or laparoscopic...

  10. Chromatin structure and DNA damage repair

    Directory of Open Access Journals (Sweden)

    Dinant Christoffel

    2008-11-01

    Full Text Available Abstract The integrity of the genome is continuously challenged by both endogenous and exogenous DNA damaging agents. These damaging agents can induce a wide variety of lesions in the DNA, such as double strand breaks, single strand breaks, oxidative lesions and pyrimidine dimers. The cell has evolved intricate DNA damage response mechanisms to counteract the genotoxic effects of these lesions. The two main features of the DNA damage response mechanisms are cell-cycle checkpoint activation and, at the heart of the response, DNA repair. For both damage signalling and repair, chromatin remodelling is most likely a prerequisite. Here, we discuss current knowledge on chromatin remodelling with respect to the cellular response to DNA damage, with emphasis on the response to lesions resolved by nucleotide excision repair. We will discuss the role of histone modifications as well as their displacement or exchange in nucleotide excision repair and make a comparison with their requirement in transcription and double strand break repair.

  11. Stochastic Modelling Of The Repairable System

    Directory of Open Access Journals (Sweden)

    Andrzejczak Karol

    2015-11-01

    Full Text Available All reliability models consisting of random time factors form stochastic processes. In this paper we recall the definitions of the most common point processes which are used for modelling of repairable systems. Particularly this paper presents stochastic processes as examples of reliability systems for the support of the maintenance related decisions. We consider the simplest one-unit system with a negligible repair or replacement time, i.e., the unit is operating and is repaired or replaced at failure, where the time required for repair and replacement is negligible. When the repair or replacement is completed, the unit becomes as good as new and resumes operation. The stochastic modelling of recoverable systems constitutes an excellent method of supporting maintenance related decision-making processes and enables their more rational use.

  12. Instrument repair for remote eye units

    Directory of Open Access Journals (Sweden)

    Sam Powdrill

    2004-10-01

    Full Text Available Many skilled eye surgeons in remote hospitals face the frustration that a simple instrument, once in good working order, is now bent or broken. Many eye units have a box containing instruments needing repair, hidden away in a stock room cupboard, in the hope that someone, someday, will be able to redeem them. This article gives guidelines on: 1 How to assess instruments and identify those that can be repaired locally, those that should be sent to a professional repair service and those that cannot be repaired at all. 2 How to make adjustments and carry out basic maintenance and repairs of surgical instruments. The article will refer primarily to instruments in an extracapsular cataract extraction set.

  13. Demonstration of blind quantum computing.

    Science.gov (United States)

    Barz, Stefanie; Kashefi, Elham; Broadbent, Anne; Fitzsimons, Joseph F; Zeilinger, Anton; Walther, Philip

    2012-01-20

    Quantum computers, besides offering substantial computational speedups, are also expected to preserve the privacy of a computation. We present an experimental demonstration of blind quantum computing in which the input, computation, and output all remain unknown to the computer. We exploit the conceptual framework of measurement-based quantum computation that enables a client to delegate a computation to a quantum server. Various blind delegated computations, including one- and two-qubit gates and the Deutsch and Grover quantum algorithms, are demonstrated. The client only needs to be able to prepare and transmit individual photonic qubits. Our demonstration is crucial for unconditionally secure quantum cloud computing and might become a key ingredient for real-life applications, especially when considering the challenges of making powerful quantum computers widely available.

  14. Characterization of ventral incisional hernia and repair using shear wave elastography.

    Science.gov (United States)

    Chaudhry, Anuj; Fernandez-Moure, Joseph S; Shajudeen, Peer Shafeeq; Van Eps, Jeffrey L; Cabrera, Fernando J; Weiner, Bradley K; Dunkin, Brian J; Tasciotti, Ennio; Righetti, Raffaella

    2017-04-01

    To assess the integrity of hernia repair, imaging modalities such as computed tomography or ultrasound (US) are commonly used. Neither modality has currently the capacity to simultaneously image the mesh and quantify a prosthetic and surrounding tissue stiffness. In this pilot study, we hypothesize that US shear wave elastography (SWE) can be used to identify a polyester mesh and a biologic graft and to assess their stiffness noninvasively in a rat model of bridging hernia repair. Lewis rats underwent hernia creation and repair with Parietex or Strattice at 30 d. After 3 mo, the animals were euthanized, and the Young's Modulus was measured using SWE. Three-dimensional reconstructions of the hernia pre- and post-repair were performed using in-house image processing algorithms. SWE was capable of accurate and real-time assessment and diagnosis of the hernia defects in vivo. Young's Modulus of Parietex meshes and Strattice grafts as estimated from the shear wave elastograms were found to be statistically different from each other (P < 0.05). Accurate three-dimensional reconstructions of the hernia defects pre- and post-repair were generated. In this study, we demonstrate the feasibility of using US SWE to detect ventral hernias and evaluate mesh repair in vivo. Our results indicate that the presence of a hernia and repair can be reliably visualized by SWE and three dimensionally reconstructed. Thus, this technique may provide both structural and functional information regarding the hernia and the repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. How Prepared is Prepared Enough?

    Science.gov (United States)

    Porter-Levy; Macleod; Rickert

    1996-10-01

    A 17-year-old female was in the final stage in treatment of right unilateral cleft lip and palate. She had undergone a number of previous surgeries. Hearing and speech were good on evaluation, and her social and family situation were deemed excellent. After preparatory orthodontics she underwent a Lefort I maxillary advancement. Surgery was successful and she was admitted into postoperative recovery. However, the lack of adequate preoperative preparation caused traumatic reaction from the patient and her parents: anxiety over appearance, crying, refusal of oral fluids and oral care, refusal of analgesia, and refusal to mobilize. The patience and persistence of hospital staff slowly overcame all adversities and the patient moved on to full and successful recovery, but this case prompted changes in preoperative procedures and involvement of patients and their families in postoperative meal selection, planing, and preparation.

  16. Systems Maintenance Automated Repair Tasks (SMART)

    Science.gov (United States)

    Schuh, Joseph; Mitchell, Brent; Locklear, Louis; Belson, Martin A.; Al-Shihabi, Mary Jo Y.; King, Nadean; Norena, Elkin; Hardin, Derek

    2010-01-01

    SMART is a uniform automated discrepancy analysis and repair-authoring platform that improves technical accuracy and timely delivery of repair procedures for a given discrepancy (see figure a). SMART will minimize data errors, create uniform repair processes, and enhance the existing knowledge base of engineering repair processes. This innovation is the first tool developed that links the hardware specification requirements with the actual repair methods, sequences, and required equipment. SMART is flexibly designed to be useable by multiple engineering groups requiring decision analysis, and by any work authorization and disposition platform (see figure b). The organizational logic creates the link between specification requirements of the hardware, and specific procedures required to repair discrepancies. The first segment in the SMART process uses a decision analysis tree to define all the permutations between component/ subcomponent/discrepancy/repair on the hardware. The second segment uses a repair matrix to define what the steps and sequences are for any repair defined in the decision tree. This segment also allows for the selection of specific steps from multivariable steps. SMART will also be able to interface with outside databases and to store information from them to be inserted into the repair-procedure document. Some of the steps will be identified as optional, and would only be used based on the location and the current configuration of the hardware. The output from this analysis would be sent to a work authoring system in the form of a predefined sequence of steps containing required actions, tools, parts, materials, certifications, and specific requirements controlling quality, functional requirements, and limitations.

  17. INTERNAL REPAIR OF PIPELINES REVIEW & EVALUATION OF INTERNAL PIPELINE REPAIR TRIALS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-09-01

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners, indicating that this type of liner is generally ineffective at restoring the pressure containing capabilities of pipelines. Failure pressure for pipe repaired with carbon fiber-reinforced composite liner was greater than that of the un-repaired pipe section with damage, indicating that this type of liner is effective at restoring the pressure containing capability of pipe. Pipe repaired with weld deposition failed at pressures lower than that of un-repaired pipe in both the virgin and damaged conditions, indicating that this repair technology is less effective at restoring the pressure containing capability of pipe than a carbon fiber-reinforced liner repair. Physical testing indicates that carbon fiber-reinforced liner repair is the most promising technology evaluated to-date. Development of a comprehensive test plan for this process is recommended for use in the next phase of this project.

  18. Laparoscopic repair of vesicovaginal fistula

    Directory of Open Access Journals (Sweden)

    Miłosz Wilczyński

    2011-06-01

    Full Text Available A vesicovaginal fistula is one of the complications that a gynaecologist is bound to face after oncological operations, especially in postmenopausal women. Over the years there have been introduced many techniques of surgical treatment of this entity, including transabdominal and transvaginal approaches.We present a case of a 46-year-old patient who suffered from urinary leakage via the vagina due to the presence of a vesicovaginal fistula that developed after radical abdominal hysterectomy and subsequent radiotherapy. The decision was made to repair it laparoscopically due to retracted, fibrous and scarred tissue in the vaginal apex that precluded a transvaginal approach. A small cystotomy followed by an excision of fistula borders was performed. After six-month follow-up no recurrence of the disease has been noted.We conclude that laparoscopy is an interesting alternative to traditional approaches that provides comparable results.

  19. [SOS-repair--60 years].

    Science.gov (United States)

    Zavil'gel'skiĭ, G B

    2013-01-01

    This review integrates 60 years of research on SOS-repair and SOS-mutagenesis in procaryotes and eucaryotes, from Jean Weigle experiment in 1953 year (mutagenesis of lambda bacteriophage in UV-irradiated bacteria) to the latest achievements in studying SOS-mutagenesis on all living organisms--Eukarya, Archaea and Bacteria. A key role in establishing of a biochemical basis for SOS-mutagenesis belonges to the finding in 1998-1999 years that specific error-prone DNA polymerases (PolV and others) catalysed translesion synthesis on damaged DNA. This review focuses on recent studies addressing the new models for SOS-induced mutagenesis in Escherichia coli and Home sapiens cells.

  20. Suturing property of tough double network hydrogels for bio-repair materials

    Science.gov (United States)

    Na, Yang Ho; Oh, Hwa Yeon; Ahn, Young Ju; Han, Youngbae

    2015-02-01

    Cartilage and meniscal lesions have limited potential for spontaneous repair. Consequently, much effort has been made to develop methods for repairing such lesions. Double-network (DN) gels are new candidate-materials for repairing such lesions. They exhibit exceptional mechanical strength and toughness in spite of their high water content. In this study, we prepared highly tough DN hydrogels and investigated the mechanical properties related to clinical implant use. The mechanical properties such as Young's modulus and suture tear-out strength were measured for the artificial replacement. The results suggest that the suture property of DN hydrogels can be adjusted by controlling the crosslinking density and monomer concentration. Finite element method was also applied to these DN hydrogels in order to check whether the fracture strength of the material is enough to meet a medical purpose.

  1. Shuttle Repair Tools Automate Vehicle Maintenance

    Science.gov (United States)

    2013-01-01

    Successfully building, flying, and maintaining the space shuttles was an immensely complex job that required a high level of detailed, precise engineering. After each shuttle landed, it entered a maintenance, repair, and overhaul (MRO) phase. Each system was thoroughly checked and tested, and worn or damaged parts replaced, before the shuttle was rolled out for its next mission. During the MRO period, workers needed to record exactly what needed replacing and why, as well as follow precise guidelines and procedures in making their repairs. That meant traceability, and with it lots of paperwork. In 2007, the number of reports generated during electrical system repairs was getting out of hand-placing among the top three systems in terms of paperwork volume. Repair specialists at Kennedy Space Center were unhappy spending so much time at a desk and so little time actually working on the shuttle. "Engineers weren't spending their time doing technical work," says Joseph Schuh, an electrical engineer at Kennedy. "Instead, they were busy with repetitive, time-consuming processes that, while important in their own right, provided a low return on time invested." The strain of such inefficiency was bad enough that slow electrical repairs jeopardized rollout on several occasions. Knowing there had to be a way to streamline operations, Kennedy asked Martin Belson, a project manager with 30 years experience as an aerospace contractor, to co-lead a team in developing software that would reduce the effort required to document shuttle repairs. The result was System Maintenance Automated Repair Tasks (SMART) software. SMART is a tool for aggregating and applying information on every aspect of repairs, from procedures and instructions to a vehicle s troubleshooting history. Drawing on that data, SMART largely automates the processes of generating repair instructions and post-repair paperwork. In the case of the space shuttle, this meant that SMART had 30 years worth of operations

  2. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  3. Endovascular Repair of a Ruptured Aortic Extra-anatomic Bypass Pseudoaneurysm After Previous Coarctation Surgery.

    Science.gov (United States)

    Hörer, Tal; Toivola, Asko

    2015-01-01

    We present a short case of a total endovascular repair of a ruptured thoracic pseudoaneurysm after previous coarctation aortic conduit bypass surgery. A 67-year-old man with two previous coarctation repairs many years ago was admitted with chest pain, dyspnea, and hemoptysis. Computed tomography showed a rupture in the distal anastomosis of the thoracic extra-anatomic graft. Successful treatment was achieved by placement of an endovascular stent graft between the old graft and the native aorta and with a vascular plug occlusion of the native aorta.

  4. Hybrid Thoracic Endovascular Aortic Repair for Intercostal Patch Aneurysm after Thoracoabdominal Aortic Replacement.

    Science.gov (United States)

    Kitahara, Hiroto; Yoshitake, Akihiro; Hachiya, Takashi; Okamoto, Kazuma; Hirano, Akinori; Kasai, Mio; Akamatsu, Yuta; Oka, Hidetoshi; Shimizu, Hideyuki

    2015-01-01

    We report a case of hybrid thoracic endovascular aortic repair for intercostal patch aneurysm after thoracoabdominal aortic replacement. Eighteen years ago, a 63-year-old woman with Marfan syndrome had undergone thoracoabdominal aortic replacement with reimplantation of the intercostal artery in an island fashion. Follow-up computed tomography (CT) revealed a remaining intercostal patch aneurysm of diameter 60 mm 17 years after the last operation. Hybrid thoracic endovascular aortic repair for exclusion of this intercostal patch aneurysm was successfully performed, with visceral artery bypasses. Postoperative CT showed no anastomotic stenosis or endoleak.

  5. Is Early Nasal Shaping With a Limited Alar Base Incision Possible in the Repair of Cleft Lips?

    Science.gov (United States)

    Kapi, Emin; Bozkurt, Mehmet; Ozer, Torun; Celik, Mehmet Yusuf

    2016-05-01

    The repair of cleft lips has an important place in plastic and reconstructive surgery. In the treatment of these deformities, the aim was to restore the normal lip morphology in the cleft area as well as repairing any coexisting nasal deformities. Various methods are in use for this purpose. One of the most commonly employed surgical methods is Millard repair. However, this method may lead to additional scarring in the alar base on the cleft side subsequent to the incision. In this study, the results obtained from a group who have been applied alar base incisions during the modified Millard repair are compared to a group who have undergone intranasal wide dissections.The patients enrolled in the study were randomized into 2 groups. The first group were applied the modified Millard repair. In the second group, the rotation, advancement, and C-flaps were prepared according to Millard surgical repair technique; however, instead of an alar base and nasofacial groove incision on the cleft side, a nasal and maxillary supraperiosteal wide dissection was made through the incision in the mucosa of the nostril.The intranasal dissection performed during the study was observed to provide the targeted outcome and a more satisfactory cosmetic result through the modified Millard repair. In conclusion, the authors are of the opinion that the limited alar base incision and the wide supraperiosteal dissection performed in patients with cleft lips is an alternative method that can be employed in a wide range of patients.

  6. Innovation and rationalization of production processes by introduction of computer and information technology. Unapredjenje i racionalizacija proizvodnih procesa uvodjenjem racunarskih informacionih tehnologija

    Energy Technology Data Exchange (ETDEWEB)

    Vujic, S. (Rudarsko-Geoloski Fakultet, Belgrade (Yugoslavia))

    1990-01-01

    Discusses the importance of modern computer and information technology in the mining industry, geology and metallurgy in Yugoslavia. Wide application of this technology is required for rationalization and modernization of production processes. A description of the computerized information and monitoring system of the Kennecott Minerals Co. in Salt Lake City (USA) is made. The network center of the system monitors management of a power plant, surface mines, ore preparation plant, flotation plant as well as smelting and refining plant. The computer-aided management system in an ore surface mine is further outlined. It deals primarily with computer-assisted maintenance and repair of mining equipment. The Kennecott computerized management system is recommended for Yugoslav coal and ore mining enterprises. 6 refs.

  7. Collagen/silk fibroin composite scaffold incorporated with PLGA microsphere for cartilage repair

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jianhua; Yang, Qiu; Cheng, Niangmei [Institute of Biomedical and Pharmaceutical Technology, Fuzhou University, Fuzhou 350002 (China); Tao, Xiaojun [Department of Pharmacy, School of Medicine, Hunan Normal University, Changsha, 410013, Hunan (China); Zhang, Zhihua; Sun, Xiaomin [Institute of Biomedical and Pharmaceutical Technology, Fuzhou University, Fuzhou 350002 (China); Zhang, Qiqing, E-mail: zhangqiq@126.com [Institute of Biomedical and Pharmaceutical Technology, Fuzhou University, Fuzhou 350002 (China); Key Laboratory of Biomedical Materials of Tianjin, Institute of Biomedical Engineering, Chinese Academy of Medical Science & Peking Union Medical College, Tianjin 300192 (China)

    2016-04-01

    For cartilage repair, ideal scaffolds should mimic natural extracellular matrix (ECM) exhibiting excellent characteristics, such as biocompatibility, suitable porosity, and good cell affinity. This study aimed to prepare a collagen/silk fibroin composite scaffold incorporated with poly-lactic-co-glycolic acid (PLGA) microsphere that can be applied in repairing cartilage. To obtain optimum conditions for manufacturing a composite scaffold, a scaffold composed of different collagen-to-silk fibroin ratios was evaluated by determining porosity, water absorption, loss rate in hot water, and cell proliferation. Results suggested that the optimal ratio of collagen and silk fibroin composite scaffold was 7:3. The microstructure and morphological characteristics of the obtained scaffold were also examined through scanning electron microscopy and Fourier transform infrared spectroscopy. The results of in vitro fluorescence staining of bone marrow stromal cells revealed that collagen/silk fibroin composite scaffold enhanced cell proliferation without eliciting side effects. The prepared composite scaffold incorporated with PLGA microsphere was implanted in fully thick articular cartilage defects in rabbits. Collagen/silk fibroin composite scaffold with PLGA microspheres could enhance articular cartilage regeneration and integration between the repaired cartilage and the surrounding cartilage. Therefore, this composite will be a promising material for cartilage repair and regeneration. - Highlights: • Collagen/silk fibroin composite scaffold incorporated with PLGA microsphere proposed for cartilage repair was created. • In vivo, scaffold could enhance cartilage regeneration and integration between the repaired and surrounding cartilage. • In vitro, scaffold exhibits excellent characteristics, such as, improved porosity water absorption and good cell affinity.

  8. Management and outcomes of colovesical fistula repair.

    Science.gov (United States)

    Lynn, Elizabeth T; Ranasinghe, Nalin E; Dallas, Kai B; Divino, Celia M

    2012-05-01

    This large retrospective study presents the largest colovesical fistula (CVF) series to date. We report on recurrence risk factors and patient satisfaction based on quality of life after CVF repair. Approval was obtained from The Mount Sinai School of Medicine Institutional Review Board, and a retrospective review was performed from 2003 to 2010 involving 72 consecutive patients who underwent a colovesical fistula repair. The CVF recurrence rate was 11 per cent. Ten percent of our patients who had a history of radiation therapy were at a significantly higher risk of developing a recurrence. Noted recurrence rates were significantly higher in advanced bladder repairs compared with simple repair (P = 0.022). The modified (Gastrointestinal Quality of Life Index) surveys showed overall patient satisfaction score was 3.6, out of a maximum score of 4, regardless of the type of repair or any postoperative complications. Our study found the CVF recurrence rate to be 11 per cent. Patients at higher risk of recurrence include those needing advanced bladder repair, those with "complex" CVF, and those whose fistulas involve the urethra. Patient satisfaction was found to be more closely linked to the resolution of CVF symptoms, irrespective of the type of repair performed or development of postoperative complications.

  9. Arthroscopic Quadriceps Tendon Repair: Two Case Reports

    Directory of Open Access Journals (Sweden)

    Hidetomo Saito

    2015-01-01

    Full Text Available Recently, although some studies of open repair of the tendon of the quadriceps femoris have been published, there have been no reports in the literature on primary arthroscopic repair. In our present study, we present two cases of quadriceps tendon injury arthroscopically repaired with excellent results. Case 1 involved a 68-year-old man who was injured while shifting his weight to prevent a fall. MRI showed complete rupture at the insertion of the patella of the quadriceps tendon. The rupture was arthroscopically repaired using both suture anchor and pull-out suture fixation methods via bone tunnels (hereafter, pull-out fixation. Two years after surgery, retearing was not observed on MRI and both Japan Orthopedic Association (JOA Knee and Lysholm scores had recovered to 100. Case 2 involved a 50-year-old man who was also injured when shifting his weight to prevent a fall. MRI showed incomplete superficial rupture at the insertion of the patella of the quadriceps tendon. The rupture was arthroscopically repaired using pull-out fixation of six strand sutures. One year after surgery, MRI revealed a healed tendon and his JOA and Lysholm scores were 95 and 100, respectively. Thus, arthroscopic repair may be a useful surgical method for repairing quadriceps tendon injury.

  10. Arthroscopic quadriceps tendon repair: two case reports.

    Science.gov (United States)

    Saito, Hidetomo; Shimada, Yoichi; Yamamura, Toshiaki; Yamada, Shin; Sato, Takahiro; Nozaka, Koji; Kijima, Hiroaki; Saito, Kimio

    2015-01-01

    Recently, although some studies of open repair of the tendon of the quadriceps femoris have been published, there have been no reports in the literature on primary arthroscopic repair. In our present study, we present two cases of quadriceps tendon injury arthroscopically repaired with excellent results. Case 1 involved a 68-year-old man who was injured while shifting his weight to prevent a fall. MRI showed complete rupture at the insertion of the patella of the quadriceps tendon. The rupture was arthroscopically repaired using both suture anchor and pull-out suture fixation methods via bone tunnels (hereafter, pull-out fixation). Two years after surgery, retearing was not observed on MRI and both Japan Orthopedic Association (JOA) Knee and Lysholm scores had recovered to 100. Case 2 involved a 50-year-old man who was also injured when shifting his weight to prevent a fall. MRI showed incomplete superficial rupture at the insertion of the patella of the quadriceps tendon. The rupture was arthroscopically repaired using pull-out fixation of six strand sutures. One year after surgery, MRI revealed a healed tendon and his JOA and Lysholm scores were 95 and 100, respectively. Thus, arthroscopic repair may be a useful surgical method for repairing quadriceps tendon injury.

  11. Dental materials for cleft palate repair.

    Science.gov (United States)

    Sharif, Faiza; Ur Rehman, Ihtesham; Muhammad, Nawshad; MacNeil, Sheila

    2016-04-01

    Numerous bone and soft tissue grafting techniques are followed to repair cleft of lip and palate (CLP) defects. In addition to the gold standard surgical interventions involving the use of autogenous grafts, various allogenic and xenogenic graft materials are available for bone regeneration. In an attempt to discover minimally invasive and cost effective treatments for cleft repair, an exceptional growth in synthetic biomedical graft materials have occurred. This study gives an overview of the use of dental materials to repair cleft of lip and palate (CLP). The eligibility criteria for this review were case studies, clinical trials and retrospective studies on the use of various types of dental materials in surgical repair of cleft palate defects. Any data available on the surgical interventions to repair alveolar or palatal cleft, with natural or synthetic graft materials was included in this review. Those datasets with long term clinical follow-up results were referred to as particularly relevant. The results provide encouraging evidence in favor of dental and other related biomedical materials to fill the gaps in clefts of lip and palate. The review presents the various bones and soft tissue replacement strategies currently used, tested or explored for the repair of cleft defects. There was little available data on the use of synthetic materials in cleft repair which was a limitation of this study. In conclusion although clinical trials on the use of synthetic materials are currently underway the uses of autologous implants are the preferred treatment methods to date.

  12. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  13. Successful Use of Targeted Temperature Management After Repair of Myocardial Rupture from Blunt Chest Trauma: A Case Report.

    Science.gov (United States)

    Choi, Wook-Jin; Kim, Yun Seok; Hong, Jung Seok; Kim, Jeong Won

    2017-03-01

    Targeted temperature management (TTM) improves survival and neurological outcome after nontraumatic cardiac arrest. However, TTM is not used widely after traumatic cardiac arrest because of concerns that it might exacerbate bleeding. We report the use of postarrest TTM after repair of blunt myocardial rupture. A 48-year-old man was admitted after being rescued from a major traffic accident by the local emergency service. Focused sonography showed pericardial fluid without cardiac tamponade. Computed tomography showed a large hematoma in the anterior mediastinum associated with hemopericardium. The patient developed cardiac arrest during the operative preparations. Repeat bedside sonography revealed a large pericardial effusion and signs of cardiac tamponade. Spontaneous circulation was restored after ultrasound-guided pericardiocentesis. His Glasgow Coma Scale score was 3. The patient was transported promptly to the operating room and underwent median sternotomy without cardiopulmonary bypass. A rupture of the junction of the superior vena cava/right atrium and left atrial appendage was detected and was closed by direct suturing. Immediately after return to the intensive care unit, we performed TTM (target body temperature 34.5°C) using a surface-cooling device at 4 hours postarrest. TTM was maintained for 24 hours and controlled gradual rewarming was then initiated. He regained consciousness 36 hours postrewarming with limited speech ability. The patient recovered with no further cardiac events and was discharged 3 weeks after admission, with no other serious complications. The patient was neurologically intact (cerebral performance category 1) at 6 months of follow-up. This case demonstrates the potential benefit and applicability of postarrest TTM in patients after repair of blunt myocardial rupture.

  14. Diverless pipeline repair system for deep water

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Carlo M. [Eni Gas and Power, Milan (Italy); Fabbri, Sergio; Bachetta, Giuseppe [Saipem/SES, Venice (Italy)

    2009-07-01

    SiRCoS (Sistema Riparazione Condotte Sottomarine) is a diverless pipeline repair system composed of a suite of tools to perform a reliable subsea pipeline repair intervention in deep and ultra deep water which has been on the ground of the long lasting experience of Eni and Saipem in designing, laying and operating deep water pipelines. The key element of SiRCoS is a Connection System comprising two end connectors and a repair spool piece to replace a damaged pipeline section. A Repair Clamp with elastomeric seals is also available for pipe local damages. The Connection System is based on pipe cold forging process, consisting in swaging the pipe inside connectors with suitable profile, by using high pressure seawater. Three swaging operations have to be performed to replace the damaged pipe length. This technology has been developed through extensive theoretical work and laboratory testing, ending in a Type Approval by DNV over pipe sizes ranging from 20 inches to 48 inches OD. A complete SiRCoS system has been realised for the Green Stream pipeline, thoroughly tested in workshop as well as in shallow water and is now ready, in the event of an emergency situation.The key functional requirements for the system are: diverless repair intervention and fully piggability after repair. Eni owns this technology and is now available to other operators under Repair Club arrangement providing stand-by repair services carried out by Saipem Energy Services. The paper gives a description of the main features of the Repair System as well as an insight into the technological developments on pipe cold forging reliability and long term duration evaluation. (author)

  15. Repair of 8-methoxypsoralen monoadducts and diadducts in bacteriophages and bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Belogurov, A.A.; Zuev, A.V.; Zavil' gel' skii, G.B.

    1976-01-01

    The combined action of 8-methoxypsoralen (8-MOP) and light with lambda greater than 310 nm on bacteriophages and bacteria results in the formation of the following two types of photo-products in the DNA: monoadducts, in which 8-MOP is covalently bound to a pyrimidine base, and diadducts or cross links, in which 8-MOP is covalently bound to two pyrimidines from complementary strands. The method of repeated irradiation has been proposed for analyzing the degree of lethality of the photoproducts in DNA. According to this method, the preparation is freed of free 8-MOP molecules after the first irradiation and then irradiated for a second time. In this case the monoadducts are converted into cross linkages between the strands. Approximately 3-10(-9) cross links/Dalton-min form in Escherichia coli DNA during the first irradiation. The rate of the formation of cross links drops by a factor of about 2 during the repeated irradiation. It has been shown that the 8-MOP monoadducts are repaired by the uvr system just as efficiently as are lethal photoproducts of the cyclobutane pyrimidine dimer type. Lethal cross linkages in bacteria and phages are repaired by the joint action of the uvr, recA, and lex systems. A scheme has been proposed for the repair of cross linkages in one genome by these systems. The photoreactivating enzyme is inactive on DNA subjected to the combined action of 8-MOP and light. The kinetics of the repair of monadducts in bacteria and phages with various defects in the repair systems have been studied. It has been shown that the products of genes recA and lex take part in the repair process according to an excision-resynthesis method. The use of the method of repeated irradiation with 8-MOP as an express method for detecting repair systems of the uvr type in cells has been proposed.

  16. DNA Double Strand Break Response and Limited Repair Capacity in Mouse Elongated Spermatids

    Directory of Open Access Journals (Sweden)

    Emad A. Ahmed

    2015-12-01

    Full Text Available Spermatids are extremely sensitive to genotoxic exposures since during spermiogenesis only error-prone non homologous end joining (NHEJ repair pathways are available. Hence, genomic damage may accumulate in sperm and be transmitted to the zygote. Indirect, delayed DNA fragmentation and lesions associated with apoptotic-like processes have been observed during spermatid elongation, 27 days after irradiation. The proliferating spermatogonia and early meiotic prophase cells have been suggested to retain a memory of a radiation insult leading later to this delayed fragmentation. Here, we used meiotic spread preparations to localize phosphorylate histone H2 variant (γ-H2AX foci marking DNA double strand breaks (DSBs in elongated spermatids. This technique enabled us to determine the background level of DSB foci in elongated spermatids of RAD54/RAD54B double knockout (dko mice, severe combined immunodeficiency SCID mice, and poly adenosine diphosphate (ADP-ribose polymerase 1 (PARP1 inhibitor (DPQ-treated mice to compare them with the appropriate wild type controls. The repair kinetics data and the protein expression patterns observed indicate that the conventional NHEJ repair pathway is not available for elongated spermatids to repair the programmed and the IR-induced DSBs, reflecting the limited repair capacity of these cells. However, although elongated spermatids express the proteins of the alternative NHEJ, PARP1-inhibition had no effect on the repair kinetics after IR, suggesting that DNA damage may be passed onto sperm. Finally, our genetic mutant analysis suggests that an incomplete or defective meiotic recombinational repair of Spo11-induced DSBs may lead to a carry-over of the DSB damage or induce a delayed nuclear fragmentation during the sensitive programmed chromatin remodeling occurring in elongated spermatids.

  17. Patching Broken DNA: Nucleosome Dynamics and the Repair of DNA Breaks.

    Science.gov (United States)

    Gursoy-Yuzugullu, Ozge; House, Nealia; Price, Brendan D

    2016-05-08

    The ability of cells to detect and repair DNA double-strand breaks (DSBs) is dependent on reorganization of the surrounding chromatin structure by chromatin remodeling complexes. These complexes promote access to the site of DNA damage, facilitate processing of the damaged DNA and, importantly, are essential to repackage the repaired DNA. Here, we will review the chromatin remodeling steps that occur immediately after DSB production and that prepare the damaged chromatin template for processing by the DSB repair machinery. DSBs promote rapid accumulation of repressive complexes, including HP1, the NuRD complex, H2A.Z and histone methyltransferases at the DSB. This shift to a repressive chromatin organization may be important to inhibit local transcription and limit mobility of the break and to maintain the DNA ends in close contact. Subsequently, the repressive chromatin is rapidly dismantled through a mechanism involving dynamic exchange of the histone variant H2A.Z. H2A.Z removal at DSBs alters the acidic patch on the nucleosome surface, promoting acetylation of the H4 tail (by the NuA4-Tip60 complex) and shifting the chromatin to a more open structure. Further, H2A.Z removal promotes chromatin ubiquitination and recruitment of additional DSB repair proteins to the break. Modulation of the nucleosome surface and nucleosome function during DSB repair therefore plays a vital role in processing of DNA breaks. Further, the nucleosome surface may function as a central hub during DSB repair, directing specific patterns of histone modification, recruiting DNA repair proteins and modulating chromatin packing during processing of the damaged DNA template.

  18. Chronic pain after childhood groin hernia repair

    DEFF Research Database (Denmark)

    Aasvang, Eske Kvanner; Kehlet, Henrik

    2007-01-01

    BACKGROUND: In contrast to the well-described 10% risk of chronic pain affecting daily activities after adult groin hernia repair, chronic pain after childhood groin hernia repair has never been investigated. Studies of other childhood surgery before the age of 3 months suggest a risk of increased...... pain responsiveness later in life, but its potential relationship to chronic pain in adult life is unknown. METHODS: This was a nationwide detailed questionnaire study of chronic groin pain in adults having surgery for a groin hernia repair before the age of 5 years (n = 1075). RESULTS: The response...

  19. Repair of umbilical and epigastric hernias.

    Science.gov (United States)

    Earle, David B; McLellan, Jennifer A

    2013-10-01

    Umbilical and epigastric hernias are primary midline defects that are present in up to 50% of the population. In the United States, only about 1% of the population carries this specific diagnosis, and only about 11% of these are repaired. Repair is aimed at symptoms relief or prevention, and the patient's goals and expectations should be explicitly identified and aligned with the health care team. This article details some relevant and interesting anatomic issues, reviews existing data, and highlights some common and important surgical techniques. Emphasis is placed on a patient-centered approach to the repair of umbilical and epigastric hernias.

  20. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......Background For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. Data sources...

  1. Repair of Electronics for Long Duration Spaceflight

    Science.gov (United States)

    Pettegrew, Richard D.; Easton, John; Struk, Peter

    2007-01-01

    To reduce mission risk, long duration spaceflight and exploration activities will require greater degrees of self-sufficiency with regards to repair capability than have ever been employed before in space exploration. The current repair paradigm of replacing Orbital Replacement Units (ORUs) of malfunctioning avionics and electronic hardware will be impractical, since carrying all of the spares that could possibly be needed for a long duration mission would require upmass and volume at unprecedented and unacceptable levels. A strategy of component-level repair for electronics, however, could significantly reduce the mass and volume necessary for spares and enhance mission safety via a generic contingency capability. This approach is already used to varying degrees by the U.S. Navy, where vessels at sea experience some similar constraints such as the need for self sufficiency for moderately long time periods, and restrictions on volume of repair spares and infrastructure. The concept of conducting component-level repairs of electronics in spacecraft requires the development of design guidelines for future avionics (to enable repair), development of diagnostic techniques to allow an astronaut to pinpoint the faulty component aboard a vastly complex vehicle, and development of tools and methodologies for dealing with the physical processes of replacing the component. This physical process includes tasks such as conformal coating removal and replacement, component removal, replacement, and alignment--all in the difficulty of a reduced gravity environment. Further, the gravitational effects on the soldering process must be characterized and accounted for to ensure reliability of the newly repaired components. The Component-Level Electronics-Assembly Repair (CLEAR) project under the NASA Supportability program was established to develop and demonstrate the practicality of this repair approach. CLEAR involves collaborative efforts between NASA s Glenn Research Center

  2. Method of repairing discontinuity in fiberglass structures

    Science.gov (United States)

    Gelb, L. L.; Helbert, W. B., Jr.; Enie, R. B.; Mulliken, R. F. (Inventor)

    1974-01-01

    Damaged fiberglass structures are repaired by substantially filling the irregular surfaced damaged area with a liquid, self-curing resin, preferably an epoxy resin mixed with chopped fiberglass, and then applying to the resin surface the first of several woven fiberglass swatches which has stitching in a zig-zag pattern parallel to each of its edges and a fringe of warp and fill glass fibers about the edges outward of the stitching. The method is especially applicable to repair of fiberglass rocket engine casings and is particularly advantageous since it restores the repaired fiberglass structure to substantially its original strength without any significant changes in the geometry or mass of the structure.

  3. LHC Report: Restart preparations continue

    CERN Multimedia

    Katy Foraz for the LHC team and Julia Trummer for the RP Group

    2012-01-01

    Maintenance and consolidation work has been progressing well in both the machine and the experiments in preparation for the March restart.   A sample material is attached to the LHC (the white bag taped to the green line), to measure the radiation doses. Additional work was required around Point 5 due to the discovery and repair of a problem with the RF fingers at the connection of two beam vacuum chambers in CMS. The repair has been completed successfully and the sector is now under vacuum. In order to avoid rushing the delicate final operations required for closing the detector, the restart of the machine has been postponed by one week, from 7 March to 14 March. In the machine, the first cool-down to 1.9 K has started in several sectors ,and the cool-down of the whole machine is still planned to be finished by 21 February. The time window between 22 February and 14 March will be dedicated to powering and cryogenic tests. Since 12 December, the Radiation Protection (RP) group has been deep...

  4. Development of bonded composite doublers for the repair of oil recovery equipment.

    Energy Technology Data Exchange (ETDEWEB)

    Roach, David W.; Rackow, Kirk A.

    2005-06-01

    structures. This study developed and proved an optimum field installation process using specific mechanical and chemical surface preparation techniques coupled with unique, in-situ heating methods. In addition, a comprehensive performance assessment of composite doubler repairs was completed to establish the viability of this technology for large, steel structures. The factors influencing the durability of composite patches in severe field environments were evaluated along with related laminate design issues.

  5. INTERNAL REPAIR OF GAS PIPLINES SURVEY OF OPERATOR EXPERIENCE AND INDUSTRY NEEDS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Ian D. Harris

    2003-09-01

    A repair method that can be applied from the inside of a gas transmission pipeline (i.e., a trenchless repair) is an attractive alternative to conventional repair methods since the need to excavate the pipeline is precluded. This is particularly true for pipelines in environmentally sensitive and highly populated areas. The objectives of the project are to evaluate, develop, demonstrate, and validate internal repair methods for pipelines; develop a functional specification for an internal pipeline repair system; and prepare a recommended practice for internal repair of pipelines. The purpose of this survey is to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. A total of fifty-six surveys were sent to pipeline operators. A total of twenty completed surveys were returned, representing a 36% response rate, which is considered very good given the fact that tailored surveys are known in the marketing industry to seldom attract more than a 10% response rate. The twenty survey responses produced the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water (e.g., lakes and swamps) in difficult soil conditions, under highways, under congested intersections, and under railway crossings. All these areas tend to be very difficult and very costly if, and where, conventional excavated repairs may be currently used. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to solve a leak or other problem in a water/river crossing. (3) The typical travel distances required can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). In concept, these groups require pig-based systems; despooled umbilical systems could be considered for the first two groups

  6. Effect of surface roughness and adhesive system on repair potential of silorane-based resin composite

    Directory of Open Access Journals (Sweden)

    Enas H. Mobarak

    2012-07-01

    Full Text Available This study was performed to evaluate the influence of surface roughness and adhesive system on the repair strength of silorane-based resin composite. Twenty-four substrate discs from silorane-based FiltekP90 were made and stored for 24 h. Half of the discs were roughened against 320 grit SiC paper while the other half was polished against 4000 grit SiC paper. All discs were etched with phosphoric acid. Repair resin composite, FiltekP90 or FiltekZ250, was bonded to the treated surfaces using their corresponding adhesive; P90 System Adhesive (SA or Adper Scotchbond Multipurpose (SBMP ending up with four repair groups. The groups were as follows: G1: Smooth + SA + FiltekP90; G2: Roughened + SA + FiltekP90; G3: Smooth + SBMP + FiltekZ250; G4: Roughened + SBMP + FiltekZ250. Additional six unrepaired discs from each resin composite (G5 and G6 were prepared to test the cohesive strength. After 24 h, discs (n = 6/group were serially sectioned to obtain sticks (n = 30/group for microtensile bond strength (μTBS testing. Scanning electron microscopic (SEM evaluation of substrates that received different treatments as well as representative substrate-repair sticks from each group were performed. Modes of failure were also determined. Two-way ANOVA with Repeated-Measures revealed that surface treatment and repair material had no significant effect on repair bond strength of silorane-based composite material. Paired t-test showed that all repair strength values were significantly lower than the cohesive strength of FiltekP90. Adhesive failure was the predominant mode of failure which was confirmed by SEM. Surface treated FiltekP90 composite showed different textures under SEM whereas phosphoric acid did not produce clear changes. An interaction layer between SBMP adhesive and FiltekZ250 repairing composite was detected. Repair of the silorane composite was successful irrespective of the surface roughness and chemistry of the repair

  7. Collagen/silk fibroin composite scaffold incorporated with PLGA microsphere for cartilage repair.

    Science.gov (United States)

    Wang, Jianhua; Yang, Qiu; Cheng, Niangmei; Tao, Xiaojun; Zhang, Zhihua; Sun, Xiaomin; Zhang, Qiqing

    2016-04-01

    For cartilage repair, ideal scaffolds should mimic natural extracellular matrix (ECM) exhibiting excellent characteristics, such as biocompatibility, suitable porosity, and good cell affinity. This study aimed to prepare a collagen/silk fibroin composite scaffold incorporated with poly-lactic-co-glycolic acid (PLGA) microsphere that can be applied in repairing cartilage. To obtain optimum conditions for manufacturing a composite scaffold, a scaffold composed of different collagen-to-silk fibroin ratios was evaluated by determining porosity, water absorption, loss rate in hot water, and cell proliferation. Results suggested that the optimal ratio of collagen and silk fibroin composite scaffold was 7:3. The microstructure and morphological characteristics of the obtained scaffold were also examined through scanning electron microscopy and Fourier transform infrared spectroscopy. The results of in vitro fluorescence staining of bone marrow stromal cells revealed that collagen/silk fibroin composite scaffold enhanced cell proliferation without eliciting side effects. The prepared composite scaffold incorporated with PLGA microsphere was implanted in fully thick articular cartilage defects in rabbits. Collagen/silk fibroin composite scaffold with PLGA microspheres could enhance articular cartilage regeneration and integration between the repaired cartilage and the surrounding cartilage. Therefore, this composite will be a promising material for cartilage repair and regeneration.

  8. Modeling DNA Repair: Approaching In Vivo Techniques in the Hyperthermophile Sulfolobus Solfataricus

    Energy Technology Data Exchange (ETDEWEB)

    Blanton, J.; Fuss, J.; Yannone, S.M.; Tainer, J.A.; Cooper, P.K.

    2005-01-01

    Archaea are found in some of the most extreme environments on earth and represent a third domain of life distinct from Eukarya and Eubacteria. The hyperthermophilic archaeon Sulfolobus solfataricus, isolated from acidic hot springs (80oC, pH 3) in Yellowstone National Park, has emerged as a potential model system for studying human DNA repair processes. Archaea are more closely related to Eukarya than to Eubacteria, suggesting that archaeal DNA repair machinery may model the complex human system much more closely than that of other prokaryotes. DNA repair requires coordinated protein-protein interactions that are frequently transient. Protein complexes that are transient at extreme temperatures where archaea thrive may be more stable at room temperature, allowing for the characterization of otherwise short-lived complexes. However, characterization of these systems in archaea has been limited by the absence of a stable in vivo transformation and expression system. The work presented here is a pilot study in gene cloning and recombinant protein expression in S. solfataricus. Three genes associated with DNA repair were selected for expression: MRE11, PCNA1, and a putative CSB homologue. Though preparation of these recombinant genes followed standard methods, preparation of a suitable vector proved more challenging. The shuttle vector pSSV64, derived from the SSV1 virus and the E. coli vector pBSSK+, was most successfully isolated from the DH5α E. coli strain. Currently, alternative vectors are being designed for more efficient genetic manipulations in S. solfataricus.

  9. Ready Computer Services

    Institute of Scientific and Technical Information of China (English)

    Sun Yongjian

    2006-01-01

    @@ As a large scale modern commercial conference,Partenariat 2006 will offer convenient computer services which are necessary in improving efficiency. This is a very complicated job. The Preparation Commission has a special group to be in charge of the job. China's Foreign Trade interviewed Tan Ke, head of the group.

  10. The modified Koyanagi hypospadias repair for the one-stage repair of proximal hypospadias

    Directory of Open Access Journals (Sweden)

    Venkata R Jayanthi

    2008-01-01

    Full Text Available Perineal and penoscrotal hypospadias were often managed by two-stage urethroplasty with variable results and significant number of these may need third surgery. Though modified Koyanagi one-stage repair has a learning curve, it has all the advantages of two-stage repair. The aim was to review the results of modified Koyonagi repair from the literature and our own centre experience.

  11. 46 CFR 196.30-10 - Notice required before repair.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Notice required before repair. 196.30-10 Section 196.30... OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 196.30-10 Notice required before repair. (a) No repairs or alterations, except in an emergency, shall be made to any lifesaving or fire...

  12. 40 CFR 63.171 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Delay of repair. 63.171... Standards for Organic Hazardous Air Pollutants for Equipment Leaks § 63.171 Standards: Delay of repair. (a) Delay of repair of equipment for which leaks have been detected is allowed if repair within 15 days...

  13. 40 CFR 61.242-10 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standards: Delay of repair. 61.242-10... Leaks (Fugitive Emission Sources) § 61.242-10 Standards: Delay of repair. (a) Delay of repair of equipment for which leaks have been detected will be allowed if repair within 15 days is...

  14. 40 CFR 60.692-6 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Delay of repair. 60.692-6... From Petroleum Refinery Wastewater Systems § 60.692-6 Standards: Delay of repair. (a) Delay of repair of facilities that are subject to the provisions of this subpart will be allowed if the repair...

  15. 48 CFR 1371.118 - Changes-ship repair.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Changes-ship repair. 1371... SUPPLEMENTAL REGULATIONS ACQUISITIONS INVOLVING SHIP CONSTRUCTION AND SHIP REPAIR Provisions and Clauses 1371.118 Changes—ship repair. Insert clause 1352.271-87, Changes—Ship Repair, in all solicitations...

  16. 46 CFR 97.30-10 - Notice required before repair.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Notice required before repair. 97.30-10 Section 97.30-10... OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 97.30-10 Notice required before repair. (a) No repairs or alterations, except in an emergency, shall be made to any lifesaving or fire...

  17. 40 CFR 61.350 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standards: Delay of repair. 61.350... Waste Operations § 61.350 Standards: Delay of repair. (a) Delay of repair of facilities or units that are subject to the provisions of this subpart will be allowed if the repair is technically...

  18. 40 CFR 265.1059 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Delay of repair. 265.1059... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1059 Standards: Delay of repair. (a) Delay of repair of equipment for which leaks have been detected will be allowed if the repair...

  19. 40 CFR 264.1059 - Standards: Delay of repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Delay of repair. 264.1059... Air Emission Standards for Equipment Leaks § 264.1059 Standards: Delay of repair. (a) Delay of repair of equipment for which leaks have been detected will be allowed if the repair is...

  20. Recent trends in repair and refurbishing of steam turbine components

    Indian Academy of Sciences (India)

    A K Bhaduri; S K Albert; S K Ray; P Rodriguez

    2003-06-01

    The repair and refurbishing of steam generator components is discussed from the perspective of repair welding philosophy including applicable codes and regulations. Some case histories of repair welding of steam generator components are discussed with special emphasis on details of repair welding of cracked steam turbine blades and shrouds in some of the commercial nuclear power plants using procedures developed.

  1. 49 CFR 396.3 - Inspection, repair, and maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Inspection, repair, and maintenance. 396.3 Section..., REPAIR, AND MAINTENANCE § 396.3 Inspection, repair, and maintenance. (a) General. Every motor carrier and... and maintenance operations to be performed; (3) A record of inspection, repairs, and...

  2. A Minimum Cost Flow model for Level of Repair Analysis

    NARCIS (Netherlands)

    Basten, Robertus Johannes Ida; Schutten, Johannes M.J.; van der Heijden, Matthijs C.

    2008-01-01

    Given a product design and a repair network for capital goods, a level of repair analysis determines for each component in the product (1) whether it should be discarded or repaired upon failure and (2) at which location in the repair network to do this. In this paper, we show how the problem can be

  3. A minimum cost flow model for level of repair analysis

    NARCIS (Netherlands)

    Basten, Robertus Johannes Ida; van der Heijden, Matthijs C.; Schutten, Johannes M.J.

    2011-01-01

    Given a product design and a repair network for capital goods, a level of repair analysis determines for each component in the product (1) whether it should be discarded or repaired upon failure and (2) at which location in the repair network to do this. In this paper, we show how the problem can be

  4. 48 CFR 252.247-7025 - Reflagging or repair work.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Reflagging or repair work... of Provisions And Clauses 252.247-7025 Reflagging or repair work. As prescribed in 247.574(d), use the following clause: Reflagging or Repair Work (JUN 2005) (a) Definition. Reflagging or repair...

  5. 49 CFR 192.309 - Repair of steel pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Repair of steel pipe. 192.309 Section 192.309... Lines and Mains § 192.309 Repair of steel pipe. (a) Each imperfection or damage that impairs the serviceability of a length of steel pipe must be repaired or removed. If a repair is made by grinding, the...

  6. Autologous chondrocyte implantation: superior biologic properties of hyaline cartilage repairs.

    Science.gov (United States)

    Henderson, Ian; Lavigne, Patrick; Valenzuela, Herminio; Oakes, Barry

    2007-02-01

    Information regarding the quality of autologous chondrocyte implantation repair is needed to determine whether the current autologous chondrocyte implantation surgical technology and the subsequent biologic repair processes are capable of reliably forming durable hyaline or hyaline-like cartilage in vivo. We report and analyze the properties and qualities of autologous chondrocyte implantation repairs. We evaluated 66 autologous chondrocyte implantation repairs in 57 patients, 55 of whom had histology, indentometry, and International Cartilage Repair Society repair scoring at reoperation for mechanical symptoms or pain. International Knee Documentation Committee scores were used to address clinical outcome. Maximum stiffness, normalized stiffness, and International Cartilage Repair Society repair scoring were higher for hyaline articular cartilage repairs compared with fibrocartilage, with no difference in clinical outcome. Reoperations revealed 32 macroscopically abnormal repairs (Group B) and 23 knees with normal-looking repairs in which symptoms leading to arthroscopy were accounted for by other joint disorders (Group A). In Group A, 65% of repairs were either hyaline or hyaline-like cartilage compared with 28% in Group B. Autologous chondrocyte repairs composed of fibrocartilage showed more morphologic abnormalities and became symptomatic earlier than hyaline or hyaline-like cartilage repairs. The hyaline articular cartilage repairs had biomechanical properties comparable to surrounding cartilage and superior to those associated with fibrocartilage repairs.

  7. Targeting base excision repair as a sensitization strategy in radiotherapy.

    NARCIS (Netherlands)

    Vens, C.; Begg, A.C.

    2010-01-01

    Cellular DNA repair determines survival after ionizing radiation. Human tumors commonly exhibit aberrant DNA repair since they drive mutagenesis and chromosomal instability. Recent reports have shown alterations in the base excision repair (BER) and single strand break repair (SSBR) pathways in huma

  8. Optimal scheduling of logistical support for an emergency roadway repair work schedule

    Science.gov (United States)

    Yan, S.; Lin, C. K.; Chen, S. Y.

    2012-09-01

    The completion of every disaster rescue task performed by repair work teams relies on the in-time supply of materials to the rescue workers. Up to now, logistical support planning for emergency repair work in Taiwan has been done manually, which is neither effective nor efficient. To remedy the problem, this study presents a logistical support scheduling model for the given emergency repair work schedule. The objective is to minimize the short-term operating cost subject to time constraints and other related operating constraints. This model is formulated as an integer multiple-commodity network flow problem which is characterized as NP-hard. A heuristic algorithm, based on the problem decomposition and variable fixing techniques, is also proposed to efficiently solve this problem. Computational tests are performed using data from Taiwan's 1999 Chi-Chi earthquake. The results show that the model and the solution algorithm would be useful for the logistical support scheduling.

  9. Laparoscopic repair of a bilateral internal inguinal hernia with supravesical hernia – a case report

    Science.gov (United States)

    Kawaguchi, Tsutomu; Itoh, Tadao; Yoshii, Kazuhiro; Otsuji, Eigo

    2015-01-01

    Introduction Supravesical hernia is an exceptional subtype of internal inguinal hernia, and it is located between the median umbilical ligament and the medial umbilical ligament. The hernia is classified as two types: internal supravesical hernia and external supravesical hernia. Presentation of case Herein we report a rare case of external supravesical hernia successfully treated by laparoscopic procedure. The patient who complained right inguinal protrusion and mild frequent urination was diagnosed as right inguinal hernia and potential of left inguinal hernia using computed tomography. He underwent laparoscopic bilateral hernia repair, and intraoperative findings revealed right external supravesical hernia and left internal inguinal hernia. Discussion Laparoscopic hernia repair may make it possible to avoid overlooking of internal hernia such as supravesical hernia. Moreover it was possible to cover the hernia orifice and dissected layer of the dorsal site of urine bladder using bilateral approach in the current case. Conclusion In conclusions, laparoscopic hernia repair might be a surgical option for supravesical hernia. PMID:26263448

  10. Transcription-coupled DNA repair in prokaryotes.

    Science.gov (United States)

    Ganesan, Ann; Spivak, Graciela; Hanawalt, Philip C

    2012-01-01

    Transcription-coupled repair (TCR) is a subpathway of nucleotide excision repair (NER) that acts specifically on lesions in the transcribed strand of expressed genes. First reported in mammalian cells, TCR was then documented in Escherichia coli. In this organism, an RNA polymerase arrested at a lesion is displaced by the transcription repair coupling factor, Mfd. This protein recruits the NER lesion-recognition factor UvrA, and then dissociates from the DNA. UvrA binds UvrB, and the assembled UvrAB* complex initiates repair. In mutants lacking active Mfd, TCR is absent. A gene transcribed by the bacteriophage T7 RNA polymerase in E. coli also requires Mfd for TCR. The CSB protein (missing or defective in cells of patients with Cockayne syndrome, complementation group B) is essential for TCR in humans. CSB and its homologs in higher eukaryotes are likely functional equivalents of Mfd. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Final Design Analysis : Lake Ladora Dam Repair

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This report is intended to present Rocky Mountain Arsenal with details concerning the remedial repair for Ladora Dam to meet the geotechnical concerns and hydrologic...

  12. PRP and Metaplasia in repaired tendon

    Directory of Open Access Journals (Sweden)

    Kamal Seyed-Forootan

    2014-01-01

    Conclusion: It seems that using PRP has no effect on strengthening the tendons repair and may have some adverse effects. It usage needs further studies to evaluate their probable adverse side effects.

  13. DNA repair genes in the Megavirales pangenome.

    Science.gov (United States)

    Blanc-Mathieu, Romain; Ogata, Hiroyuki

    2016-06-01

    The order 'Megavirales' represents a group of eukaryotic viruses with a large genome encoding a few hundred up to two thousand five hundred genes. Several members of Megavirales possess genes involved in major DNA repair pathways. Some of these genes were likely inherited from an ancient virus world and some others were derived from the genomes of their hosts. Here we examine molecular phylogenies of key DNA repair enzymes in light of recent hypotheses on the origin of Megavirales, and propose that the last common ancestors of the individual families of the order Megavirales already possessed DNA repair functions to achieve and maintain a moderately large genome and that this repair capacity gradually increased, in a family-dependent manner, during their recent evolution.

  14. Pain characteristics after laparoscopic inguinal hernia repair

    DEFF Research Database (Denmark)

    Tolver, Mette A; Strandfelt, Pernille; Rosenberg, Jacob;

    2011-01-01

    Previous studies have shown different pain characteristics in different types of laparoscopic operations, but pain pattern has not been studied in detail after laparoscopic inguinal hernia repair. To optimise preoperative patient information and postoperative analgesic treatment the present study...

  15. NIU's Kinder, Gentler, Housing Repair System.

    Science.gov (United States)

    Tillis, Linda; Montgomery, Rogene

    1999-01-01

    Explains the effective use of a centralized housing-repair request system at Northern Illinois University that has improved customer service and increased fiscal accountability. Describes the system and assesses of its effectiveness. (GR)

  16. Erosion Resistant Compressor Blade Repair Technologies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR program will demonstrate the use of wear resistant high strength nanocomposites in the turbine engine repair and refurbishment process. The...

  17. Lichtenstein versus Onstep for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2013-01-01

    Inguinal hernia is a common condition that affects millions of people world-wide every year. In Denmark (population of 5.5 million), more than 10,000 repairs of inguinal hernias are performed annually. The optimal surgical procedure for mesh placement and fixation is still being debated because...... of long-term complications such as persisting pain and impairment of sexual function. The Onstep approach is a newer type of groin hernia repair with promising preliminary results in terms of very few cases of chronic pain and recurrences. This protocol describes a randomised clinical trial the objective...... of which is to evaluate chronic pain and sexual dysfunction after inguinal hernia repair using the Lichtenstein repair compared with the Onstep approach....

  18. Lichtenstein versus Onstep for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2013-01-01

    Inguinal hernia is a common condition that affects millions of people world-wide every year. In Denmark (population of 5.5 million), more than 10,000 repairs of inguinal hernias are performed annually. The optimal surgical procedure for mesh placement and fixation is still being debated because...... of which is to evaluate chronic pain and sexual dysfunction after inguinal hernia repair using the Lichtenstein repair compared with the Onstep approach....... of long-term complications such as persisting pain and impairment of sexual function. The Onstep approach is a newer type of groin hernia repair with promising preliminary results in terms of very few cases of chronic pain and recurrences. This protocol describes a randomised clinical trial the objective...

  19. Laparoscopic transabdominal extraperitoneal repair of lumbar hernia

    Directory of Open Access Journals (Sweden)

    Sharma A

    2005-01-01

    Full Text Available Lumbar hernias need to be repaired due to the risk of incarceration and strangulation. A laparoscopic intraperitoneal approach in the modified flank position causes the intraperitoneal viscera to be displaced medially away from the hernia. The creation of a wide peritoneal flap around the hernial defect helps in mobilization of the colon, increased length of margin is available for coverage of mesh and more importantly for secure fixation of the mesh under vision to the underlying fascia. Laparoscopic lumbar hernia repair by this technique is a tensionless repair that diffuses total intra-abdominal pressure on each square inch of implanted mesh. The technique follows current principles of hernia repair and appears to confer all benefits of a minimal access approach.

  20. Light-Curing Adhesive Repair Tapes

    Science.gov (United States)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.