WorldWideScience

Sample records for preoperative ct scanning

  1. The use of CT scan in the pre-operative staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Pada, C.C.

    1992-01-01

    Surgery remains the treatment of choice in patients with localized bronchogenic carcinoma. Pre-operative identification of inoperability spares the patient from unnecessary surgery. This prospective study was carried out to determine the correctness of judgement regarding a patient's operability or inoperability based on the pre-operative staging of CT scan; to find out the sensitivity, specificity and overall accuracy of the CT scan in estimating tumor description, nodal status and metastatic spread to the chest. Staging was done by 3 senior radiologists aware of the diagnosis. Both the surgical and histopathologic findings and staging were gathered and used as measurement of truth in arriving at the CT scan's accuracy. Overall accuracy rate of CT scan in determining operability or inoperability is 80%; tumor description accuracy of assessment is 87% and nodal status estimation has an accuracy of 60%. Sensitivity of CT scan is assessment of metastatic spread to the chest is 93%. There is no statistically significant difference in the judgement of operability or interpretability by CT scan compared to surgical and histopathologic results. The CT scan is recommended as a valuable tool in the pre-operative staging of patients with bronchogenic carcinoma who are candidates for surgery. (auth.). 21 refs.; 8 tabs

  2. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  3. Preoperative CT evaluation of adenocarcinoma of the gastroesophageal junction

    International Nuclear Information System (INIS)

    Bennett, J.D.; Lefcoe, M.S.; Finley, R.; Yoshi, C.; Inculet, R.

    1988-01-01

    A retrospective review was undertaken of 53 preoperative computed tomographic (CT) scans obtained between March 1983 and April 1988 from patients undergoing surgery for adenocarcinoma of the gastroesophageal junction, and results were correlated with the surgical-pathologic findings. CT was unreliable in predicting aortic, pericardial, or pancreatic invasion (sensitivity, 0/8; specificity, 41/45). Of 45 pathologically positive nodal groups, the largest node measured on CT scans was 10 mm or less in 36 cases. The accuracy of preoperative CT in staging adenocarcinoma of the gastroesophageal junction is limited by its low sensitivity in detecting local invasion. Nodal size as measured with CT is not a reliable indicator of metastatic disease

  4. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  5. Preoperative CT evaluation on nasal cavity for transsphenoidal approach

    International Nuclear Information System (INIS)

    Saeki, Naokatsu; Yamaura, Akira; Hoshi, Seiichiro; Sunada, Souichi; Sunami, Kenro

    1997-01-01

    Preoperative bone CT scans sliced parallel to the surgical plane were evaluated in 32 cases of transsphenoidal surgery. This method predicted patients with narrow nasal cavity, and helped to determine the rhinological maneuvers for providing a wider operative field. In addition, it helps to plan the need and extent of sella floor removal in re-operated cases. There was relatively little difference in the width and length of the nasal cavity between acromegalic and non-acromegalic patients. Hence, bone CT scans are useful in the preoperative evaluation of patients undergoing transsphenoidal surgery. (author)

  6. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  7. Adenocarcinoma of the pancreatic head: preoperative helical CT. Criteria of resectability

    International Nuclear Information System (INIS)

    Kozima, Shigeru; Szelagowski, Carlos; Tisserand, Guy L.; Ocampo, Carlos; Zandalazini, Hugo; Silva, Walter; Oria, Alejandro; Vidovic, Gustavo; Varas, Pablo

    2001-01-01

    Objective: The purpose of this study is to determine the accuracy of biphasic helical CT scanning in predicting resectability of adenocarcinoma of the head of the pancreas by staying tumor involvement of the portal and superior mesenteric veins. Material and methods: 46 patients with proven adenocarcinoma of the head of the pancreas who underwent curative or palliative surgery were studied with preoperative biphasic helical CT scanning. Tumor involvement of the portal and mesenteric veins was graduated on a 1-3 scale based on circumferential contiguity of the tumor vessel. Grade 1: without contact; grade 2: tumor involvement of less than 50% of the vessel; grade 3: tumor involvement of more than 50%. Results: The total number of vessels evaluated was 92. In our series the preoperative biphasic helical CT was accurate in 77% for resectability and unresectability. Conclusion: Our experience of staging in 3 grades with biphasic helical CT, vessel involvement the portal and superior mesenteric veins of adenocarcinoma of the head of the pancreas is highly specific for unresectable tumor in patients who were graded 2 and 3. (author)

  8. Role of CT scan in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Salem, O.A.; Khasawneh, M.

    2007-01-01

    To evaluate the diagnostic accuracy of the spiral-CT in patients with clinically suspected acute appendicitis. A total of 124 patients referred for CT scan with suspected appendicitis between January 2005 and October 2006 were assessed for the appendiceal size and the presence of signs of appendicitis. The findings were correlated with surgical histopathology. CT scan had a sensitivity of 95 percent and a specifity of 93 percent and an overall accuracy of 92 percent. The use of spiral CT in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to significant improvement in the preoperative diagnosis. (author)

  9. Detailed Review of CT Scans Aids Assessment of the Airway in ...

    African Journals Online (AJOL)

    Two cases are presented that illustrate the importance of information gained from CT scans of the head and neck taken in patients presenting for maxillo-facial surgery. The first case involved a 25 year old with a massive tumour filling his mouth. Pre-operative assessment was done without reviewing the CT scans of his ...

  10. Preoperative and Postoperative CT Scan Assessment of Pterygomaxillary Junction in Patients Undergoing Le Fort I Osteotomy: Comparison of Pterygomaxillary Dysjunction Technique and Trimble Technique-A Pilot Study.

    Science.gov (United States)

    Dadwal, Himani; Shanmugasundaram, S; Krishnakumar Raja, V B

    2015-09-01

    To determine the rate of complications and occurrence of pterygoid plate fractures comparing two techniques of Le Fort I osteotomy i.e., Classic Pterygomaxillary Dysjunction technique and Trimble technique and to know whether the dimensions of pterygomaxillary junction [determined preoperatively by computed tomography (CT) scan] have any influence on pterygomaxillary separation achieved during surgery. The study group consisted of eight South Indian patients with maxillary excess. A total of 16 sides were examined by CT. Preoperative CT was analyzed for all the patients. The thickness and width of the pterygomaxillary junction and the distance of the greater palatine canal from the pterygomaxillary junction was noted. Pterygomaxillary dysjunction was achieved by two techniques, the classic pterygomaxillary dysjunction technique (Group I) and Trimble technique (Group II). Patients were selected randomly and equally for both the techniques. Dysjunction was analyzed by postoperative CT. The average thickness of the pterygomaxillary junction on 16 sides was 4.5 ± 1.2 mm. Untoward pterygoid plate fractures occurred in Group I in 3 sides out of 8. In Trimble technique (Group II), no pterygoid plate fractures were noted. The average width of the pterygomaxillary junction was 7.8 ± 1.5 mm, distance of the greater palatine canal from pterygomaxillary junction was 7.4 ± 1.6 mm and the length of fusion of pterygomaxillary junction was 8.0 ± 1.9 mm. The Le Fort I osteotomy has become a standard procedure for correcting various dentofacial deformities. In an attempt to make Le Fort I osteotomy safer and avoid the problems associated with sectioning with an osteotome between the maxillary tuberosity and the pterygoid plates, Trimble suggested sectioning across the posterior aspect of the maxillary tuberosity itself. In our study, comparison between the classic pterygomaxillary dysjunction technique and the Trimble technique was made by using postoperative CT scan

  11. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  12. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  13. C.T. scanning in the pre-operative assessment of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Goldstraw, P.

    1986-01-01

    The concept of T.N.M. staging is now widely adopted, providing an international shorthand to describe tumour extent. Throughout this article the system referred to is that of the American Joint Committee on Cancer Staging and End Results Reporting. It is generally now accepted that Stage I and II patients with N.S.C.L.C. benefit from pulmonary resection, whilst those with Stage III tumours by virtue of T3 status, N2 disease or M stage other than zero, do not. There are exceptions to this rule and they are discussed in the relevant section. The authors therefore consider the role of C.T. scanning in pre-operative staging under the following headings. Tumour characteristics: 1) indicators of malignancy, 2) extra-pulmonary extension; Nodal metastases: 1) hilar, 2) mediastinal; Metastases to distant sites

  14. CT-scanning in otolaryngology, 2

    International Nuclear Information System (INIS)

    Kusakari, Jun; Endo, Satomi; Hara, Akira

    1982-01-01

    Combined computerized tomography-sialography was performed in 28 patients with parotid tumors. Sialography was performed in the usual fashion. After confirming the presence of the contrast material within the parotid gland by X-ray, 4 to 5 scannings were done at the width of 10 mm below Repid's base line. With this procedure, the parotid gland was clearly demonstrated and the location of the tumor was shown as a shadow defect. Although the nature of the tumor, especially whether it was malignant or benign was difficult to predict, the CT-findings regarding the size and location of the tumor were completely coincident with the operative findings in all the cases. Accurate appraisal of the relation between the tumor and the facial nerve was possible in all but two cases. The preoperative information obtained from CT-scanning is extremely useful in the case of parotid tumor surgery. (author)

  15. The Usefulness of 99mTc-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism

    International Nuclear Information System (INIS)

    Baik, S. H.; Kim, S. M.; Choi, K. M.; Choi, Y. S.; Kim, S. J.; Yu, J. M.; Choi, D. S.; Choe, J. C.

    1995-01-01

    An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and 201 T1/ 99m Tc-subtraction scan. Among them 201T1/99mTc subtraction scan in known as the most accurate tool for preoperative localization. Recently 201 T1/ 99m Tc-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with 201 T1/ 99m Tcsubtraction imaging and 99m Tc-Sestamibi. The sensitivities of the 99m Tc-Sestamibi, 201T1/99mTc subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of 99m Tc-Sestamibi and 201 T1/ 99T c-subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the 99m Tc-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  16. Comparison between FDG Uptake and Pathologic or Immunohistochemical Parametersin Pre-operative PET/CT Scan of Patient with Primary Colorectal Cancer

    International Nuclear Information System (INIS)

    Na, Sae Jung; Chung, Yong An; Maeng, Lee So; Kim, Ki Jun; Sohn, Kyung Myung; Kim, Sung Hoon; Sohn, Hyung Sun; Chung, Soo Kyo

    2009-01-01

    To evaluate the relationship between F-18 FDG uptake of tumor in PET/CT scan and pathological or immunohistochemial parameters of colorectal cancer. 147 colorectal cancer patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The pathologic results such as site, size, depth of invasion (T stage), growth pattern, differentiation of primary tumor, lymph node metastasis and Dukes-Astler and Coller stage and immunohistochemical markers such as expression of EGFR, MLH1, MSH2 and Ki-67 index were reviewed. 146 out of 147 PET/CT scans with colorectal cancer showed perceptible focal FDG uptake. SUVmax showed mild positive linear correlation with size of primary tumor (r=0.277, p=0.001) and Ki-67 index (r=0.226, p=0.019). No significant difference in F-18 FDG uptake was found according to site, depth of invasion (T stage), growth pattern, differentiation of primary tumor, presence of lymph node metastasis, Dukes-Astler and Coller stage and expression of EGFR. The degree of F-18 FDG uptake in colorectal cancer was associated with the size and the degree of Ki-67 index of primary tumor. It could be thought that FDG uptake of primary tumor has a correlation with macroscopic and microscopic tumor growth

  17. Comparison between FDG Uptake and Clinicopathologic and Immunohistochemical Parameters in Pre-operative PET/CT Scan of Primary Gastric Carcinoma

    International Nuclear Information System (INIS)

    Han, Eun Ji; Choi, Woo Hee; Chung, Yong An; Kim, Ki Jun; Maeng, Lee So; Sohn, Kyung Myung; Jung, Hyun Suk; Sohn, Hyung Sun; Chung, Soo Kyo

    2009-01-01

    The purpose of this study was to find out what clinicopathologic or immunohistochemical parameter that may affect FDG uptake of primary tumor in PET/CT scan of the gastric carcinoma patient. Eighty-nine patients with stomach cancer who underwent pre-operative FDG PET/CT scans were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The clinicopathologic results such as depth of invasion (T stage), tumor size, lymph node metastasis, tumor differentiation and Lauren's classification and immunohistochemical markers such as Ki-67 index, expression of p53, EGFR, Cathepsin D, c-erb-B2 and COX-2 were reviewed. Nineteen out of 89 gastric carcinomas showed imperceptible FDG uptake on PET/CT images. In cases with perceptible FDG uptake in primary tumor, SUVmax was significantly higher in T2, T3 and T4 tumors than T1 tumors (5.8±3.1 vs. 3.7±2.1, p=0.002). SUVmax of large tumors (above or equal to 3 cm) was also significantly higher than SUVmax of small ones (less than 3 cm) (5.7±3.2 vs. 3.7±2.0, p=0.002). The intestinal types of gastric carcinomas according to Lauren showed higher FDG uptake compared to the non-intestinal types (5.4±2.8 vs. 3.7±1.3, p=0.003). SUVmax between p53 positive group and negative group was significantly different (6.0±2.8 vs. 4.4±3.0, p=0.035). No significant difference was found in presence of LN metastasis, tumor differentiation, Ki-67 index, and expression of EGFR, Cathepsin D, c-erb-B2 and COX-2. T stage of gastric carcinoma influenced the detectability of gastric cancer on FDG PET/CT scan. When gastric carcinoma was perceptible on PET/CT scan, T stage, size of primary tumor, Lauren's classification and p53 expression were related to degree of FDG uptake in primary tumor

  18. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  19. Topographic diagnosis of parathyroid tumor by CT scan

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Harioka, Toshio; Morita, Rikuji

    1981-01-01

    In order to detect the hyperfunctioning parathyroid gland(s), CT scan over the neck was performed in patients with parathyroid disorders, including 10 primary hyperparathyroidism (6 bone type, 3 stone type and 1 chemical type), 8 chronic renal failure on hemodialysis with renal osteodystrophy and 2 multiple endocrine adenomatosis (MEA) type I. We used a whole-body scanner (CT/T, GE). The slice thickness was 5 mm. All patients were scanned from the sternal notch upward to the larynx, and were enhanced by the administration of 30% DIP Conray for 15 min. The results of the topographic diagnosis were compared with the surgical findings. Precise preoperative localization was accomplished in 9/10 adenomas in primary hyperparathyroidism, 27/32 hyperplasias in secondary hyperparathyroidism, and 2/4 hyperplasias in MEA type I. The smallest lesion weighed 0.2 g. It was shown that CT scan over the neck was a noninvasive and simple method to define the localization of hyperfunctionig parathyroid gland(s). (author)

  20. Comparison of preoperative computerized tomography scan imaging of temporal bone with the intra-operative findings in patients undergoing mastiodectomy

    International Nuclear Information System (INIS)

    Gerami, H.; Naghavi, E.; Wahabi-Moghadam, M.; Forghanparast, K.; Akbar, Manzar H.

    2009-01-01

    Objective was to compare the consistency rates of pre- and intra-operative radiological findings in patients with chronic suppurative otitis media (CSOM). In a cross-sectional study, 80 patients with CSOM underwent pre-operative CT scanning and we compared the results with intra-operative clinical findings during mastiodectomy from 2000-2004 in the Otology Department, Amiralmomenin Hospital of Guilan Medical University, Rasht, Iran. Sensitivity, specificity, positive and negative predictive value of CT scan in tympanic and mastoid cholesteatoma, ossicular chain erosion, tegmentympani erosion, dehiscence of facial canal, lateral semicircular canal (LSCC) fistula were assessed. Then, correlation between radiological findings and intra-operative findings were calculated. The mean age of patients was 27.9+-16.3 years. Mostly were males (n=57 [71.3%]). Correlation of preoperative radiological images with intra-operative clinical findings were moderate to good on tympanic cholesteatoma, mastoid cholesteatoma and ossicular chain erosion, but weak and insignificant in cases of tegmen erosion, facial canal dehiscene and LSCC fistulae. Preoperative CT scan may be helpful in decision-making for surgery in cases of cholesteatoma and ossicular erosion. Despite of limitations radiological scanning is a useful adjunct to management of CSOM. (author)

  1. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  2. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  3. Clinical Utility of Preoperative Computed Tomography in Patients With Endometrial Cancer.

    Science.gov (United States)

    Bogani, Giorgio; Gostout, Bobbie S; Dowdy, Sean C; Multinu, Francesco; Casarin, Jvan; Cliby, William A; Frigerio, Luigi; Kim, Bohyun; Weaver, Amy L; Glaser, Gretchen E; Mariani, Andrea

    2017-10-01

    The aim of this study was to determine the clinical utility of routine preoperative pelvic and abdominal computed tomography (CT) examinations in patients with endometrial cancer (EC). We retrospectively reviewed records from patients with EC who underwent a preoperative endometrial biopsy and had surgery at our institution from January 1999 through December 2008. In the subset with an abdominal CT scan obtained within 3 months before surgery, we evaluated the clinical utility of the CT scan. Overall, 224 patients (18%) had a preoperative endometrial biopsy and an available CT scan. Gross intra-abdominal disease was observed in 10% and 20% of patients with preoperative diagnosis of endometrioid G3 and type II EC, respectively, whereas less than 5% of patients had a preoperative diagnosis of hyperplasia or low-grade EC. When examining retroperitoneal findings, we observed that a negative CT scan of the pelvis did not exclude the presence of pelvic node metastasis. Alternately, a negative CT scan in the para-aortic area generally reduced the probability of finding para-aortic dissemination but with an overall low sensitivity (42%). However, the sensitivity for para-aortic dissemination was as high as 67% in patients with G3 endometrioid cancer. In the case of negative para-aortic nodes in the CT scan, the risk of para-aortic node metastases decreased from 18.8% to 7.5% in patients with endometrioid G3 EC. Up to 15% of patients with endometrioid G3 cancer had clinically relevant incidental findings that necessitated medical or surgical intervention. In patients with endometrioid G3 and type II EC diagnosed by the preoperative biopsy, CT scans may help guide the operative plan by facilitating preoperative identification of gross intra-abdominal disease and enlarged positive para-aortic nodes that are not detectable during physical examinations. In addition, CT may reveal other clinically relevant incidental findings.

  4. Preoperative staging of lung cancer with PET/CT: cost-effectiveness evaluation alongside a randomized controlled trial

    DEFF Research Database (Denmark)

    Søgaard, Rikke; Fischer, Barbara Malene B; Mortensen, Jann

    2011-01-01

    PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost-effective......PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost......-effectiveness. The objective of this study was to assess the cost-effectiveness of PET/CT as an adjunct to conventional workup for preoperative staging of NSCLC. METHODS: The study was conducted alongside an RCT in which 189 patients were allocated to conventional staging (n = 91) or conventional staging + PET/CT (n = 98......) and followed for 1 year after which the numbers of futile thoracotomies in each group were monitored. A full health care sector perspective was adapted for costing resource use. The outcome parameter was defined as the number needed to treat (NNT)-here number of PET/CT scans needed-to avoid one futile...

  5. Selection of colon cancer patients for neoadjuvant chemotherapy by preoperative CT scan

    DEFF Research Database (Denmark)

    Nørgaard, Anne; Dam, Claus; Jakobsen, Anders

    2014-01-01

    invasion (ETI), nodal stage (N-stage), extramural venous invasion (EVI) and the distance from tumor to nearest retroperitoneal fascia (DRF) were retrospectively assessed on the CT scan and compared blindly with the results of the pathological examination, including evaluation of the criteria for adjuvant...

  6. Preoperative PET/CT in early-stage breast cancer

    DEFF Research Database (Denmark)

    Bernsdorf, M; Berthelsen, A K; Timmermans-Wielenga, Vera

    2012-01-01

    The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer.......The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer....

  7. Preoperative CT analysis of the mandible and maxilla for permanent dental prosthetic implantation

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Rhodes, M.L.; Schwarz, M.; Chafetz, N.I.

    1987-01-01

    The Branemark technique for permanently implanting dental prostheses is becoming universally accepted. The surgeon requires detailed knowledge of the cross-sectional anatomy of the alveolar ridges and inferior alveolar nerve for safe placement of the titanium fixtures. Axial CT scans of the mandible and maxilla, with oblique and panoramic CT reformations, were obtained in more than 100 patients. This report describes the anatomic variations in the maxilla and mandible as they relate to dental implantation surgery. The authors demonstrate the utility of this technique in preoperative surgical planning and postoperative evaluation

  8. Preoperative CT versus diffusion weighted magnetic resonance imaging of the liver in patients with rectal cancer; a prospective randomized trial

    Directory of Open Access Journals (Sweden)

    Michael P. Achiam

    2016-01-01

    Full Text Available Introduction. Colorectal cancer is one of the most frequent cancers in the world and liver metastases are seen in up to 19% of patients with colorectal cancers. Detection of liver metastases is not only vital for sufficient treatment and survival, but also for a better estimation of prognosis. The aim of this study was to evaluate the feasibility of diffusion weighted MRI of the liver as part of a combined MR evaluation of patients with rectal cancers and compare it with the standard preoperative evaluation of the liver with CT.Methods. Consecutive patients diagnosed with rectal cancers were asked to participate in the study. Preoperative CT and diffusion weighted MR (DWMR were compared to contrast enhanced laparoscopic ultrasound (CELUS.Results. A total of 35 patients were included, 15 patients in Group-1 having the standard CT evaluation of the liver and 20 patients in Group-2 having the standard CT evaluation of the liver and DWMR of the liver. Compared with CELUS, the per-patient sensitivity/specificity was 50/100% for CT, and for DWMR: 100/94% and 100/100% for Reader 1 and 2, respectively. The per-lesion sensitivity of CT and DWMR were 17% and 89%, respectively compared with CELUS. Furthermore, one patient had non-resectable metastases after DWMR despite being diagnosed with resectable metastases after CT. Another patient was diagnosed with multiple liver metastases during CELUS, despite a negative CT-scan.Discussion. DWMR is feasible for preoperative evaluation of liver metastases. The current standard preoperative evaluation with CT-scan results in disadvantages like missed metastases and futile operations. We recommend that patients with rectal cancer, who are scheduled for MR of the rectum, should have a DWMR of the liver performed at the same time.

  9. Combined diagnosis of lateral cervical masses by RI-scintigraphy, ultrasound and CT-scanning

    International Nuclear Information System (INIS)

    Yang, Kuang-Tsuong; Yamashita, Toshio; Sasa, Hidehiko

    1984-01-01

    Careful palpation, plain X-rays and angiography are useful in the diagnosis of lateral cervical masses, but accurate preoperative evaluation sometimes needs further examinations. Recently several new auxiliary procedures have become available such as RI-scintigraphy, Ultrasound, and CT-scanning but even these may not be sufficient when used singly. When all these procedures were combined preoperatively in the case of lateral cervical masses and the results were compared with the findings at time of surgery and the pathology of the extirpated masses, acurate preoperative diagnose were possible. (author)

  10. Value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression

    Directory of Open Access Journals (Sweden)

    Ai-Jun Wu

    2016-12-01

    Full Text Available Objective: To study the value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression. Methods: A total of 135 patients with gastric cancer who received surgical resection in our hospital between May 2012 and October 2015 were selected as the research subjects, preoperative enhanced multi-slice spiral CT scan was conducted to judge TNM staging, and serum was collected to determine the content of tumor markers; tumor tissue was collected after operation to determine the content of cytokines and pro-proliferation molecules. Results: CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM II, III and IV stage gastric cancer were significantly higher than those of patients with TNM I stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM III and IV stage gastric cancer were significantly higher than those of patients with TNM II stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM IV stage gastric cancer were significantly higher than those of patients with TNM III stage. Conclusions: TNM staging of gastric cancer decided by preoperative enhanced multi-slice spiral CT scan has good consistency with the content of tumor markers in serum and proliferation molecules in tumor lesion.

  11. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  12. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    Science.gov (United States)

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  13. Lower rectal cancer. Preoperative staging with CT air enema technique

    International Nuclear Information System (INIS)

    Kanazawa, Amane; Fujii, Shouichi; Iwata, Seiichirou

    2009-01-01

    Preoperative assessment of rectal cancer wall invasion is an important indication of the need for lateral side wall dissection. The purpose of this study was to determine the accuracy rates and clinical usefulness of air-enema CT in preoperative staging of lower rectal cancer. A total of 88 patients diagnosed with lower rectal cancer were examined with an air-enema CT preoperatively and had surgical resection performed. One group was T1-T2 while the other was T3-T4. Forty-two patients were T1-T2, and 46 patients were T3-T4. In univariate and multivariate analysis, irregularities of the rectal wall and spiculated appearance of the rectal wall were significant predictive factors in T3-T4. In patients with air-enema CT findings of rectal wall irregularities and speculated appearance, the accuracy rate for detecting T3-T4 was 85.2-86.45 percent. These results show that air-enema CT is useful for determining the preoperative staging of lower rectal cancer and indication of the need for lateral side wall dissection. (author)

  14. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  15. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  16. How to distinguish between bleeding and coagulated extradural hematomas on the plain CT scanning

    International Nuclear Information System (INIS)

    Petersen, O.F.; Espersen, J.O.

    1984-01-01

    Four types of extradural hematoma could be separated at examination of the plain CT scan in 54 extradural hematomas. Two major groups appear: the still bleeding hematoma showing either generally low attenuation values of ''holes'', and a coagulated homogenous type with generally high attenuation values. The attenuation values of the bleeding-liquid part of hematoma - were correlated to hemoglobin concentration in blood, to which clots were not related. Seven extradural hematomas grew and coagulated on repeated preoperative CT scans. In two cases intravenous contrast was given to the bleeding type of hematoma, and the contrast media appeared in ''holes'', but not in areas of high attenuation value. It is easy to distinguish between the different types of hematoma on the plain CT scan, and the separation by eye between the still bleeding and the coagulated extradural hematoma seems reliable. (orig.)

  17. Preoperative localization of parathyroid tumor by computerized tomography

    International Nuclear Information System (INIS)

    Kan, Seiji; Hiraishi, Koji; Nakamura, Shoichiro; Yamamoto, Schuzo; Odachi, Motoaki; Yamashita, Toshiyuki.

    1984-01-01

    Five patients of primary hyperparathyroidism with urolithiasis underwent CT-scanning for the preoperative localization of parathyroid tumor. The tumor was identified in all patients but one, who had a multiple adenomatous goiter. In this case, postoperative observation of the CT-scan revealed the parathyroid tumor. It appears that if the size of the parathyroid tumor is about 1cm in diameter, there is a high possibility of preoperative localization by computerized tomography. (author)

  18. Preoperative CT assessment of esophageal carcinoma : comparison between the patients with and without recurrence of esophageal carcinoma after surgical resection

    International Nuclear Information System (INIS)

    Lee, Young Hen; Oh, Yu Whan; Cho, Kyu Ran; Park, Bum Jin; Lee, Nam Jun; Chung, Kyoo Byung

    2001-01-01

    To determine whether preoperative CT is helpful in predicting the development of recurrent tumor following surgical resection in patients with esophageal cancer. Thirty patients with esophageal cancer in whom preoperative CT of the chest had been performed were included in the study. All had undergone esophagectomy, esophagogastrostomy and lymph node dissection at our institution between 1995 and 1997. They were divided into two groups according to the development of tumor recurrence during the follow-up period of three years. Sixteen patients (group I) suffered tumor recurrence, while the other 14 (group II) remained tumor-free after surgery. In each group, a review of the preoperative CT scans indicated the length, thickness, location and margin of the tumor, and the presence or absence of lymphadenopathy in the mediastinum and/or upper abdomen. Differences in preoperative CT findings between the two groups were assessed by statistical testing. Lymphadenopathy of the mediastinum and/or upper abdomen was seen in 11 (69%) of 16 patients in group I and three (21%) of 14 in group II (p .05). In group I, five esophageal tumors were located in the middle esophagus and eleven in the lower esophagus. In group II, such tumor was located one in the upper esophagus, six in the middle esophagus, and seven in the lower esophagus (p>.05). Patients with preoperative CT findings of lymphadenopathy and/or and indistinct primary tumor margin are more likely to develop tumor recurrence following surgical resection than those without these findings

  19. Radiation protection for the eyes of the children experiencing an operation of artificial cochlear implant against CT scan

    International Nuclear Information System (INIS)

    Liu Changsheng; Zheng Xiaohua; Li Maojing; Wei Wenzhou; Pan Ewu; Tang Guangqiao; Zhang Duanlian

    2006-01-01

    Objective: To optimize the CT scanning parameters in pediatric temporal bone examination with artificial cochlear implant and reduce its radiation hazards. Methods: The temporal bones of 87 patients with suspected inner ear disease which include 31 experienced artificial cochlear implant were scanned by HRCT. Regarding adult scan parameters as a criteria, properly adjusted the scanning dose and scanning angle until the quality of CT images was beyond the diagnosis demands. Finally the exposed doses, single scanning CT dose index weighted (CTDI w ) and dose length product (DLP) were analysed. Results: Compared with adult temporal bone scanning, the exposure value and CTDI w were reduced to 66.67%-83.33%, DLP of temporal bone scanning in pediatrics was reduced to 66.67%-83.33%, moreover, the imaging quality of tridimensional reconstruction for inner ear and implant electrode was improved. Conclusion: The proper reduction of CT scan exposure on preoperative and postoperative children with cochlear implants and the proper adjustment of scan angle can significantly reduce the exposure dose to local temporal bone and effectually avoid the damage to lens of children. (authors)

  20. Preoperative Radiographic and CT Findings Predicting Syndesmotic Injuries in Supination-External Rotation-Type Ankle Fractures.

    Science.gov (United States)

    Choi, Young; Kwon, Soon-Sun; Chung, Chin Youb; Park, Moon Seok; Lee, Seung Yeol; Lee, Kyoung Min

    2014-07-16

    The Lauge-Hansen classification system does not provide sufficient data related to syndesmotic injuries in supination-external rotation (SER)-type ankle fractures. The aim of the present study was to investigate factors helpful for the preoperative detection of syndesmotic injuries in SER-type ankle fractures using radiographs and computed tomography (CT). A cohort of 191 consecutive patients (104 male and eighty-seven female patients with a mean age [and standard deviation] of 50.7 ± 16.4 years) with SER-type ankle fractures who had undergone operative treatment were included. Preoperative ankle radiographs and CT imaging scans were made for all patients, and clinical data, including age, sex, and mechanism of injury (high or low-energy trauma), were collected. Patients were divided into two groups: the stable syndesmotic group and the unstable syndesmotic group, with a positive intraoperative lateral stress test leading to syndesmotic screw fixation. Fracture height, fracture length, medial joint space, extent of fracture, and bone attenuation were measured on radiographs and CT images and were compared between the groups. Binary logistic regression analysis was performed to identify the factors that significantly contributed to unstable syndesmotic injuries. Receiver operating characteristic curves were calculated, and cutoff values were suggested to predict unstable syndesmotic injuries on preoperative imaging measurements. Of the 191 patents with a SER-type ankle fracture, thirty-eight (19.9%) had a concurrent unstable syndesmotic injury. Age, sex, mechanism of injury, fracture height, medial joint space, and bone attenuation were significantly different between the two groups. In the binary logistic analysis, fracture height, medial joint space, and bone attenuation were found to be significant factors contributing to unstable syndesmotic injuries. The cutoff values for predicting unstable syndesmotic injuries were a fracture height of >3 mm and a medial

  1. The diagnostic value of CT scan and selective venous sampling in Cushing's syndrome

    International Nuclear Information System (INIS)

    Negoro, Makoto; Kuwayama, Akio; Yamamoto, Naoto; Nakane, Toshichi; Yokoe, Toshio; Kageyama, Naoki; Ichihara, Kaoru; Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    We studied 24 patients with Cushing's syndrome in order to find the best way to confirm the pituitary adenoma preoperatively. At first, the sellar content was studied by means of a high-resolution CT scan in each patient. Second, by selective catheterization in the bilateral internal jugular vein and the inferior petrosal sinus, venous samples (c) were obtained for ACTH assay. Simultaneously, peripheral blood sampling (P) was made at the anterior cubital vein for the same purpose, and the C/P ratio was carefully calculated in each patient. If the C/P ratio exceeded 2, it was highly suggestive of the presence of pituitary adenoma. Even by an advanced high-resolution CT scan with a thickness of 2 mm, pituitary adenomas were detected in only 32 % of the patients studied. The result of image diagnosis in Cushing disease was discouraging. As for the chemical diagnosis, the results were as follows. At the early stage of this study, the catheterization was terminated in the jugular veins of nine patients. Among these, in five patients the presence of pituitary adenoma was predicted correctly in the preoperative stage. Later, by means of inferior petrosal sinus samplings, pituitary microadenomas were detected in ten patients among the twelve. Selective venous sampling for ACTH in the inferior petrosal sinus or jugular vein proved to be useful for the differential diagnosis of Cushing's syndrome when other diagnostic measures such as CT scan were inconclusive. (author)

  2. Case of asymmetrical arthrogryposis. A clinical study and a preliminary report on the value of CT-scanning

    Energy Technology Data Exchange (ETDEWEB)

    Hageman, G.; Vette, J.K.; Willemse, J. (University Hospital, Utrecht (Netherlands))

    1983-01-01

    Following the introduction of the conception that arthrogryposis is a symptom and not a clinical entity, a case of the very rare asymmetric form of neurogenic arthrogryposis is presented. The asymmetry of congenital contractures and weakness is associated with hemihypotrophy. The value of muscular CT-scanning prior to muscle biopsy is demonstrated. Muscular CT-scanning shows the extension of adipose tissue, which has replaced damaged muscles and therby indicates the exact site for muscle biopsy. Since orthopaedic treatment in arthrogryposis can be unrewarding due to severe muscular degeneration, preoperative scanning may provide additional important information on muscular function and thus be of benefit for surgery. The advantage of muscular CT-scanning in other forms of arthrogryposis requires further determination. The differential diagnosis with Werdnig-Hoffmann disease is discussed.

  3. Clinical value of CT-based preoperative software assisted lung lobe volumetry for predicting postoperative pulmonary function after lung surgery

    Science.gov (United States)

    Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter

    2005-04-01

    This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.

  4. Renal Tumor Cryoablation Planning. The Efficiency of Simulation on Reconstructed 3D CT Scan

    Directory of Open Access Journals (Sweden)

    Ciprian Valerian LUCAN

    2010-12-01

    Full Text Available Introduction & Objective: Nephron-sparing surgical techniques risks are related to tumor relationships with adjacent anatomic structures. Complexity of the renal anatomy drives the interest to develop tools for 3D reconstruction and surgery simulation. The aim of the article was to assess the simulation on reconstructed 3D CT scan used for planning the cryoablation. Material & Method: A prospective randomized study was performed between Jan. 2007 and July 2009 on 27 patients who underwent retroperitoneoscopic T1a renal tumors cryoablation (RC. All patients were assessed preoperatively by CT scan, also used for 3D volume rendering. In the Gr.A, the patients underwent surgery planning by simulation on 3D CT scan. In the Gr.B., patients underwent standard RC. The two groups were compared in terms of surgical time, bleeding, postoperative drainage, analgesics requirement, hospital stay, time to socio-professional reintegration. Results: Fourteen patients underwent preoperative cryoablation planning (Gr.A and 13 patients underwent standard CR (Gr.B. All parameters analyzed were shorter in the Gr.A. On multivariate logistic regression, only shortens of the surgical time (138.79±5.51 min. in Gr.A. vs. 140.92±5.54 min in Gr.B. and bleeding (164.29±60.22 mL in Gr.A. vs. 215.38±100.80 mL in Gr.B. achieved statistical significance (p<0.05. The number of cryoneedles assessed by simulation had a 92.52% accuracy when compared with those effectively used. Conclusions: Simulation of the cryoablation using reconstructed 3D CT scan improves the surgical results. The application used for simulation was able to accurately assess the number of cryoneedles required for tumor ablation, their direction and approach.

  5. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  6. Contribution of brain imaging techniques: CT-scan and magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Pasco-Papon, A.; Gourdier, A.L.; Papon, X.; Caron-Poitreau, C.

    1996-01-01

    In light of the current lack of consensus on the benefit of carotid artery surgery to treat asymptomatic carotid artery stenosis, the decision to operate on a patient depends on individual evaluation and characterization of risk factors on carotid artery stenosis greater than 70 %. The assessment of such risk factors is based especially on non-invasive brain imaging techniques.Computed tomography scanning (CT-scan) and magnetic resonance imaging (MRI) enable two types of stenosis to be differentiated, i.e. stenoses which are symptomatic and those that are radiologically proven versus those which are clinically and radiologically silent. CT-scan investigation (with and without injection of iodinated contrast media) still continues to be a common routine test in 1996 whenever a surgical revascularization procedure is planned. The presence of deep lacunar infarcts ipsilateral to the carotid artery stenosis generally evidence the reality of stenosis and thus are useful to the surgeon in establishing whether surgery is indicated. In the absence a consensus on indications for surgical management, the surgeon could use the CT-scan and MRI as medicolegal records which could be compared to a subsequent postoperative CT-scan in case of ischemic complications associated with the surgical procedure. Furthermore, recent cerebral ischemia as evidenced by filling with contrast material, will call for postponing treatment by a few weeks. Although conventional MRI is more contributive than brain CT-scan in terms of sensibility and specificity, its indications are narrower because of its limited availability and cost constraints. But, development of angio-MRI and functional imaging promise that its future is assured and even perhaps as the sole diagnostic method if its indications are expanded to include preoperative angiographic evaluation of atheromatous lesions of supra-aortic trunks. (authors). 37 refs

  7. Aneurysms of proximal pulmonary arteries: CT diagnosis and preoperative assessment

    International Nuclear Information System (INIS)

    Iula, G.; Ziviello, R.; Del Vecchio, W.

    1996-01-01

    We reviewed our experience with proximal pulmonary artery aneurysm (PPAA) to determine whether accurate preoperative evaluation (crucial to differential diagnosis and surgical planning) had been obtained on the basis of CT study alone. Three patients with PPAA were studied with contrast-enhanced CT. We evaluated the size and shape of PPAAs, their proximal and distal extent, eventual presence of intraluminal thrombi, dissection, perianeurysmal fibrosis, and rupture. The results were compared with surgical findings. In two patients the aneurysm involved the pulmonary trunk and both the right and left arteries origin. In one patient the aneurysm extended from the left artery origin to the hilum of the left lung. Contrast-enhanced CT alone allows detection of aneurysm in the pulmonary trunk, in right or left pulmonary arteries with precise preoperative evaluation of the extent, size, shape, and complications. The CT imaging was unable to establish the etiologic origin and presence of small intimal tears in PPAA. (orig.)

  8. Comparison of CT and 18F-FDG PET for Detecting Peritoneal Metastasis on the Preoperative Evaluation for Gastric Carcinoma

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Kim, Myeong Jin; Yun, Mi jin

    2006-01-01

    The aim of our study was to compare the accuracy of CT and 18 F-FDG PET for detecting peritoneal metastasis in patients with gastric carcinoma. One-hundred-twelve patients who underwent a histologic confirmative exam or treatment (laparotomy, n = 107; diagnostic laparoscopy, n = 4; peritoneal washing cytology, n = 1) were retrospectively enrolled. All the patients underwent CT and 18 F-FDG PET scanning for their preoperative evaluation. The sensitivities, specificities and accuracies of CT and 18 FFDG PET imaging for the detection of peritoneal metastasis were calculated and then compared using Fisher's exact probability test (p 18 F-FDG PET imaging for detecting peritoneal metastasis. Based on the original preoperative reports, CT and 18 F-FDG PET showed sensitivities of 76.5% and 35.3% (p = 0.037), specificities of 91.6% and 98.9% (p = 0.035), respectively, and equal accuracies of 89.3% (p = 1.0). The receptor operating characteristics curve analysis showed a significantly higher diagnostic performance for CT (Az 0.878) than for PET (Az = 0.686) (p 0.004). The interobserver agreement for detecting peritoneal metastasis was good (κ value = 0.684) for CT and moderate ((κ value = 0.460) for PET. For the detection of peritoneal metastasis, CT was more sensitive and showed a higher diagnostic performance than PET, although CT had a relatively lower specificity than did PET

  9. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  10. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  11. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  12. Preoperative nuclear scans in patients with melanoma

    International Nuclear Information System (INIS)

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-01-01

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive

  13. Single-Blinded Prospective Implementation of a Preoperative Imaging Checklist for Endoscopic Sinus Surgery.

    Science.gov (United States)

    Error, Marc; Ashby, Shaelene; Orlandi, Richard R; Alt, Jeremiah A

    2018-01-01

    Objective To determine if the introduction of a systematic preoperative sinus computed tomography (CT) checklist improves identification of critical anatomic variations in sinus anatomy among patients undergoing endoscopic sinus surgery. Study Design Single-blinded prospective cohort study. Setting Tertiary care hospital. Subjects and Methods Otolaryngology residents were asked to identify critical surgical sinus anatomy on preoperative CT scans before and after introduction of a systematic approach to reviewing sinus CT scans. The percentage of correctly identified structures was documented and compared with a 2-sample t test. Results A total of 57 scans were reviewed: 28 preimplementation and 29 postimplementation. Implementation of the sinus CT checklist improved identification of critical sinus anatomy from 24% to 84% correct ( P identification of sinus anatomic variants, including those not directly included in the systematic review implemented. Conclusion The implementation of a preoperative endoscopic sinus surgery radiographic checklist improves identification of critical anatomic sinus variations in a training population.

  14. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  15. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  16. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  17. From CT scanning to 3-D printing technology for the preoperative planning in laparoscopic splenectomy.

    Science.gov (United States)

    Pietrabissa, Andrea; Marconi, Stefania; Peri, Andrea; Pugliese, Luigi; Cavazzi, Emma; Vinci, Alessio; Botti, Marta; Auricchio, Ferdinando

    2016-01-01

    Three-dimensional printing technology is rapidly changing the way we produce all sort of objects, having also included medical applications. We embarked in a pilot study to assess the value of patient-specific 3-D physical manufacturing of spleno-pancreatic anatomy in helping during patient's counseling and for preoperative planning. Twelve patients scheduled for a laparoscopic splenectomy underwent contrast CT and subsequent post-processing to create virtual 3-D models of the target anatomy, and 3-D printing of the relative solid objects. The printing process, its cost and encountered problems were monitored and recorded. Patients were asked to rate the value of 3-D objects on a 1-5 scale in facilitating their understanding of the proposed procedure. Also 10 surgical residents were required to evaluate the perceived extra value of 3-D printing in the preoperative planning process. The post-processing analysis required an average of 2; 20 h was needed to physically print each model and 4 additional hours to finalize each object. The cost for the material employed for each object was around 300 euros. Ten patients gave a score of 5, two a score of 4. Six residents gave a score of 5, four a score of 4. Three-dimensional printing is helpful in understanding complex anatomy for educational purposes at all levels. Cost and working time to produce good quality objects are still considerable.

  18. The value of multi-slice spiral CT in the preoperative assessment of living renal donor

    International Nuclear Information System (INIS)

    Li Qinghai; Yan Fuhua; Xu Pengju; Zhou Meiling; Zhu Tongyu; Xu Ming; Wang Guomin

    2008-01-01

    Objective: The purpose of this study is to assess the value of multi-slice spiral CT (MSCT) in the preoperative evaluation of living renal donor as a all in one modality. Methods: Thirty-six potential living renal donors underwent the examination using a GE light VCT scanner. Informed consent was obtained from all participants. The plain scan, early arterial phase, late arterial phase and excretory phase scans are performed in the former 25 donors (injection rate 5 rolls, total volume 100 mi, tube tension 120 kV). While in the later 11 donors (2 ml/s 40 ml +4 ml/s 60 ml), the scanning protocol included the plain scan ( 100 kV), vascular phase and excretory phase scans (100 kV). The excretory phase data were used in the reconstruction of CT urography in both groups. All images were reviewed by one radiologist and one urologist, and the findings of MSCT were compared with intraoperative findings for 33 donors, to investigate the utilities of MSCT in assessing renal vascularity, urinary tract and lesions of renal parenchyma. When discrepancies are found between the two reviewers, consensus was obtained via discussion. Au data was statiscally processed with SPSS for Windows. Results: MSCT angiography is in accordance with intraoperative findings in demonstrating the anatomy of renal arteries and renal vein trunk, accesary arteries, early branching of renal artery. The findings from CTA are highly in accordance with the intraoperative findings, which facilitate intraoperative ligation and reduce relevant complications. CTU demonstrates the anatomy of urinary, tract in good agreement with the intraoperative findings. The image quality of 3D vascularity and CTU between the two groups, scored 4.4 ± 1.2 vs 4.2 ± 1.3 and 4.6 ± 0.8 vs 4.4 ± 0.9 respectively, no statistical between-groups difference was found (Z=-0.89, -0.47, P>0.05). Conclusion: MSCT multiphase scanning combined with CTA and CTU play a important role in the evaluation of living renal donor, which

  19. Colonoscopy and computerised tomography scan are not sufficient to localise right sided colonic lesions accurately.

    LENUS (Irish Health Repository)

    Solon, Jacqueline Gemma

    2009-11-23

    : Aim: accurate pre-operative localisation of colonic lesions is critical especially in laparoscopic colectomy where tactile localisation is absent particularly in screen-detected tumours. The study aimed to evaluate the accuracy of colonoscopy and double-contrast computerised tomography (CT) to localise lesions treated by right hemicolectomy. Method: a retrospective chart review was performed of patients treated by right hemicolectomy under the colorectal service between July 2003 and October 2006. Pre-operative tumour location determined by CT scan and colonoscopy were compared with the intra-operative and histopathologic findings. Results: of 101 patients, 73 (73%) were for adenoma or cancer, with a final diagnosis of adenocarcinoma in 59 (59%). Pre-operative localisation was inaccurate in 29% of lesions using both CT and colonoscopy. In the transverse colon colonoscopy alone was only 37.5% accurate, increasing to 62.5% when information from the CT scan was added. Conclusion: pre-operative localisation of right-sided colon cancers using colonoscopy and CT scanning is unreliable in at least 29% of cases. Inaccurate localisation of transverse colon tumours risks inadequate lymphadenectomy with an adverse cancer outcome. Pre-operative abdominal CT scan improves accuracy but endoscopic tattoo localisation should be employed routinely especially in patients undergoing laparoscopic resection.

  20. Usefulness of preoperative chest multidetector CT for evaluation of breast cancer: comparison with breast MRI

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Kim, Dong Hun; Lee, Min Hyuk

    2005-01-01

    To evaluate the efficacy of chest multidetector-row helical computed tomography (MDCT) in detecting breast cancer in preoperative metastasis work-ups and to assess the accuracy of MDCT compared with magnetic resonance imaging (MRI). MDCT were performed on 69 consecutive patients with 94 lesions of histologically proven breast cancer. Retrospectively, two radiologists performed a blind review of the MDCT images for margin, shape, mass enhancement pattern and the enhancing distribution of non-mass lesions with consensus. CT attenuation values were measured in the average HU on pre-enhancing and enhanced CT in gland, fat, muscle, and in masses with the largest region of interest (ROI). MDCT finding were analyzed and compared with breast MRI. Of the 91 breast lesions detected on MDCT, 64 were mass lesions and 24 were non-mass lesions on enhancement, 86 lesions were malignant and 5 were benign. Three pathologically proven malignant masses were not detected on MDCT. Positive predictive value, false positive rate and false negative rate were 94.5%, 5.3%, 3.2% respectively. The highly predictive features for malignancy were a spiculated or irregular margin, an irregular of round shape, and a heterogeneously or rim enhanced mass. Another highly predictive feature for malignancy was linear or segmentally distributed enhancing non-mass lesions. The CT values of masses in pre-enhanced scans were 38.6 ± 7.9 HU; these values increased to 110.9 ± 26.6 HU after contrast injection (90 sec). The attenuation values from enhancing CT of malignant lesions were significantly higher than those of non-enhancing lesions. The depiction of enhancing masses on MDCT compared with MR imaging were 88.6%. The extension of malignancy were equally well correlated MDCT with MR imaging. The diagnostic value of chest MDCT for preoperative staging is comparable with MR imaging for the detection and extension of lesions. Therefore, chest MDCT of breast cancer can add to the information obtained from

  1. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  2. CT detection of thyroid pyramidal lobe in preoperative patients with thyroid tumors

    International Nuclear Information System (INIS)

    Shin, Gi Won; Kim, Dong Won

    2013-01-01

    Thyroid pyramidal lobe (TPL) is a normal variant of the thyroid gland, but few imaging studies of TPL have been published. The purpose of this study is to investigate the frequency, location, size (length, maximal AP diameter, maximal transverse diameter), and upper end level of TPL with its separation from the main thyroid gland on preoperative neck CT and to compare them with operative findings in order to assess the diagnostic accuracy of neck CT for detection TPL. 46 patients, who underwent preoperative neck CT before thyroidectomy, were included in the study. The frequency, location, size, and upper end level of TPL with its separation from the main thyroid gland on the neck CT was analyzed by a single radiologist. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of neck CT for detecting TPL was 77.8%, 89.5%, 91.3%, 73.9% and 82.6%. There was a significant difference in maximal AP diameter, location, upper end level, and its separation from main thyroid gland between CT and operative findings (p 0.05). Diagnostic accuracy of neck CT for detecting TPL was high, and the neck CT may be useful for evaluating TPL in the suprahyoid neck.

  3. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration. [Preoperative scanning

    Energy Technology Data Exchange (ETDEWEB)

    Heslinga, J M; Pauwels, E K.J.; Zwaveling, A [Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis

    1982-06-05

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period.

  4. Preoperative staging of lung cancer with PET/CT: cost-effectiveness evaluation alongside a randomized controlled trial

    International Nuclear Information System (INIS)

    Soegaard, Rikke; Fischer, Barbara Malene B.; Mortensen, Jann; Hoejgaard, Liselotte; Lassen, Ulrik

    2011-01-01

    Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost-effectiveness. The objective of this study was to assess the cost-effectiveness of PET/CT as an adjunct to conventional workup for preoperative staging of NSCLC. The study was conducted alongside an RCT in which 189 patients were allocated to conventional staging (n = 91) or conventional staging + PET/CT (n = 98) and followed for 1 year after which the numbers of futile thoracotomies in each group were monitored. A full health care sector perspective was adapted for costing resource use. The outcome parameter was defined as the number needed to treat (NNT) - here number of PET/CT scans needed - to avoid one futile thoracotomy. All monetary estimates were inflated to 2010 EUR. The incremental cost of the PET/CT-based regimen was estimated at 3,927 EUR [95% confidence interval (CI) -3,331; 10,586] and the NNT at 4.92 (95% CI 3.00; 13.62). These resulted in an average incremental cost-effectiveness ratio of 19,314 EUR, which would be cost-effective at a probability of 0.90 given a willingness to pay of 50,000 EUR per avoided futile thoracotomy. When costs of comorbidity-related hospital services were excluded, the PET/CT regimen appeared dominant. Applying a full health care sector perspective, the cost-effectiveness of PET/CT for staging NSCLC seems to depend on the willingness to pay in order to avoid a futile thoracotomy. However, given that four outliers in terms of extreme comorbidity were all randomized to the PET/CT arm, there is uncertainty about the conclusion. When hospital costs of comorbidity were excluded, the PET/CT regimen was found to be both more accurate and cost saving. (orig.)

  5. Usefulness of preoperative three dimensional CT in laparoscopic cholecystectomy. Especially, its comparison to ERC

    International Nuclear Information System (INIS)

    Machida, Hiromichi; Nakaya, Yuzou; Kojima, Kojirou

    1996-01-01

    We studied the usefulness of three dimensional helical CT (3D-CT) combined with drip infusion cholangiography for determining the application of laparoscopic cholecystectomy (LC) and evaluating the cholecyst severity. The subjects were 56 patients who underwent LC with preoperative 3D-CT. Particularly, in 42 patients undergoing endoscopic retrograde cholangiography (ERC) and 3D-CT simultaneously, the results with both methods were compared. The detection rates of the original site, forward and backward direction, and left and right direction in the confluence form of the cystic duct by means of 3D-CT versus ERC were 100% vs. 92.9% 92.9% vs. 71.4%, and 92.9% vs. 88.1%, respectively. Abnormal biliary distribution was visualized in 5 cases and all of them were depicted by 3D-CT. The 3D-CT was superior to ERC in terms of X-ray dose and cost. These results indicate the usefulness of 3D-CT as a LC preoperative examination. (author)

  6. Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahmoud Jabalameli

    2016-04-01

    Full Text Available Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. Methods: One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. Results: The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Conclusion: Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be

  7. Diagnosis of gynecologic pelvic masses by CT scans

    International Nuclear Information System (INIS)

    Ito, Hisao; Kubo, Atsushi; Takagi, Yaeko; Kinoshita, Fumio; Maekawa, Akira.

    1981-01-01

    Two hundred eighty four patients with gynecologic pelvic masses were evaluated with CT scans. Of the patients, 196 had subsequent surgical determination of abnormalities and pathological proof of diagnosis was obtained. Only these 196 patients were included in this study. The CT scans could provide correct diagnosis in 113 of 114 (99%) patients with benign uterine tumor and in all (100%) patients with either serous cystadenoma or dermoid cyst. However, evaluation of mucinous cystadenoma (44%) and endometriosis cyst (37%) by CT scan has some limitations. It was difficult to differentiate mucinous cystadenoma from ovarian carcinoma, because both lesions had partial multiloculation and solid-like areas in the cyst. The CT findings of endometriosis cyst had similarity with serous cystadenoma, and 5 of 8 patients with this disease were diagnosed as serous cystadenoma. Ovarian fibroma and endometrial cancer were also not determined by CT scans. CT identified 87% of patients with ovarian cancer, while false positive rate of this disease was 38% (8/21). In 6 of 13 patients with both of leiomyoma and ovarian cyst, CT was able to demonstrate ovarian lesions that were overlooked by bimanual examinations. The role of CT scanning in our clinical practice is discussed. (author)

  8. Assessing the registration of CT-scan data to intraoperative x rays by fusing x rays and preoperative information

    Science.gov (United States)

    Gueziec, Andre P.

    1999-05-01

    This paper addresses a key issue of providing clinicians with visual feedback to validate a computer-generated registration of pre-operative and intra-operative data. With this feedback information, the clinician may decide to proceed with a computer-assisted intervention, revert to a manual intervention, or potentially provide information to the computer system to improve the registration. The paper focuses on total hip replacement (THR) surgery, but similar techniques could be applied to other types of interventions or therapy, including orthopedics, neurosurgery, and radiation therapy. Pre-operative CT data is used to plane the surgery (select an implant type, size and precise position), and is registered to intra-operative X-ray images, allowing to execute the plan: mill a cavity with the implant's shape. (Intra-operative X-ray images must be calibrated with respect to the surgical device executing the plan). One novel technique presented in this paper consists of simulating a post-operative X-ray image of the tissue of interest before doing the procedure, by projecting the registered implant onto an intra-operative X- ray image (corrected for distortion or not), providing clinicians with familiar and easy to interpret images. As an additional benefit, this method provides new means for comparing various strategies for registering pre-operative data to the physical space of the operating room.

  9. CT scan of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, T; Noguchi, S; Nishitani, H [National Sanatorium of Utano, Kyoto (Japan); Kitano, H; Ikegami, Y

    1981-04-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs.

  10. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    Konishi, Tetsuro; Noguchi, Sadako; Nishitani, Hiroshi; Kitano, Haruo; Ikegami, Yoshinori.

    1981-01-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  11. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  12. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  13. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  14. Dynamic helical CT mammography of breast cancer

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Fukushima, Hitoshi; Okamura, Ryuji; Nakamura, Yoshiaki; Morimoto, Taisuke; Urata, Yoji; Mukaihara, Sumio; Hayakawa, Katsumi

    2006-01-01

    The purpose of this study was to determine whether dynamic helical computed tomography (CT)-mammography could assist in selecting the most appropriate surgical method in women with breast cancer. Preoperative contrast-enhanced helical CT scanning of the breast was performed on 133 female patients with suspicion of breast cancer at the same time as clinical, mammographic, and/or ultrasonographic examinations. The patients were scanned in the prone position with a specially designed CT-compatible device. A helical scan was made with rapid intravenous bolus injection (3 ml/s) of 100 ml of iodine contrast material. Three-dimensional maximum intensity projection (MIP) images were reconstructed, and CT findings were correlated with surgical and histopathological findings. Histopathological analysis revealed 84 malignant lesions and seven benign lesions. The sensitivity, specificity, and accuracy levels of the CT scanning were 94.6%, 58.6%, and 78.9%. Helical scanning alone revealed additional contralateral carcinomas in three of four patients and additional ipsilateral carcinomas in three of five patients. However, the technique gave false-positive readings in 24 patients. The preoperative CT-mammogram altered the surgical method in six patients. Dynamic helical CT-mammography in the prone position may be one of the choices of adjunct imaging in patients with suspected breast cancer scheduled for surgery. (author)

  15. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  16. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  17. CT scan for the diagnosis of maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Kimura, Yo; Kato, Isao; Aoyagi, Masaru; Kikuchi, Akira; Koike, Yoshio; Suzuki, Hachiro.

    1984-01-01

    A comparative study between the conventional radiological examination and the computed tomographical examination for the diagnosis of maxillary sinus carcinoma was done. CT scan has been more appreciated to detect the tumor invasion in the pterygopalatine fossa, orbit, posterior ethmoid sinus and skull base than the conventional examination. CT scan was most usefull for the determination of size and location of the tumor. The prognosis by the stage-grouping was significantly separated by the new classification with CT scan. Therefore, new TNM classification of maxillary sinus carcinoma with CT scan should be taken into account. (author)

  18. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  19. Perforated appendicitis: accuracy of CT diagnosis and correlation of CT findings with the length of hospital

    International Nuclear Information System (INIS)

    Siddiqui, H.A.; Afzal, S.

    2007-01-01

    To determine the sensitivity and specificity of CT findings in the differentiation of perforated from nonperforated appendicitis and correlate CT diagnosis with the length of hospital stay. The study included 70 patients who presented with right lower quadrant abdominal pain and underwent preoperative CT scan followed by appendectomy. Patients were divided into two groups of having perforated and nonperforated appendicitis on the basis of CT scan findings. The surgical and pathological reports combined were considered the reference standard for the diagnosis of perforated appendicitis. Various CT scan findings and average duration of hospital stay in days was compared by t-test. Twenty-six (37%) of 70 patients had perforated appendicitis. It was correctly identified on pre-operative CT scan in 18 patients. There were 18 true positive diagnoses, 43 true negative diagnoses, 1 false positive diagnosis and 8 false negative diagnoses which yielded a sensitivity of 69%, specificity of 97%, positive predictive value of 94% and negative predictive value of 84%. Mean length of hospital stay in perforated group was 6.3 days and 2.9 days in nonperforated group. Severe periappendiceal inflammation, periappendiceal and or abdominopelvic fluid and abscess were significantly associated with perforated appendicitis and with a significant longer hospital stay (p <.001). CT scan is 69% sensitive and 97% specific for the diagnosis of perforated appendicitis and constellation of CT findings can be used to select patients with perforated appendicitis for initial non-operative management. Presence of CT signs of significant appendiceal inflammation is independent predictor of longer hospital stay. (author)

  20. The correlation of preoperative CT, MR imaging, and clinical staging (FIGO) with histopathology findings in primary cervical carcinoma

    International Nuclear Information System (INIS)

    Oezsarlak, Oe.; Schepens, E.; Corthouts, B.; Beeck, B.O. de; Parizel, P.M.; De Schepper, A.M.; Tjalma, W.; Marck, E. van

    2003-01-01

    The aim of this study was to compare the preoperative findings of abdominal/pelvic CT and MRI with the preoperative clinical International Federation of Obstetrics and Gynecology (FIGO) staging and postoperative pathology report in patients with primary cancer of the cervix. Thirty-six patients with surgical-pathological proven primary cancer of the cervix were retrospectively studied for preoperative staging by clinical examination, CT, and MR imaging. Studied parameters for preoperative staging were the presence of tumor, tumor extension into the parametrial tissue, pelvic wall, adjacent organs, and lymph nodes. The CT was performed in 32 patients and MRI (T1- and T2-weighted images) in 29 patients. The CT and MR staging were based on the FIGO staging system. Results were compared with histological findings. The group is consisted of stage 0 (in situ):1, Ia:1, Ib:8, IIa:2, IIb:12, IIIa:4, IVa:6, and IVb:2 patients. The overall accuracy of staging for clinical examination, CT, and MRI was 47, 53, and 86%, respectively. The MRI incorrectly staged 2 patients and did not visualize only two tumors; one was an in situ (stage-0) and one stage-Ia (microscopic) disease. The MRI is more accurate than CT and they are both superior to clinical examination in evaluating the locoregional extension and preoperative staging of primary cancer of the cervix. (orig.)

  1. Multidetector computed tomography for the assessment of adnexal Mass: Is unenhenced CT scan necessary?

    International Nuclear Information System (INIS)

    Jung, Sung Il; Park, Hee Sun; Kim, Young Jun; Jeon, Hae Jeong

    2014-01-01

    To compare the diagnostic performance and radiation dose between contrast-enhanced CT (ECT) alone, and combined unenhanced and contrast-enhanced CT (UE + ECT) for the assessment of adnexal mass. This retrospective study was approved by the Institutional Review Board. A total of 146 consecutive patients (mean age, 41.1 years) who underwent preoperative unenhanced and contrast-enhanced multidetector CT of the pelvis and had adnexal masses found at surgery were included. Two readers independently evaluated the likelihood of adnexal malignancy on a 5-point scale on two different imaging datasets (ECT alone and UE + ECT). The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Radiation dose to patients was calculated by the volume CT dose index (CTDIvol) and the dose length products (DLP) on each dataset. Of the total 178 adnexal masses, 133 masses were benign and 45 masses were malignant. For both readers, there is no significant difference of AUC values between ECT alone and UE + ECT for the detection of adnexal malignancy (reader 1, 0.93 vs. 0.95; reader 2, 0.92 vs. 0.91) (p > 0.05). The mean CTDIvol (12.6 ± 2.2 mGy) and DLP (641.2 ± 137.2 mGy) of ECT alone was significantly lower than the mean CTDIvol (21.5 ± 2.7 mGy) and DLP (923.6 ± 158.8 mGy) of UE + ECT (p < 0.0001). The use of unenhanced CT scan in addition to contrast-enhanced CT scan does not improve the detection of adnexal malignancy, but increases radiation exposure.

  2. Clinical significance of CT in the preoperative diagnosis of the staging of rectal cancer patients

    International Nuclear Information System (INIS)

    Itano, Satoshi; Fuchimoto, Sadanori; Hamada, Fumihiro; Kimura, Takanobu; Iwagaki, Hiromi; Maeda, Tetsuya; Orita, Kunzo

    1987-01-01

    The value of computed tomography (CT) in the preoperative clinical staging of rectal cancer was prospectively studied in 28 patients with macroscopically proven cancer. The CT studies were based on the previously established CT diagnostic criteria for wall invasion (S factor), lymph node metastases (N factor), and liver metastases (H factor). When macroscopic findings were used as the standard, the accuracy of CT was 61 % for S factor, 32 % for N factor, and 86 % for H factor. Using histological findings as the standard, the accuracy was 48 % for S factor and 16 % for N factor. Overall, CT had a high accuracy for H factor in all sites of cancer (75 % in the rectosigmoid, 86 % in the area above the peritoneal reflection, and 90 % in the area below the peritoneal reflection). For the other S and N factors, CT seemed to be of limited value in the preoperative diagnosis. (Namekawa, K.)

  3. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  4. Preoperative staging of rectal cancer by magnetic resonance imaging (MRI) and computed tomography (CT)

    International Nuclear Information System (INIS)

    Itabashi, Michiaki; Kameoka, Shingo; Nakajima, Kiyotaka; Izumi, Kiminari; Miyazaki, Kaname; Hamano, Kyoichi; Kouno, Atsushi

    1991-01-01

    To clarify the usefulness and limitations of CT and MRI in preoperative assessment of the wall invasion of rectal cancer, we compared the results of CT and MRI with the histopathological findings, classifying tumors by the region and site in 34 patients with rectal cancer. Subjects were patients preoperatively examined by MRI and CT. Overall, the percent of cases with the extent of invasion accurately assessed by MRI was 88.2%, and that by CT was 64.7%. In all instances of wrong assessment, the extent of invasion was overestimated. The accurate assessment rate was significantly higher for MRI than for CT. After classification by the region, the accurate assessment rate at Rs was low as 50% for both MRI and CT because slices were not perpendicular to the tumor. The accurate assessment rate was 100% for MRI and 82% for CT at Ra, and respectively 94% and 59% at Rb. The majority of tumors at Ra or Rb centering on the lateral wall of the rectum were accurately assessed either by MRI or CT. With tumors at Ra or Rb (particularly Rb) centering on the anterior or posterior wall, CT frequently failed to identify the extent of invasion accurately, so that MRI seemed more suitable for these tumors. (author)

  5. CT diagnosis of annular pancreas

    International Nuclear Information System (INIS)

    Ueno, Eiko; Isobe, Yoshinori; Niimi, Akiko; Shimizu, Yasushi; Yamada, Akiyoshi; Hanyu, Fujio

    1987-01-01

    CT scan was performed in two cases of annular pancreas which could be found in one case preoperatively and in the other case retrospectively. CT scan demonstrated secondary changes of annular pancreas such as medial displacement and dilatation of the duodenal bulb in the former case and stenosis of the duodenal loop and thickened soft tissue density around the narrow segment of the duodenal loop in the latter case, although it failed to demonstrate the peninsular protrusion of the parenchyma of the pancreas head. These findings suggest high possibility of diagnosing annular pancreas by CT scan. (author)

  6. The Added Diagnostic Value of 18F-Fluorodihydroxyphenylalanine PET/CT in the Preoperative Work-Up of Small Bowel Neuroendocrine Tumors.

    Science.gov (United States)

    Addeo, Pietro; Poncet, Gilles; Goichot, Bernard; Leclerc, Loic; Brigand, Cécile; Mutter, Didier; Romain, Benoit; Namer, Izzie-Jacques; Bachellier, Philippe; Imperiale, Alessio

    2018-04-01

    The precise localization of the primary tumor and/or the identification of multiple primary tumors improves the preoperative work-up in patients with small bowel (SB) neuroendocrine tumor (NET). The present study assesses the diagnostic value of 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) positron emission tomography/computed tomography (PET/CT) during the preoperative wok-up of SB NETs. Between January 2010 and June 2017, all consecutive patients with SB NETs undergoing preoperative 18 F-FDOPA PET/CT and successive resection were analyzed. Preoperative work-up included computed tomography (CT), somatostatin receptor scintigraphy (SRS), and 18 F-FDOPA PET/CT. Sensitivity and accuracy ratio for primary and multiple tumor detection were compared with data from surgery and pathology. There were 17 consecutive patients with SB NETs undergoing surgery. Nine patients (53%) had multiple tumors, 15 (88%) metastatic lymph nodes, 3 (18%) peritoneal carcinomatosis, and 9 patients (53%) liver metastases. A total of 70 SB NETs were found by pathology. Surgery identified the primary in 17/17 (100%) patients and recognized seven of 9 patients (78%) with multiple synchronous SB. Preoperatively, 18 F-FDOPA PET/CT displayed a statistically significant higher sensitivity for primary tumor localization (100 vs. 23.5 vs. 29.5%) and multiple tumor detection (78 vs. 22 vs. 11%) over SRS and CT. Compared with pathology, 18 F-FDOPA PET/CT displayed the highest accuracy ratio for number of tumor detected over CT and SRS (2.0 ± 2.2 vs. 0.4 ± 0.7 vs. 0.6 ± 1.5, p = 0.0003). 18 F-FDOPA PET/CT significantly increased the sensitivity and accuracy for primary and multiple SB NET identification. 18 F-FDOPA PET/CT should be included systematically in the preoperative work-up of SB NET.

  7. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  8. Accuracy of 18F-FDG PET/CT for lymph node staging in non-small-cell lung cancers

    Institute of Scientific and Technical Information of China (English)

    LIU Bao-jun; DONG Jing-cheng; XU Chang-qing; ZUO Chuan-tao; LE Jing-jing; GUAN Yi-hui; ZHAO Jun; WU Jin-feng; DUAN Xiao-hong; CAO Yu-xue

    2009-01-01

    Background This retrospective study evaluated the diagnostic accuracy of 2-(F18)-fluoro-2-deoxy-D-glucose-positron emission tomography(18F-FDG-PET)/COmputed tomography(PET/CT)in the preoperative diagnosis of metastatic mediastinal and hilar lymph node in patients with non-small-cell lung cancer(NSCLC).Methods A total of 39 patients received preoperative 18F-FDG PET/CT and the postoperative biopsy.We compared preoperative PET/CT scan results with corresponding intraoperative histopathalogic findings in 39 NSCLC patients.The sensitivity,specificity,accuracy,positive and negative predictive value of 18F-FDG PET/CT were assessed.Results Histopathologic examination confirmed metastasis in 57 out of the 208 excised lymph nodes;23 of the 57 nodes were mediastinal and hilar lymph nodes.The sensitivity,specificity,accuracy,positive predictive value and negative predictive value of PET/CT in the preoperative diagnosis of mediastinal lymph node metastasis in NSCLC patients were 65%,96.8%,92%,78.5%and 90%,respectively.Conclusions PET/CT scan showed good accuracy in the preoperative diagnosis of mediastinal and hilar lymph node metastasis in the patients with NSCLC.We recommend that PET/CT scanning be used as a first-line evaluation tool for tumor diagnosis,therapy evaluation and follow-up.

  9. Value and clinical application of orthopedic metal artifact reduction algorithm in CT scans after orthopedic metal implantation

    International Nuclear Information System (INIS)

    Hu, Yi; Pan, Shinong; Zhao, Xudong; Guo, Wenli; He, Ming; Guo, Qiyong

    2017-01-01

    To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants

  10. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  11. FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

    International Nuclear Information System (INIS)

    Bassi, Maria Chiara; Turri, Lucia; Sacchetti, Gianmauro; Loi, Gianfranco; Cannillo, Barbara; La Mattina, Pierdaniele; Brambilla, Marco; Inglese, Eugenio; Krengli, Marco

    2008-01-01

    Purpose: To investigate the potential impact of using 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively

  12. Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models.

    Science.gov (United States)

    Rose, Austin S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Rawal, Rounak B; Iseli, Claire E

    2015-05-01

    As the process of additive manufacturing, or three-dimensional (3D) printing, has become more practical and affordable, a number of applications for the technology in the field of pediatric otolaryngology have been considered. One area of promise is temporal bone surgical simulation. Having previously developed a model for temporal bone surgical training using 3D printing, we sought to produce a patient-specific model for pre-operative simulation in pediatric otologic surgery. Our hypothesis was that the creation and pre-operative dissection of such a model was possible, and would demonstrate potential benefits in cases of abnormal temporal bone anatomy. In the case presented, an 11-year-old boy underwent a planned canal-wall-down (CWD) tympano-mastoidectomy for recurrent cholesteatoma preceded by a pre-operative surgical simulation using 3D-printed models of the temporal bone. The models were based on the child's pre-operative clinical CT scan and printed using multiple materials to simulate both bone and soft tissue structures. To help confirm the models as accurate representations of the child's anatomy, distances between various anatomic landmarks were measured and compared to the temporal bone CT scan and the 3D model. The simulation allowed the surgical team to appreciate the child's unusual temporal bone anatomy as well as any challenges that might arise in the safety of the temporal bone laboratory, prior to actual surgery in the operating room (OR). There was minimal variability, in terms of absolute distance (mm) and relative distance (%), in measurements between anatomic landmarks obtained from the patient intra-operatively, the pre-operative CT scan and the 3D-printed models. Accurate 3D temporal bone models can be rapidly produced based on clinical CT scans for pre-operative simulation of specific challenging otologic cases in children, potentially reducing medical errors and improving patient safety. Copyright © 2015 Elsevier Ireland Ltd. All rights

  13. Clinical and CT scan pictures of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Singounas, E.G.; Krassanakis, K.; Karvounis, P.C. (Evangelismos Hospital, Athens (Greece))

    1982-01-01

    The clinical presentations and CT scan pictures of four patients harbouring big cysticercus cysts are described. The value of CT scanning in detecting these cysts is emphasized, and also the fact that these cysts can behave as space-occyping lesions, which must be differentiated from other cystic formations.

  14. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  15. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Directory of Open Access Journals (Sweden)

    Paoli Alessandro

    2011-02-01

    Full Text Available Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast and preoperative (radiographic template models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology.

  16. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Science.gov (United States)

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  17. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  18. Chronic tuberculous empyema: relationships between preoperative CT findings and postoperative improvement measured by pulmonary function testing

    International Nuclear Information System (INIS)

    Kim, D.J.; Im, J.-G.; Goo, J.M.; Lee, H.J.; You, S.Y.; Song, J.W.

    2005-01-01

    AIMS: To evaluate whether preoperative computed tomography (CT) findings correlate with postoperative improvements in forced vital capacity (FVC) and forced expiratory volume during 1 s (FEV1) in persons who have undergone unilateral decortication because of unilateral chronic tuberculous empyema. METHODS: A retrospective study was carried out of 67 individuals who had undergone decortication because of chronic tuberculous empyema between January 1996 and December 2000. Of these, 13 subjects who had had preoperative chest CT and preoperative and postoperative pulmonary function tests (PFTs) were included in the investigation. On preoperative CT, the degree of volume reduction of the affected side was compared with that of the contralateral normal lung. The relative volume of empyema was calculated by dividing the volume occupied by the empyema by the sum of the total volume of the ipsilateral lung and the empyema volume. The thicknesses of pleura and extrapleural fat in the involved hemithorax were measured by CT at their thickest points, and the degree of atelectasis adjacent to the empyema in the diseased lung was assessed and classified. These five CT parameters and the ages of the patients were compared with preoperative and postoperative FVC and FEV1 changes. RESULTS: A significant negative correlation was found between FVC changes and the relative volume of the affected lung (FVC: p=0.039, RS=-0.58). FVC and FEV1 were found to be significantly and positively correlated with the relative volume of the empyema (FVC: p=0.005, RS=0.72; FEV1: p=0.014, RS=0.66) and the degree of atelectasis (FVC: p=0.007, RS=0.71; FEV1: p=0.029, RS=0.60) by Spearman's nonparametric correlation test. Other CT parameters and the ages of the patients were not found to be correlated with PFT changes. CONCLUSION: The relative volume of the affected side, the relative volume of empyema and the degree of atelectasis can predict improvements in FVC and FEV1 after decortication in patients

  19. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Layer, G.; Steudel, A.; Schild, H.H.; Schmitteckert, H.; Tuengerthal, S.; Schirren, J.; Kaick, G. van

    1999-01-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [de

  20. Diagnosis of pituitary adenoma by dynamic CT scanning

    International Nuclear Information System (INIS)

    Tanabe, Sumiyoshi; Uede, Teiji; Daibo, Masahiko; Niwa, Jun; Hashi, Kazuo

    1988-01-01

    The advantage of high resolution CT in the diagnosis of pituitary microadenomas has been established, but the diagnosis becomes more difficult when the pituitary microadenoma is less than 5 mm in diameter. We have studied the usefulness of dynamic CT scans particularly for diagnosis of small microadenomas. The dynamic CT scans were performed for 61 normal pituitary glands and 68 pituitary adenomas (36 microadenomas, 32 macroadenomas) with a GECT/T 9800 scanner. Coronal sections of 1.5 mm thickness were taken at the plane just in front of the pituitary stalk of the pituitary gland. Following a bolus intra-venous injection of 40 - 60 ml of contrast media using an automatic injector, ten consecutive CT scans of 2 seconds scan time were obtained, beginning 2 seconds from the start of intravenous injection. The first seven scans were taken with an interval of 2.3 seconds, and the last three scans with an interval of 10 seconds. Then, time-density curves were obtained at the ROI which were set on the anterior pituitary gland, the vascular bed of the pituitary gland, the pituitary stalk and the area of the pituitary adenoma respectively. In a normal pituitary gland, the density increases gradually and makes an S shaped curve, then attains the maximum density value (92.3 CT number) approximately 60 seconds after the administration of contrast media. The pituitary vascular bed is located in midline on the upper surface of the pituitary gland, and shows a symmetrical square, triangular or rhomboid shape. In case of pituitary adenoma, the time-density curve makes a plateau curve and attains the maximum density value (60.1 CT number) approximately 60 seconds after the administration of contrast media. In microadenoma, the pituitary vascular bed is either deformed or compressed, showing an asymmetrical shape. (author)

  1. CT pre-operative planning of a new semi-implantable bone conduction hearing device

    Energy Technology Data Exchange (ETDEWEB)

    Law, Eric K.C.; Bhatia, Kunwar S.S. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Hong Kong, SAR (China); Tsang, Willis S.S.; Tong, Michael C.F. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Otorhinolaryngology, Head and Neck Surgery, Hong Kong, SAR (China); Shi, Lin [The Chinese University of Hong Kong, Department of Medicine and Therapeutics, Hong Kong, SAR (China); The Chinese University of Hong Kong, Chow Yuk Ho Technology Center for Innovative Medicine, Hong Kong, SAR (China)

    2016-06-15

    Accommodating a novel semi-implantable bone conduction hearing device within the temporal bone presents challenges for surgical planning. This study describes the utility of CT in pre-operative assessment of such an implant. Retrospective review of pre-operative CT, clinical and surgical records of 16 adults considered for device implantation. Radiological suitability was assessed on CT using 3D simulation software. Antero-posterior (AP) dimensions of the mastoid bone and minimum skull thickness were measured. CT planning results were correlated with operative records. Eight and five candidates were suitable for device placement in the transmastoid and retrosigmoid positions, respectively, and three were radiologically unsuitable. The mean AP diameter of the mastoid cavity was 14.6 mm for the transmastoid group and 4.6 mm for the retrosigmoid group (p < 0.05). Contracted mastoid and/or prior surgery were predisposing factors for unsuitability. Four transmastoid and five retrosigmoid positions required sigmoid sinus/dural depression and/or use of lifts due to insufficient bone capacity. A high proportion of patients being considered have contracted or operated mastoids, which reduces the feasibility of the transmastoid approach. This finding combined with the complex temporal bone geometry illustrates the importance of careful CT evaluation using 3D software for precise device simulation. (orig.)

  2. Value and clinical application of orthopedic metal artifact reduction algorithm in CT scans after orthopedic metal implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yi; Pan, Shinong; Zhao, Xudong; Guo, Wenli; He, Ming; Guo, Qiyong [Shengjing Hospital of China Medical University, Shenyang (China)

    2017-06-15

    To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants.

  3. [The Clinical Application of Video Mediastinoscopy and CT in the N Staging of Preoperative Lung Cancer.].

    Science.gov (United States)

    Wang, Zhiheng; Qi, Weibo; Zhu, Yong; Lin, Ruobai

    2009-10-20

    Preoperative lung cancer with mediastinal lymph nodes metastasis can be diagnosed by vedio mediastinoscopy (VM) and CT. This study was to explore the value of VM and CT in the diagnosis of N staging of preoperative lung cancer, and to discuss the difference between the two methods. Forty-eight cases diagnosed of lung cancer by CT or PET-CT were examined by VM. The sensitivity, specificity, validity, positive predictive value and negative predictive value of VM and CT were speculated according to the postoperative pathological reports, and the difference between VM and CT in the diagnosis of lung cancer with mediastinal lymph nodes metastasis was discussed. (1)Under the examination of VM, 31 patients with the negative outcome received the direct operation; 14 patients with N2 received 2 courses of neoadjuvant chemotherapy before operation; 3 patients with N3 received chemotherapy and/or radiotherapy. (2)Forty-one cases with final diagnosis of lung cancer were used as samples to speculate the sensitivity, specificity, validity, positive predictive value and negative predictive value of VM. They were 93.3%, 100%, 97.6%, 100%, 96.3%, which of CT were 66.7%, 53.8%, 58.5%, 45.5%, 73.7% (Chi-square=4.083, P=0.039), the difference between VM and CT was statistically significant. (3)In this group, the complications of VM incidence rate was 2.08% (1/48), and the case was pneumothorax. VM is superior to CT in the diagnosis of N staging of preoperative lung cancer; Due to its safety and effectiveness, VM will be wildly used in the field of thoracic surgery.

  4. The Clinical Application of Video Mediastinoscopy and CT in the N Staging of Preoperative Lung Cancer

    Directory of Open Access Journals (Sweden)

    Zhiheng WANG

    2009-10-01

    Full Text Available Background and objective Preoperative lung cancer with mediastinal lymph nodes metastasis can be diagnosed by vedio mediastinoscopy (VM and CT. This study was to explore the value of VM and CT in the diagnosis of N staging of preoperative lung cancer, and to discuss the difference between the 2 methods. Methods 48 cases diagnosed of lung cancer by CT or PET-CT were examined by VM. The sensitivity, specificity, validity, positive predictive value and negative predictive value of VM and CT were speculated according to the postoperative pathological reports, and the difference between VM and CT in the diagnosis of lung cancer with mediastinal lymph nodes metastasis was discussed. Results ①Under the examination of VM, 31 patients with the negative outcome received the direct operation, 14 patients with N2 received 2 courses of neoadjuvant chemotherapy before operation, 3 patients with N3 received chemotherapy and/or radiotherapy. ②Forty-one cases with final diagnosis of lung cancer were used as samples to speculate the sensitivity, specificity, validity, positive predictive value and negative predictive value of VM. They were 93.3%, 100%, 97.6%, 100%, 96.3%, which of CT were 66.7%, 53.8%, 58.5%, 45.5%, 73.7% (χ2=4.083, P=0.039, the difference between VM and CT was statistically significant. ③In this group, the complications of VM incidence rate is 2.08% (1/48, the case is pneumothorax. Conclusion VM is superior to CT in the diagnosis of N staging of preoperative lung cancer, it is safe and effective, and there will be a wide perspective for VM in thoracic surgery.

  5. Colonic volvulus detected by CT scan in a case with mental retardation and prune belly syndrome

    Directory of Open Access Journals (Sweden)

    Yoichiro Oka

    2011-10-01

    Full Text Available Colonic volvulus is a rare disease in children. Delayed diagnosis of the condition can often be fatal, especially in pediatric patients with mental retardation. We herein present the case of a female pediatric patient with colonic volvulus, prune belly syndrome, and mental retardation. Preoperative CT scans showed the characteristic signs of this disease. The volvulus occurred in the proximal colon of the colostomy. The release of the colonic volvulus and reconstruction of the colostomy were performed without the resection of the ischemic colon. The postoperative clinical course was uneventful.

  6. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    International Nuclear Information System (INIS)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than that

  7. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    Energy Technology Data Exchange (ETDEWEB)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa [Aichi Medical Univ., Nagakute (Japan). School of Medicine

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than

  8. Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data

    International Nuclear Information System (INIS)

    Krappinger, Dietmar; Roth, Tobias; Gschwentner, Martin; Suckert, Armin; Blauth, Michael; Hengg, Clemens; Kralinger, Franz

    2012-01-01

    Osteoporotic fractures of the proximal humerus show an increasing incidence. Osteoporosis not only influences the fracture risk after low-energy trauma, but also affects the mechanical stability of internal fixation. Preoperative assessment of the local bone quality may be useful in the surgical treatment of patients sustaining these injuries. The aim of the present study was to present a method for the preoperative assessment of the local cancellous bone mineral density (BMD) of the proximal humerus using CT data. In the first part of the study, CT scans of 30 patients with unilateral fractures of the proximal humerus after low-energy trauma were used. The local BMD was assessed on the contralateral uninjured side. All 30 patients additionally underwent dual-emission X-ray absorptiometry (DXA) of the lumbar spine, proximal femur, and forearm of the side of the uninjured proximal humerus within 6 weeks after trauma. Three independent trauma surgeons performed measurements on the uninjured proximal humerus twice with a time interval of 4 weeks in order to assess the inter- and intraobserver reliability of the method. In the second part of the study, the local BMD of 507 patients with either proximal humerus fractures or chronic shoulder instability was assessed by a single trauma surgeon. In both parts, the average HU values in standardized ROIs of the humeral head were automatically calculated after correcting for HU values below the water equivalent. A linear calibration equation was computed for the calculation from HU to BMD using a calibration device (EFP). The intra- and interobserver reliability was high (ICC > 0.95). Correlation coefficients between the local BMD of the proximal humerus and other anatomical sites were between 0.35 (lumbar spine) and 0.64 (forearm). We found a high correlation between the local BMD and age. The BMD in the fracture group was significantly lower than in the instability group. These patients were significantly older and more

  9. Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Roth, Tobias; Gschwentner, Martin; Suckert, Armin; Blauth, Michael; Hengg, Clemens; Kralinger, Franz [Innsbruck Medical University, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria)

    2012-03-15

    Osteoporotic fractures of the proximal humerus show an increasing incidence. Osteoporosis not only influences the fracture risk after low-energy trauma, but also affects the mechanical stability of internal fixation. Preoperative assessment of the local bone quality may be useful in the surgical treatment of patients sustaining these injuries. The aim of the present study was to present a method for the preoperative assessment of the local cancellous bone mineral density (BMD) of the proximal humerus using CT data. In the first part of the study, CT scans of 30 patients with unilateral fractures of the proximal humerus after low-energy trauma were used. The local BMD was assessed on the contralateral uninjured side. All 30 patients additionally underwent dual-emission X-ray absorptiometry (DXA) of the lumbar spine, proximal femur, and forearm of the side of the uninjured proximal humerus within 6 weeks after trauma. Three independent trauma surgeons performed measurements on the uninjured proximal humerus twice with a time interval of 4 weeks in order to assess the inter- and intraobserver reliability of the method. In the second part of the study, the local BMD of 507 patients with either proximal humerus fractures or chronic shoulder instability was assessed by a single trauma surgeon. In both parts, the average HU values in standardized ROIs of the humeral head were automatically calculated after correcting for HU values below the water equivalent. A linear calibration equation was computed for the calculation from HU to BMD using a calibration device (EFP). The intra- and interobserver reliability was high (ICC > 0.95). Correlation coefficients between the local BMD of the proximal humerus and other anatomical sites were between 0.35 (lumbar spine) and 0.64 (forearm). We found a high correlation between the local BMD and age. The BMD in the fracture group was significantly lower than in the instability group. These patients were significantly older and more

  10. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  11. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  12. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  13. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    International Nuclear Information System (INIS)

    Han, Man Seok; Kim, Tae Hyung; Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol; Cho, Jae Hwan

    2012-01-01

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  14. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Seok; Kim, Tae Hyung [Dept. of Radiological Science, Kangwon National University, Chuncheon (Korea, Republic of); Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol [Dept. of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of); Cho, Jae Hwan [Dept. of Radiological Science, Gyeongsan University College, Daegu (Korea, Republic of)

    2012-03-15

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  15. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  16. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  17. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  18. CT scanning in two cases of lipoma of the spinal cord

    NARCIS (Netherlands)

    Dossetor, R.S.; Kaiser, M.; Veiga-Pires, J.A.

    1979-01-01

    Two cases of lipoma of the spinal cord are presented. CT gives a specific diagnosis in this condition without any contrast being given. It is important to make a preoperative diagnosis, as in lipoma of the spinal cord biopsy is dangerous and frequently makes the patient worse. CT is also valuable as

  19. Preoperative CT staging of colon carcinoma (excluding the recto-sigmoid region)

    International Nuclear Information System (INIS)

    Acunas, B.; Rozanes, I.; Acunas, G.; Sayi, I.; Gokmen, E.; Celik, L.

    1990-01-01

    28 Patients with colon carcinoma (excluding the recto-sigmoid region) underwent preoperative staging with computed tomography (CT). The CT had a sensitivity of 60 and 67 per cent for detection of extramural invasion, 75 per cent sensitivity and specificity for lymph node metastases and a sensitivity of 87 per cent and specificity of 95 per cent for liver metastases. Compared with the modified Dukes classification, CT correctly staged 50 per cent of the patients with Dukes A lesions; 40 per cent with Dukes B, 75 per cent with Dukes C and 85 per cent with Dukes D lesions. The data presented in this study showed that CT has limitations in the sensitivity and accuracy of staging local colonic carcinoma. However, the authors recommend its use for patients who are clinically suspected of having extensive disease. (author). 10 refs.; 4 figs.; 2 tabs

  20. A clinical study of major stroke cases of a low-perfusion pattern on a dynamic CT scan

    International Nuclear Information System (INIS)

    Shimada, Tsutomu; Kaneko, Mitsuo; Tanaka, Keisei; Sugiura, Masashi

    1986-01-01

    Preoperative dynamic CT scans have been done for the past 4 years in order to estimate the degree of ischemia in the region responsible. The hemodynamic patterns on the dynamic CT scans were consequently classified into three particular types: Type 1: The collateral flow was preserved considerably, and the peak value of the time-density curve exceeded 50 % of the opposite healthy side. Type 2: The residual flow was moderate, and the peak value was approximately from one-third to one-half of the normal side. Type 3: The residual flow was minimal, and the time-density curve was almost flat or the peak value did not reach even approximately one-third of the opposite side. In general, major stroke cases with a Type 1 pattern on the dynamic CT scan showed a considerably good recovery if the revascularization was completed within 6 hours after the attack. However, cases of the Type 3 pattern often developed into a massive cerebral infarction associated with a marked mid-line shift, and sometimes they were fulminent even after acute revascularization. In this paper, clinical results of 11 major stroke cases with the Type 2 pattern on dynamic CT scans were evaluated. All of them showed hemiplegia, with or without aphasia, just after the onset of the stroke, and dynamic CT scans were performed within 24 hours. The site of the occluded vessel was in the internal carotid artery (ICA) in 4 cases and in the middle cerebral artery (MCA) in 6; severe stenosis in ICA and MCA was found in only one case. The functional recovery was rather poor. Only one was capable of self-care at home; four others required partial care at home, and the other six were bed-ridden. In the 4 surgical cases of acute revascularization, the clinical symptoms did not improve, and the functional recovery was almost equivalent to the natural course. (J.P.N.)

  1. Serial CT scannings in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Fukushima, Masashi; Sawada, Tohru; Kuriyama, Yoshihiro; Kinugawa, Hidekazu; Yamaguchi, Takenori

    1981-01-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemipare sis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis. (author)

  2. Prognosis on follow-up CT of chronic subdural hematomas treated by burr hole evacuation

    International Nuclear Information System (INIS)

    Higeta, Toshiaki; Yamada, Hiroshi; Itoh, Hakuji

    1986-01-01

    A consecutive series of 47 adult patients with chronic subdural hematoma was studied in respect to postoperative follow-up CT after burr hole evacuation. In 15 of our patients, the CT scan was normalized within 60 days. Six patients required reoperation because of reaccumulation or of poor re-expansion, and in 13 patients the follow-up CT showed a persisting subdural fluid collection even after 60 postoperative days. Further studying the correlation between the prognosis on follow-up CT and various factors, such as patient's age, preoperative neurological condition and CT findings or others, authors found that the elderly, especially older than 70 years, had a poor prognosis, and that the prognosis was correlated to the density and the thickness of hematoma on preoperative CT scan. (author)

  3. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  4. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  5. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  6. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  7. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  8. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  9. Dual scan CT image recovery from truncated projections

    Science.gov (United States)

    Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat

    2017-12-01

    There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.

  10. Delayed intracerebral hemorrhage as demonstrated by CT scanning

    International Nuclear Information System (INIS)

    Brunetti, J.; Zingesser, L.; Dunn, J.; Rovit, R.L.; Saint Vincent's Hospital and Medical Center, New York

    1979-01-01

    Three patients are presented who developed delayed intracerebral hematomas after head injury. Two patients had essentially negative CT scans on admission and developed intracerebral hematomas within 24 h after injury. They required surgical treatment and had fatal outcomes. The third patient presented with an epidural hematoma on CT scan, developed an intracerebral hematoma 48 h after evacuation of the epidural hematoma, and did well with conservative management. (orig.) [de

  11. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Liu, Q; Qiu, J; Zhuo, W [Institute of Radiation Medicine Fudan University, Shanghai (China); Majer, M; Knezevic, Z; Miljanic, S [Radiation Chemistry and Dosimetry Laboratory, Ruder Boskovic Institute, Zagreb (Croatia); Hrsak, H [Clinical Hospital Centre Zagreb, Zagreb (Croatia)

    2016-06-15

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

  12. Importance of repeated CT scan in Fournier gangrene treatment: clinical case

    International Nuclear Information System (INIS)

    Ignatenco, Sergiu

    2011-01-01

    A patient of 53 years presented fever, swelling and erythema in the perineal region. After computed tomography (CT) was diagnosed Fournier gangrene. After aggressive surgical debridement postoperative evolution was unfavorable. Repeated CT scan trace spread of infection to new areas that led to new surgical debridement on time. Use of CT scan in the postoperative period allows assessment of the effectiveness of surgical debridement and spread of infection. This article presents CT scan images and the most important periods of intraoperative surgical intervention. (authors)

  13. Serial CT scannings in herpes simplex encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, M.; Sawada, T.; Kuriyama, Y.; Kinugawa, H.; Yamaguchi, T. (National Cardivascular Center, Osaka (Japan))

    1981-10-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemiparesis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis.

  14. Colonic volvulus detected by CT scan in a case with mental retardation and prune belly syndrome.

    Science.gov (United States)

    Oka, Yoichiro; Masumoto, Kouji; Nakamura, Masatoshi; Iwasaki, Akinori

    2011-10-01

    Colonic volvulus is a rare disease in children. Delayed diagnosis of the condition can often be fatal, especially in pediatric patients with mental retardation. We herein present the case of a female pediatric patient with colonic volvulus, prune belly syndrome, and mental retardation. Preoperative CT scans showed the characteristic signs of this disease. The volvulus occurred in the proximal colon of the colostomy. The release of the colonic volvulus and reconstruction of the colostomy were performed without the resection of the ischemic colon. The postoperative clinical course was uneventful. Copyright © 2012. Published by Elsevier B.V.

  15. The Use of SNOMED CT for Representing Concepts Used in Preoperative Guidelines

    NARCIS (Netherlands)

    Ahmadian, Leila; de Keizer, Nicolette F.; Cornet, Ronald

    2009-01-01

    The use of guidelines to improve quality of care depends on presenting them in a standard machine-interpretable form and using common terms in guidelines as well as in patient records. In this study, the use of SNOMED CT for representing concepts used in preoperative assessment guidelines was

  16. Classication Methods for CT-Scanned Carcass Midsections

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    Computed tomography (CT) has successfully been applied in medical environments for decades. In recent years CT has also made its entry to the industrial environments, including the slaughterhouses. In this paper we investigate classication methods for an online CT system, in order to assist...... in the segmentation of the outer fat layer in the mid- section of CT-scanned pig carcasses. Prior information about the carcass composition can potentially be applied for a fully automated solution, in order to optimize the slaughter line. The methods comprise Markov Random Field and contextual Bayesian classication...

  17. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    Science.gov (United States)

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  18. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); GE Global Research, Niskayuna, NY (United States); Rajiah, Prabhakar [UT Southwestern Medical Center, Dallas, TX (United States); Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Thawani, Rajat; Madabhushi, Anant [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); Jacono, Frank J. [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Louis Stokes Cleveland VA Medical Center, Cleveland, OH (United States)

    2017-10-15

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  19. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Rajiah, Prabhakar; Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip; Thawani, Rajat; Madabhushi, Anant; Jacono, Frank J.

    2017-01-01

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  20. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  1. Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Patel, C.N.; Salahudeen, H.M.; Lansdown, M.; Scarsbrook, A.F.

    2010-01-01

    Aim: To evaluate the accuracy of ultrasound and parathyroid scintigraphy using single photon-emission computed tomography/computed tomography (SPECT/CT) for the preoperative localization of solitary parathyroid adenomas in patients with primary hyperparathyroidism who would be suitable for minimally invasive parathyroid surgery. Materials and methods: Retrospective study of 63 consecutive patients with biochemical evidence of primary hyperparathyroidism referred for preoperative localization of parathyroid adenoma that proceeded to surgery in the same institution. All patients underwent high-resolution ultrasound and Technetium-99m sestamibi scintigraphy with planar and SPECT/CT imaging. The accuracy of preoperative imaging was compared to surgical and histological findings as the reference standard. Results: Fifty-nine patients had solitary parathyroid adenomas, three patients had multiglandular hyperplasia, and one patient had multiple parathyroid adenomas confirmed at surgery and histology. Thirty-five solitary parathyroid adenomas were identified preoperatively with ultrasound (64%) and 53 with SPECT-CT (90%). Concordant ultrasound and SPECT/CT findings were found in 35 cases (59%). An additional three adenomas were found with ultrasound alone and 18 adenomas with SPECT/CT alone. Fifty-one of the 56 adenomas localized using combined ultrasound and SPECT/CT were found at the expected sites during surgery. Combined ultrasound and SPECT/CT has an overall sensitivity of 95% and accuracy of 91% for the preoperative localization of solitary parathyroid adenomas. Conclusions: The combination of ultrasound and SPECT/CT has incremental value in accurately localizing solitary parathyroid adenomas over either technique alone, and allows selection of patients with primary hyperparathyroidism who would be suitable for minimally invasive surgery.

  2. Algorithm-enabled partial-angular-scan configurations for dual-energy CT.

    Science.gov (United States)

    Chen, Buxin; Zhang, Zheng; Xia, Dan; Sidky, Emil Y; Pan, Xiaochuan

    2018-05-01

    We seek to investigate an optimization-based one-step method for image reconstruction that explicitly compensates for nonlinear spectral response (i.e., the beam-hardening effect) in dual-energy CT, to investigate the feasibility of the one-step method for enabling two dual-energy partial-angular-scan configurations, referred to as the short- and half-scan configurations, on standard CT scanners without involving additional hardware, and to investigate the potential of the short- and half-scan configurations in reducing imaging dose and scan time in a single-kVp-switch full-scan configuration in which two full rotations are made for collection of dual-energy data. We use the one-step method to reconstruct images directly from dual-energy data through solving a nonconvex optimization program that specifies the images to be reconstructed in dual-energy CT. Dual-energy full-scan data are generated from numerical phantoms and collected from physical phantoms with the standard single-kVp-switch full-scan configuration, whereas dual-energy short- and half-scan data are extracted from the corresponding full-scan data. Besides visual inspection and profile-plot comparison, the reconstructed images are analyzed also in quantitative studies based upon tasks of linear-attenuation-coefficient and material-concentration estimation and of material differentiation. Following the performance of a computer-simulation study to verify that the one-step method can reconstruct numerically accurately basis and monochromatic images of numerical phantoms, we reconstruct basis and monochromatic images by using the one-step method from real data of physical phantoms collected with the full-, short-, and half-scan configurations. Subjective inspection based upon visualization and profile-plot comparison reveals that monochromatic images, which are used often in practical applications, reconstructed from the full-, short-, and half-scan data are largely visually comparable except for some

  3. Spinal CT scan, 1. Cervical and thoracic spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ. (Japan))

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections.

  4. CT-scanning of ancient Greenlandic Inuit temporal bones

    International Nuclear Information System (INIS)

    Homoe, P.; Videbaek, H.

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.)

  5. CT-scanning of ancient Greenlandic Inuit temporal bones

    Energy Technology Data Exchange (ETDEWEB)

    Homoe, P [Copenhagen Univ. (Denmark). Lab. of Biological Anthropology and Dept. of Otolaryngology, Head and Neck Surgery; Lynnerup, N [Copenhagen Univ., Lab. of Biological Anthropology and Univ. Inst. of Ferensic Medicine, Copenhagen (Denmark); Videbaek, H [Hvidovre Univ. Hospital, Copenhagen (Denmark). Dept. of Radiology

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.).

  6. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  7. Reappraisal of radionuclide liver scans for preoperative gastric cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Makoto; Yonahara, Yoshio; Yamashita, Shoji; Ando, Yutaka; Mohri, Makoto [National Second Hospital of Tokyo (Japan)

    1983-04-01

    Radionuclide liver scans were obtained in 89 preoperative patients with gastric cancer. Eight showed definite defects on liver scans. At laparotomy, 14 patients were found to have liver involvement secondary to gastric cancer. The sensitivity of liver scans to predict liver involvement is 57% (8/14), and the specificity is 100% (75/75). The patients with definite defects on liver scans had a lower rate of palliative resection of the primary tumors (2/8) than the patients with liver involvement and no scan abnormality (4/6). The patients with advanced lesions but without liver involvement had the highest probability of resecting the primary tumors (57/63 : 47 radical, and 10 palliative). Normal serum levels of liver chemistries did not preclude the presence of defects on liver scans. Additional three patients were found to have cirrhosis of the liver solely based on liver scans, which was confirmed at laparotomy. Radionuclide liver scans can predict liver involvement with very few false positives, and may discriminate patients unsuitable for laparotomy even with palliative intent.

  8. The usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region

    International Nuclear Information System (INIS)

    Grzesiakowska, U.; Tacikowska, M.; Krajewski, R.; Starosciak, S.; Smorczewska, M.; Wiszniewska-Rawlik, D.

    2005-01-01

    The aim of the study was to determine the usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region. All the patients were treated surgically. CT and/or MR imaging was done in every patient for preoperative evaluation of soft tissue infiltration, destruction of bone structures, and metastasis of lymph nodes of the head and neck. The results of these imagings were compared with surgical evaluations and microscopic examination of postoperative specimens. Both CT and MR imaging have high accuracy in evaluating soft tissue infiltration. CT imaging is much better than MR in evaluating bony destruction. MR imaging is better in evaluating recurrent tumors, in which CT has very low specificity. MR imaging is the only method for evaluating infiltration of the central nervous system.The authors propose the following diagnostic algorithm: CT imaging for initial evaluation before treatment, MR imaging in suspected cases of infiltration of the central nervous system, and MR imaging in recurrent tumors after surgical and radiation treatment. (author)

  9. Colorectal carcinoma: preoperative staging with water enema spiral CT

    International Nuclear Information System (INIS)

    Guan Sheng; Gao Jianbo; Li Yintai; Chen Xuejun; Yang Xuehua; Yang Xiaopeng; Cheng Jingliang

    2001-01-01

    Objective: To determine the value and limitation of water enema spiral CT (WESCT) in staging of colorectal carcinoma. Methods: Forty-eight patients with histologically proven rectum or colon carcinoma were included in this study. All of them were examined by SCT, and the preoperative staging of TNM and Duke were used based on the findings of SCT. The results of WESCT were compared with those of surgical and pathological examination in all cases. Results: All lesions in the 47 cases were demonstrated clearly by WESCT and the sensitivity was 97.9%; 39 cases of 48 patients were correctly staged with TNM and 42 cases with Duke, the accuracy was 81.3% and 87.5% respectively, which were higher than the overall 50 % accuracy reported by references; (3) The accuracy of WESCT was 89.6% (43/48) in T stage and 81.3% (39/48) in N stage. Three cases in M stage were all diagnosed correctly; Conclusion: WESCT scan is a better method of depicting the colorectal carcinoma. It allows for accurate depiction and staging of colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. It is the best imaging method for staging the colorectal carcinoma . However the value of WESCT for early T staging in colorectal carcinoma and minute metastasis of lymph nodes or liver is limited

  10. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  11. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  12. Serial CT scans and Menkes' kinky hair disease

    International Nuclear Information System (INIS)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-01-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 μ g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died. (author)

  13. CT scan of pituitary adenomas

    International Nuclear Information System (INIS)

    Sakoda, K.; Mukada, K.; Yonezawa, M.; Matsumura, S.; Yoshimoto, H.; Mori, S.; Uozumi, T.

    1981-01-01

    CT scan is an extremely useful, almost harmless means of diagnosing pituitary adenomas. Growth hormone (GH)-secreting adenomas tend to have higher absorption coefficent in plain CT than the nonfunctioning and prolactin (PRL)-secreting adenomas. The absorption coefficent on contrast-enhanced CT does not identify the specific type of adenoma. Ring-like enhancement was observed in five nonfunctioning and four PRL-secreting adenomas with suprasellar extension, while cystic components were observed in four nonfunctioning and four PRL-secreting adenomas. In three of ten cases of PRL-secreting microadenomas, the site corresponding to the adenoma was not enhanced, whereas the normal pituitary was. A correlation exists between the size of PRL-secreting adenoma and the serum PRL level, but not between the size of GH-secreting adenomas and the serum GH level. (orig.)

  14. Target volume delineation in external beam partial breast irradiation: less inter-observer variation with preoperative- compared to postoperative delineation

    NARCIS (Netherlands)

    Leij, F. van der; Elkhuizen, P.H.M.; Janssen, T.M.; Poortmans, P.M.P.; Sangen, M. van der; Scholten, A.N.; Vliet-Vroegindeweij, C. van; Boersma, L.J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of

  15. Sphincter preservation in distal CT2N0 rectal cancer after preoperative chemoradiotherapy

    International Nuclear Information System (INIS)

    Wasserberg, Nir; Kundel, Yulia; Purim, Ofer; Keidar, Andrei; Kashtan, Hanoch; Sadot, Eran; Fenig, Eyal; Brenner, Baruch

    2014-01-01

    Preoperative chemoradiotherapy is usually not indicated for cT2N0 rectal cancer. Abdominoperineal resection is the standard treatment for distal rectal tumors. The aim of the study was to evaluate the actual sphincter-preservation rate in patients with distal cT2N0 rectal cancer given neoadjuvant chemoradiotherapy. Data were retrospectively collected for all patients who were diagnosed with distal cT2N0 rectal cancer at a tertiary medical center in 2000–2008 and received chemoradiotherapy followed by surgery (5–7 weeks later). Thirty-three patients (22 male) of median age 65 years (range, 32–88) were identified. Tumor distance from the anal verge ranged from 0 to 5 cm. R0 resection with sphincter preservation was accomplished in 22 patients (66%), with a 22% pathological complete response rate. Median follow-up time was 62 months (range 7–120). There were no local failures. Crude disease-free and overall survival were 82% and 86%, respectively. Factors associated with sphincter preservation were tumor location (OR = 0.58, p = 0.02, 95% CI = 0.37-0.91) and pathological downstaging (OR = 7.8, p = 0.02, 95% CI = 1.35-45.85). Chemoradiotherapy was well tolerated. High rates of sphincter preservation can be achieved after preoperative chemoradiotherapy for distal cT2N0 rectal cancer, with tolerable toxicity, without compromising oncological outcome

  16. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  17. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  18. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  19. Preoperative staging of lung cancer with combined PET-CT

    DEFF Research Database (Denmark)

    Fischer, Barbara; Lassen, Ulrik; Mortensen, Jann

    2009-01-01

    BACKGROUND: Fast and accurate staging is essential for choosing treatment for non-small-cell lung cancer (NSCLC). The purpose of this randomized study was to evaluate the clinical effect of combined positron-emission tomography and computed tomography (PET-CT) on preoperative staging of NSCLC...... one of the following: a thoracotomy with the finding of pathologically confirmed mediastinal lymph-node involvement (stage IIIA [N2]), stage IIIB or stage IV disease, or a benign lung lesion; an exploratory thoracotomy; or a thoracotomy in a patient who had recurrent disease or death from any cause...

  20. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  1. Dipyridamole-thallium scanning in patients undergoing vascular surgery. Optimizing preoperative evaluation of cardiac risk

    International Nuclear Information System (INIS)

    Eagle, K.A.; Singer, D.E.; Brewster, D.C.; Darling, R.C.; Mulley, A.G.; Boucher, C.A.

    1987-01-01

    Dipyridamole-thallium imaging has been suggested as a method of preoperatively assessing cardiac risk in patients undergoing major surgery. To define more clearly its proper role in preoperative assessment, we prospectively evaluated 111 patients undergoing vascular surgery. In the first set of 61 patients, our data confirmed the value of preoperative dipyridamole-thallium scanning in identifying the patients who suffered postoperative ischemic events. Events occurred in eight of 18 patients with reversible defects on preoperative imaging, compared with no events in 43 patients with no thallium redistribution (confidence interval for the risk difference: 0.624, 0.256). The results also suggested that clinical factors might allow identification of a low-risk subset of patients. To test the hypothesis that patients with no evidence of congestive heart failure, angina, prior myocardial infarction, or diabetes do not require further preoperative testing, we evaluated an additional 50 patients having vascular procedures. None of the 23 without the clinical markers had untoward outcomes, while ten of 27 patients with one or more of these clinical markers suffered postoperative ischemic events (confidence interval for the risk difference: 0.592, 0.148). In the clinical high-risk subset, further risk stratification is achieved with dipyridamole-thallium scanning

  2. Dual purpose QA tool developed for teletherapy unit and CT scan in SNDH

    International Nuclear Information System (INIS)

    Shilvant, D.V.; Tamane, C.J.; Pangam, S.B.; Raees, M.D.; Aynoor, S.K.; Pol, P.S.; Verghese, Aju; Ghorpade, C.J.

    2007-01-01

    To make a simple device used in Teletherapy unit and CT scan for depth data measurement. The accurate depth data is essential and very important factor for precise treatment in SAD isocentric setup calculation. In CT scan based treatment planning, the calculation obtained is from the depth given by the CT scan. The success of treatment depends on the same parameters in treatment unit matched with diagnostic CT scan data. To check the depth parameters in both CT scan and Teletherapy unit we have developed a single QA tool in our hospital. As this tool is precise, handy and easily accessible the results obtained from it assures the quality of Teletherapy unit as well as CT scan depth data. This small device resulted data helps a lot in calculations of complicated SAD setup in Telecobalt and also useful in recent new treatment modalities such as IMRT, micro MLC, etc

  3. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  4. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  5. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  6. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  7. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  8. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  9. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  10. Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2014-06-01

    Full Text Available Background and aims. Cone-beam computed tomography (CBCT is an imaging system which has many advantages over computed tomography (CT. In CT scan, Hounsfield Unit (HU is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value. The aim of the present study was to investigate the relationship between gray scale in CBCT and Hounsfield Unit (HU in CT scan. Materials and methods. In this descriptive study, the head of a sheep was scanned with 3 CBCT and one medical CT scanner. Gray scales and HUs were detected on images. Reconstructed data were analyzed to investigate relationship between CBCT gray scales and HUs. Results. A strong correlation between gray scales of CBCT and HUs of CT scan was determined. Conclusion. Considering the fact that gray scale in CBCT is the criteria in measurement of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  11. Preoperative CT planning of screw length in arthroscopic Latarjet.

    Science.gov (United States)

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2018-01-01

    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  12. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  13. The Beatles, the Nobel Prize, and CT scanning of the chest.

    Science.gov (United States)

    Goodman, Lawrence R

    2010-01-01

    From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.

  14. Peritoneal implants without ascites. Preoperative CT diagnosis in colon carcinoma patients

    International Nuclear Information System (INIS)

    Saida, Yukihisa; Itai, Yuji; Tsunoda, Hiroko; Matsueda, Kiyoshi.

    1994-01-01

    We evaluated the preoperative CT findings in 10 patients with colon carcinoma in whom peritoneal metastases had been surgically confirmed. Seven patients lacked ascites. No CT findings suggestive of peritoneal metastasis were observed in two patients without ascites even by retrospective evaluation. A large mass was observed in the cul-de-sac in another. In the remaining four patients, small peritoneal metastases ranging from 8 to 11 mm in diameter were observed at the omentum in two, along the falciform ligament in one, and at both the omentum and the iliac fossa in one; three of these patients had received no prospective diagnosis of peritoneal metastasis prior to the surgery. In patients with advanced colon carcinoma with suspected serosal invasion, the entire peritoneal cavity should be carefully examined and interpreted using CT in order to detect small peritoneal implants even when ascites is absent. (author)

  15. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  16. Cost-effectiveness of preoperative SPECT/CT combined with lymphoscintigraphy vs. lymphoscintigraphy for sentinel lymph node excision in patients with cutaneous malignant melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoffels, Ingo; Leyh, Julia; Schadendorf, Dirk; Klode, Joachim [University of Duisburg-Essen, Department of Dermatology, Venerology and Allergology, University-Hospital Essen, Essen (Germany); Mueller, Markus [University of Duisburg-Essen, Department of Medical controlling, University-Hospital Essen, Essen (Germany); Geisel, Marie Henrike [University of Duisburg-Essen, Institute for Medical Informatics, Biometry and Epidemiology, University-Hospital Essen, Essen (Germany); Poeppel, Thorsten [University of Duisburg-Essen, Department of Nuclear Medicine, University-Hospital Essen, Essen (Germany)

    2014-09-15

    Malignant melanoma has become a major growing interdisciplinary problem in public health worldwide. Sentinel lymph node excision (SLNE) in conjunction with preoperative SPECT/CT is considered the most sensitive and specific staging test for the detection of micrometastatic melanoma in regional lymph nodes. Among patients with clinically lymph node-negative melanoma, the use of SPECT/CT-aided SLNE compared with SLNE alone has been found to be associated with a higher frequency of metastatic involvement and a higher rate of disease-free survival. The aim of this study was to analyse the cost-effectiveness of SLNE with preoperative SPECT/CT for detecting sentinel lymph nodes versus that of standard SLNE with preoperative lymphoscintigraphy from a single-institution database. Cost-effectiveness analysis of two surgical approaches for SLNE for malignant melanoma at the University Hospital Essen, Skin Cancer Center in Essen, Germany. Between March 2003 and April 2011 464 patients eligible for SLNE were identified. Of these patients, 403 with clinically negative lymph nodes who underwent SLNE with or without preoperative SPECT/CT qualified for subsequent analysis. Between March 2003 and October 2008, 254 patients were operated upon with the standard technique. From November 2008, 149 patients underwent the SPECT/CT technique. Cost analysis showed a mean cost saving of EUR 710.50 when SPECT/CT was added to preoperative imaging. This was achieved by a reduction in operative time (median, Q1;Q3, 40 min, 40;50 min, vs. 45 min, 35;60 min; p = 0.002), hospital stay duration (5 days, 3;8 days, vs. 8 days, 4.5;14.5 days; p < 0.001) and more frequent use of local anaesthesia (90.6 % vs. 70.5 %; p < 0.001). The median cost of SLNE using SPECT/CT was EUR 1,619.7 (Q1;Q3 EUR 1,317.0;2,603.4) and of SLNE without SPECT/CT was EUR 2,330.2 (EUR 1,468.3;4,058.1; p < 0.001), a cost saving of 30.5 %. In patients with cutaneous melanoma, the use of preoperative SPECT/CT-aided SLNE compared

  17. Full-Body CT Scans - What You Need to Know

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Full-Body CT Scans - What You Need to Know Share ... if you are thinking of having a whole-body screening: Whole-body CT screening has not been ...

  18. Relevance of computerized tomography in the preoperative evaluation of patients with vulvar cancer

    DEFF Research Database (Denmark)

    Andersen, Kjeld; Zobbe, Vibeke; Thranov, Ingrid Regitze

    2015-01-01

    University Hospital, Rigshospitalet. The patients underwent a gynecological examination, chest x-ray and a preoperative CT scanning of the chest, abdomen and pelvis. It was registered whether the radiological findings regarding the extent of the tumor, lymph node involvement, incidental findings...

  19. The clinical significance of CT in the preoperative diagnosis of colon and rectal cancer

    International Nuclear Information System (INIS)

    Itano, Satoshi; Fuchimoto, Sadanori; Hamada, Fumihiro; Kimura, Takanobu; Orita, Kunzo

    1986-01-01

    The clinical significance of CT in the preoperative diagnosis of colon and rectal cancer was studied. Thirty four patients were investigated in this series. The diagnostic criteria of the CT examination were previously established in a study of wall invasion (S factor), lymph node metastasis (N factor), liver metastasis (H factor) and peritoneal dissemination (P factor). The CT diagnosis was done prospectively according to these criteria, and the CT diagnosis was compared with the macroscopic and histological diagnosis. The accuracy of the prospective diagnosis as to H, S, N and P factors was 79.4 %, 55.9 %, 41.2 % and 20.6 %, respectively. The diagnostic value of CT seemed to be acceptable as to the H factor, but limited to some extent to the S and N factors. (author)

  20. Evolution of traumatic intracerebral hematoma. Analysis of sequential CT scans since per-acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Nagaseki, Yoshishige; Horikoshi, Satoru [Gunma Univ., Maebashi (Japan). School of Medicine; Tamura, Masaru

    1984-05-01

    To clarify the evolution of traumatic intracerebral hematoma (TICH), initial computerized tomography (CT) scans of 28 TICH cases performed within one hour after head trauma were studied along with their follow-up CT scans. They were classified into the following two groups; per-acute group included seven cases in which TICH was completed on the initial CT scans taken within one hour after head injury and acute group included 21 cases in which the initial CT scans revealed isodensity or high density spot and repeat CT scans disclosed TICH by 48 hours after injury. In the per-acute group, initial CT scans showed a homogeneous, well defined, and high density mass (1.5-6.5 cm in diameter). In sequential CT scans of the three cases, the hematoma did not increase but spontaneously disappeared. Other four cases died early after head trauma. Their initial CT scans revealed a large high density mass (3-6.5 cm in diameter) combined with other extracerebral hemorrhages. In the acute group, initial CT scans demonstrated isodensity or high density spot and sequential CT scans showed mottled appearance of salt and pepper appearance, and after a while showed fusion of small high density areas to become a massive high density area (contusional hematoma) by 48 hours after injury. In six cases of this group, the contusional hematoma was removed within 24 hours after injury and in one case at 3.5 days. In other 14 cases, the hematomas shrank or disappeared spontaneously. From these results, it was considered that evolution of TICH's were classified into the two groups; per-acute group resulting from rupture of vessels and acute group resulting from contusion.

  1. Laparoscopic resection aided by preoperative 3-D CT angiography for rectosigmoid colon cancer associated with a horseshoe kidney: A case report.

    Science.gov (United States)

    Maeda, Yoshiaki; Shinohara, Toshiki; Nagatsu, Akihisa; Futakawa, Noriaki; Hamada, Tomonori

    2014-11-01

    We herein report a case of laparoscopic high anterior resection with D3 lymph node dissection for rectosigmoid colon cancer with a horseshoe kidney. A 65-year-old Japanese man referred to our hospital for rectosigmoid colon cancer was found to have a horseshoe kidney on a CT scan. On 3-D CT angiography, an aberrant renal artery was visualized feeding the renal isthmus that arises from the aorta just below the root of the inferior mesenteric artery (IMA). Laparoscopic anterior rectal resection with D3 lymph node dissection was performed. During the operation, the IMA, left ureter, left gonadal vessels and hypogastric nerve plexus could be seen passing over the horseshoe kidney isthmus. With the aid of preoperative 3-D CT angiography, the root of the IMA was identified on the temporal side of the isthmus and divided safely just above the hypogastric nerve. As a horseshoe kidney is often accompanied by aberrant renal arteries and/or abnormal running of the ureter, 3-D CT angiography is useful for determining the location of these structures and avoiding intraoperative injury. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  2. Target volume delineation in external beam partial breast irradiation: Less inter-observer variation with preoperative- compared to postoperative delineation

    International Nuclear Information System (INIS)

    Leij, Femke van der; Elkhuizen, Paula H.M.; Janssen, Tomas M.; Poortmans, Philip; Sangen, Maurice van der; Scholten, Astrid N.; Vliet-Vroegindeweij, Corine van; Boersma, Liesbeth J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of twenty-four breast cancer patients

  3. Socio-economic variation in CT scanning in Northern England, 1990-2002

    Directory of Open Access Journals (Sweden)

    Pearce Mark S

    2012-01-01

    Full Text Available Abstract Background Socio-economic status is known to influence health throughout life. In childhood, studies have shown increased injury rates in more deprived settings. Socio-economic status may therefore be related to rates of certain medical procedures, such as computed tomography (CT scans. This study aimed to assess socio-economic variation among young people having CT scans in Northern England between 1990 and 2002 inclusive. Methods Electronic data were obtained from Radiology Information Systems of all nine National Health Service hospital Trusts in the region. CT scan data, including sex, date of scan, age at scan, number and type of scans were assessed in relation to quintiles of Townsend deprivation scores, obtained from linkage of postcodes with census data, using χ2 tests and Spearman rank correlations. Results During the study period, 39,676 scans were recorded on 21,089 patients, with 38,007 scans and 19,485 patients (11344 male and 8132 female linkable to Townsend scores. The overall distributions of both scans and patients by quintile of Townsend deprivation scores were significantly different to the distributions of Townsend scores from the census wards included in the study (p Conclusions Social inequalities exist in the numbers of young people undergoing CT scans with those from deprived areas more likely to do so. This may reflect the rates of injuries in these individuals and implies that certain groups within the population may receive higher radiation doses than others due to medical procedures.

  4. Diagnostic yield of preoperative computed tomography imaging and the importance of a clinical decision for lung cancer surgery

    International Nuclear Information System (INIS)

    Sato, Shuichi; Koike, Teruaki; Yamato, Yasushi

    2010-01-01

    This study aimed to evaluate the diagnostic yield of preoperative computed tomography (CT) imaging and the validity of surgical intervention based on the clinical decision to perform surgery for lung cancer or suspected lung cancer. We retrospectively evaluated 1755 patients who had undergone pulmonary resection for lung cancer or suspected lung cancer. CT scans were performed on all patients. Surgical intervention to diagnose and treat was based on a medical staff conference evaluation for the suspected lung cancer patients who were pathologically undiagnosed. We evaluated the relation between resected specimens and preoperative CT imaging in detail. A total of 1289 patients were diagnosed with lung cancer by preoperative pathology examination; another 466 were not pathologically diagnosed preoperatively. Among the 1289 patients preoperatively diagnosed with lung cancer, the diagnoses were confirmed postoperatively in 1282. Among the 466 patients preoperatively undiagnosed, 435 were definitively diagnosed with lung cancer, and there were 383 p-stage I disease patients. There were 38 noncancerous patients who underwent surgery with a diagnosis of confirmed or suspected lung cancer. Among the 1755 patients who underwent surgery, 1717 were pathologically confirmed with lung cancer, and the diagnostic yield of preoperative CT imaging was 97.8%. Among the 466 patients who were preoperatively undiagnosed, 435 were compatible with the predicted findings of lung cancer. Diagnostic yields of preoperative CT imaging based on clinical evaluation are sufficiently reliable. Diagnostic surgical intervention was acceptable when the clinical probability of malignancy was high and the malignancy was pathologically undiagnosed. (author)

  5. Preoperative F-18-FDG PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 whole body scans

    International Nuclear Information System (INIS)

    Byun, Byung Hyun; Urn, Sang Moo; Cheon, Gi Jeong; Choi, Chang Woon; Lee, Byeong Cheol; Lee, Guk Haeng; Lee, Yong Sik; Shim, Youn Sang

    2007-01-01

    We evaluated the diagnostic performance of FDG-PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 scan. All patients had total thyroidectomy and following I-131 ablation therapy. In the follow-up period, FDG-PET showed suspected cervical lymph nodes metastases and neck dissection was performed within 3 months after FDG-PET. It had shown for all patients the negative I-131 scan within 3 months before FDG-PET or negative I-131 scan during the period of cervical lymph nodes metastases suspected on the basis of FDG-PET, CT, or ultrasonography until the latest FDG-PET. Preoperative FDG-PET results were compared with the pathologic findings of lymph nodes specimens of 19 papillary thyroid carcinoma patients. Serum Tg, TSH, and Tg antibody levels at the time of latest I-131 scan were reviewed. The size of lymph node was measured by preoperative CT or ultrasonography. In 45 cervical lymph node groups dissected, 31 lymph node groups revealed metastasis. The sensitivity and specificity of FDG-PET for metastasis were 74.2% (23 of 31) and 50.0% (7 of 14), respectively. Except for patients with elevated Tg antibody levels, all patients showed the elevated serum Tg levels than normal limits at the TSH of =30uIU/ml. 8 lesions without suspected metastatic findings on FDG-PET revealed metastasis (false negative), and none of them exceeded 8mm in size (4 to 8mm, median= 6mm). On the other hand, 23 true positive lesions on FDG-PET were variable in size (6 to 17mm, median=9mm). FDG-PET is suitable for the detection of metastatic cervical lymph nodes in patients with recurrent papillary thyroid carcinoma. However, false positive or false negative should be considered according to the size of lymph node

  6. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  7. The pictures of CT scan of gold pneumonitis

    International Nuclear Information System (INIS)

    Taguchi, Yoshio; Iwata, Takekuni; Kuroda, Yasumasa; Sadato, Norihiro; Tanemoto, Kiichiro; Adachi, Kazuhiko.

    1987-01-01

    We experienced two cases of gold pneumonitis and their interesting findings of CT scan. After the cessation of gold salt, both cases were treated with the corticosteroid, resulting in the disappearance of pulmonary manifestations and clearing of shadows on chest roentgenograms. The findings of CT scan on both cases were very interesting. They were the high density shadows along the bronchovascular bundles, the fluffy figures surroundings these shadows and band like shadows reached to the thoracic wall. We considered that each shadows were pathologically compatible with severe exudative changes of interstitial pneumonitis, shrinkage surroundings them and thickness of interlobular septum. (author)

  8. Accuracy of CT enterography and magnetic resonance enterography imaging to detect lesions preoperatively in patients undergoing surgery for Crohn's disease.

    Science.gov (United States)

    Seastedt, Kenneth P; Trencheva, Koiana; Michelassi, Fabrizio; Alsaleh, Doaa; Milsom, Jeffrey W; Sonoda, Toyooki; Lee, Sang W; Nandakumar, Govind

    2014-12-01

    CT enterography and magnetic resonance enterography have emerged as first-line imaging technologies for the evaluation of the gastrointestinal tract in Crohn's disease. The purpose of this work was to evaluate the accuracy of these imaging modalities to identify Crohn's disease lesions preoperatively. This was a retrospective chart review. The study was conducted at a single institution. Seventy-six patients with Crohn's disease with preoperative CT enterography and/or magnetic resonance enterography were included in the study. The number of stenoses, fistulas, and abscesses on CT enterography and/or magnetic resonance enterography before surgery were compared with operative findings. Forty patients (53%) were women, 46 (60%) underwent surgery for recurrent Crohn's disease, and 46 (57%) had previous abdominal surgery. Thirty-six (47%) had a preoperative CT enterography and 43 (57%) had a preoperative magnetic resonance enterography. CT enterography sensitivity was 75% for stenosis and 50% for fistula. MRE sensitivity was 68% for stenosis and 60% for fistula. The negative predictive values of CT enterography and magnetic resonance enterography for stenosis were very low (54% and 65%) and were 85% and 81% for fistula. CT enterography had 76% accuracy for stenosis and 79% for fistula; magnetic resonance enterography had 78% accuracy for stenosis and 85% for fistula. Both were accurate for abscess. False-negative rates for CT enterography were 50% for fistula and 25% for stenosis. False-negative rates for magnetic resonance enterography were 40% for fistula and 32% for stenosis. Unexpected intraoperative findings led to modification of the planned surgical procedure in 20 patients (26%). This study was limited by its small sample size, its retrospective nature, and that some studies were performed at outside institutions. CT enterography and magnetic resonance enterography in patients with Crohn's disease were accurate for the identification of abscesses but not for

  9. Clinico-statistical study on the patients who were applied preoperative CT imaging for dental implant treatment in Iwate Medical University Hospital

    International Nuclear Information System (INIS)

    Shoji, Satoru; Izumisawa, Mitsuru; Satoh, Hitoshi; Hoshino, Masayuki; Takahashi, Noriaki; Shozushima, Masanori; Nakasato, Tatsuhiko

    2007-01-01

    The diagnosis of jaw bones using X-ray computed tomography (CT) is important to determine placement of dental implants. A Clinico-statistical study were made on 490 cases which applied preoperative dental mutiplannar reconstructing CT (dental MPR) imaging for dental implant treatment in Iwate Medical University Hospital, during a five-year period from 2002 to 2006. The following results were obtained: The 490 cases consisted of 179 males and 311 females. They ranged in age from 16 to 80 years, the average age was 53.6 years old. The largest number of cases were in their 50's and, in most generations, there were more female cases than male. Similar cases have been increasing every year. Most patients were referred from other clinics to our hospital. Of the cases that underwent CT scanning more were mandible than maxilla. Implantation prearranged region revealed a predominance of mandible in anterior teeth, and maxilla in molar teeth. The cases that were using diagnostic surgical stents increased in the first three years, but were constant afterwards. (author)

  10. Automated lung volumetry from routine thoracic CT scans: how reliable is the result?

    Science.gov (United States)

    Haas, Matthias; Hamm, Bernd; Niehues, Stefan M

    2014-05-01

    Today, lung volumes can be easily calculated from chest computed tomography (CT) scans. Modern postprocessing workstations allow automated volume measurement of data sets acquired. However, there are challenges in the use of lung volume as an indicator of pulmonary disease when it is obtained from routine CT. Intra-individual variation and methodologic aspects have to be considered. Our goal was to assess the reliability of volumetric measurements in routine CT lung scans. Forty adult cancer patients whose lungs were unaffected by the disease underwent routine chest CT scans in 3-month intervals, resulting in a total number of 302 chest CT scans. Lung volume was calculated by automatic volumetry software. On average of 7.2 CT scans were successfully evaluable per patient (range 2-15). Intra-individual changes were assessed. In the set of patients investigated, lung volume was approximately normally distributed, with a mean of 5283 cm(3) (standard deviation = 947 cm(3), skewness = -0.34, and curtosis = 0.16). Between different scans in one and the same patient the median intra-individual standard deviation in lung volume was 853 cm(3) (16% of the mean lung volume). Automatic lung segmentation of routine chest CT scans allows a technically stable estimation of lung volume. However, substantial intra-individual variations have to be considered. A median intra-individual deviation of 16% in lung volume between different routine scans was found. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  11. Can lymphovascular invasion be predicted by preoperative multiphasic dynamic CT in patients with advanced gastric cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zelan; Liang, Cuishan; Huang, Xiaomei; Liu, Zaiyi [Southern Medical University, Guangzhou, Guangdong (China); Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Liang, Changhong; Huang, Yanqi [Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); He, Lan [Guangdong General Hospital, Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); South China University of Technology, School of Medicine, Guangzhou, Guangdong (China); Chen, Xin [The Affiliated Guangzhou First People' Hospital, Guangzhou Medical University, Department of Radiology, Guangzhou, Guangdong (China); Xiong, Yabing [Southern Medical University, Guangzhou, Guangdong (China)

    2017-08-15

    To determine whether multiphasic dynamic CT can preoperatively predict lymphovascular invasion (LVI) in advanced gastric cancer (AGC). 278 patients with AGC who underwent preoperative multiphasic dynamic CT were retrospectively recruited. Tumour CT attenuation difference between non-contrast and arterial (Δ{sub AP}), portal (Δ{sub PP}) and delayed phase (Δ{sub DP}), tumour-spleen attenuation difference in the portal phase (Δ{sub T-S}), tumour contrast enhancement ratios (CERs), tumour-to-spleen ratio (TSR) and tumour volumes were obtained. All CT-derived parameters and clinicopathological variables associated with LVI were analysed by univariate analysis, followed by multivariate and receiver operator characteristics (ROC) analysis. Associations between CT predictors for LVI and histopathological characteristics were evaluated by the chi-square test. Δ{sub PP} (OR, 1.056; 95% CI: 1.032-1.080) and Δ{sub T-S} (OR, 1.043; 95% CI: 1.020-1.066) are independent predictors for LVI in AGC. Δ{sub PP}, Δ{sub T-S} and their combination correctly predicted LVI in 74.8% (AUC, 0.775; sensitivity, 88.6%; specificity, 54.1%), 68.7% (AUC, 0.747; sensitivity, 68.3%; specificity, 69.4%) and 71.7% (AUC, 0.800; sensitivity, 67.6%; specificity, 77.8%), respectively. There were significant associations between CT predictors for LVI with tumour histological differentiation and Lauren classification. Multiphasic dynamic CT provides a non-invasive method to predict LVI in AGC through quantitative enhancement measurement. (orig.)

  12. Spontaneous spinal epidural hematoma diagnosed by CT scan

    International Nuclear Information System (INIS)

    Abumiya, Takeo; Isu, Toyohiko; Iwasaki, Yoshinobu; Akino, Minoru; Abe, Hiroshi

    1985-01-01

    A case of spinal epidural hematoma diagnosed by CT scan is reported. A 58-year-old man was admitted on June 18, 1984. He had had a sudden onset of severe low-back pain 7 days before admission and had developed paraparesis and numbness of the lower limbs 4 day before admission. Physical examination revealed weakness in the lower limbs, with the reflexes there decreased. The Babinski reflex and the Chaddock reflex were, however, present on both sides. Sensory disturbances were noted below L 2 . Urinary incontinence was present, too. Metrizamide myelography revealed an epidural mass which was located from the power part of T 11 to the upper part of L 2 . A CT scan revealed a biconvex, relatively high-density mass in the posterior spinal canal. On the day of admission, a laminectomy was performed from T 11 to L 1 , and the epidural hematoma was evacuated. The postoperative course was uneventful. Spinal epidural hematoma is uncommon. A CT scan can be used for an early diagnosis of this lesion. According to the review of the CT findings in 15 reported cases, including our case, CT reveals a smoothly marginated biconvex homogeneous density mass. The density of the hematoma decreases with the time. An acute type (within 3 days) is high-density, while a chronic type has a relatively high or isodensity. The acute type is easily differentiated from other epidural masses, such as a herniated disc, an epidural abscess, and an epidural tumor. On the other hand, the diagnosis of the chronic type is not always easy. (author)

  13. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  14. CT Scanning in Identification of Sheep Cystic Echinococcosis.

    Science.gov (United States)

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei; Bao, Yongxing; Li, Haitao

    2017-01-01

    We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung ( R = 0.770, P < 0.001). CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure.

  15. Importance of preoperative imaging in acetabular revision surgery - a case report.

    Science.gov (United States)

    Schmitz, Hc; Egidy, Cc; Al-Khateeb, H; Cárdenas, G; Gehrke, T; Kendoff, D

    2012-01-01

    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures.In our case, a major bony defect of the acetabulum was a result of the protrusion of an implanted reinforcement ring. A preoperative, contrast-enhanced CT scan showed that the urethra was in close proximity to the hook of the reinforcement ring.The preoperative imaging aided in identifying and understanding the potential complications that could occur intraoperatively. Additionally, it delineated the intact anatomic structures prior to surgery, which could have medico-legal implications.The importance of preoperative imaging and the existing literature is discussed within this case description.

  16. Post-operative abdominal CT scanning in extrahepatic biliary atresia

    Energy Technology Data Exchange (ETDEWEB)

    Day, D L; Mulcahy, P F; Letourneau, J G; Dehner, L P

    1989-07-01

    A retrospective review of the abdominal CT scans of 26 children with extrahepatic biliary atresia was performed, and the results were correlated with available surgical and pathologic data. Associated congenital anomalies or acquired abnormalities were identified in these patients. Congenital anomalies included polysplenia, venous anomalies and bowel stenosis. Acquired abnormalities developed secondary to cirrhosis, portal hypertension, intrahepatic biliary duct dilatation, and hepatic ischemia. Despite frequent episodes of ascending cholangitis in these children, no hepatic abscesses were identified by CT or by pathologic examination. In conclusion, abdominal CT scanning of children with extrahepatic biliary atresia can define congenital and acquired abnormalities and provide important anatomic data for the surgeons before liver transplantation. (orig.).

  17. Clinical target volume for rectal cancer. Preoperative radiotherapy

    International Nuclear Information System (INIS)

    Lorchel, F.; Bossel, J.F.; Baron, M.H.; Goubard, O.; Bartholomot, B.; Mantion, G.; Pelissier, E.P.; Maingon, P.

    2001-01-01

    The total meso-rectal excision allows the marked increase of the local control rate in rectal cancer. Therefore, the meso-rectal space is the usual field for the spread of rectal cancer cells. It could therefore be considered as the clinical target volume in the preoperative plan by the radiation oncologist. We propose to identify the mesorectum on anatomical structures of a treatment-position CT scan. (authors)

  18. Helical CT scan for emergent patients with cerebrovascular diseases

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio

    1995-01-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author)

  19. Helical CT scan for emergent patients with cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio [Fukushima Medical Coll. (Japan)

    1995-08-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author).

  20. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  1. Barium enema and CT volumetry for predicting pathologic response to preoperative chemoradiotherapy in rectal cancer patients.

    Science.gov (United States)

    Murono, Koji; Kawai, Kazushige; Tsuno, Nelson H; Ishihara, Soichiro; Yamaguchi, Hironori; Sunami, Eiji; Kitayama, Joji; Watanabe, Toshiaki

    2014-06-01

    Preoperative chemoradiotherapy has been widely used for the prevention of local recurrence of locally advanced rectal cancer, and the effect of chemoradiotherapy is known to be associated with overall survival. We aimed to evaluate the association of the pathologic response grade with tumor recurrence rate after chemoradiotherapy, using radiographic analysis and the Response Evaluation Criteria in Solid Tumors as the parameters. This study was conducted at a single tertiary care institution in Japan. This was a retrospective cohort study of patients undergoing preoperative chemoradiotherapy. A total of 101 low rectal cancer patients receiving preoperative chemoradiotherapy from July 2004 to August 2012 were enrolled. The tumor reduction rate was measured with the use of traditional Response Evaluation Criteria in Solid Tumors, barium enema, and CT volumetry, and the correlation between the reduction rate and the pathologic response grade was examined. The tumor reduction rate assessed according to Response Evaluation Criteria in Solid Tumors showed no association with the pathologic response grade (p =0.61). In contrast, the radiographic response rate by both barium enema and CT volumetry strongly correlated with the pathologic response grade (p volumetry had a lower recurrence rate (p =0.03, p =0.03, p =0.0002, and p =0.001). The difference between high responders and low responders was especially prominent by barium enema and CT volumetry. The study is limited by its retrospective nature. Double-contrast barium enema and CT volumetry were superior to Response Evaluation Criteria in Solid Tumors in evaluating the effect of chemoradiotherapy and predicting the likelihood of tumor recurrence.

  2. Chronologic changes of free fat graft in rabbit using CT

    International Nuclear Information System (INIS)

    Kondo, Norihiro; Kurita, Kenichi; Yajima, Tetsuya; Izumi, Masahiro

    2008-01-01

    Free fat grafts are now used for preventing osteal readhesion, filling dead space, and protecting grafted nerves and vessels. However, it is reported that grafted fat tissue is unstable resulting in high risk of cicatrization and infection. We grafted free fat to a rabbit's back and observed the chronologic change using CT. Ten adult male Japanese white rabbits (3.5 kg) were used. In five rabbits, fat tissue was obtained from the back under general anaesthesia, and transplanted into the back about 50 mm posterior from the donor site. CT was taken in the fixed scan condition five times (preoperation, immediate postoperation, postoperative 1-month, 2-month, and 3-month). In the remaining five rabbits, only CT scan was taken three times as a control. It was observed that we compared preoperative fat volume with the postoperative volume using RealINTAGE. Grafted fat tissue decreased postoperatively at 1-month and completely disappeared at 3-months. We were able to prove that CT scan is effective to observe the chronologic change of grafted fat tissue. Techniques of tissue engineering are necessary for survival of grafted fat tissue. (author)

  3. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  4. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  5. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  6. Colon distension and scan protocol for CT-colonography: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Thierry N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Haan, Margriet C. de, E-mail: m.c.dehaan@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Venema, Henk W., E-mail: h.w.venema@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Stoker, Jaap, E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands)

    2013-08-15

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension, automatic carbon dioxide insufflation should be performed, preferably via a thin, flexible catheter. Hyoscine butylbromide is – when available – the preferred spasmolytic agent because of the positive effect on insufflation and pain/burden and its low costs. Scans in two positions are required for adequate distension and high polyp sensitivity and decubitus position may be used as an alternative for patients unable to lie in prone position. The great intrinsic contrast between air or tagging and polyps allows the use of low radiation dose. Low-dose protocol without intravenous contrast should be used when extracolonic findings are deemed unimportant. In patients suspected for colorectal cancer, normal abdominal CT scan protocols and intravenous contrast should be used in supine position for the evaluation of extracolonic findings. Dose reduction can be obtained by lowering the tube current and/or voltage. Tube current modulation reduces the radiation dose (except in obese patients), and should be used when available. Iterative reconstructions is a promising dose reducing tool and dual-energy CT is currently evaluated for its applications in CT-colonography. This review also provides our institution's insufflation procedure and scan parameters.

  7. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  8. Detection and preoperative staging of carcinoma of the cervix: Comparison between MR imaging and CT

    International Nuclear Information System (INIS)

    Mayr, B.; Schmidt, H.; Baieri, P.; Scheidel, P.; Meier, W.; Schramm, T.

    1986-01-01

    Twenty-four patients with carcinoma of the cervix were examined preoperatively by MR imaging and CT. In all patients histopathologic confirmation was available for specimens obtained either by radical hysterectomy or at staging laparotomy. MR imaging was equivalent to contrast CT in the detection and evaluation of tumor extension in the cervix. Tumor extension to the parametria and pelvic wall was difficult to evaluate on both modalities, as neither had a higher accuracy than pelvic examination conducted under anesthesia. Nodal staging was nearly equivalent on MR imaging and CT. In the detection and staging of carcinoma of the cervix, MR imaged proved to be as good as CT with contrast agent enhancement

  9. Hydro-dynamic CT preoperative staging of gastric cancer: correlation with pathological findings. A prospective study of 107 cases

    International Nuclear Information System (INIS)

    D'Elia, F.; Zingarelli, A.; Grani, M.; Palli, D.

    2000-01-01

    The aim of this study was to evaluate the accuracy of dynamic CT in the preoperative staging of gastric cancer. One hundred seven patients affected by gastric cancer diagnosed by endoscopic biopsy were prospectively staged by dynamic CT prior to tumor resection. After an oral intake of 400-600 ml of tap water and an intravenous infusion of a hypotonic agent, 200 ml of non-ionic contrast agent were administered by power injector using a biphasic technique. The CT findings were prospectively analyzed and correlated with the pathological findings at surgery. The accuracy of dynamic CT for tumor detection was 80 and 99 % in early and advanced gastric cancer, respectively, with overall detection rate of 96 % (103 of 107). Three early (pT1) and one advanced (pT2) cancers were undetected. Tumor stage as determined by dynamic CT agreed with pathological findings in 83 of 107 patients with an overall accuracy of 78 %. The accuracy of CT in detecting increasing degrees of depth of tumor invasion when compared with pathological TNM staging was 20 % (3 of 15) and 87 % (80 of 92) in early and advanced cancer, respectively. The sensitivity, specificity, and accuracy of CT in the preoperative staging (pT3-pT4 vs pT1-pT2) was 93, 90, and 91.6 %, respectively. The sensitivity, specificity, and accuracy of CT in assessing metastasis to regional lymph nodes was 97.2, 65.7, and 87 %, respectively. Computed tomography correctly staged liver metastases in 105 of 107 patients with an overall sensitivity of 87.5 % and specificity of 99 %. The sensitivity of peritoneal involvement was 30 % when ascites or peritoneal nodules were absent. Our findings show that dynamic CT can play a role in the preoperative definition of gastric cancer stage. The results can be used to optimize the therapeutic strategy for each individual patient prior to surgery, thus avoiding unnecessary intervention and allowing careful planning of extended surgery in eligible patients. (orig.)

  10. Estimating local noise power spectrum from a few FBP-reconstructed CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Rongping, E-mail: rongping.zeng@fda.hhs.gov; Gavrielides, Marios A.; Petrick, Nicholas; Sahiner, Berkman; Li, Qin; Myers, Kyle J. [Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland 20993 (United States)

    2016-01-15

    Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has the same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available

  11. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  12. CT scan of bacterial and aseptic meningitis

    International Nuclear Information System (INIS)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role. (author)

  13. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  14. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  15. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  16. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  17. CT study of pancreatic diseases with modified dynamic scanning

    International Nuclear Information System (INIS)

    Qian Minghui; Zhu Guangying

    1990-01-01

    Experience of 20 cases modified dynamic CT scanning is presented. With a slight increased X-ray tube burden, it is possible to investigate tumor blood supply and find small pancreatic insulinoma with this method. The capsular sign typical for chronic traumatic pancreatic hematoma on CT is presented

  18. Dental-CT: image quality and absorbed radiation dose of different scan protocols

    International Nuclear Information System (INIS)

    Schorn, C.; Alamo, L.; Funke, M.; Grabbe, E.; Visser, H.; Hermann, K.P.

    1999-01-01

    Purpose: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. Methods: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). Results: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. Conclusions: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT. (orig.) [de

  19. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  20. Developing optimized CT scan protocols: Phantom measurements of image quality

    International Nuclear Information System (INIS)

    Zarb, Francis; Rainford, Louise; McEntee, Mark F.

    2011-01-01

    Purpose: The increasing frequency of computerized tomography (CT) examinations is well documented, leading to concern about potential radiation risks for patients. However, the consequences of not performing the CT examination and missing injuries and disease are potentially serious, impacting upon correct patient management. The ALARA principle of dose optimization must be employed for all justified CT examinations. Dose indicators displayed on the CT console as either CT dose index (CTDI) and/or dose length product (DLP), are used to indicate dose and can quantify improvements achieved through optimization. Key scan parameters contributing to dose have been identified in previous literature and in previous work by our group. The aim of this study was to optimize the scan parameters of mA; kV and pitch, whilst maintaining image quality and reducing dose. This research was conducted using psychophysical image quality measurements on a CT quality assurance (QA) phantom establishing the impact of dose optimization on image quality parameters. Method: Current CT scan parameters for head (posterior fossa and cerebrum), abdomen and chest examinations were collected from 57% of CT suites available nationally in Malta (n = 4). Current scan protocols were used to image a Catphan 600 CT QA phantom whereby image quality was assessed. Each scan parameter: mA; kV and pitch were systematically reduced until the contrast resolution (CR), spatial resolution (SR) and noise were significantly lowered. The Catphan 600 images, produced by the range of protocols, were evaluated by 2 expert observers assessing CR, SR and noise. The protocol considered as the optimization threshold was just above the setting that resulted in a significant reduction in CR and noise but not affecting SR at the 95% confidence interval. Results: The limit of optimization threshold was determined for each CT suite. Employing optimized parameters, CTDI and DLP were both significantly reduced (p ≤ 0.001) by

  1. Torsion of the greater omentum: A rare preoperative diagnosis

    International Nuclear Information System (INIS)

    Tandon, Ankit Anil; Lim, Kian Soon

    2010-01-01

    Torsion of the greater omentum is a rare acute abdominal condition that is seldom diagnosed preoperatively. We report the characteristic computed tomography (CT) scan findings and the clinical implications of this unusual diagnosis in a 41-year-old man, who also had longstanding right inguinal hernia. Awareness of omental torsion as a differential diagnosis in the acute abdomen setting is necessary for correct patient management

  2. Role of computed tomography (CT scan in staging of cervical carcinoma

    Directory of Open Access Journals (Sweden)

    T V Prasad

    2014-01-01

    Full Text Available Background & objectives: Staging of cervical carcinoma is done clinically using International Federation of Obstetrics and Gynecology (FIGO guidelines. It is based on physical examination findings and also includes results of biopsy, endoscopy and conventional radiological tests like chest radiograph, intravenous urography and barium enema. These conventional radiological investigations have largely been replaced by computed tomography (CT and magnetic resonance imaging (MRI at present. FIGO staging system does not consider CT and MRI mandatory; however, use of these modalities are encouraged. This prospective study was conducted to determine the role of CT in staging work up in women diagnosed with cervical carcinoma. Methods: Fifty three women diagnosed with cervical carcinoma were evaluated with contrast enhanced CT scan of abdomen and pelvis. CT scan images were especially evaluated to determine tumour size, invasion of parmetrium, pelvic walls, rectum, urinary bladder and ureters, pelvic or retroperitoneal lymphadenopathy and distant metastases. CT findings were associated with clinical findings and staging, including findings from cystoscopy and sigmoidoscopy. Results: There was a poor agreement between clinical and CT staging of cervical carcinoma. Primary tumour was demonstrated on CT in 36 (70% of 53 patients. CT underestimated the parametrial, vaginal and pelvic wall invasion when compared with physical examination. CT overestimated the urinary bladder and rectal invasion when compared with cysto-sigmoidoscopy, however, CT had 100 per cent negative predictive value (NPV to exclude bladder and rectal involvement. CT detection of lymph node enlargement and lung metastases influenced the management. Interpretation & conclusions: Our findings show that CT scan does not reliably correlate with clinical FIGO staging of cervical cancer. However, it can detect urinary obstruction as well as nodal or distant metastases and thus improves the

  3. A consideration of a measuring point of ventricular dilatation on CT scanning

    International Nuclear Information System (INIS)

    Kuno, Koichi; Miyake, Kazuo

    1980-01-01

    Ventricular dilatation has been judged by pneumo-ventricurography, pneumo-encepharography and carotid angiography (CAG), though all these procedures are very uncomfortable for patients. On the other hand, the CT scan is very easy as a follow-up study of ventricular dilatation for a weak patient. We carried out the CT scan (Hitachi CT-H 250 Scanner, NaI detector) and CAG on 84 cases. The ventricular dilatation was judged by the degree of outstretch of the strio-thalamic vein on an AP view of the phrebogram, classified into 3 types. For all three types classified by the phrebogram, we studied various measuring points of the ventricle on the CT scan. The portions measured on the CT scan were: (1) the frontal cerebro-ventricular index (F-CVI), (2) the bicaudate cerebro-ventricular index (Bicaud-CVI), and (3) the maximum Monro's cerebro-ventricular index (M-CVI), the width of the frontal horn, and the thickness of the ventricular body. The following results were obtained: (1) In measuring the ventricular size on the CT scan, the most interrelated point with the ventricular dilatation is the M-CVI - the ratio of the largest width of the body through the Monro foramen to the width of the brain. In this case, however, the width of the frontal horn and of the body should also be considered. (2) Voltage and electric current changed the EMI-number, but did not alter the measuring value. In this case, the width and the level should be kept constant. (3) The group with the marked ventricular dilatation has a larger value of the CT scan than its value of GAG. (4) The normal value of the M-CVI is 24 +- 3%, moreover, the width of the frontal horn is less than 10 mm, and the thickness of the ventricular body is less than 17 mm. (author)

  4. Preoperative assessment of gastric artery in patients with gastric cancer by CT angiography on 64-slice spiral CT

    International Nuclear Information System (INIS)

    Tang Lei; Zhang Xiaopeng; Sun Yingshi; Cao Kun; Qi Liping; Cui Yong; Wang Ning

    2010-01-01

    Objective: To evaluate the efficacy of different three-dimensional CTA methods on 64-slice sprial CT in the preoperative assessment of gastric arteries and their variations. Methods: Sixty-six consecutive patients with gastric cancer who underwent 64-slice spiral CT examinations preoperatively were retrospectively studied. To get the STS-MIP images, the thickness of slab was adjusted according to the inner diameter of targeted blood vessels and their cross-layer distribution. After four weeks, the AVVR images of all cases was got by the auto-vessel technique. The demonstration rates and origins of the direct and indirect feeding arteries were analyzed on AVVR and STS-MIP. McNemar tests were used to compare the detection rates of gastric feeding arteries by STS-MIP and AVVR. The relationship between CT value and display rate of vessels was analyzed using independent-samples t test. The variations of blood vessels were analyzed. Results: The display rate of indirect feeding arteries were all 100% (66/66) by STS-MIP and AVVR. The display rates of left gastric artery (LGA) and right gastroepiploic artery (RGEA) were 98.5% (65/66), 100.0% (66/66) and 97.0% (64/66), 100.0% (66/66) by STS-MIP and AVVR respectively. The display rates of right artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (PGA) by AVVR were lower than those of STS-MIP with statistical significances [RGA: 68.2% (45/66) vs. 98.5% (65/66), P<0.01; LGEA: 53.0% (35/66) vs. 97.0% (64/66), P<0.01; SGA: 7.6%(5/66) vs. 59.1% (39/66), P<0.01; PGA: 18.2% (12/66) vs. 63.6% (42/66), P<0.01]. The demonstration rates of LGEA, RGEA and SGA increased accompanied with the increasing of CT value in celiac axis (LGEA: 35 cases displayed with mean CT value of (272 ± 44) HU, 31 cases did not display with mean CT value of (229 ± 42) HU, t=4.043, P<0.01; RGEA: 64 cases

  5. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  6. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Sivit, C.J. [Department of Radiology, Rainbow Babies and Children' s Hospital of the University Hospitals of Cleveland and Case Western Reserve School of Medicine, 11100 Euclid Avenue, Cleveland, OH (United States)

    2000-02-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  7. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    International Nuclear Information System (INIS)

    Sivit, C.J.

    2000-01-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  8. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  9. A case of the CT scanning of a suicidal hanging brain

    International Nuclear Information System (INIS)

    Kawamata, Masaharu; Murooka, Hiroshi; Tanabe, Yasuhiko.

    1988-01-01

    A CT scanning of a case of hanging brain is reported. A 63-year-old man, who had been maintained with Aspirin (30 mg every morning) for cerebral infarction, attempted suicide by hanging, but failed. Several hours later, he was admitted because of consciousness disturbance and so was examined by means of CT scanning. Plain CT scanning showed symmetrical multiple intracerebral hemorrhages. Hemorrhages were found in the subcortical region of the bilateral temporal lobes and in the subependymal region near the foramen of Monro or in the choroidal plexus. We speculated that these hemorrhages may be caused by the congestion of the intracranial venous system caused by squeezing both internal jugular veins by hanging. Past angiograms (1981) for cerebral infarction revealed neither AVM nor angioma. (author)

  10. A review of patient dose and optimisation methods in adult and paediatric CT scanning

    International Nuclear Information System (INIS)

    Dougeni, E.; Faulkner, K.; Panayiotakis, G.

    2012-01-01

    Highlights: ► CT scanning frequency has grown with the development of new clinical applications. ► Up to 32-fold dose variation was observed for similar type of procedures. ► Scanning parameters should be optimised for patient size and clinical indication. ► Cancer risks knowledge amongst physicians of certain specialties was poor. ► A significant number of non-indicated CT scans could be eliminated. - Abstract: An increasing number of publications and international reports on computed tomography (CT) have addressed important issues on optimised imaging practice and patient dose. This is partially due to recent technological developments as well as to the striking rise in the number of CT scans being requested. CT imaging has extended its role to newer applications, such as cardiac CT, CT colonography, angiography and urology. The proportion of paediatric patients undergoing CT scans has also increased. The published scientific literature was reviewed to collect information regarding effective dose levels during the most common CT examinations in adults and paediatrics. Large dose variations were observed (up to 32-fold) with some individual sites exceeding the recommended dose reference levels, indicating a large potential to reduce dose. Current estimates on radiation-related cancer risks are alarming. CT doses account for about 70% of collective dose in the UK and are amongst the highest in diagnostic radiology, however the majority of physicians underestimate the risk, demonstrating a decreased level of awareness. Exposure parameters are not always adjusted appropriately to the clinical question or to patient size, especially for children. Dose reduction techniques, such as tube-current modulation, low-tube voltage protocols, prospective echocardiography-triggered coronary angiography and iterative reconstruction algorithms can substantially decrease doses. An overview of optimisation studies is provided. The justification principle is discussed along

  11. CT scans of giant aneurysms in the vertebro-basilar artery

    International Nuclear Information System (INIS)

    Shishido, Toyofumi; Ohsugi, Tamotsu; Motozaki, Takahiko; Sakaki, Saburo; Matsuoka, Kenzo

    1980-01-01

    Clinical course and neurological and neuroradiological findings of giant aneurysms in the vertebro-basilar artery observed in two of our cases were discussed. The first case was a 66-year-old man. He complained of sensory disturbance over his left face and unstable gait for 2 years before admission. Neurological examinations on admission showed hypesthesia in the territory of the second branch of the left fifth cranial nerve, nystagmus, and a left cerebellar sign. No mental deterioration or pyramidal signs were noticed. Retrograde left brachial artery angiograms revealed a giant aneurysm with inferior pointing measuring 30 x 10 mm in diameter arising from the left superior cerebellar artery. Precontrast CT scans demonstrated a round, large, high-density area, cantaining a relatively low-density area within it, in the medioventral portion of the left cerebellum; a part of this high-density area was markedly enhanced in the postcontrast CT scan. No ventricular dilatations were noticed by CT scans. Direct surgery was abandoned due to the size and location of the aneurysm. No neurologically abnormal finding developed after discharge. The second case was a 61-year-old man. He complained of unstable gait for 2 years before admission. Neurological examinations on admission showed bilateral pyramidal sings (more pronounced on the left) and nystagmus. There were no cranial nerve palsy and no sensory disturbances. Precontrast CT scans showed a large, oval, high-density area in the medioventral portion of the right cerebellum, extending to the upper brainstem; a part of this high-density area was markedly enhanced in the postcontrast CT scans. Retrograde left brachial artery angiograms revealed that the fusiform aneurysm in the left vertebral, the basilar artery, and the dilated basilar artery ran 30 mm from the clivus, with a dorsal convex arch. (J.P.N.)

  12. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  13. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takeguchi, Takaya (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan); Tokyo Medical and Dental University, Department of Diagnostic Radiology, Tokyo (Japan)); Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan)), Email: kj-ibkr@qd6.so-net.ne.jp

    2012-02-15

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm +- 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm +- 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  14. X-CT imaging method for large objects using double offset scan mode

    International Nuclear Information System (INIS)

    Fu Jian; Lu Hongnian; Li Bing; Zhang Lei; Sun Jingjing

    2007-01-01

    In X-ray computed tomography (X-CT) inspection, rotate-only scanner is commonly used because this configuration offers the highest imaging speed and best utilization of X-ray dose. But it requires that the imaging region of the scanned object must fit within the X-ray beam. Another configuration, transverse-rotate scanner, has a bigger field of view, but it is much more time consuming. In this paper, a two-dimensional X-CT imaging method for large objects is proposed to overcome the existing disadvantages. The scan principle of this method has been described and the reconstruction algorithm has been deduced. The results of the computer simulation and the experiments show the validity of the new method. Analysis shows that the scan field of view of this method is 1.8 times larger than that of rotate-only X-CT. The scan speed of this method is also much quicker than transverse-rotate X-CT

  15. Comparison of CT and MRI in diagnosis of cerebrospinal leak induced by multiple fractures of skull base

    International Nuclear Information System (INIS)

    Wang, Xuhui; Xu, Minhui; Liang, Hong; Xu, Lunshan

    2011-01-01

    Multiple basilar skull fracture and cerebrospinal leak are common complications of traumatic brain injury, which required a surgical repair. But due to the complexity of basilar skull fracture after severe trauma, preoperatively an exact radiological location is always difficult. Multi-row spiral CT and MRI are currently widely applied in the clinical diagnosis. The present study was performed to compare the accuracy of cisternography by multi-row spiral CT and MRI in the diagnosis of cerebrospinal leak. A total of 23 patients with multiple basilar skull fracture after traumatic brain injury were included. The radiological and surgical data were retrospectively analyzed. 64-row CT (mm/row) scan and three-dimensional reconstruction were performed in 12 patients, while MR plain scan and cisternography were performed in another 11 patients. The location of cerebrospinal leak was diagnosed by 2 experienced physicians majoring neurological radiology. Surgery was performed in all patients. The cerebrospinal leak location was confirmed and repaired during surgery. The result was considered as accurate when cerebrospinal leak was absent after surgery. According to the surgical exploration, the preoperative diagnosis of the active cerebrospinal leak location was accurate in 9 out of 12 patients with CT scan. The location could not be confirmed by CT because of multiple fractures in 2 patients and the missed diagnosis occurred in 1 patient. The preoperative diagnosis was accurate in 10 out of 11 patients with MRI examination. MRI cisternography is more advanced than multi-row CT scan in multiple basilar skull fracture. The combination of the two examinations may increase the diagnostic ratio of active cerebrospinal leak

  16. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  17. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  18. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  19. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  20. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  1. Progression of CT scan findings in Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hisaharu; Hirayama, Yoshito; Sakuragawa, Norio; Arima, Masataka (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan))

    1989-07-01

    Progression of the lesions revealed by CT scan was observed in five girls with Rett syndrome. The most distinct and common finding was progressive dilatation of Sylvian fissures, frontal extracerebral space, interhemispheric fissure, and sulci mainly in frontal lobe. It may indicate progressive lesion in the frontal and the temporal lobes. In addition, dilatation of the anterior horns of the lateral ventricles and the third ventricle was noted in some cases. Brainstem and cerebellum were small at any age with some morphological development as the patients became elder. Neither malformations nor abnormalities in density were found in any case. It is concluded that the main lesion of Rett syndrome on CT scan is progressive and localized in the frontal and the temporal lobes. (author).

  2. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  3. Cushing's syndrome with an apparently normal CT scan

    International Nuclear Information System (INIS)

    Vlahos, L.; Strigaris, K.; Aliferopoulos, D.; Pontifex, G.

    1981-01-01

    A case of Cushing's syndrome is described in which the CT scan was considered as normal. The diagnosis was established with selective venography and blood sampling and was verified surgically. (orig.)

  4. The diagnostic value of PET/CT scanning in patients with cervical cancer

    DEFF Research Database (Denmark)

    Loft, Annika; Berthelsen, Anne Kiil; Roed, Henrik

    2007-01-01

    OBJECTIVE: To investigate the clinical value of PET/CT as a supplement to FIGO staging in patients with cervical cancer stage >or=1B. METHODS: This prospective study included 120 consecutive patients. After staging, a whole-body PET/CT scan was performed and these examinations were divided into two....../CT scanning for newly diagnosed cervical cancer FIGO stage >or=1B has a high sensitivity and specificity, and can be a valuable supplement to the FIGO staging procedure....

  5. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi [Kobe Central Municipal Hospital, Kobe (Japan)

    1983-04-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.''

  6. Analysis the findings of chest radiograph and CT scan in 217 acute thoracic trauma

    International Nuclear Information System (INIS)

    Huang Shaoying

    2005-01-01

    Objective: To evaluate chest radiograph and CT scan in assessing acute thoracic trauma. Methods: Retrospectively analyzed the findings of chest radiograph and CT scan in 217 cases of acute thoracic trauma and positive rate of each modality was compared. Results: The positive rate of rib and clavicle fracture was higher in chest radiograph than these in CT scan. But the positive rate of chest wall hematoma, mediastinum and subcutaneous emphysema, pneumothorax, hydropneumothorax, damage of lung parenchyma and traumatic pulmonary atelectasis was higher in CT scan than those in chest radiograph. Conclusion: The application of the combined imaging modalities improves assessing of acute thoracic trauma, because the imaging manifestation of the lesion is various. (authors)

  7. Ultrafast CT scanning of an oak log for internal defects

    Science.gov (United States)

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  8. [Non-operation management of 12 cases with brain abscess demonstrated by CT scan].

    Science.gov (United States)

    Long, J

    1990-12-01

    This paper reported 12 cases with brain abscess demonstrated by CT scan. Using antibiotic management without surgical intervention, in 10 cases the curative effects were satisfactory. The paper indicated that CT scan was very useful in prompt and correct diagnosis of brain abscess and with sequential CT scan medical therapy was feasible. It is significant in treatment of brain abscess especially for the patients who have a poor general condition, have the brain abscess located in important functional area or have multiple abscesses so that the operation is difficult for them.

  9. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  10. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  11. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  12. Analysis of cranial CT-scan findings in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, F.; Andoh, T.; Une, K.; Takamatsu, T. (Kitakyushu Municipal Sogo-Ryoiku Center (Japan))

    1981-06-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed.

  13. Analysis of cranial CT-scan findings in cerebral palsy

    International Nuclear Information System (INIS)

    Wada, Fumio; Andoh, Tadashi; Une, Koji; Takamatsu, Tsurukichi

    1981-01-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed. (author)

  14. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  15. Study on the brain CT scan of SLE patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S; Narita, M; Katoh, K; Matsunaga, K; Ishigatsubo, Y [Yokohama City Univ. (Japan). Faculty of Medicine

    1982-03-01

    Cranial CT scanning revealed abnormality in 12 of 25 patients with SLE (48%). Ventricular sulcal enlargement was found mostly in younger patients between 16 and 36 years, an average of 25 years. Abnormality in electroencephalogram, principally paroxysmal abnormality, was found in 8 of 13 cases (62%) of normal CT findings. Non-paroxysmal slow-wave abnormality was observed in 9 of 12 abnormal CT cases. Of 13 patients with CNS symptoms, 8 had abnormal CT findings, and 5 had only mental disorder with normal CT findings. In 12 patients without neuropsychiatric involvement, 4 (33%) had abnormal CT findings. The rate of abnormal CT findings was increased in the patients receiving a high dosage of a steroid agent. Five of 6 patients who showed ventricular sulcal enlargement had been given prednisolone in a dosage of 35 mg or more per day.

  16. Significance and problems of the dynamic CT scan for the diagnosis and treatment of cerebral infarctions

    International Nuclear Information System (INIS)

    Morita, Akio; Teraoka, Akira

    1985-01-01

    Dynamic CT scan is a very useful method for the diagnosis of cerebral infarctions and other ischemic disorders. We have used this method for 1) the ultra-early stage diagnosis of major infarctions, 2) the detection of the recanalization and the disruption of the blood-brain barrier, and 3) the detection of latent ischemic lesions. In this report we discussed the clinical cases and the usual use of this dynamic CT scan. We used a GE CT/T8800 scanner for dynamic CT scanning. Manual bolus-contrast-medium injection was done simultaneously with the first scanning, and 6 sequential scannings (scan time: 4.8 s; scan interval: 1.4 s) were done on the same slice level. Especially in major infarctions (e.g., MCA occlusion), OM 40 was the most preferred slice. In cases of ultra-early stage infarctions (i.e., no abnormal lesions in non-enhanced CT), we used this dynamic CT scan immediately after the non-enhanced CT; we could thus obtain information on the ischemic lesions and the ischemic degree. After that we repeated this examination on Days 3, 7, and 14 for the evaluation of the recanalization and blood-brain-barrier disruption. In the cases of TIA and impending or progressing strokes, dynamic CT scan could disclose latent ischemic lesions; in there instances, we treated the patients with intensive to prevent the prognosis from worsening. These benefits and also some problems were discussed. (author)

  17. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won [Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of); Park, Seong Jin [Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of)

    2012-06-15

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  18. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won; Park, Seong Jin

    2012-01-01

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  19. Utility of CT scan for the diagnosis of chest wall tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, A.; Le Breton, C.; Tassart, M.; Korzec, J.; Bigot, J.M.; Carette, M.F. [Department of Radiology, Tenon Hospital, Paris (France)

    1999-10-01

    The objective of this study was to determine the utility of CT scan findings for the diagnosis of chest wall tuberculosis, excluding the spine. We reviewed 15 patients (13 Africans and 2 Indians) with chest wall tuberculosis, retrospectively. The radiologic examination consisted of a plain X-ray and a CT scan of the chest for each patient. The site of disease was the rib in 13 patients or the body of the sternum in 2 patients. One rib was involved in 11 patients, 2 contiguous ribs (one site) in 2 patients, and bilateral disease (two sites) was observed in the remaining patient. The 14 rib sites involved the posterior arc or costovertebral joint in 11 cases, the anterior arc in 2 cases, and the anterior and middle arc in 1 case. The CT scan findings were an abscess (n = 14) or a soft tissue mass (n = 2), osteolytic lesions (n = 13), periosteal reaction (n = 10), and sequestrum (n = 14). Bone sclerosis was observed only in 3 cases of rib involvement. The association of a soft tissue abscess, an osteolytic lesion, and sequestrum, especially in immigrants to France, suggests chest wall tuberculosis on CT scan. (orig.) With 5 figs., 2 tabs., 11 refs.

  20. CT scanning in stroke patients: meeting the challenge in the remote and rural district general hospital.

    Science.gov (United States)

    Todd, A W; Anderson, E M

    2009-05-01

    National audit data allow crude comparison between centres and indicate that most Scottish hospitals fail to meet current guidelines for CT scanning of the brain in stroke patients. This study identifies some of the reasons for delay in performing CT scans in a largely rural population. This audit study assesses the delays from onset of symptoms, time of admission and request received to CT scan in stroke patients for three different in-patient groups as well as those managed in the community. The reasons for delay in CT scanning varied between different patient groups but for one group of in-patients, changes in booking procedure and introduction of a second CT scanner increased the proportion scanned within 48 hours of request from 65% to 96%. Further developments including the introduction of Saturday and Sunday routine CT scanning, radiologist reporting from home and additional CT scanners placed in remote hospitals may be expected to improve these figures further. Target times of three hours from onset of symptoms to scan to allow thrombolysis may however be impossible to meet for all stroke patients in rural areas.

  1. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi (Kobe Central Municipal Hospital, Kobe (Japan))

    1983-04-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.''

  2. Feasibility of F-18-FDG PET/CT scan in abdominopelvic regions

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2008-01-01

    F-18-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/CT scan, which simultaneously provides metabolic function and morphology on the same tomographic section, is being the key imaging modality for diagnosis and treatment strategy of makignancies in various organs. FDG PET/CT scanning of the whole body beneficially allows the assessment of primary tumor and regional lymph nodes, and distant metastases and co-existed benign/other malignant lesions, as ''one stop shopping'' fashion. This technique contributes to the selection of the optimal treatment in individual patients, and also can predict histopathologic response to treatment and postoperative/post chemo-radiation therapeutic prognosis. In this paper, we describe the fundamental knowledge required for accurate interpretation of FDG PET/CT scan, and review the utility of this technique for diagnosis and treatment strategy of makignancies in abdominal and pelvic regions. (author)

  3. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    International Nuclear Information System (INIS)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi

    1983-01-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.'' (author)

  4. Focal hepatic steatosis: ultrasound and CT scan features may mimick carcinoma of the liver

    International Nuclear Information System (INIS)

    Monnin, J.L.; Blanc, F.; Guiry, P.; Bruel, J.M.; Monnin, E.; Ciurana, A.J.

    1988-01-01

    Ultrasound and CT scan features of focal hepatic steatosis (FHS) may closely resemble those of primary or secondary malignant hepatic tumors. Three cases of FHS in chronic alcoholics are reported. In two cases, the area of steatosis was hyperechogenic upon ultrasonography. In all three patients, CT scan demonstrated a hypodense image, with poor enhancement following opacification and no mass effect. Diagnosis of FHS was ascertained upon hepatic biopsy under CT scan guidance in all three patients [fr

  5. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration.

    Science.gov (United States)

    Wolthaus, J W H; Sonke, J J; van Herk, M; Damen, E M F

    2008-09-01

    lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods noise of individual 4D CT scan frames. We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a

  6. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    International Nuclear Information System (INIS)

    Takeguchi, Takaya; Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko

    2012-01-01

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm ± 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm ± 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  7. Quantitative measurement of ventricular dilatation on CT scan

    International Nuclear Information System (INIS)

    Okita, Naoshi; Mochizuki, Hiroshi; Takase, Sadao

    1985-01-01

    Cerebral atrophy might be judged from the ventricular dilatation with some indices, calculated from various ventricular width. But, there is no general agreement on what index is the most reliable. In this paper, we attempted to establish the index, easy to measure and most reliable. Our method is as follow. 1) We carried out the CT scan (EMI 1010) on 89 neurologically intact patients. Scans were parallel to orbito-meatal line (OML), and were 10 mm in thickness. On CT scan films, various width, area of anterior horns and area of bodies of lateral ventricles were measured. Measurement about the anterior horns of lateral ventricles were carried out on image the most clearly showed the foramen of Monro. And measurements about the bodies of lateral ventricles were on image, 20 mm above the image of anterior horn. Correlations of various width and areas were calculated. Then we proposed new indices with high correlations (over 0.9) with ventricular area; Anterior horn CVI (Cerebro-Ventricular Index) and Body CVI. 2) Patients with myotonic dystrophy show cerebral atrophy. We carried out the CT scan (GECT/T 8800) on 17 myotonic dystrophy patients and 30 controls. Between the two groups, age and sex were almost matched. In the two groups, we calculated our new indices as well as various indices which have been reported; Huckman number, Bifrontal CVI, Bicaudal CVI, Anterior horn index, Hirajima's index, and Cella-media index. The data were analyzed statistically. The ventricular dilatation of myotonic dystrophy patients is more definite with Anterior horn CVI, Bicaudal CVI and Body CVI (p<0.01). These indices have higher correlations with the ventricular area (about 0.9). (J.P.N.)

  8. A case of pineal teratoma with intraventricular free fat on CT scan

    International Nuclear Information System (INIS)

    Uede, Teiji; Takaya, Satoru; Shinya, Toshiyuki; Tanabe, Sumiyoshi; Hashi, Kazuo; Sohma, Tsutomu.

    1986-01-01

    Detection of an intraventricular or intratumoral fat-fluid level on the plain craniograms has been known as a characteristic sign indicating the presence of intracranial teratomatous tumors. On CT scans, however, only thirteen cases have been previously reported to be found an intraventricular and/or subarachnoid free fat associated with spontaneous ruptures of these tumors. We reported a case of pineal teratoma with intraventricular free-fat seen on CT scans. A nine-year-old male with precocious puberty was admitted to our hospital complaining a moderate nonpulsatile headache. Neurological examinations were normal without signs of meningeal irritation. The serum and CSF titer of HCG were raised markedly. The laboratory data of the CSF were normal and there were no pathological cells in the CSF. The CT scans revealed a large heterogeneous mass containing multiple areas of negative density in the pineal region. There were negative density droplets in the bilateral frontal horn on the same CT scans indicating a presence of free fats. At surgery, an yellowish oily material was drained from the tumor, but there was no sign of meningitis over the cortical surface of the occipital lobe. An intraventricular free fat on CT scan have been reported in fourteen cases including ours following the first case described by Fawcitt in 1976. Although most of the cases presented headache, only two cases was diagnosed clinically as chemical meningitis. Pathological changes indicating granulomatous meningitis, however, were noted in five cases, all of them presenting seizure attacks. (author)

  9. Colon distension and scan protocol for CT-colonography: an overview

    NARCIS (Netherlands)

    Boellaard, Thierry N.; de Haan, Margriet C.; Venema, Henk W.; Stoker, Jaap

    2013-01-01

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension,

  10. Brain tumors and CT scan in infants and children, (1). The impact on pediatric neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Ohi, S; Velasco, J M [Northwestern Univ., Chicago, IL (USA). Medical School

    1980-10-01

    The dramatic change in the neuroradiological procedures have been noted after CT scan was introduced in the last several years. Remarkable decreasing numbers of angiographic, pneumoencephalographic and other invasive neuroradiologic studies as well as nuclear brain scan were also found in the pediatric neuroradiology. The authors analyzed the total numbers of these studies performed in the last several years in pediatric neurological/neurosurgical practice in the light of the impact of CT scan especially in the diagnostic procedures and treatments of brain tumor in children. Although the number of these procedures decreased up to 49% in plain skull X-ray, 54% in cerebral angiography, 70% in pneumoencephalography/ventriculography and 79% in nuclear brain scan after CT scan was installed in our results, it is extremely important to renew understanding of those characteristics in each special procedures. Cerebral angiography as well as pneumoencephalography may give the surgeon more precise ideas of the anatomical relationship between the lesion and other normal structures, especially in the posterior fossa tumor in which CT scan occassionally demonstrates only a gross finding. A case with false negative result and another case with a complicated anatomical structure in CT scan were presented. The significance of cerebral angiography and other invasive studies in the diagnosis and follow up of brain tumor in CT scan were discussed.

  11. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams

    International Nuclear Information System (INIS)

    Paiva, F.G.

    2017-01-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification

  12. Vascular involvement in pancreatic carcinoma. Pre-operative assessment by multislice CT angiography

    International Nuclear Information System (INIS)

    Ling Huawei; Guan Yongjing; Ding Bei; Lin Xiaozhu; Zhang Huan; Chen Kemin

    2002-01-01

    Objective: To study the value of multislice CT angiography (MSCTA) in the pre-operative assessment of vascular involvement in pancreatic carcinoma. Methods: 33 cases with pathologically proven pancreatic carcinoma underwent MSCTA prior to surgical intervention. The MSCTA findings in each of the 33 patients were evaluated prospectively by four radiologists. Vascular involvement of pancreatic carcinoma was validated at the time of surgery, which was a reference standard for comparison. Correlation was made between MSCTA findings and surgical results. Results: 11 out of 33 cases with pancreatic carcinoma were considered to be resectable by MSCTA with a positive predictive value of 82% in comparison with surgical findings. MSCTA also had high correlation with surgical results in assessing the non-resectability of pancreatic carcinoma (positive predictive value =95%). Conclusion: MSCTA could delineate the vascular involvement of pancreatic carcinoma with high accuracy and provided valuable information in the preoperative assessment of pancreatic carcinoma

  13. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog; Kim, Dae Young; Yu, Pil Mun

    1992-01-01

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern

  14. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Young [Chung Buk National University College of Medicine, Chungju (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern.

  15. Increased inspiratory pressure for reduction of atelectasis in children anesthetized for CT scan

    International Nuclear Information System (INIS)

    Sargent, Michael A.; Jamieson, Douglas H.; McEachern, Anita M.; Blackstock, Derek

    2002-01-01

    Background: Atelectasis is more frequent and more severe in children anesthetized for CT scan than it is in children sedated for CT scan.Objective: To determine the effect of increased inspiratory pressure on atelectasis during chest CT in anesthetized children. Materials and methods: Atelectasis on chest CT was assessed by two observers in three groups of patients. Group A comprised 13 children (26 lungs) anesthetized at inspiratory pressures up to and including 25 cm H 2 O. Group B included 11 children anesthetized at inspiratory pressures ≥30 cm H 2 O. Group C included 8 children under deep sedation. Results: Atelectasis was significantly more severe in group A than in groups B and C. There was no significant difference between groups B and C. Conclusion: An inspiratory pressure of 30 cm H 2 O is recommended for children anesthetized for CT scan of the chest. (orig.)

  16. Preoperative diagnosis of Amyand's hernia by ultrasound and computed tomography

    Directory of Open Access Journals (Sweden)

    Husam Vehbi

    2016-06-01

    Full Text Available Inguinal hernia is the most common seen groin hernias which mostly contain bowel. The incidence of vermiform appendix in an inguinal hernia is seen in 1% of all inguinal hernia. This is known as Amyand's hernia. Appendix within a hernia can be normal or complicated by appendicitis. Most of these cases are not diagnosed preoperatively and managed during surgery. Preoperative diagnosis of these cases is so rare. Very few cases have been reported so far.In our case, we diagnosed an inflamed appendix in a 49 years old female within right inguinal hernia by using ultrasound and confirmed it by CT scan. Keywords: Amyand's hernia, Appendicitis

  17. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    Science.gov (United States)

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  18. Technological features and clinical feasibility of megavoltage CT scanning

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Akanuma, Atsuo; Sakata, Kouichi; Karasawa, Katsuyuki; Terahara, Atsurou; Onogi, Yuzou; Hasezawa, Kenji; Sasaki, Yasuhito

    1992-01-01

    Megavoltage CT scanning using 4-MV and 6-MV radiotherapy beams has been developed and applied to verify errors in patient positioning. A detector system composed of 120 pairs of cadmium tungstate scintillators with photodiodes is mounted to the treatment unit at a distance of 160 cm from the beam source. Image reconstruction is performed with a standard filtered back-projection algorithm. Scanning time and reconstruction time for a slice is approximately 35 s and 60 s respectively. Although spatial resolution is as large as 4 mm, it has sufficient image quality to be applied for treatment planning and verification. The delivered dose with 4 MV and 6 MV is about 1.4 cGy and 2.8 cGy respectively. When a megavoltage CT image is taken in treatment position, the positioning errors are easily detected by comparing it with diagnostic CT sections for treatment planning. Several clinical examples are presented. (orig.)

  19. Relationship of preoperative gastric cancer CT enhancement ratio and perfusion parameters with serum tumor marker levels and proliferation molecule expression in tumor lesions

    Directory of Open Access Journals (Sweden)

    Yong-Hong Wang

    2017-06-01

    Full Text Available Objective: To study the relationship of preoperative gastric cancer CT enhancement ratio and perfusion parameters with serum tumor marker levels and proliferation molecule expression in tumor lesions. Methods: A total of 68 patients with gastric cancer treated in the Second Hospital of Yulin City between May 2012 and May 2016 were chosen as observation group and sub-divided into early and middle gastric cancer group (n=41 and advanced gastric cancer group (n=27 according to the tumor stage; 50 patients diagnosed with benign gastric diseases in our hospital during the same period were selected as benign gastric lesion group. CT enhancement rate and perfusion parameters of three groups of patients were detected by CT scan, serum tumor marker levels were evacuated by enzyme-linked immunosorbent assay (ELISA, and the proliferation gene mRNA expression levels were detected by RTPCR method. Results: CER, AF, BV and CL levels of advanced gastric cancer group were higher than those of early and middle gastric cancer group and benign gastric lesion group; serum CA72-4, CA19-9, CA125 and CEA contents of advanced gastric cancer group were higher than those of early and middle gastric cancer group and benign gastric lesion group; CADM1, miRNA-34a and Cystatin M mRNA expression in tissue of advanced gastric cancer group were lower than those of early and middle gastric cancer group and benign gastric lesion group while Survivin and I2PP2A mRNA expression were higher than those of early and middle gastric cancer group and benign gastric lesion group. The Pearson test showed that the CT enhancement rate and perfusion parameters in patients with gastric cancer are directly correlated with the serum tumor marker levels and the proliferation gene expression in tumor lesions. Conclusion: Preoperative gastric cancer CT enhancement rate and perfusion parameters are directly related to the tumor malignancy, and can be used as a reliable method for the long-term tumor

  20. Estimation of carrying angle based on CT images in preoperative surgical planning for cubitus deformities

    International Nuclear Information System (INIS)

    Park, Shinsuk; Kim, Eugene

    2009-01-01

    Conventionally, the carrying angle of the elbow is measured using simple two-dimensional radiography or goniometry, which has questionable reliability. This study proposes a novel method for estimating carrying angles using computed tomography that can enhance the reliability of the angle measurement. Data of CT scans from 25 elbow joints were processed to build segmented three-dimensional models. The cross-sectional centerlines of the ulna and the humerus were traced from the 3D models, and the angle between 2 vectors formed from the centerlines of the humerus and the ulna was defined as the 'three-dimensional carrying angle.' These angles were compared with those measured by simple radiograph. Two cases of angular deformity were underwent surgery based on this preoperative surgical planning, and the postoperative 3D carrying angles were evaluated using the proposed method. The mean value of the calculated three-dimensional carrying angle was 20.7deg±3.61, while it was 16.3deg±3.21 based on simple radiography without statistical difference. Based on the 3D carrying angle estimations, 2 surgical cases of cubitus deformities were planned by comparison with the normal contra-lateral elbow. Postoperative angle estimations confirmed that the corrected angles were nearly identical to the planned angles for both cases. The results of this study showed that the carrying angle can be accurately estimated using three-dimensional CT and that the proposed method is useful in evaluating deformities of the elbow with high reliability. (author)

  1. Centre for Industrial Application of CT scanning (CIA-CT) – Four years of results 2009-2013

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Andreasen, Jan Lasson; Christensen, Lars Bager

    activities: Centre of Excellence, Dissemination, Collaboration, Research, and Initiation of new activities. The consortium has consisted of nine partners, including three research institutions, two consultancy partners, two large companies, and two small / medium enterprises. The consortium has acted......The innovation consortium project, carried out September 2009 – August 2013, has aimed to help the participating companies and Danish industry with the introduction of CT scanning as measuring technology, carrying out research at international level. The project has operated through five main...... as a centre of excellence for industrial CT scanning, both nationally and internationally. A network with approx. 40 participants has been established, and a total of 22 students have been educated. Dissemination activities have encompassed: a web page www.cia-ct.mek.dtu.dk , 8 newsletters, 4 topical...

  2. Preoperative White Matter Lesions Are Independent Predictors of Long-Term Survival after Internal Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Niku Oksala

    2014-06-01

    Full Text Available Background: Cerebral white matter lesions (WMLs predict long-term survival of conservatively treated acute stroke patients with etiology other than carotid stenosis. In carotid endarterectomy patients, WMLs are associated with severe carotid stenosis and unstable plaques, with the risk of perioperative complications and with increased 30-day perioperative risk of death. However, no data exist on their effect on postoperative long-term survival, a factor important when considering the net benefit from carotid endarterectomy. Whether this effect is independent of classical risk factors and indications for surgery is not known either. We hypothesized that WMLs could be evaluated from preoperative routine computed tomography (CT scans and are predictors of postoperative survival, independent of classical cardiovascular risk factors, indication category and degree of carotid stenosis. Methods: A total of 353 of 481 (73.4% consecutive patients subjected to carotid endarterectomy due to different indications, i.e. asymptomatic stenosis (n = 28, 7.9%, amaurosis fugax (n = 52, 14.7%, transient ischemic attack (n = 135, 38.2% or ischemic stroke (n = 138, 39.1%, from prospective vascular registries during the years 2001-2010 with digital preoperative CT scans, were included in the study. WMLs were rated by a radiologist (Wahlund criteria in a blinded fashion. Internal carotid artery (ICA stenoses were angiographically graded (Results: WML severity could be assessed with a substantial intraobserver agreement (Spearman's rho 0.843, p Conclusions: WMLs in a preoperative CT scan provide a substantially reliable estimate of postoperative long-term survival of carotid endarterectomy patients independent of currently used criteria, i.e. cardiovascular risk factors, indication category and degree of ipsilateral ICA stenosis.

  3. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  4. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

    International Nuclear Information System (INIS)

    Wolthaus, J. W. H.; Sonke, J.-J.; Herk, M. van; Damen, E. M. F.

    2008-01-01

    Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good

  5. CT SCAN EVALUATION OF PULMONARY NODULE

    Directory of Open Access Journals (Sweden)

    A. Ravi Kumar

    2016-06-01

    Full Text Available BACKGROUND Lung carcinomas are quite commonly diagnosed. Thanks to the ever increasing smokers’ population. Majority of the city dwellers are at a higher risk of having this disease when compared to the village counterparts. The stigma through which the person and the family have to undergo before confirming the diagnosis is enormous. So the radiographic methods of diagnosing the malignancies have to improve. Before confirming the diagnosis, the radiologists, the treating physicians should be somewhat confident about the diagnosis so as to prepare the patients and their relatives for the most probable diagnosis before the confirmatory report. The confirmatory procedures include the PET scan and the Histopathology. Both are time consuming procedures and in an economy like ours, finding a PET scanning centre is rather difficult. So the most probable diagnosis has to be thought of using minimal resource. This study puts in a sincere effort to understand and evaluate the pulmonary nodule when identified by a CT scan. This paper is intended to help the practicing radiologists and also make life easy for a practicing physician to identify correctly the lesions and also help the patients to prevent further progression of the disease. METHODS The study was a cross-sectional study. The sample size of the study consisted of thirty patients. CT scan was done in thirty patients who were identified to have lung nodules either by other mode of radiological studies or first time identified in a CT scan itself. The study was conducted in Fathima Institute of Medical Sciences, Kadapa. The study was conducted from 2014 to 2015. RESULT Non-solid nodules were more in number when compared to the solid nodules. All the non-solid nodules were confirmed to be adenomas. Eighty percent of the nodules which were more than 8 mm in size were confirmed to be malignant. One hundred percent of the spiculated border on CT was confirmed to be malignant. In the present study

  6. Dose profile study in head CT scans using a male anthropomorphic phantom

    International Nuclear Information System (INIS)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P.

    2017-01-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  7. Dose profile study in head CT scans using a male anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P., E-mail: amlgphys@gmail.com, E-mail: pridili@gmail.com, E-mail: apratabhz@gmail.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  8. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  9. Interactive lung segmentation in abnormal human and animal chest CT scans

    International Nuclear Information System (INIS)

    Kockelkorn, Thessa T. J. P.; Viergever, Max A.; Schaefer-Prokop, Cornelia M.; Bozovic, Gracijela; Muñoz-Barrutia, Arrate; Rikxoort, Eva M. van; Brown, Matthew S.; Jong, Pim A. de; Ginneken, Bram van

    2014-01-01

    Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in

  10. CT scanning in patients with amputated legs

    International Nuclear Information System (INIS)

    Huebener, K.H.; Ahlemann, L.M.

    1981-01-01

    CT scanning after above-knee amputation and below-knee amputation helps to determine the calcium salt content of the examined bones, and to differentiate changes in the surrounding soft parts. By comaring the sides, it is quite easy to detect osteoporotic changes shortly after amputation which would otherwise remain undetected by X-ray film examination. It is equally easy to verify muscular changes, whereas characteristic changes in density allow to determine the share of vacant fat in muscular atrophy. Initial examinations proved the usefulness of CT diagnosis for early detection of dystrophic osseous and muscular changes and also show the possibilities of early therapy control of dystrophy treatment. (orig.) [de

  11. Accuracy of preoperative diagnosis for primary hyperparathyroidism by CT, US and scintigraphy

    International Nuclear Information System (INIS)

    Imada, Masanobu; Nonaka, Satoshi; Hayashi, Tatsuya; Kunibe, Isamu; Harabuchi, Yasuaki

    2003-01-01

    We determined the usefulness of computed tomography (CT), ultrasonography (US) and Tc-Tl subtraction scintigraphy for preoperative diagnosis in 12 patients with primary hyperparathyroidism, all of which were solitary adenoma. Seven (63.6%) of 11 tumors were detected by CT, 7 (58.3%) of 12 tumors were detected by US, and 7 (63.6%) of 11 tumors were detected by Tc-Tl subtraction scintigraphy. Of 7 tumors with size>10 mm, 6 (85.7%) were detected by CT, 5 (71.4%) were detected by US, and 6 (85.7%) were detected by Tc-Tl subtraction scintigraphy, whereas only 1 (25%) with a diameter of 10 mm was detected by each of CT or Tc-Tl subtraction scintigraphy and 2 (40%) with diameters 10 mm were detected by US. Of 6 tumors situated behind the thyroid gland or intra thyroid gland, 5 (83.3%) were detected by CT and all 6 (100%) were detected by US, Tl-Tc subtraction scintigraphy, which was employed for 5 tumors, detected all 5 (100%). However, in the tumors situated beneath the thyroid gland only 2 (40%) of 5, 1 (16.7%) of 6 and 2 (33.3%) of 6 were detected by CT, US and Tc-Tl subtraction scintigraphy respectively. In 5 tumors without thyroid disease, 4 (80%) of 5 were detected by both CT and US, 3 (75%) of 4 were detected by Tc-Tl subtraction scintigraphy. However, in 7 tumors with thyroid diseases (papillary carcinoma, follicular carcinoma, follicular adenoma, chronic thyroiditis, and adenomatous goiter), 3 (50%) of 6 were detected by CT, 3 (42.9%) of 7 were detected by US and 4 (57.1%) of 7 were detected by Tc-Tl subtraction scintigraphy. Location of tumor was the factor most likely to make appropriate diagnosis difficult for primary hyperparathyroidism by any assessment method. (author)

  12. On the uncertainties in effective dose estimates of adult CT head scans

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan against the risk of radiation-induced cancer. The question arises: What is the uncertainty in these effective dose estimates? This study calculates the uncertainty of effective dose estimates produced by three computer programs (CT-EXPO, CTDosimetry, and ImpactDose) and one method that makes use of dose-length product (DLP) values. Uncertainties were calculated in accordance with an internationally recognized uncertainty analysis guide. For each of the four methods, the smallest and largest overall uncertainties (stated at the 95% confidence interval) were: 20%-31% (CT-EXPO), 15%-28% (CTDosimetry), 20%-36% (ImpactDose), and 22%-32% (DLP), respectively. The overall uncertainties for each method vary due to differences in the uncertainties of factors used in each method. The smallest uncertainties apply when the CT dose index for the scanner has been measured using a calibrated pencil ionization chamber

  13. Significance of CT analysis of regional lymph node metastases in colorectal cancer; Bedeutung der CT fuer die Beurteilung regionaerer Lymphknotenmetastasen bei kolorektalen Karzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Gomille, T.; Christ, F. [Duesseldorf Univ. (Germany). Abt. fuer Radiologie und Nuklearmedizin; Aleksic, M.; Ulrich, B. [Krankenhaus Gerresheim (Germany). Chirurgische Klinik

    1998-12-01

    Purpose: For preoperative staging of colorectal cancer a CT scan is frequently performed. This report examines the sensitivity of CT for regional lymph node metastasis of colorectal cancer using different criteria. Materials and methods: Preoperative CT scans of 153 patients with colorectal cancer were analyzed using different criteria for N1. The results were then compared to the postoperative histological findings. Results: For N1=lymph nodes (LN)>1 cm the sensitivity was 47%. For N1=LN>1 cm or an increased number of LN<1 cm the sensitivity was 71%. In patients with a primary tumor seen on CT, sensitivity rose to 87%. Discussion: Evidence of regional nodal metastatic disease is only relevant for rectal cancer, colon polyps, and for locally excised tumors when considering present surgical concepts for the treatment of colorectal cancer. In these cases CT analysis using the broadened criteria for N1 proposes a valuable argument regarding possible preoperative radiotherapy or an operative revision. (orig.) [Deutsch] Die Sensitivitaet fuer den Nachweis regionaerer Lymphknotenmetastasen kolorektaler Karzinome wurde unter Anwendung verschiedener Kriterien fuer das N1-Stadium an Patienten mit histologisch gesichertem Lymphknotenbefund untersucht. Fuer das Kriterium N1=Lymphknoten (LK)>1 cm betrug die Sensitivitaet 47%. Fuer N1=LK>1 cm/vermehrte Anzahl LK<1 cm war sie 71%, bei erkennbarem Primaertumor sogar 87%. Unter Beruecksichtigung der derzeit geltenden operativen Therapiekonzepte ist der Nachweis von regionaeren Lymphknotenmetastasen nur bei Rektumkarzinom bzw. fuer Kolonpolypen oder fuer lokal exzidierte Karzinome fuer das therapeutische Vorgehen relevant. In diesen Faellen leistet die CT mit den erweiterten Kriterien fuer ein N1-Stadium trotz hoeherer falsch-positiver Raten eine wertvolle Hilfestellung fuer die Entscheidung ueber eine neoadjuvante Bestrahlung oder eine Nachresektion. (orig.)

  14. Aphasia caused by intracerebral hemorrhage; CT-scan findings and prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Kazuhide; Segawa, Hiromu; Shiokawa, Yoshiaki; Hasegawa, Isao; Sano, Keiji (Fuji Brain Institute and Hospital, Shizuoka (Japan))

    1992-10-01

    It is generally accepted that cases of aphasia can be divided into several groups according to verbal fluency, auditory comprehension, and repetition abilities. Although many authors have studied aphasia and its location by means of a CT scan, the primary lesion on a CT scan with regard to the subtypes of aphasia still remains controversial. In this report we present our new CT classification for the syndromes of aphasia and the prognosis. Twenty-one patients with intracerebral hematoma (ICH) were followed up for more than 3 months after onset. ICH was classified according to the mode of the horizontal extension of the hematoma on a CT scan. Four lines were decided as follows: Line (a) is between the anterior horn of the lateral ventricle and the midpoint of the third ventricle; Line (b) is the vertical line to the saggital line which originates from the midpoint of the third ventricle; Line (c) is between the trigone of the lateral ventricle and the midpoint of the third ventricle. The CT classification consisted of 4 types: in Type A, ICH was located anterior to line (a); in Type B, ICH was located between line (a) and line (b); in Type C, ICH was located between line (b) and line (c); Type B+C, was a combination of Type B and Type C. Transcortical motor aphasia belonged to the Type A group. Transcortical sensory aphasia belonged to the Type B and Type B+C groups. Wernicke's and anomic aphasia belonged to the Type C group. Conduction and global aphasia belonged to the Type B+C group. Pure Broca's aphasia could not be observed in this series. Several relationships between the syndromes of aphasia and its CT findings were evident. On the other hand, the syndromes of aphasia and the degree of recovery were not correlated, except for global aphasia. (author).

  15. Aphasia caused by intracerebral hemorrhage; CT-scan findings and prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Kazuhide; Segawa, Hiromu; Shiokawa, Yoshiaki; Hasegawa, Isao; Sano, Keiji [Fuji Brain Institute and Hospital, Shizuoka (Japan)

    1992-10-01

    It is generally accepted that cases of aphasia can be divided into several groups according to verbal fluency, auditory comprehension, and repetition abilities. Although many authors have studied aphasia and its location by means of a CT scan, the primary lesion on a CT scan with regard to the subtypes of aphasia still remains controversial. In this report we present our new CT classification for the syndromes of aphasia and the prognosis. Twenty-one patients with intracerebral hematoma (ICH) were followed up for more than 3 months after onset. ICH was classified according to the mode of the horizontal extension of the hematoma on a CT scan. Four lines were decided as follows: Line (a) is between the anterior horn of the lateral ventricle and the midpoint of the third ventricle; Line (b) is the vertical line to the saggital line which originates from the midpoint of the third ventricle; Line (c) is between the trigone of the lateral ventricle and the midpoint of the third ventricle. The CT classification consisted of 4 types: in Type A, ICH was located anterior to line (a); in Type B, ICH was located between line (a) and line (b); in Type C, ICH was located between line (b) and line (c); Type B+C, was a combination of Type B and Type C. Transcortical motor aphasia belonged to the Type A group. Transcortical sensory aphasia belonged to the Type B and Type B+C groups. Wernicke's and anomic aphasia belonged to the Type C group. Conduction and global aphasia belonged to the Type B+C group. Pure Broca's aphasia could not be observed in this series. Several relationships between the syndromes of aphasia and its CT findings were evident. On the other hand, the syndromes of aphasia and the degree of recovery were not correlated, except for global aphasia. (author).

  16. Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw [Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Liu, Shu-Hsin [Department of Nuclear Medicine, Buddhist Tzu-Chi General Hospital, 970, Hualien, Taiwan and Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Mok, Greta S. P. [Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, 112, Taipei, Taiwan (China)

    2014-09-15

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

  17. TU-F-BRF-03: Effect of Radiation Therapy Planning Scan Registration On the Dose in Lung Cancer Patient CT Scans

    International Nuclear Information System (INIS)

    Cunliffe, A; Contee, C; White, B; Justusson, J; Armato, S; Malik, R; Al-Hallaq, H

    2014-01-01

    Purpose: To characterize the effect of deformable registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60Gy, 2Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pre-therapy (4–75 days) CT scan and a treatment planning scan with an associated dose map calculated in Pinnacle were collected. To establish baseline correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pre-therapy scans were co-registered with planning scans (and associated dose maps) using the Plastimatch demons and Fraunhofer MEVIS deformable registration algorithms. Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from both registration algorithms. The absolute difference in planned dose (|ΔD|) between manually and automatically mapped landmark points was calculated. Using regression modeling, |ΔD| was modeled as a function of the distance between manually and automatically matched points (registration error, E), the dose standard deviation (SD-dose) in the eight-pixel neighborhood, and the registration algorithm used. Results: 52–92 landmark point pairs (median: 82) were identified in each patient's scans. Average |ΔD| across patients was 3.66Gy (range: 1.2–7.2Gy). |ΔD| was significantly reduced by 0.53Gy using Plastimatch demons compared with Fraunhofer MEVIS. |ΔD| increased significantly as a function of E (0.39Gy/mm) and SD-dose (2.23Gy/Gy). Conclusion: An average error of <4Gy in radiation dose was introduced when points were mapped between CT scan pairs using deformable registration. Dose differences following registration were significantly increased when the Fraunhofer MEVIS registration algorithm was used

  18. [Preoperative assessment of renal vascular anatomy for donor nephrectomy: Is CT superior to MRI?].

    Science.gov (United States)

    Arvin-Berod, A; Bricault, I; Terrier, N; Skowron, O; Cadi, P; Boillot, B; Thuillier, C; Cluze, C; Descotes, J-L; Rambeaud, J-J; Long, J-A

    2011-01-01

    computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are both used in the preoperative assessment of vascular anatomy before donor nephrectomy. Our objective was to determine retrospectively and to compare the sensitivity of CTA and MRA imaging in preoperative renal vascularisation in living kidney donors. between 1999 and 2007, 42 kidney donors were assessed in our center: 27 by MRA, 10 by CTA, and five by both techniques. Images were interpreted using multiplanar reconstructions. Results were compared retrospectively with peroperative findings; discordant cases were re-examined by an experienced radiologist. Numbers of vessels detected with imaging methods was compared with numbers actually found at the operating time. MRA showed 35/43 arteries (Se 81.4 %) and 33/34 veins (Se 97.1 %), and CTA showed 18/18 arteries (Se 100 %) and 15/16 veins (Se 93.8 %). The presence of multiple arteries was detected in only one third of cases (3/9) on MRI scans; this difference was statistically significant. The missed arteries were not detected on second examination of the MRI scans with the knowledge of peroperative findings. MRA is less sensitive than CTA for preoperative vascularisation imaging in living renal donors, especially in the detection of multiple renal arteries. 2010 Elsevier Masson SAS. All rights reserved.

  19. Evaluation of normal brain CT scan in Korean

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Suh, J. H.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1981-06-15

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm ({+-} 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm ({+-} 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age.

  20. Evaluation of normal brain CT scan in Koreans

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodiagnostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normartive criteria in Koreans for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5mm( ± 0.3), more wider in male (male; 5.2mm, female; 4.5mm) and increased with age. 3. Mean width of fourth ventricle is 13mm( ± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  1. Evaluation of normal brain CT scan in Korean

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm (± 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm (± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  2. MRI, PET/CT and ultrasound in the preoperative staging of endometrial cancer - A multicenter prospective comparative study

    DEFF Research Database (Denmark)

    Antonsen, Sofie Leisby; Jensen, Lisa Neerup; Loft, Annika

    2012-01-01

    OBJECTIVES: The aim of this prospective multicenter study was to evaluate and compare the diagnostic performance of PET/CT, MRI and transvaginal two-dimensional ultrasound (2DUS) in the preoperative assessment of endometrial cancer (EC). METHODS: 318 consecutive women with EC were included when...

  3. The use of the eyes protection for dose reduction in CT scans of skull

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Silva, Teogenes A.; Alonso, Thessa C.

    2013-01-01

    The technique for imaging the brain scans of the skull by computed tomography (CT) scanning is the volume bounded by the foramen magnum and the apex of the skull. The lenses are radiosensitive tissues and CT scans of the head deposited significant doses on them, since they are in the region of incidence of the primary beam of X-rays. Thus, the variation of the dose deposited in the crystalline skull CT scans for diagnostic imaging of the brain was investigated. Cranial scans were performed using the acquisition protocol routine with or without the use of bismuth to shield the eyes. To carry out the scans we used a male anthropomorphic phantom, Alderson Rando model and dosimeters (TLD-100) were used to record the doses. These TLDs were used to record specific doses internally to the phantom in specific organs (crystalline, pituitary, thyroid, spinal cord and breasts). The scans were performed on a GE machine, model 64 Discovery channels. The data obtained allowed to observe the variation of dose in organs. The highest dose was recorded in the lens (26,18 mGy), followed by spinal cord (17,79 mGy). Comparing the doses of the two scans it was significant variation in the crystal. Scan using bismuth shield generated smaller doses in the eyes and in the eyes occurred the higher dose reduction, about 37%. The results may contribute to spread a suitable procedure for the optimization of CT scans of the skull

  4. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal...

  5. Evaluation of abdominal CT in the initial treatment of abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishii, Takashi; Kuwata, Katsuya; Yoneyama, Chihiro; Kitamura, Kazuya; Sasaki, Yoshifumi; Kamachi, Masahiro; Nishiguchi, Hiroyasu.

    1986-01-01

    During the last four years 102 patients with abdominal trauma were examined by CT for preoperative evaluation in our hospital. In 35 patients (34 %), the CT scans revealed no abnormal findings. They were all managed conservatively except for one case of perforated small bowel. In 67 patients (66 %) CT revealed evidences of substantial abdominal or retroperitoneal trauma. In 30 of them CT findings were confirmed by surgery. Hepatic injury is usually easily recognized by CT. CT is also useful for the detection of renal or splenic injuries. The majority of those parenchymatous organ injuries were successfully managed with conservative therapy, despite apparent traumatic lesions revealed by CT. Repeat CT scans is proved to be very useful to follow the changes of these traumatic lesions. In conclusion, application of abdominal CT is extremely useful for the initial decision making in treatment of patients with abdominal trauma and for the follow-up observation of injured lesions. (author)

  6. A new method of CT scanning for the diagnosis of mandibular fractures

    International Nuclear Information System (INIS)

    Tsukagoshi, Taku; Satoh, Kaneshige; Onizuka, Takuya

    1990-01-01

    The condylar neck of the mandible is one of the most common fracture sites in the facial skeleton. Such a fracture is routinely diagnosed by A-P, lateral oblique, and Towne projection roentgenography or orthopantomography. Despite the combination of these films, fracture of the neck of the mandible is still difficult to diagnose definitely. Therefore, a new CT scanning method was developed for diagnosing fractures of the neck of the condylar mandible. The CT axis is projected along the length of the mandible, extending from the condyle to the symphysis. This projection visualizes both the condyle and the mandibular symphysis in the same plane. The patient is placed in a supine position with the head fully extended. The base line, a line extending from the midpoint of the glenoid fossa to the menton, is determined with a lateral facial cephalogram. CT scanning with a 5 mm window is performed in parallel with and 2 cm anterior to and 2 cm posterior to the base line. When CT scanning was performed in a healthy volunteer, the condition of the condyle and the condylar neck of the mandible was clearly shown, and the view extended from the condyle to the symphysis. For automobile accident patients in whom fracture of the neck of the mandible was associated with fracture of the symphysis, two fractures were found in the same plane. A newly developed CT scanning technique is useful in the diagnosis of fractures of the condylar neck of the mandible and in the identification of fractures at other mandibular sites. It also allows scanning of patients in a supine position, which may aid in managing patients with multiple traumas. (N.K.)

  7. Value of CT scanning in radiation therapy treatment planning: a prospective study

    International Nuclear Information System (INIS)

    Goitein, M.; Wittenberg, J.; Mendiondo, M.; Doucette, J.; Friedberg, C.; Ferrucci, J.; Gunderson, L.; Linggood, R.; Shipley, W.U.; Fineberg, H.V.

    1979-01-01

    We report the results of a prospective study in which we assessed the value of computed tomography (CT) scanning in planning radiation therapy for 77 patients. First, conventional studies were performed, treatment fields were designed and simulated and, where appropriate, computer generated treatment plans drawn up. Then a CT scan was performed to delineate the location of the tumor and adjacent uninvolved tissues. The treatment goals and plans were reevaluated and changed when necessary. Forty of the 77 patients (52%) had their treatment changed as a result of the CT scan. Of these, four (5%) had a change of treatment modality. Thirty-two patients (42%) had changes in the radiotherapy technique because of inadequate tumor coverage (in 24 patients (31%) part of the tumor was outside one or more of the fields and in the other 8 patients (10%) the tumor coverage was marginal). Field changes resulting only from considerations of normal tissue coverage were made for 4 of these patients (5%). In total, normal tissue coverage was affected in 36 patients (47%). When the significance of these changes was evaluated, CT scanning was judged to be of major value for 28 of the 77 patients (36%) and of minor value in a further 12 patients

  8. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  9. Four cases with localized brain-stem lesion on CT scan following closed head injury

    International Nuclear Information System (INIS)

    Saeki, Naokatsu; Odaki, Masaru; Oka, Nobuo; Takase, Manabu; Ono, Junichi.

    1981-01-01

    Cases of primary brain-stem injury following closed head injury, verified by a CT scan, have been increasingly reported. However, most of them have other intracranial lesions in addition to the brain stem, resulting in a poor outcome. The CT scan of 200 cases with severe head injury-Araki's classification of types 3 and 4 - were analysed. Four cases out of them had localized brain-stem lesion without any other significant intracranial injury on a CT scan at the acute stage and had a better outcome than had previously been reported. In this analysis, these 4 cases were studied, and the CT findings, prognosis, and pathogenesis of the localized brain-stem injury were discussed. Follow-up CT of three cases, and taken one month or more later, showed diffuse cortical atrophy. This may indicate the presence of diffuse cerebral injury which could not be seen on CT scans at the acute stage. This atrophic change may also be related with the mechanism of posttraumatic conscious impairment and posttraumatic neurological deficits, such as mental symptoms and impairment of the higher cortical function. Shearing injury is a probable pathogenesis for this diffuse cortical injury. On the other hand, one case did not have any cortical atrophy on a follow-up CT scan. Therefore, this is a case with a localized primary brain-stem injury. Coup injury against the brain stem by a tentorial margin in a case with a small tentorial opening is a possible mechanism producing the localized brain-stem injury. (J.P.N.)

  10. Micro-pleural Metastasis Without Effusion: CT and US Findings

    International Nuclear Information System (INIS)

    Na, Hyoung Il; Yoo, Seung Min; Kim, Yang Soo; Lee, Hwa Yeon; Song, In Sup; Shim, Hyung Jin; Kwak, Byung Kook; Shin, Jong Wook

    2004-01-01

    Pleural metastasis from malignancy is commonly combined with effusion. We report the ultrasonographic and CT findings in a rare case of micro-pleural metastasis without effusion. A 34-year-old male patient with lung cancer underwent video-assisted thoracoscopic surgery (VATS), prior to open thoracotomy. VATS revealed multiple metastatic micronodules on the pleura, which were overlooked on the preoperative CT scan. The HRCT images and chest ultrasonograms showed clear evidence of pleural micro-nodules

  11. Micro-pleural Metastasis Without Effusion: CT and US Findings

    Energy Technology Data Exchange (ETDEWEB)

    Na, Hyoung Il; Yoo, Seung Min; Kim, Yang Soo; Lee, Hwa Yeon; Song, In Sup; Shim, Hyung Jin; Kwak, Byung Kook; Shin, Jong Wook [Chung-Ang University College of Medicine, Seoul (Korea, Republic of)

    2004-09-15

    Pleural metastasis from malignancy is commonly combined with effusion. We report the ultrasonographic and CT findings in a rare case of micro-pleural metastasis without effusion. A 34-year-old male patient with lung cancer underwent video-assisted thoracoscopic surgery (VATS), prior to open thoracotomy. VATS revealed multiple metastatic micronodules on the pleura, which were overlooked on the preoperative CT scan. The HRCT images and chest ultrasonograms showed clear evidence of pleural micro-nodules

  12. Clinical features and CT scan findings of supratentorial ependymomas and ependymoblastomas

    International Nuclear Information System (INIS)

    Hanakita, Junya; Handa, Hajime

    1984-01-01

    The clinical courses and CT scan findings of 12 cases of supratentorial ependymoma and ependymoblastoma were reviewed. The age of the patient of ependymoma ranged from 3 years to 34 years, with an average age of 16 years. The follow-up time ranged from 2 months to 9 years and 10 months. All of the six patients are still alive. The age of the patients of ependymoblastoma ranged from 7 months to 34 years, with an average age of 17 years. During the follow-up period from 2 weeks to 6 years and 4 months, four patients died. Supratentorial ependymomas and ependymoblastomas show the following characteristic features of CT scans: 1. Calcification: The incidence of calcification was 50% in ependymoma-group, and 100% in ependymoblastoma-group. 2. Cyst formation, ring-enhancement: The cyst formation was noticed in both groups. In ependymoma-group a smooth ring-enhancement pattern and the strongly enhanced mural nodule-like contour were found, but in ependymoblastoma-group, the cyst wall was enhanced in irregular shape. 3. Perifocal edema and mass effect: Considerable mass effect was noticed in both groups. Perifocal edema was slight in many cases of ependymoma-group, but mostly prominent in ependymoblastoma-group. 4. CT scan findings of recurrent tumor: In ependymoma-group, recurrent tumor showed the same characteristics of CT scan as the initial ones. In ependymoblastoma-group, cystic portion decreased in size and irregular shaped solid portion increased in recurrence. (author)

  13. Cement stress predictions after anatomic total shoulder arthroplasty are correlated with preoperative glenoid bone quality.

    Science.gov (United States)

    Terrier, Alexandre; Obrist, Raphaël; Becce, Fabio; Farron, Alain

    2017-09-01

    We hypothesized that biomechanical parameters typically associated with glenoid implant failure after anatomic total shoulder arthroplasty (aTSA) would be correlated with preoperative glenoid bone quality. We developed an objective automated method to quantify preoperative glenoid bone quality in different volumes of interest (VOIs): cortical bone, subchondral cortical plate, subchondral bone after reaming, subchondral trabecular bone, and successive layers of trabecular bone. Average computed tomography (CT) numbers (in Hounsfield units [HU]) were measured in each VOI from preoperative CT scans. In parallel, we built patient-specific finite element models of simulated aTSAs to predict cement stress, bone-cement interfacial stress, and bone strain around the glenoid implant. CT measurements and finite element predictions were obtained for 20 patients undergoing aTSA for primary glenohumeral osteoarthritis. We tested all linear correlations between preoperative patient characteristics (age, sex, height, weight, glenoid bone quality) and biomechanical predictions (cement stress, bone-cement interfacial stress, bone strain). Average CT numbers gradually decreased from cortical (717 HU) to subchondral and trabecular (362 HU) bone. Peak cement stress (4-10 MPa) was located within the keel hole, above the keel, or behind the glenoid implant backside. Cement stress, bone-cement interfacial stress, and bone strain were strongly negatively correlated with preoperative glenoid bone quality, particularly in VOIs behind the implant backside (subchondral trabecular bone) but also in deeper trabecular VOIs. Our numerical study suggests that preoperative glenoid bone quality is an important parameter to consider in aTSA, which may be associated with aseptic loosening of the glenoid implant. These initial results should now be confronted with clinical and radiologic outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  14. A case of Neuro-Behcet's disease with an interesting CT scan picture

    International Nuclear Information System (INIS)

    Sato, Jinichi; Kamitani, Hiroshi; Masuzawa, Hideaki; Matsui, Takayoshi; Mizobe, Masafumi.

    1981-01-01

    A Case of Neuro-Behcet's disease with an interesting CT scan picture was reported. A 31-year-old man with a known history of Behcet's disease was transferred to the Kantoh-Teishin Hospital upon suspicion of a brain tumor in the basal ganglia. Right hemiparesis and mild dysarthria of three weeks' duration and long-standing bilateral blindness were noted. Computerized tomography (CT) demonstrated an enhanced mass in the basal ganglia and surrounding irregular, low-density area in the white matter of the left frotoparietal lobe. The ventricles were shifted to the right. Left carotid angiography revealed a shift of the anterior cerebral artery to the right and a mild deformity of the Sylvian triangle. No tumor stain or abnormal vessels were seen. After high doses of prednisolone, his condition gradually improved. A CT scan two weeks later revealed a decrease in the low-density area and the mass effect, but an unchanged pathological contrast enhancement in the basal ganglia. The contrast enhancement lasted for two months. The CT scan of Neuro-Behcet's disease was discussed. (author)

  15. CT perfusion scanning of the brain in stroke and beyond

    International Nuclear Information System (INIS)

    Riedel, Christian

    2011-01-01

    CT perfusion scanning (CTP) allows for quantitative analysis of cerebral blood flow (CBF) and cerebral blood volume (CBV). Until recently, it was only possible to study brain perfusion parameters in a small stack of CT-slices close to the skull base. With the introduction of multidetector CT scanners with 64 and more detector rows it has become possible to assess perfusion of the entire brain. An optimal choice of scanning parameters like the new 'shuttle'-technique combined with a well adapted regimen for contrast administration is required to guarantee reliable perfusion measurements while still keeping the X-ray dose absorbed by the patient at a minimum. With these techniques, CTP is not only an important modality in the work-up of patients suffering from acute ischemic stroke but can also be valuable in other emergency situations such as in prolonged epileptic seizures or to monitor patients with subacute subarachnoid hemorrhage. (orig.)

  16. Subperiosteal chondroma. Diagnostic value of CT scan imaging in two cases

    International Nuclear Information System (INIS)

    Lerais, J.M.; Auquier, F.; Baudrillard, J.C.; Durot, J.F.; Laugareil, P.; Wallays, C.; Lefort, G.; Daoud, S.; Gaillard, D.

    1988-01-01

    Results of CT scan exploration are reported in two cases of subperiosteal chondroma, one in a 4 year old child affecting the anterior tibial tuberosity the other in a 9 year old child involving the upper end of humerus. Data from CT scan imaging were undoubtedly superior to those of conventional radiography and appear to be characteristic of this benign cartilaginous tumor, greatly facilitating correlation between clinical, radiological and pathologic findings. The scanner should allow certain situations to be dedramatized and the surgical attitude adapted when the functional prognosis is involved [fr

  17. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  18. SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

    Energy Technology Data Exchange (ETDEWEB)

    Park, M; Rosica, D; Agarwal, V; Di Carli, M; Dorbala, S [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984 pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.

  19. Prediction of recurrence after HCC resection. Faint oily deposits in preoperative Lipiodol-CT of remnant liver tissue

    International Nuclear Information System (INIS)

    Yamamoto, M.; Iimuro, Y.; Mogaki, M.; Kachi, K.; Fujii, H.; Matsumoto, Y.

    1994-01-01

    In trying to clarify the high recurrence rate after removal of small hepatocellular carconoma (HCC), we assessed the postoperative evolution of minute hepatic Lipiodol deposits which had been diagnosed as artifacts on the preoperative Lipiodol-CT. Of 27 patients with solitary HCC less than 5 cm in diameter, 14 had such Lipiodol deposits in the preoperative CT and 9 of them (64%) developed recurrent tumors. On the other hand, 6 of the 13 patients without deposits (46%) suffered recurrence, but in 5 of these 6 patients the HCC was metachronous multicentric. The cumulative survival rate of the non-deposit group was better than that of the deposit group (p<0.1). The present study suggested that, even in patients with small HCC, minute concomitant tumors invisible by conventional imaging techniques may exist at the time of surgery. Some of these lesions without sufficient tumor vasculature showing a hypervascular blush on angiography appear to retain small, vague Lipiodol deposits. (orig.)

  20. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  1. Assessment of pancreatic adenocarcinoma: use of low-dose whole pancreatic CT perfusion and individualized dual-energy CT scanning

    International Nuclear Information System (INIS)

    Li, Hai-ou; Guo, Jun; Li, Xiao; Qi, Yao-dong; Wang, Xi-ming; Xu, Zhuo-dong; Liu, Cheng; Chen, Jiu-hong

    2015-01-01

    The objective of this study was to investigate the value of low-dose whole pancreatic computed tomography (CT) perfusion integrated with individualized dual-energy CT (DECT) scanning in the diagnosis of pancreatic adenocarcinoma. Twenty patients with pancreatic adenocarcinoma underwent pancreatic CT perfusion as well as individualized dual-phase DECT pancreatic scans. Perfusion characteristics of non-tumourous pancreatic parenchyma and pancreatic adenocarcinoma were analysed. Weighted-average 120 kVp images and the optimal monoenergetic images in dual phase were reconstructed and the contrast noise ratio (CNR) of pancreas-to-tumour were compared. There were significant difference on blood flow as well as blood volume between pancreatic adenocarcinoma and the non-tumourous pancreatic parenchyma (P < 0.05), whereas no difference on permeability (P > 0.05). CNRs of pancreas-to-tumour in individualized pancreatic phase were significantly higher than those in venous phase (P < 0.05), and CNRs of optimal monoenergetic images were higher than those on weighted-average 120 kVp images (P < 0.05) in both phase. Total effective radiation dose of CT examination was around 9.32–13.75 mSv. Low-dose whole pancreatic CT perfusion can provide functional information, and the individualized pancreatic phase DECT scan is the optimal method for detecting pancreatic adenocarcinomas. The integration of the two techniques has great value in clinical application.

  2. MRI of patients with cerebral palsy and normal CT scan

    International Nuclear Information System (INIS)

    Bogaert, P. van; Szliwowski, H.B.

    1992-01-01

    Three children with clinical evidence of cerebral palsy (CP) and normal cerebral computed tomography (CT) scans were evaluated by magnetic resonance imaging (MRI) to identify CT-undetectable white matter lesions in the watershed zones of arterial territories. The two patients with spastic diplegia showed bilateral lesions either in the subcortical regions or in the occipital periventricular regions. The patient with congenital hemiplegia exhibited unilateral lesions in the periventricular region. We conclude that MRI is more informative than CT for the evaluation of patients with CP. (orig.)

  3. MRI of patients with cerebral palsy and normal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Bogaert, P. van; Szliwowski, H.B. (Hopital Erasme, Brussels (Belgium). Dept. of Neurology); Baleriaux, D.; Christophe, C. (Hopital Erasme, Brussels (Belgium). Dept. of Radiology (Neuroradiology))

    1992-02-01

    Three children with clinical evidence of cerebral palsy (CP) and normal cerebral computed tomography (CT) scans were evaluated by magnetic resonance imaging (MRI) to identify CT-undetectable white matter lesions in the watershed zones of arterial territories. The two patients with spastic diplegia showed bilateral lesions either in the subcortical regions or in the occipital periventricular regions. The patient with congenital hemiplegia exhibited unilateral lesions in the periventricular region. We conclude that MRI is more informative than CT for the evaluation of patients with CP. (orig.).

  4. Influence of PET/CT-introduction on PET scanning frequency and indications. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Eschmann, S.M.; Krause, B.J.; Roedel, R.; Tiling, R.; Weckesser, M.

    2007-01-01

    Aim: to evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: the study included all examinations performed on stand alone PET- or PET/CT-scanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: the overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: the introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry. (orig.)

  5. Body surface area determined by whole-body CT scanning: need for new formulae?

    DEFF Research Database (Denmark)

    Villa, Chiara; Primeau, Charlotte; Hesse, Ulrik

    2017-01-01

    Calculation of the estimated body surface area (BSA) by body height and weight has been a challenge in the past centuries due to lack of a well-documented gold standard. More recently, available techniques such as 3D laser surface scanning and CT scanning may be expected to quantify the BSA...... Mimics software, and BSA values were automatically extracted from the program. They were compared with nine predictive equations from the literature. Remarkably, close correlations (r > 0·90) were found between BSA values from CT scans and those from the predictive formulae. A mean BSA of the 54 cadavers...... equations, with the CT scan determination as gold standard. It is concluded that DuBois and DuBois' equation can be safely used in normal-weight male subjects with high accuracy, but it seems likely that BSA is underestimated in underweight subjects and overestimated in overweight individuals. Creation...

  6. Prediction of nodal involvement in primary rectal carcinoma without invasion to pelvic structures: accuracy of preoperative CT, MR, and DWIBS assessments relative to histopathologic findings.

    Directory of Open Access Journals (Sweden)

    Jun Zhou

    Full Text Available OBJECTIVE: To investigate the accuracy of preoperative computed tomography (CT, magnetic resonance (MR imaging and diffusion-weighted imaging with background body signal suppression (DWIBS in the prediction of nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. METHODS AND MATERIALS: Fifty-two subjects with primary rectal cancer were preoperatively assessed by CT and MRI at 1.5 T with a phased-array coil. Preoperative lymph node staging with imaging modalities (CT, MRI, and DWIBS were compared with the final histological findings. RESULTS: The accuracy of CT, MRI, and DWIBS were 57.7%, 63.5%, and 40.4%. The accuracy of DWIBS with higher sensitivity and negative predictive value for evaluating primary rectal cancer patients was lower than that of CT and MRI. Nodal staging agreement between imaging and pathology was fairly strong for CT and MRI (Kappa value = 0.331 and 0.348, P<0.01 but was relatively weaker for DWIBS (Kappa value = 0.174, P<0.05. The accuracy was 57.7% and 59.6%, respectively, for CT and MRI when the lymph node border information was used as the criteria, and was 57.7% and 61.5%, respectively, for enhanced CT and MRI when the lymph node enhancement pattern was used as the criteria. CONCLUSION: MRI is more accurate than CT in predicting nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. DWIBS has a great diagnostic value in differentiating small malignant from benign lymph nodes.

  7. Correlations between biochemical testing, anthology findings and preoperative sestamibi scans: a retrospective study of the minimally invasive radioguided parathyroidectomy (MIRP) approach

    International Nuclear Information System (INIS)

    Stawicki, S.; El Chaar, M.; Baillie, D.; Jaik, N.; Estrada, F.

    2007-01-01

    Sestamibi imaging is the most widely used preoperative localization study for patients with hyperparathyroidism. Previous reports examine the relationship between the weight and volume of excised parathyroid glands and preoperative serum calcium and parathyroid hormone (PTH) levels.The aim of this study was to examine whether these variables correlate with the results of preoperative Sestamibi scans. A retrospective review of 150 consecutive patients who underwent preoperative sestamibi imaging for primary hyperparathyroidism between 1998 and 2007 was performed. Variables studied included patient demographics, diagnostic test (sestamibi) results, operative/pathology findings and surgical outcome (normocalcaemia vs. persistent hypercalcaemia). Sestamibi scans were designated as either 'negative' (NSS) or 'positive' (PSS), where PSS correctly localized abnormal gland(s) enabling a focused neck exploration. The results of sestamibi imaging were correlated with calcium/PTH levels, weight/volume of excised glands and patient outcomes and demographics. Total excised gland weight/volume and preoperative serum calcium levels were significantly higher with PSS (all, p ≤ 0.04). Higher preoperative serum calcium levels and greater total gland weight/volume were significantly associated with successful operative outcome (presence of postoperative normocalcaemia; all, p ≤ 0.01). Factors associated with operative failure included multi-gland disease (p <≤ 0.01) and NSS (p ≤0.01). Higher diagnostic PTH levels (≥ 150 pg/mL) were associated with greater excised gland mass (p ≤ 0.05) and volume (p ≤ 0.05). Male gender was associated with higher preoperative serum calcium levels (p < 0.02). Of interest, patients with single-gland disease had significantly higher preoperative PTH levels than patients with multi-gland disease (155 vs. 109 pg/mL, p ≤ 0.05). Positive sestamibi scans are associated with heavier/larger parathyroid glands and higher preoperative serum

  8. Experimental study of abdominal CT scanning exposal doses adjusted on the basis of pediatric abdominal perimeter

    International Nuclear Information System (INIS)

    Wei Wenzhou; Zhu Gongsheng; Zeng Lingyan; Yin Xianglin; Yang Fuwen; Liu Changsheng

    2006-01-01

    Objective: To optimize the abdominal helical CT scanning parameters in pediatric patients and to reduce its radiation hazards. Methods: 60 canines were evenly grouped into 4 groups on the basis of pediatric abdominal perimeter, scanned with 110,150,190 and 240 mAs, and their qualities of canine CT images were analyzed. 120 pediafric patients with clinic suspected abdominal diseases were divided into 4 groups on the basis of abdominal perimeter, scanned by optimal parameters and their image qualities were analyzed. Results: After CT exposure were reduced, the percentages of total A and B were 90.9 % and 92.0 % in experimental canines and in pediatric patients, respectively. Compared with conventional CT scanning, the exposure and single slice CT dose index weighted (CTDIw) were reduced to 45.8%-79.17%. Conclusion: By adjusted the pediatric helical CT parameters basedon the of pediatric abdominal perimeter, exposure of patient to the hazards of radiation is reduced. (authors)

  9. Emergency medicine summary code for reporting CT scan results: implementation and survey results.

    Science.gov (United States)

    Lam, Joanne; Coughlin, Ryan; Buhl, Luce; Herbst, Meghan; Herbst, Timothy; Martillotti, Jared; Coughlin, Bret

    2018-06-01

    The purpose of the study was to assess the emergency department (ED) providers' interest and satisfaction with ED CT result reporting before and after the implementation of a standardized summary code for all CT scan reporting. A summary code was provided at the end of all CTs ordered through the ED from August to October of 2016. A retrospective review was completed on all studies performed during this period. A pre- and post-survey was given to both ED and radiology providers. A total of 3980 CT scans excluding CTAs were ordered with 2240 CTs dedicated to the head and neck, 1685 CTs dedicated to the torso, and 55 CTs dedicated to the extremities. Approximately 74% CT scans were contrast enhanced. Of the 3980 ED CT examination ordered, 69% had a summary code assigned to it. Fifteen percent of the coded CTs had a critical or diagnostic positive result. The introduction of an ED CT summary code did not show a definitive improvement in communication. However, the ED providers are in consensus that radiology reports are crucial their patients' management. There is slightly increased satisfaction with the providers with less than 5 years of experience with the ED CT codes compared to more seasoned providers. The implementation of a user-friendly summary code may allow better analysis of results, practice improvement, and quality measurements in the future.

  10. Gambaran CT Scan Toraks Sesuai dengan Jenis Sitologi/Histologi pada Pasien Kanker Paru yang Merokok

    Directory of Open Access Journals (Sweden)

    Rosa Tatun

    2016-03-01

    Full Text Available Kanker paru merupakan  penyebab kematian paling banyak akibat keganasan. Kanker paru memberikan gambaran CT scan yang berbeda sesuai dengan jenis sitologi/histologinya. Pemeriksaan CT scan  toraksdengan teknik high resolution computed tomography (HRCT dapat memperlihatkan kelainan kanker parusecara rinci. Penelitian dilakukan di Instalasi Radiologi RSU Persahabatan, Jakarta bekerja sama denganDepartemen Pulmonologi dan Respirasi RSU Persahabatan terhadap 100 sampel yang diperoleh pada bulanNovember 2014 hingga Maret 2015. Berdasarkan jenis sitologi/histologi kanker paru (adenokarsinoma dankarsinoma sel skuamosa/KSS tidak ditemukan  variabel yang bermakna secara statistik  (bentuk, letak, tepispikulasi, tepi lobulasi, nodul satelit. Variabel yang paling banyak ditemukan pada adenokarsinoma maupunKSS adalah bentuk massa, lokasi di sentral dan paru sebelah kanan. Gambaran kanker paru adenokarsinomadan KSS pada pasien merokok paling banyak berupa massa, lokasi di sentral dan lobus kanan paru. Kata kunci: kanker paru, merokok, CT scan toraks   Lung Cancer CT Scan Findings in Smoker Patients Basedon Cytology/Histology Abstract Lung cancer is the leading cause of most deaths due to malignancy. Lung cancer CT scan provides an overview according to the type of cytology / histology. Thorax CT scan with high resolution technique (HRCT may revealdetail lung cancer abnormalities. This study was conducted between Department of Radiology and Departmentof Pulmonology Respiratory, Persahabatan Hospital Jakarta based on 100 samples, November 2014 until March2015. Based on cytological/histological type (adenocarcinoma and squamous cell carcinoma/KSS, it was not found significant meaningfull variables (shape, location, spiculate edge, lobulate edge, satellite nodules. Most commonly variables found in adenocarcinomas and KSS were mass forming, central location, right lung location.Most of adenocarcinoma and SCC in smoked patients were mass forming, central

  11. Direct CT scanning of the lesser pelvis - frontal vs sagittal plane

    International Nuclear Information System (INIS)

    Khadzhigeorgiev, G.; Lichev, A.

    1994-01-01

    Whenever axial scanning alone is used, the anatomical patterns of the true pelvis and the organs contained in it, particularly in women, give rise to diagnostic difficulties during CT assessment of neoplasms originating from these organs. The high demands on precision characterization of the pathological changes in the pelvis minor organs necessitate the obtaining of reliable density and size measurement data, not merely from the axial plane, but from the frontal and sagittal ones as well. The deficient information afforded by secondary reconstruction of the pelvis mind images requires an mandatory evaluation of the potentialities of direct frontal and direct sagittal scanning of the pelvis minor using standard CT equipment. Information yielded by images from direct frontal and direct sagittal pelvis minor scanning as well as diagnostic problems where application of this type of scanning is indicated operational difficulties and their overcoming, are among the issues discussed. 8 figs., 7 refs

  12. Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan

    International Nuclear Information System (INIS)

    Wang, Adam S.; Pelc, Norbert J.

    2011-01-01

    Purpose: The choice of CT protocol can greatly impact patient dose and image quality. Since acquiring multiple scans at different techniques on a given patient is undesirable, the ability to predict image quality changes starting from a high quality exam can be quite useful. While existing methods allow one to generate simulated images of lower exposure (mAs) from an acquired CT exam, the authors present and validate a new method called synthetic CT that can generate realistic images of a patient at arbitrary low dose protocols (kVp, mAs, and filtration) for both single and dual energy scans. Methods: The synthetic CT algorithm is derived by carefully ensuring that the expected signal and noise are accurate for the simulated protocol. The method relies on the observation that the material decomposition from a dual energy CT scan allows the transmission of an arbitrary spectrum to be predicted. It requires an initial dual energy scan of the patient to either synthesize raw projections of a single energy scan or synthesize the material decompositions of a dual energy scan. The initial dual energy scan contributes inherent noise to the synthesized projections that must be accounted for before adding more noise to simulate low dose protocols. Therefore, synthetic CT is subject to the constraint that the synthesized data have noise greater than the inherent noise. The authors experimentally validated the synthetic CT algorithm across a range of protocols using a dual energy scan of an acrylic phantom with solutions of different iodine concentrations. An initial 80/140 kVp dual energy scan of the phantom provided the material decomposition necessary to synthesize images at 100 kVp and at 120 kVp, across a range of mAs values. They compared these synthesized single energy scans of the phantom to actual scans at the same protocols. Furthermore, material decompositions of a 100/120 kVp dual energy scan are synthesized by adding correlated noise to the initial material

  13. An assessment of pulmonary emphysema in smokers using CT scan

    International Nuclear Information System (INIS)

    Satoh, Katashi; Kobayashi, Takuya; Misao, Takahiko

    1999-01-01

    We assessed the relationship between PE and smoking in 639 cases (411 males and 228 females with age ranged 21-86 years) who underwent CT scans during the period, from December 1997 to December 1998, under suspicion of respiratory disease on chest radiograph or some respiratory complaints. PE was diagnosed by the existence of low attenuation areas in CT scan and not by pulmonary function tests. CT was performed with 10 mm collimation in a standard algorithm. PE, regardless of the grade, was seen: in 189 out of 348 (54.3%) cases in male smokers and in only 2 out of 63 (3.2%) cases in male non-smokers; and in 5 out of 25 (20.0%) female smokers and in 4 out of 203 (2.0%) female non-smokers. PE was observed in more than half of male smokers. High incidence of PE was also observed in even younger generation, and its severity progresses with advancing age and increasing smoking index. (author)

  14. A New, Simple Method for Estimating Pleural Effusion Size on CT Scans

    Science.gov (United States)

    Moy, Matthew P.; Berko, Netanel S.; Godelman, Alla; Jain, Vineet R.; Haramati, Linda B.

    2013-01-01

    Background: There is no standardized system to grade pleural effusion size on CT scans. A validated, systematic grading system would improve communication of findings and may help determine the need for imaging guidance for thoracentesis. Methods: CT scans of 34 patients demonstrating a wide range of pleural effusion sizes were measured with a volume segmentation tool and reviewed for qualitative and simple quantitative features related to size. A classification rule was developed using the features that best predicted size and distinguished among small, moderate, and large effusions. Inter-reader agreement for effusion size was assessed on the CT scans for three groups of physicians (radiology residents, pulmonologists, and cardiothoracic radiologists) before and after implementation of the classification rule. Results: The CT imaging features found to best classify effusions as small, moderate, or large were anteroposterior (AP) quartile and maximum AP depth measured at the midclavicular line. According to the decision rule, first AP-quartile effusions are small, second AP-quartile effusions are moderate, and third or fourth AP-quartile effusions are large. In borderline cases, AP depth is measured with 3-cm and 10-cm thresholds for the upper limit of small and moderate, respectively. Use of the rule improved interobserver agreement from κ = 0.56 to 0.79 for all physicians, 0.59 to 0.73 for radiology residents, 0.54 to 0.76 for pulmonologists, and 0.74 to 0.85 for cardiothoracic radiologists. Conclusions: A simple, two-step decision rule for sizing pleural effusions on CT scans improves interobserver agreement from moderate to substantial levels. PMID:23632863

  15. Protocol for CT in the position of discomfort: preoperative assessment of femoroacetabular impingement - how we do it and what the surgeon wants to know

    International Nuclear Information System (INIS)

    Grabinski, Rafal; Ou, Daniel; Saunder, Kate; Rotstein, Andrew; Singh, Parminder; Pritchard, Michael; O'Donnell, John

    2014-01-01

    The use of computed tomography of the hip in a position of discomfort (CT-POD) in combination with 2D and 3D surface rendering is a technique increasingly used to aid in the assessment and confirmation of femoral and acetabular bony abnormalities related to femoroacetabular impingement. The purpose of this article is to describe this dynamic method of assessment. Patients referred by orthopaedic surgeons for assessment of femoroacetabular impingement as part of preoperative planning and patients who required postoperative assessment of residual bony abnormalities were selected. This article describes the CT-POD technique and the information required by the referring surgeon. CT-POD is a new technique that provides valuable preoperative and postoperative information to the surgeon.

  16. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  17. Study of CT Scan Flooding System at High Temperature and Pressure

    Science.gov (United States)

    Chen, X. Y.

    2017-12-01

    CT scan flooding experiment can scan micro-pore in different flooding stages by the use of CT scan technology, without changing the external morphology and internal structure of the core, and observe the distribution characterization in pore medium of different flooding fluid under different pressure.thus,it can rebuilt the distribution images of oil-water distribution in different flooding stages. However,under extreme high pressure and temperature conditions,the CT scan system can not meet the requirements. Container of low density materials or thin shell can not resist high pressure,while high density materials or thick shell will cause attenuation and scattering of X-ray. The experiment uses a simple Ct scanning systems.X ray from a point light source passing trough a micro beryllium shell on High pressure stainless steal container,continuously irradiates the core holder that can continuously 360° rotate along the core axis. A rare earth intensifying screen behind the core holder emitting light when irradiated with X ray can show the core X ray section image. An optical camera record the core X ray images through a transparency high pressure glazing that placed on the High pressure stainless steal container.Thus,multiple core X ray section images can reconstruct the 3D core reconstruction after a series of data processing.The experiment shows that both the micro beryllium shell and rare earth intensifying screen can work in high temperature and high pressure environment in the stainless steal container. This way that X-ray passes through a thin layer of micro beryllium shell , not high pressure stainless steal shell,avoid the attenuation and scattering of X-ray from the container shell,while improving the high-pressure experiment requirements.

  18. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  19. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  20. Childhood CT scans linked to leukemia and brain cancer later in life

    Science.gov (United States)

    Children and young adults scanned multiple times by computed tomography (CT), a commonly used diagnostic tool, have a small increased risk of leukemia and brain tumors in the decade following their first scan.

  1. Brain atrophy in Huntington's disease: A CT-scan study

    International Nuclear Information System (INIS)

    Starkstein, S.E.; Folstein, S.E.; Brandt, J.; McDonnell, A.; Folstein, M.

    1989-01-01

    CT-scan measurements of cortical and subcortical atrophy were carried out in 34 patients with Huntington's disease (HD). While a significant correlation was observed between parameters of subcortical atrophy (bicaudate ratio, bifrontal ratio and third ventricular ratio) and duration of the disease, there was no significant correlation between these parameters and age. On the other hand, measurements of cortical atrophy (frontal fissure ratio and cortical sulci ratio) correlated significantly with age but not with duration of the disease. When a group of 24 HD patients were compared on CT-scan measurements with a group of 24 age-matched normal controls, significant differences were obtained for all the variables examined, but the bicaudate ratio showed the highest sensitivity and specificity. Even mildly affected patients, with duration of motor symptoms less than 3 years had higher bicaudate ratios than age-matched controls. (orig.)

  2. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  3. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  4. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  5. Malignant pleural mesothelioma with heterologous osteoblastic differentiation: case report of the characteristic CT and bone scan findings

    International Nuclear Information System (INIS)

    Cho, Young Jun; Kim, Joung Sook; Kim, Ji Young; Choi, Soo Jeon; Choi, Sang Bong

    2008-01-01

    Malignant pleural mesothelioma is an uncommon neoplasm which is accompanied extremely rarely by osteoblastic heterologous elements. The CT manifestations of this tumor have been reported in several references. And, to our knowledge, only one case report provides a description of the bone scan findings. Here, we report the case of a rapidly progressing malignant pleural mesothelioma with heterologous osteoblastic elements. A CT scan reveals diffuse irregular pleural thickening and very coarse nodular calcifications along the right pleura and major fissure. A bone scan revealed an area of extensive increased radioactivity consistent with the pleural calcifications on the CT scan in the right hemithorax. A follow-up CT scan performed 40 days later suggests the presence of rapidly progressing nodular coarse calcifications

  6. Malignant pleural mesothelioma with heterologous osteoblastic differentiation: case report of the characteristic CT and bone scan findings

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Jun; Kim, Joung Sook; Kim, Ji Young; Choi, Soo Jeon; Choi, Sang Bong [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2008-06-15

    Malignant pleural mesothelioma is an uncommon neoplasm which is accompanied extremely rarely by osteoblastic heterologous elements. The CT manifestations of this tumor have been reported in several references. And, to our knowledge, only one case report provides a description of the bone scan findings. Here, we report the case of a rapidly progressing malignant pleural mesothelioma with heterologous osteoblastic elements. A CT scan reveals diffuse irregular pleural thickening and very coarse nodular calcifications along the right pleura and major fissure. A bone scan revealed an area of extensive increased radioactivity consistent with the pleural calcifications on the CT scan in the right hemithorax. A follow-up CT scan performed 40 days later suggests the presence of rapidly progressing nodular coarse calcifications.

  7. Advantage of CT scan in muscular pathology. Personal cases and review of the literature

    International Nuclear Information System (INIS)

    Laroche, M.; Rousseau, H.; Mazieres, B.; Bonafe, A.; Joffre, F.; Arlet, J.

    1989-01-01

    The advantage of CT scans in muscular pathology is studied. The scan, in addition to the diagnosis of tumors and muscular abscesses, permits to differentiate primary myopathies from neurogenic atrophies: in the course of myopathies, the muscle volume is preserved and they appear as a hypodensity; in neurogenic atrophies, the muscle volume is reduced with preserved density. The CT scan permits to determine the extension of these lesions. In the course of polymyositis, certain forms of rheumatid arthritis, the scan discloses a trabecular and 'worm-eaten' aspect of the muscles. This is also observed after long-term steroid therapy and other endocrine diseases (hyperthyroidism, osteomalacia) indicating an infra-clinical myopathy. In vertebral osteoporosis with fractures and patients with chronic lumbalgia, very ofter, an atrophy of the spinal muscle is observed. Finally, in the course of acquired kyphosis of the adult patient (camptocormia), the CT scan suggest an isolated myopathy, with late manifestations, of the paravertebral muscles [fr

  8. Advantage of CT scan in muscular pathology. Personal cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Laroche, M.; Rousseau, H.; Mazieres, B.; Bonafe, A.; Joffre, F.; Arlet, J.

    1989-05-01

    The advantage of CT scans in muscular pathology is studied. The scan, in addition to the diagnosis of tumors and muscular abscesses, permits to differentiate primary myopathies from neurogenic atrophies: in the course of myopathies, the muscle volume is preserved and they appear as a hypodensity; in neurogenic atrophies, the muscle volume is reduced with preserved density. The CT scan permits to determine the extension of these lesions. In the course of polymyositis, certain forms of rheumatid arthritis, the scan discloses a trabecular and 'worm-eaten' aspect of the muscles. This is also observed after long-term steroid therapy and other endocrine diseases (hyperthyroidism, osteomalacia) indicating an infra-clinical myopathy. In vertebral osteoporosis with fractures and patients with chronic lumbalgia, very ofter, an atrophy of the spinal muscle is observed. Finally, in the course of acquired kyphosis of the adult patient (camptocormia), the CT scan suggest an isolated myopathy, with late manifestations, of the paravertebral muscles.

  9. Evaluation of noninvasive tests for the preoperative staging of carcinoma of the esophagus: a prospective study

    International Nuclear Information System (INIS)

    Inculet, R.I.; Keller, S.M.; Dwyer, A.; Roth, J.A.

    1985-01-01

    A prospective study was undertaken to define the usefulness of conventional full-lung linear tomography, radionuclide liver plus spleen and bone scans, and thoracic and abdominal computed tomography for the preoperative staging of carcinoma of the esophagus. Thirty-three patients with carcinoma of the esophagus were studied. The computed tomographic (CT) scan of the thorax and upper abdomen was the single most accurate noninvasive study. With computed tomography, the relationship of the tumor to the tracheobronchial tree was the feature most useful in predicting local resectability. In all patients with the finding of tracheobronchial compression by the tumor, the tumor could not be resected completely. The predictive value of this CT finding in patients with locally unresectable tumor was high (0.83), indicating its usefulness in assessing unresectability. The CT finding of visible separation between tumor mass and tracheobronchial tree was present in 10 of 14 patients with locally resectable tumor (predictive value, 0.63). However, tumor abutting the tracheobronchial tree without compression was a poor predictor of unresectability (predictive value, 0.36). The radionuclide bone scan was the only other noninvasive study to demonstrate a metastasis not evident by CT scan. The combination of chest and abdominal CT scan, bone scan, and bronchoscopy before operation will accurately stage the majority of patients with esophageal cancer but no noninvasive test is of sufficient reliability to exclude patients from operative resection if otherwise indicated

  10. Preoperative Duplex Scanning is a Helpful Diagnostic Tool in Neurogenic Thoracic Outlet Syndrome.

    Science.gov (United States)

    Orlando, Megan S; Likes, Kendall C; Mirza, Serene; Cao, Yue; Cohen, Anne; Lum, Ying Wei; Freischlag, Julie A

    2016-01-01

    To evaluate the diagnostic role of venous and arterial duplex scanning in neurogenic thoracic outlet syndrome (NTOS). Retrospective review of patients who underwent duplex ultrasonography prior to first rib resection and scalenectomy (FRRS) for NTOS from 2005 to 2013. Abnormal scans included ipsilateral compression (IC) with abduction of the symptomatic extremity (>50% change in subclavian vessel flow), contralateral (asymptomatic side) compression (CC) or bilateral compression (BC). A total of 143 patients (76% female, average age 34, range 13-59) underwent bilateral preoperative duplex scanning. Ipsilateral compression was seen in 44 (31%), CC in 12 (8%), and BC in 14 (10%). Seventy-three (51%) patients demonstrated no compression. Patients with IC more often experienced intraoperative pneumothoraces (49% vs. 25%, P duplex ultrasonography can assist in NTOS diagnosis. Ipsilateral compression on abduction often correlates with Adson testing. © The Author(s) 2016.

  11. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  12. The value of FDG positron emission tomography/computerised tomography (PET/CT) in pre-operative staging of colorectal cancer: a systematic review and economic evaluation.

    Science.gov (United States)

    Brush, J; Boyd, K; Chappell, F; Crawford, F; Dozier, M; Fenwick, E; Glanville, J; McIntosh, H; Renehan, A; Weller, D; Dunlop, M

    2011-09-01

    In the UK, colorectal cancer (CRC) is the third most common malignancy (behind lung and breast cancer) with 37,514 cases registered in 2006: around two-thirds (23,384) in the colon and one-third (14,130) in the rectum. Treatment of cancers of the colon can vary considerably, but surgical resection is the mainstay of treatment for curative intent. Following surgical resection, there is a comprehensive assessment of the tumour, it's invasion characteristics and spread (tumour staging). A number of imaging modalities are used in the pre-operative staging of CRCs including; computerised tomography (CT), magnetic resonance imaging, ultrasound imaging and positron emission tomography (PET). This report examines the role of CT in combination with PET scanning (PET/CT 'hybrid' scan). The research objectives are: to evaluate the diagnostic accuracy and therapeutic impact of fluorine-18-deoxyglucose (FDG) PET/CT for the pre-operative staging of primary, recurrent and metastatic cancer using systematic review methods; undertake probabilistic decision-analytic modelling (using Monte Carlo simulation); and conduct a value of information analysis to help inform whether or not there is potential worth in undertaking further research. For each aspect of the research - the systematic review, the handsearch study and the economic evaluation - a database was assembled from a comprehensive search for published and unpublished studies, which included database searches, reference lists search and contact with experts. In the systematic review prospective and retrospective patient series (diagnostic cohort) and randomised controlled trials (RCTs) were eligible for inclusion. Both consecutive series and series that are not explicitly reported as consecutive were included. Two reviewers extracted all data and applied the criteria independently and resolved disagreements by discussion. Data to populate 2 × 2 contingency tables consisting of the number of true positives, true negatives

  13. Two methods for isolating the lung area of a CT scan for density information

    International Nuclear Information System (INIS)

    Hedlund, L.W.; Anderson, R.F.; Goulding, P.L.; Beck, J.W.; Effmann, E.L.; Putman, C.E.

    1982-01-01

    Extracting density information from irregularly shaped tissue areas of CT scans requires automated methods when many scans are involved. We describe two computer methods that automatically isolate the lung area of a CT scan. Each starts from a single, operator specified point in the lung. The first method follows the steep density gradient boundary between lung and adjacent tissues; this tracking method is useful for estimating the overall density and total area of lung in a scan because all pixels within the lung area are available for statistical sampling. The second method finds all contiguous pixels of lung that are within the CT number range of air to water and are not a part of strong density gradient edges; this method is useful for estimating density and area of the lung parenchyma. Structures within the lung area that are surrounded by strong density gradient edges, such as large blood vessels, airways and nodules, are excluded from the lung sample while lung areas with diffuse borders, such as an area of mild or moderate edema, are retained. Both methods were tested on scans from an animal model of pulmonary edema and were found to be effective in isolating normal and diseased lungs. These methods are also suitable for isolating other organ areas of CT scans that are bounded by density gradient edges

  14. Clinical value of surgical staging with preoperative 18F-FDG PET/CT evaluation for mediastinal lymph nodes in lung cancer

    International Nuclear Information System (INIS)

    Li Hong; Wang Xiaoming; Xu Weina; Xin Jun; Guo Qiyong

    2012-01-01

    Objective: To investigate the clinical value of preoperative 18 F-FDG PET/CT for surgical staging by evaluating mediastinal lymphadenopathy in lung cancer. Methods: Sixty-eight patients with lung cancer underwent both 18 F-FDG PET/CT and chest CT. The results of PET/CT and CT were compared with pathological results. χ 2 and t tests were used for data analysis. Results: A total of 222 mediastinal lymph nodes were resected in 68 patients and 84 (37.8%) were confirmed as metastases by pathology. The sensitivity, specificity, accuracy, positive and negative predictive values for PET/CT and CT were 71.4% (60/84) vs 48.8% (41/84), 66.7% (92/138) vs 49.3% (68/138), 68.5% (152/222) vs 49.1%(109/222), 56.6% (60/106) vs 36.9% (41/111), 79.3% (92/116) vs 61.3 % (68/111), respectively (χ 2 =8.96, 8.57, 17.19, 8.43, 8.88, all P<0.05). The staging consistency of PET/CT with pathology was 73.5% (50/68), which was significantly higher than that of CT with pathology (41.2% (28/68); χ 2 =14.55, P<0.01). The identification of N 1 and N 2 disease was, respectively, 66.7%(10/15) and 79.2% (19/24) by PET/CT, 13.3%(2/15) and 45.8% (11/24) by CT (χ 2 =8.89 and 5.69, both P<0.05). The SUV max of lymph nodes greater than and equal to 10 mm in short diameter was significantly higher than those with short diameters less than 10 mm (5.5±2.8 vs 2.2±0.9, t=5.17, P<0.05). Conclusion: Preoperative 18 F-FDG PET/CT is more accurate for evaluating mediastinal lymphadenopathy and staging in patients with lung cancer than CT, and therefore is more valuable for optimizing the best treatment strategies. (authors)

  15. Repeat CT-scan assessment of lymph node motion in locally advanced cervical cancer patients

    International Nuclear Information System (INIS)

    Bondar, Luiza; Velema, Laura; Mens, Jan Willem; Heijmen, Ben; Hoogeman, Mischa; Zwijnenburg, Ellen

    2014-01-01

    In cervical cancer patients the nodal clinical target volume (CTV, defined using the major pelvic blood vessels and enlarged lymph nodes) is assumed to move synchronously with the bony anatomy. The aim of this study was to verify this assumption by investigating the motion of the major pelvic blood vessels and enlarged lymph nodes visible in CT scans. For 13 patients treated in prone position, four variable bladder-filling CT scans per patient, acquired at planning and after 40 Gy, were selected from an available dataset of 9-10 CT scans. The bladder, rectum, and the nodal-vessels structure containing the iliac vessels and all visible enlarged nodes were delineated in each selected CT scan. Two online patient setup correction protocols were simulated. The first corrected bony anatomy translations and the second corrected translations and rotations. The efficacy of each correction was calculated as the overlap between the nodal-vessels structure in the reference and repeat CT scans. The motion magnitude between delineated structures was quantified using nonrigid registration. Translational corrections resulted in an average overlap of 58 ± 13% and in a range of motion between 9.9 and 27.3 mm. Translational and rotational corrections significantly improved the overlap (64 ± 13%, p value = 0.007) and moderately reduced the range of motion to 7.6-23.8 mm (p value = 0.03). Bladder filling changes significantly correlated with the nodal-vessels motion (p [de

  16. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  17. Preoperative Prediction of Ki-67 Labeling Index By Three-dimensional CT Image Parameters for Differential Diagnosis Of Ground-Glass Opacity (GGO.

    Directory of Open Access Journals (Sweden)

    Mingzheng Peng

    Full Text Available The aim of this study was to predict Ki-67 labeling index (LI preoperatively by three-dimensional (3D CT image parameters for pathologic assessment of GGO nodules. Diameter, total volume (TV, the maximum CT number (MAX, average CT number (AVG and standard deviation of CT number within the whole GGO nodule (STD were measured by 3D CT workstation. By detection of immunohistochemistry and Image Software Pro Plus 6.0, different Ki-67 LI were measured and statistically analyzed among preinvasive adenocarcinoma (PIA, minimally invasive adenocarcinoma (MIA and invasive adenocarcinoma (IAC. Receiver operating characteristic (ROC curve, Spearman correlation analysis and multiple linear regression analysis with cross-validation were performed to further research a quantitative correlation between Ki-67 labeling index and radiological parameters. Diameter, TV, MAX, AVG and STD increased along with PIA, MIA and IAC significantly and consecutively. In the multiple linear regression model by a stepwise way, we obtained an equation: prediction of Ki-67 LI=0.022*STD+0.001* TV+2.137 (R=0.595, R's square=0.354, p<0.001, which can predict Ki-67 LI as a proliferative marker preoperatively. Diameter, TV, MAX, AVG and STD could discriminate pathologic categories of GGO nodules significantly. Ki-67 LI of early lung adenocarcinoma presenting GGO can be predicted by radiologic parameters based on 3D CT for differential diagnosis.

  18. 18F-FDG PET/CT prediction of malignant versus benign lesion in patients presenting with adnexal mass

    DEFF Research Database (Denmark)

    Frost, Majbritt; Iyer, Victor Vishwanath; Fisker, Rune Vincents

    2011-01-01

    classified as benign or malignant and the results were compared with the registered intra-operative findings and the final histopathological examination. Preoperative 18F-FDG PET/CT-based staging was compared to the final histopathological staging according to FIGO 2003. Results: The preliminary results......%] and a specificity of 76 % CI: [63; 87%]. Conclusions: 18F-FDG PET/CT-scanning can be useful for preoperative differentiation between benign and malignant adnexal masses. Furthermore, as a whole-body examination with intravenous contrast, it gives useful information of metastasis extent of malignant diseases...

  19. Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind

    International Nuclear Information System (INIS)

    Michel, Morgane; Jacob, Sophie; Roger, Gilles; Pelosse, Béatrice; Laurier, Dominique; Le Pointe, Hubert Ducou; Bernier, Marie-Odile

    2012-01-01

    Objectives: The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Methods: Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Results: Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7 mSv and 168 mGy, respectively. Conclusion: A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients’ families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT.

  20. Use of (18)F-FDG PET/CT in the preoperative evaluation of patients diagnosed with peritoneal carcinomatosis of ovarian origin, candidates to cytoreduction and hipec. A pending issue.

    Science.gov (United States)

    Lopez-Lopez, V; Cascales-Campos, P A; Gil, J; Frutos, L; Andrade, R J; Fuster-Quiñonero, M; Feliciangeli, E; Gil, E; Parrilla, P

    2016-10-01

    To evaluate the clinical usefulness of the results obtained with (18)F-FDG PET/CT in relation to CT in the preoperative staging of patients with peritoneal carcinomatosis secondary to primary or recurrent ovarian cancer candidates to cytoreductive surgery and hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC). A retrospective study comparing the results obtained with CT and (18)F-FDG PET/CT in the preoperative evaluation of a series of 59 patients was performed. In all patients the peritoneal carcinomatosis index (PCI) was determined by preoperative radiological CT and 18F-FDG PET/CT and compared with surgical PCI, which was considered as reference. Of the 59 patients studied, in 55 peritoneal carcinomatosis presences were confirmed (4 patients had complete responses to neoadjuvant chemotherapy). The mean surgical, CT and 18F-FDG PET/CT PCI was 9.46±7.70, 3.69±3.96 and 2.25±1.02, respectively. In the global disease detection, CT showed a higher positive likelihood ratio (LR+) than (18)F-FDG PET/CT (15.3, 95% CI 8.35-28.04 vs. 3.47, 95% CI 3.36-5.11) and a lower negative likelihood ratio (LR-) than 18F-FDG PET/CT (0.67, 95% CI 0.61-0.73 vs. 0.82, 95% CI 0.76-0.88). In every region of the abdomen the CT showed a greater LR+ than 18F-FDG PET/CT and a lower LR- than 18F-FDG PET/CT. CT showed the best diagnostic results compared to (18)F-FDG PET/CT to confirme the presence of peritoneal disease. The lower performance of the (18)F-FDG PET/CT suggests that the main utility of (18)F-FDG PET/CT is to evaluate a possible metastatic extraperitoneal spread of the disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Study on CT scanning technique of inferior horn of lateral ventricle

    International Nuclear Information System (INIS)

    Kakoi, Iwao; Okubo, Mitsuo; Nakamura, Sumio; Yoshinaga, Toshihiko; Shimono, Tetsuo

    1984-01-01

    It is said that temporal lobe epilepsy (TLE), one of the incurable epilepsies, results from the lesions of various structrues located in the medial and deep portion of the temporal lobe such as the hippocampus and amygdaloid nucleus. Routine CT scanning techniques cannot adequately delineate these structures in the assessment of TLE. The anatomical relationship between these medial temporal structures and the inferior horn of lateral ventricle which is lateral to them and easily identified by CT lead us to believe that the sections through the longitudinal plane of the inferior horn may clearly delineate them. The present experimental study was undertaken to develop the CT scan technique of the inferior horn of lateral ventricle, which results in the clear delineation of the region of the hippocampus and amygdaloid nucleus. As a result, A total of the 3-4 reversed axial 5 mm-thick section centered at 2.5 cm cephalad to the roof of the external auditory canal at a reversed 25 0 angle to ABL are adequate to delineate the inferior horn and the medial temporal structures. This scan technique is considered to be useful in the assessment of TLE. (author)

  2. Pre-operative concurrent chemoradiotherapy for stage IIIA (N2) Non-Small cell lung cancer

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Ahn, Yong Chan; Park, Keun Chil

    1999-01-01

    This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45-67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in 12, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal lymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intraventous cis-Platin (100 mg/m 2 ) on day 1 and oral Etoposide (50 mg/m 2 /day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred in 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/13) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative tumor

  3. Pre-operative concurrent chemoradiotherapy for stage IIIA (N2) Non-Small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyu Chan; Ahn, Yong Chan; Park, Keun Chil [College of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)] [and others

    1999-06-01

    This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45-67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in 12, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal lymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intraventous cis-Platin (100 mg/m{sup 2}) on day 1 and oral Etoposide (50 mg/m{sup 2}/day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred in 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/13) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post

  4. Preoperative embolization of gigantic meningioma

    International Nuclear Information System (INIS)

    Wang Hongsheng; Chen Huaqun; Dong Congsong; Li Wenhui; Dai Zhenyu; Chen Guozhi

    2006-01-01

    Objective: To evaluate the clinical efficacy of preoperative embolization in treatment of patients with gigantic meningioma. Methods: Fourteen cases of gigantic meningioma diameter from 6 to 11 cm were measured by CT and MRI scan. DSA manifested that they are vascularizd meningioma and showed the mainly feeding arteries. We used getation sponge to superselectively embilized the feeding arteries. All tumors were performed surgical excision 3-7 days after the embolization. Results: DSA showed the blood supplies in the tumors in 9 cases were completely blocked, and that in 5 cases were dramatically eliminated. All patients were operated 3-7 days after the embolization. During the operations the bleeding were dramatically decreased and the operation time was shortened compared with those in unembolized cases. It helps us remove the tumors easy and quickly from the attachments. No complication occurred during and after the operations. Conclusion: Preoperative embolization of gigantic meningioma is a useful and relatively safe method in helping surgicaly and completely excised of tumor with significant reduction of blood loss and operation time. (authors)

  5. Image analysis of the inner ear with CT and MR imaging

    International Nuclear Information System (INIS)

    Kumakawa, Kohzoh; Takeda, Hidehiko; Mutoh, Naoko; Miyakawa, Kohichi; Yukawa, Kumiko; Funasaka, Sohtaro.

    1992-01-01

    Recent progress in magnetic resonance imaging (MRI) has made it possible to obtain detailed images of the inner ear by delineating the lymphatic fluid within the labyrinth. We analyzed CT scans and MR imaging in 70 ears manifesting profound deafness owing to inner ear lesions and compared their detective ability for inner ear lesions. The following results were obtained. CT scan examination showed slight to extensive ossification of the labyrinth in six ears (9%), whereas MRI examination revealed low to absent signal intensity of the inner ear in nine ears (13%). Therefore, it was concluded that MRI is more sensitive in detecting abnormalities of the inner ear than CT scan. MRI provided useful information as to whether the cochlear turn is filled with lymphatic fluid or obstructed. This point was one of the greatest advantages of MRI over CT scan. Abnormal findings in either or both the CT scan and the MRI were detected in suppurative labyrinthitis occurring secondary to chronic otitis media, bacterial meningitis and in inner ear trauma. However, such abnormal findings were not detected in patients with idiopathic progressive sensorineural hearing loss, ototoxity or sudden deafness. These findings should be taken into consideration in pre-operative assessment of cochlear implant candidates. (author)

  6. Intrathoracic kidney. Diagnostic value of CT scan imaging

    International Nuclear Information System (INIS)

    Baillet, A.M.; Escure, M.N.

    1988-01-01

    Two cases are reported of an ectopic right kidney that was partially intrathoracic in position. Diagnosis was simple from CT scan imaging appearances, the examination being performed to investigate an intrathoracic mass. Images showed a tissular mass within a fatty zone in sections without contrast and the typical appearance of the kidney on sections with contrast [fr

  7. Correlation between image quality of CT scan and amount of intravenous contrast media

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Choi, Dae Seob; Kim, Seung Hyup; Han, Joon Koo; Choi, Byung Ihn; Im, Jung Gi; Han, Moon Hee; Chang, Kee Hyun; Kim, Jong Hyo; Han, Man Chung

    1993-01-01

    A blind, comparative clinical study was performed prospectively to examine the correlation between image quality of CT scan in terms of contrast enhancement effect and amount of intravenous contrast media. A total of 357 patients were randomized into two groups. Ionic high-osmolality contrast media (68% meglumine ioglicate) was administered intravenously as 100 ml bolus in one group and as 50 ml bolus in the other group. Statistically significant differences of image quality were found in CT scans of the brain, head and neck, chest and abdomen (p 0.05). We suggest that amount of contrast media may be reduced in pelvis CT without significant degradation of image quality

  8. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  9. Study of CT head scans using different voltages: image quality evaluation

    International Nuclear Information System (INIS)

    Pacheco de Freitas C, I.; Prata M, A.; Alonso, T. C.; Santana, P.

    2016-10-01

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  10. Role of preoperative PET-CT in assessing mediastinal and hilar lymph node status in early stage lung cancer

    Directory of Open Access Journals (Sweden)

    Wei-Yang Lin

    2012-05-01

    Conclusion: Integrated PET-CT is a useful tool for predicting the negativity of mediastinal LN status pre-operatively in clinically early stage (Stages I and II lung cancer but may be relatively inaccurate in predicting hilar LN status and largely confounded by false positives caused by inflammatory process.

  11. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  12. CT scanning in Australia: a report by the National Health Technology Advisory Panel

    International Nuclear Information System (INIS)

    1988-06-01

    An overview of trends in the usage of CT scanning in Australia is given and the areas of benefit and uncertainty associated with this technology are outlined. Numbers and distribution of CT units, costs of CT services, clinical applications, safety aspects and the effects of new developments are discussed. 54 refs., 5 figs., 18 tabs

  13. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  14. Preoperative staging of esophageal carcinoma with multidetector CT and virtual endoscopy

    International Nuclear Information System (INIS)

    Onbas, Omer; Eroglu, Atilla; Kantarci, Mecit; Polat, Pinar; Alper, Fatih; Karaoglanoglu, Nurettin; Okur, Adnan

    2006-01-01

    Purpose: The aim of this study was to assess the accuracy of multidetector computed tomography (MDCT), including virtual endoscopy (VE) for detection, precise localization, preoperative evaluation and staging of esophageal cancer (EC) by comparison with surgical and histopathological findings. Materials and methods: Between September 2003 and April 2005, 44 patients with histologically proven EC underwent MDCT and VE. Among 44 patients, the findings were confirmed in 24 at surgery. The accuracy of three-dimensional MDCT for detection, localization, and staging of EC was determined, and compared with surgical finding and histopathology. Results: The overall accuracy of three-dimensional multidetector row CT for detection of EC was 100% (24/24). MDCT staging was correct in 20 patients (83.3%). The T parameter was correctly assessed in 22 (91.7%) cases (understaged in 1 and overstaged in 1). The N parameter was correctly evaluated in 20 (83.4%) patients (understaged in 2 and overstaged in 2). The overall accuracy of VE for the morphologic classification of EC was 81.5%. Conclusions: Three-dimensional MDCT, along with VE is a promising method for preoperative evaluation and staging of EC. Although accuracy in N staging remains low in comparison to PET, it provides a larger amount of diagnostic and staging information

  15. Fibroelastic pseudotumor elastofibroma dorsi detected by 18F-FDG PET/CT scan and by postherapy radioiodine SPECT/CT.

    Science.gov (United States)

    Oporto, M; Cepa, F; Orta, N; Rubí, S; Navalón, H; Peña, C

    Radioiodine uptake in the thyroid tissue, metastasis of differentiated thyroid cancer (DTC), and in other tissues, depends on the expression of sodium-iodide symporter (NIS). Vascular permeability, effusions, inflammation, and other mechanisms may also play a role in the accumulation of radioactive iodine. A 63-year-old woman underwent radioiodine therapy, as well as a post-therapy whole-body scan, as she was suspected of having lung metastasis from thyroid carcinoma. The scan not only showed uptake at the lung metastasis but also a faint diffuse bilateral uptake in the posterior thorax. On SPECT/CT this uptake was located in a known Elastofibroma Dorsi (ED) previously diagnosed by contrast CT and viewed in a FDG PET/CT. The radioiodine uptake in ED, especially if typical, is not a diagnostic problem in SPECT/CT study, but can be misleading in a study limited to a few planar images, particularly if the uptake occurs asymmetrically, or ED is located in a unsuspected area. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. Preoperative radiological assessment of children with pectus excavatum

    International Nuclear Information System (INIS)

    Kilda, A.; Barauskas, V.; Basevicius, A.; Lukosevicius, S.

    2005-01-01

    Objective: The degree of the pediatric chest deformation that should be subjected to corrective surgical treatment or conservative treatment remains poorly defined as recognized. In the present study, using preoperative and postoperative radiological examination data, we aim to assess what degree of chest wall deformation changes statistically reliably after surgery. Materials and methods: Radiological chest examinations were performed for 88 children before and after remedial operations. Chest X-ray and CT scans were done to measure transversal chest width; sagittal left chest side depth, sagittal right chest side depth, sternovertebral distance, and vertebral body length. Derivative indices were also estimated: the Vertebral Index, the Frontosagittal Index, the Haller index, and the asymmetry index. Computerized assessment of data was used. For statistical analysis, the software 'STATISTICA 6.0' was used. Results: Postoperatively, the Vertebral Index increased approximately by 2.37±2.72; the Frontosagittal Index decreased by 4.60±4.34, and the Haller index value increased approximately up by 0.45±0.49. Statistically reliable deformation index difference before and after surgery was not detected when the Vertebral Index was below 26.2, p=0.08; the Frontosagittal Index was above 32.9, p=0.079; and the Haller Index was less than 3.12, p=0.098. Conclusions: Preoperative CT scanning, coupled with assessment of the chest wall shape and the deformation degree, would be necessary for pediatric patients. The following deformation indices are indications for surgical treatment: VI > 26, FSI 3.1. (author)

  17. [Automated detection and volumetric segmentation of the spleen in CT scans].

    Science.gov (United States)

    Hammon, M; Dankerl, P; Kramer, M; Seifert, S; Tsymbal, A; Costa, M J; Janka, R; Uder, M; Cavallaro, A

    2012-08-01

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like "marginal space learning" and "boosting algorithms". 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm³ + 0.58 (width × length × thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 (± 2.4) seconds. The average splenic volume measured by aV was 268.21 ± 114.67 cm³ compared to 281.58 ± 130.21 cm³ in mV and 268.93 ± 104.60 cm³ in eV. The correlation coefficient was 0.99 (coefficient of determination (R²) = 0.98) for aV and mV, 0.91 (R² = 0.83) for mV and eV and 0.91 (R² = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R² = 0.84), mV and eV (0.95; R² = 0.91) and aV and eV (0.83; R² = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Automated detection and volumetric segmentation of the spleen in CT scans

    International Nuclear Information System (INIS)

    Hammon, M.; Dankerl, P.; Janka, R.; Uder, M.; Cavallaro, A.; Kramer, M.; Seifert, S.; Tsymbal, A.; Costa, M.J.

    2012-01-01

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like ''marginal space learning'' and ''boosting algorithms''. 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm 3 + 0.58 (width x length x thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 (± 2.4) seconds. The average splenic volume measured by aV was 268.21 ± 114.67 cm 3 compared to 281.58 ± 130.21 cm 3 in mV and 268.93 ± 104.60 cm 3 in eV. The correlation coefficient was 0.99 (coefficient of determination (R 2 ) = 0.98) for aV and mV, 0.91 (R 2 = 0.83) for mV and eV and 0.91 (R 2 = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R 2 = 0.84), mV and eV (0.95; R 2 = 0.91) and aV and eV (0.83; R 2 = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. (orig.)

  19. Proposed radiological criteria for pre-operative determination of resectability in peritoneal-based malignancies

    International Nuclear Information System (INIS)

    Tan, Grace Hwei Ching; Chanyaputhipong, Jendana; Teo, Melissa Ching Ching; Kwek, Jin Wei; Hosseini, Reza; Tham, Chee Kian; Soo, Khee Chee

    2016-01-01

    The selection of patients for cytoreductive surgery (CRS) and hyperthermic intra-peritoneal chemotherapy infusion (HIPEC) is important, and relies heavily on imaging. However, it has been reported that Computer Tomographic (CT) scans may only achieve a low sensitivity of 33% for peritoneal disease. We propose a set of radiological criteria for pre-operative determination of resectability of peritoneal disease in peritoneal-based malignancies and validate this in our cohort of patients. A retrospective review of all patients who underwent laparotomy with a view for CRS and HIPEC, at the National Cancer Centre Singapore from January 2000 to April 2010, was performed. Intra-operative Peritoneal Cancer Index (PCI) scores were recorded. The pre-operative imaging was reviewed with a senior radiologist who was blinded, and recorded the radiological PCI scores (CT-PCI) and eight additional CT prognostic factors (CT-PF). The CT-PCI and CT-PF scores were then compared with the intra-operative findings to determine the radiological accuracy. The scores and the individual prognostic factors were then evaluated for their predictive ability for unresectability. Comparison of the CT-PCI and PCI scores showed a concordance correlation coefficient at 0.52 (95% CI 0.34–0.7). Accuracy was increased with the addition CT-PF. The presence of omental caking and ascites were predictors of unresectability. We propose a scoring system which is able to predict for unresectable disease with a specificity of 80% and a sensitivity of 62%. With our proposed criteria, and scoring system, the selection of patients for CRS and HIPEC can be improved, and unnecessary exploratory operations avoided.

  20. Analysis of lenses absorbed dose in head CT scan with the use of bismuth shielding

    Energy Technology Data Exchange (ETDEWEB)

    Santos, F.S.; Santana, P.C., E-mail: fernanda.stephaniebh@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil); Mourão, A.P. [Centro de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. However, CT scan usually requires a higher radiation exposure than a conventional radiography examination. Head CT scans are used for diagnosis of traumatic head injuries, infections and other diseases with instability. Based on this information, it was studied the dose variation deposited in the lenses and in nearby organs, such as: pharynx, hypophysis and salivary gland with and without the use of bismuth shield. In this study a head CT scan was performed on anthropomorphic male phantom using a GE scanner. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. The results show that the lenses had a reduction of 26% of the dose with the use of the bismuth shield. (author)

  1. Anatomical and embryological considerations of renal vein abnormalities: The value of preoperative CT

    International Nuclear Information System (INIS)

    Hruby, W.; Hoelti, W.

    1986-01-01

    Renal vein abnormalities are an uncommon kind of vascular abnormality. The distribution in the general population is 1.5%-2.5% in unselected pathologic material. In 354 autopsies we have seen six cases of renal vein abnormalities; in 215 cases of major retroperitoneal surgery, seven renal vein abnormalities; and in 4,500 patients who underwent CT examinations of the retroperitoneal areas, 36 cases of atypical renal vein anatomy. The radiologist must be familiar with embryologic details to understand the development of renal vein abnormalities. The authors discuss the value of preoperative diagnosis for preventing a surgical disaster in major retroperitoneal surgery

  2. Dose assessment of head CT examination by volume scanning with 320-area-detector

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Kobayashi, Masanao

    2009-01-01

    CT with the 320-area-detector (320-ADCT), first presented in 2007, still requires further basic studies, particularly in the field of dose assessment, as the CT has been widely spread in clinic due to its many advantages compared with the usual spiral CT. In this paper, the assessment in the title was thereby done in human phantom and a patient with suspicious acute cerebral infarction under different scanning modes (non-spiral, spiral and volume) for their comparison. Machines for 320-ADCT, and non-spiral and spiral CT were Toshiba Aquilion ONE, and Aquilion 64-MD, respectively. Scanning of the phantom and patient was individually conducted under similar conditions of tube voltage/ current, rotation time and length with the same field of view with defined nominal slice thicknesses. Alderson human body phantom in which 240 thermoluminescent dosimeters were indwelled, was used; doses were read by the thermoluminescence dosimeter (TLD) reader model 3000 (Kyokko Co.) after scanning; and effective doses were calculated with reference to ICRP publ. 102/103 equations for patient's head to be 4.2 (64-MDCT) and 6.6 (320-ADCT) mSv, which were respectively 6.4 and 5.4 mSv when estimated using the conversion coefficient and DLP (dose length product) in the texts. It was suggested that the exposure dose at the volume scanning by 320-ADCT can be reduced in the routine examination, and in the exact diagnosis, possibly increases. These doses can be reduced further by optimization of scanning conditions by additional basic investigations. (K.T.)

  3. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    Science.gov (United States)

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  4. Hybrid imaging with contrast enhanced CT scan: A nuclear physician's point of view

    International Nuclear Information System (INIS)

    Houzard, C.; Tychyj-Pinel, C.; Defez, D.; Valette, P.J.; Giammarile, F.; Houzard, C.; Valette, P.J.; Giammarile, F.

    2010-01-01

    The ongoing development of hybrid imaging, with physical association of CT scan and PET or SPECT scan, allows integrating morphological and functional information on a single exam. This important technological evolution changes diagnostic and therapeutic strategy in a major manner, essentially in oncology. The possibility to inject intravenously iodinated contrast media in order to enhance CT image contrast is still a controversial question in France. We present our experience in this domain by approaching technical problems and diagnostic advantages. (authors)

  5. Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning.

    Science.gov (United States)

    Li, Jun Yuan; Pow, Edmond Ho Nang; Zheng, Li Wu; Ma, Li; Kwong, Dora Lai Wan; Cheung, Lim Kwong

    2014-04-01

    To investigate the impact of cover screw, resin embedment, and implant angulation on artifact of microcomputed tomography (micro-CT) scanning for implant. A total of twelve implants were randomly divided into 4 groups: (i) implant only; (ii) implant with cover screw; (iii) implant with resin embedment; and (iv) implants with cover screw and resin embedment. Implants angulation at 0°, 45°, and 90° were scanned by micro-CT. Images were assessed, and the ratio of artifact volume to total volume (AV/TV) was calculated. A multiple regression analysis in stepwise model was used to determine the significance of different factors. One-way ANOVA was performed to identify which combination of factors could minimize the artifact. In the regression analysis, implant angulation was identified as the best predictor for artifact among the factors (P  0.05). Non-embedded implants with the axis parallel to X-ray source of micro-CT produced minimal artifact. Implant angulation and resin embedment affected the artifact volume of micro-CT scanning for implant, while cover screw did not. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  7. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  8. Implementation of dual energy CT scanning

    International Nuclear Information System (INIS)

    Marshall, W.; Hall, E.; Doost-Hoseini, A.; Alvarez, R.; Macovski, A.; Cassel, D.

    1984-01-01

    A prereconstruction method for dual energy (PREDECT) analysis of CT scans is described. In theory, this method can (a) eliminate beam hardening and produce an accuracy comparable with monoenergetic scans and (b) provide the effective atomic number and electron density of any voxel scanned. The implementation proves these statements and eliminates some of the objectionable noise. A phantom was constructed with a cylindrical sleeve-like compartment containing known amounts of high atomic number material simulating a removable skull. Conventional scans, with and without this beam hardener, were done of a water bath containing tubes of high electron and high atomic number material. Dual energy scans were then done for PREDECT. To increase the effective separation of the low and high energy beams by using more appropriate tube filtration, a beam filter changer was fabricated containing erbium, tungsten, aluminum, and steel. Erbium, tungsten, and steel were used at high energy and aluminum, steel, and erbium at low energy for data acquisition. The reconstructions were compared visually and numerically for noise levels with the original steel only filtration. A decrease was found in noise down to approximately one-half the prior level when erbium/aluminum or tungsten/aluminum replaced the steel/steel filter. Erbium and tungsten were equally effective. Steel/erbium and steel/aluminum also significantly reduced image noise. The noise in the photoelectric (P) and Compton (C) images is negatively correlated. At any pixel, if the noise is positive in the P image, it is most probably negative in the C. Using this fact, the noise was reduced by postreconstruction processing

  9. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    Science.gov (United States)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  10. Surgical outcome prediction in patients with advanced ovarian cancer using computed tomography scans and intraoperative findings

    Directory of Open Access Journals (Sweden)

    Ha-Jeong Kim

    2014-09-01

    Conclusion: The combination of omental extension to the stomach or spleen and involvement of inguinal or pelvic lymph nodes in preoperative CT scans is considered predictive of suboptimal cytoreduction. These patients may be more appropriately treated with neoadjuvant chemotherapy followed by surgical cytoreduction.

  11. The use of CT-scanning at the medicolegal external postmortem examination and at the forensic autopsy

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2006-01-01

    Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn and Sønde...

  12. Diagnostic performance of 64-section CT using CT gastrography in preoperative T staging of gastric cancer according to 7th edition of AJCC cancer staging manual

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Jeong, Yong Yeon; Kang, Heoung Keun; Choi, Yoo Duk; Park, Young Kyu; Park, Chang Hwan

    2012-01-01

    To evaluate the accuracy of 64-section multidetector CT with CT gastrography for determining the depth of mural invasion in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. A total of 127 patients with gastric cancer and who had undergone both esophago-gastro-duodenoscopy and 64-section CT were included in this study. Two radiologists independently reviewed the preoperative CT images with respect to the detectability and T-staging of the gastric cancers. The sensitivity, specificity, accuracy and overall accuracy of each reviewer for the T staging of gastric cancer were calculated. Overall, gastric cancer was detected in 123 (96.9%) of the 127 cancers on the CT images. Reviewer 1 correctly staged 98 gastric cancers, and reviewer 2 correctly classified 105 gastric cancers. The overall diagnostic accuracy of the T staging was 77.2% (98/127) for reviewer 1 and 82.7% (105/127) for reviewer 2. 64-section CT using CT gastrography showed a reasonable diagnostic performance for determining the T staging in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. (orig.)

  13. Effect of clinical information in brain CT scan interpretation : a blinded double crossover study

    International Nuclear Information System (INIS)

    Zhianpour, M.; Janghorbani, M.

    2004-01-01

    Errors and variations in interpretation can happen in clinical imaging. Few studies have examined the biased effect of clinical information on reporting of brain CT scans. In a blinded double crossover design, we studied whether three radiologists were biased by clinical information when making CT scan diagnosis of the brain. Three consultant radiologists in three rounds with at least a one month interval assessed 100 consecutive cases of brain CT scan. In the first round, clinical information was not available and 100 films without clinical information were given to radiologists. In the second round, the same 100 films were given and true clinical information was available. In the third round, the same 100 films were given and false clinical information was allocated. In 180 cases (60%) the evaluation resulted in the same diagnosis on all three occasions (95% confidence interval (CI): 54.5, 65.5), whereas 120(40%; 95% CI:34.5, 45.5) sets were evaluated differently. 48 cases (16%; 95% CI:11.9,20.1) had discordant evaluation with true and 33 (11%; 95% CI:7.5, 14.5) with false clinical information. Discordance without and with true and false clinical information was 39 (13%; 95% CI:9.2, 16.8). Correct clinical information improves the brain CT report, while the report became less accurate false clinical information was allocated. These results indicate that radiologists are biased by clinical information when reporting brian CT scans

  14. 'Peripheric' pancreatic cysts: performance of CT scan, MRI and endoscopy according to final pathological examination.

    Science.gov (United States)

    Duconseil, P; Turrini, O; Ewald, J; Soussan, J; Sarran, A; Gasmi, M; Moutardier, V; Delpero, J R

    2015-06-01

    To assess the accuracy of pre-operative staging in patients with peripheral pancreatic cystic neoplasms (pPCNs). From 2005 to 2011, 148 patients underwent a pancreatectomy for pPCNs. The pre-operative examination methods of computed tomography (CT), magnetic resonance imaging (MRI), endoscopic ultrasonography (EUS) were compared for their ability to predict the suggested diagnosis accurately, and the definitive diagnosis was affirmed by pathological examination. A mural nodule was detected in 34 patients (23%): only 1 patient (3%) had an invasive pPCN at the final histological examination. A biopsy was performed in 79 patients (53%) during EUS: in 55 patients (70%), the biopsy could not conclude a diagnosis; the biopsy provided the correct and wrong diagnosis in 19 patients (24%) and 5 patients (6%), respectively. A correct diagnosis was affirmed by CT, EUS and pancreatic MRI in 60 (41%), 103 (74%) and 80 (86%) patients (when comparing EUS and MRI; P = 0.03), respectively. The positive predictive values (PPVs) of CT, EUS and MRI were 70%, 75% and 87%, respectively. Pancreatic MRI appears to be the most appropriate examination to diagnose pPCNs accurately. EUS alone had a poor PPV. Mural nodules in a PCN should not be considered an indisputable sign of pPCN invasiveness. © 2015 International Hepato-Pancreato-Biliary Association.

  15. Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?

    Energy Technology Data Exchange (ETDEWEB)

    Wenning, Christian; Rahbar, Kambiz; Schober, Otmar; Stegger, Lars [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); Vrachimis, Alexis; Schaefers, Michael [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); University of Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2013-07-15

    Coronary artery calcium scoring can complement myocardial perfusion imaging (MPI). The purpose of this study was to evaluate the feasibility and accuracy of using the CalciumScore-CT derived from a combined SPECT/CT device also for SPECT attenuation correction (AC). The study group comprised 99 patients who underwent both post-stress and rest MPI using a two-slice SPECT/CT system. For AC, one of the two scans was accompanied by a CalciumScore-CT scan (CalciumScore-CTAC) and the other by a conventional spiral CT (AttenCorr-CT) scan (AttenCorr-CTAC). In 48 patients the CalciumScore-CT scan was acquired with the post-stress scan and the AttenCorr-CT scan with the rest scan, and in 51 patients the order was reversed. The accuracy of the images based on AC was determined qualitatively by consensus reading with respect to the clinical diagnoses as well as quantitatively by comparing the perfusion summed stress scores (SSS) and the summed rest scores (SRS) between attenuation-corrected and uncorrected images. In comparison to the uncorrected images CalciumScore-CTAC led to regional inaccuracies in 14 of 51 of studies (27.5 %) versus 12 of 48 studies (25 %) with AttenCorr-CTAC for the stress studies and in 5 of 48 (10 %) versus 1 of 51 (2 %) for the rest studies, respectively. This led to intermediate and definite changes in the final diagnosis (ischaemia and/or scarring) in 12 % of the studies (12 of 99) and in 7 % of the studies (7 of 99) with CalciumScore-CTAC and in 9 % of the studies (9 of 99) and 4 % of the studies (4 of 99) with AttenCorr-CTAC. Differences in SSS and SRS with respect to the uncorrected images were greater for the CalciumScore-CTAC images than for the AttenCorr-CTAC images ({Delta}SSS 4.5 {+-} 5.6 and 2.1 {+-} 4.4, p = 0.023; {Delta}SRS 4.2 {+-} 4.9 and 1.6 {+-} 3.2, p = 0.004, respectively). Using the same CT scan for calcium scoring and SPECT AC is feasible. Image interpretation must, however, include uncorrected images since CT-based AC relatively

  16. Volumetric gain of the human pancreas after left partial pancreatic resection: A CT-scan based retrospective study.

    Science.gov (United States)

    Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana

    2015-01-01

    Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  17. Does head CT scan pathology predict outcome after mild traumatic brain injury?

    Science.gov (United States)

    Lannsjö, M; Backheden, M; Johansson, U; Af Geijerstam, J L; Borg, J

    2013-01-01

    More evidence is needed to forward our understanding of the key determinants of poor outcome after mild traumatic brain injury (MTBI). A large, prospective, national cohort of patients was studied to analyse the effect of head CT scan pathology on the outcome. One-thousand two-hundred and sixty-two patients with MTBI (Glasgow Coma Scale score 15) at 39 emergency departments completed a study protocol including acute head CT scan examination and follow-up by the Rivermead Post Concussion Symptoms Questionnaire and the Glasgow Outcome Scale Extended (GOSE) at 3 months after MTBI. Binary logistic regression was used for the assessment of prediction ability. In 751 men (60%) and 511 women (40%), with a mean age of 30 years (median 21, range 6-94), we observed relevant or suspect relevant pathologic findings on acute CT scan in 52 patients (4%). Patients aged below 30 years reported better outcome both with respect to symptoms and GOSE as compared to patients in older age groups. Men reported better outcome than women as regards symptoms (OR 0.64, CI 0.49-0.85 for ≥3 symptoms) and global function (OR 0.60, CI 0.39-0.92 for GOSE 1-6). Pathology on acute CT scan examination had no effect on self-reported symptoms or global function at 3 months after MTBI. Female gender and older age predicted a less favourable outcome. The findings support the view that other factors than brain injury deserve attention to minimize long-term complaints after MTBI. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  18. Prognostic value of preoperative intratumoral FDG uptake heterogeneity in patients with epithelial ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Maria; Kim, Hee Seung; Chung, Hyun Hoon; Kim, Jae-Weon; Park, Noh-Hyun; Song, Yong Sang [Seoul National University College of Medicine, Department of Obstetrics and Gynecology, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Hyunjong; Cheon, Gi Jeong [Seoul National University College of Medicine, Department of Nuclear Medicine, Cancer Research Institute, Seoul (Korea, Republic of)

    2017-01-15

    To investigate the prognostic value of intratumoral FDG uptake heterogeneity (IFH) derived from PET/CT in patients with epithelial ovarian cancer (EOC). We retrospectively reviewed patients with pathologically proven epithelial ovarian cancer who underwent preoperative {sup 18}F-FDG PET/CT scans. PET/CT parameters such as maximum and average standardized uptake values (SUV{sub max} and SUV{sub avg}), sum of all metabolic tumour volume (MTV), cumulative total lesion glycolysis (TLG) and IFH were assessed. Regression analyses were used to identify clinicopathological and imaging variables associated with disease-free survival (DFS). Clinicopathological data were reviewed for 61 eligible patients. The median duration of DFS was 13 months (range, 6-26 months), and 18 (29.5 %) patients experienced recurrence. High IFH values were associated with tumour recurrence (P = 0.005, hazard ratio 4.504, 95 % CI 1.572-12.902). The Kaplan-Meier survival graphs showed that DFS significantly differed in groups categorized based on IFH (P = 0.002, log-rank test). Moreover, there were significant differences in DFS (P = 0.009) and IFH (P = 0.040) between patients with and without recurrence. Preoperative IFH measured by {sup 18}F-FDG PET/CT was significantly associated with EOC recurrence. FDG-based heterogeneity could be a useful and potential predicator of EOC recurrence before treatment. (orig.)

  19. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    International Nuclear Information System (INIS)

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-01-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit

  20. Prognostic significance of standardized uptake value on preoperative 18F-FDG PET/CT in patients with ampullary adenocarcinoma

    International Nuclear Information System (INIS)

    Choi, Hye Jin; Kang, Chang Moo; Lee, Woo Jung; Jo, Kwanhyeong; Lee, Jong Doo; Lee, Jae-Hoon; Ryu, Young Hoon

    2015-01-01

    The purpose of this study was to investigate the prognostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with ampullary adenocarcinoma (AAC) after curative surgical resection. Fifty-two patients with AAC who had undergone 18 F-FDG PET/CT and subsequent curative resections were retrospectively enrolled. The maximum standardized uptake value (SUV max ) and tumor to background ratio (TBR) were measured on 18 F-FDG PET/CT in all patients. The prognostic significances of PET/CT parameters and clinicopathologic factors for recurrence-free survival (RFS) and overall survival (OS) were evaluated by univariate and multivariate analyses. Of the 52 patients, 19 (36.5 %) experienced tumor recurrence during the follow-up period and 18 (35.8 %) died. The 3-year RFS and OS were 62.3 and 61.5 %, respectively. Preoperative CA19-9 level, tumor differentiation, presence of lymph node metastasis, SUV max , and TBR were significant prognostic factors for both RFS and OS (p < 0.05) on univariate analyses, and patient age showed significance only for predicting RFS (p < 0.05). On multivariate analyses, SUV max and TBR were independent prognostic factors for RFS, and tumor differentiation, SUV max , and TBR were independent prognostic factors for OS. SUV max and TBR on preoperative 18 F-FDG PET/CT are independent prognostic factors for predicting RFS and OS in patients with AAC; patients with high SUV max (>4.80) or TBR (>1.75) had poor survival outcomes. The role of and indications for adjuvant therapy after curative resection of AAC are still unclear. 18 F-FDG uptake in the primary tumor could provide additive prognostic information for the decision-making process regarding adjuvant therapy. (orig.)

  1. Aquilion ONE / ViSION Edition CT scanner realizing 3D dynamic observation with low-dose scanning

    International Nuclear Information System (INIS)

    Kazama, Masahiro; Saito, Yasuo

    2015-01-01

    Computed tomography (CT) scanners have been continuously advancing as essential diagnostic imaging equipment for the diagnosis and treatment of a variety of diseases, including the three major disease classes of cerebrovascular disease, cardiovascular disease, and cancer. Through the development of helical CT scanners and multislice CT scanners, Toshiba Medical Systems Corporation has developed the Aquilion ONE, a CT scanner with a scanning range of up to 160 mm per rotation that can obtain three-dimensional (3D) images of the brain, heart, and other organs in a single rotation. We have now developed the Aquilion ONE / ViSION Edition, a next-generation 320-row multislice CT scanner incorporating the latest technologies that achieves a shorter scanning time and significant reduction in dose compared with conventional products. This product with its low-dose scanning technology will contribute to the practical realization of new diagnosis and treatment modalities employing four-dimensional (4D) data based on 3D dynamic observations through continuous rotations. (author)

  2. Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT

    International Nuclear Information System (INIS)

    Johnston, Jennifer H.; Podberesky, Daniel J.; Larson, David B.; Alsip, Christopher; Yoshizumi, Terry T.; Angel, Erin; Barelli, Alessandra; Toncheva, Greta; Egelhoff, John C.; Anderson-Evans, Colin; Nguyen, Giao B.; Frush, Donald P.; Salisbury, Shelia R.

    2013-01-01

    Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting. (orig.)

  3. Use of 18F-FDG PET/CT in the preoperative evaluation of patients diagnosed with peritoneal carcinomatosis of ovarian origin, candidates to cytoreduction and hipec. A pending issue

    International Nuclear Information System (INIS)

    Lopez-Lopez, V.; Cascales-Campos, P.A.; Gil, J.; Frutos, L.; Andrade, R.J.; Fuster-Quiñonero, M.; Feliciangeli, E.; Gil, E.; Parrilla, P.

    2016-01-01

    Highlights: • CT showed the better results confirming ovarian peritoneal disease than 18 F-FDG PET/CT. • CT and 18 F-FDG PET/CT present a low detection capability for LSS-3 injury. • Main utility of 18 F-FDG PET/CT is the evaluation of extraperitoneal extension. - Abstract: Purpose: To evaluate the clinical usefulness of the results obtained with 18 F-FDG PET/CT in relation to CT in the preoperative staging of patients with peritoneal carcinomatosis secondary to primary or recurrent ovarian cancer candidates to cytoreductive surgery and hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC). Material and methods: A retrospective study comparing the results obtained with CT and 18 F-FDG PET/CT in the preoperative evaluation of a series of 59 patients was performed. In all patients the peritoneal carcinomatosis index (PCI) was determined by preoperative radiological CT and 18F-FDG PET/CT and compared with surgical PCI, which was considered as reference. Results: Of the 59 patients studied, in 55 peritoneal carcinomatosis presences were confirmed (4 patients had complete responses to neoadjuvant chemotherapy). The mean surgical, CT and 18F-FDG PET/CT PCI was 9.46 ± 7.70, 3.69 ± 3.96 and 2.25 ± 1.02, respectively. In the global disease detection, CT showed a higher positive likelihood ratio (LR+) than 18 F-FDG PET/CT (15.3, 95% CI 8.35–28.04 vs. 3.47, 95% CI 3.36–5.11) and a lower negative likelihood ratio (LR-) than 18F-FDG PET/CT (0.67, 95% CI 0.61–0.73 vs. 0.82, 95% CI 0.76–0.88). In every region of the abdomen the CT showed a greater LR+ than 18F-FDG PET/CT and a lower LR- than 18F-FDG PET/CT. Conclusions: CT showed the best diagnostic results compared to 18 F-FDG PET/CT to confirme the presence of peritoneal disease. The lower performance of the 18 F-FDG PET/CT suggests that the main utility of 18 F-FDG PET/CT is to evaluate a possible metastatic extraperitoneal spread of the disease.

  4. Automated volumetry of temporal horn of lateral ventricle for detection of Alzheimer's disease in CT scan

    Science.gov (United States)

    Takahashi, Noriyuki; Kinoshita, Toshibumi; Ohmura, Tomomi; Matsuyama, Eri; Toyoshima, Hideto

    2018-02-01

    The rapid increase in the incidence of Alzheimer's disease (AD) has become a critical issue in low and middle income countries. In general, MR imaging has become sufficiently suitable in clinical situations, while CT scan might be uncommonly used in the diagnosis of AD due to its low contrast between brain tissues. However, in those countries, CT scan, which is less costly and readily available, will be desired to become useful for the diagnosis of AD. For CT scan, the enlargement of the temporal horn of the lateral ventricle (THLV) is one of few findings for the diagnosis of AD. In this paper, we present an automated volumetry of THLV with segmentation based on Bayes' rule on CT images. In our method, first, all CT data sets are normalized into an atlas by using linear affine transformation and non-linear wrapping techniques. Next, a probability map of THLV is constructed in the normalized data. Then, THLV regions are extracted based on Bayes' rule. Finally, the volume of the THLV is evaluated. This scheme was applied to CT scans from 20 AD patients and 20 controls to evaluate the performance of the method for detecting AD. The estimated THLV volume was markedly increased in the AD group compared with the controls (P < .0001), and the area under the receiver operating characteristic curve (AUC) was 0.921. Therefore, this computerized method may have the potential to accurately detect AD on CT images.

  5. Role of multislice CT and magnetic resonance cholangiography in preoperative evaluation of potential donor in living related liver transplantation

    Directory of Open Access Journals (Sweden)

    Hossam M. Abdel-Rahman

    2016-03-01

    Conclusion: Multislice CT is a valuable tool in the evaluation of potential living liver donors that provides complete information on the hepatic vascular anatomy, the liver parenchyma, and volumetric measurements. MRC with a 3.0-T MR system demonstrates the preoperative biliary evaluation very well with a high accuracy rate.

  6. Extensive Tattoos Mimicking Lymphatic Metastasis on Positron Emission Tomography Scan in a Patient With Cervical Cancer.

    Science.gov (United States)

    Grove, Narine; Zheng, Ma; Bristow, Robert E; Eskander, Ramez N

    2015-07-01

    Positron emission tomography (PET) fused with computed tomography (CT) imaging is common in the clinical assessment of patients with locally advanced cervical cancer. Limitations to the utilization and interpretation of PET-CT scans in patients with cervical cancer have been described, including false-positive findings secondary to tattoo ink. A 32-year-old woman presented with clinical stage 1B1 cervical cancer and extensive tattoos of the lower extremities. Preoperative PET-CT scan identified two ileac lymph nodes with increased fluorine-18-deoxyglucose uptake suspicious for metastatic disease. At the time of surgical resection, bilateral pigmented lymph nodes were identified with histologic examination showing deposition of tattoo ink and no malignant cells. Physicians should be cognizant of the possible effects of tattoos on PET-CT findings while counseling patients and formulating a treatment program.

  7. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    International Nuclear Information System (INIS)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease. (author)

  8. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease.

  9. Preoperative cardiac computed tomography for demonstration of congenital cardiac septal defect in adults

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Hye-Joung; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan [University of Ulsan College of Medicine, Department of Cardiology and Heart Institute, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won [University of Ulsan College of Medicine, Department of Cardiothoracic surgery, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of)

    2015-06-01

    We aimed to evaluate the role of preoperative cardiac computed tomography (CT) for adults with congenital cardiac septal defect (CSD). Sixty-five consecutive patients who underwent preoperative CT and surgery for CSD were included. The diagnostic accuracy of CT and the concordance rate of the subtype classification of CSD were evaluated using surgical findings as the reference standard. Sixty-five patients without CSD who underwent cardiac valve surgery were used as a control group. An incremental value of CT over echocardiography was described retrospectively. Sensitivity and specificity of CT for diagnosis of CSD were 95 % and 100 %, respectively. The concordance rate of subtype classification was 91 % in CT and 92 % in echocardiography. The maximum size of the defect measured by CT correlated well with surgical measurement (r = 0.82), and the limit of agreement was -0.9 ± 7.42 mm. In comparison with echocardiography, CT was able to detect combined abnormalities in three cases, and exclusively provided correct subtype classification or clarified suspected abnormal findings found on echocardiography in seven cases. Cardiac CT can accurately demonstrates CSD in preoperative adult patients. CT may have an incremental role in preoperative planning, particularly in those with more complex anatomy. (orig.)

  10. CT findings of tuberculous lymphadenifis in parotid gland

    International Nuclear Information System (INIS)

    Wang Changfu; Wang Binjie; Zhang Heping; Jin Haiying; Nie Peng; Chang Liang; Wei Haigang; Zou Ling

    2008-01-01

    Objective: To analyze the CT findings of tuberculous lymphadenitis in parotid gland, so as to improve the diagnostic accuracy of tuberculosis of parotid gland. Methods: Nine cases with tuberculous lymphadenitis in parotid gland confirmed by surgical pathology and acid-fast bacilli after preoperative spiral CT plain scan and two phases dynamic enhancement scan were retrospectively analyzed. Imaging findings of CT were reviewed and compared with surgical pathology. Results: Seven of the 9 cases of tuberculosis of the parotid gland occurred in the left side, and 2 in the right side, and superficial lobe involvement occurred in 8 cases and deep lobe in 1 case. The lesion was classified as tumour type (8 cases) and infiltration type (1 case). In turnout type, the number of lesion was from 1 to 4, and the size was from 2.7 to 5.3 cm in diameter. One case of infiltration type measured 3.4 cm in diameter. On CT plain scan, the lesions showed homogeneous slight high-density with regular edge in 5 cases and irregular low-density in 4 cases, and 2 of them with partly blurred edge. On CT enhanced scan, uniform moderate enhancement was seen in 3 cases, circular enhancement in 4 cases, inhomogeneous enhancement in 1 case, and lace-like enhancement in 1 case. Local infiltration occurred in 6 cases. Lymphadenovarix in the same side of lesion occurred in 2 cases. Conclusion: CT findings of tuberculous lymphadenitis in parotid gland present diversification, which correlate well with pathological changes. Understanding of characteristic CT findings of tuberculous lymphadenitis in parotid gland is helpful for differential diagnosis, but final diagnosis still depends on pathology and acid-fast bacilli. (authors)

  11. Study of effect of different CT scanning protocols on HU variation and their impact on TPS calculations

    International Nuclear Information System (INIS)

    Mahur, Mamta; Sharma, Richa; Sasindaran, M.; Singh, Anshu; Gedam, Varsha; Negi, P.S.; Grover, R.K.

    2016-01-01

    Computer tomographic (CT) scans are used to correct for tissue inhomogeneties in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and relative electron densities, which is the basic input for radiotherapy planning systems which consider tissue heterogeneities. The purpose of this study is to investigate the influence of different CT scan parameters (kVp, mAs) on uniformity of CT numbers versus relative electron density (HURED) curves and their different dosimetric impact

  12. Differences in MRI findings in cases showing ring-enhancement on a CT scan

    International Nuclear Information System (INIS)

    Tokiwa, Kaichi; Hashimoto, Takashi; Miyasaka, Yoshio; Yada, Kenzoh; Kan, Shinichi; Takagi, Hiroshi.

    1990-01-01

    It is sometimes difficult to differentiate between a brain abscess and a tumor, for both show ring-enhancement on a CT scan. The present authors have studied the benefit of MRI for the differential diagnosis of these two lesions. The subjects of this study were 6 cases of brain abscess and 10 cases of brain tumor, all of them showing ring-enhancement on a CT scan. The MRI findings were compared with those of the CT scan taken at almost the same time, especially focussing on the difference in the ring-enhancement. In 5 out of the 6 cases of brain abscess, T 2 -weighted MRI demonstrated a comparatively thin and homogeneous low-intensity, round rim. In the cases of brain tumor, however, none of the cases demonstrated this typical low-intensity, round rim; rather, in them the rim was thick and irregular. The authors can conclude that those MRI findings can serve as important differential diagnostic findings between brain abscess and tumor; also, MRI may be used as a landmark for terminating the administration of antibiotics in cases of brain abscess. (author)

  13. Clinical study of acute cerebral infarction with a midline shift on the CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takemae, T; Mizukami, M; Kin, H; Kawase, T; Araki, G [Mihara Memorial Hospital, Isezaki, Gunma (Japan)

    1978-12-01

    Twenty-one cases of acute cerebral infarction with a midline shift on the CT scan were studied with respect to the development of the midline shift, the angiographic findings, the clinical pictures and the outcome of these patients. The CT findings of hemorrhagic infarction were also studied. No cases showed a midline shift on a CT scan taken within 6 hours after the onset. A midline shift was, however, noted as early as 9 hours after the onset, and it reached its peak between the 2nd and 7th day of the onset. It gradually disappeared by the end of the third week. Hemorrhagic infarction was diagnosed in 6 patients by either spinal tap or autopsy. The CT findings of these hemorrhagic infarction were divided into two types, solid hemorrhages with an unequivocal high density within the low-density area, and small, scattered hemorrhagic of almost the same density as normal brain tissue within the low-density area. In 19 of 21 patients, an round-edged occlusion and/or embolus were observed on the initial angiograms. The recanalization of the occluded vessels was proved in 10 of 14 patients by subsequent angiographic studies. Twenty of 21 patients showed a sudden development of neurological symptoms, and 15 patients had a history of various kinds of heart disease, such as atrial fibrillation, valvular heart disease and myocardial infarction. The patients had atrial fibrillation on EKG on admission. These angiographic findings and clinical pictures strongly suggest that the infarction with a midline shift on the CT scan may be caused by a cerebral embolism of cardiac origin. Eight patients died of cerebral herniation between the 2nd and 6th day of the onset. Taking these poor outcomes into consideration, surgical as well as medical decompression of the brain would seem to be most important when the CT scan shows a midline shift.

  14. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  15. A coarse-to-fine approach for pericardial effusion localization and segmentation in chest CT scans

    Science.gov (United States)

    Liu, Jiamin; Chellamuthu, Karthik; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald M.

    2018-02-01

    Pericardial effusion on CT scans demonstrates very high shape and volume variability and very low contrast to adjacent structures. This inhibits traditional automated segmentation methods from achieving high accuracies. Deep neural networks have been widely used for image segmentation in CT scans. In this work, we present a two-stage method for pericardial effusion localization and segmentation. For the first step, we localize the pericardial area from the entire CT volume, providing a reliable bounding box for the more refined segmentation step. A coarse-scaled holistically-nested convolutional networks (HNN) model is trained on entire CT volume. The resulting HNN per-pixel probability maps are then threshold to produce a bounding box covering the pericardial area. For the second step, a fine-scaled HNN model is trained only on the bounding box region for effusion segmentation to reduce the background distraction. Quantitative evaluation is performed on a dataset of 25 CT scans of patient (1206 images) with pericardial effusion. The segmentation accuracy of our two-stage method, measured by Dice Similarity Coefficient (DSC), is 75.59+/-12.04%, which is significantly better than the segmentation accuracy (62.74+/-15.20%) of only using the coarse-scaled HNN model.

  16. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  17. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  18. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  19. Assessment value of quantitative indexes of pancreatic CT perfusion scanning for malignant degree of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Jiang-Xia Lei

    2016-10-01

    Full Text Available Objective: To analyze the assessment value of the quantitative indexes of pancreatic CT perfusion scanning for malignant degree of pancreatic cancer. Methods: A total of 58 patients with space-occupying pancreatic lesions were divided into 20 patients with pancreatic cancer and 38 patients with benign pancreatic lesions after pancreatic CT perfusion. Patients with pancreatic cancer received palliative surgery, and the cancer tissue and para-carcinoma tissue specimens were collected during operation. The differences in pancreatic CT perfusion scanning parameter values and serum tumor marker levels were compared between patients with pancreatic cancer and patients with benign pancreatic lesions, mRNA expression levels of malignant molecules in pancreatic cancer tissue and para-carcinoma tissue were further determined, and the correlation between pancreatic CT perfusion scanning parameter values and malignant degree of pancreatic cancer was analyzed. Results: CT perfusion scanning BF, BV and Per values of patients with pancreatic cancer were lower than those of patients with benign pancreatic lesions; serum CA19-9, CEA, CA125 and CA242 levels were higher than those of patients with benign pancreatic lesions (P<0.05; mRNA expression levels of Bcl-2, Bcl-xL and survivin in pancreatic cancer tissue samples were higher than those in paracarcinoma tissue samples, and mRNA expression levels of P53 and Bax were lower than those in para-carcinoma tissue samples (P<0.05; CT perfusion scanning parameters BF, BV and Per values of patients with pancreatic cancer were negatively correlated with CA19-9, CEA, CA125 and CA242 levels in serum as well as mRNA expression levels of Bcl-2, Bcl-xL and survivin in pancreatic cancer tissue, and positively correlated with mRNA expression levels of P53 and Bax in pancreatic cancer tissue (P<0.05. Conclusions: Pancreatic CT perfusion scanning is a reliable way to judge the malignant degree of pancreatic cancer and plays a

  20. Community-Acquired Pneumonia Visualized on CT Scans but Not Chest Radiographs: Pathogens, Severity, and Clinical Outcomes.

    Science.gov (United States)

    Upchurch, Cameron P; Grijalva, Carlos G; Wunderink, Richard G; Williams, Derek J; Waterer, Grant W; Anderson, Evan J; Zhu, Yuwei; Hart, Eric M; Carroll, Frank; Bramley, Anna M; Jain, Seema; Edwards, Kathryn M; Self, Wesley H

    2018-03-01

    The clinical significance of pneumonia visualized on CT scan in the setting of a normal chest radiograph is uncertain. In a multicenter prospective surveillance study of adults hospitalized with community-acquired pneumonia (CAP), we compared the presenting clinical features, pathogens present, and outcomes of patients with pneumonia visualized on a CT scan but not on a concurrent chest radiograph (CT-only pneumonia) and those with pneumonia visualized on a chest radiograph. All patients underwent chest radiography; the decision to obtain CT imaging was determined by the treating clinicians. Chest radiographs and CT images were interpreted by study-dedicated thoracic radiologists blinded to the clinical data. The study population included 2,251 adults with CAP; 2,185 patients (97%) had pneumonia visualized on chest radiography, whereas 66 patients (3%) had pneumonia visualized on CT scan but not on concurrent chest radiography. Overall, these patients with CT-only pneumonia had a clinical profile similar to those with pneumonia visualized on chest radiography, including comorbidities, vital signs, hospital length of stay, prevalence of viral (30% vs 26%) and bacterial (12% vs 14%) pathogens, ICU admission (23% vs 21%), use of mechanical ventilation (6% vs 5%), septic shock (5% vs 4%), and inhospital mortality (0 vs 2%). Adults hospitalized with CAP who had radiological evidence of pneumonia on CT scan but not on concurrent chest radiograph had pathogens, disease severity, and outcomes similar to patients who had signs of pneumonia on chest radiography. These findings support using the same management principles for patients with CT-only pneumonia and those with pneumonia seen on chest radiography. Copyright © 2017 American College of Chest Physicians. All rights reserved.

  1. Dose reduction for CT in children with cystic fibrosis: is it feasible to reduce the number of images per scan?

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Tiddens, Harm A.W.M.; Nakano, Yasutaka; Lequin, Maarten H.

    2006-01-01

    Reducing the dose for each CT scan is important for children with cystic fibrosis (CF). To determine whether the number of CT images and therefore the dose per CT scan could be reduced without any significant loss of information in children with CF. A cohort of children with CF was followed with biennial surveillance CT scans, obtained in inspiration after a voluntary breath-hold as 1-mm thick images at 10-mm intervals from lung apex to base. A random set of 20 baseline CT scans and 10 follow-up CT scans were blinded. Sets of every image (10-mm intervals), every second image (20-mm intervals), every third image (30-mm intervals) and a selection of three and five images were scored randomly using a published CT scoring system by one experienced observer. The 20 subjects were 10 years of age with a range of 3.7-17.6 years at baseline. Fewer CT images resulted in a significantly lower (less abnormal) CT score and the number of patients positive for abnormalities decreased subsequently. At intervals greater than 20 mm no significant change in CT score over 2 years could be detected, while the CT scores at 10-mm (P=0.02) and 20-mm (P=0.02) intervals worsened significantly. A reduction in the number of inspiratory CT images by increasing the interval between images to greater than 10 mm is not a valid option for radiation dose reduction in children with CF. (orig.)

  2. Automated Agatston score computation in non-ECG gated CT scans using deep learning

    Science.gov (United States)

    Cano-Espinosa, Carlos; González, Germán.; Washko, George R.; Cazorla, Miguel; San José Estépar, Raúl

    2018-03-01

    Introduction: The Agatston score is a well-established metric of cardiovascular disease related to clinical outcomes. It is computed from CT scans by a) measuring the volume and intensity of the atherosclerotic plaques and b) aggregating such information in an index. Objective: To generate a convolutional neural network that inputs a non-contrast chest CT scan and outputs the Agatston score associated with it directly, without a prior segmentation of Coronary Artery Calcifications (CAC). Materials and methods: We use a database of 5973 non-contrast non-ECG gated chest CT scans where the Agatston score has been manually computed. The heart of each scan is cropped automatically using an object detector. The database is split in 4973 cases for training and 1000 for testing. We train a 3D deep convolutional neural network to regress the Agatston score directly from the extracted hearts. Results: The proposed method yields a Pearson correlation coefficient of r = 0.93; p <= 0.0001 against manual reference standard in the 1000 test cases. It further stratifies correctly 72.6% of the cases with respect to standard risk groups. This compares to more complex state-of-the-art methods based on prior segmentations of the CACs, which achieve r = 0.94 in ECG-gated pulmonary CT. Conclusions: A convolutional neural network can regress the Agatston score from the image of the heart directly, without a prior segmentation of the CACs. This is a new and simpler paradigm in the Agatston score computation that yields similar results to the state-of-the-art literature.

  3. Evaluation of variation of voltage (kV) absorbed dose in chest CT scans

    International Nuclear Information System (INIS)

    Mendonca, Bruna G.A.; Mourao, Arnaldo P.

    2013-01-01

    Computed tomography (CT) is one of the most important diagnostic techniques images today. The increasing utilization of CT implies a significant increase of population exposure to ionizing radiation. Optimization of practice aims to reduce doses to patients because the image quality is directly related to the diagnosis. You can decrease the amount of dose to the patient, and maintain the quality of the image. There are several parameters that can be manipulated in a CT scan and these parameters can be used to reduce the energy deposited in the patient. Based on this, we analyzed the variation of dose deposited in the lungs, breasts and thyroid, by varying the supply voltage of the tube. Scans of the thorax were performed following the protocol of routine chest with constant and variable current for the same applied voltage. Moreover, a female phantom was used and thermoluminescent dosimeters (TLD-100), model bat, were used to record the specific organ doses. Scans were performed on a GE CT scanner, model 64 Discovery channels. Higher doses were recorded for the voltage of 120 kV with 200 mAs in the lungs (22.46 mGy) and thyroid (32.22 mGy). For scans with automatic mAs, variable between 100 and 440, this same tension contributed to the higher doses. The best examination in terms of the dose that was used with automatic 80 kV mAs, whose lungs and thyroid received lower dose. For the best breast exam was 100 kV. Since the increase in the 80 kV to 100 kV no impact so much the dose deposited in the lungs, it can be concluded that lowering the applied voltage to 100 kV resulted in a reduction in the dose absorbed by the patient. These results can contribute to optimizing scans of the chest computed tomography

  4. Automatic calibration method of voxel size for cone-beam 3D-CT scanning system

    International Nuclear Information System (INIS)

    Yang Min; Wang Xiaolong; Wei Dongbo; Liu Yipeng; Meng Fanyong; Li Xingdong; Liu Wenli

    2014-01-01

    For a cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary stage along X-ray direction. In order to realize the automatic calibration of the voxel size, a new and easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least-square fitting. Through these interpolation values, a linear equation is obtained that reflects the relationship between the voxel size and the rotary stage translation distance from its nominal zero position. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system. When the rotary stage is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy. (authors)

  5. Lecithin-coated gold nanoflowers (GNFs) for CT scan imaging applications and biochemical parameters; in vitro and in vivo studies.

    Science.gov (United States)

    Aziz, Farooq; Bano, Khizra; Siddique, Ahmad Hassan; Bajwa, Sadia Zafar; Nazir, Aalia; Munawar, Anam; Shaheen, Ayesha; Saeed, Madiha; Afzal, Muhammad; Iqbal, M Zubair; Wu, Aiguo; Khan, Waheed S

    2018-01-09

    We report a novel strategy for the fabrication of lecithin-coated gold nanoflowers (GNFs) via single-step design for CT imaging application. Field-emission electron microscope confirmed flowers like morphology of the as-synthesized nanostructures. Furthermore, these show absorption peak in near-infrared (NIR) region at λ max 690 nm Different concentrations of GNFs are tested as a contrast agent in CT scans at tube voltage 135 kV and tube current 350 mA. These results are compared with same amount of iodine at same CT scan parameters. The results of in vitro CT scan study show that GNFs have good contrast enhancement properties, whereas in vivo study of rabbits CT scan shows that GNFs enhance the CT image clearly at 135 kV as compared to that of iodine. Cytotoxicity was studied and blood profile show minor increase of white blood cells and haemoglobin, whereas decrease of red blood cells and platelets.

  6. Comparative evaluation of coronal images of the middle ear visualized by CT scan and polytomography

    International Nuclear Information System (INIS)

    Sugiyama, Masao; Nakai, Yoshiaki; Cho, Kansei; Tanabe, Kyoji; Inoue, Yuichi; Onoyama, Yasuto

    1982-01-01

    We retrospectively analysed the coronal images of the middle ear obtained by multidirectional tomography (polytomography) and computed tomography (CT) in 40 patients. Although CT was capable of demonstrating water density in the middle ear more clearly than polytomography and of delineating a lesion extending even outside of the petrous bone, the diagnostic capability was not much different between the two tomographic techniques. On the other hand, coronal CT scan has a disadvantage in that it usually has to be performed during hyperextension of the neck or while patients are in an uncomfortable hanging head position. We think that CT scan should be utilized only in case with a lesion extending beyond the petrous bone and/or is not well visualized by polytomography. (author)

  7. Evaluation of the image quality of chest CT scans: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Martins N, P. I.; Prata M, A., E-mail: priscillainglid@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  8. Evaluation of the image quality of chest CT scans: a phantom study

    International Nuclear Information System (INIS)

    Martins N, P. I.; Prata M, A.

    2016-10-01

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  9. Detection of lacunar infarction in brain CT-scans: No evidence of bias from accompanying patient information

    International Nuclear Information System (INIS)

    Bonke, B.; Knippenberg, F.C.E. van; Duivenvoorden, H.J.; Kappelle, L.J.

    1989-01-01

    Interobserver agreement in assessing brain CT-scans is, in general, high. The extent, however, to which such agreement is caused by bias through knowledge of other clinical details remains uncertain. The hypothesis that observers are somehow prejudiced before assessing ambiguous, CT-scans in this particular situation was tested. Sixteen neurologists and 16 radiologists volunteered to interpret two ambiguous brain CT-scans, with regard to the presence or absence of a lacunar infarct in the region of the internal capsule. The scans were accompanied by 'patient' information that was or was not suggestive of a stroke. These scans were camouflaged by a variety of other scans, to be assessed in the same way, to mask the purpose of the study. I was assumed that the observers, in their assessments of the scans, would somehow let their ratings of the likelihood of a lacunar infarction in or near the internal capsule be subject to the accompanying information. Results showed lower ratings produced by neurologists (i.e., less likelihood of an infarction) than by radiologists in the majority of all assessments, but no bias by the accompanying information. (orig.)

  10. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  11. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  12. Value of whole body bone scan in the pre-operative assessment in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, P [Oerebro Regional Hospital (Sweden). Dept. of Oncology; Vikterloef, K J; Beckman, K W [Oerebro Regional Hospital (Sweden). Dept. of Radiation Physics; Rydman, H; Blom, O [Oerebro Regional Hospital (Sweden). Dept. of Diagnostic Radiology

    1979-01-01

    In 126 patients with primary breast cancer a patient moving whole-body bone scan was performed when they first presented. None of the patients in stage I had an evidence of skeletal metastases. Two patients (3%) of 62 in stage II and 4 patients (17%) in stage III had evidence of skeletal metastases. It appears that whole-body scanning is the most accurate, sensitive and convenient method of detecting osseous metastases and of staging breast cancer. This investigation should be carried out pre-operatively. Detection of early asymptomatic bony metastases will provide a better planning of treatment with rational approach.

  13. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  14. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  15. A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.

    Science.gov (United States)

    Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim

    2009-04-07

    Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.

  16. Clinical efficacy of FDG-PET scan as preoperative diagnostic tool in cervical cancer stage Ib and IIa: comparison between the results of FDG-PET scan and operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Hoon

    1999-12-01

    This study was done to evaluate the clinical feasibility of FDG-PET scan for routine preoperative diagnostic methods in cervical carcinoma. PET-scans were performed from March, 1999 to November, 1999. There were 6 stage Ib and 7 IIa patients and all patients were performed radical hysterectomy and bilateral pelvic lymph node dissections and were evaluated by FDG-PET scan before operation. The mean age of the patients were 50.3 years old. Six cases had lymph node metastases by pelvis MRI, and three cases by FDG-PET scan. We could not find any lymph node metastases at surgery in 3 patients (50.0%) among 6 patients who were diagnosed by nodal metastases by pelvis MRI. And we found 1 patients with nodal metastases who had negative findings by pelvis MRI. By FDG-PET scan, we could find metastases in all positive patients. But we also found 2 additional metastatic cases in the patients with negative findings. In this study, the comparison was very difficult due to the individual differences in the comparison would be made by site-specific not person. The sensitivity of MRI and FDG-PET scan were 50.0% and 30.0%. The specificity were 94.1 % and 95.6%. The positive predictive value were 55.6 % and 50.0 %. In conclusion, we could find any superiority of FDG-PET scan in the diagnosis of lymph node metastases the pelvis MRI. So there are limitations to use the FDG-PET scan in the routine preoperative diagnostic tools in cervical cancer. But if we have more experiences to use the FDG-PET scan such as precise cut-off value of SUV and combination of other imaging technique, the FDG-PET scan are still promising diagnostic tools in cervical cancer.

  17. F-18-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections.

  18. Computed tomographic (CT) scans in cerebral palsy (CP)

    International Nuclear Information System (INIS)

    Kolawole, T.M.; Patel, P.J.; Mahdi, A.H.

    1989-01-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.)

  19. Application of dual-energy scanning technique with dual-source CT in pulmonary mass lesions

    International Nuclear Information System (INIS)

    Jiang Jie; Xu Yiming; He Bo; Xie Xiaojie; Han Dan

    2012-01-01

    Objective: To explore the feasibility of DSCT dual-energy technique in pulmonary mass lesions. Methods: A total of 100 patients with pulmonary masses underwent conventional plain CT scan and dual-energy enhanced CT scan. The virtual non-contrast (VNC) images were obtained at post-processing workstation.The mean CT value,enhancement value,signal to noise ratio (SNR), image quality and radiation dose of pulmonary masses were compared between the two scan techniques using F or t test and the detectability of lesions was compared using Wilcoxon test. Results: There was no statistically significant difference among VNC (A) (32.89 ± 12.58) HU,VNC (S) (30.86 ± 9.60) HU and conventional plain images (35.89 ± 9.99) HU in mean CT value of mass (F =2.08, P>0.05). There was statistically significant difference among VNC (A) (3.29 ± 1.45), VNC (S) (3.93 ± 1.49) and conventional plain image (4.61 ± 1.50) in SNR (F =6.01, P<0.05), which of conventional plain scan was higher than that of VNC.The enhancement value of mass in conventional enhanced scan (60.74 ± 13.9) HU and distribution of iodine from VNC (A) (58.26 ± 31.99) HU was no statistically significant difference (t=0.48, P>0.05), but there was a significant difference between conventional enhanced scan (56.51 ± 17.94) HU and distribution of iodine from VNC (S) (52.65 ± 16.78) HU (t=4.45, P<0.05). There was no statistically significant difference among conventional plain scan (4.69 ± 0.06) and VNC (A) (4.60 ± 0.09), VNC (S) (4.61 ±0.11) in image quality at mediastinal window (F=3.014, P>0.05). The appearance, size, internal features of mass (such as necrosis, calcification and cavity) were showed the same in conventional plain scan, VNC (A) and VNC (S). Of 41 patients with hilar mass, 18 patients were found to have lobular and segmental perfusion decrease or defect. Perfusion defect area was found in 59 patients with peripheral lung mass. The radiation dose of dual-energy enhanced scan was lower than that of

  20. Is direct radiologist supervision of abdominal computed tomography (CT) scans necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Goh, V. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Halligan, S. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)]. E-mail: s.halligan@imperial.ac.uk; Anderson, J.M. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Hugill, J. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Leonard, A. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)

    2005-07-01

    AIM: To determine the effect of direct radiological supervision of patients attending for abdominal CT by assessing the frequency of protocol alteration subsequent to radiologist review of the images obtained. MATERIALS AND METHODS: A prospective questionnaire-based observational study was performed of 187 consecutive patients undergoing abdominal CT. The CT protocol was determined by a radiologist in advance, with reference to the request form. Any subsequent change in the prescribed study that was contingent on radiologist review of the images obtained was documented on the questionnaire. Comparison was made with a second (control) group of 100 patients undergoing cranial CT. RESULTS: A protocol change was undertaken following radiologist review of the CT images of 17 (9%) of the group undergoing abdominal CT, compared with 14 (14%) of the group undergoing cranial CT. In the abdominal CT group, further scanning was performed for lesion characterization, to guide a subsequent interventional procedure, because of inadequate anatomical coverage or to evaluate an unexpected lung tumour. There was no significant difference in proportions between the two groups (p=0.23). CONCLUSION: When abdominal and cranial CT studies were compared, there was no significant difference in the proportion of studies requiring a change in the prescribed protocol following radiologist review of the images obtained. There was no evidence to suggest that abdominal CT was any less suited to protocol.

  1. Bone scan and SPECT/CT findings in marble bone disease

    International Nuclear Information System (INIS)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram

    2012-01-01

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ( 99m Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  2. Bone scan and SPECT/CT findings in marble bone disease

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram [Jaslok Hospital and Research Centre, Woril (India)

    2012-03-15

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ({sup 99m}Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  3. Radiation dose reduction at a price: the effectiveness of a thyroid shield during head CT scanning

    International Nuclear Information System (INIS)

    Fu Qiang; Lu Tao; Zhang Ling

    2008-01-01

    Objective: To assess radiation dose to the thyroid in patients undergoing head CT scanning and to evaluate dose reduction to the thyroid by load shielding. Methods: A post-morterm was scanned by different model and study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. (a)No thyroid shields and (b) thyroid shield. One thermoluminescent dosimeters (TLDs)were placed over the thyroid gland center, A thyroid lead shield (Pb eq 0.5mm)was placed around the neck of post-morterm. Scan parameter, CTDIw and DLP were recorded. Results: (a) 0.207mSv; (b) 0.085mSv. A mean effective radiation dose reduction of 58% was seen in the shielded versus the unshielded. Conclusion: Thyroid exposure to scattered radiation from head CT scanning only once is associated with a low but not negligible risk of cancer, but accumulatived doses to the thyroid are serious, highlighting the need for increased awareness of patient radiation protection. Thyroid lead shielding yields significant radiation protection, which should be used routinely during head CT scan. (authors)

  4. Optimal CT scanning parameters for commonly used tumor ablation applicators

    International Nuclear Information System (INIS)

    Eltorai, Adam E.M.; Baird, Grayson L.; Monu, Nicholas; Wolf, Farrah; Seidler, Michael; Collins, Scott; Kim, Jeomsoon; Dupuy, Damian E.

    2017-01-01

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  5. Optimal CT scanning parameters for commonly used tumor ablation applicators

    Energy Technology Data Exchange (ETDEWEB)

    Eltorai, Adam E.M. [Warren Alpert Medical School of Brown University (United States); Baird, Grayson L. [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Lifespan Biostatistics Core (United States); Rhode Island Hospital (United States); Monu, Nicholas; Wolf, Farrah; Seidler, Michael [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States); Collins, Scott [Department of Diagnostic Imaging (United States); Rhode Island Hospital (United States); Kim, Jeomsoon [Department of Medical Physics (United States); Rhode Island Hospital (United States); Dupuy, Damian E., E-mail: ddupuy@comcast.net [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States)

    2017-04-15

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  6. Nodule detection methods using autocorrelation features on 3D chest CT scans

    International Nuclear Information System (INIS)

    Hara, T.; Zhou, X.; Okura, S.; Fujita, H.; Kiryu, T.; Hoshi, H.

    2007-01-01

    Lung cancer screening using low dose X-ray CT scan has been an acceptable examination to detect cancers at early stage. We have been developing an automated detection scheme for lung nodules on CT scan by using second-order autocorrelation features and the initial performance for small nodules (< 10 mm) shows a high true-positive rate with less than four false-positive marks per case. In this study, an open database of lung images, LIDC (Lung Image Database Consortium), was employed to evaluate our detection scheme as an consistency test. The detection performance for solid and solitary nodules in LIDC, included in the first data set opened by the consortium, was 83% (10/12) true-positive rate with 3.3 false-positive marks per case. (orig.)

  7. Role of mediastinal and multi-organ CT scans in staging presumable surgical candidates with non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hiroaki; Nakajima, Yasuo; Taira, Yasuhiko; Yokote, Kumio; Noguchi, Teruhiko

    1987-09-01

    In order to evaluate the role of CT scan and bone scan in staging patients with non-small-cell lung cancer presumably indicated for surgery, 70 consecutive patients who underwent thoracotomy were reviewed. Most of them received mediastinal and multi-organ (brain, liver and adrenal) CT scans and a bone scan. In the most recent 40 of the 70 patients, CT findings of the mediastinal lymph nodes were compared to the pathology following complete sampling. The overall accuracy of the mediastinal CT was 60.0 per cent (12 true positive and 12 true negative), but the negative predictable value was 12/(12 + 3) or 80.0 per cent, whereas 3 were false negatives though they showed an acceptable postoperative course. Sixteen out of 21 patients with one, or at the most, three enlarged nodes detected on CT also did well postoperatively and retrospectively, were considered not to have required mediastinoscopy. A group of patients showing no, or at the most, three enlarged mediastinal lymph nodes on CT may be considered as candidates for surgery even without mediastinoscopy. Multi-organ survey by means of CT was believed cost-ineffective and omittable. Bone scan however, retrospectively detected three true positives among 20 patients with a positive uptake, so that it cannot be omitted out of hand, though further examination of this point is required.

  8. Study Finds Small Increase in Cancer Risk after Childhood CT Scans

    Science.gov (United States)

    A study published in the June 6, 2012, issue of The Lancet shows that radiation exposure from computed tomography (CT) scans in childhood results in very small but increased risks of leukemia and brain tumors in the first decade after exposure.

  9. False Positive Uptake in Bilateral Gynecomastia on 68Ga-PSMA PET/CT Scan.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Nair, Bindu P; Pillai, M R A; Madhavan, Jayaprakash

    2017-09-01

    A 66-year-old man on hormonal therapy with prostate cancer was referred for Ga-PSMA PET/CT scan for biochemical recurrence. Ga-PSMA PET/CT scan detected moderate heterogeneous tracer concentration in bilateral breast parenchyma, in addition to the abnormal tracer concentration in enlarged prostate gland, right external iliac lymph node, and sclerotic lesion in L4 vertebra. On clinical examination, he was found to have bilateral gynecomastia. Abnormal concentration of Ga-PSMA in breast cancer is now well known, and in this context, it is important to know that tracer localization can occur in gynecomastia as well, as evidenced in this case.

  10. Pure ground glass nodular adenocarcinomas: Are preoperative positron emission tomography/computed tomography and brain magnetic resonance imaging useful or necessary?

    Science.gov (United States)

    Cho, Hyoun; Lee, Ho Yun; Kim, Jhingook; Kim, Hong Kwan; Choi, Joon Young; Um, Sang-Won; Lee, Kyung Soo

    2015-09-01

    The utility of (18)F-Fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning and brain magnetic resonance imaging (MRI) as a staging workup for lung adenocarcinoma manifesting as pure ground glass opacity (GGO) is unknown. The purpose of this study was to determine the utility of these 2 tests for preoperative staging of pure GGO nodular lung adenocarcinoma. The study included 164 patients (male:female, 73:91; mean age, 62 years) with pure GGO nodular lung adenocarcinoma who underwent PET/CT (in 136 patients) and/or brain MRI (in 109 patients) before surgery. Pathologic N staging and dedicated standard imaging or follow-up imaging findings for M staging were used as reference standards. The median follow-up time was 47.9 months. On PET/CT scan, abnormal FDG uptake of lymph nodes was found in 2 of 136 patients (1.5%); both were negative on final pathology. Abnormal FDG uptake of the liver was detected in 1 patient, which was also confirmed to be negative by dedicated abdominal CT. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of PET/CT in detecting metastases were not applicable, 98% (95% confidence interval [CI], 94%-100%), 0% (95% CI, 0%-71%), 100% (95% CI, 97%-100%), and 98% (95% CI, 94%-100%), respectively. No brain metastasis was found in preoperative brain MRI of 109 patients. Of 109 patients, 1 (0.9%) developed brain metastasis 30 months after surgical resection. PET/CT and brain MRI is not necessary in the staging of pure GGO nodular lung adenocarcinoma. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Combined endeavor of Neutrosophic Set and Chan-Vese model to extract accurate liver image from CT scan.

    Science.gov (United States)

    Siri, Sangeeta K; Latte, Mrityunjaya V

    2017-11-01

    Many different diseases can occur in the liver, including infections such as hepatitis, cirrhosis, cancer and over effect of medication or toxins. The foremost stage for computer-aided diagnosis of liver is the identification of liver region. Liver segmentation algorithms extract liver image from scan images which helps in virtual surgery simulation, speedup the diagnosis, accurate investigation and surgery planning. The existing liver segmentation algorithms try to extort exact liver image from abdominal Computed Tomography (CT) scan images. It is an open problem because of ambiguous boundaries, large variation in intensity distribution, variability of liver geometry from patient to patient and presence of noise. A novel approach is proposed to meet challenges in extracting the exact liver image from abdominal CT scan images. The proposed approach consists of three phases: (1) Pre-processing (2) CT scan image transformation to Neutrosophic Set (NS) and (3) Post-processing. In pre-processing, the noise is removed by median filter. The "new structure" is designed to transform a CT scan image into neutrosophic domain which is expressed using three membership subset: True subset (T), False subset (F) and Indeterminacy subset (I). This transform approximately extracts the liver image structure. In post processing phase, morphological operation is performed on indeterminacy subset (I) and apply Chan-Vese (C-V) model with detection of initial contour within liver without user intervention. This resulted in liver boundary identification with high accuracy. Experiments show that, the proposed method is effective, robust and comparable with existing algorithm for liver segmentation of CT scan images. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Evaluation of radioactive seeds implantation under PET-CT guidance for the treatment of central lung cancer with obstructive atelectasis

    International Nuclear Information System (INIS)

    Zhou Yi; Jiang Zhongpu; Wang Haiting; Zhang Yanjun; Jiang Qiang; Wang Jun; Ren Lijun; Xie Bin

    2010-01-01

    Objective: To evaluate percutaneous puncturing 125 I seed implantation by using PET-CT guided target localization technique in treating central lung cancer complicated by obstructive pulmonary atelectasis. Methods: A total of 30 patients with suspected central lung cancer complicated by obstructive pulmonary atelectasis on preoperative chest films were enrolled in this study. As no clear distinction existed between the tumor and the atelectatic consolidation shadow on plain chest films, CT scanning was carried out in all patients. If CT scan was still not able to determine the margin of the tumor, an additional PET-CT scanning was adopted. After ascertaining the location of the lung cancer, percutaneous puncturing implantation of 125 I seeds under PET-CT guidance was performed. The clinical data and the therapeutic results were evaluated. Results: A sharp distinction between the tumor and the atelectatic consolidation shadow was demonstrated on PET-CT scans in 21 cases. The mean volume of the targeted lesion reckoned from PET-CT scans was 26 cm 3 , and the 125 I seeds were implanted. The mean volume of the targeted lesion calculated on CT scans was 37 cm 3 . Six months after the treatment, the follow-up CT exam showed that the effective rate was 93% (28/30). The one-year survival rate was 100% . The complications included pneumothorax (n = 8), small amount of hemoptysis (n = 12) and fever (n = 2). No displacement or immigration of the implanted seeds occurred. Conclusion: PET-CT scanning is far superior to conventional CT scanning in determining the target area of the tumor in patients with central lung cancer complicated by obstructive pulmonary atelectasis. (authors)

  13. CT reconstruction technique in lumbar intraneuroforaminal disc herniation

    International Nuclear Information System (INIS)

    Volle, E.; Claussen, C.; Kern, A.; Stoltenburg, G.

    1988-01-01

    The CT appearance of the lumbar neural foramina and contents is described in detail and compared to histopathological specimens. Direct axial scans with secondary sagittal, coronal and paraxial reconstruction series of slices of the neuralforamen were derived from lumbar spine examination of fifty normal adults. These normal parameters were then used to evaluate and subdivide 20 patients with disc herniation involving the neuralforamen. The new paraxial reformation was able to show an intraneuroforaminal disc involvement. CT-reformation technique and operative results in intraneuroforaminal disc herniation correspond in 80%. This improvement in preoperative diagnosis demonstrates to the neurosurgeon the full extent of disc herniation and results in an optimized operative approach. (orig.)

  14. CT reconstruction technique in lumbar intraneuroforaminal disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Volle, E.; Claussen, C.; Kern, A.; Stoltenburg, G.

    1988-04-01

    The CT appearance of the lumbar neural foramina and contents is described in detail and compared to histopathological specimens. Direct axial scans with secondary sagittal, coronal and paraxial reconstruction series of slices of the neuralforamen were derived from lumbar spine examination of fifty normal adults. These normal parameters were then used to evaluate and subdivide 20 patients with disc herniation involving the neuralforamen. The new paraxial reformation was able to show an intraneuroforaminal disc involvement. CT-reformation technique and operative results in intraneuroforaminal disc herniation correspond in 80%. This improvement in preoperative diagnosis demonstrates to the neurosurgeon the full extent of disc herniation and results in an optimized operative approach.

  15. Quantifying the impact of µCT-scanning of human fossil teeth on ESR age results.

    Science.gov (United States)

    Duval, Mathieu; Martín-Francés, Laura

    2017-05-01

    Fossil human teeth are nowadays systematically CT-scanned by palaeoanthropologists prior to any further analysis. It has been recently demonstrated that this noninvasive technique has, in most cases, virtually no influence on ancient DNA preservation. However, it may have nevertheless an impact on other techniques, like Electron Spin Resonance (ESR) dating, by artificially ageing the apparent age of the sample. To evaluate this impact, we µCT-scanned several modern enamel fragments following the standard analytical procedures employed by the Dental Anthropology Group at CENIEH, Spain, and then performed ESR dose reconstruction for each of them. The results of our experiment demonstrate that the systematic high-resolution µCT-scanning of fossil hominin remains introduces a nonnegligible X-ray dose into the tooth enamel, equivalent to 15-30 Gy depending on the parameters used. This dose may be multiplied by a factor of ∼8 if no metallic filter is used. However, this dose estimate cannot be universally extrapolated to any µCT-scan experiment but has instead to be specifically assessed for each device and set of parameters employed. The impact on the ESR age results is directly dependent on the magnitude of the geological dose measured in fossil enamel but could potentially lead to an age overestimation up to 40% in case of Late Pleistocene samples, if not taken into consideration. © 2017 Wiley Periodicals, Inc.

  16. A fully automatic end-to-end method for content-based image retrieval of CT scans with similar liver lesion annotations.

    Science.gov (United States)

    Spanier, A B; Caplan, N; Sosna, J; Acar, B; Joskowicz, L

    2018-01-01

    The goal of medical content-based image retrieval (M-CBIR) is to assist radiologists in the decision-making process by retrieving medical cases similar to a given image. One of the key interests of radiologists is lesions and their annotations, since the patient treatment depends on the lesion diagnosis. Therefore, a key feature of M-CBIR systems is the retrieval of scans with the most similar lesion annotations. To be of value, M-CBIR systems should be fully automatic to handle large case databases. We present a fully automatic end-to-end method for the retrieval of CT scans with similar liver lesion annotations. The input is a database of abdominal CT scans labeled with liver lesions, a query CT scan, and optionally one radiologist-specified lesion annotation of interest. The output is an ordered list of the database CT scans with the most similar liver lesion annotations. The method starts by automatically segmenting the liver in the scan. It then extracts a histogram-based features vector from the segmented region, learns the features' relative importance, and ranks the database scans according to the relative importance measure. The main advantages of our method are that it fully automates the end-to-end querying process, that it uses simple and efficient techniques that are scalable to large datasets, and that it produces quality retrieval results using an unannotated CT scan. Our experimental results on 9 CT queries on a dataset of 41 volumetric CT scans from the 2014 Image CLEF Liver Annotation Task yield an average retrieval accuracy (Normalized Discounted Cumulative Gain index) of 0.77 and 0.84 without/with annotation, respectively. Fully automatic end-to-end retrieval of similar cases based on image information alone, rather that on disease diagnosis, may help radiologists to better diagnose liver lesions.

  17. Evaluation of optimal scan duration and end time in cerebral CT perfusion study

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Sugawara, Yoshifumi; Miki, Hitoshi; Mochizuki, Teruhito; Murase, Kenya

    2005-01-01

    The purpose of this study was to evaluate the optimal end time of scanning and the influence of varying the number of source images adopted for calculation of the parameter values in computerized tomography (CT) perfusion. Nineteen CT perfusion studies in 14 patients with cerebrovascular disease were retrospectively analyzed. CT perfusion scanning was performed using continuous scans of 1 sec/rotation x 60 sec with 5-mm-thick sections. To determine the appropriate end time of scanning, the time-density curves (TDCs) of the anterior cerebral artery (ACA), superior sagittal sinus (SSS), and basal ganglia were analyzed. The functional maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) were retrospectively generated from various numbers (30, 35, 40, 45, 50, 55, and 60) of source images. Defining the values calculated from the number of source images equal to the end time of the first pass as standard values, the percentage difference between the standard values and the values generated from various numbers of sources were evaluated. The TDCs of SSS showed the latest end time of the first pass (mean, 38.6±5.2 sec; range, 32 to 48 sec). Therefore, the values calculated from the number of source images equal to the end time of the first pass of SSS were defined as standard values. Increase and decrease of the number of source images for calculation resulted in increase of the percentage difference in every parameter value. The percentage differences ranged up to 49.6% for CBF, 48.0% for CBV, and 20.0% for MTT. Scanning until the end time of the first pass of SSS is necessary and sufficient for reliable measurement. Variable scan time based on the TDC of the SSS may be of better utility than use of fixed scan time. Further, the radiation dose could be minimized in many cases by reducing the scan time. (author)

  18. Optimization of individualized abdominal scan protocol with 64-slice CT scanner

    International Nuclear Information System (INIS)

    Hu Minxia; Zhao Xinming; Song Junfeng; Zhou Chunwu

    2012-01-01

    Objective: To explore an individualized abdominal scan protocol with a 64-slice CT scanner. Methods: From Sep. 2010 to Nov. 2010, one hundred consecutive patients, who underwent twice non-contrast-enhanced abdominal CT scans within 3 months, were enrolled in this study. For each patient, the tube current of 274 eff. mAs and 207 eff. mAs were applied respectively in the first and second abdominal scan. The imaging qualities of the two scans were evaluated retrospectively by 3 reviewers. All the individual variants,including height, weight, body mass index (BMI), the maximum transverse diameter, the anteroposterior diameter and the average maximum diameter of abdomen were recorded. A five-point scale was used for grading the image noise of eight organs, including abdominal aorta, portal vein, liver, spleen, gallbladder, pancreas, renal cortex and renal medulla. Diagnostic acceptability of CT images at three anatomic levels,including porta hepatis, pancreas and the upper pole of renal, was also evaluated by using a five-point scale. The noise value of abdominal aorta was defined as the standard deviation (SD) of CT values of aorta at the level of porta hepatis. Scatter diagram and Pearson correlation analysis were used for evaluating the linear relationship between the individual variants and the noise value of abdominal aorta, and multivariate linear regression analysis was used for evaluating the relevance between the individual variants and the noise value of aorta. Results: In this patients group, the average height was (164.6 ± 7.5) cm,the average weight was (64.3 ± 11.0) kg, the BMI was (23.7 ±3.3) kg/m 2 , the maximum transverse diameter of abdomen was (29.8 ± 2.3) cm, the anteroposterior diameter of abdomen was (23.1 ± 2.9) cm, and the average maximum diameter of abdomen was (26.5 ± 2.5) cm. Pearson correlation analysis showed significant positive linear correlation between the noise value of abdominal aorta (1 1.7 ± 3.0) and patients' weight (r=0

  19. 18F-FDG SPECT/CT in the diagnosis of differentiated thyroid carcinoma with elevated thyroglobulin and negative iodine-131 scans

    International Nuclear Information System (INIS)

    Ma, C.; Wu, Z.; Wang, H.; Wang, X.; Shao, M.; Zhao, L.; Jiawei, X.

    2015-01-01

    Aim of the present study was to investigate the usefulness of 18 F-FDG SPECT/CT in differentiated thyroid cancer (DTC) with elevated serum thyroglobulin (Tg) but negative iodine-131 scan. This retrospective review of patients with DTC recurrence who had 18 F-FDG SPECT/CT and 18 F-FDG PET/CT for elevated serum Tg but negative iodine-131 scan (March 2007-October 2012). After total thyroidectomy followed by radioiodine ablation, 86 consecutive patients with elevated Tg levels underwent 18 F-FDG SPECT/CT or 18 F-FDG PET/CT. Of these, 45 patients had 18 F-FDG SPECT/CT, the other 41 patients had 18 F-FDG PET/CT 3-4 weeks after thyroid hormone withdrawal. The results of 18 F-FDG PET/CT and SPECT/CT were correlated with patient follow-up information, which included the results from subsequent imaging modalities such as neck ultrasound, MRI and CT, Tg levels, and histologic examination of surgical specimens. The diagnostic accuracy of the two imaging modalities was evaluated. In 18 F-FDG SPECT/CT scans, 24 (24/45) patients had positive findings, 22 true positive in 24 patients, false positive in 2 patients, true-negative and false-negative in 6, 15 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG SPECT/CT were 59.5%, 75% and 62.2%, respectively. Twenty six patients had positive findings on 18 F-FDG PET/CT scans, 23 true positive in 26 (26/41) patients, false positive in 3 patients, true-negative and false-negative in 9, 6 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 79.3%, 81.8% and 78.1%, respectively. Clinical management changed for 13 (29%) of 45 patients by 18 F-FDG SPECT/CT, 14 (34%) of 41 patients by 18F-FDG PET/CT including surgery, radiation therapy, or multi kinase inhibitor. Based on the retrospective analysis of 86 patients, 18F-FDG SPECT/CT has lower sensitivity in the diagnosis of DTC recurrence with elevated Tg and negative iodine-131scan to 18F-FDG PET/CT. The clinical

  20. Case of idiopathic portalhypertension. Comparison of pre- and post-operative CT scan findings of collateral circulation

    Energy Technology Data Exchange (ETDEWEB)

    Serizawa, K; Yajima, Y; Onodera, H; Hirata, T; Sugawara, H [Tohoku Univ., Sendai (Japan). School of Medicine

    1982-02-01

    A 40-year-old man was referred to our clinic for esophageal varices. Histological examination of the liver biopsy samples revealed no sign of liver cirrhosis. Celiac angiography and ultrasound showed no obstruction of portal vein. A diagnosis of idiopathic portalhypertension was established. Splenomegaly and collateral circulation from spleen to left retroperitoneum were shown on CT scan and confirmed by surgical operation. CT scan following operation showed no collateral circulation.

  1. CT scan and histological findings in experimental cerebral infarctions in cats

    International Nuclear Information System (INIS)

    Morimoto, Tetsuya

    1981-01-01

    Experimental cerebral infarctions were made in sixty-five cats by the transorbital approach. CT scanning was done at various periods after right-middle cerebral artery occlusion, and all cases were studied histopathologically. Cerebral microcirculation was studied by the carbon perfusion method, and blood-brain barrier (BBB) dysfunction was studied by intravenous fluorescein administration. The iodine content of brain tissue was measured and this value was compared with the findings on CT scan. Experimental cerebral infarction was divided into four stages according to CT scan findings. These are the pre-edema stage, edema stage, edema diminishing stage, and cavity stage. The low density area (LDA) in the edema stage has a mass effect and a spongy appearance is seen histopathologically. LDA in the edema diminishing stage is localized to the extent of the macroscopic infarcted region, and macrophage (so called ''gitter cells'') and capillaries are seen. Fluorescein stain indicating the area of BBB dysfunction shows almost the same extent as the area of disturbed microcirculation indicated by impaired carbon filling. In the edema diminishing stage, there is good carbon filling in the infarcted region, and enlarged capillaries with carbon black inside are seen. The study of iodine content showed that the iodine level is very high in the infarcted region, and the level has good correlation with the number of capillaries. The mechanism of contrast enhancement in the cerebral infarction seems to be well linked to the capillaries with BBB dysfunction. This study indicates that the contrast medium leaks through the capillary wall. (author)

  2. Computer-assisted solid lung nodule 3D volumetry on CT : influence of scan mode and iterative reconstruction: a CT phantom study

    NARCIS (Netherlands)

    Coenen, Adriaan; Honda, Osamu; van der Jagt, Eric J.; Tomiyama, Noriyuki

    2013-01-01

    To evaluate the effect of high-resolution scan mode and iterative reconstruction on lung nodule 3D volumetry. Solid nodules with various sizes (5, 8, 10 and 12 mm) were placed inside a chest phantom. CT images were obtained with various tube currents, scan modes (conventional mode, high-resolution

  3. The value of brain scanning in cerebro-vascular disease by CT

    International Nuclear Information System (INIS)

    Huber, G.; Emde, H.

    1980-01-01

    Brain scanning by scintigraphy and CT studies of the brain are complementary methods. The precise demonstration of the anatomy and the pathology of the brain by CT is supplemented by brain scintigraphy due to the latter's value to assess the hemodynamic properties of a lesion and thus provide important clues to its site and sometimes even its histology. This is especially true in vascular brain disease thus either dispensing the need for an invasive procedure such as angiography or providing information for a specific approach. (orig.) 891 MG/orig. 892 MKO [de

  4. A vast increase in the use of CT scans for investigating occult hip fractures

    International Nuclear Information System (INIS)

    Jordan, Robert; Dickenson, Edward; Westacott, Daniel; Baraza, Njalalle; Srinivasan, Kuntrapka

    2013-01-01

    Background: Early diagnosis in neck of femur fractures has been shown to improve outcome. The National Institute for Clinical Excellence recommends if an occult hip fracture is suspected then an MRI should be performed and if not available within 24 h a CT should be considered. At our centre, emergency MRI is rarely available and so CT is commonly used. Objectives: Our study aims to analyse the trends in CT use over a five year period for the diagnosis of neck of femur fractures. Methods: Both the number of patients with a hip fracture and those undergoing a CT hip to diagnose an occult injury were identified across two district general hospitals between 2006–2007 and 2010–2011. The time from initial radiograph to CT and initial radiograph to operation were calculated. Results: In 2006–2007, of 547 hip fractures, 20 CT hips were performed and 6 reported as a fractured neck of femur (30%). In 2010–2011, of 499 hip fractures, 239 CT hips were performed and 65 fractures were recognised (27%). The mean time from radiograph until CT scan was 2.0 days in 2007 and 3.2 days in 2011, which was a statistically significant difference (p < 0.001). For those diagnosed using a CT scan the mean time from admission X-ray to surgery was 1.2 days in 2007 and 3.6 days in 2011. Conclusion: Clinicians are becoming increasingly reliant on CT for the diagnosis of hip fractures with our data suggesting further imaging is one factor that can delay time to diagnosis and theatre

  5. A vast increase in the use of CT scans for investigating occult hip fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Robert, E-mail: Robert.jordan@doctors.org.uk; Dickenson, Edward, E-mail: edwarddickenson@doctors.org.uk; Westacott, Daniel, E-mail: dan_westacott@hotmail.com; Baraza, Njalalle, E-mail: njaleb@Doctors.Org.Uk; Srinivasan, Kuntrapka, E-mail: bijusri@Yahoo.Co.Uk

    2013-08-15

    Background: Early diagnosis in neck of femur fractures has been shown to improve outcome. The National Institute for Clinical Excellence recommends if an occult hip fracture is suspected then an MRI should be performed and if not available within 24 h a CT should be considered. At our centre, emergency MRI is rarely available and so CT is commonly used. Objectives: Our study aims to analyse the trends in CT use over a five year period for the diagnosis of neck of femur fractures. Methods: Both the number of patients with a hip fracture and those undergoing a CT hip to diagnose an occult injury were identified across two district general hospitals between 2006–2007 and 2010–2011. The time from initial radiograph to CT and initial radiograph to operation were calculated. Results: In 2006–2007, of 547 hip fractures, 20 CT hips were performed and 6 reported as a fractured neck of femur (30%). In 2010–2011, of 499 hip fractures, 239 CT hips were performed and 65 fractures were recognised (27%). The mean time from radiograph until CT scan was 2.0 days in 2007 and 3.2 days in 2011, which was a statistically significant difference (p < 0.001). For those diagnosed using a CT scan the mean time from admission X-ray to surgery was 1.2 days in 2007 and 3.6 days in 2011. Conclusion: Clinicians are becoming increasingly reliant on CT for the diagnosis of hip fractures with our data suggesting further imaging is one factor that can delay time to diagnosis and theatre.

  6. A proposal for combined MRI and PET/CT interpretation criteria for preoperative nodal staging in non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Kim, Yoo Na; Yi, Chin A.; Lee, Kyung Soo; Lee, Ho Yun; Kim, Tae Sung; Chung, Myung Jin; Kwon, O.Jung; Chung, Man Pyo; Kim, Byung-Tae; Choi, Joon Young; Kim, Seon Woo; Han, Joungho; Shim, Young Mog

    2012-01-01

    To determine the positive reading criteria for malignant nodes when interpreting combined MRI and PET/CT images for preoperative nodal staging in non-small-cell lung cancer (NSCLC). Forty-nine patients with biopsy-proven NSCLC underwent both PET/CT and thoracic MRI [diffusion weighted imaging (DWI)]. Each nodal station was evaluated for the presence of metastasis by applying either inclusive (positive if either one read positive) or exclusive (positive if both read positive) criteria in the combined interpretation of PET/CT and MRI. Nodal stage was confirmed pathologically. The combined diagnostic accuracy of PET/CT and MRI was determined on per-nodal station and per-patient bases and compared with that of PET/CT alone. In 49 patients, 39 (19%) of 206 nodal stations harboured malignant cells. Out of 206 nodal stations, 186 (90%) had concordant readings, while the rest (10%) had discordant readings. Inclusive criteria of combined PET/CT and MRI helped increase sensitivity for detecting nodal metastasis (69%) compared with PET/CT alone (46%; P = 0.003), while specificity was not significantly decreased. Inclusive criteria in combined MRI and PET/CT readings help improve significantly the sensitivity for detecting nodal metastasis compared with PET/CT alone and may decrease unnecessary open thoracotomy. (orig.)

  7. A case of linear nevus sebaceous syndrome showing abnormalities by head CT scan

    International Nuclear Information System (INIS)

    Matsuda, Yoshio; Kuraya, Kazue; Sumiyoshi, Minoru; Seki, Shuichiro; Murakami, Naoki

    1982-01-01

    A female baby weighing 2,702 g, who was delivered spontaneously after 37 weeks of gestation, showed linear nevus sebaceous syndrome with abnormalities on EEG and head CT scan. Immediately after birth, the baby showed abnormalities of the skin in the left half of the body, especially from the head to the face. At the same time, EEG showed a low voltage on the affected side, and head CT scan showed expansion of the lateral ventricle. Funduscopic findings showed retinochoroidal toxoplasmosis-like degeneration. This disease has been rarely reported. An early diagnosis is seemed to be important since the skin lesion per se was premalignant, and generalized abnormalities including those of the central nervous system occurred concurrently. (Chiba, N.)

  8. CT colonography for preoperative examination of the proximal colon using a transanal drainage tube for acute malignant colonic obstruction

    International Nuclear Information System (INIS)

    Sasaki, Kazuaki; Hirano, Yuji; Oono, Keisuke; Sasaki, Kazunori; Someya, Tetsufumi; Harada, Keisuke; Ezoe, Eiri; Furuhata, Tomohisa; Hirata, Koichi

    2011-01-01

    The purpose of this study was to evaluate the feasibility of CT colonography for preoperative examination of the proximal colon using a transanal drainage tube in patients with acute colon obstruction caused by colorectal cancer. Ten patients who received initial treatment for acute malignant colon obstruction at our hospital between June 2004 and December 2008 were studied. In these patients, elective surgery was possible after transanal drainage tube insertion, and the colon on the oral side from the cancer lesion was examined using a drainage tube. Air was injected through the tube into the oral side of the colon, and CT colonography was assessed for the presence or absence of lesions on the oral side. The images of the oral side of the colon were good enough to allow adequate interpretation in 9 of the 10 patients. In the first patient, the visualization of the area near the lesion was somewhat fair, although the right side colon was well visualized. There were no complications associated with this examination. The present preoperative examination using a transanal drainage tube was useful for determining the extent of intestinal resection when patients were not candidates for colonoscopy or barium enema examination. (author)

  9. Fuzzy-neural network in the automatic detection and volumetry of the spleen on spiral CT scans

    International Nuclear Information System (INIS)

    Heitmann, K.R.; Mainz Univ.; Rueckert, S.; Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Uthmann, T.

    2000-01-01

    Purpose: To assess spleen segmentation and volumetry in spiral CT scans with and without pathological changes of splenic tissue. Methods: The image analysis software HYBRIKON is based on region growing, self-organized neural nets, and fuzzy-anatomic rules. The neural nets were trained with spiral CT data from 10 patients, not used in the following evaluation on spiral CT scans from 19 patients. An experienced radiologist verified the results. The true positive and false positive areas were compared in terms to the areas marked by the radiologist. The results were compared with a standard thresholding method. Results: The neural nets achieved a higher accuracy than the thresholding method. Correlation coefficient of the fuzzy-neural nets: 0.99 (thresholding: 0.63). Mean true positive rate: 90% (thresholding: 75%), mean false positive rate: 5% (thresholding>100%). Pitfalls were caused by accessory spleens, extreme changes in the morphology (tumors, metastases, cysts), and parasplenic masses. Conclusions: Self-organizing neural nets combined with fuzzy rules are ready for use in the automatic detection and volumetry of the spleen in spiral CT scans. (orig.) [de

  10. Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory

    International Nuclear Information System (INIS)

    Hu, Zhanli; Zou, Jing; Gui, Jianbao; Zheng, Hairong; Xia, Dan

    2013-01-01

    Dental CT is the most appropriate and accurate device for preoperative evaluation of dental implantation. It can demonstrate the quantity of bone in three dimensions (3D), the location of important adjacent anatomic structures and the quality of available bone with minimal geometric distortion. Nevertheless, with the rapid increase of dental CT examinations, we are facing the problem of dose reduction without loss of image quality. In this work, backprojection-filtration (BPF) and Feldkamp–Davis–Kress (FDK) algorithm was applied to reconstruct the 3D full image and region-of-interest (ROI) image from complete and truncated circular cone-beam data respectively by computer-simulation. In addition, the BPF algorithm was evaluated based on the 3D ROI-image reconstruction from real data, which was acquired from our developed circular cone-beam prototype dental CT system. The results demonstrated that the ROI-image quality reconstructed from truncated data using the BPF algorithm was comparable to that reconstructed from complete data. The FDK algorithm, however, created artifacts while reconstructing ROI-image. Thus it can be seen, for circular cone-beam dental CT, reducing scanning angular range of the BPF algorithm used for ROI-image reconstruction are helpful for reducing the radiation dose and scanning time. Finally, an analytical method was developed for estimation of the ROI projection area on the detector before CT scanning, which would help doctors to roughly estimate the total radiation dose before the CT examination. -- Highlights: ► BPF algorithm was applied by using dental CT for the first time. ► A method was developed for estimation of projection region before CT scanning. ► Roughly predict the total radiation dose before CT scans. ► Potential reduce imaging radiation dose, scatter, and scanning time

  11. Advantages of hybrid SPECT-CT imaging in preoperative localization of parathyroid glands in a patient with secondary hyperparathyroidism. A case report

    International Nuclear Information System (INIS)

    Cytawa, Wojciech; Teodorczyk, Jacek; Lass, Piotr

    2013-01-01

    Secondary hyperparathyroidism is a frequent complication of chronic renal failure. Patients resistant to pharmacotherapy are candidates for parathyroidectomy. Invasiveness of surgical treatment can be minimized by precise preoperative localization of parathyroid glands. Imaging modalities routinely used for this purpose are ultrasonography and MIBI-Tc99m scintigraphy. Our case report shows advantages of co-registered computer tomography and conventional SPECT imaging (SPECT/CT) in a patient with advanced secondary hyperparathyroidism successfully treated with surgery. Hybrid SPECT/CT parathyroid imaging enables better surgical planning and is superior to conventional scintigraphy

  12. Differential Aging Signals in Abdominal CT Scans.

    Science.gov (United States)

    Orlov, Nikita V; Makrogiannis, Sokratis; Ferrucci, Luigi; Goldberg, Ilya G

    2017-12-01

    Changes in the composition of body tissues are major aging phenotypes, but they have been difficult to study in depth. Here we describe age-related change in abdominal tissues observable in computed tomography (CT) scans. We used pattern recognition and machine learning to detect and quantify these changes in a model-agnostic fashion. CT scans of abdominal L4 sections were obtained from Baltimore Longitudinal Study of Aging (BLSA) participants. Age-related change in the constituent tissues were determined by training machine classifiers to differentiate age groups within male and female strata ("Younger" at 50-70 years old vs "Older" at 80-99 years old). The accuracy achieved by the classifiers in differentiating the age cohorts was used as a surrogate measure of the aging signal in the different tissues. The highest accuracy for discriminating age differences was 0.76 and 0.72 for males and females, respectively. The classification accuracy was 0.79 and 0.71 for adipose tissue, 0.70 and 0.68 for soft tissue, and 0.65 and 0.64 for bone. Using image data from a large sample of well-characterized pool of participants dispersed over a wide age range, we explored age-related differences in gross morphology and texture of abdominal tissues. This technology is advantageous for tracking effects of biological aging and predicting adverse outcomes when compared to the traditional use of specific molecular biomarkers. Application of pattern recognition and machine learning as a tool for analyzing medical images may provide much needed insight into tissue changes occurring with aging and, further, connect these changes with their metabolic and functional consequences. Published by Elsevier Inc.

  13. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  14. Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer

    Directory of Open Access Journals (Sweden)

    Saima Riaz

    2017-06-01

    Full Text Available Objective(s: Small cell lung cancer (SCLC is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM staging of SCLC, compared to the conventional computed tomography (CT scan and its potential role as a prognosticator.Methods: This retrospective review was conducted on 23 patients, who were histopathologically diagnosed to have SCLC and referred for undergoing 18F-FDG PET/CT scanning during October 2009-December 2015. The rate of agreement between the CT and 18F-FDG PET/CT findings for TNM staging was calculated using the Cohen’s kappa (κ. The median follow-up time was eight months, ranging 27-3 months. The overall and disease-free survival rates were calculated based on the extent of disease.Results: 19 cases were male and four female with the mean age of 58±9 years. The 18F-FDG PET/CT identified limited and extensive diseases in 2 (8.7% and 21 (91.3% patients, respectively. In addition, the results of the Cohen’s kappa demonstrated a strong (κ=0.82, fair (κ=0.24, and poor (κ=0.12 agreement between the PET/CT and CT findings for determining tumor, node, and metastasis stages, respectively. The 18F-FDG PET/CT scans upstaged disease in 47% of the cases with visceral and osseous metastasis. The disease-free survival rates for the limited and extensive diseases were 100% and 23% within the 12-month follow-up. In addition, 8 (35% patients expired during the follow-up period.Conclusion: Improved nodal and metastatic disease identification highlights the role of 18F-FDG PET/CT scanning in initial staging of SCLC with prognostic implications.

  15. 3D quantification of soil structure and functioning based on PET and CT scanning techniques

    DEFF Research Database (Denmark)

    Garbout, Amin

    This thesis explores the potential of PET and CT scanning techniques to quantify and visualize soil structure, root development, and soil/plant interactions. At the investigated scale, these non-invasive and nondestructive techniques have some obvious advantages compared with most other techniques....... The processed measurements show some expected and a few unexpected effects (or lack of effects) on different characteristics of soil structure. The combination of CT and PET scanning in an air plant soil controller system revealed some very interesting research possibilities. Interactions between soil structure...

  16. [Indications and instructions to patients for a positron emission tomography-PET scan. The importance of the hybridic PET/CT-computerised tomography scan and which specialty should be responsible for its function].

    Science.gov (United States)

    Grammaticos, Philip; Datseris, Ioannis; Gerali, Sofia; Papantoniou, Vassilios; Valsamaki, Pipitsa; Boundas, Dimitrios

    2007-01-01

    Indications and instructions to patients for performing a positron emission tomography - PET scan are mentioned. Although PET camera was developed in 1970 its clinical indications were established in about 1998. The hybridic PET/CT- computerized tomography scanner appeared in 2001 and its clinical indications are still under discussion. These discussions refer to both the use of PET/CT as an acquisition correction and anatomic localization device for PET images (AC/A) and to its use as a diagnostic CT scan (dCT). Most of the patients submitted for a PET scan have already done a dCT scan. This was the case in 286 out of the first 300 patients referred to "Evangelismos" hospital in Athens for a PET scan. These two scans can be matched electronically. Extra cost, space, personnel and radiation absorption dose especially in children, are additional factors to be considered in using the PET/CT scanner. The specialty of Nuclear Medicine is now based on the PET camera, its best part and main equipment for molecular imaging. It is very much easier and faster for a Nuclear Medicine physician who routinely reports tomographic PET and SPET images, to be familiar with the CT images than for a Radiologist to get to "know how" about the PET camera and the whole Nuclear Medicine Department. Nuclear Medicine is about open radiation sources, molecular imaging, specific radio-pharmacology, radiobiology, radiation protection etc, while on the other hand in some countries, Nuclear Physicians have already spent, as part of their official training, six months in a Radiology Department whose function is considered to be at least 25% about the CT scanner. We come to the conclusion that the PET/CT scanner should be under the responsibility of the Nuclear Medicine Department and the Radiologist should act as an advisor.

  17. Dose responses in a normoxic polymethacrylic acid gel dosimeter using optimal CT scanning parameters

    Energy Technology Data Exchange (ETDEWEB)

    Cho, K.H. [Department of Radiation Oncology, College of Medicine, Soonchunhyang University, Bucheon 420-767 (Korea, Republic of); Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of); Cho, S.J. [Department of Radiation Oncology, College of Medicine, Eulji University, Seongnam 461-713 (Korea, Republic of); Lee, S. [Department of Radiation Oncology, College of Medicine, Korea University, Seoul 130-701 (Korea, Republic of); Lee, S.H. [Cheil General Hospital and Women' s Healthcare Center, Kwandong University College of Medicine, Seoul 100-380 (Korea, Republic of); Min, C.K.; Kim, Y.H.; Moon, S.K.; Kim, E.S.; Chang, A.R. [Department of Radiation Oncology, College of Medicine, Soonchunhyang University, Bucheon 420-767 (Korea, Republic of); Kwon, S.I., E-mail: sikwon@kyonggi.ac.kr [Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of)

    2012-05-21

    The dosimetric characteristics of normoxic polymethacrylic acid gels are investigated using optimal CT scanning parameters and the possibility of their clinical application is also considered. The effects of CT scanning parameters (tube voltage, tube current, scan time, slick thickness, field of view, and reconstruction algorithm) are experimentally investigated to determine the optimal parameters for minimizing the amount of noise in images obtained using normoxic polymethacrylic acid gel. In addition, the dose sensitivity, dose response, accuracy, and reproducibility of the normoxic polymethacrylic acid gel are evaluated. CT images are obtained using a head phantom that is fabricated for clinical applications. In addition, IMRT treatment planning is performed using a Tomotherapy radiation treatment planning system. A program for analyzing the results is produced using Visual C. A comparison between the treatment planning and the CT images of irradiated gels is performed. The dose sensitivity is found to be 2.41{+-}0.04 HGy{sup -1}. The accuracies of dose evaluation at doses of 2 Gy and 4 Gy are 3.0% and 2.6%, respectively, and their reproducibilities are 2.0% and 2.1%, respectively. In the comparison of gel and Tomotherpay planning, the pass rate of the {gamma}-index, based on the reference values of a dose error of 3% and a DTA of 3 mm, is 93.7%.

  18. Dose responses in a normoxic polymethacrylic acid gel dosimeter using optimal CT scanning parameters

    Science.gov (United States)

    Cho, K. H.; Cho, S. J.; Lee, S.; Lee, S. H.; Min, C. K.; Kim, Y. H.; Moon, S. K.; Kim, E. S.; Chang, A. R.; Kwon, S. I.

    2012-05-01

    The dosimetric characteristics of normoxic polymethacrylic acid gels are investigated using optimal CT scanning parameters and the possibility of their clinical application is also considered. The effects of CT scanning parameters (tube voltage, tube current, scan time, slick thickness, field of view, and reconstruction algorithm) are experimentally investigated to determine the optimal parameters for minimizing the amount of noise in images obtained using normoxic polymethacrylic acid gel. In addition, the dose sensitivity, dose response, accuracy, and reproducibility of the normoxic polymethacrylic acid gel are evaluated. CT images are obtained using a head phantom that is fabricated for clinical applications. In addition, IMRT treatment planning is performed using a Tomotherapy radiation treatment planning system. A program for analyzing the results is produced using Visual C. A comparison between the treatment planning and the CT images of irradiated gels is performed. The dose sensitivity is found to be 2.41±0.04 HGy-1. The accuracies of dose evaluation at doses of 2 Gy and 4 Gy are 3.0% and 2.6%, respectively, and their reproducibilities are 2.0% and 2.1%, respectively. In the comparison of gel and Tomotherpay planning, the pass rate of the γ-index, based on the reference values of a dose error of 3% and a DTA of 3 mm, is 93.7%.

  19. Development of 1-year-old computational phantom and calculation of organ doses during CT scans using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Pan, Yuxi; Qiu, Rui; Ge, Chaoyong; Xie, Wenzhang; Li, Junli; Gao, Linfeng; Zheng, Junzheng

    2014-01-01

    With the rapidly growing number of CT examinations, the consequential radiation risk has aroused more and more attention. The average dose in each organ during CT scans can only be obtained by using Monte Carlo simulation with computational phantoms. Since children tend to have higher radiation sensitivity than adults, the radiation dose of pediatric CT examinations requires special attention and needs to be assessed accurately. So far, studies on organ doses from CT exposures for pediatric patients are still limited. In this work, a 1-year-old computational phantom was constructed. The body contour was obtained from the CT images of a 1-year-old physical phantom and the internal organs were deformed from an existing Chinese reference adult phantom. To ensure the organ locations in the 1-year-old computational phantom were consistent with those of the physical phantom, the organ locations in 1-year-old computational phantom were manually adjusted one by one, and the organ masses were adjusted to the corresponding Chinese reference values. Moreover, a CT scanner model was developed using the Monte Carlo technique and the 1-year-old computational phantom was applied to estimate organ doses derived from simulated CT exposures. As a result, a database including doses to 36 organs and tissues from 47 single axial scans was built. It has been verified by calculation that doses of axial scans are close to those of helical scans; therefore, this database could be applied to helical scans as well. Organ doses were calculated using the database and compared with those obtained from the measurements made in the physical phantom for helical scans. The differences between simulation and measurement were less than 25% for all organs. The result shows that the 1-year-old phantom developed in this work can be used to calculate organ doses in CT exposures, and the dose database provides a method for the estimation of 1-year-old patient doses in a variety of CT examinations. (paper)

  20. Treatment of craniopharyngioma estimated by follow-up CT

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T.; Ito, H.; Aizumi, S.; Yamamoto, S.; (Kanazawa Univ. (Japan). School of Medicine)

    1981-12-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases.

  1. Treatment of craniopharyngioma estimated by follow-up CT

    International Nuclear Information System (INIS)

    Kubota, Toshihiko; Ito, Haruhide; Aizumi, Shinichi; Yamamoto, Shinjiro

    1981-01-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases. (author)

  2. Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics

    International Nuclear Information System (INIS)

    Holiday, R.A.; Cohen, W.A.; Schinella, R.A.; Rothstein, S.G.; Persky, M.S.; Jacobs, J.M.

    1987-01-01

    Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion

  3. A case of hemiballism presenting atypical, responsive lesion by CT scan

    International Nuclear Information System (INIS)

    Kawahata, Nobuya; Honda, Masao.

    1983-01-01

    Hemiballism of the right limbs developed after cerebral infarction in an 83-year-old female patient. On admission, examination revealed hemiballism of the right limbs, monologia, disorientation of thought and motor skills, irritability and the absence of DTR in the right upper limb. Without aggressive treatment, however, involuntary movement disappeared after 18 days, and she was discharged on her own power. CT scan demonstrated a low density area in the left fronto-parietal lobe. However, no obvious abnormality in bilateral subthalamic nuclei was observed. Although the contralateral subthalamic body of Luys is involved in most instances, lesions have been reported to exist in the cerebral cortex, thalamus, corpus striatum, internal capsule and brain stem in some cases. The prognosis for this disease has been generally considered to be fatal. However, this case demonstrated an atypical lesion in CT scan, and spontaneous recovery from hemiballism took place within three weeks. Previous reports on hemiballism were reviewed, and responsive lesions and the prognosis for this case were discussed. (author)

  4. Gliomatosis cerebri followed-up with sequential CT scans report of case and a brief review

    International Nuclear Information System (INIS)

    Shiino, Akihiko; Suda, Kinya; Matsuda, Masayuki; Handa, Jyoji; Hazama, Fumitada

    1984-01-01

    Gliomatosis cerebri is a rare condition in which the tumor cells grow infiltratively and diffusely into the central nervous system without destructing the normal architechtures of the brain to a significant degree. As no single diagnostic test is highly specific to this condition, its clinical diagnosis is often very difficult. In the present case of a 71-year-old man, we could follow the course of the disease by repeated CT scans performed in 2 and a half years, and found such sequential CT scans very useful for the diagnosis of this condition. To our knowledge, this is the first report of sequential CT studies in gliomatosis cerebri. This case is reported and the relevant literature on gliomatosis cerebri is briefly reviewed. (author)

  5. Efficacy of spiral CT in the evaluation of peritoneal seeding of gastric cancer

    International Nuclear Information System (INIS)

    Choi, Hyuck Jae; Han, Joon Koo; Kim, Tae Kyoung; Kim, Ah Young; Lee, Joon Woo; Moon, Min Hoan; Yang, Han Kwang; Choi, Byung Ihn

    2001-01-01

    To determine usefulness of spiral CT in the preoperative evaluation of peritoneal seeding from a gastric carcinoma. From a database of 411 consecutive patients with surgically proven advanced gastric cancinoma obtained over a six-month period, 17 with peritoneal seeding and a control group of 24 without peritoneal seeding underwent spiral CT scanning with 7-8 mm scan thickness and interval during the portal phase. Preoperative CT images were analyzed by two readers who reached a consensus with regard to the presence and location of the ascites, thickening of the parietal peritoneum, and changes in the omentum and mesentery. Ascites was present in 47% (8/17) of patients with peritoneal seeding the right subhepatic space (n=6, 35%) and right paracolic gutter (n=5, 29%)-but not the cul-de-sac (n=2, 12%)-were common sites of fluid collection. Permeative changes in the omentum and mesentery were seen in 18% (3/17) and 12% (2/17) of patients, respectively. Among five controls with false positive results, ascites in the cul-de-sac was present in three (two males and one female, 12%) while omental nodules and a thickened peritoneum were found in two (8%) and one (4%), respectively. In nine controls with false negative results, small disseminated nodules were seen in the mesentery and omentum at surgical field. The sensitivity and specificity of spiral CT were 47% (8/17) and 79% (19/24), respectively. In terms of sensitivity and specificity, spiral CT is not especially accurate in distinguishing peritoneal seeding from gastric carcinoma

  6. A case of diffuse hemispheric gyral high density on CT scan following acute subdural hematoma in children

    International Nuclear Information System (INIS)

    Kannuki, Seiji; Oi, Shizuo

    1986-01-01

    A case of diffuse hemispheric gyral high density area following acute subdural hematoma was reported. A 2 - 10/12 year-old male was admitted to our hospital in comatous state after head injury by fall. Neurological examination revealed deep coma with anisocoria (R < L), absence of light reflex and positive bilateral Babinski reflex. CT scan disclosed left acute subdural hematoma with remarkable midline shift and tentorial herniation sign. Emergency decompressive craniectomy was performed. Posttraumatic hydrocephalus appeared after 10 days. So, ventriculoperitoneal shunt was done. The patient became gradually improved, but was in appalic state. 23 days after craniectomy, suddenly diffuse hemispheric gyral high density appeared on plain CT scan. In spite of this change, no clinical change was found. This high density spontaneously disappeared 10 days after appearance. Cerebral infarction-like phenomenon on postoperative CT scan of acute subdural hematoma in infants was sometimes reported. This phenomenon was sometimes accompanied with hemorrhagic infarction-like high density on CT scan. Diffuse hemispheric gyral high density was probably a kind of those hemorrhagic infarction-like phenomenon. Possible mechanism of this peculiar high density is discussed on the basis of characteristics of child's cerebral artery and pathophysiology of cerebral infarction. (author)

  7. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  8. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Yang, Jie [Pinnacle Health - Fox Chase Regional Cancer Center, Harrisburg, Pennsylvania 17109 (United States)

    2014-09-15

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

  9. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob; Yang, Jie

    2014-01-01

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm 3 Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT

  10. Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Yang, Dong Hyun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2010-10-15

    The potential impact of dual-source ECG-triggered sequential CT scan on coronary artery visibility has not been evaluated in free-breathing young children. To compare coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT between dual-source ECG-triggered sequential (DSET) scan and single-source non-ECG-synchronized spiral (SSNE) scan. In 93 young children, 108 cardiac 64-slice CT examinations were performed during free-breathing. Visibility of coronary arteries and side branches was compared between SSNE and DSET scans. Heart rates and trigger delays for DSET scan were recorded. Effective dose of each scan technique was calculated. Visual grades were significantly higher (P < 0.001 or =0.011) on DSET scan than on SSNE scan except for the distal left anterior descending artery. Coronary arteries were traceable in 79.3% on DSET scan and 54.3% on SSNE scan in the overlapped scan range (P < 0.0001), and 97.1% and 71.9% for the origins and proximal segments (P < 0.0001). Visibility of side branches was improved on DSET scan by a factor of 2.0. Heart rates and trigger delays for DSET scan were 131 {+-} 24 beats per min and 199 {+-} 44 ms, respectively. Effective doses of DSET and SSNE scans were 0.36 {+-} 0.12 mSv and 0.99 {+-} 0.23 mSv, respectively. DSET scan improves visibility of coronary arteries on cardiac 64-slice CT in free-breathing young children with congenital heart disease, compared with SSNE scan. (orig.)

  11. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  12. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  13. Comparison of 18F-FDG PET to CT scan in the detection of recurrent colorectal carcinoma - an ROC analysis

    International Nuclear Information System (INIS)

    Scott, A.M.; Akhurst, T.; Berlangieri, S.U.; Fitt, G.; Schelleman, T.; Jones, R.; Hannah, A.; Tochon-Danguy, H.

    2000-01-01

    Full text: This study examined 43 scans performed in 40 patients from a group of 93 prospectively enrolled in a trial examining the utility of 18 F-FDG PET in patients with potentially resectable recurrent colorectal cancer. All patients had PET and CT scans prior to surgery, where a total of 84 anatomical regions were biopsied, and 364 regions examined by the surgeons. All PET and CT scans were viewed blinded to clinical and imaging data. The scans were interpreted according to a five-point confidence scale to enable an ROC analysis to be performed. An assessment of the impact of PET over CT in patients was also made. Of the 43 cases PET and CT were concordant in 24 (56%). There were 16 cases where PET added additional diagnostic information to the benefit of the patient (37%), and three (7%) where PET alone would have lead to a potentially negative outcome. The majority of cases where PET performed better were in cases with extrahepatic disease. CT was more sensitive in the detection of pulmonary nodules, although the specificity of CT was less than PET. In conclusion, 18 F-FDG PET performed significantly better than CT both in terms of a regional analysis as well as a patient by patient basis. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  14. Relative location prediction in CT scan images using convolutional neural networks.

    Science.gov (United States)

    Guo, Jiajia; Du, Hongwei; Zhu, Jianyue; Yan, Ting; Qiu, Bensheng

    2018-07-01

    Relative location prediction in computed tomography (CT) scan images is a challenging problem. Many traditional machine learning methods have been applied in attempts to alleviate this problem. However, the accuracy and speed of these methods cannot meet the requirement of medical scenario. In this paper, we propose a regression model based on one-dimensional convolutional neural networks (CNN) to determine the relative location of a CT scan image both quickly and precisely. In contrast to other common CNN models that use a two-dimensional image as an input, the input of this CNN model is a feature vector extracted by a shape context algorithm with spatial correlation. Normalization via z-score is first applied as a pre-processing step. Then, in order to prevent overfitting and improve model's performance, 20% of the elements of the feature vectors are randomly set to zero. This CNN model consists primarily of three one-dimensional convolutional layers, three dropout layers and two fully-connected layers with appropriate loss functions. A public dataset is employed to validate the performance of the proposed model using a 5-fold cross validation. Experimental results demonstrate an excellent performance of the proposed model when compared with contemporary techniques, achieving a median absolute error of 1.04 cm and mean absolute error of 1.69 cm. The time taken for each relative location prediction is approximately 2 ms. Results indicate that the proposed CNN method can contribute to a quick and accurate relative location prediction in CT scan images, which can improve efficiency of the medical picture archiving and communication system in the future. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) Combined with Positron Emission Tomography-Computed Tomography (PET-CT) and Video-Electroencephalography (VEEG) Have Excellent Diagnostic Value in Preoperative Localization of Epileptic Foci in Children with Epilepsy.

    Science.gov (United States)

    Wang, Gui-Bin; Long, Wei; Li, Xiao-Dong; Xu, Guang-Yin; Lu, Ji-Xiang

    2017-01-01

    BACKGROUND To investigate the effect that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has on surgical decision making relative to video-electroencephalography (VEEG) and positron emission tomography-computed tomography (PET-CT), and if the differences in these variables translates to differences in surgical outcomes. MATERIAL AND METHODS A total of 166 children with epilepsy undergoing preoperative DCE-MRI, VEEG, and PET-CT examinations, surgical resection of epileptic foci, and intraoperative electrocorticography (ECoG) monitoring were enrolled. All children were followed up for 12 months and grouped by Engles prognostic classification for epilepsy. Based on intraoperative ECoG as gold standard, the diagnostic values of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and combined application of DCE-MRI, VEEG, and PET-CT in preoperative localization for epileptic foci were evaluated. RESULTS The sensitivity of DCE-MRI, VEEG, and PET-CT was 59.64%, 76.51%, and 93.98%, respectively; the accuracy of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, and DCE-MRI combined with PET-CT was 57.58%, 67.72%, 91.03%, 91.23%, and 96.49%, respectively. Localization accuracy rate of the combination of DCE-MRI, VEEG, and PET-CT was 98.25% (56/57), which was higher than that of DCE-MRI combined with VEEG and of DCE-MRI combined with PET-CT. No statistical difference was found in the accuracy rate of localization between these three combined techniques. During the 12-month follow-up, children were grouped into Engles grade I (n=106), II (n=31), III (n=21), and IV (n=8) according to postoperative conditions. CONCLUSIONS All DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and DCE-MRI combined with VEEG and PET-CT examinations have excellent accuracy in preoperative localization of epileptic foci and present excellent postoperative efficiency, suggesting that these combined imaging methods are suitable for serving as the

  16. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ishibashi, Masanori

    1997-01-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  17. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Masanori [Keio Univ., Tokyo (Japan). School of Medicine

    1997-11-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  18. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    International Nuclear Information System (INIS)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P.; Santana, Priscila C.

    2017-01-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  19. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P., E-mail: fernanda.stephaniebh@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Santana, Priscila C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  20. Differentiating intraparenchymal hemorrhage from contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients undergoing endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Payabvash, Seyedmehdi [Zeenat Qureshi Stroke Institute, Minneapolis, MN (United States); University of Minnesota, Department of Radiology, Minneapolis, MN (United States); Qureshi, Mushtaq H.; Khan, Shayaan M.; Khan, Mahnoor; Majidi, Shahram; Pawar, Swaroop; Qureshi, Adnan I. [Zeenat Qureshi Stroke Institute, Minneapolis, MN (United States)

    2014-09-15

    This study aimed to identify the imaging characteristics that can help differentiate intraparenchymal hemorrhage from benign contrast extravasation on post-procedural noncontrast CT scan in acute ischemic stroke patients after endovascular treatment. We reviewed the clinical and imaging records of all acute ischemic stroke patients who underwent endovascular treatment in two hospitals over a 3.5-year period. The immediate post-procedural CT scan was evaluated for the presence of hyperdense lesion(s). The average attenuation of the lesion(s) was measured. Intraparenchymal hemorrhage was defined as a persistent hyperdensity visualized on follow-up CT scan, 24 h or greater after the procedure. Of the 135 patients studied, 74 (55 %) patients had hyperdense lesion(s) on immediate post-procedural CT scan. Follow-up scans confirmed the diagnosis of intraparenchymal hemorrhage in 20 of these 74 patients. A receiver operating characteristic analysis showed that the average attenuation of the most hyperdense lesion can differentiate intraparenchymal hemorrhage from contrast extravasation with an area under the curve of 0.78 (p = 0.001). An average attenuation of <50 Hounsfield units (HU) in the most visually hyperattenuating hyperdense lesion had 100 % specificity and 56 % sensitivity for identification of contrast extravasations. Petechial hyperdensity was seen in 46/54 (85 %) patients with contrast extravasation versus 9/20 (45 %) patients with intraparenchymal hemorrhage on the immediate post-procedural CT scan (p < 0.001). An average attenuation <50 HU of the most hyperattenuating hyperdense parenchymal lesion on immediate post-procedural CT scan was very specific for differentiating contrast extravasation from intraparenchymal hemorrhage in acute ischemic stroke patients after endovascular treatment. (orig.)