WorldWideScience

Sample records for preliminary spectroscopic measurements

  1. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  2. Spectroscopic diagnostics and measurements at Jet

    International Nuclear Information System (INIS)

    Giannella, R.

    1994-01-01

    A concise review is presented of activity in the field spectroscopic diagnostic at JET during the latest few years. Together with a description of instruments, examples are given of the measurements conducted with these systems and some experimental result obtained with such activity are outlined. Emphasis is also given to the upgrading of existing apparatuses and the construction of new diagnostics ahead of the next experimental phase. 48 refs., 5 figs

  3. 4MOST: the 4-metre Multi-Object Spectroscopic Telescope project at preliminary design review

    NARCIS (Netherlands)

    de Jong, Roelof S.; Barden, Samuel C.; Bellido-Tirado, Olga; Brynnel, Joar G.; Frey, Steffen; Giannone, Domenico; Haynes, Roger; Johl, Diana; Phillips, Daniel; Schnurr, Olivier; Walcher, Jakob C.; Winkler, Roland; Ansorge, Wolfgang R.; Feltzing, Sofia; McMahon, Richard G.; Baker, Gabriella; Caillier, Patrick; Dwelly, Tom; Gaessler, Wolfgang; Iwert, Olaf; Mandel, Holger G.; Piskunov, Nikolai A.; Pragt, Johan H.; Walton, Nicholas A.; Bensby, Thomas; Bergemann, Maria; Chiappini, Cristina; Christlieb, Norbert; Cioni, Maria-Rosa L.; Driver, Simon; Finoguenov, Alexis; Helmi, Amina; Irwin, Michael J.; Kitaura, Francisco-Shu; Kneib, Jean-Paul; Liske, Jochen; Merloni, Andrea; Minchev, Ivan; Richard, Johan; Starkenburg, Else

    2016-01-01

    We present an overview of the 4MOST project at the Preliminary Design Review. 4MOST is a major new wide-field, high-multiplex spectroscopic survey facility under development for the VISTA telescope of ESO. 4MOST has a broad range of science goals ranging from Galactic Archaeology and stellar physics

  4. Spectroscopic analysis applied to temperature measurement in plasmas

    International Nuclear Information System (INIS)

    Fieffe-Prevost, P.

    1978-01-01

    The plasma temperature is defined only if the plasma is in a state near thermodynamic equilibrium. This plasma state is analysed in detail and spectroscopic methods for measuring the temperature are discussed. As an application the hydrogen arc of the National Institute of Metrology of the Conservatoire National des Arts et Metiers (Paris) is briefly described [fr

  5. Spectroscopic Measurements of Target Preheating on OMEGA

    International Nuclear Information System (INIS)

    Elton, R.C.; Griem, H.R.; Iglesias, E.J.

    2000-01-01

    The preheating of laser-heated microballoon targets has been measured by time-resolved x-ray and extreme ultraviolet (euv) spectroscopy on the 30 kJ, 351 nm, 60-beam laser-fusion system at the University of Rochester Laboratory for Laser Energetics. Thin coatings of aluminum overcoated with magnesium served as indicators. both the sequence of the x-ray line emission and the intensity of euv radiation were used to determine a preheating peaking at ∼ 10 ns prior to onset of the main laser pulse, with a power density ≅1% of the main pulse. The measurements are supported by numerical modeling. Further information is provided by absorption spectra from the aluminum coating, backlighted by continuum from the heated surface. The exact source of the preheating energy remains unknown at present, but most likely arrives from early laser leakage through the system. The present target diagnostic is particularly useful when all beams cannot be monitored directly at all laser wavelengths

  6. Transient full-field vibration measurement using spectroscopical stereo photogrammetry.

    Science.gov (United States)

    Yue, Kaiduan; Li, Zhongke; Zhang, Ming; Chen, Shan

    2010-12-20

    Contrasted with other vibration measurement methods, a novel spectroscopical photogrammetric approach is proposed. Two colored light filters and a CCD color camera are used to achieve the function of two traditional cameras. Then a new calibration method is presented. It focuses on the vibrating object rather than the camera and has the advantage of more accuracy than traditional camera calibration. The test results have shown an accuracy of 0.02 mm.

  7. Cosmic homogeneity: a spectroscopic and model-independent measurement

    Science.gov (United States)

    Gonçalves, R. S.; Carvalho, G. C.; Bengaly, C. A. P., Jr.; Carvalho, J. C.; Bernui, A.; Alcaniz, J. S.; Maartens, R.

    2018-03-01

    Cosmology relies on the Cosmological Principle, i.e. the hypothesis that the Universe is homogeneous and isotropic on large scales. This implies in particular that the counts of galaxies should approach a homogeneous scaling with volume at sufficiently large scales. Testing homogeneity is crucial to obtain a correct interpretation of the physical assumptions underlying the current cosmic acceleration and structure formation of the Universe. In this letter, we use the Baryon Oscillation Spectroscopic Survey to make the first spectroscopic and model-independent measurements of the angular homogeneity scale θh. Applying four statistical estimators, we show that the angular distribution of galaxies in the range 0.46 < z < 0.62 is consistent with homogeneity at large scales, and that θh varies with redshift, indicating a smoother Universe in the past. These results are in agreement with the foundations of the standard cosmological paradigm.

  8. SPECTROSCOPIC AND INTERFEROMETRIC MEASUREMENTS OF NINE K GIANT STARS

    Energy Technology Data Exchange (ETDEWEB)

    Baines, Ellyn K. [Remote Sensing Division, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375 (United States); Döllinger, Michaela P. [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Guenther, Eike W.; Hatzes, Artie P. [Thüringer Landessternwarte Tautenburg, Sternwarte 5, D-07778 Tautenburg (Germany); Hrudkovu, Marie [Isaac Newton Group of Telescopes, Apartado de Correos 321, E-387 00 Santa Cruz de la Palma, Canary Islands (Spain); Belle, Gerard T. van, E-mail: ellyn.baines@nrl.navy.mil [Lowell Observatory, Flagstaff, AZ 86001 (United States)

    2016-09-01

    We present spectroscopic and interferometric measurements for a sample of nine K giant stars. These targets are of particular interest because they are slated for stellar oscillation observations. Our improved parameters will directly translate into reduced errors in the final masses for these stars when interferometric radii and asteroseismic densities are combined. Here, we determine each star’s limb-darkened angular diameter, physical radius, luminosity, bolometric flux, effective temperature, surface gravity, metallicity, and mass. When we compare our interferometric and spectroscopic results, we find no systematic offsets in the diameters and the values generally agree within the errors. Our interferometric temperatures for seven of the nine stars are hotter than those determined from spectroscopy with an average difference of about 380 K.

  9. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  10. Zeff from spectroscopic bremsstrahlung measurements at ASDEX Upgrade and JET

    International Nuclear Information System (INIS)

    Meister, H.; Fischer, R.; Horton, L.D.; Maggi, C.F.; Nishijima, D.; Giroud, C.; Zastrow, K.-D.; Zaniol, B.

    2004-01-01

    The effective ionic charge Z eff is a means to assess the impurity content of a fusion plasma. It can be derived from measurements of bremsstrahlung intensity. These have been extended at ASDEX Upgrade by the usage of the sight lines for the charge exchange recombination diagnostic. Together with a previously installed sight line array, it is now possible to routinely determine the bremsstrahlung intensity over the whole minor radius purely from spectroscopic measurements. In a tokamak where the plasma facing components are made up of various materials, this is necessary to check if measurements are contaminated by line radiation. The bremsstrahlung background of the respective spectra is determined using Bayesian probability theory, giving consistent and improved error statistics. Using the information for electron temperature and density profiles, the Z eff profile is determined by an integrated method. The same approach to assess the Z eff profile has been demonstrated to be successful also at the JET tokamak

  11. Spectroscopic measurements of anode plasma with cryogenic pulsed ion sources

    International Nuclear Information System (INIS)

    Yoneda, H.; Urata, T.; Ohbayashi, K.; Kim, Y.; Horioka, K.; Kasuya, K.

    1987-01-01

    In ion beam diodes, electromagnetic wave is coupled to ion beam. Ion is extracted from anode plasma, which is produced early in the power pulse. However, exact mechanism of anode plasma production, expansion and ion extraction process is unknown. In particularly, anode plasma expansion is seemed to be one of the reasons of rapid impedance collapse of the diode, which is serious problem in high power experiments. Some experimental results showed that anode plasma expansion velocity was about 5 times larger than that inferred from simple thermal velocity. Several explanations for these results were proposed; for example, electron collisionarity in anode plasma, fast neutral gas particle, diamagnetism. To solve this question, it is necessary to measure the characteristic of anode plasma with space and time resolution. The authors made spectroscopic measurements to investigate variety of electron temperature, electron density, expansion velocity of anode plasma with various ion sources

  12. Development of a Neutron Spectroscopic System Utilizing Compressed Sensing Measurements

    Directory of Open Access Journals (Sweden)

    Vargas Danilo

    2016-01-01

    Full Text Available A new approach to neutron detection capable of gathering spectroscopic information has been demonstrated. The approach relies on an asymmetrical arrangement of materials, geometry, and an ability to change the orientation of the detector with respect to the neutron field. Measurements are used to unfold the energy characteristics of the neutron field using a new theoretical framework of compressed sensing. Recent theoretical results show that the number of multiplexed samples can be lower than the full number of traditional samples while providing the ability to have some super-resolution. Furthermore, the solution approach does not require a priori information or inclusion of physics models. Utilizing the MCNP code, a number of candidate detector geometries and materials were modeled. Simulations were carried out for a number of neutron energies and distributions with preselected orientations for the detector. The resulting matrix (A consists of n rows associated with orientation and m columns associated with energy and distribution where n < m. The library of known responses is used for new measurements Y (n × 1 and the solver is able to determine the system, Y = Ax where x is a sparse vector. Therefore, energy spectrum measurements are a combination of the energy distribution information of the identified elements of A. This approach allows for determination of neutron spectroscopic information using a single detector system with analog multiplexing. The analog multiplexing allows the use of a compressed sensing solution similar to approaches used in other areas of imaging. A single detector assembly provides improved flexibility and is expected to reduce uncertainty associated with current neutron spectroscopy measurement.

  13. Preliminary results from a high-pressure imaging spectroscopic proportional counter

    International Nuclear Information System (INIS)

    Hall, C.J.; Bazzano, A.; Lewis, R.A.; Parker, B.; Ubertini, P.; Worgan, J.S.

    1992-01-01

    A new type of high-pressure proportional counter, with both spatial resolution and spectroscopic capabilities is being jointly developed by the Istituto di Astrofisica Spaziale (CNR), Frascati, Italy and the SERC Daresbury Laboratory, Warrington, UK. The characteristics of the detector can be optimized for the particular requirement of the experiment, either for x-ray astronomy observations from space, or for the high count rate applications associated with a synchrotron light source. In its baseline configuration, the detector is filled to 5 bar with a xenon/quench gas mixture and will be sensitive over the energy range 5 keV to 150 keV (2.5 to 0.08 A). The positional resolution will range from 500 μm at the lower energies to around 1 mm at the higher end of the energy range. The current prototype has a sensitive area of 200x200 mm. The final version is hoped to have an area closer to 425x425 mm. The very small photon absorption length in the higher pressure gas allows the parallax effect, a feature of 1 atmosphere detectors, to be greatly reduced. The timing resolution (150 ns) of the detector enables both a high-rate capability and the possibility of the escape gate technique to achieve higher spectral resolution at energies > the Xe K edge. Preliminary results are presented showing the spectral and positional resolution for the prototype detector

  14. Optical constants of graphene measured by spectroscopic ellipsometry

    NARCIS (Netherlands)

    Weber, J.W.; Calado, V.E.; Van de Sanden, M.C.M.

    2010-01-01

    A mechanically exfoliated graphene flake ( ? 150×380??m2) on a silicon wafer with 98 nm silicon dioxide on top was scanned with a spectroscopic ellipsometer with a focused spot ( ? 100×55??m2) at an angle of 55°. The spectroscopic ellipsometric data were analyzed with an optical model in which the

  15. Optical constants of graphene measured by spectroscopic ellipsometry

    NARCIS (Netherlands)

    Weber, J.W.; Calado, V.E.; Sanden, van de M.C.M.

    2010-01-01

    A mechanically exfoliated graphene flake ( ~ 150×380 µm2) on a silicon wafer with 98 nm silicon dioxide on top was scanned with a spectroscopic ellipsometer with a focused spot ( ~ 100×55 µm2) at an angle of 55°. The spectroscopic ellipsometric data were analyzed with an optical model in which the

  16. Investigation and measures to noise on spectroscopic measurement system in JT-60U

    International Nuclear Information System (INIS)

    Nagaya, Susumu; Kubo, Hirotaka; Sugie, Tatsuo; Onizawa, Masami; Kawai, Isao; Nakata, Hisao.

    1997-11-01

    Breakdown of a negative-ion-based neutral beam injection (N-NBI) has caused noise trouble to several systems. The control circuit of a spectroscopic measurement system had not well worked because of the noise. The noise has been measured by an optical-fiber isolation system during operation of JT-60U. The amplitude and the frequency were 15-18 V and 15 MHz respectively. The transmission noise has been reduced by putting ferrite cores to all cables connecting with the control circuits. As a result, the trouble with the spectroscopic measurement system has completely been solved. Adding condensers and resistors to the circuit was not effective to reduce the noise. (author)

  17. Technical report for fabrication and performance test of electrochemical/spectroscopic measurement system

    International Nuclear Information System (INIS)

    Park, Yong Joon; Cho, Young Hwan; Bae, Sang Eun; Im, Hee Jung; Song, Kyu Seok

    2010-01-01

    Development of evaluation technology of electrochemical reactions is very essential to understand chemical behavior of actinides and lanthanides in molten salt media in relation to the development of Pyrochemical process. The on-line electrochemical/spectroscopic measurement system is to produce electrochemical parameters and thermodynamic parameters of actinides and lanthanides in molten salts by using spectroscopic techniques such as UV-VIS absorption as well as electrochemical in-situ measurement techniques. The on-line electrochemical/spectroscopic measurement system can be applied to understand the chemical reactions and oxidation states of actinides and lanthanides in molten salts eventually for the Pyrochemical process

  18. On-line data processing apparatus for spectroscopic measurements of atomic uranium

    International Nuclear Information System (INIS)

    Miron, E.; Levin, L.A.; Erez, G; Baumatz, D; Goren, I.; Shpancer, I.

    1977-01-01

    A computer-based apparatus for on-line spectroscopic measurements of atomic uranium is described. The system is capable of enhancing the signal-to-noise ratio by averaging, and performing calculations. Computation flow charts and programs are included

  19. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  20. X-ray imaging and spectroscopic measurements of implosions

    International Nuclear Information System (INIS)

    Hammel, B.A.; Ress, D.R.; Keane, C.J.; Kilkenny, J.D.; Landen, O.L.; Bell, P.; Pasha, R.; Wallace, R.J.; Bradley, D.K.

    1992-01-01

    Time-resolved x-ray measurements are essential in the investigation of laser-driven inertial confinement fusion, where neutron and x-ray emission are the only observable signatures of the compressed core conditions. High-speed detectors, available for x-ray measurement, provide a means of measuring the rapidly evolving conditions in imploding capsules on picosecond time scales. We address a wide range of issues in our indirectly driven implosion experiments on Nova, with a large variety of x-ray measurement techniques. Critical issues include symmetry of the compressed core, fuel density and temperature and hydrodynamic mix at the pusher/fuel interface

  1. Spectroscopic metrology for isotope composition measurements and transfer standards

    Science.gov (United States)

    Anyangwe Nwaboh, Javis; Balslev-Harder, David; Kääriäinen, Teemu; Richmond, Craig; Manninen, Albert; Mohn, Joachim; Kiseleva, Maria; Petersen, Jan C.; Werhahn, Olav; Ebert, Volker

    2017-04-01

    The World Meteorological Organization (WMO) has identified greenhouse gases such as CO2, CH4 and N2O as critical for global climate monitoring. Other molecules such as CO that has an indirect effect of enhancing global warming are also monitored. WMO has stated compatibility goals for atmospheric concentration and isotope ratio measurements of these gases, e.g. 0.1 ppm for CO2 concentration measurements in the northern hemisphere and 0.01 ‰ for δ13C-CO2. For measurements of the concentration of greenhouse gases, gas analysers are typically calibrated with static gas standards e.g. traceable to the WMO scale or to the International System of Units (SI) through a national metrology institute. However, concentrations of target components, e.g. CO, in static gas standards have been observed to drift, and typically the gas matrix as well as the isotopic composition of the target component does not always reflect field gas composition, leading to deviations of the analyser response, even after calibration. The deviations are dependent on the measurement technique. To address this issue, part of the HIGHGAS (Metrology for high-impact greenhouse gases) project [1] focused on the development of optical transfer standards (OTSs) for greenhouse gases, e.g. CO2 and CO, potentially complementing gas standards. Isotope ratio mass spectrometry (IRMS) [2] is currently used to provide state-of-the-art high precision (in the 0.01 ‰ range) measurements for the isotopic composition of greenhouse gases. However, there is a need for field-deployable techniques such as optical isotope ratio spectroscopy (OIRS) that can be combined with metrological measurement methods. Within the HIGHGAS project, OIRS methods and procedures based on e.g. cavity enhanced spectroscopy (CES) and tunable diode laser absorption spectroscopy (TDLAS), matched to metrological principles have been established for the measurement of 13C/12C and 18O/16O ratios in CO2, 15N/14N ratios in N2O, and 13C/12C and 2H

  2. Measuring FeO variation using astronomical spectroscopic observations

    Directory of Open Access Journals (Sweden)

    S. Unterguggenberger

    2017-03-01

    respectively. However, a comparison between the modelled O3 in the upper mesosphere and measurements of O3 made with the SABER satellite instrument suggests that these quantum yields may be a factor of ∼ 2 smaller.

  3. Spectroscopic measurements of an H- ion source discharge

    International Nuclear Information System (INIS)

    Keller, R.; Smith, H.V. Jr.

    1985-01-01

    Spectral emission lines from an H - Penning surface-plasma source (SPS), the 4X source, are examined in the visible and near ultraviolet. Electron distribution temperatures are deduced from integral line-strength measurements. These temperatures are surprisingly low, about 0.5 eV. Electron density values of about 1.5 x 10 14 cm -3 and H-atom energies between 2 and 2.6 eV are determined from the measured Balmer-line profiles. Assuming the H - energy is identical to the H-atom energy, an emittance limit of 0.006 π x cm x mrad is deduced for this source with a 5.4-mm aperture

  4. Spectroscopic and bolometric measurements of radiation loss in DIVA

    International Nuclear Information System (INIS)

    Shiho, Makoto; Odajima, Kazuo; Sugie, Tatsuo; Maeda, Hikosuke; Kasai, Satoshi

    1977-11-01

    Radiation loss due to low- and high-z impurities in DIVA (JFT-2a) was measured by means of a calibrated 3m grazing incidence vacuum monochromater and a calibrated pyroelectric detector. The following results were obtained: 1) Radiation loss power due to low-z impurities becomes insignificant by using clean surfaces for the vacuum wall. 2) Radiation loss power due to pseudo continuum from high-z impurities has influence on the energy balance of the confined plasma. 3) The divertor reduces the radiation loss by a factor of about 3. (auth.)

  5. Spectroscopic Measurements of Impurity Spectra on the EAST Tokamak

    International Nuclear Information System (INIS)

    Fu Jia; Li Yingying; Shi Yuejiang; Wang Fudi; Zhang Wei; Lv Bo; Huang Juan; Wan Baonian; Zhou Qian

    2012-01-01

    Ultraviolet (UV) and visible impurity spectra (200∼750 nm) are commonly used to study plasma and wall interactions in magnetic fusion plasmas. Two optical multi-channel analysis (OMA) systems have been installed for the UV-visible spectrum measurement on EAST. These two OMA systems are both equipped with the Czerny-Turner (C-T) type spectrometer. The upper vacuum vessel and inner divertor baffle can be viewed simultaneously through two optical lenses. The OMA1 system is mainly used for multi-impurity lines radiation measurement. A 280 nm wavelength range can be covered by a 300 mm focal length spectrometer equipped with a 300 grooves/mm grating. The Dα/Hα line shapes can be resolved by the OMA2 system. The focal length is 750 mm. The spectral resolution can be up to 0.01 nm using a 1800 grooves/mm grating. The impurity behaviour and hydrogen ratio evolution after boroniztion, lithium coating, and siliconization are compared. Lithium coating has shown beneficial effects on the reduction of edge recycling and low Z impurity (C, O) influx. The impurity expelling effect of the divertor configuration is also briefly discussed through multi-channels observation of OMA1 system. (magnetically confined plasma)

  6. Preliminary evaluation of the tibial tuberosity-trochlear groove measurement

    DEFF Research Database (Denmark)

    Miles, James Edward; Kirpensteijn, Jolle; Svalastoga, Eiliv Lars

    guide surgical treatment. The TTTG measures tibial tuberosity position relative to the axis of the femoral trochlea. A preliminary investigation of TTTG measurement was performed using the red fox (Vulpes vulpes) cadavers as a morphologically similar and homogenous substitute for dog cadavers. CT...

  7. Quantum chemical calculations and spectroscopic measurements of spectroscopic and thermodynamic properties of given uranyl complexes in aqueous solutions with possible environmental and industrial applications

    Directory of Open Access Journals (Sweden)

    Višňak Jakub

    2016-01-01

    Full Text Available A brief introduction into computational methodology and preliminary results for spectroscopic (excitation energies, vibrational frequencies in ground and excited electronic states and thermodynamic (stability constants, standard enthalpies and entropies of complexation reactions properties of some 1:1, 1:2 and 1:3 uranyl sulphato- and selenato- complexes in aqueos solutions will be given. The relativistic effects are included via Effective Core Potential (ECP, electron correlation via (TDDFT/B3LYP (dispersion interaction corrected and solvation is described via explicit inclusion of one hydration sphere beyond the coordinated water molecules. We acknowledge limits of this approximate description – more accurate calculations (ranging from semi-phenomenological two-component spin-orbit coupling up to four-component Dirac-Coulomb-Breit hamiltonian and Molecular Dynamics simulations are in preparation. The computational results are compared with the experimental results from Time-resolved Laser-induced Fluorescence Spectroscopy (TRLFS and UV-VIS spectroscopic studies (including our original experimental research on this topic. In case of the TRLFS and UV-VIS speciation studies, the problem of complex solution spectra decomposition into individual components is ill-conditioned and hints from theoretical chemistry could be very important. Qualitative agreement between our quantum chemical calculations of the spectroscopic properties and experimental data was achieved. Possible applications for geochemical modelling (e.g. safety studies of nuclear waste repositories, modelling of a future mining site and analytical chemical studies (including natural samples are discussed.

  8. A transuranic aerosol measurement system: Preliminary results

    International Nuclear Information System (INIS)

    Prevo, C.T.; Kaifer, R.C.; Rueppel, D.W.; Delvasto, R.M.; Biermann, A.H.; Phelps, P.L.

    1986-10-01

    We have completed the design, fabrication, and assembly of a computer-based prototype system for the measurement of transuranic aerosols in the workplace and environment. This system (called WOTAMS for Workplace Transuranic Aerosol Measurement System) incorporates two detectors: (1) an in-line solid-state alpha detector that sends out an alarm the moment a transuranic release occurs, and (2) an in-vacuum detector that increases off-line-analysis sensitivity. The in-line sensitivity of the system is better than 5.0 MPC-h, and the in-vacuum sensitivity exceeds 0.5 MPC-h. 5 refs., 8 figs., 1 tab

  9. Spectroscopic measurement of the electric field in a helium plasma jet

    NARCIS (Netherlands)

    Hofmans, M.; Sobota, A.

    2017-01-01

    The electric field in a plasma jet is measured spectroscopically utilizing the Stark-effect. A cold atmospheric pressure helium plasma jet is used, which operates at a μs-pulsed applied voltage of 6 kV, a frequency of 5 kHz and with a helium flow of 1.5 slm. Due to the electric field in the jet, the

  10. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    DEFF Research Database (Denmark)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1-200 bar and temperature range 300-1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients...... of a CO2-N2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated...

  11. Measurements of impurity spectra using UV/visible spectroscopic system in a GAMMA 10 plasma

    International Nuclear Information System (INIS)

    Matama, K.; Yoshikawa, M.; Kobayashi, T.; Kubota, Y.; Cho, T.

    2006-01-01

    Impurity spectra have been measured and identified using a newly designed ultraviolet and visible (UV/visible) spectroscopic system in the tandem mirror GAMMA 10. It is constructed using two spectrometers to obtain an entire wavelength range of UV/visible impurity spectra with a high wavelength resolution in one plasma shot. We successfully obtained the emission intensities of the radiation spectra in detail and information on the time-varying population densities of the impurities. We evaluate radiation loss from the GAMMA 10 plasma in the UV/visible range; further we estimate the electron density and temperature after applying the measured spectral intensity to a collisional-radiative model

  12. X-ray spectroscopic measurements of dielectronic recombination of highly charged krypton ions

    International Nuclear Information System (INIS)

    Biedermann, C.; Fuchs, T.; Liebisch, P.; Radtke, R.; Behar, E.; Doron, R.

    1999-01-01

    We have performed X-ray spectroscopic measurements of the dielectronic recombination (DR) resonance strengths for the KLn (n = 2, .., 5) series of He-, Li-, and Be-like krypton ions. The ions were produced with an electron beam ion trap, and the strengths were obtained from a fit procedure that compares the experimental excitation function for DR to theory. The results agree well with the predictions. By looking at the KLL resonance, the time evolution of different krypton charge states was measured with this technique and compared with a model of the trap inventory. (orig.)

  13. Spectroscopic measurements of soybeans used to parameterize physiological traits in the AgroIBIS ecosystem model

    Science.gov (United States)

    Singh, A.; Serbin, S.; Kucharik, C. J.; Townsend, P. A.

    2014-12-01

    Ecosystem models such AgroIBIS require detailed parameterizations of numerous vegetation traits related to leaf structure, biochemistry and photosynthetic capacity to properly assess plant carbon assimilation and yield response to environmental variability. In general, these traits are estimated from a limited number of field measurements or sourced from the literature, but rarely is the full observed range of variability in these traits utilized in modeling activities. In addition, pathogens and pests, such as the exotic soybean aphid (Aphis glycines), which affects photosynthetic pathways in soybean plants by feeding on phloem and sap, can potentially impact plant productivity and yields. Capturing plant responses to pest pressure in conjunction with environmental variability is of considerable interest to managers and the scientific community alike. In this research, we employed full-range (400-2500 nm) field and laboratory spectroscopy to rapidly characterize the leaf biochemical and physiological traits, namely foliar nitrogen, specific leaf area (SLA) and the maximum rate of RuBP carboxylation by the enzyme RuBisCo (Vcmax) in soybean plants, which experienced a broad range of environmental conditions and soybean aphid pressures. We utilized near-surface spectroscopic remote sensing measurements as a means to capture the spatial and temporal patterns of aphid impacts across broad aphid pressure levels. In addition, we used the spectroscopic data to generate a much larger dataset of key model parameters required by AgroIBIS than would be possible through traditional measurements of biochemistry and leaf-level gas exchange. The use of spectroscopic retrievals of soybean traits allowed us to better characterize the variability of plant responses associated with aphid pressure to more accurately model the likely impacts of soybean aphid on soybeans. Our next steps include the coupling of the information derived from our spectral measurements with the Agro

  14. SARDA HITL Preliminary Human Factors Measures and Analyses

    Science.gov (United States)

    Hyashi, Miwa; Dulchinos, Victoria

    2012-01-01

    Human factors data collected during the SARDA HITL Simulation Experiment include a variety of subjective measures, including the NASA TLX, questionnaire questions regarding situational awareness, advisory usefulness, UI usability, and controller trust. Preliminary analysis of the TLX data indicate that workload may not be adversely affected by use of the advisories, additionally, the controller's subjective ratings of the advisories may suggest acceptance of the tool.

  15. Model representations of kerogen structures: An insight from density functional theory calculations and spectroscopic measurements.

    Science.gov (United States)

    Weck, Philippe F; Kim, Eunja; Wang, Yifeng; Kruichak, Jessica N; Mills, Melissa M; Matteo, Edward N; Pellenq, Roland J-M

    2017-08-01

    Molecular structures of kerogen control hydrocarbon production in unconventional reservoirs. Significant progress has been made in developing model representations of various kerogen structures. These models have been widely used for the prediction of gas adsorption and migration in shale matrix. However, using density functional perturbation theory (DFPT) calculations and vibrational spectroscopic measurements, we here show that a large gap may still remain between the existing model representations and actual kerogen structures, therefore calling for new model development. Using DFPT, we calculated Fourier transform infrared (FTIR) spectra for six most widely used kerogen structure models. The computed spectra were then systematically compared to the FTIR absorption spectra collected for kerogen samples isolated from Mancos, Woodford and Marcellus formations representing a wide range of kerogen origin and maturation conditions. Limited agreement between the model predictions and the measurements highlights that the existing kerogen models may still miss some key features in structural representation. A combination of DFPT calculations with spectroscopic measurements may provide a useful diagnostic tool for assessing the adequacy of a proposed structural model as well as for future model development. This approach may eventually help develop comprehensive infrared (IR)-fingerprints for tracing kerogen evolution.

  16. The inductively coupled plasma as a source for the measurement of fundamental spectroscopic constants

    International Nuclear Information System (INIS)

    Farnsworth, P.B.

    1993-01-01

    Inductively coupled plasmas (ICPs) are stable, robust sources for the generation of spectra from neutral and singly ionized atoms. They are used extensively for analytical spectrometry, but have seen limited use for the measurement of fundamental spectroscopic constants. Several properties of the ICP affect its suitability for such fundamental measurements. They include: spatial structure, spectral background, noise characteristics, electron densities and temperatures, and the state of equilibrium in the plasma. These properties are particularly sensitive to the means by which foreign atoms are introduced into the plasma. With some departures from the operating procedures normally used in analytical measurements, the ICP promise to be a useful source for the measurement of fundamental atomic constants. (orig.)

  17. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    International Nuclear Information System (INIS)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander; Clausen, Sønnik

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1–200 bar and temperature range 300–1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients of a CO_2–N_2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated spectra, as well as published experimental data. - Highlights: • A ceramic gas cell designed for gas measurements up to 1300 K and 200 bar. • The first recorded absorption spectrum of CO_2 at 1000 K and 101 bar is presented. • Voigt profiles might suffice in the modeling of radiation from CO_2 in combustion.

  18. Confocal spectroscopic imaging measurements of depth dependent hydration dynamics in human skin in-vivo

    Science.gov (United States)

    Behm, P.; Hashemi, M.; Hoppe, S.; Wessel, S.; Hagens, R.; Jaspers, S.; Wenck, H.; Rübhausen, M.

    2017-11-01

    We present confocal spectroscopic imaging measurements applied to in-vivo studies to determine the depth dependent hydration profiles of human skin. The observed spectroscopic signal covers the spectral range from 810 nm to 2100 nm allowing to probe relevant absorption signals that can be associated with e.g. lipid and water-absorption bands. We employ a spectrally sensitive autofocus mechanism that allows an ultrafast focusing of the measurement spot on the skin and subsequently probes the evolution of the absorption bands as a function of depth. We determine the change of the water concentration in m%. The water concentration follows a sigmoidal behavior with an increase of the water content of about 70% within 5 μm in a depth of about 14 μm. We have applied our technique to study the hydration dynamics of skin before and after treatment with different concentrations of glycerol indicating that an increase of the glycerol concentration leads to an enhanced water concentration in the stratum corneum. Moreover, in contrast to traditional corneometry we have found that the application of Aluminium Chlorohydrate has no impact to the hydration of skin.

  19. Confocal spectroscopic imaging measurements of depth dependent hydration dynamics in human skin in-vivo

    Directory of Open Access Journals (Sweden)

    P. Behm

    2017-11-01

    Full Text Available We present confocal spectroscopic imaging measurements applied to in-vivo studies to determine the depth dependent hydration profiles of human skin. The observed spectroscopic signal covers the spectral range from 810 nm to 2100 nm allowing to probe relevant absorption signals that can be associated with e.g. lipid and water-absorption bands. We employ a spectrally sensitive autofocus mechanism that allows an ultrafast focusing of the measurement spot on the skin and subsequently probes the evolution of the absorption bands as a function of depth. We determine the change of the water concentration in m%. The water concentration follows a sigmoidal behavior with an increase of the water content of about 70% within 5 μm in a depth of about 14 μm. We have applied our technique to study the hydration dynamics of skin before and after treatment with different concentrations of glycerol indicating that an increase of the glycerol concentration leads to an enhanced water concentration in the stratum corneum. Moreover, in contrast to traditional corneometry we have found that the application of Aluminium Chlorohydrate has no impact to the hydration of skin.

  20. Spectroscopic measurements of plasma temperatures and electron number density in a uranium hollow cathode discharge lamp

    International Nuclear Information System (INIS)

    Shah, M.L.; Suri, B.M.; Gupta, G.P.

    2015-01-01

    The HCD (Hollow Cathode Discharge) lamps have been used as a source of free atoms of any metal, controllable by direct current in the lamp. The plasma parameters including neutral species temperature, atomic excitation temperature and electron number density in a see-through type, homemade uranium hollow cathode discharge lamp with neon as a buffer gas have been investigated using optical emission spectroscopic techniques. The neutral species temperature has been measured using the Doppler broadening of a neon atomic spectral line. The atomic excitation temperature has been measured using the Boltzmann plot method utilizing uranium atomic spectral lines. The electron number density has been determined from the Saha-Boltzmann equation utilizing uranium atomic and ionic spectral lines. To the best of our knowledge, all these three plasma parameters are simultaneously measured for the first time in a uranium hollow cathode discharge lamp

  1. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    International Nuclear Information System (INIS)

    Filippi, F.; Mostacci, A.; Palumbo, L.; Anania, M.P.; Biagioni, A.; Chiadroni, E.; Ferrario, M.; Cianchi, A.; Zigler, A.

    2016-01-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC-LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 10 16 –10 17  cm −3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  2. Spectroscopic measurements of plasma emission light for plasma-based acceleration experiments

    Science.gov (United States)

    Filippi, F.; Anania, M. P.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Mostacci, A.; Palumbo, L.; Zigler, A.

    2016-09-01

    Advanced particle accelerators are based on the excitation of large amplitude plasma waves driven by either electron or laser beams. Future experiments scheduled at the SPARC_LAB test facility aim to demonstrate the acceleration of high brightness electron beams through the so-called resonant Plasma Wakefield Acceleration scheme in which a train of electron bunches (drivers) resonantly excites wakefields into a preformed hydrogen plasma; the last bunch (witness) injected at the proper accelerating phase gains energy from the wake. The quality of the accelerated beam depends strongly on plasma density and its distribution along the acceleration length. The measurements of plasma density of the order of 1016-1017 cm-3 can be performed with spectroscopic measurements of the plasma-emitted light. The measured density distribution for hydrogen filled capillary discharge with both Balmer alpha and Balmer beta lines and shot-to-shot variation are here reported.

  3. Evaluating the influence of particulate matter on spectroscopic measurements of a combusting flow

    Science.gov (United States)

    Herlan, Jonathan; Murray, Nathan

    2017-11-01

    An adiabatic table-top burner has been used to develop a method for estimating the temperature and concentration of OH in a measurement volume of a non-premixed, hydrogen-air flame. The estimation method uses a nonlinear curve-fitting routine to compare experimental absorption spectra with a model derived, using statistical mechanics, from the Beer-Lambert law. With the aim of applying this method to the analysis of rocket exhaust plumes, this study evaluates whether or not it provides faithful estimates of temperature and OH concentration when the combusting flow contains particulate matter-such as soot or tracers used for particle image velocimetry (PIV) measurements. The hydrogen line of the table-top burner will be seeded with alumina, Al2O3, particles and their influence on spectroscopic measurements elucidated. The authors wish to thank Mr. Bernard Jansen for his support and insight in laboratory activities.

  4. Preliminary concepts for materials measurement and accounting in critical facilities

    International Nuclear Information System (INIS)

    Cobb, D.D.; Sapir, J.L.

    1978-01-01

    Preliminary concepts are presented for improved materials measurement and accounting in large critical facilities. These concepts will be developed as part of a study that will emphasize international safeguarding of critical facilities. The major safeguards problem is the timely verification of in-reactor inventory during periods of reactor operation. This will require a combination of measurement, statistical sampling, and data analysis techniques. Promising techniques include integral measurements of reactivity and other reactor parameters that are sensitive to the total fissile inventory, and nondestructive assay measurements of the fissile material in reactor fuel drawers and vault storage canisters coupled with statistical sampling plans tailored for the specific application. The effectiveness of proposed measurement and accounting strategies will be evaluated during the study

  5. Preliminary GRS Measurement of Chlorine Distribution on Surface of Mars

    Science.gov (United States)

    Keller, J. M.; Boynton, W. V.; Taylor, G. J.; Hamara, D.; Janes, D. M.; Kerry, K.

    2003-12-01

    Ongoing measurements with the Gamma Ray Spectrometer (GRS) aboard Mars Odyssey provide preliminary detection of chlorine at the surface of Mars. Summing all data since boom deployment and using a forward calculation model, we estimate values for chlorine concentration at 5° resolution. Rebinning this data and smoothing with a 15-degree-radius boxcar filter reveal regions of noticeable chlorine enrichment at scales larger than the original 5° resolution and allow for preliminary comparison with previous Mars datasets. Analyzing chlorine concentrations within 30 degrees of the equator, we find a negative correlation with thermal inertia (R2=0.55) and positive correlation with albedo (R2=0.52), indicating that chlorine is associated with fine, non-rock surface materials. Although possibly a smoothing artifact, the spatial correlation is more noticeable in the region covering Tharsis and Amazonis than around Arabia and Elysium. Additionally, a noticeable region of chlorine enrichment appears west of Tharsis Montes ( ˜0 to 20N, ˜110 to 150W) and chlorine concentration is estimated to vary in the equatorial region by over a factor of two. A simplified two-component model involving chlorine-poor rocks and a homogenous chlorine-rich fine material requires rock abundance to vary from zero to over 50%, a result inconsistent with previous measurements and models. In addition to variations in rock composition and distribution, substantial variations in chlorine content of various types of fine materials including dust, sand, and duricrust appear important in explaining this preliminary observation. Surprisingly, visual comparison of surface units mapped by Christensen and Moore (1992) does not show enrichment in chlorine associated with regions of indurated surfaces, where cementation has been proposed. Rather, Tharsis, a region of active deposition with proposed mantling of 0.1 to 2 meters of recent dust (Christensen 1986), shows the greatest chlorine signal. In light of

  6. Infrared spectroscopic measurement of skin hydration and sebum levels and comparison to corneometer and sebumeter

    Science.gov (United States)

    Ezerskaia, Anna; Pereira, S. F.; Urbach, H. P.; Varghese, Babu

    2016-05-01

    Skin health characterized by a system of water and lipids in Stratum Corneum provide protection from harmful external elements and prevent trans-epidermal water loss. Skin hydration (moisture) and sebum (skin surface lipids) are considered to be important factors in skin health; a right balance between these components is an indication of skin health and plays a central role in protecting and preserving skin integrity. In this manuscript we present an infrared spectroscopic method for simultaneous and quantitative measurement of skin hydration and sebum levels utilizing differential detection with three wavelengths 1720, 1750, and 1770 nm, corresponding to the lipid vibrational bands that lie "in between" the prominent water absorption bands. The skin sebum and hydration values on the forehead under natural conditions and its variations to external stimuli were measured using our experimental set-up. The experimental results obtained with the optical set-up show good correlation with the results obtained with the commercially available instruments Corneometer and Sebumeter.

  7. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    Energy Technology Data Exchange (ETDEWEB)

    Stuardo B, E. (Comision Chilena de Energia Nuclear, Santiago. Dept. de Aplicaciones Nucleares)

    1983-11-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 ..mu..R/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found.

  8. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    International Nuclear Information System (INIS)

    Stuardo B, E.

    1983-01-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 μR/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found. (Author)

  9. Optimized spectroscopic scheme for enhanced precision CO measurements with applications to urban source attribution

    Science.gov (United States)

    Nottrott, A.; Hoffnagle, J.; Farinas, A.; Rella, C.

    2014-12-01

    Carbon monoxide (CO) is an urban pollutant generated by internal combustion engines which contributes to the formation of ground level ozone (smog). CO is also an excellent tracer for emissions from mobile combustion sources. In this work we present an optimized spectroscopic sampling scheme that enables enhanced precision CO measurements. The scheme was implemented on the Picarro G2401 Cavity Ring-Down Spectroscopy (CRDS) analyzer which measures CO2, CO, CH4 and H2O at 0.2 Hz. The optimized scheme improved the raw precision of CO measurements by 40% from 5 ppb to 3 ppb. Correlations of measured CO2, CO, CH4 and H2O from an urban tower were partitioned by wind direction and combined with a concentration footprint model for source attribution. The application of a concentration footprint for source attribution has several advantages. The upwind extent of the concentration footprint for a given sensor is much larger than the flux footprint. Measurements of mean concentration at the sensor location can be used to estimate source strength from a concentration footprint, while measurements of the vertical concentration flux are necessary to determine source strength from the flux footprint. Direct measurement of vertical concentration flux requires high frequency temporal sampling and increases the cost and complexity of the measurement system.

  10. Preliminary Studies Of A Phase Modulation Technique For Measuring Chromaticity

    International Nuclear Information System (INIS)

    Tan, C.-Y.

    2006-01-01

    The classical method for measuring chromaticity is to slowly modulate the RF frequency and then measure the betatron tune excursion. The technique that is discussed in this paper instead modulates the phase of the RF and then the chromaticity is obtained by phase demodulating the betatron tune. This technique requires knowledge of the betatron frequency in real time in order for the phase to be demodulated. Fortunately, the Tevatron has a tune tracker based on the phase locked loop principle which fits this requirement. A preliminary study with this technique has showed that it is a promising method for doing continuous chromaticity measurement and raises the possibility of doing successful chromaticity feedback with it

  11. Optical properties of LiGaS2: an ab initio study and spectroscopic ellipsometry measurement

    International Nuclear Information System (INIS)

    Atuchin, V V; Lin, Z S; Isaenko, L I; Lobanov, S I; Kesler, V G; Kruchinin, V N

    2009-01-01

    Electronic and optical properties of lithium thiogallate crystal, LiGaS 2 , have been investigated by both experimental and theoretical methods. The plane-wave pseudopotential method based on DFT theory has been used for band structure calculations. The electronic parameters of Ga 3d orbitals have been corrected by the DFT+U methods to be consistent with those measured with x-ray photoemission spectroscopy. Evolution of optical constants of LiGaS 2 over a wide spectral range was determined by developed first-principles theory and dispersion curves were compared with optical parameters defined by spectroscopic ellipsometry in the photon energy range 1.2-5.0 eV. Good agreement has been achieved between theoretical and experimental results.

  12. Progress toward a microsecond duration, repetitive, intense-ion beam for active spectroscopic measurements on ITER

    International Nuclear Information System (INIS)

    Davis, H.A.; Bartsch, R.R.; Barnes, C.W.

    1996-01-01

    The authors describe the design of an intense, pulsed, repetitive, neutral beam based on magnetically insulated diode technology for injection into ITER for spectroscopic measurements of thermalizing alpha particle and thermal helium density profiles, ion temperature, plasma rotation, and low Z impurity concentrations in the confinement region. The beam is being developed to enhance low signal-to-noise ratios expected with conventional steady-state ion beams because of severe beam attenuation and intense bremstrahlung emission. A 5 GW (e.g., 100 keV, 50 kA) one-microsecond-duration beam would increase the signal by 10 3 compared to a conventional 5 MW beam with signal-to-noise ratios comparable to those from a chopped conventional beam in one second

  13. In vivo, noninvasive functional measurements of bone sarcoma using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Peterson, Hannah M.; Hoang, Bang H.; Geller, David; Yang, Rui; Gorlick, Richard; Berger, Jeremy; Tingling, Janet; Roth, Michael; Gill, Jonathon; Roblyer, Darren

    2017-12-01

    Diffuse optical spectroscopic imaging (DOSI) is an emerging near-infrared imaging technique that noninvasively measures quantitative functional information in thick tissue. This study aimed to assess the feasibility of using DOSI to measure optical contrast from bone sarcomas. These tumors are rare and pose technical and practical challenges for DOSI measurements due to the varied anatomic locations and tissue depths of presentation. Six subjects were enrolled in the study. One subject was unable to be measured due to tissue contact sensitivity. For the five remaining subjects, the signal-to-noise ratio, imaging depth, optical properties, and quantitative tissue concentrations of oxyhemoglobin, deoxyhemoglobin, water, and lipids from tumor and contralateral normal tissues were assessed. Statistical differences between tumor and contralateral normal tissue were found in chromophore concentrations and optical properties for four subjects. Low signal-to-noise was encountered during several subject's measurements, suggesting increased detector sensitivity will help to optimize DOSI for this patient population going forward. This study demonstrates that DOSI is capable of measuring optical properties and obtaining functional information in bone sarcomas. In the future, DOSI may provide a means to stratify treatment groups and monitor chemotherapy response for this disease.

  14. PRISM: Processing routines in IDL for spectroscopic measurements (installation manual and user's guide, version 1.0)

    Science.gov (United States)

    Kokaly, Raymond F.

    2011-01-01

    This report describes procedures for installing and using the U.S. Geological Survey Processing Routines in IDL for Spectroscopic Measurements (PRISM) software. PRISM provides a framework to conduct spectroscopic analysis of measurements made using laboratory, field, airborne, and space-based spectrometers. Using PRISM functions, the user can compare the spectra of materials of unknown composition with reference spectra of known materials. This spectroscopic analysis allows the composition of the material to be identified and characterized. Among its other functions, PRISM contains routines for the storage of spectra in database files, import/export of ENVI spectral libraries, importation of field spectra, correction of spectra to absolute reflectance, arithmetic operations on spectra, interactive continuum removal and comparison of spectral features, correction of imaging spectrometer data to ground-calibrated reflectance, and identification and mapping of materials using spectral feature-based analysis of reflectance data. This report provides step-by-step instructions for installing the PRISM software and running its functions.

  15. Preliminary development of a fiber optic sensor for measuring bilirubin.

    Science.gov (United States)

    Babin, Steven M; Sova, Raymond M

    2014-01-01

    Preliminary development of a fiber optic bilirubin sensor is described, where an unclad sensing portion is used to provide evanescent wave interaction of the transmitted light with the chemical environment. By using a wavelength corresponding to a bilirubin absorption peak, the Beer-Lambert Law can be used to relate the concentration of bilirubin surrounding the sensing portion to the amount of absorbed light. Initial testing in vitro suggests that the sensor response is consistent with the results of bulk absorption measurements as well as the Beer-Lambert Law. In addition, it is found that conjugated and unconjugated bilirubin have different peak absorption wavelengths, so that two optical frequencies may potentially be used to measure both types of bilirubin. Future development of this device could provide a means of real-time, point-of-care monitoring of intravenous bilirubin in critical care neonates with hyperbilirubinemia.

  16. Preliminary Development of a Fiber Optic Sensor for Measuring Bilirubin

    Directory of Open Access Journals (Sweden)

    Steven M. Babin

    2014-01-01

    Full Text Available Preliminary development of a fiber optic bilirubin sensor is described, where an unclad sensing portion is used to provide evanescent wave interaction of the transmitted light with the chemical environment. By using a wavelength corresponding to a bilirubin absorption peak, the Beer–Lambert Law can be used to relate the concentration of bilirubin surrounding the sensing portion to the amount of absorbed light. Initial testing in vitro suggests that the sensor response is consistent with the results of bulk absorption measurements as well as the Beer–Lambert Law. In addition, it is found that conjugated and unconjugated bilirubin have different peak absorption wavelengths, so that two optical frequencies may potentially be used to measure both types of bilirubin. Future development of this device could provide a means of real-time, point-of-care monitoring of intravenous bilirubin in critical care neonates with hyperbilirubinemia.

  17. Spectroscopic measurement of target plate erosion in the ASDEX Upgrade divertor

    Energy Technology Data Exchange (ETDEWEB)

    Filed, A R; Garcia-Rosales, C; Lieder, G; Pitcher, C S; Radtke, R [Association Euratom-Max-Planck-Institut fuer Plasmaphysik, Garching (Germany); ASDEX Upgrade Team

    1996-02-01

    The erosion of the graphite divertor plates in the ASDEX Upgrade tokamak is measured spectroscopically. Spatial profiles of the D{sup 0} and C{sup +} influxes across the outer target plate are determined from measured absolute line intensities. Plasma parameters (n{sub e}, T{sub e}) at the target, which are required to determine the appropriate photon emission efficiencies for these lines, are obtained from an in-vessel reciprocating Langmuir probe above the target plate. Yields for the erosion of the graphite by the incident D{sup +} flux are determined from the ratio of the measured C{sup +} to D{sup 0} fluxes. Over a range of moderate densities the measured yields of {<=} 4% are explicable in terms of physical sputtering alone. Chemical sputtering by low energy Franck-Condon neutrals probably contributes, however, to the total erosion. At higher densities detachment of the plasma from the targets occurs owing to formation of a MARFE near the X point. Under these conditions localized physical sputtering of the targets ceases. The impurity level (Z{sub eff}) is, however, maintained following detachment, indicating a corresponding maintenance of carbon influx, perhaps due to chemical erosion of the total graphite surface and/or an improvement in particle confinement in the detached state. (author). 26 refs, 14 figs, 1 tab.

  18. Preliminary Planck constant measurements via UME oscillating magnet Kibble balance

    Science.gov (United States)

    Ahmedov, H.; Babayiğit Aşkın, N.; Korutlu, B.; Orhan, R.

    2018-06-01

    The UME Kibble balance project was initiated in the second half of 2014. During this period we have studied the theoretical aspects of Kibble balances, in which an oscillating magnet generates AC Faraday’s voltage in a stationary coil, and constructed a trial version to implement this idea. The remarkable feature of this approach is that it can establish the link between the Planck constant and a macroscopic mass by one single experiment in the most natural way. Weak dependences on variations of environmental and experimental conditions, small size, and other useful features offered by this novel approach reduce the complexity of the experimental set-up. This paper describes the principles of the oscillating magnet Kibble balance and gives details of the preliminary Planck constant measurements. The value of the Planck constant determined with our apparatus is \\boldsymbol{h}/{{\\boldsymbol{h}}\\boldsymbol 90}={1}{.000} {004}~ , with a relative standard uncertainty of 6 ppm.

  19. Feasibility study of carbon particles injection by laser ablation to calibrate spectroscopic erosion measurements in Tore Supra

    International Nuclear Information System (INIS)

    Naiim Habib, M.; Mercadier, L.; Marandet, Y.; Delaporte, Ph.; Hernandez, C.; Grisolia, C.; Monier-Garbet, P.

    2011-01-01

    To check if spectroscopic measurements can be used for erosion determination, we propose to inject in the line of sight of the diagnostic, during plasma operation, a known carbon particle source, produced by laser ablation. A first assessment of this technique will be presented in the context of the Tore Supra tokamak.

  20. 2. Basis of measurement of plasma flow. 2.3 Plasma flow measurements. Spectroscopic methods

    International Nuclear Information System (INIS)

    Kado, Shinichiro

    2007-01-01

    The construction of optical system, optical fiber incident system, reciprocal linear dispersion, grating smile and astigmatism of the reflection plane diffraction grating spectrometer are explained in order to measure the plasma flow. The specification of flow measurement and evaluation of 0 point of velocity are stated. For examples of measurements, the fine structures of He II (Δn = 3 - 4) in material and plasma(MAP)-II of Tokyo University, plasma flow measurement by the charge exchange recombination spectroscopy using Large Helical Device and by Zeeman spectroscopy using TRIAM-1M tokamak plasma are stated. (S.Y.)

  1. Spectroscopic Measurements of the Ion Velocity Distribution at the Base of the Fast Solar Wind

    Science.gov (United States)

    Jeffrey, Natasha L. S.; Hahn, Michael; Savin, Daniel W.; Fletcher, Lyndsay

    2018-03-01

    In situ measurements of the fast solar wind reveal non-thermal distributions of electrons, protons, and minor ions extending from 0.3 au to the heliopause. The physical mechanisms responsible for these non-thermal properties and the location where these properties originate remain open questions. Here, we present spectroscopic evidence, from extreme ultraviolet spectroscopy, that the velocity distribution functions (VDFs) of minor ions are already non-Gaussian at the base of the fast solar wind in a coronal hole, at altitudes of thermal equilibrium, (b) fluid motions such as non-Gaussian turbulent fluctuations or non-uniform wave motions, or (c) some combination of both. These observations provide important empirical constraints for the source region of the fast solar wind and for the theoretical models of the different acceleration, heating, and energy deposition processes therein. To the best of our knowledge, this is the first time that the ion VDF in the fast solar wind has been probed so close to its source region. The findings are also a timely precursor to the upcoming 2018 launch of the Parker Solar Probe, which will provide the closest in situ measurements of the solar wind at approximately 0.04 au (8.5 solar radii).

  2. The BAT AGN Spectroscopic Survey (BASS) DR1-Spectral Measurements, Derived Quantities, and AGN Demographics

    Science.gov (United States)

    Koss, Michael; BASS Team

    2018-01-01

    We present the first catalog and data release of the Swift-BAT AGN Spectroscopic Survey (BASS). We analyze optical spectra of the majority of AGN (77%, 641/836) detected based on their 14-195 keV emission in the 70-month Swift BAT all-sky catalog. This includes redshift determination, absorption and emission line measurements, and black hole mass and accretion rate estimates for the majority of obscured and un-obscured AGN (74%, 473/641) with 340 measured for the first time. With ~90% of sources at z10^21.9 cm^-2. Seyfert 1.9 show a range of column densities. Compared to narrow line AGN in the SDSS, the X-ray selected AGN have a larger fraction of dusty host galaxies suggesting these types of AGN are missed in optical surveys. Using the most sensitive [OIII]/Hbeta and [NII]/Halpha emission line diagnostic, about half of the sources are classified as Seyferts, ~15% reside in dusty galaxies that lack an Hbeta detection, but for which the line upper limits imply either a Seyfert or LINER, ~15% are in galaxies with weak or no emission lines despite high quality spectra, and a few percent each are LINERS, composite galaxies, HII regions, or in known beamed AGN.

  3. Laser Cooling and Trapping of Neutral Strontium for Spectroscopic Measurements of Casimir-Polder Potentials

    Science.gov (United States)

    Cook, Eryn C.

    Casimir and Casimir-Polder effects are forces between electrically neutral bodies and particles in vacuum, arising entirely from quantum fluctuations. The modification to the vacuum electromagnetic-field modes imposed by the presence of any particle or surface can result in these mechanical forces, which are often the dominant interaction at small separations. These effects play an increasingly critical role in the operation of micro- and nano-mechanical systems as well as miniaturized atomic traps for precision sensors and quantum-information devices. Despite their fundamental importance, calculations present theoretical and numeric challenges, and precise atom-surface potential measurements are lacking in many geometric and distance regimes. The spectroscopic measurement of Casimir-Polder-induced energy level shifts in optical-lattice trapped atoms offers a new experimental method to probe atom-surface interactions. Strontium, the current front-runner among optical frequency metrology systems, has demonstrated characteristics ideal for such precision measurements. An alkaline earth atom possessing ultra-narrow intercombination transitions, strontium can be loaded into an optical lattice at the "magic" wavelength where the probe transition is unperturbed by the trap light. Translation of the lattice will permit controlled transport of tightly-confined atomic samples to well-calibrated atom-surface separations, while optical transition shifts serve as a direct probe of the Casimir-Polder potential. We have constructed a strontium magneto-optical trap (MOT) for future Casimir-Polder experiments. This thesis will describe the strontium apparatus, initial trap performance, and some details of the proposed measurement procedure.

  4. Modeling the effect of reflection from metallic walls on spectroscopic measurements

    International Nuclear Information System (INIS)

    Zastrow, K.-D.; Keatings, S. R.; O'Mullane, M. G.; Marot, L.; Temmerman, G. de

    2008-01-01

    A modification of JET is presently being prepared to bring operational experience with ITER-like first wall (Be) and divertor (W) materials, geometry and plasma parameters. Reflectivity measurements of JET sample tiles have been performed and the data are used within a simplified model of the JET and ITER vessels to predict additional contributions to quantitative spectroscopic measurements. The most general method to characterize reflectivity is the bidirectional reflection distribution function (BRDF). For extended sources however, such as bremsstrahlung and edge emission of fuel and intrinsic impurities, the results obtained in the modeling are almost as accurate if the total reflectivity with ideal Lambertian angular dependence is used. This is in contrast to the experience in other communities, such as optical design, lighting design, or rendering who deal mostly with pointlike light sources. This result is so far based on a very limited set of measurements and will be reassessed when more detailed BRDF measurements of JET tiles have been made. If it is true it offers the possibility of in situ monitoring of the reflectivity of selected parts of the wall during exposure to plasma operation, while remeasurement of the BRDF is performed during interventions. For a closed vessel structure such as ITER, it is important to consider multiple reflections. This makes it more important to represent the whole of the vessel reasonably accurately in the model, which on the other hand is easier to achieve than for the more complex internal structure of JET. In both cases the dominant contribution is from the first reflection, and a detailed model of the areas intersected by lines of sight of diagnostic interest is required.

  5. Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Mathiesen, Henrik Kahr; Tscherning, Thomas; Sorensen, Per Soelberg

    2005-01-01

    MR spectroscopy (MRS) provides information about neuronal loss or dysfunction by measuring decreases in N-acetyl aspartate (NAA), a metabolite widely believed to be a marker of neuronal viability. In multiple sclerosis (MS), whole-brain NAA (WBNAA) has been suggested as a marker of disease...... progression and treatment efficacy in treatment trials, and the ability to measure NAA loss in specific brain regions early in the evolution of this disease may have prognostic value. Most spectroscopic studies to date have been limited to single voxels or nonlocalized measurements of WBNAA only......, measurements of metabolites in specific brain areas chosen after image acquisition (e.g., normal-appearing white matter (NAWM), gray matter (GM), and lesions) can be obtained. The identification and exclusion of regions that are inadequate for spectroscopic evaluation in global assessments can significantly...

  6. Spectroscopic Measurements of the Far-Ultraviolet Dust Attenuation Curve at z ˜ 3

    Science.gov (United States)

    Reddy, Naveen A.; Steidel, Charles C.; Pettini, Max; Bogosavljević, Milan

    2016-09-01

    We present the first spectroscopic measurements of the shape of the far-ultraviolet (far-UV; λ =950{--}1500 Å) dust attenuation curve at high redshift (z˜ 3). Our analysis employs rest-frame UV spectra of 933 galaxies at z˜ 3, 121 of which have very deep spectroscopic observations (≳ 7 hr) at λ =850{--}1300 \\mathring{{A}} , with the Low Resolution Imaging Spectrograph on the Keck Telescope. By using an iterative approach in which we calculate the ratios of composite spectra in different bins of continuum color excess, E(B-V), we derive a dust curve that implies a lower attenuation in the far-UV for a given E(B-V) than those obtained with standard attenuation curves. We demonstrate that the UV composite spectra of z˜ 3 galaxies can be modeled well by assuming our new attenuation curve, a high covering fraction of H I, and absorption from the Lyman-Werner bands of {{{H}}}2 with a small (≲ 20 % ) covering fraction. The low covering fraction of {{{H}}}2 relative to that of the {{H}} {{I}} and dust suggests that most of the dust in the ISM of typical galaxies at z˜ 3 is unrelated to the catalysis of {{{H}}}2, and is associated with other phases of the ISM (I.e., the ionized and neutral gas). The far-UV dust curve implies a factor of ≈ 2 lower dust attenuation of Lyman continuum (ionizing) photons relative to those inferred from the most commonly assumed attenuation curves for L* galaxies at z˜ 3. Our results may be utilized to assess the degree to which ionizing photons are attenuated in H II regions or, more generally, in the ionized or low column density (N({{H}} {{I}})≲ {10}17.2 cm-2) neutral ISM of high-redshift galaxies. Based on data obtained at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and NASA, and was made possible by the generous financial support of the W.M. Keck Foundation.

  7. Spectroscopic measurements of lithium influx from an actively water-cooled liquid lithium limiter on FTU

    Energy Technology Data Exchange (ETDEWEB)

    Apruzzese, G.M., E-mail: gerarda.apruzzese@enea.it; Apicella, M.L.; Maddaluno, G.; Mazzitelli, G.; Viola, B.

    2017-04-15

    Since 2006, experiments using a liquid lithium limiter (LLL) were successfully performed on FTU, pointing out the problem of the quantity of lithium in the plasma, especially in conditions of strong evaporation due to the high temperature of limiter surface. In order to avoid the strong evaporation it is necessary to control the temperature by removing the heat from the limiter during the plasma exposure. To explore this issue a new actively cooled lithium limiter (CLL) has been installed and tested in FTU. Suitable monitors to detect the presence of lithium in the plasma are the spectroscopic diagnostics in the visible range that permit to measure the flux of lithium, coming from the limiter surface, through the brightness of the LiI spectral lines. For this aim an Optical Multichannel Analyser (OMA) spectrometer and a single wavelength impurities monitor have been used. The analysis of the Li influx signals has permitted to monitor the effects of interaction between the plasma and the limiter connected to the thermal load. Particular attention has been paid on the possible occurrence of sudden rise of the signals, which is an index of a strong interaction that could lead to a disruption. On the other hand, the appearance of significant signals gives useful indication if the interaction with the plasma has taken place.

  8. Scientific Considerations for Future Spectroscopic Measurements from Space of Activity on the Sun

    Science.gov (United States)

    Holman, Gordon D.

    2016-01-01

    High-resolution UV and X-ray spectroscopy are important to understanding the origin and evolution of magnetic energy release in the solar atmosphere, as well as the subsequent evolution of heated plasma and accelerated particles. Electromagnetic radiation is observed from plasma heated to temperatures ranging from about 10 k K to above 10 MK, from accelerated electrons emitting photons primarily at X-ray energies, and from ions emitting in gamma rays. These observations require space-based instruments sensitive to emissions at wavelengths shorter than the near UV. This article reviews some recent observations with emphasis on solar eruptive events, the models that describe them, and the measurements they indicate are needed for substantial progress in the future. Specific examples are discussed demonstrating that imaging spectroscopy with a cadence of seconds or better is needed to follow, understand, and predict the evolution of solar activity. Critical to substantial progress is the combination of a judicious choice of UV, EUV, and soft X-ray imaging spectroscopy sensitive to the evolution of this thermal plasma combined with hard X-ray imaging spectroscopy sensitive to suprathermal electrons. The major challenge will be to conceive instruments that, within the bounds of possible technologies and funding, have the flexibility and field of view to obtain spectroscopic observations where and when events occur while providing an optimum balance of dynamic range, spectral resolution and range, and spatial resolution.

  9. Spectroscopic measurement of the MHD dynamo in the MST reversed field pinch

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, James Tharp [Univ. of Wisconsin, Madison, WI (United States)

    1998-09-01

    The author has directly observed the coupling of ion velocity fluctuations and magnetic field fluctuations to produce an MHD dynamo electric field in the interior of the MST reversed field pinch. Chord averaged ion velocity fluctuations were measured with a fast spectroscopic diagnostic which collects line radiation from intrinsic carbon impurities simultaneously along two lines of sight. The chords employed for the measurements resolved long wavelength velocity fluctuations of several km/s at 8-20 kHz as tiny, fast Doppler shifts in the emitted line profile. During discrete dynamo events the velocity fluctuations, like the magnetic fluctuations, increase dramatically. The toroidal and poloidal chords with impact parameters of 0.3 a and 0.6 a respectively, resolved fluctuation wavenumbers with resonance surfaces near or along the lines of sight indicating a radial velocity fluctuation width for each mode which spans only a fraction of the plasma radius. The phase between the measured toroidal velocity fluctuations and the magnetic fluctuations matches the predictions of resistive MHD while the poloidal velocity fluctuations exhibit a phase consistent with the superposition of MHD effects and the advection of a mean flow gradient past the poloidal line of sight. Radial velocity fluctuations resolved by a chord through the center of the plasma were small compared to the poloidal and toroidal fluctuations and exhibited low coherence with the magnetic fluctuations. The ensembled nonlinear product of the ion velocity fluctuations and fluctuations in the magnetic field indicates a substantial dynamo electric field which peaks during the periods of spontaneous flux generation.

  10. Spectroscopic measurement of the MHD dynamo in the MST reversed field pinch

    International Nuclear Information System (INIS)

    Chapman, J.T.

    1998-09-01

    The author has directly observed the coupling of ion velocity fluctuations and magnetic field fluctuations to produce an MHD dynamo electric field in the interior of the MST reversed field pinch. Chord averaged ion velocity fluctuations were measured with a fast spectroscopic diagnostic which collects line radiation from intrinsic carbon impurities simultaneously along two lines of sight. The chords employed for the measurements resolved long wavelength velocity fluctuations of several km/s at 8--20 kHz as tiny, fast Doppler shifts in the emitted line profile. During discrete dynamo events the velocity fluctuations, like the magnetic fluctuations, increase dramatically. The toroidal and poloidal chords with impact parameters of 0.3 a and 0.6 a respectively, resolved fluctuation wavenumbers with resonance surfaces near or along the lines of sight indicating a radial velocity fluctuation width for each mode which spans only a fraction of the plasma radius. The phase between the measured toroidal velocity fluctuations and the magnetic fluctuations matches the predictions of resistive MHD while the poloidal velocity fluctuations exhibit a phase consistent with the superposition of MHD effects and the advection of a mean flow gradient past the poloidal line of sight. Radial velocity fluctuations resolved by a chord through the center of the plasma were small compared to the poloidal and toroidal fluctuations and exhibited low coherence with the magnetic fluctuations. The ensembled nonlinear product of the ion velocity fluctuations and fluctuations in the magnetic field indicates a substantial dynamo electric field which peaks during the periods of spontaneous flux generation

  11. Inter-laboratory comparisons of hexenuronic acid measurements in kraft eucalyptus pulps using a UV-Vis spectroscopic method

    Science.gov (United States)

    J.Y. Zhu; H.F Zhou; Chai X.S.; Donna Johannes; Richard Pope; Cristina Valls; M. Blanca Roncero

    2014-01-01

    An inter-laboratory comparison of a UV-Vis spectroscopic method (TAPPI T 282 om-13 “Hexeneuronic acid content of chemical pulp”) for hexeneuronic acid measurements was conducted using three eucalyptus kraft pulps. The pulp samples were produced in a laboratory at kappa numbers of approximately 14, 20, and 35. The hexeneuronic acid contents of the three pulps were...

  12. Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Mathiesen, Henrik Kahr; Tscherning, Thomas; Sorensen, Per Soelberg

    2005-01-01

    MR spectroscopy (MRS) provides information about neuronal loss or dysfunction by measuring decreases in N-acetyl aspartate (NAA), a metabolite widely believed to be a marker of neuronal viability. In multiple sclerosis (MS), whole-brain NAA (WBNAA) has been suggested as a marker of disease...... progression and treatment efficacy in treatment trials, and the ability to measure NAA loss in specific brain regions early in the evolution of this disease may have prognostic value. Most spectroscopic studies to date have been limited to single voxels or nonlocalized measurements of WBNAA only...

  13. Spectroscopic system for impurity measurements in the TJ-1 Tokamak of JEN

    International Nuclear Information System (INIS)

    Navas, G.; Zurro, B.

    1982-01-01

    we describe a spectroscopic system with spatial resolution capability that has been configured for plasma diagnostic in the TJ-1 Tokamak of JEN. The experimental system, based on a one meter monochromator, has been absolutely calibrated using a tungsten-halogen lamp. The calibration procedures and the absolute spectral sensitivity are presented as well as its dependence with the polarization. A simplified spectroscopic model of the radiation emitted by the intrinsic plasma impurities (C, 0, . . . ) has been developed. A one dimensional model of the temporal evolution of various ionization stages in coronal equilibrium is used to predict the electron temperature and impurity concentration. This model has been applied to experimental data from several Tokamaks. (Author) 23 refs

  14. Infrared spectroscopic measurement of skin hydration and sebum levels and comparison to corneometer and sebumeter

    OpenAIRE

    Ezerskaia, A.; Pereira, S.F.; Urbach, Paul; Varghese, Babu; Popp, Jürgen; Tuchin, Valery V.; Matthews, Dennis L.; Pavone, Francesco S.

    2016-01-01

    Skin health characterized by a system of water and lipids in Stratum Corneum provide protection from harmful external elements and prevent trans-epidermal water loss. Skin hydration (moisture) and sebum (skin surface lipids) are considered to be important factors in skin health; a right balance between these components is an indication of skin health and plays a central role in protecting and preserving skin integrity. In this manuscript we present an infrared spectroscopic method for simulta...

  15. Synthesis of selectively 13C-labelled benzoic acid for nuclear magnetic resonance spectroscopic measurement of glycine conjugation activity

    International Nuclear Information System (INIS)

    Akira, Kazuki; Hasegawa, Hiroshi; Baba, Shigeo

    1995-01-01

    The synthesis of [4- 13 C]benzoic acid (BA) labelled in a single protonated carbon, for use as a probe to measure glycine conjugation activity by nuclear magnetic resonance (NMR) spectroscopy, has been reported. The labelled compound was prepared by a seven-step synthetic scheme on a relatively small scale using [2- 13 C] acetone as the source of label in overall yield of 16%. The usefulness of [4- 13 C]BA was demonstrated by the NMR spectroscopic monitoring of urinary excretion of [4- 13 C]hippuric acid in the rat administered with the labelled BA. (Author)

  16. Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

    Science.gov (United States)

    Soller, Babs R.; Idwasi, Patrick O.; Balaguer, Jorge; Levin, Steven; Simsir, Sinan A.; Vander Salm, Thomas J.; Collette, Helen; Heard, Stephen O.

    2003-01-01

    OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and

  17. Soil sample moisture content as a function of time during oven drying for gamma-ray spectroscopic measurements

    International Nuclear Information System (INIS)

    Benke, R.R.; Kearfott, K.J.

    1999-01-01

    In routine gamma-ray spectroscopic analysis of collected soil samples, procedure often calls to remove soil moisture by oven drying overnight at a temperature of 100 deg. C . Oven drying not only minimizes the gamma-ray self-attenuation of soil samples due to the absence of water during the gamma-ray spectroscopic analysis, but also allows for a straightforward calculation of the specific activity of radionuclides in soil, historically based on the sample dry weight. Because radon exhalation is strongly dependent on moisture , knowledge of the oven-drying time dependence of the soil moisture content, combined with radon exhalation measurements during oven drying and at room temperature for varying soil moisture contents, would allow conclusions to be made on how the oven-drying radon exhalation rate depends on soil moisture content. Determinations of the oven-drying radon exhalation from soil samples allow corrections to be made for the immediate laboratory gamma-ray spectroscopy of radionuclides in the natural uranium decay chain. This paper presents the results of soil moisture content measurements during oven drying and suggests useful empirical fits to the moisture data

  18. Measurement of the ground state spectroscopic quadrupole moments of 191Os and 193Os

    International Nuclear Information System (INIS)

    Ernst, H.; Hagn, E.; Zech, E.

    1979-01-01

    Radioactive 191 Os and 193 Os nuclei have been aligned in an Os single crystal at temperatures down to 4 mK. From the temperature dependence of the γ-anisotropy the quadrupole frequencies vsub(Q) = e 2 qQ/h have been determined as vsub(Q)( 191 OsOs) = -278+-9 MHz and vsub(Q)( 193 OsOs) = -96+-15 MHz. With the known electric field gradient for OsOs of eq = (-4.54+-0.24) x 10 17 V/cm 2 the ground state spectroscopic quadrupole moments are deduced to be Q( 191 Os) = +2.53+-0.16 b and Q( 193 Os) = +0.87+-0.15 b. (orig.)

  19. A Peltier cooling diamond anvil cell for low-temperature Raman spectroscopic measurements

    Science.gov (United States)

    Noguchi, Naoki; Okuchi, Takuo

    2016-12-01

    A new cooling system using Peltier modules is presented for a low-temperature diamond anvil cell instrument. This cooling system has many advantages: it is vibration-free, low-cost, and compact. It consists of double-stacked Peltier modules and heat sinks, where a cooled ethylene glycol-water mixture flows through a chiller. Current is applied to the Peltier modules by two programmable DC power supplies. Sample temperature can be controlled within the range 210-300 K with a precision of ±0.1 K via a Proportional-Integral-Differential (PID) control loop. A Raman spectroscopic study for the H2O ice VII-VIII transition is shown as an example of an application of the Peltier cooling diamond anvil cell system.

  20. Spectroscopic measurements with a silicon drift detector having a continuous implanted drift cathode-voltage divider

    CERN Document Server

    Bonvicini, V; D'Acunto, L; Franck, D; Gregorio, A; Pihet, P; Rashevsky, A; Vacchi, A; Vinogradov, L I; Zampa, N

    2000-01-01

    A silicon drift detector (SDD) prototype where the drift electrode also plays the role of a high-voltage divider has been realised and characterised for spectroscopic applications at near-room temperatures. Among the advantages of this design, is the absence of metal on the sensitive surface which makes this detector interesting for soft X-rays. The detector prototype has a large sensitive area (2x130 mm sup 2) and the charge is collected by two anodes (butterfly-like detector). The energy resolution of a such a detector has been investigated at near-room temperatures using a commercial, hybrid, low-noise charge-sensitive preamplifier. The results obtained for the X-ray lines from sup 5 sup 5 Fe and sup 2 sup 4 sup 1 Am are presented.

  1. In vivo measurement of regional brain metabolic response to hyperventilation using magnetic resonance: proton echo planar spectroscopic imaging (PEPSI).

    Science.gov (United States)

    Posse, S; Dager, S R; Richards, T L; Yuan, C; Ogg, R; Artru, A A; Müller-Gärtner, H W; Hayes, C

    1997-06-01

    A new rapid spectroscopic imaging technique with improved sensitivity and lipid suppression, referred to as Proton Echo Planar Spectroscopic Imaging (PEPSI), has been developed to measure the 2-dimensional distribution of brain lactate increases during hyperventilation on a conventional clinical scanner equipped with a head surface coil phased array. PEPSI images (nominal voxel size: 1.125 cm3) in five healthy subjects from an axial section approximately 20 mm inferior to the intercommissural line were obtained during an 8.5-min baseline period of normocapnia and during the final 8.5 min of a 10-min period of capnometry-controlled hyperventilation (end-tidal PCO2 of 20 mmHg). The lactate/N-acetyl aspartate signal increased significantly from baseline during hyperventilation for the insular cortex, temporal cortex, and occipital regions of both the right and left hemisphere, but not in the basal ganglia. Regional or hemispheric right-to-left differences were not found. The study extends previous work using single-voxel MR spectroscopy to dynamically study hyperventilation effects on brain metabolism.

  2. Radionuclides measurements for the Phebus FP project - preliminary study

    International Nuclear Information System (INIS)

    Schuster, E.; Nopitsch, K.

    1989-09-01

    This report gives a review of proposed measurement techniques to measure quantitatively release and transport of fission products during and after fission product release tests. The measurement devices provided are for example gamma-spectrometers, scintillation counters and sampling vessels. The second part reviews the behaviour of fission product iodine under severe accident conditions and describes the iodine sampling system and the determination of iodine species in aqueous solutions

  3. Ibogaine: complex pharmacokinetics, concerns for safety, and preliminary efficacy measures.

    Science.gov (United States)

    Mash, D C; Kovera, C A; Pablo, J; Tyndale, R F; Ervin, F D; Williams, I C; Singleton, E G; Mayor, M

    2000-09-01

    Ibogaine is an indole alkaloid found in the roots of Tabernanthe Iboga (Apocynaceae family), a rain forest shrub that is native to western Africa. Ibogaine is used by indigenous peoples in low doses to combat fatigue, hunger and thirst, and in higher doses as a sacrament in religious rituals. Members of American and European addict self-help groups have claimed that ibogaine promotes long-term drug abstinence from addictive substances, including psychostimulants and opiates. Anecdotal reports attest that a single dose of ibogaine eliminates opiate withdrawal symptoms and reduces drug craving for extended periods of time. The purported efficacy of ibogaine for the treatment of drug dependence may be due in part to an active metabolite. The majority of ibogaine biotransformation proceeds via CYP2D6, including the O-demethylation of ibogaine to 12-hydroxyibogamine (noribogaine). Blood concentration-time effect profiles of ibogaine and noribogaine obtained for individual subjects after single oral dose administrations demonstrate complex pharmacokinetic profiles. Ibogaine has shown preliminary efficacy for opiate detoxification and for short-term stabilization of drug-dependent persons as they prepare to enter substance abuse treatment. We report here that ibogaine significantly decreased craving for cocaine and heroin during inpatient detoxification. Self-reports of depressive symptoms were also significantly lower after ibogaine treatment and at 30 days after program discharge. Because ibogaine is cleared rapidly from the blood, the beneficial aftereffects of the drug on craving and depressed mood may be related to the effects of noribogaine on the central nervous system.

  4. Stuttering generalization self-measure: Preliminary development of a self-measuring tool.

    Science.gov (United States)

    Alameer, Mohammad; Meteyard, Lotte; Ward, David

    2017-09-01

    Generalization of treatment is considered a difficult task for clinicians and people who stutter (PWS), and can constitute a barrier to long-term treatment success. To our knowledge, there are no standardized tests that collect measurement of the behavioral and cognitive aspects alongside the client's self-perception in real-life speaking situations. This paper describes the preliminary development of a Stuttering Generalization Self-Measure (SGSM). The purpose of SGSM is to assess 1) stuttering severity and 2) speech-anxiety level during real-life situations as perceived by PWS. Additionally, this measurement aims to 3) investigate correlations between stuttering severity and speech-anxiety level within the same real-life situation. The SGSM initially reported includes nine speaking situations designed that are developed to cover a variety of frequent speaking scenario situations. However, two of these were less commonly encountered by participants and subsequently not included in the final analyses. Items were created according to five listener categories (family and close friends, acquaintances, strangers, persons of authority, and giving a short speech to small audience). Forty-three participants (22 PWS, and 21 control) aged 18 to 53 years were asked to complete the assessment in real-life situations. Analyses indicated that test-retest reliability was high for both groups. Discriminant validity was also achieved as the SGSM scores significantly differed between the controls and PWS two groups for stuttering and speech-anxiety. Convergent validity was confirmed by significant correlations between the SGSM and other speech-related anxiety measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Spectroscopic and physicochemical measurements for on-line monitoring of used nuclear fuel separation processes

    Energy Technology Data Exchange (ETDEWEB)

    Nee, Ko; Nilsson, M. [Department of Chemical Engineering and Material Science, University of California, 916 Engineering Tower, Irvine, CA 92697-2575 (United States); Bryan, S.; Levitskaia, T. [Pacific Northwest National Laboratory, PO BOX 999, Richland, CA 99352 (United States)

    2013-07-01

    Separation processes for used nuclear fuel are often complicated and challenging due to the high constraints in purity of the products and safeguards of the process streams. In order to achieve a safe, secure and efficient separation process, the liquid streams in the separation process require close monitoring. Due to the high radiation environment, sampling of the materials is difficult. Availability of a detection technique that is remote, non-destructive and can avoid time-delay caused by retrieving samples would be beneficial and could minimize the exposure to personnel and provide material accountancy to avoid diversion (non-proliferation). For example, Ultra Violet (UV), Visible (Vis), Near-Infrared (NIR) and Raman spectroscopy that detect and quantify elements present in used nuclear fuel, e.g. lanthanides, actinides and molecules such as nitrate, can be used. In this work, we have carried out NIR and Raman spectroscopy to study aqueous solutions composed of different concentrations of nitric acid, sodium nitrate, and neodymium at varied temperatures. A chemometric model for online monitoring based on the PLS-Toolbox (MATLAB) software has been developed and validated to provide chemical composition of process streams based on spectroscopic data. In conclusion, both of our NIR and Raman spectra were useful for H{sup +} and NO{sub 3} prediction, and only NIR was helpful for the Nd{sup 3+} prediction.

  6. Optical properties of LiGaS{sub 2}: an ab initio study and spectroscopic ellipsometry measurement

    Energy Technology Data Exchange (ETDEWEB)

    Atuchin, V V [Laboratory of Optical Materials and Structures, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Lin, Z S [Beijing Center for Crystal R and D, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, PO Box 2711, Beijing 100190 (China); Isaenko, L I; Lobanov, S I [Laboratory of Crystal Growth, Institute of Geology and Mineralogy, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Kesler, V G [Laboratory of Physical Bases of Integrated Microelectronics, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation); Kruchinin, V N, E-mail: zslin@mail.ipc.ac.c [Laboratory for Ellipsometry of Semiconductor Materials and Structures, Institute of Semiconductor Physics, SB RAS, Novosibirsk 90, 630090 (Russian Federation)

    2009-11-11

    Electronic and optical properties of lithium thiogallate crystal, LiGaS{sub 2}, have been investigated by both experimental and theoretical methods. The plane-wave pseudopotential method based on DFT theory has been used for band structure calculations. The electronic parameters of Ga 3d orbitals have been corrected by the DFT+U methods to be consistent with those measured with x-ray photoemission spectroscopy. Evolution of optical constants of LiGaS{sub 2} over a wide spectral range was determined by developed first-principles theory and dispersion curves were compared with optical parameters defined by spectroscopic ellipsometry in the photon energy range 1.2-5.0 eV. Good agreement has been achieved between theoretical and experimental results.

  7. Optical constants of CH3NH3PbBr3 perovskite thin films measured by spectroscopic ellipsometry

    KAUST Repository

    Alias, Mohd Sharizal

    2016-07-14

    The lack of optical constants information for hybrid perovskite of CH3NH3PbBr3 in thin films form can delay the progress of efficient LED or laser demonstration. Here, we report on the optical constants (complex refractive index and dielectric function) of CH3NH3PbBr3 perovskite thin films using spectroscopic ellipsometry. Due to the existence of voids, the refractive index of the thin films is around 8% less than the single crystals counterpart. The energy bandgap is around 2.309 eV as obtained from photoluminescence and spectrophotometry spectra, and calculated from the SE analysis. The precise measurement of optical constants will be useful in designing optical devices using CH3NH3PbBr3 thin films.

  8. Hard X-Ray Flare Source Sizes Measured with the Ramaty High Energy Solar Spectroscopic Imager

    Science.gov (United States)

    Dennis, Brian R.; Pernak, Rick L.

    2009-01-01

    Ramaty High Energy Solar Spectroscopic Imager (RHESSI) observations of 18 double hard X-ray sources seen at energies above 25 keV are analyzed to determine the spatial extent of the most compact structures evident in each case. The following four image reconstruction algorithms were used: Clean, Pixon, and two routines using visibilities maximum entropy and forward fit (VFF). All have been adapted for this study to optimize their ability to provide reliable estimates of the sizes of the more compact sources. The source fluxes, sizes, and morphologies obtained with each method are cross-correlated and the similarities and disagreements are discussed. The full width at half-maximum (FWHM) of the major axes of the sources with assumed elliptical Gaussian shapes are generally well correlated between the four image reconstruction routines and vary between the RHESSI resolution limit of approximately 2" up to approximately 20" with most below 10". The FWHM of the minor axes are generally at or just above the RHESSI limit and hence should be considered as unresolved in most cases. The orientation angles of the elliptical sources are also well correlated. These results suggest that the elongated sources are generally aligned along a flare ribbon with the minor axis perpendicular to the ribbon. This is verified for the one flare in our list with coincident Transition Region and Coronal Explorer (TRACE) images. There is evidence for significant extra flux in many of the flares in addition to the two identified compact sources, thus rendering the VFF assumption of just two Gaussians inadequate. A more realistic approximation in many cases would be of two line sources with unresolved widths. Recommendations are given for optimizing the RHESSI imaging reconstruction process to ensure that the finest possible details of the source morphology become evident and that reliable estimates can be made of the source dimensions.

  9. Preliminary measurements on heat balance in pneumatic tires

    Science.gov (United States)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  10. Preliminary measurements with a 4 K gravitational wave antenna

    International Nuclear Information System (INIS)

    Boughn, S.P.; McAshan, M.S.; Paik, H.J.; Taber, R.C.; Fairbank, W.M.; Giffard, R.P.

    1975-01-01

    The behavior of a small resonant gravitational wave antenna cooled to 4 K has been measured. This antenna is the prototype for a much larger system designed to be cooled eventually below 10 mK. Noise levels have been observed in the fundamental mechanical mode of the antenna corresponding to temperatures below 50 K. The antenna is a 680 kg cylindrical bar of aluminum clad with a layer of 0.38 mm thick niobium-titanium. It is levitated on a magnetic field of 0.2 T provided by a set of curved superconducting coils. The helium tank is suspended by low resonant-frequency springs and acoustic isolation stacks constructed of alternate layers of rubber and iron. This suspension is mechanically independent of the rest of the cryostat. Measurements have shown that the magnetic levitation stage provides a further vibration attenuation in excess of 50 dB at the frequency of the antenna mode. When levitated at an exchange gas pressure of 0.01 Pa the energy decay time for the fundamental bar mode at 1312 Hz has been measured to be 40 s. This corresponds to a Q of 3.3 x 10 5 . For the experiments to be described the bar carries at one end an acceleration transducer, operating in a non-resonant mode. (Auth.)

  11. Preliminary Measures of Instructor Learning in Teaching Junctional Tourniquet Users.

    Science.gov (United States)

    Kragh, John F; Aden, James K; Shackelford, Stacy; Dubick, Michael A

    2016-01-01

    The objective of the present study was to assess the effect of instructor learning on student performance in use of junctional tourniquets. From a convenience sample of data available after another study, we used a manikin for assessment of control of bleeding from a right groin gunshot wound. Blood loss was measured by the instructor while training users. The data set represented a group of 30 persons taught one at a time. The first measure was a plot of mean blood loss volumes for the sequential users. The second measure was a plot of the cumulative sum (CUSUM) of mean blood loss (BL) volumes for users. Mean blood loss trended down as the instructor gained experience with each newly instructed user. User performance continually improved as the instructor gained more experience with teaching. No plateau effect was observed within the 30 users. The CUSUM plot illustrated a turning point or cusp at the seventh user. The prior portion of the plot (users 1-7) had the greatest improvement; performance did not improve as much thereafter. The improvement after the seventh user was the only change detected in the instructor's trend of performance. The instructor's teaching experience appeared to directly affect user performance; in a model of junctional hemorrhage, the volume of blood loss from the manikin during junctional tourniquet placement was a useful metric of instructor learning. The CUSUM technique detected a small but meaningful change in trend where the instructor learning curve was greatest while working with the first seven users. 2016.

  12. Results from preliminary FlowAct measurements during June 1995

    International Nuclear Information System (INIS)

    Linden, P.

    1997-02-01

    Flow measurements based on the pulsed neutron activation (PNA) method have been done and analysed. The results show that the accuracy of the PNA based FlowAct method is, under certain conditions, in the same range as the reference flow meter used. Also, the behaviour of the time distributions obtained is discussed, though the influence of velocity profile, radial mixing or other hydrodynamical questions is not taken into account. However, the objective of this work was to gain sufficient confidence in the method, and sufficient experience to be able to design and build a dedicated loop with stable flow and high-accuracy calibration. 4 refs, 12 figs

  13. Plasma flow velocity measurements using a modulated Michelson interferometer

    International Nuclear Information System (INIS)

    Howard, J.

    1997-01-01

    This paper discusses the possibility of flow velocity reconstruction using passive spectroscopic techniques. We report some preliminary measurements of the toroidal flow velocity of hydrogen atoms in the RTP tokamak using a phase modulated Michelson interferometer. (orig.)

  14. Measurements and modeling of 16O12C17O spectroscopic parameters at 2 μm

    Science.gov (United States)

    Jacquemart, David; Sung, Keeyoon; Coleman, Max; Crawford, Timothy; Brown, Linda R.; Mantz, Arlan W.; Smith, Mary Ann H.

    2017-12-01

    The lack of spectroscopic measurements for rare CO2 isotopologues was the main motivation of this work. In our present study we report line intensity measurements for 16O12C17O made with a high resolution Fourier transform spectrometer (Bruker IFS-125HR) and a 21 m path cryogenic Herriott cell at Jet Propulsion Laboratory. For this, a 17O-enriched CO2 gas sample was used, which comes as a mixture of primary and several minor CO2 isotopologues. The mole fraction of the 16O12C17O isotopologue in the mixture was determined to be 0.3991 by mass spectrometry from a Stable Isotope Ratio Mass Spectrometer (SIRMS) under stochastic distribution assumption at thermal equilibrium. Since the collisional narrowing effect was observed, the Rautian molecular line shape profile was systematically adopted instead of the Voigt profile. Absolute line positions were also investigated by performing a wavenumber calibration based on CO, HCl and a few well-known 16O12C16O transitions. Finally, around 1000 transitions were studied between 4604 and 5126 cm-1 involving 15 bands of the 16O12C17O isotopologue. All the measured line intensities were renormalized to be the values for 100% pure isotopologue sample. Transition dipole moments and Herman-Wallis factors were derived enabling a global comparison with theoretical calculations and predictions for the 15 bands of the 16O12C17O isotopologue. For the measured line positions, the absolute accuracy is around 2×10-4 cm-1. The accuracies of retrieved line intensities are 2 - 5% for five cold and two hot bands, and 6-30% for eight other weaker hot bands. Results from this work were in a good agreement with HITRAN 2012 for positions, but showed rather significant discrepancies for line intensities. An extensive line list was generated from new experimental measurements in order to improve and validate spectroscopic knowledge of 12C16O17O isotopologue in support of atmospheric remote sensing for the Earth (e.g., OCO-2 mission), Mars and Venus.

  15. M-line spectroscopic, spectroscopic ellipsometric and microscopic measurements of optical waveguides fabricated by MeV-energy N{sup +} ion irradiation for telecom applications

    Energy Technology Data Exchange (ETDEWEB)

    Bányász, I., E-mail: banyasz@sunserv.kfki.hu [Wigner Research Centre for Physics, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary); Berneschi, S. [“Enrico Fermi” Center for Study and Research, Piazza del Viminale 2, 00184 Roma (Italy); MDF-Lab, “Nello Carrara” Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Fried, M.; Lohner, T. [Institute of Technical Physics and Materials Science, Research Centre for Natural Sciences, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary); Conti, G. Nunzi; Righini, G.C.; Pelli, S. [MDF-Lab, “Nello Carrara” Institute of Applied Physics, IFAC-CNR, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Zolnai, Z. [Institute of Technical Physics and Materials Science, Research Centre for Natural Sciences, Hungarian Academy of Sciences, P.O.B. 49, H-1525, Budapest (Hungary)

    2013-08-31

    Irradiation with N{sup +} ions of the 1.5–3.5 MeV energy range was applied to optical waveguide formation. Planar and channel waveguides have been fabricated in an Er-doped tungsten–tellurite glass, and in both types of bismuth germanate (BGO) crystals: Bi{sub 4}Ge{sub 3}O{sub 12} (eulytine) and Bi{sub 12}GeO{sub 20} (sillenite). Multi-wavelength m-line spectroscopy and spectroscopic ellipsometry were used for the characterisation of the ion beam irradiated waveguides. Planar waveguides fabricated in the Er-doped tungsten–tellurite glass using irradiation with N{sup +} ions at 3.5 MeV worked even at the 1550 nm telecommunication wavelength. 3.5 MeV N{sup +} ion irradiated planar waveguides in eulytine-type BGO worked up to 1550 nm and those in sillenite-type BGO worked up to 1330 nm. - Highlights: ► Waveguides were fabricated in glass and crystals using MeV energy N{sup +} ions. ► SRIM simulation and spectroscopic ellipsometry yielded similar waveguide structures. ► Multi-wavelength m-line spectroscopy was used to study the waveguides. ► Waveguides fabricated in an Er-doped tungsten–tellurite glass worked up to 1.5 μm. ► Waveguides in Bi{sub 12}GeO{sub 20} remained operative up to 1.5 μm.

  16. APPLYING SPECTROSCOPIC METHODS ON ANALYSES OF HAZARDOUS WASTE

    OpenAIRE

    Dobrinić, Julijan; Kunić, Marija; Ciganj, Zlatko

    2000-01-01

    Abstract The paper presents results of measuring the content of heavy and other metals in waste samples from the hazardous waste disposal site of Sovjak near Rijeka. The preliminary design elaboration and the choice of the waste disposal sanification technology were preceded by the sampling and physico-chemical analyses of disposed waste, enabling its categorization. The following spectroscopic methods were applied on metal content analysis: Atomic absorption spectroscopy (AAS) and plas...

  17. Preliminary report on geophysical and mechanical borehole measurements at Stripa

    International Nuclear Information System (INIS)

    Nelson, P.; Paulsson, B.; Rachiele, R.; Andersson, L.; Schrauf, T.; Hustrulid, W.; Duran, O.; Magnusson, K.A.

    1979-05-01

    A suite of seven logs--neutron, gamma--gamma, resistivity, gamma ray, sonic, caliper, and temperature--operated in a borehole of 380-m depth located eleven zones where the rock permeability is expected to be enhanced due to the presence of open fractures. The sonic waveform record proved especially useful in this regard. Borehole measurements were also acquired in a large number of boreholes from 5- to 14-m length located in experimental drifts some 340-m underground. Here several physical properties, including the porosity, density, sonic velocity, and borehole rugosity, are generally quite uniform, with the exception of a few local chloritic zones and a few minor fractures. However, in situ determinations of the mechanical modulus with the CSM cell indicate substantial variability, with some apparent fracture control. Uranium and thorium concentrations are quite high in the Stripa granite, with local fluctuations associated with mineralogical changes as revealed by the gamma-ray log. A differential resistance probe appears promising as a sensitive detector of fine fracturing. A cross-hole ultrasonic system indicates variations of a few percent in compressional- and shear-wave velocities, reflecting the presence of fractures and changes in fracture characteristics as the rock is heated in a simulated storage test. The geophysical and mechanical data are being compared with the results from core and television logging, with hydrological test data on static pressure and injection permeability, and with displacements induced by thermal loading

  18. A preliminary approach to identify irradiated foods by thermoluminescence measurements

    International Nuclear Information System (INIS)

    Shin, Choonshik; Kim, Hyoung-Ook; Lim, Yoongho

    2012-01-01

    Thermoluminescence (TL) is one of the physical methods for the identification of irradiated foods. Among the currently developed methods, TL is the most widely used method for the identification of irradiated foods. However, in order to use this method, silicate minerals should be isolated from food samples. The process for the isolation of silicate minerals is time consuming and laborious. In this work, we have investigated the applicability of the TL method using iron-containing minerals instead of silicate minerals. In the TL analyses of dried spices, TL glow curves of iron-containing minerals showed maximum temperatures between 150 and 250 °C which were the same as those of silicate minerals. The process for the mineral separation of the proposed method is simple, fast, easy, and reliable. Moreover, the analysis results including TL ratio have not shown significant differences compared with the silicate minerals method. As a result, the TL measurements using the iron-containing minerals could be an excellent method for the identification of the irradiated foods, including dried spices. - Highlights: ► A thermoluminescence method using iron-containing minerals is proposed. ► Current method using silicate minerals is time consuming and laborious. ► However, the proposed method is simple, fast, easy, and reliable. ► Analysis results are similar to those of the silicate minerals method.

  19. Effect of radiative trapping on measurement of the spectroscopic properties of Yb sup 3 sup + :phosphate glasses

    CERN Document Server

    Dai Shi Xun; Wen Lei; Hu Li Li; Jiang Zhong Hon

    2003-01-01

    The effect of radiative trapping on measurement of the spectroscopic properties of Yb sup 3 sup + -doped phosphate glasses was investigated as a function of Yb sup 3 sup + concentration at different thicknesses. It was found that radiative trapping exists generally in Yb sup 3 sup + :phosphate glasses, even at low concentration. As a result, the measured lifetime of Yb sup 3 sup + in phosphate glasses is usually larger than the calculated one. The maximum discrepancies between them at high concentration are found to be <42%. The calculated lifetime should be used as a reference in determining the true value of the measured lifetime because of it being lengthened largely by radiative trapping. On the other hand, the shape of fluorescence spectrum exhibits remarkable changes due to the radiative trapping. What is more, the intensity increase of DELTA lambda sub e sub f sub f at high concentration is greater than that of low doping. The DELTA lambda sub e sub f sub f increases 36% from 53 to 72 nm with thickn...

  20. Electrochemical vs X-ray Spectroscopic Measurements of NiFe(CN)6 Crystals

    Science.gov (United States)

    Peecher, Benjamin; Hampton, Jennifer

    Pseudocapacitive materials like hexacyanoferrate have greater energy storage capabilities than standard capacitors while maintaining an ability to charge and discharge quickly. We modify the surface of an electrodeposited Ni thin film with a layer of hexacyanoferrate. Charging and discharging these modified films using cyclic voltammetry (CV) allows us to measure the electrochemically active Fe in the film. To determine how closely this resembles the full amount of Fe in the film, we measure the films' composition using particle-induced x-ray emission (PIXE). We also vary the amount of Ni deposited, both to compare the electrolysis value of charge deposited to the PIXE measurement of Ni in the film, and also to measure how varying the thickness of the Ni surface affects the presence of Fe in the film. Comparisons of the CV and PIXE measurements show agreement in Ni levels but disagreement in Fe levels. PIXE measurements of Fe in the film have positive correlation with Ni in the film. This correlation between PIXE measurements of Ni and Fe suggests that PIXE provides a reliable measure of Fe in the film. This implies that a variable proportion of total Fe in a given film is electrochemically active. This research was made possible by the Hope College Department of Physics Frissel Research Fund and the National Science Foundation under Grants RUI-DMR-1104725, MRI-CHE-0959282, and MRI/RUI-PHY-0319523.

  1. Simulation of a method for determining one-dimensional {sup 137}Cs distribution using multiple gamma spectroscopic measurements with an adjustable cylindrical collimator and center shield

    Energy Technology Data Exchange (ETDEWEB)

    Whetstone, Z.D.; Dewey, S.C. [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States); Kearfott, K.J., E-mail: kearfott@umich.ed [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States)

    2011-05-15

    With multiple in situ gamma spectroscopic measurements obtained with an adjustable cylindrical collimator and a circular shield, the arbitrary one-dimensional distribution of radioactive material can be determined. The detector responses are theoretically calculated, field measurements obtained, and a system of equations relating detector response to measurement geometry and activity distribution solved to estimate the distribution. This paper demonstrates the method by simulating multiple scenarios and providing analysis of the system conditioning.

  2. VUV spectroscopic measurement in current drive experiments in TRIAM-1M

    International Nuclear Information System (INIS)

    Hara, Shigemitsu; Kawasaki, Shoji; Jotaki, Eriko; Moriyama, Shin-ichi; Nagao, Akihiro; Nakamura, Kazuo; Nakamura, Yukio; Hiraki, Naoji; Itoh, Satoshi

    1991-01-01

    VUV spectrum and time evolution of line intensity were measured. Steady-state transport equation was solved numerically, and the solution was qualitatively compared with the experimental results. (author)

  3. Spectroscopic measurements of the density and electronic temperature at the plasma edge in Tore Supra

    International Nuclear Information System (INIS)

    Lediankine, A.

    1996-01-01

    The profiles of temperature and electronic density at the plasma edge are important to study the wall-plasma interaction and the radiative layers in the Tokamak plasmas. The laser ablation technique of the lithium allows to measure the profile of electronic density. To measure the profile of temperature, it has been used for the first time, the injection of a fluorine neutral atoms beam. The experiments, the results are described in this work. (N.C.)

  4. X ray and EUV spectroscopic measurements of highly charged tungsten ions relevant to fusion plasmas

    International Nuclear Information System (INIS)

    Radtke, R; Biedermann, C; Mandelbaum, P; Schwob, J L

    2007-01-01

    Using high-resolution x ray and extreme ultraviolet (EUV) spectrometry, the line emission of W 28+ - W 50+ ions was measured at the Berlin Electron Beam Ion Trap (EBIT). Our study encompasses a wide range of wavelengths (5-800 A) and includes the observation of electric and magnetic dipole lines. The results of our measurements are compared with predicted transition wavelengths from ab initioatomic structure calculations

  5. Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

    Science.gov (United States)

    Bivolaru, Daniel; Lee, Joseph W.; Jones, Stephen B.; Tedder, Sarah A.; Danehy, Paul M.; Weikl, M. C.; Magnotti, G.; Cutler, Andrew D.

    2007-01-01

    This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

  6. Noninvasive measurements of cardiac high-energy phosphate metabolites in dilated cardiomyopathy by using 31P spectroscopic chemical shift imaging

    International Nuclear Information System (INIS)

    Hansch, A.; Rzanny, R.; Heyne, J.-P.; Reichenbach, J.R.; Kaiser, W.A.; Leder, U.

    2005-01-01

    Dilated cardiomyopathy (DCM) is accompanied by an impaired cardiac energy metabolism. The aim of this study was to investigate metabolic ratios in patients with DCM compared to controls by using spectroscopic two-dimensional chemical shift imaging (2D-CSI). Twenty volunteers and 15 patients with severe symptoms (left ventricular ejection fraction, LVEF 30%) of DCM were investigated. Cardiac 31 P MR 2D-CSI measurements (voxel size: 40 x 40 x 100 mm 3 ) were performed with a 1.5 T whole-body scanner. Measurement time ranged from 15 min to 30 min. Peak areas and ratios of different metabolites were evaluated, including high-energy phosphates (PCr, ATP), 2,3-diphosphoglycerate (2,3-DPG) and phosphodiesters (PDE). In addition, we evaluated how PCr/ATP ratios correlate with LVEF as an established prognostic factor of heart failure. The PCr/γ-ATP ratio was significantly decreased in patients with moderate and severe DCM and showed a linear correlation with reduced LVEFs. PDE/ATP ratios were significantly increased only in patients with severe DCM as compared to volunteers. Applying 31 P MRS with commonly-available 2D-CSI sequences is a valuable technique to evaluate DCM by determining PCr/ATP ratios noninvasively. In addition to reduced PCr/ATP ratios observed in patients suffering from DCM, significantly-increased PDE/ATP ratios were found in patients with severe DCM. (orig.)

  7. PSYCHE CPMG-HSQMBC: An NMR Spectroscopic Method for Precise and Simple Measurement of Long-Range Heteronuclear Coupling Constants.

    Science.gov (United States)

    Timári, István; Szilágyi, László; Kövér, Katalin E

    2015-09-28

    Among the NMR spectroscopic parameters, long-range heteronuclear coupling constants convey invaluable information on torsion angles relevant to glycosidic linkages of carbohydrates. A broadband homonuclear decoupled PSYCHE CPMG-HSQMBC method for the precise and direct measurement of multiple-bond heteronuclear couplings is presented. The PSYCHE scheme built into the pulse sequence efficiently eliminates unwanted proton-proton splittings from the heteronuclear multiplets so that the desired heteronuclear couplings can be determined simply by measuring frequency differences between peak maxima of pure antiphase doublets. Moreover, PSYCHE CPMG-HSQMBC can provide significant improvement in sensitivity as compared to an earlier Zangger-Sterk-based method. Applications of the proposed pulse sequence are demonstrated for the extraction of (n)J((1)H,(77)Se) and (n)J((1)H,(13)C) values, respectively, in carbohydrates; further extensions can be envisioned in any J-based structural and conformational studies. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. The impact of hydration changes in fresh bio-tissue on THz spectroscopic measurements

    International Nuclear Information System (INIS)

    Png, G M; Ng, B W-H; Mickan, S P; Abbott, D; Choi, J W; Zhang, X-C

    2008-01-01

    We present a study of how residual hydration in fresh rat tissue samples can vastly alter their extracted terahertz (THz) optical properties and influence their health assessment. Fresh (as opposed to preserved) tissue most closely mimics in vivo conditions, but high water content creates many challenges for tissue handling and THz measurement. Our THz measurements of fresh tissue over time highlight the effect of tissue hydration on tissue texture and dimension, the latter directly influencing the accuracy of calculated optical properties. We then introduce lyophilization (freeze drying) as a viable solution for overcoming hydration and freshness problems. Lyophilization removes large amounts of water while retaining sample freshness. In addition, lyophilized tissue samples are easy to handle and their textures and dimensions do not vary over time, allowing for consistent and stable THz measurements. A comparison of lyophilized and fresh tissue shows for the first time that freeze drying may be one way of overcoming tissue hydration issues while preserving tissue cellular structure. Finally, we compare THz measurements from fresh tissue against necrotic tissue to verify freshness over time. Indeed, THz measurements from fresh and necrotic tissues show marked differences

  9. Spectroscopic Measurements of Planar Foil Plasmas Driven by a MA LTD

    Science.gov (United States)

    Patel, Sonal; Yager-Elorriaga, David; Steiner, Adam; Jordan, Nick; Gilgenbach, Ronald; Lau, Y. Y.

    2014-10-01

    Planar foil ablation experiments are being conducted on the Linear Transformer Driver (LTD) at the University of Michigan. The experiment consists of a 400 nm-thick, Al planar foil and a current return post. An optical fiber is placed perpendicular to the magnetic field and linear polarizers are used to isolate the pi and sigma lines. The LTD is charged to +/-70 kV with approximately 400-500 kA passing through the foil. Laser shadowgraphy has previously imaged the plasma and measured anisotropy in the Magneto Rayleigh-Taylor (MRT) instability. Localized magnetic field measurements using Zeeman splitting during the current rise is expected to yield some insight into this anisotropy. Initial experiments use Na D lines of Al foils seeded with sodium to measure Zeeman splitting. Several ion lines are also currently being studied, such as Al III and C IV, to probe the higher temperature core plasma. In planned experiments, several lens-coupled optical fibers will be placed across the foil, and local magnetic field measurements will be taken to measure current division within the plasma. This work was supported by US DoE. S.G. Patel and A.M. Steiner supported by NPSC funded by Sandia. D.A. Yager supported by NSF fellowship Grant DGE 1256260.

  10. The retrieval of profile and chemical information from ground-based UV-visible spectroscopic measurements

    International Nuclear Information System (INIS)

    Schofield, R.; Connor, B.J.; Kreher, K.; Johnston, P.V.; Rodgers, C.D.

    2004-01-01

    An algorithm has been developed to retrieve altitude information at different diurnal stages for trace gas species by combining direct-sun and zenith-sky UV-visible differential slant column density (DSCD) measurements. DSCDs are derived here using differential optical absorption spectroscopy. Combining the complementary zenith-sky measurements (sensitive to the stratosphere) with direct-sun measurements (sensitive to the troposphere) allows this vertical distinction. Trace gas species such as BrO and NO 2 have vertical profiles with strong diurnal dependence. Information about the diurnal variation is simultaneously retrieved with the altitude distribution of the trace gas. The retrieval is a formal optimal estimation profile retrieval, allowing a complete assessment of information content and errors

  11. Upconversion in Nd3+-doped glasses: Microscopic theory and spectroscopic measurements

    International Nuclear Information System (INIS)

    Oliveira, S. L.; Sousa, D. F. de; Andrade, A. A.; Nunes, L. A. O.; Catunda, T.

    2008-01-01

    In this work, we report a systematic investigation of upconversion losses and their effects on fluorescence quantum efficiency and fractional thermal loading in Nd 3+ -doped fluoride glasses. The energy transfer upconversion (γ up ) parameter, which describes upconversion losses, was experimentally determined using different methods: thermal lens (TL) technique and steady state luminescence (SSL) measurements. Additionally, the upconversion parameter was also obtained from energy transfer models and excited state absorption measurements. The results reveal that the microscopic treatment provided by the energy transfer models is similar to the macroscopic ones achieved from the TL and SSL measurements because similar γ up parameters were obtained. Besides, the achieved results also point out the migration-assisted energy transfer according to diffusion-limited regime rather than hopping regime as responsible for the upconversion losses in Nd-doped glasses

  12. On-line nuclear half life and spectroscopic measurements on mass-separated fission product nuclei

    International Nuclear Information System (INIS)

    McDonald, J.; Fogelberg, B.; Baecklin, A.

    1979-01-01

    A description is given of the methods and equipment employed for nuclear spectroscopy studies of short lived fission product nuclei at the OSIRIS ISOL facility in Studsvik, Sweden. Furthermore a table of new nuclear half-lives measured with this equipment is presented. (author)

  13. Spectroscopic measurement of 204Pb isotope shift and 205Pb nuclear spin

    International Nuclear Information System (INIS)

    Schonberger, P.

    1984-01-01

    The isotope shift of 204 Pb and the nuclear spin of 1.4 X 10 7 -y 205 Pb was determined from a high-resolution optical measurement of the 6p 23 P 0 -6p7s 3 P 1 0 283.3-nm resonance line. The value of the shift, relative to 208 Pb is -140.2(8) x 10 -3 cm -1 , the negative sign indicating a shift to lower wave numbers. The precision is 3-4 times greater than that of previous measurements. The spin of 205 Pb I = 5/2 was obtained from the measurement of the relative intensities of its three hyperfine components. This method of absorption spectroscopy determination of ground state nuclear spin is applicable to any stable or long-lived isotope. High resolution optical absorption spectra were obtained with a 25.4 cm diffraction grating in a 9.1 m focal length Czerny-Turner spectrometer. A signal-averaging scanning technique was used to record the spectra. Increased precision in the isotope shift measurement was attained by using separated isotope samples of 204 Pb and 207 Pb

  14. Spectroscopic Measurement of LEAD-204 Isotope Shift and LEAD-205 Nuclear Spin.

    Science.gov (United States)

    Schonberger, Peter

    The isotope shift of ('204)Pb and the nuclear spin of 1.4 x 10('7)-y ('205)Pb was determined from a high -resolution optical measurement of the 6p('2) ('3)P(,o) -6p7s('3)P(,1)('o) 283.3-nm resonance line. The value of the shift, relative to ('208)Pb is -140.2(8) x 10('-3)cm(' -1), the negative sign indicating a shift to lower wave numbers. The precision is 3-4 times greater than that of previous measurements. The spin of ('205)Pb l = 5/2 was obtained from the measurement of the relative intensities of its three hyperfine components. This method of absorption spectroscopy determination of ground state nuclear spin is applicable to any stable or longlived isotope. High resolution optical absorption spectra were obtained with a 25.4cm diffraction grating in a 9.1m focal length Czerny-Turner spectrometer. A signal-averaging scanning technique was used to record the spectra. Increased precision in the isotope shift measurement was attained by using separated isotope samples of ('204)Pb and ('207)Pb. A controlled amount of the later was incorporated in the absorption cell to provide internal calibration by its 6p7s ('3)P(,1)('o) hfs separation. Absorption spectra were recorded for several optical thicknesses of the absorber. A single spin value of increased precision was derived from the entire set of combined data.

  15. Performance Evaluation of Spectroscopic Detectors for LEU Hold-up Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ramkumar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nutter, Greg [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-12-06

    The hold-up measurement of low-enriched uranium materials may require use of alternate detector types relative to the measurement of highly enriched uranium. This is in part due to the difference in process scale (i.e., the components are generally larger for low-enriched uranium systems), but also because the characteristic gamma-ray lines from 235U used for assay of highly enriched uranium will be present at a much reduced intensity (on a per gram of uranium basis) at lower enrichments. Researchers at Oak Ridge National Laboratory examined the performance of several standard detector types, e.g., NaI(Tl), LaBr3(Ce), and HPGe, to select a suitable candidate for measuring and quantifying low-enriched uranium hold-up in process pipes and equipment at the Portsmouth gaseous diffusion plant. Detector characteristics, such as energy resolution (full width at half maximum) and net peak count rates at gamma ray energies spanning a range of 60–1332 keV, were measured for the above-mentioned detector types using the same sources and in the same geometry. Uranium enrichment standards (Certified Reference Material no. 969 and Certified Reference Material no. 146) were measured using each of the detector candidates in the same geometry. The net count rates recorded by each detector at 186 keV and 1,001 keV were plotted as a function of enrichment (atom percentage). Background measurements were made in unshielded and shielded configurations under both ambient and elevated conditions of 238U activity. The highly enriched uranium hold-up measurement campaign at the Portsmouth plant was performed on process equipment that had been cleaned out. Therefore, in most cases, the thickness of the uranium deposits was less than the “infinite thickness” for the 186 keV gamma rays to be completely self-attenuated. Because of this, in addition to measuring the 186 keV gamma, the 1,001 keV gamma ray from 234mPa—a daughter of 238U in secular

  16. Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from healthy individuals in the Nordic countries.

    Science.gov (United States)

    Larsen, Tine Lise; Nilsen, Valentina; Andersen, Dag Olav; Francis, George; Rustad, Pål; Mansoor, Mohammad Azam

    2008-12-01

    Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum. The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method. The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (pHPLC method.

  17. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

    International Nuclear Information System (INIS)

    Gupta, D.; Gota, H.; Hayashi, R.; Kiyashko, V.; Morehouse, M.; Primavera, S.; Bolte, N.; Marsili, P.; Roche, T.; Wessel, F.

    2010-01-01

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  18. In-situ gamma spectroscopic measurement of natural waters in Bulgaria

    International Nuclear Information System (INIS)

    Manushev, B.; Mandzhukov, I.; Tsankov, L.; Boshkova, T.; Gurev, V.; Mandzhukova, B.; Kozhukharov, I.; Grozev, G.

    1983-01-01

    In-situ gamma spectrometric measurements are carried out to record differences higher than the errors of measurement in the gamma-field spectra in various basins in Bulgaria - two high mountain lakes, dam and the Black sea. A standard scintillation gamma spectrometer, consisting of a scintillation detector ND-424 type, a channel analyzer NP-424 and a 128 channel Al-128 type analyzer, has been used. The sensitivity of the procedure used is sufficient to detect the transfer of nuclides by dissolution from rocks, forming the bottom and the water-collecting region of the water basin. The advancement of the experimental techniques defines the future use of the procedure. In-situ gamma spectrometric determination may be used in cases of continuous and automated control of the radiation purity of the cooling water in atomic power plants or the water basins located close to such plants and of radioactive contamination of the sea and ocean water

  19. Laser induced breakdown spectroscopy of the uranium including calcium. Time resolved measurement spectroscopic analysis (Contract research)

    International Nuclear Information System (INIS)

    Akaoka, Katsuaki; Maruyama, Youichiro; Oba, Masaki; Miyabe, Masabumi; Otobe, Haruyoshi; Wakaida, Ikuo

    2010-05-01

    For the remote analysis of low DF TRU (Decontamination Factor Transuranic) fuel, Laser Breakdown Spectroscopy (LIBS) was applied to uranium oxide including a small amount of calcium oxide. The characteristics, such as spectrum intensity and plasma excitation temperature, were measured using time-resolved spectroscopy. As a result, in order to obtain the stable intensity of calcium spectrum for the uranium spectrum, it was found out that the optimum observation delay time of spectrum is 4 microseconds or more after laser irradiation. (author)

  20. Millimeter wave spectroscopic measurements of stratospheric and mesospheric constituents over the Italian Alps: stratospheric ozone

    Directory of Open Access Journals (Sweden)

    V. Romaniello

    2007-06-01

    Full Text Available Measurements of rotational lines emitted by middle atmospheric trace gases have been carried out from the Alpine station of Testa Grigia (45.9°N, 7.7°E, elev. 3500 m by means of a Ground-Based Millimeter-wave Spectrometer (GBMS. Observations of species such as O3, HNO3, CO, N2O, HCN, and HDO took place during 4 winter periods, from February 2004 to March 2007, for a total of 116 days of measurements grouped in about 18 field campaigns. By studying the pressure-broadened shape of emission lines the vertical distribution of the observed constituents is retrieved within an altitude range of ?17-75 km, constrained by the 600 MHz pass band and the 65 kHz spectral resolution of the back-end spectrometer. This work discusses the behavior of stratospheric O3 during the entire period of operation at Testa Grigia. Mid-latitude O3 columnar content as estimated using GBMS measurements can vary by large amounts over a period of very few days, with the largest variations observed in December 2005, February 2006, and March 2006, confirming that the northern winter of 2005-2006 was characterized by a particularly intense planetary wave activity. The largest rapid variation from maximum to minimum O3 column values over Testa Grigia took place in December 2006 and reached a relative value of 72% with respect to the average column content for that period. During most GBMS observation times much of the variability is concentrated in the column below 20 km, with tropospheric weather systems and advection of tropical tropospheric air into the lower stratosphere over Testa Grigia having a large impact on the observed variations in column contents. Nonetheless, a wide variability is also found in middle stratospheric GBMS O3 measurements, as expected for mid-latitude ozone. We find that O3 mixing ratios at ?32 km are very well correlated with the solar illumination experienced by air masses over the previous ?15 days, showing that already at 32 km

  1. Correlating the vibrational spectra of structurally related molecules: A spectroscopic measure of similarity.

    Science.gov (United States)

    Tao, Yunwen; Zou, Wenli; Cremer, Dieter; Kraka, Elfi

    2018-03-05

    Using catastrophe theory and the concept of a mutation path, an algorithm is developed that leads to the direct correlation of the normal vibrational modes of two structurally related molecules. The mutation path is defined by weighted incremental changes in mass and geometry of the molecules in question, which are successively applied to mutate a molecule into a structurally related molecule and thus continuously converting their normal vibrational spectra from one into the other. Correlation diagrams are generated that accurately relate the normal vibrational modes to each other by utilizing mode-mode overlap criteria and resolving allowed and avoided crossings of vibrational eigenstates. The limitations of normal mode correlation, however, foster the correlation of local vibrational modes, which offer a novel vibrational measure of similarity. It will be shown how this will open new avenues for chemical studies. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Electron spectroscopic evidence of electron correlation in Ni-Pt alloys: comparison with specific heat measurement

    CERN Document Server

    Nahm, T U; Kim, J Y; Oh, S J

    2003-01-01

    We have performed photoemission spectroscopy of Ni-Pt alloys to understand the origin of the discrepancy between the experimental linear coefficient of specific heat gamma and that predicted by band theory. We found that the quasiparticle density of states at the Fermi level deduced from photoemission measurement is in agreement with the experimental value of gamma, if we include the electron correlation effect. It was also found that the Ni 2p core level satellite intensity increases as Ni content is reduced, indicating a strong electron correlation effect which can enhance the quasiparticle effective mass considerably. This supports our conclusion that electron correlation is the most probable reason of disagreement of gamma between experiment and band theory.

  3. Active spectroscopic measurements of the bulk deuterium properties in the DIII-D tokamak (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Grierson, B. A.; Pablant, N. A.; Solomon, W. M. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Burrell, K. H.; Groebner, R. J.; Kaplan, D. H.; Van Zeeland, M. A. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Chrystal, C. [University of California San Diego, La Jolla, California 92093 (United States); Heidbrink, W. W. [University of California Irvine, Irvine, California 92697 (United States); Munoz Burgos, J. M. [Oak Ridge Institute for Science Education, Oak Ridge, Tennessee 37831-0117 (United States)

    2012-10-15

    The neutral-beam induced D{sub {alpha}} emission spectrum contains a wealth of information such as deuterium ion temperature, toroidal rotation, density, beam emission intensity, beam neutral density, and local magnetic field strength magnitude Double-Vertical-Line B Double-Vertical-Line from the Stark-split beam emission spectrum, and fast-ion D{sub {alpha}} emission (FIDA) proportional to the beam-injected fast ion density. A comprehensive spectral fitting routine which accounts for all photoemission processes is employed for the spectral analysis. Interpretation of the measurements to determine physically relevant plasma parameters is assisted by the use of an optimized viewing geometry and forward modeling of the emission spectra using a Monte-Carlo 3D simulation code.

  4. Active spectroscopic measurements of the bulk deuterium properties in the DIII-D tokamak (invited).

    Science.gov (United States)

    Grierson, B A; Burrell, K H; Chrystal, C; Groebner, R J; Kaplan, D H; Heidbrink, W W; Muñoz Burgos, J M; Pablant, N A; Solomon, W M; Van Zeeland, M A

    2012-10-01

    The neutral-beam induced D(α) emission spectrum contains a wealth of information such as deuterium ion temperature, toroidal rotation, density, beam emission intensity, beam neutral density, and local magnetic field strength magnitude |B| from the Stark-split beam emission spectrum, and fast-ion D(α) emission (FIDA) proportional to the beam-injected fast ion density. A comprehensive spectral fitting routine which accounts for all photoemission processes is employed for the spectral analysis. Interpretation of the measurements to determine physically relevant plasma parameters is assisted by the use of an optimized viewing geometry and forward modeling of the emission spectra using a Monte-Carlo 3D simulation code.

  5. Doppler spectroscopic measurements of sheath ion velocities in radio-frequency plasmas

    International Nuclear Information System (INIS)

    Woodcock, B.K.; Busby, J.R.; Freegarde, T.G.; Hancock, G.

    1997-01-01

    We have measured the distributions of N 2 + ion velocity components parallel and perpendicular to the electrode in the sheath of a radio-frequency nitrogen reactive ion etching discharge, using pulsed laser-induced fluorescence. Parallel to the electrode, the ions have throughout a thermal distribution that is found to be consistent with the rotational temperature of 355 K. In the perpendicular direction, we see clearly the acceleration of the ions towards the electrode, and our results agree well with theoretical predictions although an unexpected peak of unaccelerated ions persists. We have also determined the absolute ion concentrations in the sheath, which we have calibrated by analyzing the decay in laser-induced fluorescence in the plasma bulk after discharge extinction. At 20 mTorr, the bulk concentration of 1.0x10 10 cm -3 falls to around 2x10 8 cm -3 at 2 mm from the electrode. copyright 1997 American Institute of Physics

  6. Spectroscopic techniques for measuring ion diode space-charge distributions and ion source properties

    Energy Technology Data Exchange (ETDEWEB)

    Filuk, A B; Bailey, J E; Adams, R G [Sandia Labs., Albuquerque, NM (United States); and others

    1997-12-31

    The authors are using time- and space-resolved visible spectroscopy to measure applied-B ion diode dynamics on the 20 TW Particle Beam Fusion Accelerator II. Doppler broadening of fast Li atoms, as viewed parallel to the anode, is used in a charge-exchange model to obtain the Li{sup +} ion divergence within 100 {mu}m of the anode surface. The characteristic Stark/Zeeman shifts in spectra of alkali neutrals or singly-ionized alkaline-earths are used to measure the strong electric (10{sup 9} V/m) an magnetic ({approx} 6 T) fields in the diode gap. Large Stark shifts within 0.5 mm of the anode indicate the LiF emits with a finite field threshold rather than with Child-Langmuir-type emission, and the small slope in the electric field indicates an unexpected build-up of electrons near the anode. In the diode gap, the authors aim to unfold fields to quantify the time-dependent ion and electron space-charge distributions that determine the ion beam properties. Observed electric field non-uniformities give local beam deflections that can be comparable to the total beam microdivergence. The authors are implementing active laser absorption and laser-induced fluorescence spectroscopy on low-density Na atoms injected into the diode gap prior to the power pulse. The small Doppler broadening in the Na spectra should allow simultaneous electric and magnetic field mapping with improved spatial resolution. (author). 4 figs., 13 refs.

  7. Titration and Spectroscopic Measurements of Poultry Litter pH Buffering Capacity.

    Science.gov (United States)

    Cassity-Duffey, Kate; Cabrera, Miguel; Mowrer, Jake; Kissel, David

    2015-07-01

    The pH value of poultry litter is affected by nitrification, mineralization, and the addition of acidifying chemicals, all acting on the poultry litter pH buffering capacity (pHBC). Increased understanding of poultry litter pHBC will aid in modeling NH volatilization from surface-applied poultry litter as well as estimating rates of alum applications. Our objectives were to (i) determine the pHBC of a wide range of poultry litters; (ii) assess the accuracy of near-infrared reflectance spectroscopy (NIRS) for determining poultry litter pHBC; and (iii) demonstrate the use of poultry litter pHBC to increase the accuracy of alum additions. Litter pHBC was determined by titration and calculated from linear and sigmoidal curves. For the 37 litters measured, linear pHBC ranged from 187 to 537 mmol (pH unit) kg dry litter. The linear and sigmoidal curves provided accurate predictions of pHBC, with most > 0.90. Results from NIRS analysis showed that the linear pHBC expressed on an "as is" water content basis had a NIRS coefficient of calibration (developed using a modified partial least squares procedure) of 0.90 for the 37 poultry litters measured. Using the litter pHBC, an empirical model was derived to determine the amount of alum needed to create a target pH. The model performed well in the range of pH 6.5 to 7.5 (RMSE = 0.07) but underpredicted the amount of alum needed to reach pH litter, which prevented its hydrolysis. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  8. Preliminary Marine Safety Risk Assessment, Brandon Road Lock and Dam Invasive Species Control Measures

    Science.gov (United States)

    2016-12-01

    Decision makers must include control-measure monitoring and emergency “interventions” to insure safety. The Coast Guard operational commanders...system” incorporates a travelling car on a rail above the barge-loading wharf to prevent loading personnel, cargo surveyors, or others from falling...to the Gulf of Mexico . As “Loopers”, they will have already transited the CSSC electric barriers. Preliminary Marine Safety Risk Assessment, BRLD

  9. Preliminary results of natural radioactivity measurements in the southern part of Ethiopia

    International Nuclear Information System (INIS)

    Wollel Tiruneh, Getachew; Wodaje Kebede, Worku

    2008-01-01

    The paper presents the first results of natural radioactivity measurements in the Southern part of Ethiopia (Bale Zone-Oromiya Regional State). The preliminary results indicate that radiation levels in the mining areas of Kallido Mountain are elevated compared with those in the town of Negele Borena (background area). Both external gamma radiation and alpha surface contamination levels are significantly elevated above local background levels

  10. Preliminary results of natural radioactivity measurements in the southern part of Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Wollel Tiruneh, Getachew [Ethiopian Radiation Protection Authority, PO Box 20486 code 1000, Addis-Ababa (Ethiopia)], E-mail: gwollel@yahoo.com; Wodaje Kebede, Worku [Ethiopian Radiation Protection Authority, PO Box 20486 code 1000, Addis-Ababa (Ethiopia)

    2008-11-15

    The paper presents the first results of natural radioactivity measurements in the Southern part of Ethiopia (Bale Zone-Oromiya Regional State). The preliminary results indicate that radiation levels in the mining areas of Kallido Mountain are elevated compared with those in the town of Negele Borena (background area). Both external gamma radiation and alpha surface contamination levels are significantly elevated above local background levels.

  11. Ionization Spectroscopic Measurement of nP Rydberg Levels of 87Rb Cold Atoms

    Science.gov (United States)

    Li, Yufan; Zaheeruddin, Syed; Zhao, Dongmei; Ma, Xinwen; Yang, Jie

    2018-05-01

    We created an ultracold plasma via the spontaneous ionization of cold dense Rydberg atoms of 87Rb in a magneto-optical trap (MOT), and measured the nS1/2 (n = 50-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 49-96) Rydberg levels by detecting the electrons in the ultracold plasma. By fitting the energy levels of Rydberg states, the first ionization potential of 33690.950(11) cm-1 and the quantum defects of S, P, and D orbitals were obtained. The absolute transition energies of nS1/2 (n = 66-80), nP1/2 (n = 16-23), nP3/2 (n = 16-98), and nD5/2 (n = 58-96) states of 87Rb, as well as the quantum defects for p1/2 and p3/2 series, are given for the first time.

  12. High-pressure measuring cell for Raman spectroscopic studies of natural gas

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2001-01-01

    A system for obtaining Raman spectra of gases at high pressure has been constructed. In order to ensure that a natural gas sample is totally representative, a high-pressure gas-measuring cell has been developed, built up by stainless steel fittings and a sapphire tube. The design and construction...... of this cell are described. A perfect pressure seal has been demonstrated up to 15.0 MPaA (MPa absolute). The cell has been successfully used to obtain Raman spectra of natural gas samples. Some of these spectra are presented and assigned. The most remarkable observation in the spectra is that it is possible...... to detect hydrogen sulfide at concentrations of 1-3 mg H2S/Nm(3). An attempt to make a quantitative analysis of natural gas by the so-called "ratio method" is presented. In addition to this, the relative normalized differential Raman scattering cross sections for ethane and i-butane molecules at 8.0 MPa...

  13. 31P MR spectroscopic measurement of intracellular pH in normal human hearts

    International Nuclear Information System (INIS)

    Kwon, Jae Hyun; Lee, Hui Joong; Jang, Yong Min

    2002-01-01

    To assess the usefulness of intracellular pH (pHi), calculated by determining the shift of a high-energy metabolite such as inorganic phosphate (Pi) of γ-ATP after performing MRS with ECG-gated two-dimensional 31 P CSI (chemical shift imaging), as a parameter for the overall state of the intracellular milieu. Proto decoupled 31 P CSI was performed on a 1.5-T scanner using a 1 H 31 P dual-tuned surface coil. Cardiac MRS data were obtained from eight normal volunteers aged 24-32 years with no history of heart disease. From the spectra obtained from several regions of the heart, peack position and peak area were estimated. The metabolic ratios of α-, β-, γ-ATP, PCr, Pi, phosphodiester and diphosphoglycerate were calculated, and pHi was estimated from the chemical shift of Pi and γ-ATP resonance. We then compared the data for the anterior myocardium with those previously published. The major phosphorous metabolites identified in these human hearts were as follows: PCr, at -0.1 to +0.1 ppm; three phosphate peaks from ATP, with a chemical shift centered at about -2.7 ppm (γ-ATP), -7.8 ppm (α-ATP), and -16.3 ppm (β-ATP); and phosphodiester (PDE) at 2-3 ppm, inorganic phosphate (Pi) at 4.5-5.4 ppm, and diphosphoglycerate (DPG) at 5.4-6.3 ppm. The PCr/β-ATP ratio was 2.20±0.17 and the PDE/β-ATP ratio, 1.04±0.09 pHi readings were 7.31±0.23 (calculated by the shift of Pi) and 6.81±0.20 (calculated by the shift of γ-ATP). Pi/PCR was 0.539, a ratio higher than that mentioned in previously published reports. The measurement of intracellular metabolism was affected by various kinds of factors. We believe, however, that pHi readings indicate the overall state of the cardiac intracellular milieu. An unexpected pHi readings, seen at MRS, may reflect errors in the MR procedure itself and, or in the analytical method

  14. {sup 31}P MR spectroscopic measurement of intracellular pH in normal human hearts

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Hyun; Lee, Hui Joong; Jang, Yong Min [Kyungpook National Univ., Taegu (Korea, Republic of)] [and others

    2002-05-01

    To assess the usefulness of intracellular pH (pHi), calculated by determining the shift of a high-energy metabolite such as inorganic phosphate (Pi) of {gamma}-ATP after performing MRS with ECG-gated two-dimensional {sup 31}P CSI (chemical shift imaging), as a parameter for the overall state of the intracellular milieu. Proto decoupled {sup 31}P CSI was performed on a 1.5-T scanner using a {sup 1}H{sup 31}P dual-tuned surface coil. Cardiac MRS data were obtained from eight normal volunteers aged 24-32 years with no history of heart disease. From the spectra obtained from several regions of the heart, peack position and peak area were estimated. The metabolic ratios of {alpha}-, {beta}-, {gamma}-ATP, PCr, Pi, phosphodiester and diphosphoglycerate were calculated, and pHi was estimated from the chemical shift of Pi and {gamma}-ATP resonance. We then compared the data for the anterior myocardium with those previously published. The major phosphorous metabolites identified in these human hearts were as follows: PCr, at -0.1 to +0.1 ppm; three phosphate peaks from ATP, with a chemical shift centered at about -2.7 ppm ({gamma}-ATP), -7.8 ppm ({alpha}-ATP), and -16.3 ppm ({beta}-ATP); and phosphodiester (PDE) at 2-3 ppm, inorganic phosphate (Pi) at 4.5-5.4 ppm, and diphosphoglycerate (DPG) at 5.4-6.3 ppm. The PCr/{beta}-ATP ratio was 2.20{+-}0.17 and the PDE/{beta}-ATP ratio, 1.04{+-}0.09 pHi readings were 7.31{+-}0.23 (calculated by the shift of Pi) and 6.81{+-}0.20 (calculated by the shift of {gamma}-ATP). Pi/PCR was 0.539, a ratio higher than that mentioned in previously published reports. The measurement of intracellular metabolism was affected by various kinds of factors. We believe, however, that pHi readings indicate the overall state of the cardiac intracellular milieu. An unexpected pHi readings, seen at MRS, may reflect errors in the MR procedure itself and, or in the analytical method.

  15. High-Resolution Infrared Spectroscopic Measurements of Comet 2PlEncke: Unusual Organic Composition and Low Rotational Temperatures

    Science.gov (United States)

    Radeva, Yana L.; Mumma, Michael J.; Villanueva, Geronimo L.; Bonev, Boncho P.; DiSanti, Michael A.; A'Hearn, Michael F.; Dello Russo, Neil

    2013-01-01

    We present high-resolution infrared spectroscopic measurements of the ecliptic comet 2P/Encke, observed on 4-6 Nov. 2003 during its close approach to the Earth, using the Near Infrared Echelle Spectrograph on the Keck II telescope. We present flux-calibrated spectra, production rates, and mixing ratios for H2O, CH3OH, HCN, H2CO, C2H2, C2H6, CH4 and CO. Comet 2P/Encke is a dynamical end-member among comets because of its short period of 3.3 years. Relative to "organics-normal" comets, we determined that 2PlEncke is depleted in HCN, H2CO, C2H2, C2H6, CH4 and CO, but it is enriched in CH3OH. We compared mixing ratios of these organic species measured on separate dates, and we see no evidence of macroscopic chemical heterogeneity in the nucleus of 2P/Encke, however, this conclusion is limited by sparse temporal sampling. The depleted abundances of most measured species suggest that 2P/Encke may have formed closer to the young Sun, before its insertion to the Kuiper belt, compared with "organics-normal" comets - as was previously suggested for other depleted comets (e.g. C/1999 S4 (LINEAR)). We measured very low rotational temperatures of 20 - 30 K for H2O, CH3OH and HCN in the near nucleus region of 2P/Encke, which correlate with one of the lowest cometary gas production rates (approx. 2.6 x 10(exp 27) molecules/s) measured thus far in the infrared. This suggests that we are seeing the effects of more efficient radiative cooling, insufficient collisional excitation, and/or inefficient heating by fast H-atoms (and icy grains) in the observed region of the coma. Its extremely short orbital period, very low gas production rate, and classification as an ecliptic comet, make 2PlEncke an important addition to our growing database, and contribute significantly to the establishment of a chemical taxonomy of comets.

  16. The Anaclitic-Introjective Depression Assessment: Development and preliminary validity of an observer-rated measure.

    Science.gov (United States)

    Rost, Felicitas; Luyten, Patrick; Fonagy, Peter

    2018-03-01

    The two-configurations model developed by Blatt and colleagues offers a comprehensive conceptual and empirical framework for understanding depression. This model suggests that depressed patients struggle, at different developmental levels, with issues related to dependency (anaclitic issues) or self-definition (introjective issues), or a combination of both. This paper reports three studies on the development and preliminary validation of the Anaclitic-Introjective Depression Assessment, an observer-rated assessment tool of impairments in relatedness and self-definition in clinical depression based on the item pool of the Shedler-Westen Assessment Procedure. Study 1 describes the development of the measure using expert consensus rating and Q-methodology. Studies 2 and 3 report the assessment of its psychometric properties, preliminary reliability, and validity in a sample of 128 patients diagnosed with treatment-resistant depression. Four naturally occurring clusters of depressed patients were identified using Q-factor analysis, which, overall, showed meaningful and theoretically expected relationships with anaclitic/introjective prototypes as formulated by experts, as well as with clinical, social, occupational, global, and relational functioning. Taken together, findings reported in this paper provide preliminary evidence for the reliability and validity of the Anaclitic-Introjective Depression Assessment, an observer-rated measure that allows the detection of important nuanced differentiations between and within anaclitic and introjective depression. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Combining parallel detection of proton echo planar spectroscopic imaging (PEPSI) measurements with a data-consistency constraint improves SNR.

    Science.gov (United States)

    Tsai, Shang-Yueh; Hsu, Yi-Cheng; Chu, Ying-Hua; Kuo, Wen-Jui; Lin, Fa-Hsuan

    2015-12-01

    One major challenge of MRSI is the poor signal-to-noise ratio (SNR), which can be improved by using a surface coil array. Here we propose to exploit the spatial sensitivity of different channels of a coil array to enforce the k-space data consistency (DC) in order to suppress noise and consequently to improve MRSI SNR. MRSI data were collected using a proton echo planar spectroscopic imaging (PEPSI) sequence at 3 T using a 32-channel coil array and were averaged with one, two and eight measurements (avg-1, avg-2 and avg-8). The DC constraint was applied using a regularization parameter λ of 1, 2, 3, 5 or 10. Metabolite concentrations were quantified using LCModel. Our results show that the suppression of noise by applying the DC constraint to PEPSI reconstruction yields up to 32% and 27% SNR gain for avg-1 and avg-2 data with λ = 5, respectively. According to the reported Cramer-Rao lower bounds, the improvement in metabolic fitting was significant (p < 0.01) when the DC constraint was applied with λ ≥ 2. Using the DC constraint with λ = 3 or 5 can minimize both root-mean-square errors and spatial variation for all subjects using the avg-8 data set as reference values. Our results suggest that MRSI reconstructed with a DC constraint can save around 70% of scanning time to obtain images and spectra with similar SNRs using λ = 5. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Sensitivity Measurement of Transmission Computer Tomography: thePreliminary Experimental Study

    International Nuclear Information System (INIS)

    Widodo, Chomsin-S; Sudjatmoko; Kusminarto; Agung-BS Utomo; Suparta, Gede B

    2000-01-01

    This paper reports result of preliminary experimental study onmeasurement method for sensitivity of a computed tomography (CT) scanner. ACT scanner has been build at the Department of Physics, FMIPA UGM and itsperformance based on its sensitivity was measured. The result showed that themeasurement method for sensitivity confirmed this method may be developedfurther as a measurement standard. Although the CT scanner developed has anumber of shortcoming, the analytical results from the sensitivitymeasurement suggest a number of reparations and improvements for the systemso that improved reconstructed CT images can be obtained. (author)

  19. The Galileo System of Measurement: Preliminary Evidence for Precision, Stability, and Equivalance to Traditional Measures

    Science.gov (United States)

    Gillham, James; Woelfel, Joseph

    1977-01-01

    Describes the Galileo system of measurement operations including reliability and validity data. Illustrations of some of the relations between Galileo measures and traditional procedures are provided. (MH)

  20. Preliminary indoor thoron measurements in high radiation background area of southeastern coastal Orissa (India)

    International Nuclear Information System (INIS)

    Ramola, R. C.; Prasad, G.; Gusain, G. S.; Rautela, B. S.; Choubey, V. M.; Vidya Sagar, D.; Tokonami, S.; Sorimachi, A.; Sahoo, S. K.; Janik, M.; Ishikawa, T.

    2010-01-01

    This paper presents the preliminary results of radon and thoron measurements in the houses of Chhatrapur area of southeastern coast of Orissa (India). This area is one of the high radiation background radiation areas in India, which consists of monazite sand as the source of thoron. Both active and passive methods were employed for the measurements. Radon and thoron concentrations were measured in the houses of Chhatrapur area using twin cup radon dosemeters, RAD7 and radon-thoron discriminative detector (Raduet). Thoron progeny concentration was also measured in the houses using deposition rate measurements. Radon and thoron concentrations in the houses of study area were found to vary from 8 to 47 Bq m -3 and the below detection level to 77 Bq m -3 , respectively. While thoron progeny concentration in these houses ranges between 0.17 and 4.24 Bq m -3 , preliminary investigation shows that the thoron concentration is higher than radon concentration in the houses of the study area. The thoron progeny concentration was found to be comparatively higher, which forms a base for further study in the area. The comparison between the results of various techniques is presented in this paper. (authors)

  1. Preliminary indoor thoron measurements in high radiation background area of southeastern coastal Orissa (India)

    Energy Technology Data Exchange (ETDEWEB)

    Ramola, R C; Prasad, G; Gusain, G S; Rautela, B S [Dept. of Physics, H.N.B. Garhwal Univ., Badshahi Thaul, Tehri Garhwal 249 199 (India); Choubey, V M [Wadia Inst. of Himalayan Geology, Dehradun 248 001 (India); Vidya Sagar, D [Health Physics Unit (EAD, BARC), IRE, OSCOM, Matikhalo, Dt. Ganjam, Orissa 761 045 (India); Tokonami, S; Sorimachi, A; Sahoo, S K; Janik, M; Ishikawa, T [National Inst. of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263 8555 (Japan)

    2010-07-01

    This paper presents the preliminary results of radon and thoron measurements in the houses of Chhatrapur area of southeastern coast of Orissa (India). This area is one of the high radiation background radiation areas in India, which consists of monazite sand as the source of thoron. Both active and passive methods were employed for the measurements. Radon and thoron concentrations were measured in the houses of Chhatrapur area using twin cup radon dosemeters, RAD7 and radon-thoron discriminative detector (Raduet). Thoron progeny concentration was also measured in the houses using deposition rate measurements. Radon and thoron concentrations in the houses of study area were found to vary from 8 to 47 Bq m{sup -3} and the below detection level to 77 Bq m{sup -3}, respectively. While thoron progeny concentration in these houses ranges between 0.17 and 4.24 Bq m{sup -3}, preliminary investigation shows that the thoron concentration is higher than radon concentration in the houses of the study area. The thoron progeny concentration was found to be comparatively higher, which forms a base for further study in the area. The comparison between the results of various techniques is presented in this paper. (authors)

  2. Optical constants of CH3NH3PbBr3 perovskite thin films measured by spectroscopic ellipsometry

    KAUST Repository

    Alias, Mohd Sharizal; Dursun, Ibrahim; Saidaminov, Makhsud I.; Diallo, Elhadj Marwane; Mishra, Pawan; Ng, Tien Khee; Bakr, Osman; Ooi, Boon S.

    2016-01-01

    function) of CH3NH3PbBr3 perovskite thin films using spectroscopic ellipsometry. Due to the existence of voids, the refractive index of the thin films is around 8% less than the single crystals counterpart. The energy bandgap is around 2.309 eV as obtained

  3. A combination of preliminary results on gauge boson couplings measured by the LEP Experiments

    CERN Document Server

    CERN. Geneva

    2004-01-01

    This note presents a combination of published and preliminary measurements of triple gauge boson couplings (TGCs) and quartic gauge boson couplings (QGCs) from the four LEP experiments. We give an updated combination of the charged TGCs, g1z, kg and lg in single and multi-parameter fits. Updated results from the QGCs from the ZZgg vertex, ac/Lambda^2 and a0/Lambda^2, are given as well. The combinations of neutral TGCs hiv anf fiv are also presented, including an updated fiv combination.

  4. A preliminary improved measurement of the B hadron energy distribution in Z{sup 0} decays

    Energy Technology Data Exchange (ETDEWEB)

    SLD Collaboration

    1998-06-01

    The authors have measured the B hadron energy distribution in Z{sup 0} decays using a new technique applied to a sample of inclusive B decays recorded in the SLD experiment at SLAC between 1996 and 1997. The upgraded CCD vertex detector is used to reconstruct B-decay vertices with high efficiency and purity, and to provide precise measurements of the kinematic quantities used in this technique. For each reconstructed B-decay vertex, the part of the B energy missing from the vertex is derived from the kinematic quantities. B vertices with low missing mass are selected to provide a very high purity sample and to obtain good energy resolution. The authors compare the scaled B hadron energy distribution with the predictions of several QCD and phenomenological models of heavy quark fragmentation. The average scaled energy < x{sub B} > is measured to be 0.719{+-}0.005 (stat.){+-}0.001 (unfolding) (preliminary).

  5. Ultrasonic preliminary measurements of oenological malolactic fermentation parameters in red wine

    Science.gov (United States)

    Novoa-Díaz, D. F.; Puig-Pujol, A.; García-Álvarez, J.; Chávez, J. A.; Turó, A.; Mínguez, S.; García-Hernández, M. J.; Bertran, E.; Salazar, J.

    2012-12-01

    In the winemaking process, the malolactic fermentation is an essential process in the production of high quality red wines which concerns the conversion of malate into lactate. In this work, the ultrasonic velocity through wine samples with different concentrations of malate and lactate was measured using the pulse echo technique with 1 MHz tone burst signals. The evolution of these concentrations during malolactic fermentation was taken into account in order to determine the ratio between concentrations of malate and lactate of the different samples. These preliminary results have revealed that the ultrasonic velocity increases during the conversion of malate to lactate. In addition, measurements have been conducted to quantify the influence of variations in turbidity and temperature on test samples. Therefore, these results show the possibility of using ultrasonic velocity measurements for on-line monitoring the malolactic fermentation of red wine and may help to improve and contribute to the development of the winemaking process.

  6. A preliminary investigation into the measurement of global thunderstorm incidence and electrosphere potential at Sanae, Antarctica

    International Nuclear Information System (INIS)

    Smart, C.A.

    1980-01-01

    One of the atmospheric parameters that may be affected by variations in the electrosphere potential is thunderstorm activity. The author made preliminary investigations into the simultaneous monitoring of global thunderstorm incidence and electrosphere potential. The author looked at the structure of the sun and the earth solar activity and solar emissions as well as the sun-weather relationships. Measurement were made by the author during 1978 at Sanae, Antarctica. The objective was to investigate the fluctuations of global thunderstorm activity and electrosphere potential and to establish some link between these and with solar activity. Potential gradient of the lower atmosphere was measured by means of a field mill and fluctuations taken to be representative of those of the electrosphere potential. Thunderstorm incidence was monitored by measurement of extra low frequency (ELF) electromagnetic noise radiated by lightning. A dipole or loop antenna was used for the recording of extra low frequency electromagnetic noise. A computer program was developed to facilitate the data analysis

  7. Preliminary measurements of the establishment of a quality control programme for the activimeter calibration reference system

    International Nuclear Information System (INIS)

    Martins, Elaine W.; Potiens, Maria da Penha A.

    2009-01-01

    The nuclear medicine techniques efficiency and safety depends on, beside other factors, a quality control programme, mainly regards to the nuclides activimeter utilization. The Calibration Laboratory of IPEN uses as a work standard, a tertiary standard system Capintec, calibrated at the Accredited Dosimetry Calibration Laboratory of the Medical radiation Research Center - University of Wisconsin. In this work, as preliminary measurements to establish a quality control programme for the activimeter calibration procedures, initially the repeatability and reproducibility (long term stability) tests were performed using a sealed check source of 133 Ba. Later on, to complete this quality control programme other check sources ( 137 Cs, 57 Co, 60 Co) will be used to perform the same tests. A series of 80 experiments of 10 measurements each has been carried out. The reference system showed a good behaviour to the repeatability test, considering the tolerance limits of 5%. The percent deviations of all tested sources in the activity measurements were lower 1% to 133 Ba. (author)

  8. Ultrasonic preliminary measurements of oenological malolactic fermentation parameters in red wine

    International Nuclear Information System (INIS)

    Novoa-Díaz, D F; García-Álvarez, J; Chávez, J A; Turó, A; García-Hernández, M J; Salazar, J; Puig-Pujol, A; Mínguez, S; Bertran, E

    2012-01-01

    In the winemaking process, the malolactic fermentation is an essential process in the production of high quality red wines which concerns the conversion of malate into lactate. In this work, the ultrasonic velocity through wine samples with different concentrations of malate and lactate was measured using the pulse echo technique with 1 MHz tone burst signals. The evolution of these concentrations during malolactic fermentation was taken into account in order to determine the ratio between concentrations of malate and lactate of the different samples. These preliminary results have revealed that the ultrasonic velocity increases during the conversion of malate to lactate. In addition, measurements have been conducted to quantify the influence of variations in turbidity and temperature on test samples. Therefore, these results show the possibility of using ultrasonic velocity measurements for on-line monitoring the malolactic fermentation of red wine and may help to improve and contribute to the development of the winemaking process.

  9. Vibrational spectroscopic characterisation of salmeterol xinafoate polymorphs and a preliminary investigation of their transformation using simultaneous in situ portable Raman spectroscopy and differential scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Hassan Refat H. [Chemical and Forensic Sciences/University Analytical Centre, School of Life Sciences, University of Bradford, Richmond Road, Bradford BD7 1DP (United Kingdom); Edwards, Howell G.M. [Chemical and Forensic Sciences/University Analytical Centre, School of Life Sciences, University of Bradford, Richmond Road, Bradford BD7 1DP (United Kingdom)], E-mail: H.G.M.Edwards@bradford.ac.uk; Hargreaves, Michael D.; Munshi, Tasnim; Scowen, Ian J.; Telford, Richard J. [Chemical and Forensic Sciences/University Analytical Centre, School of Life Sciences, University of Bradford, Richmond Road, Bradford BD7 1DP (United Kingdom)

    2008-07-14

    Knowledge and control of the polymorphic phases of chemical compounds are important aspects of drug development in the pharmaceutical industry. Salmeterol xinafoate, a long acting {beta}-adrenergic receptor agonist, exists in two polymorphic Forms, I and II. Raman and near infrared spectra were obtained of these polymorphs at selected wavelengths in the range of 488-1064 nm; significant differences in the Raman and near-infrared spectra were apparent and key spectral marker bands have been identified for the vibrational spectroscopic characterisation of the individual polymorphs which were also characterised with X ray diffractometry. The solid-state transition of salmeterol xinafoate polymorphs was studied using simultaneous in situ portable Raman spectroscopy and differential scanning calorimetry isothermally between transitions. This method assisted in the unambiguous characterisation of the two polymorphic forms by providing a simultaneous probe of both the thermal and vibrational data. The study demonstrates the value of a rapid in situ analysis of a drug polymorph which can be of potential value for at-line in-process control.

  10. Vibrational spectroscopic characterisation of salmeterol xinafoate polymorphs and a preliminary investigation of their transformation using simultaneous in situ portable Raman spectroscopy and differential scanning calorimetry

    International Nuclear Information System (INIS)

    Ali, Hassan Refat H.; Edwards, Howell G.M.; Hargreaves, Michael D.; Munshi, Tasnim; Scowen, Ian J.; Telford, Richard J.

    2008-01-01

    Knowledge and control of the polymorphic phases of chemical compounds are important aspects of drug development in the pharmaceutical industry. Salmeterol xinafoate, a long acting β-adrenergic receptor agonist, exists in two polymorphic Forms, I and II. Raman and near infrared spectra were obtained of these polymorphs at selected wavelengths in the range of 488-1064 nm; significant differences in the Raman and near-infrared spectra were apparent and key spectral marker bands have been identified for the vibrational spectroscopic characterisation of the individual polymorphs which were also characterised with X ray diffractometry. The solid-state transition of salmeterol xinafoate polymorphs was studied using simultaneous in situ portable Raman spectroscopy and differential scanning calorimetry isothermally between transitions. This method assisted in the unambiguous characterisation of the two polymorphic forms by providing a simultaneous probe of both the thermal and vibrational data. The study demonstrates the value of a rapid in situ analysis of a drug polymorph which can be of potential value for at-line in-process control

  11. Summary report on the Japan-US workshop on the assessment of spectroscopic data for temperature and density measurements

    International Nuclear Information System (INIS)

    Wiese, W.L.; Fujita, J.

    1988-03-01

    This workshop was held as a part of the US-Japan Cooperative Fusion Program 1986 at the Institute of Plasma Physics, Nagoya University, on March 18 - 20, 1987. Talks were carried out on the following plasma diagnostic subjects, giving special consideration to the situation of spectroscopic data and the needs, availability and adequacy of the data: x-ray spectroscopy, VUV and visible region spectroscopy, plasma edge spectroscopy, polarization spectroscopy, charge exchange spectroscopy, excitation rate data, and spectral radiometry and spectroscopic data tables. The program of the workshop and the abstracts of the talks are given in the first part of this summary report. On the last day of the workshop, small groups were formed, which deliberated on the situation of spectroscopic data in the various diagnostic areas, and especially focused on the further needs of the data. The summary of the findings and recommendation are given in the second part. The workshop was attended by five US and 25 Japanese scientists, and greatly benefitted from the active participation of three quests. (Kako, I.)

  12. Performance of a low-cost methane sensor for ambient concentration measurements in preliminary studies

    Directory of Open Access Journals (Sweden)

    W. Eugster

    2012-08-01

    Full Text Available Methane is the second most important greenhouse gas after CO2 and contributes to global warming. Its sources are not uniformly distributed across terrestrial and aquatic ecosystems, and most of the methane flux is expected to stem from hotspots which often occupy a very small fraction of the total landscape area. Continuous time-series measurements of CH4 concentrations can help identify and locate these methane hotspots. Newer, low-cost trace gas sensors such as the Figaro TGS 2600 can detect CH4 even at ambient concentrations. Hence, in this paper we tested this sensor under real-world conditions over Toolik Lake, Alaska, to determine its suitability for preliminary studies before placing more expensive and service-intensive equipment at a given locality. A reasonably good agreement with parallel measurements made using a Los Gatos Research FMA 100 methane analyzer was found after removal of the strong sensitivities for temperature and relative humidity. Correcting for this sensitivity increased the absolute accuracy required for in-depth studies, and the reproducibility between two TGS 2600 sensors run in parallel is very good. We conclude that the relative CH4 concentrations derived from such sensors are sufficient for preliminary investigations in the search of potential methane hotspots.

  13. Measuring Problematic Mobile Phone Use: Development and Preliminary Psychometric Properties of the PUMP Scale

    Directory of Open Access Journals (Sweden)

    Lisa J. Merlo

    2013-01-01

    Full Text Available This study aimed to develop and assess the psychometric properties of an English language measure of problematic mobile phone use. Participants were recruited from a university campus, health science center, and other public locations. The sample included 244 individuals (68.4% female aged 18–75. Results supported a unidimensional factor structure for the 20-item self-report Problematic Use of Mobile Phones (PUMP Scale. Internal consistency was excellent (α=0.94. Strong correlations (r=.76, P<.001 were found between the PUMP Scale and an existing scale of cellular phone dependency that was validated in Asia, as well as items assessing frequency and intensity of mobile phone use. Results provide preliminary support for the use of the PUMP Scale to measure problematic use of mobile phones.

  14. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  15. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  16. Spectroscopic data

    CERN Document Server

    Melzer, J

    1976-01-01

    During the preparation of this compilation, many people contributed; the compilers wish to thank all of them. In particular they appreciate the efforts of V. Gilbertson, the manuscript typist, and those of K. C. Bregand, J. A. Kiley, and W. H. McPherson, who gave editorial assistance. They would like to thank Dr. J. R. Schwartz for his cooperation and encouragement. In addition, they extend their grati­ tude to Dr. L. Wilson of the Air Force Weapons Laboratory, who gave the initial impetus to this project. v Contents I. I ntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . 11. Organization ofthe Spectroscopic Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Methods of Production and Experimental Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Band Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2...

  17. Proposal of AAA-battery-size one-shot ATR Fourier spectroscopic imager for on-site analysis: Simultaneous measurement of multi-components with high accuracy

    Science.gov (United States)

    Hosono, Satsuki; Qi, Wei; Sato, Shun; Suzuki, Yo; Fujiwara, Masaru; Hiramatsu, Hiroyuki; Suzuki, Satoru; Abeygunawardhana, P. K. W.; Wada, Kenji; Nishiyama, Akira; Ishimaru, Ichiro

    2015-03-01

    For simultaneous measurement of multi-components on-site like factories, the ultra-compact (diameter: 9[mm], length: 45[mm], weight: 200[g]) one-shot ATR (Attenuated Total Reflection) Fourier spectroscopic imager was proposed. Because the proposed one-shot Fourier spectroscopic imaging is based on spatial-phase-shift interferometer, interferograms could be obtained with simple optical configurations. We introduced the transmission-type relativeinclined phase-shifter, that was constructed with a cuboid prism and a wedge prism, onto the optical Fourier transform plane of infinity corrected optical systems. And also, small light-sources and cameras in the mid-infrared light region, whose size are several millimeter on a side, are essential components for the ultra-compact spectroscopic configuration. We selected the Graphite light source (light source area: 1.7×1.7[mm], maker: Hawkeye technologies) whose radiation factor was high. Fortunately, in these days we could apply the cost-effective 2-dimensional light receiving device for smartphone (e.g. product name: LEPTON, maker: FLIR, price: around 400USD). In the case of alcoholic drinks factory, conventionally workers measure glucose and ethanol concentrations by bringing liquid solution back to laboratories every day. The high portable spectroscopy will make it possible to measure multi-components simultaneously on manufacturing scene. But we found experimentally that absorption spectrum of glucose and water and ethanol were overlapped each other in near infrared light region. But for mid-infrared light region, we could distinguish specific absorption peaks of glucose (@10.5[μm]) and ethanol (@11.5[μm]) independently from water absorption. We obtained standard curve between absorption (@9.6[μm]) and ethanol concentration with high correlation coefficient 0.98 successfully by ATR imaging-type 2-dimensional Fourier spectroscopy (wavelength resolution: 0.057[μm]) with the graphite light source (maker: Hawkeye

  18. Spectroscopic factors measurement of the five first energy levels of lead 208 nucleus using the 208Pb(e,e'p207Tl* huge pulse transfer reaction

    International Nuclear Information System (INIS)

    Medaglia, R.

    1999-08-01

    In this work, the spectral functions and the spectroscopic factors of the first five energy levels of the lead 208 nucleus have been measured using the 208 Pb(e,e'p) 207 Tl * reaction. The aim is to characterize the effect of the nuclear environment on pulse and energy distributions of protons. In order to minimize the ejected proton-residual nucleus interactions in the final state, the measurement has been performed at 750 and 570 MeV/c pulse transfers, and thus for proton kinetic energies of 263 MeV and 161 MeV, contrarily to a previous measurement performed at 100 MeV. A kinematics with a transverse electromagnetic coupling, instead of a longitudinal one, has been used because of the important coupling dependence observed for medium nuclei. The experiment has been carried out at the NIKHEF electron accelerator and smoothing ring. The pulse distributions of the first five energy levels for a proton pulse range of 0 to 300 MeV/c have been extracted from the (e,e'p) cross sections. An integration of model-dependent distributions gives the spectroscopic factors which indicate the number of protons of each level. These data rae compared to models that include both the proton interactions in the final state and the coulomb distortions. The Pavie model reproduces well the observed distributions and the transfer dependence, while the Ohio model does not. The spectroscopic factors obtained with the Pavie model are the same for both transfers and are 20% higher as an average than the previous experiment performed at 450 MeV/c. However, they are 30% below the shell model. The uncertain estimation of the reaction mechanisms does not allow to consider this reduction as being due exclusively to nuclear structure effects. (J.S.)

  19. Spectroscopic measurement of H(1S) and H sub 2 (v double prime ,J double prime ) in an H sup minus ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Stutzin, G.C.

    1990-08-01

    Low pressure H{sub 2} discharges have been used for some time as sources of H{sup {minus}} ions. These discharges contain many different species of particles which interact with each other and with the walls of the discharge chamber. Models exist that predict the populations of the various species for given macroscopic discharge parameters. However, many of the cross sections and wall catalyzation coefficients are unknown or somewhat uncertain. Therefore, it is of interest to measure the populations of as many of these species as possible, in order to determine the validity of the models. These models predict that H{sup {minus}} is created predominantly by the two-step process of vibrational excitation of hydrogen molecules followed by dissociative attachment of slow electrons to these vibrationally-excited hydrogen molecules. Many different collisional processes must be included in the models to explain the dependence of the various populations upon macroscopic parameters. This work presents results of spectroscopic measurements of the density and translational temperature of hydrogen atoms and of specific rotationally- and vibrationally-excited states of electronic ground-state H{sub 2}, in a discharge optimized for H{sup {minus}} production, as well as conventional measurements of the various charged species within the plasma. The spectroscopic measurements are performed directly by narrowband, single-photon absorption in the vacuum ultraviolet.

  20. Spectroscopic measurement of H(1S) and H2(v double-prime,J double-prime) in an H- ion source plasma

    International Nuclear Information System (INIS)

    Stutzin, G.C.

    1990-08-01

    Low pressure H 2 discharges have been used for some time as sources of H - ions. These discharges contain many different species of particles which interact with each other and with the walls of the discharge chamber. Models exist that predict the populations of the various species for given macroscopic discharge parameters. However, many of the cross sections and wall catalyzation coefficients are unknown or somewhat uncertain. Therefore, it is of interest to measure the populations of as many of these species as possible, in order to determine the validity of the models. These models predict that H - is created predominantly by the two-step process of vibrational excitation of hydrogen molecules followed by dissociative attachment of slow electrons to these vibrationally-excited hydrogen molecules. Many different collisional processes must be included in the models to explain the dependence of the various populations upon macroscopic parameters. This work presents results of spectroscopic measurements of the density and translational temperature of hydrogen atoms and of specific rotationally- and vibrationally-excited states of electronic ground-state H 2 , in a discharge optimized for H - production, as well as conventional measurements of the various charged species within the plasma. The spectroscopic measurements are performed directly by narrowband, single-photon absorption in the vacuum ultraviolet

  1. Using VIIRS Day/Night Band to Measure Electricity Supply Reliability: Preliminary Results from Maharashtra, India

    Directory of Open Access Journals (Sweden)

    Michael L. Mann

    2016-08-01

    Full Text Available Unreliable electricity supplies are common in developing countries and impose large socio-economic costs, yet precise information on electricity reliability is typically unavailable. This paper presents preliminary results from a machine-learning approach for using satellite imagery of nighttime lights to develop estimates of electricity reliability for western India at a finer spatial scale. We use data from the Visible Infrared Imaging Radiometer Suite (VIIRS onboard the Suomi National Polar Partnership (SNPP satellite together with newly-available data from networked household voltage meters. Our results point to the possibilities of this approach as well as areas for refinement. With currently available training data, we find a limited ability to detect individual outages identified by household-level measurements of electricity voltage. This is likely due to the relatively small number of individual outages observed in our preliminary data. However, we find that the approach can estimate electricity reliability rates for individual locations fairly well, with the predicted versus actual regression yielding an R2 > 0.5. We also find that, despite the after midnight overpass time of the SNPP satellite, the reliability estimates derived are representative of daytime reliability.

  2. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field.

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-06-25

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge.

  3. A Preliminary Design of a Wire Mesh Sensor for Measurement of Void Fraction

    International Nuclear Information System (INIS)

    Hong, Seong Ho; Kim, Jong Hwan; Song, Jin Ho; Hong, Seok Boong

    2006-01-01

    Steam explosion phenomena are accompanied with a multi-dimensional and multi-phase fluid flow and heat transfer phenomena. Void fraction is one of the major parameters, which governs the premixing behavior of melt particles in water and the explosion behavior of the pre-mixed fuel. However, efforts for the development of a reliable measurement technique for void fraction are still underway, as it deals with an interaction between a melt at a very high temperature and water in a short time scale. Hundreds of conductivity type probes installed in a test section enabled monitoring of the evolution of a melt-water interaction zone in the ECO test. A technique using a dual energy X-ray system was developed to measure gas fraction, liquid fraction, and melt fraction simultaneously for a small-scale steam explosion experiment. A high-energy X-ray system for monitoring multi-phase fractions is now being developed at CEA. Recently a measurement of multi-phase fractions by using a wire mesh system has been introduced. It has an advantage that the speed of the measurement is fast and a direct measurement is possible. As a part of a feasibility study on a wire mesh technique for a steam explosion experiment, this paper discusses the design of the wire mesh and the results of the preliminary calibration tests

  4. Preliminary analysis of surface radiation measurements recorded at the Nansen ice sheet (Antarctica)

    International Nuclear Information System (INIS)

    Bonafe', U.; Dalpane, E.; Georgiadis, T.; Pitacco, A.

    1996-01-01

    An experiment on radiation and surface energy balance was conducted during the 9. Italian expedition in Antarctica at the Nancen ice sheet, a glacier situated close to the Italian base at Terra Nova Bay, to correlate surface balances to the formation and development of katabatic winds. Measurements were taken by radiometers covering the whole spectra of solar and terrestrial emissions and by fast sensors of atmospheric wind velocity and humidity for the application of the eddy correlation technique. A preliminary analysis of the radiometric data collected in order to quantify the major components of radiative energy balance during the Antarctic summer in clear sky conditions is reported and discussed. The findings show the very low available energy (mean about 1 W/m 2 ), in terms of net radiation, for the physical processes such as sensible- and latent-heat fluxes. Long-wave radiation balance was applied to estimate the reliability of the Swinbank's parametrization, relative to general conditions of the atmosphere

  5. Development of methods to measure hemoglobin adducts by gel electrophoresis - Preliminary results

    International Nuclear Information System (INIS)

    Sun, J.D.; McBride, S.M.

    1988-01-01

    Chemical adducts formed on blood hemoglobin may be a useful biomarker for assessing human exposures to these compounds. This paper reports preliminary results in the development of methods to measure such adducts that may be generally applicable for a wide variety of chemicals. Male F344/N rats were intraperitoneally injected with 14 C-BaP dissolved in corn oil. Twenty-four hours later, the rats were sacrificed. Blood samples were collected and globin was isolated. Globin protein was then cleaved into peptide fragments using cyanogen bromide and the fragments separated using 2-dimensional gel electrophoresis. The results showed that the adducted 14 C-globin fragments migrated to different areas of the gel than did unadducted fragments. Further research is being conducted to develop methods that will allow quantitation of separated adducted globin fragments from human blood samples without the use of a radiolabel. (author)

  6. Measurement of pressure ridges in SAR images of sea ice - Preliminary results on scattering theory

    Science.gov (United States)

    Vesecky, J. F.; Smith, M. P.; Daida, J. M.; Samadani, R.; Camiso, J. C.

    1992-01-01

    Sea ice ridges and keels (hummocks and bummocks) are important in sea ice research for both scientific and practical reasons. A long-term objective is to make quantitative measurements of sea ice ridges using synthetic aperture radar (SAR) images. The preliminary results of a scattering model for sea ice ridge are reported. The approach is through the ridge height variance spectrum Psi(K), where K is the spatial wavenumber, and the two-scale scattering model. The height spectrum model is constructed to mimic height statistics observed with an airborne optical laser. The spectrum model is used to drive a two-scale scattering model. Model results for ridges observed at C- and X-band yield normalized radar cross sections that are 10 to 15 dB larger than the observed cross sections of multiyear ice over the range of angles of incidence from 10 to 70 deg.

  7. Preliminary measurements of k{sub 0} values for W-186

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Lívia F.; Dias, Mauro S.; Koskinas, Marina F.; Yamazaki, Ione M.; Semmler, Renato, E-mail: lfbarros@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    There are various methods of neutron activation analysis, one of these is the k{sub 0} Method for quantitative reactor Neutron Activation Analysis (NAA). The k{sub 0}-NAA procedure is nowadays widely used in numerous laboratories performing NAA all over the world. Among these reactions, {sup 186}W(n, γ){sup 187}W can be considered important because it can be used for a W concentration measurements. The irradiations were performed at position 24A, near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP - Nuclear and Energy Research Institute), in Sao Paulo, Brazil. Two irradiations were carried out in sequence, using two sets of samples: the first with a cadmium cover around the samples and the second without, in a total of three data sets with and without Cd cover performed in 2014 and 2015. The activity measurements were carried out in an HPGe gamma-ray spectrometer. Standard sources of {sup 152}Eu, {sup 133}Ba, {sup 60}Co and {sup 137}Cs supplied by the IAEA were used in order to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The covariance matrix methodology was applied to all uncertainties involved. The preliminary values of k{sub 0} for {sup 186}W(n, γ){sup 187}W reaction for the gamma transition energy of 479.53 keV was 3.17 x 10{sup -2}(5), for 618.77 keV was 9.08 x 10{sup -3}(15) and for 685.77 keV was 3.88x10{sup -2}(6). These preliminary values for k{sub 0} have been compared with the literature. (author)

  8. Spectroscopic study

    International Nuclear Information System (INIS)

    Flores, M.; Rodriguez, R.; Arroyo, R.

    1999-01-01

    This work is focused about the spectroscopic properties of a polymer material which consists of Polyacrylic acid (Paa) doped at different concentrations of Europium ions (Eu 3+ ). They show that to stay chemically joined with the polymer by a study of Nuclear Magnetic Resonance (NMR) of 1 H, 13 C and Fourier Transform Infrared Spectroscopy (Ft-IR) they present changes in the intensity of signals, just as too when this material is irradiated at λ = 394 nm. In according with the results obtained experimentally in this type of materials it can say that is possible to unify chemically the polymer with this type of cations, as well as, varying the concentration of them, since that these are distributed homogeneously inside the matrix maintaining its optical properties. These materials can be obtained more quickly and easy in solid or liquid phase and they have the best conditions for to make a quantitative analysis. (Author)

  9. ARPANSA preliminary measurements of radiofrequency transmissions from a Mesh Radio Smart meter

    International Nuclear Information System (INIS)

    Wijayasinghe, Don; Karipidis, Ken

    2013-01-01

    Smart meters have been deployed in buildings initially in Victoria and increasingly across other areas of Australia. They utilise radiofrequency (RF) electromagnetic energy (EME) at levels very much below the levels permitted in the RF Standard. Despite the low levels of RF EME, there is some public concern about exposures from smart meters and whether the RF transmissions may cause a variety of health effects. ARPANSA has undertaken some preliminary RF measurements of an installed mesh network smart meter at the home of a staff member in a suburb of Melbourne. It must be emphasised that these measurements by ARPANSA cannot be considered representative of all smart meters. A typical RF pulse from the smart meter had an average intensity of 7 mW/m 2 measured at a distance of half a metre from the smart meter with the door to the meter box open. This is 0.00015% of the instantaneous exposure limit in the Australian RF standard for the general public. The measured level with the meter box door closed, or on the other side of the wall on which the meter was mounted was about 20 times lower. The RF transmissions that were measured were not continuous and occurred less than 0.08% of the time that the measurements took place. The RF electromagnetic energy transmitted in a single pulse from the smart meter is similar to that from a car remote unlocking fob and much less than a single GSM SMS transmission. The measurements do not provide any indication of why smart meter transmissions would provoke symptoms in people otherwise unaffected by other wireless technologies such as mobile phone handsets. Indeed the low levels and short transmission times make any effects highly unlikely.

  10. Speciation of water soluble iron in size segregated airborne particulate matter using LED based liquid waveguide with a novel dispersive absorption spectroscopic measurement technique

    International Nuclear Information System (INIS)

    Chan, K.L.; Jiang, S.Y.N.; Ning, Z.

    2016-01-01

    In this study, we present the development and evaluation of a dispersive absorption spectroscopic technique for trace level soluble ferrous detection. The technique makes use of the broadband absorption spectra of the ferrous-ferrozine complex with a novel spectral fitting algorithm to determine soluble ferrous concentrations in samples and achieves much improved measurement precision compared to conventional methods. The developed method was evaluated by both model simulations and experimental investigations. The results demonstrated the robustness of the method against the spectral fluctuation, wavelength drift and electronic noise, while achieving excellent linearity (R 2  > 0.999) and low detection limit (0.06 μg L −1 ) for soluble ferrous detection. The developed method was also used for the speciation of soluble iron in size segregated atmospheric aerosols. The measurement was carried out during Spring and Summer in typical urban environment in Hong Kong. The measured total iron concentrations are in good agreement compared to conventional Inductively Coupled Plasma – Optical Emission Spectroscopy (ICP-OES) measurements. Investigation on ambient particulate matter samples shows the size dependent characteristic of iron speciation in the atmosphere with a more active role of fine particles in transforming between ferrous and ferric. The method demonstrated in this study provides a cost and time effective approach for the speciation of iron in ambient aerosols. - Highlights: • Dispersive absorption spectroscopic technique for trace level ferrous detection. • The spectral fitting retrieval improved the measurement precision and stability. • Extremely low detection limit was achieved for aqueous ferrous measurement. • Iron in size segregated particulate matters shows seasonal characteristic. • More active role of iron was found in fine particles compared to coarse particles.

  11. Speciation of water soluble iron in size segregated airborne particulate matter using LED based liquid waveguide with a novel dispersive absorption spectroscopic measurement technique

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K.L. [Meteorological Institute, Ludwig Maximilian University of Munich, Munich (Germany); School of Energy and Environment, City University of Hong Kong (Hong Kong); Jiang, S.Y.N. [School of Energy and Environment, City University of Hong Kong (Hong Kong); Ning, Z., E-mail: zhining@cityu.edu.hk [School of Energy and Environment, City University of Hong Kong (Hong Kong); Guy Carpenter Climate Change Centre, City University of Hong Kong (Hong Kong)

    2016-03-31

    In this study, we present the development and evaluation of a dispersive absorption spectroscopic technique for trace level soluble ferrous detection. The technique makes use of the broadband absorption spectra of the ferrous-ferrozine complex with a novel spectral fitting algorithm to determine soluble ferrous concentrations in samples and achieves much improved measurement precision compared to conventional methods. The developed method was evaluated by both model simulations and experimental investigations. The results demonstrated the robustness of the method against the spectral fluctuation, wavelength drift and electronic noise, while achieving excellent linearity (R{sup 2} > 0.999) and low detection limit (0.06 μg L{sup −1}) for soluble ferrous detection. The developed method was also used for the speciation of soluble iron in size segregated atmospheric aerosols. The measurement was carried out during Spring and Summer in typical urban environment in Hong Kong. The measured total iron concentrations are in good agreement compared to conventional Inductively Coupled Plasma – Optical Emission Spectroscopy (ICP-OES) measurements. Investigation on ambient particulate matter samples shows the size dependent characteristic of iron speciation in the atmosphere with a more active role of fine particles in transforming between ferrous and ferric. The method demonstrated in this study provides a cost and time effective approach for the speciation of iron in ambient aerosols. - Highlights: • Dispersive absorption spectroscopic technique for trace level ferrous detection. • The spectral fitting retrieval improved the measurement precision and stability. • Extremely low detection limit was achieved for aqueous ferrous measurement. • Iron in size segregated particulate matters shows seasonal characteristic. • More active role of iron was found in fine particles compared to coarse particles.

  12. Preliminary study of an integral harmonic analysis magnetic field measurement system for long SSC magnets

    International Nuclear Information System (INIS)

    Green, M.I.

    1991-04-01

    We described the research and development required to design and build a prototype system capable of making integrated magnetic multipole measurements of warm and cryogenic 50 mm bore SSC dipole and quadrupole magnets utilizing a warm probe in a warm finger. Our experience and some preliminary studies indicate that it is highly unlikely that a 16 meter long probe can be fabricated that will have a twist below several milliradians at any temperature. Consequently we describe a segmented 16 meter long probe for which we intend to calibrate the phase of each segment to within 0.1 milliradians. The data for all segments will be acquired simultaneously, and integrated data will be generated from the vector sums of the individual segments. The calibration techniques and instrumentation required to implement this system are described. The duration of an integral measurement at one current is less than ten seconds, which is three orders of magnitude shorter than that required by the mole technique presently being used. The system is based on an extrapolation of the techniques used at LBL to measure cryogenic 1 meter models of SSC magnets with a cryogenic probe. 3 refs., 3 figs

  13. Spectroscopic factors measurements in the s,d and f,p shells below and above the Coulomb barrier by (3He,d) reactions

    International Nuclear Information System (INIS)

    Baghdadi, Ahmed.

    1974-01-01

    The overlap of t and d or 3 He and d wave functions may be measured by one neutron transfer in (d,t) or one proton transfer in ( 3 He,d). The measurement of the resulting normalization constant has been performed in subcoulombic conditions in the case of 58 Ni( 3 He,d) 59 Cu and 60 Ni( 3 He,d) 61 Cu leading to the first 3/2 - and 1/2 - states with a position sensitive detector in a Buechner spectrograph. The result: D 2 =2.7+-0.2 10 4 MeV 2 fm 3 is in agreement with the D 2 measurement for (t,d) reactions [3.1+-0.2 10 4 MeV 2 fm 3 ] and with the theoretical value proposed by L.J.B. Goldfarg and coworkers. This result was used for a determination of the spectroscopic factors of the 1.379MeV 3/2 - state, the 1.507MeV 1/2 - state and the 1.758MeV 3/2 - state in 57 Co. The subcoulombic approximation is also shown to be valid even in the case of (d,p) reactions, by the measurement of angular distributions and excitation curves of 60 Ni(d,p) reactions leading to the excited states at 4.760MeV (l=2) and 4.907MeV (l=0). In the second part, some spectroscopic factors in the s-d shell were measured by ( 3 He,d) reactions at MP Tandem energies. In the case of 27 Al( 3 He,d) 28 Si (states at 4.62, 6.88, 6.89, 9.32 and 0.38MeV) the normalization constant D 0 2 (deduced from the subcoulombic D 2 value) together with the first order finite range approximation leads to spectroscopic factors in good agreement with Wildenthal theoretical results. For 28 Si( 3 He,d) 29 p however, the values are too high compared to 29 Si. The conclusion is that it is better to use the DWBA treatment at subcoulombic energies everytime the experimental conditions may be fulfilled [fr

  14. Development of laser atomic spectroscopic technology

    International Nuclear Information System (INIS)

    Lee, Jong Min; Ohr, Young Gie; Cha, Hyung Ki

    1990-06-01

    Some preliminary results on the resonant ionization spectroscopy for Na and Pb atoms are presents both in theory and in experiment. A single color multiphoton ionization process is theoretically analysed in detail, for the resonant and non-resonant cases, and several parameters determining the overall ionization rate are summarized. In particular, the AC stark shift, the line width and the non-linear coefficient of ionization rate are recalculated using the perturbation theory in resolvent approach. On the other hand, the fundamental equipments for spectroscopic experiments have been designed and manufactured, which include a Nd:YAG laser, a GIM-type dye laser, a vacuum system ionization cells, a heat pipe oven, and an ion current measuring system. The characteristics of the above equipments have also been examined. Using the spectroscopic data available, several ionization schemes are considered and the relative merits for ionization have been discussed. Moreover, the effects due to the buffer gas pressure, laser intensity, vapor density and electrode voltage have been investigated in detail. The experiments will be extended to multi-color processes with several resonances, and the ultimate goal is to develop a ultrasensitive analytical method for pollutive heavy metal atoms using the resonant ionization spectroscopy. (author)

  15. SYSTEMATIC UNCERTAINTIES IN THE SPECTROSCOPIC MEASUREMENTS OF NEUTRON STAR MASSES AND RADII FROM THERMONUCLEAR X-RAY BURSTS. III. ABSOLUTE FLUX CALIBRATION

    Energy Technology Data Exchange (ETDEWEB)

    Güver, Tolga [Istanbul University, Science Faculty, Department of Astronomy and Space Sciences, Beyazıt, 34119, Istanbul (Turkey); Özel, Feryal; Psaltis, Dimitrios [Department of Astronomy, University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Marshall, Herman [Center for Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Guainazzi, Matteo [European Space Astronomy Centre of ESA, P.O. Box 78, Villanueva de la Cañada, E-28691 Madrid (Spain); Díaz-Trigo, Maria [ESO, Karl-Schwarzschild-Strasse 2, D-85748 Garching bei München (Germany)

    2016-09-20

    Many techniques for measuring neutron star radii rely on absolute flux measurements in the X-rays. As a result, one of the fundamental uncertainties in these spectroscopic measurements arises from the absolute flux calibrations of the detectors being used. Using the stable X-ray burster, GS 1826–238, and its simultaneous observations by Chandra HETG/ACIS-S and RXTE /PCA as well as by XMM-Newton EPIC-pn and RXTE /PCA, we quantify the degree of uncertainty in the flux calibration by assessing the differences between the measured fluxes during bursts. We find that the RXTE /PCA and the Chandra gratings measurements agree with each other within their formal uncertainties, increasing our confidence in these flux measurements. In contrast, XMM-Newton EPIC-pn measures 14.0 ± 0.3% less flux than the RXTE /PCA. This is consistent with the previously reported discrepancy with the flux measurements of EPIC-pn, compared with EPIC MOS1, MOS2, and ACIS-S detectors. We also show that any intrinsic time-dependent systematic uncertainty that may exist in the calibration of the satellites has already been implicity taken into account in the neutron star radius measurements.

  16. Enhancing forensic science with spectroscopic imaging

    Science.gov (United States)

    Ricci, Camilla; Kazarian, Sergei G.

    2006-09-01

    This presentation outlines the research we are developing in the area of Fourier Transform Infrared (FTIR) spectroscopic imaging with the focus on materials of forensic interest. FTIR spectroscopic imaging has recently emerged as a powerful tool for characterisation of heterogeneous materials. FTIR imaging relies on the ability of the military-developed infrared array detector to simultaneously measure spectra from thousands of different locations in a sample. Recently developed application of FTIR imaging using an ATR (Attenuated Total Reflection) mode has demonstrated the ability of this method to achieve spatial resolution beyond the diffraction limit of infrared light in air. Chemical visualisation with enhanced spatial resolution in micro-ATR mode broadens the range of materials studied with FTIR imaging with applications to pharmaceutical formulations or biological samples. Macro-ATR imaging has also been developed for chemical imaging analysis of large surface area samples and was applied to analyse the surface of human skin (e.g. finger), counterfeit tablets, textile materials (clothing), etc. This approach demonstrated the ability of this imaging method to detect trace materials attached to the surface of the skin. This may also prove as a valuable tool in detection of traces of explosives left or trapped on the surfaces of different materials. This FTIR imaging method is substantially superior to many of the other imaging methods due to inherent chemical specificity of infrared spectroscopy and fast acquisition times of this technique. Our preliminary data demonstrated that this methodology will provide the means to non-destructive detection method that could relate evidence to its source. This will be important in a wider crime prevention programme. In summary, intrinsic chemical specificity and enhanced visualising capability of FTIR spectroscopic imaging open a window of opportunities for counter-terrorism and crime-fighting, with applications ranging

  17. Preliminary indoor radon and gamma measurements in kindergartens and schools in Bucharest

    International Nuclear Information System (INIS)

    Dumitrescu, A.; Milu, C.; Gheorghe, R.; Vaupotic, J.; Stegnar, P.

    2001-01-01

    A pilot study on indoor radon and gamma dose rates in schools and kindergartens (totalling one hundred buildings) in the Bucharest metropolitan area was performed jointly by the Institute of Public Health, Bucharest, Romania, and the J. Stefan Institute, Ljubljana, Slovenia. Because the geological structure of subsoil over the whole Bucharest area is uniform (a loess platform), the criteria for selecting a kindergarten or a school to be monitored were the age of the building and the building materials. Indoor radon concentrations were measured by a single one-month exposure of radon monitoring device based on etched track detectors in December 2000. Data show a lognormal distribution within the concentration range of 43/477 Bq/m 3 . An arithmetic mean of 146 Bq/m 3 and a geometric mean of 128 Bq/m 3 were obtained. Concomitant with indoor radon levels gamma dose rates were also measured, using thermoluminescent dosimeters. Values ranged from 54 to 100 μSv mo -1 , with a mean value of 74 μSv mo -1 . Having only a single average indoor radon concentration for a winter month, it is not possible to comment on our results, applying the ICRP Publication 65 methodology for indoor radon action level for the general public. Nevertheless, they give a preliminary picture of indoor radon and gamma dose rate levels in schools and kindergartens in Bucharest, and constitute a solid basis on which to design and perform a nation-wide radon survey programme.(author)

  18. Preliminary validation of a questionnaire to measure basic psychological needs in Physical Education

    Directory of Open Access Journals (Sweden)

    A. Pires

    2010-01-01

    Full Text Available The self-determination theory is a psychological approach to motivation that focuses on causes and consequences of human behavior regulation. According several authors, this theoretical framework could provide important information about the student’s motivational process to physical education class, however, in Portugal does not exists any instrument to measure the basic psychological needs in this domain. So, the main propose of this study is the preliminary adaptation to physical education contexts of Basic Psychological Needs Exercise Scale (Portuguese version: BPNESp, and determine their initial psychometrics properties through an exploratory factor analysis. This propose was accomplished with a sample of 150 students (n=150 from de 2nd and 3rd CEB, aged from 11 to 16 years (M = 13.39, SD = 1.44 with different levels of sports practice. Results revealed a factorial structure just like the original model (12 items grouped in 3 factors, with 4 items hitch factor and presents acceptable values of validity and reliability. Those findings allow us to conclude, that questionnaire can be used in future investigations to measure the basic psychological needs in physical education.

  19. 1995 Integrated Monitoring Study: Fog measurements in the Northern San Joaquin Valley - preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Collett, J. Jr.; Bator, A.; Sherman, D.E. [Colorado State Univ., Fort Collins, CO (United States)] [and others

    1996-12-31

    Vertical gradients in fog chemistry and physics were measured from a 430 m television broadcast tower in the northern San Joaquin Valley near Walnut Grove, California. Fog was collected on the ground and at two elevations on the tower using Caltech Active Strand Cloudwater Collectors Version 2 (CASCC2). Work was conducted as part of the 1995 Integrated Monitoring Study (IMS95). Results will be used to evaluate the need to make measurements aloft in future regional studies of fog processing of atmospheric particles and for testing whether vertically resolved fog models provide realistic simulations of fog physics and chemistry above the ground. Two fog/low cloud events were sampled during the tower study. Preliminary results show concentrations of major species in the fogwater typically decreasing with altitude, while liquid water contents increase. Fogwater loadings of major species, the total amount of a species in the aqueous phase per unit air volume, were observed to increase with altitude. Major species concentrations were typically quite stable at a given elevation, while significant decreases were observed over time in liquid water content. Fogwater concentrations of soluble hydroperoxides were highest near the surface and increased with time after sunrise and were observed to coexist in the high pH fog with S(IV). Time lapse video footage of the top of the fog/cloud layer revealed a very dynamic interface, suggesting entrainment of material from the clear air into the fog/cloud may be significant. 12 refs., 7 figs.

  20. Preliminary measurements on the new TOF system installed at the AMS beamline of INFN-LABEC

    Energy Technology Data Exchange (ETDEWEB)

    Palla, L., E-mail: palla@fi.infn.it [Dipartimento di Fisica, Università di Pisa, e INFN Sezione di Pisa (Italy); Castelli, L. [INFN Sezione di Firenze (Italy); Czelusniak, C. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Fedi, M.E. [INFN Sezione di Firenze (Italy); Giuntini, L. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Liccioli, L. [INFN Sezione di Firenze (Italy); Dipartimento di Chimica Ugo Schiff, Università di Firenze (Italy); Mandò, P.A. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Martini, M. [Dipartimento di Scienza dei Materiali, Università di Milano Bicocca, e INFN Sezione di Milano Bicocca, Milano (Italy); Mazzinghi, A. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Ruberto, C. [INFN Sezione di Firenze (Italy); Dipartimento di Chimica Ugo Schiff, Università di Firenze (Italy); Schiavulli, L. [Dipartimento di Fisica, Università di Bari, e INFN Sezione di Bari (Italy); Sibilia, E. [Dipartimento di Scienza dei Materiali, Università di Milano Bicocca, e INFN Sezione di Milano Bicocca, Milano (Italy); Taccetti, F. [INFN Sezione di Firenze (Italy)

    2015-10-15

    A high resolution time of flight (TOF) system has been developed at LABEC, the 3 MV Tandem accelerator laboratory in Florence, in order to improve the sensitivity of AMS measurements on carbon samples with ultra-low concentration and also to measure other isotopes, such as {sup 129}I. The system can be employed to detect and identify residual interfering particles originated from the break-up of molecular isobars. The set-up has been specifically designed for low energy heavy ions: it consists of two identical time pick-off stations, each made up of a thin conductive foil and a Micro-Channel Plate (MCP) multiplier. The beamline is also equipped with a silicon detector, installed downstream the stop TOF station. In this paper the design of the new system and the implemented readout electronics are presented. The tests performed on the single time pick-off station are reported: they show that the maximum contribution to the timing resolution given by both the intrinsic MCP resolution and the electronics is ⩽500 ps (FWHM). For these tests, single particle pulsed beams of 2–5 MeV protons and 10 MeV {sup 12}C{sup 3+} ions, to simulate typical AMS conditions, were used. The preliminary TOF and TOF-E (TOF-energy) measurements performed with carbon beams after the installation of the new system on the AMS beam line are also discussed. These measurements were performed using the foil–MCP as the start stage and a silicon detector as the stop stage. The spectra acquired with carbon ions suggest the presence of a small residual background from neighboring masses reaching the end of the beamline with the same energy as the rare isotope.

  1. Preliminary measurements on the new TOF system installed at the AMS beamline of INFN-LABEC

    International Nuclear Information System (INIS)

    Palla, L.; Castelli, L.; Czelusniak, C.; Fedi, M.E.; Giuntini, L.; Liccioli, L.; Mandò, P.A.; Martini, M.; Mazzinghi, A.; Ruberto, C.; Schiavulli, L.; Sibilia, E.; Taccetti, F.

    2015-01-01

    A high resolution time of flight (TOF) system has been developed at LABEC, the 3 MV Tandem accelerator laboratory in Florence, in order to improve the sensitivity of AMS measurements on carbon samples with ultra-low concentration and also to measure other isotopes, such as "1"2"9I. The system can be employed to detect and identify residual interfering particles originated from the break-up of molecular isobars. The set-up has been specifically designed for low energy heavy ions: it consists of two identical time pick-off stations, each made up of a thin conductive foil and a Micro-Channel Plate (MCP) multiplier. The beamline is also equipped with a silicon detector, installed downstream the stop TOF station. In this paper the design of the new system and the implemented readout electronics are presented. The tests performed on the single time pick-off station are reported: they show that the maximum contribution to the timing resolution given by both the intrinsic MCP resolution and the electronics is ⩽500 ps (FWHM). For these tests, single particle pulsed beams of 2–5 MeV protons and 10 MeV "1"2C"3"+ ions, to simulate typical AMS conditions, were used. The preliminary TOF and TOF-E (TOF-energy) measurements performed with carbon beams after the installation of the new system on the AMS beam line are also discussed. These measurements were performed using the foil–MCP as the start stage and a silicon detector as the stop stage. The spectra acquired with carbon ions suggest the presence of a small residual background from neighboring masses reaching the end of the beamline with the same energy as the rare isotope.

  2. Raman Spectroscopic Studies of Methane Gas Hydrates

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.

    2009-01-01

    A brief review of the Raman spectroscopic studies of methane gas hydrates is given, supported by some new measurements done in our laboratory.......A brief review of the Raman spectroscopic studies of methane gas hydrates is given, supported by some new measurements done in our laboratory....

  3. Patient empowerment in long-term conditions: development and preliminary testing of a new measure

    Science.gov (United States)

    2013-01-01

    Background Patient empowerment is viewed by policy makers and health care practitioners as a mechanism to help patients with long-term conditions better manage their health and achieve better outcomes. However, assessing the role of empowerment is dependent on effective measures of empowerment. Although many measures of empowerment exist, no measure has been developed specifically for patients with long-term conditions in the primary care setting. This study presents preliminary data on the development and validation of such a measure. Methods We conducted two empirical studies. Study one was an interview study to understand empowerment from the perspective of patients living with long-term conditions. Qualitative analysis identified dimensions of empowerment, and the qualitative data were used to generate items relating to these dimensions. Study two was a cross-sectional postal study involving patients with different types of long-term conditions recruited from general practices. The survey was conducted to test and validate our new measure of empowerment. Factor analysis and regression were performed to test scale structure, internal consistency and construct validity. Results Sixteen predominately elderly patients with different types of long-term conditions described empowerment in terms of 5 dimensions (identity, knowledge and understanding, personal control, personal decision-making, and enabling other patients). One hundred and ninety seven survey responses were received from mainly older white females, with relatively low levels of formal education, with the majority retired from paid work. Almost half of the sample reported cardiovascular, joint or diabetes long-term conditions. Factor analysis identified a three factor solution (positive attitude and sense of control, knowledge and confidence in decision making and enabling others), although the structure lacked clarity. A total empowerment score across all items showed acceptable levels of internal

  4. Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

    International Nuclear Information System (INIS)

    Hackstein, N.; Puille, M.F.; Bak, Benjamin H.; Scharwat, Oliver; Rau, W.S.

    2001-01-01

    Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r=0.78 with Cl (CT) [ml/min]=22.2+1.03 * Cl (serum), n=24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r=0.89 with rkf(CT)[%]=18.6+0.58 * rkf(scintigraphy), n=29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy

  5. A Preliminary Study on Time Projection Chamber Simulation for Fission Cross Section Measurements with Geant4

    International Nuclear Information System (INIS)

    Kim, Jong Woon; Lee, Youngouk; Kim, Jae Cheon

    2014-01-01

    We present the details of the TPC simulation with Geant4 and show the results. TPC can provide more information than a fission chamber in that it is possible to distinguish different particle types. Simulations are conducted for uranium and plutonium targets with 20MeV neutrons. The simulation results are compared with the reference and show reasonable results. This is the first phase of study for realizing a TPC in the NFS at RAON, and we have more work to do, such as applying an electric field, signal processing in the simulation, and manufacturing of a TPC. The standard in fission cross section measurement is a fission chamber. It is basically just two parallel plates separated by a few centimeters of gas. A power supply connected to the plates sets up a moderate electric field. The target is deposited onto one of the plates. When fission occurs, the fragments ionize the gas, and the electric field causes the produced electrons to drift to the opposite plate, which records the total energy deposited in the chamber. A Time Projection Chamber (TPC) is a gas ionization detector similar to a fission chamber. However, it can measure the charged particle trajectories in the active volume in three dimensions by adding several readouts on the pad plane (fission chamber has only one readout one a pad plane). The specific ionization for each particle track enables the TPC to distinguish different particle types. A TPC will be used for fission cross section measurements in the Neutron Science Facility (NSF) at RAON. As a preliminary study, we present details of TPC simulation with Geant4 and discuss the results

  6. Preliminary minimum detectable limit measurements in 208-L drums for selected actinide isotopes in mock-waste matrices

    International Nuclear Information System (INIS)

    Camp, D.C.; Wang, Tzu-Fang; Martz, H.E.

    1992-01-01

    Preliminary minimum detectable levels (MDLS) of selected actinide isotopes have been determined in full-scale, 55-gallon drums filled with a range of mock-waste materials from combustibles (0.14 g/CM 3 ) to sand (1.7 g/CM 3 ). Measurements were recorded from 100 to 10,000 seconds with selected actinide sources located in these drums at an edge position, on the center axis of a drum and midway between these two positions. Measurements were also made with a 166 Ho source to evaluate the attenuation of these mock-matrix materials as a function of energy. By knowing where the source activity is located within a drum, our preliminary results show that a simply collimated 90% HPGE detector can differentiate between TRU (>100 nCi/g) and LLW amounts of 239 Pu in only 100s of measurement time and with sufficient accuracy in both low and medium density, low Z materials. Other actinides measured so far include 235 U, 241 Am, and 244 Cm. These measurements begin to establish the probable MDLs achievable in the nondestructive assays of real waste drums when using active and passive CT. How future measurements may differ from these preliminary measurements is also discussed

  7. Mapping the nomological network of employee self-determined safety motivation: A preliminary measure in China.

    Science.gov (United States)

    Jiang, Li; Tetrick, Lois E

    2016-09-01

    The present study introduced a preliminary measure of employee safety motivation based on the definition of self-determination theory from Fleming (2012) research and validated the structure of self-determined safety motivation (SDSM) by surveying 375 employees in a Chinese high-risk organization. First, confirmatory factor analysis (CFA) was used to examine the factor structure of SDSM, and indices of five-factor model CFA met the requirements. Second, a nomological network was examined to provide evidence of the construct validity of SDSM. Beyond construct validity, the analysis also produced some interesting results concerning the relationship between leadership antecedents and safety motivation, and between safety motivation and safety behavior. Autonomous motivation was positively related to transformational leadership, negatively related to abusive supervision, and positively related to safety behavior. Controlled motivation with the exception of introjected regulation was negatively related to transformational leadership, positively related to abusive supervision, and negatively related to safety behavior. The unique role of introjected regulation and future research based on self-determination theory were discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R., E-mail: lfbarros@ipen.b, E-mail: brigitte@ipen.b, E-mail: raquino@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of {sup 226}Ra, {sup 232}Th and {sup 40}K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the {sup 238}U and {sup 232}Th series. The {sup 226}Ra concentration was determined from the weighted average concentrations of {sup 214}Pb and {sup 214}Bi. The {sup 232}Th concentration was determined from the weighted average concentrations of {sup 228}Ac, {sup 212}Pb and {sup 212}Bi and the {sup 40}K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg{sup -1} to {sup 222} Bq.kg{sup -1} for {sup 226}Ra and from 14 Bq.kg{sup -1} to 1074 Bq.kg{sup -'}1 for {sup 232}Th, both with the highest values for Camburi South and Central. For {sup 40}K, the activity concentrations ranged from 14 Bq.kg{sup -1} to 179 Bq.kg{sup -1} and the highest values were obtained for Camburi South. (author)

  9. Father involvement in Mexican-origin families: Preliminary development of a culturally informed measure.

    Science.gov (United States)

    Roubinov, Danielle S; Luecken, Linda J; Gonzales, Nancy A; Crnic, Keith A

    2016-04-01

    An increasing body of research has documented the significant influence of father involvement on children's development and overall well-being. However, extant research has predominately focused on middle-class Caucasian samples with little examination of fathering in ethnic minority and low-income families, particularly during the infancy period. The present study evaluated measures of early father involvement (paternal engagement, accessibility, and responsibility) that were adapted to capture important cultural values relevant to the paternal role in Mexican-origin families. A sample of 180 Mexican-origin mothers (M age = 28.3) and 83 Mexican-origin fathers (M age = 31.5) were interviewed during the perinatal period. Descriptive analyses indicated that Mexican-origin fathers are involved in meaningful levels of direct interaction with their infant. A 2-factor model of paternal responsibility was supported by factor analyses, consisting of a behavioral responsibility factor aligned with previous literature and culturally derived positive machismo factor. Qualities of the romantic relationship, cultural orientation, and maternal employment status were related to indices of father involvement. These preliminary results contribute to understanding of the transition to fatherhood among low-income Mexican-origin men and bring attention to the demographic, social, and cultural contexts in which varying levels of father involvement may emerge. (c) 2016 APA, all rights reserved).

  10. Father involvement in Mexican origin families: Preliminary development of culturally-informed measure

    Science.gov (United States)

    Roubinov, Danielle S.; Luecken, Linda J.; Gonzales, Nancy A.; Crnic, Keith A.

    2015-01-01

    Objectives An increasing body of research has documented the significant influence of father involvement on children’s development and overall well-being. However, extant research has predominately focused on middle-class Caucasian samples with little examination of fathering in ethnic minority and low-income families, particularly during the infancy period. The present study evaluated measures of early father involvement (paternal engagement, accessibility, and responsibility) that were adapted to capture important cultural values relevant to the paternal role in Mexican origin families. Methods A sample of 180 Mexican origin mothers (M age = 28.3) and 83 Mexican origin fathers (M age = 31.5) were interviewed during the perinatal period. Results Descriptive analyses indicated that Mexican origin fathers are involved in meaningful levels of direct interaction with their infant. A two-factor model of paternal responsibility was supported by factor analyses, consisting of a behavioral responsibility factor aligned with previous literature and culturally-derived positive machismo factor. Qualities of the romantic relationship, cultural orientation, and maternal employment status were related to indices of father involvement. Conclusions These preliminary results contribute to understanding of the transition to fatherhood among low-income Mexican origin men and bring attention to the demographic, social, and cultural contexts in which varying levels of father involvement may emerge. PMID:26237543

  11. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    International Nuclear Information System (INIS)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R.

    2011-01-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of 226 Ra, 232 Th and 40 K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the 238 U and 232 Th series. The 226 Ra concentration was determined from the weighted average concentrations of 214 Pb and 214 Bi. The 232 Th concentration was determined from the weighted average concentrations of 228 Ac, 212 Pb and 212 Bi and the 40 K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg -1 to 222 Bq.kg -1 for 226 Ra and from 14 Bq.kg -1 to 1074 Bq.kg -' 1 for 232 Th, both with the highest values for Camburi South and Central. For 40 K, the activity concentrations ranged from 14 Bq.kg -1 to 179 Bq.kg -1 and the highest values were obtained for Camburi South. (author)

  12. The thermoluminescence response of Ge-doped flat fibre for proton beam measurements: A preliminary study

    International Nuclear Information System (INIS)

    Hassan, M F; Fadzil, M S Ahmad; Noor, N Mohd; Abdul Rahman, W N Wan; Tominaga, T; Geso, M; Akasaka, H; Bradley, D A

    2017-01-01

    The aim of this study was to investigate the thermoluminescence (TL) response of fabricated 2.3 mol% and 6.0 mol% germanium (Ge) doped flat optical fibres to proton irradiation. The fundamental dosimetric characteristics of the fibres have been investigated including dose linearity, reproducibility and fading. The thermoluminescent dosimeters (TLDs) were used as a reference dosimeter to allow the relative response of the fibres. The results show that Ge-doped flat fibres offer excellent dose linearity over the dose range from 1 Gy up to 10 Gy with correlation of determination (R 2 ) of 0.99. The fibres also demonstrated good reproducibility within the standard deviation (SD) of 0.86% to 6.41%. After 96 days post-irradiation, TLD-100 chips gave rise to the least loss in TL signal at around 18% followed by fabricated 2.3 mol% Ge-doped flat fibres about 24%. This preliminary study has demonstrated that the proposed fabricated Ge-doped flat fibre offers a promising potential for use in proton beam measurements. (paper)

  13. Preliminary results from the MEMO multicomponent measurements of waves on-board INTERBALL 2

    Directory of Open Access Journals (Sweden)

    F. Lefeuvre

    Full Text Available The MEMO (MEsure Multicomposante des Ondes experiment is a part of the INTERBALL 2 wave consortium. It is connected to a total of six electric and nine magnetic independent sensors. It provides waveforms associated with the measurement of two to five components in three frequency bands: ELF (5–1000 Hz, VLF (1–20 kHz, LF (20–250 kHz. Preliminary analyses of low and high resolution data are presented. The emphasis is put on the estimation of the propagation characteristics of the observed waves.VLF hiss emissions are shown to be mainly whistler mode emissions, but other modes are present. An accurate estimation of the local plasma frequency is proposed when the low L = 0 cutoff frequency is identified. AKR emissions observed just above source regions are studied. R-X and L-O modes are found: the first at the lowest frequencies and the second at the highest. Both propagate with wave normal directions weakly oblique or quasi-parallel to the Earth's magnetic field direction. Propagation characteristics are also determined for a (non-drifting fine structure of AKR. There is no fundamental difference with structurless events. Nightside and dayside bursts of ELF electromagnetic emissions are presented. It is not clear whether the two emissions belong to the "lion roar" emissions or not.

    Key words. Magnetospheric physics (auroral phenomena; plasma waves and instabilities; instruments and techniques

  14. Preliminary results from the MEMO multicomponent measurements of waves on-board INTERBALL 2

    Directory of Open Access Journals (Sweden)

    F. Lefeuvre

    1998-09-01

    Full Text Available The MEMO (MEsure Multicomposante des Ondes experiment is a part of the INTERBALL 2 wave consortium. It is connected to a total of six electric and nine magnetic independent sensors. It provides waveforms associated with the measurement of two to five components in three frequency bands: ELF (5–1000 Hz, VLF (1–20 kHz, LF (20–250 kHz. Preliminary analyses of low and high resolution data are presented. The emphasis is put on the estimation of the propagation characteristics of the observed waves.VLF hiss emissions are shown to be mainly whistler mode emissions, but other modes are present. An accurate estimation of the local plasma frequency is proposed when the low L = 0 cutoff frequency is identified. AKR emissions observed just above source regions are studied. R-X and L-O modes are found: the first at the lowest frequencies and the second at the highest. Both propagate with wave normal directions weakly oblique or quasi-parallel to the Earth's magnetic field direction. Propagation characteristics are also determined for a (non-drifting fine structure of AKR. There is no fundamental difference with structurless events. Nightside and dayside bursts of ELF electromagnetic emissions are presented. It is not clear whether the two emissions belong to the "lion roar" emissions or not.Key words. Magnetospheric physics (auroral phenomena; plasma waves and instabilities; instruments and techniques

  15. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric fields

    International Nuclear Information System (INIS)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast intensified charge-coupled device (ICCD) imaging of the development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of the electric field in the discharge. The uniformity of the discharge images obtained with nanosecond exposure times was analysed using chi-square test. The results indicate that DBD uniformity strongly depends on the applied (global) electric field in the discharge gap, which is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is a transition from filamentary to uniform DBD mode that correlates to the corresponding decrease of the maximum local electric field in the discharge. (fast track communication)

  16. Uniform and non-uniform modes of nanosecond-pulsed dielectric barrier discharge in atmospheric air: fast imaging and spectroscopic measurements of electric field

    Science.gov (United States)

    Liu, Chong; Dobrynin, Danil; Fridman, Alexander

    2014-01-01

    In this study, we report experimental results on fast ICCD imaging of development of nanosecond-pulsed dielectric barrier discharge (DBD) in atmospheric air and spectroscopic measurements of electric field in the discharge. Uniformity of the discharge images obtained with nanosecond exposure times were analyzed using chi-square test. The results indicate that DBD uniformity strongly depends on applied (global) electric field in the discharge gap, and is a threshold phenomenon. We show that in the case of strong overvoltage on the discharge gap (provided by fast rise times), there is transition from filamentary to uniform DBD mode which correlates to the corresponding decrease of maximum local electric field in the discharge. PMID:25071294

  17. Preliminary results of aerosols' properties studied with EPF measurements from the SPICAM/UV instrument

    Science.gov (United States)

    Willame, Yannick; Carine Vandaele, Ann; Depiesse, Cedric; Gillotay, Didier; Kochenova, Svetlana; Montmessin, Franck

    2013-04-01

    Aerosols on Mars have an important impact on the radiative transfer properties of its atmosphere. Today their spectral properties and therefore their interaction with UV radiation are only poorly known. Improving the radiative transfer modeling requires a better knowledge of their characteristics, in particular of their opacity, phase function and single scattering albedo. Part of such information can be accessed by using EPF observations. The SPICAM instrument on board of the Mars-Express satellite is a 2 channel spectrometer. One channel operates in the ultraviolet (118-320 nm) and the second one in the infrared (1.0-1.7μm). SPICAM has been orbiting around the red planet since 2003 and has thus provided a large set of data. The instrument is capable of measuring under different geometries (nadir, limb, occultation) and one of them, called EPF (Emission Phase Function), can be a tool to study aerosols' properties. We have developed a new retrieval algorithm for nadir measurements based on the radiative transfer model LIDORT. This new code performs simulations of spectra taking into account gas absorption, surface reflection and scattering by aerosols and gases. The retrieval method, based on the optimal estimation, allows us up to now to deduce the ozone column density, the aerosols' optical depth and the surface albedo (with fixed wavelength dependencies). We are developing our model further in order to better study the aerosols' characteristics using EPF observations, which consist in looking at the same point on the planet while the satellite moves along the orbit. As the attempt to study all the aerosols' properties simultaneously was not convincing, we started studying their opacity and the influence of its altitude distribution with the other characteristics fixed. We will present preliminary results of our study on aerosols' properties using EPF data from SPICAM.

  18. RAPID3 scores and hand outcome measurements in RA patients: a preliminary study.

    Science.gov (United States)

    Qorolli, Merita; Hundozi-Hysenaj, Hajrije; Rexhepi, Sylejman; Rehxepi, Blerta; Grazio, Simeon

    2017-06-01

    The Routine Assessment of Patient Index Data 3 (RAPID3) is a patient-reported disease activity measure used to assess physical function, pain, and global health in patients with rheumatoid arthritis (RA) without formal joint counts. Since hand involvement and its decreased function are hallmarks of RA, the aim of our study was to investigate the performance of RAPID3 scores with regard to hand function and to confirm previous findings that the RAPID3 score as a disease activity measure is strongly correlated with the DAS28 score. Sixty-eight consecutive patients with RA (85% female), aged 18-75 years, were included in the study and were recruited during their outpatient visit. Apart from demographic and clinical data, the obtained parameters of interest included RAPID3 scores and assessments of the function of the hand, namely, the signal of functional impairment (SOFI)-hand, grip strength, and pulp-to-palm distance, as well the Health Assessment Questionnaire- Disability Index (HAQ-DI) and DAS28 scores. Pearson's correlation coefficient, Student's t test and linear regression were used in the statistical analysis of the results. The significance was set to p < 0.05. A positive correlation was found between RAPID3 scores and HAQ-DI scores, SOFI-hand scores, and pulp-to-palm distance, and negative correlation was observed between RAPID3 scores and grip strength. The order regarding the strength of correlations between RAPID3 scores and other variables (from the strongest to the weakest) was as follows: HAQ-DI, grip strength, SOFI-hand and pulp-to-palm distance. The hand assessment variables had stronger correlations with RAPID3 scores than with DAS28 scores. Our preliminary study showed that RAPID3 scores were strongly correlated with measurements of the functional ability of the hand, demonstrating that RAPID3 can be used as a measure of disease activity in clinical practice and to characterize hand function. Further studies are needed to confirm this result.

  19. Preliminary spectroscopic characterization of PEGylated mucin, a ...

    African Journals Online (AJOL)

    The matrices were characterized with respect to compatibility using the Fourier transform infrared (FT-IR) spectroscopy. Results of the qualitative tests performed on the snail mucin showed that carbohydrates, proteins and trace amounts of fats were present; the extracted mucin was light-brownish in colour, with a pleasant ...

  20. Preliminary spectroscopic characterization of PEGylated mucin, a ...

    African Journals Online (AJOL)

    Frank

    2013-11-20

    Nov 20, 2013 ... Drug delivery can be of importance for both new chemical entities as well as ... on account of their stability or their absorption from the. GIT thus leading to ... 1991). To reduce the impact of digestive enzymes and ensure the ...

  1. Measurements of the aerosol chemical composition and mixing state in the Po Valley using multiple spectroscopic techniques

    Science.gov (United States)

    Decesari, S.; Allan, J.; Plass-Duelmer, C.; Williams, B. J.; Paglione, M.; Facchini, M. C.; O'Dowd, C.; Harrison, R. M.; Gietl, J. K.; Coe, H.; Giulianelli, L.; Gobbi, G. P.; Lanconelli, C.; Carbone, C.; Worsnop, D.; Lambe, A. T.; Ahern, A. T.; Moretti, F.; Tagliavini, E.; Elste, T.; Gilge, S.; Zhang, Y.; Dall'Osto, M.

    2014-11-01

    The use of co-located multiple spectroscopic techniques can provide detailed information on the atmospheric processes regulating aerosol chemical composition and mixing state. So far, field campaigns heavily equipped with aerosol mass spectrometers have been carried out mainly in large conurbations and in areas directly affected by their outflow, whereas lesser efforts have been dedicated to continental areas characterised by a less dense urbanisation. We present here the results obtained at a background site in the Po Valley, Italy, in summer 2009. For the first time in Europe, six state-of-the-art spectrometric techniques were used in parallel: aerosol time-of-flight mass spectrometer (ATOFMS), two aerosol mass spectrometers (high-resolution time-of-flight aerosol mass spectrometer - HR-ToF-AMS and soot particle aerosol mass spectrometer - SP-AMS), thermal desorption aerosol gas chromatography (TAG), chemical ionisation mass spectrometry (CIMS) and (offline) proton nuclear magnetic resonance (1H-NMR) spectroscopy. The results indicate that, under high-pressure conditions, atmospheric stratification at night and early morning hours led to the accumulation of aerosols produced by anthropogenic sources distributed over the Po Valley plain. Such aerosols include primary components such as black carbon (BC), secondary semivolatile compounds such as ammonium nitrate and amines and a class of monocarboxylic acids which correspond to the AMS cooking organic aerosol (COA) already identified in urban areas. In daytime, the entrainment of aged air masses in the mixing layer is responsible for the accumulation of low-volatility oxygenated organic aerosol (LV-OOA) and also for the recycling of non-volatile primary species such as black carbon. According to organic aerosol source apportionment, anthropogenic aerosols accumulating in the lower layers overnight accounted for 38% of organic aerosol mass on average, another 21% was accounted for by aerosols recirculated in

  2. Gamma spectroscopic studies of the neutron-deficient g-g nucleus 74Kr by means of a neutron multiplicity measurement technique

    International Nuclear Information System (INIS)

    Roth, J.

    1981-01-01

    The g-g nucleus 74 Kr was studied by means of the reaction 58 Ni ( 19 F, p2n#betta#) 74 Kr. In order to make gamma spectroscopic studies at neutron deficient nuclei like 74 Kr a neutron multiplicity measurement technique was developed. Beside #betta# single spectra, #betta# excitation functions, #betta#-#betta# coincidences, #betta# angular distributions, and lifetime measurements by means of this technique all measurements in coincidence with up to two neutrons were taken up. From these measurement data an extended term scheme with 17 newly found excited states could be extracted. To all levels spins and parities could be assigned. From the four energetically lowest levels of the yrast cascade the mean lifetimes could be determined. A double backbending in the sequence of the yrast cascade was interpreted as crossing of the g 9/2 bands. The irregularities in the lower part of the yrast band correspond to the shape consistence picture. The results were considered in connection with the systematics of the even krypton isotopes and compared with a two-quasiparticle-plas-rotor model calculation. (HSI)

  3. Black Carbon in Arctic Snow: Preliminary Results from Recent Field Measurements

    Science.gov (United States)

    Warren, S. G.; Grenfell, T. C.; Radionov, V. F.; Clarke, A. D.

    2007-12-01

    Annual snowpacks act to amplify variations in regional solar heating of the surface due to positive feedback processes associated with areal melting and precipitation. Small amounts of black carbon (BC) in the snow can reduce the albedo and modulate shortwave absorption and transmission affecting the onset of melt and heating of the snow pack. The effect of black carbon on the albedo of snow in the Arctic is estimated to be up to a few percent. The only prior survey of arctic snow was that of Clarke and Noone in 1983-84. We have begun a wide- area survey of the BC content of arctic snow in order to update and expand the 1983/84 survey. Samples of snow have been collected in mid to late spring when the entire winter snowpack was accessible. The samples have been melted and filtered, and the filters analyzed for absorptive impurities. To date, sites in Alaska, Canada, Greenland, and in the Arctic Basin have been sampled. In March and April 2007 we also carried out a field program at four sites in northwestern Russia as part of the International Polar Year. Preliminary results based on visual comparison with the standard filters indicate that the snow cover in arctic North America and the Beaufort Sea have lower BC concentrations now than 20 years ago while levels in Greenland are about the same. Background levels of BC in Russia are approximately twice those in North America consistent with modeling predictions of Flanner et al., 2007. More accurate values of absorption will be obtained by measurement of spectral transmission of the filters, which will also allow the relative contributions of BC and soil dust to be determined.

  4. Noninvasive measurement of cerebrospinal fluid flow using an ultrasonic transit time flow sensor: a preliminary study.

    Science.gov (United States)

    Pennell, Thomas; Yi, Juneyoung L; Kaufman, Bruce A; Krishnamurthy, Satish

    2016-03-01

    OBJECT Mechanical failure-which is the primary cause of CSF shunt malfunction-is not readily diagnosed, and the specific reasons for mechanical failure are not easily discerned. Prior attempts to measure CSF flow noninvasively have lacked the ability to either quantitatively or qualitatively obtain data. To address these needs, this preliminary study evaluates an ultrasonic transit time flow sensor in pediatric and adult patients with external ventricular drains (EVDs). One goal was to confirm the stated accuracy of the sensor in a clinical setting. A second goal was to observe the sensor's capability to record real-time continuous CSF flow. The final goal was to observe recordings during instances of flow blockage or lack of flow in order to determine the sensor's ability to identify these changes. METHODS A total of 5 pediatric and 11 adult patients who had received EVDs for the treatment of hydrocephalus were studied in a hospital setting. The primary EVD was connected to a secondary study EVD that contained a fluid-filled pressure transducer and an in-line transit time flow sensor. Comparisons were made between the weight of the drainage bag and the flow measured via the sensor in order to confirm its accuracy. Data from the pressure transducer and the flow sensor were recorded continuously at 100 Hz for a period of 24 hours by a data acquisition system, while the hourly CSF flow into the drip chamber was recorded manually. Changes in the patient's neurological status and their time points were noted. RESULTS The flow sensor demonstrated a proven accuracy of ± 15% or ± 2 ml/hr. The flow sensor allowed real-time continuous flow waveform data recordings. Dynamic analysis of CSF flow waveforms allowed the calculation of the pressure-volume index. Lastly, the sensor was able to diagnose a blocked catheter and distinguish between the blockage and lack of flow. CONCLUSIONS The Transonic flow sensor accurately measures CSF output within ± 15% or ± 2 ml

  5. Measuring the tridosha symptoms of unmāda (psychosis): a preliminary study.

    Science.gov (United States)

    Suchitra, Sureshrao P; Devika, Honagalli S; Gangadhar, Bangalore N; Nagarathna, Raghuram; Nagendra, Hongasamudra R; Kulkarni, Ravi

    2010-04-01

    This is a preliminary report on the development of a scale to measure the symptoms of unmāda (psychosis) attributable to tridosa (metabolic principles) by using the concepts of Ayurvedic medicine. The 67-item unmāda specific symptom scale was developed on the basis of translation of Sanskrit verses describing vātaja (V), pittaja (P), and kaphaja (K) unmāda (specific symptoms of psychosis due to the imbalances of metabolic components) and by taking the opinions of experts (15 Ayurveda experts, 5 psychiatrists, and 5 psychologists). The setting for this study was Spandana Psychiatric Nursing Home Bangalore, India. The scale was administered by an unblinded assessor to 30 consecutive patients with nonaffective psychotic disorders. The unmāda specific symptom scale was associated with excellent internal consistency. The Cronbach's alpha for V, P, and K scales were 0.98, 0.98, and 0.97, respectively. The split-half reliability for V, P, and K scales were 0.97, 0.97, and 0.88 respectively. Scores on vātaja, pittaja, and kaphaja scales were inversely correlated, suggesting that they are mutually exclusive. The three subgroups of psychoses--paranoid schizophrenia, schizophrenia (unspecified), and unspecified nonorganic psychosis--had significantly different loadings on the three scores, having high scores on vātaja, pittaja, and kaphaja, respectively. The tridoshas in psychotic disorders can be measured reliably by this instrument. The scores on each of these doşas help in differentiating three types of psychosis (according to Ayurveda) that have good correspondence with prevailing classification. However, this scale must also be applied to the other 28 separate subcategories of the psychoses that are identified in the International Statistical Classifications of Diseases (version 10) and to the 10 variants of psychosis as defined by the American Psychiatric Association Diagnostic and Statistical Manual-IV-R to help better understand the true utility for use here

  6. Preliminary Broadband Measurements of Dielectric Permittivity of Planetary Regolith Analog Materials Using a Coaxial Airline

    Science.gov (United States)

    Boivin, A.; Tsai, C. A.; Ghent, R. R.; Daly, M. G.

    2014-12-01

    When considering radar observations of airless bodies containing regolith, the radar backscatter coefficient is dependent upon the complex dielectric permittivity of the regolith materials. In many current applications of imaging radar data, uncertainty in the dielectric permittivity precludes quantitative estimates of such important parameters as regolith thickness and depth to buried features (e.g., lava flows on the Aristarchus Plateau on the Moon and the flows that surround the Quetzalpetlatl Corona on Venus). For asteroids, radar is an important tool for detecting and characterizing regoliths. Many previous measurements of the real and/or complex parts of the dielectric permittivity have been made, particularly for the Moon (on both Apollo samples and regolith analogues). However, no studies to date have systematically explored the relationship between permittivity and the various mineralogical components such as presence of FeO and TiO2. For lunar materials, the presence of the mineral ilmenite (FeTiO3), which contains equal portions FeO and TiO2, is thought to be the dominant factor controlling the loss tangent (tanδ, the ratio of the imaginary and real components of the dielectric permittivity). Ilmenite, however, is not the only mineral to contain iron in the lunar soil and our understanding of the effect of iron on the loss tangent is insufficient. Beyond the Moon, little is known about the effects on permittivity of carbonaceous materials. This is particularly relevant for missions to asteroids, such as the OSIRIS-REx mission to (101955) Bennu, a carbonaceous asteroid whose regolith composition is largely unknown. Here we present preliminary broadband (300 Mhz to 14 GHz) measurements on materials intended as planetary regolith analogs. Our ultimate goal is to establish a database of the effects of a wide range mineralogical components on dielectric permittivity, in support of the OSIRIS REx mission and ongoing Earth-based radar investigation of the Moon

  7. Accounting for the measurement error of spectroscopically inferred soil carbon data for improved precision of spatial predictions.

    Science.gov (United States)

    Somarathna, P D S N; Minasny, Budiman; Malone, Brendan P; Stockmann, Uta; McBratney, Alex B

    2018-08-01

    Spatial modelling of environmental data commonly only considers spatial variability as the single source of uncertainty. In reality however, the measurement errors should also be accounted for. In recent years, infrared spectroscopy has been shown to offer low cost, yet invaluable information needed for digital soil mapping at meaningful spatial scales for land management. However, spectrally inferred soil carbon data are known to be less accurate compared to laboratory analysed measurements. This study establishes a methodology to filter out the measurement error variability by incorporating the measurement error variance in the spatial covariance structure of the model. The study was carried out in the Lower Hunter Valley, New South Wales, Australia where a combination of laboratory measured, and vis-NIR and MIR inferred topsoil and subsoil soil carbon data are available. We investigated the applicability of residual maximum likelihood (REML) and Markov Chain Monte Carlo (MCMC) simulation methods to generate parameters of the Matérn covariance function directly from the data in the presence of measurement error. The results revealed that the measurement error can be effectively filtered-out through the proposed technique. When the measurement error was filtered from the data, the prediction variance almost halved, which ultimately yielded a greater certainty in spatial predictions of soil carbon. Further, the MCMC technique was successfully used to define the posterior distribution of measurement error. This is an important outcome, as the MCMC technique can be used to estimate the measurement error if it is not explicitly quantified. Although this study dealt with soil carbon data, this method is amenable for filtering the measurement error of any kind of continuous spatial environmental data. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A Combination of Preliminary Electroweak Measurements and Constraints on the Standard Model

    DEFF Research Database (Denmark)

    Hansen, Jørgen Beck

    2001-01-01

    This note presents a combination of published and preliminary electroweak results from the four LEP collaborations and the SLD collaboration which were prepared for the 2000 summer conferences. Averages from Z0 resonance results are derived for hadronic and leptonic cross sections, the leptonic f...

  9. Fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging: Toward robust and reproducible metabolite measurements in human brain.

    Science.gov (United States)

    Bian, Wei; Li, Yan; Crane, Jason C; Nelson, Sarah J

    2018-02-01

    To implement a fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging (MRSI). The PRESS selected volume and outer-volume suppression bands were predefined on the MNI152 standard template image. The template image was aligned to the subject T 1 -weighted image during a scan, and the resulting transformation was then applied to the predefined prescription. To evaluate the method, H-1 MRSI data were obtained in repeat scan sessions from 20 healthy volunteers. In each session, datasets were acquired twice without repositioning. The overlap ratio of the prescribed volume in the two sessions was calculated and the reproducibility of inter- and intrasession metabolite peak height and area ratios was measured by the coefficient of variation (CoV). The CoVs from intra- and intersession were compared by a paired t-test. The average overlap ratio of the automatically prescribed selection volumes between two sessions was 97.8%. The average voxel-based intersession CoVs were less than 0.124 and 0.163 for peak height and area ratios, respectively. Paired t-test showed no significant difference between the intra- and intersession CoVs. The proposed method provides a time efficient method to prescribe 3D PRESS MRSI with reproducible imaging positioning and metabolite measurements. Magn Reson Med 79:636-642, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Spectroscopic methods

    International Nuclear Information System (INIS)

    Ivanovich, M.; Murray, A.

    1992-01-01

    The principles involved in the interaction of nuclear radiation with matter are described, as are the principles behind methods of radiation detection. Different types of radiation detectors are described and methods of detection such as alpha, beta and gamma spectroscopy, neutron activation analysis are presented. Details are given of measurements of uranium-series disequilibria. (UK)

  11. High-accuracy and high-sensitivity spectroscopic measurement of dinitrogen pentoxide (N2O5) in an atmospheric simulation chamber using a quantum cascade laser.

    Science.gov (United States)

    Yi, Hongming; Wu, Tao; Lauraguais, Amélie; Semenov, Vladimir; Coeur, Cecile; Cassez, Andy; Fertein, Eric; Gao, Xiaoming; Chen, Weidong

    2017-12-04

    A spectroscopic instrument based on a mid-infrared external cavity quantum cascade laser (EC-QCL) was developed for high-accuracy measurements of dinitrogen pentoxide (N 2 O 5 ) at the ppbv-level. A specific concentration retrieval algorithm was developed to remove, from the broadband absorption spectrum of N 2 O 5 , both etalon fringes resulting from the EC-QCL intrinsic structure and spectral interference lines of H 2 O vapour absorption, which led to a significant improvement in measurement accuracy and detection sensitivity (by a factor of 10), compared to using a traditional algorithm for gas concentration retrieval. The developed EC-QCL-based N 2 O 5 sensing platform was evaluated by real-time tracking N 2 O 5 concentration in its most important nocturnal tropospheric chemical reaction of NO 3 + NO 2 ↔ N 2 O 5 in an atmospheric simulation chamber. Based on an optical absorption path-length of L eff = 70 m, a minimum detection limit of 15 ppbv was achieved with a 25 s integration time and it was down to 3 ppbv in 400 s. The equilibrium rate constant K eq involved in the above chemical reaction was determined with direct concentration measurements using the developed EC-QCL sensing platform, which was in good agreement with the theoretical value deduced from a referenced empirical formula under well controlled experimental conditions. The present work demonstrates the potential and the unique advantage of the use of a modern external cavity quantum cascade laser for applications in direct quantitative measurement of broadband absorption of key molecular species involved in chemical kinetic and climate-change related tropospheric chemistry.

  12. TWO STARS TWO WAYS: CONFIRMING A MICROLENSING BINARY LENS SOLUTION WITH A SPECTROSCOPIC MEASUREMENT OF THE ORBIT

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Jennifer C.; Johnson, John Asher; Eastman, Jason; Vanderburg, Andrew [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Skowron, Jan [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, Andrew [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Pineda, J. Sebastian [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, MC 249-17, Pasadena, CA 91125 (United States); Howard, Andrew, E-mail: jyee@cfa.harvard.edu, E-mail: jjohnson@cfa.harvard.edu, E-mail: jason.eastman@cfa.harvard.edu, E-mail: avanderburg@cfa.harvard.edu [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822-1839 (United States)

    2016-04-20

    Light curves of microlensing events involving stellar binaries and planetary systems can provide information about the orbital elements of the system due to orbital modulations of the caustic structure. Accurately measuring the orbit in either the stellar or planetary case requires detailed modeling of subtle deviations in the light curve. At the same time, the natural, Cartesian parameterization of a microlensing binary is partially degenerate with the microlens parallax. Hence, it is desirable to perform independent tests of the predictions of microlens orbit models using radial velocity (RV) time series of the lens binary system. To this end, we present 3.5 years of RV monitoring of the binary lens system OGLE-2009-BLG-020 L, for which Skowron et al. constrained all internal parameters of the 200–700 day orbit. Our RV measurements reveal an orbit that is consistent with the predictions of the microlens light curve analysis, thereby providing the first confirmation of orbital elements inferred from microlensing events.

  13. Measurement of the non-thermal properties of a low pressure spraying plasma by electric and spectroscopic methods

    International Nuclear Information System (INIS)

    Jung, Yong Ho

    2003-02-01

    For the case of an atmospheric plasma, the local thermodynamic equilibrium (LTE) model can be applied to plasmas at a nozzle entrance and to those on the axis of the plasma flame, but it is not easy to justify applying the LTE model to off-center plasma and to a low-pressure spraying plasma. Although the energy distribution of the electrons is assumed to be Maxwellian for the most of spraying plasmas, the non-Maxwellian distribution is possible for the case of low-pressure spaying plasma and edge plasma of atmospheric spraying plasma. In this work, the non-Maxwellian distribution of electrons was measured by using an electric probe installed on the fast scanning probe system, and non-LTE effects were measured by using the optical emission spectroscopy system. Distribution of the electrons of a low-pressure spraying plasma is observed not as Maxwellian but as bi-Maxwellian by the measurement of the single probe. Bi-Maxwellian distribution appears in the edge of a low pressure spraying plasma and seems to be due to the reduction of the collisonality by the drastic variation of the plasma density. Non-LTE characteristics of a low-pressure spraying plasma can be deuced from the measured results of the optical emission spectroscopy and is analyzed by the collisional radiative equilibrium (CRE) model, where the Maxwellian and the non-Maxwellian distributions are assumed for comparison. For the electron temperature, the results from optical emission spectroscopy were similar to the results from the single probe (3∼5 % in error)

  14. Presentation of a methodology for measuring social acceptance of three hydrogen storage technologies and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noirot, I.; Bigay, C. N.

    2005-07-01

    Hydrogen storage is a key technology for the extensive use of H2 as energy carrier. As none of the current technologies satisfies all of the hydrogen storage attributes required by manufacturers and end users, there is intense research works aiming at developing viable solutions. A broad objective of the StorHy European project is to provide technological storage solutions, which are attractive from an economical, environmental and safety point of view. A specific sub-project is dedicated to the comparison of three different potential storage technologies for transport applications (compressed gas, cryogenic liquid, solid media). This evaluation is carried out in a harmonised way, based on common tools and assessment strategies that could be useful for decision makers and stakeholders. The assessment is achieved in a 'sustainable development' spirit, taking into consideration the technical, environmental, economical, safety and social requirements. The latter ones have newly emerged in such evaluations, based on the Quality Function Deployment (QFD) approach, and would require to be further studied. Hydrogen acceptability studies have been conducted in previous projects. They have been reviewed by LBST in the AcceptH2 project Public acceptance of Hydrogen Transport Technologies : Analysis and comparisons of existing studies (www. accepth2. com - August 2003). During these hydrogen acceptance surveys, mainly fuel cell bus passengers from demonstration projects around the world have been questioned. The work presented in this paper goes further in the methodology refinement as it focuses on the evaluation of hydrogen storage solutions. It proposes a methodological tool for efficient social evaluation of new technologies and associated preliminary results concerning France. In a global approach to sustainable development, the CEA has developed a new methodology to evaluate its current research projects : Multicriteria Analysis for Sustainable Industrial

  15. Microscopic studies of a SnO2/α-Fe2O3 architectural nanocomposite using Moessbauer spectroscopic and magnetic measurements

    International Nuclear Information System (INIS)

    Hayashi, Naoaki; Muranaka, Shigetoshi; Yamamoto, Shinpei; Takano, Mikio; Zhang Dongfeng; Sun Lingdong; Yan Chunhua

    2008-01-01

    A SnO 2 /α-Fe 2 O 3 architectural nanocomposite, which was evidenced as SnO 2 nanorod arrays assembled on the surface of α-Fe 2 O 3 nanotubes in our previous study, was investigated microscopically by means of Moessbauer spectroscopic and magnetic measurements. It was found for the SnO 2 nanorods that Fe 3+ ions substituted slightly to Sn 0.998 Fe 0.002 O 2 . Concerning the α-Fe 2 O 3 tubes, the Morin transition, which was completely suppressed in the mother, SnO 2 -free α-Fe 2 O 3 nanotubes, was found to be recovered locally. We speculate that it takes place in the interface area as a result of structural modification needed for the connection with the SnO 2 nanorods. - Graphic abstract: 57 Fe Moessbauer spectrum of SnO 2 /α-Fe 2 O 3 architectural nanocomposite evidenced as SnO 2 nanorod arrays assembled on the surface of α-Fe 2 O 3 nanotubes. (I: Fe-doped SnO 2 nanorods, II: α-Fe 2 O 3 nanotubes) It was found for the SnO 2 nanorods that Fe 3+ ions substituted slightly to Sn 0.998 Fe 0.002 O 2

  16. Raman spectroscopic studies of isotopic diatomic molecules and a technique for measuring stable isotope ratios using Raman scattering

    International Nuclear Information System (INIS)

    Harney, R.C.

    1976-01-01

    A method for measuring stable isotope ratios using Raman scattering has been developed. This method consists of simultaneously counting photons scattered out of a high-intensity laser beam by different isotopically-substituted molecules. A number of studies of isotopic diatomic molecules have been made. The Q-branches of the Raman spectra of the isotopic molecules 14 N 15 N and 16 O 18 O were observed at natural abundance in nitrogen and oxygen samples. Comparison of the ratios of the intensities of the Q-branches of the major nitrogen and oxygen isotopic molecules with mass spectrometric determinations of the isotopic compositions yielded scattering cross sections of 14 N 15 N relative to 14 N 14 N and 16 O 18 O relative to 16 O 16 O. These cross section ratios differ from unity, a difference which can be explained by considering nuclear mass effects on the Franck-Condon factors of the molecular transitions. The measured intensities of the 14 N 15 N and 16 O 18 O Q-branches provided the baseline data needed to make the previously-mentioned extrapolation. High-resolution (approximately 0.15 cm -1 ) spectra of the Q-branches of 14 N 14 N and 16 O 16 O yielded a direct determination of α/sub e/ (the difference between the rotational constant in the ground and first excited vibrational states) for these molecules. The measured values are in excellent agreement with those obtained by other means. Complete Raman spectra (pure rotation, rotation-vibration, and high-resolution Q-branch) were obtained on a sample of pure 18 O 18 O. Analysis of this data yielded the molecular parameters: the equilibrium internuclear separation r/sub e/, the moment of inertia I/sub e/, and the energy parameters α/sub e/, B/sub e/, and ΔG/sub 1 / 2 /. These are in good agreement with data obtained by microwave spectroscopy

  17. Air Mass Factor Formulation for Spectroscopic Measurements from Satellites: Application to Formaldehyde Retrievals from the Global Ozone Monitoring Experiment

    Science.gov (United States)

    Palmer, Paul I.; Jacob, Daniel J.; Chance, Kelly; Martin, Randall V.; Spurr, Robert J. D.; Kurosu, Thomas P.; Bey, Isabelle; Yantosca, Robert; Fiore, Arlene; Li, Qinbin

    2004-01-01

    We present a new formulation for the air mass factor (AMF) to convert slant column measurements of optically thin atmospheric species from space into total vertical columns. Because of atmospheric scattering, the AMF depends on the vertical distribution of the species. We formulate the AMF as the integral of the relative vertical distribution (shape factor) of the species over the depth of the atmosphere, weighted by altitude-dependent coefficients (scattering weights) computed independently from a radiative transfer model. The scattering weights are readily tabulated, and one can then obtain the AMF for any observation scene by using shape factors from a three dimensional (3-D) atmospheric chemistry model for the period of observation. This approach subsequently allows objective evaluation of the 3-D model with the observed vertical columns, since the shape factor and the vertical column in the model represent two independent pieces of information. We demonstrate the AMF method by using slant column measurements of formaldehyde at 346 nm from the Global Ozone Monitoring Experiment satellite instrument over North America during July 1996. Shape factors are cumputed with the Global Earth Observing System CHEMistry (GEOS-CHEM) global 3-D model and are checked for consistency with the few available aircraft measurements. Scattering weights increase by an order of magnitude from the surface to the upper troposphere. The AMFs are typically 20-40% less over continents than over the oceans and are approximately half the values calculated in the absence of scattering. Model-induced errors in the AMF are estimated to be approximately 10%. The GEOS-CHEM model captures 50% and 60% of the variances in the observed slant and vertical columns, respectively. Comparison of the simulated and observed vertical columns allows assessment of model bias.

  18. Measurement of the Spectroscopic Quadrupole Moment for the 2+1 State in 10Be:. Testing AB Initio Calculations

    Science.gov (United States)

    Orce, J. N.; Djongolov, M.; Navratil, P.; Ball, G.; Garnsworthy, A. B.; Hackman, G.; Lassen, J.; Meissner, J.; Pearson, C. J.; Li, R.; Milovanovic, L.; Sjue, S. K. L.; Teigelhoefer, A.; Triambak, S.; Williams, S. J.; Falou, H. Al; Drake, T. E.; Andreoiu, C.; Cross, D.; Kshetri, R.; Finlay, P.; Garrett, P. E.; Leach, K. G.; Rand, E. T.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Wong, J.; Forssen, C.; Hayes, A. B.; Sarazin, F.; Stoyer, M. A.; Wu, C. Y.

    2013-03-01

    The highly efficient and segmented TIGRESS HPGe γ-ray array at TRIUMF has been used to perform a reorientation effect Coulomb excitation study of the 2+1 state at 3.368 MeV in 10Be. This is the first Coulomb excitation measurement that provides information on diagonal matrix elements for such a high lying first excited state from μ-ray data. With the availability of accurate lifetime data, a restriction on the diagonal matrix element is determined. This result is compared to a no core shell model calculation with the CD-Bonn 2000 two nucleon potential.

  19. Soft X-Ray Spectroscopic Measurements of Plasma Conditions at Early Times in ICF Experiments on OMEGA. Final technical report

    International Nuclear Information System (INIS)

    Griem, Hans R.; Elton, Raymond C.

    2000-01-01

    Our previously-reported observation of a disruptive prepulse on OMEGA, possibly as large as 1% of the extreme ultraviolet (euv) radiation measured from the main pulse, has recently been substantiated by the measurement of euv absorption spectra, prior to the main pulse. The absorption features have been identified with n=2 photoionization in aluminum atoms and ions up to Al5+. Cold aluminum is originally present as a 0.0125-um thick sealant coating applied to a neon-filled (10 atm) CH microballoon, with an euv transmission at the L-absorption edge of ∼50%. The aluminum in turn is overcoated with 2 um of Mg. The spectra which show the absorption also include continua as well as line emissions from Mg9+ to Mg11+ ions. These occur prior to the onset of laser target irradiation by at least 10 ns, and imply a prepulse irradiance of about 10 12 W/cm 2 . Since the neon and CH are opaque to euv radiation from the rear, a likely scenario is early (prepulse) vaporization of the outer Mg layer, perhaps in hot spots, followed by laser radiation transmitted through the thin Al layer, thereby heating the CH surface. This could provide an euv continuum backlighter for the aluminum that leads to the euv absorption features in various ionic species, perhaps from different points on the target surface

  20. Fluoro-apatite surface composition in aqueous solution deduced from potentiometric, electrokinetic, and solubility measurements, and spectroscopic observations

    International Nuclear Information System (INIS)

    Chairat, C.; Oelkers, E.H.; Schott, J.; Lartigue, J.E.

    2007-01-01

    The surface chemistry of fluoro-apatite in aqueous solution was investigated using electrokinetic techniques, potentiometric titrations, solubility measurements, and attenuated total reflection infrared spectroscopy. All methods indicate the formation of Ca/F depleted, P enriched altered layer via exchange reactions between H + and Ca 2+ , and OH - and F - at the fluoro-apatite (FAP) surface. Observations suggest that this leached layer has a di-calcium phosphate (CaHPO 4 ) composition and that it controls the apparent solubility of FAP. Electrokinetic measurements yield an iso-electric point value of 1 ± 0.5 consistent with a negatively charged FAP surface at pH ≥ 1. In contrast, surface titrations give an apparent pH of point of zero charge of similar to 7.7, consistent with a positively charged surface at pH ≤ 7.7. These differences are shown to stem from proton consumption by both proton exchange and dissolution reactions at the FAP surface. After taking account for these effects, FAP surface charge is shown to be negative to at least pH 4 by surface titration analysis. (authors)

  1. Spectroscopic and probe measurements of the electron temperature in the plasma of a pulse-periodic microwave discharge in argon

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V., E-mail: vvandreev@mail.ru; Vasileska, I., E-mail: ivonavasileska@yahoo.com; Korneeva, M. A., E-mail: korneevama@mail.ru [Peoples’ Friendship University of Russia (Russian Federation)

    2016-07-15

    A pulse-periodic 2.45-GHz electron-cyclotron resonance plasma source on the basis of a permanent- magnet mirror trap has been constructed and tested. Variations in the discharge parameters and the electron temperature of argon plasma have been investigated in the argon pressure range of 1 × 10{sup –4} to 4 × 10{sup –3} Torr at a net pulsed input microwave power of up to 600 W. The plasma electron temperature in the above ranges of gas pressures and input powers has been measured by a Langmuir probe and determined using optical emission spectroscopy (OES) from the intensity ratios of spectral lines. The OES results agree qualitatively and quantitatively with the data obtained using the double probe.

  2. Mass spectroscopic measurements in the plasma edge of the W7-AS stellarator and their statistical analysis

    International Nuclear Information System (INIS)

    Zebisch, P.; Grigull, P.; Dose, V.; Taglauer, E.

    1997-01-01

    During the W7-AS operation period in autumn 1995 sniffer probe measurements were made for more than 800 discharges. The H/D ratio during deuterium discharges was determined showing HD and H 2 desorption from the walls even after fresh boronization. For these discharges the loading of the walls with deuterium could be observed. In the higher mass range the development of large amounts of hydrocarbons was observed at the beginning of the discharges with neutral beam injection. To evaluate the large amount of data recorded here (order of 10000 mass spectra), appropriate mathematical methods are required. It is shown that group analysis can be applied to distinguish certain sets of discharges and to derive useful mean values. (orig.)

  3. Laser-induced carbon plasma emission spectroscopic measurements on solid targets and in gas-phase optical breakdown

    International Nuclear Information System (INIS)

    Nemes, Laszlo; Keszler, Anna M.; Hornkohl, James O.; Parigger, Christian

    2005-01-01

    We report measurements of time- and spatially averaged spontaneous-emission spectra following laser-induced breakdown on a solid graphite/ambient gas interface and on solid graphite in vacuum, and also emission spectra from gas-phase optical breakdown in allene C3H4 and helium, and in CO2 and helium mixtures. These emission spectra were dominated by CII (singly ionized carbon), CIII (doubly ionized carbon), hydrogen Balmer beta (H b eta), and Swan C2 band features. Using the local thermodynamic equilibrium and thin plasma assumptions, we derived electron number density and electron temperature estimates. The former was in the 1016 cm -3 range, while the latter was found to be near 20000 K. In addition, the vibration-rotation temperature of the Swan bands of the C2 radical was determined to be between 4500 and 7000 K, using an exact theoretical model for simulating diatomic emission spectra. This temperature range is probably caused by the spatial inhomogeneity of the laser-induced plasma plume. Differences are pointed out in the role of ambient CO2 in a solid graphite target and in gas-phase breakdown plasma

  4. Spectroscopic methods for aqueous cyclodextrin inclusion complex binding measurement for 1,4-dioxane, chlorinated co-contaminants, and ozone

    Science.gov (United States)

    Khan, Naima A.; Johnson, Michael D.; Carroll, Kenneth C.

    2018-03-01

    Recalcitrant organic contaminants, such as 1,4-dioxane, typically require advanced oxidation process (AOP) oxidants, such as ozone (O3), for their complete mineralization during water treatment. Unfortunately, the use of AOPs can be limited by these oxidants' relatively high reactivities and short half-lives. These drawbacks can be minimized by partial encapsulation of the oxidants within a cyclodextrin cavity to form inclusion complexes. We determined the inclusion complexes of O3 and three common co-contaminants (trichloroethene, 1,1,1-trichloroethane, and 1,4-dioxane) as guest compounds within hydroxypropyl-β-cyclodextrin. Both direct (ultraviolet or UV) and competitive (fluorescence changes with 6-p-toluidine-2-naphthalenesulfonic acid as the probe) methods were used, which gave comparable results for the inclusion constants of these species. Impacts of changing pH and NaCl concentrations were also assessed. Binding constants increased with pH and with ionic strength, which was attributed to variations in guest compound solubility. The results illustrate the versatility of cyclodextrins for inclusion complexation with various types of compounds, binding measurement methods are applicable to a wide range of applications, and have implications for both extraction of contaminants and delivery of reagents for treatment of contaminants in wastewater or contaminated groundwater.

  5. The Thirty Gigahertz Instrument Receiver for the QUIJOTE Experiment: Preliminary Polarization Measurements and Systematic-Error Analysis

    Directory of Open Access Journals (Sweden)

    Francisco J. Casas

    2015-08-01

    Full Text Available This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process.

  6. Broadband time-resolved elliptical crystal spectrometer for X-ray spectroscopic measurements in laser-produced plasmas

    International Nuclear Information System (INIS)

    Wang Rui-Rong; Jia Guo; Fang Zhi-Heng; Wang Wei; Meng Xiang-Fu; Xie Zhi-Yong; Zhang Fan

    2014-01-01

    The X-ray spectrometer used in high-energy-density plasma experiments generally requires both broad X-ray energy coverage and high temporal, spatial, and spectral resolutions for overcoming the difficulties imposed by the X-ray background, debris, and mechanical shocks. By using an elliptical crystal together with a streak camera, we resolve this issue at the SG-II laser facility. The carefully designed elliptical crystal has a broad spectral coverage with high resolution, strong rejection of the diffuse and/or fluorescent background radiation, and negligible source broadening for extended sources. The spectra that are Bragg reflected (23° < θ < 38°) from the crystal are focused onto a streak camera slit 18 mm long and about 80 μm wide, to obtain a time-resolved spectrum. With experimental measurements, we demonstrate that the quartz(1011) elliptical analyzer at the SG-II laser facility has a single-shot spectral range of (4.64–6.45) keV, a typical spectral resolution of E/ΔE = 560, and an enhanced focusing power in the spectral dimension. For titanium (Ti) data, the lines of interest show a distribution as a function of time and the temporal variations of the He-α and Li-like Ti satellite lines and their spatial profiles show intensity peak red shifts. The spectrometer sensitivity is illustrated with a temporal resolution of better than 25 ps, which satisfies the near-term requirements of high-energy-density physics experiments. (atomic and molecular physics)

  7. Mid-infrared spectroscopic investigation

    International Nuclear Information System (INIS)

    Walter, L.; Vergo, N.; Salisbury, J.W.

    1987-01-01

    Mid-infrared spectroscopic research efforts are discussed. The development of a new instrumentation to permit advanced measurements in the mid-infrared region of the spectrum, the development of a special library of well-characterized mineral and rock specimens for interpretation of remote sensing data, and cooperative measurements of the spectral signatures of analogues of materials that may be present on the surfaces of asteroids, planets or their Moons are discussed

  8. The absorption spectrum of water vapor in the 2.2 μm transparency window: High sensitivity measurements and spectroscopic database

    International Nuclear Information System (INIS)

    Campargue, A.; Mikhailenko, S.N.; Vasilchenko, S.; Reynaud, C.; Béguier, S.; Čermák, P.; Mondelain, D.; Kassi, S.; Romanini, D.

    2017-01-01

    The weak absorption spectrum of water vapor in the important 2.2 μm transparency window is investigated with very high sensitivity. Overall, about 400 absorption lines were measured by Cavity Ring Down Spectroscopy (CRDS) and Optical-Feedback-Cavity Enhanced Laser Spectroscopy (OF-CEAS) in five spectral intervals: 4248.2–4257.3, 4298.4–4302.6, 4336.8.5-4367.5, 4422.4-4441.2 and 4514.6-4533.7 cm"−"1. The achieved sensitivity of the recordings (noise equivalent absorption, α_m_i_n, on the order of 2×10"−"1"0 cm"−"1) allowed detecting transitions with intensity values down to 1×10"−"2"8 cm/molecule, more than one order of magnitude better than previous studies by Fourier Transform spectroscopy. The rovibrational assignment was performed on the basis of variational calculations and of previously determined empirical energy values. Most of the newly assigned lines correspond to transitions of the ν_1, ν_3 and 3ν_2 bands of H_2"1"7O in natural isotopic abundance. Fourteen energy levels of H_2"1"7O, H_2"1"8O and HD"1"8O are newly determined. An accurate and complete spectroscopic database is constructed for natural water in the 4190–4550 cm"−"1 region (2.39–2.20 µm). The list includes about 4500 transitions with intensity greater than 1×10"−"2"9 cm/molecule, for the six most abundant isotopologues in natural isotopic abundance. Line positions were obtained by difference of empirical energy values determined from literature data and complemented with the present CRDS results. The list is made mostly complete by including weak transitions not yet detected, with positions calculated from empirical levels and variational intensities. The variational intensities computed by a collaboration between the University College London and the Institute of Applied Physics in Nizhny Novgorod are found to improve significantly previous results by Schwenke and Partridge. Examples of comparison of the constructed line list to CRDS spectra and to simulations

  9. Multi-pass spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Stehle, Jean-Louis; Samartzis, Peter C.; Stamataki, Katerina; Piel, Jean-Philippe; Katsoprinakis, George E.; Papadakis, Vassilis; Schimowski, Xavier; Rakitzis, T. Peter; Loppinet, Benoit

    2014-01-01

    Spectroscopic ellipsometry is an established technique, particularly useful for thickness measurements of thin films. It measures polarization rotation after a single reflection of a beam of light on the measured substrate at a given incidence angle. In this paper, we report the development of multi-pass spectroscopic ellipsometry where the light beam reflects multiple times on the sample. We have investigated both theoretically and experimentally the effect of sample reflectivity, number of reflections (passes), angles of incidence and detector dynamic range on ellipsometric observables tanΨ and cosΔ. The multiple pass approach provides increased sensitivity to small changes in Ψ and Δ, opening the way for single measurement determination of optical thickness T, refractive index n and absorption coefficient k of thin films, a significant improvement over the existing techniques. Based on our results, we discuss the strengths, the weaknesses and possible applications of this technique. - Highlights: • We present multi-pass spectroscopic ellipsometry (MPSE), a multi-pass approach to ellipsometry. • Different detectors, samples, angles of incidence and number of passes were tested. • N passes improve polarization ratio sensitivity to the power of N. • N reflections improve phase shift sensitivity by a factor of N. • MPSE can significantly improve thickness measurements in thin films

  10. Measurements of entanglement over a kilometric distance to test superluminal models of Quantum Mechanics: preliminary results.

    Science.gov (United States)

    Cocciaro, B.; Faetti, S.; Fronzoni, L.

    2017-08-01

    As shown in the EPR paper (Einstein, Podolsky e Rosen, 1935), Quantum Mechanics is a non-local Theory. The Bell theorem and the successive experiments ruled out the possibility of explaining quantum correlations using only local hidden variables models. Some authors suggested that quantum correlations could be due to superluminal communications that propagate isotropically with velocity vt > c in a preferred reference frame. For finite values of vt and in some special cases, Quantum Mechanics and superluminal models lead to different predictions. So far, no deviations from the predictions of Quantum Mechanics have been detected and only lower bounds for the superluminal velocities vt have been established. Here we describe a new experiment that increases the maximum detectable superluminal velocities and we give some preliminary results.

  11. Velocity Measurements in Nasal Cavities by Means of Stereoscopic Piv - Preliminary Tests

    Science.gov (United States)

    Cozzi, Fabio; Felisati, Giovanni; Quadrio, Maurizio

    2017-08-01

    The prediction of detailed flow patterns in human nasal cavities using computational fluid dynamics (CFD) can provide essential information on the potential relationship between patient-specific geometrical characteristics of the nasal anatomy and health problems, and ultimately led to improved surgery. The complex flow structure and the intricate geometry of the nasal cavities make achieving such goals a challenge for CFD specialists. The need for experimental data to validate and improve the numerical simulations is particularly crucial. To this aim an experimental set-up based on Stereo PIV and a silicon phantom of nasal cavities have been designed and realized at Politecnico di Milano. This work describes the main features and challenges of the set-up along with some preliminary results.

  12. Effect of gamma radiation on the spectroscopic properties of Bromocresol green-polyvinyl chloride film

    International Nuclear Information System (INIS)

    Bera, Anuradha; Ram, Surendra; Singh, Shailendra K.; Vaijapurkar, S.G.

    2009-01-01

    Bromocresol Green (BCG) - Polyvinyl chloride (PVC) film was prepared by dispersing the dye in the polymer matrix in a suitable solvent medium in the presence of an organic base and then solvent casting the formulation in the form of transparent colored film. Preliminary studies through UV-Vis Spectroscopic measurements show that the prepared PVC - dye films was sensitive to gamma radiation almost linearly in the dose range upto 8 kGy range. This spectroscopic change becomes visually distinguishable from 4 kGy onwards until 8 kGy where it finally changes color from green to yellow, beyond which no significant optical change was observed. The gamma response of the film could be tailored by varying the concentration of the pH sensitive dye and the organic base. (author)

  13. Plasma flow velocity measurements using a modulated Michelson interferometer

    NARCIS (Netherlands)

    Howard, J.; Meijer, F. G.

    1997-01-01

    This paper discusses the possibility of flow velocity reconstruction using passive spectroscopic techniques. We report some preliminary measurements of the toroidal flow velocity of hydrogen atoms in the RTP tokamak using a phase modulated Michelson interferometer. (C) 1997 Elsevier Science S.A.

  14. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  15. Development of an X-ray installation for the study of secondary electrons: preliminary measurements and calculations

    International Nuclear Information System (INIS)

    Baguena, A.; Shaw, M.; Williart, A.; Baguena, A.; Garcia, G.

    2006-01-01

    We describe the calculations and preliminary measures made for the installation of a X-ray generator tube. This device is going to be used for the secondary electron production from photonic primary radiation of up to 125 keV. With this experimental system, we will study the energetic and space distribution of produced secondary electrons by obtaining its spectrum of energies and its angular distribution. This method of measurement is going to be applied in different targets of radiological, environmental and biological interest. Calculations in the present article include: theoretical yield of X-rays production of the designed equipment, necessary shielding for the radiological safety of the installation staff, and an estimated dose due to their use. Characteristics of the installation and the equipment are described with this purpose. (author)

  16. Preparation of 3-7 MeV neutron source and preliminary results of activation cross section measurement

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, T.; Masuda, T.; Tsurita, Y.; Hashimoto, A.; Miyajima, N. [Department of Nuclear Engineering, Nagoya University, Nagoya, Aichi (Japan); Sakane, H.; Shibata, M.; Yamamoto, H.; Kawade, K.

    1999-03-01

    A d-D gas target producing monoenergetic neutrons has been constructed for measurement of activation cross sections in the energy region of 3 to 7 MeV at Van de Graaff accelerator of Nagoya University. Neutron spectra and neutron fluxes were measured as a function of the incident deuteron energy. Preliminary results of activation cross sections were obtained for reactions {sup 27}Al(n, p){sup 27}Mg, {sup 27}Al(n, {alpha}){sup 24}Na, {sup 47}Ti(n, p){sup 47}Sc, {sup 56}Fe(n, p){sup 56}Mn, {sup 58}Ni(n, p){sup 58}Co and {sup 64}Zn(n, p){sup 64}Cu. The results are compared with the evaluated values of JENDL-3.2. A well-type HPGe detector was used for highly efficient detection. (author)

  17. Development of an X-ray installation for the study of secondary electrons: preliminary measurements and calculations

    Energy Technology Data Exchange (ETDEWEB)

    Baguena, A.; Shaw, M.; Williart, A. [Universidad Nacional de Educacion a Distancia, Dpto. Fisica de los Materiales, Madrid (Spain); Baguena, A. [Consejo de Seguridad Nuclear, Madrid (Spain); Garcia, G. [Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Madrid (Spain)

    2006-07-01

    We describe the calculations and preliminary measures made for the installation of a X-ray generator tube. This device is going to be used for the secondary electron production from photonic primary radiation of up to 125 keV. With this experimental system, we will study the energetic and space distribution of produced secondary electrons by obtaining its spectrum of energies and its angular distribution. This method of measurement is going to be applied in different targets of radiological, environmental and biological interest. Calculations in the present article include: theoretical yield of X-rays production of the designed equipment, necessary shielding for the radiological safety of the installation staff, and an estimated dose due to their use. Characteristics of the installation and the equipment are described with this purpose. (author)

  18. Structure and reactivity of lithium amides. /sup 6/Li, /sup 13/C, and /sup 15/N NMR spectroscopic studies and colligative measurements of lithium diphenylamide and lithium diphenylamide-lithium bromide complex solvated by tetrahydrofuran

    Energy Technology Data Exchange (ETDEWEB)

    DePue, J.S.; Collum, D.B.

    1988-08-03

    /sup 6/Li, /sup 13/C, and /sup 15/N NMR spectroscopic studies of lithium diphenylamide in THF/hydrocarbon solutions (THF = tetrahydrofuran) detected two different species. /sup 6/Li and /sup 15/N NMR spectroscopic studies of (/sup 6/Li, /sup 15/N)lithium diphenylamide showed the species observed at low THF concentrations to be a cyclic oligomer. Structural analogies provided strong support for a dimer while colligative measurements at 0/degrees/C indicated the dimer to be di- or trisolvated. On the basis of the observed mass action effects, the species appearing at intermediate THF concentrations is assigned as a contact or solvent-separated ion-paired monomer. Lithium diphenylamide forms a 1:1 adduct with lithium bromide at low THF concentrations. A combination of /sup 6/Li-/sup 15/N double labeling studies and colligative measurements supports a trisolvated cyclic mixed dimer structure. Although detailed spectroscopic studies at elevated THF concentrations were precluded by high fluctionality, the similarity of the /sup 13/C chemical shifts of lithium diphenylamide in the presence and absence of lithium bromide provide indirect evidence that the mixed dimer undergoes a THF concentration dependent dissociation to the monomeric amide and free lithium bromide. 24 references, 9 figures, 2 tables.

  19. FTIR-spectroscopic measurements of beryls of various sources and the geological mineralogical and gemmological characterization of diamonds of the Espinhago-range (Minas Gerais, Brazil)

    International Nuclear Information System (INIS)

    Banko, A. G.

    1997-09-01

    In this work international material of beryl was analyzed by FTIR-spectroscopy, electron microprobe, analytical scanning microscopy, moisture evolution analyzer and fluorine sensitive electrode. The FTIR-spectroscopic measurements and the determination of analytical water content reveal a logarithmic correlation between the beryl water content and the intensity of the H 2 O-combination band at 5275 cm -1 , using unpolarized IR-light. In addition, the intensities of the 3990 - 3970 cm -1 ,-, 3234 cm -1 and 3345 cm -1 -bands, measured with polarized IR-light parallel to the c-axis, are linearly correlated to the content of the alkali metals. Probably these bands correspond to fundamental (1st overtone of H 2 O-II/3234 cm -1 - and 3345 cm -1 ) and combination (alkaliO-H...OH 2 -II/ 3990 - 3970 cm -1 ) modes of bending vibrations. Beryl was deuterated at various temperature. No absorption were detected in the region at around 2390 cm -1 , 2470 cm -1 and 2940 cm -1 , which would prove an assignment related to the present of hydrogen. If alkali-hydroxide grouping in beryl-channel-positions is indeuterable, the model of fundamental and combination modes seems to be valid. The band at 3990 - 3970 cm -1 can also be assigned to the combination mode of alkali-oxygen (alkali (6),(12) -O-bonds) vibrations and the normal modes of the H 2 O- II -molecule. The three integral absorption coefficients - α 5267 (H 2 O-II)t α 5275 (H 2 O-I) and α 2358 (CO 2 ) - were used to subdivide the beryls into groups. The Espinhago-Diamond-Province reflects an interesting geologic history from Precambrian placer- to recent alluvial deposits. Mineralogical and gemmological features, in combination with geological aspects reflect the many reworking processes which affected Espinhago diamonds in time and space: the characteristics of diamond populations in their specific geologic environment represent the natural selection, which eliminated stones of low quality during geologic history. (author)

  20. Preliminary results on the implantation of a laboratory for the measurement of natural radiocarbon

    International Nuclear Information System (INIS)

    Pessenda, C.L.R.; Pessenda, R.; Nascimento Filho, V.F. do; Victoria, R.L.; Matsui, E.

    1990-01-01

    Though the project 'Amazonia I', activity 'Paleoclimatology', sub-project 'hydrologic cycle', the Centro de Energia Nuclear da Agricultura (CENA) from Universidade de Sao Paulo has received recently, from Atomic Energy International Agency a research apparatus for the tranformation of carbon from benzene samples and a liquid scintillator spectrometer of low background, for the detection of natural radiocarbon. In the production of 3ml of benzene, synthetized from oxalic acid P.A. and calcium carbonate P.A., it was obtained a performance of more than 80%; preliminary results were also obtained for shell and coal samples. For the detection of radiocarbon, after optimization of the spectral region, and selection of samples, it was seen that the efficiency of the spectrometer was of the order of 55%, with a base counting rate of 1,3 cmp. The age limit, under the actual operation conditions was 41.600 years 95% (2σ) and 36.700 years for 99% (3σ) considering a time counting of 1000 minutes for the sample and the bacground radiation. (A.C.A.S.) [pt

  1. Measuring attitudes towards suicide: Preliminary evaluation of an attitude towards suicide scale.

    Science.gov (United States)

    Cwik, Jan Christopher; Till, Benedikt; Bieda, Angela; Blackwell, Simon E; Walter, Carolin; Teismann, Tobias

    2017-01-01

    Our study aimed to validate a previously published scale assessing attitudes towards suicide. Factor structure, convergent and discriminant validity, and predictive validity were investigated. Adult German participants (N=503; mean age=24.74years; age range=18-67years) anonymously completed a set of questionnaires. An exploratory factor analysis was conducted, and incongruous items were deleted. Subsequently, scale properties of the reduced scale and its construct validity were analyzed. A confirmatory factor analysis was then conducted in an independent sample (N=266; mean age=28.77years; age range=18-88years) to further confirm the factor structure of the questionnaire. Parallel analysis indicated a three-factor solution, which was also supported by confirmatory factor analysis: right to commit suicide, interpersonal gesture and resilience. The subscales demonstrated acceptable construct and discriminant validity. Cronbach's α for the subscales ranged from 0.67 to 0.83, explaining 49.70% of the total variance. Positive attitudes towards suicide proved to be predictive of suicide risk status, providing preliminary evidence for the utility of the scale. Future studies aiming to reproduce the factor structure in a more heterogeneous sample are warranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. The 6 April 2009 earthquake at L'Aquila: a preliminary analysis of magnetic field measurements

    Directory of Open Access Journals (Sweden)

    U. Villante

    2010-02-01

    Full Text Available Several investigations reported the possible identification of anomalous geomagnetic field signals prior to earthquake occurrence. In the ULF frequency range, candidates for precursory signatures have been proposed in the increase in the noise background and polarization parameter (i.e. the ratio between the amplitude/power of the vertical component and that one of the horizontal component, in the changing characteristics of the slope of the power spectrum and fractal dimension, in the possible occurrence of short duration pulses. We conducted, with conventional techniques of data processing, a preliminary analysis of the magnetic field observations performed at L'Aquila during three months preceding the 6 April 2009 earthquake, focusing attention on the possible occurrence of features similar to those identified in previous events. Within the limits of this analysis, we do not find compelling evidence for any of the features which have been proposed as earthquake precursors: indeed, most of aspects of our observations (which, in some cases, appear consistent with previous findings might be interpreted in terms of the general magnetospheric conditions and/or of different sources.

  3. Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2015-08-01

    Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that manipulates the small fracture fragments through small percutaneous incisions and a robot that re-aligns the long bones. The robots controller design relies on accurate and bounded force and position parameters for which we require real surgical data. This paper reports preliminary findings of forces and torques applied during bone and soft tissue manipulation in typical orthopaedic surgery procedures. Using customised orthopaedic surgical tools we have collected data from a range of orthopaedic surgical procedures at Bristol Royal Infirmary, UK. Maximum forces and torques encountered during fracture manipulation which involved proximal femur and soft tissue distraction around it and reduction of neck of femur fractures have been recorded and further analysed in conjunction with accompanying image recordings. Using this data we are establishing a set of technical requirements for creating safe and dynamically stable minimally invasive robot-assisted fracture surgery (RAFS) systems.

  4. 1995 Integrated Monitoring Study: Fog measurements in the Southern San Joaquin Valley - preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Collett, J. Jr.; Bator, A.; Sherman, D.E. [Colorado State Univ., Fort Collins, CO (United States)] [and others

    1996-12-31

    Fogs were sampled at three ground-based stations in the southern portion of California`s San Joaquin Valley as part of the winter component of the 1995 Integrated Monitoring Study (IMS95). The three sampling sites included two urban locations (Bakersfield and Fresno) and one rural location (near the Kern Wildlife Refuge). Both bulk and drop size-fractionated samples were collected at each site. Several fog events were sampled, with three periods of extensive fog coverage that included all three sampling sites. Results of preliminary data analysis are presented. Fog collected at the sites was generally quite basic. Most bulk fog samples had pH values above 6 reflecting strong inputs from ammonia. Occasional strong sulfur plumes at Bakersfield, however, tended to lower the fog pH. Aside from these periods, nitrate was generally present at much higher concentrations in the fog than sulfate. Decreases in fogwater loadings of major species over the course of one extended fog episode at Fresno suggest significant deposition was occurring to the surface, consistent with observations of substantial droplet fluxes to exposed surfaces during that period. 16 refs., 7 figs., 1 tab.

  5. Impulsivity in Multiplayer Online Battle Arena Gamers: Preliminary Results on Experimental and Self-Report Measures.

    Science.gov (United States)

    Nuyens, Filip; Deleuze, Jory; Maurage, Pierre; Griffiths, Mark D; Kuss, Daria J; Billieux, Joël

    2016-06-01

    Background and aims Multiplayer Online Battle Arena (MOBA) games have become the most popular type of video games played worldwide, superseding the playing of Massively Multiplayer Online Role-Playing Games and First-Person Shooter games. However, empirical studies focusing on the use and abuse of MOBA games are still very limited, particularly regarding impulsivity, which is an indicator of addictive states but has not yet been explored in MOBA games. In this context, the objective of the present study is to explore the associations between impulsivity and symptoms of addictive use of MOBA games in a sample of highly involved League of Legends (LoL, currently the most popular MOBA game) gamers. Methods Thirty-six LoL gamers were recruited and completed both experimental (Single Key Impulsivity Paradigm) and self-reported impulsivity assessments (s-UPPS-P Impulsive Behavior Scale, Barratt Impulsiveness Scale), in addition to an assessment of problematic video game use (Problematic Online Gaming Questionnaire). Results Results showed links between impulsivity-related constructs and signs of excessive MOBA game involvement. Findings indicated that impaired ability to postpone rewards in an experimental laboratory task was strongly related to problematic patterns of MOBA game involvement. Although less consistent, several associations were also found between self-reported impulsivity traits and signs of excessive MOBA game involvement. Conclusions Despite these results are preliminary and based upon a small (self-selected) sample, the present study highlights potential psychological factors related to the addictive use of MOBA games.

  6. Impulsivity in Multiplayer Online Battle Arena Gamers: Preliminary Results on Experimental and Self-Report Measures

    Science.gov (United States)

    Nuyens, Filip; Deleuze, Jory; Maurage, Pierre; Griffiths, Mark D.; Kuss, Daria J.; Billieux, Joël

    2016-01-01

    Background and aims Multiplayer Online Battle Arena (MOBA) games have become the most popular type of video games played worldwide, superseding the playing of Massively Multiplayer Online Role-Playing Games and First-Person Shooter games. However, empirical studies focusing on the use and abuse of MOBA games are still very limited, particularly regarding impulsivity, which is an indicator of addictive states but has not yet been explored in MOBA games. In this context, the objective of the present study is to explore the associations between impulsivity and symptoms of addictive use of MOBA games in a sample of highly involved League of Legends (LoL, currently the most popular MOBA game) gamers. Methods Thirty-six LoL gamers were recruited and completed both experimental (Single Key Impulsivity Paradigm) and self-reported impulsivity assessments (s-UPPS-P Impulsive Behavior Scale, Barratt Impulsiveness Scale), in addition to an assessment of problematic video game use (Problematic Online Gaming Questionnaire). Results Results showed links between impulsivity-related constructs and signs of excessive MOBA game involvement. Findings indicated that impaired ability to postpone rewards in an experimental laboratory task was strongly related to problematic patterns of MOBA game involvement. Although less consistent, several associations were also found between self-reported impulsivity traits and signs of excessive MOBA game involvement. Conclusions Despite these results are preliminary and based upon a small (self-selected) sample, the present study highlights potential psychological factors related to the addictive use of MOBA games. PMID:27156376

  7. Feasibility, safety, acceptability, and preliminary efficacy of measurement-based care depression treatment for HIV patients in Bamenda, Cameroon.

    Science.gov (United States)

    Pence, Brian W; Gaynes, Bradley N; Atashili, Julius; O'Donnell, Julie K; Kats, Dmitry; Whetten, Kathryn; Njamnshi, Alfred K; Mbu, Tabenyang; Kefie, Charles; Asanji, Shantal; Ndumbe, Peter

    2014-06-01

    Depression affects 18-30 % of HIV-infected patients in Africa and is associated with greater stigma, lower antiretroviral adherence, and faster disease progression. However, the region's health system capacity to effectively identify and treat depression is limited. Task-shifting models may help address this large mental health treatment gap. Measurement-Based Care (MBC) is a task-shifting model in which a Depression Care Manager guides a non-psychiatric (e.g., HIV) provider in prescribing and managing antidepressant treatment. We adapted MBC for depressed HIV-infected patients in Cameroon and completed a pilot study to assess feasibility, safety, acceptability, and preliminary efficacy. We enrolled 55 participants; all started amitriptyline 25-50 mg daily at baseline. By 12 weeks, most remained at 50 mg daily (range 25-125 mg). Median (interquartile range) PHQ-9 depressive severity scores declined from 13 (12-16) (baseline) to 2 (0-3) (week 12); 87 % achieved depression remission (PHQ-9 feasibility, safety, acceptability, and preliminary efficacy in this uncontrolled pilot study. Further research should assess whether MBC could improve adherence and HIV outcomes in this setting.

  8. Preliminary analysis of osteocyte lacunar density in long bones of tetrapods: all measures are bigger in sauropod dinosaurs.

    Science.gov (United States)

    Stein, Koen W H; Werner, Jan

    2013-01-01

    Osteocytes harbour much potential for paleobiological studies. Synchrotron radiation and spectroscopic analyses are providing fascinating data on osteocyte density, size and orientation in fossil taxa. However, such studies may be costly and time consuming. Here we describe an uncomplicated and inexpensive method to measure osteocyte lacunar densities in bone thin sections. We report on cell lacunar densities in the long bones of various extant and extinct tetrapods, with a focus on sauropodomorph dinosaurs, and how lacunar densities can help us understand bone formation rates in the iconic sauropod dinosaurs. Ordinary least square and phylogenetic generalized least square regressions suggest that sauropodomorphs have lacunar densities higher than scaled up or comparably sized mammals. We also found normal mammalian-like osteocyte densities for the extinct bovid Myotragus, questioning its crocodilian-like physiology. When accounting for body mass effects and phylogeny, growth rates are a main factor determining the density of the lacunocanalicular network. However, functional aspects most likely play an important role as well. Observed differences in cell strategies between mammals and dinosaurs likely illustrate the convergent nature of fast growing bone tissues in these groups.

  9. Preliminary analysis of osteocyte lacunar density in long bones of tetrapods: all measures are bigger in sauropod dinosaurs.

    Directory of Open Access Journals (Sweden)

    Koen W H Stein

    Full Text Available Osteocytes harbour much potential for paleobiological studies. Synchrotron radiation and spectroscopic analyses are providing fascinating data on osteocyte density, size and orientation in fossil taxa. However, such studies may be costly and time consuming. Here we describe an uncomplicated and inexpensive method to measure osteocyte lacunar densities in bone thin sections. We report on cell lacunar densities in the long bones of various extant and extinct tetrapods, with a focus on sauropodomorph dinosaurs, and how lacunar densities can help us understand bone formation rates in the iconic sauropod dinosaurs. Ordinary least square and phylogenetic generalized least square regressions suggest that sauropodomorphs have lacunar densities higher than scaled up or comparably sized mammals. We also found normal mammalian-like osteocyte densities for the extinct bovid Myotragus, questioning its crocodilian-like physiology. When accounting for body mass effects and phylogeny, growth rates are a main factor determining the density of the lacunocanalicular network. However, functional aspects most likely play an important role as well. Observed differences in cell strategies between mammals and dinosaurs likely illustrate the convergent nature of fast growing bone tissues in these groups.

  10. Development and preliminary testing of the Schizophrenia Hope Scale, a brief scale to measure hope in people with schizophrenia.

    Science.gov (United States)

    Choe, Kwisoon

    2014-06-01

    Hope has received attention as a central component of recovery from mental illness; however, most instruments measuring hope were developed outside the mental health field. To measure the effects of mental health programs on hope in people with schizophrenia, a specialized scale is needed. This study examined the psychometric properties of the newly developed 9-item Schizophrenia Hope Scale (SHS-9) designed to measure hope in individuals with schizophrenia. A descriptive survey design. Participants were recruited from three psychiatric hospitals and two community mental health centers in South Korea. A total of 347 individuals over age 18 with a DSM-IV diagnosis of schizophrenia, schizoaffective, or schizophrenia spectrum disorders (competent to provide written informed consent) participated in this study; 149 (94 men, 55 women) completed a preliminary scale consisting of 40 revised items, and 198 (110 men, 88 women) completed the second scale of 17 items. Scale items were first selected from extensive literature reviews and a qualitative study on hope in people with schizophrenia; the validity and reliability of a preliminary scale was then evaluated by an expert panel and exploratory factor analysis. The remaining 9 items forming the Schizophrenia Hope Scale (SHS-9) were evaluated through confirmatory factor analysis. The SHS-9 demonstrates promising psychometric integrity. The internal consistency alpha coefficient was 0.92 with a score range of 0-18 and a mean total score of 12.06 (SD=4.96), with higher scores indicating higher levels of hope. Convergent validity was established by correlating the SHS-9 to the State-Trait Hope Inventory, r=0.61 (phope accounting for 61.77% of the total item variance. As hope has been shown to facilitate recovery from mental illness, the accurate assessment of hope provided by the short, easy-to-use Schizophrenia Hope Scale (SHS-9) may aid clinicians in improving the quality of life of individuals with schizophrenia. Copyright

  11. Conception and preliminary evaluation of an optical fibre sensor for simultaneous measurement of pressure and temperature

    International Nuclear Information System (INIS)

    Bremer, K; Moss, B; Leen, G; Mueller, I; Lewis, E; Lochmann, S

    2009-01-01

    This paper presents a novel concept of simultaneously measuring pressure and temperature using a silica optical fibre extrinsic Fabry-Perot interferometric (EFPI) pressure sensor incorporating a fibre Bragg grating (FBG), which is constructed entirely from fused-silica. The novel device is used to simultaneously provide accurate pressure and temperature readings at the point of measurement. Furthermore, the FBG temperature measurement is used to eliminate the temperature cross-sensitivity of the EFPI pressure sensor.

  12. REFLECTANCE ANISOTROPY MEASUREMENTS USING A PUSHBROOM SPECTROMETER MOUNTED ON UAV AND A LABORATORY GONIOMETER – PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    J. Suomalainen

    2015-08-01

    Full Text Available During 2014–2015 we have developed a new method to measure reflectance factor anisotropy using a pushbroom spectrometer mounted on a multicopter UAV. In this paper/presentation we describe the acquisition method and show the preliminary results of the experiment. To validate the measurements the same targets have also been measured with a laboratory goniometer system. The first experiments over sugar beet fields in 2014 show similar trends in both UAV and laboratory anisotropy data, but also some differences caused by differences in sampling and diffuse illumination. In 2015 a more extensive study on wheat, barley and potato fields were performed. The measurements were repeated on three days over the growth of the crops allowing linking the development of the crops to the anisotropy signals. On each day the anisotropy measurement was repeated 4–5 times with different solar zenith angles ranging from 60° to 40° allowing analysis how the solar angle affects the anisotropy. The first results of these experiments will be presented in this conference.

  13. Preliminary Analysis of Contamination Measurements from the ESEX 26 kW Ammonia Arcjet Flight Experiment

    National Research Council Canada - National Science Library

    Spanjers, G

    1999-01-01

    .... The sensors consisted of microbalances to measure material deposition, radiometers to assess material degradation due to thermal radiation, and solar cell segments to investigate solar array degradation...

  14. Preliminary study of temperature measurement techniques for Stirling engine reciprocating seals

    Science.gov (United States)

    Wilcock, D. F.; Hoogenboom, L.; Meinders, M.; Winer, W. O.

    1981-01-01

    Methods of determining the contact surface temperature in reciprocating seals are investigated. Direct infrared measurement of surface temperatures of a rod exiting a loaded cap seal or simulated seal are compared with surface thermocouple measurements. Significant cooling of the surface requires several milliseconds so that exit temperatures may be considered representative of internal contact temperatures.

  15. Measures of Hindu Pathways: Development and Preliminary Evidence of Reliability and Validity.

    Science.gov (United States)

    Tarakeshwar, Nalini; Pargament, Kenneth I.; Mahoney, Annette

    2003-01-01

    Examines religious practices of Hindus in the United States and develops measures of their religious pathways. Four religious pathways were identified: devotion, ethical action, knowledge, and physical restraint/yoga. Results indicate that the measures of the religious pathways possessed adequate psychometric properties and were predictive of…

  16. Preliminary results of radiometric measurements of clear air and cloud brightness (antenna) temperatures at 37GHz

    Science.gov (United States)

    Arakelyan, A. K.; Hambaryan, A. K.; Arakelyan, A. A.

    2012-05-01

    In this paper the results of polarization measurements of clear air and clouds brightness temperatures at 37GHz are presented. The results were obtained during the measurements carried out in Armenia from the measuring complex built under the framework of ISTC Projects A-872 and A-1524. The measurements were carried out at vertical and horizontal polarizations, under various angles of sensing by Ka-band combined scatterometric-radiometric system (ArtAr-37) developed and built by ECOSERV Remote Observation Centre Co.Ltd. under the framework of the above Projects. In the paper structural and operational features of the utilized system and the whole measuring complex will be considered and discussed as well.

  17. Spectroscopic system for impurity measurements in the TJ-1 Tokamak of JEN; Un sistema espectroscopico para medidas de impurezas en el Tokamak TJ-1 de la JEN

    Energy Technology Data Exchange (ETDEWEB)

    Navas, G; Zurro, B

    1982-07-01

    we describe a spectroscopic system with spatial resolution capability that has been configured for plasma diagnostic in the TJ-1 Tokamak of JEN. The experimental system, based on a one meter monochromator, has been absolutely calibrated using a tungsten-halogen lamp. The calibration procedures and the absolute spectral sensitivity are presented as well as its dependence with the polarization. A simplified spectroscopic model of the radiation emitted by the intrinsic plasma impurities (C, 0, . . . ) has been developed. A one dimensional model of the temporal evolution of various ionization stages in coronal equilibrium is used to predict the electron temperature and impurity concentration. This model has been applied to experimental data from several Tokamaks. (Author) 23 refs.

  18. Development of a prototype for dissolved CO2 rapid measurement and preliminary tests

    Science.gov (United States)

    Li, Meng; Guo, Jinjia; Zhang, Zhihao; Luo, Zhao; Qin, Chuan; Zheng, Ronger

    2017-10-01

    The measurements of dissolved CO2 in seawater is of great significance for the study of global carbon cycle. At present, the commercial sensors used for dissolved CO2 measurements are mostly equipped with permeable membranes for the purpose of gas-liquid separation, with the advantages of easy operation, low cost, etc.. However, most of these devices measure CO2 after reaching gas equilibrium, so it takes a few minutes to respond, which limited its applications in rapid measurements. In this paper, a set of prototype was developed for the rapid measurements of dissolved CO2. The system was built basing the direct absorption TDLAS. To detect the CO2 absorption line located at 4991.26 cm-1 , a fiber-coupled DFB laser operating at 2004 nm was selected as the light source. A Herriott type multi-pass cavity with an effective optical path length of 10 m and an inner volume of 90 mL was used for absorption measurements. A detection limit of 26 μatm can be obtained with this compact cavity. To realize the rapid measurements of dissolved CO2, a degasser with high degassing rate was necessary. A hollow fiber membrane with a large permeable area used in this paper can achieve degassing rate up to 2.88 kPa/min. Benefitted from the high degassing rate of the degasser and high sensitivity of the compact TDLAS system, a rapid measurement of dissolved CO2 in water can be achieved within 1s time, and the response time of the prototype when the dissolved CO2 concentration changed abruptly in actual measurement was 15 s. To evaluate the performance of the prototype, comparison measurements were carried out with a commercial mass spectrometer. The dissolved CO2 in both seawater and tap-water was measured, and the experimental results showed good consistent trends with R2 of 0.973 and 0.931. The experimental results proved the feasibility of dissolved CO2 rapid measurement. In the near future, more system evaluation experiments will be carried out and the system will be further

  19. A new airborne Polar Nephelometer for the measurement of optical and microphysical cloud properties. Part II: Preliminary tests

    Directory of Open Access Journals (Sweden)

    O. Crépel

    Full Text Available A new optical sensor, the airborne Polar Nephelometer, has been tested in an open wind tunnel. The wind tunnel was operated in cloudy conditions including either cloud water droplets or ice crystals, or a mixture of these particles. The sensor is designed to measure the optical and microphysical parameters of cloud particles sized from a few micrometers to about 500 µm diameter. Basically, the probe measures the scattering phase function of an ensemble of cloud particles which intersect a collimated laser beam near the focal point of a paraboloidal mirror. From the measured scattering phase function the retrieval of the droplet-size spectra and subsequent derived quantities such as liquid water content and size parameters can be calculated using an inversion method. The particle phase discrimination (water droplets/ice particles can be derived from the shape of the scattering phase function and the sensitivity of the probe allows the detection of small ice crystals (typically of 5 µm diameter. The paper describes the preliminary results obtained by the prototype version of the Polar Nephelometer in various cloudy conditions. These results are compared with direct microphysical measurements obtained by usual PMS probes also mounted in the wind tunnel. Complementary results obtained in a cold chamber are presented in order to illustrate the reliability of the Polar Nephelometer in the presence of small ice crystals.

  20. Preliminary measurement performance evaluation of a new white light interferometer for cylindrical surfaces

    International Nuclear Information System (INIS)

    Albertazzi, Armando Jr; Pont, Alex Dal

    2005-01-01

    This paper introduces a new design of a white light interferometer, suitable for measurement of cylindrical or quasi-cylindrical parts. A high precision 45 deg. conical mirror is used to direct collimated light radially, making it possible to measure in true cylindrical coordinates. The image of the measurand, distorted by the conical mirror, is projected in a high resolution digital camera. A mapping algorithm is used to reconstruct the cylindrical geometry from the distorted image. The rest of the interferometer is quite similar to a conventional white light interferometer: A flat reference mirror is scanned through the measurement range while an algorithm is searching for the maximum contrast position of the interference pattern. The performance evaluation of a configuration suitable for measurement of external cylindrical surfaces is also presented in this paper. A master cylinder was used as reference. Uncertainties of about 1.0 μm were found at the present stage of development

  1. Spectral and Broad Band Ultraviolet Measurements in Valencia (Spain): A Preliminary Comparison

    International Nuclear Information System (INIS)

    Tena, F.; Marin, M.J.; Martinez-Lozano, J.A.; Utrillas, M.P.; Gomez, J.L.

    2000-01-01

    The Solar Radiation Group of the University of Valencia, in collaboration with the National Institute of Meteorology (INM), recently began a database of erythemal UV irradiance measurements. Such measurements are obtained by a YES UVB-1 pyranometer (280-330 nm) that measures continuously, integrates the values and stores them in a database. The measured values are being compared with those obtained by the integration of the data registered by an Optronic OL 754 spectroradiometer (250-800 nm) considering clear days and different solar zenith angles. For the present study only the data corresponding to the summer (1999) are being considered because these are the days of the year with the higher erythemal values and also the season when people enjoy sunbathing. The results are used to deduce the ultraviolet index (UVI) related to the erythemal doses and the sunburn time. (author)

  2. Spectral and Broad Band Ultraviolet Measurements in Valencia (Spain): A Preliminary Comparison

    Energy Technology Data Exchange (ETDEWEB)

    Tena, F.; Marin, M.J.; Martinez-Lozano, J.A.; Utrillas, M.P.; Gomez, J.L

    2000-07-01

    The Solar Radiation Group of the University of Valencia, in collaboration with the National Institute of Meteorology (INM), recently began a database of erythemal UV irradiance measurements. Such measurements are obtained by a YES UVB-1 pyranometer (280-330 nm) that measures continuously, integrates the values and stores them in a database. The measured values are being compared with those obtained by the integration of the data registered by an Optronic OL 754 spectroradiometer (250-800 nm) considering clear days and different solar zenith angles. For the present study only the data corresponding to the summer (1999) are being considered because these are the days of the year with the higher erythemal values and also the season when people enjoy sunbathing. The results are used to deduce the ultraviolet index (UVI) related to the erythemal doses and the sunburn time. (author)

  3. Preliminary report: Measurement of apixaban and rivaroxaban in plasma from bleeding patients

    DEFF Research Database (Denmark)

    Jensen, Kathrine Overgaard Foss; Hansen, Svend Høime; Gøtze, Jens Peter

    2017-01-01

    patients receiving rivaroxaban (n = 91) or apixaban (n = 15) showed agreement and correlation between the methods. Measurement in spiked plasma from patients with active bleeding, however, revealed a 26% overestimation by the assay. Conclusions Our findings show that Biophen is suitable for measuring...... apixaban and rivaroxaban concentrations in plasma. However, our results in patients with active bleeding show an overestimation of 26%. This should be taken into account when assessing possible intoxication with apixaban and rivaroxaban in patients presenting with bleeding....

  4. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  5. Preliminary measurements of the 87Rb half-life by means of the needle counter

    International Nuclear Information System (INIS)

    Zastawny, A.; Rabsztyn, B.

    1989-01-01

    In order to test the detector and to obtain the experience before starting the exact measurements, the measurements of 87 Rb half-life have been made. RbNO 3 produced by Merck was used to prepare the samples. The samples were prepared by evaporation of RbNO 3 water solution on an aluminium foil of 2,9 mg/cm 2 . The water solutions were changed in the range from (3286,4±1,8) x 10 -6 to (480,85±0,3) x 10 -6 . The background of the aluminium foil was equal to (0,117±0,007) cpm. In other measurements the back-scattering effect of 87 Rb beta rays on the aluminium foil amounted to 4%, as the measurements were performed in the 2π geometry. The diameters of samples were about 10 mm. The specific radioactivities of samples were measured versus the surface changed in the range (60-320) μg/cm 2 . The extrapolated value of the half-life, corrected for the chemical purity of the compound (as declared by the manufacterer) is equal to (4,86±0,1) x 10 10 years. This value is in good agreement with commonly accepted value of 4,88 x 10 10 years and with another last measurements. 10 refs., 1 fig., 2 tabs. (author)

  6. Air pulse deformation measurement: a preliminary method for noninvasive vocal fold pliability analysis.

    Science.gov (United States)

    Larsson, Hans; Lindestad, P Å; Hertegård, S

    2011-01-01

    A new method, air pulse pliability measurement, is presented, with which the pliability and elasticity of the vocal folds was measured in vitro and in vivo using air pulses. The size of the mucosal movements induced by air pulse stimulation was measured with a laser-based technique. The air pulses fed via a 2-mm tubing, introduced through the working channel of a flexible endoscope. Both in vitro and in vivo tests were performed. Nine normal, vocally healthy subjects were examined by air pulse stimulations of the vocal folds, of the skin (cheek and dorsum of the hand) and of the inside of the lips. The in vitro tests showed a coefficient of variation of 5% within a range of 1-5 mm from the probe to the surface. The elasticity data showed no differences between vocal folds, lips or cheek. The hand data showed a significantly higher stiffness as compared to the other 3 measuring points (p measuring points, but in ideal conditions on skin it was 9%. The results show that the technique allows automatic, quantitative, noninvasive vocal fold pliability measurements on awake subjects. Copyright © 2010 S. Karger AG, Basel.

  7. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion.

    Science.gov (United States)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao; Lu, Jun-Ying; Zeng, Yan-Hong; Meng, Fan-Jie; Cao, Bin; Zi, Xue-Rong; Han, Shu-Ming; Zhang, Yu-Huan

    2013-09-01

    Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 × d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l × h × d): V = 0.56 × (l × h × d) + 39.44 (r = 0.92, P = 0.000). The 64-slice CT volume-rendering technique can

  8. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    International Nuclear Information System (INIS)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao

    2013-01-01

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  9. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Zhi-Jun [Dept. of Radiology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)], e-mail: Gzj3@163.com; Lin, Qiang [Dept. of Oncology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China); Liu, Hai-Tao [Dept. of General Surgery, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)] [and others])

    2013-09-15

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  10. Preliminary results of measurements of air pollution caused by sulfur compounds near the Polaniec power plant

    Energy Technology Data Exchange (ETDEWEB)

    Dziewanski, J; Kasina, S; Lewinska, J; Piorek, S

    1976-01-01

    In the past investigations of the negative impact of power stations on the natural environment have been restricted to measuring sulfur dioxide content in the air. A method of determining complex influence of sulfur compounds on the natural environment is proposed. The following indexes are used: content of sulfur dioxide in the air, dust content (determined by means of the West-Gaeke method), content of sulphate ions in precipitation and pH value of precipitation. Methods used to determine each of the indexes are described. Location of measuring stations in the area where the power station is being constructed is evaluated, taking into account prevailing wind direction and atmospheric conditions (15 measuring points out of which 10 stations measure sulfur content in precipitation and pH value of precipitation, and 5 stations measure the mean daily concentration of sulfur dioxide and dust content). Results are presented in 3 maps, 1 table and 2 pictures. Variations in sulfur dioxide content, dust content, and pH value of precipitation depending on direction of wind, atmospheric conditions and season are analyzed. The results of the investigation will be compared with results of investigations carried out when the power station is in operation. (15 refs.)

  11. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Silver, N.C. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Barker, G.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Losseff, N.A. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Gawne-Cain, M.L. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); MacManus, D.G. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Thompson, A.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Miller, D.H. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom)

    1997-06-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P = 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab.

  12. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    International Nuclear Information System (INIS)

    Silver, N.C.; Barker, G.J.; Losseff, N.A.; Gawne-Cain, M.L.; MacManus, D.G.; Thompson, A.J.; Miller, D.H.

    1997-01-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab

  13. Preliminary study on the measurement of background radiation dose at Antarctica during 32nd expedition

    International Nuclear Information System (INIS)

    Bakshi, A.K.; Pal, Rupali; Chougaonkar, M.P.; Dhar, Ajay

    2013-01-01

    A significant proportion (10%) of the natural background radiation is of cosmic origin. Cosmic ray consists of gamma, protons, electrons, pions, muons, neutrons and low Z nuclei. Due to the geomagnetic effect, cosmic radiation levels at poles are higher. As a consequence, personnel working in Antarctica (or Arctic) are subjected to high level of cosmic radiation. The present study gives the details of the estimation of background radiation (neutrons, gamma and electrons) dose rate around the Indian station at Antarctica named 'Bharati' measured during 32 nd Indian scientific expedition to Antarctica (32 nd INSEA). The measurement was carried out by passive dosimeters such as TLDs and CR-39 and active dosimeter such as RadEye G portable gamma survey meter. Gamma and electron components were measured using TLDs and survey meter, whereas CR-39 SSNTDs and neutron sensitive TLDs were used for neutron measurements. These detectors were deployed at few selected locations around Bharati station for about 2½ months during summer expedition. The neutron detectors used in the study were pre-calibrated with 241 Am-Be fast/thermal neutron source. The fast neutron dose rate measured based on CR-39 detector was found to about 140-420 nSv/h. The gamma dose rate evaluated by TLDs/survey meter are in the range of 290-400 nSv/h. (author)

  14. A preliminary studyof the site-dependence of the multifractalfeatures of geoelectric measurements

    Directory of Open Access Journals (Sweden)

    M. Macchiato

    2004-06-01

    Full Text Available Multifractal analysis was performed to characterize the fluctuations in dynamics of the hourly time variability of self-potential signals measured from January 2001 to September 2002 by three stations installed in the Basilicata region (Southern Italy. Two stations (Giuliano and Tito are located in a seismic area, and one (Laterza in an aseismic area. Multifractal formalism leads to the identification of a set of parameters derived from the shape of the multifractal spectrum (the maximum a0, the asymmetry B and the width W and measuring the «complexity» of the signals. Furthermore, the multifractal parameters seem to discriminate self-potential signals measured in seismic areas from those recorded in aseismic areas.

  15. A novel mechatronic system for measuring end-point stiffness: mechanical design and preliminary tests.

    Science.gov (United States)

    Masia, L; Sandini, G; Morasso, P G

    2011-01-01

    Measuring arm stiffness is of great interest for many disciplines from biomechanics to medicine especially because modulation of impedance represents one of the main mechanism underlying control of movement and interaction with external environment. Previous works have proposed different methods to identify multijoint hand stiffness by using planar or even tridimensional haptic devices, but the associated computational burden makes them not easy to implement. We present a novel mechanism conceived for measuring multijoint planar stiffness by a single measurement and in a reduced execution time. A novel mechanical rotary device applies cyclic radial perturbation to human arm of a known displacement and the force is acquired by means of a 6-axes commercial load cell. The outcomes suggest that the system is not only reliable but allows obtaining a bi-dimensional estimation of arm stiffness in reduced amount of time and the results are comparable with those reported in previous researches. © 2011 IEEE

  16. Preliminary Measurement of Neutrino Oscillation Parameters By NuMI/MINOS and Calibration Studies for Improving this Measurement

    International Nuclear Information System (INIS)

    Symes, Philip Andrew; Sussex U.

    2005-01-01

    This thesis explains the origins of neutrinos and their interactions, and the phenomenon of neutrino oscillations. Experiments for measuring neutrino oscillations are mentioned and the experiment investigated in this thesis, the ''Main Injector Neutrino Oscillation Search'', and its neutrino beam, the Fermi National Accelerator Laboratory's ''Neutrinos At The Main Injector'', are described. MINOS is a long baseline (735 km) neutrino oscillation experiment with a near and a far detector, intended to make precision measurements of the atmospheric sector neutrino oscillation parameters. A measurement is made of the ''atmospheric'' neutrino oscillation parameters, Δm 23 2 and sin 2 (2θ 23 ), using neutrinos from the NuMI beam. The results of this analysis are compared to measurements at MINOS using neutrinos from the atmosphere and with other experiments. A more detailed method of beam neutrino analysis is discussed, and the extra calibrations needed to perform that analysis properly are described, with special attention paid to two aspects of the calibration, which comprise the bulk of work for this thesis. The light injection calibration system uses LEDs to illuminate the detector readout and provides a normalization of the stability of the detector over time. The hardware and different modi operandi of the system are described. There is a description of installation and commissioning of the system at one of the MINOS detectors. The response normalization of each detector with cosmic ray muons is described. Special attention is paid to the explanation of necessary corrections that must be made to the muon sample in order for the sample to be used to calibrate each detector to the specified accuracy. The performance of the calibration is shown

  17. Preliminary Measurement of Neutrino Oscillation Parameters By NuMI/MINOS and Calibration Studies for Improving this Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Symes, Philip Andrew [Univ. of Sussex, Brighton (United Kingdom)

    2005-11-01

    This thesis explains the origins of neutrinos and their interactions, and the phenomenon of neutrino oscillations. Experiments for measuring neutrino oscillations are mentioned and the experiment investigated in this thesis, the ''Main Injector Neutrino Oscillation Search'', and its neutrino beam, the Fermi National Accelerator Laboratory's ''Neutrinos At The Main Injector'', are described. MINOS is a long baseline (735 km) neutrino oscillation experiment with a near and a far detector, intended to make precision measurements of the atmospheric sector neutrino oscillation parameters. A measurement is made of the ''atmospheric'' neutrino oscillation parameters, Δm$2\\atop{23}$ and sin2(2θ23), using neutrinos from the NuMI beam. The results of this analysis are compared to measurements at MINOS using neutrinos from the atmosphere and with other experiments. A more detailed method of beam neutrino analysis is discussed, and the extra calibrations needed to perform that analysis properly are described, with special attention paid to two aspects of the calibration, which comprise the bulk of work for this thesis. The light injection calibration system uses LEDs to illuminate the detector readout and provides a normalization of the stability of the detector over time. The hardware and different modi operandi of the system are described. There is a description of installation and commissioning of the system at one of the MINOS detectors. The response normalization of each detector with cosmic ray muons is described. Special attention is paid to the explanation of necessary corrections that must be made to the muon sample in order for the sample to be used to calibrate each detector to the specified accuracy. The performance of the calibration is shown.

  18. The effects of earphones and music on the temperature measured by infrared tympanic thermmeter: preliminary results.

    Science.gov (United States)

    Palese, Alvisa; Pasqualini, Davide

    2014-01-01

    The main aim of the study was to evaluate the effect on subjects' temperature measurement readings when using the infrared tympanic thermometer after correct earphone placement and use, with or without music transmission through the earphone. A comparative study design was adopted. A sample of 39 healthy people was randomly divided into three groups. Subjects in all groups used an earphone that had been correctly placed in the right ear only: Group 1: listened to heavy metal music through the earphone (13 participants); Group 2: listened to classical music through the earphone (13 participants); Group 3: no music or sound was transmitted through the earphone (13 participants). Average differences (CI 95%) and Pearson correlations for the temperature measured in the right ear, which was exposed to the different independent variables, and the left ear which was not exposed, were calculated at different times: (1) after 10 minutes compared to the baseline measurement; (2) after 30 minutes compared to the 10 minutes measurement; and (3) after 30 minutes compared to the baseline measurement. The inter-ear temperature correlation at the baseline was Pearson r .801 (p = .01). There was a significant decrease in the correlations between right and left ear temperatures in Group 1 and in Group 3 which was demonstrated after 10 minutes of earphone use, and reached critical values after 30 minutes of use in all groups. The average warmth in the right ear, as perceived by participants after 20 minutes, was reported. Using the Numerical Rating Score the average was 3.3 +/- 1.3 for Group 1, for Group 2 was 1.9 +/- 1.3 and for Group 3 was 3.3 +/- 1.2 (p = .05). Within the limitations of the study, which involved a limited number of healthy people the results show that it is best to not measure tympanic temperature in an ear that has very recently had an earphone in place.

  19. Measuring acute rehabilitation needs in trauma: preliminary evaluation of the Rehabilitation Complexity Scale.

    Science.gov (United States)

    Hoffman, Karen; West, Anita; Nott, Philippa; Cole, Elaine; Playford, Diane; Liu, Clarence; Brohi, Karim

    2013-01-01

    Injury severity, disability and care dependency are frequently used as surrogate measures for rehabilitation requirements following trauma. The true rehabilitation needs of patients may be different but there are no validated tools for the measurement of rehabilitation complexity in acute trauma care. The aim of the study was to evaluate the potential utility of the Rehabilitation Complexity Scale (RCS) version 2 in measuring acute rehabilitation needs in trauma patients. A prospective observation study of 103 patients with traumatic injuries in a Major Trauma Centre. Rehabilitation complexity was measured using the RCS and disability was measured using the Barthel Index. Demographic information and injury characteristics were obtained from the trauma database. The RCS was closely correlated with injury severity (r=0.69, p<0.001) and the Barthel Index (r=0.91, p<0.001). However the Barthel was poor at discriminating between patients rehabilitation needs, especially for patients with higher injury severities. Of 58 patients classified as 'very dependent' by the Barthel, 21 (36%) had low or moderate rehabilitation complexity. The RCS correlated with acute hospital length of stay (r=0.64, p=<0.001) and patients with a low RCS were more likely to be discharged home. The Barthel which had a flooring effect (56% of patients classified as very dependent were discharged home) and lacked discrimination despite close statistical correlation. The RCS outperformed the ISS and the Barthel in its ability to identify rehabilitation requirements in relation to injury severity, rehabilitation complexity, length of stay and discharge destination. The RCS is potentially a feasible and useful tool for the assessment of rehabilitation complexity in acute trauma care by providing specific measurement of patients' rehabilitation requirements. A larger longitudinal study is needed to evaluate the RCS in the assessment of patient need, service provision and trauma system performance

  20. Measurement of the electrostatic charge in airborne particles: I - development of the equipment and preliminary results

    Directory of Open Access Journals (Sweden)

    Marra Jr. W.D.

    2000-01-01

    Full Text Available The design and construction of a equipment capable of measuring the electrostatic charges in aerosols, named the electrostatic charge classifier, were carried out. They were based on the concept of particle electromobility and the charge classifier was intended to classify the nature and the distribution of electrostatic charges as a function of particle size. The resulting piece of equipment is easy to dismount, which facilitates its cleaning and transport, and easy to operate. Early results indicate that the values of electrostatic charge measured on test particles are inside the range reported in the literature, indicating the adequacy of the technique utilized.

  1. Preliminary research on measuring grease in petroleum pipeline using fast neutron transmission method

    International Nuclear Information System (INIS)

    Liu Qingwei; Liu Shengkang; Zhang Zhiping; Ding Xiaoping

    2006-01-01

    The principle, experiment and conclusion on the grease stain measurement using fast neutron are reported. The experiment equipment consist of 241 Am-Be fast neutron source, ZnS detector and BH1224 multichannel spectrometer. Paraffin is used instead of real grease stain. Steel plates are used instead of pipeline. The results of the experiment indicate that there is a good linearship between the logarithm of the reciprocal of the neutron transmissivity and the paraffin thickness. The measuring accuracy of the paraffin thickness is 0.6 mm in this experiment. (authors)

  2. Preliminary measurements of the edge magnetic field pitch from 2-D Doppler backscattering in MAST and NSTX-U (invited)

    Science.gov (United States)

    Vann, R. G. L.; Brunner, K. J.; Ellis, R.; Taylor, G.; Thomas, D. A.

    2016-11-01

    The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI's active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI's 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field. In this paper, we present preliminary pitch angle measurements obtained by SAMI on the Mega Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy and on the National Spherical Torus Experiment Upgrade at Princeton Plasma Physics Laboratory. The results demonstrate encouraging agreement between SAMI and other independent measurements.

  3. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    Science.gov (United States)

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  4. Initial development and preliminary validation of a new negative symptom measure: the Clinical Assessment Interview for Negative Symptoms (CAINS).

    Science.gov (United States)

    Forbes, Courtney; Blanchard, Jack J; Bennett, Melanie; Horan, William P; Kring, Ann; Gur, Raquel

    2010-12-01

    As part of an ongoing scale development process, this study provides an initial examination of the psychometric properties and validity of a new interview-based negative symptom instrument, the Clinical Assessment Interview for Negative Symptoms (CAINS), in outpatients with schizophrenia or schizoaffective disorder (N = 37). The scale was designed to address limitations of existing measures and to comprehensively assess five consensus-based negative symptoms: asociality, avolition, anhedonia (consummatory and anticipatory), affective flattening, and alogia. Results indicated satisfactory internal consistency reliability for the total CAINS scale score and promising inter-rater agreement, with clear areas identified in need of improvement. Convergent validity was evident in general agreement between the CAINS and alternative negative symptom measures. Further, CAINS subscales significantly correlated with relevant self-report emotional experience measures as well as with social functioning. Discriminant validity of the CAINS was strongly supported by its small, non-significant relations with positive symptoms, general psychiatric symptoms, and depression. These preliminary data on an early beta-version of the CAINS provide initial support for this new assessment approach to negative symptoms and suggest directions for further scale development. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. A Measure of EFL Public Speaking Class Anxiety: Scale Development and Preliminary Validation and Reliability

    Science.gov (United States)

    Yaikhong, Kriangkrai; Usaha, Siriluck

    2012-01-01

    The present study contributes to developing a Public Speaking Class Anxiety Scale (PSCAS) to measure anxiety in the EFL public speaking class in the Thai context. Items were adopted from previous scales: Foreign Language Classroom Anxiety Scale (FLCAS) by Horwitz et al. (1986); Personal Report of Communication Apprehension (PRCA-24) and Personal…

  6. Experimentally Measured Susceptibility to Peer Influence and Adolescent Sexual Behavior Trajectories: A Preliminary Study

    Science.gov (United States)

    Choukas-Bradley, Sophia; Giletta, Matteo; Widman, Laura; Cohen, Geoffrey L.; Prinstein, Mitchell J.

    2014-01-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat room" paradigm involving…

  7. Experimentally measured susceptibility to peer influence and adolescent sexual behavior trajectories : A preliminary study

    NARCIS (Netherlands)

    Choukas-Bradley, S.; Giletta, M.; Widman, L.; Cohen, G.L.; Prinstein, M.J.

    2014-01-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat

  8. Preliminary results of oxygen isotope ratio measurement with a particle-gamma coincidence method

    Energy Technology Data Exchange (ETDEWEB)

    Borysiuk, Maciek, E-mail: maciek.borysiuk@pixe.lth.se; Kristiansson, Per; Ros, Linus; Abdel, Nassem S.; Elfman, Mikael; Nilsson, Charlotta; Pallon, Jan

    2015-04-01

    The possibility to study variations in the oxygen isotopic ratio with photon tagged nuclear reaction analysis (pNRA) is evaluated in the current work. The experiment described in the article was performed at Lund Ion Beam Analysis Facility (LIBAF) with a 2 MeV deuteron beam. Isotopic fractionation of light elements such as carbon, oxygen and nitrogen is the basis of many analytical tools in hydrology, geology, paleobiology and paleogeology. IBA methods provide one possible tool for measurement of isotopic content. During this experimental run we focused on measurement of the oxygen isotopic ratio. The measurement of stable isotopes of oxygen has a number of applications; the particular one driving the current investigation belongs to the field of astrogeology and specifically evaluation of fossil extraterrestrial material. There are three stable isotopes of oxygen: {sup 16}O, {sup 17}O and {sup 18}O. We procured samples highly enriched with all three isotopes. Isotopes {sup 16}O and {sup 18}O were easily detected in the enriched samples, but no significant signal from {sup 17}O was detected in the same samples. The measured yield was too low to detect {sup 18}O in a sample with natural abundances of oxygen isotopes, at least in the current experimental setup, but the spectral line from the reaction with {sup 16}O was clearly visible.

  9. Direct measurement of tritium production rate in LiPb with removed parasitic activities: Preliminary experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kuc, Tadeusz, E-mail: kuc@agh.edu.pl; Pohorecki, Władysław; Ostachowicz, Beata

    2014-10-15

    Liquid scintillation (LS) technique applied to direct measurement of tritium activity produced in LiPb eutectic in Frascati HCLL TBM mock-up neutronic experiment has been tested so far in the case of LS measurement after long period since irradiation. LiPb samples irradiated in neutron filed show, except of tritium, meaningful activity of other radioisotopes (parasitic). Parasitic activity, mainly from isotopes of lead ({sup 209}Pb, {sup 204m}Pb, {sup 203}Pb) calculated with the use of FISPACT, exceeds ca 5 times tritium activity 1.4 h after irradiation. We propose to remove disturbing radioisotopes in a chemical way to avoid long “cooling” of the irradiated samples before tritium measurement. Samples (1 g of LiPb) irradiated in reactor fast neutron flux were diluted and metallic cations removed by chemical precipitation. For this purpose we used: potassium iodide (KJ), strontium chloride (SrCl{sub 2}), APDC (C{sub 5}H{sub 8}NS{sub 2}·NH{sub 4}), NaDDTC (C{sub 5}H{sub 10}NNaS{sub 2}·3H{sub 2}O), and PAN (C{sub 15}H{sub 11}N{sub 3}O). Precipitation procedure in each case lasted ca 5–25 min, and the following filtration next 10–20 min. In each filtrate (ca 120 ml) we measured Pb concentration in total reflection X-ray fluorescence (TXRF) analyzer and parasitic activity (left after 21-day “cooling”) applying HPGe gamma spectrometer. Pb cations precipitated by SrCl{sub 2} and than by PAN lowered activity of Pb isotopes to less than 1% of the initial tritium activity. Another combination of reagents: NaDDTC followed by SrCl{sub 2} in a single and double step filtration reduced Pb concentration 10{sup 2} and 10{sup 4} times, respectively. Reduction of this order allows tritium radiometric measurement ca 3 h after irradiation with acceptable accuracy. This time can be shortened by applying correction for decay of known parasitic activity. Input of {sup 76}As and other less abundant radioisotopes can be eliminated using high purity LiPb. Tritium activity of

  10. Preliminary measurements of aromatic VOCs in public transportation modes in Guangzhou, China.

    Science.gov (United States)

    Chan, L Y; Lau, W L; Wang, X M; Tang, J H

    2003-07-01

    This study examined the exposure level of aromatic volatile organic compounds (VOCs) in public transportation modes in Guangzhou, China. A total of 40 VOC samples were conducted in four popular public commuting modes (subway, taxis, non-air-conditioned buses and air-conditioned buses) while traversing in urban areas of Guangzhou. Traffic-related VOCs (benzene, toluene, ethylbenzene, m/p-xylene and o-xylene) were collected on adsorbent tubes and analyzed by thermal desorption (TD) and gas chromatography/mass-selective detector (GC/MSD) technique. The results indicate that commuter exposure to VOCs is greatly influenced by the choice of public transport. For the benzene measured, the mean exposure level in taxis (33.6 microg/m(3)) was the highest and was followed by air-conditioned buses (13.5 microg/m(3)) and non-air-conditioned buses (11.3 microg/m(3)). The exposure level in the subway (7.6 microg/m(3)) is clearly lower than that in roadway transports. The inter-microenvironment variations of other target compounds were similar to that of benzene. The target VOCs were well correlated to each other in all the measured transports. The concentration profile of the measured transport was also investigated and was found to be similar to each other. Based on the experiment results, the average B/T/E/X found in this study was about (1.0/4.3/0.7/1.4). In this study, the VOC levels measured in evening peak hours were only slightly higher than those in afternoon non-peak hours. This is due to the insignificant change of traffic volume on the measured routes between these two set times. The out-dated vehicle emission controls and slow-moving traffic conditions may be the major reasons leading elevated in-vehicle exposure level in some public commuting journeys.

  11. Preliminary validation of assays to measure parameters of calcium metabolism in captive Asian and African elephants in western Europe.

    Science.gov (United States)

    van Sonsbeek, Gerda R; van der Kolk, Johannes H; van Leeuwen, Johannes P T M; Schaftenaar, Willem

    2011-05-01

    Hypocalcemia is a well known cause of dystocia in animals, including elephants in captivity. In order to study calcium metabolism in elephants, it is of utmost importance to use properly validated assays, as these might be prone to specific matrix effects in elephant blood. The aim of the current study was to conduct preliminary work for validation of various parameters involved in calcium metabolism in both blood and urine of captive elephants. Basal values of these parameters were compared between Asian elephants (Elephas maximus) and African elephants (Loxodonta africana). Preliminary testing of total calcium, inorganic phosphorus, and creatinine appeared valid for use in plasma and creatinine in urine in both species. Furthermore, measurements of bone alkaline phosphatase and N-terminal telopeptide of type I collagen appeared valid for use in Asian elephants. Mean heparinized plasma ionized calcium concentration and pH were not significantly affected by 3 cycles of freezing and thawing. Storage at 4 °C, room temperature, and 37 °C for 6, 12, and 24 hr did not alter the heparinized plasma ionized calcium concentration in Asian elephants. The following linear regression equation using pH (range: 6.858-7.887) and ionized calcium concentration in heparinized plasma was utilized: iCa(7.4) (mmol/l) = -2.1075 + 0.3130·pH(actual) + 0.8296·iCa(actual) (mmol/l). Mean basal values for pH and plasma in Asian elephant whole blood were 7.40 ± 0.048 and 7.49 ± 0.077, respectively. The urinary specific gravity and creatinine concentrations in both Asian and African elephants were significantly correlated and both were significantly lower in Asian elephants. © 2011 The Author(s)

  12. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  13. Development and Preliminary Validation of a New Measure of Values in Scientific Work.

    Science.gov (United States)

    English, Tammy; Antes, Alison L; Baldwin, Kari A; DuBois, James M

    2018-04-01

    In this paper we describe the development and initial psychometric evaluation of a new measure, the values in scientific work (VSW). This scale assesses the level of importance that investigators attach to different VSW. It taps a broad range of intrinsic, extrinsic, and social values that motivate the work of scientists, including values specific to scientific work (e.g., truth and integrity) and more classic work values (e.g., security and prestige) in the context of science. Notably, the values represented in this scale are relevant to scientists regardless of their career stage and research focus. We administered the VSW and a measure of global values to 203 NIH-funded investigators. Exploratory factor analyses suggest the delineation of eight VSW, including autonomy, research ethics, social impact, income, collaboration, innovation and growth, conserving relationships, and job security. These VSW showed predictable and distinct associations with global values. Implications of these findings for work on research integrity and scientific misconduct are discussed.

  14. Preliminary Validation of a New Measure of Negative Response Bias: The Temporal Memory Sequence Test.

    Science.gov (United States)

    Hegedish, Omer; Kivilis, Naama; Hoofien, Dan

    2015-01-01

    The Temporal Memory Sequence Test (TMST) is a new measure of negative response bias (NRB) that was developed to enrich the forced-choice paradigm. The TMST does not resemble the common structure of forced-choice tests and is presented as a temporal recall memory test. The validation sample consisted of 81 participants: 21 healthy control participants, 20 coached simulators, and 40 patients with acquired brain injury (ABI). The TMST had high reliability and significantly high positive correlations with the Test of Memory Malingering and Word Memory Test effort scales. Moreover, the TMST effort scales exhibited high negative correlations with the Glasgow Coma Scale, thus validating the previously reported association between probable malingering and mild traumatic brain injury. A suggested cutoff score yielded acceptable classification rates in the ABI group as well as in the simulator and control groups. The TMST appears to be a promising measure of NRB detection, with respectable rates of reliability and construct and criterion validity.

  15. The Measurement of Entrepreneurial Outsourcing: Preliminary Scale Development, Dimensionality Assessment, and Construct Validation

    Directory of Open Access Journals (Sweden)

    Ali Davari

    2015-08-01

    Full Text Available Studying the outsourcing concept, as a strategy for efficient and effective business management, has been implemented less in the field of entrepreneurship. Accordingly, the present study aims to develop a measurement instrument for measuring entrepreneurial outsourcing construct utilizing empirical evidence in Iran’s telecommunications and automotive industries. Employing a sample of 203 senior managers and executive experts of companies operating in these industries, the gathered data were analyzed using PLS-SEM method. According to our results, the proposed scale of entrepreneurial outsourcing comprises six dimensions: strategic factors, economical factors, technological factors, task specifications, risk relating factors, and entrepreneurial performance. Moreover, the scale enjoys sufficient multidimensionality, reliability, and construct validity in terms of convergent and discriminate validity.

  16. Measuring Problematic Mobile Phone Use: Development and Preliminary Psychometric Properties of the PUMP Scale

    OpenAIRE

    Merlo, Lisa J.; Stone, Amanda M.; Bibbey, Alex

    2013-01-01

    This study aimed to develop and assess the psychometric properties of an English language measure of problematic mobile phone use. Participants were recruited from a university campus, health science center, and other public locations. The sample included 244 individuals (68.4% female) aged 18–75. Results supported a unidimensional factor structure for the 20-item self-report Problematic Use of Mobile Phones (PUMP) Scale. Internal consistency was excellent (α = 0.94). Strong correlations (r =...

  17. Preliminary validation of FastaReada as a measure of reading fluency

    Directory of Open Access Journals (Sweden)

    Zena eElhassan

    2015-10-01

    Full Text Available Fluent reading is characterized by speed and accuracy in the decoding and comprehension of connected text. Although a variety of measures are available for the assessment of reading skills most tests do not evaluate rate of text recognition as reflected in fluent reading. Here we evaluate FastaReada, a customized computer-generated task that was developed to address some of the limitations of currently available measures of reading skills. FastaReada provides a rapid assessment of reading fluency quantified as words read per minute for connected, meaningful text. To test the criterion validity of FastaReada, 124 mainstream school children with typical sensory, mental and motor development were assessed. Performance on FastaReada was correlated with the established Neale Analysis of Reading Ability (NARA measures of text reading accuracy, rate and comprehension, and common single word measures of pseudoword (non-word reading, phonetic decoding, phonological awareness and mode of word decoding (i.e., visual or eidetic versus auditory or phonetic. The results demonstrated strong positive correlations between FastaReada performance and NARA reading rate (r = .75, accuracy (r = .83 and comprehension (r = .63 scores providing evidence for criterion-related validity. Additional evidence for criterion validity was demonstrated through strong positive correlations between FastaReada and both single word eidetic (r = .81 and phonetic decoding skills (r = .68. The results also demonstrated FastaReada to be a stronger predictor of eidetic decoding than the NARA rate measure, with FastaReada predicting 14.4% of the variance compared to 2.6% predicted by NARA rate. FastaReada was therefore deemed to be a valid tool for educators, clinicians, and research related assessment of reading accuracy and rate. As expected, analysis with hierarchical regressions also highlighted the closer relationship of fluent reading to rapid visual word recognition than to

  18. Development of a Duplex Ultrasound Simulator and Preliminary Validation of Velocity Measurements in Carotid Artery Models.

    Science.gov (United States)

    Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H

    2016-07-01

    Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error

  19. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    International Nuclear Information System (INIS)

    Anazodo, Udunna; Kewin, Matthew; Finger, Elizabeth; Thiessen, Jonathan; Hadway, Jennifer; Butler, John; Pavlosky, William; Prato, Frank; Thompson, Terry; St Lawrence, Keith

    2015-01-01

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  20. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Anazodo, Udunna; Kewin, Matthew [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Finger, Elizabeth [Department of Clinical Neurological Sciences, Western University, London, Ontario (Canada); Thiessen, Jonathan; Hadway, Jennifer; Butler, John [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Pavlosky, William [Diagnostic Imaging, St Joseph' s Health Care, London, Ontario (Canada); Prato, Frank; Thompson, Terry; St Lawrence, Keith [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada)

    2015-05-18

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  1. The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: anisotropic Baryon Acoustic Oscillations measurements in Fourier-space with optimal redshift weights

    Science.gov (United States)

    Wang, Dandan; Zhao, Gong-Bo; Wang, Yuting; Percival, Will J.; Ruggeri, Rossana; Zhu, Fangzhou; Tojeiro, Rita; Myers, Adam D.; Chuang, Chia-Hsun; Baumgarten, Falk; Zhao, Cheng; Gil-Marín, Héctor; Ross, Ashley J.; Burtin, Etienne; Zarrouk, Pauline; Bautista, Julian; Brinkmann, Jonathan; Dawson, Kyle; Brownstein, Joel R.; de la Macorra, Axel; Schneider, Donald P.; Shafieloo, Arman

    2018-06-01

    We present a measurement of the anisotropic and isotropic Baryon Acoustic Oscillations (BAO) from the extended Baryon Oscillation Spectroscopic Survey Data Release 14 quasar sample with optimal redshift weights. Applying the redshift weights improves the constraint on the BAO dilation parameter α(zeff) by 17 per cent. We reconstruct the evolution history of the BAO distance indicators in the redshift range of 0.8 < z < 2.2. This paper is part of a set that analyses the eBOSS DR14 quasar sample.

  2. Measurements of diagnostic examination performance using quantitative apparent diffusion coefficient and proton MR spectroscopic imaging in the preoperative evaluation of tumor grade in cerebral gliomas

    International Nuclear Information System (INIS)

    Server, Andres; Kulle, Bettina; Gadmar, Oystein B.; Josefsen, Roger; Kumar, Theresa; Nakstad, Per H.

    2011-01-01

    Purpose: Tumor grading is very important both in treatment decision and evaluation of prognosis. While tissue samples are obtained as part of most therapeutic approaches, factors that may result in inaccurate grading due to sampling error (namely, heterogeneity in tissue sampling, as well as tumor-grade heterogeneity within the same tumor specimen), have led to a desire to use imaging better to ascertain tumor grade. The purpose in our study was to evaluate the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the curve (AUC), and accuracy of diffusion-weighted MR imaging (DWI), proton MR spectroscopic imaging (MRSI) or both in grading primary cerebral gliomas. Materials and methods: We performed conventional MR imaging (MR), DWI, and MRSI in 74 patients with newly diagnosed brain gliomas: 59 patients had histologically verified high-grade gliomas: 37 glioblastomas multiform (GBM) and 22 anaplastic astrocytomas (AA), and 15 patients had low-grade gliomas. Apparent diffusion coefficient (ADC) values of tumor and peritumoral edema, and ADC ratios (ADC in tumor or peritumoral edema to ADC of contralateral white matter, as well as ADC in tumor to ADC in peritumoral edema) were determined from three regions of interest. The average of the mean, maximum, and minimum for ADC variables was calculated for each patient. The metabolite ratios of Cho/Cr and Cho/NAA at intermediate TE were assessed from spectral maps in the solid portion of tumor, peritumoral edema and contralateral normal-appearing white matter. Tumor grade determined with the two methods was then compared with that from histopathologic grading. Logistic regression and receiver operating characteristic (ROC) curve analysis were performed to determine optimum thresholds for tumor grading. Measures of diagnostic examination performance, such as sensitivity, specificity, PPV, NPV, AUC, and accuracy for identifying high-grade gliomas were also calculated

  3. Development and preliminary validation of the EASE: a tool to measure perceived singing voice function.

    Science.gov (United States)

    Phyland, Debra J; Pallant, Julie F; Benninger, Michael S; Thibeault, Susan L; Greenwood, Ken M; Smith, Julian A; Vallance, Neil

    2013-07-01

    Most voice self-rating tools are disease-specific measures and are not suitable for use with healthy voice users. There is a need for a tool that is sensitive to the subtleties of a singer's voice and to perceived physical changes in the singing voice mechanism as a function of load. The aim of this study was to devise and validate a scale to assess singer's perceptions of the current status of their singing voice. Ninety-five vocal health descriptors were collected from focus group interviews of singers. These were reviewed by 25 currently performing music theater (MT) singers. Based on a consensus technique, the number of descriptors was decreased to 42 items. These were administered to a sample of 284 professional MT singers using an online survey to evaluate their perception of current singing voice status. Principal component analysis identified two subsets of items. Rasch analysis was used to evaluate and refine these sets of items to form two 10-item subscales. Both subscales demonstrated good overall fit to the Rasch model, no differential item functioning by sex or age, and good internal consistency reliability. The two subscales were strongly correlated and subsequent Rasch analysis supported their combination to form a single 20-item scale with good psychometric properties. The Evaluation of the Ability to Sing Easily (EASE) is a concise clinical tool to assess singer's perceptions of the current status of their singing voice with good measurement properties. EASE may prove a useful tool to measure changes in the singing voice as indicators of the effect of vocal load. Furthermore, it may offer a valuable means for the prediction or screening of singers "at risk" of developing voice disorders. Copyright © 2013 The Voice Foundation. All rights reserved.

  4. Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor

    Directory of Open Access Journals (Sweden)

    Malchau Henrik

    2006-09-01

    Full Text Available Abstract Background There is currently a paucity of devices available for continuous, long-term monitoring of human joint motion. Non-invasive, inexpensive devices capable of recording human activity and joint motion have many applications for medical research. Such a device could be used to quantify range of motion outside the gait laboratory. The purpose of this study was to test the accuracy of the modified Intelligent Device for Energy Expenditure and Activity (IDEEA in measuring knee flexion angles, to detect different physical activities, and to quantify how often healthy subjects use deep knee flexion in the ambulatory setting. Methods We compared Biomotion Laboratory (BML "gold standard" data to simultaneous IDEEA measures of knee motion and gait, step up/down, and stair descent in 5 healthy subjects. In addition, we used a series of choreographed physical activities outside the BML to confirm the IDEEA's ability to accurately measure 7 commonly-performed physical activities. Subjects then continued data collection during ordinary activities outside the gait laboratory. Results Pooled correlations between the BML and IDEEA knee flexion angles were .97 +/- .03 for step up/down, .98 +/- .02 for stair descent, and .98 +/- .01 for gait. In the BML protocol, the IDEEA accurately identified gait, but was less accurate in identifying step up/down and stair descent. During sampling outside the BML, the IDEEA accurately detected walking, running, stair ascent, stair descent, standing, lying, and sitting. On average, subjects flexed their knees >120° for 0.17% of their data collection periods outside the BML. Conclusion The modified IDEEA system is a useful clinical tool for evaluating knee motion and multiple physical activities in the ambulatory setting. These five healthy subjects rarely flexed their knees >120°.

  5. Preliminary Results for a Monocular Marker-Free Gait Measurement System

    Directory of Open Access Journals (Sweden)

    Jane Courtney

    2006-01-01

    Full Text Available This paper presents results from a novel monocular marker-free gait measurement system. The system was designed for physical and occupational therapists to monitor the progress of patients through therapy. It is based on a novel human motion capturemethod derived from model-based tracking. Testing is performed on two monocular, sagittal-view, sample gait videos – one with both the environment and the subject’s appearance and movement restricted and one in a natural environment with unrestrictedclothing and motion. Results of the modelling, tracking and analysis stages are presented along with standard gait graphs and parameters.

  6. Fluid mechanics of needle valves with rounded components. Part II: Preliminary measurements

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2016-01-01

    Roč. 251, November (2016), s. 52-58 ISSN 0924-4247 R&D Projects: GA ČR GA13-23046S Institutional support: RVO:61388998 Keywords : needle valves * pressure measurements * valves Subject RIV: BK - Fluid Dynamics Impact factor: 2.499, year: 2016 http://ac.els-cdn.com/S092442471630440X/1-s2.0-S092442471630440X-main.pdf?_tid=45acccf4-951f-11e6-a831-00000aab0f02&acdnat=1476787402_bf349ff3cfc7a824c1a01397a9a5b8b3

  7. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: a preliminary study

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Boudousq, V.; Comte, F.; Eberle, M.C.; Zanca, M.; Kotzki, P.O.; Rossi, M.; Piot, C.; Raczka, F.; Davy, J.M.

    2001-01-01

    The aim of this preliminary study was to evaluate the accuracy of left and right ventricular output computed from a semi-automatic processing of tomographic radionuclide ventriculography data (TRVG) in comparison with the conventional thermodilution method. Twenty patients with various heart diseases were prospectively included in the study. Thermodilution and TRVG acquisitions were carried out on the same day for all patients. Analysis of gated blood pool slices was performed using a watershed-based segmentation algorithm. Right and left ventricular output measured by TRVG correlated well with the measurements obtained with thermodilution (r=0.94 and 0.91 with SEE=0.38 and 0.46 l/min, respectively, P<0.001). The limits of agreement for TRVG and thermodilution measurements were -0.78-1.20 l/min for the left ventricle and -0.34-1.16 l/min for the right ventricle. No significant difference was found between the results of TRVG and thermodilution with respect to left ventricular output (P=0.09). A small but significant difference was found between right ventricular output measured by TRVG and both left ventricular output measured by TRVG (mean difference=0.17 l/min, P=0.04) and thermodilution-derived cardiac output (mean difference=0.41 l/min, P=0.0001). It is concluded that the watershed-based semi-automatic segmentation of TRVG slices provides non-invasive measurements of right and left ventricular output and stroke volumes at equilibrium, in routine clinical settings. Further studies are necessary to check whether the accuracy of these measurements is good enough to permit correct assessment of intracardiac shunts. (orig.)

  8. Technical note: Evaluation of the uncertainties in (choline+creatine)/citrate ratios measured by proton MR spectroscopic imaging in patients suspicious for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zbyn, S.; Krssak, M.; Memarsadeghi, M.; Gholami, B.; Haitel, A.; Weber, M.; Helbich, T.H.; Trattnig, S.; Moser, E.; Gruber, S.

    2014-07-15

    The presented evaluation of the relative uncertainty (δ'CCC) of the (choline + creatine)/citrate (CC/C) ratios can provide objective information about the quality and diagnostic value of prostate MR spectroscopic imaging data. This information can be combined with the numeric values of CC/C ratios and provides metabolic-quality maps enabling accurate cancer detection and user-independent data evaluation. In addition, the prostate areas suffering most from the low precision of CC/C ratios (e. g., prostate base) were identified.

  9. Measurement of small bowel transit time by 99Tcm-SC imaging: preliminary clinical study

    International Nuclear Information System (INIS)

    Zhang Shaohua; Xu Jingying; Bei Lian; Zhu Chaohui; Ba Jiantao

    1999-01-01

    Objective: To develop a method of measuring small bowel transit time (SBTT) by 99 Tc m -sulfur collide (SC) imaging and to compare with the method of added lactose in the test meal. Methods: 20 healthy volunteers and 26 patients with gastrointestinal disorders were studied. In fasting state, the subjects were asked to ingest the 99 Tc m -SC labelled solid meal within 5 minutes, then the image acquisition was immediately started with SPECT. The images were acquired every 15 min during the first hour, at 30 min intervals during 2∼4 hours and hourly thereafter until 80% radioactivity had entered the colon. One week later, the same procedure of imaging with 15 g lactulose added in the test meal was performed. The regions of interest (ROIs) were taken at stomach and colon, and the SBTT was calculated by deconvolution or by subtraction of the 50% time of gastric emptying from the 50% time of colon filling. Results: 1) The mean SBTT of 20 healthy volunteers was (4.2 +- 0.5) h, oral-caecum transit time (OCTT) was (4.3 +- 0.6) h; lactulose shortened the SBTT by (1.8 +- 0.6) h; 2) 26 patients showed different results of SBTT due to their different gastrointestinal disorders bases. Conclusions: 99 Tc m -SC imaging was a noninvasive and useful method to measure SBTT. The added lactulose can shorten the examination time and help to identify the time of food to the ileocecal region

  10. Measurements and preliminary interpretation of K-Reactor foundation response to man-made seismic excitation

    International Nuclear Information System (INIS)

    Lee, R.C.; Stephenson, D.E.

    1992-01-01

    In support of the Savannah River Technology Center (SRTC) effort to develop K-Reactor seismic design basis ground motions, SRTC monitored local high-explosive tests at a ''free-field'' site adjacent to K-Reactor and on the -40 level on the foundation of K-Reactor. The high-explosive tests were part of the SRTC/United States Geological Survey (USGS) regional refraction and attenuation experiment that used deeply buried high explosive charges near New Ellenton, Snelling, and at more distant South Carolina sites. The primary purpose of the Reactor measurements are to compare the relative amplitude and frequency content of ambient noise and shot generated ground motions measured at the K-Reactor foundation level and in the ''free-field'' so that foundation effects to ground motions can be documented and possibly incorporated in the facility design basis. Data analysis indicates that one of the five high explosive tests provided sufficient excitations at K-Reactor to produce satisfactory signal-to-noise between about 1 Hz and 15 Hz. Within this frequency band, Fourier spectral amplitude ratios of motions recorded within the first 10 seconds of first motion show substantial reductions (30 endash 50%) on shot radial and transverse components for frequencies greater than about 3 to 5 Hz. Approximately 50% reductions between 10 to 15 Hz were seen on vertical component ratios, and amplifications of 100% at 4 Hz and 5 Hz endash 6 Hz

  11. A flexible Monte Carlo tool for patient or phantom specific calculations: comparison with preliminary validation measurements

    Science.gov (United States)

    Davidson, S.; Cui, J.; Followill, D.; Ibbott, G.; Deasy, J.

    2008-02-01

    The Dose Planning Method (DPM) is one of several 'fast' Monte Carlo (MC) computer codes designed to produce an accurate dose calculation for advanced clinical applications. We have developed a flexible machine modeling process and validation tests for open-field and IMRT calculations. To complement the DPM code, a practical and versatile source model has been developed, whose parameters are derived from a standard set of planning system commissioning measurements. The primary photon spectrum and the spectrum resulting from the flattening filter are modeled by a Fatigue function, cut-off by a multiplying Fermi function, which effectively regularizes the difficult energy spectrum determination process. Commonly-used functions are applied to represent the off-axis softening, increasing primary fluence with increasing angle ('the horn effect'), and electron contamination. The patient dependent aspect of the MC dose calculation utilizes the multi-leaf collimator (MLC) leaf sequence file exported from the treatment planning system DICOM output, coupled with the source model, to derive the particle transport. This model has been commissioned for Varian 2100C 6 MV and 18 MV photon beams using percent depth dose, dose profiles, and output factors. A 3-D conformal plan and an IMRT plan delivered to an anthropomorphic thorax phantom were used to benchmark the model. The calculated results were compared to Pinnacle v7.6c results and measurements made using radiochromic film and thermoluminescent detectors (TLD).

  12. Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results

    International Nuclear Information System (INIS)

    Ipek, Ali; Unal, Ozlem; Kartal, Merve Gulbiz; Arslan, Halil; Isik, Cetin; Bozkurt, Murat

    2015-01-01

    The purpose of this study was to evaluate strain ratio measurement of femoral cartilage using real-time elastosonography. Twenty-five patients with femoral cartilage pathology on MRI (study group) were prospectively compared with 25 subjects with normal findings on MRI (control group) using real-time elastosonography. Strain ratio measurements of pathologic and normal cartilage were performed and compared, both within the study group and between the two groups. Elastosonography colour-scale coding showed a colour change from blue to red in pathologic cartilage and only blue colour-coding in normal cartilage. In the study group, the median strain ratio was higher in pathologic cartilage areas compared to normal areas (median, 1.49 [interquartile range, 0.80-2.53] vs. median, 0.01 [interquartile range, 0.01-0.01], p < 0.001, respectively). The median strain ratio of the control group was 0.01 (interquartile range, 0.01-0.01), and there was no significant difference compared to normal areas of the study group. There was, however, a significant difference between the control group cartilage and pathologic cartilage of the study group (p < 0.001). Elastosonography may be an effective, easily accessible, and relatively simple tool to demonstrate pathologic cartilage and to differentiate it from normal cartilage in the absence of advanced imaging facility such as MRI. (orig.)

  13. The consultation and relational empathy (CARE) measure: development and preliminary validation and reliability of an empathy-based consultation process measure.

    Science.gov (United States)

    Mercer, Stewart W; Maxwell, Margaret; Heaney, David; Watt, Graham Cm

    2004-12-01

    Empathy is a key aspect of the clinical encounter but there is a lack of patient-assessed measures suitable for general clinical settings. Our aim was to develop a consultation process measure based on a broad definition of empathy, which is meaningful to patients irrespective of their socio-economic background. Qualitative and quantitative approaches were used to develop and validate the new measure, which we have called the consultation and relational empathy (CARE) measure. Concurrent validity was assessed by correlational analysis against other validated measures in a series of three pilot studies in general practice (in areas of high or low socio-economic deprivation). Face and content validity was investigated by 43 interviews with patients from both types of areas, and by feedback from GPs and expert researchers in the field. The initial version of the new measure (pilot 1; high deprivation practice) correlated strongly (r = 0.85) with the Reynolds empathy measure (RES) and the Barrett-Lennard empathy subscale (BLESS) (r = 0.63), but had a highly skewed distribution (skew -1.879, kurtosis 3.563). Statistical analysis, and feedback from the 20 patients interviewed, the GPs and the expert researchers, led to a number of modifications. The revised, second version of the CARE measure, tested in an area of low deprivation (pilot 2) also correlated strongly with the established empathy measures (r = 0.84 versus RES and r = 0.77 versus BLESS) but had a less skewed distribution (skew -0.634, kurtosis -0.067). Internal reliability of the revised version was high (Cronbach's alpha 0.92). Patient feedback at interview (n = 13) led to only minor modification. The final version of the CARE measure, tested in pilot 3 (high deprivation practice) confirmed the validation with the other empathy measures (r = 0.85 versus RES and r = 0.84 versus BLESS) and the face validity (feedback from 10 patients). These preliminary results support the validity and reliability of the CARE

  14. Measuring death-related anxiety in advanced cancer: preliminary psychometrics of the Death and Dying Distress Scale.

    Science.gov (United States)

    Lo, Christopher; Hales, Sarah; Zimmermann, Camilla; Gagliese, Lucia; Rydall, Anne; Rodin, Gary

    2011-10-01

    The alleviation of distress associated with death and dying is a central goal of palliative care, despite the lack of routine measurement of this outcome. In this study, we introduce the Death and Dying Distress Scale (DADDS), a new, brief measure we have developed to assess death-related anxiety in advanced cancer and other palliative populations. We describe its preliminary psychometrics based on a sample of 33 patients with advanced or metastatic cancer. The DADDS broadly captures distress about the loss of time and opportunity, the process of death and dying, and its impact on others. The initial version of the scale has a one-factor structure and good internal reliability. Dying and death-related distress was positively associated with depression and negatively associated with spiritual, emotional, physical, and functional well-being, providing early evidence of construct validity. This distress was relatively common, with 45% of the sample scoring in the upper reaches of the scale, suggesting that the DADDS may be a relevant outcome for palliative intervention. We conclude by presenting a revised 15-item version of the scale for further study in advanced cancer and other palliative populations.

  15. Measurement of H, He, C and O Cosmic ray primaries preliminary results from the CREAM II experiment

    CERN Document Server

    Mognet, Samuel

    The direct measurement of the energy spectrum and composition of the incoming cosmic-ray flux at multi-TeV energies is of great interest. A feature located somewhere between 1000-10,000 TeV in the all-particle spectrum, referred to as the ‘knee’ characterized by a steepening of the power-law flux, has been observed by ground-based detectors for many years. It is believed to be related to an upper limit or change in efficiency of the Galactic accelerators of cosmic rays and/or properties of the propagation of cosmic rays in the Galaxy. Presented here is a preliminary analysis of the flux of primary H, He, C and O cosmic-ray species measured using the CREAM II instrument. This analysis is conducted using the Penn State-built Timing Charge Detector, distinct from other charge detectors used in alternative published CREAM II results. The second Antarctic flight of the CREAM instrument had a ∼ 28 day flight in the 2005-2006 Antarctic flight season. The instrument was launched on December 16th 2005 from Willi...

  16. MEASURING PLACE ATTACHMENT TO CĂLIMANI NATIONAL PARK (ROMANIA AMONG LOCAL RESIDENTS AND TOURISTS. PRELIMINARY FINDINGS

    Directory of Open Access Journals (Sweden)

    IZABELA AMALIA MIHALCA

    2014-06-01

    Full Text Available Measuring Place Attachment to Călimani National Park (Romania among Local Residents and Tourists. Preliminary Findings. Understanding the attachments that people develop for certain places is an interesting area of study, but with little attention in Romanian empirical research. This study introduces the concepts of place identity and place dependence in relation to a specific area within the local culture of the Land of Dorna. Starting from previous studies carried on western samples, a research instrument measuring the degree and content of place attachment was translated and adapted. 86 respondents (52 residents and 34 tourists filled in the questionnaire. Comparing the degree of attachment, there was no significant difference among the two samples. However, local residents tended to display higher levels of place identity, while tourists displayed more emotional functionality to the study area. Place attachment is deeply embodied in the local culture. Due to the research design the generalization of the results is limited. However, this study may act as a starting point in researching other geographical mental spaces. The lands of Romania are unique social and cultural spaces with specific attachment patterns. Future studies should consider larger and representative samples in order to find additional patterns of attachment among residents and other individuals (e.g. tourists, visitors, new residents, other communities etc..

  17. Preliminary study on the correlation between color measurement of dyed polyester and its image files

    Science.gov (United States)

    Park, Y. K.; Park, Y. C.

    2017-10-01

    As the internet becomes more popular, buyers send image files to manufacturers instead of sending swatches. However, this method may cause problems because different from the monitor between the buyer and the manufacturer, and also there is a problem depending on the light source. In order to overcome these problems, we investigated the relationship between color measurement values of dyed fabrics and RGB values of image files. The RGB values of image files tended to decrease with increasing dye concentration in all three colors. Correlation between RGB values and a*, b* values was observed at low concentration, but there was little correlation at high concentration. In the case of yellow color, there is no correlation between the L*a*b* values obtained from the dyed fabric and RGB values obtained from the image file.

  18. Measurement of carbon activity of sodium using nickel tabs and the Harwell Carbon Meter - Preliminary experience

    International Nuclear Information System (INIS)

    Blundell, A.; Thorley, A.W.

    1980-01-01

    Carbon can have an important effect on the mechanical properties of certain constructional materials likely to be used in the LMFBRs. Transfer of carbon will occur between the metal and the sodium at any particular location to bring the chemical potential of carbon in both components to the sam: value. Thus, in a mixed system containing austenitic stainless steel and unstabilized ferritic steel, carbon could be transferred by the sodium from the high carbon activity ferritic to the lower activity austenitic steel. Loss of carbon from the unstabilized ferritic steel leads to a weaker, more ductile material, while carburization of the stainless steel could lead to its embrittlement. Similarly carbon entering the coolant in the form of oil from leaking mechanical pumps could have similar effects on the mechanical property of stainless steels. In the light of these possibilities it is essential to measure the carbon activity of the sodium so that its effect on materials properties can be predicted

  19. Measurement of carbon activity of sodium using nickel tabs and the Harwell Carbon Meter - Preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Blundell, A; Thorley, A W [UKAEA, Risley, Warrington, Cheshire (United Kingdom)

    1980-05-01

    Carbon can have an important effect on the mechanical properties of certain constructional materials likely to be used in the LMFBRs. Transfer of carbon will occur between the metal and the sodium at any particular location to bring the chemical potential of carbon in both components to the sam: value. Thus, in a mixed system containing austenitic stainless steel and unstabilized ferritic steel, carbon could be transferred by the sodium from the high carbon activity ferritic to the lower activity austenitic steel. Loss of carbon from the unstabilized ferritic steel leads to a weaker, more ductile material, while carburization of the stainless steel could lead to its embrittlement. Similarly carbon entering the coolant in the form of oil from leaking mechanical pumps could have similar effects on the mechanical property of stainless steels. In the light of these possibilities it is essential to measure the carbon activity of the sodium so that its effect on materials properties can be predicted.

  20. Long-term measurements of radon concentrations in the living environments in Japan: A preliminary report

    International Nuclear Information System (INIS)

    Aoyama, T.; Yonehara, H.; Sakanove, M.; Kobayashi, S.; Iwasaki, T.; Mifune, M.; Radford, E.P.; Kato, H.

    1987-01-01

    Measurements of indoor radon (Rn-222) concentrations were carried out using bare track detectors (CR-39) in Mihama, Misasa, Hiroshima and Nagasaki for one year and using Terradex SF detectors in Hokkaido for a winter. The highest median value, 31.2 Bq/m/sup 3/, was from the Mihama survey and the lowest, 10.2 Bq/m/sup 3/ was obtained from Nagasaki. The median value for Misasa (a radioactive spa area) was 24.2 Bq/m/sup 3/ and that for Hiroshima was 23.10 Bq/m/sup 3/. The values for Japanese traditional wooden houses were unexpectedly higher than these for ferro-concrete and prefabricated houses. The difference between the first and upper floors was modest. The median value obtained from personal monitoring of 25 people living in Missasa was 23.0 Bq/m/sup 3/, very close to the value found in dwellings in this area

  1. Measurement of {sup 238}Np fission cross-section by neutrons near thermal point (preliminary results)

    Energy Technology Data Exchange (ETDEWEB)

    Abramo; vich, S.N.; Andreev, M.F.; Bol`shakov, Y.M. [Institute of Experimental Physics, Arzamas (Russian Federation)] [and others

    1995-10-01

    Measurements have been carried out of {sup 238}Np fission cross-section by thermal neutrons. The isotope {sup 238}Np was built up through the reaction {sup 238}U(p,n) on an electrostatic accelerator. Extraction and cleaning of the sample were done by ion-exchange chromatography. Fast neutrons were generated on the electrostatic accelerator through the reaction {sup 9}Be(d,n); a polyethylene block was used to slow down neutrons. Registration of fission fragments was performed with dielectric track detectors. Suggesting that the behavior of {sup 238}Np and {sup 238}U. Westscott`s factors are indentical the fission cross-section of {sup 238}Np was obtained: {sigma}{sub fo}=2110 {plus_minus} 75 barn.

  2. Measuring mumbo jumbo: A preliminary quantification of the use of jargon in science communication.

    Science.gov (United States)

    Sharon, Aviv J; Baram-Tsabari, Ayelet

    2014-07-01

    Leaders of the scientific community encourage scientists to learn effective science communication, including honing the skill to discuss science with little professional jargon. However, avoiding jargon is not trivial for scientists for several reasons, and this demands special attention in teaching and evaluation. Despite this, no standard measurement for the use of scientific jargon in speech has been developed to date. Here a standard yardstick for the use of scientific jargon in spoken texts, using a computational linguistics approach, is proposed. Analyzed transcripts included academic speech, scientific TEDTalks, and communication about the discovery of a Higgs-like boson at CERN. Findings suggest that scientists use less jargon in communication with a general audience than in communication with peers, but not always less obscure jargon. These findings may lay the groundwork for evaluating the use of jargon.

  3. A nearly on-axis spectroscopic system for simultaneously measuring UV-visible absorption and X-ray diffraction in the SPring-8 structural genomics beamline.

    Science.gov (United States)

    Sakaguchi, Miyuki; Kimura, Tetsunari; Nishida, Takuma; Tosha, Takehiko; Sugimoto, Hiroshi; Yamaguchi, Yoshihiro; Yanagisawa, Sachiko; Ueno, Go; Murakami, Hironori; Ago, Hideo; Yamamoto, Masaki; Ogura, Takashi; Shiro, Yoshitsugu; Kubo, Minoru

    2016-01-01

    UV-visible absorption spectroscopy is useful for probing the electronic and structural changes of protein active sites, and thus the on-line combination of X-ray diffraction and spectroscopic analysis is increasingly being applied. Herein, a novel absorption spectrometer was developed at SPring-8 BL26B2 with a nearly on-axis geometry between the X-ray and optical axes. A small prism mirror was placed near the X-ray beamstop to pass the light only 2° off the X-ray beam, enabling spectroscopic analysis of the X-ray-exposed volume of a crystal during X-ray diffraction data collection. The spectrometer was applied to NO reductase, a heme enzyme that catalyzes NO reduction to N2O. Radiation damage to the heme was monitored in real time during X-ray irradiation by evaluating the absorption spectral changes. Moreover, NO binding to the heme was probed via caged NO photolysis with UV light, demonstrating the extended capability of the spectrometer for intermediate analysis.

  4. A preliminary report on methods of measuring and reducing Argon-41 production by a TRIGA reactor

    International Nuclear Information System (INIS)

    Smith, W.L.

    1972-01-01

    Methods to accurately determine and techniques to reduce the Argon-41 released from the one-megawatt Geological Survey TRIGA Reactor facility have been developed. Knowledge of the composition of the exhaust-gas effluent is of prime importance to the U.S. Geological Survey in minimizing all radioactive releases to the environment. The counting systems and control measures have enabled the Geological Survey TRIGA Reactor staff to reduce the amount of Argon-41 released from the facility by a factor of two, with no reduction in operation level of the reactor. The counting system has also enabled the staff to categorize the principal sources of Argon-41. Under normal conditions, a fully-loaded rotating-specimen rack is by far the largest contributor. With the current counting system, 10 -7 microcuries per cubic centimeter can be detected in the exhaust stack. It is intended to further improve this system to increase both the sensitivity and the reliability. The sensitivity is expected to be increased by utilizing a larger counting volume. To improve the reliability, it is planned to fabricate a loop parallel to the exhaust system, eliminating the need for a separate pump. (author)

  5. 36Cl/Cl ratios in geothermal systems: preliminary measurements from the Coso Field

    International Nuclear Information System (INIS)

    Nimz, G.J.; Moore, J.N.; Kasameyer, P.W.

    1997-01-01

    The 36 Cl/Cl isotopic composition of chlorine in geothermal systems can be a useful diagnostic tool in characterizing hydrologic structure, in determining the origins and age of waters within the systems, and in differentiating the sources of chlorine (and other solutes) in the thermal waters. The 36 Cl/Cl values for several geothermal water samples and reservoir host rock samples from the Coso, California geothermal field have been measured for these purposes. The results indicate that most of the chlorine is not derived from the dominant granitoid that host the geothermal system. If the chlorine was originally input into the Coso subsurface through meteoric recharge, that input occurred at least 1-1.25 million years ago. The results suggest that the thermal waters could be connate waters derived from sedimentary formations, presumably underlying and adjacent top the granitic rocks, which have recently migrated into the host rocks. Alternatively, most of the chlorine but not the water, may have recently input into the system from magmatic sources. In either case, the results indicate that most of the chlorine in the thermal waters has existed within the granitoid host rocks for no more than about 100,00-200,00 years. this residence time for the chlorine is similar to residence times suggested by other researchers for chlorine in deep groundwaters of the Mono Basin north of the Coso field

  6. 36Cl/Cl ratios in geothermal systems: preliminary measurements from the Coso Field

    Energy Technology Data Exchange (ETDEWEB)

    Nimz, G.J.; Moore, J.N.; Kasameyer, P.W.

    1997-07-01

    The {sub 36}Cl/Cl isotopic composition of chlorine in geothermal systems can be a useful diagnostic tool in characterizing hydrologic structure, in determining the origins and age of waters within the systems, and in differentiating the sources of chlorine (and other solutes) in the thermal waters. The {sub 36}Cl/Cl values for several geothermal water samples and reservoir host rock samples from the Coso, California geothermal field have been measured for these purposes. The results indicate that most of the chlorine is not derived from the dominant granitoid that host the geothermal system. If the chlorine was originally input into the Coso subsurface through meteoric recharge, that input occurred at least 1-1.25 million years ago. The results suggest that the thermal waters could be connate waters derived from sedimentary formations, presumably underlying and adjacent top the granitic rocks, which have recently migrated into the host rocks. Alternatively, most of the chlorine but not the water, may have recently input into the system from magmatic sources. In either case, the results indicate that most of the chlorine in the thermal waters has existed within the granitoid host rocks for no more than about 100,00-200,00 years. this residence time for the chlorine is similar to residence times suggested by other researchers for chlorine in deep groundwaters of the Mono Basin north of the Coso field.

  7. A preliminary study to measure and develop job satisfaction scale for medical teachers

    Science.gov (United States)

    Bhatnagar, Kavita; Srivastava, Kalpana; Singh, Amarjit; Jadav, S.L.

    2011-01-01

    Background: Job satisfaction of medical teachers has an impact on quality of medical education and patient care. In this background, the study was planned to develop scale and measure job satisfaction status of medical teachers. Materials and Methods: To generate items pertaining to the scale of job satisfaction, closed-ended and open-ended questionnaires were administered to medical professionals. The job satisfaction questionnaire was developed and rated on Likert type of rating scale. Both quantitative and qualitative methods were used to ascertain job satisfaction among 245 health science faculty of an autonomous educational institution. Factor loading was calculated and final items with strong factor loading were selected. Data were statistically evaluated. Results: Average job satisfaction score was 53.97 on a scale of 1–100. The Cronbach's alpha reliability coefficient was 0.918 for entire set of items. There was statistically significant difference in job satisfaction level across different age groups (P 0.0358) showing a U-shaped pattern and fresh entrants versus reemployed faculty (P 0.0188), former showing lower satisfaction. Opportunity for self-development was biggest satisfier, followed by work, opportunity for promotion, and job security. Factors contributing toward job dissatisfaction were poor utilization of skills, poor promotional prospects, inadequate pay and allowances, work conditions, and work atmosphere. Conclusion: Tertiary care teaching hospitals in autonomous educational institutions need to build infrastructure and create opportunities for their medical professional. Job satisfaction of young entrants needs to be raised further by improving their work environment. This will pave the way for effective delivery of health care. PMID:23271862

  8. Preliminary development of a revised version of the School Climate Measure.

    Science.gov (United States)

    Zullig, Keith J; Collins, Rani; Ghani, Nadia; Hunter, Amy A; Patton, Jon M; Huebner, E Scott; Zhang, Jianjun

    2015-09-01

    The School Climate Measure (SCM) was developed and preliminarily validated in 2010 and extended upon in 2013 in response to a dearth of psychometrically sound school climate instruments. This study sought to further validate the SCM on a large diverse sample of Arizona public school adolescents (N = 1,643) with two new domains. The eight original SCM domains (Positive Student-Teacher Relationships, School Connectedness, Academic Support, Order and Discipline, Physical Environment, Social Environment, Perceived Exclusion, and Academic Satisfaction) and two newly developed domains (Parental Involvement and Opportunities for Student Engagement) were subjected to psychometric analysis. The sample was randomly split into exploratory and confirmatory halves and subjected to factor analytic and structural equation modeling techniques. Factor analysis confirmed a 10-factor solution (loadings with absolute values > .40). Item factor loadings ranged from .47 to .95. Coefficient alphas ranged from .70 to .92. Fit statistics indicated a good fitting model (χ2 = 1452.67 [df = 734, p < .01], CFI = .94, TLI = .93, RMSEA = .039). This process eliminated some original SCM items, but the overall SCM increased only from 39 to 42 items with the newly developed domains. This investigation adds to the existing evidence for the SCM and offers support for a more comprehensive version of the SCM. The addition of the Parental Involvement and Opportunities for Student Engagement domains should further enhance the usefulness of the SCM. The SCM can facilitate data-driven decisions and may be incorporated into evidenced-based processes designed to improve important student learning and well-being outcomes. (c) 2015 APA, all rights reserved.

  9. A preliminary study to measure and develop job satisfaction scale for medical teachers.

    Science.gov (United States)

    Bhatnagar, Kavita; Srivastava, Kalpana; Singh, Amarjit; Jadav, S L

    2011-07-01

    Job satisfaction of medical teachers has an impact on quality of medical education and patient care. In this background, the study was planned to develop scale and measure job satisfaction status of medical teachers. To generate items pertaining to the scale of job satisfaction, closed-ended and open-ended questionnaires were administered to medical professionals. The job satisfaction questionnaire was developed and rated on Likert type of rating scale. Both quantitative and qualitative methods were used to ascertain job satisfaction among 245 health science faculty of an autonomous educational institution. Factor loading was calculated and final items with strong factor loading were selected. Data were statistically evaluated. Average job satisfaction score was 53.97 on a scale of 1-100. The Cronbach's alpha reliability coefficient was 0.918 for entire set of items. There was statistically significant difference in job satisfaction level across different age groups (P 0.0358) showing a U-shaped pattern and fresh entrants versus reemployed faculty (P 0.0188), former showing lower satisfaction. Opportunity for self-development was biggest satisfier, followed by work, opportunity for promotion, and job security. Factors contributing toward job dissatisfaction were poor utilization of skills, poor promotional prospects, inadequate pay and allowances, work conditions, and work atmosphere. Tertiary care teaching hospitals in autonomous educational institutions need to build infrastructure and create opportunities for their medical professional. Job satisfaction of young entrants needs to be raised further by improving their work environment. This will pave the way for effective delivery of health care.

  10. A preliminary study to measure and develop job satisfaction scale for medical teachers

    Directory of Open Access Journals (Sweden)

    Kavita Bhatnagar

    2011-01-01

    Full Text Available Background: Job satisfaction of medical teachers has an impact on quality of medical education and patient care. In this background, the study was planned to develop scale and measure job satisfaction status of medical teachers. Materials and Methods: To generate items pertaining to the scale of job satisfaction, closed-ended and open-ended questionnaires were administered to medical professionals. The job satisfaction questionnaire was developed and rated on Likert type of rating scale. Both quantitative and qualitative methods were used to ascertain job satisfaction among 245 health science faculty of an autonomous educational institution. Factor loading was calculated and final items with strong factor loading were selected. Data were statistically evaluated. Results: Average job satisfaction score was 53.97 on a scale of 1-100. The Cronbach′s alpha reliability coefficient was 0.918 for entire set of items. There was statistically significant difference in job satisfaction level across different age groups (P 0.0358 showing a U-shaped pattern and fresh entrants versus reemployed faculty (P 0.0188, former showing lower satisfaction. Opportunity for self-development was biggest satisfier, followed by work, opportunity for promotion, and job security. Factors contributing toward job dissatisfaction were poor utilization of skills, poor promotional prospects, inadequate pay and allowances, work conditions, and work atmosphere. Conclusion: Tertiary care teaching hospitals in autonomous educational institutions need to build infrastructure and create opportunities for their medical professional. Job satisfaction of young entrants needs to be raised further by improving their work environment. This will pave the way for effective delivery of health care.

  11. Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly

    Directory of Open Access Journals (Sweden)

    Lerman Y

    2011-08-01

    = 0.304, corresponding to mean INR and PT values of 1.07 (SD = 0.3; control group, INR and PT ≥ 1 (N = 32, mean TMI = 1.24 (SD = 0.32. R2 of all control and warfarin patients (N = 67 was 0.55 (P < 0.00001. In summary, the newly introduced TMI index is significantly correlated with INR and PT values.Keywords: anticoagulant monitoring, elderly, noninvasive coagulability index, noninvasive measurement

  12. Spectroscopic surveys of LAMOST

    International Nuclear Information System (INIS)

    Zhao Yongheng

    2015-01-01

    The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST), a new type of reflecting Schmidt telescope, has been designed and produced in China. It marks a breakthrough for large scale spectroscopic survey observation in that both large aperture and wide field of view have been achieved. LAMOST has the highest spectrum acquisition rate, and from October 2011 to June 2014 it has obtained 4.13 million spectra of celestial objects, of which 3.78 million are spectra of stars, with the stellar parameters of 2.20 million stars included. (author)

  13. Depth-resolved ultra-violet spectroscopic photo current-voltage measurements for the analysis of AlGaN/GaN high electron mobility transistor epilayer deposited on Si

    International Nuclear Information System (INIS)

    Ozden, Burcu; Yang, Chungman; Tong, Fei; Khanal, Min P.; Mirkhani, Vahid; Sk, Mobbassar Hassan; Ahyi, Ayayi Claude; Park, Minseo

    2014-01-01

    We have demonstrated that the depth-dependent defect distribution of the deep level traps in the AlGaN/GaN high electron mobility transistor (HEMT) epi-structures can be analyzed by using the depth-resolved ultra-violet (UV) spectroscopic photo current-voltage (IV) (DR-UV-SPIV). It is of great importance to analyze deep level defects in the AlGaN/GaN HEMT structure, since it is recognized that deep level defects are the main source for causing current collapse phenomena leading to reduced device reliability. The AlGaN/GaN HEMT epi-layers were grown on a 6 in. Si wafer by metal-organic chemical vapor deposition. The DR-UV-SPIV measurement was performed using a monochromatized UV light illumination from a Xe lamp. The key strength of the DR-UV-SPIV is its ability to provide information on the depth-dependent electrically active defect distribution along the epi-layer growth direction. The DR-UV-SPIV data showed variations in the depth-dependent defect distribution across the wafer. As a result, rapid feedback on the depth-dependent electrical homogeneity of the electrically active defect distribution in the AlGaN/GaN HEMT epi-structure grown on a Si wafer with minimal sample preparation can be elucidated from the DR-UV-SPIV in combination with our previously demonstrated spectroscopic photo-IV measurement with the sub-bandgap excitation.

  14. Depth-resolved ultra-violet spectroscopic photo current-voltage measurements for the analysis of AlGaN/GaN high electron mobility transistor epilayer deposited on Si

    Energy Technology Data Exchange (ETDEWEB)

    Ozden, Burcu; Yang, Chungman; Tong, Fei; Khanal, Min P.; Mirkhani, Vahid; Sk, Mobbassar Hassan; Ahyi, Ayayi Claude; Park, Minseo, E-mail: park@physics.auburn.edu [Department of Physics, Auburn University, Auburn, Alabama 36849 (United States)

    2014-10-27

    We have demonstrated that the depth-dependent defect distribution of the deep level traps in the AlGaN/GaN high electron mobility transistor (HEMT) epi-structures can be analyzed by using the depth-resolved ultra-violet (UV) spectroscopic photo current-voltage (IV) (DR-UV-SPIV). It is of great importance to analyze deep level defects in the AlGaN/GaN HEMT structure, since it is recognized that deep level defects are the main source for causing current collapse phenomena leading to reduced device reliability. The AlGaN/GaN HEMT epi-layers were grown on a 6 in. Si wafer by metal-organic chemical vapor deposition. The DR-UV-SPIV measurement was performed using a monochromatized UV light illumination from a Xe lamp. The key strength of the DR-UV-SPIV is its ability to provide information on the depth-dependent electrically active defect distribution along the epi-layer growth direction. The DR-UV-SPIV data showed variations in the depth-dependent defect distribution across the wafer. As a result, rapid feedback on the depth-dependent electrical homogeneity of the electrically active defect distribution in the AlGaN/GaN HEMT epi-structure grown on a Si wafer with minimal sample preparation can be elucidated from the DR-UV-SPIV in combination with our previously demonstrated spectroscopic photo-IV measurement with the sub-bandgap excitation.

  15. Valence effects on adsorption: a preliminary assessment of the effects on valence state control on sorption measurements

    International Nuclear Information System (INIS)

    Meyer, R.E.; Arnold, W.D.; Case, F.; Shiao, S.Y.; Palmer, D.A.

    1983-01-01

    Electrochemical arguments are advanced to illustrate that what is usually measured in practice is a mixed potential determined by the kinetics of the electrode processes occurring at the indicator electrode. Valence states can be altered electrochemically or by use of added chemical reagents, including redox couples which can hold the potential to relatively specific potentials. The disadvantage of added chemical reagents is that they may alter the characteristics of the sorption reactions by interaction with the sorbent. Electrochemical methods are versatile and do not add reagents, but in some caes the nuclide can adsorb on the electrode itself. A description is given of the application of the electrochemical method of valence control to determination of sorption of Np(V) on alumina. Valence state control and analysis can be used to study possible redox reactions on materials which might be used as backfill materials. A description is given of survey experiments with a number of sulfides and iron-containing materials. Valence state analysis is used on the initial solutions and leachate from acid leaches of the sorbent after the sorption experiment to help determine whether valence state change is occurring. The preliminary results indicate that on the sulfides tested, sorption occurs both with and without valence state change

  16. PRELIMINARY RESULTS IN SYNCHROTRON X-RAY DIFFRACTION MEASUREMENTS OF RUBBER COMPOSITES STRUCTURE BEFORE AND AFTER EXPOSURE TO HYDROGEN

    Directory of Open Access Journals (Sweden)

    Francesca Cosmi

    2011-05-01

    Full Text Available In future years, fuel cells are expected to represent a promising technology as a source of heat and electricity in buildings and of electrical power for vehicles, since fossil fuels are exhausting and significantly degrade air quality. It is well known that, when exposed to a hydrogen environment, hydrogen embrittlerment may affect materials such as iron and steel. But these are not the only materials that are used for hydrogen equipment. In particular, the rubber materials used for O–rings that seal high pressure hydrogen gas equipment show problems of internal fracture, called blister fracture, when the gas is rapidly decompressed. As many different kinds of fillers can be used, in this work we started to investigate the influence of the type of filler on the rubber composites structure, by means of X-ray diffraction measurements performed at the Elettra synchrotron radiation facility in Trieste. In this preliminary study, three kinds of samples were analyzed before and after exposure to hydrogen: Sulphur vulcanized EPDM, Peroxide vulcanized EPDM and Sulphur vulcanized NBR. While Peroxide vulcanized samples did not show significant differences in the diffraction pattern, changes could be detected in the cristalline form of Sulfure vulcanized rubber.

  17. Measurement of the sign of the spectroscopic quadrupole moment for the 2$_{1}^{+}$ state in $^{70}$Se no evidence for oblate shape

    CERN Document Server

    Hurst, A M

    2007-01-01

    Using a method whereby molecular and atomic ions are independently selected, an isobarically pure beam of 70Se ions was postaccelerated to an energy of 206 MeV using REX-ISOLDE. Coulomb-excitation yields for states in the beam and target nuclei were deduced by recording deexcitation γ rays in the highly segmented MINIBALL γ-ray spectrometer in coincidence with scattered particles in a silicon detector. At these energies, the Coulomb-excitation yield for the first 2+ state is expected to be strongly sensitive to the sign of the spectroscopic quadrupole moment through the nuclear reorientation effect. Experimental evidence is presented here for a prolate shape for the first 2+ state in 70Se, reopening the question over whether there are, as reported earlier, deformed oblate shapes near to the ground state in the light selenium isotopes.

  18. Shell model and spectroscopic factors

    International Nuclear Information System (INIS)

    Poves, P.

    2007-01-01

    In these lectures, I introduce the notion of spectroscopic factor in the shell model context. A brief review is given of the present status of the large scale applications of the Interacting Shell Model. The spectroscopic factors and the spectroscopic strength are discussed for nuclei in the vicinity of magic closures and for deformed nuclei. (author)

  19. Spectroscopic databases - A tool for structure elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Luksch, P [Fachinformationszentrum Karlsruhe, Gesellschaft fuer Wissenschaftlich-Technische Information mbH, Eggenstein-Leopoldshafen (Germany)

    1990-05-01

    Spectroscopic databases have developed to useful tools in the process of structure elucidation. Besides the conventional library searches, new intelligent programs have been added, that are able to predict structural features from measured spectra or to simulate for a given structure. The example of the C13NMR/IR database developed at BASF and available on STN is used to illustrate the present capabilities of online database. New developments in the field of spectrum simulation and methods for the prediction of complete structures from spectroscopic information are reviewed. (author). 10 refs, 5 figs.

  20. Photoelectric Radial Velocities, Paper XIX Additional Spectroscopic ...

    Indian Academy of Sciences (India)

    ian velocity curve that does justice to the measurements, but it cannot be expected to have much predictive power. Key words. Stars: late-type—stars: radial velocities—spectroscopic binaries—orbits. 0. Preamble. The 'Redman K stars' are a lot of seventh-magnitude K stars whose radial velocities were first observed by ...

  1. Preliminary Analysis of Chinese GF-3 SAR Quad-Polarization Measurements to Extract Winds in Each Polarization

    Directory of Open Access Journals (Sweden)

    Lin Ren

    2017-11-01

    Full Text Available This study analyzed the noise equivalent sigma zero (NESZ and ocean wind sensitivity for Chinese C-band Gaofen-3 (GF-3 quad-polarization synthetic aperture radar (SAR measurements to facilitate further operational wind extraction from GF-3 data. Data from the GF-3 quad-polarization SAR and collocated winds from both NOAA/NCEP Global Forecast System (GFS atmospheric model and National Data Buoy Center (NDBC buoys were used in the analysis. For NESZ, the co-polarization was slightly higher compared to the cross-polarization. Regarding co-polarization and cross-polarization, NESZ was close to RadarSAT-2 and Sentinel-1 A. Wind sensitivity was analyzed by evaluating the dependence on winds in terms of normalized radar cross-sections (NRCS and polarization combinations. The closest geophysical model function (GMF and the polarization ratio (PR model to GF-3 data were determined by comparing data and the model results. The dependence of co-polarized NRCS on wind speed and azimuth angle was consistent with the proposed GMF models. The combination of CMOD5 and CMOD5.N was considered to be the closest GMF in co-polarization. The cross-polarized NRCS exhibited a strong linear relationship with moderate wind speeds higher than 4 m·s−1, but a weak correlation with the azimuth angle. The proposed model was considered as the closest GMF in cross-polarization. For polarization combinations, PR and polarization difference (PD were considered. PR increased only with the incidence angle, whereas PD increased with wind speed and varied with azimuth angle. There were three very close PR models and each can be considered as the closest. Preliminary results indicate that GF-3 quad-polarization data are valid and have the ability to extract winds in each polarization.

  2. Improvement of the spectroscopic investigation of pellet ablation clouds

    International Nuclear Information System (INIS)

    Koubiti, M.; Ferri, S.; Godbert-Mouret, L.; Marandet, Y.; Rosato, J.; Stamm, R.; Goto, M.; Morita, S.

    2012-11-01

    The method allowing the characterization of the so-called ablation cloud of a pellet from its spectroscopic emission lines (intensities and shapes) is described. It is illustrated using measurements concerning carbon and aluminum pellets injected in the Large Helical Devices (LHD). The electron densities in pellet ablation clouds are sufficiently high that the energy levels of the main emitting species are at Local Thermodynamic Equilibrium (LTE). This justifies the electron temperature determination from the measured intensities using Boltzmann plots. In the case of carbon pellet, the C II 723 nm line was previously fitted with a convolution of a Lorentzian and a Gaussian profiles to determine the electron density. It is proposed here to use more elaborate theoretical profiles accounting for the Stark-Zeeman contributions in order to obtain more accurate plasma parameters especially for the high-resolution spectra in which both Zeeman and Stark features are visible. We present some preliminary comparisons with such spectra which were measured recently in LHD and discuss the possible improvement of the considered investigation technique once all the contributions to the line profile are effectively included. (author)

  3. Preliminary results from water content and density measurements of the backfill and buffer in the prototype repository at Aespoe HRL

    International Nuclear Information System (INIS)

    Johannesson, Lars-Erik; Grahm, Paer; Hagman, Patrik

    2012-01-01

    content and density. Preliminary results from the excavation are showing no evidence of piping and erosion in the backfill and the contact between the backfill and the tunnel surface was intact, i.e. no gaps between the tunnel wall and the filling were observed. Furthermore, the measurements of the water content and the density are indicating that the backfill was fully saturated, although the filling close to the roof had a higher water content compared to the central part of the tunnel resulting in a lower density. Samples were taken with the object of determining density and water content when removing the buffer (MX-80) in the two deposition holes. Samples were also taken for analysis of possible biological, chemical and mechanical changes in the buffer. The buffer was not expected to be water saturated in all parts. Furthermore, the water intake has occurred via the rock which means that density and water content was not expected to be axisymmetrical. In order to get a picture of the variation in density and water content of the buffer in the two deposition holes, an extensive sampling of the buffer was made. The examination was made in 8 radial directions in each of the 14 blocks. Most of the samples were taken by core drilling from the top of each of the bentonite blocks. Altogether more than 3500 determinations of water content and density were made on the buffer in each of the deposition holes. The preliminary analyses of the buffer are indicating that the buffer was not fully saturated and that the water uptake was not axisymmetric. An axial swelling of the buffer, especially the upper part of the buffer, causing decrease in density, was also observed. (authors)

  4. Development and preliminary validation of the 'Caring for Country' questionnaire: measurement of an Indigenous Australian health determinant

    Directory of Open Access Journals (Sweden)

    Gunthorpe Wendy

    2008-12-01

    Full Text Available Abstract Background 'Caring for Country' is defined as Indigenous participation in interrelated activities with the objective of promoting ecological and human health. Ecological services on Indigenous-owned lands are belatedly attracting some institutional investment. However, the health outcomes associated with Indigenous participation in 'caring for country' activities have never been investigated. The aims of this study were to pilot and validate a questionnaire measuring caring for country as an Indigenous health determinant and to relate it to an external reference, obesity. Methods Purposively sampled participants were 301 Indigenous adults aged 15 to 54 years, recruited during a cross-sectional program of preventive health checks in a remote Australian community. Questionnaire validation was undertaken with psychometric tests of internal consistency, reliability, exploratory factor analysis and confirmatory one-factor congeneric modelling. Accurate item weightings were derived from the model and used to create a single weighted composite score for caring for country. Multiple linear regression modelling was used to test associations between the caring for country score and body mass index adjusting for socio-demographic factors and health behaviours. Results The questionnaire demonstrated adequate internal consistency, test-retest validity and proxy-respondent validity. Exploratory factor analysis of the 'caring for country' items produced a single factor solution that was confirmed via one-factor congeneric modelling. A significant and substantial association between greater participation in caring for country activities and lower body mass index was demonstrated. Adjusting for socio-demographic factors and health behaviours, an inter-quartile range rise in caring for country scores was associated with 6.1 Kg and 5.3 Kg less body weight for non-pregnant women and men respectively. Conclusion This study indicates preliminary support for

  5. Spectroscopic observations of AG Dra

    International Nuclear Information System (INIS)

    Chang-Chun, H.

    1982-01-01

    During summer 1981, spectroscopic observations of AG Dra were performed at the Haute-Provence Observatory using the Marly spectrograph with a dispersion of 80 A mm -1 at the 120 cm telescope and using the Coude spectrograph of the 193 cm telescope with a dispersion of 40 A mm -1 . The actual outlook of the spectrum of AG Dra is very different from what it was in 1966 in the sense that only a few intense absorption lines remain, the heavy emission continuum masking the absorption spectrum, while on the 1966 plate, about 140 absorption lines have been measured. Numerous emission lines have been measured, most of them, present in 1981, could also be detected in 1966. They are due to H, HeI and HeII. (Auth.)

  6. Spectroscopic Studies on Complex Formation of U(VI)-thiosalicylate

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Wan Sik; Cho, Hye Ryun; Park, Kyoung Kyun; Jung, Euo Chang [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    The dynamic interaction between radionuclides and organic ligands is largely dependent on the composition of functional groups in a ligand chemical structure. Therefore, the structural mimics of natural ligands possessing specific functional groups, such as hydroxy, phenol, carboxyl, thiol and amine groups, have been studied to understand their influence on the migration of radionuclides including actinide species under geological groundwater conditions. In previous studies, we demonstrated that the fraction of hydrolyzed U(VI) species occurring in weak acidic solutions (pH {approx}4.5) is significantly influenced by the presence of salicylate (Sal) ligand due to the simultaneous participation of both phenol and carboxyl groups in the formation of U(VI)-complexes. Thiosalicylic acid (TSalH{sub 2}) is a good model compound for studying the effects of both carboxyl and thiol (-SH) groups. The fraction of di-anionic ligand form (TSal{sup 2-}) is higher at near neutral pH due to the lower pKa ({approx} 8) of the thiol group than the case of salicylic acid (pKa, {approx}13 for salicylic -OH), despite the structural similarity. In addition, the redox capability of the thiol group is expected to influence the reducible radiouclides and the chemical structures of natural ligands by creating cross-linkage (-S-S-) upon oxidation. The goal of the present study is to investigate aqueous U(VI)-TSal complexation equilibrium via laser-based spectroscopic techniques including time resolved laser-induced fluorescence spectroscopy (TRLFS). In this preliminary work, we report the results of spectroscopic studies using conventional UVVis absorbance and fluorescence (FL) measurement methods. The photo-stability of U(VI)-TSal complex or ligand itself upon exposure to a series of laser pulses is estimated by monitoring the change in their absorption bands. Additionally, TSal FL-quenching effect by U(VI) ions is discussed in comparison with that of Sal FL-quenching

  7. The passive oxide films growth on 316L stainless steel in borate buffer solution measured by real-time spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Haisong; Wang, Lu; Sun, Dongbai [National Center for Materials Service Safety (NCMS), University of Science and Technology Beijing, Beijing 100083 (China); Yu, Hongying, E-mail: hyyu@ustb.edu.cn [Institute of Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-10-01

    Highlights: • The optical properties of passive oxide films on 316L stainless steel were studied. • The thickness of the oxide films (1.5–2.6 nm) increased linearly with the potentials. • The growth of passive film followed high electric field ion conduction model. • Selective solubility of oxide induced compositional change of passive film. - Abstract: Passive film growth on 316L stainless steel was investigated in borate buffer electrolyte (pH = 9.1) by real-time spectroscopic ellipsometry (SE) and the composition was estimated by X-ray photoelectron spectroscopy (XPS). Anodic passivation of 316L SS was carried out in the potential range from 0 V{sub SCE} to 0.9 V{sub SCE}, after potentiostatic polarization for 1800s, the current density decayed from 10{sup −2} A cm{sup −2} to 10{sup −6} A cm{sup −2}. The passive film thickness was simulated from Frenel and Drude reflection equations, the average complex refractive index was assumed to be N = 2.3 − j0.445. The estimated thickness increased linearly with potential from 1.5 nm at 0 V to 2.6 nm at 0.8 V. The growth of passive film followed high electric field ion conduction model. The passive film mainly contained the oxide/hydroxide of iron and chromium. The selective solubility of oxide in passive film explained the change of iron and chromium content at different potentials. Few nickel and molybdenum also contributed to the passive film with a constant content.

  8. Spectroscopic characterization of galaxy clusters in RCS-1: spectroscopic confirmation, redshift accuracy, and dynamical mass-richness relation

    Science.gov (United States)

    Gilbank, David G.; Barrientos, L. Felipe; Ellingson, Erica; Blindert, Kris; Yee, H. K. C.; Anguita, T.; Gladders, M. D.; Hall, P. B.; Hertling, G.; Infante, L.; Yan, R.; Carrasco, M.; Garcia-Vergara, Cristina; Dawson, K. S.; Lidman, C.; Morokuma, T.

    2018-05-01

    We present follow-up spectroscopic observations of galaxy clusters from the first Red-sequence Cluster Survey (RCS-1). This work focuses on two samples, a lower redshift sample of ˜30 clusters ranging in redshift from z ˜ 0.2-0.6 observed with multiobject spectroscopy (MOS) on 4-6.5-m class telescopes and a z ˜ 1 sample of ˜10 clusters 8-m class telescope observations. We examine the detection efficiency and redshift accuracy of the now widely used red-sequence technique for selecting clusters via overdensities of red-sequence galaxies. Using both these data and extended samples including previously published RCS-1 spectroscopy and spectroscopic redshifts from SDSS, we find that the red-sequence redshift using simple two-filter cluster photometric redshifts is accurate to σz ≈ 0.035(1 + z) in RCS-1. This accuracy can potentially be improved with better survey photometric calibration. For the lower redshift sample, ˜5 per cent of clusters show some (minor) contamination from secondary systems with the same red-sequence intruding into the measurement aperture of the original cluster. At z ˜ 1, the rate rises to ˜20 per cent. Approximately ten per cent of projections are expected to be serious, where the two components contribute significant numbers of their red-sequence galaxies to another cluster. Finally, we present a preliminary study of the mass-richness calibration using velocity dispersions to probe the dynamical masses of the clusters. We find a relation broadly consistent with that seen in the local universe from the WINGS sample at z ˜ 0.05.

  9. Preliminary comparative assessment of PM10 hourly measurement results from new monitoring stations type using stochastic and exploratory methodology and models

    Science.gov (United States)

    Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł

    2018-01-01

    The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.

  10. Phosphorus-31 spectroscopic imaging of the human liver

    International Nuclear Information System (INIS)

    Biran, M.; Raffard, G.; Canioni, P.; Kien, P.

    1993-01-01

    During the last decade, progresses in the field of nuclear magnetic resonance spectroscopy (M.R.S.), have allowed the metabolic studies of complex biological systems. Since the coming out of whole body magnets, clinical applications are possible; they utilize magnetic field gradients coupled with selective pulse sequences. Study of the phosphorylated metabolism of human liver can be performed with sequences as ISIS, FROGS or 1D-CSI. But they present some disadvantages (for instance contamination by phosphocreatine from muscle). In the present work, we have studied the human liver in vivo by 31 P spectroscopic imaging. Several spectra could be acquired with only one acquisition. This study has needed the building of radiofrequency coils (surface coils), specially designed for liver observation (15 cm diameter 31 P coil and 19 cm diameter proton coil, both transmitter and receiver coils). Preliminary studies have been done on a phantom followed by in vivo measurements on healthy subject livers. We have obtained localized 31 P N.M.R. spectra corresponding to different voxels within the hepatic tissue. The conditions of acquisition of spectra and the problems related to the saturation of phosphorylated metabolite signals (in particular phosphodiesters) are discussed. (author). 5 figs., 15 refs

  11. Mini-DIAL system measurements coupled with multivariate data analysis to identify TIC and TIM simulants: preliminary absorption database analysis

    International Nuclear Information System (INIS)

    Gaudio, P; Malizia, A; Gelfusa, M; Poggi, L.A.; Martinelli, E.; Di Natale, C.; Bellecci, C.

    2017-01-01

    Nowadays Toxic Industrial Components (TICs) and Toxic Industrial Materials (TIMs) are one of the most dangerous and diffuse vehicle of contamination in urban and industrial areas. The academic world together with the industrial and military one are working on innovative solutions to monitor the diffusion in atmosphere of such pollutants. In this phase the most common commercial sensors are based on “point detection” technology but it is clear that such instruments cannot satisfy the needs of the smart cities. The new challenge is developing stand-off systems to continuously monitor the atmosphere. Quantum Electronics and Plasma Physics (QEP) research group has a long experience in laser system development and has built two demonstrators based on DIAL (Differential Absorption of Light) technology could be able to identify chemical agents in atmosphere. In this work the authors will present one of those DIAL system, the miniaturized one, together with the preliminary results of an experimental campaign conducted on TICs and TIMs simulants in cell with aim of use the absorption database for the further atmospheric an analysis using the same DIAL system. The experimental results are analysed with standard multivariate data analysis technique as Principal Component Analysis (PCA) to develop a classification model aimed at identifying organic chemical compound in atmosphere. The preliminary results of absorption coefficients of some chemical compound are shown together pre PCA analysis. (paper)

  12. Infrared Solar Spectroscopic Measurements of Free Tropospheric CO, C2H6, and HCN above Mauna Loa, Hawaii: Seasonal Variations and Evidence for Enhanced Emissions from the Southeast Asian Tropical Fires of 1997-1998

    Science.gov (United States)

    Rinsland, C. P.; Goldman, A.; Murcray, F. J.; Stephen, T. M.; Pougatchev, N. S.; Fishman, J.; David, S. J.; Blatherwick, R. D.; Novelli, P. C.; Jones, N. B.

    1999-01-01

    High spectral resolution (0.003 per cm) infrared solar absorption measurements of CO, C2H6, and HCN have been recorded at the Network for the Detection of Stratospheric Change station on Mauna Loa, Hawaii, (19.5N, 155.6W, altitude 3.4 km). The observations were obtained on over 250 days between August 1995 and February 1998. Column measurements are reported for the 3.4-16 km altitude region, which corresponds approximately to the free troposphere above the station. Average CO mixing ratios computed for this layer have been compared with flask sampling CO measurements obtained in situ at the station during the same time period. Both show asymmetrical seasonal cycles superimposed on significant variability. The first 2 years of observations exhibit a broad January-April maximum and a sharper CO minimum during late summer. The C2H6 and CO 3.4-16 km columns were highly correlated throughout the observing period with the C2H6/CO slope intermediate between higher and lower values derived from similar infrared spectroscopic measurements at 32'N and 45'S latitude, respectively. Variable enhancements in CO, C2H6, and particularly HCN were observed beginning in about September 1997. The maximum HCN free tropospheric monthly mean column observed in November 1997 corresponds to an average 3.4-16 km mixing ratio of 0.7 ppbv (1 ppbv = 10(exp -9) per unit volume), more than a factor of 3 above the background level. The HCN enhancements continued through the end of the observational series. Back-trajectory calculations suggest that the emissions originated at low northern latitudes in southeast Asia. Surface CO mixing ratios and the C2H6 tropospheric columns measured during the same time also showed anomalous autumn 1997 maxima. The intense and widespread tropical wild fires that burned during the strong El Nino warm phase of 1997- 1998 are the likely source of the elevated emission products.

  13. Errors in spectroscopic measurements of SO2 due to nonexponential absorption of laser radiation, with application to the remote monitoring of atmospheric pollutants

    International Nuclear Information System (INIS)

    Brassington, D.J.; Moncrieff, T.M.; Felton, R.C.; Jolliffe, B.W.; Marx, B.R.; Rowley, W.R.C.; Woods, P.T.

    1984-01-01

    Methods of measuring the concentration of atmospheric pollutants by laser absorption spectroscopy, such as differential absorption lidar (DIAL) and integrated long-path techniques, all rely on the validity of Beer's exponential absorption law. It is shown here that departures from this law occur if the probing laser has a bandwidth larger than the wavelength scale of structure in the absorption spectrum of the pollutant. A comprehensive experimental and theoretical treatment of the errors resulting from these departures is presented for the particular case of SO 2 monitoring at approx.300 nm. It is shown that the largest error occurs where the initial calibration measurement of absorption cross section is made at low pressure, in which case errors in excess of 5% in the cross section could occur for laser bandwidths >0.01 nm. Atmospheric measurements by DIAL or long-path methods are in most cases affected less, because pressure broadening smears the spectral structure, but when measuring high concentrations errors can exceed 5%

  14. Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach

    Science.gov (United States)

    Yong, WANG; Cong, LI; Jielin, SHI; Xingwei, WU; Hongbin, DING

    2017-11-01

    As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering (LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5 × 1019 m-3 to 7.1 × 1020 m-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison, an optical emission spectroscopy (OES) system was established as well. The results showed that the electron excitation temperature (configuration temperature) measured by OES is significantly higher than the electron temperature (kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium (LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.

  15. The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: measurement of the growth rate of structure from the anisotropic correlation function between redshift 0.8 and 2.2

    Science.gov (United States)

    Zarrouk, Pauline; Burtin, Etienne; Gil-Marín, Héctor; Ross, Ashley J.; Tojeiro, Rita; Pâris, Isabelle; Dawson, Kyle S.; Myers, Adam D.; Percival, Will J.; Chuang, Chia-Hsun; Zhao, Gong-Bo; Bautista, Julian; Comparat, Johan; González-Pérez, Violeta; Habib, Salman; Heitmann, Katrin; Hou, Jiamin; Laurent, Pierre; Le Goff, Jean-Marc; Prada, Francisco; Rodríguez-Torres, Sergio A.; Rossi, Graziano; Ruggeri, Rossana; Sánchez, Ariel G.; Schneider, Donald P.; Tinker, Jeremy L.; Wang, Yuting; Yèche, Christophe; Baumgarten, Falk; Brownstein, Joel R.; de la Torre, Sylvain; du Mas des Bourboux, Hélion; Kneib, Jean-Paul; Mariappan, Vivek; Palanque-Delabrouille, Nathalie; Peacock, John; Petitjean, Patrick; Seo, Hee-Jong; Zhao, Cheng

    2018-06-01

    We present the clustering measurements of quasars in configuration space based on the Data Release 14 (DR14) of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey (eBOSS). This data set includes 148 659 quasars spread over the redshift range 0.8 ≤ z ≤ 2.2 and spanning 2112.9 deg2. We use the Convolution Lagrangian Perturbation Theory approach with a Gaussian Streaming model for the redshift space distortions of the correlation function and demonstrate its applicability for dark matter haloes hosting eBOSS quasar tracers. At the effective redshift zeff = 1.52, we measure the linear growth rate of structure fσ8(zeff) = 0.426 ± 0.077, the expansion rate H(z_eff)= 159^{+12}_{-13}(rs^fid/r_s) {{}km s}^{-1} Mpc^{-1}, and the angular diameter distance DA(z_eff)=1850^{+90}_{-115} (r_s/rs^fid) {}Mpc, where rs is the sound horizon at the end of the baryon drag epoch and rs^fid is its value in the fiducial cosmology. The quoted uncertainties include both systematic and statistical contributions. The results on the evolution of distances are consistent with the predictions of flat Λ-cold dark matter cosmology with Planck parameters, and the measurement of fσ8 extends the validity of General Relativity to higher redshifts (z > 1). This paper is released with companion papers using the same sample. The results on the cosmological parameters of the studies are found to be in very good agreement, providing clear evidence of the complementarity and of the robustness of the first full-shape clustering measurements with the eBOSS DR14 quasar sample.

  16. High-frequency conductivity of optically excited charge carriers in hydrogenated nanocrystalline silicon investigated by spectroscopic femtosecond pump–probe reflectivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    He, Wei [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom); Yurkevich, Igor V. [Aston University, Nonlinearity and Complexity Research Group, Birmingham B4 7ET (United Kingdom); Zakar, Ammar [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom); Kaplan, Andrey, E-mail: a.kaplan.1@bham.ac.uk [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom)

    2015-10-01

    We report an investigation into the high-frequency conductivity of optically excited charge carriers far from equilibrium with the lattice. The investigated samples consist of hydrogenated nanocrystalline silicon films grown on a thin film of silicon oxide on top of a silicon substrate. For the investigation, we used an optical femtosecond pump–probe setup to measure the reflectance change of a probe beam. The pump beam ranged between 580 and 820 nm, whereas the probe wavelength spanned 770 to 810 nm. The pump fluence was fixed at 0.6 mJ/cm{sup 2}. We show that at a fixed delay time of 300 fs, the conductivity of the excited electron–hole plasma is described well by a classical conductivity model of a hot charge carrier gas found at Maxwell–Boltzmann distribution, while Fermi–Dirac statics is not suitable. This is corroborated by values retrieved from pump–probe reflectance measurements of the conductivity and its dependence on the excitation wavelength and carrier temperature. The conductivity decreases monotonically as a function of the excitation wavelength, as expected for a nondegenerate charge carrier gas. - Highlights: • We study high‐frequency conductivity of excited hydrogenated nanocrystalline silicon. • Reflectance change was measured as a function of pump and probe wavelength. • Maxwell–Boltzmann transport theory was used to retrieve the conductivity. • The conductivity decreases monotonically as a function of the pump wavelength.

  17. Thermal, conductivity, NMR, and Raman spectroscopic measurements and phase diagram of the Cs2S2O7-CsHSO4 system

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Hama, Hind; Lapina, Olga

    2003-01-01

    The conductivity of the binary system CS2S2O7-CsHSO4 has been measured at 20 different molten compositions in the full composition range and in the temperature range 430-750 K. From the obtained liquidus-solidus phase transition temperatures, the phase diagram has been constructed. It is of the s......The conductivity of the binary system CS2S2O7-CsHSO4 has been measured at 20 different molten compositions in the full composition range and in the temperature range 430-750 K. From the obtained liquidus-solidus phase transition temperatures, the phase diagram has been constructed...... from the NMR measurements on CsHSO4, CS2S2O7, and Cs2S2O7-CsHSO4 mixtures. For 11 selected compositions covering the entire composition range of the CS2S2O7-CsHSO4 binary system, the conductivity of the molten state has been expressed by equations of the form k(X) = A(X) + B(X)(T - T-m) + C(X)(T - T...

  18. Spectroscopic diagnostics of industrial plasmas

    International Nuclear Information System (INIS)

    Joshi, N.K.

    2004-01-01

    Plasmas play key role in modern industry and are being used for processing micro electronic circuits to the destruction of toxic waste. Characterization of industrial plasmas which includes both 'thermal plasmas' and non-equilibrium plasmas or 'cold plasmas' in industrial environment offers quite a challenge. Numerous diagnostic techniques have been developed for the measurement of these partially ionized plasma and/or particulate parameters. The 'simple' non-invasive spectroscopic methods for characterization of industrial plasmas will be discussed in detail in this paper. The excitation temperature in thermal (DC/RF) plasma jets has been determined using atomic Boltzmann technique. The central axis temperature of thermal plasma jets in a spray torch can be determined using modified atomic Boltzmann technique with out using Abel inversion. The Stark broadening of H β and Ar-I (430 nm) lines have been used to determine the electron number density in thermal plasma jets. In low-pressure non-equilibrium argon plasma, electron temperature has been measured using the Corona model from the ratio of line intensities of atomic and ionic transitions. (author)

  19. Real-time monitoring of longitudinal electron bunch parameters by intensity-integrated and spectroscopic measurements of single coherent THz pulses

    International Nuclear Information System (INIS)

    Wesch, Stephan

    2012-12-01

    High-gain free-electron lasers (FELs) generate intense and monochromatic photon pulses with few tens of femtosecond duration. For this purpose, electron beams are accelerated to relativistic energies and shrunk longitudinally down to micrometer size.The diagnosis of theses compressed electron bunches is a challenge especially for MHz bunch repetition rates as provided by the FEL FLASH in Hamburg. In this thesis, coherently emitted THz radiation of single electron bunches were investigated, on which the longitudinal structure is imprinted. Two instruments were used: First, the FLASH bunch compression monitors, relying on the integrated intensity measurement of diffraction radiation, were modified to determine the overall length of every bunch behind the two bunch compressors (BC). A model was developed showing that their response is independent of the exact bunch shape for lengths below 200 μm (rms). This could experimentally be verified in the range between 50 and 190 μm within 7% accuracy for themonitor behind the last BC by comparison with measurements with the transverse deflecting structure (TDS). Second, a single-shot spectrometer with five staged reflective blazed gratings has been designed, build and commissioned. With its two grating sets, the wavelength ranges from 5.5 to 44 μm and 45 to 440 μm can be simultaneously detected by 118 fast pyroelectric elements. Measurements based on transition radiation spectra were compared with profiles recorded by the TDS.The shape of the spectra as well as the reconstructed temporal profiles (using the Kramers-Kronig relation for phase retrieval) are in excellent agreement. For bunches with a charge of 50 pC, bunch lengths down to 5 μm (fhwm) could be detected.

  20. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473 K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements

    Science.gov (United States)

    Lu, Wanjun; Guo, Huirong; Chou, I.-Ming; Burruss, R.C.; Li, Lanlan

    2013-01-01

    Accurate values of diffusion coefficients for carbon dioxide in water and brine at reservoir conditions are essential to our understanding of transport behavior of carbon dioxide in subsurface pore space. However, the experimental data are limited to conditions at low temperatures and pressures. In this study, diffusive transfer of carbon dioxide in water at pressures up to 45 MPa and temperatures from 268 to 473 K was observed within an optical capillary cell via time-dependent Raman spectroscopy. Diffusion coefficients were estimated by the least-squares method for the measured variations in carbon dioxide concentration in the cell at various sample positions and time. At the constant pressure of 20 MPa, the measured diffusion coefficients of carbon dioxide in water increase with increasing temperature from 268 to 473 K. The relationship between diffusion coefficient of carbon dioxide in water [D(CO2) in m2/s] and temperature (T in K) was derived with Speedy–Angell power-law approach as: D(CO2)=D0[T/Ts-1]m where D0 = 13.942 × 10−9 m2/s, Ts = 227.0 K, and m = 1.7094. At constant temperature, diffusion coefficients of carbon dioxide in water decrease with pressure increase. However, this pressure effect is rather small (within a few percent).

  1. Dual-channel red/blue fluorescence dosimetry with broadband reflectance spectroscopic correction measures protoporphyrin IX production during photodynamic therapy of actinic keratosis

    Science.gov (United States)

    Kanick, Stephen Chad; Davis, Scott C.; Zhao, Yan; Hasan, Tayyaba; Maytin, Edward V.; Pogue, Brian W.; Chapman, M. Shane

    2014-07-01

    Dosimetry for aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) photodynamic therapy of actinic keratosis was examined with an optimized fluorescence dosimeter to measure PpIX during treatment. While insufficient PpIX generation may be an indicator of incomplete response, there exists no standardized method to quantitate PpIX production at depths in the skin during clinical treatments. In this study, a spectrometer-based point probe dosimeter system was used to sample PpIX fluorescence from superficial (blue wavelength excitation) and deeper (red wavelength excitation) tissue layers. Broadband white light spectroscopy (WLS) was used to monitor aspects of vascular physiology and inform a correction of fluorescence for the background optical properties. Measurements in tissue phantoms showed accurate recovery of blood volume fraction and reduced scattering coefficient from WLS, and a linear response of PpIX fluorescence versus concentration down to 1.95 and 250 nM for blue and red excitations, respectively. A pilot clinical study of 19 patients receiving 1-h ALA incubation before treatment showed high intrinsic variance in PpIX fluorescence with a standard deviation/mean ratio of >0.9. PpIX fluorescence was significantly higher in patients reporting higher pain levels on a visual analog scale. These pilot data suggest that patient-specific PpIX quantitation may predict outcome response.

  2. The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: structure growth rate measurement from the anisotropic quasar power spectrum in the redshift range 0.8 < z < 2.2

    Science.gov (United States)

    Gil-Marín, Héctor; Guy, Julien; Zarrouk, Pauline; Burtin, Etienne; Chuang, Chia-Hsun; Percival, Will J.; Ross, Ashley J.; Ruggeri, Rossana; Tojerio, Rita; Zhao, Gong-Bo; Wang, Yuting; Bautista, Julian; Hou, Jiamin; Sánchez, Ariel G.; Pâris, Isabelle; Baumgarten, Falk; Brownstein, Joel R.; Dawson, Kyle S.; Eftekharzadeh, Sarah; González-Pérez, Violeta; Habib, Salman; Heitmann, Katrin; Myers, Adam D.; Rossi, Graziano; Schneider, Donald P.; Seo, Hee-Jong; Tinker, Jeremy L.; Zhao, Cheng

    2018-06-01

    We analyse the clustering of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey Data Release 14 quasar sample (DR14Q). We measure the redshift space distortions using the power-spectrum monopole, quadrupole, and hexadecapole inferred from 148 659 quasars between redshifts 0.8 and 2.2, covering a total sky footprint of 2112.9 deg2. We constrain the logarithmic growth of structure times the amplitude of dark matter density fluctuations, fσ8, and the Alcock-Paczynski dilation scales that allow constraints to be placed on the angular diameter distance DA(z) and the Hubble H(z) parameter. At the effective redshift of zeff = 1.52, fσ8(zeff) = 0.420 ± 0.076, H(z_eff)=[162± 12] (r_s^fid/r_s) {km s}^{-1} Mpc^{-1}, and D_A(z_eff)=[1.85± 0.11]× 10^3 (r_s/r_s^fid) Mpc, where rs is the comoving sound horizon at the baryon drag epoch and the superscript `fid' stands for its fiducial value. The errors take into account the full error budget, including systematics and statistical contributions. These results are in full agreement with the current Λ-Cold Dark Matter cosmological model inferred from Planck measurements. Finally, we compare our measurements with other eBOSS companion papers and find excellent agreement, demonstrating the consistency and complementarity of the different methods used for analysing the data.

  3. Raman spectroscopic measurements of CO2 density: Experimental calibration with high-pressure optical cell (HPOC) and fused silica capillary capsule (FSCC) with application to fluid inclusion observations

    Science.gov (United States)

    Wang, X.; Chou, I-Ming; Hu, W.; Burruss, Robert; Sun, Q.; Song, Y.

    2011-01-01

    Raman spectroscopy is a powerful method for the determination of CO2 densities in fluid inclusions, especially for those with small size and/or low fluid density. The relationship between CO2 Fermi diad split (Δ, cm−1) and CO2 density (ρ, g/cm3) has been documented by several previous studies. However, significant discrepancies exist among these studies mainly because of inconsistent calibration procedures and lack of measurements for CO2fluids having densities between 0.21 and 0.75 g/cm3, where liquid and vapor phases coexist near room temperature.In this study, a high-pressure optical cell and fused silica capillary capsules were used to prepare pure CO2 samples with densities between 0.0472 and 1.0060 g/cm3. The measured CO2 Fermi diad splits were calibrated with two well established Raman bands of benzonitrile at 1192.6 and 1598.9 cm−1. The relationship between the CO2 Fermi diad split and density can be represented by: ρ = 47513.64243 − 1374.824414 × Δ + 13.25586152 × Δ2 − 0.04258891551 × Δ3(r2 = 0.99835, σ = 0.0253 g/cm3), and this relationship was tested by synthetic fluid inclusions and natural CO2-rich fluid inclusions. The effects of temperature and the presence of H2O and CH4 on this relationship were also examined.

  4. Association of low non-invasive near-infrared spectroscopic measurements during initial trauma resuscitation with future development of multiple organ dysfunction.

    Science.gov (United States)

    Nicks, Bret A; Campons, Kevin M; Bozeman, William P

    2015-01-01

    Near-infrared spectroscopy (NIRS) non-invasively monitors muscle tissue oxygen saturation (StO2). It may provide a continuous noninvasive measurement to identify occult hypoperfusion, guide resuscitation, and predict the development of multiple organ dysfunction (MOD) after severe trauma. We evaluated the correlation between initial StO2 and the development of MOD in multi-trauma patients. Patients presenting to our urban, academic, Level I Trauma Center/Emergency Department and meeting standardized trauma-team activation criteria were enrolled in this prospective trial. NIRS monitoring was initiated immediately on arrival with collection of StO2 at the thenar eminence and continued up to 24 hours for those admitted to the Trauma Intensive Care Unit (TICU). Standardized resuscitation laboratory measures and clinical evaluation tools were collected. The primary outcome was the association between initial StO2 and the development of MOD within the first 24 hours based on a MOD score of 6 or greater. Descriptive statistical analyses were performed; numeric means, multivariate regression and rank sum comparisons were utilized. Clinicians were blinded from the StO2 values. Over a 14 month period, 78 patients were enrolled. Mean age was 40.9 years (SD 18.2), 84.4% were male, 76.9% had a blunt trauma mechanism and mean injury severity score (ISS) was 18.5 (SD 12.9). Of the 78 patients, 26 (33.3%) developed MOD within the first 24 hours. The MOD patients had mean initial StO2 values of 53.3 (SD 10.3), significantly lower than those of non-MOD patients 61.1 (SD 10.0); P=0.002. The mean ISS among MOD patients was 29.9 (SD 11.5), significantly higher than that of non-MODS patients, 12.1 (SD 9.1) (P<0.0001). The mean shock index (SI) among MOD patients was 0.92 (SD 0.28), also significantly higher than that of non-MODS patients, 0.73 (SD 0.19) (P=0.0007). Lactate values were not significantly different between groups. Non-invasive, continuous StO2 near-infrared spectroscopy

  5. Laser spectroscopic measurements of fine structure changing cross sections of alkali earth ions in collisions with molecular hydrogen (H2, D2)

    International Nuclear Information System (INIS)

    Moriwaki, Yoshiki; Matsuo, Yukari; Fukuyama, Yoshimitsu; Morita, Norio

    2006-01-01

    Production of alkali earth ions (Ca + , Sr + and Ba + ) by means of a laser ablation technique and measurement of their laser-induced fluorescence, cross sections of collision-induced transitions between the np 2 P J fine structure levels (n= 4, 5 and 6 for Ca + , Sr + and Ba + , respectively) due to collisions with hydrogen molecules at room temperature (298 K) has been performed. The cross sections thus determined for the collisions with H 2 and D 2 are σ(Ca + : 4p 2 P 3/2 → 4p 2 P 1/2 ) = 20.5 ± 0.5, 27.1 ± 1.3 A 2 , σ(Ca + : 4p 2 P 1/2 → 4p 2 P 3/2 ) = 13.2 ± 0.6, 18.7 ± 0.8 A 2 , σ(Sr + : 5p 2 P 3/2 → 5p 2 P 1/2 ) = 22.7 ± 0.4, 18.0 ± 0.4 A 2 and σ(Ba + : 6p 2 P 3/2 → 6p 2 P 1/2 ) 10.4 ± 0.1, 3.4 ± 0.2 A 2 , respectively

  6. Simultaneous small-angle neutron scattering and Fourier transform infrared spectroscopic measurements on cocrystals of syndiotactic polystyrene with polyethylene glycol dimethyl ethers.

    Science.gov (United States)

    Kaneko, Fumitoshi; Seto, Naoki; Sato, Shuma; Radulescu, Aurel; Schiavone, Maria Maddalena; Allgaier, Jürgen; Ute, Koichi

    2016-10-01

    Syndiotactic polystyrene (sPS) is a crystalline polymer which has a unique property; it is able to form cocrystals with a wide range of chemical compounds, in which the guest molecules are confined in the vacancies of the host sPS crystalline region. Recently, it has been found that even polyethylene glycol oligomers with a molecular weight of more than several hundreds can be introduced into the sPS crystalline region. It is quite important to know how such a long-chain molecule is stored in the host sPS lattice. To tackle this issue, a new simultaneous measurement method combing small-angle neutron scattering and Fourier transform infrared spectroscopy (SANS/FTIR), which has been recently developed by the authors, was applied to an sPS cocrystal with polyethylene glycol dimethyl ether with a molecular weight of 500 (PEGDME500). The temperature-dependent changes of the SANS profile and FTIR spectrum were followed from room temperature up to 413 K for a one-dimensionally oriented SANS/PEGDME500 cocrystal sample. The intensity of the reflections due to the stacking of crystalline lamellae showed a significant temperature dependence. The two-dimensional pattern in the high Q region of SANS also changed depending on temperature. The combined information obtained by SANS and FTIR suggested that PEGDME500 molecules are distributed in both the crystalline and amorphous regions in the low-temperature region close to room temperature, but they are predominantly included in the amorphous region in the high-temperature region. It was also suggested by the two-dimensional SANS profile that PEGDME500 molecules in the crystalline region have an elongated structure along the thickness direction of the crystalline lamellae.

  7. Nuclear data for geophysical spectroscopic logging

    International Nuclear Information System (INIS)

    Schweitzer, J.S.; Hertzog, R.C.; Soran, P.D.

    1987-01-01

    Nuclear geochemical analysis requires the quantitative measurement of elemental concentrations of trace elements, as well as major elements in widely varying concentrations. This requirement places extreme demands on the quality of the spectroscopic measurements, data rates, and relating observed γ-ray intensities to the original elemental concentration. The relationship between γ-ray intensities and elemental concentration is critically dependent on the specific reaction cross sections and their uncertainties. The elements of highest priority for subsurface geochemical analysis are considered with respect to the importance of competing reactions and the neutron energy regions that are most significant. (author)

  8. Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

    Science.gov (United States)

    Saunders, M B; Gulabivala, K; Holt, R; Kahan, R S

    2000-05-01

    The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8-9 roots on periapical radiographs of single- and multirooted teeth, with and without previous root canal therapy and 3-4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra-observer agreement was tested by asking the students to re-examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter-observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8-9 different roots from the pool of radiographs. A further assessment of inter-observer variation was made by comparing these observations with the Gold Standard. Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra- and inter-observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra-observer recordings showed 'good' or 'very good' Kappa agreement, but only three out of 25 inter-observer observations achieved 'good' or 'very good' values. Inter-observer variation was improved following the revision session with 16 out of 25 observations achieving 'good' or 'very good' Kappa agreement. Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to

  9. Borehole radar measurements performed on preliminary investigation areas in Finland for final disposal of spent nuclear fuel

    International Nuclear Information System (INIS)

    Carlsten, S.

    1991-05-01

    Borehole radar measurements with the RAMAC system have been performed in 24 boreholes distributed between the investigation areas Kuhmo Romuvaara, Hyrynsalmi Veitsivaara, Konginkangas Kivetty, Sievi Syyry, and Eurajoki Olkiluoto. The purpose of the borehole radar measurement program has been to investigate the bedrock in the vicinity of the boreholes in order to obtain information about geometry and extent of fracture zones, lithological contacts and other structures. The measurements have been performed as singlehole radar reflection measurements and Vertical Radar Profiling (VRP) measurements, using antennas with 22 MHz frequency range in both configurations. The total measured length in the singlehole radar reflection mode is 13304 meter and in the VRP mode 9200 meter. The VRP measurements are not presented in the report. Radar data from the singlehole reflection measurements are presented as grey scale radar maps after digital filtering with a bandpass filter and a moving average filter. Interpreted zones from the singlehole radar measurements are presented in tables for each borehole. It has been possible to study structures at distances of more than 110 meter from the borehole

  10. Brief Report: Preliminary Evaluation of the Theory of Mind Inventory and Its Relationship to Measures of Social Skills

    Science.gov (United States)

    Lerner, Matthew D.; Hutchins, Tiffany L.; Prelock, Patricia A.

    2011-01-01

    This study presents updated information on a parent-report measure of Theory of Mind (ToM), formerly called the Perception of Children's Theory of Mind Measure (Hutchins et al., "J Autism Dev Disord" 38:143-155, 2008), renamed the Theory of Mind Inventory (ToMI), for use with parents of children with autism spectrum disorder (ASD). This study…

  11. Monitoring the Evolution and Benefits of Responsible Research and Innovation (MoRRI) – a preliminary framework for measuring RRI dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Mejlgaard, N.; Buehrer, S.; Griessler, E.; Lindner, R.; Maroulis, N.; Meijer, I.; Peter, V.; Rafols, I.; Ravn, T.; Stilgoe, J.; Tsipouri, L.; Woolley, R.; Wroblewski, A.

    2016-07-01

    European efforts to 'mainstream' the notion of Responsible Research and Innovation (RRI) is challenged by a lack of organisational and individual incentives, but also by absense of relevant measures of RRI. The European Commission has launched a study with the aim of developing indicators capturing the evolution and benefits of RRI across Europe. This paper presents the preliminary set of indicators identified by the project consortium. In recent years, the notion of Responsible Research and Innovation (RRI) has emerged in European policy making. From the perspective of the ‘Science with and for Society’ (SwafS) scheme of the European Commission (EC), the purpose of promoting RRI is “to build effective cooperation between science and society, to recruit new talent for science and to pair scientific excellence with social awareness and responsibility” (EC, 2016). (Author)

  12. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    International Nuclear Information System (INIS)

    Stratton, B.C.; Bitter, M.; Hill, K.W.; Hillis, D.L.; Hogan, J.T.

    2007-01-01

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  13. Passive Spectroscopic Diagnostics for Magnetically-confined Fusion Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, B. C.; Biter, M.; Hill, K. W.; Hillis, D. L.; Hogan, J. T.

    2007-07-18

    Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically-confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. This paper reviews spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed 'passive' spectroscopic diagnostics to distinguish them from 'active' spectroscopic diagnostics involving injected particle and laser beams. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

  14. Preliminary Findings from the One-Year Electric Field Study in the North Slope of Alaska (OYES-NSA), Atmospheric Radiation Measurement (ARM) Field Campaign

    Science.gov (United States)

    Lavigne, T.; Liu, C.

    2017-12-01

    Previous studies focusing on the comparison of the measured electric field to the physical properties of global electrified clouds have been conducted almost exclusively in the Southern Hemisphere. The One-Year Electric Field Study-North Slope of Alaska (OYES-NSA) aims to establish a long-running collection of this valuable electric field data in the Northern Hemisphere. Presented here is the six-month preliminary data and results of the OYES-NSA Atmospheric Radiation Mission (ARM) field campaign. The local electric field measured in Barrow, Alaska using two CS110 reciprocating shutter field meters, has been compared to simultaneous measurements from the ARM Ka-Band zenith radar, to better understand the influence and contribution of different types of clouds on the local electric field. The fair-weather electric field measured in Barrow has also been analyzed and compared to the climatology of electric field at Vostok Station, Antarctica. The combination of the electric field dataset in the Northern Hemisphere, alongside the local Ka cloud radar, global Precipitation Feature (PF) database, and quasi-global lightning activity (55oN-55oS), allows for advances in the physical understanding of the local electric field, as well as the Global Electric Circuit (GEC).

  15. A Preliminary Direct Measurement of the Parity-Violating Coupling of the Z{sup 0} to Strange Quarks, A{sub s}

    Energy Technology Data Exchange (ETDEWEB)

    Muller, David

    1999-07-09

    We present an updated direct measurement of the parity-violating coupling of the Z{sup 0} to strange quarks, A{sub s}, derived from the full SLD data sample of approximately 550,000 hadronic decays of Z{sup 0} bosons produced with a polarized electron beam and recorded by the SLD experiment at SLAC between 1993 and 1998. Z{sup 0} {r_arrow} s{bar s} events are tagged by the presence in each event hemisphere of a high-momentum K{sup {+-}}, K{sub s} or {Lambda}{sup 0}/{bar {Lambda}}{sup 0} identified using the Cherenkov Ring Imaging Detector and/or a mass tag. The CCD vertex detector is used to suppress the background from heavy-flavor events. The strangeness of the tagged particle is used to sign the event thrust axis in the direction of the initial s quark. The coupling A{sub s} is obtained directly from a measurement of the left-right-forward-backward production asymmetry in polar angle of the tagged s quark. The background from u{bar u} and d{bar d} events is measured from the data, as is the analyzing power of the method for s{bar s} events. We measure: A{sub s} = 0.85 {+-} 0.06(stat.) {+-} 0.07(syst.)(preliminary).

  16. Spectroscopic technique for measuring atmospheric CO2

    International Nuclear Information System (INIS)

    Stokes, G.M.; Stokes, R.A.

    1979-01-01

    As part of a continuing effort to identify areas in which astronomical techniques and data may be profitably applied to atmospheric problems, both new and archival solar spectra have been collected to prepare for an analysis of their use for studying the changes of the atmospheric CO 2 burden. This analysis has resulted in the initiation of an observing program using the Fourier Transform Spectrometer (FTS) of the McMath Solar Telescope at Kitt Peak National Observatory (KPNO). This program is generating spectra, the quality of which should not only aid the archival CO 2 study but also lead to analyses of other trace gases

  17. A preliminary layout and PIC simulations of the time resolved beam energy spectrum measurement for DRAGON-I

    International Nuclear Information System (INIS)

    Liao Shuqing; Zhang Kaizhi; Shi Jingshui

    2010-01-01

    The time resolved beam energy spectrum for DRAGON-I can be measured with a new method which is named RBS (Rotating Beam in Solenoid). The beam energy spectrum is determined by measuring the beam rotation angle and its expansion width at the exit of DRAGON-I. The rotation beam is shaped by a slit at the exit of DRAGON-I, then rotated in the magnetic field of the solenoids and the resulted beamlet is measured by the Cherenkov screen. The beam motion in the solenoids is simulated by PARMELA and the relationships between the beam rotation angle's expansion width and the beam energy spread, emittance are discussed. The measurement error is also discussed in this paper. (authors)

  18. Preliminary evaluation of a method using an FID (flame ionization detector) for measurement of methanol in auto emissions. Final report

    International Nuclear Information System (INIS)

    Gabele, P.A.; Ray, W.D.; Duncan, J.; Burton, C.

    1987-09-01

    This report evaluates a simplified technique for estimating methanol emission rates in auto exhaust. The technique, referred to as the FID Bubbled Method or FBM, is based in principle on the fact that, while hydrocarbons are not readily absorbed in water, methanol is. Hence, by using a heated flame ionization detector to measure the organic mass in samples before and after bubbling them in water, the quantity of methanol originally present can be estimated by taking the difference between the measurements. Evaluation of the method was done by comparing methanol measurements using the FBM with measurements made using an established reference method. Results showed poor to fair agreement between the two methods. The FBM appeared better at estimating methanol emission rates from evaporative tests than from exhaust tests and also exhibited better accuracy for samples containing higher levels of methanol

  19. Preliminary results of the average glandular dose to the breast with TLDS measure is computed as the conversion factors

    International Nuclear Information System (INIS)

    Sardo, Luiz T.L.; Almeida, Claudio D.; Coutinho, Celia M.C.

    2013-01-01

    At mammography exams there is a risk of a breast cancer induced from the absorbed dose by the glandular tissue. According to the National Institute of Cancer, INCA, breast cancer is the second type most frequent in the world and the most common among women, therefore the necessity of monitoring the mean glandular dose, D G . Measuring methods of D G were established by some authors. Among the established methods the method of Dance is one of the most known. In this study was utilized a measurement method realized with TL dosimeters inserted in a breast tissue equivalent phantom, BTE, with 46% of glandularity and exposed using Mo/Mo and Mo/Rh target/filter combination and 28kV. To ensure this measurement method the results were compared with a calculation method, used by Dance, of D G from the measurement of incident air kerma, K i , and conversion factors to consider mainly the beam quality, the compressed thickness and the glandularity of the breast. The results of the comparison of the D G measurement with the obtained dose by the method of Dance demonstrated that for the thickness of 4.0 and 6.0 cm the doses were consistent. For the thickness of 5.0 cm the difference was higher, indicating that the glandularity may influence, suggesting further investigation. (author)

  20. Measuring Changes in Social Communication Behaviors: Preliminary Development of the Brief Observation of Social Communication Change (BOSCC).

    Science.gov (United States)

    Grzadzinski, Rebecca; Carr, Themba; Colombi, Costanza; McGuire, Kelly; Dufek, Sarah; Pickles, Andrew; Lord, Catherine

    2016-07-01

    Psychometric properties and initial validity of the Brief Observation of Social Communication Change (BOSCC), a measure of treatment-response for social-communication behaviors, are described. The BOSCC coding scheme is applied to 177 video observations of 56 young children with ASD and minimal language abilities. The BOSCC has high to excellent inter-rater and test-retest reliability and shows convergent validity with measures of language and communication skills. The BOSCC Core total demonstrates statistically significant amounts of change over time compared to a no change alternative while the ADOS CSS over the same period of time did not. This work is a first step in the development of a novel outcome measure for social-communication behaviors with applications to clinical trials and longitudinal studies.

  1. Spectroscopic study of low-lying 16N levels

    International Nuclear Information System (INIS)

    Bardayan, Daniel W.; O'Malley, Patrick; Blackmon, Jeff C.; Chae, K.Y.; Chipps, K.; Cizewski, J.A.; Hatarik, Robert; Jones, K.L.; Kozub, R. L.; Matei, Catalin; Moazen, Brian; Nesaraja, Caroline D.; Pain, Steven D.; Paulauskas, Stanley; Peters, W.A.; Pittman, S.T.; Schmitt, Kyle; Shriner, J.F. Jr.; Smith, Michael Scott

    2008-01-01

    The magnitude of the 15N(n,gamma)16N reaction rate in asymptotic giant branch stars depends directly on the neutron spectroscopic factors of low-lying 16N levels. A new study of the 15N(d,p)16N reaction is reported populating the ground and first three excited states in 16N. The measured spectroscopic factors are near unity as expected from shell model calculations, resolving a long-standing discrepancy with earlier measurements that had never been confirmed or understood. Updated 15N(n,gamma)16N reaction rates are presented

  2. Innovation activity among nurses: The translation and preliminary validation of the Bricolage Measure – a mixed-method study

    DEFF Research Database (Denmark)

    Krontoft, Anna; Fuglsang, Lars; Kronborg, Hanne

    2018-01-01

    in healthcare. The aim of this study was therefore to provide an instrument for measuring bricolage activity among nurses, to test the measure and learn about the spread of bricolage in nursing in Denmark. We used a mixed- method design including a translation–back translation, a pre-test and a pilot test......Qualitatively, research has demonstrated the existence of bricolage among healthcare staff, i.e. solving problems on the spot by resources at hand, and its potential to lead to innovation. However, we know little about the spread of bricolage activity and its potential role for innovation...

  3. Spectroscopic analysis of optoelectronic semiconductors

    CERN Document Server

    Jimenez, Juan

    2016-01-01

    This book deals with standard spectroscopic techniques which can be used to analyze semiconductor samples or devices, in both, bulk, micrometer and submicrometer scale. The book aims helping experimental physicists and engineers to choose the right analytical spectroscopic technique in order to get specific information about their specific demands. For this purpose, the techniques including technical details such as apparatus and probed sample region are described. More important, also the expected outcome from experiments is provided. This involves also the link to theory, that is not subject of this book, and the link to current experimental results in the literature which are presented in a review-like style. Many special spectroscopic techniques are introduced and their relationship to the standard techniques is revealed. Thus the book works also as a type of guide or reference book for people researching in optical spectroscopy of semiconductors.

  4. Preliminary measurement of the drag force on a porous cylinder with fluid evolution under conditions relevant to pulverised-fuel combustion

    Energy Technology Data Exchange (ETDEWEB)

    Dijan Supramono; Graham J. Nathan; Peter J. Ashman; Peter J. Mullinger [University of Adelaide, Adelaide, SA (Australia). Cooperative Research Centre for Clean Power from Lignite, Schools of Chemical Engineering and Mechanical Engineering

    2003-07-01

    The trajectories of the particles in pulverised coal combustion systems determine their residence times and reaction environments, and hence coal burnout and flame length. The trajectories, in turn, depend upon the drag coefficient of the particle. The effect of the evolution of fluid from the surface of the particle on this coefficient has never been measured before, particularly at the low particle Reynolds numbers that apply during coal combustion. Therefore mathematical models must rely on assumed sphere drag coefficients, which do not account for the effect of fluid evolving from the surface. A technique of using a porous cylinder mounted on a pendulum, instead of a sphere, through which fluid can be forced to evolve, simulating fluid evolution in coal devolatilisation and char burning, is used. The pendulum is capable of measuring drag forces of the order of 10-5 to 10-6 Newton, at Reynolds numbers similar to that experienced by coal particles. This paper presents preliminary measurements of drag force at relevant conditions. The working fluid is water in the first instance, although it will be extended to diluted glycerine in the future. The cross flow is provided by a water tunnel and the ejected fluid is induced by a separate pump. Both the Reynolds number and the ratio of evolution velocity to free-stream velocity are chosen to span conditions relevant to pulverised coal combustion. 16 refs., 5 figs., 2 tabs.

  5. Development and preliminary validation of a measure of social inclusion for use in people with mental health problems: the SInQUE.

    Science.gov (United States)

    Mezey, Gillian; White, Sarah; Thachil, Ajoy; Berg, Rachel; Kallumparam, Sen; Nasiruddin, Omar; Wright, Christine; Killaspy, Helen

    2013-08-01

    Social exclusion can be both a cause and a consequence of mental health problems. Socially inclusive practice by mental health professionals can mitigate against the stigmatizing and excluding effects of severe mental illness. To develop and test the validity of a measure of social inclusion for individuals with severe mental illness - the Social Inclusion Questionnaire User Experience (SInQUE). The domains of the SInQUE were chosen to reflect the domains of social inclusion identified in the Poverty and Social Exclusion Survey. Patients with severe mental illness were recruited from rehabilitation, general and forensic psychiatric services and were asked to complete the questionnaire in an individual interview with a researcher. Sixty six patients with schizophrenia and schizoaffective disorder completed the SInQUE, alongside measures of psychiatric symptoms, needs and quality of life, to assess its acceptability, and concurrent and construct (convergent and discriminant) validity. The SInQUE took 45 minutes to complete and was found to have good concurrent and discriminant validity. Convergent validity was established for two domains: social integration and productivity. Preliminary findings suggest that the SInQUE may be a useful tool for assessing and monitoring social inclusion in individuals with severe mental illness. It has construct and concurrent validity with measures of unmet need and quality of life in this group. Further testing of the reliability of the SInQUE on a larger population is indicated.

  6. A Preliminary Study on the Measurement of Sediment Concentration in Hill-Slope Runoff with an Electrolyte Tracer

    Directory of Open Access Journals (Sweden)

    Xiaonan Shi Fan Zhang

    2012-01-01

    Full Text Available Sediment concentration in hill-slope runoff is an important index for soil erosion. Developing a reliable and portable measuring system of sediment concentration is a core issue for soil and water conservation study, especially for the Tibetan Plateau under unfavorable climate and terrain conditions for field investigation. Challenges include uneven distribution of sediment across a runoff section as well as difficulty in detecting a wide range of particle sizes. An electrolyte tracer, with the advantage of uniform distribution and its widely used electric-conductivity sensor, can avoid the problems of direct measurement of sediment. A new measurement method of sediment concentration in runoff with an electrolyte tracer is proposed based on a premise that sediment concentration is closely correlated with hydrodynamic dispersion coefficient of solute in runoff. In this study, an experiment system of hill-slope runoff with an electrolyte tracer and sediments is first designed. Second, two model parameters in the advective-dispersive equation of solute transport, flow velocity and diffusion coefficient, are inversely estimated by calibrating the observed concentrations of an electrolyte tracer. And third, the relationship between sediment concentrations and hydrodynamic dispersion coefficients are defined through specified regression. As a result, a measurement system of sediment concentration in hill-slope runoff with an electrolyte tracer is primarily established by integrating the relationship of variables, experiment system, and model theory.

  7. Preliminary measurement of the charged multiplicities in b, c and light quark events from Z0 decays

    International Nuclear Information System (INIS)

    1996-06-01

    Average charged multiplicities have been measured separately in b, c and light quark (u, d, s) events from Z 0 decays measured in the SLD experiment. Impact parameters of charged tracks were used to select enriched samples of b and light quark events, and reconstructed charmed mesons were used to select c quark events. We measured the charged multiplicities: anti n uds = 20.21 ± 0.10 (stat.) ± 0.17 (syst.), anti n c = 21.28 ± 0.46 (stat.) -0.33 +0.38 (syst.) and anti n b = 23.14 ± 0.10 (stat.) -0.34 +0.35 (syst.), from which we derived the differences between the total average charged multiplicities of c or b quark events and light quark events: Δ anti n c = 1.07 ± 0.47 (stat.) -0.30 +0.36 (syst.) and Δ anti n b = 2.93 ± 0.14 (stat.) -0.29 +0.30 (syst.). We compared these measurements with those at lower center-of-mass energies and with perturbative QCD predictions. These combined results are in agreement with the QCD expectations and disfavor the hypothesis of flavor-independent fragmentation

  8. Measuring Changes in Social Communication Behaviors: Preliminary Development of the Brief Observation of Social Communication Change (BOSCC)

    Science.gov (United States)

    Grzadzinski, Rebecca; Carr, Themba; Colombi, Costanza; McGuire, Kelly; Dufek, Sarah; Pickles, Andrew; Lord, Catherine

    2016-01-01

    Psychometric properties and initial validity of the Brief Observation of Social Communication Change (BOSCC), a measure of treatment-response for social-communication behaviors, are described. The BOSCC coding scheme is applied to 177 video observations of 56 young children with ASD and minimal language abilities. The BOSCC has high to excellent…

  9. Adolescents' Observations of Parent Pain Behaviors: Preliminary Measure Validation and Test of Social Learning Theory in Pediatric Chronic Pain.

    Science.gov (United States)

    Stone, Amanda L; Walker, Lynn S

    2017-01-01

    Evaluate psychometric properties of a measure of adolescents’ observations of parental pain behaviors and use this measure to test hypotheses regarding pain-specific social learning. We created a proxy-report of the Patient Reported Outcomes Measurement Information System (PROMIS) Pain Behavior–Short Form (PPB) for adolescents to report on parental pain behaviors, which we labeled the PPB-Proxy. Adolescents (n = 138, mean age = 14.20) with functional abdominal pain completed the PPB-Proxy and a parent completed the PPB. Adolescents and their parents completed measures of pain and disability during the adolescent’s clinic visit for abdominal pain. Adolescents subsequently completed a 7-day pain diary period. The PPB-Proxy moderately correlated with the PPB, evidencing that adolescents observe and can report on parental pain behaviors. Both the PPB-Proxy and PPB significantly correlated with adolescents’ pain-related disability. Parental modeling of pain behaviors could represent an important target for assessment and treatment in pediatric chronic pain patients.

  10. Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA

    International Nuclear Information System (INIS)

    Agosteo, S.; Cirrone, G.A.P.; Colautti, P.; Cuttone, G.; D'Angelo, G.; Fazzi, A.; Introini, M.V.; Moro, D.; Pola, A.; Varoli, V.

    2010-01-01

    A monolithic silicon device consisting of a matrix of micrometric cylindrical diodes (about 2 μm in thickness and 9 μm in diameter) coupled to a residual energy measurement stage E (about 500 μm in thickness) was proposed and studied for assessing the quality of a therapeutic proton beam. The device was placed at different depths inside a polymethyl-methacrylate phantom and irradiated with a modulated 62 MeV proton beam at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of the Laboratori Nazionali del Sud (LNS, Catania, Italy) of the Istituto Nazionale di Fisica Nucleare (INFN). At each phantom depth, the energy imparted in the two detector stages was measured event-by-event in coincidence mode. The distributions of the energy imparted to the cylindrical diodes were corrected for tissue-equivalence by applying an optimized procedure. In order to perform a comparison with literature data measured with a cylindrical TEPC, the distributions derived with the silicon detector were corrected for shape-equivalence. The agreement with the microdosimetric spectra measured with the TEPC was satisfactory above the detection limit imposed by the electronic noise of the silicon-based system.

  11. Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Cirrone, G.A.P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy); Colautti, P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Cuttone, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy); D' Angelo, G.; Fazzi, A.; Introini, M.V. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Moro, D. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Pola, A., E-mail: andrea.pola@polimi.i [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Varoli, V. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy)

    2010-12-15

    A monolithic silicon device consisting of a matrix of micrometric cylindrical diodes (about 2 {mu}m in thickness and 9 {mu}m in diameter) coupled to a residual energy measurement stage E (about 500 {mu}m in thickness) was proposed and studied for assessing the quality of a therapeutic proton beam. The device was placed at different depths inside a polymethyl-methacrylate phantom and irradiated with a modulated 62 MeV proton beam at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of the Laboratori Nazionali del Sud (LNS, Catania, Italy) of the Istituto Nazionale di Fisica Nucleare (INFN). At each phantom depth, the energy imparted in the two detector stages was measured event-by-event in coincidence mode. The distributions of the energy imparted to the cylindrical diodes were corrected for tissue-equivalence by applying an optimized procedure. In order to perform a comparison with literature data measured with a cylindrical TEPC, the distributions derived with the silicon detector were corrected for shape-equivalence. The agreement with the microdosimetric spectra measured with the TEPC was satisfactory above the detection limit imposed by the electronic noise of the silicon-based system.

  12. Sequential multipoint motion of the tympanic membrane measured by laser Doppler vibrometry: preliminary results for normal tympanic membrane.

    Science.gov (United States)

    Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Kitano, Hiroya

    2014-04-01

    Numerous studies have reported sound-induced motion of the tympanic membrane (TM). To demonstrate sequential motion characteristics of the entire TM by noncontact laser Doppler vibrometry (LDV), we have investigated multipoint TM measurement. A laser Doppler vibrometer was mounted on a surgical microscope. The velocity was measured at 33 points on the TM using noncontact LDV without any reflectors. Measurements were performed with tonal stimuli of 1, 3, and 6 kHz. Amplitudes were calculated from these measurements, and time-dependent changes in TM motion were described using a graphics application. TM motions were detected more clearly and stably at 1 and 3 kHz than at other frequencies. This is because the external auditory canal acted as a resonant tube near 3 kHz. TM motion displayed 1 peak at 1 kHz and 2 peaks at 3 kHz. Large amplitudes were detected in the posterosuperior quadrant (PSQ) at 1 kHz and in the PSQ and anteroinferior quadrant (AIQ) at 3 kHz. The entire TM showed synchronized movement centered on the PSQ at 1 kHz, with phase-shifting between PSQ and AIQ movement at 3 kHz. Amplitude was smaller at the umbo than at other parts. In contrast, amplitudes at high frequencies were too small and complicated to detect any obvious peaks. Sequential multipoint motion of the tympanic membrane showed that vibration characteristics of the TM differ according to the part and frequency.

  13. A Measure of Suffering in relation to Anxiety and Quality of Life in IBS Patients: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Sanda Pletikosić Tončić

    2017-01-01

    Full Text Available Irritable bowel syndrome (IBS is a chronic gastrointestinal (GI disorder with a severe impact on quality of life (QoL. We explored the relationship of a visual measure of suffering, the PRISM-RII, with quality of life (QoL and anxiety measures in IBS patients. Participants were 44 IBS patients who completed several questionnaires and kept a symptom diary for two weeks. The measures used were PRISM-RII (self-illness separation (SIS; illness perception measure (IPM; IBS-36 (IBS health related QoL; SF-36 (physical and mental health related QoL; State-Trait Anxiety Inventory (STAI-T; Visceral Sensitivity Index (VSI; GI-specific anxiety; and a symptom diary. SIS was negatively correlated to VSI, while IPM was negatively correlated to SIS and the physical component of SF-36 and positively to VSI and symptom severity. We found significant differences between participants who perceive their illness as small and those who perceive it as medium in SIS, symptom severity, VSI, and the mental component of SF-36. Participants, who perceived their illness as small, represented their illness as more distant, showed lower average symptom severity, and had lower GI-specific anxiety and higher QoL. The results indicate that IPM and SIS can be useful in discriminating patients with more prominent psychological difficulties and QoL impairment.

  14. Sink plot for runoff measurements on semi-flat terrains: preliminary data and their potential hydrological and ecological implications

    Directory of Open Access Journals (Sweden)

    Kidron Giora J.

    2014-12-01

    Full Text Available In arid and semiarid regions where water is the main limiting factor, water redistribution is regarded as an important hydrological process of great ecological value. By providing additional water to certain loci, moist pockets of great productivity are formed, characterized by high plant biomass and biological activity. These moist pockets are often a result of runon. Yet, although runoff may take place on semi-flat undulating surfaces, runoff measurements are thus far confined to slopes, where a sufficient gradient facilitates downslope water harvesting. On undulating surfaces of mounds and depressions, such as in interdunes, no quantification of the amount of water reaching depressions is feasible due to the fact that no reliable method for measuring the runoff amounts in semi-flat terrains is available. The current paper describes specific runoff plots, designed to measure runoff in depressions (sinks. These plots, termed sink plots (SPs, were operative in the Hallamish dunefield (Negev Desert, Israel. The paper presents measurements of runoff yield that were carried out between January 2013 and January 2014 on SPs and compared them to runoff obtained from crusted slope plots and fine-grained (playa surfaces. The potential hydrological and ecological implications of water redistribution within semi-flat terrains for this and other arid ecosystems are discussed.

  15. Optical properties of metals by spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Arakawa, E.T.; Inagaki, T.; Williams, M.W.

    1979-01-01

    The use of spectroscopic ellipsometry for the accurate determination of the optical properties of liquid and solid metals is discussed and illustrated with previously published data for Li and Na. New data on liquid Sn and Hg from 0.6 to 3.7 eV are presented. Liquid Sn is Drude-like. The optical properties of Hg deviate from the Drude expressions, but simultaneous measurements of reflectance and ellipsometric parameters yield consistent results with no evidence for vectorial surface effects

  16. Wind turbine transformer admittance characterization based on online time-domain measurements and preliminary results from measurements done in two transformers using a SFRA

    DEFF Research Database (Denmark)

    Arana Aristi, Iván; Holbøll, Joachim; Nielsen, Arne Hejde

    2009-01-01

    This paper presents the analysis of online time-domain measurements on the primary and secondary side of a wind turbine transformer in an Offshore Wind Farm (OWF), during one switching operation realized in the collection grid. The frequency characteristics up to 10 kHz of the current and voltage...... signals of each phase were compared and the transformers admittance characteristic was estimated based on these measurements. Based on the results from the previous analysis, it was decided to acquire a Sweep Frequency Response Analyzer (SFRA) to realize detailed transformer measurements. First...... the results from the measurements in a small dry-type transformer under laboratory conditions are presented, and finally the results from a large transformer measured in a in an industrial setting are shown....

  17. Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

    Science.gov (United States)

    Aslani, Navid; Noroozi, Siamak; Davenport, Philip; Hartley, Richard; Dupac, Mihai; Sewell, Philip

    2018-06-01

    Traditional shoulder range of movement (ROM) measurement tools suffer from inaccuracy or from long experimental setup times. Recently, it has been demonstrated that relatively low-cost wearable inertial measurement unit (IMU) sensors can overcome many of the limitations of traditional motion tracking systems. The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. Six volunteer subjects with healthy shoulders and one participant with a 'frozen' shoulder were recruited to the study. Arm movement in 3D space was plotted in spherical coordinates while the relative EMG intensity of any arm position is presented graphically. The results showed that there was an average ROM surface area of 27291 ± 538 deg 2 among all six healthy individuals and a ROM surface area of 13571 ± 308 deg 2 for the subject with frozen shoulder. All three sections of the deltoid show greater EMG activity at higher elevation angles. Using such tools enables individuals, surgeons and physiotherapists to measure the maximum envelope of motion in conjunction with muscle activity in order to provide an objective assessment of shoulder performance in the voluntary 3D workspace. Graphical abstract The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. The assessment tool consists of an IMU sensor, an EMG sensor, a microcontroller and a Bluetooth module. The assessment tool was attached to subjects arm. Individuals were instructed to move their arms with the elbow fully extended. They were then asked to provide the maximal voluntary elevation envelope of the arm in 3D space in multiple attempts starting from a small movement envelope going to the biggest

  18. A preliminary investigation of a new pictorial method of measuring aggression-supportive cognition among young aggressive males.

    Science.gov (United States)

    Hutchings, Jade N; Gannon, Theresa A; Gilchrist, Elizabeth

    2010-04-01

    A new pictorial assessment was developed to measure aggression-supportive cognitions among young aggressive male students. The assessment was comprised of 17 watercolor ambiguous sketches that could be interpreted in either an aggressive or a benign manner (e.g., two young people facing each other with their arms folded). The results showed that high trait aggressive male students were more likely to make hostile attributions of the pictures, providing significantly more themes of entitlement and power in the stories they generated about the pictures. Aggressive male students also endorsed significantly more aggression-supportive cognitions on a self-report measure and provided some supporting qualitative accounts of physically aggressive encounters. The results of this study are discussed and evaluated with reference to future work with young violent adolescents.

  19. Preliminary analysis of columnar aerosol properties in relation to surface PM measurements in the DAMOCLES 2006 field campaign (Spain)

    Science.gov (United States)

    Estelles, V.; Esteve, A.; Pey, J.; Martinez-Lozano, J. A.; Utrillas, M. P.; Querol, X.; de La Rosa, J.; Gonzalez-Castanedo, Y.; Alastuey, A.; Gangoiti, G.

    2009-04-01

    The DAMOCLES network is a Spanish thematic network, started in 2004, whose main objective is the establishment of a link among the different groups that perform research on atmospheric aerosols in Spain. Under the DAMOCLES coordination, a field campaign was held in summer 2006 at the INTA installations (El Arenosillo, Huelva) for the intercomparison of different kind of instruments devoted to in - situ and columnar aerosol measurement. During this field campaign, two daily meteorological soundings were carried out at noon and midnight for characterization of the atmospheric condition. A plane was also flown by the National Institute of Aerospace Technology (INTA) to carry airborne sensors for measuring different atmospheric factors: meteorological parameters, ozone with a 2BTech analyzer, and aerosol particle size distributions in the range (0.01-2) microns, by using a PCASP probe. The columnar aerosol properties were measured by seven CIMEL CE318 sun photometers. For in situ aerosol characterization, high volume collectors (DIGITEL and MCV) with DIGITEL for PM10, PM2.5 and PM1 measurement were used, with two cascade impactors for particulate matter measurement in 7 -8 granulometric fractions. For the PM10, PM2.5 and PM1 measurement, quartz fibre filters of 150 mm diameter were adapted. Other in situ deployed instruments were a Scanning Mobility Particle Sizer (SMPS, Model 3936), two Aerodynamic Particle Sizer (APS Model 3321) and one Grimm Spectrometer (Model #190). For characterization of the aerosol scattering at ground level, three integrating nephelometers TSI-3563 were used. For the columnar profiling we deployed five LIDAR instruments. In this study we have related the columnar aerosol measurements retrieved with one CE318 sun photometer to the surface PM measurements, mainly in some interesting situations where nearby pollution sources were influencing the local atmosphere. For the sun photometric analysis, we have applied the EuroSkyRad package (ESR

  20. Preliminary psychometric properties of the Acceptance and Action Questionnaire-II: a revised measure of psychological inflexibility and experiential avoidance.

    Science.gov (United States)

    Bond, Frank W; Hayes, Steven C; Baer, Ruth A; Carpenter, Kenneth M; Guenole, Nigel; Orcutt, Holly K; Waltz, Tom; Zettle, Robert D

    2011-12-01

    The present research describes the development and psychometric evaluation of a second version of the Acceptance and Action Questionnaire (AAQ-II), which assesses the construct referred to as, variously, acceptance, experiential avoidance, and psychological inflexibility. Results from 2,816 participants across six samples indicate the satisfactory structure, reliability, and validity of this measure. For example, the mean alpha coefficient is .84 (.78-.88), and the 3- and 12-month test-retest reliability is .81 and .79, respectively. Results indicate that AAQ-II scores concurrently, longitudinally, and incrementally predict a range of outcomes, from mental health to work absence rates, that are consistent with its underlying theory. The AAQ-II also demonstrates appropriate discriminant validity. The AAQ-II appears to measure the same concept as the AAQ-I (r=.97) but with better psychometric consistency. Copyright © 2011. Published by Elsevier Ltd.

  1. The Border Community & Immigration Stress Scale: A Preliminary Examination of a Community Responsive Measure in Two Southwest Samples

    Science.gov (United States)

    Carvajal, Scott C.; Rosales, Cecilia; Rubio-Goldsmith, Raquel; Sabo, Samantha; Ingram, Maia; McClelland, Debra Jean; Redondo, Floribella; Torres, Emma; Romero, Andrea J.; Oleary, Anna Ochoa; Sanchez, Zoila; de Zapien, Jill Guernsey

    2015-01-01

    Background Understanding contemporary socio-cultural stressors may assist educational, clinical and policy-level health promotion efforts. This study presents descriptive findings on a new measure, the Border Community & Immigration Stress Scale (BCISS). Methods The data were from two community surveys as part of community based participatory projects conducted in the Southwestern US border region. This scale includes stressful experiences reflected in extant measures, with new items reflecting heightened local migration pressures and health care barriers. Results Stressors representing each main domain, including novel ones, were reported with frequency and at high intensity in the predominantly Mexican-descent samples. Total stress was also significantly associated with mental and physical health indicators. Discussion The study suggests particularly high health burdens tied to the experience of stressors in the US border region. Further, many of the stressors are also likely relevant for other communities within developed nations also experiencing high levels of migration. PMID:22430894

  2. Preliminary measurements of gamma ray effects on characteristics of broad-band GaAs field-effect transistor preamplifiers

    International Nuclear Information System (INIS)

    Jackson, H.G.; Shimizu, T.T.; Leskovar, B.

    1985-01-01

    The effect of gamma radiation on electrical characteristics of cryogenically cooled broad-band low-noise microwave preamplifiers has been preliminarily evaluated. The change in the gain and noise figure of a 1-2 GHz preamplifier using GaAs microwave transistors was determined at gamma doses between 10 5 rad to 5 /times/ 10 8 rad. The gain and noise figure was measured at ambient temperatures of 300 K and 80 K. 8 refs., 2 figs

  3. Development and preliminary validation of a self-report measure of psychopathic personality traits in noncriminal populations.

    Science.gov (United States)

    Lilienfeld, S O; Andrews, B P

    1996-06-01

    Research on psychopathology has been hindered by persisting difficulties and controversies regarding its assessment. The primary goals of this set of studies were to (a) develop, and initiate the construct validation of, a self-report measure that assesses the major personality traits of psychopathy in noncriminal populations and (b) clarify the nature of these traits via an exploratory approach to test construction. This measure, the Psychopathic Personality Inventory (PPI), was developed by writing items to assess a large number of personality domains relevant to psychopathy and performing successive item-level factor analyses and revisions on three undergraduate samples. The PPI total score and its eight subscales were found to possess satisfactory internal consistency and test-retest reliability. In four studies with undergraduates, the PPI and its subscales exhibited a promising pattern of convergent and discriminant validity with self-report, psychiatric interview, observer rating, and family history data. In addition, the PPI total score demonstrated incremental validity relative to several commonly used self-report psychopathy-related measures. Future construct validation studies, unresolved conceptual issues regarding the assessment of psychopathy, and potential research uses of the PPI are outlined.

  4. Preliminary results of absolute and high-precision gravity measurements at the Nevada Test Site and vicinity, Nevada

    International Nuclear Information System (INIS)

    Zumberge, M.A.; Harris, R.N.; Oliver, H.W.; Sasagawa, G.S.; Ponce, D.A.

    1988-01-01

    Absolute gravity measurements were made at 4 sites in southern Nevada using the absolute gravity free-fall apparatus. Three of the sites are located on the Nevada Test Site at Mercury, Yucca Pass, and in northern Jackass Flats. The fourth site is at Kyle Canyon ranger station near Charleston Park where observed gravity is 216.19 mGal lower than at Mercury. Although there is an uncertainty of about 0.02 mGal in the absolute measured values, their gravity differences are considered accurate to about 0.03 mGal. Therefore, the absolute measurements should provide local control for the calibration of gravity meters between Mercury and Kyle Canyon ranger station to about 1 to 2 parts in 10,000. The average gravity differences between Mercury and Kyle Canyon obtained using LaCoste and Romberg gravity meters is 216.13 mGal, 0.06 mGal lower, or 3 parts in 10,000 lower than using the absolute gravity meter. Because of the discrepancy between the comparison of the absolute and relative gravity meters, more absolute and relative gravity control in southern Nevada, as well as the Mt. Hamilton area where the LaCoste and Romberg instruments were calibrated, is needed. Multiple gravity meter ties were also made between each of the four absolute stations to nearby base stations located on bedrock. These stations were established to help monitor possible real changes in gravity at the absolute sites that could result from seasonal variations in the depth to the water table or other local mass changes. 8 refs., 16 figs., 7 tabs

  5. Survivor-Defined Practice in Domestic Violence Work: Measure Development and Preliminary Evidence of Link to Empowerment.

    Science.gov (United States)

    Goodman, Lisa A; Thomas, Kristie; Cattaneo, Lauren Bennett; Heimel, Deborah; Woulfe, Julie; Chong, Siu Kwan

    2016-01-01

    Survivor-defined practice, characterized by an emphasis on client choice, partnership, and sensitivity to the unique needs, contexts, and coping strategies of individual survivors, is an aspirational goal of the domestic violence (DV) movement, assumed to be a key contributor to empowerment and other positive outcomes among survivors. Despite its central role in DV program philosophy, training, and practice, however, our ability to assess its presence and its presumed link to well-being has been hampered by the absence of a way to measure it from survivors' perspectives. As part of a larger university-community collaboration, this study had two aims: (a) to develop a measure of survivor-defined practice from the perspective of participants, and (b) to assess its relationship to safety-related empowerment after controlling for other contributors to survivor well-being (e.g., financial stability and social support). Results supported the reliability and validity of the Survivor-Defined Practice Scale (SDPS), a nine-item measure that assesses participants' perception of the degree to which their advocates help them achieve goals they set for themselves, facilitate a spirit of partnership, and show sensitivity to their individual needs and styles. The items combined to form one factor indicating that the three theoretical aspects of survivor-defined practice may be different manifestations of one underlying construct. Results also support the hypothesized link between survivor-defined practice and safety-related empowerment. The SDPS offers DV programs a mechanism for process evaluation that is rigorous and rooted in the feminist empowerment philosophy that so many programs espouse. © The Author(s) 2014.

  6. Chlorine-36 measurements in the Murray Basin; preliminary results from the Victorian and South Australian Mallee region

    International Nuclear Information System (INIS)

    Davie, R.F.; Calf, G.E.; Bird, J.R.; Topham, S.; Kellett, J.R.; Evans, W.R.; Fifield, L.K.; Ophel, T.R.

    1989-01-01

    Chlorine-36 analyses of groundwater samples from 18 wells in the Victorian and South Australian Mallee region of the Murray Basin have been carried out using the technique of accelerator mass spectrometry. Results of these analyses are discussed and presented as evidence for significant recharge from rainfall over much of the study area to the underlying Murray Group limestone aquifer. In addition, results indicate areas where further 36 Cl measurements of Murray Mallee groundwater would provide useful hydrological information on both recharge and discharge mechanisms. 34 refs., 1 tab., 7 figs

  7. Mössbauer spectroscopic study of 57Fe metabolic transformations in the rhizobacterium Azospirillum brasilense Sp245

    Science.gov (United States)

    Kamnev, Alexander A.; Tugarova, Anna V.; Kovács, Krisztina; Biró, Borbála; Homonnay, Zoltán; Kuzmann, Ernő

    2014-04-01

    Preliminary 57Fe transmission Mössbauer spectroscopic data were obtained for the first time for live cells of the plant-growth-promoting rhizobacterium Azospirillum brasilense (wild-type strain Sp245) grown aerobically with 57FeIII-nitrilotriacetate (NTA) complex as a sole source of iron. The results obtained have shown that live cells actively reduce part of the assimilated iron(III) to iron(II), the latter amounting up to 33 % of total cellular iron after 18 h of growth, and 48 % after additional 3 days of storage of the dense wet cell suspension in nutrient-free saline solution in air at room temperature (measured at 80 K). The cellular iron(II) was found to be represented by two quadrupole doublets of different high-spin forms, while the parameters of the cellular iron(III) were close to those typical for bacterioferritins.

  8. Liver stiffness measured by magnetic resonance elastography as a risk factor for hepatocellular carcinoma: a preliminary case-control study

    Energy Technology Data Exchange (ETDEWEB)

    Motosugi, Utaroh; Ichikawa, Tomoaki; Koshiishi, Tsuyota; Sano, Katsuhiro; Morisaka, Hiroyuki; Ichikawa, Shintaro; Araki, Tsutomu [University of Yamanashi, Department of Radiology, Yamanashi-ken (Japan); Enomoto, Nobuyuki [University of Yamanashi, 1st Department of Internal Medicine, Yamanashi (Japan); Matsuda, Masanori; Fujii, Hideki [University of Yamanashi, 1st Department of Surgery, Yamanashi (Japan)

    2013-01-15

    To examine if liver stiffness measured by magnetic resonance elastography (MRE) is a risk factor for hepatocellular carcinoma (HCC) in patients with chronic liver disease. By reviewing the records of magnetic resonance (MR) examinations performed at our institution, we selected 301 patients with chronic liver disease who did not have a previous medical history of HCC. All patients underwent MRE and gadoxetic acid-enhanced MR imaging. HCC was identified on MR images in 66 of the 301 patients, who were matched to controls from the remaining patients without HCC according to age. MRE images were obtained by visualising elastic waves generated in the liver by pneumatic vibration transferred via a cylindrical passive driver. Risk factors of HCC development were determined by the odds ratio with logistic regression analysis; gender and liver stiffness by MRE and serum levels of aspartate transferase, alanine transferase, alpha-fetoprotein, and protein induced by vitamin K absence-II. Multivariate analysis revealed that only liver stiffness by MRE was a significant risk factor for HCC with an odds ratio (95 % confidence interval) of 1.38 (1.05-1.84). Liver stiffness measured by MRE is an independent risk factor for HCC in patients with chronic liver disease. (orig.)

  9. The role of self-efficacy in inflammatory bowel disease management: preliminary validation of a disease-specific measure.

    Science.gov (United States)

    Keefer, Laurie; Kiebles, Jennifer L; Taft, Tiffany H

    2011-02-01

    Inflammatory bowel diseases (IBDs) require self-management skills that may be influenced by self-efficacy (SE). Self-efficacy represents an individual's perception of his or her ability to organize and execute the behaviors necessary to manage disease. The goal of this study was to develop a valid and reliable measure of IBD-specific SE that can be used in clinical and research contexts. One hundred and twenty-two adults with a verified IBD diagnosis participated in the study. Data were pooled from 2 sources: patients from an outpatient university gastroenterology clinic (n=42) and a sample of online respondents (n=80). All participants (N=122) completed the IBD Self-Efficacy Scale (IBD-SES) and the Inflammatory Bowel Disease Questionnaire. Additionally, online participants completed the Brief Symptom Inventory-18 and the Rosenberg Self-Esteem Scale, whereas those in the clinic sample completed the Perceived Health Competence Scale, the Perceived Stress Questionnaire, and the Short Form Version 2 Health Survey. The IBD-SES was initially constructed to identify 4 distinct theoretical domains of self-efficacy: (1) managing stress and emotions, (2) managing medical care, (3) managing symptoms and disease, and (4) maintaining remission. The 29-item IBD-SES has high internal consistency (r=0.96), high test-retest reliability (r=0.90), and demonstrates strong construct and concurrent validity with established measures. The IBD-SES is a critical first step toward addressing an important psychological construct that could influence treatment outcomes in IBD.

  10. Some preliminary results of post-dryout heat transfer measurements at low qualities and pressures up to 20 bar

    International Nuclear Information System (INIS)

    Swinnerton, D.; Pearson, K.G.; O'Mahoney, R.

    1987-01-01

    Steady state data have been obtained on post-dryout heat transfer for flow in a tube of inside diameter 10 mm and length 920 mm. The experiments covered mass velocities up to 200 kg/m 2 s at 10 and 20 bar and up to 1000 kg/m 2 s at 2 and 5 bar. Inlet qualities were close to zero and the equilibrium quality at exit ranged up to 60%. The tube was prevented from rewetting by massive copper hot patches, brazed to it at each end. Surface temperature measurements were made along the length of the tube. An in-stream thermocouple inserted into the flow at exit from the tube provided a measure of vapor temperature at this location. Typical sets of data are presented and the trends discussed. These new data extend the range of the available database against which the combined effects of the heat transfer and hydraulic models in reactor safety codes can be assessed. Comparisons are made with predictions obtained using the TRAC-PF1/MOD1 computer code and the reflood code BERTHA

  11. The Complex Trauma Questionnaire (ComplexTQ:Development and preliminary psychometric properties of an instrument for measuring early relational trauma

    Directory of Open Access Journals (Sweden)

    Carola eMaggiora Vergano

    2015-09-01

    Full Text Available Research on the etiology of adult psychopathology and its relationship with childhood trauma has focused primarily on specific forms of maltreatment. This study developed an instrument for the assessment of childhood and adolescence trauma that would aid in identifying the role of co-occurring childhood stressors and chronic adverse conditions. The Complex Trauma Questionnaire (ComplexTQ, in both clinician and self-report versions, is a measure for the assessment of multi-type maltreatment: physical, psychological, and sexual abuse; physical and emotional neglect as well as other traumatic experiences, such rejection, role reversal, witnessing domestic violence, separations, and losses. The four-point Likert scale allows to specifically indicate with which caregiver the traumatic experience has occurred. A total of 229 participants, a sample of 79 nonclinical and that of 150 high-risk and clinical participants, were assessed with the ComplexTQ clinician version applied to Adult Attachment Interview (AAI transcripts. Initial analyses indicate acceptable inter-rater reliability. A good fit to a 6-factor model regarding the experience with the mother and to a 5-factor model with the experience with the father was obtained; the internal consistency of factors derived was good. Convergent validity was provided with the AAI scales. ComplexTQ factors discriminated normative from high-risk and clinical samples. The findings suggest a promising, reliable, and valid measurement of early relational trauma that is reported; furthermore, it is easy to complete and is useful for both research and clinical practice.

  12. Preliminary study on carprofen concentration measurements after transcutaneous treatment with Vetdrop® in a microfracture joint defect model in sheep.

    Science.gov (United States)

    Sidler, Michèle; Fouché, Nathalie; Meth, Ingmar; von Hahn, Friedrich; von Rechenberg, Brigitte; Kronen, Peter W

    2014-12-09

    The present preliminary study describes concentration time courses of the NSAID carprofen in the plasma and synovial fluid in a microfrature sheep model after transcutaneous treatments with a novel application device (Vetdrop®). To treat circumscribed inflammatory processes a transcutaneous application device could potentially be beneficial. After transcutaneous application normally lower systemic concentrations are measured which may reduce the incidence of side effects, whereas efficacy is still maintained. In this study carprofen was used based on its capacity to provide analgesia after orthopaedic procedures in sheep and it is considered that it may have a positive influence on the healing of cartilage in low concentrations. In all transcutaneously treated animals, carprofen plasma concentrations exceeded those of synovial fluid, although plasma levels remained significantly reduced (300-fold) as compared to carprofen administered intravenously. Furthermore, in contrast to the intravenously treated animals, a modest accumulation of carprofen in plasma and synovial fluid was observed in the transcutaneously treated animals over the 6-week treatment period. The transcutaneously administered carprofen using the Vetdrop® device penetrated the skin and both, plasma- and synovial concentrations could be measured repeatedly over time. This novel device may be considered a valuable transcutaneous drug delivery system.

  13. Preliminary measurement of mean B hadrons lifetime via the B → J/ψX, J/ψ → μ"+μ"- channel using the DELPHI (LEP) detector

    International Nuclear Information System (INIS)

    Ledroit, Fabienne

    1991-01-01

    This thesis is a contribution to the study of the b quark within the framework of the DELPHI experiment, at the LEP collider. More precisely, this work is based on the search of the J/ψ via its decay into a muon pair. The first analysis, mainly built on muon selection, allows us to obtain a sample of events enriched in J/ψ → μ"+μ"- decays. A preliminary estimation of the inclusive branching ratio BR(e"+e"- → J/ψ) is deduced from this sample. This estimation is compatible with the expected branching ratio via B → J/ψ and does not exclude a direct production mode, that is during the hadronization of the quarks at the Z"0 decay vertex. The second analysis makes use of the same enriched sample and tests a method, based on vertex reconstruction (primary vertex and secondary dimuon vertex), supposed to measure the mean B lifetime. Encouraging results are obtained, which moreover, give rise to new prospects. Indeed, the method can possibly be converted to the measurement of the direct J/ψ production ratio if one assumes the mean B lifetime to be obtained independently. (author) [fr

  14. Universal relation between spectroscopic constants

    Indian Academy of Sciences (India)

    (3) The author has used eq. (6) of his paper to calculate De. This relation leads to a large deviation from the correct value depending upon the extent to which experimental values are known. Guided by this fact, in our work, we used experimentally observed De values to derive the relation between spectroscopic constants.

  15. The VANDELS ESO spectroscopic survey

    Science.gov (United States)

    McLure, R. J.; Pentericci, L.; Cimatti, A.; Dunlop, J. S.; Elbaz, D.; Fontana, A.; Nandra, K.; Amorin, R.; Bolzonella, M.; Bongiorno, A.; Carnall, A. C.; Castellano, M.; Cirasuolo, M.; Cucciati, O.; Cullen, F.; De Barros, S.; Finkelstein, S. L.; Fontanot, F.; Franzetti, P.; Fumana, M.; Gargiulo, A.; Garilli, B.; Guaita, L.; Hartley, W. G.; Iovino, A.; Jarvis, M. J.; Juneau, S.; Karman, W.; Maccagni, D.; Marchi, F.; Mármol-Queraltó, E.; Pompei, E.; Pozzetti, L.; Scodeggio, M.; Sommariva, V.; Talia, M.; Almaini, O.; Balestra, I.; Bardelli, S.; Bell, E. F.; Bourne, N.; Bowler, R. A. A.; Brusa, M.; Buitrago, F.; Caputi, K. I.; Cassata, P.; Charlot, S.; Citro, A.; Cresci, G.; Cristiani, S.; Curtis-Lake, E.; Dickinson, M.; Fazio, G. G.; Ferguson, H. C.; Fiore, F.; Franco, M.; Fynbo, J. P. U.; Galametz, A.; Georgakakis, A.; Giavalisco, M.; Grazian, A.; Hathi, N. P.; Jung, I.; Kim, S.; Koekemoer, A. M.; Khusanova, Y.; Le Fèvre, O.; Lotz, J. M.; Mannucci, F.; Maltby, D. T.; Matsuoka, K.; McLeod, D. J.; Mendez-Hernandez, H.; Mendez-Abreu, J.; Mignoli, M.; Moresco, M.; Mortlock, A.; Nonino, M.; Pannella, M.; Papovich, C.; Popesso, P.; Rosario, D. P.; Salvato, M.; Santini, P.; Schaerer, D.; Schreiber, C.; Stark, D. P.; Tasca, L. A. M.; Thomas, R.; Treu, T.; Vanzella, E.; Wild, V.; Williams, C. C.; Zamorani, G.; Zucca, E.

    2018-05-01

    VANDELS is a uniquely-deep spectroscopic survey of high-redshift galaxies with the VIMOS spectrograph on ESO's Very Large Telescope (VLT). The survey has obtained ultra-deep optical (0.48 studies. Using integration times calculated to produce an approximately constant signal-to-noise ratio (20 motivation, survey design and target selection.

  16. On a Generalized Entropy Measure Leading to the Pathway Model with a Preliminary Application to Solar Neutrino Data

    Directory of Open Access Journals (Sweden)

    Hans J. Haubold

    2013-09-01

    Full Text Available An entropy for the scalar variable case, parallel to Havrda-Charvat entropy, was introduced by the first author, and the properties and its connection to Tsallis non-extensive statistical mechanics and the Mathai pathway model were examined by the authors in previous papers. In the current paper, we extend the entropy to cover the scalar case, multivariable case, and matrix variate case. Then, this measure is optimized under different types of restrictions, and a number of models in the multivariable case and matrix variable case are obtained. Connections of these models to problems in statistical and physical sciences are pointed out. An application of the simplest case of the pathway model to the interpretation of solar neutrino data by applying standard deviation analysis and diffusion entropy analysis is provided.

  17. Preliminary measurements of tritium, deuterium and oxygen-18 in lakes and groundwater of volcanic Rotorua region, New Zealand

    International Nuclear Information System (INIS)

    Taylor, C.B.; Freestone, H.J.; Nairn, I.A.

    1977-06-01

    This report presents an initial survey of the isotopic characteristics of non-hydrothermal waters of Rotorua region. Measurements of deuterium, oxygen and tritium have been made on samples collected between 1970 and 1973. Some major springs emerging close to land-locked lakes have been identified as containing mixtures of lake-derived water and precipitation-derived recharge in the catchments between lake and spring. The stable isotope composition of precipitation-recharged groundwater occupies a fairly narrow range, but is nevertheless seperable into two distinct isotopic families. The circumstances leading to these isotopic differences are not yet fully understood. This isotopic data has been gathered with a view to identifying hydrological problems in the region capable of study by isotopic methods and as essential background data to studies of the region's many hydrothermal systems. (auth.)

  18. A preliminary study to assess the construct validity of a cultural intelligence measure on a South African sample

    Directory of Open Access Journals (Sweden)

    Bright Mahembe

    2014-09-01

    Research purpose: The purpose of the current study was to assess the construct validity of the CQS on a South African sample. The results of the psychometric assessment offer some important insights into the factor structure of the cultural intelligence construct. Motivation for the study: The current study sought to provide some practical validity confirmation of the CQS for the effective management of cultural diversity in the South African context. Research approach, design and method: The CQS was administered on a non-probability sample of 229 young adults in South Africa. Item analysis was performed to ascertain reliability. Exploratory factor analysis was used to test the unidimensionality of CQS subscales. The first-order and second-order factor structures underlying contemporary models of cultural intelligence were tested using confirmatory factor analysis. Main findings: Results indicated that the CQS is a reliable and valid measure of cultural intelligence as evidenced by the high internal consistency coefficients in all the subscales. Good construct validity for both the first-order and second-order models was obtained via confirmatory factor analysis. Practical/managerial implications: The study finds good measurement properties of the CQS in a South African context. The CQS can be confidently used for applications such as selecting, training and developing a more culturally competent workforce. Contribution: The study extends the body of knowledge on the reliability and construct validity of the CQS in the South African milieu. It further indicates that cultural intelligence can be represented by a general cultural intelligence factor that drives more specific dimensions of cultural intelligence.

  19. S-TOFHLA in mild Alzheimer's disease and Mild Cognitive Impairment patients as a measure of functional literacy: Preliminary study

    Directory of Open Access Journals (Sweden)

    Maira Okada de Oliveira

    Full Text Available Abstract The greatest difficulty in diagnosing cognitive loss in our population is the diversity of its education which has a broad spectrum ranging from illiteracy, functional illiteracy and different degrees of literacy, even in those with the same level of schooling. Objectives: To verify whether there is impairment on the S-TOFHLA among individuals with AD and MCI compared with healthy controls, and to compare performance on the S-TOFHLA performance with neuropsychological tests and the scores achieved on the Raven's Colored Matrices and Vocabulary and Block Design (WAIS-III as a measure of estimated intellectual level. Methods: 59 subjects: controls (n=23; age 70.96±8.31y; schooling 10.2±5.87y; 6 men, MCI patients (n=11; age 74.18±8.12y; schooling 7.55±4.32y; 5 men and AD patients (n=25; age 76.16±4.96y; schooling 7.32±4.78y; 10 men were submitted to neuropsychological assessment, S-TOFHLA and functional evaluation. Results: Differences on BD, Raven and Estimated IQ were found between controls and MCI patients as well as controls and AD patients. On the S-TOFHLA, differences were found between MCI and AD patients, controls and AD patients, but not between control and MCI groups. S-TOFHLA performance correlated strongly with schooling and all neuropsychological tests, except Clock Drawing. Conclusions: The S-TOFHLA seems to be a useful measure for determining the level of literacy in MCI patients, but not in AD patients. S-TOFHLA performance was more closely associated with neuropsychological test scores than were years of education and seems to be a good predictor of level of literacy. The Vocabulary subtest proved to be uninfluenced by the disease process in early stages and preserved in both MCI and AD patients, showing that semantic memory and crystallized intelligence are preserved.

  20. Failure mode analysis of preliminary design of ITER divertor impurity monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki

    2016-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • Failure mode of DIM was prepared for RAMI analysis. • RAMI analysis on DIM was performed to reduce technical risks. - Abstract: The objective of the divertor impurity influx monitor (DIM) for ITER is to measure the parameters of impurities and hydrogen isotopes (tritium, deuterium, and hydrogen) in divertor plasma using visible and UV spectroscopic techniques in the 200–1000 nm wavelength range. In ITER, special provisions are required to ensure accuracy and full functionality of the diagnostic components under harsh conditions (high temperature, high magnetic field, high vacuum condition, and high radiation field). Japan Domestic Agency is preparing the preliminary design of the ITER DIM system, which will be installed in the upper, equatorial and lower ports. The optical and mechanical designs of the DIM are conducted to fit ITER’s requirements. The optical and mechanical designs meet the requirements of spatial resolution. Some auxiliary systems were examined via prototyping. The preliminary design of the ITER DIM system was evaluated by RAMI analysis. The availability of the designed system is adequately high to satisfy the project requirements. However, some equipment does not have certain designs, and this may cause potential technical risks. The preliminary design should be modified to reduce technical risks and to prepare the final design.

  1. Preliminary testing of the reliability and feasibility of SAGE: a system to measure and score engagement with and use of research in health policies and programs.

    Science.gov (United States)

    Makkar, Steve R; Williamson, Anna; D'Este, Catherine; Redman, Sally

    2017-12-19

    Few measures of research use in health policymaking are available, and the reliability of such measures has yet to be evaluated. A new measure called the Staff Assessment of Engagement with Evidence (SAGE) incorporates an interview that explores policymakers' research use within discrete policy documents and a scoring tool that quantifies the extent of policymakers' research use based on the interview transcript and analysis of the policy document itself. We aimed to conduct a preliminary investigation of the usability, sensitivity, and reliability of the scoring tool in measuring research use by policymakers. Nine experts in health policy research and two independent coders were recruited. Each expert used the scoring tool to rate a random selection of 20 interview transcripts, and each independent coder rated 60 transcripts. The distribution of scores among experts was examined, and then, interrater reliability was tested within and between the experts and independent coders. Average- and single-measure reliability coefficients were computed for each SAGE subscales. Experts' scores ranged from the limited to extensive scoring bracket for all subscales. Experts as a group also exhibited at least a fair level of interrater agreement across all subscales. Single-measure reliability was at least fair except for three subscales: Relevance Appraisal, Conceptual Use, and Instrumental Use. Average- and single-measure reliability among independent coders was good to excellent for all subscales. Finally, reliability between experts and independent coders was fair to excellent for all subscales. Among experts, the scoring tool was comprehensible, usable, and sensitive to discriminate between documents with varying degrees of research use. Secondly, the scoring tool yielded scores with good reliability among the independent coders. There was greater variability among experts, although as a group, the tool was fairly reliable. The alignment between experts' and independent

  2. Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

    International Nuclear Information System (INIS)

    Falco, Maria Daniela; Fontanarosa, Davide; Miceli, Roberto; Carosi, Alessandra; Santoni, Riccardo; D'Andrea, Marco

    2011-01-01

    Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4 o . For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22 o ). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be

  3. A Preliminary Study on the Measures to Assess the Organizational Safety: The Cultural Impact on Human Error Potential

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Lee, Yong Hee

    2011-01-01

    The Fukushima I nuclear accident following the Tohoku earthquake and tsunami on 11 March 2011 occurred after twelve years had passed since the JCO accident which was caused as a result of an error made by JCO employees. These accidents, along with the Chernobyl accident, associated with characteristic problems of various organizations caused severe social and economic disruptions and have had significant environmental and health impact. The cultural problems with human errors occur for various reasons, and different actions are needed to prevent different errors. Unfortunately, much of the research on organization and human error has shown widely various or different results which call for different approaches. In other words, we have to find more practical solutions from various researches for nuclear safety and lead a systematic approach to organizational deficiency causing human error. This paper reviews Hofstede's criteria, IAEA safety culture, safety areas of periodic safety review (PSR), teamwork and performance, and an evaluation of HANARO safety culture to verify the measures used to assess the organizational safety

  4. Preliminary results from the laboratory study of a flow-through fluorometer for measuring oil-in-water levels

    International Nuclear Information System (INIS)

    Lambert, P.; Fieldhouse, B.; Wang, Z.; Fingas, M.; Pearson, L.; Collazzi, E.

    2000-01-01

    An extensive bench-scale test program was conducted to evaluate the performance of the Turner Instruments flow-through model 10AU and model 10 fluorometers for measuring real-time concentrations of oil in water. The results were compared with alternative total petroleum hydrocarbon (TPH) methods. The 10AU model was equipped with a long wavelength optical kit, the other with the short wavelength optical kit for diesel fuels and light refined oil products. The oils tested were Alberta Sweet Mixed Blend crude oil, Prudhoe Bay crude oil, Bunker C fuel oil and diesel fuel. It was determined that the long wavelength optical kit has minimal capacity to detect and quantify diesel fuels compared to the short wavelength kit, although the latter exhibits a lower performance level. A calibration procedure was also established for oil-in-water to convert the real-time fluorometer data to oil concentrations. Initial comparisons of these tests with standard infrared and gas chromatography procedures were promising. It was determined that fluorometer data can differentiate between various oil-in-water concentrations, but regularly gives concentration values double those of the solvent extraction, infrared or gas chromatography methods. Future studies are being planned to relate the results of this study to the chemical composition of various oils. 16 refs., 5 tabs., 6 figs

  5. A Preliminary Study on the Measures to Assess the Organizational Safety: The Cultural Impact on Human Error Potential

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, Yong Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    The Fukushima I nuclear accident following the Tohoku earthquake and tsunami on 11 March 2011 occurred after twelve years had passed since the JCO accident which was caused as a result of an error made by JCO employees. These accidents, along with the Chernobyl accident, associated with characteristic problems of various organizations caused severe social and economic disruptions and have had significant environmental and health impact. The cultural problems with human errors occur for various reasons, and different actions are needed to prevent different errors. Unfortunately, much of the research on organization and human error has shown widely various or different results which call for different approaches. In other words, we have to find more practical solutions from various researches for nuclear safety and lead a systematic approach to organizational deficiency causing human error. This paper reviews Hofstede's criteria, IAEA safety culture, safety areas of periodic safety review (PSR), teamwork and performance, and an evaluation of HANARO safety culture to verify the measures used to assess the organizational safety

  6. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Preliminary results of real-time in-vitro electronic speckle pattern interferometry (ESPI) measurements in otolaryngology

    Science.gov (United States)

    Conerty, Michelle D.; Castracane, James; Cacace, Anthony T.; Parnes, Steven M.; Gardner, Glendon M.; Miller, Mitchell B.

    1995-05-01

    Electronic Speckle Pattern Interferometry (ESPI) is a nondestructive optical evaluation technique that is capable of determining surface and subsurface integrity through the quantitative evaluation of static or vibratory motion. By utilizing state of the art developments in the areas of lasers, fiber optics and solid state detector technology, this technique has become applicable in medical research and diagnostics. Based on initial support from NIDCD and continued support from InterScience, Inc., we have been developing a range of instruments for improved diagnostic evaluation in otolaryngological applications based on the technique of ESPI. These compact fiber optic instruments are capable of making real time interferometric measurements of the target tissue. Ongoing development of image post- processing software is currently capable of extracting the desired quantitative results from the acquired interferometric images. The goal of the research is to develop a fully automated system in which the image processing and quantification will be performed in hardware in near real-time. Subsurface details of both the tympanic membrane and vocal cord dynamics could speed the diagnosis of otosclerosis, laryngeal tumors, and aid in the evaluation of surgical procedures.

  8. Spectroscopic diagnostics of high temperature plasmas

    International Nuclear Information System (INIS)

    Moos, W.

    1990-01-01

    A three-year research program for the development of novel XUV spectroscopic diagnostics for magnetically confined fusion plasmas is proposed. The new diagnostic system will use layered synthetic microstructures (LSM) coated, flat and curved surfaces as dispersive elements in spectrometers and narrow band XUV filter arrays. In the framework of the proposed program we will develop impurity monitors for poloidal and toroidal resolved measurements on PBX-M and Alcator C-Mod, imaging XUV spectrometers for electron density and temperature fluctuation measurements in the hot plasma core in TEXT or other similar tokamaks and plasma imaging devices in soft x-ray light for impurity behavior studies during RF heating on Phaedrus T and carbon pellet ablation in Alcator C-Mod. Recent results related to use of multilayer in XUV plasma spectroscopy are presented. We also discuss the latest results reviewed to q o and local poloidal field measurements using Zeeman polarimetry

  9. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement.

    Science.gov (United States)

    Saito, Masatoshi

    2007-11-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity-in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:T1 scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components-acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues.

  10. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement

    International Nuclear Information System (INIS)

    Saito, Masatoshi

    2007-01-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity--in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:Tl scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm 2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components - acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues

  11. Chemical mapping of pharmaceutical cocrystals using terahertz spectroscopic imaging.

    Science.gov (United States)

    Charron, Danielle M; Ajito, Katsuhiro; Kim, Jae-Young; Ueno, Yuko

    2013-02-19

    Terahertz (THz) spectroscopic imaging is a promising technique for distinguishing pharmaceuticals of similar molecular composition but differing crystal structures. Physicochemical properties, for instance bioavailability, are manipulated by altering a drug's crystal structure through methods such as cocrystallization. Cocrystals are molecular complexes having crystal structures different from those of their pure components. A technique for identifying the two-dimensional distribution of these alternate forms is required. Here we present the first demonstration of THz spectroscopic imaging of cocrystals. THz spectra of caffeine-oxalic acid cocrystal measured at low temperature exhibit sharp peaks, enabling us to visualize the cocrystal distribution in nonuniform tablets. The cocrystal distribution was clearly identified using THz spectroscopic data, and the cocrystal concentration was calculated with 0.3-1.3% w/w error from the known total concentration. From this result, THz spectroscopy allows quantitative chemical mapping of cocrystals and offers researchers and drug developers a new analytical tool.

  12. Measurement of shear wave speed dispersion in the placenta by transient elastography: A preliminary ex vivo study.

    Science.gov (United States)

    Simon, Emmanuel G; Callé, Samuel; Perrotin, Franck; Remenieras, Jean-Pierre

    2018-01-01

    Placental elasticity may be modified in women with placental insufficiency. Shear wave elastography (SWE) can measure this, using acoustic radiation force, but the safety of its use in pregnant women has not yet been demonstrated. Transient elastography (TE) is a safer alternative, but has not yet been applied to the placenta. Moreover, the dispersion of shear wave speed (SWS) as a function of frequency has received relatively little study for placental tissue, although it might improve the accuracy of biomechanical assessment. To explore the feasibility and reproducibility of TE for placental analysis, to compare the values of SWS and Young's modulus (YM) from TE and SWE, and to analyze SWS dispersion as a function of frequency ex vivo in normal placentas. Ten normal placentas were analyzed ex vivo by an Aixplorer ultrasound system as shear waves were generated by a vibrating plate and by using an Aixplorer system. The frequency analysis provided the value of the exponent n from a fractional rheological model applied to the TE method. We calculated intra- and interobserver agreement for SWS and YM with 95% prediction intervals, created Bland-Altman plots with 95% limits of agreement, and estimated the intraclass correlation coefficient (ICC). The mean SWS was 1.80 m/s +/- 0.28 (standard deviation) with the TE method at 50 Hz and 1.82 m/s +/-0.13 with SWE (P = 0.912). No differences were observed between the central and peripheral regions of placentas with either TE or SWE. With TE, the intraobserver ICC for SWS was 0.68 (0.50-0.82), and the interobserver ICC for SWS 0.65 (0.37-0.85). The mean parameter n obtained from the fractional rheological model was 1.21 +/- 0.12, with variable values of n for any given SWS. TE is feasible and reproducible on placentas ex vivo. The frequency analysis of SWS provides additional information about placental elasticity and appears to be able to distinguish differences between placental structures.

  13. [Measuring impairment of facial affects recognition in schizophrenia. Preliminary study of the facial emotions recognition task (TREF)].

    Science.gov (United States)

    Gaudelus, B; Virgile, J; Peyroux, E; Leleu, A; Baudouin, J-Y; Franck, N

    2015-06-01

    The impairment of social cognition, including facial affects recognition, is a well-established trait in schizophrenia, and specific cognitive remediation programs focusing on facial affects recognition have been developed by different teams worldwide. However, even though social cognitive impairments have been confirmed, previous studies have also shown heterogeneity of the results between different subjects. Therefore, assessment of personal abilities should be measured individually before proposing such programs. Most research teams apply tasks based on facial affects recognition by Ekman et al. or Gur et al. However, these tasks are not easily applicable in a clinical exercise. Here, we present the Facial Emotions Recognition Test (TREF), which is designed to identify facial affects recognition impairments in a clinical practice. The test is composed of 54 photos and evaluates abilities in the recognition of six universal emotions (joy, anger, sadness, fear, disgust and contempt). Each of these emotions is represented with colored photos of 4 different models (two men and two women) at nine intensity levels from 20 to 100%. Each photo is presented during 10 seconds; no time limit for responding is applied. The present study compared the scores of the TREF test in a sample of healthy controls (64 subjects) and people with stabilized schizophrenia (45 subjects) according to the DSM IV-TR criteria. We analysed global scores for all emotions, as well as sub scores for each emotion between these two groups, taking into account gender differences. Our results were coherent with previous findings. Applying TREF, we confirmed an impairment in facial affects recognition in schizophrenia by showing significant differences between the two groups in their global results (76.45% for healthy controls versus 61.28% for people with schizophrenia), as well as in sub scores for each emotion except for joy. Scores for women were significantly higher than for men in the population

  14. Spectroscopic and antimicrobial studies of polystyrene films under ...

    Indian Academy of Sciences (India)

    Spectroscopic and antimicrobial studies of polystyrene films under air plasma and He-Ne laser treatment ... The parameters such as (1) surface area by contact angle measurements, (2) quality of material before and after treatment by SEM and FTIR spectra and (3) material characterization by UV-vis spectra were studied.

  15. Velocity Curve Analysis of the Spectroscopic Binary Stars PV Pup ...

    Indian Academy of Sciences (India)

    are in good agreement with those obtained using the method of Lehmann-. Filhés. Key words. ... use their method to obtain the orbital elements of the four double-lined spectroscopic binary systems PV Pup, HD ... Observation shows that the photometric phase, φ, which is measured from the pho- tometric reference point ...

  16. A comparison of Hipparcos parallaxes with planetary nebulae spectroscopic distances

    NARCIS (Netherlands)

    Pottasch, [No Value; Acker, A

    1998-01-01

    The Hipparcos satellite has measured the parallax of a small sample of planetary nebulae. In this paper we consider the results for 3 planetary nebulae (PN) for which spectroscopic distances have also been determined from stellar gravities. These gravities in turn have been derived from profile

  17. Spectroscopic probes of vibrationally excited molecules at chemically significant energies

    Energy Technology Data Exchange (ETDEWEB)

    Rizzo, T.R. [Univ. of Rochester, NY (United States)

    1993-12-01

    This project involves the application of multiple-resonance spectroscopic techniques for investigating energy transfer and dissociation dynamics of highly vibrationally excited molecules. Two major goals of this work are: (1) to provide information on potential energy surfaces of combustion related molecules at chemically significant energies, and (2) to test theoretical modes of unimolecular dissociation rates critically via quantum-state resolved measurements.

  18. Methodological development for 87Sr/86Sr measurement in olive oil and preliminary discussion of its use for geographical traceability of PDO Nîmes (France).

    Science.gov (United States)

    Medini, Salim; Janin, Myriam; Verdoux, Patrick; Techer, Isabelle

    2015-03-15

    The lack of a geographical identification protocol for olive oils can lead to fraud and health risks. As some works call for Sr isotopes for the geographical identification of agri-food products, this study focus on the feasibility of extracting Sr from olive oils for isotopic measurements by TIMS. In fact, existing protocols for purification of Sr are unsuitable for lipid matrix. The defined protocol is applied to samples of PDO Nîmes olive oil. The accuracy of the extraction procedure is tested against isotopic standards. The values obtained are in conformity with NIST certified values. This consistency demonstrates that no modification of (87)Sr/(86)Sr ratio is brought about by this protocol. Consequently, the method is preliminary used on PDO Nîmes and Moroccan oils to evaluate the feasibility of a discriminant Sr signature on the two geographical products. This study provides promising results for the geographical discrimination and identification of PDO olive oils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Preliminary assessment, by means of Radon exhalation rate measurements, of the bio-sustainability of microwave treatment to eliminate biodeteriogens infesting stone walls of monumental historical buildings.

    Science.gov (United States)

    Mancini, S.; Caliendo, E.; Guida, M.; Bisceglia, B.

    2017-10-01

    The main purpose of the work described in this paper has been to establish the protocol for a new non-disruptive technique of intervention, based on microwave treatment, for cleaning operations on monumental historical buildings, to eliminate biodeteriogens infesting stones. Non-destructive methods in the cleaning operations, should not only preserve the physical integrity, the chemical-mineralogical and structural identity of materials, but, when the exhalation of pollutant agents (like for example Radon gas) from building materials is considered, also, make the indoor air quality (IAQ) levels healthy. Therefore, one of the main steps of the protocol proposed in this paper is concerned with the assessment of the Radon exhalation rate in order to verify that microwave treatments do not increase the Radon naturally exhalated by building materials. In this paper, the preliminary results of the Radon measurements performed on two different type of tuff samples (grey tuff and yellow tuff), typical of the Italian traditional construction heritage, with the E-PERM passive technique at the Environmental Radioactivity Laboratory (Amb.Ra.), University of Salerno, Italy, ISO 9001:2008 certified, are summarized.

  20. Preliminary development of a new individualised questionnaire measuring quality of life in older men with age-related hormonal decline: the A-RHDQoL

    Directory of Open Access Journals (Sweden)

    Giannoulis Manthos

    2003-10-01

    Full Text Available Abstract Background There is increasing interest in hormone replacement therapy to improve health and quality of life (QoL of older men with age-related decline in hormone levels. This paper reports the preliminary development and evaluation of the psychometric properties of a new individualised questionnaire, the A-RHDQoL, measuring perceived impact of age-related hormonal decline on QoL of older men. A-RHDQoL design was based on the HDQoL for people with growth hormone (GH deficiency and the ADDQoL (for diabetes. Methods Internal consistency reliability and some aspects of validity of the A-RHDQoL were investigated in a cross-sectional survey of 128 older men (age range: 64 – 80 yrs, being screened for inclusion in a trial of GH and testosterone (T replacement, and who completed the A-RHDQoL once. Respondents rated personally applicable life domains for importance and impact of their hormonal decline. A single overview item measured present QoL. Serum levels of Insulin-like Growth Factor-I and total T were measured. Results Of the 24 A-RHDQoL domains, 21 were rated as relevant and important for older men. All domains were perceived as negatively impacted by hormonal decline. The most negatively impacted domains were: memory (-4.54 ± 3.02, energy (-4.44 ± 2.49, sex life (-4.34 ± 3.08 and physical stamina (-4.29 ± 2.41, (maximum range -9 to +9. The shorter 21-domain A-RHDQoL had high internal consistency reliability (Cronbach's alpha coefficient = 0.935, N = 103 and applicable domains could be weighted and summed into an overall Average Weighted Impact score. The questionnaire was acceptable to the majority of respondents and content validity was good. The single overview item measuring present QoL correlated significantly with total T levels [r = 0.26, p Conclusion The new 21-item A-RHDQoL is an individualised questionnaire measuring perceived impact of age-related hormonal decline on the QoL of older men. The internal consistency

  1. sick: The Spectroscopic Inference Crank

    Science.gov (United States)

    Casey, Andrew R.

    2016-03-01

    There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal

  2. SICK: THE SPECTROSCOPIC INFERENCE CRANK

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Andrew R., E-mail: arc@ast.cam.ac.uk [Institute of Astronomy, University of Cambridge, Madingley Road, Cambdridge, CB3 0HA (United Kingdom)

    2016-03-15

    There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal

  3. SICK: THE SPECTROSCOPIC INFERENCE CRANK

    International Nuclear Information System (INIS)

    Casey, Andrew R.

    2016-01-01

    There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal

  4. Spectroscopic characterization of low dose rate brachytherapy sources

    Science.gov (United States)

    Beach, Stephen M.

    The low dose rate (LDR) brachytherapy seeds employed in permanent radioactive-source implant treatments usually use one of two radionuclides, 125I or 103Pd. The theoretically expected source spectroscopic output from these sources can be obtained via Monte Carlo calculation based upon seed dimensions and materials as well as the bare-source photon emissions for that specific radionuclide. However the discrepancies resulting from inconsistent manufacturing of sources in comparison to each other within model groups and simplified Monte Carlo calculational geometries ultimately result in undesirably large uncertainties in the Monte Carlo calculated values. This dissertation describes experimentally attained spectroscopic outputs of the clinically used brachytherapy sources in air and in liquid water. Such knowledge can then be applied to characterize these sources by a more fundamental and metro logically-pure classification, that of energy-based dosimetry. The spectroscopic results contained within this dissertation can be utilized in the verification and benchmarking of Monte Carlo calculational models of these brachytherapy sources. This body of work was undertaken to establish a usable spectroscopy system and analysis methods for the meaningful study of LDR brachytherapy seeds. The development of a correction algorithm and the analysis of the resultant spectroscopic measurements are presented. The characterization of the spectrometer and the subsequent deconvolution of the measured spectrum to obtain the true spectrum free of any perturbations caused by the spectrometer itself is an important contribution of this work. The approach of spectroscopic deconvolution that was applied in this work is derived in detail and it is applied to the physical measurements. In addition, the spectroscopically based analogs to the LDR dosimetry parameters that are currently employed are detailed, as well as the development of the theory and measurement methods to arrive at these

  5. Large aperture Fizeau interferometer commissioning and preliminary measurements of a long x-ray mirror at European X-ray Free Electron Laser

    Energy Technology Data Exchange (ETDEWEB)

    Vannoni, M., E-mail: maurizio.vannoni@xfel.eu; Freijo Martín, I. [European XFEL GmbH, Albert-Einstein-Ring 19, 22761 Hamburg (Germany)

    2016-05-15

    The European XFEL (X-ray Free Electron Laser) is a large facility under construction in Hamburg, Germany. It will provide a transversally fully coherent x-ray radiation with outstanding characteristics: high repetition rate (up to 2700 pulses with a 0.6 ms long pulse train at 10 Hz), short wavelength (down to 0.05 nm), short pulse (in the femtoseconds scale), and high average brilliance (1.6 ⋅ 10{sup 25} (photons s{sup −1} mm{sup −2} mrad{sup −2})/0.1% bandwidth). The beam has very high pulse energy; therefore, it has to be spread out on a relatively long mirror (about 1 m). Due to the very short wavelength, the mirrors need to have a high quality surface on their entire length, and this is considered very challenging even with the most advanced polishing methods. In order to measure the mirrors and to characterize their interaction with the mechanical mount, we equipped a metrology laboratory with a large aperture Fizeau interferometer. The system is a classical 100 mm diameter commercial Fizeau, with an additional expander providing a 300 mm diameter beam. Despite the commercial nature of the system, special care has been taken in the polishing of the reference flats and in the expander quality. We report the first commissioning of the instrument, its calibration, and performance characterization, together with some preliminary results with the measurement of a 950 mm silicon substrate. The intended application is to characterize the final XFEL mirrors with nanometer accuracy.

  6. Infrared Spectroscopic Imaging: The Next Generation

    Science.gov (United States)

    Bhargava, Rohit

    2013-01-01

    Infrared (IR) spectroscopic imaging seemingly matured as a technology in the mid-2000s, with commercially successful instrumentation and reports in numerous applications. Recent developments, however, have transformed our understanding of the recorded data, provided capability for new instrumentation, and greatly enhanced the ability to extract more useful information in less time. These developments are summarized here in three broad areas— data recording, interpretation of recorded data, and information extraction—and their critical review is employed to project emerging trends. Overall, the convergence of selected components from hardware, theory, algorithms, and applications is one trend. Instead of similar, general-purpose instrumentation, another trend is likely to be diverse and application-targeted designs of instrumentation driven by emerging component technologies. The recent renaissance in both fundamental science and instrumentation will likely spur investigations at the confluence of conventional spectroscopic analyses and optical physics for improved data interpretation. While chemometrics has dominated data processing, a trend will likely lie in the development of signal processing algorithms to optimally extract spectral and spatial information prior to conventional chemometric analyses. Finally, the sum of these recent advances is likely to provide unprecedented capability in measurement and scientific insight, which will present new opportunities for the applied spectroscopist. PMID:23031693

  7. Spectroscopic studies of pulsed-power plasmas

    International Nuclear Information System (INIS)

    Maron, Y.; Arad, R.; Dadusc, G.; Davara, G.; Duvall, R.E.; Fisher, V.; Foord, M.E.; Fruchtman, A.; Gregorian, L.; Krasik, Ya.

    1993-01-01

    Recently developed spectroscopic diagnostic techniques are used to investigate the plasma behavior in a Magnetically Insulated Ion Diode, a Plasma Opening Switch, and a gas-puffed Z-pinch. Measurements with relatively high spectral, temporal, and spatial resolutions are performed. The particle velocity and density distributions within a few tens of microns from the dielectric-anode surface are observed using laser spectroscopy. Collective fluctuating electric fields in the plasma are inferred from anisotropic Stark broadening. For the Plasma Opening Switch experiment, a novel gaseous plasma source was developed which is mounted inside the high-voltage inner conductor. The properties of this source, together with spectroscopic observations of the electron density and particle velocities of the injected plasma, are described. Emission line intensities and spectral profiles give the electron kinetic energies during the switch operation and the ion velocity distributions. Secondary plasma ejection from the electrodes is also studied. In the Z-pinch experiment, spectral emission-line profiles are studied during the implosion phase. Doppler line shifts and widths yield the radial velocity distributions for various charge states in various regions of the plasma. Effects of plasma ejection from the cathode are also studied

  8. Spectroscopic enhancement in nanoparticles embedded glasses

    Energy Technology Data Exchange (ETDEWEB)

    Sahar, M. R., E-mail: mrahim057@gmail.com; Ghoshal, S. K., E-mail: mrahim057@gmail.com [Advanced Optical Material Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310, Skudai, Johor Bahru, Johor (Malaysia)

    2014-09-25

    This presentation provides an overview of the recent progress in the enhancement of the spectroscopic characteristics of the glass embedded with nanoparticles (NPs). Some of our research activities with few significantly new results are highlighted and facilely analyzed. The science and technology dealing with the manipulation of the physical properties of rare earth doped inorganic glasses by embedding metallic NPs or nanoclusters produce the so-called 'nanoglass'. Meanwhile, the spectroscopic enhancement relates the intensity of the luminescence measured at certain transition. The enhancement which expectedly due to the 'plasmonics wave' (referring to the coherent coupling of photons to free electron oscillations called plasmon) occurs at the interface between a conductor and a dielectric. Plasmonics being an emerging concept in advanced optical material of nanophotonics has given this material the ability to exploit the optical response at nanoscale and opened up a new avenue in metal-based glass optics. There is a vast array of plasmonic NPs concepts yet to be explored, with applications spanning solar cells, (bio) sensing, communications, lasers, solid-state lighting, waveguides, imaging, optical data transfer, display and even bio-medicine. Localized surface plasmon resonance (LSPR) can enhance the optical response of nanoglass by orders of magnitude as observed. The luminescence enhancement and surface enhanced Raman scattering (SERS) are new paradigm of research. The enhancement of luminescence due to the influence of metallic NPs is the recurring theme of this paper.

  9. The BAT AGN Spectroscopic Survey (BASS)

    Science.gov (United States)

    Koss, Michael

    2017-08-01

    We present the Swift BAT AGN Spectroscopic Survey (BASS) and discus the first four papers. The catalog represents an unprecedented census of hard-X-ray selected AGN in the local universe, with ~90% of sources at zpast studies. Consistent with previous surveys, we find an increase in the fraction of un-obscured (type 1) AGN, as measured from broad Hbeta and Halpha, with increasing 14-195 keV and 2-10 keV luminosity. We find the FWHM of the emission lines to show broad agreement with the X-ray obscuration measurements. Compared to narrow line AGN in the SDSS, the X-ray selected AGN in our sample with emission lines have a larger fraction of dustier galaxies suggesting these types of galaxies are missed in optical AGN surveys using emission line diagnostics.

  10. Spectroscopic and chemometric exploration of food quality

    DEFF Research Database (Denmark)

    Pedersen, Dorthe Kjær

    2002-01-01

    and multi-way chemometrics demonstrated the potential for screening of environmental contamination in complex food samples. Significant prediction models were established with correlation coefficients in the range from r = 0.69 to r = 0.97 for dioxin. Further development of the fluorescence measurements......The desire to develop non-invasive rapid measurements of essential quality parameters in foods is the motivation of this thesis. Due to the speed and noninvasive properties of spectroscopic techniques, they have potential as on-line or atline methods and can be employed in the food industry...... in order to control the quality of the end product and to continuously monitor the production. In this thesis, the possibilities and limitations of the application of spectroscopy and chemometrics in rapid control of food quality are discussed and demonstrated by the examples in the eight included...

  11. Single nanoparticle tracking spectroscopic microscope

    Science.gov (United States)

    Yang, Haw [Moraga, CA; Cang, Hu [Berkeley, CA; Xu, Cangshan [Berkeley, CA; Wong, Chung M [San Gabriel, CA

    2011-07-19

    A system that can maintain and track the position of a single nanoparticle in three dimensions for a prolonged period has been disclosed. The system allows for continuously imaging the particle to observe any interactions it may have. The system also enables the acquisition of real-time sequential spectroscopic information from the particle. The apparatus holds great promise in performing single molecule spectroscopy and imaging on a non-stationary target.

  12. Spectroscopic amplifier for pin diode

    International Nuclear Information System (INIS)

    Alonso M, M. S.; Hernandez D, V. M.; Vega C, H. R.

    2014-10-01

    The photodiode remains the basic choice for the photo-detection and is widely used in optical communications, medical diagnostics and field of corpuscular radiation. In detecting radiation it has been used for monitoring radon and its progeny and inexpensive spectrometric systems. The development of a spectroscopic amplifier for Pin diode is presented which has the following characteristics: canceler Pole-Zero (P/Z) with a time constant of 8 μs; constant gain of 57, suitable for the acquisition system; 4th integrator Gaussian order to waveform change of exponential input to semi-Gaussian output and finally a stage of baseline restorer which prevents Dc signal contribution to the next stage. The operational amplifier used is the TLE2074 of BiFET technology of Texas Instruments with 10 MHz bandwidth, 25 V/μs of slew rate and a noise floor of 17 nv/(Hz)1/2. The integrated circuit has 4 operational amplifiers and in is contained the total of spectroscopic amplifier that is the goal of electronic design. The results show like the exponential input signal is converted to semi-Gaussian, modifying only the amplitude according to the specifications in the design. The total system is formed by the detector, which is the Pin diode, a sensitive preamplifier to the load, the spectroscopic amplifier that is what is presented and finally a pulse height analyzer (Mca) which is where the spectrum is shown. (Author)

  13. Synthesis of a ruthenium(II) bipyridyl complex coordinated by a functionalized Schiff base ligand: characterization, spectroscopic and isothermal titration calorimetry measurements of M2+ binding and sensing (M2+=Ca2+, Mg2+).

    Science.gov (United States)

    Dixit, Namrata; Mishra, Lallan; Mustafi, Sourajit M; Chary, Kandala V R; Houjou, Hirohiko

    2009-07-01

    Bis-[methylsalicylidine-4'benzoic acid]-ethylene (LH2) complexed with cis-Ru(bpy)2Cl(2).2H2O provides a complex of composition [Ru(bpy)2L].2NH4PF6 (1), which has been characterized spectroscopically. Its binding behaviour towards Mg2+ and Ca2+ ions is monitored using 1H NMR titration, isothermal titration calorimetry (ITC) and luminescence microscopy. The luminescent ruthenium complex binds Ca2+ in a more selective manner as compared to Mg2+.

  14. Studies of quenched disorder in La{sub 0.7}Ca{sub 0.3}MnO{sub 3}-type CMR manganite system from magnetic, transport and positron annihilation spectroscopic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Chattopadhyay, S. [Department of Physics, Taki Government College, Taki 743429 (India); Department of Solid State Physics, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700 032 (India); Sarkar, A. [Department of Physics, Bangabasi Morning College, 19 Rajkumar Chakraborty Sarani, Kolkata 700009 (India); Pal, Sudipta [Department of Physics, Krishnagar Womens College, Krishnagar 741101 (India); Kulkarni, S.D. [Physical and Materials Chemistry Division, National Chemical Laboratory, Pune 411008 (India); Joy, P.A. [Physical and Materials Chemistry Division, National Chemical Laboratory, Pune 411008 (India); Chaudhuri, B.K. [Department of Solid State Physics, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700 032 (India)]. E-mail: sspbkc@rediffmail.com

    2007-08-01

    The effects of quenched disorder on the structural, transport and magnetic properties of the La{sub 0.7}Ca{sub 0.3}MnO{sub 3}-type colossal magnetoresistive (CMR) sample have been reported. Temperature-dependent resistivity and magnetization data of the quenched sample revealed interesting changes from those of the usual slow-cooled sample. This is attributed to the defects created in the quenched sample and confirmed from the X-ray diffraction (XRD) and positron annihilation spectroscopic studies.

  15. Nuclear spectroscopic studies

    Energy Technology Data Exchange (ETDEWEB)

    Bingham, C.R.; Guidry, M.W.; Riedinger, L.L.; Sorensen, S.P.

    1993-02-08

    The Nuclear Physics group at the University of Tennessee, Knoxville is involved in several aspects of heavy-ion physics including both nuclear structure and reaction mechanisms. While our main emphasis is on experimental problems involving heavy-ion accelerators, we have maintained a strong collaboration with several theorists in order to best pursue the physics of our measurements. During the last year we have led several experiments at the Holifield Heavy Ion Research Facility and participated in others at Argonne National Laboratory. Also, we continue to be very active in the collaboration to study ultra-relativistic heavy ion physics utilizing the SPS accelerator at CERN in Geneva, Switzerland and in a RHIC detector R D project. Our experimental work is in four broad areas: (1) the structure of nuclei at high angular momentum, (2) heavy-ion induced transfer reactions, (3) the structure of nuclei far from stability, and (4) ultra-relativistic heavy-ion physics. The results of studies in these particular areas will be described in this document in sections IIA, IIB, IIC, and IID, respectively. Areas (1), (3), and (4) concentrate on the structure of nuclear matter in extreme conditions of rotational motion, imbalance of neutrons and protons, or very high temperature and density. Area (2) pursues the transfer of nucleons to states with high angular momentum, both to learn about their structure and to understand the transfer of particles, energy, and angular momentum in collisions between heavy ions. An important component of our program is the strong emphasis on the theoretical aspects of nuclear structure and reactions.

  16. Nuclear spectroscopic studies

    International Nuclear Information System (INIS)

    Bingham, C.R.; Guidry, M.W.; Riedinger, L.L.; Sorensen, S.P.

    1988-01-01

    The Nuclear Physics group at the University of Tennessee, Knoxville is involved in several aspects of heavy-ion physics including both nuclear structure and reaction mechanisms. While our main emphasis is on experimental problems involving heavy-ion accelerators, we have maintained a strong collaboration with several theorists in order to best pursue the physics of our measurements. During the last year we have led experiments at the Holifield Heavy Ion Research Facility, the SuperHILAC at Berkeley, and Chalk River Tandem Accelerator. Also, we have joined a collaboration to study ultra-relativistic heavy ion physics and one of our group has spent all of 1987 at CERN to work on the WA80 experiment. Our experimental work is in four broad areas: (1) the structure of nuclei at high angular momentum, (2) heavy-ion induced transfer reactions, (3) the structure of nuclei far from stability, and (4) ultra-relativistic heavy-ion physics. These results will be described in this document in sections 2A, 2B, 2C, and 2D, respectively. Areas (1), (3), and (4) concentrate on the structure of nuclear matter in extreme conditions of rotational motion, imbalance of neutrons and protons or very high temperature and density. Area (2) pursues the transfer of nucleons to states with high angular momentum, both to learn about their structure and to understand the transfer of particles, energy and angular momentum in collisions between heavy ions. An important component of our program is the strong emphasis on the theoretical aspects of nuclear structure and reactions

  17. Nuclear spectroscopic studies

    International Nuclear Information System (INIS)

    Bingham, C.R.; Guidry, M.W.; Riedinger, L.L.; Sorensen, S.P.

    1991-01-01

    The Nuclear Physics group at the University of Tennessee, Knoxville is involved in several aspects of heavy-ion physics including both nuclear structure and reaction mechanisms. While our main emphasis is on experimental problems involving heavy-ion accelerators, we have maintained a strong collaboration with several theorists in order to best pursue the physics of our measurements. During the last year we have led experiments at the Holifield Heavy Ion Research Facility, the SuperHILAC at Berkeley, and Chalk River Tandem Accelerator. Also, we have joined a collaboration to study ultra-relativistic heavy ion physics and one of our group has spent all of 1987 at CERN to work on the WA80 experiment. Our experimental work is in four broad areas: (1) the structure of nuclei at high angular momentum, (2) heavy-ion induced transfer reactions, (3) the structure of nuclei far from stability, and (4) ultra-relativistic heavy-ion physics. These results will be described in this document in sections IIA, IIB, and IID, respectively. Areas (1), (3), and (4) concentrate on the structure of nuclear matter in extreme conditions of rotational motion, imbalance of neutrons and protons, or very high temperature and density. Area (2) pursues the transfer of nucleons to states with high angular momentum, both to learn about their structure and to understand the transfer of particles, energy and angular momentum in collisions between heavy ions. An important component of our program is the strong emphasis on the theoretical aspects of nuclear structure and reactions

  18. Nuclear spectroscopic studies

    International Nuclear Information System (INIS)

    Bingham, C.R.; Guidry, M.W.; Riedinger, L.L.; Sorensen, S.P.

    1993-01-01

    The Nuclear Physics group at the University of Tennessee, Knoxville is involved in several aspects of heavy-ion physics including both nuclear structure and reaction mechanisms. While our main emphasis is on experimental problems involving heavy-ion accelerators, we have maintained a strong collaboration with several theorists in order to best pursue the physics of our measurements. During the last year we have led several experiments at the Holifield Heavy Ion Research Facility and participated in others at Argonne National Laboratory. Also, we continue to be very active in the collaboration to study ultra-relativistic heavy ion physics utilizing the SPS accelerator at CERN in Geneva, Switzerland and in a RHIC detector R ampersand D project. Our experimental work is in four broad areas: (1) the structure of nuclei at high angular momentum, (2) heavy-ion induced transfer reactions, (3) the structure of nuclei far from stability, and (4) ultra-relativistic heavy-ion physics. The results of studies in these particular areas will be described in this document in sections IIA, IIB, IIC, and IID, respectively. Areas (1), (3), and (4) concentrate on the structure of nuclear matter in extreme conditions of rotational motion, imbalance of neutrons and protons, or very high temperature and density. Area (2) pursues the transfer of nucleons to states with high angular momentum, both to learn about their structure and to understand the transfer of particles, energy, and angular momentum in collisions between heavy ions. An important component of our program is the strong emphasis on the theoretical aspects of nuclear structure and reactions

  19. Medida Interpessoal de Psicopatia (IM-P: estudo preliminar no contexto brasileiro Interpersonal Measure of Psychopathy (IM-P: preliminary study in the Brazilian context

    Directory of Open Access Journals (Sweden)

    Tárcia Rita Davoglio

    2011-01-01

    Full Text Available INTRODUÇÃO: A observação direta do comportamento interpessoal é um recurso importante na descrição e diagnóstico da personalidade psicopática. A Medida Interpessoal de Psicopatia (Interpersonal Measure of Psychopathy, IM-P é um instrumento psicométrico composto por 21 itens, desenvolvido para ser utilizado em associação com outras escalas de avaliação da psicopatia. Foca-se, especificamente, nos comportamentos interpessoais e aspectos não verbais evidentes na interação do entrevistador com indivíduos que apresentam características psicopáticas. OBJETIVO: Descrever resultados preliminares sobre a investigação de aspectos interpessoais da psicopatia mediante a utilização da IM-P, incluindo as etapas de tradução/adaptação e avaliação de confiabilidade interavaliadores da IM-P, em uma amostra de adolescentes brasileiros. MÉTODO: Trata-se de estudo transversal, descritivo e correlacional realizado com 20 adolescentes masculinos cumprindo medida socioeducativa com privação de liberdade na Região Metropolitana de Porto Alegre (RS. Após os procedimentos de tradução da escala, treinamento dos pesquisadores e teste piloto por meio de uma entrevista semiestruturada, a IM-P foi pontuada por três juízes independentes. RESULTADOS: Os resultados estatísticos, obtidos através do coeficiente de concordância de Kendall, revelaram grau de concordância interavaliadores elevado e satisfatório para os escores totais da IM-P (W = 0,84; p INTRODUCTION: The direct observation of interpersonal behaviors is an important resource in the description and diagnosis of the psychopathic personality. The Interpersonal Measure of Psychopathy (IM-P is a psychometric instrument comprised of 21 items, designed to be applied in association with other instruments that also evaluate psychopaths. It focuses specifically on interpersonal and non-verbal behaviors that become evident during the interaction between the interviewer and individuals

  20. Poster — Thur Eve — 24: Commissioning and preliminary measurements using an Attix-style free air ionization chamber for air kerma measurements on the BioMedical Imaging and Therapy beamlines at the Canadian Light Source

    International Nuclear Information System (INIS)

    Anderson, D; McEwen, M; Shen, H; Siegbahn, EA; Fallone, BG; Warkentin, B

    2014-01-01

    Synchrotron facilities, including the Canadian Light Source (CLS), provide opportunities for the development of novel imaging and therapy applications. A vital step progressing these applications toward clinical trials is the availability of accurate dosimetry. In this study, a refurbished Attix-style (cylindrical) free air chamber (FAC) is tested and used for preliminary air kerma measurements on the two BioMedical Imaging and Therapy (BMIT) beamlines at the CLS. The FAC consists of a telescoping chamber that relies on a difference measurement of collected charge in expanded and collapsed configurations. At the National Research Council's X-ray facility, a Victoreen Model 480 FAC was benchmarked against two primary standard FACs. The results indicated an absolute accuracy at the 0.5% level for energies between 60 and 150 kVp. A series of measurements were conducted on the small, non-uniform X-ray beams of the 05B1-1 (∼8 – 100 keV) and 05ID-2 (∼20 – 200 keV) beamlines for a variety of energies, filtrations and beam sizes. For the 05B1-1 beam with 1.1 mm of Cu filtration, recombination corrections of less than 5 % could only be achieved for field sizes no greater than 0.5 mm × 0.6 mm (corresponding to an air kerma rate of ∼ 57 Gy/min). Ionic recombination thus presents a significant challenge to obtaining accurate air kerma rate measurements using this FAC in these high intensity beams. Future work includes measurements using a smaller aperture to sample a smaller and thus more uniform beam area, as well as experimental and Monte Carlo-based investigation of correction factors

  1. Normal-incidence spectroscopic ellipsometry for critical dimension monitoring

    International Nuclear Information System (INIS)

    Huang, Hsu-Ting; Kong, Wei; Terry, Fred Lewis

    2001-01-01

    In this letter, we show that normal-incidence spectroscopic ellipsometry can be used for high-accuracy topography measurements on surface relief gratings. We present both experimental and theoretical results which show that spectroscopic ellipsometry or reflectance-difference spectroscopy at near-normal incidence coupled with vector diffraction theory for data analysis is capable of high-accuracy critical dimension (CD), feature height, and sidewall angle measurements in the extreme submicron regime. Quantitative comparisons of optical and cross-sectional scanning electron microscopy (SEM) topography measurements from a number of 350 nm line/space reactive-ion-etched Si gratings demonstrate the strong potential for in situ etching monitoring. This technique can be used for both ex situ and in situ applications and has the potential to replace the use of CD-SEM measurements in some applications. [copyright] 2001 American Institute of Physics

  2. The Tiptop coal-mine fire, Kentucky: Preliminary investigation of the measurement of mercury and other hazardous gases from coal-fire gas vents

    Energy Technology Data Exchange (ETDEWEB)

    Hower, James C.; Henke, Kevin [University of Kentucky Center for Applied Energy Research, Lexington, KY 40511 (United States); O' Keefe, Jennifer M.K. [Morehead State University, Morehead, KY 40351 (United States); Engle, Mark A. [U.S. Geological Survey, Reston, VA 20192 (United States); Blake, Donald R. [Department of Chemistry, University of California - Irvine, Irvine, CA 92697 (United States); Stracher, Glenn B. [East Georgia College, Swainsboro, GA 30401 (United States)

    2009-10-01

    The Tiptop underground coal-mine fire in the Skyline coalbed of the Middle Pennsylvanian Breathitt Formation was investigated in rural northern Breathitt County, Kentucky, in May 2008 and January 2009, for the purpose of determining the concentrations of carbon dioxide (CO{sub 2}), carbon monoxide (CO), and mercury (Hg) in the vent and for measuring gas-vent temperatures. At the time of our visits, concentrations of CO{sub 2} peaked at 2.0% and > 6.0% (v/v) and CO at 600 ppm and > 700 ppm during field analysis in May 2008 and January 2009, respectively. For comparison, these concentrations exceed the U.S. Occupational Safety and Health Administration (OSHA) eight-hour safe exposure limits (0.5% CO{sub 2} and 50 ppm CO), although the site is not currently mined. Mercury, as Hg{sup 0}, in excess of 500 and 2100 {mu}g/m{sup 3}, in May and January, respectively, in the field, also exceeded the OSHA eight-hour exposure limit (50 {mu}g/m{sup 3}). Carbonyl sulfide, dimethyl sulfide, carbon disulfide, and a suite of organic compounds were determined at two vents for the first sampling event. All gases are diluted by air as they exit and migrate away from a gas vent, but temperature inversions and other meteorological conditions could lead to unhealthy concentrations in the nearby towns. Variation in gas temperatures, nearly 300 C during the January visit to the fire versus < 50 C in May, demonstrates the large temporal variability in fire intensity at the Tiptop mine. These preliminary results suggest that emissions from coal fires may be important, but additional data are required that address the reasons for significant variations in the composition, flow, and temperature of vent gases. (author)

  3. Determination of three-dimensional stress orientations in the Wenchuan earthquake Fault Scientific Drilling (WFSD) hole-1: A preliminary result by anelastic strain recovery measurements of core samples

    Science.gov (United States)

    Cui, J.; Lin, W.; Wang, L.; Tang, Z.; Sun, D.; Gao, L.; Wang, W.

    2010-12-01

    A great and destructive earthquake (Ms 8.0; Mw 7.9), Wunchuan earthquake struck on the Longmen Shan foreland trust zone in Sichuan province, China on 12 May 2008 (Xu et al., 2008; Episodes, Vol.31, pp.291-301). As a rapid response scientific drilling project, Wenchuan earthquake Fault Scientific Drilling (WFSD) started on 6 November 2008 shorter than a half of year from the date of earthquake main shock. The first pilot borehole (hole-1) has been drilled to the target depth (measured depth 1201 m MD, vertical depth 1179 m) at Hongkou, Dujianyan, Sichuan and passed through the main fault of the earthquake around 589 m MD. We are trying to determine three dimensional in-situ stress states in the WFSD boreholes by a core-based method, anelastic strain recovery (ASR) method (Lin et al., 2006; Tectonophysics, Vol4.26, pp.221-238). This method has been applied in several scientific drilling projects (TCDP: Lin et al., 2007; TAO, Vol.18, pp.379-393; NanTtoSEIZE: Byrne et al., 2009; GRL, Vol.36, L23310). These applications confirm the validity of using the ASR technique in determining in situ stresses by using drilled cores. We collected total 15 core samples in a depth range from 340 m MD to 1180 m MD, approximately for ASR measurements. Anelastic normal strains, measured every ten minutes in nine directions, including six independent directions, were used to calculate the anelastic strain tensors. The data of the ASR tests conducted at hole-1 is still undergoing analysis. As a tentative perspective, more than 10 core samples showed coherent strain recovery over one - two weeks. However, 2 or 3 core samples cannot be re-orientated to the global system. It means that we cannot rink the stress orientation determined by the core samples to geological structure. Unfortunately, a few core samples showed irregular strain recovery and were not analyzed further. The preliminary results of ASR tests at hole-1 show the stress orientations and stress regime changes a lot with the

  4. Catalyst Architecture for Stable Single Atom Dispersion Enables Site-Specific Spectroscopic and Reactivity Measurements of CO Adsorbed to Pt Atoms, Oxidized Pt Clusters, and Metallic Pt Clusters on TiO2.

    Science.gov (United States)

    DeRita, Leo; Dai, Sheng; Lopez-Zepeda, Kimberly; Pham, Nicholas; Graham, George W; Pan, Xiaoqing; Christopher, Phillip

    2017-10-11

    Oxide-supported precious metal nanoparticles are widely used industrial catalysts. Due to expense and rarity, developing synthetic protocols that reduce precious metal nanoparticle size and stabilize dispersed species is essential. Supported atomically dispersed, single precious metal atoms represent the most efficient metal utilization geometry, although debate regarding the catalytic activity of supported single precious atom species has arisen from difficulty in synthesizing homogeneous and stable single atom dispersions, and a lack of site-specific characterization approaches. We propose a catalyst architecture and characterization approach to overcome these limitations, by depositing ∼1 precious metal atom per support particle and characterizing structures by correlating scanning transmission electron microscopy imaging and CO probe molecule infrared spectroscopy. This is demonstrated for Pt supported on anatase TiO 2 . In these structures, isolated Pt atoms, Pt iso , remain stable through various conditions, and spectroscopic evidence suggests Pt iso species exist in homogeneous local environments. Comparing Pt iso to ∼1 nm preoxidized (Pt ox ) and prereduced (Pt metal ) Pt clusters on TiO 2 , we identify unique spectroscopic signatures of CO bound to each site and find CO adsorption energy is ordered: Pt iso ≪ Pt metal atoms bonded to TiO 2 and that Pt iso exhibits optimal reactivity because every atom is exposed for catalysis and forms an interfacial site with TiO 2 . This approach should be generally useful for studying the behavior of supported precious metal atoms.

  5. Spectroscopic studies of hydrogen atom and molecule collisions: Performance report

    International Nuclear Information System (INIS)

    Kielkopf, J.

    1986-01-01

    This research is concerned with spectroscopic measurements of collisions in atomic and molecular hydrogen in order to clarify the basic physical processes that take place during radiative collisions and to provide experimental values for systems where the theoretical analysis is tractable. To this end, we proposed to measure from the cores to the far wings the profiles of the spectral lines of atomic hydrogen broadened by molecular hydrogen and noble gases, and to study energy transfer in the atom and molecule

  6. Spectroscopic Needs for Imaging Dark Energy Experiments

    International Nuclear Information System (INIS)

    Newman, Jeffrey A.; Abate, Alexandra; Abdalla, Filipe B.; Allam, Sahar; Allen, Steven W.; Ansari, Reza; Bailey, Stephen; Barkhouse, Wayne A.; Beers, Timothy C.; Blanton, Michael R.; Brodwin, Mark; Brownstein, Joel R.; Brunner, Robert J.; Carrasco-Kind, Matias; Cervantes-Cota, Jorge; Chisari, Nora Elisa; Colless, Matthew; Coupon, Jean; Cunha, Carlos E.; Frye, Brenda L.; Gawiser, Eric J.; Gehrels, Neil; Grady, Kevin; Hagen, Alex; Hall, Patrick B.; Hearin, Andrew P.; Hildebrandt, Hendrik; Hirata, Christopher M.; Ho, Shirley; Huterer, Dragan; Ivezic, Zeljko; Kneib, Jean-Paul; Kruk, Jeffrey W.; Lahav, Ofer; Mandelbaum, Rachel; Matthews, Daniel J.; Miquel, Ramon; Moniez, Marc; Moos, H. W.; Moustakas, John; Papovich, Casey; Peacock, John A.; Rhodes, Jason; Ricol, Jean-Stepane; Sadeh, Iftach; Schmidt, Samuel J.; Stern, Daniel K.; Tyson, J. Anthony; Von der Linden, Anja; Wechsler, Risa H.; Wood-Vasey, W. M.; Zentner, A.

    2015-01-01

    Ongoing and near-future imaging-based dark energy experiments are critically dependent upon photometric redshifts (a.k.a. photo-z's): i.e., estimates of the redshifts of objects based only on flux information obtained through broad filters. Higher-quality, lower-scatter photo-z's will result in smaller random errors on cosmological parameters; while systematic errors in photometric redshift estimates, if not constrained, may dominate all other uncertainties from these experiments. The desired optimization and calibration is dependent upon spectroscopic measurements for secure redshift information; this is the key application of galaxy spectroscopy for imaging-based dark energy experiments. Hence, to achieve their full potential, imaging-based experiments will require large sets of objects with spectroscopically-determined redshifts, for two purposes: Training: Objects with known redshift are needed to map out the relationship between object color and z (or, equivalently, to determine empirically-calibrated templates describing the rest-frame spectra of the full range of galaxies, which may be used to predict the color-z relation). The ultimate goal of training is to minimize each moment of the distribution of differences between photometric redshift estimates and the true redshifts of objects, making the relationship between them as tight as possible. The larger and more complete our ''training set'' of spectroscopic redshifts is, the smaller the RMS photo-z errors should be, increasing the constraining power of imaging experiments; Requirements: Spectroscopic redshift measurements for ∼30,000 objects over >∼15 widely-separated regions, each at least ∼20 arcmin in diameter, and reaching the faintest objects used in a given experiment, will likely be necessary if photometric redshifts are to be trained and calibrated with conventional techniques. Larger, more complete samples (i.e., with longer exposure times) can improve photo

  7. Mossbauer spectroscopic studies in ferroboron

    Science.gov (United States)

    Yadav, Ravi Kumar; Govindaraj, R.; Amarendra, G.

    2017-05-01

    Mossbauer spectroscopic studies have been carried out in a detailed manner on ferroboron in order to understand the local structure and magnetic properties of the system. Evolution of the local structure and magnetic properties of the amorphous and crystalline phases and their thermal stability have been addressed in a detailed manner in this study. Role of bonding between Fe 4s and/or 4p electrons with valence electrons of boron (2s,2p) in influencing the stability and magnetic properties of Fe-B system is elucidated.

  8. Optimal Background Attenuation for Fielded Spectroscopic Detection Systems

    International Nuclear Information System (INIS)

    Robinson, Sean M.; Ashbaker, Eric D.; Schweppe, John E.; Siciliano, Edward R.

    2007-01-01

    Radiation detectors are often placed in positions difficult to shield from the effects of terrestrial background gamma radiation. This is particularly true in the case of Radiation Portal Monitor (RPM) systems, as their wide viewing angle and outdoor installations make them susceptible to radiation from the surrounding area. Reducing this source of background can improve gross-count detection capabilities in the current generation of non-spectroscopic RPM's as well as source identification capabilities in the next generation of spectroscopic RPM's. To provide guidance for designing such systems, the problem of shielding a general spectroscopic-capable RPM system from terrestrial gamma radiation is considered. This analysis is carried out by template matching algorithms, to determine and isolate a set of non-threat isotopes typically present in the commerce stream. Various model detector and shielding scenarios are calculated using the Monte-Carlo N Particle (MCNP) computer code. Amounts of nominal-density shielding needed to increase the probability of detection for an ensemble of illicit sources are given. Common shielding solutions such as steel plating are evaluated based on the probability of detection for 3 particular illicit sources of interest, and the benefits are weighed against the incremental cost of shielding. Previous work has provided optimal shielding scenarios for RPMs based on gross-counting measurements, and those same solutions (shielding the internal detector cavity, direct shielding of the ground between the detectors, and the addition of collimators) are examined with respect to their utility to improving spectroscopic detection

  9. Method of absorbance correction in a spectroscopic heating value sensor

    Science.gov (United States)

    Saveliev, Alexei; Jangale, Vilas Vyankatrao; Zelepouga, Sergeui; Pratapas, John

    2013-09-17

    A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

  10. THE SPECTROSCOPIC DIVERSITY OF TYPE Ia SUPERNOVAE

    International Nuclear Information System (INIS)

    Blondin, S.; Matheson, T.; Kirshner, R. P.; Mandel, K. S.; Challis, P.; Berlind, P.; Calkins, M.; Garnavich, P. M.; Jha, S. W.; Modjaz, M.; Riess, A. G.; Schmidt, B. P.

    2012-01-01

    We present 2603 spectra of 462 nearby Type Ia supernovae (SNe Ia), including 2065 previously unpublished spectra, obtained during 1993-2008 through the Center for Astrophysics Supernova Program. There are on average eight spectra for each of the 313 SNe Ia with at least two spectra. Most of the spectra were obtained with the FAST spectrograph at the Fred Lawrence Whipple Observatory 1.5 m telescope and reduced in a consistent manner, making this data set well suited for studies of SN Ia spectroscopic diversity. Using additional data from the literature, we study the spectroscopic and photometric properties of SNe Ia as a function of spectroscopic class using the classification schemes of Branch et al. and Wang et al. The width-luminosity relation appears to be steeper for SNe Ia with broader lines, although the result is not statistically significant with the present sample. Based on the evolution of the characteristic Si II λ6355 line, we propose improved methods for measuring velocity gradients, revealing a larger range than previously suspected, from ∼0 to ∼400 km s −1 day −1 considering the instantaneous velocity decline rate at maximum light. We find a weaker and less significant correlation between Si II velocity and intrinsic B – V color at maximum light than reported by Foley et al., owing to a more comprehensive treatment of uncertainties and host galaxy dust. We study the extent of nuclear burning and the presence of unburnt carbon in the outermost layers of the ejecta and report new detections of C II λ6580 in 23 early-time SN Ia spectra. The frequency of C II detections is not higher in SNe Ia with bluer colors or narrower light curves, in conflict with the recent results of Thomas et al. Based on nebular spectra of 27 SNe Ia, we find no relation between the FWHM of the iron emission feature at ∼4700 Å and Δm 15 (B) after removing the two low-luminosity SN 1986G and SN 1991bg, suggesting that the peak luminosity is not strongly dependent

  11. Polarized spectroscopic properties of Nd3+-doped KGd(WO4)2 single crystal

    International Nuclear Information System (INIS)

    Chen Yujin; Lin Yanfu; Gong Xinghong; Tan Qiguang; Zhuang Jian; Luo Zundu; Huang Yidong

    2007-01-01

    The polarized absorption spectra, infrared fluorescence spectra, upconversion visible fluorescence spectra, and fluorescence decay curve of orientated Nd 3+ :KGd(WO 4 ) 2 crystal were measured at room-temperature. Some important spectroscopic parameters were investigated in detail in the framework of the Judd-Ofelt theory and the Fuchtbauer-Ladenburg formula. The effect of the crystal structure on the spectroscopic properties of the Nd 3+ ions was analyzed. The relation among the spectroscopic parameters and the laser performances of the Nd 3+ :KGd(WO 4 ) 2 crystal was discussed

  12. Submillimeter Spectroscopic Study of Semiconductor Processing Plasmas

    Science.gov (United States)

    Helal, Yaser H.

    Plasmas used for manufacturing processes of semiconductor devices are complex and challenging to characterize. The development and improvement of plasma processes and models rely on feedback from experimental measurements. Current diagnostic methods are not capable of measuring absolute densities of plasma species with high resolution without altering the plasma, or without input from other measurements. At pressures below 100 mTorr, spectroscopic measurements of rotational transitions in the submillimeter/terahertz (SMM) spectral region are narrow enough in relation to the sparsity of spectral lines that absolute specificity of measurement is possible. The frequency resolution of SMM sources is such that spectral absorption features can be fully resolved. Processing plasmas are a similar pressure and temperature to the environment used to study astrophysical species in the SMM spectral region. Many of the molecular neutrals, radicals, and ions present in processing plasmas have been studied in the laboratory and their absorption spectra have been cataloged or are in the literature for the purpose of astrophysical study. Recent developments in SMM devices have made its technology commercially available for applications outside of specialized laboratories. The methods developed over several decades in the SMM spectral region for these laboratory studies are directly applicable for diagnostic measurements in the semiconductor manufacturing industry. In this work, a continuous wave, intensity calibrated SMM absorption spectrometer was developed as a remote sensor of gas and plasma species. A major advantage of intensity calibrated rotational absorption spectroscopy is its ability to determine absolute concentrations and temperatures of plasma species from first principles without altering the plasma environment. An important part of this work was the design of the optical components which couple 500 - 750 GHz radiation through a commercial inductively coupled plasma

  13. Preliminary Results from the Joint Russian and US Field Test: Measurement of Sensorimotor and Cardiovascular Responses Immediately Following Landing of the Soyuz Spacecraft

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Tomilovskaya, E. S.; Bloomberg, J. J.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; Stenger, M. B.; Lee, S. M. C.; Wood, S. J.; hide

    2013-01-01

    Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest have do serve as acceptable flight analogs, testing of crew responses following the long duration flights does not begin until a minimum of 24 hours after landing. As a result it is not possible to estimate the nonlinear trend of the early (testing at the time of landing and before the flight crews have left the landing site. By joint agreement this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long duration space flight crews beginning as soon after landing as possible (test in conjunction with postural ataxia testing. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired at a minimum of one to three more other times within the 24 hr following landing and continue until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of jointly agreed tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content, and implementation. The PFT is currently scheduled for the September 2013 landing of the Soyuz spacecraft (34S). Testing will include: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember begins in the prone

  14. Preliminary 3D In-situ measurements of the texture evolution of strained H2O ice during annealing using neutron Laue diffractometry

    Science.gov (United States)

    Journaux, Baptiste; Montagnat, Maurine; Chauve, Thomas; Ouladdiaf, Bachir; Allibon, John

    2015-04-01

    Dynamic recrystallization (DRX) strongly affects the evolution of microstructure (grain size and shape) and texture (crystal preferred orientation) in materials during deformation at high temperature. Since texturing leads to anisotropic physical properties, predicting the effect of DRX is essential for industrial applications, for interpreting geophysical data and modeling geodynamic flows, and predicting ice sheet flow and climate evolution. A large amount of literature is available related to metallurgy, geology or glaciology, but there remains overall fundamental questions about the relationship between nucleation, grain boundary migration and texture development at the microscopic scale. Previous measurements of DRX in ice were either conducted using 2D ex-situ techniques such as AITA [1,2] or Electron Backscattering Diffraction (EBSD) [3], or using 3D statistical ex-situ [4] or in-situ [5] techniques. Nevertheless, all these techniques failed to observe at the scale of nucleation processes during DRX in full 3D. Here we present a new approach using neutron Laue diffraction, which enable to perform 3D measurements of in-situ texture evolution of strained polycrystalline H2O ice (>2% at 266 K) during annealing at the microscopic scale. Thanks the CYCLOPS instrument [6] (Institut Laue Langevin Grenoble, France) and the intrinsic low background of this setup, preliminary observations enabled us to follow, in H2O ice, the evolution of serrated grain boundaries, and kink-band during annealing. Our observations show a significant evolution of the texture and internal misorientation over the course of few hours at an annealing temperature of 268.5 K. In the contrary, ice kink-band structures seem to be very stable over time at near melting temperatures. The same samples have been analyzed ex-situ using EBSD for comparison. These results represent a first step toward in-situ microscopic measurements of dynamic recrystallization processes in ice during strain. This

  15. THE BARYON OSCILLATION SPECTROSCOPIC SURVEY OF SDSS-III

    International Nuclear Information System (INIS)

    Dawson, Kyle S.; Ahn, Christopher P.; Bolton, Adam S.; Schlegel, David J.; Bailey, Stephen; Anderson, Scott F.; Bhardwaj, Vaishali; Aubourg, Éric; Bautista, Julian E.; Barkhouser, Robert H.; Beifiori, Alessandra; Berlind, Andreas A.; Bizyaev, Dmitry; Brewington, Howard; Blake, Cullen H.; Blanton, Michael R.; Blomqvist, Michael; Borde, Arnaud; Bovy, Jo; Brandt, W. N.

    2013-01-01

    The Baryon Oscillation Spectroscopic Survey (BOSS) is designed to measure the scale of baryon acoustic oscillations (BAO) in the clustering of matter over a larger volume than the combined efforts of all previous spectroscopic surveys of large-scale structure. BOSS uses 1.5 million luminous galaxies as faint as i = 19.9 over 10,000 deg 2 to measure BAO to redshifts z A to an accuracy of 1.0% at redshifts z = 0.3 and z = 0.57 and measurements of H(z) to 1.8% and 1.7% at the same redshifts. Forecasts for Lyα forest constraints predict a measurement of an overall dilation factor that scales the highly degenerate D A (z) and H –1 (z) parameters to an accuracy of 1.9% at z ∼ 2.5 when the survey is complete. Here, we provide an overview of the selection of spectroscopic targets, planning of observations, and analysis of data and data quality of BOSS.

  16. Spectroscopic Doppler analysis for visible-light optical coherence tomography

    Science.gov (United States)

    Shu, Xiao; Liu, Wenzhong; Duan, Lian; Zhang, Hao F.

    2017-12-01

    Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.

  17. Ex-vivo holographic microscopy and spectroscopic analysis of head and neck cancer

    Science.gov (United States)

    Holler, Stephen; Wurtz, Robert; Auyeung, Kelsey; Auyeung, Kris; Paspaley-Grbavac, Milan; Mulroe, Brigid; Sobrero, Maximiliano; Miles, Brett

    2015-03-01

    Optical probes to identify tumor margins in vivo would greatly reduce the time, effort and complexity in the surgical removal of malignant tissue in head and neck cancers. Current approaches involve visual microscopy of stained tissue samples to determine cancer margins, which results in the excision of excess of tissue to assure complete removal of the cancer. Such surgical procedures and follow-on chemotherapy can adversely affect the patient's recovery and subsequent quality of life. In order to reduce the complexity of the process and minimize adverse effects on the patient, we investigate ex vivo tissue samples (stained and unstained) using digital holographic microscopy in conjunction with spectroscopic analyses (reflectance and transmission spectroscopy) in order to determine label-free, optically identifiable characteristic features that may ultimately be used for in vivo processing of cancerous tissues. The tissue samples studied were squamous cell carcinomas and associated controls from patients of varying age, gender and race. Holographic microscopic imaging scans across both cancerous and non-cancerous tissue samples yielded amplitude and phase reconstructions that were correlated with spectral signatures. Though the holographic reconstructions and measured spectra indicate variations even among the same class of tissue, preliminary results indicate the existence of some discriminating features. Further analyses are presently underway to further this work and extract additional information from the imaging and spectral data that may prove useful for in vivo surgical identification.

  18. Preliminary Finnish Measures of Eating Competence Suggest Association with Health-Promoting Eating Patterns and Related Psychobehavioral Factors in 10?17 Year Old Adolescents

    OpenAIRE

    Tanja, Tilles-Tirkkonen; Outi, Nuutinen; Sakari, Suominen; Jarmo, Liukkonen; Kaisa, Poutanen; Leila, Karhunen

    2015-01-01

    Eating competence is an attitudinal and behavioral concept, based on The Satter Eating Competence Model. In adults, it has been shown to be associated with a higher quality of diet. Eating competence or its association with the quality of diet has not been studied in adolescents. The aim of the current study was to explore the utility of using a preliminary Finnish translation of the ecSI 2.0 for evaluating presumed eating competence and its association with food selection, mea...

  19. Raman spectroscopic studies of hydrogen clathrate hydrates.

    Science.gov (United States)

    Strobel, Timothy A; Sloan, E Dendy; Koh, Carolyn A

    2009-01-07

    Raman spectroscopic measurements of simple hydrogen and tetrahydrofuran+hydrogen sII clathrate hydrates have been performed. Both the roton and vibron bands illuminate interesting quantum dynamics of enclathrated H(2) molecules. The complex vibron region of the Raman spectrum has been interpreted by observing the change in population of these bands with temperature, measuring the absolute H(2) content as a function of pressure, and with D(2) isotopic substitution. Quadruple occupancy of the large sII clathrate cavity shows the highest H(2) vibrational frequency, followed by triple and double occupancies. Singly occupied small cavities display the lowest vibrational frequency. The vibrational frequencies of H(2) within all cavity environments are redshifted from the free gas phase value. At 76 K, the progression from ortho- to para-H(2) occurs over a relatively slow time period (days). The rotational degeneracy of H(2) molecules within the clathrate cavities is lifted, observed directly in splitting of the para-H(2) roton band. Raman spectra from H(2) and D(2) hydrates suggest that the occupancy patterns between the two hydrates are analogous, increasing confidence that D(2) is a suitable substitute for H(2). The measurements suggest that Raman is an effective and convenient method to determine the relative occupancy of hydrogen molecules in different clathrate cavities.

  20. Preliminary Finnish Measures of Eating Competence Suggest Association with Health-Promoting Eating Patterns and Related Psychobehavioral Factors in 10–17 Year Old Adolescents

    Directory of Open Access Journals (Sweden)

    Tilles-Tirkkonen Tanja

    2015-05-01

    Full Text Available Eating competence is an attitudinal and behavioral concept, based on The Satter Eating Competence Model. In adults, it has been shown to be associated with a higher quality of diet. Eating competence or its association with the quality of diet has not been studied in adolescents. The aim of the current study was to explore the utility of using a preliminary Finnish translation of the ecSI 2.0 for evaluating presumed eating competence and its association with food selection, meal patterns and related psychobehavioral factors in 10–17 year old adolescents. Altogether 976 10–17 years old Finnish adolescents filled in the study questionnaire. When exploring the construct validity of ecSI 2.0, the confirmatory factor analysis (CFA indicated acceptable model fit and all four components of the ecSI 2.0 (eating attitudes, food acceptance, internal regulation of food intake, management of eating context correlated with each other and were internally consistent. Over half (58% of the adolescents scored 32 or higher and were thus classified as presumably eating competent (pEC. Eating competence was associated with greater meal frequency, more frequent consumption of vegetables and fruits, and more health-promoting family eating patterns. In addition the pEC, adolescents more often perceived their body size as appropriate, had less often tried to lose weight and had a higher self-esteem and a stronger sense of coherence than the not pEC ones. Family eating patterns and self-esteem were the main underlying factors of eating competence. In conclusion, this preliminary study suggests eating competence could be a useful concept to characterize eating patterns and related behaviors and attitudes in adolescents. However, these preliminary findings need to be confirmed in further studies with an instrument fully validated for this age group.

  1. Preliminary Finnish measures of eating competence suggest association with health-promoting eating patterns and related psychobehavioral factors in 10-17 year old adolescents.

    Science.gov (United States)

    Tanja, Tilles-Tirkkonen; Outi, Nuutinen; Sakari, Suominen; Jarmo, Liukkonen; Kaisa, Poutanen; Leila, Karhunen

    2015-05-21

    Eating competence is an attitudinal and behavioral concept, based on The Satter Eating Competence Model. In adults, it has been shown to be associated with a higher quality of diet. Eating competence or its association with the quality of diet has not been studied in adolescents. The aim of the current study was to explore the utility of using a preliminary Finnish translation of the ecSI 2.0 for evaluating presumed eating competence and its association with food selection, meal patterns and related psychobehavioral factors in 10-17 year old adolescents. Altogether 976 10-17 years old Finnish adolescents filled in the study questionnaire. When exploring the construct validity of ecSI 2.0, the confirmatory factor analysis (CFA) indicated acceptable model fit and all four components of the ecSI 2.0 (eating attitudes, food acceptance, internal regulation of food intake, management of eating context) correlated with each other and were internally consistent. Over half (58%) of the adolescents scored 32 or higher and were thus classified as presumably eating competent (pEC). Eating competence was associated with greater meal frequency, more frequent consumption of vegetables and fruits, and more health-promoting family eating patterns. In addition the pEC, adolescents more often perceived their body size as appropriate, had less often tried to lose weight and had a higher self-esteem and a stronger sense of coherence than the not pEC ones. Family eating patterns and self-esteem were the main underlying factors of eating competence. In conclusion, this preliminary study suggests eating competence could be a useful concept to characterize eating patterns and related behaviors and attitudes in adolescents. However, these preliminary findings need to be confirmed in further studies with an instrument fully validated for this age group.

  2. Preliminary Finnish Measures of Eating Competence Suggest Association with Health-Promoting Eating Patterns and Related Psychobehavioral Factors in 10–17 Year Old Adolescents

    Science.gov (United States)

    Tanja, Tilles-Tirkkonen; Outi, Nuutinen; Sakari, Suominen; Jarmo, Liukkonen; Kaisa, Poutanen; Leila, Karhunen

    2015-01-01

    Eating competence is an attitudinal and behavioral concept, based on The Satter Eating Competence Model. In adults, it has been shown to be associated with a higher quality of diet. Eating competence or its association with the quality of diet has not been studied in adolescents. The aim of the current study was to explore the utility of using a preliminary Finnish translation of the ecSI 2.0 for evaluating presumed eating competence and its association with food selection, meal patterns and related psychobehavioral factors in 10–17 year old adolescents. Altogether 976 10–17 years old Finnish adolescents filled in the study questionnaire. When exploring the construct validity of ecSI 2.0, the confirmatory factor analysis (CFA) indicated acceptable model fit and all four components of the ecSI 2.0 (eating attitudes, food acceptance, internal regulation of food intake, management of eating context) correlated with each other and were internally consistent. Over half (58%) of the adolescents scored 32 or higher and were thus classified as presumably eating competent (pEC). Eating competence was associated with greater meal frequency, more frequent consumption of vegetables and fruits, and more health-promoting family eating patterns. In addition the pEC, adolescents more often perceived their body size as appropriate, had less often tried to lose weight and had a higher self-esteem and a stronger sense of coherence than the not pEC ones. Family eating patterns and self-esteem were the main underlying factors of eating competence. In conclusion, this preliminary study suggests eating competence could be a useful concept to characterize eating patterns and related behaviors and attitudes in adolescents. However, these preliminary findings need to be confirmed in further studies with an instrument fully validated for this age group. PMID:26007335

  3. Preliminary HECTOR analysis by Dragon

    Energy Technology Data Exchange (ETDEWEB)

    Presser, W; Woloch, F

    1972-06-02

    From the different cores measured in HECTOR, only ACH 4/B-B was selected for the Dragon analysis, since it presented the largest amount of uniform fuel loading in the central test region and is therefore nearest to an infinite lattice. Preliminary results are discussed.

  4. Cross-cultural adaptation and preliminary psychometric properties of the Affective Reactivity Index in Brazilian Youth: implications for DSM-5 measured irritability

    Directory of Open Access Journals (Sweden)

    Diogo Araújo DeSousa

    2013-01-01

    Full Text Available Objective: To describe the cross-cultural adaptation of the Affective Reactivity Index (ARI to Brazilian Portuguese and to investigate preliminary psychometric properties of the adapted version. Methods: Cross-cultural adaptation was based on the investigation of the theoretical and operational equivalences of the original ARI in the Brazilian context, followed by a process of translation, back-translation, and review by a committee of experts. Data analysis was carried out in a community sample of 133 schoolchildren aged 8 to 17 years to investigate the following characteristics of the ARI: 1 factor structure; 2 internal consistency; 3 construct validity comparing differential relationships between irritability and anxiety dimensions and impairment; and 4 item response theory (IRT parameters. Results: A final Brazilian Portuguese version of the instrument was defined and is presented. Internal consistency was good, and our analysis supported the original single-factor structure of the ARI. Correlations of the ARI with distress-related anxiety dimensions were higher than with phobic-related anxiety dimensions, supporting its construct validity. In addition, higher ARI scores were associated with higher irritability-related impairment. IRT analysis underscored frequency of loss of temper as essential to inform about pathological states of irritability. Conclusion: The Brazilian Portuguese version of the ARI seems to be very similar to the original instrument in terms of conceptual, item, semantic, and operational equivalence. Our preliminary analysis replicates and extends previous evidence confirming promising psychometric properties for the ARI.

  5. Spectroscopic studies of copper enzymes

    International Nuclear Information System (INIS)

    Dooley, D.M.; Moog, R.; Zumft, W.; Koenig, S.H.; Scott, R.A.; Cote, C.E.; McGuirl, M.

    1986-01-01

    Several spectroscopic methods, including absorption, circular dichroism (CD), magnetic CD (MCD), X-ray absorption, resonance Raman, EPR, NMR, and quasi-elastic light-scattering spectroscopy, have been used to probe the structures of copper-containing amine oxidases, nitrite reductase, and nitrous oxide reductase. The basic goals are to determine the copper site structure, electronic properties, and to generate structure-reactivity correlations. Collectively, the results on the amine oxidases permit a detailed model for the Cu(II) sites in these enzymes to be constructed that, in turn, rationalizes the ligand-binding chemistry. Resonance Raman spectra of the phenylhydrazine and 2,4-dinitrophenyl-hydrazine derivatives of bovine plasma amine oxidase and models for its organic cofactor, e.g. pyridoxal, methoxatin, are most consistent with methoxatin being the intrinsic cofactor. The structure of the Cu(I) forms of the amine oxidases have been investigated by X-ray absorption spectroscopy (XAS); the copper coordination geometry is significantly different in the oxidized and reduced forms. Some anomalous properties of the amine oxidases in solution are explicable in terms of their reversible aggregation, which the authors have characterized via light scattering. Nitrite and nitrous oxide reductases display several novel spectral properties. The data suggest that new types of copper sites are present

  6. Preliminary Monthly Climatological Summaries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Preliminary Local Climatological Data, recorded since 1970 on Weather Burean Form 1030 and then National Weather Service Form F-6. The preliminary climate data pages...

  7. EPR spectroscopic investigation of psoriatic finger nails.

    Science.gov (United States)

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Spectroscopic characterization of alkaline earth uranyl carbonates

    International Nuclear Information System (INIS)

    Amayri, Samer; Reich, Tobias; Arnold, Thuro; Geipel, Gerhard; Bernhard, Gert

    2005-01-01

    A series of alkaline uranyl carbonates, M[UO 2 (CO 3 ) 3 ].nH 2 O (M=Mg 2 , Ca 2 , Sr 2 , Ba 2 , Na 2 Ca, and CaMg) was synthesized and characterized by inductively coupled plasma mass spectrometry (ICP-MS) and atomic absorption spectrometry (AAS) after nitric acid digestion, X-ray powder diffraction (XRD), and thermal analysis (TGA/DTA). The molecular structure of these compounds was characterized by extended X-ray absorption fine-structure (EXAFS) spectroscopy and X-ray photoelectron spectroscopy (XPS). Crystalline Ba 2 [UO 2 (CO 3 ) 3 ].6H 2 O was obtained for the first time. The EXAFS analysis showed that this compound consists of (UO 2 )(CO 3 ) 3 clusters similar to the other alkaline earth uranyl carbonates. The average U-Ba distance is 3.90+/-0.02A.Fluorescence wavelengths and life times were measured using time-resolved laser-induced fluorescence spectroscopy (TRLFS). The U-O bond distances determined by EXAFS, TRLFS, XPS, and Raman spectroscopy agree within the experimental uncertainties. The spectroscopic signatures observed could be useful for identifying uranyl carbonate species adsorbed on mineral surfaces

  9. Vacuum arc anode plasma. I. Spectroscopic investigation

    International Nuclear Information System (INIS)

    Bacon, F.M.

    1975-01-01

    A spectroscopic investigation was made of the anode plasma of a pulsed vacuum arc with an aluminum anode and a molybdenum cathode. The arc was triggered by a third trigger electrode and was driven by a 150-A 10-μs current pulse. The average current density at the anode was sufficiently high that anode spots were formed; these spots are believed to be the source of the aluminum in the plasma investigated in this experiment. By simultaneously measuring spectral emission lines of Al I, Al II, and Al III, the plasma electron temperature was shown to decrease sequentially through the norm temperatures of Al III, Al II, and Al I as the arc was extinguished. The Boltzmann distribution temperature T/subD/ of four Al III excited levels was shown to be kT/subD//e=2.0plus-or-minus0.5 V, and the peak Al III 4D excited state density was shown to be about 5times10 17 m -3 . These data suggest a non-local-thermodynamic-equilibrium (non-LTE) model of the anode plasma when compared with the Al 3+ production in the plasma. The plasma was theoretically shown to be optically thin to the observed Al III spectral lines

  10. Theoretical predictions for alpha particle spectroscopic strengths

    International Nuclear Information System (INIS)

    Draayer, J.P.

    1975-01-01

    Multinucleon transfers induced in heavy-ion reactions of the type ( 6 Li,d) furnish a selective probe with which to study the interplay between rotational and clustering phenomena so characteristic of the structure of the light sd-shell nuclei. For these nuclei, theoretical predictions for inter-band as well as intra-band transfer strengths can be made using recently tabulated results for angular momentum dependent SU 3 inclusion R 3 relative spectroscopic strengths and angular momentum independent SU 6 inclusion SU 3 coefficients of fractional parentage. The pure SU 3 (oscillator)-SU 4 (supermultiplet) symmetry limit agrees well with results obtained using available eigenfunctions determined in large shell model calculations. In particular, the scalar nature of a transferred ''alpha''-cluster insures that the effect of spatial symmetry admixtures in the initial and final states of the target and residual nuclei are minimized. Sum rule quantities provide a measure of the probable effects of symmetry breaking. Strength variations within a band are expected; transfers to core excited states are often favored. Results extracted from exact finite range DWBA analyses of ( 6 Li,d) data on 16 , 18 O, 20 , 21 , 22 Ne, 24 , 25 Mg show some anomalies in our understanding of the structure and/or reaction mechanisms. (18 figures) (U.S.)

  11. Spectroscopic Observations of Nearby Low Mass Stars

    Science.gov (United States)

    Vican, Laura; Zuckerman, B. M.; Rodriguez, D.

    2014-01-01

    Young low-mass stars are known to be bright in X-ray and UV due to a high level of magnetic activity. By cross-correlating the GALEX Catalog with the WISE and 2MASS Point Source Catalogs, we have identified more than 2,000 stars whose UV excesses suggest ages in the 10-100 Myr range. We used the Shane 3-m telescope at Lick Observatory on Mount Hamilton, California to observe some of these 2,000 stars spectroscopically. We measured the equivalent width of lithium at 6708 A absorption and H-alpha emission lines. Out of a total of 122 stars observed with the Kast grating spectrometer, we find that roughly 10% have strong lithium absorption features. The high percentage of stars with lithium present is further evidence of the importance of UV emission as a youth indicator for low-mass stars. In addition, we used high-resolution spectra obtained with the Hamilton echelle spectrograph to determine radial velocities for several UV-bright stars. These radial velocities will be useful for the calculat