WorldWideScience

Sample records for preliminary screening tests

  1. Phytochemical Screening and Preliminary Evaluation of Analgesic ...

    African Journals Online (AJOL)

    In this study, the methanolic root extract of Cissus polyantha was subjected to preliminary phytochemical screening, analgesic and anti-inflammatory studies. Phytochemical studies was carried out using standard phytochemical protocol while the analgesic studies was carried out using acetic acid-induced writhing tests in ...

  2. Preliminary screening of plant essential oils against larvae of Culex ...

    African Journals Online (AJOL)

    Preliminary screenings of 22 plant essential oils were tested for mortality of the mosquito larvae Culex quinquefasciatus under laboratory conditions. Percent (%) mortality of the mosquito larvae were obtained for each essential oil. At different exposure periods, viz. 1, 3, 6, 12 and 24 h among the 22 plant oils tested, eight ...

  3. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    Science.gov (United States)

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  4. Jaw-opening force test to screen for Dysphagia: preliminary results.

    Science.gov (United States)

    Hara, Koji; Tohara, Haruka; Wada, Satoko; Iida, Takatoshi; Ueda, Koichiro; Ansai, Toshihiro

    2014-05-01

    To assess the jaw-opening force test (JOFT) for dysphagia screening. Criterion standard. University dental hospital. Patients complaining of dysphagia (N=95) and with symptoms of dysphagia with chronic underlying causes (mean age ± SD, 79.3±9.61y; range, 50-94y; men: n=49; mean age ± SD, 77.03±9.81y; range, 50-94y; women: n=46; mean age ± SD, 75.42±9.73y; range, 51-93y) admitted for treatment between May 2011 and December 2012 were included. None. All patients were administered the JOFT and underwent fiberoptic endoscopic evaluation of swallowing (FEES). The mean jaw-opening strength was compared with aspiration (ASP) and pharyngeal residue observations of the FEES, which was used as the criterion standard. A receiver operating characteristic (ROC) curve analysis was performed. Forces of ≤3.2kg for men and ≤4kg for women were appropriate cutoff values for predicting ASP with a sensitivity and specificity of .57 and .79 for men and .93 and .52 for women, respectively. Based on the ROC analyses for predicting pharyngeal residue, forces of ≤5.3kg in men and ≤3.9kg in women were appropriate cutoff values, with a sensitivity and specificity of .80 and .88 for men and .83 and .81 for women, respectively. The JOFT could be a useful screening tool for predicting pharyngeal residue and could provide useful information to aid in the referral of patients for further diagnostic imaging testing. However, given its low sensitivity to ASP the JOFT should be paired with other screening tests that predict ASP. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Development and preliminary validation of a screen for ...

    African Journals Online (AJOL)

    Development and preliminary validation of a screen for interpersonal childhood trauma experiences among school-going youth in Durban, South Africa. ... validity in the sense that all scales were significantly correlated with scores on clinical measures of post-traumatic stress disorder (PTSD) and/or complex PTSD.

  6. Interpretation of Errors Made by Mandarin-Speaking Children on the Preschool Language Scales--5th Edition Screening Test

    Science.gov (United States)

    Ren, Yonggang; Rattanasone, Nan Xu; Wyver, Shirley; Hinton, Amber; Demuth, Katherine

    2016-01-01

    We investigated typical errors made by Mandarin-speaking children when measured by the Preschool Language Scales-fifth edition, Screening Test (PLS-5 Screening Test). The intention was to provide preliminary data for the development of a guideline for early childhood educators and psychologists who use the test with Mandarin-speaking children.…

  7. A closer look at the effect of preliminary goodness-of-fit testing for normality for the one-sample t-test.

    Science.gov (United States)

    Rochon, Justine; Kieser, Meinhard

    2011-11-01

    Student's one-sample t-test is a commonly used method when inference about the population mean is made. As advocated in textbooks and articles, the assumption of normality is often checked by a preliminary goodness-of-fit (GOF) test. In a paper recently published by Schucany and Ng it was shown that, for the uniform distribution, screening of samples by a pretest for normality leads to a more conservative conditional Type I error rate than application of the one-sample t-test without preliminary GOF test. In contrast, for the exponential distribution, the conditional level is even more elevated than the Type I error rate of the t-test without pretest. We examine the reasons behind these characteristics. In a simulation study, samples drawn from the exponential, lognormal, uniform, Student's t-distribution with 2 degrees of freedom (t(2) ) and the standard normal distribution that had passed normality screening, as well as the ingredients of the test statistics calculated from these samples, are investigated. For non-normal distributions, we found that preliminary testing for normality may change the distribution of means and standard deviations of the selected samples as well as the correlation between them (if the underlying distribution is non-symmetric), thus leading to altered distributions of the resulting test statistics. It is shown that for skewed distributions the excess in Type I error rate may be even more pronounced when testing one-sided hypotheses. ©2010 The British Psychological Society.

  8. Weldon Spring, Missouri, Raffinate Pits 1, 2, 3, and 4: Preliminary grout development screening studies for in situ waste immobilization

    International Nuclear Information System (INIS)

    McDaniel, E.W.; Gilliam, T.M.; Dole, L.R.; West, G.A.

    1987-04-01

    Results of Oak Ridge National Laboratory's initial support program to develop a preliminary grout formula to solidify in situ the Weldon Spring waste are presented. The screening study developed preliminary formulas based on a simulated composite waste and then tested the formulas on actual waste samples. Future data needs are also discussed. 1 ref., 6 figs., 9 tabs

  9. Preliminary Phytochemical Screening of Fresh and Dried Moringa ...

    African Journals Online (AJOL)

    The preliminary phytochemical screening of the crude aqueous extract of fresh and dried Moringa oleifera leaves, of the organic solvent and residual fractions of the extract was carried out according to the standard methods. Chemical constituents of the crude aqueous extract of the fresh leaves were found to be tannins, ...

  10. A virtual test of screening technology based on the AGEIA PhysX

    Energy Technology Data Exchange (ETDEWEB)

    Ai-min Li; Rui-ling Lv; Chu-sheng Liu [China University of Mining and Technology, Xuzhou (China). School of Mechanical and Electrical Engineering

    2008-06-15

    The authors have created a virtual test of vibration particle-screening using Autodesk's 3ds Max software, the MAXScript scripting language and the AGEIA PhysX physics processing unit (PPU). The affect of various parameters on screening efficiency were modeled. The parameters included vibration amplitude, frequency and direction. The length and inclination of the vibrating surface were also varied. The virtual experiment is in basic agreement with results predicted from screening theory. This shows that the virtual screener can be used for preliminary investigations and the results used to evaluate screen design. In addition it can help with theoretical research. 11 refs., 7 figs., 7 tabs.

  11. Preliminary biological screening of microbes isolated from cow dung ...

    African Journals Online (AJOL)

    Preliminary biological screening of microbes isolated from cow dung in Kampar. KC Teo, SM Teoh. Abstract. Five distinct morphologically and physiologically isolates were isolated from cow dung at Kampar, Perak, Malaysia and cultured on nutrient agar (NA) plates. Morphological studies including microscopic examination ...

  12. On Preliminary Test Estimator for Median

    OpenAIRE

    Okazaki, Takeo; 岡崎, 威生

    1990-01-01

    The purpose of the present paper is to discuss about estimation of median with a preliminary test. Two procedures are presented, one uses Median test and the other uses Wilcoxon two-sample test for the preliminary test. Sections 3 and 4 give mathematical formulations of such properties, including mean square errors with one specified case. Section 5 discusses their optimal significance levels of the preliminary test and proposes their numerical values by Monte Carlo method. In addition to mea...

  13. 1ST-TRIMESTER SCREENING FOR FETAL CHROMOSOMAL-ABNORMALITIES - PRELIMINARY-RESULTS

    NARCIS (Netherlands)

    VANLITH, JMM

    We have started a multicentre trial to study the possibilities of first-trimester maternal serum screening for fetal chromosomal abnormalities. Maternal blood samples were obtained before 13 weeks of gestation. We present the preliminary results of the first 950 patients on alpha-fetoprotein (AFP).

  14. Preliminary ten year results from a randomised single centre mass screening trial for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Fasting, H

    2006-01-01

    At present, several regions and countries are considering screening for abdominal aortic aneurysm (AAA). However, The Chichester Aneurysms Screening Trial has reported poor long term benefit of screening for AAA. We therefore supplement previously published data with a preliminary analysis...

  15. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  16. Smartphone-based fluorescence spectroscopy device aiding in preliminary skin screening

    Science.gov (United States)

    Sahoo, Aparajita; Wahi, Akshat; Das, Anshuman

    2018-02-01

    Preliminary diagnosis of closely resembling skin conditions can be highly subjective for dermatologists. In ambiguous cases, it often leads to performing invasive procedures like biopsies. Different skin conditions, however, have varying concentrations of fluorophores (like collagen, NADH) and chromophores (like melanin, hemoglobin) which can alter their fluorescence spectra. We demonstrate a handheld, portable, smartphone-based spectrometer that leverages these alterations in skin autofluorescence spectra for rapid screening of skin conditions. This methodology involves excitation of affected skin areas with ultraviolet (UV-A) 385 nm light, capturing the generated fluorescence spectra and sending the data wirelessly to a companion mobile application for data storage, analysis and visualization. By collecting the fluorescence spectral signals from healthy and unhealthy skin conditions, we establish that the signals collected using this portable device can be used to develop a classification method to help in differentially diagnosing these conditions. It shows promise as a useful skin screening tool for both dermatologists and primary health care workers. This device can enable quick, non-invasive and a more objective preliminary examination. We envision the device to be especially useful in primary healthcare centers of developing countries where availability of dermatologists is limited.

  17. Preliminary results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Matsumoto, T.; Komine, K.; Arai, S.

    1997-01-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented

  18. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  19. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  20. A Chinese version of the Language Screening Test (CLAST for early-stage stroke patients.

    Directory of Open Access Journals (Sweden)

    Hongyan Yang

    Full Text Available There is a severe lack of aphasia screening tools for bedside use in Chinese. A number of aphasia assessment tools have recently been developed abroad, but some of these scales were not suitable for patients with acute stroke. The Language Screening Test (which includes two parallel versions [a/b] in French has been proven to be an effective and time-saving aphasia screening scale for early-stage stroke patients. Therefore, we worked out a Chinese version of the LAST taking into consideration Chinese language and culture. Two preliminary parallel versions (a/b were tested on 154 patients with stroke at acute phase and 107 patients with stroke at non-acute phase, with the Western Aphasia Battery serving as a gold standard. The equivalence between the two parallel versions and the reliability/validity of each version were assessed. The median time to complete one preliminary Chinese version (each had some item redundancy was 98 seconds. Two final parallel versions were established after adjustment/elimination of the redundant items and were found to be equivalent (intra-class correlation coefficient: 0.991. Internal consistency is(Cronbach α for each version [a/b] was 0.956 and 0.965, respectively good. Internal validity was fine: (a no floor or ceiling effect/item redundancy; (b construct validity revealed a 1-dimension structure, just like the French version. The higher educated subjects scored higher than their lower educated counterparts (p<0.01. The external validity: at the optimum cut-off point where the score of version a/b <14 in higher educated group(<13 in lower: the specificity of each version was 0.878/0.902(1/1 in lower and sensitivity was 0.972/0.944(0.944/0.944 in lower. Inter-rater equivalence (intra-class correlation coefficient was 1. The Chinese version of the Language Screening Test was proved to be an efficient and time-saving bedside aphasia screening tool for stroke patients at acute phase and can be used by an average

  1. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  2. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  3. Neonatal cystic fibrosis screening test

    Science.gov (United States)

    Cystic fibrosis screening - neonatal; Immunoreactive trypsinogen; IRT test; CF - screening ... Cystic fibrosis is a disease passed down through families. CF causes thick, sticky mucus to build up in ...

  4. Proximate composition, phytochemical screening and antianaemic ...

    African Journals Online (AJOL)

    In this study, the phytochemical screening and anti-anaemic effect of Aloe barbadensis leaves was investigated in nutritionally stressed rats. Preliminary phytochemical screening test of the plant revealed that it contained tannins, flavonoids, anthraquinones, saponins, alkaloids and cardiac glycosides. Sets of male albino ...

  5. Review of Autism Screening Tests

    Directory of Open Access Journals (Sweden)

    Farin Soleimani

    2014-10-01

    Full Text Available Background: Autism is a neurodevelopmental disorder that onset in the first 3 years of life and led to lifelong disability.Despite the early onset of symptoms, diagnosis of thissyndromedoes not happenuntil severalyears later, somany childrenlosethe opportunityfor earlyintervention.There arevarious toolsforscreening anddiagnosis, buttheirdesign, strengths and weaknesses aredifferent. The aim of this study was assess these tools from various aspects to provide a comprehensive view. Materials and methods: This study is a narrative literature review on screeningtoolsof autism. Comprehensive searches of the scientific literature were conducted in textbooks and 8 electronic databases(proquest,wiley,google scholar,SID,Scopus, Web of Science ،Science Direct ، and Medline and Pediatric book. language restriction (Persian and English was applied. The search strategy consisted of keywords and medical subject headings for autism and various screening tests. Result: In this study, 28 screening tests were identified from 1992 to 2014. CHAT is oldest test and the most recent test is CAST The minimum age that can perform the screening is six months that related to ITC. Minimum time of testing was 5 minutes  for CHAT and the maximum time was 90-120 minutes for ASIEP-3.RAADS-R test was the highest specificity and specificity (100% and the lowest specificity was 14% in ESAT test Conclusion: The results of this study indicate that any of the autism screening tools consider specific skill and various aspects of the disease, careful evaluation is need to choose proper test.

  6. Universal newborn hearing screening: preliminary experience at the University Hospital of Cagliari

    Directory of Open Access Journals (Sweden)

    Giulia Pinna

    2012-10-01

    Full Text Available Bilateral congenital or acquired sensorineural hearing loss is a pathological condition affecting 1-2 children per 1,000 live births; it represents a major issue in public health because its late identification can negatively affect speech and language development. The aim of hearing screening is to obtain diagnosis and management of hearing loss as soon as possible; in fact early diagnosis and treatment allow children with congenital hearing impairment to acquire adequate linguistic competence. The present study reports our preliminary experience in newborn hearing screening at Neonatology services of University of Cagliari (Italy. During the first semester of surveillance, between January 2012 and June 2012, hearing screening was performed on a total of 901 babies using two different methods, TEOAEs in healthy neonates and automated ABR in high-risk babies. All infants were screened prior to hospital discharge; in some cases, especially for preterm infants of Neonatal Intensive Care Unit and Puericulture Institute, the screening was performed after discharge, to achieve a possible better global and acoustic maturation; 5 cases of hearing impairment were found. In the present study the Authors confirmed that it is possible to start a universal hearing screening in a relatively short time reaching the percentages suggested by Joint Committee on Infant Hearing.

  7. Older adults’ preferences for colorectal cancer-screening test attributes and test choice

    Directory of Open Access Journals (Sweden)

    Kistler CE

    2015-07-01

    Full Text Available Christine E Kistler,1–3 Thomas M Hess,4 Kirsten Howard,5,6 Michael P Pignone,2,3,7 Trisha M Crutchfield,2,3,8 Sarah T Hawley,9 Alison T Brenner,2 Kimberly T Ward,2 Carmen L Lewis10 1Department of Family Medicine, School of Medicine, 2Cecil G Sheps Center for Health Services Research, 3Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, 4Department of Psychology, North Carolina State University, Raleigh, NC, USA; 5Institute for Choice, University of South Australia, Sydney, NSW, Australia; 6School of Public Health, University of Sydney, Sydney, NSW, Australia; 7Division of General Internal Medicine, School of Medicine, 8Center for Health Promotion and Disease Prevention, University of North Carolina at Chapel Hill, Chapel Hill, NC, 9Department of Medicine, University of Michigan, Ann Arbor, MI, 10Division of General Internal Medicine, Department of Medicine, University of Colorado School of Medicine, Aurora, CO, USA Background: Understanding which attributes of colorectal cancer (CRC screening tests drive older adults’ test preferences and choices may help improve decision making surrounding CRC screening in older adults.Materials and methods: To explore older adults’ preferences for CRC-screening test attributes and screening tests, we conducted a survey with a discrete choice experiment (DCE, a directly selected preferred attribute question, and an unlabeled screening test-choice question in 116 cognitively intact adults aged 70–90 years, without a history of CRC or inflammatory bowel disease. Each participant answered ten discrete choice questions presenting two hypothetical tests comprised of four attributes: testing procedure, mortality reduction, test frequency, and complications. DCE responses were used to estimate each participant’s most important attribute and to simulate their preferred test among three existing CRC-screening tests. For each individual, we compared the DCE

  8. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  9. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    Science.gov (United States)

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  10. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  11. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    Science.gov (United States)

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. An Algorithm for Glaucoma Screening in Clinical Settings and Its Preliminary Performance Profile

    Directory of Open Access Journals (Sweden)

    S-Farzad Mohammadi

    2013-01-01

    Full Text Available Purpose: To devise and evaluate a screening algorithm for glaucoma in clinical settings. Methods: Screening included examination of the optic disc for vertical cupping (≥0.4 and asymmetry (≥0.15, Goldmann applanation tonometry (≥21 mmHg, adjusted or unadjusted for central corneal thickness, and automated perimetry. In the diagnostic step, retinal nerve fiber layer imaging was performed using scanning laser polarimetry. Performance of the screening protocol was assessed in an eye hospital-based program in which 124 non-physician personnel aged 40 years or above were examined. A single ophthalmologist carried out the examinations and in equivocal cases, a glaucoma subspecialist′s opinion was sought. Results: Glaucoma was diagnosed in six cases (prevalence 4.8%; 95% confidence interval, 0.01-0.09 of whom five were new. The likelihood of making a definite diagnosis of glaucoma for those who were screened positively was 8.5 times higher than the estimated baseline risk for the reference population; the positive predictive value of the screening protocol was 30%. Screening excluded 80% of the initial population. Conclusion: Application of a formal screening protocol (such as our algorithm or its equivalent in clinical settings can be helpful in detecting new cases of glaucoma. Preliminary performance assessment of the algorithm showed its applicability and effectiveness in detecting glaucoma among subjects without any visual complaint.

  13. Preliminary phytochemical and antimicrobial screening of 50 ...

    African Journals Online (AJOL)

    Ethanolic extracts of 50 plant species were screened for their antimicrobial activity against Bacillus subtilis, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. The results indicated that of the 50 plant extracts, 28 plant extracts inhibited the growth of one or more test pathogens.

  14. Testing Precision Screening for Breast Cancer

    Science.gov (United States)

    An NCI research article about individualized approaches that could help identify those at risk of breast cancer who need to be screened and testing screening intervals that are appropriate for each person’s level of risk.

  15. Physician-patient discussions of controversial cancer screening tests.

    Science.gov (United States)

    Dunn, A S; Shridharani, K V; Lou, W; Bernstein, J; Horowitz, C R

    2001-02-01

    Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians' likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians' belief that PSA screening is advantageous; house staff and attending physicians' intention to order a PSA test, and attending physicians' intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians' beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer.

  16. Physician–Patient Discussions of Controversial Cancer Screening Tests

    Science.gov (United States)

    Dunn, Andrew S.; Shridharani, Kanan V.; Lou, Wendy; Bernstein, Jeffrey; Horowitz, Carol R.

    2016-01-01

    Background Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. Methods We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians’ likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. Results For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians’ belief that PSA screening is advantageous; house staff and attending physicians’ intention to order a PSA test, and attending physicians’ intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Conclusions Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians’ beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer. PMID:11165455

  17. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxidase screening test for gonorrhea. 866.2420... screening test for gonorrhea. (a) Identification. An oxidase screening test for gonorrhea is an in vitro... of gonorrhea. (b) Classification. Class III (premarket approval) (transitional device). (c) Date PMA...

  18. Indicators for monitoring screening programs with primary HPV test.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo

    2017-01-01

    following scientific evidence produced in numerous studies, as well as national and international guidelines, organized cervical cancer screening programs in Italy have gradually introduced the HPV test as primary screening test, replacing cytology. As public health interventions, screening programs must ensure equity, improvement in quality of life, and adequate information for the population involved with regards to benefits and possible risks; therefore, it is essential for quality to be constantly checked at every phase of the project.The Italian Cervical Screening Group (Gruppo Italiano per lo Screening Cervicale, GISCi) has written a handbook for the calculation and interpretation of cervical screening program monitoring indicators that take into account the new protocol based on primary HPV test with cytology triage. based on the European guidelines and Italian recommendations on primary HPVbased screening, the working group, which includes professionals from all the fields involved in cervical screening, identified the essential points needed to monitor the screening process, the accuracy of individual tests, and early outcomes, defining a specific indicator for each aspect. The indicators were grouped as follows: baseline indicators, indicators for test repeat after one year, cumulative indicators, and waiting times. For every indicator, the source of data, calculation formula, any standards or critical thresholds, and interpretation were defined. The standards are based on the results of NTCC trials or Italian pilot studies. the main indicators proposed for the organization are the following: number of invitations, compliance with first invitation, with one-year test repeat and with colposcopy; for test and process accuracy, a cohort approach was utilised, where indicators are based on women who must be followed for at least one year, so as to integrate the results obtained after the first HPV test with the outcome of the test's repetition after one year

  19. Comparison of four microbiological inhibition tests for the screening of antimicrobial residues in the tissues of food-producing animals

    Directory of Open Access Journals (Sweden)

    Zuzana Gondová

    2014-10-01

    Full Text Available The study compares two existing microbiological inhibition tests, Screening Test for Antibiotic Residues (STAR and Premi®Test with two recently introduced tests, Nouws Antibiotic Test (NAT and Total Antibiotics for the screening of antimicrobial residues in the tissues of food-producing animals. In the negative or positive sample classification based on inhibition of the growth of test strain sensitive to many antibiotics and sulphonamides, out of 142 samples obtained from slaughterhouses and retail operations, 39 samples yielded a positive result in one or more tests: 4 samples in four tests, 14 samples in three tests, 13 samples in two tests, and 8 samples in one test. As for the numbers of observed positive samples, the descending sequence of tests was: STAR, Total Antibiotics, Premi®Test, NAT. The growth inhibition was observed in three out of seven test strains, namely Bacillus cereus ATCC 11778, Kocuria rhizophila ATCC 9341, and Bacillus stearothermophilus var. calidolactis. Considering the test strains sensitivity and no inhibition on the Bacillus pumilus NCIMB 10822 NAT test plates, our preliminary conclusion is that the animal samples are suspected for the presence of tetracycline, macrolide, and b-lactam antibiotics.

  20. Cold Leak Tests of LHC Beam Screens

    CERN Document Server

    Collomb-Patton, C; Jenninger, B; Kos, N

    2009-01-01

    In order to guide the high energy proton beams inside its two 27 km long vacuum rings, the Large Hadron Collider (LHC) at CERN, Geneva, makes use of superconducting technology to create the required magnetic fields. More than 4000 beam screens, cooled at 7 20 K, are inserted inside the 1.9 K beam vacuum tubes to intercept beam induced heat loads and to provide dynamic vacuum stability. As extremely high helium leak tightness is required, all beam screens have been leak tested under cold conditions in a dedicated test stand prior to their installation. After describing the beam screen design and its functions, this report focuses on the cold leak test sequence and discusses the results.

  1. Preliminary screening analysis of the off-site environment downstream of the US Department of Energy Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Blaylock, B.G.; Hoffman, F.O.; Frank, M.L.

    1990-01-01

    Operations and waste disposal activities at the Y-12 Plant, the Oak Ridge National Laboratory (ORNL), and the Oak Ridge Gaseous Diffusion Plant (ORGDP), located on the US Department of Energy (DOE) Oak Ridge Reservation (ORR) in eastern Tennessee, have introduced airborne, liquid, and solid wastes into the surrounding environment. Some of these wastes may affect off-site areas by entering local streams that ultimately drain into the Clinch River. Previously reported concentrations of radionuclides, metals, and organic compounds in water, sediment, and biota of the Clinch River and Watts Bar Reservoir suggest the presence of contaminants of possible concern to the protection of human health and the environment. A preliminary screening was conducted of contaminants in the off-site surface water environments downstream of the DOE ORR. This screening analysis represents part of a scoping phase of the Clinch River Resource Conservation and Recovery Facilities Investigation (CRRFI). The purpose of this preliminary screening analysis is to use existing data on off-site contaminant concentrations to identify and prioritize potential contaminants of concern for further evaluation and investigation. The primary objective of this screening analysis is to ensure that CRRFI sampling and analysis efforts focus on those contaminants that may possibly contribute to human health or environmental risk. 8 refs., 3 figs., 6 tabs

  2. Screening and Invasive Testing in Twins

    Directory of Open Access Journals (Sweden)

    Giovanni Monni

    2014-07-01

    Full Text Available Prenatal screening and testing for trisomy 21 in twin pregnancies poses a number of challenges: the exact estimate of the a priori risk of trisomy 21, the choice of prenatal screening test and/or invasive techniques to employ for the diagnosis and the impact of the result on the options of treatment in case of discordant results within a twin pair or among multiples. These different aspects are discussed below while recognizing that many issues remain unresolved.

  3. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    Science.gov (United States)

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Preliminary pharmacognostic screening of Achyranthes coynei stem

    Directory of Open Access Journals (Sweden)

    Vinayak Upadhya

    2015-01-01

    Full Text Available Achyranthes coynei is a rare, endemic perennial shrub reported from Karnataka and Maharashtra states of India. The plant is used to treat various disorders by folk healers and was proven to have antimicrobial and antioxidant properties. The present study was undertaken to evaluate microscopic and macroscopic characters of A. coynei stem, along with its physicochemical parameters. ProgRes ® CapturePro and Microsoft Excel were used for statistical analysis. Perennial, shrubby nature and woody stem were the distinguishing morphological characters observed. Transverse section (TS illustrated quadrangular outline of the stem and showed the presence of two types of trichomes on the thick-walled epidermis. TS also showed number of rosette calcium oxalates crystals; prismatic and microsphenoid crystals; conjoint, collateral open secondary vascular bundles; and two amphixylic medullary bundles in the pith. Ash and extractive values, micro and macro elements and nutritive factors were estimated in the present study. The presence of alkaloids, saponins and triterpenoids were observed in preliminary phytochemical screening. High-performance thin layer chromatographic analysis yielded different bands and also indicated the presence of oleanolic acid. The studied parameters for A. coynei stem will be useful for identification and authentication of the plant material.

  5. Preliminary pharmacognostic screening of Achyranthes coynei stem.

    Science.gov (United States)

    Upadhya, Vinayak; Ankad, Gireesh M; Pai, Sandeep R; Hegde, Shruti V; Hegde, Harsha V

    2015-01-01

    Achyranthes coynei is a rare, endemic perennial shrub reported from Karnataka and Maharashtra states of India. The plant is used to treat various disorders by folk healers and was proven to have antimicrobial and antioxidant properties. The present study was undertaken to evaluate microscopic and macroscopic characters of A. coynei stem, along with its physicochemical parameters. ProgRes(®) CapturePro and Microsoft Excel were used for statistical analysis. Perennial, shrubby nature and woody stem were the distinguishing morphological characters observed. Transverse section (TS) illustrated quadrangular outline of the stem and showed the presence of two types of trichomes on the thick-walled epidermis. TS also showed number of rosette calcium oxalates crystals; prismatic and microsphenoid crystals; conjoint, collateral open secondary vascular bundles; and two amphixylic medullary bundles in the pith. Ash and extractive values, micro and macro elements and nutritive factors were estimated in the present study. The presence of alkaloids, saponins and triterpenoids were observed in preliminary phytochemical screening. High-performance thin layer chromatographic analysis yielded different bands and also indicated the presence of oleanolic acid. The studied parameters for A. coynei stem will be useful for identification and authentication of the plant material.

  6. Preliminary studies on the behavioural effects of the methanol ...

    African Journals Online (AJOL)

    The behavioural tests employed were diazepam-induced sleep onset and duration, hole board assay for exploratory activity, mouse beam walk assay for motor coordination, and the staircase test for the detection of anxiolytic compounds. Preliminary phytochemical screening was also carried out on the extract. Results: The ...

  7. [Generalized neonatal screening based on laboratory tests].

    Science.gov (United States)

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    Implementation of a generalized screening program for neonatal diseases must obey precise rules. The disease must be severe, recognizable at an early stage, amenable to an effective treatment, detectable with a non expensive and widely applicable test; it must also be a significant public health problem. Subjects with positive results must be offered immediate treatment or prevention. All screening programs must be regularly evaluated. In France, since 1978, a national screening program has been organized by a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and supervised by the "Caisse nationale d'assurance maladie" and "Direction Générale de la Sante". Five diseases are now included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease (the latter only in at-risk newborns). Toxoplasmosis is a particular problem because only the children of mothers who were not tested during the pregnancy or who seroconverted are screened. Neonatal screening for phenylketonuria and hypothyrodism is unanimously recommended. Screening for congenital adrenal hyperplasia is approved in most countries. Cases of sickle cell disease and cystic fibrosis are more complex because--not all children who carry the mutations develop severe forms;--there is no curative treatment;--parents may become anxious, even though the phenotype is sometimes mild or even asymptomatic. Supporters of screening stress the benefits of early diagnosis (which extends the life expectancy of these children, particularly in the case of sickle cell disease), the fact that it opens up the possibility of prenatal screening of future pregnancies, and the utility of informing heterozygous carriers identified by familial screening. Neonatal screening for other diseases is under discussion. Indeed, technical advances such as tandem mass spectrometry make it possible to detect about 50

  8. Development and Usability Testing of a Computer-Tailored Decision Support Tool for Lung Cancer Screening: Study Protocol.

    Science.gov (United States)

    Carter-Harris, Lisa; Comer, Robert Skipworth; Goyal, Anurag; Vode, Emilee Christine; Hanna, Nasser; Ceppa, DuyKhanh; Rawl, Susan M

    2017-11-16

    follow-up survey. We expect to have results by December 31, 2017 and to have data analysis completed by March 1, 2018. Results from usability testing indicate that the computer-tailored decision support tool is easy to use, is helpful, and provides a satisfactory experience for the user. At the conclusion of phase III (pilot RCT), we will have preliminary effect sizes to inform a future fully powered RCT on changes in (1) knowledge about lung cancer and screening, (2) perceived risk of lung cancer, (3) perceived benefits of lung cancer screening, (4) perceived barriers to lung cancer screening, (5) self-efficacy for lung cancer screening, and (6) perceptions of being adequately prepared to engage in a discussion with their clinician about lung cancer screening. ©Lisa Carter-Harris, Robert Skipworth Comer, Anurag Goyal, Emilee Christine Vode, Nasser Hanna, DuyKhanh Ceppa, Susan M Rawl. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 16.11.2017.

  9. Screening Tests for Birth Defects

    Science.gov (United States)

    ... that best fit your needs. What are the advantages and disadvantages of diagnostic tests compared with screening ... Us Contact Us Copyright Information Privacy Statement RSS Advertising Opportunities Careers at ACOG Sitemap Website Feedback American ...

  10. The use of screening tests in aviation medicine

    International Nuclear Information System (INIS)

    Ruge, A.

    2000-01-01

    Pilots have to submit themselves in regular intervals to medical examinations in order to avoid a sudden incapacitation that could endanger flight safety. In Germany these examinations include screening tests to detect an illness in an early phase and to guide the pilot to keep up his/her health. European Joint Aviation Requirements have no provisions for screening tests. Under Council Directive 96/29/EURATOM flight crews in Germany will have to undergo special medical radiation protection examinations. The introduction of any screening tests that give information about individual reactions to cosmic radiation exposure are very unlikely if results are not kept confidential, as this would limit the choice of profession. Flight crews should be made aware of these tests. (orig.) [de

  11. [Comparison of eight screening tests for ant-HCV antibody].

    Science.gov (United States)

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  12. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    Science.gov (United States)

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  13. Co-Testing of Cervical Screening Tests in Detection of High Grade Cervical Intraepithelial Neoplasia

    Directory of Open Access Journals (Sweden)

    Smita Asthana

    2017-10-01

    Full Text Available Introduction: Co-testing performance for detection of high grade Cervical Intraepithelial Neoplasia (CIN has not been adequately addressed from Low Resource Countries (LRCs. Where isolated tests do not have adequate performance, further explorations are recommended. Aim: To evaluate the co-testing of conventional cervical screening tests such as Papanicolaou (Pap and Visual Inspection Cervix with Acetic Acid (VIA, with care HPV on Cervical Samples (CHPV or on Vaginal Samples (VHPV in the detection of high grade CIN. Materials and Methods: The cross-sectional study was conducted on ever married women of age 30 to 59 years in a rural community of Dadri. Women were screened by CHPV, VHPV, and Pap and VIA methods. Confirmation of screen positives was done by histology. Sensitivity, Specificity and likelihood ratios of different combinations of test determined to evaluate the performance. Results: Total eligible women, 66.2% (5032/7604 responded for screening. Analysis was performed on 4658, after excluding those who did not complete all screenings. Co-testing of CHPV (OR=246 or VHPV (OR=278 with Pap had highest association. Positive likelihood ratios of CHPV and VHPV with Pap in CIN II+ detection rates were 13.0 and 11.8 and in CIN III+ the detection rates were 18.0 and 16.0 respectively. Higher sensitivities and specificities were observed in co-testing for CIN III+ detection as against CIN II+ lesions. Conclusion: Choice of co-testing in a pair of tests for detection of high grade CIN is likely to depend on whether screening is targeted for developed or low resource country. VIA in isolation might not yield optimal results for LRCs.

  14. Unconfirmed reactive screening tests and their impact on donor management

    International Nuclear Information System (INIS)

    Rahman, M.; Khan, S.A.

    2008-01-01

    To determine the percentage of false positive testing for transfusion transmitted infections (TTIs) using immunochromatographic test (ICT) as first line of screening tests and its effect on loss of volunteer blood donors. Over a period of three months, samples from blood bags of donors undergoing phlebotomy at teaching hospital blood banks in Lahore were screened for human immunodeficiency virus (HIV), hepatitis B (HBV) and hepatitis C (HCV) by immunochromatographic tests. Those found positive on initial screening were re-tested by ELISA method at the screening laboratory of the Institute of Haematology and Blood Transfusion Service, Punjab. Lahore. Out of a total of 62090 voluntary blood donors, 469 donors were found to be initially reactive for either HIV, HBV or HCV. Amongst these 96 (0.15%) blood donors were found to have tested falsely positive for HIV, HBV or HCV as compared to testing by ELISA. False positive testing rate of 0.15% or 96 out of a total of 62090 donors is rather small in terms of loss of voluntary donors and appropriate utilization of available resources. Although immunochromatographic testing is not the gold standard, however it serves an important purpose of initial donor screening. (author)

  15. Preliminary results of ecotoxicological assessment of an Acid Mine Drainage (AMD) passive treatment system testing water quality of depurated lixiviates

    OpenAIRE

    Miguel Sarmiento, Aguasanta; Bonnail, Estefanía; Nieto Liñán, José Miguel; Valls Casillas, Tomás Ángel del

    2017-01-01

    The current work reports on the preliminary results of a toxicity test using screening experiments to check the efficiency of an innovative passive treatment plant designed for acid mine drainage purification. Bioassays took place with water samples before and after the treatment system and in the river, once treated water is discharged. Due to the high toxicity of the water collected at the mouth of the mine (before the treatment plant), the bioassay was designed and developed with respect t...

  16. Uptake of community-based, self-collected HPV testing vs. visual inspection with acetic acid for cervical cancer screening in Kampala, Uganda: preliminary results of a randomised controlled trial.

    Science.gov (United States)

    Moses, Erin; Pedersen, Heather N; Mitchell, Sheona M; Sekikubo, Musa; Mwesigwa, David; Singer, Joel; Biryabarema, Christine; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S

    2015-10-01

    To compare two cervical cancer screening methods: community-based self-collection of high-risk human papillomavirus (HR-HPV) testing and visual inspection with acetic acid (VIA). Pilot randomised controlled trial of 500 women aged 30-65 in the community of Kisenyi, Uganda. Women randomised to self-collection-based HR-HPV testing provided a cervico-vaginal swab for HR-HPV, and results were provided by phone after laboratory testing. Women who tested HPV positive were referred for VIA at the local health unit. Women randomised to VIA underwent screening at the local health unit, where women who tested positive with VIA were provided cryotherapy at time of screening, as per local standard of care. Women were referred for colposcopy when indicated. Outcome measures were uptake of screening, HR-HPV prevalence, VIA result and treatment rates. In the HR-HPV arm, 248 of 250 (p < 0.01) women provided samples, while in the VIA arm, 121 of 250 (48.4%) women attended screening. Among the 73 of 248 HR-HPV-positive women, 45.2% (N = 33) attended VIA screening for follow-up, 21.2% (N = 7) of whom screened positive; five received treatment and two were missing clinical follow-up records. Of the 121 women in the VIA arm who attended screening, 13.2% (N = 16) screened positive; seven received cryotherapy, three refused treatment, five were referred to colposcopy; and one woman had suspected cervical cancer and received treatment after confirmatory testing. This pilot study demonstrated trial feasibility and willingness of the women to participate and be randomised successfully into the two arms. Self-collection-based cervical cancer screening had a higher uptake than VIA. © 2015 John Wiley & Sons Ltd.

  17. Evaluating the evidence: direct-to-consumer screening tests advertised online.

    Science.gov (United States)

    Lovett, Kimberly M; Mackey, Timothy K; Liang, Bryan A

    2012-09-01

    Unsupervised online direct-to-consumer (DTC) access to medical services has rapidly expanded to medical screening tests, which have not been critically evaluated for their evidence basis. The objective of this study is to identify the scope of online-advertised DTC screening tests, outline the evidence for use of available DTC testing and suggest regulatory reform to address the relevant issues. An observational study of website advertisements, testing services and counselling/follow-up services for DTC testing was conducted. Data were collected from websites between 4 April and 1 June 2011. Each website was assessed for tests offered, advertised indications and availability of counselling/follow-up services. Advertised testing indications were compared with US Preventive Services Task Force recommendations and/or specialty guidelines and categorized as Supported, Against, Insufficient Evidence or No Guidance. Of 20 companies identified as offering DTC screening tests, 95% (19/20) do not clearly offer pretest counselling, post-test counselling and/or test follow-up. One hundred and twenty-seven different tests were identified. Only 19/127 (15%) could be Supported for screening in a target group selected for testing; 38/127 (30%) were given recommendations to avoid use in specific target group(s) selected for testing ('Against recommendations'); 29/127 (23%) had Insufficient Evidence of value, and for 64/127 (50%) No Guidance could be given. Only 4/127 (3%) tests were Supported for general screening use. Virtually all identified medical tests advertised and offered DTC are not recommended for use in screening by evidence-based guidelines. Limited oversight may lead to inaccurate self-diagnosis, treatment and wasted health resources.

  18. Preliminary test results for post irradiation examination on the HTTR fuel

    International Nuclear Information System (INIS)

    Ueta, Shohei; Umeda, Masayuki; Sawa, Kazuhiro; Sozawa, Shizuo; Shimizu, Michio; Ishigaki, Yoshinobu; Obata, Hiroyuki

    2007-01-01

    The future post-irradiation program for the first-loading fuel of the HTTR is scheduled using the HTTR fuel handling facilities and the Hot Laboratory in the Japan Materials Testing Reactor (JMTR) to confirm its irradiation resistance and to obtain data on its irradiation characteristics in the core. This report describes the preliminary test results and the future plan for a post-irradiation examination for the HTTR fuel. In the preliminary test, fuel compacts made with the same SiC-coated fuel particle as the first loading fuel were used. In the preliminary test, dimension, weight, fuel failure fraction, and burnup were measured, and X-ray radiograph, SEM, and EPMA observations were carried out. Finally, it was confirmed that the first-loading fuel of the HTTR showed good quality under an irradiation condition. The future plan for the post-irradiation tests was described to confirm its irradiation performance and to obtain data on its irradiation characteristics in the HTTR core. (author)

  19. Screening the nutritional status in oncology: a preliminary report on 1,000 outpatients.

    Science.gov (United States)

    Bozzetti, Federico

    2009-03-01

    This study presents the preliminary data of a prospective multi-centre investigation on the screening of the nutritional status of cancer outpatients with the purpose to define: (1) prevalence and rate of weight loss and nutritional risk in this patient population, and (2) to assess the association among some patient-dependent, tumour-dependent and therapy-dependent variables with the nutritional status and the nutritional risk. Seventeen centres were involved to collect demographic data (age and sex), oncologic data (site of primary tumour, stage, Eastern Cooperative Oncology Group Performance State, oncologic therapy) and presence and severity of systemic and digestive/nutritional symptoms (fatigue, anorexia, nausea/vomiting, early satiety, dysgeusia/dysosmia, dysphagia/odynophagia, diarrhoea/constipation). Furthermore, the percentage of the weight loss on the usual body weight and the body mass index were computed. The nutritional risk was assessed according to the Nutrition Risk Screening 2002 questionnaire which scores the risk from 0 to 7. On the first 1,000 screened patients, a significant weight loss (>or=10%) and a nutritional risk score >or=3 were observed in 39.7% and 33.8% of patients, respectively. Weight loss was higher in upper gastrointestinal tumours, in advanced stages of disease and in patients with a poor performance status. Similarly, the nutritional risk was higher in esophageal and pancreatic cancer and in those with a worse performance status. There was a good correlation between the severity of anorexia and the rate of the weight loss The majority of patients with no weight loss or a weight loss anorexia. Weight loss and nutritional risk are frequent in an unselected series of cancer outpatients. Site of primary tumour, stage and performance state appear to be associated, at a preliminary analysis, with significant weight loss and nutritional risk. Anorexia and weight loss are closely related, and this supports the concept that nutritional

  20. Methods for Rapid Screening in Woody Plant Herbicide Development

    Directory of Open Access Journals (Sweden)

    William Stanley

    2014-07-01

    Full Text Available Methods for woody plant herbicide screening were assayed with the goal of reducing resources and time required to conduct preliminary screenings for new products. Rapid screening methods tested included greenhouse seedling screening, germinal screening, and seed screening. Triclopyr and eight experimental herbicides from Dow AgroSciences (DAS 313, 402, 534, 548, 602, 729, 779, and 896 were tested on black locust, loblolly pine, red maple, sweetgum, and water oak. Screening results detected differences in herbicide and species in all experiments in much less time (days to weeks than traditional field screenings and consumed significantly less resources (<500 mg acid equivalent per herbicide per screening. Using regression analysis, various rapid screening methods were linked into a system capable of rapidly and inexpensively assessing herbicide efficacy and spectrum of activity. Implementation of such a system could streamline early-stage herbicide development leading to field trials, potentially freeing resources for use in development of beneficial new herbicide products.

  1. Breast cancer screening (BCS) chart: a basic and preliminary model for making screening mammography more productive and efficient.

    Science.gov (United States)

    Poorolajal, Jalal; Akbari, Mohammad Esmaeil; Ziaee, Fatane; Karami, Manoochehr; Ghoncheh, Mahshid

    2017-05-15

    The breast cancer screening (BCS) chart is suggested as a basic and preliminary tool to improve efficiency of screening mammography. We conducted this case-control study in 2016 and enrolled 1422 women aged 30-75 years, including 506 women with breast cancer (cases) and 916 women without breast cancer (controls). We developed the BCS chart using a multiple logistic regression analysis. We combined the risks of breast cancer to predict the individual risk of breast cancer. Then, we stratified and colored the predicted risk probabilities as follows: green), 05-09% (yellow), 10-14% (orange), 15-19% (red), 20-24% (brown) and ≥25% (black). The BCS chart provides the risk probability of breast cancer, based on age, body mass index, late menopause, having a benign breast disease and a positive family history of breast cancer among the first-degree or the second/third-degree relatives. According to this chart, an individual can be classified in a category of low risk (green), medium risk (yellow and orange), high risk (red and brown) and very high risk (black) for breast cancer. This chart is a flexible and easy to use tool that can detect high-risk subjects and make the screening program more efficient and productive. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. A randomized controlled trial of Human Papillomavirus (HPV) testing for cervical cancer screening: trial design and preliminary results (HPV FOCAL Trial)

    International Nuclear Information System (INIS)

    Ogilvie, Gina S; Cook, Darrel A; Mei, Wendy; Stuart, Gavin CE; Franco, Eduardo L; Coldman, Andrew J; Niekerk, Dirk J van; Krajden, Mel; Martin, Ruth E; Ehlen, Thomas G; Ceballos, Kathy; Peacock, Stuart J; Smith, Laurie W; Kan, Lisa

    2010-01-01

    In the HPV FOCAL trial, we will establish the efficacy of hr-HPV DNA testing as a stand-alone screening test followed by liquid based cytology (LBC) triage of hr-HPV-positive women compared to LBC followed by hr-HPV triage with ≥ CIN3 as the outcome. HPV-FOCAL is a randomized, controlled, three-armed study over a four year period conducted in British Columbia. It will recruit 33,000 women aged 25-65 through the province's population based cervical cancer screening program. Control arm: LBC at entry and two years, and combined LBC and hr-HPV at four years among those with initial negative results and hr-HPV triage of ASCUS cases; Two Year Safety Check arm: hr-HPV at entry and LBC at two years in those with initial negative results with LBC triage of hr-HPV positives; Four Year Intervention Arm: hr-HPV at entry and combined hr-HPV and LBC at four years among those with initial negative results with LBC triage of hr-HPV positive cases To date, 6150 participants have a completed sample and epidemiologic questionnaire. Of the 2019 women enrolled in the control arm, 1908 (94.5%) were cytology negative. Women aged 25-29 had the highest rates of HSIL (1.4%). In the safety arm 92.2% of women were hr-HPV negative, with the highest rate of hr-HPV positivity found in 25-29 year old women (23.5%). Similar results were obtained in the intervention arm HPV FOCAL is the first randomized trial in North America to examine hr-HPV testing as the primary screen for cervical cancer within a population-based cervical cancer screening program. International Standard Randomised Controlled Trial Number Register, ISRCTN79347302

  3. A randomized controlled trial of Human Papillomavirus (HPV testing for cervical cancer screening: trial design and preliminary results (HPV FOCAL Trial

    Directory of Open Access Journals (Sweden)

    Smith Laurie W

    2010-03-01

    Full Text Available Abstract Background In the HPV FOCAL trial, we will establish the efficacy of hr-HPV DNA testing as a stand-alone screening test followed by liquid based cytology (LBC triage of hr-HPV-positive women compared to LBC followed by hr-HPV triage with ≥ CIN3 as the outcome. Methods/Design HPV-FOCAL is a randomized, controlled, three-armed study over a four year period conducted in British Columbia. It will recruit 33,000 women aged 25-65 through the province's population based cervical cancer screening program. Control arm: LBC at entry and two years, and combined LBC and hr-HPV at four years among those with initial negative results and hr-HPV triage of ASCUS cases; Two Year Safety Check arm: hr-HPV at entry and LBC at two years in those with initial negative results with LBC triage of hr-HPV positives; Four Year Intervention Arm: hr-HPV at entry and combined hr-HPV and LBC at four years among those with initial negative results with LBC triage of hr-HPV positive cases Discussion To date, 6150 participants have a completed sample and epidemiologic questionnaire. Of the 2019 women enrolled in the control arm, 1908 (94.5% were cytology negative. Women aged 25-29 had the highest rates of HSIL (1.4%. In the safety arm 92.2% of women were hr-HPV negative, with the highest rate of hr-HPV positivity found in 25-29 year old women (23.5%. Similar results were obtained in the intervention arm HPV FOCAL is the first randomized trial in North America to examine hr-HPV testing as the primary screen for cervical cancer within a population-based cervical cancer screening program. Trial Registration International Standard Randomised Controlled Trial Number Register, ISRCTN79347302

  4. Screening for Malnutrition in Community Dwelling Older Japanese: Preliminary Development and Evaluation of the Japanese Nutritional Risk Screening Tool (NRST).

    Science.gov (United States)

    Htun, N C; Ishikawa-Takata, K; Kuroda, A; Tanaka, T; Kikutani, T; Obuchi, S P; Hirano, H; Iijima, K

    2016-02-01

    Early and effective screening for age-related malnutrition is an essential part of providing optimal nutritional care to older populations. This study was performed to evaluate the adaptation of the original SCREEN II questionnaire (Seniors in the Community: Risk Evaluation for Eating and Nutrition, version II) for use in Japan by examining its measurement properties and ability to predict nutritional risk and sarcopenia in community-dwelling older Japanese people. The ultimate objective of this preliminary validation study is to develop a license granted full Japanese version of the SCREEN II. The measurement properties and predictive validity of the NRST were examined in this cross-sectional study of 1921 community-dwelling older Japanese people. Assessments included medical history, and anthropometric and serum albumin measurements. Questions on dietary habits that corresponded to the original SCREEN II were applied to Nutritional Risk Screening Tool (NRST) scoring system. Nutritional risk was assessed by the Geriatric Nutrition Risk Index (GNRI) and the short form of the Mini-Nutritional Assessment (MNA-SF). Sarcopenia was diagnosed according to the criteria of the European Working Group on Sarcopenia in Older People. The nutritional risk prevalences determined by the GNRI and MNA-SF were 5.6% and 34.7%, respectively. The prevalence of sarcopenia was 13.3%. Mean NRST scores were significantly lower in the nutritionally at-risk than in the well-nourished groups. Concurrent validity analysis showed significant correlations between NRST scores and both nutritional risk parameters (GNRI or MNA-SF) and sarcopenia. The areas under the receiver operating characteristic curves (AUC) of NRST for the prediction of nutritional risk were 0.635 and 0.584 as assessed by GNRI and MNA-SF, respectively. AUCs for the prediction of sarcopenia were 0.602 (NRST), 0.655 (age-integrated NRST), and 0.676 (age and BMI-integrated NRST). These results indicate that the NRST is a

  5. Screening for gestational diabetes: examining a breakfast meal test ...

    African Journals Online (AJOL)

    Objective: This study was performed to analyse the carbohydrate quantity of the non-standardised breakfast meal test consumed as part of a screening test for gestational diabetes. Design: A prospective descriptive design was utilised. Setting: Screening for gestational diabetes was performed in the High-Risk Antenatal ...

  6. [Mass neonatal screening using biological testing].

    Science.gov (United States)

    Ardaillou, R; Le Gall, J-Y

    2007-04-01

    Implementation of a generalized screening program for neonatal diseases obeys precise guidelines. The disease must be severe, recognizable at an early stage, accessible to an effective treatment, detected with a non expansive and widely applicable test and it must represent an important health problem. In case of positive results, treatment or prevention shall be offered immediately and any screening program has to be regularly evaluated. There is in France since 1978 a national screening program that depends on a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and is supervised by the "Caisse nationale d'assurance maladie" and the "Direction Générale de la Sante". Presently, five diseases are included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease, the latter only in at risk newborns. Toxoplasmosis represents a particular problem because screening takes place only in children of mothers that have not been controlled during their pregnancy or in case of seroconversion. Neonatal screening of phenylketonuria and hypothyrodism is unanimously recommended. That of congenital adrenal hyperplasia is approved in most countries. The cases of sickle cell disease and cystic fibrosis are more complex because: 1) all the children that carry the mutations are not affected with a severe disease; 2) there is no curative treatment; 3) parents given information are made anxious, sometimes wrongly if the disease is mild or asymptomatic. The supporters of the screening insist on the interest of an early diagnosis which makes longer the life time of these children, the possibility for the parents to utilize prenatal screening in case of a future pregnancy, and the information given to the heterozygous carriers following a familial screening. The question is raised of the extension of neonatal screening to other diseases. This is now

  7. Development of a computer-based automated pure tone hearing screening device: a preliminary clinical trial.

    Science.gov (United States)

    Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah

    2012-10-01

    Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.

  8. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries.

    Science.gov (United States)

    Frati, Elena Rosanna; Martinelli, Marianna; Fasoli, Ester; Colzani, Daniela; Bianchi, Silvia; Binda, Sandro; Olivani, Pierfranco; Tanzi, Elisabetta

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56-99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88-99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28-100) at both time points. The concordance between DUS and fresh urine HPV testing was "almost perfect" using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  9. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    Directory of Open Access Journals (Sweden)

    Elena Rosanna Frati

    2015-01-01

    Full Text Available Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV testing from dried urine spots (DUS. Eighty-eight urine samples (including 56 HPV DNA positive specimens were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68 for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01 for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100 at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries.

  10. HPV Testing from Dried Urine Spots as a Tool for Cervical Cancer Screening in Low-Income Countries

    Science.gov (United States)

    Olivani, Pierfranco

    2015-01-01

    Nowadays, several screening strategies are available to prevent cervical cancer, but inadequate resources, sociocultural barriers, and sampling issues impede their success in low-income countries. To overcome these issues, this study aimed to evaluate the performance of human papillomavirus (HPV) testing from dried urine spots (DUS). Eighty-eight urine samples (including 56 HPV DNA positive specimens) were spotted on filter paper, dried, and stored in paper-bags. HPV DNA was detected from the DUS after 1 week and 4 weeks of storage using a polymerase chain reaction (PCR) assay. The sensitivity, specificity, and concordance of the DUS-based HPV test were evaluated by comparing the results with those of HPV testing on fresh urine samples as the gold standard. The sensitivity of the test was 98.21% (95% CI: 90.56–99.68) for DUS stored for 1 week and 96.42% (95% CI: 87.88–99.01) for DUS stored for 4 weeks. The specificity was 100% (95% CI: 89.28–100) at both time points. The concordance between DUS and fresh urine HPV testing was “almost perfect” using the κ statistic. These preliminary data suggest that a DUS-based assay could bypass sociocultural barriers and sampling issues and therefore could be a suitable, effective tool for epidemiological surveillance and screening programs, especially in low-income countries. PMID:26180790

  11. Augmented Reality Cubes for Cognitive Gaming: Preliminary Usability and Game Experience Testing

    Directory of Open Access Journals (Sweden)

    Costas Boletsis

    2016-03-01

    Full Text Available Early detection is important in dementia care; however, cognitive impairment is still under-recognised and under-diagnosed. Cognitive screening and training are two important preventative treatments, which can lead to early detection of cognitive decline. In this work, the “Cognitive Augmented Reality Cubes” (CogARC system is presented, i.e. a serious game for cognitive training and screening, utilising an interaction technique based on Augmented Reality and the manipulation of tangible, physical objects (cubes. The game is a collection of cognitive mini-games of preventative nature and is, primarily, targeting elderly players (≥60 years old. A preliminary testing was conducted focusing on the game experience that CogARC offers (utilising the In-Game Experience Questionnaire, the usability of the system (using the System Usability Scale, and the specific user observations and remarks, as documented by open, semi-structured interviews.  Overall, CogARC demonstrated satisfying positive responses, however, the negative reactions indicated that there are specific problems with aspects of the interaction technique and a number of mini-games. The open interview shed more light on the specific issues of each mini-game and further interpretation of user interactions. The current study managed to provide interesting insights into the game design elements, integration of Augmented Reality, tangible interaction of the system, and on how elderly players perceive and use those interaction components. 

  12. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    Science.gov (United States)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  13. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  14. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  15. Computerized visuo-spatial memory test as a supplementary screening test for dementia.

    Science.gov (United States)

    Maki, Yohko; Yoshida, Hiroshi; Yamaguchi, Haruyasu

    2010-06-01

    To prepare for a super-aging society, effective dementia screening tests are required. The most salient deficit appearing from the early stages of dementia/Alzheimer's disease (AD) is a deterioration in memory. The Hasegawa Dementia Scale-revised (HDS-R) and the Mini-Mental State Examination (MMSE) are widely used in Japan to screen for dementia. Both place an emphasis on memory function, but neither examines visuo-spatial memory (VSM) function, even though VSM deficits are a sensitive marker for the detection of conversion to dementia. Furthermore, brief tests of VSM that are appropriate for screening have not been standardized. Thus, in the present study, we devised a brief, computer-aided short-term VSM test. Sixty-six aged people were evaluated. Using the Clinical Dementia Rating (CDR), it was found that 29 could be considered normal controls (NC; CDR 0), 10 had mild cognitive impairment (MCI; CDR 0.5), 15 had mild dementia (CDR 1), and 12 had moderate to severe dementia (CDR 2-3). The VSM test estimated how many locations each subject could memorize. Several numbered circles were shown on a monitor and subjects were required to memorize the location of these circles sequentially. After the numbers on the circles on the screen had disappeared, the subjects were required to indicate the circles in ascending order. A touch panel screen was used for this test to make it easier. The HDS-R was applied to subjects with MCI and dementia. The mean (+/-SD) VSM score in subjects with MCI (5.70 +/- 0.96) was significantly lower than that in NC subjects (6.69 +/- 0.82), but significantly higher than that in subjects classified as CDR 1 (4.67 +/- 0.87). There was no significant difference in VSM scores between subjects classified as CDR 1 and CDR 2-3 (3.80 +/- 0.80). There was a moderate significant correlation between VSM and HDS-R scores. In the present study, the VSM test detected differences in VSM function among NC subjects and subjects with MCI and mild dementia. The

  16. Astrophysical tests of gravity: a screening map of the nearby universe

    Energy Technology Data Exchange (ETDEWEB)

    Cabré, Anna; Vikram, Vinu; Jain, Bhuvnesh [Center for Particle Cosmology, Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104-6396 (United States); Zhao, Gong-Bo; Koyama, Kazuya, E-mail: annanusca@gmail.com, E-mail: vinu@sas.upenn.edu, E-mail: gong-bo.zhao@port.ac.uk, E-mail: bjain@physics.upenn.edu, E-mail: Kazuya.Koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth, PO1 3FX (United Kingdom)

    2012-07-01

    Astrophysical tests of modified gravity theories in the nearby universe have been emphasized recently by Hui 2009 and Jain 2011. A key element of such tests is the screening mechanism whereby general relativity is restored in massive halos or high density environments like the Milky Way. In chameleon theories of gravity, including all f(R) models, field dwarf galaxies may be unscreened and therefore feel an extra force, as opposed to screened galaxies. The first step to study differences between screened and unscreened galaxies is to create a 3D screening map. We use N-body simulations to test and calibrate simple approximations to determine the level of screening in galaxy catalogs. Sources of systematic errors in the screening map due to observational inaccuracies are modeled and their contamination is estimated. We then apply our methods to create a map out to 200 Mpc in the Sloan Digital Sky Survey footprint using data from the Sloan survey and other sources. In two companion papers this map will be used to carry out new tests of gravity using distance indicators and the disks of dwarf galaxies. We also make our screening map publicly available.

  17. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    Science.gov (United States)

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  19. Preliminary pharmacological screening of Bixa orellana L. leaves.

    Science.gov (United States)

    Shilpi, Jamil Ahmad; Taufiq-Ur-Rahman, Md; Uddin, Shaikh Jamal; Alam, Md Shahanur; Sadhu, Samir Kumar; Seidel, Véronique

    2006-11-24

    Preliminary pharmacological studies were performed on the methanol extract of Bixa orellana L. (Bixaceae) leaves to investigate neuropharmacological, anticonvulsant, analgesic, antidiarrhoeal activity and effect on gastrointestinal motility. All studies were conducted in mice using doses of 125, 250 and 500 mg/kg of body weight. In the pentobarbitone-induced hypnosis test, the extract statistically reduced the time for the onset of sleep at 500 mg/kg dose and (dose-dependently) increased the total sleeping time at 250 and 500 mg/kg dose. A statistically significant decrease in locomotor activity was observed at all doses in the open-field and hole-cross tests. In the strychnine-induced anticonvulsant test, the extract increased the average survival time of the test animals (statistically significant at 250 and 500 mg/kg). The extract significantly and dose-dependently reduced the writhing reflex in the acetic acid-induced writhing test. Antidiarrhoeal activity was supported by a statistically significant decrease in the total number of stools (including wet stools) in castor oil-induced diarrhoea model. A statistically significant delay in the passage of charcoal meal was observed at 500 mg/kg in the gastrointestinal motility test. The extract was further evaluated in vitro for antioxidant and antibacterial activity. It revealed radical scavenging properties in the DPPH assay (IC(50)=22.36 microg/ml) and antibacterial activity against selected causative agents of diarrhoea and dysentery, including Shigella dysenteriae.

  20. Seismic proving test of ultimate piping strength (current status of preliminary tests)

    International Nuclear Information System (INIS)

    Suzuki, K.; Namita, Y.; Abe, H.; Ichihashi, I.; Suzuki, K.; Ishiwata, M.; Fujiwaka, T.; Yokota, H.

    2001-01-01

    In 1998 Fiscal Year, the 6 year program of piping tests was initiated with the following objectives: i) to clarify the elasto-plastic response and ultimate strength of nuclear piping, ii) to ascertain the seismic safety margin of the current seismic design code for piping, and iii) to assess new allowable stress rules. In order to resolve extensive technical issues before proceeding on to the seismic proving test of a large-scale piping system, a series of preliminary tests of materials, piping components and simplified piping systems is intended. In this paper, the current status of the material tests and the piping component tests is reported. (author)

  1. Targeted prostate cancer screening in men with mutations in BRCA1 and BRCA2 detects aggressive prostate cancer: preliminary analysis of the results of the IMPACT study

    DEFF Research Database (Denmark)

    Mitra, Anita V; Bancroft, Elizabeth K; Barbachano, Yolanda

    2011-01-01

    mutations were offered annual prostate specific antigen (PSA) testing, and those with PSA >3 ng/mL, were offered a prostate biopsy. Controls were men age-matched (± 5 years) who were negative for the familial mutation. RESULTS: In total, 300 men were recruited (205 mutation carriers; 89 BRCA1, 116 BRCA2......Study Type - Diagnostic (validating cohort)
Level of Evidence 1b OBJECTIVES: To evaluate the role of targeted prostate cancer screening in men with BRCA1 or BRCA2 mutations, an international study, IMPACT (Identification of Men with a genetic predisposition to ProstAte Cancer: Targeted screening...... in BRCA1/2 mutation carriers and controls), was established. This is the first multicentre screening study targeted at men with a known genetic predisposition to prostate cancer. A preliminary analysis of the data is reported. MATERIALS AND METHODS: Men aged 40-69 years from families with BRCA1 or BRCA2...

  2. Preliminary design of the beam screen cooling for the Future Circular Collider of hadron beams

    CERN Document Server

    Kotnig, C

    2015-01-01

    Following recommendations of the recent update of the European strategy in particle physics, CERN has undertaken an international study of possible future circular colliders beyond the LHC. This study considers an option for a very high energy (100 TeV) hadron-hadron collider located in a quasi-circular underground tunnel having a circumference of 80 to 100 km. The synchrotron radiation emitted by the high-energy hadron beam increases by more than two orders of magnitude compared to the LHC. To reduce the entropic load on the superconducting magnets' refrigeration system, beam screens are indispensable to extract the heat load at a higher temperature level. After illustrating the decisive constraints of the beam screen's refrigeration design, this paper presents a preliminary design of the length of a continuous cooling loop comparing helium and neon, for different cooling channel geometries with emphasis on the cooling length limitations and the exergetic efficiency.

  3. Preliminary design of the beam screen cooling for the Future Circular Collider of hadron beams

    Science.gov (United States)

    Kotnig, C.; Tavian, L.

    2015-12-01

    Following recommendations of the recent update of the European strategy in particle physics, CERN has undertaken an international study of possible future circular colliders beyond the LHC. This study considers an option for a very high energy (100 TeV) hadron-hadron collider located in a quasi-circular underground tunnel having a circumference of 80 to 100 km. The synchrotron radiation emitted by the high-energy hadron beam increases by more than two orders of magnitude compared to the LHC. To reduce the entropic load on the superconducting magnets’ refrigeration system, beam screens are indispensable to extract the heat load at a higher temperature level. After illustrating the decisive constraints of the beam screen's refrigeration design, this paper presents a preliminary design of the length of a continuous cooling loop comparing helium and neon, for different cooling channel geometries with emphasis on the cooling length limitations and the exergetic efficiency.

  4. Human papillomavirus testing and genotyping in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Lynge, Elsebeth; Bonde, Jesper

    2011-01-01

    the incidence of cervical cancer, but has a low sensitivity for high-grade cervical intraepithelial neoplasia (CIN) and requires frequent testing. Several HPV tests have become available commercially. They appear to be more sensitive for high-grade CIN, and may further reduce the incidence of cervical cancer......Mass vaccination against human papillomavirus (HPV) genotypes 16 and 18 will, in the long term, reduce the incidence of cervical cancer, but screening will remain an important cancer control measure in both vaccinated and unvaccinated women. Since the 1960s, cytology screening has helped to reduce...

  5. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  6. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    Science.gov (United States)

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  7. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  8. 42 CFR 410.18 - Diabetes screening tests.

    Science.gov (United States)

    2010-10-01

    ... screening tests. (a) Definitions. For purposes of this section, the following definitions apply: Diabetes... receive the benefit: (1) Hypertension. (2) Dyslipidemia. (3) Obesity, defined as a body mass index greater...

  9. GRIST-2 preliminary test plan and requirements for fuel fabrication and preirradiation

    International Nuclear Information System (INIS)

    Tang, I.M.; Harmon, D.P.; Torri, A.

    1978-12-01

    The preliminary version of the GRIST-2 test plan has been developed for the planned initial 5 years (1984 to 1989) of TREAT-Upgrade in-pile tests. These tests will be employed to study the phenomenology and integral behavior of GCFR core disruptive accidents (CDAs) and to support the Final Safety Analysis Report (FSAR) CDA analyses for the demonstration plant licensing. The preliminary test plan is outlined. Test Phases I and II are for the fresh fuel (preconditioned or not) CDA behavior at the beginning-of-life (BOL) reactor state. Phase III is for the reactor state that contains irradiated fuel with a saturated content of helium and fission gas. Phase IV is for larger bundle tests and scaling effects

  10. Mammography-based screening program: preliminary results from a first 2-year round in a Brazilian region using mobile and fixed units

    Directory of Open Access Journals (Sweden)

    Haikel Raphael

    2012-10-01

    Full Text Available Abstract Background Breast cancer is the most frequently diagnosed cancer and the leading cause of cancer deaths among women worldwide. The use of mobile mammography units to offer screening to women living in remote areas is a rational strategy to increase the number of women examined. This study aimed to evaluate results from the first 2 years of a government-organized mammography screening program implemented with a mobile unit (MU and a fixed unit (FU in a rural county in Brazil. The program offered breast cancer screening to women living in Barretos and the surrounding area. Methods Based on epidemiologic data, 54 238 women, aged 40 to 69 years, were eligible for breast cancer screening. The study included women examined from April 1, 2003 to March 31, 2005. The chi-square test and Bonferroni correction analyses were used to evaluate the frequencies of tumors and the importance of clinical parameters and tumor characteristics. Significance was set at p Results Overall, 17 964 women underwent mammography. This represented 33.1% of eligible women in the area. A mean of 18.6 and 26.3 women per day were examined in the FU and MU, respectively. Seventy six patients were diagnosed with breast cancer (41 (54% in the MU. This represented 4.2 cases of breast cancer per 1000 examinations. The number of cancers detected was significantly higher in women aged 60 to 69 years than in those aged 50 to 59 years (p Conclusions Preliminary results indicate that this mammography screening program is feasible for implementation in a rural Brazilian territory and favor program continuation.

  11. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  12. A preliminary investigation of the imaging performance of photostimulable phosphor computed radiography using a new design of mammographic quality control test object

    International Nuclear Information System (INIS)

    Cowen, A.R.; Brettle, D.S.; Coleman, N.J.; Parkin, G.J.S.

    1992-01-01

    Leeds Test Object TOR[MAM] has been designed to supplement the current FAXIL mammography test object TOR[MAX]. It contains a range of details that have a more natural radiographic appearance and has been designed as a test that more closely approximates the image quality achieved in clinical mammography. Physical aspects of the design and implementation of TOR[MAM] are presented. The TOR[MAM] has been used in a preliminary physical evaluation of the comparative image qualities produced by conventional (screen-film) and phostostimulable phosphor computed mammography and the results are discussed. TOR[MAX] results are also presented. The influence of digital image processing (enhancement) on the image quality of computed mammograms is also considered. The results presented indicate the sensitivity of TOR[MAM]. (author)

  13. Preliminary Tests of a New Low-Cost Photogrammetric System

    Science.gov (United States)

    Santise, M.; Thoeni, K.; Roncella, R.; Sloan, S. W.; Giacomini, A.

    2017-11-01

    This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B) single board computer connected to a PiCamera Module V2 (8 MP) and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  14. PRELIMINARY TESTS OF A NEW LOW-COST PHOTOGRAMMETRIC SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Santise

    2017-11-01

    Full Text Available This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B single board computer connected to a PiCamera Module V2 (8 MP and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  15. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  16. Advances in prenatal screening for Down syndrome: II first trimester testing, integrated testing, and future directions.

    Science.gov (United States)

    Benn, Peter A

    2002-10-01

    The acceptability of prenatal screening and diagnosis of Down syndrome is dependent, in part, on the gestational age at which the testing is offered. First trimester screening could be advantageous if it has sufficient efficacy and can be effectively delivered. Two first trimester maternal serum screening markers, pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (beta-hCG), are useful for identifying women at increased risk for fetal Down syndrome. In addition, measurement of an enlarged thickness of the subcutaneous fluid-filled space at the back of the neck of the developing fetus (referred to as nuchal translucency or NT) has been demonstrated to be an indicator for these high-risk pregnancies. When these three parameters are combined, estimates for Down syndrome efficacy exceed those currently attainable in the second trimester. Women who are screen-positive in the first trimester can elect to receive cytogenetic testing of a chorionic villus biopsy. The first trimester tests could also, theoretically, be combined with the second trimester maternal serum screening tests (integrated screening) to obtain even higher levels of efficacy. There are, however, several practical limitations to first trimester and integrated screening. These include scheduling of testing within relatively narrow gestational age intervals, availability of appropriately trained ultrasonographers for NT measurement, risks associated with chorionic villus biopsy, and costs. There is also increasing evidence that an enlarged NT measurement is indicative of a high risk for spontaneous abortion and for fetal abnormalities that are not detectable by cytogenetic analysis. Women whose fetuses show enlarged NT, therefore, need first trimester counseling regarding their Down syndrome risks and the possibility of other adverse pregnancy outcomes. Follow-up ultrasound and fetal echocardiography in the second trimester are also indicated. First trimester

  17. Preliminary project of installation for separation tubes tests-ITTS

    International Nuclear Information System (INIS)

    Rocha, Z.

    1984-01-01

    A consolidation of actual ideas about installation, entitled ''Installation to separation tubes tests-ITTS'', expected to CDTN is presented. The project bases, the testing to be realized, the procedures to be obeyed during the operation, the components and the space required by installation and auxiliary equipments, the presumable origin of components (nacional and international), including a preliminary list of building and operation costs are described. (author) [pt

  18. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  19. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    Science.gov (United States)

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  20. Do doctors understand the test characteristics of lung cancer screening?

    Science.gov (United States)

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  1. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  2. Developments and the preliminary tests of Resistive GEMs manufactured by a screen printing technology

    CERN Document Server

    Agócs, G; Oliveira, R; Martinego, P; Peskov, Vladimir; Pietropaolo, P; Picchi, P

    2008-01-01

    We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with ordinary GEM-like detectors with metallic electrodes; however, due to the high resistivity of its electrodes the RETGEM, in contrast to ordinary hole-type detectors, has the advantage of being fully spark protected. We discovered that RETGEMs can operate stably and at high gains in noble gases and in other badly quenched gases, such as mixtures of noble gases with air and in pure air; therefore, a wide range of practical applications, including dosimetry and detection of dangerous gases, is foreseeable. To promote a better understanding of RETGEM technology some comparative studies were completed with metallic-electrode thick GEMs. A primary benefit of these new RETGEMs is that the screen printing technology is easily accessible to many research laboratories. This accessibilit...

  3. Cancer screening using 18F-FDG PET/CT in Korean asymptomatic volunteers. A preliminary report

    International Nuclear Information System (INIS)

    Lee, Jeong-Won; Kang, Keon-Wook; Paeng, Jin-Chul; Lee, Sang-Mi; Jang, Su-Jin; Chung, June-Key; Lee, Myung-Chul; Lee, Dong-Soo

    2009-01-01

    This study was performed to evaluate the clinical value of 18 F-fluorodeoxyglucose (FDG) positron-emission tomography (PET)/computed tomography (CT) for cancer screening in Korean asymptomatic people. Between February 2004 and December 2006, 1,587 asymptomatic individuals underwent FDG PET/CT as part of a cancer screening program with some other diagnostic tests at the healthcare center of our hospital. After excluding patients with a history of malignant tumor, 1,336 subjects were enrolled. All PET/CT images were visually analyzed. In subjects showing positive findings for PET/CT or other screening tests, further diagnostic tests and pathological confirmation were performed. Of the 1,336 subjects, malignant tumors were found in 16 participants (1.2%, thyroid cancer: 9, lung cancer: 2, stomach cancer: 2, and others: 4). There were 47 cases (3.6%) of positive PET/CT findings- 11 cases were true positive (thyroid cancer: 8, lung cancer: 1, renal cancer: 1, and invasive thymoma), and 36 false positive, and five cases were false negative. The overall detection rate of PET/CT was 0.8%, and the sensitivity, specificity, positive-predictive value, and negative-predictive value of PET/CT were 68.8, 97.2, 23.4, and 99.6%, respectively. Fluorodeoxyglucose positron-emission tomography has the potential to detect various kinds of malignant tumors in cancer screening test, and the overall detection rate of PET/CT was 0.8%. FDG PET/CT can be a useful cancer screening modality with the selection of high-risk group and appropriate combination with other screening modalities. (author)

  4. The clinical utility of HPV DNA testing in cervical cancer screening strategies.

    Science.gov (United States)

    Bhatla, Neerja; Moda, Nidhi

    2009-09-01

    Cervical cancer continues to be the commonest cause of death among women in developing countries, largely due to the failure to the inability to sustain effective cytology-based screening programs. While this burden may come down following implementation of the human papillomavirus (HPV) vaccine, screening will still be required. HPV DNA testing is a promising new technology for cervical cancer prevention and is the most reproducible of all cervical cancer screening tests. Presently, the two assays most widely used for the detection of genital types are the polymerase chain reaction (PCR) and Hybrid Capture 2 assays (hc2). Rapid, affordable tests are expected to be available soon. HPV DNA testing can be used in a variety of clinical scenarios that include primary screening in women older than 30 yr; as an adjunctive test to cytology; in the triage of women with an equivocal cytologic report, e.g., ASC-US; or for follow-up post-treatment for cervical intraepithelial neoplasia (CIN). HPV DNA testing can also be performed on self-collected samples, which allows screening in remote areas and also in women who refuse gynecologic examination.

  5. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  6. Alkaline phosphatase as a screening test for osteomalacia.

    Science.gov (United States)

    Chinoy, Muhammad Amin; Javed, Muhammad Imran; Khan, Alamzeb; Sadruddin, Nooruddin

    2011-01-01

    Vitamin D deficiency remains common in children and adults in Pakistan despite adequate sunlight exposure. Diagnosis in adults is usually delayed and is made following pathological fractures that result in significant morbidity. The objective of this study was to see whether Serum Alkaline Phosphatase levels could be used as a screening test for osteomalacia. The Study was conducted at Fatima Hospital, Baqai Medical University, Gadap, Karachi, between July 2002 and June 2005. Serum calcium levels are commonly used to screen patients suspected of osteomalacia, and raised serum alkaline phosphatase (SALP) is considered a diagnostic finding. We used SALP to screen patients who presented with back or non-specific aches and pain of more than six months duration. Three hundred thirty-four (334) patients were screened of which 116 (35%) had raised SALP. Osteomalacia was diagnosed in 92 (79.3%) of these 116 either by plain radiographs, bone biopsy or isotope bone scan. Fifty-four (53.4%) of the 101 cases had a normal level of serum calcium. Osteomalacia is likely to be missed if only serum calcium is used to screen patients. Serum Alkaline Phosphate should be used as the preferred method for screening these patients.

  7. Perceived effectiveness of HPV test as a primary screening modality among US providers.

    Science.gov (United States)

    Cooper, Crystale Purvis; Saraiya, Mona

    2015-09-01

    The human papillomavirus (HPV) test, administered alone without the Papanicolaou (Pap) test, was recently recognized as a cervical cancer screening option in the United States by the Society of Gynecologic Oncology and the American Society for Colposcopy and Cervical Pathology, and the Food and Drug Administration has approved an HPV test for primary screening. Surveys of US internists, family practitioners, nurse practitioners, and obstetrician-gynecologists were conducted in 2009 and 2012 to investigate providers' perceptions of the effectiveness of the HPV test administered alone as a population-based screening modality (2009: N=1040, 141-494 per provider group; 2012: N=1039, 155-435 per provider group). The majority in each provider group agreed that the HPV test administered alone is an effective screening modality in 2009 (75.3%-86.1%) and 2012 (79.5%-91.8%), and agreement rose significantly during this time period among family practitioners (χ(2)=15.26, df=1, ptest administered alone is an effective cervical cancer screening modality was widespread among providers in both 2009 and 2012, however implementation of guidelines for screening with the HPV test may be influenced by many other factors including reimbursement and patient preferences. Published by Elsevier Inc.

  8. Does offering prenatal screening influence pregnant women's attitudes regarding prenatal testing?

    NARCIS (Netherlands)

    Kleinveld, J.H.; van den Berg, M.; van Eijk, J.T.; van Vugt, J.M.G.; van der Wal, G.; Timmermans, D.R.M.

    2008-01-01

    Objectives: This study aims to find out whether offering prenatal screening for Down syndrome and neural tube defects influences pregnant women's attitudes toward having a screening test. Methods: Women were randomised into a group that was offered prenatal screening and a group that was not offered

  9. A population screening test for antibody to measles virus

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1981-01-01

    In areas where sporadic cases of measles continue to occur in spite of vaccination programs, the availability of a simple screening test for determination of seropositivity to measles virus is desirable. A sensitive radioimmunoassay (RIA) screening test (ST) for the detection of IgG antibody to measles virus, based on a solid phase RIA, is described. The assays were performed on polyvinyl microtiter plates for which the RIAST requires only 5 μl of serum per subject. Antigen consisted of a sonicated extract of measles virus-infected Vero cells. Rabbit antihuman IgG specific for the Fc-segment of human IgG, labelled with 125 I, was used to detect human IgG bound to viral antigen. The basic RIA method was characterized by carrying out full titrations of sera of 53 healthy adults, 10 children, and 13 patients with measles-associated illness. These sera were also tested by the hemagglutination inhibition (HI) technique; most of the measles sera were also tested by complement fixation (CF). RIAST results (expressed as binding ratios) obtained for 52 healthy adults are compared with their RIA serum titers. Of the 200 sera of patients of various ages tested by the RIAST, 63 borderline sera were also tested by HI. The RIAST, which does not require serum treatment other than inactivation, proved to be more sensitive as an indicator of seropositivity than HI. Implications of the results and practical applications of the screening test are discussed. (author)

  10. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    Science.gov (United States)

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  11. Screening for suppression in young children: the Polaroid Suppression test

    NARCIS (Netherlands)

    Pott, J.W.R.; Oosterveen, DK; Van Hof-van Duin, J

    1998-01-01

    Background: Assessment of monocular visual impairment during screening of young children is often hampered by lack of cooperation. Because strabismus, amblyopia, or anisometropia may lead to monocular suppression during binocular viewing conditions, a test was developed to screen far suppression in

  12. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  13. The Clinical and Economic Benefits of Co-Testing Versus Primary HPV Testing for Cervical Cancer Screening: A Modeling Analysis.

    Science.gov (United States)

    Felix, Juan C; Lacey, Michael J; Miller, Jeffrey D; Lenhart, Gregory M; Spitzer, Mark; Kulkarni, Rucha

    2016-06-01

    Consensus United States cervical cancer screening guidelines recommend use of combination Pap plus human papillomavirus (HPV) testing for women aged 30 to 65 years. An HPV test was approved by the Food and Drug Administration in 2014 for primary cervical cancer screening in women age 25 years and older. Here, we present the results of clinical-economic comparisons of Pap plus HPV mRNA testing including genotyping for HPV 16/18 (co-testing) versus DNA-based primary HPV testing with HPV 16/18 genotyping and reflex cytology (HPV primary) for cervical cancer screening. A health state transition (Markov) model with 1-year cycling was developed using epidemiologic, clinical, and economic data from healthcare databases and published literature. A hypothetical cohort of one million women receiving triennial cervical cancer screening was simulated from ages 30 to 70 years. Screening strategies compared HPV primary to co-testing. Outcomes included total and incremental differences in costs, invasive cervical cancer (ICC) cases, ICC deaths, number of colposcopies, and quality-adjusted life years for cost-effectiveness calculations. Comprehensive sensitivity analyses were performed. In a simulation cohort of one million 30-year-old women modeled up to age 70 years, the model predicted that screening with HPV primary testing instead of co-testing could lead to as many as 2,141 more ICC cases and 2,041 more ICC deaths. In the simulation, co-testing demonstrated a greater number of lifetime quality-adjusted life years (22,334) and yielded $39.0 million in savings compared with HPV primary, thereby conferring greater effectiveness at lower cost. Model results demonstrate that co-testing has the potential to provide improved clinical and economic outcomes when compared with HPV primary. While actual cost and outcome data are evaluated, these findings are relevant to U.S. healthcare payers and women's health policy advocates seeking cost-effective cervical cancer screening

  14. Willingness to take a screening test for colorectal cancer: a community-based survey in Malaysia.

    Science.gov (United States)

    Naing, Cho; Jun, Yip Kar; Yee, Wai Mun; Waqiyuddin, Syazana J D B T; Lui, Lau Chiew; Shaung, Ooi Yin; Haw, Fong Jenn

    2014-03-01

    The aims of the study were (i) to determine the knowledge and perceptions of colorectal cancer (CRC), (ii) to explore the willingness of the study population to take a screening test for CRC, and (iii) to identify factors affecting the willingness to take a screening test for CRC. A cross-sectional survey was carried out in a semiurban town in Malaysia using a pretested structured questionnaire. Descriptive statistics were determined for all important variables. A binary logistic regression model was introduced to identify independent predictors of the willingness to take a screening test. Factors influencing willingness were explored according to the constructs of the health belief model. Of the 256 respondents who had heard about CRC, the majority were aware of altered bowel habits (67.3%) or the presence of blood in stool or rectal bleeding (63.4%) as the warning symptoms. Although 38% of the respondents knew of colonoscopy as the screening test, 22% were not aware of any screening test for CRC. A majority (77.4%) showed willingness to take a screening test for CRC. In the multivariate analysis, 'having family or friends with history of CRC' and 'self-perceived risk' were the two significant variables for predicting the acceptance of CRC screening among the study population. Findings suggested that the respondents' knowledge of the CRC screening test was inadequate, albeit a high proportion expressed their intention to take screening tests. Health education on the CRC addressing available screening tests and the benefits of early screening for CRC should be scaled up.

  15. A rapid and simple screening test to detect the radiation treatment of fat-containing foods

    International Nuclear Information System (INIS)

    Delincee, H.

    1993-01-01

    In recent years several international efforts have been made to develop analytical detection methods for the radiation treatment of foods. A number of methods has indeed been developed. Particularly, for fat-containing foods several methods are already in an advanced stage. In addition to the sophisticated techniques such as gas chromatography/mass spectrometry which require relatively expensive equipment and/or extended sample preparation time, it would be desirable to have quick and simple screening tests, which immediately on-the-spot give some indication whether a food product has been irradiated or not. A solution to this problem for lipid-containing foods has been put forward by Furuta and co-workers (1991, 1992), who estimated the amount of carbon monoxide originating from the lipid fraction in poultry meat after irradiation. The carbon monoxide was expelled from the frozen meat by quick microwave heating and in the head space of the sample, the formed carbon monoxide was determined by gas chromatography. In order to speed up time of analysis, we have used an electrochemical CO sensor, as also is being used to estimate CO in ambient air in workplaces, to determine the CO content in the vapor expelled from the irradiated samples. This CO test is very simple, cheap and easy to perform. It takes only a few minutes to screen food samples for evidence of their having been radiation processed. If doubts concerning the radiation treatment of a sample arise, the more sophisticated - and expensive -methods for analyzing lipid-containing foods can be applied. Certainly the test is limited to food products which contain a certain amount of fat. A preliminary test with lean shrimps showed practically no difference between irradiated (2.5 and 5 kGy) and non-irradiated samples. By relating CO production to the fat content, possibly a better parameter for classification can be obtained. (orig./vhe)

  16. A single-question screening test for drug use in primary care.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2010-07-12

    Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.

  17. Knowledge and attitude of women regarding breast cancer screening tests in Eastern Iran.

    Science.gov (United States)

    Izanloo, Azra; Ghaffarzadehgan, Kamran; Khoshroo, Fahimeh; Erfani Haghiri, Maryam; Izanloo, Sara; Samiee, Mohadeseh; Tabatabaei, Alireza; Mirshahi, Azadeh; Fakoor, Morteza; Moghadam, Najmeh Jafari; Sadrzadeh, Sayyed Majid

    2018-01-01

    According to recent statistics, there has been a rapid growth of breast cancer in developing countries. Thus, early detection is essential. This study is based on the perception of people in the Northeast of Iran regarding breast cancer screening. In a cross-sectional study, 1469 women were selected randomly in the period from April to November 2016. The study population consisted of women or their companions referring to outpatient clinics or people in public urban areas who filled out a breast cancer screening questionnaire in an interview. The patients' age was in the range of 14 to 84 years (mean = 38.8). More than 84% of interviewees were not informed of breast cancer and screening tests. The main reasons mentioned by patients for their failure to do screening tests was 'absence of any symptom or problem' and 'they did not think it was necessary'.There was not a significant difference between income level, marital status and knowledge of people about breast cancer screening tests (P > 0.05). However, employment, education level and family history had a positive effect on people's awareness of breast cancer and its screening tests (P economic classes was the main barrier to breast cancer screening. In this regard, organizing training programs by physicians and the media can help raise screening rates.

  18. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    Science.gov (United States)

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  19. Incidence of interval cancers in faecal immunochemical test colorectal screening programmes in Italy.

    Science.gov (United States)

    Giorgi Rossi, Paolo; Carretta, Elisa; Mangone, Lucia; Baracco, Susanna; Serraino, Diego; Zorzi, Manuel

    2018-03-01

    Objective In Italy, colorectal screening programmes using the faecal immunochemical test from ages 50 to 69 every two years have been in place since 2005. We aimed to measure the incidence of interval cancers in the two years after a negative faecal immunochemical test, and compare this with the pre-screening incidence of colorectal cancer. Methods Using data on colorectal cancers diagnosed in Italy from 2000 to 2008 collected by cancer registries in areas with active screening programmes, we identified cases that occurred within 24 months of negative screening tests. We used the number of tests with a negative result as a denominator, grouped by age and sex. Proportional incidence was calculated for the first and second year after screening. Results Among 579,176 and 226,738 persons with negative test results followed up at 12 and 24 months, respectively, we identified 100 interval cancers in the first year and 70 in the second year. The proportional incidence was 13% (95% confidence interval 10-15) and 23% (95% confidence interval 18-25), respectively. The estimate for the two-year incidence is 18%, which was slightly higher in females (22%; 95% confidence interval 17-26), and for proximal colon (22%; 95% confidence interval 16-28). Conclusion The incidence of interval cancers in the two years after a negative faecal immunochemical test in routine population-based colorectal cancer screening was less than one-fifth of the expected incidence. This is direct evidence that the faecal immunochemical test-based screening programme protocol has high sensitivity for cancers that will become symptomatic.

  20. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  1. Experiences with a self-test for Dutch breast screening radiologists: lessons learnt

    NARCIS (Netherlands)

    Timmers, J. M. H.; Verbeek, A. L. M.; Pijnappel, R. M.; Broeders, M. J. M.; den Heeten, G. J.

    2014-01-01

    To evaluate a self-test for Dutch breast screening radiologists introduced as part of the national quality assurance programme. A total of 144 radiologists were invited to complete a test-set of 60 screening mammograms (20 malignancies). Participants assigned findings such as location, lesion type

  2. Standard test method for conducting friction tests of piston ring and cylinder liner materials under lubricated conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures for conducting laboratory bench-scale friction tests of materials, coatings, and surface treatments intended for use in piston rings and cylinder liners in diesel or spark-ignition engines. The goal of this procedure is to provide a means for preliminary, cost-effective screening or evaluation of candidate ring and liner materials. A reciprocating sliding arrangement is used to simulate the contact that occurs between a piston ring and its mating liner near the top-dead-center position in the cylinder where liquid lubrication is least effective, and most wear is known to occur. Special attention is paid to specimen alignment, running-in, and lubricant condition. 1.2 This test method does not purport to simulate all aspects of a fired engine’s operating environment, but is intended to serve as a means for preliminary screening for assessing the frictional characteristics of candidate piston ring and liner material combinations in the presence of fluids that behave as u...

  3. Which neuromuscular or cognitive test is the optimal screening tool to predict falls in frail community-dwelling older people?

    Science.gov (United States)

    Shimada, Hiroyuki; Suzukawa, Megumi; Tiedemann, Anne; Kobayashi, Kumiko; Yoshida, Hideyo; Suzuki, Takao

    2009-01-01

    risk of falls in frail older people. When feasibility and validity were considered, the CWS was the best test for use as a screening tool in frail older people, however, these preliminary results require confirmation in further research. Copyright 2009 S. Karger AG, Basel.

  4. Screening of lettuce germplasm for agronomic traits under low water conditions

    Science.gov (United States)

    After a preliminary screening of over 3,500 varieties, we selected 200 cultivars of butterhead, cos, crisphead, leaf, and stem lettuce (Lactuca sativa L.) and wild prickly lettuce (Lactuca serriola L.) to test under high water (150% ET) and low water (50% ET) conditions in the field, and tracked com...

  5. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  6. Testing the Untestable: A Vision Screening Program for Exceptional Children.

    Science.gov (United States)

    Bishop, Virginia E.; Godolphin, Vivienne

    Based on a longitudinal study of vision screening techniques for handicapped children at the Chester County (Pennsylvania) Child Development Center, the paper reports on the development of a battery of effective vision screening methods for children with low functioning handicapped children. Specific tests are described, including the Sheridan…

  7. Preliminary Test for Nonlinear Input Output Relations in SISO Systems

    DEFF Research Database (Denmark)

    Knudsen, Torben

    2000-01-01

    This paper discusses and develops preliminary statistical tests for detecting nonlinearities in the deterministic part of SISO systems with noise. The most referenced method is unreliable for common noise processes as e.g.\\ colored. Therefore two new methods based on superposition and sinus input...

  8. Preliminary test results and CFD analysis for moderator circulation test at Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.T. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of); Im, S.H.; Sung, H.J. [Korea Advanced Inst. of Science and Tech., Daejeon (Korea, Republic of); Seo, H.; Bang, I.C. [Ulsan National Inst. of Science and Tech., Ulsan (Korea, Republic of)

    2014-07-01

    Korea Atomic Energy Research Institute (KAERI) is carrying out a scaled-down moderator test program to simulate the CANDU6 moderator circulation phenomena during steady state operation and accident conditions. This research program includes the construction of the Moderator Circulation Test (MCT) facility, production of the validation data for self-reliant CFD tools, and development of optical measurement system using the Particle Image Velocimetry (PIV). The MCT facility includes a primary circulation loop (pipe lines, a primary side pump, a heat exchanger, valves, flow meters) and a secondary side loop (pipe lines, a secondary side pump, and an external cooling tower). The loop leakage test and non-heating test are performed in the present work. In the present work the PIV technique is used to measure the velocity distributions in the scaled moderator tank of MCT under iso-thermal test conditions. The preliminary PIV measurement data are obtained and compared with CFX code predictions. (author)

  9. Preliminary test results and CFD analysis for moderator circulation test at Korea

    International Nuclear Information System (INIS)

    Kim, H.T.; Im, S.H.; Sung, H.J.; Seo, H.; Bang, I.C.

    2014-01-01

    Korea Atomic Energy Research Institute (KAERI) is carrying out a scaled-down moderator test program to simulate the CANDU6 moderator circulation phenomena during steady state operation and accident conditions. This research program includes the construction of the Moderator Circulation Test (MCT) facility, production of the validation data for self-reliant CFD tools, and development of optical measurement system using the Particle Image Velocimetry (PIV). The MCT facility includes a primary circulation loop (pipe lines, a primary side pump, a heat exchanger, valves, flow meters) and a secondary side loop (pipe lines, a secondary side pump, and an external cooling tower). The loop leakage test and non-heating test are performed in the present work. In the present work the PIV technique is used to measure the velocity distributions in the scaled moderator tank of MCT under iso-thermal test conditions. The preliminary PIV measurement data are obtained and compared with CFX code predictions. (author)

  10. Iterative Cellular Screening System for Nanoparticle Safety Testing

    Directory of Open Access Journals (Sweden)

    Franziska Sambale

    2015-01-01

    Full Text Available Nanoparticles have the potential to exhibit risks to human beings and to the environment; due to the wide applications of nanoproducts, extensive risk management must not be neglected. Therefore, we have constructed a cell-based, iterative screening system to examine a variety of nanoproducts concerning their toxicity during development. The sensitivity and application of various cell-based methods were discussed and proven by applying the screening to two different nanoparticles: zinc oxide and titanium dioxide nanoparticles. They were used as benchmarks to set up our methods and to examine their effects on mammalian cell lines. Different biological processes such as cell viability, gene expression of interleukin-8 and heat shock protein 70, as well as morphology changes were investigated. Within our screening system, both nanoparticle suspensions and coatings can be tested. Electric cell impedance measurements revealed to be a good method for online monitoring of cellular behavior. The implementation of three-dimensional cell culture is essential to better mimic in vivo conditions. In conclusion, our screening system is highly efficient, cost minimizing, and reduces the need for animal studies.

  11. The possible effects on socio-economic inequalities of introducing HPV-testing as primary test in cervical cancer screening programs.

    Directory of Open Access Journals (Sweden)

    Paolo eGiorgi Rossi

    2014-02-01

    Full Text Available Background HPV-test is more effective than Pap test in preventing cervical cancer. HPV-based screening will imply longer intervals and a triage test for HPV positive women. It will also permit the use of self-sampling devices. These innovations may affect population coverage, participation, and compliance to protocols, and likely in a different way for less educated, poorer, and disadvantaged women. Aim To describe the impact on inequalities, actual or presumed, of the introduction of HPV-based screening. Methods The putative HPV-based screening algorithm has been analysed to identify critical points for inequalities. A systematic review of the literature has been conducted searching PubMed on HPV screening coverage, participation, and compliance. Results were summarised in a narrative synthesis. Results Knowledge about HPV and cervical cancer was lower in women with low Socio-economic status and in disadvantaged groups. A correct communication can reduce differences. Longer intervals will make it easier to achieve high-population coverage, but higher cost of the test in private providers could reduce the use of opportunistic screening by disadvantaged women. There are some evidences that inviting for HPV test instead of Pap increases participation, but there are no data on social differences. Self-sampling devices are effective in increasing participation and coverage. Some studies showed that the acceptability of self-sampling is higher in more educated women, but there is also an effect on hard-to-reach women. Communication of HPV positivity may increase anxiety and impact on sexual behaviours, the effect is stronger in low educated and disadvantaged women. Many studies found indirect evidence that unvaccinated women are or will be more probably under-screened. Conclusions The introduction of HPV test may increase population coverage, but non-compliance to protocols and interaction with opportunistic screening can increase existing

  12. Preliminary hazard analysis for the Brayton Isotope Ground Demonstration System (including vacuum test chamber)

    International Nuclear Information System (INIS)

    Miller, L.G.

    1975-01-01

    The Preliminary Hazard Analysis (PHA) of the BIPS-GDS is a tabular summary of hazards and undesired events which may lead to system damage or failure and/or hazard to personnel. The PHA reviews the GDS as it is envisioned to operate in the Vacuum Test Chamber (VTC) of the GDS Test Facility. The VTC and other equipment which will comprise the test facility are presently in an early stage of preliminary design and will undoubtedly undergo numerous changes before the design is frozen. The PHA and the FMECA to follow are intended to aid the design effort by identifying areas of concern which are critical to the safety and reliability of the BIPS-GDS and test facility

  13. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study.

    Science.gov (United States)

    Campbell, Rona; Mills, Nicola; Sanford, Emma; Graham, Anna; Low, Nicola; Peters, Tim J

    2006-04-25

    The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham) were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  14. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study

    Directory of Open Access Journals (Sweden)

    Low Nicola

    2006-04-01

    Full Text Available Abstract Background The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. Methods 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Results Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Conclusion Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  15. Fluorescent screens and image processing for the APS linac test stand

    International Nuclear Information System (INIS)

    Berg, W.; Ko, K.

    1992-01-01

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image

  16. Smartphone-based audiometric test for screening hearing loss in the elderly.

    Science.gov (United States)

    Abu-Ghanem, Sara; Handzel, Ophir; Ness, Lior; Ben-Artzi-Blima, Miri; Fait-Ghelbendorf, Karin; Himmelfarb, Mordechai

    2016-02-01

    Hearing loss is widespread among the elderly. One of the main obstacles to rehabilitation is identifying individuals with potentially correctable hearing loss. Smartphone-based hearing tests can be administered at home, thus greatly facilitating access to screening. This study evaluates the use of a smartphone application as a screening tool for hearing loss in individuals aged ≥ 65 years. Twenty-six subjects aged 84.4 ± 6.73 years (mean ± SD) were recruited. Pure-tone audiometry was administered by both a smartphone application (uHear for iPhone, v1.0 Unitron, Canada) and a standard portable audiometer by trained personnel. Participants also completed a questionnaire on their hearing. Pure-tone thresholds were compared between the two testing modalities and correlated with the questionnaire results. The cutoff point for failing screening tests was a pure tone average of 40 dB for the frequencies 250-6,000 Hz. The smartphone application's pure tone thresholds were higher (poorer hearing) than the audiometric thresholds, with a significant difference in all frequencies but 2,000 Hz. The application and the audiometric values were in agreement for 24 subjects (92 %). The application had a sensitivity of 100 % and specificity of 60 % for screening compared with the audiometer. The questionnaire was significantly less accurate, having assigned a passing score to three participants who failed both the application and audiometric tests. While a smartphone application may not be able to accurately determine the level of hearing impairment, it is useful as a highly accessible portable audiometer substitute for screening for hearing loss in elderly populations.

  17. Validation of the Cross-Cultural Alcoholism Screening Test (CCAST).

    Science.gov (United States)

    Gorenc, K D; Peredo, S; Pacurucu, S; Llanos, R; Vincente, B; López, R; Abreu, L F; Paez, E

    1999-01-01

    When screening instruments that are used in the assessment and diagnosis of alcoholism of individuals from different ethnicities, some cultural variables based on norms and societal acceptance of drinking behavior can play an important role in determining the outcome. The accepted diagnostic criteria of current market testing are based on Western standards. In this study, the Munich Alcoholism Test (31 items) was the base instrument applied to subjects from several Hispanic-American countries (Bolivia, Chile, Ecuador, Mexico, and Peru). After the sample was submitted to several statistical procedures, these 31 items were reduced to a culture-free, 31-item test named the Cross-Cultural Alcohol Screening Test (CCAST). The results of this Hispanic-American sample (n = 2,107) empirically demonstrated that CCAST measures alcoholism with an adequate degree of accuracy when compared to other available cross-cultural tests. CCAST is useful in the diagnosis of alcoholism in Spanish-speaking immigrants living in countries where English is spoken. CCAST can be used in general hospitals, psychiatric wards, emergency services and police stations. The test can be useful for other professionals, such as psychological consultants, researchers, and those conducting expertise appraisal.

  18. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Directory of Open Access Journals (Sweden)

    Humza J Tahir

    Full Text Available Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  19. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Science.gov (United States)

    Tahir, Humza J; Murray, Ian J; Parry, Neil R A; Aslam, Tariq M

    2014-01-01

    Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  20. Preliminary results of a test of a longitudinal phase-space monitor

    International Nuclear Information System (INIS)

    Kikutani, Eiji; Funakoshi, Yoshihiro; Kawamoto, Takashi; Mimashi, Toshihiro

    1994-01-01

    A prototype of a longitudinal phase-space monitor has been developed in TRISTAN Main Ring at KEK. The principle of the monitor and its basic components are explained. Also a result of a preliminary beam test is given. (author)

  1. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  2. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    Science.gov (United States)

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  3. Tandem walking as a quick screening test for vestibular disorders.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2017-12-11

    Although many screening tests of balance are available, few of them have been well validated for clinical or research uses. The goal of this study was to test an updated version of an old test, Tandem Walking, to determine how useful it is for screening patients with vestibular disorders. Case-control study. Subjects were 90 adult patients with vestibular disorders and 292 healthy adult controls. They were tested on the number of correct tandem steps they could perform with arms crossed and eyes closed in a series of 10 steps. Correct steps could be nonconsecutive. Subjects were given one practice trial with eyes open and three experimental trials with eyes closed. Receiver operating characteristic (ROC), and sensitivity and specificity were calculated. ROC values, sensitivity, and specificity were, at best, only moderate, no matter how the age range was cut. Even for subjects in the age group with the highest ROC value (i.e., age less than 50 years), ROC = 0.8, sensitivity = 0.77, and specificity = 0.72. These results indicate that 23% of patients will not be identified. Therefore, we recommend that if this test is used for screening patients in the clinic or healthy volunteers, the result should be interpreted with care. 3b Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Hanford ferrocyanide waste chemistry and reactivity preliminary catalyst and initiator screening studies

    International Nuclear Information System (INIS)

    Scheele, R.D.; Bryan, S.A.; Johnston, J.W.; Tingey, J.M.; Burger, L.L.; Hallen, R.T.

    1992-05-01

    During the 1950s, ferrocyanide was used to scavenge radiocesium from aqueous nitrate-containing Hanford wastes. During the production of defense materials and while these wastes were stored in high-level waste tanks at the Hanford Site, some of these wastes were likely mixed with other waste constituents and materials. Recently, Pacific Northwest Laboratory (PNL) was commissioned by Westinghouse Hanford Company (WHC) to investigate the chemical reactivity of these ferrocyanide-bearing wastes. Because of known or potential thermal reactivity hazards associated with ferrocyanide- and nitrate-bearing wastes, and because of the potential for different materials to act as catalysts or initiators of the reactions about which there is concern, we at PNL have begun investigating the effects of the other potential waste constituents. This report presents the results of a preliminary screening study to identify classes of materials that might be in the Hanford high-level waste tanks and that could accelerate or reduce the starting temperature of the reaction(s) of concern. We plan to use the resulted of this study to determine which materials or class of materials merit additional research

  5. The impact of screening-test negative samples not enumerated by MPN

    DEFF Research Database (Denmark)

    Corbellini, Luis Gustavo; Ribeiro Duarte, Ana Sofia; de Knegt, Leonardo

    2015-01-01

    that includes false negative results from the screening, and a third that considers the entire data set. The relative sensitivity of the screening test was also calculated assuming as gold standard samples with confirmed Salmonella. Salmonella was confirmed by a reference laboratory in 29 samples either...

  6. Preliminary tests on a new near-infrared continuous-wave tissue oximeter

    Science.gov (United States)

    Casavola, Claudia; Cicco, Giuseppe; Pirrelli, Anna; Lugara, Pietro M.

    2000-11-01

    We present a preliminary study, in vitro and in vivo, with a novel device for near-infrared tissue oximetry. The light sources used are two quasi-continuous-wave LEDs, emitting at 656 and 851 nm, and the detector is a photodiode. The data are acquired in back-scattering configuration, thus allowing the non-invasive characterization of thick tissues. Stability tests were performed by placing the optical probe on a tissue- like phantom and acquiring data for periods of time ranging from 5 to 40 minutes. No significant drifts in the DC signal were observed after a warm-up period of no more than 10 minutes. We performed reproducibility tests by repositioning the optical probe on the phantom for a number of times. We found a reproducibility better than 5% in the DC signal. We also present the results of a preliminary study conducted in vivo, on the calf muscle of human subjects. We report a comparison of the results obtained with the near-infrared oximeter with the values of blood oxygenation ctO2 measured with conventional chemical tests.

  7. Mammography and Pap test screening among low-income foreign-born Hispanic women in the USA

    Directory of Open Access Journals (Sweden)

    Fernandez Maria E.

    1998-01-01

    Full Text Available Little is known about the factors influencing screening among low-income Hispanic women particularly among recent immigrants. A sample of 148 low-income, low-literate, foreign-born Hispanic women residing in the Washington DC metropolitan area participated in the study. The mean age of the sample was 46.2 (SD = 11.5, 84% reported annual household incomes<=$15,000. All women were Spanish speakers and had low acculturation levels. Ninety six percent had reported having a Pap smear, but 24% were not in compliance with recommended screening (Pap test within the last 3 years. Among women 40 and older, 62% had received a mammogram, but only 33% were compliant with age appropriate recommended mammography screening guidelines. Women in this study had more misconceptions about cancer than Hispanics in other studies. Multivariate logistic models for correlates of Pap test and mammography screening behavior indicate that factors such as fear of the screening test, embarrassment, and lack of knowledge influenced screening behavior. In conclusion, women in this study had lower rates of mammography screening than non-Hispanic women and lower rates of compliance with recommended Mammography and Pap test screening guidelines.

  8. Preliminary Test on Hydraulic Rotation Device for Neutron Transmutation Doping

    International Nuclear Information System (INIS)

    Park, Ki-Jung; Kang, Han-Ok; Kim, Seong Hoon; Park, Cheol

    2014-01-01

    The Korea Atomic Energy Research Institute (KAERI) is developing a new Research Reactor (KJRR) which will be located at KIJANG in the south-eastern province of Korea. The KJRR will be mainly utilized for isotope production, NTD production, and the related research activities. During the NTD process, the irradiation rig containing the silicon ingot rotates at the constant speed to ensure precisely defined homogeneity of the irradiation. A new NTD Hydraulic Rotation Device (NTDHRD) is being developed to rotate the irradiation rigs at the required speed. In this study, the preliminary test and the analysis for the rotation characteristic of the NTDHRD, which is developed through the conceptual design, are described. A new NTD hydraulic rotation device is being developed for the purpose of application to the KIJANG research reactor (KJRR). The preliminary test and analysis for the rotation characteristic of the NTDHRD, which is developed through the conceptual design, are conducted in experimental apparatus. The film thickness by the thrust bearing is measured and the minimum required mass flow rate for stable rotation is determined

  9. Cost-Effectiveness of Cervical Cancer Screening With Human Papillomavirus DNA Testing and HPV-16,18 Vaccination

    Science.gov (United States)

    Goldhaber-Fiebert, Jeremy D.; Stout, Natasha K.; Salomon, Joshua A.; Kuntz, Karen M.; Goldie, Sue J.

    2011-01-01

    Background The availability of human papillomavirus (HPV) DNA testing and vaccination against HPV types 16 and 18 (HPV-16,18) motivates questions about the cost-effectiveness of cervical cancer prevention in the United States for unvaccinated older women and for girls eligible for vaccination. Methods An empirically calibrated model was used to assess the quality-adjusted life years (QALYs), lifetime costs, and incremental cost-effectiveness ratios (2004 US dollars per QALY) of screening, vaccination of preadolescent girls, and vaccination combined with screening. Screening varied by initiation age (18, 21, or 25 years), interval (every 1, 2, 3, or 5 years), and test (HPV DNA testing of cervical specimens or cytologic evaluation of cervical cells with a Pap test). Testing strategies included: 1) cytology followed by HPV DNA testing for equivocal cytologic results (cytology with HPV test triage); 2) HPV DNA testing followed by cytology for positive HPV DNA results (HPV test with cytology triage); and 3) combined HPV DNA testing and cytology. Strategies were permitted to switch once at age 25, 30, or 35 years. Results For unvaccinated women, triennial cytology with HPV test triage, beginning by age 21 years and switching to HPV testing with cytology triage at age 30 years, cost $78 000 per QALY compared with the next best strategy. For girls vaccinated before age 12 years, this same strategy, beginning at age 25 years and switching at age 35 years, cost $41 000 per QALY with screening every 5 years and $188 000 per QALY screening triennially, each compared with the next best strategy. These strategies were more effective and cost-effective than screening women of all ages with cytology alone or cytology with HPV triage annually or biennially. Conclusions For both vaccinated and unvaccinated women, age-based screening by use of HPV DNA testing as a triage test for equivocal results in younger women and as a primary screening test in older women is expected to be more

  10. The use of screening tests in spacecraft lubricant evaluation

    Science.gov (United States)

    Kalogeras, Chris; Hilton, Mike; Carre, David; Didziulis, Stephen; Fleischauer, Paul

    1993-01-01

    A lubricant screening test fixture has been devised in order to satisfy the need to obtain lubricant performance data in a timely manner. This fixture has been used to perform short-term tests on potential lubricants for several spacecraft applications. The results of these tests have saved time by producing qualitative performance rankings of lubricant selections prior to life testing. To date, this test fixture has been used to test lubricants for 3 particular applications. The qualitative results from these tests have been verified by life test results and have provided insight into the function of various anti-wear additives.

  11. Terrestrial avoidance behaviour tests as screening tool to assess soil contamination

    International Nuclear Information System (INIS)

    Loureiro, Susana; Soares, Amadeu M.V.M.; Nogueira, Antonio J.A.

    2005-01-01

    To assess soil quality and risk assessment, bioassays can be useful tools to gauge the potential toxicity of contaminants focusing on their bioavailable fraction. A rapid and sublethal avoidance behaviour test was used as a screening tool with the earthworm Eisenia andrei and the isopod Porcellionides pruinosus, where organisms were exposed during 48 h to several chemicals (lindane, dimethoate and copper sulphate, for isopods and carbendazim, benomyl, dimethoate and copper sulphate for earthworms). Both species were also exposed to soils from an abandoned mine. For all bioassays a statistical approach was used to derive EC 50 values. Isopods and earthworms were able to perceive the presence of toxic compounds and escaping from contaminated to clean soil. Furthermore the behaviour parameter was equally or more sensitive then other sublethal parameters (e.g. reproduction or growth), expressing the advantages of Avoidance Behaviour Tests as screening tools in ERA. - Avoidance Behaviour Tests with earthworms and isopods can be used as screening tools in the evaluation of soil contamination

  12. Participation in prenatal screening tests and intentions concerning selective termination in Finnish maternity care

    DEFF Research Database (Denmark)

    Santalahti, P; Hemminki, E; Aro, A R

    1999-01-01

    AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS: Questionnai......AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS...... as a routine procedure. Most women (92%) underwent serum screening and most (86%) found the decision to participate or not easy. In almost every aspect of presentation and participation studied, serum and ultrasound screening differed from each other. 85% of respondents to ultrasound screening answered...... in screening and with intentions about selective termination, women's perceptions of lives of the disabled should receive more attention in future studies....

  13. Cost-Effectiveness of Primary HPV Testing, Cytology and Co-testing as Cervical Cancer Screening for Women Above Age 30 Years.

    Science.gov (United States)

    Jin, Xian Wen; Lipold, Laura; Foucher, Julie; Sikon, Andrea; Brainard, Jennifer; Belinson, Jerome; Schramm, Sarah; Nottingham, Kelly; Hu, Bo; Rothberg, Michael B

    2016-11-01

    Cervical cancer screening guidelines for women aged ≥30 years allow for co-testing or primary cytology testing. Our objective was to determine the test characteristics and costs associated with Cytology, HPV and Co-testing screening strategies. Retrospective cohort study of women undergoing cervical cancer screening with both cytology and HPV (Hybrid Capture 2) testing from 2004 to 2010 in an integrated health system. The electronic health record was used to identify women aged ≥30 years who had co-testing. Unsatisfactory or unavailable test results and incorrectly ordered tests were excluded. The main outcome was biopsy-proven cervical intraepithelial neoplasia grade 3 or higher (CIN3+). The final cohort consisted of 99,549 women. Subjects were mostly white (78.4 %), married (70.7 %), never smokers (61.3 %) and with private insurance (86.1 %). Overall, 5121 (5.1 %) tested positive for HPV and 6115 (6.1 %) had cytology ≥ ASCUS; 1681 had both and underwent colposcopy and 310 (0.3 %) had CIN3+. Sensitivity for CIN3+ was 91.9 % for Primary Cytology, 99.4 % for Co-testing, and 94.8 % for Primary HPV; specificity was 97.3 % for Co-testing and Primary Cytology and 97.9 % for Primary HPV. Over a 3-year screening interval, Primary HPV detected more cases of CIN3+ and was less expensive than Primary Cytology. Co-testing detected 14 more cases of CIN3+ than Primary HPV, but required an additional 100,277 cytology tests and 566 colposcopies at an added cost of $2.38 million, or $170,096 per additional case detected. Primary HPV was more effective and less expensive than Primary Cytology. Primary HPV screening appears to represent a cost-effective alternative to Co-testing.

  14. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks

    Directory of Open Access Journals (Sweden)

    Otani Marcia M.

    2003-01-01

    Full Text Available OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV concomitantly using two different enzyme immunoassay (EIA tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo, which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4% had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58% did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great

  15. Preliminary results of the round-robin testing of F82H

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, K.; Yamanouchi, N.; Tohyama, A.

    1996-10-01

    Preliminary results of metallurgical, physical and mechanical properties of low activation ferritic steel F82H (IEA heat) were obtained in the round-robin test in Japan. The properties of IEA heat F82H were almost the same as the original F82H.

  16. Medical and lay attitudes towards genetic screening and testing in Finland

    DEFF Research Database (Denmark)

    Toiviainen, Hanna; Jallinoja, Piia; Aro, Arja R

    2003-01-01

    The purpose of this study was to compare physicians', midwives' and lay people's attitudes towards genetic screening and testing to find out whether medical education and experience influence attitudes of genetic screening and testing. The study was based on comparison of answers to joint questions...... in three different cross-sectional postal surveys between October 1996 and April 1998 in Finland. Target groups were physicians (study base n=772, response rate 74%, including gynaecologists, paediatricians, general practitioners and clinical geneticists), midwives and public health nurses (collectively...

  17. Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain

    Science.gov (United States)

    2015-12-01

    determined that shielding the screen from solar gains was the best way to avoid monitor failure. In order to accomplish this Hot Mirror glass from...side of the monitor in order to shield the monitor from the solar loading. 2.7 Test 7 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass , 1 Inch...method to shield the screen from solar loading. The Hot Mirror glass uses a glass substrate with a coating on 1 side that passes visible light, but

  18. Phytochemical screening and antiproliferative effects of methanol ...

    African Journals Online (AJOL)

    Preliminary Phytochemical screening. Thin layer chromatographic profile (TLC) of methanol crude extract and antiproliferative studies were carried out in this research. Phytochemical screening revealed the presence of carbohydrate, glycoside, anthraquinone, steroid, triterpenes, saponin, tannins, flavonoids and alkaloid.

  19. Screening diagnostics of antivital experiences and propensity toward impulsive, autoagressive behavior in adolescents (preliminary results

    Directory of Open Access Journals (Sweden)

    Bannikov G.S.,

    2014-08-01

    Full Text Available Development of methods for revealing antivital experiences and propensity to autoaggressive behavior in educational institutions is one of the key steps in developing strategies for the primary prevention of suicidal behavior in adolescents. The purpose of this study was to develop an effective screening diagnostic package aimed at identifying antivital experiences and propensity to autoaggressive behavior. The survey methods we used were: Beck Hopelessness Scale, Russell Loneliness Scale, A.G. Shmelev Suicide Risk Questionnaire, PDQ-IV Borderline disorder and Narcissism scales. At the first stage we examined 750 minors aged 12-18 and identified risk group (85 people – 11.4%, which included adolescents with high levels of both individual scales, and their combination. At the second stage we examined 10 adolescents at risk. In 7 of them (70% were identified antivital, suicidal thoughts of passive or compulsive nature, signs of subjective and objective socio- psychological maladjustment. Our preliminary conclusion is that high levels of hopelessness and loneliness in adolescents are stable predictors of mental and emotional distress and psychosocial maladjustment in the period of psychological crises and decompensation of character accentuation of borderline and narcissistic types. These scales can be recommended for primary screening of antivital (depressive experiences and propensity to autoaggressive behavior in adolescents.

  20. Preliminary design for hot dirty-gas control-valve test facility. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    This report presents the results of a preliminary design and cost estimating effort for a facility for the testing of control valves in Hot Dirty Gas (HDGCV) service. This design was performed by Mittelhauser Corporation for the United States Department of Energy's Morgantown Energy Technology Center (METC). The objective of this effort was to provide METC with a feasible preliminary design for a test facility which could be used to evaluate valve designs under simulated service conditions and provide a technology data base for DOE and industry. In addition to the actual preliminary design of the test facility, final design/construction/operating schedules and a facility cost estimate were prepared to provide METC sufficient information with which to evaluate this design. The bases, assumptions, and limitations of this study effort are given. The tasks carried out were as follows: METC Facility Review, Environmental Control Study, Gas Generation Study, Metallurgy Review, Safety Review, Facility Process Design, Facility Conceptual Layout, Instrumentation Design, Cost Estimates, and Schedules. The report provides information regarding the methods of approach used in the various tasks involved in the completion of this study. Section 5.0 of this report presents the results of the study effort. The results obtained from the above-defined tasks are described briefly. The turnkey cost of the test facility is estimated to be $9,774,700 in fourth quarter 1979 dollars, and the annual operating cost is estimated to be $960,000 plus utilities costs which are not included because unit costs per utility were not available from METC.

  1. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-01-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler…

  2. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  3. The picture test of separation and individuation - preliminary research

    Directory of Open Access Journals (Sweden)

    Gregor Žvelc

    2000-06-01

    Full Text Available Authors introduce a new instrument, which they developed for measuring separation and individuation process and attachment in adolescence and adulthood. The Picture Test of Separation and Individuation (PTSI is a semi–projective test. It consists of various pictures, which represent relationships with significant others. PTSI is divided into three subtests: Relationship with Mother, Relationship with Father and Attachment. In a preliminary research on a sample of college and university students authors studied basic properties of the test. The results of the research indicate that PTSI is consistent with theoretical background, has good sensitivity and is economical. The Picture Test of Separation and Individuation enables quick but complex insight into individual's relationships with significant others as well as into his/her stage of separation and individuation process. Considering satisfying results of pilot study, authors suggest further research for validation of the test.

  4. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  5. Primary care validation of a single-question alcohol screening test.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  6. Screening for Drug Abuse Among College Students: Modification of the Michigan Alcoholism Screening Test

    Science.gov (United States)

    Cannell, M. Barry; Favazza, Armando R.

    1978-01-01

    Modified version of the Michigan Alcoholism Screening Test was anonymously given to 245 college students on two Midwestern university campuses. Cutoff score for suspected drug abuse was set at five points. The percent of students scoring five or more points was 25 and 22 from campuses A and B respectively. (Author)

  7. The triple test as a screening technique for Down syndrome: reliability and relevance

    Directory of Open Access Journals (Sweden)

    Tim Reynolds

    2010-05-01

    Full Text Available Tim ReynoldsClinical Chemistry Department, Queen’s Hospital, Burton-on-Trent, Staffordshire, UKAbstract: The triple test is a second trimester screening test used to identify those pregnant women who should be offered a diagnostic test to identify whether their fetus has an aneuploidy. It was first described in 1988, but has largely been superseded by newer tests either conducted earlier in the first trimester (ie, the combined test, using ultrasound measurement of nuchal translucency,pregnancy-associated plasma protein A, and human chorionic gonadotrophin [hCG] or in the second trimester (ie, the quadruple test, using α-fetoprotein, hCG, uE3, and inhibin. These newer tests have been introduced because they offer greater detection and lower screen positive results thereby enhancing diagnosis rates, while decreasing the risk of iatrogenic harm caused by the invasive testing required when collecting suitable sample tissue. Noninvasive alternatives to the triple test have been identified, but these have not been adopted despite 13 years of development. It is likely, therefore, that the triple test (or variants thereof will continue to be used in routine antenatal care for the foreseeable future.Keywords: pregnancy, screening test, antenatal, Down syndrome

  8. Opportunistic testing versus organized prostate-specific antigen screening: outcome after 18 years in the Göteborg randomized population-based prostate cancer screening trial.

    Science.gov (United States)

    Arnsrud Godtman, Rebecka; Holmberg, Erik; Lilja, Hans; Stranne, Johan; Hugosson, Jonas

    2015-09-01

    It has been shown that organized screening decreases prostate cancer (PC) mortality, but the effect of opportunistic screening is largely unknown. To compare the ability to reduce PC mortality and the risk of overdiagnosis between organized and opportunistic screening. The Göteborg screening study invited 10 000 randomly selected men for prostate-specific antigen (PSA) testing every 2 yr since 1995, with a prostate biopsy recommended for men with PSA ≥2.5 ng/ml. The control group of 10 000 men not invited has been exposed to a previously reported increased rate of opportunistic PSA testing. Both groups were followed until December 31, 2012. Observed cumulative PC incidence and mortality rates in both groups were calculated using the actuarial method. Using historical data from 1990-1994 (pre-PSA era), we calculated expected PC incidence and mortality rates in the absence of any PSA testing. The number needed to invite (NNI) and the number needed to diagnose (NND) were calculated by comparing the expected versus observed incidence and mortality rates. At 18 yr, 1396 men were diagnosed with PC and 79 men died of PC in the screening group, compared to 962 and 122, respectively, in the control group. In the screening group, the observed cumulative PC incidence/mortality was 16%/0.98% compared to expected values of 6.8%/1.7%. The corresponding values for the control group were 11%/1.5% and 6.9%/1.7%. Organized screening was associated with an absolute PC-specific mortality reduction of 0.72% (95% confidence interval [CI] 0.50-0.94%) and relative risk reduction of 42% (95% CI 28-54%). There was an absolute reduction in PC deaths of 0.20% (95% CI -0.06% to 0.47%) and a relative risk reduction of 12% (95% CI -5 to 26%) associated with opportunistic PSA testing. NNI and NND were 139 (95% CI 107-200) and 13 for organized biennial screening and 493 (95% CI 213- -1563) and 23 for opportunistic screening. The extent of opportunistic screening could not be measured

  9. The King-Devick test for sideline concussion screening in collegiate football.

    Science.gov (United States)

    Leong, Danielle F; Balcer, Laura J; Galetta, Steven L; Evans, Greg; Gimre, Matthew; Watt, David

    2015-01-01

    Sports-related concussion has received increasing attention as a result of neurologic sequelae seen among athletes, highlighting the need for a validated, rapid screening tool. The King-Devick (K-D) test requires vision, eye movements, language function and attention in order to perform and has been proposed as a promising tool for assessment of concussion. We investigated the K-D test as a sideline screening tool in a collegiate cohort to determine the effect of concussion. Athletes (n=127, mean age 19.6±1.2 years) from the Wheaton College football and men's and women's basketball teams underwent baseline K-D testing at pre-season physicals for the 2012-2013 season. K-D testing was administered immediately on the sidelines for football players with suspected head injury during regular games and changes compared to baseline were determined. Post-season testing was also performed to compare non-concussed athletes' test performance. Concussed athletes (n=11) displayed sideline K-D scores that were significantly higher (worse) than baseline (36.5±5.6s vs. 31.3±4.5s, pWilcoxon signed-rank test). Post-season testing demonstrated improvement of scores and was consistent with known learning effects (35.1±5.2s vs. 34.4±5.0s, pWilcoxon signed-rank test). Test-retest reliability was analyzed between baseline and post-season administrations of the K-D test resulting in high levels of test-retest reliability (intraclass correlation coefficient (ICC)=0.95 [95% Confidence Interval 0.85-1.05]). The data show worsening of K-D test scores following concussion further supporting utility of the K-D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  10. Results from the Dutch speech-in-noise screening test by telephone

    NARCIS (Netherlands)

    Smits, C.H.M.; Houtgast, T.

    2005-01-01

    OBJECTIVE: The objective of the study was to implement a previously developed automatic speech-in-noise screening test by telephone (Smits, Kapteyn, & Houtgast, 2004), introduce it nationwide as a self-test, and analyze the results. DESIGN: The test was implemented on an interactive voice response

  11. Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons

    Science.gov (United States)

    Maggard, Katie R; Hatwiinda, Sisa; Harris, Jennifer B; Phiri, Winifreda; Krüüner, Annika; Kaunda, Kaunda; Topp, Stephanie M; Kapata, Nathan; Ayles, Helen; Chileshe, Chisela; Henostroza, German

    2015-01-01

    Abstract Objective To improve the Zambia Prisons Service’s implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia’s prisons. Findings In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere. PMID:25883402

  12. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Science.gov (United States)

    2010-07-01

    ... developmental defects should not be used. Healthy virgin animals, not subjected to previous experimental..., except legal holidays. (1) OECD (1995). Reproduction/Developmental Toxicity Screening Test, OECD 421...

  14. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  15. [New visual field testing possibilities (a preliminary report)].

    Science.gov (United States)

    Erichev, V P; Ermolaev, A P; Antonov, A A; Grigoryan, G L; Kosova, D V

    2018-01-01

    There are currently no portable mobile perimeters that allow visual field testing outside ophthalmologist's examination rooms. To develop a mobile perimetry technique based on use of a virtual reality headset (VR). The study involved 26 patients (30 eyes) with II-III stage primary open-angle glaucoma (POAG) with compensated IOP. Perimetry was performed for each patient twice - on Humphrey analyzer (test 30-2, 76 points) and employing similar strategy on a perimeter integrated into VR headset (Total Vision, Russia). Visual field testing was performed with an interval from 1 hour to 3 days. The results were comparatively analyzed. Patients tolerated the examination well. Comparative analysis of preliminary perimetry results obtained with both methods showed high degree of identity, so the results were concluded to be comparable. By visually isolating the wearer, VR headset achieves elimination of distractions and stable light conditions for visual field testing. The headset-perimeter is compact, mobile, easily transportable, can be used in the work of visiting medical teams and for examination at home.

  16. The King–Devick test for sideline concussion screening in collegiate football

    Directory of Open Access Journals (Sweden)

    Danielle F. Leong

    2015-04-01

    Conclusions: The data show worsening of K–D test scores following concussion further supporting utility of the K–D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion.

  17. Evaluation of the localization auditory screening test in children 6-18 months of age.

    Science.gov (United States)

    Tillis, C H; Grimm, W A

    1978-01-01

    The present paper is a report of a project to develop an automated auditory screening test for infants six to 18 months of age. The first year of the project was devoted to developing equipment and test procedures; the second year was concerned with testing the effectiveness of the equipment and procedures on an actual population of six to 18 month old infants. Two-hundred and fifty infants were screened auditorily as part of a county health department child development clinic. The pass/fail results of the screening test were evaluated in terms of physical and developmental examination following the screening and by means of a case review of the child's previous history. The results indicate that the procedure under investigation can be used to differentiate the normal hearing infant from the infant with possible hearing problems. It is shown by the test environment in which this study was conducted that the procedure reported can be successfully incorporated into a public health program, i.e., child development clinics or EPSDT programs.

  18. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  19. [Human papillomavirus testing in cervical cancer screening at a public health service of Santiago, Chile].

    Science.gov (United States)

    Terrazas, Solana; Ibáñez, Carolina; Lagos, Marcela; Poggi, Helena; Brañes, Jorge; Barriga, María Isabel; Cartagena, Jaime; Núñez, Felipe; González, Francisca; Cook, Paz; Van De Wyngard, Vanessa; Ferreccio, Catterina

    2015-01-01

    Molecular techniques for human papillomavirus (HPV) detection have a good performance as screening tests and could be included in cervical cancer early detection programs. We conducted a population-based trial comparing HPV detection and Papanicolaou as primary screening tests, in a public health service in Santiago, Chile. To describe the experience of implementing this new molecular test and present the main results of the study. Women aged 25 to 64 enrolled in three public health centers were invited to participate. In all women, samples were collected for Papanicolaou and HPV DNA testing, and naked-eye visual inspection of the cervix with acetic acid was performed. Women with any positive screening test were referred to the local area hospital for diagnostic confirmation with colposcopy and biopsy of suspicious lesions. Screening results were obtained for 8265 women, of whom 931 (11.3%) were positive to any test. The prevalence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was 1.1%; nine women had invasive cervical cancer. Sensitivities for the detection of CIN2+ were 22.1% (95% confidence interval (CI) 16.4-29.2) for Papanicolaou and 92.7% (95% CI 84.4-96.8) for HPV testing; specificities were 98.9% (95% CI 98.7-99.0) and 92.0% (95% CI 91.4-92.6) respectively. This experience showed that the implementation of a molecular test for cervical cancer screening is not a major challenge in Chile: it was well accepted by both the health team and the participants, and it may improve the effectiveness of the screening program.

  20. [Screening for psychiatric risk factors in a facial trauma patients. Validating a questionnaire].

    Science.gov (United States)

    Foletti, J M; Bruneau, S; Farisse, J; Thiery, G; Chossegros, C; Guyot, L

    2014-12-01

    We recorded similarities between patients managed in the psychiatry department and in the maxillo-facial surgical unit. Our hypothesis was that some psychiatric conditions act as risk factors for facial trauma. We had for aim to test our hypothesis and to validate a simple and efficient questionnaire to identify these psychiatric disorders. Fifty-eight consenting patients with facial trauma, recruited prospectively in the 3 maxillo-facial surgery departments of the Marseille area during 3 months (December 2012-March 2013) completed a self-questionnaire based on the French version of 3 validated screening tests (Self Reported Psychopathy test, Rapid Alcohol Problem Screening test quantity-frequency, and Personal Health Questionnaire). This preliminary study confirmed that psychiatric conditions detected by our questionnaire, namely alcohol abuse and dependence, substance abuse, and depression, were risk factors for facial trauma. Maxillo-facial surgeons are often unaware of psychiatric disorders that may be the cause of facial trauma. The self-screening test we propose allows documenting the psychiatric history of patients and implementing earlier psychiatric care. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    Science.gov (United States)

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  2. Preliminary observations of gate valve flow interruption tests, Phase 2

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.

    1990-01-01

    This paper presents preliminary observations from the US Nuclear Regulatory Commission/Idaho National Engineering Laboratory Flexible Wedge Gate Valve Qualification and Flow Interruption Test Program, Phase 2. The program investigated the ability of selected boiling water reactor (BWR) process line valves to perform their containment isolation function at high energy pipe break conditions and other more normal flow conditions. The fluid and valve operating responses were measured to provide information concerning valve and operator performance at various valve loadings so that the information could be used to assess typical nuclear industry motor operator sizing equations. Six valves were tested, three 6-in. isolation valves representative of those used in reactor water cleanup systems in BWRs and three 10-in. isolation valves representative of those used in BWR high pressure coolant injection (HPCI) steam lines. The concern with these normally open isolation valves is whether they will close in the event of a downstream pipe break outside of containment. The results of this testing will provide part of the technical insights for NRC efforts regarding Generic Issue 87 (GI-87), Failure of the HPCI Steam Line Without Isolation, which includes concerns about the uncertainties in gate valve motor operator sizing and torque switch settings for these BWR containment isolation valves. As of this writing, the Phase 2 test program has just been completed. Preliminary observations made in the field confirmed most of the results from the Phase 1 test program. All six valves closing in high energy water, high energy steam, and high pressure cold water require more force to close than would be calculated using the typical variables in the standard industry motor operator sizing equations

  3. Screening cotton genotypes for seedling drought tolerance

    Directory of Open Access Journals (Sweden)

    Penna Julio C. Viglioni

    1998-01-01

    Full Text Available The objectives of this study were to adapt a screening method previously used to assess seedling drought tolerance in cereals for use in cotton (Gossypium hirsutum L. and to identify tolerant accessions among a wide range of genotypes. Ninety genotypes were screened in seven growth chamber experiments. Fifteen-day-old seedlings were subjected to four 4-day drought cycles, and plant survival was evaluated after each cycle. Three cycles are probably the minimum required in cotton work. Significant differences (at the 0.05 level or lower among entries were obtained in four of the seven experiments. A "confirmation test" with entries previously evaluated as "tolerant" (high survival and "susceptible" (low survival was run. A number of entries duplicated their earlier performance, but others did not, which indicates the need to reevaluate selections. Germplasms considered tolerant included: `IAC-13-1', `IAC-RM4-SM5', `Minas Sertaneja', `Acala 1517E-1' and `4521'. In general, the technique is simple, though time-consuming, with practical value for screening a large number of genotypes. Results from the screening tests generally agreed with field information. The screening procedure is suitable to select tolerant accessions from among a large number of entries in germplasm collections as a preliminary step in breeding for drought tolerance. This research also demonstrated the need to characterize the internal lack of uniformity in growth chambers to allow for adequate designs of experiments.

  4. Uptake of a colorectal cancer screening blood test in people with elevated risk for cancer who cannot or will not complete a faecal occult blood test.

    Science.gov (United States)

    Symonds, Erin L; Cock, Charles; Meng, Rosie; Cole, Stephen R; Fraser, Robert J L; Young, Graeme P

    2017-03-31

    Participation rates in colorectal cancer (CRC) screening programmes using faecal occult blood tests (FOBTs) are low. Nonparticipation is commonly attributed to psychosocial factors, but some medical conditions also prevent screening. These barriers might be partially overcome if a blood test for CRC screening was available. This study determined whether people who had always declined screening by FOBT would participate if offered a blood test. An audit of registrants within a personalized CRC screening programme was undertaken to determine the reasons for regular nonparticipation in FOBT. Consistent nonparticipants (n=240) were randomly selected and invited for CRC screening with a blood test. Demographic characteristics and the reasons for prior FOBT nonparticipation were collected by means of a questionnaire. Nonparticipation in the screening programme could be classified as either behavioural (8.6%), with consistent noncompliance, or due to medical contraindications (8.5%), which included chronic rectal bleeding, being deemed unsuitable by a health professional, and needing personal assistance. Blood test uptake was 25%, with participation in the medical contraindications group greater than that in the behavioural group (43 vs. 12%, Pprocrastination and dislike of the test, but these were not associated with blood test uptake (P>0.05). There is a subgroup of the community who have medical reasons for nonparticipation in CRC screening with FOBT but will participate if offered a blood test. The option of a blood test does not, however, improve uptake in those who admit to behavioural reasons for noncompliance with screening.

  5. Clinical experience from Thailand noninvasive prenatal testing as screening tests for trisomies 21, 18 and 13 in 4736 pregnancies

    DEFF Research Database (Denmark)

    Manotaya, S.; Xu, H.; Uerpairojkit, B.

    2016-01-01

    -risk pregnancies, either with advanced maternal age or positive serum biochemical tests, and 1889 low-risk pregnancies without conventional indications; 99.9% (4732/4736) of the participants with a median maternal age of 35years old received reports, and 1.3% (63/4732) were classified as test positive, including...... testing (NIPT) has enabled efficient and accurate screening for T21, T18 and T13. Various professional societies suggested that NIPT could be considered as a second-tier screening test for women at high risk for aneuploidy. What does this study add? This study reports the performance of NIPT...

  6. Comparison of the automated vision screening test to the Snellen test.

    Science.gov (United States)

    Gofin, R; Falk, M

    1991-03-01

    The comparison of an automatic vision screening machine using the Landolt rings and the usual Snellen Chart was carried out among 123 second grade and 149 fifth grade students in an elementary school in Jerusalem. The sensitivity of the test for a cut-off point of greater than or equal to 6/12 according to the Snellen test was 41.7% (CI = 16.5-71.4) and the specificity was 86.5% (CI 78.1-92.2) for second graders. For fifth graders the values were 50.0% (CI = 20.1-79.9) and 90.6% (CI 83.7-94.8) respectively. Diagnosis by a specialist decreased the number of 'false negatives' and confirmed the pathological cases. The automatic test was well accepted by the children. Though more time is needed for assessment using the automatic test, its advantage is that no professional staff are required.

  7. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening

    NARCIS (Netherlands)

    S.L. Goede (Luuk); A.H.C. Roon (Aafke); J.C.I.Y. Reijerink (Jacqueline); A.J. van Vuuren (Hanneke); I. Lansdorp-Vogelaar (Iris); J.D.F. Habbema (Dik); E.J. Kuipers (Ernst); M.E. van Leerdam (Monique); M. van Ballegooijen (Marjolein)

    2013-01-01

    textabstractObjective The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if

  8. Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dale [Los Alamos National Laboratory; Selby, Neil [AWE Blacknest

    2012-08-14

    Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.

  9. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  10. Preliminary design analysis of the ALT-II limiter for TEXTOR

    International Nuclear Information System (INIS)

    Koski, J.A.; Boyd, R.D.; Kempka, S.M.; Romig, A.D. Jr.; Smith, M.F.; Watson, R.D.; Whitley, J.B.; Conn, R.W.; Grotz, S.P.

    1984-01-01

    Installation of a large toroidal belt pump limiter, Advanced Limiter Test II (ALT-II), on the TEXTOR tokamak at Juelich, FRG is anticipated for early 1986. This paper discusses the preliminary mechanical design and materials considerations undertaken as part of the feasibility study phase for ALT-II. Since the actively cooled limiter blade is the component in direct contact with the plasma edge, and thus subject to the severe plasma environment, most preliminary design efforts have concentrated on analysis of the blade. The screening process which led to the recommended preliminary design consisting of a dispersion strenghthened copper or OFHC copper cover plate over an austenitic stainless steel base plate is discussed. A 1 to 3 mm thick low atomic number coating consisting of a graded plasma-sprayed Silicon Carbide-Aluminium composite is recommended subject to further experiment and evaluation. Thermal-hydraulic and stress analyses of the limiter blade are also discussed. (orig.)

  11. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  12. Elevated phenylalanine on newborn screening: follow-up testing may reveal undiagnosed galactosaemia.

    Science.gov (United States)

    Shakespeare, Lynette; Downing, Melanie; Allen, Joyce; Casbolt, Ann-Marie; Ellin, Sheila; Maloney, Martin; Race, Gillian; Bonham, Jim

    2010-11-01

    Introduction Newborn screening for phenylketonuria (PKU) can reveal other conditions which lead to an increased blood spot phenylalanine (Phe) concentration. We have investigated the proportion of blood spot samples that gave a positive screen due to clinically significant conditions other than PKU, compared the positive predictive value (PPV) of our referral Phe cut-off with that recommended by the UK Newborn Screening Programme Centre (UKNSPC) (>210 and >240 μmol/L, respectively) and evaluated the effectiveness of reflex testing for galactosaemia using a lower blood spot Phe cut-off concentration of 130 μmol/L. All blood spot samples that screened positive, for an increased Phe concentration, between April 2001 and March 2008, were identified from the records of the Sheffield Newborn Screening Laboratory and the diagnoses noted. In addition, all cases of galactosaemia detected in or notified to our screening laboratory within this time were also examined and the screened Phe concentrations compared. Out of 438,674 babies who were screened, 67 had Phe concentration >210 μmol/L (15 per 100,000). Of these, 40 had PKU or persistent hyperphenylalaninaemia with a Phe concentration identified by screening between 270 and 2350 μmol/L. A further 11 were diagnosed with another clinically significant disorder: galactosaemia (n = 8), biopterin defects (n = 2), tyrosinaemia Type 1 (n = 1). In addition, 16 had transient elevations in Phe. In total, nine cases of galactosaemia were identified, of whom, three had Phe concentrations 240 μmol/L) will not affect the detection rate of classical PKU, but will improve the PPV from 76% to 80%. The use of a lower cut-off (130 μmol/L) for reflex galactosaemia testing enables the timely identification of asymptomatic cases that benefit particularly from early treatment, without prompting any unnecessary clinical referrals or delaying any referrals. This intervention may reduce mortality in this vulnerable group.

  13. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Preliminary data evaluation for thermal insulation characterization testing

    International Nuclear Information System (INIS)

    DeClue, J.F.; Moses, S.D.; Tollefson, D.A.

    1991-01-01

    The purpose of Thermal Insulation Characterization Testing is to provide physical data to support certain assumptions and calculational techniques used in the criticality safety calculations in Section 6 of the Safety Analysis Reports for Packaging (SARPs) for drum-type packaging for Department of Energy's (DOE) Oak Ridge Y-12 Plant, managed by Martin Marietta Energy Systems, Inc. Results of preliminary data evaluation regarding the fire-test condition reveal that realistic weight loss consideration and residual material characterization in developing calculational models for the hypothetical accident condition is necessary in order to prevent placement of unduly conservative restrictions on shipping requirements as a result of overly conservative modeling. This is particularly important for fast systems. Determination of the geometric arrangement of residual material is of secondary importance. Both the methodology used to determine the minimum thermal insulation mass remaining after the fire test and the treatment of the thermal insulation in the criticality safety calculational models requires additional evaluation. Specific testing to be conducted will provide experimental data with which to validate the mass estimates and calculational modeling techniques for extrapolation to generic drum-type containers

  15. A new motor screening assessment for children at risk for motor disorders: construct validity

    Directory of Open Access Journals (Sweden)

    Paola Matiko Martins Okuda

    Full Text Available ABSTRACT Objective: To develop a motor screening assessment and provide preliminary evidence of its psychometric properties. Methods: A sample of 365 elementary school students was assessed, with structural equation modeling applied to obtain evidence of the adequacy of the factor structure of the motor screening assessment. As well, differential item functioning was used to evaluate whether various identifiable subgroups of children (i.e., sex and grade perform particular tasks differently. Results: Overall, girls obtained higher scores than boys while, for both sexes, the assessment scores increased with age. Furthermore, differential item function analysis revealed that the precision of the test was highest for those with moderate to low motor performance, suggesting that this tool would be appropriate for identifying individuals with movement difficulties. Conclusion: Although further tests of its psychometric properties are required, the motor screening assessment appears to be a reliable, valid, and quickly-administered tool for screening children's movements.

  16. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  17. Hydraulically driven control rod concept for integral reactors: fluid dynamic simulation and preliminary test

    International Nuclear Information System (INIS)

    Ricotti, M.E.; Cammi, A.; Lombardi, C.; Passoni, M.; Rizzo, C.; Carelli, M.; Colombo, E.

    2003-01-01

    The paper deals with the preliminary study of the Hydraulically Driven Control Rod concept, tailored for PWR control rods (spider type) with hydraulic drive mechanism completely immersed in the primary water. A specific solution suitable for advanced versions of the IRIS integral reactor is under investigation. The configuration of the Hydraulic Control Rod device, made up by an external movable piston and an internal fixed cylinder, is described. After a brief description of the whole control system, particular attention is devoted to the Control Rod characterization via Computational Fluid Dynamics (CFD) analysis. The investigation of the system behavior, including dynamic equilibrium and stability properties, has been carried out. Finally, preliminary tests were performed in a low pressure, low temperature, reduced length experimental facility. The results are compared with the dynamic control model and CFD simulation model, showing good agreement between simulations and experimental data. During these preliminary tests, the control system performs correctly, allowing stable dynamic equilibrium positions for the Control Rod and stable behavior during withdrawal and insertion steps. (author)

  18. Determinants of participation in colorectal cancer screening with faecal occult blood testing

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Brasso, Klaus; Lynge, Elsebeth

    2009-01-01

    BACKGROUND: Colorectal cancer is one of the most common cancers in men and women. Participation rates in faecal occult blood testing (FOBT) screening activities are, however, relatively low. In terms of lowering the colorectal cancer mortality, high participation rates are essential, and therefore......, but determinants varied across countries and test settings. There was no systematic variation in participation across age groups. CONCLUSION: The participation pattern depends in part on local circumstances, which makes it difficult to point to a general strategy for increasing the uptake in FOBT screening...

  19. Preliminary Calculations of Bypass Flow Distribution in a Multi-Block Air Test

    International Nuclear Information System (INIS)

    Kim, Min Hwan; Tak, Nam Il

    2011-01-01

    The development of a methodology for the bypass flow assessment in a prismatic VHTR (Very High Temperature Reactor) core has been conducted at KAERI. A preliminary estimation of variation of local bypass flow gap size between graphite blocks in the NHDD core were carried out. With the predicted gap sizes, their influence on the bypass flow distribution and the core hot spot was assessed. Due to the complexity of gap distributions, a system thermo-fluid analysis code is suggested as a tool for the core thermo-fluid analysis, the model and correlations of which should be validated. In order to generate data for validating the bypass flow analysis model, an experimental facility for a multi-block air test was constructed at Seoul National University (SNU). This study is focused on the preliminary evaluation of flow distribution in the test section to understand how the flow is distributed and to help the selection of experimental case. A commercial CFD code, ANSYS CFX is used for the analyses

  20. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Validation of a telephone screening test for Alzheimer's disease.

    Science.gov (United States)

    Camozzato, Ana Luiza; Kochhann, Renata; Godinho, Claudia; Costa, Amanda; Chaves, Marcia L

    2011-03-01

    Financial constraints, mobility issues, medical conditions, crime in local areas can make cognitive assessment difficult for elders and telephone interviews can be a good alternative. This study was carried out to evaluate the reliability, validity and clinical utility of a Brazilian telephone version of the Mini Mental State Examination (Braztel-MMSE) in a community sample of healthy elderly participants and AD patients. The MMSE and the Braztel-MMSE were applied to 66 AD patients and 67 healthy elderly participants. The test-retest reliability was strong and significant (r = .92, p = .01), and the correlation between the Braztel-MMSE and the MMSE were significant (p = .01) and strong (r = .92). The general screening ability of the Braztel-MMSE was high (AUC = 0.982; CI95% = 0.964-1.001). This telephone version can therefore be used as a screening measure for dementia in older adults that need neuropsychological screening and cannot present for an evaluation.

  2. Preliminary investigation on determination of radionuclide distribution in field tracing test site

    International Nuclear Information System (INIS)

    Tanaka, Tadao; Mukai, Masayuki; Takebe, Shinichi; Guo Zede; Li Shushen; Kamiyama, Hideo.

    1993-12-01

    Field tracing tests for radionuclide migration have been conducted by using 3 H, 60 Co, 85 Sr and 134 Cs, in the natural unsaturated loess zone at field test site of China Institute for Radiation Protection. It is necessary to obtain confidable distribution data of the radionuclides in the test site, in order to evaluate exactly the migration behavior of the radionuclides in situ. An available method to determine the distribution was proposed on the basis of preliminary discussing results on sampling method of soils from the test site and analytical method of radioactivity in the soils. (author)

  3. Comparison of accuracy measures of two screening tests for gestational diabetes mellitus

    NARCIS (Netherlands)

    van Leeuwen, Marsha; Zweers, Egbert J. K.; Opmeer, Brent C.; van Ballegooie, Evert; ter Brugge, Henk G.; de Valk, Harold W.; Mol, Ben W. J.; Visser, Gerard H. A.

    2007-01-01

    OBJECTIVE: To compare the accuracy measures of the random glucose test and the 50-g glucose challenge test as screening tests for gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS: In this prospective cohort study, pregnant women without preexisting diabetes in two perinatal centers

  4. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    Science.gov (United States)

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  5. Cost-effectiveness analysis of the optimal threshold of an automated immunochemical test for colorectal cancer screening: performances of immunochemical colorectal cancer screening.

    Science.gov (United States)

    Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy

    2010-01-01

    Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.

  6. Embryotoxicity of Mirtazapine: a study using Chick Embryotoxicity Screening Test

    Czech Academy of Sciences Publication Activity Database

    Maňáková, E.; Hubičková, L.; Košťálová, J.; Zemanová, Zdeňka

    2010-01-01

    Roč. 31, Suppl.2 (2010), s. 8-10 ISSN 0172-780X Institutional research plan: CEZ:AV0Z50110509 Keywords : embryo toxicity * screening test * mirtazapine Subject RIV: EA - Cell Biology Impact factor: 1.621, year: 2010

  7. Expanded newborn screening by mass spectrometry: New tests, future perspectives.

    Science.gov (United States)

    Ombrone, Daniela; Giocaliere, Elisa; Forni, Giulia; Malvagia, Sabrina; la Marca, Giancarlo

    2016-01-01

    Tandem mass spectrometry (MS/MS) has become a leading technology used in clinical chemistry and has shown to be particularly sensitive and specific when used in newborn screening (NBS) tests. The success of tandem mass spectrometry is due to important advances in hardware, software and clinical applications during the last 25 years. MS/MS permits a very rapid measurement of many metabolites in different biological specimens by using filter paper spots or directly on biological fluids. Its use in NBS give us the chance to identify possible treatable metabolic disorders even when asymptomatic and the benefits gained by this type of screening is now recognized worldwide. Today the use of MS/MS for second-tier tests and confirmatory testing is promising especially in the early detection of new disorders such as some lysosomal storage disorders, ADA and PNP SCIDs, X-adrenoleucodistrophy (X-ALD), Wilson disease, guanidinoacetate methyltransferase deficiency (GAMT), and Duchenne muscular dystrophy. The new challenge for the future will be reducing the false positive rate by using second-tier tests, avoiding false negative results by using new specific biomarkers and introducing new treatable disorders in NBS programs. © 2015 Wiley Periodicals, Inc.

  8. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  9. Validation of the Hwalek-Sengstock Elder Abuse Screening Test.

    Science.gov (United States)

    Neale, Anne Victoria; And Others

    Elder abuse is recognized as an under-detected and under-reported social problem. Difficulties in detecting elder abuse are compounded by the lack of a standardized, psychometrically valid instrument for case finding. The development of the Hwalek-Sengstock Elder Abuse Screening Test (H-S/EAST) followed a larger effort to identify indicators and…

  10. Spectrum of patients with hypermethioninemia based on neonatal screening tests over 14 years

    Directory of Open Access Journals (Sweden)

    Se Jung Oh

    2010-03-01

    Full Text Available Purpose : The neonatal screening test for homocystinuria primarily measures methionine by using a dried blood specimen. We investigated the incidence and clinical manifestations of homocystinuria, isolated hypermethioninemia, and transient hypermethioninemia among patients with hypermethioninemia on a neonatal screening test. Methods : We performed a retrospective study of 58 patients transferred to Shoonchunhyang Hospital because of hypermethioninemia on a neonatal screening test between January 1996 and August 2009. We analyzed the level of amino acid from plasma and urine, as well as blood homocysteine. Results : Almost half of the 58 patients were identified as normal. Whereas only 3 (5.1% patients were identified as having homocystinuria, about 20.7% (12 cases of the patients had isolated hypermethioninemia. The ages of these two groups at initial detection of hypermethioninemia on plasma amino acid analysis were 50.0¡?#?2.5; days and 34.9¡?#?3.5; days, respectively. Both groups were put on diets, and they showed a normal developmental course as a result of early diagnosis and treatment. Conclusion : Hypermethioninemia without homocystinuria, referred to as isolated hypermethioninemia, was also detected. Thus, the impact of hypermethioninemia on a neonatal screening test should be carefully evaluated through analysis of amino acid levels from blood and urine, and we need to detect and treat an early stage of isolated hypermethioninemia as well as homocystinuria.

  11. The Clock Drawing Test A review of its accuracy in screening for dementia

    Directory of Open Access Journals (Sweden)

    Ivan Aprahamian

    Full Text Available Abstract The Clock Drawing Test (CDT is a simple neuropsychometric instrument that can be easily applied to assess several cognitive functions. Over the past 20 years, the CDT has aroused considerable interest in its role for the early screening of cognitive impairment, especially in dementia. Although the CDT is considered an accurate test for dementia screening, recent studies including comparisons with structured batteries such as the CAMCOG have shown mixed results. Objectives: To investigate the importance of the CDT compared to other commonly used tests, in the diagnosis of dementia in the elderly; (2 to evaluate the reliability and correlation between available CDT scoring scales from recent studies. Methods: A systematic search in the literature was conducted in September 2008 for studies comparing CDT scoring systems and comparing the CDT with neuropsychiatric batteries. Results: Twelve studies were selected for analyses. Seven of these studies compared CDT scoring scales while five compared the CDT against the CAMCOG and the MMSE. Eight studies found good correlation and reliability between the scales and the other tests. Conclusion: Despite the mixed results in these studies, the CDT appears to be a good screening test for dementia.

  12. Imaging evaluation of infants with neuroblastoma detected by VMA screening spot test

    International Nuclear Information System (INIS)

    Fujioka, M.; Saiki, N.; Aihara, T.; Yamamoto, K.

    1988-01-01

    In the Saitama Prefecture in Japan, VMA (vanillyl manderic acid) screening spot test for detection of neuroblastoma has been performed in 173,046 infants in the years 1981-1986 and 15 infants were found to have neuroblastoma. Two infants had mediastinal tumors and the remainder, 13, had intraabdominal tumors. Only 7 infants had palpable masses. Although CT was documented to be the best imaging procedure to provide sufficient information for treatment, conventional radiographic examinations of the chest and abdomen, and abdominal ultrasonography were able, as initial imaging procedures, to detect reasonably small neuroblastomas in infants with a positive VMA screening test. (orig.)

  13. Preliminary Phytochemical and Biological Screening of Cyclamen coum a Member of Palestinian Flora

    Directory of Open Access Journals (Sweden)

    Nidal Amin Jaradat, Motasem Al-Masri, Fatmeh Hussen, Abed Naser Zaid, Iyad Ali, Ala Tammam, Doaa Mostafa Odeh, Omaima Hussein Shakarneh, Areej Rajabi

    2017-09-01

    Full Text Available Background: Since ancient times, the treatment of various diseases has relied on medicinal plants. The replacement of chemically synthesized drugs with natural medications gave the later advantageous due to their safety for humans. This study aimed to screen and to evaluate preliminarily phytoconstituents, total contents of flavonoids, tannins, and phenols also to evaluate the antibacterial and antioxidant activities of Cyclamen coum aerial parts methanol extract. Methods: Screening of phytoconstituents, total flavonoids, tannins and phenols contents, as well as antioxidant properties, were investigated for the Cyclamen coum aerial parts by using standard phytochemical and analytical methods. Evaluation of antibacterial activity of the plant methanolic extract was performed by using broth microdilution method. American Type Culture Collections of Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Methicillin-Resistant Staphylococcus aureus (MRSA were utilized to evaluate antibacterial activity. Results: Preliminary phytochemical qualitative analysis of the plant methanolic extract showed that the plant aerial parts contained amino acids, reducing sugar, carbohydrate, tannin, flavonoid, phenol, saponin, cardiac glycoside, and steroids. Total flavonoids, phenols, and tannins in plant methanolic extract were 60.88 mg QUE/g, 32.7 mg GAE/g and 11.7 mg CAE/g, respectively. Meanwhile, the antioxidant activity was estimated to be 31 µg/mL and has very weak antibacterial activity on the studied pathogens. Conclusion: In the present study, evaluation of total phenolic, tannins and flavonoid content from the aerial parts of C. coum can be an antioxidant naturally potent source. The results of in-vitro antibacterial studies showed that the studied plant has very weak antibacterial activity. In addition, the presence of antioxidant compounds in C. coum makes it a good candidate for manufacturing dietary supplements and food preservatives

  14. TPX: Contractor preliminary design review. Volume 5, Manufacturing R&D

    Energy Technology Data Exchange (ETDEWEB)

    Roach, J.F.; Urban, W.M.; Hartman, D. [Everson Electric Co., Bekthlehem, PA (United States)

    1995-08-04

    TPX Insulation & Impregnation R&D test results are reported for 1x2 samples designed for screening candidate conduit insulation systems for TPX PF and TF coils. The epoxy/glass insulation system and three proposed alternate insulation systems employing Kapton, was evaluated in as received sample condition and after 10 thermal cycles in liquid nitrogen. Two DGBA impregnation systems, Shell 826 and CTD101K were investigated. Square incoloy 908 and 316 LN stainless hollow conduits were used for 1x2 sample fabrication. Capacitance, dielectric loss, and insulation resistance dielectric characteristics were measured for all samples. Partial discharge performance was measured for samples either in air, under silicon oil, or under liquid nitrogen up to 10kVrms at 60 Hz. Hipot screening was performed at 10 kVdc. The samples were cross sectioned and evaluated for impregnation quality. The implications of the test results on the TPX preliminary design decision are discussed.

  15. Results of the Preliminary Test in the 1/4-Scale RCCS of the PMR200 VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Hwan; Bae, Yoon-Yeong; Hong, Sung-Deok; Kim, Chan-Soo; Cho, Bong-Hyun; Kim, Min-Hwan [Nuclear Hydrogen Reactor Technology Development Dep., Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The Reactor Cavity Cooling System (RCCS) is a key ex-vessel passive safety system that will ensure the safety of the PMR200, and its performance needs to be verified. For the difficulty of the full-scale test, a 1/4-scale RCCS facility, NACEF (Natural Cooling Experimental Facility), has been constructed at KAERI, and a shakedown test has been performed. A brief design and the preliminary test results of this facility are described. A 1/4-scale RCCS mockup of PMR200, NACEF, was constructed and tested preliminarily. The functioning of the facility worked quite well. Moreover, the preliminary test results show a fairly good agreement with past work except for the conductive heat transfer region in the riser bottom. After a remedy such as the installation of more precise flow meters and a more improved insulation, the test facility is likely to work well.

  16. Awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests in Spain.

    Science.gov (United States)

    Carrasco-Garrido, Pilar; Hernandez-Barrera, Valentın; Lopez de Andres, Ana; Jimenez-Trujillo, Isabel; Gallardo Pino, Carmen; Jimenez-Garcıa, Rodrigo

    2014-04-01

    We aim to describe levels of awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests and to analyze the association to socio-demographic and health-related variables. Population-based cross-sectional study conducted using a home-based personal interview survey on a nationwide representative sample (n = 7938) of population aged ≥18 years (Oncobarometro Survey). Awareness was assessed by asking participants: Now I am going to mention several medical tests for cancer detection, please tell me if you already know about them or if this is the first time you have heard of them? The tests mentioned were faecal occult blood test (FOBT), mammography, Pap smear and prostate-specific antigen (PSA). Cancer screening uptake was assessed by asking participants whether they had received tests within the previous 2 years. Awareness rates of 38.55% for FOBT, 95.03% for mammography, 70.84% for Pap smears and 54.72% for PSA were found. Uptake mammography was 74.46%, Pap smears 65.57%, PSA 35.19% and FOBT 9.40%. Factors such as immigration status, lower educational level or income and not suffering from chronic conditions are negative predictors for uptake. Awareness and uptake results showed acceptable figures for mammography, moderate for Pap smears and unacceptably low for FOBT. Inequalities exist in uptake of cancer screening. It is necessary to develop public health educational programmes, especially for the vulnerable populations, aiming to inform and motivate them to use screening services on a regular basis. Our data suggest that although PSA is not recommended, this opportunistic screening is frequently used in Spain.

  17. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison.

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G Prasad; Tiwari, Sarvada C; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated.

  18. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122

  19. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test.

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-10-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler Preschool-and-Primary-Scale-of-Intelligence-WPPSI). Group differences were analyzed using t tests, as well as direct and stepwise discriminant analyses. The predictive value of the WPPSI with respect to TT performance was analyzed using regression analyses. SLI-children performed significantly worse on both TT and WPPSI ([Formula: see text]). The TT alone yielded an overall classification rate of 79%, the TT and the WPPSI together yielded an overall classification rate of 80%. TT performance was significantly predicted by verbal intelligence in SLI-children and nonverbal intelligence in controls whilst WPPSI subtest arithmetic was predictive in both groups. Without further research, the Token Test cannot be seen as a valid and sufficient tool for the screening of SLI in preschool children but rather as a tool for the assessment of more general intellectual capacities. SLI-children at this age already show impairments typically associated with SLI which indicates the necessity of early developmental support or training. Token Test performance is possibly an indicator for a more general developmental factor rather than an exclusive indicator for language difficulties.

  20. [Mokken scaling of the Cognitive Screening Test].

    Science.gov (United States)

    Diesfeldt, H F A

    2009-10-01

    The Cognitive Screening Test (CST) is a twenty-item orientation questionnaire in Dutch, that is commonly used to evaluate cognitive impairment. This study applied Mokken Scale Analysis, a non-parametric set of techniques derived from item response theory (IRT), to CST-data of 466 consecutive participants in psychogeriatric day care. The full item set and the standard short version of fourteen items both met the assumptions of the monotone homogeneity model, with scalability coefficient H = 0.39, which is considered weak. In order to select items that would fulfil the assumption of invariant item ordering or the double monotonicity model, the subjects were randomly partitioned into a training set (50% of the sample) and a test set (the remaining half). By means of an automated item selection eleven items were found to measure one latent trait, with H = 0.67 and item H coefficients larger than 0.51. Cross-validation of the item analysis in the remaining half of the subjects gave comparable values (H = 0.66; item H coefficients larger than 0.56). The selected items involve year, place of residence, birth date, the monarch's and prime minister's names, and their predecessors. Applying optimal discriminant analysis (ODA) it was found that the full set of twenty CST items performed best in distinguishing two predefined groups of patients of lower or higher cognitive ability, as established by an independent criterion derived from the Amsterdam Dementia Screening Test. The chance corrected predictive value or prognostic utility was 47.5% for the full item set, 45.2% for the fourteen items of the standard short version of the CST, and 46.1% for the homogeneous, unidimensional set of selected eleven items. The results of the item analysis support the application of the CST in cognitive assessment, and revealed a more reliable 'short' version of the CST than the standard short version (CST14).

  1. Preliminary environmental analysis of a geopressured-geothermal test well in Brazoria County, Texas

    Energy Technology Data Exchange (ETDEWEB)

    White, W.A.; McGraw, M.; Gustavson, T.C.; Meriwether, J.

    1977-11-16

    Preliminary environmental data, including current land use, substrate lithology, soils, natural hazards, water resources, biological assemblages, meteorological data, and regulatory considerations have been collected and analyzed for approximately 150 km/sup 2/ of land near Chocolate Bayou, Brazoria County, Texas, in which a geopressured-geothermal test well is to be drilled in the fall of 1977. The study was designed to establish an environmental data base and to determine, within spatial constraints set by subsurface reservoir conditions, environmentally suitable sites for the proposed well. Preliminary analyses of data revealed the eed for focusing on the following areas: potential for subsidence and fault activation, susceptibility of test well and support facilities to fresh- and salt-water flooding, possible effects of produced saline waters on biological assemblages and groundwaer resources, distribution of expansive soils, and effect of drilling and associated support activities on known archeological-cultural resources.

  2. Rapid detection of methicillin resistance in Staphylococcus aureus isolates by the MRSA-screen latex agglutination test

    NARCIS (Netherlands)

    W.B. van Leeuwen (Willem); C. van Pelt (Cindy); A. Luijendijk (Ad); H.A. Verbrugh (Henri); W.H.F. Goessens (Wil)

    1999-01-01

    textabstractThe slide agglutination test MRSA-Screen (Denka Seiken Co., Niigata, Japan) was compared with the mecA PCR ("gold standard") for the detection of methicillin resistance in Staphylococcus aureus. The MRSA-Screen test detected the penicillin-binding protein 2a

  3. Attitudes towards colorectal cancer (CRC) and CRC screening tests among elderly Malay patients.

    Science.gov (United States)

    Al-Naggar, Redhwan A; Al-Kubaisy, Waqar; Yap, Bee W; Bobryshev, Yuri V; Osman, Muhamed T

    2015-01-01

    Colorectal cancer (CRC) is the third most common malignancy in Malaysia, where data are limited regarding knowledge and barriers in regard to CRC and screening tests. The aim of the study was to assess these parameters among Malaysians. The questionnaires were distributed in the Umra Private Hospital in Selangor. The questionnaire had four parts and covered social-demographic questions, respondent knowledge about CRC and colorectal tests, attitude towards CRC and respondentaction regarding CRC. More than half of Malay participants (total n=187) were female (57.2%) and 36.9% of them were working as professionals. The majority of the participants (93.6%) never had a CRC screening test. The study found that only 10.2% of the study participants did not consider that their chances of getting CRC were high. A high percentage of the participants (43.3%) believed that they would have good chance of survival if the cancer would be found early. About one third of the respondents did not want to do screening because of fear of cancer, and concerns of embarrassment during the procedure adversely affected attitude to CRC screening as well. Age, gender, income, family history of CRC, vegetable intake and physical activity were found to be significant determinants of knowledge on CRC. The major barriers identified towards CRC screening identified in our study were fear of pain and embarrassment. The findings have implications for understanding of similarities and differences in attitude to CRC amongst elderly patients in other cultural/ geographic regions.

  4. Test description and preliminary pitot-pressure surveys for Langley Test Technique Demonstrator at Mach 6

    Science.gov (United States)

    Everhart, Joel L.; Ashby, George C., Jr.; Monta, William J.

    1992-01-01

    A propulsion/airframe integration experiment conducted in the NASA Langley 20-Inch Mach 6 Tunnel using a 16.8-in.-long version of the Langley Test Technique Demonstrator configuration with simulated scramjet propulsion is described. Schlieren and vapor screen visualization of the nozzle flow field is presented and correlated with pitot-pressure flow-field surveys. The data were obtained at nominal free-stream conditions of Re = 2.8 x 10 exp 6 and a nominal engine total pressure of 100 psia. It is concluded that pitot-pressure surveys coupled to schlieren and vapor-screen photographs, and oil flows have revealed flow features including vortices, free shear layers, and shock waves occurring in the model flow field.

  5. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review

    DEFF Research Database (Denmark)

    Frederiksen, Maria Eiholm; Lynge, E; Rebolj, M

    2012-01-01

    Please cite this paper as: Frederiksen M, Lynge E, Rebolj M. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review. BJOG 2011; DOI: 10.1111/j.1471-0528.2011.03130.x. Background If human papillomavirus (HPV) testing will replace...... cytology in primary cervical screening, the frequency of low-grade abnormal screening tests will double. Several available alternatives for the follow-up of low-grade abnormal screening tests have similar outcomes. In this situation, women's preferences have been proposed as a guide for management....... Selection criteria Studies asking women to state a preference between active follow-up and observation for the management of low-grade abnormalities on screening cytology or HPV tests. Data collection and analysis Information on study design, participants and outcomes was retrieved using a prespecified form...

  6. A user-operated test of suprathreshold acuity in noise for adult hearing screening: The SUN (Speech Understanding in Noise) test.

    Science.gov (United States)

    Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando

    2014-09-01

    A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  8. Test for Nonlinear Input Output Relations in SISO Systems by Preliminary Data Analysis

    DEFF Research Database (Denmark)

    Knudsen, Torben

    2000-01-01

    This paper discusses and develops preliminary statistical tests for detecting nonlinearities in the deterministic part of SISO systems with noise. The most referenced method is unreliable for common noise processes as e.g.\\ colored. Therefore two new methods based on superposition and sinus input...

  9. Preliminary engineering specifications for a test demonstration multilayer protective barrier cover system

    International Nuclear Information System (INIS)

    Phillips, S.J.; Gilbert, T.W.; Adams, M.R.

    1985-03-01

    This report presents preliminary engineering specifications for a test protective barrier cover system and support radiohydrology facility to be constructed at the Hanford Protective Barrier Test Facility (PBTF). Construction of this test barrier and related radiohydrology facility is part of a continuing effort to provide construction experience and performance evaluation of alternative barrier designs used for long-term isolation of disposed radioactive waste materials. Design specifications given in this report are tentative, based on interim engineering and computer simulation design efforts. Final definitive design specifications and engineering prints will be produced in FY 1986. 6 refs., 10 figs., 1 tab

  10. Simple test guidelines for screening oilspill sorbents for toxicity

    International Nuclear Information System (INIS)

    Blenkinsopp, S.A.; Sergy, G.; Doe, K.; Jackman, P.; Huybers, A.

    1998-01-01

    Environment Canada's Emergencies Science Division has established a program to develop a standard test method suitable for evaluating the toxicity of common sorbent materials. Sorbents are used to absorb or adsorb spilled oil and other hazardous materials. They vary widely in composition and packaging. They are often treated with oleophilic and hydrophobic compounds to improve performance and have been used in large quantities during oil spills. Until now, their potential toxicity has never been considered. Three tests have been evaluated to determine how appropriate they are in screening the toxicity of sorbents. Seven toxicity test recommendations for sorbents were presented. 7 refs., 3 tabs., 2 figs

  11. Preliminary site design for the SP-100 ground engineering test

    International Nuclear Information System (INIS)

    Cox, C.M.; Miller, W.C.; Mahaffey, M.K.

    1986-04-01

    In November, 1985, Hanford was selected by the Department of Energy (DOE) as the preferred site for a full-scale test of the integrated nuclear subsystem for SP-100. The Hanford Engineering Development Laboratory, operated by Westinghouse Hanford Company, was assigned as the lead contractor for the Test Site. The nuclear subsystem, which includes the reactor and its primary heat transport system, will be provided by the System Developer, another contractor to be selected by DOE in late FY-1986. In addition to reactor operations, test site responsibilities include preparation of the facility plus design, procurement and installation of a vacuum chamber to house the reactor, a secondary heat transport system to dispose of the reactor heat, a facility control system, and postirradiation examination. At the conclusion of the test program, waste disposal and facility decommissioning are required. The test site must also prepare appropriate environmental and safety evaluations. This paper summarizes the preliminary design requirements, the status of design, and plans to achieve full power operation of the test reactor in September, 1990

  12. Jet-Surface Interaction: High Aspect Ratio Nozzle Test, Nozzle Design and Preliminary Data

    Science.gov (United States)

    Brown, Clifford; Dippold, Vance

    2015-01-01

    The Jet-Surface Interaction High Aspect Ratio (JSI-HAR) nozzle test is part of an ongoing effort to measure and predict the noise created when an aircraft engine exhausts close to an airframe surface. The JSI-HAR test is focused on parameters derived from the Turbo-electric Distributed Propulsion (TeDP) concept aircraft which include a high-aspect ratio mailslot exhaust nozzle, internal septa, and an aft deck. The size and mass flow rate limits of the test rig also limited the test nozzle to a 16:1 aspect ratio, half the approximately 32:1 on the TeDP concept. Also, unlike the aircraft, the test nozzle must transition from a single round duct on the High Flow Jet Exit Rig, located in the AeroAcoustic Propulsion Laboratory at the NASA Glenn Research Center, to the rectangular shape at the nozzle exit. A parametric nozzle design method was developed to design three low noise round-to-rectangular transitions, with 8:1, 12:1, and 16: aspect ratios, that minimizes flow separations and shocks while providing a flat flow profile at the nozzle exit. These designs validated using the WIND-US CFD code. A preliminary analysis of the test data shows that the actual flow profile is close to that predicted and that the noise results appear consistent with data from previous, smaller scale, tests. The JSI-HAR test is ongoing through October 2015. The results shown in the presentation are intended to provide an overview of the test and a first look at the preliminary results.

  13. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  14. Reasons for never and intermittent completion of colorectal cancer screening after receiving multiple rounds of mailed fecal tests.

    Science.gov (United States)

    Green, Beverly B; BlueSpruce, June; Tuzzio, Leah; Vernon, Sally W; Aubree Shay, L; Catz, Sheryl L

    2017-05-30

    Long-term adherence to colorectal cancer (CRC) screening is particularly important for fecal testing. Some U.S. studies report that only 25% of individuals repeat fecal testing annually. The purpose of this qualitative study was to identify barriers and facilitators reported by patients with suboptimal screening adherence to refine interventions for starting ongoing adherence to CRC screening. We also explored whether participants, particularly never screeners, would be willing to do a CRC screening blood test. Forty-one patients who previously enrolled in the Systems of Support to Increase CRC Screening (SOS) trial were interviewed 4-5 years later. Participants were purposively selected to include men and women with diverse race/ethnicities who had either been inconsistent screeners or had never screened during the first three years of SOS despite receiving at least two rounds of mailed fecal tests. Two interviewers conducted 30-min telephone interviews using a semi-structured interview guide. An iterative thematic analysis approach was used. Themes related to screening barriers were more pervasive among never screeners including: (1) Avoidance (inattention, procrastination) (2) Concerns about handling stool; (3) Health concerns; (4) Fear of a cancer diagnosis or positive test results. Themes related to screening facilitators were more often mentioned by participants who screened at least once including: (1) Use of a simpler 1-sample fecal test; (2) Convenience of mailings and doing the test at home; (3) Salience of prevention, especially as one got older; and (4) Influence of recommendations from providers, family and friends. Participants had diverse preferences for the number (3 on average) and types (phone, mail, text) of screening reminders. Some participants did not prefer e-mail links to the patient shared electronic health record because of difficulties remembering their password. It was acceptable for a nurse or medical assistant not from their clinic to

  15. Application of direct agglutination test (DAT) and fast agglutination screening test (FAST) for sero-diagnosis of visceral leishmaniasis in endemic area of Minas Gerais, Brazil

    NARCIS (Netherlands)

    Silva, Eduardo S.; Schoone, Gerard J.; Gontijo, Celia M. F.; Brazil, Reginaldo P.; Pacheco, Raquel S.; Schallig, Henk D. F. H.

    2005-01-01

    The direct agglutination test (DAT) has proved to be a very important sero-diagnostic tool combining high levels of intrinsic validity and ease of performance. Otherwise, fast agglutination screening test (FAST) utilises only one serum dilution making the test very suitable for the screening of

  16. Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.

    Science.gov (United States)

    Samuelson, Frank; Abbey, Craig

    2016-11-01

    Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.

  17. Screening for cervical cancer among HIV-positive and HIV-negative women in Cameroon using simultaneous co-testing with careHPV DNA testing and visual inspection enhanced by digital cervicography: Findings of initial screening and one-year follow-up.

    Science.gov (United States)

    Cholli, Preetam; Bradford, Leslie; Manga, Simon; Nulah, Kathleen; Kiyang, Edith; Manjuh, Florence; DeGregorio, Geneva; Ogembo, Rebecca K; Orock, Enow; Liu, Yuxin; Wamai, Richard G; Sheldon, Lisa Kennedy; Gona, Philimon N; Sando, Zacharie; Welty, Thomas; Welty, Edith; Ogembo, Javier Gordon

    2018-01-01

    The World Health Organization (WHO)'s cervical cancer screening guidelines for limited-resource settings recommend sequential screening followed by same-day treatment under a "screen-and-treat" approach. We aimed to (1) assess feasibility and clinical outcomes of screening HIV-positive and HIV-negative Cameroonian women by pairing visual inspection with acetic acid and Lugol's iodine enhanced by digital cervicography (VIA/VILI-DC) with careHPV, a high-risk human papillomavirus (HR-HPV) nucleic acid test designed for low-resource settings; and (2) determine persistence of HR-HPV infection after one-year follow-up to inform optimal screening, treatment, and follow-up algorithms. We co-tested 913 previously unscreened women aged ≥30years and applied WHO-recommended treatment for all VIA/VILI-DC-positive women. Baseline prevalence of HR-HPV and HIV were 24% and 42%, respectively. On initial screen, 44 (5%) women were VIA/VILI-DC-positive, of whom 22 had HR-HPV infection, indicating 50% of women screened false-positive and would have been triaged for unnecessary same-day treatment. VIA/VILI-DC-positive women with HIV infection were three times more likely to be HR-HPV-positive than HIV-negative women (65% vs. 20%). All women positive for either VIA/VILI-DC or HR-HPV (n=245) were invited for repeat co-testing after one year, of which 136 (56%) returned for follow-up. Of 122 women who were HR-HPV-positive on initial screen, 60 (49%) re-tested negative, of whom 6 had received treatment after initial screen, indicating that 44% of initially HR-HPV-positive women spontaneously cleared infection after one year without treatment. Women with HIV were more likely to remain HR-HPV-positive on follow-up than HIV-negative women (61% vs. 22%, p<0.001). Treatment was offered to all VIA/VILI-DC positive women on initial screen, and to all women screening VIA/VILI-DC or HR-HPV positive on follow-up. We found careHPV co-testing with VIA/VILI-DC to be feasible and valuable in

  18. Accelerated stress testing of thin film solar cells: Development of test methods and preliminary results

    Science.gov (United States)

    Lathrop, J. W.

    1985-01-01

    If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.

  19. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility.

  20. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    International Nuclear Information System (INIS)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub

    2016-01-01

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility

  1. The Art Gallery Test: A Preliminary Comparison between Traditional Neuropsychological and Ecological VR-Based Tests

    Directory of Open Access Journals (Sweden)

    Pedro Gamito

    2017-11-01

    Full Text Available Ecological validity should be the cornerstone of any assessment of cognitive functioning. For this purpose, we have developed a preliminary study to test the Art Gallery Test (AGT as an alternative to traditional neuropsychological testing. The AGT involves three visual search subtests displayed in a virtual reality (VR art gallery, designed to assess visual attention within an ecologically valid setting. To evaluate the relation between AGT and standard neuropsychological assessment scales, data were collected on a normative sample of healthy adults (n = 30. The measures consisted of concurrent paper-and-pencil neuropsychological measures [Montreal Cognitive Assessment (MoCA, Frontal Assessment Battery (FAB, and Color Trails Test (CTT] along with the outcomes from the three subtests of the AGT. The results showed significant correlations between the AGT subtests describing different visual search exercises strategies with global and specific cognitive measures. Comparative visual search was associated with attention and cognitive flexibility (CTT; whereas visual searches involving pictograms correlated with global cognitive function (MoCA.

  2. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  3. TPX: Contractor preliminary design review. Volume 5, Manufacturing R ampersand D

    International Nuclear Information System (INIS)

    Roach, J.F.; Urban, W.M.; Hartman, D.

    1995-01-01

    TPX Insulation ampersand Impregnation R ampersand D test results are reported for 1x2 samples designed for screening candidate conduit insulation systems for TPX PF and TF coils. The epoxy/glass insulation system and three proposed alternate insulation systems employing Kapton, was evaluated in as received sample condition and after 10 thermal cycles in liquid nitrogen. Two DGBA impregnation systems, Shell 826 and CTD101K were investigated. Square incoloy 908 and 316 LN stainless hollow conduits were used for 1x2 sample fabrication. Capacitance, dielectric loss, and insulation resistance dielectric characteristics were measured for all samples. Partial discharge performance was measured for samples either in air, under silicon oil, or under liquid nitrogen up to 10kVrms at 60 Hz. Hipot screening was performed at 10 kVdc. The samples were cross sectioned and evaluated for impregnation quality. The implications of the test results on the TPX preliminary design decision are discussed

  4. Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening.

    Directory of Open Access Journals (Sweden)

    Mercy Nyamewaa Asiedu

    Full Text Available Cervical cancer screening usually requires use of a speculum to provide a clear view of the cervix. The speculum is one potential barrier to screening due to fear of pain, discomfort and embarrassment. The aim of this paper is to present and demonstrate the feasibility of a tampon-sized inserter and the POCkeT Colposcope, a miniature pen sized-colposcope, for comfortable, speculum-free and potentially self-colposcopy.We explored different designs using 3D computer-aided design (CAD software and performed mechanical testing simulations on each. Designs were rapid prototyped and tested using a custom vaginal phantom across a range of vaginal pressures and uterine tilts to select an optimal design. Two final designs were tested with fifteen volunteers to assess cervix visualization, comfort and usability compared to the speculum and the optimal design, the curved-tip inserter, was selected for testing in volunteers.We present a vaginal inserter as an alternative to the standard speculum for use with the POCkeT Colposcope. The device has a slim tubular body with a funnel-like curved tip measuring approximately 2.5 cm in diameter. The inserter has a channel through which a 2 megapixel (MP mini camera with LED illumination fits to enable image capture. Mechanical finite element testing simulations with an applied pressure of 15 cm H2O indicated a high factor of safety (90.9 for the inserter. Testing of the device with a custom vaginal phantom, across a range of supine vaginal pressures and uterine tilts (retroverted, anteverted and sideverted, demonstrated image capture with a visual area comparable to the speculum for a normal/axial positioned uteri and significantly better than the speculum for anteverted and sideverted uteri (p<0.00001. Volunteer studies with self-insertion and physician-assisted cervix image capture showed adequate cervix visualization for 83% of patients. In addition, questionnaire responses from volunteers indicated a 92

  5. [An experimental proficiency test for ability to screen 104 residual pesticides in agricultural products].

    Science.gov (United States)

    Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide

    2003-10-01

    An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.

  6. A Preliminary Analysis of Reactor Performance Test (LOEP) for a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeonil; Park, Su-Ki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The final phase of commissioning is reactor performance test, which is to prove the integrated performance and safety of the research reactor at full power with fuel loaded such as neutron power calibration, Control Absorber Rod/Second Shutdown Rod drop time, InC function test, Criticality, Rod worth, Core heat removal with natural mechanism, and so forth. The last test will be safety-related one to assure the result of the safety analysis of the research reactor is marginal enough to be sure about the nuclear safety by showing the reactor satisfies the acceptance criteria of the safety functions such as for reactivity control, maintenance of auxiliaries, reactor pool water inventory control, core heat removal, and confinement isolation. After all, the fuel integrity will be ensured by verifying there is no meaningful change in the radiation levels. To confirm the performance of safety equipment, loss of normal electric power (LOEP), possibly categorized as Anticipated Operational Occurrence (AOO), is selected as a key experiment to figure out how safe the research reactor is before turning over the research reactor to the owner. This paper presents a preliminary analysis of the reactor performance test (LOEP) for a research reactor. The results showed how different the transient between conservative estimate and best estimate will look. Preliminary analyses have shown all probable thermal-hydraulic transient behavior of importance as to opening of flap valve, minimum critical heat flux ratio, the change of flow direction, and important values of thermal-hydraulic parameters.

  7. Tuberculosis Screening and Targeted Testing of College and University Students

    Science.gov (United States)

    Journal of American College Health, 2011

    2011-01-01

    Screening and targeted testing for tuberculosis (TB) is a key strategy for controlling and preventing infection on college and university campuses. Early detection provides an opportunity to promote the health of affected individuals through prompt diagnosis and treatment while preventing potential spread to others. Implementation of a screening…

  8. Evaluation of the preliminary auditory profile test battery in an international multi-centre study

    NARCIS (Netherlands)

    van Esch, T.E.M.; Kollmeier, B.; Vormann, M.; Lijzenga, J.; Houtgast, T.; Hallgren, M.; Larsby, B.; Athalye, S.P.; Lutman, M.E.; Dreschler, W.A.

    2013-01-01

    Objective: This paper describes the composition and international multi-centre evaluation of a battery of tests termed the preliminary auditory profile. It includes measures of loudness perception, listening effort, speech perception, spectral and temporal resolution, spatial hearing, self-reported

  9. The validity of the Brain Injury Cognitive Screen (BICS) as a neuropsychological screening assessment for traumatic and non-traumatic brain injury.

    Science.gov (United States)

    Vaughan, Frances L; Neal, Jo Anne; Mulla, Farzana Nizam; Edwards, Barbara; Coetzer, Rudi

    2017-04-01

    The Brain Injury Cognitive Screen (BICS) was developed as an in-service cognitive assessment battery for acquired brain injury patients entering community rehabilitation. The BICS focuses on domains that are particularly compromised following TBI, and provides a broader and more detailed assessment of executive function, attention and information processing than comparable screening assessments. The BICS also includes brief assessments of perception, naming, and construction, which were predicted to be more sensitive to impairments following non-traumatic brain injury. The studies reported here examine preliminary evidence for its validity in post-acute rehabilitation. In Study 1, TBI patients completed the BICS and were compared with matched controls. Patients with focal lesions and matched controls were compared in Study 2. Study 3 examined demographic effects in a sample of normative data. TBI and focal lesion patients obtained significantly lower composite memory, executive function and attention and information processing BICS scores than healthy controls. Injury severity effects were also obtained. Logistic regression analyses indicated that each group of BICS memory, executive function and attention measures reliably differentiated TBI and focal lesion participants from controls. Design Recall, Prospective Memory, Verbal Fluency, and Visual Search test scores showed significant independent regression effects. Other subtest measures showed evidence of sensitivity to brain injury. The study provides preliminary evidence of the BICS' sensitivity to cognitive impairment caused by acquired brain injury, and its potential clinical utility as a cognitive screen. Further validation based on a revised version of the BICS and more normative data are required.

  10. Patient Preferences Regarding Colorectal Cancer Screening: Test Features and Cost Willing to Pay Out of Pocket.

    Science.gov (United States)

    Moreno, Courtney C; Weiss, Paul S; Jarrett, Thomas L; Roberts, David L; Mittal, Pardeep K; Votaw, John R

    2016-01-01

    The purpose of this investigation was to evaluate whether test features would make an individual more or less likely to undergo colorectal cancer screening and how much an individual would be willing to pay out of pocket for a screening test. The methods include an administration of a survey to consecutive adult patients of a general medicine clinic. The survey consisted of Likert-scale questions assessing the patients' likelihood of choosing a screening test based on various test characteristics. Additional questions measured the patients' age, race, gender, and maximum out-of-pocket cost they would be willing to pay. Chi-square tests were used to assess the associations between the likelihood questions and the various demographic characteristics. In results, survey response rate was 88.8% (213 of 240). Respondents were 48.4% female (103 of 213), 51.6% male (110 of 213), 82.6% White (176 of 213), 11.3% African-American (24 of 213), and 6.1% other (13 of 213). Risk of internal injury and light exposure to radiation were the least desirable test features. Light sedation was the only test feature that most respondents (54.8%) indicated would make them likely or very likely to undergo a colorectal cancer screening test. The vast majority of respondents (86.8%) were willing to pay less than $200 out of pocket for a colorectal cancer screening test. There was no statistically significant difference in the responses of males and females, or in the responses of individuals of different races or different ages regarding test features, or the amount individuals were willing to pay for a screening test. To conclude, survey results suggest that patient education emphasizing the low complication rate of computed tomographic colonography (CTC), the minimal risks associated with the low-level radiation exposure resulting from CTC, and the benefits of a sedation-free test (eg, no risk of sedation-related complication and no need for a driver) may increase patient acceptance of

  11. Preliminary identification of potentially disruptive scenarios at the Greater Confinement Disposal Facility, Area 5 of the Nevada Test Site

    International Nuclear Information System (INIS)

    Guzowski, R.V.; Newman, G.

    1993-12-01

    The Greater Confinement Disposal location is being evaluated to determine whether defense-generated transuranic waste buried at this location complies with the Containment Requirements established by the US Environmental Protection Agency. One step in determining compliance is to identify those combinations of events and processes (scenarios) that define possible future states of the disposal system for which performance assessments must be performed. An established scenario-development procedure was used to identify a comprehensive set of mutually exclusive scenarios. To assure completeness, 761 features, events, processes, and other listings (FEPS) were compiled from 11 references. This number was reduced to 205 primarily through the elimination of duplications. The 205 FEPs were screened based on site-specific, goal-specific, and regulatory criteria. Four events survived screening and were used in preliminary scenario development: (1) exploratory drilling penetrates a GCD borehole, (2) drilling of a withdrawal/injection well penetrates a GCD borehole, (3) subsidence occurs at the RWMS, and (4) irrigation occurs at the RWMS. A logic diagram was used to develop 16 scenarios from the four events. No screening of these scenarios was attempted at this time. Additional screening of the currently retained events and processes will be based on additional data and information from site-characterization activities. When screening of the events and processes is completed, a final set of scenarios will be developed and screened based on consequence and probability of occurrence

  12. Impact on colorectal cancer mortality of screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Fedeli, Ugo; Schievano, Elena; Bovo, Emanuela; Guzzinati, Stefano; Baracco, Susanna; Fedato, Chiara; Saugo, Mario; Dei Tos, Angelo Paolo

    2015-05-01

    Colorectal cancer (CRC) screening programmes based on the guaiac faecal occult blood test (gFOBT) reduce CRC-specific mortality. Several studies have shown higher sensitivity with the faecal immunochemical test (FIT) compared with gFOBT. We carried out an ecological study to evaluate the impact of FIT-based screening programmes on CRC mortality. In the Veneto Region (Italy), biennial FIT-based screening programmes that invited 50-69-year-old residents were introduced in different areas between 2002 and 2009. We compared CRC mortality rates from 1995 to 2011 between the areas where screening started in 2002-2004 (early screening areas (ESA)) and areas that introduced the screening in 2008-2009 (late screening areas (LSA)) using Poisson regression models. We also compared available data on CRC incidence rates (1995-2007) and surgical resection rates (2001-2012). Before the introduction of screening, CRC mortality and incidence rates in the two areas were similar. Compared with 1995-2000, 2006-2011 mortality rates were 22% lower in the ESA than in the LSA (rate ratio (RR)=0.78; 95% CI 0.68 to 0.89). The reduction was larger in women (RR=0.64; CI 0.51 to 0.80) than in men (RR=0.87; CI 0.73 to 1.04). In the ESA, incidence and surgery rates peaked during the introduction of the screening programme and then returned to the baseline (2006-2007 incidence) or dropped below initial values (surgery after 2007). FIT-based screening programmes were associated with a significant reduction in CRC mortality. This effect took place much earlier than reported by gFOBT-based trials and observational studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Pain on Functional Movement Screen Tests and Injury Risk.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle C; Anderson, Morgan K; North, William J; Jones, Bruce H

    2015-11-01

    The Functional Movement Screen (FMS) is a tool intended to evaluate limitations or asymmetries of movement to detect individuals at risk for exercise- and sports-related injury. The purpose was to determine the association and predictive value of specific FMS tests with injury risk in physically active men. Soldiers aged 18-57 years completed the FMS (n = 2,476). Demographic and fitness data were collected by survey. Medical record data for any, overuse, and traumatic injury 6 months after the assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated along with receiver operator characteristics to determine area under the curve (AUC). Risks, risk ratios, odds ratios (ORs), and 95% confidence intervals were calculated to assess injury risks. Multivariate logistic regression identified that pain on 5 of the 7 tests was associated with greater risk for any injury (OR = 1.50-3.51): deep squat, hurdle step, in-line lunge, trunk stability push-up, and rotary stability. However, FMS registered low sensitivity, PPV, and AUC for all 7 tests for the 3 injury types (2-24% sensitivity, 16-74% PPV, and 50-58% AUC). Although the presence of pain was associated with a higher risk of injury on 5 tests, a low sensitivity, PPV, and AUC were displayed. Therefore, caution is advised when implementing the FMS as a screening tool in an Army or similarly active population as it could lead to prevention and treatment resources being directed toward individuals who are not at greater risk for injury.

  14. Influence of mechanical stress level in preliminary stress-corrosion testing on fatigue strength of a low-carbon steel

    International Nuclear Information System (INIS)

    Aleskerova, S.A.; Pakharyan, V.A.

    1978-01-01

    Effect of corrosion and mechanical factors of preliminary stress corrosion of a metal in its fatigue strength, has been investigated. Smooth cylindrical samples of 20 steel have been tested. Preliminary corrosion under stress has been carried out under natural sea conditions. It is shown that mechanical stresses in the case of preliminary corrosion affect fatigue strength of low-carbon steels, decreasing the range of limited durability and fatigue limit. This effect increases with the increase of stress level and agressivity of corrosive medium

  15. Preliminary report on fire protection research program (July 6, 1977 test)

    International Nuclear Information System (INIS)

    Klamerus, L.J.

    1977-10-01

    This preliminary report describes a fire test performed at Sandia Laboratories on an array of cable trays filled with fire retardant (IEEE 383 qualified) electrical cable. The cable trays were arranged in an open-space horizontal configuration with the separation distances of Regulatory Guide 1.75 between those trays representing redundant safety divisions. Propane burners were used to produce a fully developed cable fire in one tray which then was allowed to interact with other trays. From this test it appears that it is possible for a fire to propagate across the vertical separation distance between safety divisions, if a fully developed cable fire is the initiating event

  16. Serological Testing in Screening for Adult Celiac Disease

    Directory of Open Access Journals (Sweden)

    Helen Rachel Gillett

    1999-01-01

    Full Text Available Assays for celiac-related antibodies are becoming widely available, and the present review aims to clarify the use of these investigations in the diagnosis of, management of and screening for adult celiac disease. The sensitivities and specificities of various antibody tests are discussed, along with their clinical use as an adjunct to small bowel biopsy, and as a first-line investigation for patients with atypical symptoms of celiac disease or patients at high risk of developing sprue.

  17. Preliminary Test for Constitutive Models of CAP

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yeon Joon; Hong, Soon Joon; Hwang, Su Hyun; Lee, Keo Hyung; Kim, Min Ki; Lee, Byung Chul [FNC Tech., Seoul (Korea, Republic of); Ha, Sang Jun; Choi, Hoon [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2010-05-15

    The development project for the domestic design code was launched to be used for the safety and performance analysis of pressurized light water reactors. As a part of this project, CAP (Containment Analysis Package) code has been developing for the containment safety and performance analysis side by side with SPACE. The CAP code treats three fields (vapor, continuous liquid and dispersed drop) for the assessment of containment specific phenomena, and is featured by assessment capabilities in multi-dimensional and lumped parameter thermal hydraulic cell. Thermal hydraulics solver was developed and has a significant progress now. Implementation of the well proven constitutive models and correlations are essential in other for a containment code to be used with the generalized or optimized purposes. Generally, constitutive equations are composed of interfacial and wall transport models and correlations. These equations are included in the source terms of the governing field equations. In order to develop the best model and correlation package of the CAP code, various models currently used in major containment analysis codes, such as GOTHIC, CONTAIN2.0 and CONTEMPT-LT are reviewed. Several models and correlations were incorporated for the preliminary test of CAP's performance and test results and future plans to improve the level of execution besides will be discussed in this paper

  18. Preliminary Test for Constitutive Models of CAP

    International Nuclear Information System (INIS)

    Choo, Yeon Joon; Hong, Soon Joon; Hwang, Su Hyun; Lee, Keo Hyung; Kim, Min Ki; Lee, Byung Chul; Ha, Sang Jun; Choi, Hoon

    2010-01-01

    The development project for the domestic design code was launched to be used for the safety and performance analysis of pressurized light water reactors. As a part of this project, CAP (Containment Analysis Package) code has been developing for the containment safety and performance analysis side by side with SPACE. The CAP code treats three fields (vapor, continuous liquid and dispersed drop) for the assessment of containment specific phenomena, and is featured by assessment capabilities in multi-dimensional and lumped parameter thermal hydraulic cell. Thermal hydraulics solver was developed and has a significant progress now. Implementation of the well proven constitutive models and correlations are essential in other for a containment code to be used with the generalized or optimized purposes. Generally, constitutive equations are composed of interfacial and wall transport models and correlations. These equations are included in the source terms of the governing field equations. In order to develop the best model and correlation package of the CAP code, various models currently used in major containment analysis codes, such as GOTHIC, CONTAIN2.0 and CONTEMPT-LT are reviewed. Several models and correlations were incorporated for the preliminary test of CAP's performance and test results and future plans to improve the level of execution besides will be discussed in this paper

  19. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  20. Preliminary Design of a LSA Aircraft Using Wind Tunnel Tests

    Directory of Open Access Journals (Sweden)

    Norbert ANGI

    2015-12-01

    Full Text Available This paper presents preliminary results concerning the design and aerodynamic calculations of a light sport aircraft (LSA. These were performed for a new lightweight, low cost, low fuel consumption and long-range aircraft. The design process was based on specific software tools as Advanced Aircraft Analysis (AAA, XFlr 5 aerodynamic and dynamic stability analysis, and Catia design, according to CS-LSA requirements. The calculations were accomplished by a series of tests performed in the wind tunnel in order to assess experimentally the aerodynamic characteristics of the airplane.

  1. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2010-06-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  2. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2007-08-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  3. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    International Nuclear Information System (INIS)

    Lee C. Cadwallader

    2007-01-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with 'generic' component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance

  4. What do Cochrane systematic reviews say about the clinical effectiveness of screening and diagnostic tests for cancer?

    Directory of Open Access Journals (Sweden)

    André Tito Pereira Bueno

    Full Text Available ABSTRACT CONTEXT AND OBJECTIVE: The purpose of screening tests for cancer is to detect it at an early stage in order to increase the chances of treatment. However, their unrestrained use may lead to unnecessary examinations, overdiagnosis and higher costs. It is thus necessary to evaluate their clinical effects in terms of benefits and harm. DESIGN AND SETTING: Review of Cochrane systematic reviews, carried out in the Discipline of Evidence-Based Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo. METHODS: Cochrane reviews on the clinical effectiveness of cancer screening procedures were included. Study titles and abstracts were independently assessed by two authors. Conflicts were resolved by another two authors. Findings were summarized and discussed. RESULTS: Seventeen reviews were selected: fifteen on screening for specific cancers (bladder, breast, colorectal, hepatic, lung, nasopharyngeal, esophageal, oral, prostate, testicular and uterine and two others on cancer in general. The quality of evidence of the findings varied among the reviews. Only two reviews resulted in high-quality evidence: screening using low-dose computed tomography scans for high-risk individuals seems to reduce lung cancer mortality; and screening using flexible sigmoidoscopy and fecal occult blood tests seems to reduce colorectal cancer mortality. CONCLUSION: The evidence found through Cochrane reviews did not support most of the commonly used screening tests for cancer. It is recommended that patients should be informed of the possibilities of false positives and false negatives before they undergo the tests. Further studies to fully assess the effectiveness of cancer screening tests and adverse outcomes are required.

  5. The King-Devick test as a concussion screening tool administered by sports parents.

    Science.gov (United States)

    Leong, D F; Balcer, L J; Galetta, S L; Liu, Z; Master, C L

    2014-02-01

    Sports-related concussion has received increasing awareness due to short- and long-term neurologic sequelae seen among athletes. The King-Devick (K-D) test captures impairment of eye movements and other correlates of suboptimal brain function. We investigated the K-D test as a screening for concussion when administered by layperson sports parents in a cohort of amateur boxers. The K-D test was administered pre-fight and post-fight by laypersons masked to the head trauma status of each athlete. Matches were watched over by a ringside physician and boxing trainer. Athletes with suspected head trauma received testing with the Military Acute Concussion Evaluation (MACE) by the ringside physician to determine concussion status. Athletes sustaining concussion were compared to the athletes screened using the K-D test. Post-fight K-D scores were lower (better) than the best baseline score (41 vs. 39.3 s, P=0.34, Wilcoxon signed-rank test), in the absence of concussion. One boxer sustained a concussion as determined by the ringside physician. This boxer was accurately identified by the layperson K-D testers due to a worsening in K-D test compared to baseline (3.2 seconds) and an increased number of errors. High levels of test-retest reliability were observed (intraclass correlation coefficient 0.90 [95% CI 0.84-0.97]). Additionally, 6 boxers who participated in multiple bouts showed no worsening of their K-D times further supporting that scores are not affected by the fatigue associated with sparring. The K-D test is a rapid sideline screening tool for concussion that can be effectively administered by non-medically trained laypersons.

  6. Evaluation of a Screening Test for Female College Athletes with Eating Disorders and Disordered Eating

    Science.gov (United States)

    Nagel, Deborah L.; Black, David R.; Leverenz, Larry J.; Coster, Daniel C.

    2000-01-01

    Objective: To develop a screening test to detect female college athletes with eating disorders/disordered eating (ED/ DE). No validated eating disorder screening tests specifically for athletes have been available. Design and Setting: In this cross-sectional study, subjects from a large midwestern university completed 3 objective tests and a structured diagnostic interview. Measurements: A new test, developed and pilot tested by the researchers (Athletic Milieu Direct Questionnaire, AMDQ), and 2 tests normed for the general population (Eating Disorder Inventory-2, Bulimia Test-Revised) were used to identify ED/DE athletes. A structured, validated, diagnostic interview (Eating Disorder Examination, version 12.OD) was used to determine which test was most effective in screening female college athletes. Subjects: Subjects included 149 female athletes, ages 18 to 25 years, from 11 Division I and select club sports. Results: ED/DE subjects (35%) were found in almost every sport. Of the ED/DE subjects, 65% exhibited disordered eating, 25% were bulimic, 8% were classified as eating disordered not otherwise specified (NOS), and 2% were anorexic. The AMDQ more accurately identified ED/DE than any test or combination of items. The AMDQ produced superior results on 7 of 9 epidemiologic analyses; sensitivity was 80% and specificity was 77%, meaning that it correctly classified approximately 4 of every 5 persons who were truly exhibiting an eating disorder or disordered eating. Conclusions: We recommend that the AMDQ subsets, which met statistical criteria, be used to screen for ED/DE to enable early identification of athletes at the disordered eating or NOS stage and to initiate interventions before the disorder progresses. PMID:16558658

  7. The validity of the Michigan Alcoholism Screening Test (MAST)

    DEFF Research Database (Denmark)

    Storgaard, H; Nielsen, S D; Gluud, C

    1994-01-01

    This review examines the validity of the Michigan Alcoholism Screening Test (MAST) as a screening instrument for alcohol problems. Studies that compare the MAST-questionnaire with other defined diagnostic criteria of alcohol problems were retrieved through MEDLINE and a cross-bibliographic check....... A total of 20 validity studies were included. The studies varied considerably regarding the prevalence of alcohol problems, the diagnostic criteria, and the examined patient categories. The MAST compared with other diagnostic criteria of alcohol problems gave validity measures with the following span...... and the specificities show substantial variations. The variables that seem to have the largest influence on the PVpos seem to be the prevalence of alcohol problems, the diagnostic method against which the MAST-questionnaire is validated, and the populations on which the MAST is applied. The MAST should in the future...

  8. Preliminary results of hydrologic testing: The composite Umtanum basalt flow top at borehole RRL-2 (3,568 - 3,781 feet)

    International Nuclear Information System (INIS)

    Strait, S.R.; Spane, F.A. Jr.

    1982-11-01

    This report presents preliminary results and description of hydrologic test activities for the composite Umtanum basalt flow top (3,568--3,781 feet) at Borehole RRL-2. Hydrologic tests conducted include two constant discharge air-lift and four slug tests. Preliminary results indicate an observed hydraulic head for the test interval of 405.7 feet above mean sea level. Transmissivity values determined from hydrologic tests performed, range between 244 to 481 ft 2 /day, with an assigned best estimate of 480 ft 2 /day. The best estimate of equivalent hydraulic conductivity, based on an effective test thickness of 157 feet, is 3.1 ft/day. 7 refs., 9 figs., 3 tabs

  9. A focus group study of consumer attitudes toward genetic testing and newborn screening for deafness.

    Science.gov (United States)

    Burton, Sarah K; Withrow, Kara; Arnos, Kathleen S; Kalfoglou, Andrea L; Pandya, Arti

    2006-12-01

    Progress in identifying genes for deafness together with implementation of universal audiologic screening of newborns has provided the opportunity for more widespread use of molecular tests to detect genetic forms of hearing loss. Efforts to assess consumer attitudes toward these advances have lagged behind. Consumer focus groups were held to explore attitudes toward genetic advances and technologies for hearing loss, views about newborn hearing screening, and reactions to the idea of adding molecular screening for hearing loss at birth. Focus group discussions were recorded, transcribed and analyzed. Five focus groups with 44 participants including hearing parents of deaf children, deaf parents and young deaf adults were held. Focus group participants supported the use of genetic tests to identify the etiology of hearing loss but were concerned that genetic information might influence reproductive decisions. Molecular newborn screening was advocated by some; however, others expressed concern about its effectiveness. Documenting the attitudes of parents and other consumers toward genetic technologies establishes the framework for discussions on the appropriateness of molecular newborn screening for hearing loss and informs specialists about potential areas of public education necessary prior to the implementation of such screening.

  10. INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Kalinich

    1999-09-27

    Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be included as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.

  11. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  12. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  13. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Science.gov (United States)

    2010-04-01

    ..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  14. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  15. Development of a Pitch Discrimination Screening Test for Preschool Children.

    Science.gov (United States)

    Abramson, Maria Kulick; Lloyd, Peter J

    2016-04-01

    There is a critical need for tests of auditory discrimination for young children as this skill plays a fundamental role in the development of speaking, prereading, reading, language, and more complex auditory processes. Frequency discrimination is important with regard to basic sensory processing affecting phonological processing, dyslexia, measurements of intelligence, auditory memory, Asperger syndrome, and specific language impairment. This study was performed to determine the clinical feasibility of the Pitch Discrimination Test (PDT) to screen the preschool child's ability to discriminate some of the acoustic demands of speech perception, primarily pitch discrimination, without linguistic content. The PDT used brief speech frequency tones to gather normative data from preschool children aged 3 to 5 yrs. A cross-sectional study was used to gather data regarding the pitch discrimination abilities of a sample of typically developing preschool children, between 3 and 5 yrs of age. The PDT consists of ten trials using two pure tones of 100-msec duration each, and was administered in an AA or AB forced-choice response format. Data from 90 typically developing preschool children between the ages of 3 and 5 yrs were used to provide normative data. Nonparametric Mann-Whitney U-testing was used to examine the effects of age as a continuous variable on pitch discrimination. The Kruskal-Wallis test was used to determine the significance of age on performance on the PDT. Spearman rank was used to determine the correlation of age and performance on the PDT. Pitch discrimination of brief tones improved significantly from age 3 yrs to age 4 yrs, as well as from age 3 yrs to the age 4- and 5-yrs group. Results indicated that between ages 3 and 4 yrs, children's auditory discrimination of pitch improved on the PDT. The data showed that children can be screened for auditory discrimination of pitch beginning with age 4 yrs. The PDT proved to be a time efficient, feasible tool for

  16. Exploring general practitioners' experience of informing women about prenatal screening tests for foetal abnormalities: A qualitative focus group study

    Directory of Open Access Journals (Sweden)

    Meiser Bettina

    2008-05-01

    Full Text Available Abstract Background Recent developments have made screening tests for foetal abnormalities available earlier in pregnancy and women have a range of testing options accessible to them. It is now recommended that all women, regardless of their age, are provided with information on prenatal screening tests. General Practitioners (GPs are often the first health professionals a woman consults in pregnancy. As such, GPs are well positioned to inform women of the increasing range of prenatal screening tests available. The aim of this study was to explore GPs experience of informing women of prenatal genetic screening tests for foetal abnormality. Methods A qualitative study consisting of four focus groups was conducted in metropolitan and rural Victoria, Australia. A discussion guide was used and the audio-taped transcripts were independently coded by two researchers using thematic analysis. Multiple coders and analysts and informant feedback were employed to reduce the potential for researcher bias and increase the validity of the findings. Results Six themes were identified and classified as 'intrinsic' if they occurred within the context of the consultation or 'extrinsic' if they consisted of elements that impacted on the GP beyond the scope of the consultation. The three intrinsic themes were the way GPs explained the limitations of screening, the extent to which GPs provided information selectively and the time pressures at play. The three extrinsic factors were GPs' attitudes and values towards screening, the conflict they experienced in offering screening information and the sense of powerlessness within the screening test process and the health care system generally. Extrinsic themes reveal GPs' attitudes and values to screening and to disability, as well as raising questions about the fundamental premise of testing. Conclusion The increasing availability and utilisation of screening tests, in particular first trimester tests, has expanded GPs

  17. Preliminary analysis of accelerated space flight ionizing radiation testing

    Science.gov (United States)

    Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.

    1982-01-01

    A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

  18. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet.

    Science.gov (United States)

    Northrup, Jason C; Lapierre, Coady; Kirk, Jeffrey; Rae, Cosette

    2015-07-28

    The Internet Process Addiction Test (IPAT) was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term "Internet addiction" is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT) demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  19. Preliminary screening and identification of the hepatocarcinoma cell-binding peptide

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Wu Hua

    2004-01-01

    Objective: To explore the feasibility of screening and isolating homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display random peptide library and to develop a new peptide which may be potentially used as targeting delivery carrier in the biological targeted diagnosis or therapy for liver cancer. Methods: A 12-mer peptide phage display library was used to screen and isolate peptides that bind to human hepatocarcinoma cells, and four rounds of subtractive panning were carried out with the human hepatocarcinoma cell line HepG2 as the target. The affinities of selected phage clones for human hepatocarcinoma cells were determined with enzyme-linked immunosorbent assay (ELISA) and compared with that to human liver cell and other tumor cells of different tissue origins, respectively. In addition, the binding site in the tumor cells was observed with immunofluorescence analysis under confocal light microscopy. The amino acid sequences of phages that bind HepG2 specifically were deduced through DNA sequencing. Based on the results of DNA sequence, a 16-mer peptide (WH16) was designed and synthesized. Binding ability of the new peptide, WH16, was determined with competitive inhibition test. Results: After four rounds of panning, the phages that were bound to and internalized in human hepatocarcinoma cells were isolated. ELISA and immunofluorescence analysis confirmed the affinity of these phages for hepatocarcinoma cells. 56.67%(17/30) of the isolated phages displayed repeated sequence FLLEPHLMDTSM, and FLEP was defined as conservative motif . Binding of the selected phage to HepG2 cells was inhibited by synthesized peptide WH16, that strongly support that cellular binding of the phage is mediated through its displayed peptide, and WH16 can also bind to HepG2. Conclusions: It is feasible to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display random peptide

  20. Preliminary screening and identification of the hepatocarcinoma cell-binding peptide

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohua, Zhu; Hua, Wu [Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong Univ. of Science and Technology, Wuhan (China)

    2004-12-15

    Objective: To explore the feasibility of screening and isolating homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display random peptide library and to develop a new peptide which may be potentially used as targeting delivery carrier in the biological targeted diagnosis or therapy for liver cancer. Methods: A 12-mer peptide phage display library was used to screen and isolate peptides that bind to human hepatocarcinoma cells, and four rounds of subtractive panning were carried out with the human hepatocarcinoma cell line HepG2 as the target. The affinities of selected phage clones for human hepatocarcinoma cells were determined with enzyme-linked immunosorbent assay (ELISA) and compared with that to human liver cell and other tumor cells of different tissue origins, respectively. In addition, the binding site in the tumor cells was observed with immunofluorescence analysis under confocal light microscopy. The amino acid sequences of phages that bind HepG2 specifically were deduced through DNA sequencing. Based on the results of DNA sequence, a 16-mer peptide (WH16) was designed and synthesized. Binding ability of the new peptide, WH16, was determined with competitive inhibition test. Results: After four rounds of panning, the phages that were bound to and internalized in human hepatocarcinoma cells were isolated. ELISA and immunofluorescence analysis confirmed the affinity of these phages for hepatocarcinoma cells. 56.67%(17/30) of the isolated phages displayed repeated sequence FLLEPHLMDTSM, and FLEP was defined as conservative motif . Binding of the selected phage to HepG2 cells was inhibited by synthesized peptide WH16, that strongly support that cellular binding of the phage is mediated through its displayed peptide, and WH16 can also bind to HepG2. Conclusions: It is feasible to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display random peptide

  1. Preliminary results of hydrologic testing of the Umtanum Basalt Fracture Zone at borehole RRL-2 (3,781 to 3,827 ft)

    International Nuclear Information System (INIS)

    Strait, S.R.; Spane, F.A. Jr.

    1983-02-01

    This report presents preliminary results and description of hydrologic test activities for the Umtanum Basalt Fracture Zone at Borehole RRL-2, within the test interval 3,781 to 3,827 feet. Hydrologic tests conducted include two short-term, constant discharge pumping tests and two slug tests. Preliminary results indicate an observed hydraulic head for the test interval of 406.7 feet above mean sea level. Transmissivity values determined from hydrologic tests performed range between 205 and 881 ft 2 /day. The best estimate of equivalent hydraulic conductivity, based on an effective test thickness of 6 feet, is 147 ft/day. 8 refs., 6 figs., 3 tabs

  2. Validity of Forced Eyelid Closure Test: A Novel Clinical Screening Test for Ocular Myasthenia Gravis.

    Science.gov (United States)

    Apinyawasisuk, Supanut; Zhou, Xinkai; Tian, Jack J; Garcia, Giancarlo A; Karanjia, Rustum; Sadun, Alfredo A

    2017-09-01

    Forced eyelid closure test (FECT) is a clinical screening test developed from the original Cogan lid twitch (CLT) sign to assist in the diagnosis of ocular myasthenia gravis (OMG), We evaluated the sensitivity and specificity of FECT compared with CLT and benchmarked to standard diagnostic tests. This study was a retrospective chart review of 48 patients using electronic medical records of those that presented with ptosis and/or diplopia at Doheny Eye Institute, University of California, Los Angeles between February 2015 and April 2016. Patients without FECT testing were excluded. FECT and CLT results, and final diagnosis were recorded. To perform FECT, the patient was asked to squeeze his or her eyelids shut for 5-10 seconds then open quickly and fixate in primary position. The excessive upward overshoot of eyelids movement indicated a positive FECT. The test was performed by a neuro-ophthalmologist before establishing the diagnosis. Patients who had equivocal test results and/or inconclusive final diagnosis were excluded. Of the 48 patients studied, 18 patients (37.5%) had positive FECT; 15 of whom had a final diagnosis of OMG (83.3%). Of the 30 patients with negative FECT, 1 had OMG (3.3%). Of the 48 patients, 35 patients also had a documented CLT result (72.9%). CLT was positive in 11 of these 35 patients (31.4%), and 9 of these 11 had OMG (81.8%). Of the 24 patients with negative CLT, 2 of them had OMG (8.3%). Sensitivity and specificity of FECT were 94% and 91% (joint 95% confidence region: sensitivity × specificity = [0.70, 1] × [0.75, 1]). The relative true-positive fraction (rTPF) between FECT and CLT was 1.15; the relative false-positive fraction was 1.31. FECT is a simple clinical screening test with good sensitivity and specificity for OMG.

  3. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    Science.gov (United States)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  4. Geant4 simulation of the response of phosphor screens for X-ray imaging

    International Nuclear Information System (INIS)

    Pistrui-Maximean, S.A.; Freud, N.; Letang, J.M.; Koch, A.; Munier, B.; Walenta, A.H.; Montarou, G.; Babot, D.

    2006-01-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way

  5. Geant4 simulation of the response of phosphor screens for X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pistrui-Maximean, S.A. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)]. E-mail: simona.pistrui@insa-lyon.fr; Freud, N. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Letang, J.M. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Koch, A. [Thales Electron Devices, 38430 Moirans (France); Munier, B. [Thales Electron Devices, 38430 Moirans (France); Walenta, A.H. [Department of Detectors and Electronics, FB Physik, University of Siegen, 57068 Siegen (Germany); Montarou, G. [Corpuscular Physics Laboratory, Blaise Pascal University, 63177 Aubiere Cedex (France); Babot, D. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)

    2006-07-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way.

  6. Hematuria screening test for urinary bladder mucosal infiltration in cervical cancer.

    Science.gov (United States)

    Chuttiangtum, Ayuth; Udomthavornsuk, Banchong; Chumworathayi, Bandit

    2012-01-01

    To determine the diagnostic performance of hematuria as a screening test for urinary bladder infiltration in cervical cancer patients with a prospective study design. Newly diagnosed cervical cancer patients at Srinagarind hospital from 14 June 2011 to 30 April 2012 were enrolled in this study. We collected midstream urine samples for urinalysis from every patient before routine cystoscopic exam for clinical staging. The presence of 3 or more red blood cells (RBCs) per high power field was defined as positive for hematuria. A two-by-two table was used to determine the diagnostic performance of hematuria to detect urinary bladder mucosal infiltration using cystoscopy and biopsy as the gold standard. A total of 130 were patients included, 54 of which (41.5%) had hematuria. Of these, four patients (3.08%) had pathological report from cystoscopic biopsy confirmed metastatic squamous cell carcinoma. The sensitivity, specificity, PPV, NPV, and accuracy of hematuria as a screening test to detect urinary bladder mucosal infiltration of cervical cancer were 100%, 60.3%, 7.4%, 100%, and 61.5%, respectively. There was no single case of urinary bladder mucosal infiltration in patients initially staged less than stage III. Hematuria can be used as a screening test to detect urinary bladder mucosal infiltration of cervical cancer. This can reduce the number of cervical cancer patients who really need to undergo cystoscopy as a staging procedure to less than half and to less than 20% if stage III or more were included without missing a single case of urinary bladder mucosal infiltration.

  7. Cognitive dissonance and attitudes toward unpleasant medical screenings.

    Science.gov (United States)

    Ent, Michael R; Gerend, Mary A

    2016-09-01

    Two studies suggest that cognitive dissonance can lead people to adopt negative attitudes toward beneficial-yet unpleasant-medical screenings. People who thought that they were candidates for an unpleasant medical screening reported less favorable attitudes toward the screening than people who thought that they were ineligible (Study 1). The unpleasantness of a medical screening affected candidates' attitudes toward the screening to a greater extent than non-candidate's attitudes (Study 2). Limitations, including ambiguity regarding the extent to which participants' attitudes were affected specifically by dissonance, are discussed. This preliminary research suggests people attempt to reduce dissonance associated with their anticipated behavior. © The Author(s) 2015.

  8. Parental duties and prenatal screening: does an offer of prenatal screening lead women to believe that they are morally compelled to test?

    Science.gov (United States)

    García, Elisa; Timmermans, Danielle R M; van Leeuwen, Evert

    2012-12-01

    in debates around prenatal screening, it is frequently argued that responsible parenthood implies the acquisition of all available medical information about the health of a fetus, and use of this information to benefit the future child. to analyse whether an offer of a prenatal test leads women to believe that they are morally obliged to control the health of their fetus. a substudy within a randomised controlled trial (RCT) aimed to assess the decision-making process of women when confronted with an offer of a prenatal screening test. 111 women participating in an RCT were retrospectively asked their views on the meaning of testing within their parental duties. testing was described as a personal option that goes beyond the normal parental responsibilities. Participants did not believe that they ought to control the health of the fetus or to avoid disability. A duty to test was only reported when the birth of a disabled child would have a negative impact on family life. women's accounts suggest that two main factors are involved in making testing morally obligatory: (1) the woman's views on her moral duties to her family; and (2) the expected burden of a disabled child on the well-being of the family. A family-centred approach would be more suitable to assess the moral imperative character of testing than women's ethical views about their moral duties towards their unborn child. a test offer should not be limited to communication of the characteristics of screening and the meaning of the test results. In helping women to assess the meaning of testing within their parental duties, counselling should include the family situation in which women have to decide, the women's expectations about living with a child with Down's syndrome or any other disability, and the women's views on their commitments towards their family. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Automated Cervical Screening and Triage, Based on HPV Testing and Computer-Interpreted Cytology.

    Science.gov (United States)

    Yu, Kai; Hyun, Noorie; Fetterman, Barbara; Lorey, Thomas; Raine-Bennett, Tina R; Zhang, Han; Stamps, Robin E; Poitras, Nancy E; Wheeler, William; Befano, Brian; Gage, Julia C; Castle, Philip E; Wentzensen, Nicolas; Schiffman, Mark

    2018-04-11

    State-of-the-art cervical cancer prevention includes human papillomavirus (HPV) vaccination among adolescents and screening/treatment of cervical precancer (CIN3/AIS and, less strictly, CIN2) among adults. HPV testing provides sensitive detection of precancer but, to reduce overtreatment, secondary "triage" is needed to predict women at highest risk. Those with the highest-risk HPV types or abnormal cytology are commonly referred to colposcopy; however, expert cytology services are critically lacking in many regions. To permit completely automatable cervical screening/triage, we designed and validated a novel triage method, a cytologic risk score algorithm based on computer-scanned liquid-based slide features (FocalPoint, BD, Burlington, NC). We compared it with abnormal cytology in predicting precancer among 1839 women testing HPV positive (HC2, Qiagen, Germantown, MD) in 2010 at Kaiser Permanente Northern California (KPNC). Precancer outcomes were ascertained by record linkage. As additional validation, we compared the algorithm prospectively with cytology results among 243 807 women screened at KPNC (2016-2017). All statistical tests were two-sided. Among HPV-positive women, the algorithm matched the triage performance of abnormal cytology. Combined with HPV16/18/45 typing (Onclarity, BD, Sparks, MD), the automatable strategy referred 91.7% of HPV-positive CIN3/AIS cases to immediate colposcopy while deferring 38.4% of all HPV-positive women to one-year retesting (compared with 89.1% and 37.4%, respectively, for typing and cytology triage). In the 2016-2017 validation, the predicted risk scores strongly correlated with cytology (P < .001). High-quality cervical screening and triage performance is achievable using this completely automated approach. Automated technology could permit extension of high-quality cervical screening/triage coverage to currently underserved regions.

  10. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  11. Knowledge of parents regarding newborn screening test, after accessing the website “Babies’ Portal” - Heel prick test

    Directory of Open Access Journals (Sweden)

    Caroline Antonelli Mendes

    Full Text Available ABSTRACT Purpose: to assess the knowledge of mothers about the heel prick test, develop contents on this test to make it available on the "Babies’ Portal" website, evaluate and validate the informative material developed. Methods: this study was conducted in three stages, that is, the first stage which is about a descriptive study involving 105 mothers of newborn children before performing the neonatal screening "Heel Prick Test", the second one consisting in the development of the website "Babies’ Portal", and the third stage, the evaluation and validation of this material carried out by 20 parents of children between zero and 36 months old, who underwent the neonatal screening Heel Prick Test by accessing the website “Babies’ Portal”. Results: although the interviewed mothers knew that their children had the right to be tested, they showed no knowledge of the diseases that can be prevented, time of diagnosis, nor the consequences arising from the lack of early diagnosis and treatment. The website creation and validation gathered basic information about the Heel Prick Test, and the participants regarded the content from satisfactory to excellent. Conclusion: it is necessary that families know not only about the procedures their children will undergo, but also the reason they are performed and the consequences of failing in doing so.

  12. A field test of substance use screening devices as part of routine drunk-driving spot detection operating procedures in South Africa.

    Science.gov (United States)

    Matzopoulos, Richard; Lasarow, Avi; Bowman, Brett

    2013-10-01

    This pilot study aimed to test four substance use screening devices developed in Germany under local South African conditions and assess their utility for detecting driving under the influence of drugs (DUID) as part of the standard roadblock operations of local law enforcement agencies. The devices were used to screen a sample of motorists in the Gauteng and Western Cape provinces. The motorists were diverted for screening at roadblocks at the discretion of the law enforcement agencies involved, as per their standard operating procedures. Fieldworkers also administered a questionnaire that described the screening procedure, as well as information about vehicles, demographic information about the motorists and their attitudes to the screening process during testing. Motorists tested positive for breath alcohol in 28% of the 261 cases tested. Oral fluid was screened for drugs as per the standard calibrated cut-offs of all four devices. There were 14 cases where the under-influence drivers tested positive for alcohol and drugs simultaneously, but 14% of the 269 drivers drug-screened tested positive for drugs only. After alcohol, amphetamine, methamphetamine and cocaine were the most common drugs of impairment detected. The results suggest that under normal enforcement procedures only 76% of drivers impaired by alcohol and other drugs would have been detected. In more than 70% of cases the tests were administered within 5 min and this is likely to improve with more regular use. It was clear that the pilot screening process meets global testing standards. Although use of the screening devices alone would not serve as a basis for prosecution and provisions would need to be made for the confirmation of results through laboratory testing, rollout of this screening process would improve operational efficiency in at least two ways. Firstly, the accuracy of the tests will substantially decrease confirmatory test loads. Secondly, laboratory drug testing can be restricted to

  13. Screening specifications for bedded salt, Salina Basin, New York and Ohio

    International Nuclear Information System (INIS)

    Brunton, G.D.; Laughon, R.B.; McClain, W.C.

    1978-01-01

    A survey of bedded salt deposits in New York and Ohio is planned to identify study areas for potential sites for radioactive waste disposal. Prior to the survey previous geological work related to these deposits will be reviewed. Preliminary screening specifications for the identification of study areas were derived for each of the geological evaluation criteria by application of the significant factors that will have an impact on the reconnaissance survey. These factors were selected by a review of the list of factors associated with each criterion. The procedure for the derivation of each screening specification is discussed. The screening specifications are the official Office of Waste Isolation values to be used for the first-cut acceptance for bedded salt study areas in Ohio and New York. The specifications will be reevaluated and refined for more-detailed investigations at each study area that passes the screening test. The derivation of the screening specifications is illustrated by (1) a statement of the geological evaluation criterion, (2) a discussion of the pertinent factors affecting the criterion, and (3) the evaluation of the value of the specification

  14. Speech-in-noise screening tests by internet, part 3: test sensitivity for uncontrolled parameters in domestic usage

    NARCIS (Netherlands)

    Leensen, Monique C. J.; Dreschler, Wouter A.

    2013-01-01

    The online speech-in-noise test 'Earcheck' is sensitive for noise-induced hearing loss (NIHL). This study investigates effects of uncontrollable parameters in domestic self-screening, such as presentation level and transducer type, on speech reception thresholds (SRTs) obtained with Earcheck.

  15. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  16. An experience of qualified preventive screening: shiraz smart screening software.

    Science.gov (United States)

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  17. De item-reeks van de cognitieve screening test vergeleken met die van de mini-mental state examination

    NARCIS (Netherlands)

    Schmand, B.; Deelman, B. G.; Hooijer, C.; Jonker, C.; Lindeboom, J.

    1996-01-01

    The items of the ¿mini-mental state examination' (MMSE) and a Dutch dementia screening instrument, the ¿cognitive screening test' (CST), as well as the ¿geriatric mental status schedule' (GMS) and the ¿Dutch adult reading test' (DART), were administered to 4051 elderly people aged 65 to 84 years.

  18. Evaluation of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting

    Directory of Open Access Journals (Sweden)

    Ingole N

    2010-01-01

    Full Text Available Purpose: Integrated counselling and testing centres (ICTC provide counselling and blood testing facilities for HIV diagnosis. Oral fluid tests provide an alternative for people whodo not want blood to be drawn. Also, it avoids the risk of occupational exposure. The goal of this study was to evaluate the utility of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting. Materials and Methods: A cross-sectional study was carried out after ethics committee approval in 250 adult ICTC clients. Blood was collected and tested from these clients for HIV diagnosis as per routine policy and the results were considered as the gold standard. Also, after another written informed consent, oral fluid was collected from the clients and tested for the presence of HIV antibodies. Twenty five clients who had and 25 clients who had not completed their secondary school education (Group A and Group B, respectively were also asked to perform and interpret the test on their own and their findings and experiences were noted. Result: The sensitivity, specificity, PPV and NPV of the oral fluid antibody test were 100%, 98.51%, 94.11% and 100%, respectively. Seventy six percent of clients preferred oral fluid testing. Group B found it difficult to perform the test as compared to Group A and this difference was statistically significant (P ≤ 0.05. Conclusion: Oral fluid testing can be used as a screening test for HIV diagnosis; however, confirmation of reactive results by blood-based tests is a must.

  19. Individual differences in aversion to ambiguity regarding medical tests and treatments: association with cancer screening cognitions.

    Science.gov (United States)

    Han, Paul K J; Williams, Andrew E; Haskins, Amy; Gutheil, Caitlin; Lucas, F Lee; Klein, William M P; Mazor, Kathleen M

    2014-12-01

    Aversion to "ambiguity"-uncertainty about the reliability, credibility, or adequacy of information-about medical tests and treatments is an important psychological response that varies among individuals, but little is known about its nature and extent. The purpose of this study was to examine how individual-level ambiguity aversion relates to important health cognitions related to different cancer screening tests. A survey of 1,074 adults, ages 40 to 70 years, was conducted in four integrated U.S. healthcare systems. The Ambiguity Aversion in Medicine (AA-Med) scale, a measure of individual differences in aversion to ambiguity (AA) about medical tests and treatments, was administered along with measures of several cancer screening-related cognitions: perceived benefits and harms of colonoscopy, mammography, and PSA screening, and ambivalence and future intentions regarding these tests. Multivariable analyses were conducted to assess the associations between AA-Med scores and cancer screening cognitions. Individual-level AA as assessed by the AA-Med scale was significantly associated (P ambiguity. Individual-level AA constitutes a measurable, wide-ranging cognitive bias against medical intervention, and more research is needed to elucidate its mechanisms and effects. ©2014 American Association for Cancer Research.

  20. A score based on screening tests to differentiate mild cognitive impairment from subjective memory complaints

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    2013-09-01

    Full Text Available It is not easy to differentiate patients with mild cognitive impairment (MCI from subjective memory complainers (SMC. Assessments with screening cognitive tools are essential, particularly in primary care where most patients are seen. The objective of this study was to evaluate the diagnostic accuracy of screening cognitive tests and to propose a score derived from screening tests. Elderly subjects with memory complaints were evaluated using the Mini Mental State Examination (MMSE and the Brief Cognitive Battery (BCB. We added two delayed recalls in the MMSE (a delayed recall and a late-delayed recall, LDR, and also a phonemic fluency test of letter P fluency (LPF. A score was created based on these tests. The diagnoses were made on the basis of clinical consensus and neuropsychological testing. Receiver operating characteristic curve analyses were used to determine area under the curve (AUC, the sensitivity and specificity for each test separately and for the final proposed score. MMSE, LDR, LPF and delayed recall of BCB scores reach statistically significant differences between groups (P=0.000, 0.03, 0.001 and 0.01, respectively. Sensitivity, specificity and AUC were MMSE: 64%, 79% and 0.75 (cut off <29; LDR: 56%, 62% and 0.62 (cut off <3; LPF: 71%, 71% and 0.71 (cut off <14; delayed recall of BCB: 56%, 82% and 0.68 (cut off <9. The proposed score reached a sensitivity of 88% and 76% and specificity of 62% and 75% for cut off over 1 and over 2, respectively. AUC were 0.81. In conclusion, a score created from screening tests is capable of discriminating MCI from SMC with moderate to good accurancy.

  1. Original Article PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF ...

    African Journals Online (AJOL)

    Sierra Leone 2Department of Pharmaceutical Chemistry, Faculty of Pharmacy, ... the seeds are used in the treatment of skin infections. ... Screening with DPPH showed prominent antioxidant spots on silica at Rf 0.8, 0.5, 0.4 .... underpins conditions like rheumatoid arthritis, ..... As a follow-up to the preliminary TLC studies.

  2. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet

    Directory of Open Access Journals (Sweden)

    Jason C. Northrup

    2015-07-01

    Full Text Available The Internet Process Addiction Test (IPAT was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term “Internet addiction” is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  3. Patterns and predictors of repeat fecal immunochemical and occult blood test screening in four large health care systems in the United States.

    Science.gov (United States)

    Singal, Amit G; Corley, Douglas A; Kamineni, Aruna; Garcia, Michael; Zheng, Yingye; Doria-Rose, Paul V; Quinn, Virginia P; Jensen, Christopher D; Chubak, Jessica; Tiro, Jasmin; Doubeni, Chyke A; Ghai, Nirupa R; Skinner, Celette Sugg; Wernli, Karen; Halm, Ethan A

    2018-02-27

    Effectiveness of fecal occult blood test (FOBT) for colorectal cancer (CRC) screening depends on annual testing, but little is known about patterns of repeat stool-based screening within different settings. Our study's objective was to characterize screening patterns and identify factors associated with repeat screening among patients who completed an index guaiac FOBT (gFOBT) or fecal immunochemical test (FIT). We performed a multi-center retrospective cohort study among people who completed a FOBT between January 2010 and December 2011 to characterize repeat screening patterns over the subsequent 3 years. We studied at 4 large health care delivery systems in the United States. Logistic regression analyses were used to identify factors associated with repeat screening patterns. We included individuals aged 50-71 years who completed an index FOBT and had at least 3 years of follow-up. We excluded people with a history of CRC, colonoscopy within 10 years or flexible sigmoidoscopy within 5 years before the index test, or positive index stool test. Consistent screening was defined as repeat FOBT within every 15 months and inconsistent screening as repeat testing at least once during follow-up but less than consistent screening. Among 959,857 eligible patients who completed an index FIT or gFOBT, 344,103 had three years of follow-up and met inclusion criteria. Of these, 46.6% had consistent screening, 43.4% inconsistent screening, and 10% had no repeat screening during follow-up. Screening patterns varied substantially across healthcare systems, with consistent screening proportions ranging from 1 to 54.3% and no repeat screening proportions ranging from 6.9 to 42.8%. Higher consistent screening proportions were observed in health systems with screening outreach and in-reach programs, whereas the safety-net health system, which uses opportunistic clinic-based screening, had the lowest consistent screening. Consistent screening increased with older age but was less

  4. Cervical Cancer Screening Preferences Among Trans-Masculine Individuals: Patient-Collected Human Papillomavirus Vaginal Swabs Versus Provider-Administered Pap Tests.

    Science.gov (United States)

    McDowell, Michal; Pardee, Dana J; Peitzmeier, Sarah; Reisner, Sari L; Agénor, Madina; Alizaga, Natalie; Bernstein, Ida; Potter, Jennifer

    2017-08-01

    Trans-masculine (TM, i.e., persons who have a masculine spectrum gender identity, but were assigned female sex at birth) individuals face disparities in cervical cancer screening rates compared to cisgender women. Some unique barriers to screening in this population are specific to Pap tests. Introduction of self-collected frontal (i.e., vaginal) swabs for human papillomavirus (HPV) testing as a screening strategy may obviate these barriers. This study elucidates cervical cancer screening preferences among TM individuals. TM individuals participated in in-depth interviews (n = 31) and online surveys (n = 32) to explore perceptions and experiences regarding cervical cancer screening, including the acceptability of self-collected frontal HPV swabs for cervical cancer screening compared to provider-administered Pap tests. Provider-collected frontal HPV swab acceptability was also explored. Most TM individuals (94% in-person and 91% online participants) preferred either the self- or provider-collected frontal HPV swab to the Pap test. Participants perceived self- and provider-collected frontal HPV swabs to be less invasive, provoke less gender discordance, and promote a greater sense of agency compared to Pap tests. However, some participants expressed concern about HPV swab accuracy and, regarding the self-collected swab, discomfort about the need to engage with genitals they may not want to acknowledge. Individuals who reported positive provider relationships found Pap tests and provider-collected frontal swabs more acceptable than those who did not. Frontal HPV swabs have the potential to promote regular cervical cancer screening among TM individuals and to narrow screening disparities. Work is ongoing to establish swab accuracy and develop shared decision-making tools.

  5. Comparison of the clinical performances of the AdvanSure HPV Screening Real-Time PCR, the Abbott Real-Time High-Risk HPV Test, and the Hybrid Capture High-Risk HPV DNA Test for Cervical Cancer Screening.

    Science.gov (United States)

    Chung, Hae-Sun; Hahm, Chorong; Lee, Miae

    2014-09-01

    The clinical performance of three human papillomavirus (HPV) DNA commercial assays for cervical cancer screening was evaluated; the AdvanSure HPV Screening Real-Time PCR (AdvanSure PCR; LG Life Sciences) that was developed recently for the detection of both high-risk and low-risk genotypes, the Abbott RealTime High-Risk HPV Test (Abbott PCR; Abbott Molecular) and the Hybrid Capture High-Risk HPV DNA test (HC2; Qiagen). The three different HPV DNA tests were compared using cytology samples obtained from 619 women who underwent routine cervical cancer screening. The gold-standard assay was histopathological confirmation of cervical intraepithelial neoplasia of grade 2 or worse. The clinical sensitivities of the AdvanSure PCR, the Abbott PCR and the HC2 for the detection of cervical intraepithelial neoplasia of grade 2 or worse were 95.5%, 95.5% and 100%, respectively, while the clinical specificities were 61.6%, 86.4% and 83.3%, respectively. There were no significant differences in the clinical sensitivities of the Abbott PCR and the AdvanSure PCR compared to the HC2. The clinical specificities of the Abbott PCR and the AdvanSure PCR for the detection of HPV types 16/18 were 97.8% and 98.5%, respectively. For cervical cancer screening, all three tests showed relatively good clinical sensitivities, but the AdvanSure PCR had lower clinical specificity than the Abbott PCR and the HC2. The AdvanSure PCR and the Abbott PCR assays have the advantage of being automated and the ability to distinguish between HPV types 16/18 and other HPV types. The two real-time PCR assays could be useful tools in HPV testing for cervical cancer screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    Science.gov (United States)

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Type 2 Diabetes Screening Test by Means of a Pulse Oximeter.

    Science.gov (United States)

    Moreno, Enrique Monte; Lujan, Maria Jose Anyo; Rusinol, Montse Torrres; Fernandez, Paqui Juarez; Manrique, Pilar Nunez; Trivino, Cristina Aragon; Miquel, Magda Pedrosa; Rodriguez, Marife Alvarez; Burguillos, M Jose Gonzalez

    2017-02-01

    In this paper, we propose a method for screening for the presence of type 2 diabetes by means of the signal obtained from a pulse oximeter. The screening system consists of two parts: the first analyzes the signal obtained from the pulse oximeter, and the second consists of a machine-learning module. The system consists of a front end that extracts a set of features form the pulse oximeter signal. These features are based on physiological considerations. The set of features were the input of a machine-learning algorithm that determined the class of the input sample, i.e., whether the subject had diabetes or not. The machine-learning algorithms were random forests, gradient boosting, and linear discriminant analysis as benchmark. The system was tested on a database of [Formula: see text] subjects (two samples per subject) collected from five community health centers. The mean receiver operating characteristic area found was [Formula: see text]% (median value [Formula: see text]% and range [Formula: see text]%), with a specificity =  [Formula: see text]% for a threshold that gave a sensitivity = [Formula: see text]%. We present a screening method for detecting diabetes that has a performance comparable to the glycated haemoglobin (haemoglobin A1c HbA1c) test, does not require blood extraction, and yields results in less than 5 min.

  8. Do Men and Women Need to Be Screened Differently with Fecal Immunochemical Testing? A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Meulen, Miriam P van der; Kapidzic, Atija; Leerdam, Monique E van; van der Steen, Alex; Kuipers, Ernst J; Spaander, Manon C W; de Koning, Harry J; Hol, Lieke; Lansdorp-Vogelaar, Iris

    2017-08-01

    Background: Several studies suggest that test characteristics for the fecal immunochemical test (FIT) differ by gender, triggering a debate on whether men and women should be screened differently. We used the microsimulation model MISCAN-Colon to evaluate whether screening stratified by gender is cost-effective. Methods: We estimated gender-specific FIT characteristics based on first-round positivity and detection rates observed in a FIT screening pilot (CORERO-1). Subsequently, we used the model to estimate harms, benefits, and costs of 480 gender-specific FIT screening strategies and compared them with uniform screening. Results: Biennial FIT screening from ages 50 to 75 was less effective in women than men [35.7 vs. 49.0 quality-adjusted life years (QALY) gained, respectively] at higher costs (€42,161 vs. -€5,471, respectively). However, the incremental QALYs gained and costs of annual screening compared with biennial screening were more similar for both genders (8.7 QALYs gained and €26,394 for women vs. 6.7 QALYs gained and €20,863 for men). Considering all evaluated screening strategies, optimal gender-based screening yielded at most 7% more QALYs gained than optimal uniform screening and even resulted in equal costs and QALYs gained from a willingness-to-pay threshold of €1,300. Conclusions: FIT screening is less effective in women, but the incremental cost-effectiveness is similar in men and women. Consequently, screening stratified by gender is not more cost-effective than uniform FIT screening. Impact: Our conclusions support the current policy of uniform FIT screening. Cancer Epidemiol Biomarkers Prev; 26(8); 1328-36. ©2017 AACR . ©2017 American Association for Cancer Research.

  9. Limitations of widely used high-risk human papillomavirus laboratory-developed testing in cervical cancer screening

    Directory of Open Access Journals (Sweden)

    Naryshkin S

    2012-11-01

    Full Text Available Sonya Naryshkin,1 R Marshall Austin21Department of Pathology, Mercy Health System, Janesville, WI; 2Department of Pathology, Magee-Womens Hospital of University of Pittsburgh Medical Center, Pittsburgh, PA, USAObjective: To increase awareness of the limitations of high-risk human papillomavirus (hrHPV laboratory-developed testing (LDT widely used in US cervical cancer screening.Methods and results: A young woman in her 30s was diagnosed and treated for stage 1B1 cervical squamous cell carcinoma in which HPV 16 DNA was detected using polymerase chain reaction testing. Both 1 month before and 42 months before cervical cancer diagnosis, the patient had highly abnormal cytology findings; however, residual SurePath™ (Becton, Dickson and Company, Franklin Lakes, NJ vial fluid yielded negative Hybrid Capture 2 (HC2; Qiagen NV, Hilden, Germany hrHPV LDT results from each of the two specimens. This prompted questions to be asked concerning the performance characteristics of hrHPV LDT. A review of the available data indicates that (1 purification of DNA from SurePath specimens requires complex sample preparation due to formaldehyde crosslinking of proteins and nucleic acids, (2 HC2–SurePath hrHPV testing had not been Food and Drug Administration-approved after multiple premarket approval submissions, (3 detectible hrHPV DNA in the SurePath vial decreases over time, and (4 US laboratories performing HC2–SurePath hrHPV LDT testing are not using a standardized manufacturer-endorsed procedure.Conclusion: Recently updated cervical screening guidelines in the US recommend against the use of hrHPV LDT in cervical screening, including widely used HC2 testing from the SurePath vial. The manufacturer recently issued a technical bulletin specifically warning that use of SurePath samples with the HC2 hrHPV test may provide false negative results and potentially compromise patient safety. Co-collection using a Food and Drug Administration-approved hrHPV test

  10. Antenatal syphilis screening using point-of-care testing in Sub-Saharan African countries: a cost-effectiveness analysis.

    Directory of Open Access Journals (Sweden)

    Andreas Kuznik

    2013-11-01

    Full Text Available Untreated syphilis in pregnancy is associated with adverse clinical outcomes for the infant. Most syphilis infections occur in sub-Saharan Africa (SSA, where coverage of antenatal screening for syphilis is inadequate. Recently introduced point-of-care syphilis tests have high accuracy and demonstrate potential to increase coverage of antenatal screening. However, country-specific cost-effectiveness data for these tests are limited. The objective of this analysis was to evaluate the cost-effectiveness and budget impact of antenatal syphilis screening for 43 countries in SSA and estimate the impact of universal screening on stillbirths, neonatal deaths, congenital syphilis, and disability-adjusted life years (DALYs averted.The decision analytic model reflected the perspective of the national health care system and was based on the sensitivity (86% and specificity (99% reported for the immunochromatographic strip (ICS test. Clinical outcomes of infants born to syphilis-infected mothers on the end points of stillbirth, neonatal death, and congenital syphilis were obtained from published sources. Treatment was assumed to consist of three injections of benzathine penicillin. Country-specific inputs included the antenatal prevalence of syphilis, annual number of live births, proportion of women with at least one antenatal care visit, per capita gross national income, and estimated hourly nurse wages. In all 43 sub-Saharan African countries analyzed, syphilis screening is highly cost-effective, with an average cost/DALY averted of US$11 (range: US$2-US$48. Screening remains highly cost-effective even if the average prevalence falls from the current rate of 3.1% (range: 0.6%-14.0% to 0.038% (range: 0.002%-0.113%. Universal antenatal screening of pregnant women in clinics may reduce the annual number of stillbirths by up to 64,000, neonatal deaths by up to 25,000, and annual incidence of congenital syphilis by up to 32,000, and avert up to 2.6 million

  11. The Functional Movement Screen and modified Star Excursion Balance Test as predictors of T-test agility performance in university rugby union and netball players.

    Science.gov (United States)

    Armstrong, Ross; Greig, Matt

    2018-05-01

    Agility is a functional requirement of many sports, challenging stability, and commonly cited as a mechanism of injury. The Functional Movement Screen (FMS) and modified Star Excursion Balance Test (mSEBT) have equivocally been associated with agility performance. The aim of the current study was to establish a hierarchical ordering of FMS and mSEBT elements in predicting T-test agility performance. Cross-sectional study design. University. Thirty-two female rugby players, 31 male rugby players and 39 female netballers MAIN OUTCOME MEASURES: FMS, mSEBT, T-test performance. The predictive potential of composite FMS and mSEBT scores were weaker than when discrete elements were considered. FMS elements were better predictors of T-test performance in rugby players, whilst mSEBT elements better predicted performance in netballers. Hierarchical modelling highlighted the in-line lunge (ILL) as the primary FMS predictor, whereas mSEBT ordering was limb and sport dependent. The relationship between musculoskeletal screening tools and agility performance was sport-specific. Discrete element scores are advocated over composite scores, and hierarchical ordering of tests might highlight redundancy in screening. The prominence of the ILL in hierarchical modelling might reflect the functional demands of the T-test. Sport-specificity and limb dominance influence hierarchical ordering of musculoskeletal screens. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Role of Urine Drug Testing in the Current Opioid Epidemic.

    Science.gov (United States)

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  13. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Chung, Phil Sang

    2006-01-01

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively (ρ < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease

  14. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon; Chung, Phil Sang [Dankook University Hospital, Cheonan (Korea, Republic of)

    2006-04-15

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively ({rho} < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease.

  15. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    Science.gov (United States)

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study

  16. How many cervical cancer cases can potentially be prevented using a more sensitive screening test at young age?

    NARCIS (Netherlands)

    I.M.C.M. de Kok (Inge); J.M. van Rosmalen (Joost); K. Rozemeijer (Kirsten); C. Penning (Corine); M. van Ballegooijen (Marjolein)

    2014-01-01

    textabstractThe human papilloma virus (HPV) DNA test has higher sensitivity than cytology for cervical cancer screening. Therefore, cervical cancer cases that are missed by cytology could potentially be identified if we use primary HPV testing. Studies showed that HPV screening is the preferred

  17. Estimation of Pap-test coverage in an area with an organised screening program: challenges for survey methods

    Directory of Open Access Journals (Sweden)

    Raggi Patrizio

    2006-03-01

    Full Text Available Abstract Background The cytological screening programme of Viterbo has completed the second round of invitations to the entire target population (age 25–64. From a public health perspective, it is important to know the Pap-test coverage rate and the use of opportunistic screening. The most commonly used study design is the survey, but the validity of self-reports and the assumptions made about non respondents are often questioned. Methods From the target population, 940 women were sampled, and responded to a telephone interview about Pap-test utilisation. The answers were compared with the screening program registry; comparing the dates of Pap-tests reported by both sources. Sensitivity analyses were performed for coverage over a 36-month period, according to various assumptions regarding non respondents. Results The response rate was 68%. The coverage over 36 months was 86.4% if we assume that non respondents had the same coverage as respondents, 66% if we assume they were not covered at all, and 74.6% if we adjust for screening compliance in the non respondents. The sensitivity and specificity of the question, "have you ever had a Pap test with the screening programme" were 84.5% and 82.2% respectively. The test dates reported in the interview tended to be more recent than those reported in the registry, but 68% were within 12 months of each other. Conclusion Surveys are useful tools to understand the effectiveness of a screening programme and women's self-report was sufficiently reliable in our setting, but the coverage estimates were strongly influenced by the assumptions we made regarding non respondents.

  18. Universal Developmental Screening: Preliminary Studies in Galicia, Spain

    Science.gov (United States)

    Sarmiento Campos, Jose A.; Squires, Jane; Ponte, Jaime

    2011-01-01

    "A_Tempo" is a research project that is currently under development in Galicia, an autonomous community of Spain. Its main aim is to propose an effective universal screening procedure for early identification of developmental disorders in children from zero to three years of age who attend Galician pre-primary schools.…

  19. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    Science.gov (United States)

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  20. Memory-Context Effects of Screen Color in Multiple-Choice and Fill-In Tests

    Science.gov (United States)

    Prestera, Gustavo E.; Clariana, Roy; Peck, Andrew

    2005-01-01

    In this experimental study, 44 undergraduates completed five computer-based instructional lessons and either two multiplechoice tests or two fill-in-the-blank tests. Color-coded borders were displayed during the lesson, adjacent to the screen text and illustrations. In the experimental condition, corresponding border colors were shown at posttest.…

  1. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  2. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  3. Prenatal screening and genetics

    DEFF Research Database (Denmark)

    Alderson, P; Aro, A R; Dragonas, T

    2001-01-01

    Although the term 'genetic screening' has been used for decades, this paper discusses how, in its most precise meaning, genetic screening has not yet been widely introduced. 'Prenatal screening' is often confused with 'genetic screening'. As we show, these terms have different meanings, and we...... examine definitions of the relevant concepts in order to illustrate this point. The concepts are i) prenatal, ii) genetic screening, iii) screening, scanning and testing, iv) maternal and foetal tests, v) test techniques and vi) genetic conditions. So far, prenatal screening has little connection...... with precisely defined genetics. There are benefits but also disadvantages in overstating current links between them in the term genetic screening. Policy making and professional and public understandings about screening could be clarified if the distinct meanings of prenatal screening and genetic screening were...

  4. Neuropsychological screening as a standard of care during discharge from psychiatric hospitalization: the preliminary psychometrics of the CNS Screen.

    Science.gov (United States)

    Levy, Boaz; Celen-Demirtas, Selda; Surguladze, Tinatin; Eranio, Sara; Ellison, James

    2014-03-30

    Cost-prohibitive factors currently prevent a warranted integration of neuropsychological screenings into routine psychiatric evaluations, as a standard of care. To overcome this challenge, the current study examined the psychometric properties of a new computerized measure-the CNS Screen. One hundred and twenty six psychiatric inpatients completed the CNS Screen, the Montreal Cognitive Assessment (MoCA), and the Quick Inventory of Depressive Symptomatology-Self Rated (QIDS-SR₁₆) on the day of hospital discharge. Statistical analysis established convergent validity with a moderate correlation between the self-administered CNS Screen and the clinician-administered MoCA (r=0.64). Discriminant validity was implicated by a non-significant correlation with the QIDS-SR₁₆. Concurrent validity was supported by a moderate, negative correlation with patients' age (r=-0.62). In addition, consistent with previous findings, patients with psychotic disorders exhibited significantly poorer performance on the CNS Screen than patients with a mood disorder. Similarly, patients with a formal disability status scored significantly lower than other patients. The CNS Screen was well tolerated by all patients. With further development, this type of measure may provide a cost-effective approach to expanding neuropsychological screenings on inpatient psychiatric units. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Preliminary design studies on the Broad Application Test Reactor

    International Nuclear Information System (INIS)

    Terry, W.J.; Terry, W.K.; Ryskamp, J.M.; Jahshan, S.N.; Fletcher, C.D.; Moore, R.L.; Leyse, C.F.; Ottewitte, E.H.; Motloch, C.G.; Lacy, J.M.

    1992-08-01

    This report describes progress made at the Idaho National Engineering Laboratory during the first three quarters of Fiscal Year (FY) 1992 on the Laboratory-Directed Research and Development (LDRD) project to perform preliminary design studies on the Broad Application Test Reactor (BATR). This work builds on the FY-92 BATR studies, which identified anticipated mission and safety requirements for BATR and assessed a variety of reactor concepts for their potential capability to meet those requirements. The main accomplishment of the FY-92 BATR program is the development of baseline reactor configurations for the two conventional conceptual test reactors recommended in the FY-91 report. Much of the present report consists of descriptions and neutronics and thermohydraulics analyses of these baseline configurations. In addition, we considered reactor safety issues, compared the consequences of steam explosions for alternative conventional fuel types, explored a Molten Chloride Fast Reactor concept as an alternate BATR design, and examined strategies for the reduction of operating costs. Work planned for the last quarter of FY-92 is discussed, and recommendations for future work are also presented

  6. Preliminary study fo the interference of proteic compounds of radiopharmaceuticals in the test of lisadode amebocitos de limulus (LAL)

    International Nuclear Information System (INIS)

    Aldana, Claudia

    1997-01-01

    In this thesis the objective was evaluate the interference of proteic compounds of the radiopharmaceuticals in the test LAL (lisado of amebocitos de limulus) for this, macroagregates of albumina (MAA) was used with metilendifosfonato (MDP) as control that is the radiopharmaceutical more used in the nuclear medicine centers of the country. Initially preliminary test were carried out to assess if some of two radiopharmaceuticals would cause interference with LAL test, after the test was validated and finally routine tests were made. With the preliminary assays was concluded that proteic compounds did not cause interference (albumina with a concentration of 2 md/dl) with the MAA. However with the MDP cause interference with LAL test. The interference was eliminated with a dilution of 1:8 of the sample. Was concluded that the success of LAL test depends on conditions such as temperature, pH, constant incubation (no minimum variations) and that is a good test for quality control of the radiopharmaceuticals

  7. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  8. Creation and preliminary validation of the screening for self-medication safety post-stroke scale (S-5).

    Science.gov (United States)

    Kaizer, Franceen; Kim, Angela; Van, My Tram; Korner-Bitensky, Nicol

    2010-03-01

    Patients with stroke should be screened for safety prior to starting a self-medication regime. An extensive literature review revealed no standardized self-medication tool tailored to the multi-faceted needs of the stroke population. The aim of this study was to create and validate a condition-specific tool to be used in screening for self-medication safety in individuals with stroke. Items were generated using expert consultation and review of the existing tools. The draft tool was pilot-tested on expert stroke clinicians to receive feedback on content, clarity, optimal cueing and domain omissions. The final version was piloted on patients with stroke using a structured interviewer-administered interview. The tool was progressively refined and validated according to feedback from the 11 expert reviewers. The subsequent version was piloted on patients with stroke. The final version includes 16 questions designed to elicit information on 5 domains: cognition, communication, motor, visual-perception and, judgement/executive function/self-efficacy. The Screening for Safe Self-medication post-Stroke Scale (S-5) has been created and validated for use by health professionals to screen self-medication safety readiness of patients after stroke. Its use should also help to guide clinicians' recommendations and interventions aimed at enhancing self-medication post-stroke.

  9. Mineralogical test as a preliminary step for metallurgical proses of Kalan ores

    International Nuclear Information System (INIS)

    Affandi, K.

    1998-01-01

    Mineralogical tests as a preliminary step for hydrometallurgy of Kalan ores, including Eko Remaja and Rirang have been carried out to identify the elements and minerals content which affect the metallurgical process, especially the leaching and purification of uranium. Mineralogical tests have been done by means of radioactive and radioluxugraph tests to identify radioactive minerals; thin specimen analysis, Scanning Electron Microscopy (SEM) to identify elements and morphology, EPMA to analyse qualitatively the elements, X-ray Diffractometer (XRD) to identify of minerals content; and X-ray Fluorescence (XRF) and chemical analyses to determine total elements qualitatively and quantitatively. The experimental results show that the Eko Remaja ores contain uraninite and brannerite, iron and titan oxides, sulfides, phosphates and silicates minerals, while the Rirang ores contain uraninite, monazite and molybdenite

  10. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  11. Transgenic Plants as Low-Cost Platform for Chemotherapeutic Drugs Screening

    Directory of Open Access Journals (Sweden)

    Daniele Vergara

    2015-01-01

    Full Text Available In this work we explored the possibility of using genetically modified Arabidopsis thaliana plants as a rapid and low-cost screening tool for evaluating human anticancer drugs action and efficacy. Here, four different inhibitors with a validated anticancer effect in humans and distinct mechanism of action were screened in the plant model for their ability to interfere with the cytoskeletal and endomembrane networks. We used plants expressing a green fluorescent protein (GFP tagged microtubule-protein (TUA6-GFP, and three soluble GFPs differently sorted to reside in the endoplasmic reticulum (GFPKDEL or to accumulate in the vacuole through a COPII dependent (AleuGFP or independent (GFPChi mechanism. Our results demonstrated that drugs tested alone or in combination differentially influenced the monitored cellular processes including cytoskeletal organization and endomembrane trafficking. In conclusion, we demonstrated that A. thaliana plants are sensitive to the action of human chemotherapeutics and can be used for preliminary screening of drugs efficacy. The cost-effective subcellular imaging in plant cell may contribute to better clarify drugs subcellular targets and their anticancer effects.

  12. SUMA Technology and Newborn Screening Tests for Inherited Metabolic Diseases in Cuba

    Directory of Open Access Journals (Sweden)

    Ernesto Carlos González Reyes PhD

    2016-07-01

    Full Text Available The ultramicroanalytic system (SUMA, created in the 1980s, is a complete system of reagents and instrumentation to perform ultramicroassays combining the sensitivity of the micro-enzyme-linked immunosorbent assay (ELISA tests with the use of ultramicrovolumes. This technology permitted establishing large-scale newborn screening programs (NSPs for metabolic and endocrine disorders in Cuba. This article summarizes the main results of the implementation during the 30 years of SUMA technology in NSP for 5 inherited metabolic diseases, using ultramicroassays developed at the Department of Newborn Screening at the Immunoassay Center. Since 1986, SUMA technology has been used in the Cuban NSP for congenital hypothyroidism, initially studying thyroid hormone in cord serum samples. In 2000, a decentralized program for the detection of hyperphenylalaninemias using heel dried blood samples was initiated. These successful experiences permitted including protocols for screening congenital adrenal hyperplasia, galactosemia, and biotinidase deficiency in 2005. A program for the newborn screening of CH using the thyroid-stimulating hormone Neonatal ultramicro-ELISA was fully implemented in 2010. Nowadays, the NSP is supported by a network of 175 SUMA laboratories. After 30 years, more than 3.8 million Cuban newborns have been screened, and 1002 affected children have been detected. Moreover, SUMA technology has been presented in Latin America for over 2 decades and has contributed to screen around 17 million newborns. These results prove that developing countries can develop appropriate diagnostic technologies for making health care accessible to all.

  13. Easier operation and similar power of 10 g monofilament test for screening diabetic peripheral neuropathy.

    Science.gov (United States)

    Zhang, Qi; Yi, Na; Liu, Siying; Zheng, Hangping; Qiao, Xiaona; Xiong, Qian; Liu, Xiaoxia; Zhang, Shuo; Wen, Jie; Ye, Hongying; Zhou, Linuo; Li, Yiming; Hu, Renming; Lu, Bin

    2018-01-01

    Objective The 10 g Semmes-Weinstein monofilament evaluation (SWME) of 4 sites on each foot is recommended for distal symmetric polyneuropathy screening and diagnosis. A similar method has been proposed to diagnose 'high-risk' (for ulceration) feet, using 3 sites per foot. This study compared the effectiveness of SWME for testing 3, 4 and 10 sites per foot to identify patients with diabetic neuropathy. Methods We included 3497 subjects in a SWME of 10 sites; records from the 10-site SWME were used for a SWME of 3 and 4 sites. Neuropathy symptom scores and neuropathy deficit scores were evaluated to identify patients with diabetic peripheral neuropathy. Results The sensitivities of the 10 g SWME for 3, 4 and 10 sites were 17.8%, 19.0% and 22.4%, respectively. The Kappa coefficients for the SWME tests of 3, 4 and 10 sites were high (range: 0.78-0.93). Conclusions There were no significant differences in the effectiveness of 3-, 4- and 10-site SWME testing for diabetic peripheral neuropathy screening. SWME testing of 3 sites on each foot may be sufficient to screen for diabetic neuropathy.

  14. Preliminary report of an intervention to improve mammography skills of radiologists

    International Nuclear Information System (INIS)

    D'Orsi, C.J.; Karellas, A.; Costanza, M.E.; Gaw, V.P.

    1989-01-01

    This paper presents a preliminary report of an intervention to improve mammography skills of radiologists. Although implementation of the screening guidelines has not occurred as readily as had been anticipated, use of mammograms is increasing. As the demand for this relatively new technology increases, both the availability of the test and the quality of the test done are valid concerns. Until recently, few radiology training programs provided trainees with opportunities to develop these skills. As a result, few radiologists who have been in practice more than five years have had formal training in the interpretation of mammograms. Thus providing practicing radiologists with the opportunities to develop skills in mammographic interpretation will serve to increase both availability and quality of mammographic exams

  15. Decision-analytic modeling to evaluate the long-term effectiveness and cost-effectiveness of HPV-DNA testing in primary cervical cancer screening in Germany

    Directory of Open Access Journals (Sweden)

    Krämer, Alexander

    2010-01-01

    Full Text Available Background: Persistent infections with high-risk types of human papillomavirus (HPV are associated with the development of cervical neoplasia. Compared to cytology HPV testing is more sensitive in detecting high-grade cervical cancer precursors, but with lower specificity. HPV based primary screening for cervical cancer is currently discussed in Germany. Decisions should be based on a systematic evaluation of the long-term effectiveness and cost-effectiveness of HPV based primary screening. Research questions: What is the long-term clinical effectiveness (reduction in lifetime risk of cervical cancer and death due to cervical cancer, life years gained of HPV testing and what is the cost-effectiveness in Euro per life year gained (LYG of including HPV testing in primary cervical cancer screening in the German health care context? How can the screening program be improved with respect to test combination, age at start and end of screening and screening interval and which recommendations should be made for the German health care context? Methods: A previously published and validated decision-analytic model for the German health care context was extended and adapted to the natural history of HPV infection and cervical cancer in order to evaluate different screening strategies that differ by screening interval, and tests, including cytology alone, HPV testing alone or in combination with cytology, and HPV testing with cytology triage for HPV-positive women. German clinical, epidemiological and economic data were used. In the absence of individual data, screening adherence was modelled independently from screening history. Test accuracy data were retrieved from international meta-analyses. Predicted outcomes included reduction in lifetime-risk for cervical cancer cases and deaths, life expectancy, lifetime costs, and discounted incremental cost-effectiveness ratios (ICER. The perspective of the third party payer and 3% annual discount rate were

  16. Preliminary evaluation of a telephone-based smoking cessation intervention in the lung cancer screening setting: A randomized clinical trial.

    Science.gov (United States)

    Taylor, Kathryn L; Hagerman, Charlotte J; Luta, George; Bellini, Paula G; Stanton, Cassandra; Abrams, David B; Kramer, Jenna A; Anderson, Eric; Regis, Shawn; McKee, Andrea; McKee, Brady; Niaura, Ray; Harper, Harry; Ramsaier, Michael

    2017-06-01

    Incorporating effective smoking cessation interventions into lung cancer screening (LCS) programs will be essential to realizing the full benefit of screening. We conducted a pilot randomized trial to determine the feasibility and efficacy of a telephone-counseling (TC) smoking cessation intervention vs. usual care (UC) in the LCS setting. In collaboration with 3 geographically diverse LCS programs, we enrolled current smokers (61.5% participation rate) who were: registered to undergo LCS, 50-77 years old, and had a 20+ pack-year smoking history. Eligibility was not based on readiness to quit. Participants completed pre-LCS (T0) and post-LCS (T1) telephone assessments, were randomized to TC (N=46) vs. UC (N=46), and completed a final 3-month telephone assessment (T2). Both study arms received a list of evidence-based cessation resources. TC participants also received up to 6 brief counseling calls with a trained cessation counselor. Counseling calls incorporated motivational interviewing and utilized the screening result as a motivator for quitting. The outcome was biochemically verified 7-day point prevalence cessation at 3-months post-randomization. Participants (56.5% female) were 60.2 (SD=5.4) years old and reported 47.1 (SD=22.2) pack years; 30% were ready to stop smoking in the next 30 days. TC participants completed an average of 4.4 (SD=2.3) sessions. Using intent-to-treat analyses, biochemically verified quit rates were 17.4% (TC) vs. 4.3% (UC), p<.05. This study provides preliminary evidence that telephone-based cessation counseling is feasible and efficacious in the LCS setting. As millions of current smokers are now eligible for lung cancer screening, this setting represents an important opportunity to exert a large public health impact on cessation among smokers who are at very high risk for multiple tobacco-related diseases. If this evidence-based, brief, and scalable intervention is replicated, TC could help to improve the overall cost

  17. Effects of Soda-Anthraquinone Pulping Variables on the Durian Rind Pulp and Paper Characteristics: A Preliminary Test

    Science.gov (United States)

    Rizal Masrol, Shaiful; Irwan Ibrahim, Mohd Halim; Adnan, Sharmiza; Rahmad Talib, Mohd; Sian, Lau Lee

    2017-08-01

    Good combination of pulping variables is required to obtain the quality pulp and paper characteristics. Thus, in this preliminary work, naturally dried durian rind were pulped under Soda-Anthraquinone (Soda-AQ) pulping process with 18% to 22% alkali charge, 0% to 0.1% Anthraquinone (AQ) charge, 90 minutes to 150 minutes of cooking time and 150°C to 170°C to investigate the effect of pulping variables on the characteristics of the pulp and paper. Pulping condition with 0% of AQ charge was also conducted for comparison. Results indicated that the best screen yield percentage, reject yield percentage, freeness, drainage time, tear index, number of folds and optical properties were shown by the pulp produced with combination of the highest active alkali (22%), AQ charge (0.1%), cooking time (150 minutes) and cooking temperature (170°C) except apparent density, tensile index and burst index. This preliminary result shows that the optimum quality of durian rind pulp as a potential papermaking raw material pulp could be produced by selecting the good combination of pulping variables which influences the pulp and paper characteristics.

  18. Preliminary testing of a planar converter with uranium oxide pellets in the emitter

    International Nuclear Information System (INIS)

    Miskolczy, G.; Lieb, D.P.; Hatch, G.L.

    1992-01-01

    Nuclear reactor thermionic space power systems incorporating thermionic fuel element generally use refractory metal emitters, which contain the nuclear fuel. The purpose of the current work is to determine the effect, if any, of the diffusion of uranium oxide fuel through chemically vapor deposited (CVD) tungsten on converter performance. This paper describes the preliminary testing of the converter to assess the converter performance before any significant diffusion takes place. In testing, the emitter temperature was 1800 K and the collector temperature was varied from 1000 K to 1070 K. Experiments also examined pressure versus loading characteristics of the graphite

  19. CDC Screening Recommendation for Baby Boomers and Hepatitis C Virus Testing in the US Military Health System.

    Science.gov (United States)

    Manjelievskaia, Janna; Brown, Derek; Shriver, Craig D; Zhu, Kangmin

    Chronic hepatitis C virus (HCV) is the most common blood-borne infection in the United States, with an estimated 2.7 to 3.9 million cases as of 2014. In August 2012, the Centers for Disease Control and Prevention (CDC) recommended 1-time HCV testing of all baby boomers. The objectives of this study were to (1) determine the proportion of people screened for HCV in the US Department of Defense Military Health System before and after the CDC screening recommendation for baby boomers and (2) assess whether certain patient or system factors were associated with screening for HCV before and after August 2012. We used a dataset containing 5% of beneficiaries randomly selected from the Military Health System Data Repository medical claims database for the period July 2011 through September 2013. Of 108 223 people eligible for HCV screening during the first period (July 2011 through July 2012), 1812 (1.7%) were screened. Of 109 768 people eligible during the second period (September 2012 through September 2013), 2599 (2.4%) were screened. HCV screening receipt was related to benefit type (Prime before August 2012: adjusted odds ratio [aOR] = 2.16; 95% confidence interval [CI], 1.89-2.46; Prime after August 2012: aOR = 1.93; 95% CI, 1.73-2.16) and care source (direct care before August 2012: aOR = 1.80; 95% CI, 1.57-2.07; direct care after August 2012: aOR = 2.45; 95% CI, 2.18-2.75); male sex (aOR = 1.17; 95% CI, 1.06-1.29) and black race (aOR = 1.20; 95% CI, 1.05-1.37) were associated with HCV testing only before August 2012. Interventions should be implemented to increase awareness and knowledge of the current national HCV testing recommendation among baby boomers to seek out testing and health care providers to perform screening.

  20. Transmission of Hepatitis C Virus From Organ Donors Despite Nucleic Acid Test Screening.

    Science.gov (United States)

    Suryaprasad, A; Basavaraju, S V; Hocevar, S N; Theodoropoulos, N; Zuckerman, R A; Hayden, T; Forbi, J C; Pegues, D; Levine, M; Martin, S I; Kuehnert, M J; Blumberg, E A

    2015-07-01

    Nucleic acid testing (NAT) for hepatitis C virus (HCV) is recommended for screening of organ donors, yet not all donor infections may be detected. We describe three US clusters of HCV transmission from donors at increased risk for HCV infection. Donor's and recipients' medical records were reviewed. Newly infected recipients were interviewed. Donor-derived HCV infection was considered when infection was newly detected after transplantation in recipients of organs from increased risk donors. Stored donor sera and tissue samples were tested for HCV RNA with high-sensitivity quantitative PCR. Posttransplant and pretransplant recipient sera were tested for HCV RNA. Quasispecies analysis of hypervariable region-1 was used to establish genetic relatedness of recipient HCV variants. Each donor had evidence of injection drug use preceding death. Of 12 recipients, 8 were HCV-infected-6 were newly diagnosed posttransplant. HCV RNA was retrospectively detected in stored samples from donor immunologic tissue collected at organ procurement. Phylogenetic analysis showed two clusters of closely related HCV variants from recipients. These investigations identified the first known HCV transmissions from increased risk organ donors with negative NAT screening, indicating very recent donor infection. Recipient informed consent and posttransplant screening for blood-borne pathogens are essential when considering increased risk donors. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  1. Assessment of Prospective Memory – a Validity Study of Memory for Intentions Screening Test

    NARCIS (Netherlands)

    Bezdicek, O.; Raskin, S.A.; Altgassen, A.M.; Ruzicka, E.

    2014-01-01

    Aim: The goal of the present study was to validate the Czech version of the Memory for Intentions (Screening) Test (MIST, 2010). We included standardized testing material, translation of administration and scoring, and assessment of normative data for the MIST in the Czech population. Introduction:

  2. Cross-sectional evaluation of an internet-based hearing screening test in an occupational setting

    NARCIS (Netherlands)

    Sheikh Rashid, Marya; Leensen, Monique Cj; de Laat, Jan Apm; Dreschler, Wouter A.

    2017-01-01

    Objectives The Occupational Earcheck (OEC) is an online internet test to detect high-frequency hearing loss for the purposes of occupational hearing screening. In this study, we evaluated the OEC in an occupational setting in order to assess test sensitivity, specificity, and validity. Methods A

  3. The effect of offering different numbers of colorectal cancer screening test options in a decision aid: a pilot randomized trial

    Directory of Open Access Journals (Sweden)

    Brenner Alison RT

    2008-01-01

    Full Text Available Abstract Background Decision aids can improve decision making processes, but the amount and type of information that they should attempt to communicate is controversial. We sought to compare, in a pilot randomized trial, two colorectal cancer (CRC screening decision aids that differed in the number of screening options presented. Methods Adults ages 48–75 not currently up to date with screening were recruited from the community and randomized to view one of two versions of our previously tested CRC screening decision aid. The first version included five screening options: fecal occult blood test (FOBT, sigmoidoscopy, a combination of FOBT and sigmoidoscopy, colonoscopy, and barium enema. The second discussed only the two most frequently selected screening options, FOBT and colonoscopy. Main outcomes were differences in screening interest and test preferences between groups after decision aid viewing. Patient test preference was elicited first without any associated out-of-pocket costs (OPC, and then with the following costs: FOBT-$10, sigmoidoscopy-$50, barium enema-$50, and colonoscopy-$200. Results 62 adults participated: 25 viewed the 5-option decision aid, and 37 viewed the 2-option version. Mean age was 54 (range 48–72, 58% were women, 71% were White, 24% African-American; 58% had completed at least a 4-year college degree. Comparing participants that viewed the 5-option version with participants who viewed the 2-option version, there were no differences in screening interest after viewing (1.8 vs. 1.9, t-test p = 0.76. Those viewing the 2-option version were somewhat more likely to choose colonoscopy than those viewing the 5-option version when no out of pocket costs were assumed (68% vs. 46%, p = 0.11, but not when such costs were imposed (41% vs. 42%, p = 1.00. Conclusion The number of screening options available does not appear to have a large effect on interest in colorectal cancer screening. The effect of offering differing

  4. Budget impact analysis of chronic kidney disease mass screening test in Japan.

    Science.gov (United States)

    Kondo, Masahide; Yamagata, Kunihiro; Hoshi, Shu-Ling; Saito, Chie; Asahi, Koichi; Moriyama, Toshiki; Tsuruya, Kazuhiko; Konta, Tsuneo; Fujimoto, Shouichi; Narita, Ichiei; Kimura, Kenjiro; Iseki, Kunitoshi; Watanabe, Tsuyoshi

    2014-12-01

    Our recently published cost-effectiveness study on chronic kidney disease mass screening test in Japan evaluated the use of dipstick test, serum creatinine (Cr) assay or both in specific health checkup (SHC). Mandating the use of serum Cr assay additionally, or the continuation of current policy mandating dipstick test only was found cost-effective. This study aims to examine the affordability of previously suggested reforms. Budget impact analysis was conducted assuming the economic model would be good for 15 years and applying a population projection. Costs expended by social insurers without discounting were counted as budgets. Annual budget impacts of mass screening compared with do-nothing scenario were calculated as ¥79-¥-1,067 million for dipstick test only, ¥2,505-¥9,235 million for serum Cr assay only and ¥2,517-¥9,251 million for the use of both during a 15-year period. Annual budget impacts associated with the reforms were calculated as ¥975-¥4,129 million for mandating serum Cr assay in addition to the currently used mandatory dipstick test, and ¥963-¥4,113 million for mandating serum Cr assay only and abandoning dipstick test. Estimated values associated with the reform from ¥963-¥4,129 million per year over 15 years are considerable amounts of money under limited resources. The most impressive finding of this study is the decreasing additional expenditures in dipstick test only scenario. This suggests that current policy which mandates dipstick test only would contain medical care expenditure.

  5. Results of Preliminary Tests of PAR Bunch Cleaning

    CERN Document Server

    Yao, Chihyuan; Grelick, Arthur; Lumpkin, Alex H; Sereno, Nicholas S

    2005-01-01

    A particle accumulator ring (PAR) is used at the Advanced Photon Source (APS) to collect multiple linac bunches and compress them into a 0.3-ns (rms) single bunch for booster injection. A 9.77-MHz fundamental rf system and a 117.3-MHz harmonic rf system are employed for initial beam capture and bunch length compression. Satellite bunches with very low charge form due to rf phase drifts or beam loading change. These satellites, when injected into the booster and then into the storage ring (SR), cause bunch impurity at three buckets from the target bucket. Storage ring and booster bunch cleaning was tried but proved to be difficult due to the top-up mode of operation in the storage ring and tune drift in the booster synchrotron. Recently we implemented a PAR bunch-cleaning system with tune-modulated harmonic rf knockout. Preliminary tests gave a measured SR bunch purity of better than 10

  6. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  7. Static Aeroelastic Deformation Effects in Preliminary Wind-tunnel Tests of Silent Supersonic Technology Demonstrator

    OpenAIRE

    Makino, Yoshikazu; Ohira, Keisuke; Makimoto, Takuya; Mitomo, Toshiteru; 牧野, 好和; 大平, 啓介; 牧本, 卓也; 三友, 俊輝

    2011-01-01

    Effects of static aeroelastic deformation of a wind-tunnel test model on the aerodynamic characteristics are discussed in wind-tunnel tests in the preliminary design phase of the silent supersonic technology demonstrator (S3TD). The static aeroelastic deformation of the main wing is estimated for JAXA 2m x 2m transonic wind-tunnel and 1m x 1m supersonic wind-tunnel by a finite element method (FEM) structural analysis in which its structural model is tuned with the model deformation calibratio...

  8. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    Science.gov (United States)

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  9. Screening specifications for Gulf Coast salt domes

    International Nuclear Information System (INIS)

    Brunton, G.D.; Laughon, R.B.; McClain, W.C.

    1978-01-01

    A reconnaissance survey of the salt domes of Mississippi, Louisiana, and east Texas is being planned to identify study areas for potential sites for radioactive waste disposal. Preliminary screening specifications were derived for each of the geological evaluation criteria by application of the significant factors that will have an impact on the reconnaissance survey. The procedure for the derivation of each screening specification is discussed. The screening specifications are the official OWI values to be used for the first-cut acceptance for salt dome study areas along the Gulf Coast. The derivation of the screening specifications is illustrated by (1) a statement of the geological evaluation criterion, (2) a discussion of the pertinent factors affecting the criterion, and (3) the evaluation of the value of the specification

  10. Persian competing word test: Development and preliminary results in normal children

    Directory of Open Access Journals (Sweden)

    Mohammad Ebrahim Mahdavi

    2008-12-01

    Full Text Available Background and Aim: Assessment of central auditory processing skills needs various behavioral tests in format of a test battery. There is a few Persian speech tests for documenting central auditory processing disorders. The purpose of this study was developing a dichotic test formed of one-syllabic words suitable for evaluation of central auditory processing in Persian language children and reporting its preliminary results in a group of normal children.Materials and Methods: Persian words in competing manner test was developed utilizing most frequent monosyllabic words in children storybooks reported in the previous researches. The test was performed at MCL on forty-five normal children (39 right-handed and 6 left-handed aged 5-11 years. The children did not show any obvious problem in hearing, speech, language and learning. Free (n=28 and directed listening (n=17 tasks were investigated.Results: The results show that in directed listening task, there is significant advantage for performance of pre-cued ear relative to opposite side. Right ear advantage is evident in free recall condition. Average performance of the children in directed recall is significantly better than free recall. Average row score of the test increases with the children age.Conclusion: Persian words in competing manner test as a dichotic test, can show major characteristics of dichotic listening and effect of maturation of central auditory system on it in normal children.

  11. Preliminary selection criteria for the Yucca Mountain Project waste package container material

    International Nuclear Information System (INIS)

    Halsey, W.G.

    1991-01-01

    The Department of Energy's Yucca Mountain Project (YMP) is evaluating a site at Yucca Mountain in Nevada for construction of a geologic repository for the storage of high-level nuclear waste. Lawrence Livermore National Laboratory's (LLNL) Nuclear Waste Management Project (NWMP) has the responsibility for design, testing, and performance analysis of the waste packages. The design is performed in an iterative manner in three sequential phases (conceptual design, advanced conceptual design, and license application design). An important input to the start of the advanced conceptual design is the selection of the material for the waste containers. The container material is referred to as the 'metal barrier' portion of the waste package, and is the responsibility of the Metal Barrier Selection and Testing task at LLNL. The selection will consist of several steps. First, preliminary, material-independent selection criteria will be established based on the performance goals for the container. Second, a variety of engineering materials will be evaluated against these criteria in a screening process to identify candidate materials. Third, information will be obtained on the performance of the candidate materials, and final selection criteria and quantitative weighting factors will be established based on the waste package design requirements. Finally, the candidate materials will be ranked against these criteria to determine whether they meet the mandated performance requirements, and to provide a comparative score to choose the material for advanced conceptual design activities. This document sets forth the preliminary container material selection criteria to be used in screening candidate materials. 5 refs

  12. Triglyceride-based screening tests fail to recognize cardiometabolic disease in African immigrant and African-American men.

    Science.gov (United States)

    Yu, Sophia S K; Ramsey, Natalie L M; Castillo, Darleen C; Ricks, Madia; Sumner, Anne E

    2013-02-01

    The prevalence of cardiometabolic disease in Africa now rivals that of Western nations. Therefore, screening programs that lead to effective prevention of cardiometabolic disease in Africans is imperative. Most screening tests for cardiometabolic disease use triglyceride (TG) levels as a criterion. However, the failure rate of TG-based screening tests in African Americans is high. In Africans, the efficacy of TG-based screening tests is unknown. Our goal was to determine the association between hypertriglyceridemia (TG ≥150 mg/dL) and cardiometabolic disease in African and African-American men. This was a cross-sectional study of 155 men (80 African immigrants, 75 African Americans) [age, 35±9 years, mean±standard deviation (SD), body mass index (BMI) 28.5±5.2 kg/m(2)] who self-identified as healthy. Lipid profiles were performed. Glucose tolerance and insulin resistance was determined by oral glucose tolerance tests (OGTT) and the insulin sensitivity index (S(I)), respectively. Cardiometabolic disease was defined by four possible subtypes--prediabetes, diabetes, insulin resistance, or metabolic triad [hyperinsulinemia, hyperapolipoprotein B, small low-density lipoprotein (LDL) particles]. TG levels were higher in men with cardiometabolic disease than without (88±43 versus 61±26 mg/dL, Pfail to identify both African immigrants and African-American men with cardiometabolic disease. As a consequence, the opportunity for early intervention and prevention is lost.

  13. Biological screening of chitosan derivatives using Artemia spp. (brine shrimp test)

    International Nuclear Information System (INIS)

    Rozaini Mohd Zohdi; Norimah Yusof; Asnah Hassan

    2006-01-01

    The present study reported on the screening of six selected chitosan derivatives using the brine shrimp lethality bioassay. In addition, the irradiation effects towards the compounds at 25 kGy were also studied. Chitosan is a natural polysaccharide derived from chitin, extracted from the exoskeletons of crustaceans and insects as well as walls of some bacteria and fungi. Brine shrimp test is employed for the screening of toxicity of chitosan derivatives. Toxicity test was carried out by adding different concentrations of tested samples to approximately 5 to 15 Artemia salina larvae. Biological activity using the brine shrimp bioassay was recorded as LC 50 i.e. lethal concentration that kills 50% of the larvae within 24 hours of contact with the samples. Compounds are considered toxic when the LC 50 value is lower than 1 mg/ml by brine shrimp bioassay and practically non-toxic when the value is larger. Of the samples tested, none were toxic to the brine shrimp (LC 50 > 1 mg/ml). The LC 50 values of all chitosan derivatives tested, control and irradiated at 25 kGy were above 1 mg/ml thus all tested samples are considered non-toxic. This study demonstrated that irradiation at 25 kGy showed no significant effects towards the toxicity of the chitosan derivatives. After irradiation, only NO-CMC exhibited marked decrease in LC 50 value, reduced by 3-fold from 34.96 mg/ml to 11.07 mg/ml while O-CMC (5.45 mg/ml to 5 mg/ml) showed no clear differences based on rough estimation. This study suggested that brine shrimp bioassay is a simple, reliable and convenient method that could provide useful clues of the relative toxic potential of the sample tested. (Author)

  14. Assessing traumatic event exposure: general issues and preliminary findings for the Stressful Life Events Screening Questionnaire.

    Science.gov (United States)

    Goodman, L A; Corcoran, C; Turner, K; Yuan, N; Green, B L

    1998-07-01

    This article reviews the psychometric properties of the Stressful Life Events Screening Questionnaire (SLESQ), a recently developed trauma history screening measure, and discusses the complexities involved in assessing trauma exposure. There are relatively few general measures of exposure to a variety of types of traumatic events, and most of those that exist have not been subjected to rigorous psychometric evaluation. The SLESQ showed good test-retest reliability, with a median kappa of .73, adequate convergent validity (with a lengthier interview) with a median kappa of .64, and good discrimination between Criterion A and non-Criterion A events. The discussion addresses some of the challenges of assessing traumatic event exposure along the dimensions of defining traumatic events, assessment methodologies, reporting consistency, and incident validation.

  15. Preliminary screening and identification of the peptide binding to hepatocarcinoma cell

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Wu Ha

    2004-01-01

    Objective: The present study was performed to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display of random peptide library with the purpose of developing a new peptide which may be potentially used as target delivery carrier in the biological target diagnosis or therapy for liver cancer. Methods: A peptide 12-mer phage display library was used to screen and isolate peptide that bind to human hepatocarcinoma cell, and four rounds subtractive panning were carried out with the human hepatocarcinoma cell line HepG2 as the target. The affinities of selected phage clones to human hepatocarcinoma cell were determined with ELISA and compared with human liver cell and other tumor cells of different tissue origins respectively. In addition, the binding site in the tumor cells was observed with immunofluorescence analysis under confocal light microscopy. The amino acid sequences of phages that bind HepG2 specifically were deduced though DNA sequencing. Based on the results of DNA sequence, a 16-mer peptide (WH16) was designed and synthesized. Binding ability of the new peptide WH16 was determined with competitive inhibition test. Results: After four rounds panning, the phages that bound to and internalized in human hepatocarcinoma cell were isolated. ELISA and immunofluorescence analysis confirmed the affinity of these phages to hepatpcarcinoma cells 56.57%(17/30) of the isolated phages displayed repeated sequence FLLEPHLMDTSM, and FLEP was defined as conservative motif. Binding of the selected phage to HepG2 cells was inhibited by synthesized peptide WH16, which strongly support that cellular binding of phage is mediated though its displayed peptide and WH16 can also bind to HepG2. Conclusion: It is feasible to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display of random peptide libraries. The sequence of peptide that can bind to

  16. Preliminary screening and identification of the peptide binding to hepatocarcinoma cell

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohua, Zhu; Ha, Wu [Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan (China)

    2004-07-01

    Objective: The present study was performed to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display of random peptide library with the purpose of developing a new peptide which may be potentially used as target delivery carrier in the biological target diagnosis or therapy for liver cancer. Methods: A peptide 12-mer phage display library was used to screen and isolate peptide that bind to human hepatocarcinoma cell, and four rounds subtractive panning were carried out with the human hepatocarcinoma cell line HepG2 as the target. The affinities of selected phage clones to human hepatocarcinoma cell were determined with ELISA and compared with human liver cell and other tumor cells of different tissue origins respectively. In addition, the binding site in the tumor cells was observed with immunofluorescence analysis under confocal light microscopy. The amino acid sequences of phages that bind HepG2 specifically were deduced though DNA sequencing. Based on the results of DNA sequence, a 16-mer peptide (WH16) was designed and synthesized. Binding ability of the new peptide WH16 was determined with competitive inhibition test. Results: After four rounds panning, the phages that bound to and internalized in human hepatocarcinoma cell were isolated. ELISA and immunofluorescence analysis confirmed the affinity of these phages to hepatpcarcinoma cells 56.57%(17/30) of the isolated phages displayed repeated sequence FLLEPHLMDTSM, and FLEP was defined as conservative motif. Binding of the selected phage to HepG2 cells was inhibited by synthesized peptide WH16, which strongly support that cellular binding of phage is mediated though its displayed peptide and WH16 can also bind to HepG2. Conclusion: It is feasible to screen and isolate homing peptides that bind specifically, or preferentially, to hepatocarcinoma cells using phage display of random peptide libraries. The sequence of peptide that can bind to

  17. Design and preliminary testing of a MEMS microphone phased array for aeroacoustic testing of a small-scale wind turbine airfoil

    Energy Technology Data Exchange (ETDEWEB)

    Bale, A.; Orlando, S.; Johnson, D. [Waterloo Univ., ON (Canada). Wind Energy Group

    2010-07-01

    One of the barriers preventing the widespread utilization of wind turbines is the audible sound that they produce. Developing quieter wind turbines will increase the amount of available land onto which wind farms can be built. Noise emissions from wind turbines can be attributed to the aerodynamic effects between the turbine blades and the air surrounding them. A dominant source of these aeroacoustic emissions from wind turbines is known to originate at the trailing edges of the airfoils. This study investigated the flow physics of noise generation in an effort to reduce noise from small-scale wind turbine airfoils. The trailing edge noise was studied on scale-models in wind tunnels and applied to full scale conditions. Microphone phased arrays are popular research tools in wind tunnel aeroacoustic studies because they can measure and locate noise sources. However, large arrays of microphones can be prohibitively expensive. This paper presented preliminary testing of micro-electrical mechanical system (MEMS) microphones in phased arrays for aeroacoustic testing on a small wind turbine airfoil. Preliminary results showed that MEMS microphones are an acceptable low-cost alternative to costly condenser microphones. 19 refs., 1 tab., 11 figs.

  18. Testing for direct genetic effects using a screening step in family-based association studies

    Directory of Open Access Journals (Sweden)

    Sharon M Lutz

    2013-11-01

    Full Text Available In genome wide association studies (GWAS, families based studies tend to have less power to detect genetic associations than population based studies, such as case-control studies. This can be an issue when testing if genes in a family based GWAS have a direct effect on the phenotype of interest or if the genes act indirectly through a secondary phenotype. When multiple SNPs are tested for a direct effect in the family based study, a screening step can be used to minimize the burden of multiple comparisons in the causal analysis. We propose a 2-stage screening step that can be incorporated into the family based association test (FBAT approach similar to the conditional mean model approach in the VanSteen-algorithm [1]. Simulations demonstrate that the type 1 error is preserved and this method is advantageous when multiple markers are tested. This method is illustrated by an application to the Framingham Heart Study.

  19. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    Science.gov (United States)

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  20. Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.

    Science.gov (United States)

    Iskandar, Livia; Braun, Kathryn L; Katz, Alan R

    2015-04-01

    Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.

  1. Preliminary Feasibility, Design, and Hazard Analysis of a Boiling Water Test Loop Within the Idaho National Laboratory Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Gerstner, Douglas M.

    2009-01-01

    The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The ATR and its support facilities are located at the Idaho National Laboratory (INL). A Boiling Water Test Loop (BWTL) is being designed for one of the irradiation test positions within the. The objective of the new loop will be to simulate boiling water reactor (BWR) conditions to support clad corrosion and related reactor material testing. Further it will accommodate power ramping tests of candidate high burn-up fuels and fuel pins/rods for the commercial BWR utilities. The BWTL will be much like the pressurized water loops already in service in 5 of the 9 'flux traps' (region of enhanced neutron flux) in the ATR. The loop coolant will be isolated from the primary coolant system so that the loop's temperature, pressure, flow rate, and water chemistry can be independently controlled. This paper presents the proposed general design of the in-core and auxiliary BWTL systems; the preliminary results of the neutronics and thermal hydraulics analyses; and the preliminary hazard analysis for safe normal and transient BWTL and ATR operation

  2. Preliminary Test of Friction disk type turbine for S-CO{sub 2} cycle application

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Seungjoon; Kim, Hyeon Tae; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    Due to the relatively mild sodium-CO{sub 2} interaction, the S-CO{sub 2} Brayton cycle can reduce the accident consequence compared to the steam Rankine cycle. Also the S-CO{sub 2} power conversion cycle can achieve high efficiency for SFR core thermal condition. Moreover, the S-CO{sub 2} power cycle can reduce the total cycle footprint due to high density of the working fluid. However, the high pressure operating condition and low viscosity of the fluid cause difficulties in designing appropriate seals and multi-stage turbo machineries. To solve the problem for designing turbo machineries in a creative way, KAIST research team tested a friction disk type turbine concept for the S-CO{sub 2} cycle application. In this paper, the investigation of the Tesla turbine and preliminary test results with compressed air are covered. The KAIST research team investigated a friction disk type turbine, named as Tesla turbine, for the S-CO{sub 2} power cycle applications. Due to the robust design of the fiction disk type, the Tesla turbine technology can be utilized not only for S-CO{sub 2} turbo machinery but also for the multi-phase or sludge flow turbo machinery. The preliminary test of lab-scale Tesla turbine with compressed air was conducted. The high pressure vessel was manufactured for the S-CO{sub 2} operating condition. The test will be concentrated on the turbine efficiency measurement under various conditions and development of the design methodology.

  3. Standing the Test of Time: Reference for a Preliminary Ruling

    DEFF Research Database (Denmark)

    Butler, Graham

    2017-01-01

    It is often too easy to forget just how important the preliminary reference procedure is for the functionality of European Union law. For the Court of Justice, there are both formal and informal means of judicial dialogue. This article focuses on the formal means of dialogue through the preliminary...

  4. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Predicting breast screening attendance using machine learning techniques.

    Science.gov (United States)

    Baskaran, Vikraman; Guergachi, Aziz; Bali, Rajeev K; Naguib, Raouf N G

    2011-03-01

    Machine learning-based prediction has been effectively applied for many healthcare applications. Predicting breast screening attendance using machine learning (prior to the actual mammogram) is a new field. This paper presents new predictor attributes for such an algorithm. It describes a new hybrid algorithm that relies on back-propagation and radial basis function-based neural networks for prediction. The algorithm has been developed in an open source-based environment. The algorithm was tested on a 13-year dataset (1995-2008). This paper compares the algorithm and validates its accuracy and efficiency with different platforms. Nearly 80% accuracy and 88% positive predictive value and sensitivity were recorded for the algorithm. The results were encouraging; 40-50% of negative predictive value and specificity warrant further work. Preliminary results were promising and provided ample amount of reasons for testing the algorithm on a larger scale.

  6. Negative screening tests in classical galactosaemia caused by S135L homozygosity.

    LENUS (Irish Health Repository)

    Crushell, E

    2009-06-01

    Classical galactosaemia is relatively common in Ireland due to a high carrier rate of the Q188R GALT mutation. It is screened for using a bacterial inhibition assay (BIA) for free galactose. A Beutler assay on day one of life is performed only in high risk cases (infants of the Traveller community and relatives of known cases). A 16-month-old Irish-born boy of Nigerian origin was referred for investigation of developmental delay, and failure to thrive. He had oral aversion to solids and his diet consisted of cow\\'s milk and milk-based cereal mixes. He was found to have microcephaly, weight <2nd percentile, hepatomegaly and bilateral cataracts. Coagulation screen was normal and transaminases were slightly elevated. His original newborn screen was reviewed and confirmed to have been negative; urinary reducing substances on three separate occasions were negative. Beutler assay demonstrated "absent" red cell galactose-1-phosphate uridyltransferase (GALT) activity. GALT enzyme activity was <0.5 gsubs\\/h per gHb confirming classical galactosaemia. Gal-1-P was elevated at 1.88 micromol\\/gHb. Mutation analysis of the GALT gene revealed S135L homozygosity. S135L\\/S135L galactosaemia is associated with absent red cell GALT activity but with approximately 10% activity in other tissues such as the liver and intestines, probably explaining the negative screening tests and the somewhat milder phenotype associated with this genotype. The patient was commenced on galactose-restricted diet; on follow-up at 2 years of age, growth had normalized but there was global developmental delay. In conclusion, galactosaemia must be considered in children who present with poor growth, hepatomegaly, developmental delay and cataracts and GALT enzyme analysis should be a first line test in such cases. Non-enzymatic screening methods such as urinary reducing substances and BIA for free galactose are not reliable in S135L homozygous galactosaemia.

  7. Self-collection based HPV testing for cervical cancer screening among women living with HIV in Uganda: a descriptive analysis of knowledge, intentions to screen and factors associated with HPV positivity.

    Science.gov (United States)

    Mitchell, Sheona M; Pedersen, Heather N; Eng Stime, Evelyn; Sekikubo, Musa; Moses, Erin; Mwesigwa, David; Biryabarema, Christine; Christilaw, Jan; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S

    2017-01-13

    Women living with HIV (WHIV) are disproportionately impacted by cervical dysplasia and cancer. The burden is greatest in low-income countries where limited or no access to screening exists. The goal of this study was to describe knowledge and intentions of WHIV towards HPV self-collection for cervical cancer screening, and to report on factors related to HPV positivity among women who participated in testing. A validated survey was administered to 87 HIV positive women attending the Kisenyi Health Unit aged 30-69 years old, and data was abstracted from chart review. At a later date, self-collection based HPV testing was offered to all women. Specimens were tested for high risk HPV genotypes, and women were contacted with results and referred for care. Descriptive statistics, Chi Square and Fischer-exact statistical tests were performed. The vast majority of WHIV (98.9%) women did not think it necessary to be screened for cervical cancer and the majority of women had never heard of HPV (96.4%). However, almost all WHIV found self-collection for cervical cancer screening to be acceptable. Of the 87 WHIV offered self-collection, 40 women agreed to provide a sample at the HIV clinic. Among women tested, 45% were oncogenic HPV positive, where HPV 16 or 18 positivity was 15% overall. In this group of WHIV engaged in HIV care, there was a high prevalence of oncogenic HPV, a large proportion of which were HPV genotypes 16 or 18, in addition to low knowledge of HPV and cervical cancer screening. Improved education and cervical cancer screening for WHIV are sorely needed; self-collection based screening has the potential to be integrated with routine HIV care in this setting.

  8. Screening for cognitive dysfunction in Huntington's disease with the clock drawing test.

    Science.gov (United States)

    Terwindt, Paul W; Hubers, Anna A M; Giltay, Erik J; van der Mast, Rose C; van Duijn, Erik

    2016-09-01

    The aim of the study is to investigate the performance of the clock drawing test as a screening tool for cognitive impairment in Huntington's disease (HD) mutation carriers. The performance of the clock drawing test was assessed in 65 mutation carriers using the Shulman and the Freund scoring systems. The mini-mental state examination, the Symbol Digit Modalities Test, the Verbal Fluency Test, and the Stroop tests were used as comparisons for the evaluation of cognitive functioning. Correlations of the clock drawing test with various cognitive tests (convergent validity), neuropsychiatric characteristics (divergent validity) and clinical characteristics were analysed using the Spearman's rank correlation coefficient. Receiver-operator characteristic analyses were performed for the clock drawing test against both the mini-mental state examination and against a composite variable for executive cognitive functioning to assess optimal cut-off scores. Inter-rater reliability was high for both the Shulman and Freund scoring systems (ICC = 0.95 and ICC = 0.90 respectively). The clock drawing tests showed moderate to high correlations with the composite variable for executive cognitive functioning (mean ρ = 0.75) and weaker correlations with the mini-mental state examination (mean ρ = 0.62). Mean sensitivity of the clock drawing tests was 0.82 and mean specificity was 0.79, whereas the mean positive predictive value was 0.66 and the mean negative predictive value was 0.87. The clock drawing test is a suitable screening instrument for cognitive dysfunction in HD, because it was shown to be accurate, particularly so with respect to executive cognitive functioning, and is easy and quick to use. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Development and validation of a new cognitive screening test: The Hong Kong Brief Cognitive Test (HKBC).

    Science.gov (United States)

    Chiu, Helen F K; Zhong, Bao-Liang; Leung, Tony; Li, S W; Chow, Paulina; Tsoh, Joshua; Yan, Connie; Xiang, Yu-Tao; Wong, Mike

    2018-07-01

    To develop and examine the validity of a new brief cognitive test with less educational bias for screening cognitive impairment. A new cognitive test, Hong Kong Brief Cognitive Test (HKBC), was developed based on review of the literature, as well as the views of an expert panel. Three groups of subjects aged 65 or above were recruited after written consent: normal older people recruited in elderly centres, people with mild NCD (neurocognitive disorder), and people with major NCD. The brief cognitive test, Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment Scale (MoCA), were administered to the subjects. The performance of HKBC in differentiating subjects with major NCD, mild NCD, and normal older people were compared with the clinical diagnosis, as well as the MMSE and MoCA scores. In total, 359 subjects were recruited, with 99 normal controls, 132 subjects with major NCD, and 128 with mild NCD. The mean MMSE, MoCA, and HKBC scores showed significant differences among the 3 groups of subjects. In the receiving operating characteristic curve analysis of the HKBC in differentiating normal subjects from those with cognitive impairment (mild NCD + major NCD), the area under the curve was 0.955 with an optimal cut-off score of 21/22. The performances of MMSE and MoCA in differentiating normal from cognitively impaired subjects are slightly inferior to the HKBC. The HKBC is a brief instrument useful for screening cognitive impairment in older adults and is also useful in populations with low educational level. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Computer-assisted static/dynamic renal imaging: a screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Keim, H.J.; Johnson, P.M.; Vaughan, E.D. Jr.; Beg, K.; Follett, D.A.; Freeman, L.M.; Laragh, J.H.

    1979-01-01

    Computer-assisted static/dynamic renal imaging with [ 197 Hg] chlormerodrin and [/sup 99m/Tc] pertechnetate was evaluated prospectively as a screening test for renovascular hypertension. Results are reported for 51 patients: 33 with benign essential hypertension and 18 with renovascular hypertension, and for 21 normal controls. All patients underwent renal arteriography. Patients with significant obesity, renal insufficiency, or renoparenchymal disease were excluded from this study. Independent visual analyses of renal gamma images and time-activity transit curves identified 17 of the 18 patients with renovascular hypertension; one study was equivocal. There were five equivocal and three false-positive results in the essential hypertension and normal control groups. The sensitivity of the method was 94% and the specificity 85%. Since the prevalence of the renovascular subset of hypertension is approximately 5%, the predictive value is only 25%. Inclusion of computer-generated data did not improve this result. Accordingly, this method is not recommended as a primary screening test for renovascular hypertension

  11. Preliminary results on tests of a Cerenkov ring imaging device employing a photoionizing PWC

    Energy Technology Data Exchange (ETDEWEB)

    Durkin, S.; Honma, A.; Leith, D.W.G.S.

    1978-08-01

    A brief description of techniques and problems of ring imaging Cerenkov detectors employing photoionizing PWC's is discussed. Preliminary results on a one dimensional ring imaging device tested at SLAC in May and June of 1978 are then presented. These results include rough measurements of the Cerenkov ring in nitrogen, argon, neon, and helium produced by a collimated positron beam.

  12. Noninvasiv prænatal test er et gennembrud inden for prænatal screening

    DEFF Research Database (Denmark)

    Hornstrup, Louise Stig; Ambye, Louise; Sørensen, Steen

    2016-01-01

    Non-invasive prenatal testing is a breakthrough in prenatal screening Non-invasive prenatal testing (NIPT) using cell-free fetal DNA from the peripheral blood of the pregnant woman has become a possibility within recent years, but is not yet implemented in Denmark. NIPT has proven to be very...

  13. The use of the osmole gap as a screening test for the presence of exogenous substances.

    Science.gov (United States)

    Purssell, Roy A; Lynd, Larry D; Koga, Yoshikata

    2004-01-01

    The rapid and accurate diagnosis of toxic alcohol poisoning due to methanol (methyl alcohol) [MeOH] and ethylene glycol (EG), is paramount in preventing serious adverse outcomes. The quantitative measurement of specific serum levels of these substances using gas chromatography is expensive, time consuming and generally only available at major tertiary-care facilities. Therefore, because these toxic substances are osmotically active and the measurement of serum osmolality is easily performed and more readily available, the presence of an osmole gap (OG) has been adopted as an alternative screening test. By definition, the OG is the difference between the measured serum osmolality determined using the freezing point depression (Osm(m)) and the calculated serum molarity (Mc), which is estimated from the known and readily measurable osmotically active substances in the serum, in particular sodium, urea, glucose, and potassium and ethanol (alcohol). Thus, the OG=Osm(m)-Mc, and an OG above a specific threshold (the threshold of positivity) suggests the presence of unmeasured osmotically active substances, which could be indicative of a toxic exposure. The objectives of this study were to review the principles of evaluating screening tests, the theory behind the OG as a screening test and the literature upon which the adoption of the OG as a screening test has been based. This review revealed that there have been numerous equations derived and proposed for the estimation of the Mc, with the objective of developing empirical evidence of the best equation for the determination of the OG and ultimately the utility of OG as a screening test. However, the methods and statistical analysis employed have generally been inconsistent with recommended guidelines for screening test evaluation and although many equations have been derived, they have not been appropriately validated. Specific evidence of the clinical utility of the OG requires that a threshold of positivity be

  14. PROSTATE CANCER SCREENING: PSA TEST AWARENESS AMONG ADULT MALES.

    Science.gov (United States)

    Obana, Michael; O'Lawrence, Henry

    2015-01-01

    The overall purpose of this study was to determine whether visits to the doctor in the last 12 months, education level, and annual household income for adult males increased the awareness of prostate-specific antigen (PSA) tests. The effect of these factors for the knowledge of PSA exams was performed using statistical analysis. A retrospective secondary database was utilized for this study using the questionnaire in the California Health Interview Survey from 2009. Based on this survey, annual visits to the doctor, higher educational levels attained, and greater take-home pay were statistically significant and the results of the study were equivalent to those hypothesized. This also reflects the consideration of marketing PSA blood test screenings to those adult males who are poor, uneducated, and do not see the doctor on a consistent basis.

  15. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  16. An analysis of the duplicate testing strategy of an Irish immunochemical FOBT colorectal cancer screening programme.

    LENUS (Irish Health Repository)

    Kelley, Leanne

    2013-06-10

    AIM: This study examined the relevance of using a two sample quantitative immunochemical faecal occult blood test (iFOBT or FIT) at a high cut off stringency by the first population-based colorectal cancer (CRC) pilot screening programme in Ireland. METHOD: Approximately ten thousand individuals between the ages of 50-74 years were invited to perform two consecutive FITs. These were analysed in tandem using the OC-Sensor and participants with at least one positive result with a haemoglobin cut off for positivity at 100 ng\\/ml were offered colonoscopy. RESULTS: A total of 5023 (52%) (2177 (43%) male; 2846 (57%) female) individuals with a median age of 64 years participated. At least one positive FIT test was detected from 514 (10%) individuals. From the 419 (82%) patients who proceeded to colonoscopy 17 (4%) had CRC and 132(33%) had an advanced adenoma. The detection rate for these screen relevant lesions was 3% (95% CIs = 2.5% - 3.5%) and the FIT positive + colonoscopy detection rate was 36% (95% CI = 31% - 40%). The numbers needed to colonoscope to find an advanced lesion was 2.8. The two test system detected four (23.5%) additional patients with CRC and 37 (28%) with an advanced adenoma compared with a single test. CONCLUSION: The CRC miss rate estimated for a single test (23.5%) was unacceptably high when the goal was to maximize the discovery of advanced lesions in the initial screening round. We conclude that the two test protocol at a high cut off threshold is suitable to optimize FIT screening in Ireland. This article is protected by copyright. All rights reserved.

  17. The development and preliminary testing of a multimedia patient–provider survivorship communication module for breast cancer survivors

    Science.gov (United States)

    Wen, Kuang-Yi; Miller, Suzanne M.; Stanton, Annette L.; Fleisher, Linda; Morra, Marion E.; Jorge, Alexandra; Diefenbach, Michael A.; Ropka, Mary E.; Marcus, Alfred C.

    2012-01-01

    Objective This paper describes the development of a theory-guided and evidence-based multimedia training module to facilitate breast cancer survivors’ preparedness for effective communication with their health care providers after active treatment. Methods The iterative developmental process used included: (1) theory and evidence-based content development and vetting; (2) user testing; (3) usability testing; and (4) participant module utilization. Results Formative evaluation of the training module prototype occurred through user testing (n = 12), resulting in modification of the content and layout. Usability testing (n = 10) was employed to improve module functionality. Preliminary web usage data (n = 256, mean age = 53, 94.5% White, 75% college graduate and above) showed that 59% of the participants accessed the communication module, for an average of 7 min per login. Conclusion The iterative developmental process was informative in enhancing the relevance of the communication module. Preliminary web usage results demonstrate the potential feasibility of such a program. Practice implications Our study demonstrates survivors’ openness to the use of a web-based communication skills training module and outlines a systematic iterative user and interface program development and testing process, which can serve as a prototype for others considering such an approach. PMID:22770812

  18. The development and preliminary testing of a multimedia patient-provider survivorship communication module for breast cancer survivors.

    Science.gov (United States)

    Wen, Kuang-Yi; Miller, Suzanne M; Stanton, Annette L; Fleisher, Linda; Morra, Marion E; Jorge, Alexandra; Diefenbach, Michael A; Ropka, Mary E; Marcus, Alfred C

    2012-08-01

    This paper describes the development of a theory-guided and evidence-based multimedia training module to facilitate breast cancer survivors' preparedness for effective communication with their health care providers after active treatment. The iterative developmental process used included: (1) theory and evidence-based content development and vetting; (2) user testing; (3) usability testing; and (4) participant module utilization. Formative evaluation of the training module prototype occurred through user testing (n = 12), resulting in modification of the content and layout. Usability testing (n = 10) was employed to improve module functionality. Preliminary web usage data (n = 256, mean age = 53, 94.5% White, 75% college graduate and above) showed that 59% of the participants accessed the communication module, for an average of 7 min per login. The iterative developmental process was informative in enhancing the relevance of the communication module. Preliminary web usage results demonstrate the potential feasibility of such a program. Our study demonstrates survivors' openness to the use of a web-based communication skills training module and outlines a systematic iterative user and interface program development and testing process, which can serve as a prototype for others considering such an approach. Copyright © 2012. Published by Elsevier Ireland Ltd.

  19. PRELIMINARY STUDIES ON THE BEHAVIOURAL EFFECTS OF THE METHANOL EXTRACT OF LEONOTIS NEPETIFOLIA LINN STEM IN MICE

    Science.gov (United States)

    Ayanwuyi, Lydia O.; Kwanashie, Helen O.; Hussaini, Isa M.; Yaro, Abdullahi H.

    2016-01-01

    Background: Leonotis nepetifolia Linn (Lamiaceae) is used in traditional medicine for its calming (tranquilizing) effects. The aim of this study was to determine whether there is any scientific justification for this use. To achieve this purpose, we investigated the behavioural effects of the methanol extract of Leonotis nepetifolia stem (37.5, 75 and 150 mg/kg) in mice. Methods: Acute toxicity studies were carried out on the methanol stem extract of Leonotis nepetifolia to determine the LD50. The behavioural tests employed were diazepam-induced sleep onset and duration, hole board assay for exploratory activity, mouse beam walk assay for motor coordination, and the staircase test for the detection of anxiolytic compounds. Preliminary phytochemical screening was also carried out on the extract. Results: The intraperitoneal LD50 value was found to be 3.8 g/kg. The results showed that the extract significantly prolonged the duration of diazepam-induced sleep at the highest dose (150 mg/kg). There was no observable effect on exploratory activity and motor coordination at the doses tested (37.5, 75 and 150 mg/kg). The extract, however, at 150 mg/kg elicited a significant decrease in the number of rearings in the staircase test, an effect also observed in the group of mice injected with an anxiolytic dose of diazepam. The preliminary phytochemical screening revealed the presence of alkaloids, saponins, glycosides and triterpenoids. Conclusion: The results obtained suggest that the crude methanol extract of Leonotis nepetifolia stem possesses some biologically active constituents with potential anxiolytic activity and thus may justify its traditional use as a tranquilizer. PMID:28852715

  20. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    DEFF Research Database (Denmark)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance....... To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited...... alternative for increasing cervical cancer screening coverage in Norway....

  1. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  2. 77 FR 15101 - Results From Inert Ingredient Test Orders Issued Under EPA's Endocrine Disruptor Screening...

    Science.gov (United States)

    2012-03-14

    ... the selection criteria for endocrine testing under the Safe Drinking Water Act (SDWA). EPA has no...) because the chemicals meet the selection criteria. EPA has no plans to issue further test orders for the... Screening Program (EDSP) and the Federal Food, Drug, and Cosmetic Act (FFDCA). In response to the test...

  3. Colorectal cancer screening

    OpenAIRE

    Plumb, A. A.; Halligan, S.

    2015-01-01

    Colorectal cancer is a major public health burden worldwide. There is clear-cut evidence that screening will reduce colorectal cancer mortality and the only contentious issue is which screening tool to use. Most evidence points towards screening with fecal occult blood testing. The immunochemical fecal occult blood tests have a higher sensitivity than the guaiac-based tests. In addition, their automation and haemoglobin quantification allows a threshold for colonoscopy to be selected that can...

  4. Characteristics, finite element analysis, test description, and preliminary test results of the STM4-120 kinematic Stirling engine

    Science.gov (United States)

    Linker, K. L.; Rawlinson, K. S.; Smith, G.

    1991-10-01

    The Department of Energy's Solar Thermal Program has, as one of its program elements, the development and evaluation of conversion device technologies applicable to dish-electric systems. The primary research and development combines a conversion device (heat engine), solar receiver, and generator mounted at the focus of a parabolic dish concentrator. The Stirling-cycle heat engine was identified as the conversion device for dish-electric with the most potential for meeting the program's goals for efficiency, reliability, and installed cost. To advance the technology toward commercialization, Sandia National Laboratories has acquired a Stirling Thermal Motors, Inc. kinematic Stirling engine, STM4-120, for evaluation. The engine is being bench-tested at Sandia's Engine Test Facility and will be combined later with a solar receiver for on-sun evaluation. This report presents the engine characteristics, finite element analyses of critical engine components, test system layout, instrumentation, and preliminary performance results from the bench test.

  5. A comparison of the absorbed fluorescent treponemal antibody (FTA-ABS) test and other screening tests for treponemal disease in patients attending a venereal disease clinic.

    Science.gov (United States)

    Wilkinson, A E; Scrimgeour, G; Rodin, P

    1972-05-01

    Screening tests-absorbed fluorescent treponemal (FTA-ABS), the Reiter protein complement-fixation (RPCFT), VDRL slide test, automated reagin-and cardiolipin Wassermann reaction-were carried out on 1922 consecutive new patients attending the Whitechapel Clinic over a three-month period.Taking the FTA-ABS test results as an index, the most efficient combination of conventional tests was found to be the RPCFT and automated reagin test. The cardiolipin WR proved to be under-sensitive and of little value compared with the other tests.Forty-two per cent of the 107 sera reactive in the FTA-ABS test were not detected by the RPCFT or ART tests. An assessment based on the TPI test results and clinical findings in these patients is presented. The scope and limitations of the FTA-ABS test as a screening procedure are discussed.

  6. Manufacturing and preliminary tests of a 12 T ''wind and react'' coil

    International Nuclear Information System (INIS)

    Corte, A. della; Pasotti, G.; Sacchetti, N.; Spadoni, M.; Oliva, A.B.; Penco, R.; Parodi, S.; Valle, N.; Specking, W.

    1994-01-01

    As already reported ENEA is engaged in the realization of a 12 T wind and react Nb 3 Sn coil, a subsize magnet designed to simulate many technological problems to be faced in NET-ITER magnets. EM-LMI and Ansaldo are the industrial partners in this project. A preliminary winding has been built and successfully tested. This winding has been cut in pieces and carefully inspected to be sure that the impregnation process after the heat treatment works well. No particular flaws have been detected. Then manufacturing of the 12 T magnet has been started and completed in about three months. Heat treatment, impregnation and electrical tests at 300 K have been successfully performed and the magnet is now ready for final tests. In order to obtain the most significant scientific and technological information from this magnet, the original test program (insertion of the coil in the SULTAN facility) has been modified according to a decision of the Fusion Technology Steering Committee (FTSC) of EURATOM. Details of the new test programs are given in the paper

  7. Validity and reliability of using a self-lavaging device for cytology and HPV testing for cervical cancer screening: findings from a pilot study.

    Directory of Open Access Journals (Sweden)

    Heidi E Jones

    Full Text Available Self-sampling could increase cervical cancer screening uptake. While methods have been identified for human papillomavirus (HPV testing, to date, self-sampling has not provided adequate specimens for cytology. We piloted the validity and reliability of using a self-lavaging device for cervical cytology and HPV testing. We enrolled 198 women in New York City in 2008-2009 from three ambulatory clinics where they received cervical cancer screening. All were asked to use the Delphi Screener™ to self-lavage 1-3 months after clinician-collected index cytological smear (100 normal; 98 abnormal. Women with abnormal cytology results from either specimen underwent colposcopy; 10 women with normal results from both specimens also underwent colposcopy. We calculated sensitivity of self-collected cytology to detect histologically confirmed high grade lesions (cervical intraepithelial neoplasia, CIN, 2+; specificity for histology-negative (CIN 1 or lower, paired cytology negative, or a third cytology negative; and kappa for paired results. One hundred and ninety-seven (99.5% women self-collected a lavage. Seventy-five percent had moderate to excellent cellularity, two specimens were unsatisfactory for cytology. Seven of 167 (4% women with definitive results had CIN2+; one had normal and six abnormal cytology results with the self-lavage (sensitivity = 86%, 95% Confidence Interval, CI: 42, 100. The kappa for paired cytology was low (0.36; 95% CI: 0.25, 0.47 primarily due to clinician specimens with atypical squamous cells of undetermined significance (ASC-US and low grade squamous intraepithelial lesion (LSIL coded as normal using Screener specimens. However, three cases of HSIL were coded as ASC-US and one as normal using Screener specimens. Seventy-three women had paired high-risk HPV tests with a kappa of 0.66 (95% CI: 0.49, 0.84. Based on these preliminary findings, a larger study to estimate the performance of the Screener for co-testing cytology and

  8. Internet-based recruitment system for HIV and STI screening for men who have sex with men in Estonia, 2013: analysis of preliminary outcomes.

    Science.gov (United States)

    Ruutel, K; Lohmus, L; Janes, J

    2015-04-16

    The aim of the current project was to develop an Internet-based recruitment system for HIV and sexually transmitted infection (STI) screening for men who have sex with men (MSM) in Estonia in order to collect biological samples during behavioural studies. In 2013, an Internet-based HIV risk-behaviour survey was conducted among MSM living in Estonia. After completing the questionnaire, all participants were offered anonymous and free-of-charge STI testing. They could either order a urine sample kit by post to screen for chlamydia infections (including lymphogranuloma venereum (LGV)), trichomoniasis, gonorrhoea and Mycoplasma genitalium infections, or visit a laboratory for HIV, hepatitis A virus, hepatitis B virus,hepatitis C virus and syphilis screening. Of 301 participants who completed the questionnaire, 265 (88%),reported that they were MSM. Of these 265 MSM,68 (26%) underwent various types of testing. In the multiple regression analysis, Russian as the first language,previous HIV testing and living in a city or town increased the odds of testing during the study. Linking Internet-based behavioural data collection with biological sample collection is a promising approach. As there are no specific STI services for MSM in Estonia,this system could also be used as an additional option for anonymous and free-of-charge STI screening.

  9. Pre-employment screening of latent tuberculosis infection among healthcare workers using tuberculin skin test and QuantiFERON-TB Gold test at a tertiary care hospital in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Mohamed El-Helaly

    2014-11-01

    Full Text Available Summary: Objective: To assess the agreement between the tuberculin skin test (TST and the QuantiFERON-TB Gold test (QFT-G as pre-employment screening tests for latent tuberculosis infection (LTBI among healthcare workers. Methods: A retrospective cross-sectional study was conducted among 1412 healthcare workers who were screened for LTBI during the period from August 2009 to May 2011 at a tertiary-care hospital in the Kingdom of Saudi Arabia (KSA. The studied population was screened for LTBI using both TST and QFT-G simultaneously. The agreement between both tests was quantified using the Kappa coefficient (κ. Results: Comparing the results of QFT-G with TST, the tests had a significant overall agreement of 73.7% (1040/1412; κ = 0.33; p < 0.01. Negative concordance comprised 60.1% of the results, and positive concordance comprised 13.5%. However, positive TST but negative QFT comprised 16.3% of the results, and negative TST but positive QFT-G comprised 10.1%. Concordance was significantly associated with young age, female gender, Saudi-born nationals, and early career but not job type (clinical versus non-clinical nor status of Bacillus Calmette–Guerin (BCG vaccination. Conclusions: This study demonstrated 73.7% overall agreement between TST and QFT-G results among healthcare workers during pre-employment screening for LTBI. The results need to be confirmed in future studies before recommending QFT-G as a pre-employment screening test for LTBI. Keywords: Latent tuberculosis infection, Healthcare workers, Tuberculin skin test, QuantiFERON-TB Gold test

  10. Preliminary Process Theory does not validate the Comparison Question Test: A comment on Palmatier and Rovner

    NARCIS (Netherlands)

    Ben-Shakar, G.; Gamer, M.; Iacono, W.; Meijer, E.; Verschuere, B.

    2015-01-01

    Palmatier and Rovner (2015) attempt to establish the construct validity of the Comparison Question Test (CQT) by citing extensive research ranging from modern neuroscience to memory and psychophysiology. In this comment we argue that merely citing studies on the preliminary process theory (PPT) of

  11. Comparison among single-phase test, automated screening method and GC/MS for the traceability of ketamine in urine

    Directory of Open Access Journals (Sweden)

    Alice Visione

    2016-12-01

    CONCLUSION Following the law indications, ketamine is not searched: this limit does not make the authorities able to apply the penalties expected for road laws violations. The automation is essential to guarantee the reliability of toxicological screening tests, especially to medico-legal significance. This results highlight the absolutely necessity of the execution of the confirmation test, successively to screening analysis.

  12. A brief review on newborn screening methods for hemoglobinopathies and preliminary results selecting beta thalassemia carriers at birth by quantitative estimation of the HbA fraction.

    Science.gov (United States)

    Mantikou, Eleni; Arkesteijn, Sandra G; Beckhoven van, Jaqueline M; Kerkhoffs, Jean-Louis; Harteveld, Cornelis L; Giordano, Piero Carlo

    2009-12-01

    We present in a brief summary the basic aspects of the most rational technologies used for new born screening (NBS) of the hemoglobinopathies and we report the preliminary results for the identification of beta-thalassemia carriers at birth by measuring the expression of the HbA fraction. Separation and measurement of the Hb fractions in 1.500 cord blood samples collected among the multi-ethnic Dutch population using different methods. By using a cut of thalassemia can be preselected at birth with a reasonable degree of sensitivity and be confirmed by parent analysis.

  13. Stress analysis of HLW containers. Preliminary ring test exercise Compas project

    International Nuclear Information System (INIS)

    1989-01-01

    This document describes the series of experiments and associated calculations performed as the Compas preliminary ring test exercise. A number of mild steel rings, representative of sections through HLW containers, some notched and pre-cracked, were tested in compression right up to and beyond their ultimate load. The Compas project partners independently modelled the behaviour of these rings using their finite element codes. Four different ring types were tested, and each test was repeated three times. For three of the ring types, the three test repetitions gave identical results. The fourth ring, which was not modelled by the partners, had a 4 mm thick layer of weld metal deposited on its surface. The three tests on this ring did not give identical results and suggested that the effect of welding methods should be addressed at a later stage of the project. Fracture was not found to be a significant cause of ring failure. The results of the ring tests were compared with the partners predictions, and additionally some time was spent assessing where the use of the codes could be improved. This exercise showed that the partners codes have the ability to produce results within acceptable limits. Most codes were unable to model stable crack growth. There were indications that some codes would not be able to cope with a significantly more complex three-dimensional analysis

  14. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    OpenAIRE

    Sayed Hadi Sayed Alitabar; Mojtaba Habibi; Maryam Falahatpisheh; Musa Arvin

    2016-01-01

    Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST). Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men) with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. T...

  15. The Addenbrooke's Cognitive Examination Revised as a potential screening test for elderly drivers.

    Science.gov (United States)

    Ferreira, Inês S; Simões, Mário R; Marôco, João

    2012-11-01

    Considerable research has shown that neuropsychological tests are predictive of real-world driving ability. The Mini-Mental State Examination (MMSE) is a brief cognitive test that has been commonly used in the assessment of older drivers. However, this test has inherent problems that limit its validity to evaluate cognitive abilities related to driving and to screen for driving impairments in non-demented people. Therefore, it is useful to test new screening instruments that may predict potential unsafe drivers who require an in-depth neuropsychological assessment in a specialised centre. To date, the utility of the Addenbrooke's Cognitive Examination Revised (ACE-R) as an indicator of driving ability has not been established. In the current study, fifty older drivers (mean age=73.1 years) who were referred for a psychological assessment, the protocol of which included the ACE-R, underwent an on-road driving test. Using linear discriminant analyses, the results highlighted the higher classification accuracy of the ACE-R compared to the MMSE score, particularly for detecting unsafe drivers. Measures of visuospatial and executive functions, which are not incorporated in the MMSE score, had an incremental value in the prediction of driving ability. This emerging brief cognitive test may warrant additional study for use in the fitness to drive assessment of older adults. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. A virtual reality test battery for assessment and screening of spatial neglect.

    Science.gov (United States)

    Fordell, H; Bodin, K; Bucht, G; Malm, J

    2011-03-01

    There is a need for improved screening methods for spatial neglect. To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke. VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11. Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r² = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47-0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was 'easy' to use. Eighty-eight percent reported that they felt 'focused', 'pleased' or 'alert'. No patient had adverse symptoms. The test session took 15 min. The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment. © 2010 John Wiley & Sons A/S.

  17. Utility of quick oculomotor tests for screening the vestibular system in the subacute and chronic populations.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2018-04-01

    The goal of this study was to determine the sensitivity and specificity of some widely used, easily administered clinical tests. Simple tests of oculomotor function have become widely used for clinical screening of patients suspected of having vestibular disorders despite a paucity of evidence showing good statistical support for their use in this highly variable population. Healthy controls with no history of otologic or neurologic disorders (n = 291) were compared to patients with known vestibular disorders (n = 62). All subjects performed passive and active head shaking, un-instrumented head impulse tests (HT), and video head impulse tests (vHIT) recorded with infrared video-oculography. For both passive and active head shaking, using presence/absence of vertigo and of nystagmus, sensitivity was low (<0.40). Sensitivity of presence/absence of saccades on HT was even lower (<0.15). On vHIT, gains were all approximately = 1.0, so sensitivity was very low (approximately 0.15-0.35). Sensitivity and specificity for presence/absence of saccades were moderately poor (less than 0.70). None of these tests are adequate for screening patients in the out-patient clinic for vestibular disorders or for screening people in epidemiologic studies to determine the prevalence of vestibular disorders.

  18. Fecal occult blood test for colorectal cancer screening: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    The colorectal cancer (CRC) screening project was undertaken by the Medical Advisory Secretariat (MAS) in collaboration with the Cancer Care Ontario (CCO).In November 2007, the Ontario Health Technology Advisory Committee (OHTAC) MAS to conduct an evidence-based analysis of the available data with respect to colorectal cancer diagnosis and prevention. The general purpose of the project was to investigate the effectiveness, cost effectiveness, and safety of the various methods and techniques used for colorectal cancer screening in average risk people, 50 years of age and older.The options currently offered for colorectal cancer screening were reviewed and five technologies were selected for review:Computed tomographic (CT) colonographyMagnetic resonance (MR) colonographyWireless capsule endoscopy (PillCam Colon)Fecal occult blood test (FOBT)Flexible sigmoidoscopyIn this review, colonoscopy was considered as the "gold standard" technique by which the effectiveness of all other modalities could be evaluated. An economic analysis was also conducted to determine cost-effectiveness of different screening modalities.Evidence-based analyses have been prepared for each of these technologies, as well as summary document that includes an economic analysis, all of which are presented at the MAS Web site: http://www.health.gov.on.ca/english/providers/program/mas/tech/techmn.html The objective of this evidence review is to examine the effectiveness and cost-effectiveness of fecal occult blood testing (FOBT), including guaiac FOBT (gFOBT) and immunochemical FOBT (iFOBT), for use in colorectal cancer (CRC) screening in asymptomatic, average-risk adults. Specifically: Is the use of gFOBT or iFOBT associated with a reduction in CRC and overall mortality?What are the sensitivity and specificity of gFOBT and iFOBT for the detection of 1) CRC and 2) large polyps (≥ 1 cm)? CRC is the most common cause of non-tobacco related cancer death in Canada. It has been estimated that in 2007, 7

  19. Availability and accessibility of subsidized mammogram screening program in peninsular Malaysia: A preliminary study using travel impedance approach.

    Science.gov (United States)

    Mahmud, Aidalina; Aljunid, Syed Mohamed

    2018-01-01

    lived in sub-urban and rural areas. In summary, availability of mammogram facilities was good in the central and west coast of the peninsula. The overall provider-to-population ratio was lower than recommended. Based on the travel impedance approach used, accessibility to subsidised mammogram screening among the respondents was good in urban areas but deprived in other areas. This study was a preliminary study with limitations. Nonetheless, the evidence suggests that actions have to be taken to improve the accessibility to opportunistic mammogram screening in Malaysia in pursuit of universal health coverage.

  20. Cytology and Human Papillomavirus Testing 6 to 12 Months after ASCUS or LSIL Cytology in Organized Screening To Predict High-Grade Cervical Neoplasia between Screening Rounds

    Science.gov (United States)

    Sjøborg, Katrine D.; Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Alfsen, G. Cecilie; Jonassen, Christine M.

    2012-01-01

    We carried out a prospective study comparing the performance of human papillomavirus (HPV) E6/E7 mRNA (PreTect HPV-Proofer; NorChip, Klokkarstua, Norway) and DNA (Amplicor HPV test; Roche Diagnostics, Basel, Switzerland) triage testing of women 6 to 12 months after atypical-squamous-cells-of-undetermined-significance (ASCUS) or low-grade-squamous-intraepithelial-lesion (LSIL) cytology in organized screening to predict high-grade cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) between screening rounds. Between January 2005 and April 2008, 692 study women with screening-detected ASCUS/LSIL cytology 6 to 12 months earlier returned for HPV mRNA and DNA testing and repeat cytology. The median follow-up time was 3 years, using existing health care facilities. Follow-up test results were available for 625 women. Of the 145 CIN2+ cases detected during the study period, 95 (65.5%) were HPV mRNA positive 6 to 12 months after screening-detected ASCUS/LSIL, 44 (30.4%) were HPV mRNA negative, and 6 (4.1%) were invalid. The corresponding HPV DNA results were 139 (95.9%), 5 (3.4%), and 1 (0.7%), respectively. The cumulative incidences of CIN2+ 3 years after a negative HPV mRNA and DNA test were 10.3% (95% confidence interval [CI], 7.2 to 13.3%) and 1.8% (95% CI, 0.0 to 3.6%), respectively. The cumulative incidences of CIN2+ 3 years after positive HPV mRNA and DNA tests were 52.8% (95% CI, 40.1 to 60.1%) and 41.3% (95% CI, 35.5 to 46.6%), respectively. In conclusion, both positive HPV mRNA and DNA test results have a high enough long-term prediction of CIN2+ risk to consider referral to colposcopy as good practice when performed in delayed triage of women with ASCUS/LSIL cytology. In addition, the low CIN2+ risk among women with a negative Amplicor HPV test in our study confirms its safe use in a clinical setting. PMID:22518869

  1. Concordant testing results between various Human Papillomavirus assays in primary cervical cancer screening

    DEFF Research Database (Denmark)

    de Thurah, Lena; Bonde, Jesper; Hoa Lam, Janni Uyen

    2018-01-01

    OBJECTIVES: Human Papillomavirus (HPV) assays are increasingly used for primary cervical screening and HPV vaccination effect monitoring. We undertook a systematic literature review to determine the concordance in positive test results (i.e., detection of HPV infections) between Hybrid Capture 2 ...

  2. Screening for Elder Abuse among Turkish Older People: Validity of the Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")

    Science.gov (United States)

    Özmete, Emine; Megahead, Hamido A.

    2017-01-01

    Objective: This study aims to adapt "The Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")" (Neale, Hwalek, Scott, Sengstock, & Stahl, 1991) to Turkish and to assess its validity and reliability while determining the factors that affect elder abuse. Method: The sample of the study is composed of 465 elderly women and…

  3. [Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].

    Science.gov (United States)

    Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés

    2018-03-15

    Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.

  4. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II

    1981-05-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders.

  5. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    International Nuclear Information System (INIS)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II.

    1981-01-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders

  6. Preliminary phytochemical screening, Antibacterial potential and GC-MS analysis of two medicinal plant extracts.

    Science.gov (United States)

    Vijayaram, Seerangaraj; Kannan, Suruli; Saravanan, Konda Mani; Vasantharaj, Seerangaraj; Sathiyavimal, Selvam; P, Palanisamy Senthilkumar

    2016-05-01

    The presence study was aimed to catalyze the primary metabolites and their confirmation by using GC-MS analysis and antibacterial potential of leaf extract of two important medicinal plant viz., Eucalyptus and Azadirachta indica. The antibacterial potential of the methanol leaf extract of the studied species was tested against Escherichia coli, Pseudomonas aeruginosa, Klebsiellap neumoniae, Streptococcus pyogens, Staphylococcus aureus using by agar well diffusion method. The higher zone of inhibition (16mm) was observed against the bacterium Pseudomonas aeruginosa at 100μl concentration of methanol leaf extract. Preliminary phytochemical analysis of studied species shows that presence of phytochemical compounds like steroids, phenolic compounds and flavonoids. GC-MS analysis confirms the occurrence of 20 different compounds in the methanol leaf extract of the both studied species.

  7. Comparison of three screening tests for autism in preterm children with birth weights less than 1,500 grams

    Science.gov (United States)

    Dudova, Iva; Markova, Daniela; Kasparova, Martina; Zemankova, Jana; Beranova, Stepanka; Urbanek, Tomas; Hrdlicka, Michal

    2014-01-01

    Background Preterm children seem to be at increased risk for autism spectrum disorders (ASD). Methods Parents of 157 children with birth weights less than 1,500 g (age 2 years, corrected for prematurity; 88 boys, 69 girls) completed screening questionnaires. The screening battery included the Modified Checklist for Autism in Toddlers (M-CHAT), Communication and Symbolic Behavior Scales Developmental Profile Infant-Toddler Checklist (CSBS-DP-ITC), and the Infant/Toddler Sensory Profile (ITSP). Children with disabilities were excluded. All children who screened positive on any of the screening tools were subsequently assessed by clinical examination including the Autism Diagnostic Observation Schedule. Results Fifty-six children (35.7%) screened positive on at least one of the parental screening questionnaires. Of the 56 children who tested positive, 33 participated in the detailed clinical follow-up assessment. A diagnosis of ASD was confirmed in 13 of the 33 children. The ASD prevalence was 9.7% of the sample. Analysis of children with and without an ASD diagnosis found significant differences relative to gestational age (26.9 weeks vs 28.3 weeks, P=0.033) and length of the stay in hospital (89.5 days vs 75.4 days, P=0.042). The screening tool with the most positive results was CSBS-DP-ITC (42 positive screens [PS]), followed by M-CHAT (28 PS), and ITSP (22 PS). Differences in the frequency of PS among the tests were significant (P=0.008). CSBS-DP-ITC had the highest sensitivity (0.846), followed by M-CHAT (0.692) and ITSP (0.462). Conclusion Our results indicate a higher prevalence of autism in children with birth weights <1,500 g at 2 years of age compared to the general population prevalence. The ASD diagnosis was associated with shorter gestation times and longer hospital stays. Our findings support the simultaneous use of more than one screening tests in order to increase screening sensitivity. PMID:25484588

  8. Applicability of Screening Tests for Oxytetracycline in the Milk of Three Breeds of Goats.

    Science.gov (United States)

    Attaie, Rahmat; Bsharat, Mohammed; Mora-Gutierrez, Adela

    2016-06-01

    Antibiotics are widely used in animal husbandry, and the presence of antibiotic residues in milk is a health hazard. The objectives of this study were to determine residual amounts of oxytetracycline in the milk of three breeds of goats using high-pressure liquid chromatography (HPLC) analysis and screening tests. It was also essential to explore the safe withdrawal period of oxytetracycline in lactating goats and examine the applicability of Charm ROSA and SNAP screening tests. The qualitative results of these tests were compared with the quantitative results of the HPLC method. Fifteen milking does, five each from the Alpine, LaMancha, and Nubian breeds, were selected from the herd at Prairie View A&M University. Milk samples containing antibiotic residues were deproteinized by HCl and acetonitrile, and then oxytetracycline was extracted from the supernatant. The residues of oxytetracycline in goat's milk up to 110 h after injection were qualitatively detected using the Charm ROSA test. Similarly, the SNAP test detected the antibiotic residues in milk up to 110 h after treatment. The HPLC results indicated that oxytetracycline residues in milk from Alpine goats were below the tolerance level (300 ng/ml) 82 h after drug treatment (72 h for LaManchas, 58 h for Nubians); however, the results of the screening tests would indicate longer withdrawal periods for milk from the breeds of goats studied, which would result in economic losses to goat's milk producers. The results of this study also indicated that oxytetracycline was not stable in raw goat's milk at refrigeration temperature or during pasteurization and that the concentrations decreased significantly. Commercial goat's milk is usually exposed to several hours of refrigeration and then to pasteurization. The results of this study indicated that, if oxytetracycline was present in raw goat's milk, the concentration would decrease significantly before it was marketed.

  9. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  10. Cancer screening guidelines.

    Science.gov (United States)

    Zoorob, R; Anderson, R; Cefalu, C; Sidani, M

    2001-03-15

    Numerous medical organizations have developed cancer screening guidelines. Faced with the broad, and sometimes conflicting, range of recommendations for cancer screening, family physicians must determine the most reasonable and up-to-date method of screening. Major medical organizations have generally achieved consensus on screening guidelines for breast, cervical and colorectal cancer. For breast cancer screening in women ages 50 to 70, clinical breast examination and mammography are generally recommended every one or two years, depending on the medical organization. For cervical cancer screening, most organizations recommend a Papanicolaou test and pelvic examination at least every three years in patients between 20 and 65 years of age. Annual fecal occult blood testing along with flexible sigmoidoscopy at five-year to 10-year intervals is the standard recommendation for colorectal cancer screening in patients older than 50 years. Screening for prostate cancer remains a matter of debate. Some organizations recommend digital rectal examination and a serum prostate-specific antigen test for men older than 50 years, while others do not. In the absence of compelling evidence to indicate a high risk of endometrial cancer, lung cancer, oral cancer and ovarian cancer, almost no medical organizations have developed cancer screening guidelines for these types of cancer.

  11. Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

    International Nuclear Information System (INIS)

    Taxvig, Camilla; Olesen, Pelle Thonning; Nellemann, Christine

    2011-01-01

    Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.

  12. The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar

    2018-03-01

    This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility ( 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near

  13. Comparison of real-time PCR with disk diffusion, agar screen and E-test methods for detection of methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Shariati, Laleh; Validi, Majid; Tabatabaiefar, Mohammad Amin; Karimi, Ali; Nafisi, Mohammad Reza

    2010-12-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a nosocomial pathogen. Our main objective was to compare oxacillin disk test, oxacillin E-test, and oxacillin agar screen for detection of methicillin resistance in S. aureus, using real-time PCR for mecA as the "gold standard" comparison assay. 196 S. aureus isolates were identified out of 284 Staphylococcus isolates. These isolates were screened for MRSA with several methods: disk diffusion, agar screen (6.0 μg/ml), oxacillin E-test, and real-time PCR for detection of mecA gene. Of the 196 S. aureus isolates tested, 96 isolates (49%) were mecA-positive and 100 isolates (51%) mecA-negative. All methods tested had a statistically significant agreement with real-time PCR. E-test was 100% sensitive and specific for mecA presence. The sensitivity and specificity of oxacillin agar screen method were 98 and 99%, respectively and sensitivity and specificity of oxacillin disk diffusion method were 95 and 93%, respectively. In the present study, oxacillin E-test is proposed as the best phenotypic method. For economic reasons, the oxacillin agar screen method (6.0 μg/ml), which is suitable for the detection of MRSA, is recommended due to its accuracy and low cost.

  14. Evaluation of the King-Devick test as a concussion screening tool in high school football players.

    Science.gov (United States)

    Seidman, Daniel H; Burlingame, Jennifer; Yousif, Lina R; Donahue, Xinh P; Krier, Joshua; Rayes, Lydia J; Young, Rachel; Lilla, Muareen; Mazurek, Rochelle; Hittle, Kristie; McCloskey, Charles; Misra, Saroj; Shaw, Michael K

    2015-09-15

    Concussion is the most common type of traumatic brain injury, and results from impact or impulsive forces to the head, neck or face. Due to the variability and subtlety of symptoms, concussions may go unrecognized or be ignored, especially with the pressure placed on athletes to return to competition. The King-Devick (KD) test, an oculomotor test originally designed for reading evaluation, was recently validated as a concussion screening tool in collegiate athletes. A prospective study was performed using high school football players in an attempt to study the KD as a concussion screening tool in this younger population. 343 athletes from four local high school football teams were recruited to participate. These athletes were given baseline KD tests prior to competition. Individual demographic information was collected on the subjects. Standard team protocol was employed to determine if a concussion had occurred during competition. Immediately after diagnosis, the KD test was re-administered to the concussed athlete for comparison to baseline. Post-season testing was also performed in non-concussed individuals. Of the 343 athletes, nine were diagnosed with concussions. In all concussed players, cumulative read times for the KD test were significantly increased (phistory of concussion was the only demographic factor predictive of concussion in this cohort. The KD test is an accurate and easily administered sideline screening tool for concussion in adolescent football players. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Preliminary Tests Of The Decris-sc Ion Source

    CERN Document Server

    Efremov, A; Bechterev, V; Bogomolov, S L; Bondarenko, P G; Datskov, V I; Dmitriev, S; Drobin, V; Lebedev, A; Leporis, M; Malinowski, H; Nikiforov, A; Paschenko, S V; Seleznev, V; Shishov, Yu A; Smirnov, Yu; Tsvineva, G; Yakovlev, B; Yazvitsky, N Yu

    2004-01-01

    A new "liquid He-free" superconducting Electron Cyclotron Resonance Ion Source DECRIS-SC, to be used as injector for the IC-100 small cyclotron, has been designed by FLNR and LHE JINR. The main feature is that a compact refrigerator of Gifford-McMahon type is used to cool the solenoid coils. For the reason of very small cooling power at 4.2 K (about 1 W) our efforts were to optimize the magnetic structure and minimize an external heating of the coils. The maximum magnetic field strength is 3 T and 2 T in injection and extraction region respectively. For the radial plasma confinement a hexapole made of NdFeB permanent magnet is used. The source will be capable of ECR plasma heating using different frequencies (14 GHz or 18 GHz). To be able to deliver usable intensities of solids, the design is also allow axial access for evaporation oven and metal samples using the plasma sputtering technique. Very preliminary results of the source test are presented.

  16. Pilot Integration of HIV Screening and Healthcare Settings with Multi- Component Social Network and Partner Testing for HIV Detection.

    Science.gov (United States)

    Rentz, Michael F; Ruffner, Andrew H; Ancona, Rachel M; Hart, Kimberly W; Kues, John R; Barczak, Christopher M; Lindsell, Christopher J; Fichtenbaum, Carl J; Lyons, Michael S

    2017-11-23

    Healthcare settings screen broadly for HIV. Public health settings use social network and partner testing ("Transmission Network Targeting (TNT)") to select high-risk individuals based on their contacts. HIV screening and TNT systems are not integrated, and healthcare settings have not implemented TNT. The study aimed to evaluate pilot implementation of multi-component, multi-venue TNT in conjunction with HIV screening by a healthcare setting. Our urban, academic health center implemented a TNT program in collaboration with the local health department for five months during 2011. High-risk or HIV positive patients of the infectious diseases clinic and emergency department HIV screening program were recruited to access social and partner networks via compensated peer-referral, testing of companions present with them, and partner notification services. Contacts became the next-generation index cases in a snowball recruitment strategy. The pilot TNT program yielded 485 HIV tests for 482 individuals through eight generations of recruitment with five (1.0%; 95% CI = 0.4%, 2.3%) new diagnoses. Of these, 246 (51.0%; 95% CI = 46.6%, 55.5%) reported that they had not been tested for HIV within the last 12 months and 383 (79.5%; 95% CI = 75.7%, 82.9%) had not been tested by the existing ED screening program within the last five years. TNT complements population screening by more directly targeting high-risk individuals and by expanding the population receiving testing. Information from existing healthcare services could be used to seed TNT programs, or TNT could be implemented within healthcare settings. Research evaluating multi-component, multi-venue HIV detection is necessary to maximize complementary approaches while minimizing redundancy. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  18. Development and initial testing of a computer-based patient decision aid to promote colorectal cancer screening for primary care practice

    Directory of Open Access Journals (Sweden)

    Fowler Beth

    2005-11-01

    Full Text Available Abstract Background Although colorectal cancer screening is recommended by major policy-making organizations, rates of screening remain low. Our aim was to develop a patient-directed, computer-based decision aid about colorectal cancer screening and investigate whether it could increase patient interest in screening. Methods We used content from evidence-based literature reviews and our previous decision aid research to develop a prototype. We performed two rounds of usability testing with representative patients to revise the content and format. The final decision aid consisted of an introductory segment, four test-specific segments, and information to allow comparison of the tests across several key parameters. We then conducted a before-after uncontrolled trial of 80 patients 50–75 years old recruited from an academic internal medicine practice. Results Mean viewing time was 19 minutes. The decision aid improved patients' intent to ask providers for screening from a mean score of 2.8 (1 = not at all likely to ask, 4 = very likely to ask before viewing the decision aid to 3.2 afterwards (difference, 0.4; p Conclusion We conclude that a computer-based decision aid can increase patient intent to be screened and increase interest in screening. Practice Implications: This decision aid can be viewed by patients prior to provider appointments to increase motivation to be screened and to help them decide about which modality to use for screening. Further work is required to integrate the decision aid with other practice change strategies to raise screening rates to target levels.

  19. Nigerian Journal of Chemical Research Vol.12, 2007 Preliminary ...

    African Journals Online (AJOL)

    HP USER

    Preliminary Studies on the Phytochemical and Pharmacological Screening of Alchornea Cordifolia. M. O. Edema* and O. P. Osarumwense ... leaves extract used by local medicine practitioners for the treatment of ... plant in Africa and is used in the traditional medicine ... presence of alkaloids, cardiac glycosides, saponins,.

  20. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury.

    Science.gov (United States)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars L; Myklebust, Grethe; Kallemose, Thomas; Lauridsen, Hanne B; Hölmich, Per; Aagaard, Per; Zebis, Mette K

    2016-06-01

    Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. Sixty-two adolescent female elite football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored during three standardized screening tests - i.e. one-legged horizontal hop (OLH), drop vertical jump (DJ) and sidecutting (SC). Neuromuscular pre-activity was measured in the time interval 10ms prior to initial contact on a force plate. For neuromuscular hamstring muscle pre-activity, correlation analysis (Spearman correlation coefficient) showed low-to-moderate correlations between SC and 1) DJ (rs=0.34-0.36, Phamstring pre-activity share some common variance during the examined tests. However, a lack of strong correlation suggests that we cannot generalize one risk factor during one test to another test. The present data demonstrate that one-legged horizontal hop and drop vertical jump testing that are commonly used in the clinical setting does not resemble the specific neuromuscular activity patterns known to exist during sidecutting, a well known high risk movement for non-contact ACL injury. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Detection and identification of occult HBV in blood donors in Taiwan using a commercial, multiplex, multi-dye nucleic acid amplification technology screening test.

    Science.gov (United States)

    Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M

    2014-02-01

    The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.

  2. Preliminary Single-Phase Mixing Test using Wire Mesh System in a wire-wrapped 37-rod Bundle

    International Nuclear Information System (INIS)

    Bae, Hwang; Kim, Hyungmo; Lee, Dong Won; Choi, Hae Seob; Choi, Sun Rock; Chang, Seokkyu; Kim, Seok; Euh, Dongjin; Lee, Hyeongyeon

    2014-01-01

    In this paper, preliminary tests of the wire-mesh sensor are introduced before measuring of mixing coefficient in the wire-wrapped 37-pin fuel assembly for a sodium-cooled fast reactor. Through this preliminary test, it was confirmed that city water can be used as a tracer for demineralized water as a base. A simple test was performed to evaluate the characteristics of a wire mesh with of a short pipe shape. The conductivity of de-mineralized water and city water is linearly increased for the limited temperature ranges as the temperature is increased. The reliability of the wire mesh sensor was estimated based on the averages and standard deviations of the plane image using the cross points. A wire mesh sensor is suitable to apply to a single-phase flow measurement for a mixture with de-mineralized water and city water. A wire mesh sensor and system have been traditionally used to measure the void fraction of a two-phase flow field with gas and liquid. Recently, Ylonen et al. successfully designed and commissioned a measurement system for a single-phase flow using a wire mesh sensor

  3. Screening for Dementia in Older Adults: Comparison of Mini-Mental State Examination, Mini-Cog, Clock Drawing Test and AD8.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin

    2016-01-01

    This study was conducted to estimate screening performance of dementia screening tools including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) for older adults. 2015 participants aged 65 years or more in eastern China were enrolled. 4 screening tests were administered and scored by specifically trained psychiatrists. We used data from two-by-two tables to calculate the sensitivity, specificity, and positive and negative predictive values (PPV/NPV). Our study showed that dementia was highly prevalent among elderly in Zhejiang province. The Mini-Cog, with excellent screening characteristics and spending less time, could be considered to be used as a screening tool among communities to help to diagnose dementia early.

  4. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    Directory of Open Access Journals (Sweden)

    Espen Enerly

    Full Text Available Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP, 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1% hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  5. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    Science.gov (United States)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  6. Preliminary Design of the HiLumi-LHC Triplet Area Beam Screen

    CERN Document Server

    Kersevan, R; Kos, N

    2014-01-01

    The so-called beam screen (BS) is a proven solution for intercepting the thermal loads caused by the circulating beams in the cryogenically-cooled sections of the LHC and minimizing dynamic vacuum effects [1]. The new triplet area foreseen for the HiLumi-LHC (HL-LHC) machine upgrade [2] has the additional feature of needing internal tungsten shields to reduce the amount of collision debris which is deflected by the high-gradient triplet magnets towards the superconducting magnets' cold masses and coils. The very aggressive optics design, based on large beam separations, calls for a maximum of physical space to remain available to the counter rotating beams in the common BS. This places severe constraints to the fabrication and installation tolerances of the BS itself, in addition to affecting the design and routing of the cryogenic lines in the area. The latest version of the BS design will be shown and discussed, together with future plans for testing materials, fabrication procedures, and installation.

  7. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  8. LC-HRMS Metabolomics for Untargeted Diagnostic Screening in Clinical Laboratories: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Bertrand Rochat

    2018-06-01

    Full Text Available Today’s high-resolution mass spectrometers (HRMS allow bioanalysts to perform untargeted/global determinations that can reveal unexpected compounds or concentrations in a patient’s sample. This could be performed for preliminary diagnosis attempts when usual diagnostic processes and targeted determinations fail. We have evaluated an untargeted diagnostic screening (UDS procedure. UDS is a metabolome analysis that compares one sample (e.g., a patient with control samples (a healthy population. Using liquid chromatography (LC-HRMS full-scan analysis of human serum extracts and unsupervised data treatment, we have compared individual samples that were spiked with one xenobiotic or a higher level of one endogenous compound with control samples. After the use of different filters that drastically reduced the number of metabolites detected, the spiked compound was eventually revealed in each test sample and ranked. The proposed UDS procedure appears feasible and reliable to reveal unexpected xenobiotics (toxicology or higher concentrations of endogenous metabolites. HRMS-based untargeted approaches could be useful as preliminary diagnostic screening when canonical processes do not reveal disease etiology nor establish a clear diagnosis and could reduce misdiagnosis. On the other hand, the risk of overdiagnosis of this approach should be reduced with mandatory biomedical interpretation of the patient’s UDS results and with confirmatory targeted and quantitative determinations.

  9. Semantic Verbal Fluency test in dementia: Preliminary retrospective analysis

    Directory of Open Access Journals (Sweden)

    Marcos Lopes

    Full Text Available Abstract The Semantic Verbal Fluency (SVF test entails the generation of words from a given category within a pre-set time of 60 seconds. Objectives: To verify whether socio-demographic and clinical data of individuals with dementia correlate with the performance on the SVF test and to ascertain whether differences among the criteria of number of answers, clusters and data spread over the intervals, predict clinical results. Methods: This was a retrospective study of 49 charts of demented patients classified according to the Clinical Dementia Rating (CDR scale. We correlated education, age and gender, as well as CDR and Mini-Mental State Exam (MMSE scores with the number of answers, clustering and switching distributed over four 15-second intervals on the SVF test. Results: The correlation between number of answers and quartiles was weak (r=0.407, p=0.004; r=0.484, p<0.001 but correlation between the number of clusters and responses was strong (r=0.883, p<0.001. The number of items on the SVF was statistically significant with MMSE score (p=0.01 and there was a tendency for significance on the CDR (p=0.06. The results indicated little activity regarding what we propose to call cluster recalling in the two groups. Discussion: The SVF test, using number of items generated, was found to be more effective than classic screening tests in terms of speed and ease of application in patients with CDR 2 and 3.

  10. Primary care colorectal cancer screening correlates with breast cancer screening: implications for colorectal cancer screening improvement interventions.

    Science.gov (United States)

    Weiss, Jennifer M; Pandhi, Nancy; Kraft, Sally; Potvien, Aaron; Carayon, Pascale; Smith, Maureen A

    2018-04-25

    National colorectal cancer (CRC) screening rates have plateaued. To optimize interventions targeting those unscreened, a better understanding is needed of how this preventive service fits in with multiple preventive and chronic care needs managed by primary care providers (PCPs). This study examines whether PCP practices of other preventive and chronic care needs correlate with CRC screening. We performed a retrospective cohort study of 90 PCPs and 33,137 CRC screening-eligible patients. Five PCP quality metrics (breast cancer screening, cervical cancer screening, HgbA1c and LDL testing, and blood pressure control) were measured. A baseline correlation test was performed between these metrics and PCP CRC screening rates. Multivariable logistic regression with clustering at the clinic-level estimated odds ratios and 95% confidence intervals for these PCP quality metrics, patient and PCP characteristics, and their relationship to CRC screening. PCP CRC screening rates have a strong correlation with breast cancer screening rates (r = 0.7414, p < 0.001) and a weak correlation with the other quality metrics. In the final adjusted model, the only PCP quality metric that significantly predicted CRC screening was breast cancer screening (OR 1.25; 95% CI 1.11-1.42; p < 0.001). PCP CRC screening rates are highly concordant with breast cancer screening. CRC screening is weakly concordant with cervical cancer screening and chronic disease management metrics. Efforts targeting PCPs to increase CRC screening rates could be bundled with breast cancer screening improvement interventions to increase their impact and success.

  11. Telephone screening tests for functionally impaired hearing: current use in seven countries and development of a US version.

    Science.gov (United States)

    Watson, Charles S; Kidd, Gary R; Miller, James D; Smits, Cas; Humes, Larry E

    2012-01-01

    An estimated 36 million US citizens have impaired hearing, but nearly half of them have never had a hearing test. As noted by a recent National Institutes of Health/National Institute on Deafness and Other Communication Disorders (NIH/NIDCD) Working Group, "In the United States (in contrast to many other nations) there are no readily accessible low cost hearing screening programs…" (Donahue et al, 2010, p. 2). Since 2004, telephone administered screening tests utilizing three-digit sequences presented in noise have been developed, validated, and implemented in seven countries. Each of these tests has been based on a test protocol conceived by Smits and colleagues in The Netherlands. Investigators from Communication Disorders Technology, Inc., Indiana University, and VU University Medical Center of Amsterdam agreed to collaborate in the development and validation of a screening test for hearing impairment suitable for delivery over the telephone, for use in the United States. This test, utilizing spoken three-digit sequences (triplets), was to be based on the design of Smits and his colleagues. A version of the digits-in-noise test was developed utilizing digit triplets spoken in Middle American dialect. The stimuli were individually adjusted to speech-to-noise ratio (SNR) values yielding 50% correct identification, on the basis of data collected from a group of 10 young adult listeners with normal hearing. A final set of 64 homogeneous stimuli were selected from an original 160 recorded triplets. Each test consisted of a series of 40 triplets drawn at random, presented in a noise background. The SNR threshold for 50% correct identification of the triplets was determined by a one-down, one-up adaptive procedure. The test was implemented by telephone, and administered to listeners with varying levels of hearing impairment. The listeners were then evaluated with pure-tone tests and other audiometric measures as clinically appropriate. Ninety participants included 72

  12. Restriction of human papillomavirus DNA testing in primary cervical screening to women above age 30

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Njor, Sisse H; Lynge, Elsebeth

    2012-01-01

    Cervical screening with human papillomavirus (HPV) testing is less specific for high-grade cervical intraepithelial neoplasia (=CIN3) than cytology. The aim of this systematic review was to determine whether a restriction of HPV testing to women aged at least 30 years would eliminate the problem...

  13. Cost-effectiveness analysis of cervical cancer prevention based on a rapid human papillomavirus screening test in a high-risk region of China.

    Science.gov (United States)

    Levin, Carol E; Sellors, John; Shi, Ju-Fang; Ma, Li; Qiao, You-lin; Ortendahl, Jesse; O'Shea, Meredith K H; Goldie, Sue J

    2010-09-01

    This study assessed the cost-effectiveness of a new, rapid human papillomavirus (HPV)-DNA screening test for cervical cancer prevention in the high-risk region of Shanxi, China. Using micro-costing methods, we estimated the resources needed to implement preventive strategies using cervical cytology or HPV-DNA testing, including the Hybrid Capture 2 (hc2) test (QIAGEN Corp., Gaithersburg, MD) and the rapid HPV-DNA careHPV test (QIAGEN). Data were used in a previously published model and empirically calibrated to country-specific epidemiological data. Strategies differed by initial test, targeted age, frequency of screening, number of clinic visits required (1, 2 or 3) and service delivery setting (national, county and township levels). Outcomes included lifetime risk of cancer, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios (cost per YLS). For all screening frequencies, the most efficient strategy used 2-visit rapid HPV-DNA testing at the county level, including screening and diagnostics in the first visit, and treatment in the second visit. Screening at ages 35, 40 and 45 reduced cancer risk by 50% among women compliant with all 3 screening rounds, and was US$ 150 per YLS, compared with this same strategy applied twice per lifetime. This would be considered very cost-effective evaluated against China's per-capita gross domestic product (US$ 1,702). By enhancing the linkage between screening and treatment through a reduced number of visits, rapid HPV-DNA testing 3 times per lifetime is more effective than traditional cytology, and is likely to be cost-effective in high-risk regions of China.

  14. Gain versus loss-framed messaging and colorectal cancer screening among African Americans: A preliminary examination of perceived racism and culturally targeted dual messaging.

    Science.gov (United States)

    Lucas, Todd; Hayman, Lenwood W; Blessman, James E; Asabigi, Kanzoni; Novak, Julie M

    2016-05-01

    This preliminary study examined the effect of gain versus loss-framed messaging as well as culturally targeted personal prevention messaging on African Americans' receptivity to colorectal cancer (CRC) screening. This research also examined mechanistic functions of perceived racism in response to message framing. Community samples of African Americans (N = 132) and White Americans (N = 50) who were non-compliant with recommended CRC screening completed an online education module about CRC, and were either exposed to a gain-framed or loss-framed message about CRC screening. Half of African Americans were exposed to an additional and culturally targeted self-control message about personal prevention of CRC. Theory of planned behavior measures of attitudes, normative beliefs, perceived behavioural control, and intentions to obtain a CRC screen served as primary outcomes. The effect of messaging on perceived racism was also measured as an outcome. Consistent with prior research, White Americans were more receptive to CRC screening when exposed to a loss-framed message. However, African Americans were more receptive when exposed to a gain-framed message. The contrary effect of loss-framed messaging on receptivity to screening among African Americans was mediated by an increase in perceived racism. However, including an additional and culturally targeted prevention message mitigated the adverse effect of a loss-framed message. This study identifies an important potential cultural difference in the effect of message framing on illness screening among African Americans, while also suggesting a culturally relevant linking mechanism. This study also suggests the potential for simultaneously presented and culturally targeted messaging to alter the effects of gain and loss-framed messaging on African Americans. What is already known on this subject? African Americans are at an increased risk of both developing and dying from colorectal cancer (CRC). These disparities can be

  15. Cascade carrier testing after a child is diagnosed with cystic fibrosis through newborn screening: investigating why most relatives do not have testing.

    Science.gov (United States)

    McClaren, Belinda J; Aitken, Maryanne; Massie, John; Amor, David; Ukoumunne, Obioha C; Metcalfe, Sylvia A

    2013-07-01

    Newborn screening for cystic fibrosis is increasingly available, but cascade testing following the diagnosis in a child has received little attention. We previously reported low levels of cascade testing over time, and this study investigated motivators as well as barriers to testing. Parents were interviewed about communicating the genetic information and also asked to recruit their relatives to receive a specifically developed questionnaire. Thirty parents were interviewed and addresses of 284 relatives were provided; completed questionnaires were received from 225 (79%). A relative's relationship to the child, as well as knowledge, is associated with having had carrier testing. Relatives' reasons for testing included curiosity and wanting information for other relatives and for reproductive planning. Reasons for not testing were perceived irrelevance, lacking awareness, and viewing it as something to do in the future. Parents communicated the genetic information to relatives in various ways, which contributed to whether relatives accessed carrier testing. Newborn screening programs should provide support to parents to aid communication of genetic information to relatives. (Ir)relevance of testing is often linked to life stage; ongoing support and communication may allow relatives to learn of their risk and then seek testing, if they wish, at a time perceived to be most relevant to them.

  16. Incomplete follow-up of positive HPV tests: overview of randomised controlled trials on primary cervical screening

    DEFF Research Database (Denmark)

    Rebolj, M; Lynge, E

    2010-01-01

    with follow-up in HPV-positive women and relative >/=CIN3 detection was 0.48 (P=0.33).Conclusion:There is at present scant evidence to support the view that the measured sensitivity of HPV screening is a simple reflection of compliance with follow-up. Adjustment of measured cervical intraepithelial neoplasia......Background:It has been suggested that adjustment for incomplete compliance with follow-up in women with positive human papillomavirus (HPV) tests would be appropriate for estimating the true sensitivity of cervical screening with HPV testing. We assessed the compliance and its impact on >/=CIN3...

  17. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  18. Preliminary Screening Assessment of the Potential Impact of the Phosphate Fertilizer Industry on Wildlife

    Energy Technology Data Exchange (ETDEWEB)

    Vandenhove, Hildegarde; Sweeck, Lieve; Vives i Batlle, Jordi [SCK.CEN, Belgian Nuclear Research Centre, Boeretang 200, B-2400 Mol (Belgium)

    2014-07-01

    The activities of the phosphate industry may lead to enhanced levels of naturally occurring radioactivity in terrestrial and freshwater ecosystems. We here perform a preliminary environmental risk assessment (ERA) of the activities of the phosphate industry (phosphate ore mining, phosphate fertilizer factories, phosphate export platforms). We evaluated the environmental impact of 5 phosphate fertilizer plants (located in Belgium, Spain, Syria, Egypt, Brazil) and one phosphate-mine and phosphate-export platforms in the harbour(both located in Syria). These sites were selected because of the enhanced concentrations of naturally occurring radionuclides in the surrounding environments. The ERICA non-human biota assessment tool was used to predict radiation dose rates to the reference organisms and associated risks. Reference organisms were those assigned as default by the ERICA Tool. Potential impact is expressed as a risk quotient (RQ) based on a radiation screening value of 10 μGy h{sup -1}. If RQ ≤ 1, the environment is unlikely at risk and further radiological assessment is deemed not to be required. For all the cases assessed, RQ exceeded 1 for at least one of the reference organisms. {sup 226}Ra or {sup 210}Po were generally the highest contributors to the dose. The aquatic ecosystems in the vicinity of the phosphate fertilizer plants in Tessenderlo (Belgium), Huelva (Spain), Goias (Brazil) and the terrestrial environment around the phosphate mine in Palmyra (Syria) are the ecosystems predicted most at risk. (authors)

  19. Instrument to screen cases of pervasive developmental disorder: a preliminary indication of validity Instrumento para rastreamento dos casos de transtorno invasivo do desenvolvimento: estudo preliminar de validação

    Directory of Open Access Journals (Sweden)

    Fábio Pinato Sato

    2009-03-01

    Full Text Available OBJECTIVE: To translate into Portuguese, back-translate, culturally adapt and validate a screening instrument for pervasive developmental disorder, the Autism Screening Questionnaire, for use in Brazil. METHOD: A sample of 120 patients was selected based on three groups of 40: patients with a clinical diagnosis of pervasive developmental disorder, Down syndrome, or other psychiatric disorders. The self-administered questionnaire was applied to the patients' legal guardians. Psychometric measures of the final version of the translated questionnaire were tested. RESULTS: The score of 15 had sensitivity of 92.5% and specificity of 95.5% as a cut-off point for the diagnosis of pervasive developmental disorder. Internal validity for a total of 40 questions was 0.895 for alpha and 0.896 for KR-20, ranging from 0.6 to 0.8 for both coefficients. Test and retest reliability values showed strong agreement for most questions. CONCLUSIONS: The final version of this instrument, translated into Portuguese and adapted to the Brazilian culture, had satisfactory measurement properties, suggesting preliminary validation proprieties. It was an easy-to-apply, useful tool for the diagnostic screening of individuals with pervasive developmental disorder.OBJETIVO: Tradução, retro-versão, adaptação cultural e validação do Autism Screening Questionnaire para a língua portuguesa e para o seu uso no Brasil. MÉTODO: Foi selecionada uma amostra inicial de 120 pacientes, encaminhados de duas clínicas privadas e uma pública, divida em três grupos de 40 pacientes distintos: pacientes com diagnóstico clínico de transtornos globais do desenvolvimento ou transtornos invasivos do desenvolvimento; de síndrome de Down e de outros transtornos psiquiátricos. O questionário foi aplicado aos responsáveis legais dos pacientes seguindo os padrões de um questionário auto-aplicável. As medidas psicométricas do questionário traduzido, na sua versão final, foram

  20. Astrophysical black holes in screened modified gravity

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Anne-Christine; Jha, Rahul; Muir, Jessica [Department of Applied Mathematics and Theoretical Physics, Centre for Mathematical Sciences, University of Cambridge, Wilberforce Road, Cambridge, CB3 0WA (United Kingdom); Gregory, Ruth, E-mail: acd@damtp.cam.ac.uk, E-mail: r.a.w.gregory@durham.ac.uk, E-mail: r.jha@damtp.cam.ac.uk, E-mail: jlmuir@umich.edu [Centre for Particle Theory, South Road, Durham, DH1 3LE (United Kingdom)

    2014-08-01

    Chameleon, environmentally dependent dilaton, and symmetron gravity are three models of modified gravity in which the effects of the additional scalar degree of freedom are screened in dense environments. They have been extensively studied in laboratory, cosmological, and astrophysical contexts. In this paper, we present a preliminary investigation into whether additional constraints can be provided by studying these scalar fields around black holes. By looking at the properties of a static, spherically symmetric black hole, we find that the presence of a non-uniform matter distribution induces a non-constant scalar profile in chameleon and dilaton, but not necessarily symmetron gravity. An order of magnitude estimate shows that the effects of these profiles on in-falling test particles will be sub-leading compared to gravitational waves and hence observationally challenging to detect.

  1. Astrophysical black holes in screened modified gravity

    International Nuclear Information System (INIS)

    Davis, Anne-Christine; Jha, Rahul; Muir, Jessica; Gregory, Ruth

    2014-01-01

    Chameleon, environmentally dependent dilaton, and symmetron gravity are three models of modified gravity in which the effects of the additional scalar degree of freedom are screened in dense environments. They have been extensively studied in laboratory, cosmological, and astrophysical contexts. In this paper, we present a preliminary investigation into whether additional constraints can be provided by studying these scalar fields around black holes. By looking at the properties of a static, spherically symmetric black hole, we find that the presence of a non-uniform matter distribution induces a non-constant scalar profile in chameleon and dilaton, but not necessarily symmetron gravity. An order of magnitude estimate shows that the effects of these profiles on in-falling test particles will be sub-leading compared to gravitational waves and hence observationally challenging to detect

  2. The Addenbrooke's Cognitive Examination Revised (ACE-R): a brief cognitive test battery for dementia screening.

    Science.gov (United States)

    Mioshi, Eneida; Dawson, Kate; Mitchell, Joanna; Arnold, Robert; Hodges, John R

    2006-11-01

    There is a clear need for brief, but sensitive and specific, cognitive screening instruments as evidenced by the popularity of the Addenbrooke's Cognitive Examination (ACE). We aimed to validate an improved revision (the ACE-R) which incorporates five sub-domain scores (orientation/attention, memory, verbal fluency, language and visuo-spatial). Standard tests for evaluating dementia screening tests were applied. A total of 241 subjects participated in this study (Alzheimer's disease=67, frontotemporal dementia=55, dementia of Lewy Bodies=20; mild cognitive impairment-MCI=36; controls=63). Reliability of the ACE-R was very good (alpha coefficient=0.8). Correlation with the Clinical Dementia Scale was significant (r=-0.321, pcognitive dysfunction. Copyright (c) 2006 John Wiley & Sons, Ltd.

  3. Discordant human T-lymphotropic virus screening with Western blot confirmation: evaluation of the dual-test algorithm for US blood donations.

    Science.gov (United States)

    Stramer, Susan L; Townsend, Rebecca L; Foster, Gregory A; Johnson, Ramona; Weixlmann, Barbara; Dodd, Roger Y

    2018-03-01

    Human T-lymphotropic virus (HTLV) blood donation screening has used a dual-testing algorithm beginning with either a chemiluminescent immunoassay or enzyme-linked immunosorbent screening assay (ELISA). Before the availability of a licensed HTLV supplemental assay, repeat-reactive (RR) samples on a first assay (Assay 1) were retested with a second screening assay (Assay 2). Donors with RR results by Assay 2 were deferred from blood donation and further tested using an unlicensed supplemental test to confirm reactivity while nonreactive (NR) donors remained eligible for donation until RR on a subsequent donation. This "dual-test" algorithm was replaced in May 2016 with the requirement that all RRs by Assay 1 be further tested by a licensed HTLV supplemental test (Western blot [WB]). In this study, we have requalified the dual-test algorithm using the available licensed HTLV WB. We tested 100 randomly selected HTLV RRs on screening Assay 1 (Abbott PRISM chemiluminescent immunoassay) but NR on screening Assay 2 (Avioq ELISA) by a Food and Drug Administration-licensed WB (MP Biomedicals) to ensure that no confirmed positives were among those that were RR by Assay 1 but NR by Assay 2. Of the 100 samples evaluated, 79 of 100 were WB seronegative, 21 of 100 indeterminate, and 0 of 100 seropositive. Of the 79 of 100 seronegative specimens, 73 of 79 did not express any bands on WB. We demonstrated that none of the 100 samples RR on Assay 1 but NR on Assay 2 were confirmed positive. This algorithm prevents such donors from requiring further testing and from being deferred. © 2018 AABB.

  4. Real-time screening tests for functional alignment of the trunk and lower extremities in adolescent – a systematic review

    DEFF Research Database (Denmark)

    Junge, Tina; Wedderkopp, N; Juul-Kristensen, B

    mechanisms resulting in ACL injuries (Hewett, 2010). Prevention may therefore depend on identifying these potentially injury risk factors. Screening tools must thus include patterns of typical movements in sport and leisure time activities, consisting of high-load and multi-directional tests, focusing...... on functional alignment. In large epidemiological studies these tests must only require a minimum of time and technical equipment. Objective The purpose of the study was to accomplish a systematic review of screening tests for identification of adolescents at increased risk of knee injuries, focusing...... of knee alignment, there is a further need to evaluate reliability and validity of real-time functional alignment tests, before the can be used as screening tools for prevention of knee injuries among adolescents. Still the next step in this systematic review is to evaluate the quality and feasibility...

  5. In vitro preliminary cytotoxicity testing of vegetal extracts, using colorimetric methods

    Directory of Open Access Journals (Sweden)

    Claudia Patricia Cordero Camacho

    2002-01-01

    Full Text Available To advance in the study of the Colombian vegetal biodiversity, considered as a potential source of pharmacologically active products, the establishment of biological activity evaluation systems is necessary, which allow the detection of active products against pathologies with high social and economical impact, such as cancer. This work describes the implementation of a preliminary in vitro methodology for the determination of potential anticancer activity in vegetal extracts, by cytotoxicity testing upon human tumor cell lines, measuring the cellular mass indirectly with the colorimetric assays of MTT (methyl tetrazolium tiazole reduction and SRB (sulforhodamine Bstaining. HT-29, MCF-7, SiHa and HEp-2 cell lines cultures were adapted, MTT concentration, cellular density and treatment period parameters for the cytotoxicity assay were selected. Cell lines sensitivity to the chemotherapeutic agent Doxorubicin HCl was determined. Colombian vegetal species extracts cytotoxicity was tested and usefulness of the assay as a tool to bioguide the search of active products was evidenced.

  6. In vitro preliminary cytotoxicity testing of vegetal extracts, using colorimetric methods

    Directory of Open Access Journals (Sweden)

    Claudia Patricia Cordero Camacho

    2011-12-01

    Full Text Available To advance in the study of the Colombian vegetal biodiversity, considered as a potential source of pharmacologically active products, the establishment of biological activity evaluation systems is necessary, which allow the detection of active products against pathologies with high social and economical impact, such as cancer. This work describes the implementation of a preliminary in vitro methodology for the determination of potential anticancer activity in vegetal extracts, by cytotoxicity testing upon human tumor cell lines, measuring the cellular mass indirectly with the colorimetric assays of MTT (methyl tetrazolium tiazole reduction and SRB (sulforhodamine Bstaining. HT-29, MCF-7, SiHa and HEp-2 cell lines cultures were adapted, MTT concentration, cellular density and treatment period parameters for the cytotoxicity assay were selected. Cell lines sensitivity to the chemotherapeutic agent Doxorubicin HCl was determined. Colombian vegetal species extracts cytotoxicity was tested and usefulness of the assay as a tool to bioguide the search of active products was evidenced.

  7. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients

    DEFF Research Database (Denmark)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte

    2017-01-01

    Background: Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential...... in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted...... skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who...

  8. A tailored approach to BRAF and MLH1 methylation testing in a universal screening program for Lynch syndrome.

    Science.gov (United States)

    Adar, Tomer; Rodgers, Linda H; Shannon, Kristen M; Yoshida, Makoto; Ma, Tianle; Mattia, Anthony; Lauwers, Gregory Y; Iafrate, Anthony J; Chung, Daniel C

    2017-03-01

    To determine the correlation between BRAF genotype and MLH1 promoter methylation in a screening program for Lynch syndrome (LS), a universal screening program for LS was established in two medical centers. Tumors with abnormal MLH1 staining were evaluated for both BRAF V600E genotype and MLH1 promoter methylation. Tumors positive for both were considered sporadic, and genetic testing was recommended for all others. A total 1011 colorectal cancer cases were screened for Lynch syndrome, and 148 (14.6%) exhibited absent MLH1 immunostaining. Both BRAF and MLH1 methylation testing were completed in 126 cases. Concordant results (both positive or both negative) were obtained in 86 (68.3%) and 16 (12.7%) cases, respectively, with 81% concordance overall. The positive and negative predictive values for a BRAF mutation in predicting MLH1 promoter methylation were 98.9% and 41%, respectively, and the negative predictive value fell to 15% in patients ≥70 years old. Using BRAF genotyping as a sole test to evaluate cases with absent MLH1 staining would have increased referral rates for genetic testing by 2.3-fold compared with MLH1 methylation testing alone (31% vs 13.5%, respectively, PMLH1 methylation testing for BRAF wild-type cases only would significantly decrease the number of methylation assays performed and reduce the referral rate for genetic testing to 12.7%. A BRAF mutation has an excellent positive predictive value but poor negative predictive value in predicting MLH1 promoter methylation. A hybrid use of these tests may reduce the number of low-risk patients referred to genetic counseling and facilitate wider implementation of Lynch syndrome screening programs.

  9. Terrestrial Eco-Toxicological Tests as Screening Tool to Assess Soil Contamination in Krompachy Area

    Science.gov (United States)

    Ol'ga, Šestinová; Findoráková, Lenka; Hančuľák, Jozef; Fedorová, Erika; Tomislav, Špaldon

    2016-10-01

    In this study, we present screening tool of heavy metal inputs to agricultural and permanent grass vegetation of the soils in Krompachy. This study is devoted to Ecotoxicity tests, Terrestrial Plant Test (modification of OECD 208, Phytotoxkit microbiotest on Sinapis Alba) and chronic tests of Earthworm (Dendrobaena veneta, modification of OECD Guidelines for the testing of chemicals 317, Bioaccumulation in Terrestrial Oligochaetes) as practical and sensitive screening method for assessing the effects of heavy metals in Krompachy soils. The total Cu, Zn, As, Pb and Hg concentrations and eco-toxicological tests of soils from the Krompachy area were determined of 4 sampling sites in 2015. An influence of the sampling sites distance from the copper smeltery on the absolutely concentrations of metals were recorded for copper, lead, zinc, arsenic and mercury. The highest concentrations of these metals were detected on the sampling sites up to 3 km from the copper smeltery. The samples of soil were used to assess of phytotoxic effect. Total mortality was established at earthworms using chronic toxicity test after 7 exposure days. The results of our study confirmed that no mortality was observed in any of the study soils. Based on the phytotoxicity testing, phytotoxic effects of the metals contaminated soils from the samples 3KR (7-9) S.alba seeds was observed.

  10. Screening tests are not enough to detect hemineglect Testes de triagem não são suficientes para diagnosticar heminegligência

    Directory of Open Access Journals (Sweden)

    Manuel Alvim Leite Lopes

    2007-12-01

    Full Text Available OBJECTIVE: To verify the sensitivity of the conventional subtests of the Behavioral Inattention Test (BIT in the diagnosis of hemineglect after stroke. METHOD: One hundred and two patients with cerebral infarct or hemorrhage were prospectively evaluated. In 22, hemineglect was diagnosed using standard BIT criteria. The frequency of hemineglect using 6 commonly used screening subtests of this battery was assessed. RESULTS: Hemineglect would not be recognized in 10 patients if they were only screened using the line crossing test; this would be the case in 2 patients with the letter cancellation test; and in 4 patient with the line bisection test. Three patients would not be diagnosed even if both line crossing and line bisection tests were used. CONCLUSION: Hemineglect may not be recognized with single screening tests commonly used. The use of a standard battery is recommended to improve diagnostic sensitivity in individuals with various subtypes of hemineglect.OBJETIVO: Verificar a sensibilidade dos subtestes convencionais da Behavioral Inattention Test (BIT no diagnóstico da heminegligência após o acidente vascular cerebral (AVC. MÉTODO: Foram avaliados prospectivamente 102 pacientes com AVC. Em 22 casos heminegligência foi diagnosticada através do BIT. A freqüência de diagnóstico correto utilizando os 6 subtestes específicos desta bateria foi analisada. RESULTADOS: 10 pacientes não seriam diagnosticados como heminegligentes se fossem avaliados apenas com o " line crossing" , 2 se o teste de triagem escolhido fosse o " letter cancellation" , e 4 se utilizássemos apenas o " line bisection" . Além disso, 3 pacientes não teriam recebido o diagnóstico correto mesmo utilizando dois testes usuais de triagem - " line crossing" e " line bisection" . CONCLUSÃO: O uso de testes isolados de triagem pode falhar em diagnosticar heminegligência após o AVC. O uso de uma bateria formal de avaliação é necessário para identificar indiv

  11. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  12. Preliminary performance test of control rod position indicator for ballscrew type CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. H.; Hu, H.; Lee, J. S.; Kim, J. I.

    2003-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The prototype of control rod position indicator having the high performance for the ballscrew type CEDM was developed on the basis of RSPT technology identified through the survey. The characteristics of control rod position indicator was defined and documented through design procedure and preliminary performance test

  13. Molecular HIV screening.

    Science.gov (United States)

    Bourlet, Thomas; Memmi, Meriam; Saoudin, Henia; Pozzetto, Bruno

    2013-09-01

    Nuclear acid testing is more and more used for the diagnosis of infectious diseases. This paper focuses on the use of molecular tools for HIV screening. The term 'screening' will be used under the meaning of first-line HIV molecular techniques performed on a routine basis, which excludes HIV molecular tests designed to confirm or infirm a newly discovered HIV-seropositive patient or other molecular tests performed for the follow-up of HIV-infected patients. The following items are developed successively: i) presentation of the variety of molecular tools used for molecular HIV screening, ii) use of HIV molecular tools for the screening of blood products, iii) use of HIV molecular tools for the screening of organs and tissue from human origin, iv) use of HIV molecular tools in medically assisted procreation and v) use of HIV molecular tools in neonates from HIV-infected mothers.

  14. Reflooding Experimental On Beta Test Loop : The Characterisation And Preliminary Experiment

    International Nuclear Information System (INIS)

    Khairul, H.; Antariksawan, Anhar R.; Sumamo, Edy; Kiswanta; Giarno; Joko, P.; H, Ismu

    2001-01-01

    The characterisation and preliminary experiment of reflooding had been conducted. The characteristics of main system and component had been identified completely. From these characteristics the experiment condition was set up : heated rod voltage was 20 volt, frequency,of pump was 19 Hz, flow rate was 1 m3/h. The first of experiment did not show the phenomena of rewetting. Possibly because the heated rod temperature was too low. For the second experiment, the voltage of heated rod was increased to 22 Volt and the flow rate was decreased. The result was that the nucleation boiling on the surfaced of heated rod, was observed during the water re flooded the test section

  15. Evaluation of high pressure Freon decontamination. I. Preliminary tests

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    High-pressure Freon blasting techniques are being evaluated for applications involving the removal of non-adherent radioactive particulate contamination at SRP. Very little waste is generated by this technique because the used Freon can be easily distilled and reused. One of the principle advantages of this technique is that decontaminated electrical equipment can be returned to service immediately without drying, unlike high-pressure water blasting techniques. Preliminary scoutin tests evaluating high-pressure Freon blasting for decontamination at SRP were carried out at Quadrex Co., Oak Ridge, TN, October 12 and 13. DWPF-type contamination (raw sludge plus volatiles) and separations area-type contamination (diluted boiling point (47.6 0 C) allow it to rapidly separate from higher boiling contaminants via distillation with filtration to remove particulate material, and distillation with condensation, the solvent may be recovered for indefinite reuse while reducing the radioactive waste to a minimum. 3 references, 5 figures, 6 tables

  16. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  17. Skin Cancer Screening

    Science.gov (United States)

    ... Genetics of Skin Cancer Skin Cancer Screening Research Skin Cancer Screening (PDQ®)–Patient Version What is screening? ... These are called diagnostic tests . General Information About Skin Cancer Key Points Skin cancer is a disease ...

  18. Preliminary results for HIP bonding Ta to W targets for the materials test station

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, David E [Los Alamos National Laboratory; Maloy, Stuart A [Los Alamos National Laboratory

    2009-01-01

    Tungsten targets for the Materials Test Station (MTS) were clad with thin tantalum cover plates and a tantalum frame using hot isostatic pressing (HIP). A preliminary HIP parameter study showed good bonding and intimate mechanical contact for Ta cover plate thicknesses of 0.25 mm (0.010 inch) and 0.38 mm (0.015 inch). HIP temperatures of full HIP runs were 1500 C (2732 F). HIP pressure was 203 MPa (30 ksi).

  19. Preliminary tests of the electrostatic plasma accelerator

    Science.gov (United States)

    Aston, G.; Acker, T.

    1990-01-01

    This report describes the results of a program to verify an electrostatic plasma acceleration concept and to identify those parameters most important in optimizing an Electrostatic Plasma Accelerator (EPA) thruster based upon this thrust mechanism. Preliminary performance measurements of thrust, specific impulse and efficiency were obtained using a unique plasma exhaust momentum probe. Reliable EPA thruster operation was achieved using one power supply.

  20. Isolation and Preliminary Screening of a Weissella confusa Strain from Giant Panda (Ailuropoda melanoleuca).

    Science.gov (United States)

    Xiong, Lvchen; Ni, Xueqin; Niu, Lili; Zhou, Yi; Wang, Qiang; Khalique, Abdul; Liu, Qian; Zeng, Yan; Shu, Gang; Pan, Kangcheng; Jing, Bo; Zeng, Dong

    2018-04-13

    Weissella confusa has recently received attention for its probiotic potential. Some W. confusa and Weissella cibaria strains isolated from fermented foods show favorable probiotic effects. However, the probiotic properties of W. confusa isolated from giant panda remain unreported to date. Thus, this study isolated a W. confusa strain from giant panda feces and then investigated its characteristics and probiotic properties. A lactic acid bacteria strain was isolated from giant panda fecal samples. The isolated strain was screened by in vitro probiotic property tests, including in vitro antimicrobial test, antioxidant test, surface hydrophobicity, and stress resistance. On the basis of biochemical identification and 16S rDNA sequencing, the W. confusa strain was identified as BSP201703. This Weissella confusa strain can survive at pH 2 and 0.3% (w/v) concentration of bile salt environment and inhibit common intestinal pathogens. It also possesses an in vitro antioxidant capacity, a high auto-aggregation ability, and a high surface hydrophobicity. BSP201703 might serve as a probiotic to giant pandas.

  1. Current status of VEGA program and a preliminary test with cesium iodide

    International Nuclear Information System (INIS)

    Hidaka, A.; Nakamura, T.; Kudo, T.; Hayashida, R.; Nakamura, J.; Otomo, T.; Uetsuka, H.

    2000-01-01

    The VEGA program has been performed at JAERI to clarify the mechanism of FP release from irradiated PWR/BWR fuels including MOX fuel and to improve predictability of the source term. The principal purposes are to investigate the release of actinides and FPs including non-volatile radionuclides from irradiated fuel at 3000degC under high pressure condition up to 1.0 MPa. The short-life radionuclides will be accumulated by re-irradiation of test fuel just before the experiment using the JAERI's research reactor such as JRR-3 or NSRR. The test facility was installed into the beta/gamma concrete No.5 cell at RFEF and completed in February, 1999. Before the first VEGA-1 test in September, 1999, a preliminary test using a cold simulant, cesium iodide (CsI) was performed to confirm the fundamental capabilities of the test facility. The test results showed that the trapping efficiency of the aerosol filters is about 98%. The amount of CsI which arrived at the downstream pipe of the filters was quite small while a small amount of I 2 gas which can pass through the filters was condensed just before the cold condenser as expected in the design. (author)

  2. [Comparison of screening performance between primary high-risk HPV screening and high-risk HPV screening plus liquid-based cytology cotesting in diagnosis of cervical precancerous or cancerous lesions].

    Science.gov (United States)

    Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H

    2018-05-06

    Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, PHPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, PHPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, PHPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.

  3. ERG and GRG review of the draft of ''preliminary test plan for in situ testing from an exploratory shaft in salt - October 1983''

    International Nuclear Information System (INIS)

    Kalia, H.N.

    1986-03-01

    The Engineering Review Group (ERG) and Geologic Review Group (GRG) were established by the Office of Nuclear Waste Isolation (ONWI) to help evaluate engineering- and geologic-related issues in the US Department of Energy's nuclear waste repository program. The January 1984 meeting of the ERG and GRG reviewed the In Situ Test Plan (ISTP) titled ''Preliminary Test Plan for In Situ Testing From an Exploratory Shaft in Salt - October 1983.'' This report documents the ERG's and GRG's comments and recommendations on this subject and the ONWI responses to the specific points raised by the ERG and GRG. 6 refs., 2 figs., 1 tab

  4. The attitudes of Dutch fertility specialists towards the addition of genetic testing in screening of tubal factor infertility.

    Science.gov (United States)

    Malogajski, Jelena; Jansen, Marleen E; Ouburg, Sander; Ambrosino, Elena; Terwee, Caroline B; Morré, Servaas A

    2017-06-01

    This study aims to identify elements perceived by Dutch fertility specialists as barriers and facilitators for the introduction of genetic testing, and their attitudes towards the use of genetic information. The genetic test would be implemented in routine screening for tubal pathology and identifies SNPs relevant for the immune response causing tubal pathology. Experienced reproductive specialists working in Dutch Academic Hospitals were interviewed. Based on the results of four interviews a questionnaire was developed and used to survey medical doctors in six out of eight Dutch Academic hospitals. 60.4% (n=91) stated that the addition of genetic markers to the Chlamydia trachomatis antibody test (CAT) in screening for tubal pathology would increase screening accuracy. 68.2% (n=90) agreed they would require additional training on clinical genetics. Clinical utility (91.2%, n=91) and cost-effectiveness (95.6%, n=91) were recognized by the respondents as important factors in gaining support for the new screening strategy. In summary, respondents showed a positive attitude towards the implementation of a genetic test combined with CAT for tubal factor infertility (TFI) screening. To gain their support the majority of respondents agreed that clinical utility, specifically cost-effectiveness, is an important factor. Comprehensive research about economic implications and utility regarding the introduction of genomic markers should be the next step in the implementation strategy. Furthermore, education and training would need to be developed and offered to fertility care professionals about genetic markers, their interpretation, and implications for clinical decision-making. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Screening for Cancer

    Science.gov (United States)

    Cancer screening is checking for cancer in people who don't have symptoms. Screening tests can help doctors find and treat several types of cancer early, but cancer screening can have harms as well as benefits.

  6. Screening for Dyslexia in French-Speaking University Students: An Evaluation of the Detection Accuracy of the Alouette Test.

    Science.gov (United States)

    Cavalli, Eddy; Colé, Pascale; Leloup, Gilles; Poracchia-George, Florence; Sprenger-Charolles, Liliane; El Ahmadi, Abdessadek

    Developmental dyslexia is a lifelong impairment affecting 5% to 10% of the population. In French-speaking countries, although a number of standardized tests for dyslexia in children are available, tools suitable to screen for dyslexia in adults are lacking. In this study, we administered the Alouette reading test to a normative sample of 164 French university students without dyslexia and a validation sample of 83 students with dyslexia. The Alouette reading test is designed to screen for dyslexia in children, since it taps skills that are typically deficient in dyslexia (i.e., phonological skills). However, the test's psychometric properties have not previously been available, and it is not standardized for adults. The results showed that, on the Alouette test, dyslexic readers were impaired on measures of accuracy, speed, and efficiency (accuracy/reading time). We also found significant correlations between the Alouette reading efficiency and phonological efficiency scores. Finally, in terms of the Alouette test, speed-accuracy trade-offs were found in both groups, and optimal cutoff scores were determined with receiver operator characteristic curves analysis, yielding excellent discriminatory power, with 83.1% sensitivity and 100% specificity for reading efficiency. Thus, this study supports the Alouette test as a sensitive and specific screening tool for adults with dyslexia.

  7. Screening for colorectal cancer

    DEFF Research Database (Denmark)

    Nielsen, Hans J.; Jakobsen, Karen V.; Christensen, Ib J.

    2011-01-01

    Emerging results indicate that screening improves survival of patients with colorectal cancer. Therefore, screening programs are already implemented or are being considered for implementation in Asia, Europe and North America. At present, a great variety of screening methods are available including...... into improvements of screening for colorectal cancer includes blood-based biological markers, such as proteins, DNA and RNA in combination with various demographically and clinically parameters into a "risk assessment evaluation" (RAE) test. It is assumed that such a test may lead to higher acceptance among...... procedures for colorectal cancer. Therefore, results of present research, validating RAE tests, are awaited with interest....

  8. Noninvasive prenatal testing in routine clinical practice--an audit of NIPT and combined first-trimester screening in an unselected Australian population.

    Science.gov (United States)

    McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus

    2016-02-01

    There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  9. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Queral, V., E-mail: vicentemanuel.queral@ciemat.es [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Urbon, J. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Garcia, A.; Cuarental, I.; Mota, F. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Micciche, G. [CR ENEA Brasimone, I-40035 Camugnano (BO) (Italy); Ibarra, A. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Rapisarda, D. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Casal, N. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain)

    2011-10-15

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  10. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    International Nuclear Information System (INIS)

    Queral, V.; Urbon, J.; Garcia, A.; Cuarental, I.; Mota, F.; Micciche, G.; Ibarra, A.; Rapisarda, D.; Casal, N.

    2011-01-01

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  11. Toxicology screen

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003578.htm Toxicology screen To use the sharing features on this page, please enable JavaScript. A toxicology screen refers to various tests that determine the ...

  12. Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  13. Preliminary Screening Analysis for the Environmental Risk Evaluation System: Task 2.1.1: Evaluating Effects of Stressors – Fiscal Year 2010 Progress Report: Environmental Effects of Marine and Hydrokinetic Energy

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Richard M.; Copping, Andrea E.; Van Cleve, Frances B.

    2010-11-15

    Possible environmental effects of marine and hydrokinetic (MHK) energy development are not well understood, and yet regulatory agencies are required to make decisions in spite of substantial uncertainty about environmental impacts and their long-term effects. An understanding of risk associated with likely interactions between MHK installations and aquatic receptors, including animals, habitats, and ecosystems, can help reduce the level of uncertainty and focus regulatory actions and scientific studies on interactions of most concern. As a first step in developing the Pacific Northwest National Laboratory (PNNL) Environmental Risk Evaluation System (ERES), PNNL scientists conducted a preliminary risk screening analysis on three initial MHK cases - a tidal project in Puget Sound using Open Hydro turbines, a wave project off the coast of Oregon using Ocean Power Technologies point attenuator buoys, and a riverine current project in the Mississippi River using Free Flow turbines. Through an iterative process, the screening analysis revealed that top-tier stressors in all three cases were the effects of the dynamic physical presence of the device (e.g., strike), accidents, and effects of the static physical presence of the device (e.g., habitat alteration). Receptor interactions with these stressors at the four highest tiers of risk were dominated by marine mammals (cetaceans and pinnipeds) and birds (diving and non-diving); only the riverine case (Free Flow) included different receptors in the third tier (fish) and the fourth tier (benthic invertebrates). Although this screening analysis provides a preliminary analysis of vulnerability of environmental receptors to stressors associated with MHK installations, probability analysis, especially of risk associated with chemical toxicity and accidents such as oil spills or lost gear, will be necessary to further understand high-priority risks. Subject matter expert review of this process and results is required and is

  14. Responses to procedural information about colorectal cancer screening using faecal occult blood testing: the role of consideration of future consequences

    Science.gov (United States)

    von Wagner, Christian; Good, Anna; Smith, Samuel G.; Wardle, Jane

    2011-01-01

    Abstract Background  Colorectal cancer (CRC) screening participation is low despite its effectiveness in reducing CRC mortality. Identifying benefits and barriers requires consideration of specific characteristics of screening modalities. Aims and Research Questions  To monitor the impact of providing information about CRC screening via faecal occult blood testing (FOBt) on intentions to participate. To investigate moderation by individual differences in consideration of future consequences (CFC). Design, setting and participants  A total of 211 healthy adults (aged 45–59) with no experience of CRC screening were presented with eight consecutive statements about FOBt‐based screening in a web survey. Participants completed measures of i) intention (after each statement), ii) CFC and iii) the importance of screening practicalities (e.g. unpleasantness of completing the test) and benefits (e.g. early detection of cancer). Results  An 8 (information) × 2 (CFC) mixed ancova showed that intentions varied across the eight statements. (P < 0.001): increasing after information about FOBt being completed at home (P < 0.001) before subsequently decreasing after information about the requirement to collect faecal samples (P < 0.001) in a plastic tub (P < 0.01) on three occasions (P < 0.01) with the low CFC group generally being less inclined to complete the test (P < 0.01). Two between‐group anovas demonstrated that the low CFC group attributed greater importance to practicalities of screening than the high CFC group while the opposite was found for the importance of benefits (both P’s < 0.001). Conclusion  Deconstructing FOBt‐based screening pointed to specific benefits and barriers which can advance research into public preferences of screening and educational materials. PMID:21501350

  15. The performance of the SEPT9 gene methylation assay and a comparison with other CRC screening tests: A meta-analysis.

    Science.gov (United States)

    Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin

    2017-06-08

    The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.

  16. Combining pharmacophore fingerprints and PLS-discriminant analysis for virtual screening and SAR elucidation

    DEFF Research Database (Denmark)

    Askjær, Sune; Langgård, Morten

    2008-01-01

    The criterion of success for the initial stages of a ligand-based drug-discovery project is dual. First, a set of suitable lead compounds has to be identified. Second, a level of a preliminary structure-activity relationship (SAR) of the identified ligands has to be established in order to guide ...... by the protein-binding site known from X-ray complexes. The result of this analysis assists in explaining the efficiency of 2D pharmacophore fingerprints as descriptors in virtual screening....... the lead optimization toward a final drug candidate. This paper presents a combined approach to solving these two problems of ligand-based virtual screening and elucidation of SAR based on interplay between pharmacophore fingerprints and interpretation of PLS-discriminant analysis (PLS-DA) models....... The virtual screening capability of the PLS-DA method is compared to group fusion maximum similarity searching in a test using four graph-based pharmacophore fingerprints over a range of 10 diverse targets. The PLS-DA method was generally found to do better than the Smax method. The GpiDAPH3 and PCH...

  17. Preliminary phytochemical screening of roots and aerial parts of leptadenia pyrotechnica

    International Nuclear Information System (INIS)

    Munazir, M.; Qureshi, R.; Munir, M.

    2015-01-01

    Leptadenia pyrotechnica (Forssk.) Decne is a medicinal plant that is native to hot deserts of Pakistan. This plant is sporadically known with reference to bioactivity including phytochemical screening especially from Pakistan. The present study was designed to screen out four major groups of phytochemicals such as alkaloids, flavonoids, saponins and tannins from eight solvents based roots and aerial parts extracts viz., hexane, chloroform, acetone, ethyl acetate, butanol, ethanol, methanol and water of the selected plant. The qualitative screening showed the presence of all major groups of phytochemicals in both plant parts extracts in which methanolic ones were the most efficient that extracted all the selected classes of phytochemicals. Quantitative screening revealed various concentrations of selected phytochemicals in both plant parts. The alkaloid contents were 3.267±0.643and 3±0.6 in roots and aerial parts respectively (p>0.05). The total flavonoid content was 76.867±2.266 and 139.448±8.677 QE/100g in roots and aerial parts respectively. In the case of total saponin contents, the proportions were 0.34±0.013% and 0.4 0.010% in roots and aerial parts respectively, whereas; total tannin contents were 62.713±4.841 and154.961±5.853 mg of TAE/100g of extract in roots and aerial parts, respectively. This study will serve as a benchmark for further pharmacological studies on the said plant that may be harnessed for drug development in the future. (author)

  18. Preliminary Design Progress of the HCCR TBM for ITER testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Won; Park, Sung Dae; Kim, Dong Jun; Jin, Hyung Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, Mu-Young [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Korea has designed a helium cooled ceramic reflector (HCCR) test blanket module (TBM) including the TBM-shield, which is called the TBM-set, to be tested in ITER, a Nuclear Facility INB-174. Through the conceptual design review (CDR), its design integrity was successfully demonstrated at the conceptual design level at various loads. After CD approval, preliminary design (PD) was started and the progress is introduced in the present study. After PD review and approval, final design and then fabrication will be started. The main purpose of PD is to design the TBM-set according to the fabrication aspect and more detailed design for interfaces with ITER machine, such as installed TBM port plug and frame. With these considering, PD of TBM-set was started. PD for HCCR TBM has been performed (so far v0.24) from the CD model. FW, BZ, SW, TES/NAS, BM, and connecting support design were performed through the analyses, if necessary. The manufacturability was the main concern for PD model development. Thermal hydraulic analysis will be performed to evaluate the temperature and pressure drop in TBM-set. The structural integrity of TBM-set will be confirmed with combined various loads condition.

  19. Screening women for cervical cancer carcinoma with a HPV mRNA test: first results from the Venice pilot program.

    Science.gov (United States)

    Maggino, Tiziano; Sciarrone, Rocco; Murer, Bruno; Dei Rossi, Maria Rosa; Fedato, Chiara; Maran, Michela; Lorio, Melania; Soldà, Marika; Zago, Fiorella; Giorgi Rossi, Paolo; Zorzi, Manuel

    2016-08-23

    HPV DNA-based screening is more effective than a Pap test in preventing cervical cancer, but the test is less specific. New HPV tests have been proposed for primary screening. The HPV mRNA test showed a similar or slightly lower sensitivity than the HPV DNA tests but with a higher specificity. We report the results of an organised HPV mRNA-based screening pilot program in Venice, Italy. From October 2011 to May 2014, women aged 25-64 years were invited to undergo a HPV mRNA test (Aptima). Those testing positive underwent cytological triage. Women with positive cytology were referred to colposcopy, whereas those with negative cytology were referred to repeat the HPV mRNA test 1 year later. The results of the HPV mRNA test program were compared with both the local historical cytology-based program and with four neighbouring DNA HPV-based pilot projects. Overall, 23 211 women underwent a HPV mRNA test. The age-standardised positivity rate was 7.0%, higher than in HPV DNA programs (6.8%; relative rate (RR) 1.11, 95% confidence interval (CI) 1.05-1.17). The total colposcopy referral was 5.1%, double than with cytology (2.6%; RR 2.02, 95% CI 1.82-2.25) but similar to the HPV DNA programs (4.8%; RR 1.02; 95% CI 0.96-1.08). The cervical intraepithelial neoplasia grade 2+ detection rate with HPV mRNA was greater than in the HPV DNA programs at baseline (RR 1.50; 95% CI 1.19-1.88) and not significantly lower at the 1-year repeat (RR 0.70; 95% CI 0.40-1.16). The overall RR was 1.29 (95% CI 1.05-1.59), which was much higher than with cytology (detection rate 5.5‰ vs 2.1‰; RR 2.50, 95% CI 1.76-3.62). A screening programme based on the HPV mRNA obtained results similar to those observed with the HPV DNA test. In routine screening programmes, even a limited increase in HPV prevalence may conceal the advantage represented by the higher specificity of HPV mRNA.

  20. Verification testing of the compression performance of the HEVC screen content coding extensions

    Science.gov (United States)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  1. Low-dose CT: new tool for screening lung cancer?

    International Nuclear Information System (INIS)

    Diederich, S.; Wormanns, D.; Heindel, W.

    2001-01-01

    Lung cancer is the leading cause of death from malignant tumours as it is very common and has a poor prognosis at advanced tumour stages. Prognosis could be improved by treatment at early stages. As these stages are usually asymptomatic, a diagnostic test that would allow detection of early tumour stages in a population at risk could potentially reduce mortality from lung cancer. Previous approaches using chest radiography and sputum cytology in smokers have been disappointing. Fluorescent bronchoscopy and molecular markers are not yet applicable in clinical routine. Because of its high sensitivity for small pulmonary nodules, which are the most common manifestation of early lung cancer, CT appears suitable as a screening test. Low-dose examination parameters can and should be used for this purpose. From clinical practice it is well known that chest CT often demonstrates small pulmonary nodules, which do not represent lung cancer. Therefore, non-invasive diagnostic algorithms are required to avoid unnecessary biopsies in benign lesions. In preliminary studies of low-dose CT using algorithms based on size and density of detected nodules a large proportion of asymptomatic lung cancers and a large proportion of early, resectable tumour stages were found with a small proportion of invasive procedures for benign nodules. Before this technology can be recommended for broad application, however, further information is required regarding appropriate inclusion criteria (smoking habits, age groups) and screening intervals. Most importantly, further data are required to clarify whether lung cancer screening using low-dose CT can actually reduce mortality from lung cancer. (orig.)

  2. Central auditory processing disorder (CAPD tests in a school-age hearing screening programme – analysis of 76,429 children

    Directory of Open Access Journals (Sweden)

    Piotr H. Skarzynski

    2015-02-01

    Full Text Available [b]Introduction and objective[/b]. Hearing disorders among school-age children are a current concern. Continuing studies have been performed in Poland since 2008, and on 2 December 2011 the EU Council adopted Conclusions on the Early Detection and Treatment of Communication Disorders in Children, Including the Use of e-Health Tools and innovative Solutions. The discussion now focuses not only on the efficacy of hearing screening programmes in schoolchildren, but what should be its general aim and what tests it should include? This paper makes the case that it is important to include central auditory processing disorder (CAPD tests. One such test is the dichotic digits test (DDT. The aim of the presented study was to evaluate the usefulness of the DDT in detecting central hearing disorders in school-age children. [b]Materials and methods[/b]. During hearing screening programmes conducted in Poland in 2008–2010, exactly 235,664 children (7–12-years-old were screened in 9,325 schools. Of this number, 7,642 were examined using the DDT test for CAPD. Screening programmes were conducted using the Sense Examination Platform. [b]Results.[/b] With the cut-off criterion set at the 5th percentile, results for the DDT applied in a divided attention mode were 11.4% positive for 7-year-olds and 11.3% for 12-year-olds. In the focused attention mode, the comparable result for 12-year-olds was 9.7%. There was a clear right ear advantage. In children with positive DDT results, a higher incidence of other disorders, such as dyslexia, was observed. [b]Conclusions[/b]. A test for CAPD should be included in the hearing screening of school-age children. The results of this study form the basis for developing Polish standards in this area.

  3. A first approach to a neuropsychological screening tool using eye-tracking for bedside cognitive testing based on the Edinburgh Cognitive and Behavioural ALS Screen.

    Science.gov (United States)

    Keller, Jürgen; Krimly, Amon; Bauer, Lisa; Schulenburg, Sarah; Böhm, Sarah; Aho-Özhan, Helena E A; Uttner, Ingo; Gorges, Martin; Kassubek, Jan; Pinkhardt, Elmar H; Abrahams, Sharon; Ludolph, Albert C; Lulé, Dorothée

    2017-08-01

    Reliable assessment of cognitive functions is a challenging task in amyotrophic lateral sclerosis (ALS) patients unable to speak and write. We therefore present an eye-tracking based neuropsychological screening tool based on the Edinburgh Cognitive and Behavioural ALS Screen (ECAS), a standard screening tool for cognitive deficits in ALS. In total, 46 ALS patients and 50 healthy controls matched for age, gender and education were tested with an oculomotor based and a standard paper-and-pencil version of the ECAS. Significant correlation between both versions was observed for ALS patients and healthy controls in the ECAS total score and in all of its ALS-specific domains (all r > 0.3; all p ALS patients and healthy controls in the ECAS total score (p ALS patients who are unable to speak or write.

  4. Method for screening the Nevada Test Site and contiguous areas for nuclear waste repository locations

    International Nuclear Information System (INIS)

    Sinnock, S.; Fernandez, J.A.; Neal, J.T.; Stephens, H.P.; Hartway, B.L.; Los Alamos Technical Associates, Inc., NM)

    1982-01-01

    This paper outlines the general concepts of a technical method for systematic screening of the Nevada Test Site (NTS), Nye County, Nevada, for potentially suitable nuclear waste repository locations. After a general discussion of the organization and the purpose of the current screening activity, the paper addresses the steps of the screening method. These steps include: hierarchically organizing technical objectives for repository performance (an objectives tree); identifying and mapping pertinent physical characteristics of a site and its setting (physical attributes); relating the physical conditions to the objectives (favorability curves); identifying alternative locations and numerically evaluating their relative merits; investigating the effects of subjective judgments on the evaluations (sensitivity analyses); documenting the assumptions, logic, and results of the method. 19 references, 10 figures

  5. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  6. Preliminary Flight Results of the Microelectronics and Photonics Test Bed: NASA DR1773 Fiber Optic Data Bus Experiment

    Science.gov (United States)

    Jackson, George L.; LaBel, Kenneth A.; Marshall, Cheryl; Barth, Janet; Seidleck, Christina; Marshall, Paul

    1998-01-01

    NASA Goddard Spare Flight Center's (GSFC) Dual Rate 1773 (DR1773) Experiment on the Microelectronic and Photonic Test Bed (MPTB) has provided valuable information on the performance of the AS 1773 fiber optic data bus in the space radiation environment. Correlation of preliminary experiment data to ground based radiation test results show the AS 1773 bus is employable in future spacecraft applications requiring radiation tolerant communication links.

  7. [Historical Development of the Wool and Colour Plate Tests for Screening for Colour Vision Deficiencies in German Speaking Countries].

    Science.gov (United States)

    Kuchenbecker, J

    2017-07-01

    Colour vision is a complex visual function that can be affected by congenital and/or acquired disorders. The frequency of congenital colour vision deficiencies has been investigated in rail and navy staff since the 1870s. Various test methods have been developed. Wool tests, flor contrast tests and colour plate tests have been used. A published colour plate test, based on Stilling's pseudo-isochromatic plates in combination with a flor contrast test, has been a common screening method for colour vision testing in German-speaking countries. This test is intended to detect congenital and acquired colour vision deficiencies in a simple and safe manner. More modern options, such as Internet and tablet PC have technical limitations, but will increasingly be used for screening for colour vision deficiencies. Georg Thieme Verlag KG Stuttgart · New York.

  8. Implementation of a Computerized Screening Inventory: Improved Usability Through Iterative Testing and Modification.

    Science.gov (United States)

    Boudreaux, Edwin D; Fischer, Andrew Christopher; Haskins, Brianna Lyn; Saeed Zafar, Zubair; Chen, Guanling; Chinai, Sneha A

    2016-03-09

    The administration of health screeners in a hospital setting has traditionally required (1) clinicians to ask questions and log answers, which can be time consuming and susceptible to error, or (2) patients to complete paper-and-pencil surveys, which require third-party entry of information into the electronic health record and can be vulnerable to error and misinterpretation. A highly promising method that avoids these limitations and bypasses third-party interpretation is direct entry via a computerized inventory. To (1) computerize medical and behavioral health screening for use in general medical settings, (2) optimize patient acceptability and feasibility through iterative usability testing and modification cycles, and (3) examine how age relates to usability. A computerized version of 15 screeners, including behavioral health screeners recommended by a National Institutes of Health Office of Behavioral and Social Sciences Research collaborative workgroup, was subjected to systematic usability testing and iterative modification. Consecutive adult, English-speaking patients seeking treatment in an urban emergency department were enrolled. Acceptability was defined as (1) the percentage of eligible patients who agreed to take the assessment (initiation rate) and (2) average satisfaction with the assessment (satisfaction rate). Feasibility was defined as the percentage of the screening items completed by those who initiated the assessment (completion rate). Chi-square tests, analyses of variance, and Pearson correlations were used to detect whether improvements in initiation, satisfaction, and completion rates were seen over time and to examine the relation between age and outcomes. Of 2157 eligible patients approached, 1280 agreed to complete the screening (initiation rate=59.34%). Statistically significant increases were observed over time in satisfaction (F3,1061=3.35, P=.019) and completion rates (F3,1276=25.44, PUsability testing revealed several critical

  9. Evaluation of three rapid oral fluid test devices on the screening of multiple drugs of abuse including ketamine.

    Science.gov (United States)

    Tang, Magdalene H Y; Ching, C K; Poon, Simon; Chan, Suzanne S S; Ng, W Y; Lam, M; Wong, C K; Pao, Ronnie; Lau, Angus; Mak, Tony W L

    2018-05-01

    Rapid oral fluid testing (ROFT) devices have been extensively evaluated for their ability to detect common drugs of abuse; however, the performance of such devices on simultaneous screening for ketamine has been scarcely investigated. The present study evaluated three ROFT devices (DrugWipe ® 6S, Ora-Check ® and SalivaScreen ® ) on the detection of ketamine, opiates, methamphetamine, cannabis, cocaine and MDMA. A liquid chromatography tandem mass spectrometry (LCMS) assay was firstly established and validated for confirmation analysis of the six types of drugs and/or their metabolites. In the field test, the three ROFT devices were tested on subjects recruited from substance abuse clinics/rehabilitation centre. Oral fluid was also collected using Quantisal ® for confirmation analysis. A total of 549 samples were collected in the study. LCMS analysis on 491 samples revealed the following drugs: codeine (55%), morphine (49%), heroin (40%), methamphetamine (35%), THC (8%), ketamine (4%) and cocaine (2%). No MDMA-positive cases were observed. Results showed that the overall specificity and accuracy were satisfactory and met the DRUID standard of >80% for all 3 devices. Ora-Check ® had poor sensitivities (ketamine 36%, methamphetamine 63%, opiates 53%, cocaine 60%, THC 0%). DrugWipe ® 6S showed good sensitivities in the methamphetamine (83%) and opiates (93%) tests but performed relatively poorly for ketamine (41%), cocaine (43%) and THC (22%). SalivaScreen ® also demonstrated good sensitivities in the methamphetamine (83%) and opiates (100%) tests, and had the highest sensitivity for ketamine (76%) and cocaine (71%); however, it failed to detect any of the 28 THC-positive cases. The test completion rate (proportion of tests completed with quality control passed) were: 52% (Ora-Check ® ), 78% (SalivaScreen ® ) and 99% (DrugWipe ® 6S). Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Do recommended doses of glyphosate-based herbicides affect soil invertebrates? Field and laboratory screening tests to risk assessment.

    Science.gov (United States)

    Niemeyer, Júlia Carina; de Santo, Fernanda Benedet; Guerra, Naiara; Ricardo Filho, Altair Maçaneiro; Pech, Tatiani Maria

    2018-05-01

    Despite glyphosate-based herbicides are widely used in agriculture, forestry and gardens, little is known about its effects on non-target organisms. The present work evaluated the ecotoxicity of four formulated products (Roundup ® Original, Trop ® , Zapp ® Qi 620 and Crucial ® ) on soil invertebrates. Screening ecotoxicity tests were carried out with soil and oat straw collected in a field experiment, besides laboratory-spiked soils. Screening tests included avoidance behaviour of earthworms (Eisenia andrei), collembolans (Folsomia candida) and isopods (Porcellio dilatatus) in single and multispecies tests; reproduction of collembolans (F. candida), and bait lamina in field. Non-avoidance behaviour was observed in standard tests (earthworms) in soil, neither in multispecies tests (earthworm + isopods) using oat straw, while for collembolans it occurred for the product Zapp ® Qi 620 even at the recommended dose. Reproduction of F. candida was not impaired even at high doses in laboratory-spiked soils. Feeding activity on bait lamina test was impaired in treatment corresponding to the red label product, Crucial ® . Results showed the relevance of bait lamina test on screening the impact of herbicides in the field. The findings highlight the importance of considering different formulations for the same active ingredient in risk assessment of pesticides. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. A comparison of face to face and group education on informed choice and decisional conflict of pregnant women about screening tests of fetal abnormalities

    Science.gov (United States)

    Kordi, Masoumeh; Riyazi, Sahar; Lotfalizade, Marziyeh; Shakeri, Mohammad Taghi; Suny, Hoseyn Jafari

    2018-01-01

    BACKGROUND AND GOAL: Screening of fetal anomalies is assumed as a necessary measurement in antenatal cares. The screening plans aim at empowerment of individuals to make the informed choice. This study was conducted in order to compare the effect of group and face-to-face education and decisional conflicts among the pregnant females regarding screening of fetal abnormalities. METHODS: This study of the clinical trial was carried out on 240 pregnant women at education course were held in two weekly sessions for intervention groups during two consecutive weeks, and the usual care was conducted for the control group. The rate of informed choice and decisional conflict was measured in pregnant women before education and also at weeks 20–22 of pregnancy in three groups. The data analysis was executed using SPSS statistical software (version 16), and statistical tests were implemented including Chi-square test, Kruskal–Wallis test, Wilcoxon test, Mann–Whitney U-test, one-way analysis of variance test, and Tukey's range test. The P education group, 64 members (80%) in group education class, and 20 persons (25%) in control group had the informed choice regarding screening tests, but there was no statistically significant difference between two individual and group education classes. Similarly, during the postintervention phase, there was a statistically significant difference in mean score of decisional conflict scale among pregnant women regarding screening tests in three groups (P = 0.001). DISCUSSION AND CONCLUSION: With respect to effectiveness of group and face-to-face education methods in increasing the informed choice and reduced decisional conflict in pregnant women regarding screening tests, each of these education methods may be employed according to the clinical environment conditions and requirement to encourage the women for conducting the screening tests. PMID:29417066

  12. Six years of vision screening tests in pre-school children in kindergartens of Wroclaw

    Science.gov (United States)

    Szmigiel, Marta; Geniusz, Malwina; Szmigiel, Ireneusz

    2017-09-01

    Detection of vision defects of a child without professional knowledge is not easy. Very often, the parents of a small child does not know that their child sees incorrect. Also the youngster, not knowing any other way of seeing, does not know that it is not the best. While the vision of a small child is not yet fully formed, it is worth checking them very early. Defects detected early gives opportunity for the correction of anomalies, which might give the effect of the normal development of vision. According to the indications, the American Optometric Association (AOA) control eye examination should be performed between the ages of 6 months to 3 years, before going to school and then every two years. Members of SPIE Student Chapter, in cooperation with the Visual Optics Group working on the Department of Optics and Photonics (Faculty of Fundamental Problems, Wroclaw University of Science and Technology) for 6 years offer selected kindergartens of Wroclaw participation in project "Screening vision tests in pre-school children". Depending on the number of involved members of the student chapter and willing to cooperate students of Ophthalmology and Optometry, vision screening test was carried out in up to eight kindergartens every year. The basic purpose of screening vision test is to detect visual defects to start the correction so early in life as possible, while increasing the efficiency of the child's visual potential. The surrounding community is in fact more than enough examples of late diagnose vision problems, which resulted in lack of opportunity or treatment failure

  13. Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening

    NARCIS (Netherlands)

    Vernooij-van Langen, Annette; Dompeling, Edward; Yntema, Jan-Bart; Arets, HGM; Tiddens, Harm; Loeber, Gerard; Dankert-Roelse, Jeannette

    After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99 %. The Nanoduct sweat test system is easier to perform and

  14. Red Blood Cell Antibody Screen: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/redbloodcellantibodyscreen.html Red Blood Cell Antibody Screen To use the sharing features on this page, please enable JavaScript. What is an RBC Antibody Screen? An RBC (red blood cell) antibody screen ...

  15. Performance of Small Bore 60NiTi Hybrid Ball Bearings: Preliminary Life Test Results

    Science.gov (United States)

    Dellacorte, Christopher; Howard, S. Adam

    2016-01-01

    Small bore (R8 size) hybrid ball bearings made with 60NiTi races and silicon nitride balls are under development for highly corrosive aerospace applications that are also exposed to heavy static (shock) loads. The target application is the vacuum pump used inside the wastewater recycling system on the International Space Station. To verify bearing longevity, life tests are run at 2000rpm for time periods up to 5000 hours. Accelerometers with data tracking are used to monitor operation and the bearings are disassembled and inspected at intervals to assess wear. Preliminary tests show that bearings made from 60NiTi are feasible for this aerospace and potentially other industrial applications that must endure similar operating environments.

  16. Preliminary report on the development of some indices of relative nutritive value (RNV) of cereal and legume samples, applicable in the early generations of selection

    International Nuclear Information System (INIS)

    Kaul, A.K.; Niemann, E.G.

    1975-01-01

    Rapid screening methods for biuret nitrogen determination and fluorometric lysine estimation are described. While the biuret method has been found to be suitable for early generation screening for peptide nitrogen determination, fluorescence estimation of dansylated grain meal could be taken as a good index of available lysine in cereal and legume samples. The necessity of rapid and inexpensive tests for the determination of Relative Nutritive Value (RNV) in the advance generations of screening, is discussed. Preliminary data available on two such tests, utilizing protozoan Tetrahymena pyriformis W. and flour beetle Tribolium confusum Duval, indicated promise. Both techniques were tried on different cereal and legume samples. The relative lethality of beetle larvae and their nitrogen retention were taken as indices of RNV in legumes. Larval Nitrogen Retention Index (LNRI) of cereal samples was found to be dependent both on nitrogen content and on protein quality. It was concluded that both these organisms need to be further investigated for their potential as test animals for RNV determination in the advance segregating populations. (author)

  17. Evaluating the feasibility of integrating salivary testing for congenital CMV into the Newborn Hearing Screening Programme in the UK.

    Science.gov (United States)

    Kadambari, Seilesh; Luck, Suzanne; Davis, Adrian; Walter, Simone; Agrup, Charlotte; Atkinson, Claire; Stimson, Laura; Williams, Eleri; Berrington, Janet; Griffiths, Paul; Sharland, Mike

    2015-08-01

    Congenital cytomegalovirus (cCMV) accounts for 20% of all childhood sensorineural hearing loss (SNHL) but is not routinely tested for at birth. Valganciclovir has been shown to prevent hearing deterioration and improve neurocognitive outcomes if started in the first month of life. This study aimed to assess the feasibility of integrating testing for cCMV using salivary swabs into the Newborn Hearing Screening Programme (NHSP). Parents of newborns newborn hearing screen for further audiological testing, were approached by hearing screeners to obtain a saliva sample for CMV DNA polymerase chain reaction (PCR). Eighty percent (203/255) of newborns who were eligible had a saliva swab taken by the hearing screener. Over 99% of results were delivered within the first month of life. Two newborns were identified with cCMV and both seen on day 10 of life by the paediatric specialist. All saliva samples tested delivered a result using real-time PCR. It is feasible for hearing screeners to obtain saliva swabs to test for CMV DNA using real-time PCR in newborns referred after their initial hearing screen. Rapid diagnostic testing for cCMV needs a more detailed clinical and cost-effectiveness analysis.

  18. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury

    DEFF Research Database (Denmark)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars Louis

    2016-01-01

    phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. METHODS: Sixty-two adolescent female elite......BACKGROUND: Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular...... football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored...

  19. Cervical human papilloma virus (HPV) DNA primary screening test: Results of a population-based screening programme in central Italy.

    Science.gov (United States)

    Passamonti, Basilio; Gustinucci, Daniela; Giorgi Rossi, Paolo; Cesarini, Elena; Bulletti, Simonetta; Carlani, Angela; Martinelli, Nadia; Broccolini, Massimo; D'Angelo, Valentina; D'Amico, Maria Rosaria; Di Dato, Eugenio; Galeazzi, Paola; Malaspina, Morena; Spita, Nicoletta; Tintori, Beatrice; Giaimo, Maria Donata

    2017-09-01

    Objective To present the results of the first and second round human papilloma virus (HPV)-based screening programme in the Umbria region after three years. Methods From August 2010 to November 2011, the entire female population aged 35-64 in a local health district was invited for HPV testing (HPV-DNA cobas4800 on a liquid-based cytology sample). HPV-negative women were re-invited after three years. For HPV-positive women, a slide was prepared and interpreted. Positive cytologies were referred to colposcopy; negatives were referred to repeat HPV after one year. If HPV was persistently positive, women were referred to colposcopy; if negative, to normal screening. Indicators of the first and second round are compared with those of cytology screening in the same area in the preceding three years. Results Participation was 56.5%, the same as cytology (56.6%). HPV-positivity was 6.4% (396/6272), cytology triage positivity was 35.6%; 251 cytology negative women were referred to one-year HPV retesting, 84.1% complied, and 55.5% were positive. Total colposcopy referral was 4.1%, and for cytology 1%. The detection rate for cervical intraepithelial neoplasia grade 2 or more severe was 10‰, compared with 3.7‰ using cytology. After three years, HPV-positivity was 3.4% (129/3831), overall colposcopy referral was 2.3% (most at one-year follow-up), and detection rate was 0.5/1000. Conclusions The first round detection rate was more than twice that of cytology screening, while colposcopy referral increased fourfold. At the second round, the detection rate decreased dramatically, showing that longer interval and more conservative protocols are needed.

  20. Long-term performance of colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Hassan, Cesare; Capodaglio, Giulia; Fedato, Chiara; Montaguti, Adriana; Turrin, Anna; Rosano, Alberto; Monetti, Daniele; Stocco, Carmen; Baracco, Susanna; Russo, Francesca; Repici, Alessandro; Rugge, Massimo

    2017-11-03

    The long-term performance of colorectal cancer (CRC) screening programmes based on a 2-year faecal immunochemical test (FIT) is still unclear. In a sample of 50 to 69-year-olds repeatedly screened with the FIT (OC-Hemodia latex agglutination test; cut-off: 20 µg haemoglobin/g faeces), we examined: (1) the FIT positivity rate, the CRC and advanced adenoma detection rate and the FIT's positive predictive value (PPV) for advanced neoplasia, at each round of screening and (2) the cumulative CRC and advanced adenoma detection rate after five rounds of FIT. Over 12 years (2002-2014), 123 347 individuals were administered the FIT up to six times, and 781 CRCs and 4713 advanced adenomas were diagnosed. The CRC and advanced adenoma detection rates declined substantially from the first to the third (rate ratio (RR) 0.25, 95% CI 0.20 to 0.32) and second (RR 0.51, 95% CI 0.47 to 0.56) rounds, respectively, and then remained stable. The PPV for advanced neoplasia dropped by 18% in the second round (RR 0.82, 95% CI 0.77 to 0.89), with no further reduction thereafter due to a concomitant decline in the FIT positivity rate (RR first to sixth rounds: 0.56, 95% CI 0.53 to 0.60).The cumulative CRC and advanced adenoma detection rates over five consecutive rounds were 8.5‰ (95% CI 7.8 to 9.2), and 58.9‰ (95% CI 56.9 to 61.0), respectively. Repeated FIT significantly reduces the burden of colorectal disease while facilitating an efficient use of colonoscopy resources. The cumulative detection rate after five rounds of FIT is similar to primary screening with colonoscopy, supporting the need to account for the cumulative sensitivity of repeated FITs when evaluating the test's efficacy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.