WorldWideScience

Sample records for preliminary imaging studies

  1. TREE STEM RECONSTRUCTION USING VERTICAL FISHEYE IMAGES: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    A. Berveglieri

    2016-06-01

    Full Text Available A preliminary study was conducted to assess a tree stem reconstruction technique with panoramic images taken with fisheye lenses. The concept is similar to the Structure from Motion (SfM technique, but the acquisition and data preparation rely on fisheye cameras to generate a vertical image sequence with height variations of the camera station. Each vertical image is rectified to four vertical planes, producing horizontal lateral views. The stems in the lateral view are rectified to the same scale in the image sequence to facilitate image matching. Using bundle adjustment, the stems are reconstructed, enabling later measurement and extraction of several attributes. The 3D reconstruction was performed with the proposed technique and compared with SfM. The preliminary results showed that the stems were correctly reconstructed by using the lateral virtual images generated from the vertical fisheye images and with the advantage of using fewer images and taken from one single station.

  2. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    International Nuclear Information System (INIS)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C.

    2001-01-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  3. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  4. Correlation of early-phase 18F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    International Nuclear Information System (INIS)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju; Huang, Chin-Chang; Hsu, Wen-Chun; Yen, Tzu-Chen; Kung, Mei-Ping

    2012-01-01

    18 F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R 1 ) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R 1 images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R 1 and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R 1 images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R 1 . A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R 1 and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  5. Correlation of early-phase {sup 18}F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); Huang, Chin-Chang; Hsu, Wen-Chun [Chang Gung Memorial Hospital, Department of Neurology, Taipei (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Kung, Mei-Ping [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2012-04-15

    {sup 18}F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R{sub 1}) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R{sub 1} images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R{sub 1} and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R{sub 1} images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R{sub 1}. A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R{sub 1} and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  6. Magnetic resonance imaging of the brain in neonates. Preliminary results

    International Nuclear Information System (INIS)

    Dumoulin, M.; Legrand, M.; Gremillet, C.; Lecouffe, P.; Rousseau, J.; Pruvo, J.P.; Marchandise, X.

    1991-01-01

    The place of neonatal cerebral MRI and its specific contribution compared with conventional imaging techniques were evaluated in 36 patients. The difficulties specific to the patient population studied met during this preliminary period are described, with their local solutions. A preliminary evaluation of the diagnostic and prognostic value of MRI according to the disease state and gestational age is presented. The specific contribution of MRI compared with transfontanellar ultrasonography and CT scan is discussed [fr

  7. Preliminary study of copper oxide nanoparticles acoustic and magnetic properties for medical imaging

    Science.gov (United States)

    Perlman, Or; Weitz, Iris S.; Azhari, Haim

    2015-03-01

    The implementation of multimodal imaging in medicine is highly beneficial as different physical properties may provide complementary information, augmented detection ability, and diagnosis verification. Nanoparticles have been recently used as contrast agents for various imaging modalities. Their significant advantage over conventional large-scale contrast agents is the ability of detection at early stages of the disease, being less prone to obstacles on their path to the target region, and possible conjunction to therapeutics. Copper ions play essential role in human health. They are used as a cofactor for multiple key enzymes involved in various fundamental biochemistry processes. Extremely small size copper oxide nanoparticles (CuO-NPs) are readily soluble in water with high colloidal stability yielding high bioavailability. The goal of this study was to examine the magnetic and acoustic characteristics of CuO-NPs in order to evaluate their potential to serve as contrast imaging agent for both MRI and ultrasound. CuO-NPs 7nm in diameter were synthesized by hot solution method. The particles were scanned using a 9.4T MRI and demonstrated a concentration dependent T1 relaxation time shortening phenomenon. In addition, it was revealed that CuO-NPs can be detected using the ultrasonic B-scan imaging. Finally, speed of sound based ultrasonic computed tomography was applied and showed that CuO-NPs can be clearly imaged. In conclusion, the preliminary results obtained, positively indicate that CuO-NPs may be imaged by both MRI and ultrasound. The results motivate additional in-vivo studies, in which the clinical utility of fused images derived from both modalities for diagnosis improvement will be studied.

  8. Preliminary study of single contrast enhanced dual energy heart imaging using dual-source CT

    International Nuclear Information System (INIS)

    Peng Jin; Zhang Longjiang; Zhou Changsheng; Lu Guangming; Ma Yan; Gu Haifeng

    2009-01-01

    Objective: To evaluate the feasibility and preliminary applications of single contrast enhanced dual energy heart imaging using dual-source CT (DSCT). Methods: Thirty patients underwent dual energy heart imaging with DSCT, of which 6 cases underwent SPECT or DSA within one week. Two experienced radiologists assessed image quality of coronary arteries and iodine map of myocardium. and correlated the coronary artery stenosis with the perfusion distribution of iodine map. Results: l00% (300/300) segments reached diagnostic standards. The mean score of image for all patients was 4.68±0.57. Mural coronary artery was present in 10 segments in S cases, atherosclerotic plaques in 32 segments in 12 cases, of which 20 segments having ≥50% stenosis, 12 segments ≤50% stenosis; dual energy CT coronary angiography was consistent with the DSA in 3 patients. 37 segmental perfusion abnormalities on iodine map were found in 15 cases, including 28 coronary blood supply segment narrow segment and 9 no coronary stenosis (including three negative segments in SPECD. Conclusion: Single contrast enhanced dual energy heart imaging can provide good coronary artery and myocardium perfusion images in the patients with appropriate heart rate, which has a potential to be used in the clinic and further studies are needed. (authors)

  9. A preliminary diffusional kurtosis imaging study of Parkinson disease: comparison with conventional diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Kamiya, Kouhei; Suzuki, Michimasa; Hori, Masaaki; Yoshida, Mariko; Aoki, Shigeki [Juntendo University School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Tomiyama, Hiroyuki; Hatano, Taku; Motoi, Yumiko; Hattori, Nobutaka [Juntendo University School of Medicine, Department of Neurology, Tokyo (Japan); Abe, Osamu [Nihon University School of Medicine, Department of Radiology, Tokyo (Japan); Shimoji, Keigo [National Center of Neurology and Psychiatry Hospital, Department of Radiology, Tokyo (Japan)

    2014-03-15

    Diffusional kurtosis imaging (DKI) is a more sensitive technique than conventional diffusion tensor imaging (DTI) for assessing tissue microstructure. In particular, it quantifies the microstructural integrity of white matter, even in the presence of crossing fibers. The aim of this preliminary study was to compare how DKI and DTI show white matter alterations in Parkinson disease (PD). DKI scans were obtained with a 3-T magnetic resonance imager from 12 patients with PD and 10 healthy controls matched by age and sex. Tract-based spatial statistics were used to compare the mean kurtosis (MK), mean diffusivity (MD), and fractional anisotropy (FA) maps of the PD patient group and the control group. In addition, a region-of-interest analysis was performed for the area of the posterior corona radiata and superior longitudinal fasciculus (SLF) fiber crossing. FA values in the frontal white matter were significantly lower in PD patients than in healthy controls. Reductions in MK occurred more extensively throughout the brain: in addition to frontal white matter, MK was lower in the parietal, occipital, and right temporal white matter. The MK value of the area of the posterior corona radiata and SLF fiber crossing was also lower in the PD group. DKI detects changes in the cerebral white matter of PD patients more sensitively than conventional DTI. In addition, DKI is useful for evaluating crossing fibers. By providing a sensitive index of brain pathology in PD, DKI may enable improved monitoring of disease progression. (orig.)

  10. Preliminary results of MR imaging of lymphoma: Distinguishing active tumor from benign residue

    International Nuclear Information System (INIS)

    Drace, J.; Baker, L.L.; Chang, P.; Castellino, R.A.

    1987-01-01

    Distinguishing tumor from benign posttreatment tissue based on both morphologic and tissue characteristics is critically important. Patients are studied before, during, and after treatment; at the time of recurrence; and on long-term follow-up. Multisection spin-echo sequences in orthogonal planes and a special single-section tissue characterization matrix of 16 different repetition time/echo time combinations are used. These basic images are used for cluster analysis (approximate fuzzy C means), T1-T2 synthetic images, linear combinations, and comparison with internal standards. Preliminary results in 35 patients imaged before treatment and 12 patients with follow-up examinations consistently show lymphoma masses to have complex architecture with high T2-weighted signal and moderate T1-weighted signal, distinct from posttreatment fibrosis. Uncommon components of active tumor with low T2-weighted signal appear distinct from fibrosis on T1-weighted images. Preliminary cluster analysis results show distinct clustering of active lymphoma versus fibrosis and biopsy-proved cystic degeneration

  11. Lumbar muscle activity during common lifts: a preliminary study using magnetic resonance imaging.

    Science.gov (United States)

    Mayer, John M; Graves, James E; Manini, Todd M; Nuzzo, James L; Ploutz-Snyder, Lori L

    2013-04-01

    The purpose of this preliminary study was to assess lumbar multifidus, erector spinae, and quadratus lumborum muscle activity during lifts as measured by changes in transverse relaxation time (T2) from magnetic resonance imaging (MRI). Thirteen healthy adults performed dynamic squat, stoop, and asymmetric stoop lifts at a standard load, with each lift followed by MRI. Increase in T2 for the multifidus and erector spinae was greater for the stoop than squat. No difference in T2 increase was noted between the multifidus and erector spinae for the squat or stoop. Increase in T2 for the contralateral multifidus was less for the asymmetric stoop than stoop. Future research using MRI and other biomechanical techniques is needed to fully characterize lumbar muscle activity during lifts for various populations, settings, postures, and loads.

  12. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Taouli, Bachir [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Kakite, Suguru [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago City (Japan); Tan, Poh Seng [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); National University Health System, Division of Gastroenterology and Hepatology, University Medicine Cluster, Singapore (Singapore); Kihira, Shingo [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Fiel, M.I. [Icahn School of Medicine at Mount Sinai, Department of Pathology, New York, NY (United States); Wagner, Mathilde [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Sorbonne Universites, UPMC, Department of Radiology, Hopital Pitie-Salpetriere, Paris (France); Llovet, Josep M. [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Universitat de Barcelona, HCC Translational Research Laboratory, Barcelona-Clinic Liver Cancer Group Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Hospital Clinic de Barcelona, Barcelona (Spain); Institucio Catalana de Recerca i Estudis Avancats, Barcelona (Spain)

    2017-11-15

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  13. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Taouli, Bachir; Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa; Kakite, Suguru; Tan, Poh Seng; Kihira, Shingo; Fiel, M.I.; Wagner, Mathilde; Llovet, Josep M.

    2017-01-01

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  14. FAIR imaging of the liver. A preliminary study

    International Nuclear Information System (INIS)

    Kiryu, Shigeru; Machida, Toru; Noda, Masanobu

    1998-01-01

    Flow-sensitive alternating inversion recovery (FAIR) technique has recently been introduced for perfusion or functional MR studies of the brain. In the imaging of liver neoplasms, the evaluation of tumor vascularity is important for diagnosis, and therefore the FAIR technique may potentially complement liver MR imaging. The purpose of this study was to evaluate the usefulness of a FAIR sequence in MR imaging of the liver and to compare it with arterial-phase images of dynamic MR imaging. One volunteer and six patients with focal hepatic lesions (one with hepatocellular carcinoma (HCC), three with metastasis, and two with cavernous hemangioma) underwent FAIR. Short TI (600 ms) and long TI (1200 ms) images were obtained during breath-hold. In normal volunteers, the vessels generated remarkably bright signal in both short and long TI. Signal intensity of liver parenchyma was low in short TI, and became stronger in long TI. Two HCC (in one patient) (100%), one hemangioma (50%), and three metastases (100%) were well delineated as bright lesions. One HCC produced peripheral high intensity in short-TI FAIR image, and this finding was consistent with the result of dynamic MR study. Another HCC, which showed no clear enhancement in the arterial-phase dynamic MRI, was visualized only in long-TI FAIR. One hemangioma, which was clearly seen in FAIR image, showed rapid and strong enhancement on dynamic MRI. It is concluded that FAIR is a promising technique for evaluation of vascularity of hepatic tumors without using contrast materials. (author)

  15. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsunobu, Y; Shiotsuki, K [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Morishita, J [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, JP (Japan)

    2015-06-15

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

  16. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    International Nuclear Information System (INIS)

    Matsunobu, Y; Shiotsuki, K; Morishita, J

    2015-01-01

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body

  17. A comparison of gallium-67 citrate scintigraphy and indium-111 labelled leukocyte imaging for the diagnosis of prosthetic joint infection. Preliminary results

    International Nuclear Information System (INIS)

    McKillop, J.H.; Cuthbert, G.F.; Gray, H.W.; McKay, Iain; Sturrock, R.D.

    1982-01-01

    Preliminary experience in comparing Gallium-67 imaging in patients with a painful prosthetic joint to the findings on Indium-111 labelled leukocyte imaging is reported. In the small series of patients so far studied, no clear advantage has emerged for either Gallium-67 or Indium-111 leukocyte imaging in terms of sensitivity or specificity for joint prosthesis infection. Should a larger group confirm the preliminary findings, Gallium-67 imaging may be preferable to Indium-111 leukocyte imaging in the patient with the painful joint prosthesis, in view of the greater simplicity of the former technique

  18. Preliminary Results Of PCA On MRO CRISM Multispectral Images

    Science.gov (United States)

    Klassen, David R.; Smith, M. D.

    2008-09-01

    Mars Reconnaissance Orbiter arrived at Mars in March 2006 and by September had achieved its science-phase orbit with the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) beginning its visible to near-infrared (VIS/NIR) spectral imaging shortly thereafter. One of the goals of CRISM is to fill in the spatial gaps between the various targeted observations, eventually mapping the entire surface. Due to the large volume of data this would create, the instrument works in a reduced spectral sampling mode creating "multispectral” images. From this data we can create image cubes using 70 wavelengths from 0.410 to 3.504 µm. We present here a preliminary analysis of these multispectral mode data products using the technique of Principal Components Analysis. Previous work with ground-based images has shown that over an entire visible hemisphere, there are only three to four meaningful components out of 32-105 wavelengths over 1.5-4.1 µm. The first two of these components are fairly consistent over all time intervals from day-to-day and season-to-season. [1-4] The preliminary work on the CRISM images cubes implies similar results_three to four significant principal components that are fairly consistent over time. We will show these components and a rough linear mixture modeling based on in-data spectral endmembers derived from the extrema of the principal components [5]. References: [1] Klassen, D. R. and Bell III, J. F. (2001) BAAS 33, 1069. [2] Klassen, D. R. and Bell III, J. F. (2003) BAAS, 35, 936. [3] Klassen, D. R., Wark, T. J., Cugliotta, C. G. (2005) BAAS, 37, 693. [4] Klassen, D. R. and Bell III, J. F. (2007) in preparation. [5] Klassen, D. R. and Bell III, J. F. (2000) BAAS, 32, 1105.

  19. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  20. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  1. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  2. Preliminary 2D design study for A ampersand PCT

    International Nuclear Information System (INIS)

    Keto, E.; Azevedo, S.; Roberson, P.

    1995-03-01

    Lawrence Livermore National Laboratory is currently designing and constructing a tomographic scanner to obtain the most accurate possible assays of radioactivity in barrels of nuclear waste in a limited amount of time. This study demonstrates a method to explore different designs using laboratory experiments and numerical simulations. In particular, we examine the trade-off between spatial resolution and signal-to-noise. The simulations are conducted in two dimensions as a preliminary study for three dimensional imaging. We find that the optimal design is entirely dependent on the expected source sizes and activities. For nuclear waste barrels, preliminary results indicate that collimators with widths of 1 to 3 inch and aspect ratios of 5:1 to 10:1 should perform well. This type of study will be repeated in 3D in more detail to optimize the final design

  3. Preliminary experiment of fast neutron imaging with direct-film method

    International Nuclear Information System (INIS)

    Pei Yuyang; Tang Guoyou; Guo Zhiyu; Zhang Guohui

    2005-01-01

    A preliminary experiment is conducted with direct-film method under the condition that fast neutron is generated by the reaction of 9 Be(d, n) on the Beijing University 4.5 MV Van de Graaff, whose energy is lower than 7 MeV. Basic characteristics of direct-film neutron radiography system are investigated with the help of samples in different materials, different thickness and holes of different diameter. The fast neutron converter, which is vital for fast neutron imaging, is produced with the materials made in China. The result indicates that fast neutron converter can meet the requirement of fast neutron imaging; further research of fast neutron imaging can be conducted on the accelerator and neutron-generator in China. (authors)

  4. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  5. Optical fiber sensors for image formation in radiodiagnostic - preliminary essays

    International Nuclear Information System (INIS)

    Carvalho, Cesar C. de; Werneck, Marcelo M.

    1998-01-01

    This work describes preliminary experiments that will bring subsidies to analyze the capability to implement a system able to capture radiological images with new sensor system, comprised by FOs scanning process and I-CCD camera. These experiments have the main objective to analyze the optical response from FOs bundle, with several typos of scintillators associated with them, when it is submitted to medical x-rays exposition. (author)

  6. Preliminary genetic imaging study of the association between estrogen receptor-α gene polymorphisms and harsh human maternal parenting.

    Science.gov (United States)

    Lahey, Benjamin B; Michalska, Kalina J; Liu, Chunyu; Chen, Qi; Hipwell, Alison E; Chronis-Tuscano, Andrea; Waldman, Irwin D; Decety, Jean

    2012-09-06

    A failure of neural changes initiated by the estrogen surge in late pregnancy to reverse the valence of infant stimuli from aversive to rewarding is associated with dysfunctional maternal behavior in nonhuman mammals. Estrogen receptor-α plays the crucial role in mediating these neural effects of estrogen priming. This preliminary study examines associations between estrogen receptor-α gene polymorphisms and human maternal behavior. Two polymorphisms were associated with human negative maternal parenting. Furthermore, hemodynamic responses in functional magnetic resonance imaging to child stimuli in neural regions associated with social cognition fully mediated the association between genetic variation and negative parenting. This suggests testable hypotheses regarding a biological pathway between genetic variants and dysfunctional human maternal parenting. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  8. Preliminary results on tests of a Cerenkov ring imaging device employing a photoionizing PWC

    Energy Technology Data Exchange (ETDEWEB)

    Durkin, S.; Honma, A.; Leith, D.W.G.S.

    1978-08-01

    A brief description of techniques and problems of ring imaging Cerenkov detectors employing photoionizing PWC's is discussed. Preliminary results on a one dimensional ring imaging device tested at SLAC in May and June of 1978 are then presented. These results include rough measurements of the Cerenkov ring in nitrogen, argon, neon, and helium produced by a collimated positron beam.

  9. Preliminary study on X-ray fluorescence computed tomography imaging of gold nanoparticles: Acceleration of data acquisition by multiple pinholes scheme

    Science.gov (United States)

    Sasaya, Tenta; Sunaguchi, Naoki; Seo, Seung-Jum; Hyodo, Kazuyuki; Zeniya, Tsutomu; Kim, Jong-Ki; Yuasa, Tetsuya

    2018-04-01

    Gold nanoparticles (GNPs) have recently attracted attention in nanomedicine as novel contrast agents for cancer imaging. A decisive tomographic imaging technique has not yet been established to depict the 3-D distribution of GNPs in an object. An imaging technique known as pinhole-based X-ray fluorescence computed tomography (XFCT) is a promising method that can be used to reconstruct the distribution of GNPs from the X-ray fluorescence emitted by GNPs. We address the acceleration of data acquisition in pinhole-based XFCT for preclinical use using a multiple pinhole scheme. In this scheme, multiple projections are simultaneously acquired through a multi-pinhole collimator with a 2-D detector and full-field volumetric beam to enhance the signal-to-noise ratio of the projections; this enables fast data acquisition. To demonstrate the efficacy of this method, we performed an imaging experiment using a physical phantom with an actual multi-pinhole XFCT system that was constructed using the beamline AR-NE7A at KEK. The preliminary study showed that the multi-pinhole XFCT achieved a data acquisition time of 20 min at a theoretical detection limit of approximately 0.1 Au mg/ml and at a spatial resolution of 0.4 mm.

  10. Preliminary Feasibility Study of the Solar Observation Payloads for STSAT-CLASS Satellites

    Directory of Open Access Journals (Sweden)

    Yong-Jae Moon

    2004-12-01

    Full Text Available In this paper, we present preliminary feasibility studies on three types of solar observation payloads for future Korean Science and Technology Satellite (STSAT programs. The three candidates are (1 an UV imaging telescope, (2 an UV spectrograph, and (3 an X-ray spectrometer. In the case of UV imaging telescope, the most important constraint seems to be the control stability of a satellite in order to obtain a reasonably good spatial resolution. Considering that the current pointing stability estimated from the data of the Far ultraviolet Imaging Spectrograph (FIMS onboard the Korean STSAT-1, is around 1 arc minutes/sec, we think that it is hard to obtain a spatial resolution sufficient for scientific research by such an UV Imaging Telescope. For solar imaging missions, we realize that an image stabilization system, which is composed of a small guide telescope with limb sensor and a servo controller of secondary mirror, is quite essential for a very good pointing stability of about 0.1 arcsec. An UV spectrograph covering the solar full disk seems to be a good choice in that there is no risk due to poor pointing stability as well as that it can provide us with valuable UV spectral irradiance data valuable for studying their effects on the Earth's atmosphere and satellites. The heritage of the FIMS can be a great advantage of developing the UV spectrograph. Its main disadvantage is that two major missions are in operation or scheduled. Our preliminary investigations show that an X-ray spectrometer for the full disk Sun seems to be the best choice among the three candidates. The reasons are : (1 high temporal and spectral X-ray data are very essential for studying the acceleration process of energetic particles associated with solar flares, (2 we have a good heritage of X-ray detectors including a rocket-borne X-ray detector, (3 in the case of developing countries such as India and Czech, solar X-ray spectrometers were selected as their early stage

  11. Coherent scattering X-ray imaging at the Brazilian National Synchrotron Laboratory: Preliminary breast images

    Energy Technology Data Exchange (ETDEWEB)

    Castro, C.R.F. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil); Barroso, R.C. [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil)]. E-mail: cely@uerij.br; Oliveira, L.F. de [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil); Lopes, R.T. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil)

    2005-08-11

    The angular distribution of coherent scatter (low-momentum transfer) carries information about atomic structures, resulting in a pattern, which can be used to reconstruct a series of images. Coherent-scatter computed tomography is a novel imaging method developed to produce cross-sectional images based on the X-ray diffraction properties of an object. A different approach to coherent X-ray imaging is possible by fixing the detector at a given scatter angle {theta}, which produces an interference peak and then, carried out a tomography in the standard way. The cross-sectional images obtained allow determining the spatial dependence of coherent scatter cross-section of selected volume elements of inhomogeneous, extend objects for a single predetermined value of {theta} of interest, leading to a simplification of the data processing and the complexity of the apparatus. This work presents preliminary coherent scattering images carried out at the X-ray Diffraction beamline of the National Synchrotron Light Laboratory in Campinas, Brazil. The specimens were excised human breast tissues fixed in formaline. No frozen procedure was used in order to minimize preferred orientation during sample preparation. About 1mm thick slices cut from each of the fresh samples were mounted in frames without windows and placed on a translator to allow acquisition of scattering spectra. Cylinders containing healthy and cancerous (infiltrating ductal carcinoma) breast tissues were imagined at the characteristic angle for adipose tissue. Transmission and coherent scatter images are compared.

  12. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  13. Image Transmission Studies

    Science.gov (United States)

    Blaine, G. James; Hill, Rexford L.; Rueter, Allen P.; Senol, Evren; Studt, James W.

    1988-06-01

    Radiological PACS image sizes and desired retrieval response times demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. Our current PACS experiments are based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel.

  14. Preliminary Image Map of the 2007 Witch Fire Perimeter, Santa Ysabel Quadrangle, San Diego County, California

    Science.gov (United States)

    Clark, Perry S.; Scratch, Wendy S.; Bias, Gaylord W.; Stander, Gregory B.; Sexton, Jenne L.; Krawczak, Bridgette J.

    2008-01-01

    In the fall of 2007, wildfires burned out of control in southern California. The extent of these fires encompassed large geographic areas that included a variety of landscapes from urban to wilderness. The U.S. Geological Survey National Geospatial Technical Operations Center (NGTOC) is currently (2008) developing a quadrangle-based 1:24,000-scale image map product. One of the concepts behind the image map product is to provide an updated map in electronic format to assist with emergency response. This image map is one of 55 preliminary image map quadrangles covering the areas burned by the southern California wildfires. Each map is a layered, geo-registered Portable Document Format (.pdf) file. For more information about the layered geo-registered .pdf, see the readme file (http://pubs.usgs.gov/of/2008/1029/downloads/CA_Agua_Dulce_of2008-1029_README.txt). To view the areas affected and the quadrangles mapped in this preliminary project, see the map index (http://pubs.usgs.gov/of/2008/1029/downloads/CA_of2008_1029-1083_index.pdf) provided with this report.

  15. Preliminary Image Map of the 2007 Buckweed Fire Perimeter, Agua Dulce Quadrangle, Los Angeles County, California

    Science.gov (United States)

    Clark, Perry S.; Scratch, Wendy S.; Bias, Gaylord W.; Stander, Gregory B.; Sexton, Jenne L.; Krawczak, Bridgette J.

    2008-01-01

    In the fall of 2007, wildfires burned out of control in southern California. The extent of these fires encompassed large geographic areas that included a variety of landscapes from urban to wilderness. The U.S. Geological Survey National Geospatial Technical Operations Center (NGTOC) is currently (2008) developing a quadrangle-based 1:24,000-scale image map product. One of the concepts behind the image map product is to provide an updated map in electronic format to assist with emergency response. This image map is one of 55 preliminary image map quadrangles covering the areas burned by the southern California wildfires. Each map is a layered, geo-registered Portable Document Format (.pdf) file. For more information about the layered geo-registered .pdf, see the readme file (http://pubs.usgs.gov/of/2008/1029/downloads/CA_Agua_Dulce_of2008-1029_README.txt). To view the areas affected and the quadrangles mapped in this preliminary project, see the map index (http://pubs.usgs.gov/of/2008/1029/downloads/CA_of2008_1029-1083_index.pdf) provided with this report.

  16. Preliminary results from a novel CVD diamond detector system for molecular imaging applications

    International Nuclear Information System (INIS)

    Mahon, A.R.

    1996-01-01

    A novel biomolecular imaging system incorporating a Chemical Vapour Deposition diamond detector is in development. The synthetic diamond is used as a UV detector to image nucleic acids in electrophoresis gels. The microstrip diamond detector currently has a spatial resolution of 30 μm. Preliminary results are presented which include: QE measurements of diamond detectors, detector time response, detector UV response and current detection limits of biomolecules in gel. The potential applications of the technology, and its significant advantages in speed and sensitivity over the current systems are discussed

  17. Functional MR imaging of cerebral auditory cortex with linguistic and non-linguistic stimulation: preliminary study

    International Nuclear Information System (INIS)

    Kang, Su Jin; Kim, Jae Hyoung; Shin, Tae Min

    1999-01-01

    To obtain preliminary data for understanding the central auditory neural pathway by means of functional MR imaging (fMRI) of the cerebral auditory cortex during linguistic and non-linguistic auditory stimulation. In three right-handed volunteers we conducted fMRI of auditory cortex stimulation at 1.5 T using a conventional gradient-echo technique (TR/TE/flip angle: 80/60/40 deg). Using a pulsed tone of 1000 Hz and speech as non-linguistic and linguistic auditory stimuli, respectively, images-including those of the superior temporal gyrus of both hemispheres-were obtained in sagittal plases. Both stimuli were separately delivered binaurally or monoaurally through a plastic earphone. Images were activated by processing with homemade software. In order to analyze patterns of auditory cortex activation according to type of stimulus and which side of the ear was stimulated, the number and extent of activated pixels were compared between both temporal lobes. Biaural stimulation led to bilateral activation of the superior temporal gyrus, while monoaural stimulation led to more activation in the contralateral temporal lobe than in the ipsilateral. A trend toward slight activation of the left (dominant) temporal lobe in ipsilateral stimulation, particularly with a linguistic stimulus, was observed. During both biaural and monoaural stimulation, a linguistic stimulus produced more widespread activation than did a non-linguistic one. The superior temporal gyri of both temporal lobes are associated with acoustic-phonetic analysis, and the left (dominant) superior temporal gyrus is likely to play a dominant role in this processing. For better understanding of physiological and pathological central auditory pathways, further investigation is needed

  18. Image transmission studies

    International Nuclear Information System (INIS)

    Blaine, G.J.; Hill, R.L.; Rueter, A.P.; Senol, E.; Studt, J.W.

    1988-01-01

    This paper discusses radiological PACS image sizes and desired retrieval response time that demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. The authors describe current PACS experiments based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel

  19. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    DEFF Research Database (Denmark)

    Rasmussen, Joachim Hee; Hemmsen, Martin Christian; Sloth Madsen, Signe

    2013-01-01

    . Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.......A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequential beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B......-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imaging (DRF-THI) in clinical scans. The scan sequence...

  20. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    Science.gov (United States)

    Rasmussen, Joachim H.; Hemmsen, Martin C.; Madsen, Signe S.; Hansen, Peter M.; Nielsen, Michael B.; Jensen, Jørgen A.

    2013-03-01

    A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequen- tial beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imag- ing (DRF-THI) in clinical scans. The scan sequence that was implemented on the UltraView system acquires both SASB-THI and DRF-THI simultaneously. Twenty-four simultaneously acquired video sequences of in-vivo abdominal SASB-THI and DRF-THI scans on 3 volunteers of 4 different sections of liver and kidney tissues were created. Videos of the in-vivo scans were presented in double blinded studies to two radiologists for image quality performance scoring. Limitations to the systems transmit stage prevented user defined transmit apodization to be applied. Field II simulations showed that side lobes in SASB could be improved by using Hanning transmit apodization. Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.

  1. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  2. Preliminary PCA/TT Results on MRO CRISM Multispectral Images

    Science.gov (United States)

    Klassen, David R.; Smith, M. D.

    2010-10-01

    Mars Reconnaissance Orbiter arrived at Mars in March 2006 and by September had achieved its science-phase orbit with the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) beginning its visible to near-infrared (VIS/NIR) spectral imaging shortly thereafter. One goal of CRISM is to fill in the spatial gaps between the various targeted observations, eventually mapping the entire surface. Due to the large volume of data this would create, the instrument works in a reduced spectral sampling mode creating "multispectral” images. From these data we can create image cubes using 64 wavelengths from 0.410 to 3.923 µm. We present here our analysis of these multispectral mode data products using Principal Components Analysis (PCA) and Target Transformation (TT) [1]. Previous work with ground-based images [2-5] has shown that over an entire visible hemisphere, there are only three to four meaningful components using 32-105 wavelengths over 1.5-4.1 µm the first two are consistent over all temporal scales. The TT retrieved spectral endmembers show nearly the same level of consistency [5]. The preliminary work on the CRISM images cubes implies similar results; three to four significant principal components that are fairly consistent over time. These components are then used in TT to find spectral endmembers which can be used to characterize the surface reflectance for future use in radiative transfer cloud optical depth retrievals. We present here the PCA/TT results comparing the principal components and recovered endmembers from six reconstructed CRISM multi-spectral image cubes. References: [1] Bandfield, J. L., et al. (2000) JGR, 105, 9573. [2] Klassen, D. R. and Bell III, J. F. (2001) BAAS 33, 1069. [3] Klassen, D. R. and Bell III, J. F. (2003) BAAS, 35, 936. [4] Klassen, D. R., Wark, T. J., Cugliotta, C. G. (2005) BAAS, 37, 693. [5] Klassen, D. R. (2009) Icarus, 204, 32.

  3. The administration of psilocybin to healthy, hallucinogen-experienced volunteers in a mock-functional magnetic resonance imaging environment: a preliminary investigation of tolerability.

    Science.gov (United States)

    Carhart-Harris, Robin L; Williams, Tim M; Sessa, Ben; Tyacke, Robin J; Rich, Ann S; Feilding, Amanda; Nutt, David J

    2011-11-01

    This study sought to assess the tolerability of intravenously administered psilocybin in healthy, hallucinogen-experienced volunteers in a mock-magnetic resonance imaging environment as a preliminary stage to a controlled investigation using functional magnetic resonance imaging to explore the effects of psilocybin on cerebral blood flow and activity. The present pilot study demonstrated that up to 2 mg of psilocybin delivered as a slow intravenous injection produces short-lived but typical drug effects that are psychologically and physiologically well tolerated. With appropriate care, this study supports the viability of functional magnetic resonance imaging work with psilocybin.

  4. Study of fish response using particle image velocimetry and high-speed, high-resolution imaging

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Richmond, M. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mueller, R. P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gruensch, G. R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-10-01

    Fish swimming has fascinated both engineers and fish biologists for decades. Digital particle image velocimetry (DPIV) and high-speed, high-resolution digital imaging are recently developed analysis tools that can help engineers and biologists better understand how fish respond to turbulent environments. This report details studies to evaluate DPIV. The studies included a review of existing literature on DPIV, preliminary studies to test the feasibility of using DPIV conducted at our Flow Biology Laboratory in Richland, Washington September through December 2003, and applications of high-speed, high-resolution digital imaging with advanced motion analysis to investigations of fish injury mechanisms in turbulent shear flows and bead trajectories in laboratory physical models. Several conclusions were drawn based on these studies, which are summarized as recommendations for proposed research at the end of this report.

  5. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  6. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  7. Rescripting Early Memories Linked to Negative Images in Social Phobia: A Pilot Study

    Science.gov (United States)

    Wild, Jennifer; Hackmann, Ann; Clark, David M.

    2008-01-01

    Negative self-images are a maintaining factor in social phobia. A retrospective study (Hackmann, A., Clark, D.M., McManus, F. (2000). Recurrent images and early memories in social phobia. Behaviour Research and Therapy, 38, 601-610) suggested that the images may be linked to early memories of unpleasant social experiences. This preliminary study…

  8. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2014-01-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic. - Highlights: ► A tomographic technique based on Rayleigh to Compton scattering ratio is proposed in order to study breast tissues. ► The Rayleigh to Compton scattering ratio technique is compared with conventional transmission technique. ► The influence of experimental parameters (energy, sample, detection system) is studied

  9. Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results.

    Science.gov (United States)

    Liu, Jing; Glenn, Orit A; Xu, Duan

    2014-04-01

    Fetal MR imaging is very challenging due to the movement of fetus and the breathing motion of the mother. Current clinical protocols involve quick 2D scouting scans to determine scan plane and often several attempts to reorient the scan plane when the fetus moves. This makes acquisition of fetal MR images clinically challenging and results in long scan times in order to obtain images that are of diagnostic quality. Compared to 2D imaging, 3D imaging of the fetus has many advantages such as higher SNR and ability to reformat images in multiple planes. However, it is more sensitive to motion and challenging for fetal imaging due to irregular fetal motion in addition to maternal breathing and cardiac motion. This aim of this study is to develop a fast 3D fetal imaging technique to resolve the challenge of imaging the moving fetus. This 3D imaging sequence has multi-echo radial sampling in-plane and conventional Cartesian encoding through plane, which provides motion robustness and high data acquisition efficiency. The utilization of a golden-ratio based projection profile allows flexible time-resolved image reconstruction with arbitrary temporal resolution at arbitrary time points as well as high signal-to-noise and contrast-to-noise ratio. The nice features of the developed image technique allow the 3D visualization of the movements occurring throughout the scan. In this study, we applied this technique to three human subjects for fetal MRI and achieved promising preliminary results of fetal brain, heart and lung imaging.

  10. Use of Diffusion Spectrum imaging in preliminary longitudinal evaluation of Amyotrophic Lateral Sclerosis: development of an imaging biomarker

    Directory of Open Access Journals (Sweden)

    Kumar eAbhinav

    2014-04-01

    Full Text Available Previous diffusion tensor imaging (DTI studies have shown white matter pathology in ALS, predominantly in the motor pathways. Further these studies have shown that DTI can be used longitudinally to track pathology over time, making white matter pathology a candidate as an outcome measure in future trials. DTI has demonstrated application in group studies, however its derived indices, for example fractional anisotropy, are susceptible to partial volume effects, making its role questionable in examining individual progression. We hypothesize that changes in the white matter are present in ALS beyond the motor tracts, and that the affected pathways and associated pattern of disease progression can be tracked longitudinally using automated diffusion connectometry analysis. Connectometry analysis is based on diffusion spectrum imaging (DSI and overcomes the limitations of a conventional tractography approach and DTI. The identified affected white matter tracts can then be assessed in a targeted fashion using High definition fiber tractography (a novel white matter MR imaging technique. Changes in quantitative and qualitative markers over time could then be correlated with clinical progression.We illustrate these principles towards developing an imaging biomarker for demonstrating individual progression, by presenting results for five ALS patients, including with longitudinal data in two. Preliminary analysis demonstrated a number of changes bilaterally and asymmetrically in motoric and extramotoric white matter pathways. Further the limbic system was also affected possibly explaining the cognitive symptoms in ALS. In the two longitudinal subjects, the white matter changes were less extensive at baseline, although there was evidence of disease progression in a frontal pattern with a relatively spared postcentral gyrus, consistent with the known pathology in ALS.

  11. Preliminary study of image findings of femoroacetabular impingement

    International Nuclear Information System (INIS)

    Guo Zhe; Zhang Jing; Hong Nan; Cheng Xiaoguang

    2010-01-01

    Objective: To assess the image findings of femoroacetabular impingement (FAI). Methods: Image findings of 9 patients with surgically proved femoroacetabular impingement were retrospectively reviewed for characteristic image findings of FAI. All 9 patients underwent X-ray examinations and MRI of affected hip, and 1 patient underwent MR arthrography (MRA) additionally. Results: X-ray examinations of all 9 patients showed bump at femoral head-neck junction or overcoverage of the acetabular. MRI showed various degrees of injury of anterosuperior labrum in all 9 patients. The injuries were stage Ⅰ A in 2 cases, stage Ⅰ B in 3, stage Ⅱ A in 2, and stage Ⅱ B in 2. MRA of the case showed tears of anterosuperior labrum, with contrast media entering into the teared labrum. There were sclerosis and cystic degeneration of subchondral bone of femoral head in 2 cases, and these findings were confirmed as cartilage delamination by surgery. Conclusions: MRI can display the injures of labrum and articular cartilage, which is helpful to the early diagnosis of' FAI. (authors)

  12. DWI-based neural fingerprinting technology: a preliminary study on stroke analysis.

    Science.gov (United States)

    Ye, Chenfei; Ma, Heather Ting; Wu, Jun; Yang, Pengfei; Chen, Xuhui; Yang, Zhengyi; Ma, Jingbo

    2014-01-01

    Stroke is a common neural disorder in neurology clinics. Magnetic resonance imaging (MRI) has become an important tool to assess the neural physiological changes under stroke, such as diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI). Quantitative analysis of MRI images would help medical doctors to localize the stroke area in the diagnosis in terms of structural information and physiological characterization. However, current quantitative approaches can only provide localization of the disorder rather than measure physiological variation of subtypes of ischemic stroke. In the current study, we hypothesize that each kind of neural disorder would have its unique physiological characteristics, which could be reflected by DWI images on different gradients. Based on this hypothesis, a DWI-based neural fingerprinting technology was proposed to classify subtypes of ischemic stroke. The neural fingerprint was constructed by the signal intensity of the region of interest (ROI) on the DWI images under different gradients. The fingerprint derived from the manually drawn ROI could classify the subtypes with accuracy 100%. However, the classification accuracy was worse when using semiautomatic and automatic method in ROI segmentation. The preliminary results showed promising potential of DWI-based neural fingerprinting technology in stroke subtype classification. Further studies will be carried out for enhancing the fingerprinting accuracy and its application in other clinical practices.

  13. A pancreas imaging agent-131I-HIPDM: the animal experiment and preliminary clinical application

    International Nuclear Information System (INIS)

    Shao Hesheng

    1988-01-01

    131 I-HIPDM has been used clinically for studying regional cerebral perfusion. The [ 131 I] HIPDM was prepared in a kit. The labelling yields were consistently more than 95%, as analyzed by the TLC-Silica gel. The labelled compound is stable in vitro and in vivo. S D Strain rats (170-220 g) and mice (18-22 g) were used. The pancreatic uptake of [ 131 I] HIPDM is rather slow in mice and rats. At 8 hr after iv, the pancreas activity and the pancreas to liver (P/L) ratio are highest in mice and rats. The effect of carrier loading dose from 0.010 to 6.0 mg/kg on blodistribution in mice has been studied. The liver uptake was increased by adding carrier HIPDM. The result indicates that administration between 0.010 and 0.05 mg/kg carrier dose is most suitable for the pancreas imaging. Gamma camera imaging of dog at 6 hr after iv with 300 μCi [ 131 I] HIPMD, 0.05 mg/kg body weight showed clear pancreas image. The P/L ratio of the dog is 0.40. Preliminary clinical tests were satisfactory. Using 1 to 1.5 mCi of [ 131 I] HIPDM, 0.05 mg/kg, the pancreas imaging was operated in 4 cases of volunteers and pancreas cyst respectively with the good diagnostic quality. The authors are of the opinion that this pancreas imaging agent may have potential value for routine use

  14. Sensitivity Measurement of Transmission Computer Tomography: thePreliminary Experimental Study

    International Nuclear Information System (INIS)

    Widodo, Chomsin-S; Sudjatmoko; Kusminarto; Agung-BS Utomo; Suparta, Gede B

    2000-01-01

    This paper reports result of preliminary experimental study onmeasurement method for sensitivity of a computed tomography (CT) scanner. ACT scanner has been build at the Department of Physics, FMIPA UGM and itsperformance based on its sensitivity was measured. The result showed that themeasurement method for sensitivity confirmed this method may be developedfurther as a measurement standard. Although the CT scanner developed has anumber of shortcoming, the analytical results from the sensitivitymeasurement suggest a number of reparations and improvements for the systemso that improved reconstructed CT images can be obtained. (author)

  15. Development and Reliability of a Preliminary Foot Osteoarthritis Magnetic Resonance Imaging Score.

    Science.gov (United States)

    Halstead, Jill; Martín-Hervás, Carmen; Hensor, Elizabeth M A; McGonagle, Dennis; Keenan, Anne-Maree; Redmond, Anthony C; Conaghan, Philip G

    2017-08-01

    Foot osteoarthritis (OA) is very common but underinvestigated musculoskeletal condition and there is little consensus as to common magnetic resonance imaging (MRI) features. The aim of this study was to develop a preliminary foot OA MRI score (FOAMRIS) and evaluate its reliability. This preliminary semiquantitative score included the hindfoot, midfoot, and metatarsophalangeal joints. Joints were scored for joint space narrowing (JSN; 0-3), osteophytes (0-3), joint effusion/synovitis, and bone cysts (present/absent). Erosions and bone marrow lesions (BML) were scored (0-3) and BML were evaluated adjacent to entheses and at sub-tendon sites (present/absent). Additionally, tenosynovitis (0-3) and midfoot ligament pathology (present/absent) were scored. Reliability was evaluated in 15 people with foot pain and MRI-detected OA using 3.0T MRI multi-sequence protocols, and assessed using ICC as an overall score and per anatomical site. Intrareader agreement (ICC) was generally good to excellent across the foot in joint features (JSN 0.90, osteophytes 0.90, effusion/synovitis 0.46, cysts 0.87), bone features (BML 0.83, erosion 0.66, BML entheses 0.66, BML sub-tendon 0.60) and soft tissue features (tenosynovitis 0.83, ligaments 0.77). Interreader agreement was lower for joint features (JSN 0.43, osteophytes 0.27, effusion/synovitis 0.02, cysts 0.48), bone features (BML 0.68, erosion 0.00, BML entheses 0.34, BML sub-tendon 0.13), and soft tissue features (tenosynovitis 0.35, ligaments 0.33). This preliminary FOAMRIS demonstrated good intrareader reliability and fair interreader reliability when assessing the total feature scores. Further development is required in cohorts with a range of pathologies and to assess the psychometric measurement properties.

  16. Preliminary Results of Clover and Grass Coverage and Total Dry Matter Estimation in Clover-Grass Crops Using Image Analysis

    Directory of Open Access Journals (Sweden)

    Anders K. Mortensen

    2017-12-01

    Full Text Available The clover-grass ratio is an important factor in composing feed ratios for livestock. Cameras in the field allow the user to estimate the clover-grass ratio using image analysis; however, current methods assume the total dry matter is known. This paper presents the preliminary results of an image analysis method for non-destructively estimating the total dry matter of clover-grass. The presented method includes three steps: (1 classification of image illumination using a histogram of the difference in excess green and excess red; (2 segmentation of clover and grass using edge detection and morphology; and (3 estimation of total dry matter using grass coverage derived from the segmentation and climate parameters. The method was developed and evaluated on images captured in a clover-grass plot experiment during the spring growing season. The preliminary results are promising and show a high correlation between the image-based total dry matter estimate and the harvested dry matter ( R 2 = 0.93 with an RMSE of 210 kg ha − 1 .

  17. Image of Women in Advertisements: A Preliminary Study of Avenues for Change.

    Science.gov (United States)

    Butler-Paisley, Matilda, Ed.; And Others

    The Center for Research on Women (CROW) at Stanford University along with the Communication Department, the Psychology Department, and the School of Education conducted a study on the image of women in advertising and suggested ways to improve women's image in the advertising media. With the objective of sponsoring some alternatives to expedite…

  18. A preliminary study on cone beam CT image based treatment planning

    International Nuclear Information System (INIS)

    Padmanaban, Sriram; Jeevanandham, Prakash; Boopathy, Raghavendiran; Sukumar, Prabakar; Syam Kumar, S.A.; Kunjithapatham, Bhuvana; Nagarajan, Vivekanandan

    2008-01-01

    Kilovolt Cone beam computed tomography (CBCT) based on flat panel technology is primarily used for positioning verification. However it is required to evaluate the accuracy of dose calculation based on CBCT images for the purpose of re-planning in adaptive radiation therapy (ART). In this study, 3DCRT and IMRT plans were done using both the planning CT and CBCT images and the corresponding variations in dose and MUs were analyzed, hence evaluating the feasibility of using kilovolt CBCT for dose calculation and patient dose verification. (author)

  19. Photoacoustic imaging for differential diagnosis of benign polyps versus malignant polyps of the gallbladder: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Hee Dong; Lee, Jae Young; Han, Joon Koo [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul (Korea, Republic of); Jang, Jin Young; Kang, Mee Joo [Div. of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Chang, Jin Ho; Kang, Jeeun [Sogang University, Seoul (Korea, Republic of)

    2017-09-15

    To investigate the feasibility of ex vivo multispectral photoacoustic (PA) imaging in differentiating cholesterol versus neoplastic polyps, and benign versus malignant polyps, of the gallbladder. A total of 38 surgically confirmed gallbladder polyps (24 cholesterol polyps, 4 adenomas, and 10 adenocarcinomas) from 38 patients were prospectively included in this study. The surgical specimens were set on a gel pad immersed in a saline-filled container. The PA intensities of polyps were then measured, using two separate wavelength intervals (421–647 nm and 692–917 nm). Mann-Whitney U test was performed for the comparison of normalized PA intensities between the cholesterol and neoplastic polyps, and between the benign and malignant polyps. Kruskal-Wallis test was conducted for the comparison of normalized PA intensities among the cholesterol polyps, adenomas, and adenocarcinomas. A significant difference was observed in the normalized PA intensities between the cholesterol and neoplastic polyps at 459 nm (median, 1.00 vs. 0.73; p = 0.032). Comparing the benign and malignant polyps, there were significant differences in the normalized PA intensities at 765 nm (median, 0.67 vs. 0.78; p = 0.013), 787 nm (median, 0.65 vs. 0.77; p = 0.034), and 853 nm (median, 0.59 vs. 0.85; p = 0.028). The comparison of the normalized PA intensities among cholesterol polyps, adenomas, and adenocarcinomas demonstrated marginally significant differences at 765 nm (median, 0.67 vs. 0.66 vs. 0.78, respectively; p = 0.049). These preliminary results indicate that benign versus malignant gallbladder polyps might exhibit different spectral patterns on multispectral PA imaging.

  20. Photoacoustic imaging for differential diagnosis of benign polyps versus malignant polyps of the gallbladder: A preliminary study

    International Nuclear Information System (INIS)

    Chae, Hee Dong; Lee, Jae Young; Han, Joon Koo; Jang, Jin Young; Kang, Mee Joo; Chang, Jin Ho; Kang, Jeeun

    2017-01-01

    To investigate the feasibility of ex vivo multispectral photoacoustic (PA) imaging in differentiating cholesterol versus neoplastic polyps, and benign versus malignant polyps, of the gallbladder. A total of 38 surgically confirmed gallbladder polyps (24 cholesterol polyps, 4 adenomas, and 10 adenocarcinomas) from 38 patients were prospectively included in this study. The surgical specimens were set on a gel pad immersed in a saline-filled container. The PA intensities of polyps were then measured, using two separate wavelength intervals (421–647 nm and 692–917 nm). Mann-Whitney U test was performed for the comparison of normalized PA intensities between the cholesterol and neoplastic polyps, and between the benign and malignant polyps. Kruskal-Wallis test was conducted for the comparison of normalized PA intensities among the cholesterol polyps, adenomas, and adenocarcinomas. A significant difference was observed in the normalized PA intensities between the cholesterol and neoplastic polyps at 459 nm (median, 1.00 vs. 0.73; p = 0.032). Comparing the benign and malignant polyps, there were significant differences in the normalized PA intensities at 765 nm (median, 0.67 vs. 0.78; p = 0.013), 787 nm (median, 0.65 vs. 0.77; p = 0.034), and 853 nm (median, 0.59 vs. 0.85; p = 0.028). The comparison of the normalized PA intensities among cholesterol polyps, adenomas, and adenocarcinomas demonstrated marginally significant differences at 765 nm (median, 0.67 vs. 0.66 vs. 0.78, respectively; p = 0.049). These preliminary results indicate that benign versus malignant gallbladder polyps might exhibit different spectral patterns on multispectral PA imaging

  1. Caligula-Christ: Preliminary Study of a Parallel

    Directory of Open Access Journals (Sweden)

    Lorene M. Birden

    2010-01-01

    Full Text Available Caligula, at the very beginning of the Albert Camus play, conceives a very ambitious project; to surpass the gods and take their place in his empire, in order to decree impossibility. Camus has, however, gone a step further in developing the god-image of his main character through the incorporation of much Christian imagery into the scenes. This aspect of the play seems not to have been noticed by Camus scholars; there is no in-depth study of the use of this imagery. However, Camus scholar Patricia Johnson and the members of the Société des études camusiennes have noted the usefulness of the analysis presented here and the absence of it in previous research. This study, designated as “preliminary,” attempts to prompt further analyses of the question and offers different approaches. It proceeds by intertextual study of Caligula and the gospels (here referred to in Revised Standard Version and brings out aspects of the emperor’s intentions that expose a combination of perversion and similarity in relation to deity. It briefly outlines the sources of this parallel and the reasons for creating it, then details the parallels that show first the reversal of the image of Jesus, then the striking consonance. It ends with interpretations of the parallels and concludes with commentaries on the use of irony to create them.

  2. A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study

    International Nuclear Information System (INIS)

    Im, Chang-Hwan; Lee, Soo Yeol

    2006-01-01

    fMRI-constrained EEG/MEG source imaging can be a powerful tool in studying human brain functions with enhanced spatial and temporal resolutions. Recent studies on the combination of fMRI and EEG/MEG have suggested that fMRI prior information could be readily implemented by simply imposing different weighting factors to cortical sources overlapping with the fMRI activations. It has been also reported, however, that such a hard constraint may cause severe distortions or elimination of meaningful EEG/MEG sources when there are distinct mismatches between the fMRI activations and the EEG/MEG sources. If one wants to obtain the actual EEG/MEG source locations and uses the fMRI prior information as just an auxiliary tool to enhance focality of the distributed EEG/MEG sources, it is reasonable to weaken the strength of fMRI constraint when severe mismatches between fMRI and EEG/MEG sources are observed. The present study suggests an efficient technique to automatically adjust the strength of fMRI constraint according to the mismatch level. The use of the proposed technique rarely affects the results of conventional fMRI-constrained EEG/MEG source imaging if no major mismatch between the two modalities is detected; while the new results become similar to those of typical EEG/MEG source imaging without fMRI constraint if the mismatch level is significant. A preliminary simulation study using realistic EEG signals demonstrated that the proposed technique can be a promising tool to selectively apply fMRI prior information to EEG/MEG source imaging

  3. Preliminary results for X-ray phase contrast micro-tomography on the biomedical imaging beamline at SSRF

    International Nuclear Information System (INIS)

    Chen Rongchang; Du Guohao; Xie Honglan; Deng Biao; Tong Yajun; Hu Wen; Xue Yanling; Chen Can; Ren Yuqi; Zhou Guangzhao; Wang Yudan; Xiao Tiqiao; Xu Hongjie; Zhu Peiping

    2009-01-01

    With X-ray phase contrast micro-tomography(CT), one is able to obtain edge-enhanced image of internal structure of the samples. This allows visualization of the fine internal features for biology tissues, which is not able to resolve by conventional absorption CT. After preliminary modulation, monochromatic X-rays (8-72.5 keV) are available for experiments on the experimental station of the biomedical imaging beamline at Shanghai Synchrotron Radiation Facility(SSRF). In this paper, we report the in line phase contrast micro-tomography(IL-XPCT) of biology sample (locust) on the beamline. The reconstruct slice images and three dimensional rendering images of the locust were obtained, with clearly visible images of locus's wing, surface texture and internal tissue distribution. (authors)

  4. DWI-Based Neural Fingerprinting Technology: A Preliminary Study on Stroke Analysis

    Directory of Open Access Journals (Sweden)

    Chenfei Ye

    2014-01-01

    Full Text Available Stroke is a common neural disorder in neurology clinics. Magnetic resonance imaging (MRI has become an important tool to assess the neural physiological changes under stroke, such as diffusion weighted imaging (DWI and diffusion tensor imaging (DTI. Quantitative analysis of MRI images would help medical doctors to localize the stroke area in the diagnosis in terms of structural information and physiological characterization. However, current quantitative approaches can only provide localization of the disorder rather than measure physiological variation of subtypes of ischemic stroke. In the current study, we hypothesize that each kind of neural disorder would have its unique physiological characteristics, which could be reflected by DWI images on different gradients. Based on this hypothesis, a DWI-based neural fingerprinting technology was proposed to classify subtypes of ischemic stroke. The neural fingerprint was constructed by the signal intensity of the region of interest (ROI on the DWI images under different gradients. The fingerprint derived from the manually drawn ROI could classify the subtypes with accuracy 100%. However, the classification accuracy was worse when using semiautomatic and automatic method in ROI segmentation. The preliminary results showed promising potential of DWI-based neural fingerprinting technology in stroke subtype classification. Further studies will be carried out for enhancing the fingerprinting accuracy and its application in other clinical practices.

  5. Digital assessment of preliminary impression accuracy for edentulous jaws: Comparisons of 3-dimensional surfaces between study and working casts.

    Science.gov (United States)

    Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Watanabe, Megumi; Tomotake, Yoritoki; Nagao, Kan; Ichikawa, Tetsuo

    2016-07-01

    The aim of this study was to compare 3-dimensional surfaces of study and working casts for edentulous jaws and to evaluate the accuracy of preliminary impressions with a view to the future application of digital dentistry for edentulous jaws. Forty edentulous volunteers were serially recruited. Nine dentists took preliminary and final impressions in a routine clinical work-up. The study and working casts were digitized using a dental 3-dimensional scanner. The two surface images were superimposed through a least-square algorithm using imaging software and compared qualitatively. Furthermore, the surface of each jaw was divided into 6 sections, and the difference between the 2 images was quantitatively evaluated. Overall inspection showed that the difference around residual ridges was small and that around borders were large. The mean differences in the upper and lower jaws were 0.26mm and 0.45mm, respectively. The maximum values of the differences showed that the upward change mainly occurred in the anterior residual ridge, and the downward change mainly in the posterior border seal, and the labial and buccal vestibules, whereas every border of final impression was shortened in the lower jaw. The accuracy in all areas except the border, which forms the foundation, was estimated to be less than 0.25mm. Using digital technology, we here showed the overall and sectional accuracy of the preliminary impression for edentulous jaws. In our clinic, preliminary impressions have been made using an alginate material while ensuring that the requisite impression area was covered. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Clinical and imaging characteristics of the vascular dementia. Preliminary studies

    International Nuclear Information System (INIS)

    Gomez Viera, Nelson; Rivero Arias, Edmundo; Perez Nellar, Jesus; Begueria Santos, Ramon; Arias Sifontes, William; Raiteris Flores, Juan

    1997-01-01

    A descriptive prospective study was carried out in 41 patients presenting with vascular dementia from Habana Vieja municipality, Havana City, in order to know some of the clinical and imaging characteristics of this disease. The main risk factors observed were the history of cerebrovascular disease and arterial hypertension. Depression, sleeping disorders and focal and pseudo bulbar neurologic signs were the most frequent clinical findings. Folstein neuropsychological test evidenced an important disorder of attention, calculation, the evocation memory and orientation. According to this test, 29 % of the patients had a severe dementia and nearly 50 % showed a severe handicap. The most frequent imaging findings observed in the computerized axial tomography of the cranium were cerebral atrophy, and single or multiple infarctions. Multiple cerebral infarctions, the lacunar status, subcortical encephalopathy of Binswanger, and single infarction located in cerebral areas related to cognition were considered as possible psychopathological mechanisms associated with the disease

  7. Dynamic gadolinium-enhanced subtraction MR imaging - a simple technique for the early diagnosis of Legg-Calve-Perthes disease: preliminary results

    International Nuclear Information System (INIS)

    Sebag, G.; Ducou Le Pointe, H.; Klein, I.; Maiza, D.; Mazda, K.; Bensahel, H.; Hassan, M.

    1997-01-01

    To determine whether the simple technique of dynamic gadolinium-enhanced subtraction MR imaging, which is available on standard MR units, can detect ischemia of the femoral head in children with early Legg-Calve-Perthes disease (LCP). Bone perfusion of eight hips in four patients (mean age 7.5 years) was studied using dynamic gadolinium-enhanced substraction MR imaging at the onset of proven LCP (with initial negative plain films). Enhancement of subtracted images was compared with that on standard MR images and with bone scintigraphy findings. Subtraction MR imaging depicted ischemia as a widespread absence of enhancement and was in good agreement with bone scintigraphy. The subtraction technique improved the sensitivity and the specificity of MR imaging in two children. Furthermore, subtraction MR imaging allowed recognition of the pattern of early reperfusion. Our preliminary results indicate that dynamic gadolinium-enhanced subtraction MRI is a simple and promising means of early recognition of ischemia in LCP. (orig.)

  8. Preliminary studies of enhanced contrast radiography in anatomy and embryology of insects with Elettra synchrotron light

    International Nuclear Information System (INIS)

    Hoennicke, M.G.; Foerster, L.A.; Navarro-Silva, M.A.; Menk, R.-H.; Rigon, L.; Cusatis, C.

    2005-01-01

    Enhanced contrast X-ray imaging is achieved by exploiting the real part of the refraction index, which is responsible for the phase shifts, in addition to the imaginary part, which is responsible for the absorption. Such techniques are called X-ray phase contrast imaging. An analyzer-based X-ray phase contrast imaging set-up with Diffraction Enhanced Imaging processing (DEI) were used for preliminary studies in anatomy and embryology of insects. Parasitized stinkbug and moth eggs used as control agents of pests in vegetables and adult stinkbugs and mosquitoes (Aedes aegypti) were used as samples. The experimental setup was mounted in the SYRMEP beamline at ELETTRA. Images were obtained using a high spatial resolution CCD detector (pixel size 14x14μm 2 ) coupled with magnifying optics. Analyzer-based X-ray phase contrast images (PCI) and edge detection images show contrast and details not observed with conventional synchrotron radiography and open the possibility for future study in the embryonic development of insects

  9. Magnetic resonance imaging features of the spinal cord in pediatric multiple sclerosis: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Verhey, Leonard H. [Hospital for Sick Children, Neuroscience and Mental Health, Toronto, ON (Canada); University of Toronto, Institute of Medical Science, Faculty of Medicine, Toronto, ON (Canada); Branson, Helen M.; Shroff, Manohar [Hospital for Sick Children, Department of Diagnostic Imaging (Neuroradiology), Toronto, ON (Canada); University of Toronto, Department of Medical Imaging, Toronto, ON (Canada); Makhija, Monica [Hospital for Sick Children, Neuroscience and Mental Health, Toronto, ON (Canada); Banwell, Brenda [Hospital for Sick Children, Neuroscience and Mental Health, Toronto, ON (Canada); University of Toronto, Institute of Medical Science, Faculty of Medicine, Toronto, ON (Canada); University of Toronto, Department of Pediatrics (Neurology), Toronto, ON (Canada)

    2010-12-15

    Spinal cord lesions in adults with multiple sclerosis (MS) are thought to contribute to disability. The magnetic resonance imaging (MRI) appearance and clinical correlates of spinal cord lesions in children with MS have not been reported. T1-weighted pre- and post-gadolinium and T2-weighted TSE/FSE spine MR images of 36 children (age, 14.3 {+-} 3.3) with relapsing-remitting MS (annualized relapse rate, 0.7; disease duration, 7.5 {+-} 3.3 years) were analyzed for total lesion count, lesion location and length, intramedullary extent, and gadolinium enhancement. Clinical, demographic, laboratory, and MRI data were correlated. Lesions preferentially involved the cervical region, were predominantly focal, and involved only a portion of the transverse cord diameter. However, ten of 36 patients demonstrated longitudinally extensive lesions. Children with the highest clinical relapse rate also tended to have more spinal cord lesions and were more likely to accrue new lesions on serial spinal scans. These preliminary data suggest that MS lesions of the spinal cord in children are radiographically similar to that of adult-onset MS - supporting a common biology of pediatric- and adult-onset disease. However, children with relapsing-remitting MS can also develop longitudinally extensive lesions, suggesting that such lesions may be less specific for diseases such as neuromyelitis optica in pediatric patients. All patients recovered well from spinal cord attacks, and the presence of spinal cord lesions in the first few years of disease did not correlate with physical disability. Measures of spinal cord atrophy and longer periods of observation are required to determine the impact of spinal cord involvement in pediatric-onset MS. (orig.)

  10. Magnetic resonance imaging features of the spinal cord in pediatric multiple sclerosis: a preliminary study

    International Nuclear Information System (INIS)

    Verhey, Leonard H.; Branson, Helen M.; Shroff, Manohar; Makhija, Monica; Banwell, Brenda

    2010-01-01

    Spinal cord lesions in adults with multiple sclerosis (MS) are thought to contribute to disability. The magnetic resonance imaging (MRI) appearance and clinical correlates of spinal cord lesions in children with MS have not been reported. T1-weighted pre- and post-gadolinium and T2-weighted TSE/FSE spine MR images of 36 children (age, 14.3 ± 3.3) with relapsing-remitting MS (annualized relapse rate, 0.7; disease duration, 7.5 ± 3.3 years) were analyzed for total lesion count, lesion location and length, intramedullary extent, and gadolinium enhancement. Clinical, demographic, laboratory, and MRI data were correlated. Lesions preferentially involved the cervical region, were predominantly focal, and involved only a portion of the transverse cord diameter. However, ten of 36 patients demonstrated longitudinally extensive lesions. Children with the highest clinical relapse rate also tended to have more spinal cord lesions and were more likely to accrue new lesions on serial spinal scans. These preliminary data suggest that MS lesions of the spinal cord in children are radiographically similar to that of adult-onset MS - supporting a common biology of pediatric- and adult-onset disease. However, children with relapsing-remitting MS can also develop longitudinally extensive lesions, suggesting that such lesions may be less specific for diseases such as neuromyelitis optica in pediatric patients. All patients recovered well from spinal cord attacks, and the presence of spinal cord lesions in the first few years of disease did not correlate with physical disability. Measures of spinal cord atrophy and longer periods of observation are required to determine the impact of spinal cord involvement in pediatric-onset MS. (orig.)

  11. Three dimensional CT imaging of ossicular chain: a preliminary study

    International Nuclear Information System (INIS)

    Hu Chunhong; Zhong Shenbin; Fu Yindi; Zhu Wei; Wang Xueyuan; Chen Jianhua; Ding Yi

    2001-01-01

    Objective: To analysis the features of normal and abnormal ossicular chain in three dimensional images and asses the best parameters and its usefulness in diagnosis and treatment of chronic otitis media (COM). Methods: All patients, including 43 patients with normal ears and 24 ears with COM, were examined using spiral CT with inner ear software, 1-mm slice width and 1 pitch. SSD method was used in three dimensional reconstruction and the threshold was 100-300 Hu. Results: In normal cases, Malleus, incus, stapes crura, incudomalleal joints and incudostapedial joints were displayed well, but stapes footplate unsatisfactorily. The disruption of the ossicular chain showed in three-dimensional images in cases of chronic otitis media was in accord with that seen in the operation. Conclusion: It is very important for imaging with high quality through selecting proper parameters, and three-dimensional image can provide valuable information for surgery

  12. Preliminary study on the Validation of FY-4A Lightning Mapping Imager

    Science.gov (United States)

    Cao, D.; Lu, F.; Qie, X.; Zhang, X.; Huang, F.; Wang, D.

    2017-12-01

    The FengYun-4 (FY-4) geostationary meteorological satellite is the second generation of China's geostationary meteorological satellite. The FY-4A was launched on December 11th, 2016. It includes a new instrument Lightning Mapping Imager (LMI) for total lightning (cloud and cloud-to-ground flashes) detection. The LMI operates at a wavelength of 777.4nm with 1.9ms integrated time. And it could observe lightning activity continuously day and night with spatial resolution of 7.8 km (sub satellite point) over China region. The product algorithm of LMI consists of false signal filtering and flash clustering analysis. The false signal filtering method is used to identify and remove non-lightning artifacts in optical events. The flash clustering analysis method is used to cluster "event" into "group" and "flash" using specified time and space threshold, and the other non-lightning optical events are filtered further more in the clustering analysis. The ground-based lightning location network (LLN) in China and WWLLN (World Wide Lightning Location Network) were both used to make preliminary validation of LMI. The detection efficiency for cloud-to-ground lightning, spatial and temporal accuracy of LMI were estimated by the comparison of lightning observations from ground-based network and LMI. The day and night biases were also estiamted. Although the LLN and WWLLN mainly observe return strokes in cloud-to-ground flash, the accuracy of LMI still could be estimated for that it was not associated with the flash type mostly. The false alarm efficiency of LMI was estimated using the Geostationary Interferometric Infrared Sounder (GIIRS), another payloads on the FY-4A satellite. The GIIRS could identify the convective cloud region and give more information about the cloud properties. The GIIRS products were used to make a rough evaluation of false alarm efficiency of LMI. The results of this study reveal details of characteristics of LMI instrument. It is also found that the

  13. [Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].

    Science.gov (United States)

    Mészáros, Norbert; Major, Tibor; Stelczer, Gábor; Zaka, Zoltán; Mózsa, Emõke; Fodor, János; Polgár, Csaba

    2015-06-01

    The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.

  14. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  15. Preliminary investigations into macroscopic attenuated total reflection-fourier transform infrared imaging of intact spherical domains: spatial resolution and image distortion.

    Science.gov (United States)

    Everall, Neil J; Priestnall, Ian M; Clarke, Fiona; Jayes, Linda; Poulter, Graham; Coombs, David; George, Michael W

    2009-03-01

    This paper describes preliminary investigations into the spatial resolution of macro attenuated total reflection (ATR) Fourier transform infrared (FT-IR) imaging and the distortions that arise when imaging intact, convex domains, using spheres as an extreme example. The competing effects of shallow evanescent wave penetration and blurring due to finite spatial resolution meant that spheres within the range 20-140 microm all appeared to be approximately the same size ( approximately 30-35 microm) when imaged with a numerical aperture (NA) of approximately 0.2. A very simple model was developed that predicted this extreme insensitivity to particle size. On the basis of these studies, it is anticipated that ATR imaging at this NA will be insensitive to the size of intact highly convex objects. A higher numerical aperture device should give a better estimate of the size of small spheres, owing to superior spatial resolution, but large spheres should still appear undersized due to the shallow sampling depth. An estimate of the point spread function (PSF) was required in order to develop and apply the model. The PSF was measured by imaging a sharp interface; assuming an Airy profile, the PSF width (distance from central maximum to first minimum) was estimated to be approximately 20 and 30 microm for IR bands at 1600 and 1000 cm(-1), respectively. This work has two significant limitations. First, underestimation of domain size only arises when imaging intact convex objects; if surfaces are prepared that randomly and representatively section through domains, the images can be analyzed to calculate parameters such as domain size, area, and volume. Second, the model ignores reflection and refraction and assumes weak absorption; hence, the predicted intensity profiles are not expected to be accurate; they merely give a rough estimate of the apparent sphere size. Much further work is required to place the field of quantitative ATR-FT-IR imaging on a sound basis.

  16. Non-invasive imaging of zebrafish with spinal deformities using optical coherence tomography: a preliminary study

    Science.gov (United States)

    Bernstein, Liane; Beaudette, Kathy; Patten, Kessen; Beaulieu-Ouellet, Émilie; Strupler, Mathias; Moldovan, Florina; Boudoux, Caroline

    2013-03-01

    A zebrafish model has recently been introduced to study various genetic mutations that could lead to spinal deformities such as scoliosis. However, current imaging techniques make it difficult to perform longitudinal studies of this condition in zebrafish, especially in the early stages of development. The goal of this project is to determine whether optical coherence tomography (OCT) is a viable non-invasive method to image zebrafish exhibiting spinal deformities. Images of both live and fixed malformed zebrafish (5 to 21 days postfertilization) as well as wild-type fish (5 to 29 days postfertilization) were acquired non-invasively using a commercial SD-OCT system, with a laser source centered at 930nm (λ=100nm), permitting axial and lateral resolutions of 7 and 8μm respectively. Using two-dimensional images and three-dimensional reconstructions, it was possible to identify the malformed notochord as well as deformities in other major organs at different stages of formation. Visualization of the notochord was facilitated with the development of a segmentation algorithm. OCT images were compared to HE histological sections and images obtained by calcein staining. Because of the possibility of performing longitudinal studies on a same fish and reducing image processing time as compared with staining techniques and histology, the use of OCT could facilitate phenotypic characterization in studying genetic factors leading to spinal deformities in zebrafish and could eventually contribute to the identification of the genetic causes of spinal deformities such as scoliosis.

  17. R and D Requirements, RF Gun Mode Studies, FEL-2 Steady-State Studies, Preliminary FEL-1 Time-Dependent Studies, and Preliminary Layout Option Investigation

    International Nuclear Information System (INIS)

    Byrd, John; Corlett, John; Doolittle, Larry; Fawley, William; Lidia, Steven; Penn, Gregory; Ratti, Alex; Staples, John; Wilcox Russell; Wurtele, Jonathan; Zholents, Alexander

    2005-01-01

    This report constitutes the third deliverable of LBNLs contracted role in the FERMI (at) Elettra Technical Optimization study. It describes proposed RandD activities for the baseline design of the Technical Optimization Study, initial studies of the RF gun mode-coupling and potential effects on beam dynamics, steady-state studies of FEL-2 performance to 10 nm, preliminary studies of time-dependent FEL-1 performance using electron bunch distribution from the start-to-end studies, and a preliminary investigation of a configuration with FEL sinclined at a small angle from the line of the linac

  18. Automated analysis of whole skeletal muscle for muscular atrophy detection of ALS in whole-body CT images: preliminary study

    Science.gov (United States)

    Kamiya, Naoki; Ieda, Kosuke; Zhou, Xiangrong; Yamada, Megumi; Kato, Hiroki; Muramatsu, Chisako; Hara, Takeshi; Miyoshi, Toshiharu; Inuzuka, Takashi; Matsuo, Masayuki; Fujita, Hiroshi

    2017-03-01

    Amyotrophic lateral sclerosis (ALS) causes functional disorders such as difficulty in breathing and swallowing through the atrophy of voluntary muscles. ALS in its early stages is difficult to diagnose because of the difficulty in differentiating it from other muscular diseases. In addition, image inspection methods for aggressive diagnosis for ALS have not yet been established. The purpose of this study is to develop an automatic analysis system of the whole skeletal muscle to support the early differential diagnosis of ALS using whole-body CT images. In this study, the muscular atrophy parts including ALS patients are automatically identified by recognizing and segmenting whole skeletal muscle in the preliminary steps. First, the skeleton is identified by its gray value information. Second, the initial area of the body cavity is recognized by the deformation of the thoracic cavity based on the anatomical segmented skeleton. Third, the abdominal cavity boundary is recognized using ABM for precisely recognizing the body cavity. The body cavity is precisely recognized by non-rigid registration method based on the reference points of the abdominal cavity boundary. Fourth, the whole skeletal muscle is recognized by excluding the skeleton, the body cavity, and the subcutaneous fat. Additionally, the areas of muscular atrophy including ALS patients are automatically identified by comparison of the muscle mass. The experiments were carried out for ten cases with abnormality in the skeletal muscle. Global recognition and segmentation of the whole skeletal muscle were well realized in eight cases. Moreover, the areas of muscular atrophy including ALS patients were well identified in the lower limbs. As a result, this study indicated the basic technology to detect the muscle atrophy including ALS. In the future, it will be necessary to consider methods to differentiate other kinds of muscular atrophy as well as the clinical application of this detection method for early ALS

  19. Preliminary study on zinc-carbon battery performance by using neutron tomography

    International Nuclear Information System (INIS)

    Abdul Aziz Mohamed; Nor Abidin Ashari; Mohd Zaid Abdullah; Junita Mohamad Saleh; Azraf Azman; Megat Harun AlRashid Megat Ahmad; Rafhayudi Jamro

    2008-08-01

    This paper describes on the discharging characteristic of zinc-carbon batteries (dry cells) by using a neutron imaging technique called a monochromatic neutron tomography. Experiment was conducted on the Nuclear Malaysia neutron tomography prototype instrument which based on 1-dimensional position sensitive neutron detector. The instrument is constructed at the small angle neutron scattering (SANS) beam line built at the one of the beam ports of TRIGA MARK II Research reactor, Malaysian Nuclear Agency, Bangi, Selangor. The main aim of this preliminary experiment was to test the instrument capability on a real industrial component. It was also aimed to understand structural and chemical changes of these battery particles after experiencing a discharging process. In this preliminary work, new and used batteries used were the products of Eveready company. (Author)

  20. Preliminary Study on Earthquake Surface Rupture Extraction from Uav Images

    Science.gov (United States)

    Yuan, X.; Wang, X.; Ding, X.; Wu, X.; Dou, A.; Wang, S.

    2018-04-01

    Because of the advantages of low-cost, lightweight and photography under the cloud, UAVs have been widely used in the field of seismic geomorphology research in recent years. Earthquake surface rupture is a typical seismic tectonic geomorphology that reflects the dynamic and kinematic characteristics of crustal movement. The quick identification of earthquake surface rupture is of great significance for understanding the mechanism of earthquake occurrence, disasters distribution and scale. Using integrated differential UAV platform, series images were acquired with accuracy POS around the former urban area (Qushan town) of Beichuan County as the area stricken seriously by the 2008 Wenchuan Ms8.0 earthquake. Based on the multi-view 3D reconstruction technique, the high resolution DSM and DOM are obtained from differential UAV images. Through the shade-relief map and aspect map derived from DSM, the earthquake surface rupture is extracted and analyzed. The results show that the surface rupture can still be identified by using the UAV images although the time of earthquake elapse is longer, whose middle segment is characterized by vertical movement caused by compression deformation from fault planes.

  1. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  2. Biological image construction by using Raman radiation and Pca: preliminary results

    International Nuclear Information System (INIS)

    Martinez E, J. C.; Cordova F, T.; Hugo R, V.

    2015-10-01

    Full text: In the last years, the Raman spectroscopy (Rs) technique has had some applications in the study and analysis of biological samples, due to it is able to detect concentrations or presence of certain organic and inorganic compounds of medical interest. In this work, raw data were obtained through measurements in selected points on a square regions in order to detect specific organic / inorganic compounds on biological samples. Gold nano stars samples were prepared and coated with membrane markers (CD 10+ and CD 19+) and diluted in leukemic B lymphocytes. Each data block was evaluated independently by the method of principal component analysis (Pca) in order to find representative dimensionless values (Cp) for each Raman spectrum in a specific coordinate. Each Cp was normalized in a range of 0-255 in order to generate a representative image of 8 bits of the region under study. Data acquisition was performed with Raman microscopy system Renishaw in Via in the range of 550 to 1700 cm-1 with a 785 nm laser source, with a power of 17 m W and 15 s of exposure time were used for each spectrum. In preliminary results could detect the presence of molecular markers CD 10+ and CD 19+ with gold nano stars and discrimination between both markers. The results suggest conducting studies with specific concentrations organic and inorganic materials. (Author)

  3. Biological image construction by using Raman radiation and Pca: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Martinez E, J. C. [IPN, Unidad Profesional Interdisciplinaria de Ingenieria, Campus Guanajuato, Av. Mineral de Valenciana 200, Col. Fracc. Industrial Puerto Interior, 36275 Silao, Guanajuato (Mexico); Cordova F, T. [Universidad de Guanajuato, DIC, Departamento de Ingenieria Fisica, Loma del Bosque No. 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Hugo R, V., E-mail: jcmartineze@ipn.mx [Universidad de Guadalajara, Centro Universitario de Tonala, Morelos No. 180, 69584 Tonala, Jalisco (Mexico)

    2015-10-15

    Full text: In the last years, the Raman spectroscopy (Rs) technique has had some applications in the study and analysis of biological samples, due to it is able to detect concentrations or presence of certain organic and inorganic compounds of medical interest. In this work, raw data were obtained through measurements in selected points on a square regions in order to detect specific organic / inorganic compounds on biological samples. Gold nano stars samples were prepared and coated with membrane markers (CD 10+ and CD 19+) and diluted in leukemic B lymphocytes. Each data block was evaluated independently by the method of principal component analysis (Pca) in order to find representative dimensionless values (Cp) for each Raman spectrum in a specific coordinate. Each Cp was normalized in a range of 0-255 in order to generate a representative image of 8 bits of the region under study. Data acquisition was performed with Raman microscopy system Renishaw in Via in the range of 550 to 1700 cm-1 with a 785 nm laser source, with a power of 17 m W and 15 s of exposure time were used for each spectrum. In preliminary results could detect the presence of molecular markers CD 10+ and CD 19+ with gold nano stars and discrimination between both markers. The results suggest conducting studies with specific concentrations organic and inorganic materials. (Author)

  4. Preliminary clinical results: an analyzing tool for 2D optical imaging in detection of active inflammation in rheumatoid arthritis

    Science.gov (United States)

    Adi Aizudin Bin Radin Nasirudin, Radin; Meier, Reinhard; Ahari, Carmen; Sievert, Matti; Fiebich, Martin; Rummeny, Ernst J.; No"l, Peter B.

    2011-03-01

    Optical imaging (OI) is a relatively new method in detecting active inflammation of hand joints of patients suffering from rheumatoid arthritis (RA). With the high number of people affected by this disease especially in western countries, the availability of OI as an early diagnostic imaging method is clinically highly relevant. In this paper, we present a newly in-house developed OI analyzing tool and a clinical evaluation study. Our analyzing tool extends the capability of existing OI tools. We include many features in the tool, such as region-based image analysis, hyper perfusion curve analysis, and multi-modality image fusion to aid clinicians in localizing and determining the intensity of inflammation in joints. Additionally, image data management options, such as the full integration of PACS/RIS, are included. In our clinical study we demonstrate how OI facilitates the detection of active inflammation in rheumatoid arthritis. The preliminary clinical results indicate a sensitivity of 43.5%, a specificity of 80.3%, an accuracy of 65.7%, a positive predictive value of 76.6%, and a negative predictive value of 64.9% in relation to clinical results from MRI. The accuracy of inflammation detection serves as evidence to the potential of OI as a useful imaging modality for early detection of active inflammation in patients with rheumatoid arthritis. With our in-house developed tool we extend the usefulness of OI imaging in the clinical arena. Overall, we show that OI is a fast, inexpensive, non-invasive and nonionizing yet highly sensitive and accurate imaging modality.-

  5. Preliminary studies of monoclonal antibody lymphoscintigraphy in malignant melanoma

    International Nuclear Information System (INIS)

    Nelp, W.B.; Eary, J.F.; Jones, R.F.; Hellstrom, K.E.; Hellstrom, I.; Beaumier, P.L.; Krohn, K.A.

    1987-01-01

    Lymphoscintigraphy was performed at 3 and 20 hr following subcutaneous injection of 131 I anti-melanoma antibody (Fab) in 11 patients who had surgical resection of lymph nodes (neck, axilla, groin) at 24 hr for suspected metastatic melanoma. Comparable amounts of 125 I nonspecific control antibody (Fab) were co-administered. Six patients had nodal metastases and three showed positive images at both time periods. Five patients had no metastases though one was image positive. Four other nondiseased inguinal node groups were image negative. A total of 28 tumored nodes and 110 normal nodes were removed, counted and histologically examined. All metastatic tumors expressed antigen against which the specific Fab was directed. The concentrations of both specific and nonspecific Fab were similar in tumored nodes and both were significantly greater than in normal nodes showed essentially identical intranodal spatial distribution of the specific and control Fab in areas containing tumor. These preliminary results suggest the increased concentration of murine immunoglobulin (Fab) retained in diseased nodes was a nonspecific phenomenon

  6. Cognitive impairment and computer tomography image in patients with arterial hypertension -preliminary results

    International Nuclear Information System (INIS)

    Yaneva-Sirakova, T.; Tarnovska-Kadreva, R.; Traykov, L.; Zlatareva, D.

    2012-01-01

    Arterial hypertension is the leading risk factor for cognitive impairment, but it is developed only in some of the patients with pour control. On the other hand, not all of the patents with white matter changes have cognitive deficit. There may be a variety of reasons for this: the accuracy of methods for blood pressure measurement, the specific brain localization or some other reason. Here are the preliminary results of a study (or the potential correlation between self-measured, office-, ambulatory monitored blood pressure, central aortic blood pressure, minimal cognitive impairment and the specific brain image on contrast computer tomography. We expect to answer, the question whether central aortic or self-measured blood pressure have the leading role for the development of cognitive impairment in the presence of a specific neuroimaging finding, as well as what is the prerequisite for the clinical manifestation of cognitive dysfunction in patients with computer tomographic pathology. (authors)

  7. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy.

    Science.gov (United States)

    Massey, Michael J; Larochelle, Ethan; Najarro, Gabriel; Karmacharla, Adarsh; Arnold, Ryan; Trzeciak, Stephen; Angus, Derek C; Shapiro, Nathan I

    2013-12-01

    Side-stream dark-field microscopy is currently used to directly visualize sublingual microcirculation at the bedside. Our experience has found inherent technical challenges in the image acquisition process. This article presents and assesses a quality assurance method to rate image acquisition quality before analysis. We identified 6 common image capture and analysis problem areas in sublingual side-stream dark-field videos: illumination, duration, focus, content, stability, and pressure. We created the "Microcirculation Image Quality Score" by assigning a score of optimal (0 points), suboptimal but acceptable (1 point), or unacceptable (10 points) to each category (for further details, go to http://www.MicroscanAnalysis.blogspot.com). We evaluated 59 videos from a convenience sample of 34 unselected, noncritically ill emergency department patients to create a test set. Two raters, blinded to each other, implemented the score. Any video with a cumulative score of 10 or higher (range, 0-60) was considered unacceptable for further analysis. We created the Microcirculation Image Quality Score and applied it to 59 videos. For this particular set of 59 videos, the mean (SD) passing quality score was 1.68 (0.90), and the mean (SD) failing quality score was 15.74 (6.19), with 27 of 59 passing the quality score less than 10. Highest failure occurred from pressure artifact. The interrater agreement for acceptability was assessed using Cohen κ for each category: illumination (κ = 1.0), duration (κ = 1.0), focus (κ = 0.91), content (κ = 0.76), stability (κ = 0.71), and pressure (κ = 0.82) and overall pass-fail rates (score >10) (κ = 0.66). Our Microcirculation Image Quality Score addresses many of the common areas where video quality can degrade. The criteria introduced are an objective way to assess the quality of image acquisition, with the goal of selecting videos of adequate quality for analysis. The interrater reliability results in our preliminary study suggest

  8. Preliminary Results of Nuclear Fluorescence Imaging of Alpha and Beta Emitting Sources

    International Nuclear Information System (INIS)

    Feener, Jessica S.; Charlton, William S.

    2013-06-01

    The preliminary results from a series of nuclear fluorescence imaging experiments using a variety of radioactive sources and shielding are given. These experiments were done as part of a proof of concept to determine if nuclear fluorescence imaging could be used as a safeguards measurements tool or for nuclear warhead verification for nuclear arms control treaties such as the New Strategic Arms Reduction Treaty and the Fissile Material Cut-Off Treaty. An off-the-shelf Princeton Instruments charged coupled device camera system was used to image the emission of fluorescence photons from the de-excitation of nitrogen molecules in air that have been excited by ionizing radiation. The fluorescence emissions are primarily in the near ultraviolet range; between the wavelengths of 300 and 400 nm. Fluorescent imaging techniques are currently being investigated in a number of applications. A French research team has successfully demonstrated this concept for remote imaging of alpha contamination. It has also been shown that the phenomenon can be seen through translucent materials and that alpha radiation can be seen in the presence of large gamma backgrounds. Additionally, fluorescence telescopes and satellites utilize the de-excitation of nitrogen molecules to observe cosmic ray showers in the atmosphere. In cosmic ray shower detection, electrons are the main contributor to the excitation of the of nitrogen molecules in air. The experiments presented in this paper were designed to determine if the imaging system could observe beta emitting sources, differentiate between beta emitters and alpha emitting materials such as uranium oxide and uranium metal, and to further investigate the phenomenon through translucent and non-translucent materials. The initial results show that differentiation can be made between beta and alpha emitting sources and that the device can observe the phenomenon through very thin non-transparent material. Additionally, information is given on the

  9. A compact hard X-ray source for medical imaging and biomolecular studies

    International Nuclear Information System (INIS)

    Cline, D.B.; Green, M.A.; Kolonko, J.

    1995-01-01

    There are a large number of synchrotron light sources in the world. However, these sources are designed for physics, chemistry, and engineering studies. To our knowledge, none have been optimized for either medical imaging or biomolecular studies. There are special needs for these applications. We present here a preliminary design of a very compact source, small enough for a hospital or a biomolecular laboratory, that is suitable for these applications. (orig.)

  10. A preliminary investigation: the impact of microscopic condenser on depth of field in cytogenetic imaging

    Science.gov (United States)

    Ren, Liqiang; Qiu, Yuchen; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Wei R.; Liu, Hong

    2013-02-01

    As one of the important components of optical microscopes, the condenser has a considerable impact on system performance, especially on the depth of field (DOF). DOF is a critical technical feature in cytogenetic imaging that may affect the efficiency and accuracy of clinical diagnosis. The purpose of this study is to investigate the influence of microscopic condenser on DOF using a prototype of transmitted optical microscope, based on objective and subjective evaluations. After the description of the relationship between condenser and objective lens and the theoretical analysis of the condenser impact on system numerical aperture and DOF, a standard resolution pattern and several cytogenetic samples are adopted to assess the condenser impact on DOF, respectively. The experimental results of these objective and subjective evaluations are in agreement with the theoretical analysis and show that, under the specific intermediate range of condenser numerical aperture ( NAcond ), the DOF value decreases with the increase of NAcond . Although the above qualitative results are obtained under the experimental conditions with a specific prototype system, the methods presented in this preliminary investigation could offer useful guidelines for optimizing operational parameters in cytogenetic imaging.

  11. Preliminary clinical study of 99Tcm-HL91 imaging in bone metastasis

    International Nuclear Information System (INIS)

    Liu Baoping; Mao Ronghu; Han Xingmin

    2008-01-01

    Objective: 99 Tc m -4, 9-diaza-3, 3, 10, 10-tetramethyldodecan-2, 11-dione dioxime (HL91), a new type of hypoxic agents, accumulates in tumor hypoxic tissue specifically. The aim of this study was to evaluate the value of 99 Tc m -HL91 imaging in the diagnosis of bone metastasis. Methods: Nine- teen cases with bone metastasis (without any treatment) and 8 cases with benign lesions underwent SPECT imaging at 4 h after injection of 740 MBq of 99 Tc m -HL91 along with 99 Tc m -methylene diphosphonic acid (MDP) imaging. Regions of interest (ROIs) were drawn in tumor tissue and contralateral normal tissue respectively, and the radioactivity ratios of tumor-to-normal (T/N) were calculated. The t-test was used for data analysis with SPSS 11.0. Results: There were visible uptake of 99 Tc m -HL91 in 79 out of 85 focuses in 19 patients of bone metastasis; however, there was no obvious uptake of 99 Tc m -HL91 in 12 focuses of 8 patients of benign lesions. Significant difference existed between the T/N values of malignant (1.877 ± 0.288) and benign lesions [(0.735 ± 0.236); t=13.065, P 0.05). Conclusion: The results indicated that 99 Tc m -HL91 was useful in diagnosing the malignant and benign bone lesions. (authors)

  12. Imaging-Guided Percutaneous Radiofrequency Ablation of Adrenal Metastases: Preliminary Results at a Single Institution with a Single Device

    International Nuclear Information System (INIS)

    Carrafiello, G.; Lagana, D.; Recaldini, C.; Giorgianni, A.; Ianniello, A.; Lumia, D.; D'Ambrosio, A.; Petulla, M.; Dionigi, G.; Fugazzola, C.

    2008-01-01

    The aim of this study was to show the feasibility, safety, imaging appearance, and short-term efficacy of image-guided percutaneous radiofrequency ablation (RFA) of adrenal metastases (AM). Seven imaging-guided percutaneous RFA treatments were performed in six patients (two men and four women; mean age, 67.2 years; range, 55-74 years) with six AM who were referred to our institution from 2003 to 2006. One patient was treated twice for recurrence after first treatment. The average diameter of the treated AM was 29 mm (range, 15-40 mm). In all patients, the diagnosis was obtained with CT current protocols in use at our institution and confirmed by pathology with an image-guided biopsy. No major complications occurred. In one patient shortly after initiation of the procedure, severe hypertension was noted; another patient developed post-RFA syndrome. In five of six lesions, there was no residual enhancement of the treated tumor. In one patient CT examination showed areas of residual enhancement of the tumor after treatment. Our preliminary results suggest that imaging-guided percutaneous RFA is effective for local control of AM, without major complications and with a low morbidity rate related to the procedure. Long-term follow-up will need to be performed and appropriate patient selection criteria will need to be determined in future randomized trials.

  13. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  14. Method of preliminary localization of the iris in biometric access control systems

    Science.gov (United States)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  15. 123I-tyrosine-(A14)-insulin: preparation and preliminary clinical studies

    International Nuclear Information System (INIS)

    Pantev, T.; Virgolini, I.; Sinzinger, H.; Prager, R.; Neuhold, N.; Angelberger, P.; Banyai, M.; Knoebl, P.; Vienna Univ.

    1991-01-01

    Insulin was radioiodinated with 123 I ( 123 I-tyrosine-(A14)-insulin) to a specific activity of 1 μg/mCi, corresponding to 0.025 I.U. of insulin/mCi. This preparation was used for in vitro binding experiments with adipose tissue, showing active binding to the two subunits of the known insulin receptor. In a preliminary clinical investigation, 5 adipose patients with (n = 2) and without (n = 3) diabetes mellitus Type II, were subject to in vivo injection of the same radiolabeled product using 3 mCi/patient. During the first minutes of dynamic imaging, the liver was the major organ of tracer uptake in all patients. Furthermore, the pancreas, and in one patient the kidneys, were visualised. Further studies on insulin in vivo kinetics and quantification are under way. (authors)

  16. Imaging Arterial Fibres Using Diffusion Tensor Imaging—Feasibility Study and Preliminary Results

    Directory of Open Access Journals (Sweden)

    Kerskens Christian

    2010-01-01

    Full Text Available Abstract MR diffusion tensor imaging (DTI was used to analyze the fibrous structure of aortic tissue. A fresh porcine aorta was imaged at 7T using a spin echo sequence with the following parameters: matrix 128 128 pixel; slice thickness 0.5 mm; interslice spacing 0.1 mm; number of slices 16; echo time 20.3 s; field of view 28 mm 28 mm. Eigenvectors from the diffusion tensor images were calculated for the central image slice and the averaged tensors and the eigenvector corresponding to the largest eigenvalue showed two distinct angles corresponding to near and to the transverse plane of the aorta. Fibre tractography within the aortic volume imaged confirmed that fibre angles were oriented helically with lead angles of and . The findings correspond to current histological and microscopy data on the fibrous structure of aortic tissue, and therefore the eigenvector maps and fibre tractography appear to reflect the alignment of the fibers in the aorta. In view of current efforts to develop noninvasive diagnostic tools for cardiovascular diseases, DTI may offer a technique to assess the structural properties of arterial tissue and hence any changes or degradation in arterial tissue.

  17. Predicting visual semantic descriptive terms from radiological image data: preliminary results with liver lesions in CT.

    Science.gov (United States)

    Depeursinge, Adrien; Kurtz, Camille; Beaulieu, Christopher; Napel, Sandy; Rubin, Daniel

    2014-08-01

    We describe a framework to model visual semantics of liver lesions in CT images in order to predict the visual semantic terms (VST) reported by radiologists in describing these lesions. Computational models of VST are learned from image data using linear combinations of high-order steerable Riesz wavelets and support vector machines (SVM). In a first step, these models are used to predict the presence of each semantic term that describes liver lesions. In a second step, the distances between all VST models are calculated to establish a nonhierarchical computationally-derived ontology of VST containing inter-term synonymy and complementarity. A preliminary evaluation of the proposed framework was carried out using 74 liver lesions annotated with a set of 18 VSTs from the RadLex ontology. A leave-one-patient-out cross-validation resulted in an average area under the ROC curve of 0.853 for predicting the presence of each VST. The proposed framework is expected to foster human-computer synergies for the interpretation of radiological images while using rotation-covariant computational models of VSTs to 1) quantify their local likelihood and 2) explicitly link them with pixel-based image content in the context of a given imaging domain.

  18. Measurement of small bowel transit time by 99Tcm-SC imaging: preliminary clinical study

    International Nuclear Information System (INIS)

    Zhang Shaohua; Xu Jingying; Bei Lian; Zhu Chaohui; Ba Jiantao

    1999-01-01

    Objective: To develop a method of measuring small bowel transit time (SBTT) by 99 Tc m -sulfur collide (SC) imaging and to compare with the method of added lactose in the test meal. Methods: 20 healthy volunteers and 26 patients with gastrointestinal disorders were studied. In fasting state, the subjects were asked to ingest the 99 Tc m -SC labelled solid meal within 5 minutes, then the image acquisition was immediately started with SPECT. The images were acquired every 15 min during the first hour, at 30 min intervals during 2∼4 hours and hourly thereafter until 80% radioactivity had entered the colon. One week later, the same procedure of imaging with 15 g lactulose added in the test meal was performed. The regions of interest (ROIs) were taken at stomach and colon, and the SBTT was calculated by deconvolution or by subtraction of the 50% time of gastric emptying from the 50% time of colon filling. Results: 1) The mean SBTT of 20 healthy volunteers was (4.2 +- 0.5) h, oral-caecum transit time (OCTT) was (4.3 +- 0.6) h; lactulose shortened the SBTT by (1.8 +- 0.6) h; 2) 26 patients showed different results of SBTT due to their different gastrointestinal disorders bases. Conclusions: 99 Tc m -SC imaging was a noninvasive and useful method to measure SBTT. The added lactulose can shorten the examination time and help to identify the time of food to the ileocecal region

  19. Preliminary test of an imaging probe for nuclear medicine using hybrid pixel detectors

    International Nuclear Information System (INIS)

    Bertolucci, E.; Maiorino, M.; Mettivier, G.; Montesi, M.C.; Russo, P.

    2002-01-01

    We are investigating the feasibility of an intraoperative imaging probe for lymphoscintigraphy with Tc-99m tracer, for sentinel node radioguided surgery, using the Medipix series of hybrid detectors coupled to a collimator. These detectors are pixelated semiconductor detectors bump-bonded to the Medipix1 photon counting read-out chip (64x64 pixel, 170 μm pitch) or to the Medipix2 chip (256x256 pixel, 55 μm pitch), developed by the European Medipix collaboration. The pixel detector we plan to use in the final version of the probe is a semi-insulating GaAs detector or a 1-2 mm thick CdZnTe detector. For the preliminary tests presented here, we used 300-μm thick silicon detectors, hybridized via bump-bonding to the Medipix1 chip. We used a tungsten parallel-hole collimator (7 mm thick, matrix array of 64x64 100 μm circular holes with 170 μm pitch), and a 22, 60 and 122 keV point-like (1 mm diameter) radioactive sources, placed at various distances from the detector. These tests were conducted in order to investigate the general feasibility of this imaging probe and its resolving power. Measurements show the high resolution but low efficiency performance of the detector-collimator set, which is able to image the 122 keV source with <1 mm FWHM resolution

  20. Hyperpolarized 3He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Mathew, Lindsay; Kirby, Miranda; Etemad-Rezai, Roya; Wheatley, Andrew; McCormack, David G.; Parraga, Grace

    2011-01-01

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ( 3 He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for 3 He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, 1 H MRI and hyperpolarized 3 He MRI at 3.0 T. 3 He ventilation defect percent (VDP) was generated from 3 He static ventilation images and 1 H thoracic images and the 3 He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant 3 He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for 3 He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  1. Quantitative imaging of the human upper airway: instrument design and clinical studies

    Science.gov (United States)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  2. Ultrasonic propulsion of kidney stones: preliminary results of human feasibility study.

    Science.gov (United States)

    Bailey, Michael; Cunitz, Bryan; Dunmire, Barbrina; Paun, Marla; Lee, Franklin; Ross, Susan; Lingeman, James; Coburn, Michael; Wessells, Hunter; Sorensen, Mathew; Harper, Jonathan

    2014-09-03

    One in 11 Americans has experienced kidney stones, with a 50% average recurrence rate within 5-10 years. Ultrasonic propulsion (UP) offers a potential method to expel small stones or residual fragments before they become a recurrent problem. Reported here are preliminary findings from the first investigational use of UP in humans. The device uses a Verasonics ultrasound engine and Philips HDI C5-2 probe to generate real-time B-mode imaging and targeted "push" pulses on demand. There are three arms of the study: de novo stones, post-lithotripsy fragments, and the preoperative setting. A pain questionnaire is completed prior to and following the study. Movement is classified based on extent. Patients are followed for 90 days. Ten subjects have been treated to date: three de novo , five post-lithotripsy, and two preoperative. None of the subjects reported pain associated with the treatment or a treatment related adverse event, beyond the normal discomfort of passing a stone. At least one stone was moved in all subjects. Three of five post-lithotripsy subjects passed a single or multiple stones within 1-2 weeks following treatment; one subject passed two (1-2 mm) fragments before leaving clinic. In the pre-operative studies we successfully moved 7 - 8 mm stones. In four subjects, UP revealed multiple stone fragments where the clinical image and initial ultrasound examination indicated a single large stone.

  3. The preliminary study of CT cerebral perfusion imaging in transient ischemic attacks

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Du Xiangying

    2002-01-01

    Objective: To probe the application of CT cerebral perfusion imaging on transient ischemic attacks (TIA). Methods: Conventional CT and CT cerebral perfusion imaging were performed on 5 normal adults and 20 patients with clinically diagnosed TIA. After regular CT examination, dynamic scans of 40 seconds were performed on selected slice (usually on the basal ganglia slice), while 40 ml non-ionic contrast material were bolus injected through antecubital vein with. These dynamic images were processed with the 'Perfusion CT' software package on a PC based workstation. Cerebral blood flow (CBF) and time to peak (TP) enhancement were measured within specific regions of the brain on CT perfusion images. Quantitative analysis was performed for these images. Results: A gradient of perfusion between gray matter and white matter was showed on cT perfusion images in normal adults and TIA patients. CBF and TP for normal cortical and white matter were 378.2 ml·min -1 ·L -1 , 7.8 s and 112.5 ml·min -1 ·L -1 , 9.9 s, respectively. In 20 cases with TIA, persisting abnormal perfusion changes corresponding to clinical symptoms were found in 15 cases with prolonged TP. Other 5 cases showed normal results. TP of affected side (11.8 +- 4.4) s compared with that of the contralateral side (9.1 +- 3.1) s was significantly prolonged (t = 5.277, P -1 · -1 ] and contralateral side [(229.1 +- 41.4) ml·min -1 ·L -1 ]. Conclusion: Perfusion CT provides valuable hemodynamic information and shows the extent of perfusion disturbances for patients with TIA

  4. Imaging Arterial Fibres Using Diffusion Tensor Imaging—Feasibility Study and Preliminary Results

    Directory of Open Access Journals (Sweden)

    Ciaran K. Simms

    2010-01-01

    Full Text Available MR diffusion tensor imaging (DTI was used to analyze the fibrous structure of aortic tissue. A fresh porcine aorta was imaged at 7T using a spin echo sequence with the following parameters: matrix 128 × 128 pixel; slice thickness 0.5 mm; interslice spacing 0.1 mm; number of slices 16; echo time 20.3 s; field of view 28 mm × 28 mm. Eigenvectors from the diffusion tensor images were calculated for the central image slice and the averaged tensors and the eigenvector corresponding to the largest eigenvalue showed two distinct angles corresponding to near 0∘ and 180∘ to the transverse plane of the aorta. Fibre tractography within the aortic volume imaged confirmed that fibre angles were oriented helically with lead angles of 15±2.5∘ and 175±2.5∘. The findings correspond to current histological and microscopy data on the fibrous structure of aortic tissue, and therefore the eigenvector maps and fibre tractography appear to reflect the alignment of the fibers in the aorta. In view of current efforts to develop noninvasive diagnostic tools for cardiovascular diseases, DTI may offer a technique to assess the structural properties of arterial tissue and hence any changes or degradation in arterial tissue.

  5. Early signs of osteoarthritis in professional ballet dancers: a preliminary study.

    Science.gov (United States)

    Angioi, Manuela; Maffulli, Gayle D; McCormack, Moira; Morrissey, Dylan; Chan, Otto; Maffulli, Nicola

    2014-09-01

    To investigate a cohort of professional ballet dancers for evidence of early signs of osteoarthritis (OA). One radiologist and 1 orthopedic surgeon specialized in musculoskeletal disorders analyzed magnetic resonance imaging scans independently. University Teaching Hospital. Fifteen professional ballet dancers (4 males and 11 females; age range, 19-36 years) experiencing chronic pain in the hip, knee, spine, ankle, or foot joints. Presence of osteophytes, subchondral sclerosis, joint space narrowing, cysts, and bone marrow changes; the Kellgren and Lawrence scale was used to quantify the knee OA. In the knee, there was thinning and irregularity of the articular cartilage over the medial femoral condyle and bone marrow changes within the lateral femoral condyle. In the hip, there was a loss of joint space and a frayed labrum with deep recess. The first metatarsophalangeal joint showed evidence of osteophytic development. Early signs of OA, in different joints, were present in a small but highly selected cohort of professional ballet dancers. In future, prospective studies among a number of ballet companies should control for medical and natural history alongside the visual analysis of images and plain radiographs to confirm these preliminary results.

  6. Preliminary study of mercury target structure

    Energy Technology Data Exchange (ETDEWEB)

    Kaminaga, Masanori; Haga, Katsuhiro; Hino, Ryutaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kumasaka, Katsuyuki; Uchida, Shoji; Nakagawa, Toshi; Mori, Seiji; Nishikawa, Akira

    1997-11-01

    Development of a proton accelerator based neutron source (1.5 GeV, 5.3 mA (for neutron source 3.3 mA), thermal power 8 MW) is currently conducted by the Special Task Force for Neutron Science Initiative, JAERI. Preliminary design studies and related R and D of a solid metal target for the first stage (1.5 GeV, 1 mA) and a liquid metal target for both the first and second stages (1.5 GeV, 3.3 mA) are conducted by the Target Group to develop both solid and liquid metal target systems. A few kinds of target structures have been investigated in FY 1996 and the preliminary results for the target structures are described in this paper. Investigation results of alternative materials for the target container are also described in this paper. (author)

  7. Correlation of ultrasound imaging of oral swallow with ventilatory alterations in cerebral palsied and normal children: preliminary observations.

    Science.gov (United States)

    Kenny, D J; Casas, M J; McPherson, K A

    1989-01-01

    Preliminary results of an investigation that synchronizes the videotaped output of ultrasound camera and the analog data from physiological measurements of swallowing and ventilation in normal and cerebral palsied (CP) children are presented. Four cerebral palsied children and three control children undertook a single sip-swallow of 5 ml of liquid and a solid mastication-swallow sequence on three occasions according to a defined protocol. The CP children exhibited much more variability and less control of the liquid bolus than did the controls. The ultrasound image clearly demonstrates the lack of control of the posterior of the tongue in many CP children. Some parts of the sequence of oral swallow and the time to achieve maximum anterior displacement of the hyoid bone appear to be slowed. The sequential events of swallowing show less variability as the sip-swallow proceeds from the oral voluntary to pharyngeal and lower involuntary phases. This study also identified a short-latency apnea that appears to accompany a saliva (protective) swallow and a long-latency apnea that accompanies semi-solid or liquid bolus (alimentary) swallows. Further investigations of normal and CP children utilizing a combined diagnostic imaging-physiological measurement approach will follow this initial study.

  8. A high resolution chromosome image processor for study purposes, NIRS-1000:CHROMO STUDY, and algorithm developing to classify radiation induced aberrations.

    Science.gov (United States)

    Yamamoto, M; Hayata, I; Furuta, S

    1992-03-01

    Since 1989 we have promoted a project to develop an automated scoring system of radiation induced chromosome aberrations. As a first step, a high resolution image processing system for study purposes, NIRS-1000:CHROMO STUDY, has been developed. It is composed of: (1) CHROMO MARKER whose main purpose is to mark on images to make image data base, (2) CHROMO ALGO whose purpose is algorithm development, and (3) METAPHASE RANKER whose purposes are metaphase finding and ranking with a high power objective lens. However, METAPHASE RANKER is presently under development. The system utilizes a high definition video system so as to realize the best spatial resolution that is achievable with an optical microscope using an objective lens (x 100, numerical aperture 1.4). The video camera has 1024 effective scan lines to realize 0.1 microns sampling on a specimen. The system resolution achieved on the hard copy is less than 0.3 microns on a specimen. A preliminary algorithm has been developed to classify the aberrations on the system using projection information of gray level. The preliminary test results on excellent 10 metaphases show that the correct classification ratio is 92.7%, that the detection rate of the aberrations is 83.3% and that the false positive rate is 6.1%.

  9. Preliminary diffusion tensor imaging studies in limb-girdle muscular dystrophies

    Science.gov (United States)

    Hidalgo-Tobon, S.; Hernandez-Salazar, G.; Vargas-Cañas, S.; Marrufo-Melendez, O.; Solis-Najera, S.; Taboada-Barajas, J.; Rodriguez, A. O.; Delgado-Hernandez, R.

    2012-10-01

    Limb-girdle muscular dystrophies (LGMD) are a group of autosomal dominantly or recessively inherited muscular dystrophies that also present with primary proximal (limb-girdle) muscle weakness. This type of dystrophy involves the shoulder and pelvic girdles, distinct phenotypic or clinical characteristics are recognized. Imaging experiments were conducted on a 1.5T GE scanner (General Electric Medical Systems. Milwaukee. USA), using a combination of two eight-channel coil array. Diffusion Tensor Imaging (DTI) data were acquired using a SE-EPI sequence, diffusion weighted gradients were applied along 30 non-collinear directions with a b-value=550 s/mm2. The connective tissue content does not appear to have a significant effect on the directionality of the diffusion, as assessed by fractional anisotropy. The fibers of the Sartorius muscle and gracilis showed decreased number of tracts, secondary to fatty infiltration and replacement of connective tissue and muscle mass loss characteristic of the underlying pathology. Our results demonstrated the utility of non-invasive MRI techniques to characterize the muscle pathology, through quantitative and qualitative methods such as the FA values and tractrography.

  10. High-intensity focused ultrasound treatment of placenta accreta after vaginal delivery: a preliminary study.

    Science.gov (United States)

    Bai, Y; Luo, X; Li, Q; Yin, N; Fu, X; Zhang, H; Qi, H

    2016-04-01

    To evaluate the safety and efficiency of high-intensity focused ultrasound (HIFU) in the treatment of placenta accreta after vaginal delivery. Enrolled into this study between September 2011 and September 2013 were 12 patients who had been diagnosed with placenta accreta following vaginal delivery and who had stable vital signs. All patients were treated using an ultrasound-guided HIFU treatment system. As indication of the effectiveness of the treatment we considered decreased vascular index on color Doppler imaging, decrease in size of residual placenta compared with pretreatment size on assessment by three-dimensional ultrasound with Virtual Organ Computer-aided Analysis, reduced signal intensity and degree of enhancement on magnetic resonance imaging and avoidance of hysterectomy following treatment. To assess the safety of HIFU treatment, we recorded side effects, hemorrhage, infection, sex steroid levels, return of menses and subsequent pregnancy. Patients were followed up in this preliminary study until December 2013. The 12 patients receiving HIFU treatment had an average postpartum hospital stay of 6.8 days and an average period of residual placental involution of 36.9 days. HIFU treatment did not apparently increase the risk of infection or hemorrhage and no patient required hysterectomy. In all patients menstruation recommenced after an average of 80.2 days, and sex steroid levels during the middle luteal phase of the second menstrual cycle were normal. Two patients became pregnant again during the follow-up period. This preliminary study suggests that ultrasound-guided HIFU is a safe and effective non-invasive method to treat placenta accreta patients after vaginal delivery who have stable vital signs and desire to preserve fertility. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  11. Terahertz pulse imaging for tree-ring analysis: a preliminary study for dendrochronology applications

    International Nuclear Information System (INIS)

    Jackson, J B; Mourou, M; Whitaker, J F; Labaune, J; Mourou, G A; Duling, I N III; Williamson, S L; Lavier, C; Menu, M

    2009-01-01

    Time-domain terahertz reflection imaging is presented as a novel method of measuring otherwise inaccessible tree rings in wooden cultural heritage for the purpose of tree-ring crossdating. Axial and lateral two-dimensional terahertz images of obscured ring patterns are statistically validated with respect to their corresponding optical photographs via adapted dendrochronological methods. Results are compared to similar analysis of x-ray images of a wood specimen

  12. Preliminary studies in rice-fish culture in a rainfed lowland ecology ...

    African Journals Online (AJOL)

    Preliminary studies in rice-fish culture in a rainfed lowland ecology in Ghana. PKA Dartey, RK Bam, J Ofori. Abstract. Mixed farms of rice and fish are yet to receive attention in Ghana, despite lowland rice being grown under inundation in most areas nationwide. In a preliminary study, Nile tilapia (Oreochromis niloticus) was ...

  13. Preliminary study of metabolic radiotherapy with 188Re via small animal imaging

    International Nuclear Information System (INIS)

    Antoccia, A.; Baldazzi, G.; Bello, M.

    2006-01-01

    188 Re is a β - (Emax=2.12 MeV) and γ (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, 99m Tc, molecules of hyaluronic acid (HA) have been labelled with 188 Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm 3 pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of 188 Re and with C57 black mice injected with the 188 Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal projections simultaneously we are building in parallel two new cameras to be positioned at 90 degrees. They use a CsI(Tl) matrix with 1x1x5 mm 3 pixels read out by H8500 Hamamatsu Flat panel PMT

  14. Digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Myerowitz, P.D.; Mistretta, C.A.; Shaw, C.-G.; Van Lysel, M.S.; Swanson, D.K.; Lasser, T.A.; Dhanani, S.P.; Zarnstorff, W.C.; Vander Ark, C.R.; Dobbins, J.T.; Peppler, W.W.; Crummy, A.B.

    1982-01-01

    The authors have previously reported on real time digital fluoroscopic subtraction techniques developed in the laboratory during the past 10 years. This paper outlines basic apparatus configuration and imaging modes used for preliminary studies involving visualization of the canine and human heart. All of the techniques involve the use of real time digital subtraction processing of data from an image intensified television fluoroscopy system. Based on the configuration of the digital processing equipment a number of different imaging modalities are possible. A brief description of the apparatus and these imaging modes is given. (Auth.)

  15. Imaging cerebral activity in recovery from chronic traumatic brain injury: a preliminary report.

    Science.gov (United States)

    Lewis, David H; Bluestone, Judith P; Savina, Maryann; Zoller, William H; Meshberg, Emily B; Minoshima, Satoshi

    2006-07-01

    People in chronic phase of traumatic brain injury (TBI) are often told that there will be no further recovery in brain function, that they are in a "static phase." Holistic Approach to NeuroDevelopment and Learning Efficiency (HANDLE), an alternative therapy, aims to improve function by teaching a series of physical and mental activities that clients perform and encouraging changes in lifestyle. Five subjects (3 males) with chronic TBI (at least 3 years since ictus) completed the HANDLE Institute's program and were prospectively evaluated. Each had six regional cerebral blood flow (rCBF) single-photon emission computed tomography (SPECT) scans over 7 months (scans n= 30). Paired scans were performed with injection of Tc-99m ECD to image rCBF at rest and during the HANDLE "Crossed Arm Bounce" (CAB) exercise before the program, at 3-4 months into the program, and at 6-7 months, after the program had ended. SPECT images were analyzed statistically using Neurostat in which image sets were coregistered and warped into Talaraich atlas for pairwise subtraction between conditions. Group analysis of SPECT showed that CAB activated (increased rCBF) vermis and cerebellar hemispheres in first two paired scans and anterior cingulate and vermis on the final pair. Increased rCBF at rest occurred in cerebellar hemispheres, vermis, and right dorsomedial frontal cortex. These preliminary observations suggest that there may be a role of the hindbrain (vermis and cerebellum) with HANDLE treatment of chronic TBI.

  16. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  17. Functional magnetic resonance imaging in disorders of consciousness: preliminary results of an innovative analysis of brain connectivity.

    Science.gov (United States)

    De Pasquale, Francesco; Caravasso, Chiara Falletta; Péran, Patrice; Catani, Sheila; Tuovinen, Noora; Sabatini, Umberto; Formisano, Rita

    2015-01-01

    The aim of this preliminary study was to present a new approach for connectivity analysis in patients with severe acquired brain injury (ABI) that overcomes some of the difficulties created by anatomical abnormalities due to the brain injury. Using a data-driven approach, resting-state structural MRI (sMRI) and functional MRI (fMRI) data from three severe ABI patients - two with disorders of consciousness (DOC) and one who had recovered consciousness (non-DOC) - were integrated and analyzed. Parameters extracted from the distribution of the connectivity values, such as mean, standard deviation and skeweness, were considered. The distribution parameters estimated seem to provide an accurate multivariate classification of the considered cases that can be summarized as follows: connectivity in the severe ABI patients with DOC was on average lower than in the severe ABI non-DOC patient and healthy subjects. The dispersion of connectivity values of the severe ABI patients, non-DOC and DOC, was comparable, however the shape of the distribution was different in the non-DOC patient. Eventually, seed-based connectivity maps of the default mode Functional magnetic resonance imaging in disorders of consciousness: preliminary results of an innovative analysis of brain connectivity network show a pattern of increasing disruption of this network from the healthy subjects to non-DOC and DOC patients. Consistent results are obtained using an ICA-based approach..

  18. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  19. Hyperpolarized {sup 3}He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Lindsay, E-mail: lmathew@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Kirby, Miranda, E-mail: mkirby@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Etemad-Rezai, Roya, E-mail: Roya.EtemadRezai@lhsc.on.ca [Department of Medical Imaging, University of Western Ontario (Canada); Wheatley, Andrew, E-mail: awheat@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); McCormack, David G., E-mail: David.McCormack@lhsc.on.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Division of Respirology, Department of Medicine, University of Western Ontario, London (Canada); Lawson Health Research Institute, London (Canada); Parraga, Grace, E-mail: gep@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Department of Medical Imaging, University of Western Ontario (Canada); Lawson Health Research Institute, London (Canada)

    2011-07-15

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ({sup 3}He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for {sup 3}He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, {sup 1}H MRI and hyperpolarized {sup 3}He MRI at 3.0 T. {sup 3}He ventilation defect percent (VDP) was generated from {sup 3}He static ventilation images and {sup 1}H thoracic images and the {sup 3}He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant {sup 3}He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for {sup 3}He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  20. Applying Data-driven Imaging Biomarker in Mammography for Breast Cancer Screening: Preliminary Study

    OpenAIRE

    Kim, Eun-Kyung; Kim, Hyo-Eun; Han, Kyunghwa; Kang, Bong Joo; Sohn, Yu-Mee; Woo, Ok Hee; Lee, Chan Wha

    2018-01-01

    We assessed the feasibility of a data-driven imaging biomarker based on weakly supervised learning (DIB; an imaging biomarker derived from large-scale medical image data with deep learning technology) in mammography (DIB-MG). A total of 29,107 digital mammograms from five institutions (4,339 cancer cases and 24,768 normal cases) were included. After matching patients’ age, breast density, and equipment, 1,238 and 1,238 cases were chosen as validation and test sets, respectively, and the remai...

  1. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    Science.gov (United States)

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  2. A preliminary investigation of the imaging performance of photostimulable phosphor computed radiography using a new design of mammographic quality control test object

    International Nuclear Information System (INIS)

    Cowen, A.R.; Brettle, D.S.; Coleman, N.J.; Parkin, G.J.S.

    1992-01-01

    Leeds Test Object TOR[MAM] has been designed to supplement the current FAXIL mammography test object TOR[MAX]. It contains a range of details that have a more natural radiographic appearance and has been designed as a test that more closely approximates the image quality achieved in clinical mammography. Physical aspects of the design and implementation of TOR[MAM] are presented. The TOR[MAM] has been used in a preliminary physical evaluation of the comparative image qualities produced by conventional (screen-film) and phostostimulable phosphor computed mammography and the results are discussed. TOR[MAX] results are also presented. The influence of digital image processing (enhancement) on the image quality of computed mammograms is also considered. The results presented indicate the sensitivity of TOR[MAM]. (author)

  3. Quantitative wound healing studies using a portable, low cost, handheld near-infrared optical scanner: preliminary sensitivity and specificity analysis

    Science.gov (United States)

    Lei, Jiali; Rodriguez, Suset; Jayachandran, Maanasa; Solis, Elizabeth; Gonzalez, Stephanie; Perez-Clavijo, Francesco; Wigley, Stephen; Godavarty, Anuradha

    2016-03-01

    Lower extremity ulcers are devastating complications that are still un-recognized. To date, clinicians employ visual inspection of the wound site during its standard 4-week of healing process via monitoring of surface granulation. A novel ultra-portable near-infrared optical scanner (NIROS) has been developed at the Optical Imaging Laboratory that can perform non-contact 2D area imaging of the wound site. From preliminary studies it was observed that the nonhealing wounds had a greater absorption contrast with respect to the normal site, unlike in the healing wounds. Currently, non-contact near-infrared (NIR) imaging studies were carried out on 22 lower extremity wounds at two podiatric clinics, and the sensitivity and specificity of the scanner evaluated. A quantitative optical biometric was developed that differentiates healing from non-healing wounds, based on the threshold values obtained during ROC analysis. In addition, optical images of the wound obtained from weekly imaging studies are also assessed to determine the ability of the device to predict wound healing consistently on a periodic basis. This can potentially impact early intervention in the treatment of lower extremity ulcers when an objective and quantitative wound healing approach is developed. Lastly, the incorporation of MATLAB graphical user interface (GUI) to automate the process of image acquisition, image processing and image analysis realizes the potential of NIROS to perform non-contact and real-time imaging on lower extremity wounds.

  4. Synthesis and preliminary evaluation of carbon-11-meta-hydroxyephedrine: A false transmitter agent for heart neuronal imaging

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Haka, M.S.; Van Dort, M.E.; Jewett, D.M.; Gildersleeve, D.L.; Schwaiger, M.; Wieland, D.M.

    1990-01-01

    Carbon-11-meta-hydroxyephedrine is a new radiotracer developed for mapping the sympathetic nerves of the heart. Carbon-11-meta-hydroxyephedrine is synthesized by direct N-methylation of metaraminol with [ 11 C]methyl iodide in dimethyl formamide/dimethyl sulfoxide and purified by semi-preparative reversed-phase HPLC. Total synthesis time is 45 min from end-of-bombardment. Carbon-11-meta-hydroxyephedrine is produced in 40%-50% corrected radiochemical yield with a specific activity of 900 Ci/mmol. Routine radiochemical and chemical purity are 95% and 98%, respectively. Biodistribution studies in rats show high myocardial uptake. Pretreatment with desipramine, a drug known to selectively block neuronal uptake, results in a 92% decrease in tracer accumulation in the myocardium. Metabolic studies in guinea pigs show less than 5% metabolites in heart tissue 30 min after intravenous injection suggesting that [ 11 C]meta-hydroxyephedrine is suitable for kinetic modeling. These preliminary results support this new tracer as a clinical agent for neuronal imaging of the heart

  5. Informatics in radiology: web-based preliminary reporting system for radiology residents with PACS integration.

    Science.gov (United States)

    O'Connell, Timothy; Chang, Debra

    2012-01-01

    While on call, radiology residents review imaging studies and issue preliminary reports to referring clinicians. In the absence of an integrated reporting system at the training sites of the authors' institution, residents were typing and faxing preliminary reports. To partially automate the on-call resident workflow, a Web-based system for resident reporting was developed by using the free open-source xAMP Web application framework and an open-source DICOM (Digital Imaging and Communications in Medicine) software toolkit, with the goals of reducing errors and lowering barriers to education. This reporting system integrates with the picture archiving and communication system to display a worklist of studies. Patient data are automatically entered in the preliminary report to prevent identification errors and simplify the report creation process. When the final report for a resident's on-call study is available, the reporting system queries the report broker for the final report, and then displays the preliminary report side by side with the final report, thus simplifying the review process and encouraging review of all of the resident's reports. The xAMP Web application framework should be considered for development of radiology department informatics projects owing to its zero cost, minimal hardware requirements, ease of programming, and large support community.

  6. A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography

    Energy Technology Data Exchange (ETDEWEB)

    Guildenbecher, Daniel Robert; Munz, Elise Dahnke; Farias, Paul Abraham; Thurow, Brian S [Auburn U

    2015-12-01

    Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

  7. Applying Data-driven Imaging Biomarker in Mammography for Breast Cancer Screening: Preliminary Study.

    Science.gov (United States)

    Kim, Eun-Kyung; Kim, Hyo-Eun; Han, Kyunghwa; Kang, Bong Joo; Sohn, Yu-Mee; Woo, Ok Hee; Lee, Chan Wha

    2018-02-09

    We assessed the feasibility of a data-driven imaging biomarker based on weakly supervised learning (DIB; an imaging biomarker derived from large-scale medical image data with deep learning technology) in mammography (DIB-MG). A total of 29,107 digital mammograms from five institutions (4,339 cancer cases and 24,768 normal cases) were included. After matching patients' age, breast density, and equipment, 1,238 and 1,238 cases were chosen as validation and test sets, respectively, and the remainder were used for training. The core algorithm of DIB-MG is a deep convolutional neural network; a deep learning algorithm specialized for images. Each sample (case) is an exam composed of 4-view images (RCC, RMLO, LCC, and LMLO). For each case in a training set, the cancer probability inferred from DIB-MG is compared with the per-case ground-truth label. Then the model parameters in DIB-MG are updated based on the error between the prediction and the ground-truth. At the operating point (threshold) of 0.5, sensitivity was 75.6% and 76.1% when specificity was 90.2% and 88.5%, and AUC was 0.903 and 0.906 for the validation and test sets, respectively. This research showed the potential of DIB-MG as a screening tool for breast cancer.

  8. Prospective economical evaluation of the image guided radiotherapy (I.G.R.T.) applied to prostate cancers. Preliminary results of the study 'program to support innovative and costly techniques (S.t.i.c.)-I.G.R.T

    International Nuclear Information System (INIS)

    Pommier, P.; Morelle, M.; Remonnay, R.; Crevoisier, R. de

    2009-01-01

    The preliminary results of the economical analysis of CT-guided radiotherapy use shows on one hand, a significant increase in the length of irradiation sessions related to the image guidance, but also on the other hand a substantial inter centrum variability yet to explore. (N.C.)

  9. Online detection of radiation produced in Boron-10 neutron capture reaction: preliminary studies

    International Nuclear Information System (INIS)

    Portu, A.; Galván, V.; González, S.J.; Thorp, S.; Santa Cruz, G.; Saint Martin, G.; Blostein, J.J.

    2013-01-01

    Boron microdistribution in both tumor and normal tissue sections can be studied by the autoradiography technique in solid state nuclear track detectors (SSNTD). A measurement of boron concentration in tissue is obtained through the evaluation of the density of tracks produced by alpha and lithium ions generated in the neutron capture reaction 10B(n,α) 7 Li. This knowledge is pivotal when a BNCT (Boron Neutron Capture Therapy) protocol is considered. A new methodology is proposed in order to record alpha and lithium events in real time, as light spots superimposed to the tissue section image. CCD (Charge-Coupled Device) and CMOS (Complementary Metal Oxide Semiconductor) are used as detectors, with the advantage of avoiding the superposition of events. Commercial web cams were employed for the preliminary experiments. They were partially disassembled in order to get the sensor chip uncovered. These devices were exposed to different radiation sources: 6.118 MeV alpha particles (252Cf), 0.662 MeV gamma rays ( 137 Cs) and thermal neutrons (moderated 241 Am-Be source, 103n.cm2.seg-1), to analyze the characteristics of the respective images. Pictures from tissue sections put in contact with the sensor surface were also acquired. A software was developed in Matlab to perform the image capture and processing. Early results show the feasibility of using these devices to study the distribution 10B in tissue samples. (author)

  10. Brain connectivity study of joint attention using frequency-domain optical imaging technique

    Science.gov (United States)

    Chaudhary, Ujwal; Zhu, Banghe; Godavarty, Anuradha

    2010-02-01

    Autism is a socio-communication brain development disorder. It is marked by degeneration in the ability to respond to joint attention skill task, from as early as 12 to 18 months of age. This trait is used to distinguish autistic from nonautistic populations. In this study, diffuse optical imaging is being used to study brain connectivity for the first time in response to joint attention experience in normal adults. The prefrontal region of the brain was non-invasively imaged using a frequency-domain based optical imager. The imaging studies were performed on 11 normal right-handed adults and optical measurements were acquired in response to joint-attention based video clips. While the intensity-based optical data provides information about the hemodynamic response of the underlying neural process, the time-dependent phase-based optical data has the potential to explicate the directional information on the activation of the brain. Thus brain connectivity studies are performed by computing covariance/correlations between spatial units using this frequency-domain based optical measurements. The preliminary results indicate that the extent of synchrony and directional variation in the pattern of activation varies in the left and right frontal cortex. The results have significant implication for research in neural pathways associated with autism that can be mapped using diffuse optical imaging tools in the future.

  11. Evaluation of the utility of temporal subtraction images in successive whole-body bone scans: a prospective clinical study

    International Nuclear Information System (INIS)

    Shiraishi, J.; Appelbaum, D.; Pu, Y.; Engelmann, R.; Li Qiang; Doi, K.

    2007-01-01

    We have begun a prospective clinical study for evaluating the clinical utility of temporal subtraction images in successive whole-body bone scans. The computerized temporal subtraction technique has been developed in order to highlight interval changes of abnormal lesions due to skeletal metastases, primary bone tumors, osteomyelitis, and fractures. In our initial preliminary results of the prospective study which was started on November 22, 2006 in our hospital, radiologists reported some interval changes which were not recognized in the initial standard readings, but were obvious when temporal subtraction images were viewed. The usefulness of the temporal subtraction images will be investigated in terms of its clinical utility by the prospective clinical study. (orig.)

  12. Thulium-170-labeled microparticles for local radiotherapy: preliminary studies.

    Science.gov (United States)

    Polyak, Andras; Das, Tapas; Chakraborty, Sudipta; Kiraly, Reka; Dabasi, Gabriella; Joba, Robert Peter; Jakab, Csaba; Thuroczy, Julianna; Postenyi, Zita; Haasz, Veronika; Janoki, Gergely; Janoki, Gyozo A; Pillai, Maroor R A; Balogh, Lajos

    2014-10-01

    The present article describes the preparation, characterization, and biological evaluation of Thulium-170 ((170)Tm) [T1/2 = 128.4 days; Eβmax = 968 keV; Eγ = 84 keV (3.26%)] labeled tin oxide microparticles for its possible use in radiation synovectomy (RSV) of medium-sized joints. (170)Tm was produced by irradiation of natural thulium oxide target. 170Tm-labeled microparticles were synthesized with high yield and radionuclidic purity (> 99%) along with excellent in vitro stability by following a simple process. Particle sizes and morphology of the radiolabeled particles were examined by light microscope, dynamic light scattering, and transmission electron microscope and found to be of stable spherical morphology within the range of 1.4-3.2 μm. The preparation was injected into the knee joints of healthy Beagle dogs intraarticularly for biological studies. Serial whole-body and regional images were taken by single-photon-emission computed tomography (SPECT) and SPECT-CT cameras up to 9 months postadministration, which showed very low leakage (compound did not show any possible radiotoxicological effect. These preliminary studies showed that 170Tm-labeled microparticles could be a promising nontoxic and effective radiopharmaceutical for RSV applications or later local antitumor therapy.

  13. Nasolabial Growth in Individuals With Unilateral Cleft Lip and Palate: A Preliminary Study of Longitudinal Observation Using Three-Dimensional Stereophotogrammetry.

    Science.gov (United States)

    Alazzawi, Omar; Morioka, Daichi; Miyabe, Mai; Tosa, Yasusoshi; Ohkubo, Fumio; Yoshimoto, Shinya

    2017-07-01

    There are limited numbers of studies comparing the preoperative and postoperative facial features of infants with unilateral cleft lip and palate (UCLP) using three-dimensional (3D) stereophotogrammetry. The authors attempted an anthropometric analysis of nasolabial asymmetry 1 year after primary lip repair using a handheld 3D imaging system. Five different nasolabial dimensions in 24 infants with UCLP were measured using 3D images captured during primary lip repair and again, 1 year after the repair. The nasal and upper-lip elements of the cleft side were significantly changed after primary lip repair, and nasolabial asymmetry was anthropometrically improved. This is a preliminary longitudinal observation of nasolabial growth in individuals with UCLP using 3D stereophotogrammetric technique. The authors would like to follow these children until adulthood, capturing 3D images at every intervention.

  14. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  15. Preliminary closed Brayton cycle study for a space reactor application

    International Nuclear Information System (INIS)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de; Camillo, Giannino Ponchio

    2007-01-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  16. Preliminary closed Brayton cycle study for a space reactor application

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de [Institute for Advanced Studies, Sao Jose dos Campos, SP (Brazil)]. E-mail: guimarae@ieav.cta.br; Camillo, Giannino Ponchio [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil)]. E-mail: gianninocamillo@gmail.com

    2007-07-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  17. Three-Dimensional Imaging Using Microcomputed Tomography For Studying Gaharu Morphology

    International Nuclear Information System (INIS)

    Yazid, Khair'iah; Bin Awang, Mat Rasol; Mohamed, Abdul Aziz; Bin Hj Khalid, Mohd Ashhar; Masschaele, Bert; Abdullah, Mohd. Zaid; Saleh, Junita Mohamad

    2010-01-01

    To demonstrates the potential application of the high resolution X-ray micro-CT technique in the analysis of internal structure in Gaharu wood. Gaharu or internationally, Agar wood, is known for its fragrant resinous wood. The hardware device used in this study was an X-ray micro-CT scanner at Center of Tomography (UGCT), CT facility in Ghent University, Belgium. This technique allows the 3D investigation of the internal structure of the wood in a non-destructive way. Most of the data analysis was done with the software VG Studio Max and MATLAB. Here we present some preliminary results from three-dimensional images from a piece of high grade Gaharu. Micro-CT images of the specimens were obtained at 7 μm resolution. Besides a clear distinction between pores and material, some bright white areas occur in the reconstruction images. Not only the volume visualization is helpful, morphological parameters of open-pores and dark resins are calculated from these 3D data set. The micro-CT technique is a valid support for evaluating the pores structure and resin distribution in Gaharu.

  18. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    LENUS (Irish Health Repository)

    Mc Laughlin, Patrick

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  19. Preliminary design study of a steady state tokamak device

    International Nuclear Information System (INIS)

    Miya, Naoyuki; Nakajima, Shinji; Ushigusa, Kenkichi; and athors)

    1992-09-01

    Preliminary design study has been made for a steady tokamak with the plasma current of 10MA, as the next to the JT-60U experimental programs. The goal of the research program is the integrated study of steady state, high-power physics and technology. Present candidate design is to use superconducting TF and PF magnet systems and long pulse operation of 100's-1000's of sec with non inductive current drive mainly by 500keV negative ion beam injection of 60MW. Low activation material such as titanium alloy is chosen for the water tank type vacuum vessel, which is also the nuclear shield for the superconducting coils. The present preliminary design study shows that the device can meet the existing JT-60U facility capability. (author)

  20. Image processing on the image with pixel noise bits removed

    Science.gov (United States)

    Chuang, Keh-Shih; Wu, Christine

    1992-06-01

    Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.

  1. Preliminary study on effects of 60Co γ-irradiation on video quality and the image de-noising methods

    International Nuclear Information System (INIS)

    Yuan Mei; Zhao Jianbin; Cui Lei

    2011-01-01

    There will be variable noises appear on images in video once the play device irradiated by γ-rays, so as to affect the image clarity. In order to eliminate the image noising, the affection mechanism of γ-irradiation on video-play device was studied in this paper and the methods to improve the image quality with both hardware and software were proposed by use of protection program and de-noising algorithm. The experimental results show that the scheme of video de-noising based on hardware and software can improve effectively the PSNR by 87.5 dB. (authors)

  2. Cone-beam volume CT breast imaging: Feasibility study

    International Nuclear Information System (INIS)

    Chen Biao; Ning Ruola

    2002-01-01

    X-ray projection mammography, using a film/screen combination, or digital techniques, has proven to be the most effective imaging modality currently available for early detection of breast cancer. However, the inherent superimposition of structures makes a small carcinoma (a few millimeters in size) difficult to detect when it is occult or in dense breasts, leading to a high false-positive biopsy rate. Cone-beam x-ray-projection-based volume imaging using flat panel detectors (FPDs) may allow obtaining three-dimensional breast images, resulting in more accurate diagnosis of structures and patterns of lesions while eliminating the hard compression of breasts. This article presents a novel cone-beam volume computed tomographic breast imaging (CBVCTBI) technique based on the above techniques. Through a variety of computer simulations, the key issues of the system and imaging techniques were addressed, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissue and lesions, x-ray setting techniques, the absorbed dose estimation, and the quantitative effect of x-ray scattering on image quality. The preliminary simulation results support the proposed CVBCTBI modality for breast imaging in respect to its feasibility and practicability. The absorbed dose level is comparable to that of current mammography and will not be a prominent problem for this imaging technique. Compared to conventional mammography, the proposed imaging technique with isotropic spatial resolution will potentially provide significantly better low-contrast detectability of breast tumors and more accurate location of breast lesions

  3. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  4. Preliminary study on hypoxic-ischemic encephalopathy in neonates with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Wang Xiaoming; Chen Liying; Lin Nan; Guo Qiyong

    2005-01-01

    Objective: To evaluate hypoxic-ischemic encephalopathy (HIE) in neonates with diffusion-weighted MR imaging, and to explore the value and limitation of diffusion-weighted imaging (DWI) compared with conventional magnetic resonance imaging. Methods: Conventional magnetic resonance T 1 -weighted imaging (T 1 WI) and DWI (b=700 s/mm 2 ) were performed in 36 neonates with HIE (average age, 8.44 days; range, 3 hours to 22 days), and the cortex and subcortical white matter, deep white matter, basal ganglia and thalamus, cerebral ventricle, and extra-cerebral interspace etc were observed. Results: Signal abnormalities were shown on DWI with hypoxic-ischemic insults, which included diffuse brain damage (19.4%, 7/36): extensive high signals in the regional cortex, subcortical and deep white matter; localized brain damage: high signals along lateral ventricular wall and triangular part (27.8%, 10/36 ), and punctate high signals in the frontal deep white matter (5.6%, 2/36). On T 1 WI, the incidence of the corresponding changes were 16.7% (6/36), 36.1% (13/36), and 30.6%(11/36), respectively. Hemorrhagic lesions demonstrated high signals on T 1 WI and no signals on DWI. Conclusion: DWI was applicable for acute HIE, and T 1 WI was suitable for subacute and chronic HIE. (authors)

  5. TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

    Energy Technology Data Exchange (ETDEWEB)

    Li, H; Dolly, S; Zhao, T; Anastasio, M; Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Ritter, A; Colombo, V; Raupach, R; Huenemohr, N [Siemens Healthcare GmbH, Deutschland (Germany); Mistry, N [Siemens Medical Solutions USA, Malvern, PA (United States); Yu, L [Mayo Clinic, Rochester, MN (United States)

    2016-06-15

    Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

  6. Experimental MR imaging with Gd-DOTA: Preliminary results

    International Nuclear Information System (INIS)

    Schouman-Claeys, E.; Kien, P.; Caille, J.M.; Bonnemain, B.; Frija, G.

    1986-01-01

    To evaluate the paramagnetic properties of a new gadolinium chelate, Gd-DOTA, in vitro and in vivo MR imaging was performed with a 0.5-T supraconductive magnet. The in vitro study consisted in measuring the MR signal obtained with various concentrations of Gd-DOTA and Gd-DTPA in different solutions. Potentialization of the paramagnetic properties of both DOTA and DTPA can be achieved by deuterium, glycerol, and protein solutions. The in vivo study was performed in rabbits with various experimental lesions. Enhancement of anatomic details was obtained with both Gd-DOTA and Gd-DTPA. There was no significant difference between Gd-DOTA and Gd-DTPA, both for in vitro and in vivo experiments. Gd-DOTA appears to be a potential paramagnetic agent for MR imaging

  7. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kyung Cha, Bo [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae, E-mail: sarim@keri.re.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Huh, Young [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  8. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    International Nuclear Information System (INIS)

    Kyung Cha, Bo; Seo, Chang-Woo; Yang, Keedong; Jeon, Seongchae; Huh, Young

    2015-01-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally

  9. Gemini Planet Imager: Preliminary Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Macintosh, B

    2007-05-10

    For the first time in history, direct and indirect detection techniques have enabled the exploration of the environments of nearby stars on scales comparable to the size of our solar system. Precision Doppler measurements have led to the discovery of the first extrasolar planets, while high-contrast imaging has revealed new classes of objects including dusty circumstellar debris disks and brown dwarfs. The ability to recover spectrophotometry for a handful of transiting exoplanets through secondary-eclipse measurements has allowed us to begin to study exoplanets as individual entities rather than points on a mass/semi-major-axis diagram and led to new models of planetary atmospheres and interiors, even though such measurements are only available at low SNR and for a handful of planets that are automatically those most modified by their parent star. These discoveries have galvanized public interest in science and technology and have led to profound new insights into the formation and evolution of planetary systems, and they have set the stage for the next steps--direct detection and characterization of extrasolar Jovian planets with instruments such as the Gemini Planet Imager (GPI). As discussed in Volume 1, the ability to directly detect Jovian planets opens up new regions of extrasolar planet phase space that in turn will inform our understanding of the processes through which these systems form, while near-IR spectra will advance our understanding of planetary physics. Studies of circumstellar debris disks using GPI's polarimetric mode will trace the presence of otherwise-invisible low-mass planets and measure the build-up and destruction of planetesimals. To accomplish the science mission of GPI will require a dedicated instrument capable of achieving contrast of 10{sup -7} or more. This is vastly better than that delivered by existing astronomical AO systems. Currently achievable contrast, about 10{sup -5} at separations of 1 arc second or larger, is

  10. Laser-wakefield accelerators for medical phase contrast imaging: Monte Carlo simulations and experimental studies

    Science.gov (United States)

    Cipiccia, S.; Reboredo, D.; Vittoria, Fabio A.; Welsh, G. H.; Grant, P.; Grant, D. W.; Brunetti, E.; Wiggins, S. M.; Olivo, A.; Jaroszynski, D. A.

    2015-05-01

    X-ray phase contrast imaging (X-PCi) is a very promising method of dramatically enhancing the contrast of X-ray images of microscopic weakly absorbing objects and soft tissue, which may lead to significant advancement in medical imaging with high-resolution and low-dose. The interest in X-PCi is giving rise to a demand for effective simulation methods. Monte Carlo codes have been proved a valuable tool for studying X-PCi including coherent effects. The laser-plasma wakefield accelerators (LWFA) is a very compact particle accelerator that uses plasma as an accelerating medium. Accelerating gradient in excess of 1 GV/cm can be obtained, which makes them over a thousand times more compact than conventional accelerators. LWFA are also sources of brilliant betatron radiation, which are promising for applications including medical imaging. We present a study that explores the potential of LWFA-based betatron sources for medical X-PCi and investigate its resolution limit using numerical simulations based on the FLUKA Monte Carlo code, and present preliminary experimental results.

  11. Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Liu, Jing-Hong; Sun, Mei-Yu; Wang, He-Qing; Liu, Yi-Jun

    2015-03-05

    The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT) virtual noncontrast (VNC) spectral imaging in a retrospective analysis. Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC) and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa), venous (VNCv), and equilibrium (VNCe) phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR) of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05). The quality of VNCe images was significantly worse than that of other three groups (P 0.05). The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05). The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  12. Application of Computed Tomography Virtual Noncontrast Spectral Imaging in Evaluation of Hepatic Metastases: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Shi-Feng Tian

    2015-01-01

    Full Text Available Objective: The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT virtual noncontrast (VNC spectral imaging in a retrospective analysis. Methods: Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa, venous (VNCv, and equilibrium (VNCe phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. Results: There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05. The quality of VNCe images was significantly worse than that of other three groups (P 0.05. The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05. Conclusions: The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  13. Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    International Nuclear Information System (INIS)

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A.

    1990-01-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed

  14. Optical fiber sensors for image formation in radiodiagnostic - preliminary essays; Sensores a fibra optica para formacao de imagens em radiodiagnostico - ensaios preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Cesar C. de; Werneck, Marcelo M. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Biomedica

    1998-07-01

    This work describes preliminary experiments that will bring subsidies to analyze the capability to implement a system able to capture radiological images with new sensor system, comprised by FOs scanning process and I-CCD camera. These experiments have the main objective to analyze the optical response from FOs bundle, with several typos of scintillators associated with them, when it is submitted to medical x-rays exposition. (author)

  15. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    International Nuclear Information System (INIS)

    Tintera, Jaroslav; Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter

    2004-01-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  16. New partially parallel acquisition technique in cerebral imaging: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Tintera, Jaroslav [Institute for Clinical and Experimental Medicine, Prague (Czech Republic); Gawehn, Joachim; Bauermann, Thomas; Vucurevic, Goran; Stoeter, Peter [University Clinic Mainz, Institute of Neuroradiology, Mainz (Germany)

    2004-12-01

    In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used. (orig.)

  17. Simulation of an image network in a medical image information system

    International Nuclear Information System (INIS)

    Massar, A.D.A.; De Valk, J.P.J.; Reijns, G.L.; Bakker, A.R.

    1985-01-01

    The desirability of an integrated (digital) communication system for medical images is widely accepted. In the USA and in Europe several experimental projects are in progress to realize (a part of) such a system. Among these is the IMAGIS project in the Netherlands. From the conclusions of the preliminary studies performed, some requirements can be formulated such a system should meet in order to be accepted by its users. For example, the storage resolution of the images should match the maximum resolution of the presently acquired digital images. This determines the amount of data and therefore the storage requirements. Further, the desired images should be there when needed. This time constraint determines the speed requirements to be imposed on the system. As compared to current standards, very large storage capacities and very fast communication media are needed to meet these requirements. By employing cacheing techniques and suitable data compression schemes for the storage and by carefully choosing the network protocols, bare capacity demands can be alleviated. A communication network is needed to make the imaging system available over a larger area. As the network is very likely to become a major bottleneck for system performance, effects of variation of various attributes have to be carefully studied and analysed. After interesting results had been obtained (although preliminary) using a simulation model for a layered storage structure, it was decided to apply simulation also to this problem. Effects of network topology, access protocols and buffering strategies will be tested. Changes in performance resulting from changes in various network parameters will be studied. Results of this study at its present state are presented

  18. Assessment of trabecular bone changes around endosseous implants using image analysis techniques: A preliminary study

    International Nuclear Information System (INIS)

    Zuki, Mervet El; Omami, Galal; Horner, Keith

    2014-01-01

    The objective of this study was to assess the trabecular bone changes that occurred around functional endosseous dental implants by means of radiographic image analysis techniques. Immediate preoperative and postoperative periapical radiographs of de-identified implant patients at the University Dental Hospital of Manchester were retrieved, screened for specific inclusion criteria, digitized, and quantified for structural elements of the trabecular bone around the endosseous implants, by using image analysis techniques. Data were analyzed using SPSS version 11.5. P values of less than 0.05 were considered statistically significant. A total of 12 implants from 11 patients were selected for the study, and 26 regions of interest were obtained. There was a significant increase in the bone area in terms of the mean distance between nodes (p=0.006) and a significant decrease in the marrow area in terms of the bone area (p=0.006) and the length of marrow spaces (p=0.032). It appeared that the bone around the implant underwent remodeling that resulted in a net increase in bone after implant placement.

  19. Assessment of trabecular bone changes around endosseous implants using image analysis techniques: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Zuki, Mervet El [Dept. of Oral Medicine and Radiology, Benghazi University College of Dentistry, Benghazi (Libya); Omami, Galal [Oral Diagnosis and Polyclinics, Faculty of Dentistry, The University of Hong Kong (Hong Kong); Horner, Keith [Dept. of Oral Radiology, University Dental Hospital of Manchester, Manchester (United Kingdom)

    2014-06-15

    The objective of this study was to assess the trabecular bone changes that occurred around functional endosseous dental implants by means of radiographic image analysis techniques. Immediate preoperative and postoperative periapical radiographs of de-identified implant patients at the University Dental Hospital of Manchester were retrieved, screened for specific inclusion criteria, digitized, and quantified for structural elements of the trabecular bone around the endosseous implants, by using image analysis techniques. Data were analyzed using SPSS version 11.5. P values of less than 0.05 were considered statistically significant. A total of 12 implants from 11 patients were selected for the study, and 26 regions of interest were obtained. There was a significant increase in the bone area in terms of the mean distance between nodes (p=0.006) and a significant decrease in the marrow area in terms of the bone area (p=0.006) and the length of marrow spaces (p=0.032). It appeared that the bone around the implant underwent remodeling that resulted in a net increase in bone after implant placement.

  20. Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Takashi; Hori, Masatoshi; Onishi, Hiromitsu; Sakane, Makoto; Tsuboyama, Takahiro; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Nakamoto, Atsushi; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Osaka (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynaecology, Osaka (Japan)

    2017-12-15

    To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. (orig.)

  1. Pharmacognostic standardization and preliminary phytochemical studies of Gaultheria trichophylla.

    Science.gov (United States)

    Alam, Fiaz; Najum us Saqib, Qazi

    2015-01-01

    Gaultheria trichophylla Royle (Ericaceae) has long been used for various ailments in traditional systems of medicines; most importantly it is used against pain and inflammation. This study determines various pharmacognostic and phytochemical standards helpful to ensure the purity, safety, and efficacy of medicinal plant G. trichophylla. Intact aerial parts, powdered materials, and extracts were examined macro- and microscopically and pharmacognostic standardization parameters were determined in accordance with the guidelines given by the World Health Organization (WHO). Parameters including extractive values, ash values, and loss on drying were determined. Preliminary phytochemical tests, fluorescence analysis, and chromatographic profiling were performed for the identification and standardization of G. trichophylla. The shape, size, color, odor, and surface characteristics were noted for intact drug and powdered drug material of G. trichophylla. Light and scanning electron microscope images of cross section of leaf and powdered microscopy revealed useful diagnostic features. Histochemical, phytochemical, physicochemical, and fluorescence analysis proved useful tools to differentiate the powdered drug material. High-performance liquid chromatography (HPLC) analysis showed the presence of important phytoconstituents such as gallic acid, rutin, and quercetin. The data generated from the present study help to authenticate the medicinally important plant G. trichophylla. Qualitative and quantitative microscopic features may be helpful for establishing the pharmacopeia standards. Morphology as well as various pharmacognostic aspects of different parts of the plant were studied and described along with phytochemical and physicochemical parameters, which could be helpful in further isolation and purification of medicinally important compounds.

  2. Study on Foreigners' Perception on Romania's Image as Tourism Destination

    Directory of Open Access Journals (Sweden)

    Ruxandra Irina POPESCU

    2013-06-01

    Full Text Available Romania’s image worldwide is a major priority for our public authorities. The aim of this study is to identify foreigners’ perception on Romania’s image as tourism destination departing from three research hypothesis: foreigners’ perception on Romania’s image as a result of Romanians behavior inside and outside the country’s borders, foreign visitors’ perception on tourism services and level of knowledge of Romania’s tourism brand across the borders. The research gathered the opinions of 1.150 foreigners from 10 countries using a questionnaire that integrated variables corresponding to the research questions. The survey was carried out in 11 representative places for foreign tourists’ visits, as well as on the internet, using the Wayn.com website, which allowed the selection of foreign citizens that have visited Romania at least once. The research is relevant not only from the perspective of its direct results regarding foreigners’ perception on Romania’s tourism brand, but might as well be seen as an instrument for analyzing the preliminary results of the campaign ‘Romania, explore the Carpathian garden’, that started in 2010 and is still in progress.

  3. Characterization of Fine Metal Particles Derived from Shredded WEEE Using a Hyperspectral Image System: Preliminary Results

    Science.gov (United States)

    Candiani, Gabriele; Picone, Nicoletta; Pompilio, Loredana; Pepe, Monica; Colledani, Marcello

    2017-01-01

    Waste of electric and electronic equipment (WEEE) is the fastest-growing waste stream in Europe. The large amount of electric and electronic products introduced every year in the market makes WEEE disposal a relevant problem. On the other hand, the high abundance of key metals included in WEEE has increased the industrial interest in WEEE recycling. However, the high variability of materials used to produce electric and electronic equipment makes key metals’ recovery a complex task: the separation process requires flexible systems, which are not currently implemented in recycling plants. In this context, hyperspectral sensors and imaging systems represent a suitable technology to improve WEEE recycling rates and the quality of the output products. This work introduces the preliminary tests using a hyperspectral system, integrated in an automatic WEEE recycling pilot plant, for the characterization of mixtures of fine particles derived from WEEE shredding. Several combinations of classification algorithms and techniques for signal enhancement of reflectance spectra were implemented and compared. The methodology introduced in this study has shown characterization accuracies greater than 95%. PMID:28505070

  4. System description and analysis. Part 1: Feasibility study for helicopter/VTOL wide-angle simulation image generation display system

    Science.gov (United States)

    1977-01-01

    A preliminary design for a helicopter/VSTOL wide angle simulator image generation display system is studied. The visual system is to become part of a simulator capability to support Army aviation systems research and development within the near term. As required for the Army to simulate a wide range of aircraft characteristics, versatility and ease of changing cockpit configurations were primary considerations of the study. Due to the Army's interest in low altitude flight and descents into and landing in constrained areas, particular emphasis is given to wide field of view, resolution, brightness, contrast, and color. The visual display study includes a preliminary design, demonstrated feasibility of advanced concepts, and a plan for subsequent detail design and development. Analysis and tradeoff considerations for various visual system elements are outlined and discussed.

  5. Dual-energy imaging in full-field digital mammography: a phantom study

    International Nuclear Information System (INIS)

    Taibi, A; Fabbri, S; Baldelli, P; Maggio, C di; Gennaro, G; Marziani, M; Tuffanelli, A; Gambaccini, M

    2003-01-01

    A dual-energy technique which employs the basis decomposition method is being investigated for application to digital mammography. A three-component phantom, made up of plexiglas, polyethylene and water, was doubly exposed with the full-field digital mammography system manufactured by General Electric. The 'low' and 'high' energy images were recorded with a Mo/Mo anode-filter combination and a Rh/Rh combination, respectively. The total dose was kept within the acceptable levels of conventional mammography. The first hybrid images obtained with the dual-energy algorithm are presented in comparison with a conventional radiograph of the phantom. Image-quality characteristics at contrast cancellation angles between plexiglas and water are discussed. Preliminary results show that a combination of a standard Mo-anode 28 kV radiograph with a Rh-anode 49 kV radiograph provides the best compromise between image-quality and dose in the hybrid image

  6. Preliminary 19F-MRS Study of Tumor Cell Proliferation with 3′-deoxy-3′-fluorothymidine and Its Metabolite (FLT-MP

    Directory of Open Access Journals (Sweden)

    In Ok Ko

    2017-01-01

    Full Text Available The thymidine analogue 3′-deoxy-3′-[18F]fluorothymidine, or [18F]fluorothymidine ([18F]FLT, is used to measure tumor cell proliferation with positron emission tomography (PET imaging technology in nuclear medicine. FLT is phosphorylated by thymidine kinase 1 (TK1 and then trapped inside cells; it is not incorporated into DNA. Imaging with 18F-radiolabeled FLT is a noninvasive technique to visualize cellular proliferation in tumors. However, it is difficult to distinguish between [18F]FLT and its metabolites by PET imaging, and quantification has not been attempted using current imaging methods. In this study, we successfully acquired in vivo F19 spectra of natural or nonradioactive 3′-deoxy-3′-fluorothymidine ([19F]FLT and its monophosphate metabolite (FLT-MP in a tumor xenograft mouse model using 9.4T magnetic resonance imaging (MRI. This preliminary result demonstrates that 19F magnetic resonance spectroscopy (MRS with FLT is suitable for the in vivo assessment of tumor aggressiveness and for early prediction of treatment response.

  7. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  8. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  9. Preliminary summary of the ETF conceptual studies

    Science.gov (United States)

    Seikel, G. R.; Bercaw, R. W.; Pearson, C. V.; Owens, W. R.

    1978-01-01

    Power plant studies have shown the attractiveness of MHD topped steam power plants for baseload utility applications. To realize these advantages, a three-phase development program was initiated. In the first phase, the engineering data and experience were developed for the design and construction of a pilot plant, the Engineering Test Facility (ETF). Results of the ETF studies are reviewed. These three parallel independent studies were conducted by industrial teams led by the AVCO Everett Research Laboratory, the General Electric Corporation, and the Westinghouse Corporation. A preliminary analysis and the status of the critical evaluation of these results are presented.

  10. A preliminary neutron crystallographic study of thaumatin

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Susana C. M. [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); Blakeley, Matthew P. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); Leal, Ricardo M. F. [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); ESRF, 6 Rue Jules Horowitz, BP-220, 38043 Grenoble (France); Mitchell, Edward P. [EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); ESRF, 6 Rue Jules Horowitz, BP-220, 38043 Grenoble (France); Forsyth, V. Trevor, E-mail: tforsyth@ill.fr [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom)

    2008-05-01

    Preliminary neutron crystallographic data from the sweet protein thaumatin have been recorded using the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results illustrate the feasibility of a full neutron structural analysis aimed at further understanding the molecular basis of the perception of sweet taste. Such an analysis will exploit the use of perdeuterated thaumatin. A preliminary neutron crystallographic study of the sweet protein thaumatin is presented. Large hydrogenated crystals were prepared in deuterated crystallization buffer using the gel-acupuncture method. Data were collected to a resolution of 2 Å on the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results demonstrate the feasibility of a full neutron crystallographic analysis of this structure aimed at providing relevant information on the location of H atoms, the distribution of charge on the protein surface and localized water in the structure. This information will be of interest for understanding the specificity of thaumatin–receptor interactions and will contribute to further understanding of the molecular mechanisms underlying the perception of taste.

  11. Diffusion tensor imaging applications in multiple sclerosis patients using 3T magnetic resonance: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Testaverde, Lorenzo; Caporali, Laura [University ' ' Sapienza' ' of Rome, Department of Radiological Sciences, Rome (Italy); Venditti, Eugenio; Grillea, Giovanni [U.O.C. Neuroradiologia, I.R.C.C.S. ' ' Neuromed' ' , Pozzilli (Italy); Colonnese, Claudio [University ' ' Sapienza' ' of Rome, Department of Radiological Sciences, Rome (Italy); U.O.C. Neuroradiologia, I.R.C.C.S. ' ' Neuromed' ' , Pozzilli (Italy)

    2012-05-15

    This study evaluated patients with multiple sclerosis using diffusion tensor imaging (DTI) to obtain fractional anisotropy (FA) and mean diffusivity (MD) values. We investigated the possible statistically significant variation of MD and FA in different MS patients, compared simultaneously, putting in comparison their normal appearing white matter (NAWM) and white matter affected by disease (plaques), both during activity and in remission, with normal white matter (NWM) of control subjects. Statistical analysis using Levene's test for comparison of variances revealed significant (P < 0.05) differences between FA values of the NWM of the controls and those of NAWM and active or inactive lesions, of the patients in the study. However, the differences between MD values of the NWM of the controls and those of NAWM and active or inactive lesions of the patients in the study were judged not significant (P > 0.05). Imaging of MS using MRI techniques is constantly searching for reproducible quantitative parameter. This study shows how these parameters can be identified in the MD and FA values, and thus suggests the implementation of MRI routine protocols for diagnosing MS with the DTI analysis, since it can provide valuable information otherwise unobtainable. (orig.)

  12. Amide Proton Transfer Magnetic Resonance Imaging of Alzheimer′s Disease at 3.0 Tesla: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2015-01-01

    Full Text Available Background: Amide proton transfer (APT imaging has recently emerged as an important contrast mechanism for magnetic resonance imaging (MRI in the field of molecular and cellular imaging. The aim of this study was to evaluate the feasibility of APT imaging to detect cerebral abnormality in patients with Alzheimer′s disease (AD at 3.0 Tesla. Methods: Twenty AD patients (9 men and 11 women; age range, 67-83 years and 20 age-matched normal controls (11 men and 9 women; age range, 63-82 years underwent APT and traditional MRI examination on a 3.0 Tesla MRI system. The magnetic resonance ratio asymmetry (MTR asym values at 3.5 ppm of bilateral hippocampi (Hc, temporal white matter regions, occipital white matter regions, and cerebral peduncles were measured on oblique axial APT images. MTR asym (3.5 ppm values of the cerebral structures between AD patients and control subjects were compared with independent samples t-test. Controlling for age, partial correlation analysis was used to investigate the associations between mini-mental state examination (MMSE and the various MRI measures among AD patients. Results: Compared with normal controls, MTR asym (3.5 ppm values of bilateral Hc were significantly increased in AD patients (right 1.24% ± 0.21% vs. 0.83% ± 0.19%, left 1.18% ± 0.18% vs. 0.80%± 0.17%, t = 3.039, 3.328, P = 0.004, 0.002, respectively. MTR asym (3.5 ppm values of bilateral Hc were significantly negatively correlated with MMSE (right r = −0.559, P = 0.013; left r = −0.461, P = 0.047. Conclusions: Increased MTR asym (3.5 ppm values of bilateral Hc in AD patients and its strong correlations with MMSE suggest that APT imaging could potentially provide imaging biomarkers for the noninvasive molecular diagnosis of AD.

  13. Krypton for computed tomography lung ventilation imaging: preliminary animal data.

    Science.gov (United States)

    Mahnken, Andreas H; Jost, Gregor; Pietsch, Hubertus

    2015-05-01

    The objective of this study was to assess the feasibility and safety of krypton ventilation imaging with intraindividual comparison to xenon ventilation computed tomography (CT). In a first step, attenuation of different concentrations of xenon and krypton was analyzed in a phantom setting. Thereafter, 7 male New Zealand white rabbits (4.4-6.0 kg) were included in an animal study. After orotracheal intubation, an unenhanced CT scan was obtained in end-inspiratory breath-hold. Thereafter, xenon- (30%) and krypton-enhanced (70%) ventilation CT was performed in random order. After a 2-minute wash-in of gas A, CT imaging was performed. After a 45-minute wash-out period and another 2-minute wash-in of gas B, another CT scan was performed using the same scan protocol. Heart rate and oxygen saturation were measured. Unenhanced and krypton or xenon data were registered and subtracted using a nonrigid image registration tool. Enhancement was quantified and statistically analyzed. One animal had to be excluded from data analysis owing to problems during intubation. The CT scans in the remaining 6 animals were completed without complications. There were no relevant differences in oxygen saturation or heart rate between the scans. Xenon resulted in a mean increase of enhancement of 35.3 ± 5.5 HU, whereas krypton achieved a mean increase of 21.9 ± 1.8 HU in enhancement (P = 0.0055). The use of krypton for lung ventilation imaging appears to be feasible and safe. Despite the use of a markedly higher concentration of krypton, enhancement is significantly worse when compared with xenon CT ventilation imaging, but sufficiently high for CT ventilation imaging studies.

  14. MALLARD REPRODUCTIVE TESTING IN A POND ENVIRONMENT: A PRELIMINARY STUDY

    Science.gov (United States)

    A 2-year preliminary study was conducted on mallard ducks to determine the feasibility of using outdoor pond enclosures for reproductive studies and to evaluate the effects of the insecticide chlorpyrifos on mallard reproduction. No significant reproductive effects were observed ...

  15. RHSEG and Subdue: Background and Preliminary Approach for Combining these Technologies for Enhanced Image Data Analysis, Mining and Knowledge Discovery

    Science.gov (United States)

    Tilton, James C.; Cook, Diane J.

    2008-01-01

    Under a project recently selected for funding by NASA's Science Mission Directorate under the Applied Information Systems Research (AISR) program, Tilton and Cook will design and implement the integration of the Subdue graph based knowledge discovery system, developed at the University of Texas Arlington and Washington State University, with image segmentation hierarchies produced by the RHSEG software, developed at NASA GSFC, and perform pilot demonstration studies of data analysis, mining and knowledge discovery on NASA data. Subdue represents a method for discovering substructures in structural databases. Subdue is devised for general-purpose automated discovery, concept learning, and hierarchical clustering, with or without domain knowledge. Subdue was developed by Cook and her colleague, Lawrence B. Holder. For Subdue to be effective in finding patterns in imagery data, the data must be abstracted up from the pixel domain. An appropriate abstraction of imagery data is a segmentation hierarchy: a set of several segmentations of the same image at different levels of detail in which the segmentations at coarser levels of detail can be produced from simple merges of regions at finer levels of detail. The RHSEG program, a recursive approximation to a Hierarchical Segmentation approach (HSEG), can produce segmentation hierarchies quickly and effectively for a wide variety of images. RHSEG and HSEG were developed at NASA GSFC by Tilton. In this presentation we provide background on the RHSEG and Subdue technologies and present a preliminary analysis on how RHSEG and Subdue may be combined to enhance image data analysis, mining and knowledge discovery.

  16. Preliminary study on the time-related changes of the infrared thermal images of the human body

    Science.gov (United States)

    Li, Ziru; Zhang, Xusheng; Lin, Gang; Chen, Zhigang

    2009-08-01

    It is of great importance to study the manifestations and the influencing factors of the time-related changes of infrared thermal images (ITI) of human body since the variable body surface temperature distribution seriously affected the application of ITI in medicine. In this paper, manifestations of time-related changes of the ITI of human body from three double-blind randomized trials and their correlation with meteorological factors (e.g. temperature, pressure, humidity, cold front passage and tropical cyclone landing) were studied. The trials were placebo or drug controlled studying the influences of Chinese medicine health food (including Shengsheng capsule with immunity adjustment function, Shengan capsule with sleep improvement function and Shengyi capsule with the function of helping to decrease serum lipid) on the ITI of human body. In the first thirty-six days of the trials images were scanned every six days and image data in the seven observation time spots (including the 0, 6, 12, 18, 24, 30, 36 day of the trial) were used for the time-related study. For every subject the scanned time was fixed in the day within two hours. The ITI features which could reflect the functions of the health foods were studied. The indexes of the features were relative magnitude (temperature difference between the viewing area and the reference area). Results showed that the variation tendencies of the trial group and control group were basically the same in placebo controlled trials and some of the long-term effects of Chinese medicine health food could be reflected significantly in certain time spots in the first thirty-six days. Time-related changes of the ITI of human body were closely related with meteorological factors but there were other influencing factors still need to be studied. As the ITI of human body could reflect the influences of Chinese medicine health foods and are closely related with meteorology, there are bright prospects for the application of ITI in

  17. A New Silver Complex with Ofloxacin – Preliminary Study

    Directory of Open Access Journals (Sweden)

    Rusu Aura

    2016-06-01

    Full Text Available Objective: Silver complexes of antibacterial quinolones have the potential advantage of combining the antibacterial activity of silver and fluoroquinolones. The objective of our study was the preparation and the preliminary physico-chemical characterization of a silver complex with ofloxacin.

  18. Pathological diagnosis of bladder cancer by image analysis of hypericin induced fluorescence cystoscopic images

    Science.gov (United States)

    Kah, James C. Y.; Olivo, Malini C.; Lau, Weber K. O.; Sheppard, Colin J. R.

    2005-08-01

    Photodynamic diagnosis of bladder carcinoma based on hypericin fluorescence cystoscopy has shown to have a higher degree of sensitivity for the detection of flat bladder carcinoma compared to white light cystoscopy. The potential of the photosensitizer hypericin-induced fluorescence in performing non-invasive optical biopsy to grade bladder cancer in vivo using fluorescence cystoscopic image analysis without surgical resection for tissue biopsy is investigated in this study. The correlation between tissue fluorescence and histopathology of diseased tissue was explored and a diagnostic algorithm based on fluorescence image analysis was developed to classify the bladder cancer without surgical resection for tissue biopsy. Preliminary results suggest a correlation between tissue fluorescence and bladder cancer grade. By combining both the red-to-blue and red-to-green intensity ratios into a 2D scatter plot yields an average sensitivity and specificity of around 70% and 85% respectively for pathological cancer grading of the three different grades of bladder cancer. Therefore, the diagnostic algorithm based on colorimetric intensity ratio analysis of hypericin fluorescence cystoscopic images developed in this preliminary study shows promising potential to optically diagnose and grade bladder cancer in vivo.

  19. PET/MRI: a novel hybrid imaging technique. Major clinical indications and preliminary experience in Brazil.

    Science.gov (United States)

    Vitor, Taise; Martins, Karine Minaif; Ionescu, Tudor Mihai; Cunha, Marcelo Livorsi da; Baroni, Ronaldo Hueb; Garcia, Marcio Ricardo Taveira; Wagner, Jairo; Campos, Guilherme de Carvalho; Nogueira, Solange Amorim; Guerra, Elaine Gonçalves; Amaro, Edson

    2017-01-01

    In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. RESUMO Nos últimos anos, imagens médicas com tecnologias híbridas tornaram-se amplamente aceitas e utilizadas na prática clínica. O PET/RM possui vantagens importantes, incluindo excelentes contrastes e resolução, e menor radiação ionizante, em comparação ao PET/TC. Por isto, é uma modalidade promissora para exames de imagem de pacientes oncológicos, para avaliar o cérebro, cabeça e pescoço, o fígado e a pelve. O objetivo deste artigo foi analisar as situações clínicas que se beneficiariam de exames de PET/RM a partir de uma casuística. Destacamos o potencial desta técnica se tornar o método de imagem de escolha para doenças neurológicas e oncológicas que envolvam partes moles. Os aspectos clínicos de PET/RM e sua aplicação aos casos clínicos são ilustrados com exemplos da experiência inicial dos autores.

  20. Musculoskeletal infection imaging using 99Tcm-ciprofloxacin: preliminary observations

    International Nuclear Information System (INIS)

    Choong, K.K.L.; Kumar, V.; Gruenewald, S.M.; Larcos, G.; Farlow, D.C.

    1999-01-01

    Full text: Clinically available infection imaging techniques employing labelled leukocytes (WBC) and gallium citrate are sensitive for inflammation but often lack specificity for infection. 99 Tc m -ciprofloxacin (CIPRO), a labelled broad-spectrum antibiotic, is potentially more specific for infection. We present the CIPRO findings from 13 pts (8 M; 5 F; mean age 58 years) referred with possible current musculoskeletal sepsis. WBC were performed in 10 pts and temporally preceded CIPRO in 7. The average time between scans was 3 days. Eleven of the 13 pts had a prior history of documented infection secondary to trauma or joint surgery. All received antibiotics at some stage prior to CIPRO with 10 on antibiotics at the time of the scan. Final diagnosis of infection (diagnosed in 7 pts) was based on microbiological results from swabs and surgical specimens (7 pts) or the clinical course over the subsequent months (6 pts). CIPRO correctly identified 10/13 pts (77%) as having infection or no infection compared to 6/10 (60%) using WBC (P = N.S.). CIPRO and WBC were concordant in 7/10 pts. Discordant results were due to 1 false-positive CIPRO, 2 false-positive WBC. Scan accuracy in both groups may be affected by the inclusion of a patient with an equivocal diagnosis of infection; and the timing of the scans. Our preliminary observations are: (1) CIPRO is a promising diagnostic agent for musculoskeletal sepsis deserving further evaluation. (2) CIPRO appears at least as accurate as WBC but with significant preparation advantages. (3) Optimal CIPRO scanning time yet to be determined but should be at least 3-4 h post-injection to lessen blood pool effect

  1. A CT-ultrasound-coregistered augmented reality enhanced image-guided surgery system and its preliminary study on brain-shift estimation

    International Nuclear Information System (INIS)

    Huang, C H; Hsieh, C H; Lee, J D; Huang, W C; Lee, S T; Wu, C T; Sun, Y N; Wu, Y T

    2012-01-01

    With the combined view on the physical space and the medical imaging data, augmented reality (AR) visualization can provide perceptive advantages during image-guided surgery (IGS). However, the imaging data are usually captured before surgery and might be different from the up-to-date one due to natural shift of soft tissues. This study presents an AR-enhanced IGS system which is capable to correct the movement of soft tissues from the pre-operative CT images by using intra-operative ultrasound images. First, with reconstructing 2-D free-hand ultrasound images to 3-D volume data, the system applies a Mutual-Information based registration algorithm to estimate the deformation between pre-operative and intra-operative ultrasound images. The estimated deformation transform describes the movement of soft tissues and is then applied to the pre-operative CT images which provide high-resolution anatomical information. As a result, the system thus displays the fusion of the corrected CT images or the real-time 2-D ultrasound images with the patient in the physical space through a head mounted display device, providing an immersive augmented-reality environment. For the performance validation of the proposed system, a brain phantom was utilized to simulate brain-shift scenario. Experimental results reveal that when the shift of an artificial tumor is from 5mm ∼ 12mm, the correction rates can be improved from 32% ∼ 45% to 87% ∼ 95% by using the proposed system.

  2. Development and preliminary experimental study on micro-stacked insulator

    International Nuclear Information System (INIS)

    Ren Chengyan; Yuan Weiqun; Zhang Dongdong; Yan Ping; Wang Jue

    2009-01-01

    High gradient insulating technology is one of the key technologies in new type dielectric wall accelerator(DWA). High gradient insulator, namely micro-stacked insulator, was developed and preliminary experimental study was done. Based on the finite element and particle simulating method, surface electric field distribution and electron movement track of micro-stacked insulator were numerated, and then the optimized design proposal was put forward. Using high temperature laminated method, we developed micro-stacked insulator samples which uses exhaustive fluorinated ethylene propylene(FEP) as dielectric layer and stainless steel as metal layer. Preliminary experiment of vacuum surface flashover in nanosecond pulse voltage was done and micro-stacked insulator exhibited favorable vacuum surface flashover performance with flashover field strength of near 180 kV/cm. (authors)

  3. Holy images on blades: unique swords from the State Hermitage Museum (preliminary publication

    Directory of Open Access Journals (Sweden)

    Vsevolod Obraztsov

    2013-12-01

    Full Text Available The focus of this article are interesting rarities from the collection of the State Hermitage Museum - swords of the 17th-18th centuries with inscriptions in Greek and Slavonic, with images of Christian saints inlaid in gold. The authors offer the general characteristics of 17 exemplars of this kind of arms which are divided into several groups according to the shape of the hilt. A brief overview of the relatively few publications on this subject includes articles by Vasilii Prokhorov (1877; data from the Index of the Medieval Department of the Imperial Hermitage published by Nikodim Kondakov (1891, a catalogue of Count Sergei Sheremetev's collection of arms compiled by Eduard Lenz (1895, and a monograph by E. Astvatsaturian on Turkish arms from the collection of the State Historical Museum (2002. The authors pay special attention to the description and analysis of two swords from the Hermit- age collection. One of them belonged to Count Michail Miloradovich, and was presented to him in 1807 from the city of Bucharest. The second sword came to the Hermitage after the Bolshevik Revolution from the Marble Palace, the residency of the Grand Dukes Konstantinovichi. Besides the traditional inscriptions and images of the Virgin with Child crowned by angels, the blade bears a unique image of Byzantine Emperor Nikephoros Phokas blessed by Jesus Christ with both hands. There are also two cartouches with quotations from Psalms in Greek. The extremely rich décor of this sword and the unique depiction of the Byzantine Emperor leave no doubt that they were made on a special order. The authors connect the sword to the Greek Project initiated by the Russian Empress Catherine the Great. The main idea of the project was a restoration of the Byzantine Empire with Constantinople-Istanbul as its capital, where Grand Duke Konstantin, Catherine the Great's grandchild, would be ascended to the throne. This article is a preliminary publication of a project in process

  4. Multifractionated image-guided and stereotactic intensity-modulated radiotherapy of paraspinal tumors: A preliminary report

    International Nuclear Information System (INIS)

    Yamada, Yoshiya; Lovelock, D. Michael; Yenice, Kamil M.; Bilsky, Mark H.; Hunt, Margaret A.; Zatcky, Joan; Leibel, Steven A.

    2005-01-01

    irradiated patients, respectively. More than 90% of patients experienced palliation from pain, weakness, or paresthesia; 75% and 81% of secondary and primary lesions, respectively, exhibited local control at the time of last follow-up. No cases of radiation-induced myelopathy or radiculopathy have thus far been encountered. Conclusions: Precision stereotactic and image-guided paraspinal IMRT allows the delivery of high doses of radiation in multiple fractions to tumors within close proximity to the spinal cord while respecting cord tolerance. Although preliminary, the clinical results are encouraging

  5. Predictors of orthorexic behaviours in patients with eating disorders: a preliminary study.

    Science.gov (United States)

    Brytek-Matera, Anna; Rogoza, Radosław; Gramaglia, Carla; Zeppegno, Patrizia

    2015-10-15

    The construct of orthorexia in eating disorders (EDs) has received very little attention despite clinical observations of a possible overlap between the two. The aim of this study was: 1) to assess orthorexic behaviours, eating disorder pathology and attitudinal body image in ED patients; 2) to identify possible predictors of orthorexia nervosa among ED patients. Fifty-two women diagnosed with EDs were recruited. Patients' assessment included the following: the ORTO-15 test (Polish version) for orthorexic behaviours; the Eating Attitude Test-26 (EAT-26) to identify ED symptoms; the Multidimensional Body-Self Relations Questionnaire (Polish version) to assess body image. A latent class analysis was performed and differences between identified classes were assessed. The main differences concerned weight, ED pathology and orthorexic behaviours within the same group of ED patients. In order to examine predictors of orthorexia nervosa, we investigated a structural equation model, which excellently fitted to the data (χ(2)(17) = 23.05; p = .148; CFI = .962; RMSEA = .08; p = .25; SRMR = .05). In ED patients, orthorexic behaviour was negatively predicted by eating pathology, weight concern, health orientation and appearance orientation. The assessment of the orthorexia construct in EDs may add to the paucity of studies about this issue and may help to clarify the relationship between the two. Differences and similarities seem to exist between these disorders, and may benefit from specific treatment approaches. Moreover, these preliminary findings open tracks for future research in the field of the psychology of eating.

  6. Preliminary study on the correlation between color measurement of dyed polyester and its image files

    Science.gov (United States)

    Park, Y. K.; Park, Y. C.

    2017-10-01

    As the internet becomes more popular, buyers send image files to manufacturers instead of sending swatches. However, this method may cause problems because different from the monitor between the buyer and the manufacturer, and also there is a problem depending on the light source. In order to overcome these problems, we investigated the relationship between color measurement values of dyed fabrics and RGB values of image files. The RGB values of image files tended to decrease with increasing dye concentration in all three colors. Correlation between RGB values and a*, b* values was observed at low concentration, but there was little correlation at high concentration. In the case of yellow color, there is no correlation between the L*a*b* values obtained from the dyed fabric and RGB values obtained from the image file.

  7. Oxygenates in automotive fuels. Consequence analysis - preliminary study

    International Nuclear Information System (INIS)

    Brandberg, Aa.; Saevbark, B.

    1994-01-01

    Oxygenates is used in gasoline due to several reasons. They are added as high-octane components in unleaded gasoline and as agents to reduce the emission of harmful substances. Oxygenates produced from biomass might constitute a coming market for alternative fuels. This preliminary study describes the prerequisites and consequences of such an oxygenate utilization. 39 refs, 9 figs, 5 tabs

  8. Preliminary Study on the Enhancement of Reconstruction Speed for Emission Computed Tomography Using Parallel Processing

    International Nuclear Information System (INIS)

    Park, Min Jae; Lee, Jae Sung; Kim, Soo Mee; Kang, Ji Yeon; Lee, Dong Soo; Park, Kwang Suk

    2009-01-01

    Conventional image reconstruction uses simplified physical models of projection. However, real physics, for example 3D reconstruction, takes too long time to process all the data in clinic and is unable in a common reconstruction machine because of the large memory for complex physical models. We suggest the realistic distributed memory model of fast-reconstruction using parallel processing on personal computers to enable large-scale technologies. The preliminary tests for the possibility on virtual machines and various performance test on commercial super computer, Tachyon were performed. Expectation maximization algorithm with common 2D projection and realistic 3D line of response were tested. Since the process time was getting slower (max 6 times) after a certain iteration, optimization for compiler was performed to maximize the efficiency of parallelization. Parallel processing of a program on multiple computers was available on Linux with MPICH and NFS. We verified that differences between parallel processed image and single processed image at the same iterations were under the significant digits of floating point number, about 6 bit. Double processors showed good efficiency (1.96 times) of parallel computing. Delay phenomenon was solved by vectorization method using SSE. Through the study, realistic parallel computing system in clinic was established to be able to reconstruct by plenty of memory using the realistic physical models which was impossible to simplify

  9. Comparison of Ga-68 DOTA-TATE and Ga-68 DOTA-LAN PET/CT imaging in the same patient group with neuroendocrine tumours: preliminary results.

    Science.gov (United States)

    Demirci, Emre; Ocak, Meltem; Kabasakal, Levent; Araman, Ahmet; Ozsoy, Yildiz; Kanmaz, Bedii

    2013-08-01

    Recent studies have suggested that PET imaging with Ga-68-labelled DOTA-somatostatin analogues such as octreotide and octreotate is useful in diagnosing neuroendocrine tumours (NETs) and has superior value over both computed tomography and planar and SPECT somatostatin receptor scintigraphy. The aim of the present study was to evaluate the role of Ga-68 DOTA-lanreotide (Ga-68-DOTA-LAN) in patients with somatostatin receptor (sst)-expressing tumours and to compare the results of Ga-68 DOTA-D-Phe1-Tyr3-octreotate (Ga-68-DOTA-TATE) in the same patient population. Twelve patients with NETs who were referred to our department for somatostatin receptor scintigraphy were included in the study. There were four patients with well-differentiated neuroendocrine tumour (WDNET) grade 1, two patients with WDNET grade 2, and three patients with poorly differentiated neuroendocrine carcinoma (PDNEC) grade 3. There was also one patient with medullary thyroid cancer, one patient with meningioma and one patient with MEN-1. All patients underwent two consecutive PET imaging studies with Ga-68-DOTA-TATE and Ga-68 DOTA-LAN. All images were evaluated visually, and maximum standardized uptake value was calculated for quantitative evaluation. On visual examination of maximum intensity projection images, GA-68 DOTA-LAN was seen to have high background activity and high bone marrow uptake. Both tracers defined 67 lesions. Ga-68 DOTA-TATE images revealed 63 (94%) clearly defined lesions, missing four lesions. In contrast, Ga-68 DOTA-LAN images defined only 23 (44%) lesions, missing 44 (56%) lesions. Thirty-two bone lesions were detected on Ga-68-DOTA-TATE images. Among them, only 11 (34%) were positive on Ga-68 DOTA-LAN images, whereas 21 (66%) were negative. When we evaluated liver, mediastinum and gastrointestinal tract lesions, Ga-68 DOTA-LAN was seen to be positive for 12 (34%) lesions and negative for 23 (66%) lesions. Although the results are preliminary, the image quality obtained by

  10. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    International Nuclear Information System (INIS)

    Bartoli, Antonietta; Belcari, Nicola; Stark, Daniela; Hoehnemann, Sabine; Piel, Markus; Jennewein, Marc; Schmitt, Ulrich; Tillmanns, Julia; Thews, Oliver; Hiemke, Christoph; Roesch, Frank; Del Guerra, Alberto

    2006-01-01

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm 2 of YAlO 3 :Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm 3 and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities

  11. Preliminary Study of a Piston Pump for Cryogenic Fluids

    Science.gov (United States)

    Biermann, Arnold E.; Kohl, Robert C.

    1959-01-01

    Preliminary data are presented covering the performance of a low-speed, five-cylinder piston pump designed for handling boiling hydrogen. This pump was designed for a flow of 55 gallons per minute at 240 rpm with a discharge pressure of 135 pounds per square inch. Tests were made using JP-4 fuel, liquid nitrogen, and liquid hydrogen. Pump delivery and endurance characteristics were satisfactory for the range of operation covered. In connection with the foregoing pump development, the cavitation characteristics of a preliminary visual model, glass-cylinder pump and of a simple reciprocating disk were studied. Subcooling of approximately 0.60 F was obtained from the cavitation produced by reciprocating a disk in boiling nitrogen and in boiling water. The subcooling obtained in a similar manner with liquid hydrogen was somewhat less.

  12. Measurement of pressure ridges in SAR images of sea ice - Preliminary results on scattering theory

    Science.gov (United States)

    Vesecky, J. F.; Smith, M. P.; Daida, J. M.; Samadani, R.; Camiso, J. C.

    1992-01-01

    Sea ice ridges and keels (hummocks and bummocks) are important in sea ice research for both scientific and practical reasons. A long-term objective is to make quantitative measurements of sea ice ridges using synthetic aperture radar (SAR) images. The preliminary results of a scattering model for sea ice ridge are reported. The approach is through the ridge height variance spectrum Psi(K), where K is the spatial wavenumber, and the two-scale scattering model. The height spectrum model is constructed to mimic height statistics observed with an airborne optical laser. The spectrum model is used to drive a two-scale scattering model. Model results for ridges observed at C- and X-band yield normalized radar cross sections that are 10 to 15 dB larger than the observed cross sections of multiyear ice over the range of angles of incidence from 10 to 70 deg.

  13. Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

    International Nuclear Information System (INIS)

    Falco, Maria Daniela; Fontanarosa, Davide; Miceli, Roberto; Carosi, Alessandra; Santoni, Riccardo; D'Andrea, Marco

    2011-01-01

    Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4 o . For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22 o ). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be

  14. Preliminary study on the establishment of the radionuclide declaration methods for radionuclides in LILW radioactive waste

    International Nuclear Information System (INIS)

    Hwang, K. H.; Lee, K. J.; Jung, C. W.

    2003-01-01

    The preliminary study on declaration methods has been done for each radionuclide in LILW radwaste drum in Korean NPPs. View from the preliminary establishment of radio nuclide declaration methods, The selection of assessment target nuclide through the qualitative method and preliminary criteria for routine declaration methods in each radio nuclide was derived. First of all, selection criteria and preliminary assessment method for each target radionuclide was surveyed and investigated. And, the selection criteria and selected the target radio nuclides from the basis on criteria was derived. And the preliminary suggestion about the declaration methods for each target radio nuclide was established

  15. Online gaming dependency: a preliminary study in China.

    Science.gov (United States)

    Peng, Wei; Liu, Ming

    2010-06-01

    Based on theories and previous studies on problematic Internet use, we propose a model to better understand the contributors to and consequences of online gaming dependency. A preliminary study was conducted through a survey of online gamers in China. The results of path analysis found that maladaptive cognitions, shyness, and depression are positively related to online gaming dependency. Online gaming dependency was also positively related to different types of negative life outcomes. The findings of this study have implications for the prevention and treatment of addictive online gaming.

  16. Preliminary study on the dye removal efficacy of immobilized marine ...

    African Journals Online (AJOL)

    Preliminary study on the dye removal efficacy of immobilized marine and freshwater microalgal beads from textile wastewater. SD Kumar, P Santhanam, R Nandakumar, S Anath, B Balaji Prasath, A Shenbaga Devi, S Jeyanthi, T Jayalakshima, P Ananthi ...

  17. Facial image identification using Photomodeler

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Andersen, Marie; Lauritsen, Helle Petri

    2003-01-01

    consist of many images of the same person taken from different angles. We wanted to see if it was possible to combine such a suite of images in useful 3-D renderings of facial proportions.Fifteen male adults were photographed from four different angles. Based on these photographs, a 3-D wireframe model......We present the results of a preliminary study on the use of 3-D software (Photomodeler) for identification purposes. Perpetrators may be photographed or filmed by surveillance systems. The police may wish to have these images compared to photographs of suspects. The surveillance imagery will often...

  18. Hydrogen Gas Retention and Release from WTP Vessels: Summary of Preliminary Studies

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Phillip A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bontha, Jagannadha R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Daniel, Richard C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mahoney, Lenna A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rassat, Scot D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wells, Beric E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bao, Jie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Boeringa, Gregory K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Buchmiller, William C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Burns, Carolyn A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chun, Jaehun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Karri, Naveen K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Li, Huidong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tran, Diana N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) is currently being designed and constructed to pretreat and vitrify a large portion of the waste in the 177 underground waste storage tanks at the Hanford Site. A number of technical issues related to the design of the pretreatment facility (PTF) of the WTP have been identified. These issues must be resolved prior to the U.S. Department of Energy (DOE) Office of River Protection (ORP) reaching a decision to proceed with engineering, procurement, and construction activities for the PTF. One of the issues is Technical Issue T1 - Hydrogen Gas Release from Vessels (hereafter referred to as T1). The focus of T1 is identifying controls for hydrogen release and completing any testing required to close the technical issue. In advance of selecting specific controls for hydrogen gas safety, a number of preliminary technical studies were initiated to support anticipated future testing and to improve the understanding of hydrogen gas generation, retention, and release within PTF vessels. These activities supported the development of a plan defining an overall strategy and approach for addressing T1 and achieving technical endpoints identified for T1. Preliminary studies also supported the development of a test plan for conducting testing and analysis to support closing T1. Both of these plans were developed in advance of selecting specific controls, and in the course of working on T1 it was decided that the testing and analysis identified in the test plan were not immediately needed. However, planning activities and preliminary studies led to significant technical progress in a number of areas. This report summarizes the progress to date from the preliminary technical studies. The technical results in this report should not be used for WTP design or safety and hazards analyses and technical results are marked with the following statement: “Preliminary Technical Results for Planning – Not to be used for WTP Design

  19. Preliminary study of soil permeability properties using principal component analysis

    Science.gov (United States)

    Yulianti, M.; Sudriani, Y.; Rustini, H. A.

    2018-02-01

    Soil permeability measurement is undoubtedly important in carrying out soil-water research such as rainfall-runoff modelling, irrigation water distribution systems, etc. It is also known that acquiring reliable soil permeability data is rather laborious, time-consuming, and costly. Therefore, it is desirable to develop the prediction model. Several studies of empirical equations for predicting permeability have been undertaken by many researchers. These studies derived the models from areas which soil characteristics are different from Indonesian soil, which suggest a possibility that these permeability models are site-specific. The purpose of this study is to identify which soil parameters correspond strongly to soil permeability and propose a preliminary model for permeability prediction. Principal component analysis (PCA) was applied to 16 parameters analysed from 37 sites consist of 91 samples obtained from Batanghari Watershed. Findings indicated five variables that have strong correlation with soil permeability, and we recommend a preliminary permeability model, which is potential for further development.

  20. PTSD and Impaired Eye Expression Recognition: A Preliminary Study

    Science.gov (United States)

    Schmidt, Jakob Zeuthen; Zachariae, Robert

    2009-01-01

    This preliminary study examined whether posttraumatic stress disorder (PTSD) was related to difficulties in identifying the mental states of others in a group of refugees. Sixteen Bosnian refugees, referred to treatment in an outpatient treatment center for survivors of torture and war-related trauma in Denmark (CETT), were compared to 16 non-PTSD…

  1. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  2. Preliminary study for small animal preclinical hadrontherapy facility

    Science.gov (United States)

    Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.

    2017-02-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  3. Preliminary study for small animal preclinical hadrontherapy facility

    International Nuclear Information System (INIS)

    Russo, G.; Pisciotta, P.; Cirrone, G.A.P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M.C.; Cuttone, G.

    2017-01-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  4. Spirituality and the Events of September 11: A Preliminary Study

    Science.gov (United States)

    Briggs, Michele Kielty; Apple, Kevin J.; Aydlett, Ann E.

    2004-01-01

    Personal crises have been associated with spiritual growth. Sparked by the global response to the crisis of September 11, 2001, this study examined the relationship of spirituality and the September 11 tragedy using a sample of convenience from a college student population. This preliminary study used an experimental design to examine various…

  5. Sodium MR imaging of human brain neoplasms. A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Shu; Yoshikawa, Kohki; Takakura, Kintomo; Iio, Masahiro

    1988-08-01

    We reported the experience of the sodium magnetic resonance imaging of 5 patients with brain tumors (4 astrocytomas and 1 craniopharyngioma), using a Siemens 1.5 Tesla superconductive magnet. We used two-dimensional Fourier imaging with a spin-echo scanning sequence (and with the repetition time of 140 msec and the echo time of 11 - 14 msec). The radiofrequency was maintained at 17 MHz. Sodium MR imaging was achieved with a 64 x 64 data acquisition (30 mm slice thickness) in 19.1 min. On the sodium MRI, all four astrocytomas, along with the eye balls and the cerebrospinal fluid spaces, appeared as high-intensity areas. Peritumoral edema is also visualized as highly intense, so that it is difficult to discriminate tumor extent from the surrounding edema. Our comparative studies with malignant glioma cases using the same equipment are needed to clarify the relationship between sodium signal intensities and the malignancy of gliomas, and to evaluate the potential clinical utility of sodium MRI. A craniopharyngioma than contained a yellowish cystic fluid with a sodium concentration as high as CSF was shown on sodium MRI as a mass with highly intense signals. The ability to differentiate extracellular from intracellular sodium, that has been studied by several investigators, would greatly augment the clinical specificity of MR imaging.

  6. Non-linear Ultrasound Imaging

    DEFF Research Database (Denmark)

    Du, Yigang

    .3% relative to the measurement from a 1 inch diameter transducer. A preliminary study for harmonic imaging using synthetic aperture sequential beamforming (SASB) has been demonstrated. A wire phantom underwater measurement is made by an experimental synthetic aperture real-time ultrasound scanner (SARUS......) with a linear array transducer. The second harmonic imaging is obtained by a pulse inversion technique. The received data is beamformed by the SASB using a Beamformation Toolbox. In the measurements the lateral resolution at -6 dB is improved by 66% compared to the conventional imaging algorithm. There is also...... a 35% improvement for the lateral resolution at -6 dB compared with the sole harmonic imaging and a 46% improvement compared with merely using the SASB....

  7. Preliminary results of a new workflow for MRI/CT-based image-guided brachytherapy in cervical carcinoma.

    Science.gov (United States)

    Nemoto, Miho Watanabe; Iwai, Yuma; Togasaki, Gentaro; Kurokawa, Marie; Harada, Rintarou; Kobayashi, Hiroki; Uno, Takashi

    2017-12-01

    We propose a method of image-guided brachytherapy (IGBT) that combines MRI-based target volume delineation for the first fraction with CT datasets of subsequent fractions, using an automatic, applicator-based co-registration, and report our preliminary experience. The MRI of the first fraction was used for the first brachytherapy planning. For each subsequent brachytherapy fraction, after the same applicator insertion, a new CT scan with the applicator in place was obtained. The MR image set was registered to the subsequent brachytherapy treatment planning CT using the applicator for rigid body registration. To demonstrate the registration quality, we used here the Dice index as a measurement of tandem delineation overlap between CT and MRI. The median Dice index was 0.879 (range 0.610-0.932), which indicated that the contours on CT and MRI fitted well. With this combination method, the median D90 of HR CTV and the calculated D2 cm 3 of the bladder, rectum, and sigmoid in each fraction were 7.2 (4.0-10.4), 5.9 (2.3-7.7), 4.0 (1.9-6.7), and 3.8 (0.6-7.2) Gy, respectively. Our described method of MRI-guided IGBT offers a practical option for the benefits of target delineation.

  8. The preliminary study of the blood perfusion and ammonia metabolism of pituitary using dynamic 13N-NH3 PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; Qiao Suixian; Chen Liguang; Luo Yaowu; Liu Bin; Xu Weiping

    2002-01-01

    Objective: To preliminarily study the blood perfusion and ammonia metabolism of pituitary using dynamic 13 N-NH 3 PET imaging. Methods: 13 N-NH 3 PET imaging was performed on 21 subjects without pituitary diseases, 6 of them underwent dynamic PET imaging, and 8 of them underwent brain MRI in addition to PET. PET images were registered with MRI. Results: The pituitary could be clearly seen in 13 N-NH 3 PET images, and being confirmed by PET/MRI image fusion. The size of pituitary was (1.07 +- 0.17) cm x (1.09 +- 0.15) cm x (1.14 +- 0.17) cm, the standard uptake value (SUV) was 3.84 +- 1.75, and the radioactivity ratio of pituitary to thalamus was 1.35 +- 0.63. Pituitary image was seen at 10 s after the internal carotid was seen in dynamic 13 N-NH 3 PET imaging. 13 N-NH 3 was retained in pituitary, and was hardly cleaned out within 20 min. The radioactivity ratio of pituitary to internal carotid was 0.75 +- 0.13 when the radioactivity of internal carotid was at its highest level. Conclusions: The blood flow and ammonia metabolism of pituitary can be observed with dynamic 13 N-NH 3 PET imaging. Ammonia is highly extracted by pituitary, and metabolized in pituitary cells

  9. A preliminary study on the relevancy of sustainable building design ...

    African Journals Online (AJOL)

    This preliminary study aims to explore the relationship between sustainable building design paradigms and commercial property depreciation, to assist in the understanding of sustainable building design impact towards commercial building value and rental de employs the qualitative method and analyses valuers' current ...

  10. A Preliminary Study toward Consistent Soil Moisture from AMSR2

    NARCIS (Netherlands)

    Parinussa, R.M.; Holmes, T.R.H.; Wanders, N.; Dorigo, W.A.; de Jeu, R.A.M.

    2015-01-01

    A preliminary study toward consistent soil moisture products from the Advanced Microwave Scanning Radiometer 2 (AMSR2) is presented. Its predecessor, the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E), has providedEarth scientists with a consistent and continuous global

  11. Effectiveness of diffusion tensor imaging in assessing disease severity in Duchenne muscular dystrophy: preliminary study

    International Nuclear Information System (INIS)

    Ponrartana, Skorn; Hu, Houchun Harry; Ramos-Platt, Leigh; Wren, Tishya Anne Leong; Gilsanz, Vicente; Perkins, Thomas Gardner; Chia, Jonathan Mawlin

    2015-01-01

    There is currently a lack of suitable objective endpoints to measure disease progression in Duchenne muscular dystrophy (DMD). Emerging research suggests that diffusion tensor imaging (DTI) has potential as an outcome measure for the evaluation of skeletal muscle injury. The objective of this study was to evaluate the potential of DTI as quantitative magnetic resonance imaging (MRI) markers of disease severity in DMD. Thirteen consecutive boys (8.9 years ± 3.0 years) with DMD were evaluated using DTI. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were compared with clinical outcome measures of manual muscle testing and MRI determinations of muscle fat fraction (MFF) in the right lower extremity. Both MRI measures of FA and ADC strongly correlated with age and muscle strength. Values for FA positively correlated with age and negatively correlated with muscle strength (r = 0.78 and -0.96; both P ≤ 0.002) while measures of ADC negatively correlated age, but positively correlated with muscle strength (r = -0.87 and 0.83; both P ≤ 0.0004). Additionally, ADC and FA strongly correlated with MFF (r = -0.891 and 0.894, respectively; both P ≤ 0.0001). Mean MMF was negatively correlated with muscle strength (r = -0.89, P = 0.0001). DTI measures of muscle structure strongly correlated with muscle strength and adiposity in boys with DMD in this pilot study, although these markers may be more reflective of fat replacement rather than muscle damage in later stages of the disease. Further studies in presymptomatic younger children are needed to assess the ability of DTI to detect early changes in DMD. (orig.)

  12. Effectiveness of diffusion tensor imaging in assessing disease severity in Duchenne muscular dystrophy: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ponrartana, Skorn; Hu, Houchun Harry [Children' s Hospital Los Angeles, Department of Radiology, Los Angeles, CA (United States); Ramos-Platt, Leigh [Children' s Hospital Los Angeles, Department of Neurology, Los Angeles, CA (United States); Wren, Tishya Anne Leong; Gilsanz, Vicente [Children' s Hospital Los Angeles, Department of Radiology, Los Angeles, CA (United States); Children' s Hospital Los Angeles, Department of Orthopaedic Surgery, Los Angeles, CA (United States); Perkins, Thomas Gardner; Chia, Jonathan Mawlin [Philips Healthcare North America, Cleveland, OH (United States)

    2015-04-01

    There is currently a lack of suitable objective endpoints to measure disease progression in Duchenne muscular dystrophy (DMD). Emerging research suggests that diffusion tensor imaging (DTI) has potential as an outcome measure for the evaluation of skeletal muscle injury. The objective of this study was to evaluate the potential of DTI as quantitative magnetic resonance imaging (MRI) markers of disease severity in DMD. Thirteen consecutive boys (8.9 years ± 3.0 years) with DMD were evaluated using DTI. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were compared with clinical outcome measures of manual muscle testing and MRI determinations of muscle fat fraction (MFF) in the right lower extremity. Both MRI measures of FA and ADC strongly correlated with age and muscle strength. Values for FA positively correlated with age and negatively correlated with muscle strength (r = 0.78 and -0.96; both P ≤ 0.002) while measures of ADC negatively correlated age, but positively correlated with muscle strength (r = -0.87 and 0.83; both P ≤ 0.0004). Additionally, ADC and FA strongly correlated with MFF (r = -0.891 and 0.894, respectively; both P ≤ 0.0001). Mean MMF was negatively correlated with muscle strength (r = -0.89, P = 0.0001). DTI measures of muscle structure strongly correlated with muscle strength and adiposity in boys with DMD in this pilot study, although these markers may be more reflective of fat replacement rather than muscle damage in later stages of the disease. Further studies in presymptomatic younger children are needed to assess the ability of DTI to detect early changes in DMD. (orig.)

  13. Automated Spot Mammography for Improved Imaging of Dense Breasts

    National Research Council Canada - National Science Library

    Goodsitt, Mitchell M

    2004-01-01

    ... image that better distinguishes masses from overlapping tissues. Preliminary studies with a prototype device and breast simulating test objects showed promise, but spot compression didn't always separate the tissues as much as desired...

  14. Resting-state functional magnetic resonance imaging for surgical planning in pediatric patients: a preliminary experience.

    Science.gov (United States)

    Roland, Jarod L; Griffin, Natalie; Hacker, Carl D; Vellimana, Ananth K; Akbari, S Hassan; Shimony, Joshua S; Smyth, Matthew D; Leuthardt, Eric C; Limbrick, David D

    2017-12-01

    OBJECTIVE Cerebral mapping for surgical planning and operative guidance is a challenging task in neurosurgery. Pediatric patients are often poor candidates for many modern mapping techniques because of inability to cooperate due to their immature age, cognitive deficits, or other factors. Resting-state functional MRI (rs-fMRI) is uniquely suited to benefit pediatric patients because it is inherently noninvasive and does not require task performance or significant cooperation. Recent advances in the field have made mapping cerebral networks possible on an individual basis for use in clinical decision making. The authors present their initial experience translating rs-fMRI into clinical practice for surgical planning in pediatric patients. METHODS The authors retrospectively reviewed cases in which the rs-fMRI analysis technique was used prior to craniotomy in pediatric patients undergoing surgery in their institution. Resting-state analysis was performed using a previously trained machine-learning algorithm for identification of resting-state networks on an individual basis. Network maps were uploaded to the clinical imaging and surgical navigation systems. Patient demographic and clinical characteristics, including need for sedation during imaging and use of task-based fMRI, were also recorded. RESULTS Twenty patients underwent rs-fMRI prior to craniotomy between December 2013 and June 2016. Their ages ranged from 1.9 to 18.4 years, and 12 were male. Five of the 20 patients also underwent task-based fMRI and one underwent awake craniotomy. Six patients required sedation to tolerate MRI acquisition, including resting-state sequences. Exemplar cases are presented including anatomical and resting-state functional imaging. CONCLUSIONS Resting-state fMRI is a rapidly advancing field of study allowing for whole brain analysis by a noninvasive modality. It is applicable to a wide range of patients and effective even under general anesthesia. The nature of resting

  15. Preliminary study and Identification of insects' species of forensic ...

    African Journals Online (AJOL)

    The proper identification of the insect and arthropod species of forensic importance is the most crucial element in the field of forensic entomology. The main objective in this study was the identification of insects' species of forensic importance in Urmia (37°, 33 N. and 45°, 4, 45 E.) and establishment of a preliminary ...

  16. Preliminary study on chicken feather protein-based wood adhesives

    Science.gov (United States)

    Zehui Jiang; Daochun Qin; Chung-Yun Hse; Monlin Kuo; Zhaohui Luo; Ge Wang; Yan Yu

    2008-01-01

    The objective of this preliminary study was to partially replace phenol in the synthesis of phenol-formaldehyde resin with feather protein. Feather protein–based resins, which contained one part feather protein and two parts phenol, were formulated under the conditions of two feather protein hydrolysis methods (with and without presence of phenol during...

  17. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided....

  18. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

    Science.gov (United States)

    Armstrong, Ian S; Saint, Kimberley J; Tonge, Christine M; Arumugam, Parthiban

    2017-04-01

    There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.

  19. Intraarterial Ultrasound in Pancreatic Cancer: Feasibility Study and Preliminary Results

    International Nuclear Information System (INIS)

    Larena-Avellaneda, Axel; Timm, Stephan; Kickuth, Ralph; Kenn, Werner; Steger, Ulrich; Jurowich, Christian; Germer, Christoph-Thomas

    2010-01-01

    Despite technological advances in computed tomography (CT) and magnetic resonance imaging, the involvement of the celiac or mesenteric artery in pancreatic cancer remains uncertain in many cases. Infiltration of these vessels is important in making decisions about therapy choices but often can only be definitively determined through laparotomy. Local (intraarterial) ultrasound may increase diagnostic accuracy. Using the Volcano intravascular ultrasound (IVUS) system, we applied a transfemoral method to scan the celiac and mesenteric arteries directly intraarterial. This technique was used in five patients with suspected pancreatic cancer. Technical success was achieved in all cases. In one case, a short dissection of the mesenteric artery occurred but could be managed interventionally. In tumors that did not contact with the vessels, IVUS was unable to display the tissue pathology. Our main interest was the infiltration of the arteries. In one case, infiltration was certain in the CT scan but uncertain in two patients. In the latter two cases, IVUS correctly predicted infiltration in one and freedom from tumor in the other case. In our preliminary study, IVUS correctly predicted arterial infiltration in all cases. IVUS did not provide new information when the tumor was far away from the vessel. Compared with IVUS in the portal vein, the information about the artery is more detailed, and the vessel approach is easier. These results encouraged us to design a prospective study to evaluate the sensitivity and specificity of this method.

  20. A preliminary conceptual design study for Korean fusion DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keeman, E-mail: kkeeman@nfri.re.kr [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Kim, Hyoung Chan; Oh, Sangjun; Lee, Young Seok; Yeom, Jun Ho; Im, Kihak; Lee, Gyung-Su [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Neilson, George; Kessel, Charles; Brown, Thomas; Titus, Peter [Princeton Plasma Physics Laboratory, Princeton University, Princeton, NJ 08543 (United States)

    2013-10-15

    Highlights: ► Perform a preliminary conceptual study for a steady-state Korean DEMO reactor. ► Present design guidelines and requirements of Korean DEMO reactor. ► Present a preliminary design of TF (toroidal field) and CS (central solenoid) magnet. ► Present a preliminary result of the radial build scheme of Korean DEMO reactor. -- Abstract: As the ITER is being constructed, there is a growing anticipation for an earlier realization of fusion energy, so called fast-track approach. Korean strategy for fusion energy can be regarded as a fast-track approach and one special concept discussed in this paper is a two-stage development plan. At first, a steady-state Korean DEMO Reactor (K-DEMO) is designed not only to demonstrate a net electricity generation and a self-sustained tritium cycle, but also to be used as a component test facility. Then, at its second stage, a major upgrade is carried out by replacing in-vessel components in order to show a net electric generation on the order of 300 MWe and the competitiveness in cost of electricity (COE). The major radius is designed to be just below 6.5 m, considering practical engineering feasibilities. By using high performance Nb{sub 3}Sn-based superconducting cable currently available, high magnetic field at the plasma center above 8 T can be achieved. A design concept for TF magnets and radial builds for the K-DEMO considering a vertical maintenance scheme, are presented together with preliminary design parameters.

  1. Photoacoustic tomography of joints aided by an Etanercept-conjugated gold nanoparticle contrast agent-an ex vivo preliminary rat study

    International Nuclear Information System (INIS)

    Chamberland, David L; Agarwal, Ashish; Kotov, Nicholas; Fowlkes, J Brian; Carson, Paul L; Wang Xueding

    2008-01-01

    Monitoring of anti-rheumatic drug delivery in experimental models and in human diseases would undoubtedly be very helpful for both basic research and clinical management of inflammatory diseases. In this study, we have investigated the potential of an emerging hybrid imaging technology-photoacoustic tomography-in noninvasive monitoring of anti-TNF drug delivery. After the contrast agent composed of gold nanorods conjugated with Etanercept molecules was produced, ELISA experiments were performed to prove the conjugation and to show that the conjugated anti-TNF-α drug was biologically active. PAT of ex vivo rat tail joints with the joint connective tissue enhanced by intra-articularly injected contrast agent was conducted to examine the performance of PAT in visualizing the distribution of the gold-nanorod-conjugated drug in articular tissues. By using the described system, gold nanorods with a concentration down to 1 pM in phantoms or 10 pM in biological tissues can be imaged with good signal-to-noise ratio and high spatial resolution. This study demonstrates the feasibility of conjugating TNF antagonist pharmaceutical preparations with gold nanorods, preservation of the mechanism of action of TNF antagonist along with preliminary evaluation of novel PAT technology in imaging optical contrast agents conjugated with anti-rheumatic drugs. Further in vivo studies on animals are warranted to test the specific binding between such conjugates and targeted antigen in joint tissues affected by inflammation

  2. Preliminary experiments on quantification of skin condition

    Science.gov (United States)

    Kitajima, Kenzo; Iyatomi, Hitoshi

    2014-03-01

    In this study, we investigated a preliminary assessment method for skin conditions such as a moisturizing property and its fineness of the skin with an image analysis only. We captured a facial images from volunteer subjects aged between 30s and 60s by Pocket Micro (R) device (Scalar Co., Japan). This device has two image capturing modes; the normal mode and the non-reflection mode with the aid of the equipped polarization filter. We captured skin images from a total of 68 spots from subjects' face using both modes (i.e. total of 136 skin images). The moisture-retaining property of the skin and subjective evaluation score of the skin fineness in 5-point scale for each case were also obtained in advance as a gold standard (their mean and SD were 35.15 +/- 3.22 (μS) and 3.45 +/- 1.17, respectively). We extracted a total of 107 image features from each image and built linear regression models for estimating abovementioned criteria with a stepwise feature selection. The developed model for estimating the skin moisture achieved the MSE of 1.92 (μS) with 6 selected parameters, while the model for skin fineness achieved that of 0.51 scales with 7 parameters under the leave-one-out cross validation. We confirmed the developed models predicted the moisture-retaining property and fineness of the skin appropriately with only captured image.

  3. Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xiao Kun; Ni, Qian Qian; Zhou, Chang Sheng; Chen, Guo Zhong; Luo, Song; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Ashley River Tower, Division of Cardiovascular Imaging, Charleston, SC (United States); Fuller, Stephen R.; De Cecco, Carlo N. [Medical University of South Carolina, Ashley River Tower, Division of Cardiovascular Imaging, Charleston, SC (United States)

    2016-11-15

    To evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data. Patients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis ≥ 50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared. There were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively. Compared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct. (orig.)

  4. Synthetic Aperture Imaging in Medical Ultrasound

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Gammelmark, Kim; Pedersen, Morten

    2004-01-01

    with high precision, and the imaging is easily extended to real-time 3D scanning. This paper presents the work done at the Center for Fast Ultrasound Imaging in the area of SA imaging. Three areas that benefit from SA imaging are described. Firstly a preliminary in-vivo evaluation comparing conventional B...

  5. First high speed imaging of lightning from summer thunderstorms over India: Preliminary results based on amateur recording using a digital camera

    Science.gov (United States)

    Narayanan, V. L.

    2017-12-01

    For the first time, high speed imaging of lightning from few isolated tropical thunderstorms are observed from India. The recordings are made from Tirupati (13.6oN, 79.4oE, 180 m above mean sea level) during summer months with a digital camera capable of recording high speed videos up to 480 fps. At 480 fps, each individual video file is recorded for 30 s resulting in 14400 deinterlaced images per video file. An automatic processing algorithm is developed for quick identification and analysis of the lightning events which will be discussed in detail. Preliminary results indicating different types of phenomena associated with lightning like stepped leader, dart leader, luminous channels corresponding to continuing current and M components are discussed. While most of the examples show cloud to ground discharges, few interesting cases of intra-cloud, inter-cloud and cloud-air discharges will also be displayed. This indicates that though high speed cameras with few 1000 fps are preferred for a detailed study on lightning, moderate range CMOS sensor based digital cameras can provide important information as well. The lightning imaging activity presented herein is initiated as an amateur effort and currently plans are underway to propose a suite of supporting instruments to conduct coordinated campaigns. The images discussed here are acquired from normal residential area and indicate how frequent lightning strikes are in such tropical locations during thunderstorms, though no towering structures are nearby. It is expected that popularizing of such recordings made with affordable digital cameras will trigger more interest in lightning research and provide a possible data source from amateur observers paving the way for citizen science.

  6. Spatial and verbal working memory: A functional magnetic resonance imaging study

    Directory of Open Access Journals (Sweden)

    Blaž Koritnik

    2004-08-01

    Full Text Available According to numerous studies, working memory is not a unitary system. Baddeley's model of working memory includes besides central executive also two separate systems for verbal and visuo-spatial information processing. A modality- and process-specific specialization presumably exists in working memory system of the frontal lobes. In our preliminary study, we have used functional magnetic resonance imaging to study the pattern of cortical activation during spatial and verbal n-back task in six healthy subjects. A bilateral fronto-parietal cortical network was activated in both tasks. There was larger activation of right parietal and bilateral occipital areas in spatial than in vebal task. Activation of left sensorimotor area was larger in verbal compared to spatial task. No task-specific differences were found in the prefrontal cortex. Our results support the assumption that modality-specific processes exist within the working-memory system.

  7. The development of a haptic virtual reality environment to study body image and affect.

    Science.gov (United States)

    Tremblay, Line; Bouchard, Stephane; Chebbi, Brahim; Wei, Lai; Monthuy-Blanc, Johana; Boulanger, Dominic

    2013-01-01

    We report the results of a preliminary study testing the effect of participants' mood rating on visual motor performance using a haptic device to manipulate a cartoonish human body. Our results suggest that moods involving high arousal (e.g. happiness) produce larger movements whereas mood involving low arousal (e.g. sadness) produce slower speed of performance. Our results are used for the development of a new haptic virtual reality application that we briefly present here. This application is intended to create a more interactive and motivational environment to treat body image issues and for emotional communication.

  8. Production, quality control and initial imaging studies of [82mRb]RbCl for PET studies

    International Nuclear Information System (INIS)

    Rowshanfarzad, P.; Jalilian, A.R.; Kiyomarsi, M.; Sabet, M.; Karimian, A.R.; Moradkhani, S.; Mirzaii, M.

    2006-01-01

    Rubidium-82m was prepared via 15.4 MeV proton irradiation of a krypton-82 gaseous target (30% enrichment). Washing the target chamber with hot water yielded a Rb-82m containing solution, which was further purified using short column chromatography in order to remove organic/inorganic impurities. The flowthrough was formulated in normal saline for injection. Radionuclide, radiochemical and chemical purity tests were performed prior to administration to rats for imaging (radiochemical yield: 95-97%, radiochemical purity > 97%). Preliminary dual-head coincidence studies were performed to determine the distribution of [ 82m Rb]Rb in normal rats. For biodistribution studies, Rb-81 was injected to rats and tracer accumulation in heart, GI and bladder was determined after sacrification in time intervals. A yield of 1.3 GBq at EOB, 235.7 MBq/μAh was obtained. (authors)

  9. LM-OSL from single grains of quartz: A preliminary study

    DEFF Research Database (Denmark)

    Bulur, E.; Duller, G.A.T.; Solongo, S.

    2002-01-01

    the easy-to-bleach component, those with only the hard-to-bleach component, and those exhibiting all components. The results of this preliminary study show that LM-OSL experiments carried out at the single grain level may give important insights into the luminescence properties observed when viewing...

  10. Hyperspectral imaging in medicine: image pre-processing problems and solutions in Matlab.

    Science.gov (United States)

    Koprowski, Robert

    2015-11-01

    The paper presents problems and solutions related to hyperspectral image pre-processing. New methods of preliminary image analysis are proposed. The paper shows problems occurring in Matlab when trying to analyse this type of images. Moreover, new methods are discussed which provide the source code in Matlab that can be used in practice without any licensing restrictions. The proposed application and sample result of hyperspectral image analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Preliminary examples of 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes; Stuart, Matthias Bo; Tomov, Borislav Gueorguiev

    2013-01-01

    This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental ult...... as opposed to magnetic resonance imaging (MRI). The results demonstrate that the 3D TO method is capable of performing 3D vector flow imaging.......This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental...... ultrasound scanner SARUS on a flow rig system with steady flow. The vessel of the flow-rig is centered at a depth of 30 mm, and the flow has an expected 2D circular-symmetric parabolic prole with a peak velocity of 1 m/s. Ten frames of 3D vector flow images are acquired in a cross-sectional plane orthogonal...

  12. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    Energy Technology Data Exchange (ETDEWEB)

    Bartoli, Antonietta [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)]. E-mail: bartoli@df.unipi.it; Belcari, Nicola [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy); Stark, Daniela [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Hoehnemann, Sabine [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Piel, Markus [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Jennewein, Marc [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Schmitt, Ulrich [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Tillmanns, Julia [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Thews, Oliver [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Hiemke, Christoph [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Roesch, Frank [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Del Guerra, Alberto [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)

    2006-12-20

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm{sup 2} of YAlO{sub 3}:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm{sup 3} and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities.

  13. Preliminary application in teaching of medical imaging with picture archiving and communication systems

    International Nuclear Information System (INIS)

    Wei Yuqing; Hu Jian; Wang Xuejian; Cao Jun; Tong Juan; Shen Guiquan; Luo Min; Luo Song

    2003-01-01

    Objective: To evaluate PACS (picture archiving and communication systems) in the teaching of medical imaging. Methods: Large screen multimedia reading room and electronic study room were built with GE PACS and Angel RIS (radiology information system) and end-term picture-word work-station. Pictures and words of PACS were unloaded directly for teaching and teaching image bank and test image bank. Results: Large screen multimedia reading room, classroom, and electronic study room were built successfully. Valuable information of nearly 5000 patients in the teaching imaging bank of PACS was accumulated. Classic medical imaging teaching mode was changed. Real-time and multi-mode teaching were realized, and teaching effect was greatly improved. The PACS-based teaching model was accepted pleasantly by students. Conclusion: PACS is very useful to improve the teaching quality of medical imaging and it is worth to popularize

  14. Real-Time Monitoring of Occupants’ Thermal Comfort through Infrared Imaging: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Boris Pavlin

    2017-02-01

    Full Text Available Thermally comfortable indoor environments are of great importance, as modern lifestyles often require people to spend more than 20 h per day indoors. Since most of the thermal comfort models use a variety of different environmental and personal factors that need to be measured or estimated, real-time and continuous assessment of thermal comfort is often not practically feasible. This work presents a cheap and non-invasive approach based on infrared imaging for monitoring the occupants’ thermal sensation and comfort in real time. Thanks to a mechatronic device developed by the authors, the imaging is performed on the forehead skin, selected because it is always exposed to the environment and, thus, facilitating the monitoring activity in a non-invasive manner. Tests have been performed in controlled conditions on ten subjects to assess the hypothesis that the forehead temperature is correlated with subjects’ thermal sensation. This allows the exploitation of this quantity as a base for a simple monitoring of thermal comfort, which could later be tuned with an extensive experimental campaign.

  15. Preliminary study of radium-contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Healy, J.W.; Rodgers, J.C.

    1978-10-01

    A preliminary study was made of the potential radiation exposures to people from radium-226 contamination in the soil in order to provide guidance on limits to be applied in decontaminating land. Pathways included were inhalation of radium from resuspension; ingestion of radium with foods; external gamma radiation from radium daughters; inhalation of radon and daughter, both in the open air and in houses; and the intake of /sup 210/Pb and /sup 210/Po from both inhalation and ingestion. The depth of the contaminated layer is of importance for external exposure and especially for radon emanation. The most limiting pathway was found to be emanation of the radon into buildings with limiting values comparable to those found naturally in many areas.

  16. Preliminary study of radium-contaminated soils

    International Nuclear Information System (INIS)

    Healy, J.W.; Rodgers, J.C.

    1978-10-01

    A preliminary study was made of the potential radiation exposures to people from radium-226 contamination in the soil in order to provide guidance on limits to be applied in decontaminating land. Pathways included were inhalation of radium from resuspension; ingestion of radium with foods; external gamma radiation from radium daughters; inhalation of radon and daughter, both in the open air and in houses; and the intake of 210 Pb and 210 Po from both inhalation and ingestion. The depth of the contaminated layer is of importance for external exposure and especially for radon emanation. The most limiting pathway was found to be emanation of the radon into buildings with limiting values comparable to those found naturally in many areas

  17. Cardiomagnetic source imaging

    OpenAIRE

    Pesola, Katja

    2000-01-01

    Magnetocardiographic (MCG) source imaging has received increasing interest in recent years. With a high enough localization accuracy of the current sources in the heart, valuable information can be provided, e.g., for the pre-ablative evaluation of arrhythmia patients. Furthermore, preliminary studies indicate that ischemic areas, i.e. areas which are suffering from lack of oxygen, and infarcted regions could be localized from multichannel MCG recordings. In this thesis, the accuracy of cardi...

  18. Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results

    CERN Document Server

    Bennett, James R; Xu, Qiong; Yu, Hengyong; Walsh, Michael; Butler, Anthony; Butler, Phillip; Cao, Guohua; Mohs, Aaron; Wang, Ge

    2014-01-01

    Spectral CT has proven an important development in biomedical imaging, and there have been several publications in the past years demonstrating its merits in pre-clinical and clinical applications. In 2012, Xu et al. reported that near-term implementation of spectral micro-CT could be enhanced by a hybrid architecture: a narrow-beam spectral "interior" imaging chain integrated with a traditional wide-beam "global" imaging chain. This hybrid integration coupled with compressive sensing (CS)-based interior tomography demonstrated promising results for improved contrast resolution, and decreased system cost and radiation dose. The motivation for the current study is implementation and evaluation of the hybrid architecture with a first-of-its-kind hybrid spectral micro-CT system. Preliminary results confirm improvements in both contrast and spatial resolution. This technology is shown to merit further investigation and potential application in future spectral CT scanner design.

  19. A preliminary study on growth response of broiler finishers fed ...

    African Journals Online (AJOL)

    A preliminary study on growth response of broiler finishers fed processed mottle Mucuna beans ( Mucuna pruriens var. utilis ) ... They were fed diets (20% CP, 13 MJME/kg) incorporating 0%, 5% and 10% processed mottle “Mucuna” beans. A completely randomized design was used. Feed and water were supplied and ...

  20. 64Cu-PSMA-617 PET/CT Imaging of Prostate Adenocarcinoma: First In-Human Studies.

    Science.gov (United States)

    Grubmüller, Bernhard; Baum, Richard P; Capasso, Enza; Singh, Aviral; Ahmadi, Yasaman; Knoll, Peter; Floth, Andreas; Righi, Sergio; Zandieh, Shahin; Meleddu, Carlo; Shariat, Shahrokh F; Klingler, Hans Christoph; Mirzaei, Siroos

    2016-10-07

    The prostate-specific membrane antigen (PSMA) is a cell surface protein, which is overexpressed in nearly all cases of prostate cancer (PCa). PET imaging with 68 Ga-PSMA-HBED-CC has recently found widespread application in the diagnosis of recurrent PCa. In this study, the diagnostic potential of 64 Cu-labeled PSMA ligand (PSMA-617) PET in patients with PCa has been investigated. The study was conducted simultaneously at two nuclear medicine centers, Austria (Vienna, Center 1) and Germany (Bad Berka, Center 2). The patients (n = 29) included in this study were referred for PET (Center 1, 21 patients) or PET/CT (Center 2, 8 patients) imaging with either a high suspicion of recurrent disease or for possible surgical or PSMA radioligand therapy planning. PET images of the whole body were performed at 1 hour p.i. and additional images of the pelvis at 2 hours p.i. In 23 of 29 patients, at least one focus of pathological tracer uptake suspicious for primary disease in the prostate lobe or recurrent disease was detected. Among healthy organs, the salivary glands, kidneys, and liver showed the highest radiotracer uptake. Lesions suspicious for PCa were detected with excellent contrast as early as 1 hour p.i. with high detection rates even at low prostate-specific antigen (PSA) levels. The preliminary results of this study demonstrate the high potential of 64 Cu-PSMA ligand PET/CT imaging in patients with recurrent disease and in the primary staging of selected patients with progressive local disease. The acquired PET images showed an excellent resolution of the detected lesions with very high lesion-to- background contrast. Furthermore, the long half-life of 64 Cu allows distribution of the tracer to clinical PET centers that lack radiochemistry facilities for the preparation of 68 Ga-PSMA ligand (satellite concept).

  1. Preliminary neutronic study on Pu-based OTTO cycle pebble bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Setiadipura, Topan; Zuhair [National Nuclear Energy Agency of Indonesia (BATAN), Selatan (Indonesia). Center for Nuclear Reactor Technology and Safety; Irwanto, Dwi [Bandung Institute of Technology (ITB), Bandung (Indonesia). Nuclear Physics and Biophysics Research Group

    2017-12-15

    The neutron physics characteristic of Pebble Bed Reactor (PBR) allows a better incineration of plutonium (Pu). An optimized design of simple PBR might give a symbiotic solution of providing a safe energy source, effective fuel utilization shown by a higher burnup value, and incineration of Pu stockpiles. This study perform a preliminary neutronic design study of a 200 MWt Once Through Then Out (OTTO) cycle PBR with Pu-based fuel. The safety criteria of the design were represented by the per-fuel-pebble maximum power generation of 4.5 kW/pebble. In this preliminary phase, the parametric survey is limited to the heavy metal (HM) loading per pebble and the average axial speed of the fuel. An optimum high burnup of 419.7 MWd/kg-HM was achieved in this study. This optimum design uses a HM loading of 2.5 g/pebble with average axial fuel velocity 0.5 cm/day.

  2. In Vitro Studies and Preliminary Mathematical Model for Jet Fuel and Noise Induced Auditory Impairment

    Science.gov (United States)

    2015-06-01

    of JP-8 and a Fischer- Tropsch synthetic jet fuel following subacute inhalation exposure in rats. Toxicol Sci 116(1): 239-248. Gallinat, J...AFRL-RH-WP-TR-2015-0084 IN VITRO STUDIES AND PRELIMINARY MATHEMATICAL MODEL FOR JET FUEL AND NOISE INDUCED AUDITORY IMPAIRMENT...April 2014 – September 2014 4. TITLE AND SUBTITLE In Vitro Studies and Preliminary Mathematical Model for Jet Fuel and Noise Induced Auditory

  3. PRELIMINARY RESULTS OF THE COMPARISON OF SATELLITE IMAGERS USING TUZ GÖLÜ AS A REFERENCE STANDARD

    Directory of Open Access Journals (Sweden)

    H. Özen

    2012-07-01

    Full Text Available Earth surfaces, such as deserts, salt lakes, and playas, have been widely used in the vicarious radiometric calibration of optical earth observation satellites. In 2009, the Infrared and Visible Optical Sensors (IVOS sub-group of the Committee of Earth Observation Satellites (CEOS Working Group on Calibration and Validation (WGCV designated eight LANDNET reference sites to focus international efforts, facilitate traceability and enable the establishment of measurement "best practices." With support from the European Space Agency (ESA, one of the LANDNET sites, the Tuz Gölü salt lake located in central Turkey, was selected to host a cross-comparison of measurement instrumentation and methodologies conducted by 11 different ground teams across the globe. This paper provides an overview of the preliminary results of the cross-comparison of the ground-based spectral measurements made during the CEOS Land Comparison 13-27 August, 2010 with the simultaneous satellite image data acquisitions of the same site.

  4. Preliminary study of tumor heterogeneity in imaging predicts two year survival in pancreatic cancer patients.

    Directory of Open Access Journals (Sweden)

    Jayasree Chakraborty

    Full Text Available Pancreatic ductal adenocarcinoma (PDAC is one of the most lethal cancers in the United States with a five-year survival rate of 7.2% for all stages. Although surgical resection is the only curative treatment, currently we are unable to differentiate between resectable patients with occult metastatic disease from those with potentially curable disease. Identification of patients with poor prognosis via early classification would help in initial management including the use of neoadjuvant chemotherapy or radiation, or in the choice of postoperative adjuvant therapy. PDAC ranges in appearance from homogeneously isoattenuating masses to heterogeneously hypovascular tumors on CT images; hence, we hypothesize that heterogeneity reflects underlying differences at the histologic or genetic level and will therefore correlate with patient outcome. We quantify heterogeneity of PDAC with texture analysis to predict 2-year survival. Using fuzzy minimum-redundancy maximum-relevance feature selection and a naive Bayes classifier, the proposed features achieve an area under receiver operating characteristic curve (AUC of 0.90 and accuracy (Ac of 82.86% with the leave-one-image-out technique and an AUC of 0.80 and Ac of 75.0% with three-fold cross-validation. We conclude that texture analysis can be used to quantify heterogeneity in CT images to accurately predict 2-year survival in patients with pancreatic cancer. From these data, we infer differences in the biological evolution of pancreatic cancer subtypes measurable in imaging and identify opportunities for optimized patient selection for therapy.

  5. Preliminary study of tumor heterogeneity in imaging predicts two year survival in pancreatic cancer patients.

    Science.gov (United States)

    Chakraborty, Jayasree; Langdon-Embry, Liana; Cunanan, Kristen M; Escalon, Joanna G; Allen, Peter J; Lowery, Maeve A; O'Reilly, Eileen M; Gönen, Mithat; Do, Richard G; Simpson, Amber L

    2017-01-01

    Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal cancers in the United States with a five-year survival rate of 7.2% for all stages. Although surgical resection is the only curative treatment, currently we are unable to differentiate between resectable patients with occult metastatic disease from those with potentially curable disease. Identification of patients with poor prognosis via early classification would help in initial management including the use of neoadjuvant chemotherapy or radiation, or in the choice of postoperative adjuvant therapy. PDAC ranges in appearance from homogeneously isoattenuating masses to heterogeneously hypovascular tumors on CT images; hence, we hypothesize that heterogeneity reflects underlying differences at the histologic or genetic level and will therefore correlate with patient outcome. We quantify heterogeneity of PDAC with texture analysis to predict 2-year survival. Using fuzzy minimum-redundancy maximum-relevance feature selection and a naive Bayes classifier, the proposed features achieve an area under receiver operating characteristic curve (AUC) of 0.90 and accuracy (Ac) of 82.86% with the leave-one-image-out technique and an AUC of 0.80 and Ac of 75.0% with three-fold cross-validation. We conclude that texture analysis can be used to quantify heterogeneity in CT images to accurately predict 2-year survival in patients with pancreatic cancer. From these data, we infer differences in the biological evolution of pancreatic cancer subtypes measurable in imaging and identify opportunities for optimized patient selection for therapy.

  6. Energy dependent neutron imaging

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Hitterman, R.L.; Rhodes, E.

    1990-01-01

    A waste package consisting of a container and high-level nuclear waste is being developed for the permanent disposal of radioactive waste. Yucca Mountain, Nevada, is being studied as a potential site for the underground high-level nuclear waste repository. A major consideration for choosing Yucca Mountain is the presence of zeolite in tertiary ash-flow tuffs. The presence of zeolites could provide geological barriers to radionuclide migration. The suitability of the tuffaceous rocks at Yucca Mountain for the repository is being investigated since the properties of the environment around a waste site must be well characterized to reliably predict performance. The results of experiments at Lawrence Livermore National Laboratory (LLNL) to assess the possibility of imaging water in Nevada Test Site welded tuff samples showed that nuclear magnetic resonance imaging is not viable. This leaves neutron tomography and high-frequency electromagnetic geotomography as possibilities for the practical imaging of distribution and flow of fluids in rock, including tuff specimens. Water tracers are needed in electromagnetic tomography techniques since the contrast for detecting water in cracks of tuff is lower than in granite because of the higher porosity in tuff. The results of preliminary testing with geotomography by LLNL indicates relatively low spatial resolution. More sensitive techniques for detecting water is needed. This paper describes preliminary experiments to apply pulsed neutrons to image water in a sample of tuff. 3 refs., 3 figs

  7. Preliminary conceptual study of engineering-scale pyroprocess demonstration facility

    International Nuclear Information System (INIS)

    Moon, Seong-In; Chong, Won-Myung; You, Gil-Sung; Ku, Jeong-Hoe; Kim, Ho-Dong

    2013-01-01

    Highlights: ► The conceptual design of a pyroprocess demonstration facility was performed. ► The design requirements for the pyroprocess hot cell and equipment were determined. ► The maintenance concept for the pyroprocess hot cell was presented. -- Abstract: The development of an effective management technology of spent fuel is important to enhance environmental friendliness, cost viability and proliferation resistance. In Korea, pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems. PRIDE (PyRoprocess Integrated inactive DEmonstration facility) has been developed from 2007 to 2012 in Korea as a cold test facility to support integrated pyroprocessing and an equipment demonstration, which is essential to verify the pyroprocess technology. As the next stage of PRIDE, the design requirements of an engineering-scale demonstration facility are being developed, and the preliminary conceptual design of the facility is being performed for the future. In this paper, the main design requirements for the engineering-scale pyroprocess demonstration facility were studied in the throughput of 10tHM a year. For the preliminary conceptual design of the facility, the design basis of the pyroprocess hot cell was suggested, and the main equipment, main process area, operation area, maintenance area, and so on were arranged in consideration of the effective operation of the hot cells. Also, the argon system was designed to provide and maintain a proper inert environment for the pyroprocess. The preliminary conceptual design data will be used to review the validity of the engineering-scale pyroprocess demonstration facility that enhances both safety and nonproliferation

  8. In vivo detection of oral epithelial cancer using endogenous fluorescence lifetime imaging: a pilot human study (Conference Presentation)

    Science.gov (United States)

    Jo, Javier A.; Hwang, Dae Yon; Palma, Jorge; Cheng, Shuna; Cuenca, Rodrigo; Malik, Bilal; Jabbour, Joey; Cheng, Lisa; Wright, John; Maitland, Kristen

    2016-03-01

    Endogenous fluorescence lifetime imaging (FLIM) provides direct access to the concomitant functional and biochemical changes accompanying tissue transition from benign to precancerous and cancerous. Since FLIM can noninvasively measure different and complementary biomarkers of precancer and cancer, we hypothesize that it will aid in clinically detecting early oral epithelial cancer. Our group has recently demonstrated the detection of benign from premalignant and malignant lesions based on endogenous multispectral FLIM in the hamster cheek-pouch model. Encouraged by these positive preliminary results, we have developed a handheld endoscope capable of acquiring multispectral FLIM images in real time from the oral mucosa. This novel FLIM endoscope is being used for imaging clinically suspicious pre-malignant and malignant lesions from patients before undergoing tissue biopsy for histopathological diagnosis of oral epithelial cancer. Our preliminary results thus far are already suggesting the potential of endogenous FLIM for distinguishing a variety of benign lesions from advanced dysplasia and squamous cell carcinoma (SCC). To the best of out knowledge, this is the first in vivo human study aiming to demonstrate the ability to predict the true malignancy of clinically suspicious lesions using endogenous FLIM. If successful, the resulting clinical tool will allow noninvasive real-time detection of epithelial precancerous and cancerous lesions in the oral mucosa and could potentially be used to assist at every step involved on the clinical management of oral cancer patients, from early screening and diagnosis, to treatment and monitoring of recurrence.

  9. Corporate Social Disclosures in Southeast Asia: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Juniati Gunawan

    2012-12-01

    Full Text Available The issue of Corporate Social Disclosure (CSD has been growing remarkably both in business and academic world.  Inevitably, this topic is also exposed in Southeast Asia, a big region that plays important role in global economic issue. Applying a content analysis method, this paper aims to provide preliminary findings in CSD practices throughout the companies‟ annual reports in 2007 and 2008 for countries located in Southeast Asia.  Samples were selected for listed and unlisted various type of industries, based on the information availability internet searching. The sample collection and the subjectivity during the content analysis process are the limitations in conducting this study. In general, the results show that „human resources‟ are the main information disclosed, while in contrast, „energy‟ is the main least issue disclosed in the annual reports.  However, the findings need to be interpreted with considerations since there are limited in samples. Basically, the outcomes support the major prior studies and enhancing the discussion of CSD conducting in developing countries, while at the same time describing some countries which obtained very limited in exposures. To respond the vast increasing issues of CSD practice, this preliminary study has provided a basis to see the role of every country in CSR reporting and how they could support the sustainability development globally.

  10. A Preliminary study on the Biased Attention and Interpretation in the Recognition of Face-body Compound of the Individuals with Social Anxiety

    Directory of Open Access Journals (Sweden)

    Dong-Hyun eKim

    2016-03-01

    Full Text Available The present study aimed to investigate the processes through which individuals with social anxiety attend to and interpret compound emotional expressions of the face and body. Incongruent face-body compound images that combined an angry face (or body with a fearful, sad, or happy body (or face were presented to a social anxiety group (SA; n=22 and a healthy control group (HC; n=22. The participants were instructed to interpret the emotional state of the image, and their eye-movements and behavioral responses were measured. The results revealed that both group showed longer scanpath length during the recognition of compound images which combined angry face with angry, fearful, sadness, or happy body. The SA group also showed longer scanpath length in congruent face-body compound images of fear and sad. Additionally, the SA group fixated for a shorter period of time on the face and longer on the body than the HC group. Regarding emotion interpretation, the SA group was more likely to interpret the emotional state of incongruent face-body compound images based on the body than the HC group. These findings provide a preliminary observation that individuals with social anxiety showed different attentional bias pattern by congruency of face-body compound images and that it might have biased their interpretations of the emotional states.

  11. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin

    International Nuclear Information System (INIS)

    Jaimohan, S. M.; Naresh, M. D.; Arumugam, V.; Mandal, A. B.

    2009-01-01

    Parakeet (Psittacula krameri) haemoglobin has been purified and crystallized under low salt buffered conditions. Preliminary analysis of the crystal that belonged to monoclinic system (C2) is reported. Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemoglobins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 Å resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 Å, β = 109.35°. Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit

  12. 3D mutifractal analysis of cerebral tomoscintigraphy images

    International Nuclear Information System (INIS)

    Lopes, R.; Dubois, P.; Dewalle, A.S.; Betrouni, N.; Steinling, M.; Maouche, S.

    2007-01-01

    In this study, we describe the preliminary results of a tool to assist the diagnosis for the characterization of pathological cases of epilepsy disease using cerebral tomoscintigraphy images. The tool is based on the use of multifractal modelling to detect the local changes of homogeneity. (orig.)

  13. Preliminary In-Vivo Evaluation of Convex Array Synthetic Aperture Imaging

    DEFF Research Database (Denmark)

    Pedersen, Morten Høgholm; Gammelmark, Kim; Jensen, Jørgen Arendt

    2004-01-01

    of STA imaging in comparison to conventional imaging. The purpose is to evaluate whether STA imaging is feasible in-vivo. and whether the image quality obtained is comparable to traditional scanned imaging in terms of penetration depth, spatial resolution, contrast resolution, and artifacts. Acquisition...... was done using our RASMUS research scanner and a 5.5 MHz convex array transducer. STA imaging applies spherical wave emulation using multi-element subapertures and a 20 mus linear FM signal as excitation pulse. For conventional imaging a 64 element aperture was used in transmit and receive with a 1.5 cycle...

  14. Fire behaviour - A preliminary study. | W.S.W. | African Journal of ...

    African Journals Online (AJOL)

    Fire behaviour - A preliminary study. ... be taken cognisance of in any future research on fire in relation to vegetation. Keywords: behaviour; botany; environmental conditions; fire; fire behaviour; fire ecology; fires; grass; grasses; management; rate of spread; recovery; south africa; vegetation; veld; veld management; yield ...

  15. Biocontamination Control for Spacesuit Garments - A Preliminary Study

    Science.gov (United States)

    Rhodes, Richard A.; Orndoff, Evelyne; Korona, F. Adam; Poritz, Darwin; Smith, Jelanie; Wong, Wing

    2011-01-01

    This paper outlines a preliminary study that was conducted to review, test, and improve on current space suit biocontamination control. Biocontamination from crew members can cause space suit damage and objectionable odors and lead to crew member health hazards. An understanding of the level of biocontamination is necessary to mitigate its effects. A series of tests were conducted with the intent of evaluating current suit materials, ground and on-orbit disinfectants, and potential commercial off-the-shelf antimicrobial materials. Included in this paper is a discussion of the test methodology, results, and analysis method.

  16. Preliminary studies of 99mTc labeled fatty acid analogs for myocardial imaging

    International Nuclear Information System (INIS)

    Guo Yuzhi; Kung, H.F.; Mack, R.H.

    1988-01-01

    Radio iodine labelled fatty acid analogs are potential myocardial imaging agents for SPECT. In this paper are reported three new 99m Tc labbeled fatty acid analogs: 9 '9 m Tc-BAT-TDA, 99m Tc-BAT-PDA and 99m Tc-BAT-H x DA. Ligand exchange reaction with 99m Tc stannous glucoheptonate in 50% aqueous ethanol is used for labelling. The yield of reactions is 87%, 70%, 49% respectively. 99m Tc-fatty acid is purified by extraction into chloroform and the purity as determined by reverse phase HPLC is 98%. In order to determine the structure of Tc-BAT-fatty acid, 99 Tc-BAT-PDA is synthesized with 99 Tc ammonium pertechnetate in 50% citric acid buffer (pH=6)/ethanol using stannous chloride as the reducing agent. 99 Tc-BAT-PDA displays the expected Tc=O UV absorption at 420nm and strong peak at 900cm -1 in the FTIR spectrum. Biodistribution studies of three 99m Tc-fatty acid analogs are conducted in rats using 125 I-ω- (p-iodophenyl) -penta-decanoic acid (IPPDA) as internal standard. The initial heart uptake of them is significantly lower than that of 125 I-IPPDA

  17. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    emission tomography (PET) only, dedicated MR, regional positron emission tomography (PET) only and regional PET/Gd-MRI, respectively. There was no distant metastasis based on analysis of whole-body positron emission tomography (PET) and whole-body PET/Dixon-volume interpolated breathhold examination (VIBE) MRI. Regional PET/Gd-MRI combined with whole-body PET/MRI modified staging in three patients. Lesions of primary tumor and suspicious metastasis were well detected on both value of SUVmax and visual analysis. The regional PET/Gd-MRI combined with whole-body PET/MRI showed convenient clinical staging performance compared with positron emission tomography (PET) and MRI alone. In this preliminary study, PET attenuated by MRI showed good image quality to detect lesions. And whole-body PET/MRI as a single modality was feasible for staging in a clinical setting. Whole-body positron emission tomography (PET), regional positron emission tomography (PET), dedicated MRI and regional PET/Gd-MRI showed discordant results in lesion detection. These discordant results might be synergistic effect for accurate staging

  18. Decreased gray matter volume of the medial orbitofrontal cortex in panic disorder with agoraphobia: a preliminary study.

    Science.gov (United States)

    Na, Kyoung-Sae; Ham, Byung-Joo; Lee, Min-Soo; Kim, Leen; Kim, Yong-Ku; Lee, Heon-Jeong; Yoon, Ho-Kyoung

    2013-08-01

    Patients with panic disorder with agoraphobia (PDA) have clinical symptoms such as the fear of being outside or of open spaces from which escape would be difficult. Although recent neurobiological studies have suggested that fear conditioning and extinction are associated with PDA, no study has examined the possible structural abnormalities in patients with PDA. This preliminary study compares the gray matter volume among patients with PDA, those with panic disorder without agoraphobia (PDW), and healthy controls (HC) using high-resolution 3.0 T magnetic resonance imaging (MRI) with voxel-based morphometry (VBM). Compared with HC, patients with PDA showed decreased gray matter volume in their left medial orbitofrontal gyrus. However, differences were not found in the gray matter volumes of patients with PDW and whole panic disorder compared with HC. These findings suggest that the phobic avoidance found in patients with PDA arise from abnormalities in the medial orbitofrontal cortex, which plays an important role in fear extinction. Future studies should investigate the neuroanatomical substrates of PDA and distinguish them from those of PDW. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. A mobile app for securely capturing and transferring clinical images to the electronic health record: description and preliminary usability study.

    Science.gov (United States)

    Landman, Adam; Emani, Srinivas; Carlile, Narath; Rosenthal, David I; Semakov, Simon; Pallin, Daniel J; Poon, Eric G

    2015-01-02

    Photographs are important tools to record, track, and communicate clinical findings. Mobile devices with high-resolution cameras are now ubiquitous, giving clinicians the opportunity to capture and share images from the bedside. However, secure and efficient ways to manage and share digital images are lacking. The aim of this study is to describe the implementation of a secure application for capturing and storing clinical images in the electronic health record (EHR), and to describe initial user experiences. We developed CliniCam, a secure Apple iOS (iPhone, iPad) application that allows for user authentication, patient selection, image capture, image annotation, and storage of images as a Portable Document Format (PDF) file in the EHR. We leveraged our organization's enterprise service-oriented architecture to transmit the image file from CliniCam to our enterprise clinical data repository. There is no permanent storage of protected health information on the mobile device. CliniCam also required connection to our organization's secure WiFi network. Resident physicians from emergency medicine, internal medicine, and dermatology used CliniCam in clinical practice for one month. They were then asked to complete a survey on their experience. We analyzed the survey results using descriptive statistics. Twenty-eight physicians participated and 19/28 (68%) completed the survey. Of the respondents who used CliniCam, 89% found it useful or very useful for clinical practice and easy to use, and wanted to continue using the app. Respondents provided constructive feedback on location of the photos in the EHR, preferring to have photos embedded in (or linked to) clinical notes instead of storing them as separate PDFs within the EHR. Some users experienced difficulty with WiFi connectivity which was addressed by enhancing CliniCam to check for connectivity on launch. CliniCam was implemented successfully and found to be easy to use and useful for clinical practice. CliniCam is

  20. Preliminary nuclear decommissioning cost study

    International Nuclear Information System (INIS)

    Sissingh, R.A.P.

    1981-04-01

    The decommissioning of a nuclear power plant may involve one or more of three possible options: storage with surveillance (SWS), restricted site release (RSR), and unrestricted site use(USU). This preliminary study concentrates on the logistical, technical and cost aspects of decommissioning a multi-unit CANDU generating station using Pickering GS as the reference design. The procedure chosen for evaluation is: i) removal of the fuel and heavy water followed by decontamination prior to placing the station in SWS for thiry years; ii) complete dismantlement to achieve a USU state. The combination of SWS and USU with an interim period of surveillance allows for radioactive decay and hence less occupational exposure in achieving USU. The study excludes the conventional side of the station, assumes waste disposal repositories are available 1600 km away from the station, and uses only presently available technologies. The dismantlement of all systems except the reactor core can be accomplished using Ontario Hydro's current operating, maintenance and construction procedures. The total decommissioning period is spread out over approximately 40 years, with major activities concentrated in the first and last five years. The estimated dose would be approximately 1800 rem. Overall Pickering GS A costs would be $162,000,000 (1980 Canadian dollars)

  1. PET/MRI: a novel hybrid imaging technique: major clinical indications and preliminary experience in Brazil; PET/RM: um novo metodo de imagem hibrida: principais indicacoes clinicas e experiencia preliminar no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Vitor, Taise; Martins, Karine Minaif; Ionescu, Tudor Mihai and others, E-mail: taisevitor@gmail.com [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)

    2017-04-01

    In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/ CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. (author)

  2. Swimsuit issues: promoting positive body image in young women's magazines.

    Science.gov (United States)

    Boyd, Elizabeth Reid; Moncrieff-Boyd, Jessica

    2011-08-01

    This preliminary study reviews the promotion of healthy body image to young Australian women, following the 2009 introduction of the voluntary Industry Code of Conduct on Body Image. The Code includes using diverse sized models in magazines. A qualitative content analysis of the 2010 annual 'swimsuit issues' was conducted on 10 Australian young women's magazines. Pictorial and/or textual editorial evidence of promoting diverse body shapes and sizes was regarded as indicative of the magazines' upholding aspects of the voluntary Code of Conduct for Body Image. Diverse sized models were incorporated in four of the seven magazines with swimsuit features sampled. Body size differentials were presented as part of the swimsuit features in three of the magazines sampled. Tips for diverse body type enhancement were included in four of the magazines. All magazines met at least one criterion. One magazine displayed evidence of all three criteria. Preliminary examination suggests that more than half of young women's magazines are upholding elements of the voluntary Code of Conduct for Body Image, through representation of diverse-sized women in their swimsuit issues.

  3. Preliminary study of flotation behavior of Besham Lead-Zinc ore

    International Nuclear Information System (INIS)

    Khan, M.M.; Din, F.; Rafiq, M.

    2001-01-01

    This preliminary study examines the flotation behavior of the mineral galena from Besham Lead-Zinc ore samples with reference to the particle size, collector types such as Ethyl and Propyl xanthates and depressants. The comminution of the as mined ore was carried out in the laboratory jaw crusher and disc mill as well as in a laboratory ball mill. The material having size range between-90 microns and +63 microns was selected for flotation studies. (author)

  4. Paediatric x-ray radiation dose reduction and image quality analysis.

    Science.gov (United States)

    Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H

    2013-09-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.

  5. Paediatric x-ray radiation dose reduction and image quality analysis

    International Nuclear Information System (INIS)

    Martin, L; Ruddlesden, R; Mistry, T; Starritt, H; Makepeace, C; Robinson, L

    2013-01-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%–55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children. (paper)

  6. Demonstration of the blood-ocular barrier integrity by contrast-enhanced MR imaging: A preliminary study

    International Nuclear Information System (INIS)

    Frank, J.A.; Dwyer, A.J.; Girton, M.; Sank, V.; Knop, R.H.; Gansow, O.A.; Brechbiel, M.W.; Doppman, J.L.

    1986-01-01

    In five Rhesus monkeys we assessed the potential for monitoring the blood-ocular barrier (BOB) with Gd-DTPA-enhanced MR imaging. Unilateral opening of the BOB was achieved by infusion of mannitol into the internal carotid artery. This was followed immediately by Gd-DTPA, 0.2 mmol/kg, given intravenously. T-l weighted MR images (Picken unit, 0.5 T, SE 500/40, 5-mm thickness, 15cm FOV) obtained before and within one-half hour after injection of Gd-DTPA demonstrated marked enhancement (2-to 17-fold) of the anterior and posterior chambers of the challenged eye, representing leakage of Gd-DTPA into those chambers. Animals remained free of ocular side effects

  7. Synthesis and preliminary biological evaluation of new radioiodinated MMP inhibitors for imaging MMP activity in vivo

    International Nuclear Information System (INIS)

    Kopka, Klaus; Breyholz, Hans-Joerg; Wagner, Stefan; Law, Marilyn P.; Riemann, Burkhard; Schroeer, Sandra; Trub, Monika; Guilbert, Benedicte; Levkau, Bodo; Schober, Otmar; Schaefers, Michael

    2004-01-01

    Non-invasive measurement of matrix metalloproteinase (MMP) activity in vivo is a clinical challenge in many disease processes such as inflammation, tumor metastasis and atherosclerosis. Therefore, radioiodinated analogues of the non-peptidyl broad-spectrum MMP inhibitor (MMPI) CGS 27023A 1a were synthesized for non-invasive detection of MMP activity in vivo using single photon emission computed tomography (SPECT). The compounds Br-CGS 27023A 1b and HO-CGS 27023A 1d were synthesized from the amino acid D-valine and used as precursors for radioiodinated derivatives of CGS 27023A and their non-radioactive references I-CGS 27023A 1c and HO-I-CGS 27023A 1e. Radioiodination of the precursors with [ 123 I]NaI or [ 125 I]NaI produced the no-carrier-added MMP inhibitors [ 123 I]I-CGS 27023A 1f, [ 125 I]I-CGS 27023A 1g, HO-[ 123 I]I-CGS27023A 1h, and HO-[ 125 I]I-CGS 27023A 1i. In vitro studies showed that the non-radioactive analogues of the MMP inhibitors exhibited affinities against gelatinase A (MMP-2) and gelatinase B (MMP-9) in the nanomolar range, comparable to the parent compound CGS 27023A. In vivo biodistribution using HO-[ 125 I]I-CGS 27023A 1i in CL57 Bl6 mice showed rapid blood and plasma clearance and low retention in normal tissues. The preliminary biological evaluation warrant further studies of these radioiodinated MMP inhibitors as potential new radiotracers for imaging MMP activity in vivo

  8. Presentation of preliminary studies relative to the long duration disposal of medium level and long lived (MLLL) wastes

    International Nuclear Information System (INIS)

    Leroy, C.; Moreau, A.; Fayette, L.; Bellon, M.; Templier, J.C.; Macias, R.M.; Porcher, J.B.; Rey, F.; Hollender, F.; Girard, J.P.

    2002-01-01

    In the contract of objectives signed in 2001 with the government, the French atomic energy commission (CEA) committed itself to supply reports of preliminary studies about long duration disposal concepts for medium level and long lived radioactive wastes. This document makes the synthesis of the preliminary studies carried out in 2001 and 2002 by exploring simultaneously the surface and subsurface disposal concepts. The studies deal with the design of a facility with a long service life. Four hypotheses have been retained for the preliminary studies: a secular lifetime (typically 100 to 300 years), a single and new site for all waste packages (no existing facility available), two confinement barriers, an envelope-type site with specific characteristics (seismicity, climate conditions, airplane crash..). These preliminary studies show the existence of solutions for each option: with and without storage containers in both type (surface and subsurface) of facilities. They outline the necessity of studying more thoroughly some technical points. This instruction will be performed for the concepts retained after a multi-criteria analysis. (J.S.)

  9. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Best (Netherlands); Bastian, Patrick J. [University of Munich, Department of Urology, Munich (Germany); Schmitz, Bettina; Mueller, Stefan C. [University of Bonn, Department of Urology, Bonn (Germany)

    2008-11-15

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests

  10. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H.; Gieseke, Juergen; Bastian, Patrick J.; Schmitz, Bettina; Mueller, Stefan C.

    2008-01-01

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests. Dynamic

  11. Preliminary study of internal wave effects to chlorophyll distribution in the Lombok Strait and adjacent areas

    Science.gov (United States)

    Arvelyna, Yessy; Oshima, Masaki

    2005-01-01

    This paper studies the effect of internal wave in the Lombok Strait to chlorophyll distribution in the surrounded areas using ERS SAR, ASTER, SeaWiFS and AVHRR-NOAA images data during 1996-2004 periods. The observation results shows that the internal waves were propagated to the south and the north of strait and mostly occurred during transitional season from dry to wet and wet season (rainy season) between September to December when the layers are strongly stratified. Wavelet transform of image using Meyer wavelet analysis is applied for internal wave detection in ERS SAR and ASTER images, for symmetric extension of data at the image boundaries, to prevent discontinuities by a periodic wrapping of data in fast algorithm and space-saving code. Internal wave created elongated pattern in detail and approximation of image from level 2 to 5 and retained value between 2-4.59 times compared to sea surface, provided accuracy in classification over than 80%. In segmentation process, the Canny edge detector is applied on the approximation image at level two to derive internal wave signature in image. The proposed method can extract the internal wave signature, maintain the continuity of crest line while reduce small strikes from noise. The segmentation result, i.e. the length between crest and trough, is used to compute the internal wave induced current using Korteweg-de Vries (KdV) equation. On ERS SAR data contains surface signature of internal wave (2001/8/20), we calculated that internal wave propagation speed was 1.2 m/s and internal wave induced current was 0.56 m/s, respectively. From the observation of ERS SAR and SeaWiFS images data, we found out that the distribution of maximum chlorophyll area at southern coastline off Bali Island when strong internal wave induced current occurred in south of the Lombok Strait was distributed further to westward, i.e. from 9.25°-10.25°LS, 115°-116.25°SE to 8.8°-10.7°LS, 114.5°-116°SE, and surface chlorophyll concentration

  12. MR imaging of skeletal soft tissue infection: utility of diffusion-weighted imaging in detecting abscess formation

    International Nuclear Information System (INIS)

    Harish, Srinivasan; Rebello, Ryan; Chiavaras, Mary M.; Kotnis, Nikhil

    2011-01-01

    Our objectives were to assess if diffusion-weighted imaging (DWI) can help identify abscess formation in the setting of soft tissue infection and to assess whether abscess formation can be diagnosed confidently with a combination of DWI and other unenhanced sequences. Eight cases of soft tissue infection imaged with MRI including DWI were retrospectively reviewed. Two male and six female patients were studied (age range 23-50 years). Unenhanced MRI including DWI was performed in all patients. Post-contrast images were obtained in seven patients. All patients had clinically or surgically confirmed abscesses. Abscesses demonstrated restricted diffusion. DWI in conjunction with other unenhanced imaging showed similar confidence levels as post-contrast images in diagnosing abscess formation in four cases. In two cases, although the combined use of DWI and other unenhanced imaging yielded the same confidence levels as post-contrast imaging, DWI was more definitive for demonstrating abscess formation. In one case, post-contrast images had a better confidence for suggesting abscess. In one case, DWI helped detected the abscess, where gadolinium could not be administered because of a contraindication. This preliminary study suggests that DWI is a useful adjunct in the diagnosis of skeletal soft tissue abscesses. (orig.)

  13. Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Cen [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); First Affiliated Hospital of Soochow University, Department of Radiology, Suzhou (China); Zhang, Huan; Du, Lianjun; Pan, Zilai; Yan, Fuhua [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Yan, Jing [Siemens Medical System, Shanghai (China); Wang, Baisong [Shanghai Jiao Tong University School of Medicine, Department of Biological Statistics, Shanghai (China)

    2017-02-15

    To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). 31 EGC patients (19 men, 12 women; age range, 38-81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated. AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC. (orig.)

  14. Brown Adipose Tissue Can Be Activated or Inhibited within an Hour before 18F-FDG Injection: A Preliminary Study with MicroPET

    Directory of Open Access Journals (Sweden)

    Chenxi Wu

    2011-01-01

    Full Text Available Brown adipose tissue (BAT is emerging as a potential target for treating human obesity. It has been indicated that BAT is rich in innervations of sympathetic nerve control. Using 18F-FDG microPET imaging, this study aims at evaluating how factors related to sympathetic activation/inhibition changed BAT metabolism of mice. BAT 18F-FDG uptake were semiquantitatively evaluated in different groups of mice under temperature (cold or warm stimulus or pharmacological interventions (norepinephrine, epinephrine, isoprenaline, or propranolol and were compared with the corresponding controls. It was found that BAT activation can be stimulated by cold exposure (P=1.96×10−4, norepinephrine (P=.002, or both (P=2.19×10−6 within an hour before 18F-FDG injection and can also be alleviated by warming up (P=.001 or propranolol lavage (P=.027. This preliminary study indicated that BAT function could be evaluated by 18F-FDG PET imaging through short-term interventions, which paved the way for further investigation of the relationship between human obesity and BAT dysfunction.

  15. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  16. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  17. Studies of scintillator response to 60 MeV protons in a proton beam imaging system

    Directory of Open Access Journals (Sweden)

    Rydygier Marzena

    2015-09-01

    Full Text Available A Proton Beam Imaging System (ProBImS is under development at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN. The ProBImS will be used to optimize beam delivery at IFJ PAN proton therapy facilities, delivering two-dimensional distributions of beam profiles. The system consists of a scintillator, optical tract and a sensitive CCD camera which digitally records the light emitted from the proton-irradiated scintillator. The optical system, imaging data transfer and control software have already been developed. Here, we report preliminary results of an evaluation of the DuPont Hi-speed thick back screen EJ 000128 scintillator to determine its applicability in our imaging system. In order to optimize the light conversion with respect to the dose locally deposited by the proton beam in the scintillation detector, we have studied the response of the DuPont scintillator in terms of linearity of dose response, uniformity of light emission and decay rate of background light after deposition of a high dose in the scintillator. We found a linear dependence of scintillator light output vs. beam intensity by showing the intensity of the recorded images to be proportional to the dose deposited in the scintillator volume.

  18. Nevada potential repository preliminary transportation strategy Study 2. Volume 1

    International Nuclear Information System (INIS)

    1996-02-01

    The objectives of this study were to build on the findings of the Nevada Potential Repository Preliminary Transportation Strategy Study 1 (CRWMS M ampersand O 1995b), and to provide additional information for input to the repository environmental impact statement (EIS) process. In addition, this study supported the future selection of a preferred rail corridor and/or heavy haul route based on defensible data, methods, and analyses. Study research did not consider proposed legislation. Planning was conducted according to the Civilian Radioactive Waste Management Program Plan (DOE 1994a). The specific objectives of Study 2 were to: eliminate or reduce data gaps, inconsistencies, and uncertainties, and strengthen the analysis performed in Study 1; develop a preliminary list of rail route evaluation criteria that could be used to solicit input from stakeholders during scoping meetings. The evaluation criteria will be revised based on comments received during scoping; restrict and refine the width of the four rail corridors identified in Study 1 to five miles or less, based on land use constraints and engineering criteria identified and established in Study 2; evaluate national-level effects of routing spent nuclear fuel and high-level waste to the four identified branch lines, including the effects of routing through or avoiding Las Vegas; continue to gather published land use information and environmental data to support the repository EIS; continue to evaluate heavy haul truck transport over three existing routes as an alternative to rail and provide sufficient information to support the repository EIS process; and evaluate secondary uses for rail (passenger use, repository construction, shared use)

  19. Preliminary studies in rice-fish culture in a rainfed lowland ecology ...

    African Journals Online (AJOL)

    Mixed farms of rice and fish are yet to receive attention in Ghana, despite lowland rice being grown under inundation in most areas nationwide. In a preliminary study, Nile tilapia (Oreochromis niloticus) was successfully cultured in a rainfed lowland rice farm, although no additional care was provided for fishes. The highest ...

  20. Small hydropower station in Lavin - Preliminary study

    International Nuclear Information System (INIS)

    Merz, F.

    2008-05-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) presents the results of a preliminary study regarding a proposed small hydropower installation on the alpine river Lavinuoz in Lavin, Switzerland. The geographical situation with mountains and glaciers in the catchment area of the proposed hydropower installation is discussed as are the appropriate water catchment installations. Possible dangers caused by avalanches and rock fall are examined. The power to be produced - 5,500,000 kWh/y - by the turbine which is nominally rated at 1350 kW is discussed, as are estimates of production costs. Figures on the investments required and the economic feasibility of the project are discussed, as are environmental factors that are to be taken into account.

  1. Preliminary design study of the TMT Telescope structure system: overview

    Science.gov (United States)

    Usuda, Tomonori; Ezaki, Yutaka; Kawaguchi, Noboru; Nagae, Kazuhiro; Kato, Atsushi; Takaki, Junji; Hirano, Masaki; Hattori, Tomoya; Tabata, Masaki; Horiuchi, Yasushi; Saruta, Yusuke; Sofuku, Satoru; Itoh, Noboru; Oshima, Takeharu; Takanezawa, Takashi; Endo, Makoto; Inatani, Junji; Iye, Masanori; Sadjadpour, Amir; Sirota, Mark; Roberts, Scott; Stepp, Larry

    2014-07-01

    We present an overview of the preliminary design of the Telescope Structure System (STR) of Thirty Meter Telescope (TMT). NAOJ was given responsibility for the TMT STR in early 2012 and engaged Mitsubishi Electric Corporation (MELCO) to take over the preliminary design work. MELCO performed a comprehensive preliminary design study in 2012 and 2013 and the design successfully passed its Preliminary Design Review (PDR) in November 2013 and April 2014. Design optimizations were pursued to better meet the design requirements and improvements were made in the designs of many of the telescope subsystems as follows: 1. 6-legged Top End configuration to support secondary mirror (M2) in order to reduce deformation of the Top End and to keep the same 4% blockage of the full aperture as the previous STR design. 2. "Double Lower Tube" of the elevation (EL) structure to reduce the required stroke of the primary mirror (M1) actuators to compensate the primary mirror cell (M1 Cell) deformation caused during the EL angle change in accordance with the requirements. 3. M1 Segment Handling System (SHS) to be able to make removing and installing 10 Mirror Segment Assemblies per day safely and with ease over M1 area where access of personnel is extremely difficult. This requires semi-automatic sequence operation and a robotic Segment Lifting Fixture (SLF) designed based on the Compliance Control System, developed for controlling industrial robots, with a mechanism to enable precise control within the six degrees of freedom of position control. 4. CO2 snow cleaning system to clean M1 every few weeks that is similar to the mechanical system that has been used at Subaru Telescope. 5. Seismic isolation and restraint systems with respect to safety; the maximum acceleration allowed for M1, M2, tertiary mirror (M3), LGSF, and science instruments in 1,000 year return period earthquakes are defined in the requirements. The Seismic requirements apply to any EL angle, regardless of the

  2. Study on folate receptor PET imaging agent 18F-flurophenethyl folate

    International Nuclear Information System (INIS)

    Guo Congying; Zhu Jianhua; Qian Jun; Yang Yang; Shen Haixing; Zhang Zhengwei

    2009-01-01

    This work is aimed at synthesizing an 18 F-labelled folate derivative that can be used as folate-receptor induced tumor PET imaging agent. Under the optimal reaction and testing specification formulated during the cold-labeling experiments, 18 F labeling of folic acid was achieved in three steps of 18 F pre-labeling,bromination and esterification. The receptor binding property of the newly-synthesized folate radio-derivative was studied through β-lactoglobulin binding test. Tumor-bearing nude mice injected with the new compound were used to study whether the derivative can accumulate within tumor issue. Preliminary studies in vitro and in vivo showed that this new PET agent still possessed receptor binding qualities of folic acid. 18 F-flurophenethyl folate remained good affinity and specificity with β-lactoglobulin. Accumulation of activities in tumor tissues was found in tumor-bearing nude mice. A new folate receptor ligand: 18 F-flurophenethyl folate was synthesized,with high yield and good stability. Since the pre-labeling method was used, the fluorine labeling was not directly imposed upon folic acid.In this way, the structure destruction, which happens in high temperature reaction of folic acid, can be avoided. The synthesized folate derivative remained the binding structural quality of folic acid and could bind with the folate-binding protein: β-lactoglobulin. Through the folate receptors located on tumor tissues, 18 F-flurophenethyl folate accumulated in the tumor tissue, exhibiting its potential as a tumor PET imaging agent. (authors)

  3. Preliminary study on development of 300 Kv compact focused gaseous ion beam system

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, T.; Ishii, Y.; Kamiya, T. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA) 1233 Watanuki-machi, Takasaki, Gunma, 370-1292 (Japan); Miyake, Y. [Beam Seiko Instruments Inc., 2-10-1 Kamata, Ohta-ku, Tokyo, 144-0052 (Japan)

    2013-04-19

    A new 300 kV compact focused gaseous ion beam (gas-FIB) system with three-stage acceleration lens was constructed at JAEA. The preliminary experiments of formation of the focused gaseous ion beams were carried out to show the availability of the gas-FIB system as a writing tool for 3D proton lithography. As a result of the experiments, it was proved that the focal point was kept at the same position under changing the kinetic energy but with keeping the kinetic energy ratio constant, which was defined as the ratio of kinetic energy in object side to that in image side for the third acceleration lens. This characteristic of the gas-FIB is a good point to advance the 3D proton lithography changing penetration depth in a sample by varying the beam energy.

  4. Preliminary study on development of 300 Kv compact focused gaseous ion beam system

    International Nuclear Information System (INIS)

    Ohkubo, T.; Ishii, Y.; Kamiya, T.; Miyake, Y.

    2013-01-01

    A new 300 kV compact focused gaseous ion beam (gas-FIB) system with three-stage acceleration lens was constructed at JAEA. The preliminary experiments of formation of the focused gaseous ion beams were carried out to show the availability of the gas-FIB system as a writing tool for 3D proton lithography. As a result of the experiments, it was proved that the focal point was kept at the same position under changing the kinetic energy but with keeping the kinetic energy ratio constant, which was defined as the ratio of kinetic energy in object side to that in image side for the third acceleration lens. This characteristic of the gas-FIB is a good point to advance the 3D proton lithography changing penetration depth in a sample by varying the beam energy.

  5. Study for a novel tomography technique using an imaging plate

    CERN Document Server

    Kobayashi, H; Matsubayashi, M

    1999-01-01

    A sinogram is directly recorded onto an imaging plate for neutron tomography, which has excellent capability to detect neutrons. A sinogram-recording-system and outline of the data processing are explained briefly. A tomogram of a test object is reconstructed and shown as the preliminary result. The linearity of CT values was experimentally confirmed up to 1.6 cm sup - sup 1 of effective total macroscopic cross section, but about 10% lower CT value was observed at 2.7 cm sup - sup 1. The linearity limitation and statistical character of CT values are discussed with regard to the dynamic range of the system as well as the effect of background components.

  6. Ultrasound imaging with a micromotor; Micromotor ni yoru choonpa imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, O.; Salimuzzaman, M.; Matani, A.; Chihara, K. [Nara Institute of Science and Technology, Nara (Japan); Asao, M. [Osaka National Hospital, Osaka (Japan)

    1998-03-01

    This paper describes a new ultrasound intravascular imaging system. In this system, an ultrasound probe consists of a micromotor, an ultrasound reflecting mirror attached with the micromotor and an ultrasound transducer. Ultrasound is scanned radially by a micromotor instead of a rotation transmitting wire and the rotation of the micromotor is performed and controlled by an external magnetic field. This ultrasound imaging system with a micromotor was applied to observe the inside of blood vessels through in vitro experiments. The preliminary results suggest that this system has the sufficient ability to define the blood vessel morphology and that the simple image processing enhances signal-to-noise ratio of the reconstructed image. 12 refs., 5 figs.

  7. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  8. Identification of early cancerous lesion of esophagus with endoscopic images by hyperspectral image technique (Conference Presentation)

    Science.gov (United States)

    Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen

    2016-03-01

    This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.

  9. Preliminary rail access study

    International Nuclear Information System (INIS)

    1990-01-01

    The Yucca Mountain site, located on the southwestern edge of the Nevada Test Site, is an undeveloped area under investigation as a potential site for nuclear waste disposal by the US Department of Energy. The site currently lacks rail service and an existing rail right-of-way. If the site is suitable and selected for development as a disposal site, rail service is desirable to the Office of Civilian Radioactive Waste Management Program because of the potential of rail to reduce number of shipments and costs relative to highway transportation. This preliminary report is a summary of progress to date for activities to identify and evaluate potential rail options from major rail carriers in the region to the Yucca Mountain site. It is currently anticipated that the rail spur will be operational after the year 2000. 9 refs., 13 figs., 2 tabs

  10. Brain connectivity study of brain tumor patients using MR-PET data: preliminary results

    International Nuclear Information System (INIS)

    Mendes, Ana Carina; Ribeiro, Andre Santos; Oros-Peusquens, Ana Maria; Langen, Karl Josef; Shah, Jon; Ferreira, Hugo Alexandre

    2015-01-01

    Brain activity results from anatomical and functional connections that can be disrupted or altered due to trauma or lesion. This work presents a first approach on the study of whole-brain connectivity of brain tumor patients using the Multimodal Imaging Brain Connectivity (MIBCA) toolbox. Two patients with glioblastoma lesions located in the left hemisphere (one in the motor cortex and the other in the temporal lobe) underwent simultaneous MRI and dynamic PET scans using a 3T MRI scanner with a BrainPET insert. The following data was acquired: T1-w MPRAGE (1x1x1mm 3 ), DTI (dir=30, b=0,800s/mm2, 2x2x2mm 3 ), and dynamic 18F-FET PET. The MIBCA toolbox was used to automatically pre-process MRI-PET data and to derive imaging and connectivity metrics from the multimodal data. Computed metrics included: cortical thickness from T1-w data; mean diffusivity (MD), fractional anisotropy (FA), node degree, clustering coefficient and pairwise ROI fibre tracking (structural connectivity) from DTI data; and standardized uptake value (SUV) from PET data. For all the metrics, the differences between left and right hemispherical structures were obtained, followed by a 25% threshold (except for SUV thresholded at 15%). Data was visualized in a connectogram, and both structural connectivity and metrics were studied in regions surrounding lesions. Preliminary results showed increased SUV values in regions surrounding the tumor for both patients. Patients also showed changes in structural connectivity involving these regions and also other more spatially distant regions such as the putamen and the pallidum, including decreased number of fibers between the subcortical structures themselves and with frontal regions. These findings suggest that the presence of a tumor may alter both local and more distant structural connections. Presently, a larger patient sample is being studied along with the inclusion of a control group to test the consistency of the findings.

  11. Brain connectivity study of brain tumor patients using MR-PET data: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Ana Carina [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal); Ribeiro, Andre Santos [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal); Centre for Neuropsychopharmacology, Division of Brain Sciences, Department of Medicine, Imperial College London, London (United Kingdom); Oros-Peusquens, Ana Maria; Langen, Karl Josef; Shah, Jon [Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich (Germany); Ferreira, Hugo Alexandre [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal)

    2015-05-18

    Brain activity results from anatomical and functional connections that can be disrupted or altered due to trauma or lesion. This work presents a first approach on the study of whole-brain connectivity of brain tumor patients using the Multimodal Imaging Brain Connectivity (MIBCA) toolbox. Two patients with glioblastoma lesions located in the left hemisphere (one in the motor cortex and the other in the temporal lobe) underwent simultaneous MRI and dynamic PET scans using a 3T MRI scanner with a BrainPET insert. The following data was acquired: T1-w MPRAGE (1x1x1mm{sup 3}), DTI (dir=30, b=0,800s/mm2, 2x2x2mm{sup 3}), and dynamic 18F-FET PET. The MIBCA toolbox was used to automatically pre-process MRI-PET data and to derive imaging and connectivity metrics from the multimodal data. Computed metrics included: cortical thickness from T1-w data; mean diffusivity (MD), fractional anisotropy (FA), node degree, clustering coefficient and pairwise ROI fibre tracking (structural connectivity) from DTI data; and standardized uptake value (SUV) from PET data. For all the metrics, the differences between left and right hemispherical structures were obtained, followed by a 25% threshold (except for SUV thresholded at 15%). Data was visualized in a connectogram, and both structural connectivity and metrics were studied in regions surrounding lesions. Preliminary results showed increased SUV values in regions surrounding the tumor for both patients. Patients also showed changes in structural connectivity involving these regions and also other more spatially distant regions such as the putamen and the pallidum, including decreased number of fibers between the subcortical structures themselves and with frontal regions. These findings suggest that the presence of a tumor may alter both local and more distant structural connections. Presently, a larger patient sample is being studied along with the inclusion of a control group to test the consistency of the findings.

  12. An MRI system for imaging neonates in the NICU: initial feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A. [Perinatal Institute, Cincinnati Children' s Hospital Medical Center, Division of Neonatology and Pulmonary Biology, Cincinnati, OH (United States); Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2012-11-15

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  13. An MRI system for imaging neonates in the NICU: initial feasibility study

    International Nuclear Information System (INIS)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L.; Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A.; Kline-Fath, Beth M.

    2012-01-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  14. An MRI system for imaging neonates in the NICU: initial feasibility study.

    Science.gov (United States)

    Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L

    2012-11-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.

  15. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  16. Preliminary study of spectral CT imaging in the differential diagnosis of metastatic lymphadenopathy due to various tumors

    International Nuclear Information System (INIS)

    Liu Jingang; Liu Ya; Li Lixin

    2011-01-01

    Objective: To investigate the feasibility of differentiating lymph node metastases of four types of primary tumors (lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma) using gemstone spectral imaging (GSI). Methods: Three cases with lymphoma (28 lymph node), five cases with lung adenocarcinoma (30 lymph node), four cases with lung squamous cell carcinoma (24 lymph node) and two cases with cholangiocarcinoma (10 lymph node) were evaluated by germstona spectra imaging CT scans. Imaging protocol included unenhanced conventional CT scan (120 kVp), enhanced GSI (80/140 kVp) on arterial phase and conventional CT scan (120 kVp) on portal phase. CT attenuation values of lymph nodes in the monochromatic images at Il sets of keV levels (40- 140 keV, 10 keV step) and the iodine and water contents of these lymph nodes were measured. All results were analyzed with ANOVA and t test. Results: The optimal monochromatic level was 70 keV for the optimal contrast-noise ratio (CNR) of metastatic lymphadenopathy. The CT attenuation values of metastatic lymphadenopathy were (81.36±9.81), (58.33±21.55), (56.47±10.62) and (73.57±4.43) HU, respectively, at 70 keV (F=17.29, P 0.05). The iodine contents of lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma were (1.93±0.04), (1.16±0.15), (1.25±0.21) and (1.44±0.04) g/L, respectively. The water contents of lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma were (1029.40±20.85), (1024.98±11.19), (1022.12±12.94) and (1030.87±10.10) g/L, respectively. Except between lung squamous cell carcinoma and lung adenocarcinoma, the differences in the iodine contents of metastatic lymphadenopathy were significant among tumors (P 0.05 ). Conclusions: Although CT spectral imaging fails to differentiate metastatic lymphadenopathy of lung adenocarcinoma and lung squamous cell carcinoma, it is also a promising method of distinguishing metastatic

  17. Preliminary conceptual studies of REX 2000

    International Nuclear Information System (INIS)

    Merchie, F.; Baas, C.; Ballagny, A.; Chagrot, M.; Farny, G.; Barnier, M.; Pattou, A.

    1993-01-01

    Nuclear R and D programs are, to some extent, completely dependent on research reactors availability. In France and others european countries, the major materials testings reactors were built in the sixties and are consequently ageing and reaching the end of their life, some of them having already been shut down. A situation with not a single large research reactor available in first half of next century cannot be imagined, given all the benefits drawn from the use of research reactors. The CEA has therefore started to evaluate the needs for neutron sources in the next four or five decades so as to design the most suitable new facilities to take over from the existing ones. REX 2000 is a new dedicated reactor project intended to meet the needs for fuels and materials testings after the year 2000. The preliminary conceptual studies which have been carried out along the last 18 months are presented and commented. (author)

  18. Preliminary assessment of fluorine-18 fluorodeoxyglucose positron emission tomography in patients with bladder cancer

    International Nuclear Information System (INIS)

    Kosuda, S.; Kison, P.V.; Greenough, R.; Grossman, H.B.; Wahl, R.L.

    1997-01-01

    The purpose of this study was to assess the feasibility of imaging of bladder cancer with fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) scanning. We studied 12 patients with histologically proven bladder cancer who had undergone surgical procedures and/or radiotherapy. Retrograde irrigation of the urinary bladder with 1000-3710 ml saline was performed during nine of the studies. Dynamic and static PET images were obtained, and standardized uptake value images were reconstructed. FDG-PET scanning was true-positive in eight patients (66.7%), but false-negative in four (33.3%). Of 20 organs with tumor mass lesions confirmed pathologically or clinically, 16 (80%) were detected by FDG-PET scanning. FDG-PET scanning detected all of 17 distant metastatic lesions and two of three proven regional lymph node metastases. FDG-PET was also capable of differentiating viable recurrent bladder cancer from radiation-induced alterations in two patients. In conclusion, these preliminary data indicate the feasibility of FDG-PET imaging in patients with bladder cancer, although a major remaining pitfall is intense FDG accumulation in the urine. (orig.). With 3 figs., 1 tab

  19. Visualisation of latent fingermarks on polymer banknotes using copper vacuum metal deposition: A preliminary study.

    Science.gov (United States)

    Davis, Lloyd W L; Kelly, Paul F; King, Roberto S P; Bleay, Stephen M

    2016-09-01

    The UK's recent move to polymer banknotes has seen some of the currently used fingermark enhancement techniques for currency potentially become redundant, due to the surface characteristics of the polymer substrates. Possessing a non-porous surface with some semi-porous properties, alternate processes are required for polymer banknotes. This preliminary investigation explored the recovery of fingermarks from polymer notes via vacuum metal deposition using elemental copper. The study successfully demonstrated that fresh latent fingermarks, from an individual donor, could be clearly developed and imaged in the near infrared. By varying the deposition thickness of the copper, the contrast between the fingermark minutiae and the substrate could be readily optimised. Where the deposition thickness was thin enough to be visually indistinguishable, forensic gelatin lifters could be used to lift the fingermarks. These lifts could then be treated with rubeanic acid to produce a visually distinguishable mark. The technique has shown enough promise that it could be effectively utilised on other semi- and non-porous substrates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  1. In vivo bioprinting for computer- and robotic-assisted medical intervention: preliminary study in mice

    Energy Technology Data Exchange (ETDEWEB)

    Keriquel, Virginie; Guillemot, Fabien; Arnault, Isabelle; Guillotin, Bertrand; Amedee, Joelle; Fricain, Jean-Christophe; Catros, Sylvain [INSERM, U577, Bordeaux, F-33076 (France) and Universite Victor Segalen Bordeaux 2, UMR-S577 Bordeaux, F-33076 (France); Miraux, Sylvain [Centre de Resonance Magnetique des Systemes Biologiques, UMR 5536 (France)

    2010-03-15

    We present the first attempt to apply bioprinting technologies in the perspective of computer-assisted medical interventions. A workstation dedicated to high-throughput biological laser printing has been designed. Nano-hydroxyapatite (n-HA) was printed in the mouse calvaria defect model in vivo. Critical size bone defects were performed in OF-1 male mice calvaria with a 4 mm diameter trephine. Prior to laser printing experiments, the absence of inflammation due to laser irradiation onto mice dura mater was shown by means of magnetic resonance imaging. Procedures for in vivo bioprinting and results obtained using decalcified sections and x-ray microtomography are discussed. Although heterogeneous, these preliminary results demonstrate that in vivo bioprinting is possible. Bioprinting may prove to be helpful in the future for medical robotics and computer-assisted medical interventions.

  2. In vivo bioprinting for computer- and robotic-assisted medical intervention: preliminary study in mice

    International Nuclear Information System (INIS)

    Keriquel, Virginie; Guillemot, Fabien; Arnault, Isabelle; Guillotin, Bertrand; Amedee, Joelle; Fricain, Jean-Christophe; Catros, Sylvain; Miraux, Sylvain

    2010-01-01

    We present the first attempt to apply bioprinting technologies in the perspective of computer-assisted medical interventions. A workstation dedicated to high-throughput biological laser printing has been designed. Nano-hydroxyapatite (n-HA) was printed in the mouse calvaria defect model in vivo. Critical size bone defects were performed in OF-1 male mice calvaria with a 4 mm diameter trephine. Prior to laser printing experiments, the absence of inflammation due to laser irradiation onto mice dura mater was shown by means of magnetic resonance imaging. Procedures for in vivo bioprinting and results obtained using decalcified sections and x-ray microtomography are discussed. Although heterogeneous, these preliminary results demonstrate that in vivo bioprinting is possible. Bioprinting may prove to be helpful in the future for medical robotics and computer-assisted medical interventions.

  3. SPECT imaging of dopaminergic system: a preliminary study of nine patients with clinically uncertain Parkinsonism

    International Nuclear Information System (INIS)

    Dey, S. K.; Gopinath, G.; Buscombe, J. R.

    2004-01-01

    Parkinsonism is the result of various neuro degenerative disorders, the common and related causes are Parkinson's disease (PD), multiple system atrophy (MSA) and progressive supranuclear palsy (PSP). In each of these three causes, there is degeneration of presynaptic neurons in corpus striatum. Nine patients having clinically uncertain parkinsonian symptoms undergone brain SPECT imaging using the tracer (I-123 Ioflupane) that binds to dopamine transporter (DaT) in the pre-synaptic nerve terminals in basal ganglia. There was significantly decreased tracer uptake in the tail (putamen) portion of basal ganglia in five patients confirming presence of presynaptic neuro degeneration and reported as parkinsonism. Three patients revealed normal tracer uptake with one equivocal result. DaT imaging can effectively confirm parkinsonism and discriminate from normal subjects as well as other clinical simulators like essential tremor and dopa-responsive dystonia where no neuro degeneration occur.(author)

  4. Nuclear research reactor IEA-R1 heat exchanger inlet nozzle flow - a preliminary study

    International Nuclear Information System (INIS)

    Angelo, Gabriel; Andrade, Delvonei Alves de; Fainer, Gerson; Angelo, Edvaldo

    2009-01-01

    As a computational fluid mechanics training task, a preliminary model was developed. ANSYS-CFX R code was used in order to study the flow at the inlet nozzle of the heat exchanger of the primary circuit of the nuclear research reactor IEA-R1. The geometry of the inlet nozzle is basically compounded by a cylinder and two radial rings which are welded on the shell. When doing so there is an offset between the holes through the shell and the inlet nozzle. Since it is not standardized by TEMA, the inlet nozzle was chosen for a preliminary study of the flow. Results for the proposed model are presented and discussed. (author)

  5. TSPO Imaging in Glioblastoma Multiforme

    DEFF Research Database (Denmark)

    Jensen, Per; Feng, Ling; Law, Ian

    2015-01-01

    -CLINDE is superior to (18)F-FET in predicting progression of glioblastoma multiforme (GBM) at follow-up. METHODS: Three patients with World Health Organization grade IV GBM were scanned with (123)I-CLINDE SPECT, (18)F-FET PET, and gadolinium-enhanced MR imaging. Molecular imaging data were compared with follow......-CLINDE (15%-30%). In contrast, VOIs of increased contrast enhancement at follow-up compared with baseline overlapped to a greater extent with baseline (123)I-CLINDE VOIs than (18)F-FET VOIs (21% vs. 8% and 72% vs. 55%). CONCLUSION: Our preliminary results suggest that TSPO brain imaging in GBM may...... be a useful tool for predicting tumor progression at follow-up and may be less susceptible to changes in blood-brain barrier permeability than (18)F-FET. Larger studies are warranted to test the clinical potential of TSPO imaging in GBM, including presurgical planning and radiotherapy....

  6. Two preliminary studies on sleep and psychotherapy.

    Science.gov (United States)

    Karle, W; Hopper, M; Corriere, R; Hart, J; Switzer, A

    1977-09-01

    Two preliminary studies were conducted to assess the effects of an intensive outpatient psychotherapy, Feeling Therapy, on sleep. This therapy was chosen because of its demonstrated ability to affect its patients' dreams. In the first study a newly entering female patient was recorded across the first three weeks of intensive daily therapy. In contrast to two control subjects recorded across a similar time period, she demonstrated low REM times and short REM latencies on the average, and considerably greater variability in nearly every parameter. In the second study, two patients were recorded across three days (the middle of which was the day of a therapy session) first when new in therapy and then again after two and one-half years of therapy. It was found that when new in therapy both subjects spent nights of significantly altered sleep the day of the therapy session. One subject showed no REM sleep whatsoever while the other showed a 10 min REM latency and low REM time. The significance of these findings and the direction of future research is discussed.

  7. A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

    Science.gov (United States)

    Ko, Toshiyuki; Utanohara, Yuko; Suzuki, Yasuhiro; Kurihara, Makiko; Iguchi, Nobuo; Umemura, Jun; Sumiyoshi, Tetsuya; Tomoike, Hitonobu

    2016-01-01

    Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)Tl

  8. Occupational Therapy in the Context of Head Start: A Preliminary Survey Study

    Science.gov (United States)

    Bowyer, Patricia; Moore, Cary C.; Thom, Carly

    2016-01-01

    This preliminary, descriptive study yields information on the utilization of occupational therapy services within Head Start programs. Participants completed an Internet-based survey of 25 questions pertaining to the understanding, scope, and utilization of occupational therapy services. Surveys were completed by 35 respondents nationwide. A total…

  9. An evaluation of the Aerie Real campaign: Potential for promoting positive body image?

    Science.gov (United States)

    Convertino, Alexandra D; Rodgers, Rachel F; Franko, Debra L; Jodoin, Adriana

    2016-11-01

    This study evaluated the impact on young women's body satisfaction of an advertising campaign: Aerie Real, which included images of models who were not digitally modified. In total, 200 female students were randomly allocated to view either Aerie Real images or digitally modified images from previous campaigns. In the total sample, no condition differences appeared. However, participants with high appearance comparison reported a smaller decrease in body satisfaction after viewing the Aerie Real images as compared to those viewing previous images ( p = .003). Findings provide preliminary support for the Aerie Real campaign as less deleterious form of media for body image.

  10. Imaging the Intracranial Atherosclerotic Vessel Wall Using 7T MRI : Initial Comparison with Histopathology

    NARCIS (Netherlands)

    van der Kolk, A. G.; Zwanenburg, J. J. M.; Denswil, N. P.; Vink, A.; Spliet, W. G. M.; Daemen, M. J. A. P.; Visser, F.; Klomp, D. W. J.; Luijten, P. R.; Hendrikse, J.

    In this preliminary study, 7T imaging was capable of identifying not only intracranial wall thickening but different plaque components such as foamy macrophages and collagen. Signal heterogeneity was typical of advanced atherosclerotic disease. BACKGROUND AND PURPOSE: Several studies have attempted

  11. Radiolabeled antifibrin antibody in the detection of venous thrombosis: Preliminary results

    International Nuclear Information System (INIS)

    Alavi, A.; Palevsky, H.I.; Gupta, N.; Meranze, S.; Kelley, M.A.; Jatlow, A.D.; Schaible, T.F.; Brown, J.; Berger, H.J.

    1990-01-01

    The recent development of monoclonal antibodies against components of coagulated blood may provide new approaches to the diagnosis of venous thrombosis. Scanning with an indium-111-labeled Fab fragment of a murine monoclonal antifibrin antibody (59D8) and ascending contrast venography were performed in 33 patients. Images of the calves, popliteal fossae, thighs, and pelvis were obtained immediately, 4-6 hours, and 24 hours after injection of 2 mCi (74 MBq) of the antibody. All images were read in a blinded manner. Findings in both studies were positive in 28 patients and negative in three. In 19 patients not undergoing heparin therapy, 19 specific anatomic sites were positive on venograms and 29 were positive on antibody images (19 sites matched). In 14 patients undergoing heparin therapy, 34 sites were positive on venograms and 27 were positive on antibody images (22 sites matched). In most patients, positive results were noted within 1 hour of antibody injection. No adverse effects were noted with the antibody preparation. Preliminary data suggest that antifibrin antibody imaging is sensitive in detecting clots, is safe to use, and may have a role in diagnosing and managing venous thrombosis

  12. Synthesis and preliminary biological evaluation of new radioiodinated MMP inhibitors for imaging MMP activity in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Kopka, Klaus E-mail: kopka@uni-muenster.de; Breyholz, Hans-Joerg; Wagner, Stefan; Law, Marilyn P.; Riemann, Burkhard; Schroeer, Sandra; Trub, Monika; Guilbert, Benedicte; Levkau, Bodo; Schober, Otmar; Schaefers, Michael

    2004-02-01

    Non-invasive measurement of matrix metalloproteinase (MMP) activity in vivo is a clinical challenge in many disease processes such as inflammation, tumor metastasis and atherosclerosis. Therefore, radioiodinated analogues of the non-peptidyl broad-spectrum MMP inhibitor (MMPI) CGS 27023A 1a were synthesized for non-invasive detection of MMP activity in vivo using single photon emission computed tomography (SPECT). The compounds Br-CGS 27023A 1b and HO-CGS 27023A 1d were synthesized from the amino acid D-valine and used as precursors for radioiodinated derivatives of CGS 27023A and their non-radioactive references I-CGS 27023A 1c and HO-I-CGS 27023A 1e. Radioiodination of the precursors with [{sup 123}I]NaI or [{sup 125}I]NaI produced the no-carrier-added MMP inhibitors [{sup 123}I]I-CGS 27023A 1f, [{sup 125}I]I-CGS 27023A 1g, HO-[{sup 123}I]I-CGS27023A 1h, and HO-[{sup 125}I]I-CGS 27023A 1i. In vitro studies showed that the non-radioactive analogues of the MMP inhibitors exhibited affinities against gelatinase A (MMP-2) and gelatinase B (MMP-9) in the nanomolar range, comparable to the parent compound CGS 27023A. In vivo biodistribution using HO-[{sup 125}I]I-CGS 27023A 1i in CL57 Bl6 mice showed rapid blood and plasma clearance and low retention in normal tissues. The preliminary biological evaluation warrant further studies of these radioiodinated MMP inhibitors as potential new radiotracers for imaging MMP activity in vivo.

  13. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  14. Preliminary study of slow and fast ultrasonic waves using MR images of trabecular bone phantom

    Energy Technology Data Exchange (ETDEWEB)

    Solis-Najera, S. E., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx; Neria-Pérez, J. A., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx; Medina, L., E-mail: solisnajera@ciencias.unam.mx, E-mail: angel.perez@ciencias.unam.mx, E-mail: lucia.medina@ciencias.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, México, DF 04510 (Mexico); Garipov, R., E-mail: ruslan.garipov@mrsolutions.co.uk [MR Solutions Ltd, Surrey (United Kingdom); Rodríguez, A. O., E-mail: arog@xanum.uam.mx [Departamento Ingeniería Eléctrica, Universidad Autónoma Metropolitana Iztapalapa, México, DF 09340 (Mexico)

    2014-11-07

    Cancellous bone is a complex tissue that performs physiological and biomechanical functions in all vertebrates. It is made up of trabeculae that, from a simplified structural viewpoint, can be considered as plates and beams in a hyperstatic structure that change with time leading to osteoporosis. Several methods has been developed to study the trabecular bone microstructure among them is the Biot’s model which predicts the existence of two longitudinal waves in porous media; the slow and the fast waves, that can be related to porosity of the media. This paper is focused on the experimental detection of the two Biot’s waves of a trabecular bone phantom, consisting of a trabecular network of inorganic hydroxyapatite. Experimental measurements of both waves were performed using through transmission ultrasound. Results had shown clearly that the propagation of two waves propagation is transversal to the trabecular alignment. Otherwise the waves are overlapped and a single wave seems to be propagated. To validate these results, magnetic resonance images were acquired to assess the trabecular direction, and to assure that the pulses correspond to the slow and fast waves. This approach offers a methodology for non-invasive studies of trabecular bones.

  15. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Balvay, Daniel; Aubert, Emilie; Bazot, Marc; Darai, Emile; Rouzier, Roman; Cuenod, Charles A.

    2012-01-01

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F T ), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F T , Vb, rAUC and lower Ve than benign tumours (P T was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F T and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  16. Bromine-77-labeled estrogen receptor-binding radiopharmaceuticals for breast tumor imaging

    International Nuclear Information System (INIS)

    McElvany, K.D.

    1985-01-01

    Two derivatives of 16α-bromoestradiol, both with and without an 11β-methoxy substituent, have been labeled with bromine-77 and evaluated as potential breast tumor imaging agents. Extensive characterization of these radiotracers in animal models has demonstrated their effective concentration in estrogen target tissues. Preliminary clinical studies have demonstrated the potential of radiolabeled estrogens for breast tumor imaging; however, the suboptimal decay properties of bromine-77 limit the utility of these agents in imaging studies. These results with 77 -Br-labeled estrogens suggest that estrogen derivatives labeled with other radionuclides should provide enhanced image resolution with various imaging devices. Although the decay characteristics of bromine-77 are such that it is not ideally suited to imaging with conventional gamma cameras, it may be a useful radionuclide for therapeutic applications

  17. Functional magnetic resonance imaging (fMRI of attention processes in presumed obligate carriers of schizophrenia: preliminary findings

    Directory of Open Access Journals (Sweden)

    Morris Robin G

    2008-10-01

    Full Text Available Abstract Background Presumed obligate carriers (POCs are the first-degree relatives of people with schizophrenia who, although do not exhibit the disorder, are in direct lineage of it. Thus, this subpopulation of first-degree relatives could provide very important information with regard to the investigation of endophenotypes for schizophrenia that could clarify the often contradictory findings in schizophrenia high-risk populations. To date, despite the extant literature on schizophrenia endophenotypes, we are only aware of one other study that examined the neural mechanisms that underlie cognitive abnormalities in this group. The aim of this study was to investigate whether a more homogeneous group of relatives, such as POCs, have neural abnormalities that may be related to schizophrenia. Methods We used functional magnetic resonance imaging (fMRI to collect blood oxygenated level dependent (BOLD response data in six POCs and eight unrelated healthy controls while performing under conditions of sustained, selective and divided attention. Results The POCs indicated alterations in a widely distributed network of regions involved in attention processes, such as the prefrontal and temporal (including the parahippocampal gyrus cortices, in addition to the anterior cingulate gyrus. More specifically, a general reduction in BOLD response was found in these areas compared to the healthy participants during attention processes. Conclusion These preliminary findings of decreased activity in POCs indicate that this more homogeneous population of unaffected relatives share similar neural abnormalities with people with schizophrenia, suggesting that reduced BOLD activity in the attention network may be an intermediate marker for schizophrenia.

  18. ICT and UD: Preliminary Study for Recommendations to Design Accessible University Courses.

    Science.gov (United States)

    Pagliara, Silvio Marcello; Sánchez Utgé, Marta; De Anna, Lucia

    2017-01-01

    Starting from the Universal Design in the educational context principles, the experiences gained during the FIRB project "Net@ccessibility" and the high-education courses for teachers' specialization on special education, this research will focus on preliminary studies in order to define the recommendations for designing accessible university courses.

  19. Preliminary studies of soil erosion in a valley bottom in Ibadan under ...

    African Journals Online (AJOL)

    Preliminary studies of soil erosion in a valley bottom in Ibadan under some tillage practices. EA Aiyelari, SO Oshunsanya. Abstract. No Abstract. Global Journal of Agricultural Sciences Vol. 7 (1) 2008: pp.221-228. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT ...

  20. 3.0T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging-A preliminary study.

    Science.gov (United States)

    Jungmann, Pia M; Baum, Thomas; Schaeffeler, Christoph; Sauerschnig, Martin; Brucker, Peter U; Mann, Alexander; Ganter, Carl; Bieri, Oliver; Rummeny, Ernst J; Woertler, Klaus; Bauer, Jan S

    2015-08-01

    To determine the impact of axial traction during high resolution 3.0T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. MR images of n=25 asymptomatic ankles were acquired with and without axial traction (6kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1=best, 4=worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n=8) T2 and SSFP diffusion-weighted imaging (DWI; n=8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (Pevaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P>0.05). T2 values were lower at the tibia than at the talus (P<0.001). Reproducibility was better for images with axial traction. Axial traction increased the joint space width, allowed for better visualization of cartilage surfaces and improved compartment discrimination and reproducibility of quantitative cartilage parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Preliminary study of ECE imaging concept for W7-X, using the Talbot effect in rectangular waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, Daniel; Plaum, Burkhard; Kasparek, Walter; Hirth, Thomas [IGVP, Universitaet Stuttgart (Germany); Hirsch, Matthias [Max-Planck Institut fuer Plasmaphysik, Greifswald (Germany)

    2016-07-01

    For spatially resolved measurements of Electron Cyclotron Emission (ECE) in W7-X, an imaging antenna based on a corrugated rectangular waveguide can be used. The imaging characteristics of the antenna allow a simultaneous operation at multiple angles and frequencies. As a result it is possible to localize a set of points inside the plasma, where the ECE can be measured without the need of mobile components facing the plasma.

  2. MR imaging of the knee using fat suppression technique: a preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jin Suck; Kim, Mi Hye; Cho, Jae Hyun; Park, Chang Yun; Lee, Yeon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Yong Soo [Inje University College of Medicine, Kimhae (Korea, Republic of)

    1994-03-15

    The purpose of this study is to evaluate the usefulness of fat suppression technique for MR imaging of the knee. Twenty-eight knees of 26 patients were imaged at a 1.5 T MR system. Sagittal and coronal T2-weighted spin echo imaged (SET2) and sagittal fat suppression SET2(FSSE) were obtained in all cases. We used a chemical shift imaging method for fat suppression. We compared FSSE with SET2 in terms of the conspicuity of lesions of menisci, cruciate ligaments, cartilage, bone and soft tissue of the knee. Meniscal lesions were detected on FSSE and SET2 as well. FSSE depicted the lesion more conspicuously in 6 cases. For the depiction of ACL tear, SET2 was superior to FSSE in 5 cases. FSSE was better for the visualization of the normal structure of cartilage and it also depicted the cartilaginous lesions more conspicuously in 3 cases. Though bone bruise could be detected on both techniques, FSSE was better. FSSE could provide the improved delineation of menisci, cartilage, bone bruise and other soft tissues except the injuries of anterior cruciate ligament. Although FSSE is a reliable method, it can not replace SET2. It may be used as a complemental method in the imaging of the knee.

  3. Radiogenomics of hepatocellular carcinoma: multiregion analysis-based identification of prognostic imaging biomarkers by integrating gene data—a preliminary study

    Science.gov (United States)

    Xia, Wei; Chen, Ying; Zhang, Rui; Yan, Zhuangzhi; Zhou, Xiaobo; Zhang, Bo; Gao, Xin

    2018-02-01

    Our objective was to identify prognostic imaging biomarkers for hepatocellular carcinoma in contrast-enhanced computed tomography (CECT) with biological interpretations by associating imaging features and gene modules. We retrospectively analyzed 371 patients who had gene expression profiles. For the 38 patients with CECT imaging data, automatic intra-tumor partitioning was performed, resulting in three spatially distinct subregions. We extracted a total of 37 quantitative imaging features describing intensity, geometry, and texture from each subregion. Imaging features were selected after robustness and redundancy analysis. Gene modules acquired from clustering were chosen for their prognostic significance. By constructing an association map between imaging features and gene modules with Spearman rank correlations, the imaging features that significantly correlated with gene modules were obtained. These features were evaluated with Cox’s proportional hazard models and Kaplan-Meier estimates to determine their prognostic capabilities for overall survival (OS). Eight imaging features were significantly correlated with prognostic gene modules, and two of them were associated with OS. Among these, the geometry feature volume fraction of the subregion, which was significantly correlated with all prognostic gene modules representing cancer-related interpretation, was predictive of OS (Cox p  =  0.022, hazard ratio  =  0.24). The texture feature cluster prominence in the subregion, which was correlated with the prognostic gene module representing lipid metabolism and complement activation, also had the ability to predict OS (Cox p  =  0.021, hazard ratio  =  0.17). Imaging features depicting the volume fraction and textural heterogeneity in subregions have the potential to be predictors of OS with interpretable biological meaning.

  4. Optimization of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Alberto Izquierdo Fuente

    2014-01-01

    Full Text Available On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced.

  5. Optimization of a Biometric System Based on Acoustic Images

    Science.gov (United States)

    Izquierdo Fuente, Alberto; Del Val Puente, Lara; Villacorta Calvo, Juan J.; Raboso Mateos, Mariano

    2014-01-01

    On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced. PMID:24616643

  6. The preliminary study of quantitative evaluation of salivary gland function by dynamic imaging

    International Nuclear Information System (INIS)

    Han Chunqi; Li Yaming; Li Deshun; Wang Guoli; Bai Jingming; Luo Xigui

    1999-01-01

    Objective: To evaluate the function of salivary gland by quantitative dynamic imaging. Methods: In thirty normals and twenty patients with Sjogren's syndrome (SS), absorption rate (15 min) and excretion rate (30 min) were calculated using two quantitative software. Results: Parotid and submandibular absorption rates in normal subjects were (0.26 +- 0.09)% and (0.15 +- 0.08)%, respectively; those of SS patients were (0.07 +- 0.03)% and (0.05 +- 0.04)%, t = 5.3 and 4.1, both were P < 0.01. There were markedly relativity between the two groups (r = 0.85). Conclusions: Quantitative methods of analyzing salivary function is simple, sensitive, practical reliable for evaluating salivary function and also has important clinical significance

  7. NMR imaging of bladder tumors in males. Preliminary clinical experience

    International Nuclear Information System (INIS)

    Sigal, R.; Rein, A.J.J.T.; Atlan, H.; Lanir, A.; Kedar, S.; Segal, S.

    1985-01-01

    Nuclear magnetic resonance (NMR) of the normal and pathologic bladder was performed in 10 male subjects: 5 normal volunteers, 4 with bladder primary carcinoma, 1 with bladder metastasis. All scanning was done using a superconductive magnet operating at 0.5 T. Spin echo was used as pulse sequence. The diagnosis was confirmed in all cases by NMR imaging. The ability of the technique to provide images in axial, sagital and coronal planes allowed a precise assessment of the morphology and the size of the tumors. The lack of hazards and the quality of images may promote NMR imaging to a prominent role in the diagnosis of human bladder cancer [fr

  8. Knowledge-based low-level image analysis for computer vision systems

    Science.gov (United States)

    Dhawan, Atam P.; Baxi, Himanshu; Ranganath, M. V.

    1988-01-01

    Two algorithms for entry-level image analysis and preliminary segmentation are proposed which are flexible enough to incorporate local properties of the image. The first algorithm involves pyramid-based multiresolution processing and a strategy to define and use interlevel and intralevel link strengths. The second algorithm, which is designed for selected window processing, extracts regions adaptively using local histograms. The preliminary segmentation and a set of features are employed as the input to an efficient rule-based low-level analysis system, resulting in suboptimal meaningful segmentation.

  9. Potential of ricehull communal power generation in the Philippines - a preliminary study

    International Nuclear Information System (INIS)

    Bernardo, J.Y.; Navarro, L.B.; Abito, G.F.; Lim, B.P.

    1992-01-01

    The preliminary feasibility study of utilizing ricehulls as fuel for power generation in a communal set-up involving ricemills was completed by PNOC-ERDC for the EC-AIT COGEN Programme. The study assessed the market, evaluated the patterns and level of ricehull availability, and their implications on plant operation characteristics and financial viability. Ten potential areas were studied more closely for their suitability as pilot demonstration sites. (auth.). 8 tabs.; 4 figs.; 1 ref

  10. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Service de Radiologie, Hopital Tenon, Paris (France); Balvay, Daniel [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Aubert, Emilie; Bazot, Marc [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Darai, Emile; Rouzier, Roman [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Gynaecology-Obstetrics, Paris (France); Cuenod, Charles A. [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Department of Radiology, Paris (France)

    2012-04-15

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F{sub T}), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F{sub T}, Vb, rAUC and lower Ve than benign tumours (P < 0.0001, P = 0.0006, P = 0.04 and P = 0.0002, respectively). F{sub T} was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F{sub T} and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  11. Assessing Body Image in Young Children

    Directory of Open Access Journals (Sweden)

    Kristin E. Heron

    2013-02-01

    Full Text Available The purpose of this study was to examine body image discrepancies in elementary-age children in a racially diverse sample. Body image and body image discrepancy were measured in elementary school children (N = 58 of various racial groups (35% Hispanic, 33% African American, 16% Caucasian, 14% other. Each participant was shown a set of silhouette figure drawings and reported current and ideal body sizes. Children’s body discrepancies appear to change between Grades 1 and 2. Notable discrepancies between their current and ideal figures, and their current figure and those that they believe are most attractive, are largely absent in Grade 1, but are evident in Grade 2 and older children. No substantive racial or gender differences in body image perceptions or dissatisfaction were observed in this sample. Body image dissatisfaction may begin as early as second grade in both girls and boys of various racial and ethnic backgrounds. These findings provide preliminary evidence that body discrepancies may begin much earlier than previously thought.

  12. Preliminary Tests of a New Low-Cost Photogrammetric System

    Science.gov (United States)

    Santise, M.; Thoeni, K.; Roncella, R.; Sloan, S. W.; Giacomini, A.

    2017-11-01

    This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B) single board computer connected to a PiCamera Module V2 (8 MP) and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  13. PRELIMINARY TESTS OF A NEW LOW-COST PHOTOGRAMMETRIC SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Santise

    2017-11-01

    Full Text Available This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B single board computer connected to a PiCamera Module V2 (8 MP and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  14. 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, N.; Gieseke, J.; Kuhl, C.; Lutterbey, G.; Falkenhausen, M. von; Traeber, F.; Zivanovic, O.; Schild, H.H.

    2005-01-01

    The purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7 x 1.04 x 4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; 1 is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: 1 is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner

  15. Preliminary study of MR elastography in brain tumors

    International Nuclear Information System (INIS)

    Xu Lei; Gao Peiyi; Lin Yan; Han Jiancheng; Xi Zhinong; Shen Hao

    2008-01-01

    Objective: To investigate the potential values of magnetic resonance elastography (MRE) for evaluating the brain tumor consistency in vivo. Methods: Fourteen patients with known solid brain tumor (5 male, 9 female; age range: 16-63 years) underwent brain MRE studies. Informed consent was obtained from all patients. A dedicated external force actuator for brain MRE study was developed. The actuator was fixed to the head coil. During scan, one side of the actuator was attached to the patients' head. Low frequency oscillation was produced by the actuator and caused shear waves propagating into brain tissue. The pulse sequence used in the study was phase-contrast gradient-echo sequence. Phase images of the brain were obtained and the shear waves within the brain were directly imaged. Phase images were processed with local frequency estimation (LFE) technique to obtain the elasticity image. Consistency of brain tumors was evaluated at surgery and was classified as soft, intermediate, or hard with comparison to the white matter of the brain. Correspondence of MRE evaluation with operative results was studied. Results: The elastic modulus of the tumor was lower than that of white matter in 1 patient, higher in 11 patients, and similar in 2 patients. At surgery, the tumor manifested a soft consistency in 1 patient, hard consistency in 11 patients, intermediate consistency in 2 patients. The elasticity of tumors in 14 patients evaluated by MRE was correlated with the tumor consistency on the operation. Conclusion: MRE can noninvasively display the elasticity of brain tumors in vivo, and evaluate the brain tumor consistency before operation. (authors)

  16. Preliminary study on AC superconducting machines

    International Nuclear Information System (INIS)

    Yamamoto, M.; Ishigohka, T.; Shimohka, T.; Mizukami, N.; Yamaguchi, M.

    1988-01-01

    This paper describes the issues involved in developing AC superconducting machines. In the first phase, as a preliminary experiment, a 4kVa AC superconducting coil which employs 100A class 50/60Hz superconductors is made and tested. And, in the second phase, as an extension of the 4kVa coil, a model superconducting transformer is made and examined. The transformer has a novel quench protection system with an auxiliary coil only in the low voltage side. The behavior of the overcurrent protection system is confirmed

  17. A preliminary study on electromyographic analysis of the paraspinal musculature in idiopathic scoliosis

    NARCIS (Netherlands)

    Cheung, J.; Halbertsma, J.P.; Veldhuizen, A.G.; Sluiter, W.J.; Maurits, N.M.; Cool, J.C.; van Horn, J.R.

    The paraspinal muscles have been implicated as a major causative factor in the progression of idiopathic scoliosis. Therefore, the objectives of this preliminary study were to measure the electromyographic activity (EMG) of the paraspinal muscles to determine its relationship to progression of the

  18. Thermal treatment of recycled concrete aggegate for general use in concrete. A preliminary study

    NARCIS (Netherlands)

    Larbi, J.A.; Heijnen, W.M.M.; Brouwer, J.P.; Mulder, E.

    2000-01-01

    In this paper, the results of a preliminary laboratory study to assess the effectiveness of thermally treating recycled concrete aggregate for genera) use in concrete are presented. The samples used for the study consisted of sieved fractions of crushed concrete that were subjected to various

  19. Greifswald: das Image als Faktor der Stadtentwicklung; eine qualitative Untersuchung zur Stadtmarketing-Konzeption

    OpenAIRE

    Micheel, Monika

    1995-01-01

    The present paper analyses the image of the Hither Pomeranian city of Greifswald as a preliminary study of a city marketing concept. The author determines the image formed by so-called resident "experts" by means of a qualitative poll and additionally compares that picture to the opinion of non-resident visitors to the city. The image analysis pinpoints the city's weak and strong points and indicates the components which must be discussed in order to improve the city's attractiveness and to f...

  20. Purification, crystallization and preliminary X-ray diffraction studies of parakeet (Psittacula krameri) haemoglobin.

    Science.gov (United States)

    Jaimohan, S M; Naresh, M D; Arumugam, V; Mandal, A B

    2009-10-01

    Birds often show efficient oxygen management in order to meet the special demands of their metabolism. However, the structural studies of avian haemoglobins (Hbs) are inadequate for complete understanding of the mechanism involved. Towards this end, purification, crystallization and preliminary X-ray diffraction studies have been carried out for parakeet Hb. Parakeet Hb was crystallized as the met form in low-salt buffered conditions after extracting haemoglobin from crude blood by microcentrifugation and purifying the sample by column chromatography. Good-quality crystals were grown from 10% PEG 3350 and a crystal diffracted to about 2.8 A resolution. Preliminary diffraction data showed that the Hb crystal belonged to the monoclinic system (space group C2), with unit-cell parameters a = 110.68, b = 64.27, c = 56.40 A, beta = 109.35 degrees . Matthews volume analysis indicated that the crystals contained a half-tetramer in the asymmetric unit.

  1. Development of polygonal surface version of ICRP reference phantoms: Preliminary study for posture change

    International Nuclear Information System (INIS)

    Nguyen, Tat Thang; Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong

    2013-01-01

    Even though International Commission on Radiological Protection (ICRP) officially adopted a set of adult male and female voxel phantoms as the ICRP reference phantoms, there are several critical limitations due to the nature of voxel geometry and their low voxel resolutions. In order to overcome these limitations of the ICRP phantoms, we are currently developing polygonal surface version of ICRP reference phantoms by directly converting the ICRP voxel phantoms to polygonal surface geometries. Among the many advantages of the ICRP polygonal surface phantom, especially, it is flexible and deformable. In principle, it is, therefore, possible to make the posture-changed ICRP phantoms which can provide more accurate dose values for exposure situations strongly relevant to worker's postures. As a preliminary study for developing the posture-changed ICRP phantoms, in this work we changed the posture of the preliminary version of ICRP male polygon-surface phantom constructed in the previous study. Organ doses were then compared between original and posture-changed phantoms. In the present study, we successfully changed a posture of the preliminary version of ICRP male polygon-surface phantom to the walking posture. From this results, it was explicitly shown that the polygon-surface version of the ICRP phantoms can be sufficiently modified to be various postures with the posture-changing method used in this study. In addition, it was demonstrated that phantom's posture must be considered in certain exposure situations, which can differ dose values from the conventional standing-posture phantom

  2. In vivo determination of body composition of rats using magnetic resonance imaging.

    Science.gov (United States)

    Tang, H; Vasselli, J; Wu, E; Gallagher, D

    2000-05-01

    Magnetic resonance imaging (MRI) has potential as an instrument to measure body composition because it can discriminate various soft tissues in vivo. These soft tissues include adipose tissue, muscle, organs, and brain. We report on preliminary studies using a 4.2-tesla MRI for measuring body composition in the mouse and rat. We employed image segmentation methods that include an image correction method, a necessary requirement when the images are taken in the presence of nonuniform radio-frequency (RF) coil response. The software for 3-D data segmentation, quantification, correction, image manipulation, and visualization has been developed as a research tool. This method currently is being validated.

  3. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  4. Light ion production for a future radiobiological facility at CERN: preliminary studies.

    Science.gov (United States)

    Stafford-Haworth, Joshua; Bellodi, Giulia; Küchler, Detlef; Lombardi, Alessandra; Röhrich, Jörg; Scrivens, Richard

    2014-02-01

    Recent medical applications of ions such as carbon and helium have proved extremely effective for the treatment of human patients. However, before now a comprehensive study of the effects of different light ions on organic targets has not been completed. There is a strong desire for a dedicated facility which can produce ions in the range of protons to neon in order to perform this study. This paper will present the proposal and preliminary investigations into the production of light ions, and the development of a radiobiological research facility at CERN. The aims of this project will be presented along with the modifications required to the existing linear accelerator (Linac3), and the foreseen facility, including the requirements for an ion source in terms of some of the specification parameters and the flexibility of operation for different ion types. Preliminary results from beam transport simulations will be presented, in addition to some planned tests required to produce some of the required light ions (lithium, boron) to be conducted in collaboration with the Helmholtz-Zentrum für Materialien und Energie, Berlin.

  5. Preliminary Study on Testicular Germ Cell Transplantation of Endemic Species Oryzias celebensis

    Science.gov (United States)

    Andriani, I.; Agustiani, F.; Hassan, M.; Parenrengi, A.; Inoue, K.

    2018-03-01

    The research has been conducted to study some technical steps for male germ-plasm from endemic fish species such as some species of Oryzias fish in Indonesia to preserve and propagate through germ cell transplantation technology. For preliminary research, the study was started with germ cell characterization of testes, cryopreservation of TGC and the transplantation of Oryzias celebensis as candidates for surrogate broodstock of Oryzias fish male germ plasm. The data analized included the potential number of TGC as donor, the viability of cryopreserved TGC in two types of cryoprotectans and the survival rate of O.celebensis larvae as recipient after transplantation. The result showed that the average amount of TGC yielded after dissociation was 131000 ± 31349 with 74.2 % viability of TGC each. Cryoprotectan10% DMSO +glucose yielded higher viable of TGC. More than 80 % of O.celebensis larvae survived after transplantation. In conclusion, these preliminary data of O.celebensis as surrogate broodstock candidate will support the application of TGC transplantation technology in Oryzias endemic species.

  6. Astor Pass Seismic Surveys Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Louie, John [UNR; Pullammanappallil, Satish [Optim; Faulds, James; Eisses, Amy; Kell, Annie; Frary, Roxanna; Kent, Graham

    2011-08-05

    In collaboration with the Pyramid Lake Paiute Tribe (PLPT), the University of Nevada, Reno (UNR) and Optim re-processed, or collected and processed, over 24 miles of 2d seismic-reflection data near the northwest corner of Pyramid Lake, Nevada. The network of 2d land surveys achieved a near-3d density at the Astor Pass geothermal prospect that the PLPT drilled during Nov. 2010 to Feb. 2011. The Bureau of Indian Affairs funded additional seismic work around the Lake, and an extensive, detailed single-channel marine survey producing more than 300 miles of section, imaging more than 120 ft below the Lake bottom. Optim’s land data collection utilized multiple heavy vibrators and recorded over 200 channels live, providing a state-of-the-art reflection-refraction data set. After advanced seismic analysis including first-arrival velocity optimization and prestack depth migration, the 2d sections show clear fault-plane reflections, in some areas as deep as 4000 ft, tying to distinct terminations of the mostly volcanic stratigraphy. Some lines achieved velocity control to 3000 ft depth; all lines show reflections and terminations to 5000 ft depth. Three separate sets of normal faults appear in an initial interpretation of fault reflections and stratigraphic terminations, after loading the data into the OpendTect 3d seismic visualization system. Each preliminary fault set includes a continuous trace more than 3000 ft long, and a swarm of short fault strands. The three preliminary normal-fault sets strike northerly with westward dip, northwesterly with northeast dip, and easterly with north dip. An intersection of all three fault systems documented in the seismic sections at the end of Phase I helped to locate the APS-2 and APS-3 slimholes. The seismic sections do not show the faults connected to the Astor Pass tufa spire, suggesting that we have imaged mostly Tertiary-aged faults. We hypothesize that the Recent, active faults that produced the tufa through hotspring

  7. Towards distortion-free robust image authentication

    International Nuclear Information System (INIS)

    Coltuc, D

    2007-01-01

    This paper investigates a general framework for distortion-free robust image authentication by multiple marking. First, by robust watermarking a subsampled version of image edges is embedded. Then, by reversible watermarking the information needed to recover the original image is inserted, too. The hiding capacity of the reversible watermarking is the essential requirement for this approach. Thus in case of no attacks not only image is authenticated but also the original is exactly recovered. In case of attacks, reversibility is lost, but image can still be authenticated. Preliminary results providing very good robustness against JPEG compression are presented

  8. Preliminary study for unified management of CANDU safety codes and construction of database system

    International Nuclear Information System (INIS)

    Min, Byung Joo; Kim, Hyoung Tae

    2003-03-01

    It is needed to develop the Graphical User Interface(GUI) for the unified management of CANDU safety codes and to construct database system for the validation of safety codes, for which the preliminary study is done in the first stage of the present work. The input and output structures and data flow of CATHENA and PRESCON2 are investigated and the interaction of the variables between CATHENA and PRESCON2 are identified. Furthermore, PC versions of CATHENA and PRESCON2 codes are developed for the interaction of these codes and GUI(Graphic User Interface). The PC versions are assessed by comparing the calculation results with those by HP workstation or from FSAR(Final Safety Analysis Report). Preliminary study on the GUI for the safety codes in the unified management system are done. The sample of GUI programming is demonstrated preliminarily. Visual C++ is selected as the programming language for the development of GUI system. The data for Wolsong plants, reactor core, and thermal-hydraulic experiments executed in the inside and outside of the country, are collected and classified following the structure of the database system, of which two types are considered for the final web-based database system. The preliminary GUI programming for database system is demonstrated, which is updated in the future work

  9. The preliminary study of MR diffusion weighted imaging with background body signal suppression on pulmonary diseases

    International Nuclear Information System (INIS)

    Wu Huawei; Cheng Jiejun; Xu Jianrong; Lu Qing; Ge Xin; Li Lei

    2008-01-01

    Objective: To evaluate maximum intensity projection (MIP) images and apparent diffusion coefficient (ADC) values of MR diffusion weighted imaging with background body signal suppression (DWIBS) on pulmonary diseases. Methods: Sixty-one patients with pulmonary diseases underwent DWlBS. The findings in three dimensional(3D) MIP image were observed and the ADC values of diseased region were measured. The diagnostic value of DWIBS on pulmonary diseases was evaluated. Results: Lung cancer and inflammatory disease were all demonstrated as dense intensity area on DWIBS. The mean ADC value of central lung cancer was (1.05±0.23) x 10 -3 mm 2 /s. The mean ADC value of peripheral lung cancer was (1.10 ± 0.17) x 10 -3 mm 2 /s. The mean ADC value of the inflammatory disease was (1.69 ± 0.29) x 10 -3 mm 2 /s. The mean ADC value had significant difference between peripheral lung cancer and the inflammatory disease (P<0.05). The MR sensitivity, specificity and accuracy in diagnosing the pulmonary diseases with DWIBS (86.84%, 82.60%, 85.24%, respectively) was higher than conventional MRI(78.94%, 78.26%, and 78.68%, respectively). Conclusion: DWIBS can demonstrate clearly the lesion's shape with 3D display. The quantitative measurement of ADC values is feasible. DWIBS may be a potential diagnostic method for differentiation on pulmonary diseases. (authors)

  10. NMR imaging of soft tissue tumors

    International Nuclear Information System (INIS)

    Laval-Jeantet, M.; Tobolsk, F.; Delepine, N.; Delepine, G.; Roger, B.; Cabanis, E.A.

    1986-01-01

    Preliminary findings on NMR imaging of 30 soft tissue tumors demonstrated the indispensable value of this examination (particularly when a surface antenna is used) for preoperative investigation and diagnosis of tumoral recurrence when compared with other radiologic techniques. The possible potential of NMR imaging for characterization of tissues, apart from lipoma or liposarcoma, cannot be evaluated at the present time [fr

  11. Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures

    International Nuclear Information System (INIS)

    Ohuchi, H.; Satoh, T.; Eguchi, Y.; Mori, K.

    2005-01-01

    A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of photostimulated luminescence materials, have a linear dose response up to ∼100 Gy, can accurately measure doses from 1 μGy to 10 Gy and can be used repeatedly. Because the energy dependence of IPs is rather high, the IPs were characterised in this study and a sensitivity variation of ∼13% was observed for effective energies of 32.7 to 44.7 keV, which are used in IR procedures. Simulation of actual interventional cardiology procedures showed that the variation of sensitivity was within 5%, meaning that IPs are practical for measuring skin doses during IR. Moreover, the patient data can be stored online and easily called up when IR procedures must be repeated, helping to prevent radiation injuries. (authors)

  12. Preliminary study: Formaldehyde exposure in laboratories of Sharjah university in UAE

    OpenAIRE

    Ahmed, Hafiz Omer

    2011-01-01

    Objectives : Laboratory technicians, students, and instructors are at high risk, because they deal with chemicals including formaldehyde. Thus, this preliminary study was conducted to measure the concentration of formaldehyde in the laboratories of the University of Sharjah in UAE. Materials and Methods: Thirty-two air samples were collected and analyzed for formaldehyde using National Institute for Occupational Safety and Health (NIOSH) method 3500. In this method, formaldehyde reacts with c...

  13. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  14. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    Science.gov (United States)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  15. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    International Nuclear Information System (INIS)

    Voisin, Sophie; Tourassi, Georgia D.; Pinto, Frank; Morin-Ducote, Garnetta; Hudson, Kathleen B.

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content

  16. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Sophie; Tourassi, Georgia D. [Biomedical Science and Engineering Center, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Pinto, Frank [School of Engineering, Science, and Technology, Virginia State University, Petersburg, Virginia 23806 (United States); Morin-Ducote, Garnetta; Hudson, Kathleen B. [Department of Radiology, University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37920 (United States)

    2013-10-15

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.

  17. Preliminary study of magnet design for an SSC

    International Nuclear Information System (INIS)

    Taylor, C.E.; Meuser, R.B.

    1983-08-01

    The overriding design consideration for the SSC magnets is that cost of the facility be minimized; at 8 T, approximately 40 km of bending magnets is required for each ring of a 20 TeV collider. We present some results of a parametric study of two-in-one, iron-core magnets for an SSC. These results are necessarily preliminary in nature, and are intended only to show some of the trade-offs for a wide range of the variables. We show also some results for a reference design that produces 6.5 T in the aperture at 4.4 K for a coil inside diameter of 40 mm. It is not to be inferred that we have established this to be an optimum in any sense

  18. The MSFC Collaborative Engineering Process for Preliminary Design and Concept Definition Studies

    Science.gov (United States)

    Mulqueen, Jack; Jones, David; Hopkins, Randy

    2011-01-01

    This paper describes a collaborative engineering process developed by the Marshall Space Flight Center's Advanced Concepts Office for performing rapid preliminary design and mission concept definition studies for potential future NASA missions. The process has been developed and demonstrated for a broad range of mission studies including human space exploration missions, space transportation system studies and in-space science missions. The paper will describe the design team structure and specialized analytical tools that have been developed to enable a unique rapid design process. The collaborative engineering process consists of integrated analysis approach for mission definition, vehicle definition and system engineering. The relevance of the collaborative process elements to the standard NASA NPR 7120.1 system engineering process will be demonstrated. The study definition process flow for each study discipline will be will be outlined beginning with the study planning process, followed by definition of ground rules and assumptions, definition of study trades, mission analysis and subsystem analyses leading to a standardized set of mission concept study products. The flexibility of the collaborative engineering design process to accommodate a wide range of study objectives from technology definition and requirements definition to preliminary design studies will be addressed. The paper will also describe the applicability of the collaborative engineering process to include an integrated systems analysis approach for evaluating the functional requirements of evolving system technologies and capabilities needed to meet the needs of future NASA programs.

  19. Predicting methylphenidate response in attention deficit hyperactivity disorder: a preliminary study.

    Science.gov (United States)

    Johnston, Blair A; Coghill, David; Matthews, Keith; Steele, J Douglas

    2015-01-01

    Methylphenidate (MPH) is established as the main pharmacological treatment for patients with attention deficit hyperactivity disorder (ADHD). Whilst MPH is generally a highly effective treatment, not all patients respond, and some experience adverse reactions. Currently, there is no reliable method to predict how patients will respond, other than by exposure to a trial of medication. In this preliminary study, we sought to investigate whether an accurate predictor of clinical response to methylphenidate could be developed for individual patients, using sociodemographic, clinical and neuropsychological measures. Of the 43 boys with ADHD included in this proof-of-concept study, 30 were classed as responders and 13 as non-responders to MPH, with no significant differences in age nor verbal intelligence quotient (IQ) between the groups. Here we report the application of a multivariate analysis approach to the prediction of clinical response to MPH, which achieved an accuracy of 77% (p = 0.005). The most important variables to the classifier were performance on a 'go/no go' task and comorbid conduct disorder. This preliminary study suggested that further investigation is merited. Achieving a highly significant accuracy of 77% for the prediction of MPH response is an encouraging step towards finding a reliable and clinically useful method that could minimise the number of children needlessly being exposed to MPH. © The Author(s) 2014.

  20. Preliminary study on lithium-salt aqueous solution blanket

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Naruse, Yuji; Yamaoka, Mitsuaki; Ohara, Atsushi; Ono, Kiyoshi; Kobayashi, Shigetada.

    1992-06-01

    Aqueous solution blanket using lithium salts such as LiNO 3 and LiOH have been studied in the US-TIBER program and ITER conceptual design activity. In the JAERI/LANL collaboration program for the joint operation of TSTA (Tritium Systems Test Assembly), preliminary design work of blanket tritium system for lithium ceramic blanket, aqueous solution blanket and liquid metal blanket, have been performed to investigate technical feasibility of tritium demonstration tests using the TSTA. Detail study of the aqueous solution blanket concept have not been performed in the Japanese fusion program, so that this study was carried out to investigate features of its concept and to evaluated its technical problems. The following are the major items studied in the present work: (i) Neutronics of tritium breeding ratio and shielding performance Lithium concentration, Li-60 enrichment, beryllium or lead, composition of structural material/beryllium/solution, heavy water, different lithium-salts (ii) Physicochemical properties of salts Solubility, corrosion characteristics and compatibility with structural materials, radiolysis (iii) Estimation of radiolysis in ITER aqueous solution blanket. (author)

  1. Wind farm layout optimization in complex terrain: A preliminary study on a Gaussian hill

    DEFF Research Database (Denmark)

    Feng, Ju; Shen, Wen Zhong

    2014-01-01

    this problem for WFs in flat terrain or offshore has been investigated in many studies, it is still a challenging problem for WFs in complex terrain. In this preliminary study, the wind flow conditions of complex terrain without WTs are first obtained from computational fluid dynamics (CFD) simulation...

  2. Diagnostic value of susceptibility-weighted imaging of abdominal wall endometriomas during the cyclic menstrual changes: A preliminary study

    International Nuclear Information System (INIS)

    Solak, Aynur; Şahin, Neslin; Genç, Berhan; Sever, Ali Rıza; Genç, Mine; Sivrikoz, Oya Nermin

    2013-01-01

    Objective: The purpose of this study is to investigate the value of susceptibility-weighted imaging (SWI) for the evaluation of cyclic morphological and hemorrhagic changes in abdominal wall endometriomas (AWE). Materials and methods: Fourteen patients with a total of 17 lesions who were admitted with complaints of abdominal wall mass and cyclic pain were evaluated by MRI. Patients were scanned during the first three days of the menstrual cycle and during the mid-cycle phase (day 13–15). In addition to conventional images SWI was performed. The signal changes within the lesions on SWI were compared and graded on both studies. Results: There was no significant difference in the size of the lesions in the early days of the menstruation compared to the mid-menstrual period. The SWI taken on mid-cycle phase showed that the center was hyperintense and the peripheral zone was hypointense in all lesions. A signal void related to increased blood and the shrinkage of complete disappearance of hyperintensity in the venter of the lesion was seen 15 (88%) of the 17 cases on the SWI series performed during the menstrual phase scan. Conclusion: SWI is a sensitive technique and has the capability to show hemorrhage and deposition of hemosiderin within the lesions. For patients suspected with AWE, valuable diagnostic findings may be obtained if the MRI examination including SWI is performed during the early and mid phase menstrual cycle

  3. Diagnostic value of susceptibility-weighted imaging of abdominal wall endometriomas during the cyclic menstrual changes: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Solak, Aynur, E-mail: aynursolak@yahoo.com [Radiology Department of Sifa University Hospital, 35240, Fevzipasa Boulvard 172/2, Basmane, Izmir (Turkey); Şahin, Neslin, E-mail: neslinshn@gmail.com [Radiology Department of Sifa University Hospital, 35240, Fevzipasa Boulvard 172/2, Basmane, Izmir (Turkey); Genç, Berhan, E-mail: be.genc@hotmail.com [Radiology Department of Sifa University Hospital, 35240, Fevzipasa Boulvard 172/2, Basmane, Izmir (Turkey); Sever, Ali Rıza, E-mail: arsever@hotmail.com [Department of Radiology, Maidstone Hospital, Breast Unit, Maidstone, Kent (United Kingdom); Genç, Mine, E-mail: drminegenc@hotmail.com [Department of Gynecology and Obstetrics, Sifa University Hospital, 35240, Fevzipasa Boulvard 172/2, Basmane, Izmir (Turkey); Sivrikoz, Oya Nermin, E-mail: onsoral@yahoo.com [Pathology Department of Sifa University Hospital, 35240, Bornova, Izmir (Turkey)

    2013-09-15

    Objective: The purpose of this study is to investigate the value of susceptibility-weighted imaging (SWI) for the evaluation of cyclic morphological and hemorrhagic changes in abdominal wall endometriomas (AWE). Materials and methods: Fourteen patients with a total of 17 lesions who were admitted with complaints of abdominal wall mass and cyclic pain were evaluated by MRI. Patients were scanned during the first three days of the menstrual cycle and during the mid-cycle phase (day 13–15). In addition to conventional images SWI was performed. The signal changes within the lesions on SWI were compared and graded on both studies. Results: There was no significant difference in the size of the lesions in the early days of the menstruation compared to the mid-menstrual period. The SWI taken on mid-cycle phase showed that the center was hyperintense and the peripheral zone was hypointense in all lesions. A signal void related to increased blood and the shrinkage of complete disappearance of hyperintensity in the venter of the lesion was seen 15 (88%) of the 17 cases on the SWI series performed during the menstrual phase scan. Conclusion: SWI is a sensitive technique and has the capability to show hemorrhage and deposition of hemosiderin within the lesions. For patients suspected with AWE, valuable diagnostic findings may be obtained if the MRI examination including SWI is performed during the early and mid phase menstrual cycle.

  4. A study on the development plan and preliminary design of proton accelerator for nuclear application

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Tae Yoon; Choi, B H; Park, C K; Chung, K S. and others

    1997-11-01

    A study on the development plan and preliminary design for the realisation of high current proton accelerator to be used as an essential component for the R and D of accelerator-driven system (ADS) for energy production and transmutation of long-lived radionuclides. Various fields of application of the accelerator such as basic nuclear physics, material science, biology, high energy physics, medicine, etc. were also investigated. From the preliminary design study, 1 GeV (20 mA) - Linac is required for the purposed of transmutation and energy production. Specification of injector, RFQ, CCTL and SL was also suggested. For the case study, a duoplasmatron ion source was designed by KAERI and fabricated by a domestic manufacturer, and the performance was also tested. (author). 71 refs., 61 tabs., 131 figs

  5. PET/CT image registration: Preliminary tests for its application to clinical dosimetry in radiotherapy

    International Nuclear Information System (INIS)

    Banos-Capilla, M. C.; Garcia, M. A.; Bea, J.; Pla, C.; Larrea, L.; Lopez, E.

    2007-01-01

    The quality of dosimetry in radiotherapy treatment requires the accurate delimitation of the gross tumor volume. This can be achieved by complementing the anatomical detail provided by CT images through fusion with other imaging modalities that provide additional metabolic and physiological information. Therefore, use of multiple imaging modalities for radiotherapy treatment planning requires an accurate image registration method. This work describes tests carried out on a Discovery LS positron emission/computed tomography (PET/CT) system by General Electric Medical Systems (GEMS), for its later use to obtain images to delimit the target in radiotherapy treatment. Several phantoms have been used to verify image correlation, in combination with fiducial markers, which were used as a system of external landmarks. We analyzed the geometrical accuracy of two different fusion methods with the images obtained with these phantoms. We first studied the fusion method used by the PET/CT system by GEMS (hardware fusion) on the basis that there is satisfactory coincidence between the reconstruction centers in CT and PET systems; and secondly the fiducial fusion, a registration method, by means of least-squares fitting algorithm of a landmark points system. The study concluded with the verification of the centroid position of some phantom components in both imaging modalities. Centroids were estimated through a calculation similar to center-of-mass, weighted by the value of the CT number and the uptake intensity in PET. The mean deviations found for the hardware fusion method were: vertical bar Δx vertical bar ±σ=3.3 mm±1.0 mm and vertical bar Δy vertical bar ±σ=3.6 mm±1.0 mm. These values were substantially improved upon applying fiducial fusion based on external landmark points: vertical bar Δx vertical bar ±σ=0.7 mm±0.8 mm and vertical bar Δy vertical bar ±σ=0.3 mm±1.7 mm. We also noted that differences found for each of the fusion methods were similar for

  6. Journal of Island Studies: preliminary ideas from 1991, and comments from 2015

    Directory of Open Access Journals (Sweden)

    Russell King

    2015-05-01

    Full Text Available Some preliminary thoughts were penned in 1991, on the founding of an academic journal devoted to the study of the world’s islands. This collated contribution is an opportunity to look back critically at what was advised then, and what has actually come to pass through Island Studies Journal. Russell King’s prescient report from 1991 is followed by a series of candid reflections by members of ISJ’s International Editorial Board.

  7. Stuttering on function words in bilingual children who stutter: A preliminary study.

    Science.gov (United States)

    Gkalitsiou, Zoi; Byrd, Courtney T; Bedore, Lisa M; Taliancich-Klinger, Casey L

    2017-01-01

    Evidence suggests young monolingual children who stutter (CWS) are more disfluent on function than content words, particularly when produced in the initial utterance position. The purpose of the present preliminary study was to investigate whether young bilingual CWS present with this same pattern. The narrative and conversational samples of four bilingual Spanish- and English-speaking CWS were analysed. All four bilingual participants produced significantly more stuttering on function words compared to content words, irrespective of their position in the utterance, in their Spanish narrative and conversational speech samples. Three of the four participants also demonstrated more stuttering on function compared to content words in their narrative speech samples in English, but only one participant produced more stuttering on function than content words in her English conversational sample. These preliminary findings are discussed relative to linguistic planning and language proficiency and their potential contribution to stuttered speech.

  8. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  9. Resilience in post-Katrina New Orleans, Louisiana: a preliminary study.

    Science.gov (United States)

    Glandon, Douglas M; Muller, Jocelyn; Almedom, Astier M

    2008-12-01

    Much scholarly and practitioner attention to the impact of Hurricane Katrina on the city of New Orleans, Louisiana has focused on the failures of government disaster prevention and management at all levels, often overlooking the human strength and resourcefulness observed in individuals and groups among the worst-affected communities. This preliminary study sought to investigate human resilience in the city of New Orleans, State of Louisiana, eighteen months after Hurricane Katrina struck the Mississippi delta region. The Sense of Coherence scale, short form (SOC-13) was administered to a sample of 41 residents of Lower Ninth Ward and adjacent Wards who had been displaced by Hurricane Katrina but were either living in or visiting their home area during March 2007. Study participants were recruited through the local branch of the Association of Community Organizations for Reform Now (ACORN), a nation-wide grassroots organization whose mission is to promote the housing rights of low and moderate-income individuals and families across the USA and in several other countries. Those who had returned to their homes had significantly higher SOC scores compared to those who were still displaced (p<0.001). Among the latter, those who were members of ACORN scored significantly higher than non-members (p<0.005), and their SOC-13 scores were not significantly different from the scores of study participants who had returned home (including both members and non-members of ACORN). The findings of this preliminary study concur with previous reports in the literature on the deleterious impact of displacement on individual and collective resilience to disasters. Relevant insight gleaned from the qualitative data gathered during the course of administering the SOC-13 scale compensate for the limitations of the small sample size as they draw attention to the importance of the study participants' sources of social support. Possible avenues for further research are outlined.

  10. ASTROSAT CZT IMAGER OBSERVATIONS OF GRB 151006A: TIMING, SPECTROSCOPY, AND POLARIZATION STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Rao, A. R.; Chand, Vikas; Hingar, M. K.; Iyyani, S.; Khanna, Rakesh; Kutty, A. P. K.; Malkar, J. P.; Paul, D. [Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai (India); Bhalerao, V. B.; Bhattacharya, D.; Dewangan, G. C.; Pawar, Pramod; Vibhute, A. M. [Inter University Center for Astronomy and Astrophysics, Pune (India); Chattopadhyay, T.; Mithun, N. P. S.; Vadawale, S. V.; Vagshette, N. [Physical Research Laboratory, Ahmedabad (India); Basak, R. [Nicolaus Copernicus Astronomical Center, Polish Academy of Sciences, Warsaw (Poland); Pradeep, P.; Samuel, Essy, E-mail: arrao@tifr.res.in [Vikram Sarabhai Space Centre, Thiruvananthapuram (India); and others

    2016-12-10

    AstroSat is a multi-wavelength satellite launched on 2015 September 28. The CZT Imager of AstroSat on its very first day of operation detected a long duration gamma-ray burst (GRB), namely GRB 151006A. Using the off-axis imaging and spectral response of the instrument, we demonstrate that the CZT Imager can localize this GRB correctly to about a few degrees, and it can provide, in conjunction with Swift , spectral parameters similar to those obtained from Fermi /GBM. Hence, the CZT Imager would be a useful addition to the currently operating GRB instruments ( Swift and Fermi ). Specifically, we argue that the CZT Imager will be most useful for the short hard GRBs by providing localization for those detected by Fermi and spectral information for those detected only by Swift . We also provide preliminary results on a new exciting capability of this instrument: the CZT Imager is able to identify Compton scattered events thereby providing polarization information for bright GRBs. GRB 151006A, in spite of being relatively faint, shows hints of a polarization signal at 100–300 keV (though at a low significance level). We point out that the CZT Imager should provide significant time resolved polarization measurements for GRBs that have fluence three times higher than that of GRB 151006A. We estimate that the number of such bright GRBs detectable by the CZT Imager is five to six per year. The CZT Imager can also act as a good hard X-ray monitoring device for possible electromagnetic counterparts of gravitational wave events.

  11. Good Feedback for bad Players? A preliminary Study of ‘juicy’ Interface feedback

    DEFF Research Database (Denmark)

    Juul, Jesper; Jason, Begy

    2016-01-01

    The theories of game feel and juiciness claim that players will feel more competent, and that a game will be perceived as being of higher quality, when players are given large amounts of redundant audiovisual feedback in response to their actions. This poster describes a preliminary empirical study...

  12. A preliminary study to find out maximum occlusal bite force in Indian individuals

    DEFF Research Database (Denmark)

    Jain, Veena; Mathur, Vijay Prakash; Pillai, Rajath

    2014-01-01

    PURPOSE: This preliminary hospital based study was designed to measure the mean maximum bite force (MMBF) in healthy Indian individuals. An attempt was made to correlate MMBF with body mass index (BMI) and some of the anthropometric features. METHODOLOGY: A total of 358 healthy subjects in the ag...

  13. Evaluation of congenital heart disease by three-dimensional MR imaging

    International Nuclear Information System (INIS)

    Vannier, M.W.; Gutierrez, F.R.; Canter, C.E.; Yoffie, R.L.; Hildebolt, C.F.

    1988-01-01

    In an evaluation of the detectability of intra-and extracardiac morphologic defects with electrocardiographically gated magnetic resonance (MR) imaging, 100 patients were studied, including ten without and 90 with abnormalities. The abnormalities included septal defects, tetrology of Fallot, pulmonary atresia, transposition of the great vessels, and others. The patients with abnormalities were studied angiographically and with echocardiographic analyses. Two radiologists with cardiac MR imaging experience evaluated the scans in a blinded fashion, and the results were analyzed by means of receiver operating characteristic analysis. The diagnostic value of routine two-dimensional cardiac MR imaging was compared with that of three-dimensional reconstruction imaging and with the results of cardiac catheterization and echocardiography. The reported sensitivity and specificity of echocardiography in the detection of congenital heart disease is comparable to that of MR imaging. The differences in diagnostic value between various modalities for the imaging of congenital heart disease may be determined from the results of the preliminary series

  14. Knowledge-based analysis and understanding of 3D medical images

    International Nuclear Information System (INIS)

    Dhawan, A.P.; Juvvadi, S.

    1988-01-01

    The anatomical three-dimensional (3D) medical imaging modalities, such as X-ray CT and MRI, have been well recognized in the diagnostic radiology for several years while the nuclear medicine modalities, such as PET, have just started making a strong impact through functional imaging. Though PET images provide the functional information about the human organs, they are hard to interpret because of the lack of anatomical information. The authors objective is to develop a knowledge-based biomedical image analysis system which can interpret the anatomical images (such as CT). The anatomical information thus obtained can then be used in analyzing PET images of the same patient. This will not only help in interpreting PET images but it will also provide a means of studying the correlation between the anatomical and functional imaging. This paper presents the preliminary results of the knowledge based biomedical image analysis system for interpreting CT images of the chest

  15. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report.

    Science.gov (United States)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p30 ml/min./1.73 m(2) (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR.

  16. MR evaluation of renal function. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Beomonte Zobel, B; Giammarile, F; Matarese, A; Gallucci, M; Mascicchi, C; Passariello, R; Di Renzi, P; Splendiani, G; Casciani, C U

    1988-01-01

    The amount of functioning renal parenchyma can be estimated by MRI by considering the ratio between the mean intensities of cortical and medullar zones of the kidney. Fifty-six patients and 5 healthy volunteers were studied by MRI in our department. Scanning was performed with a superconductive magnet system operating at 0.5 Tesla. Pulse sequence was Spin-Echo with TR 300/TE 30 ms. The cortimedullary ratio (CMR) and differentiation (CMD) were standardized and related with creatine blood levels. CMR data ranged from 1.05 to 3.00, while CMD data ranged from 0.04 to 0.50. High values (good cortico-medullary contrast) were observed in subjects with normal renal function. Patients with renal diseases had low CMR and CMD, proportionally to the degree of renal failure, as proved by laboratory findings. Our preliminary study seems to demonstrate that MRI is an useful technique in the follow-up of patients with chronic renal disease. 19 refs.

  17. White Matter Integrity in Asperger Syndrome: A Preliminary Diffusion Tensor Magnetic Resonance Imaging Study in Adults

    NARCIS (Netherlands)

    Bloemen, Oswald J. N.; Deeley, Quinton; Sundram, Fred; Daly, Eileen M.; Barker, Gareth J.; Jones, Derek K.; van Amelsvoort, Therese A. M. J.; Schmitz, Nicole; Robertson, Dene; Murphy, Kieran C.; Murphy, Declan G. M.

    2010-01-01

    Background: Autistic Spectrum Disorder (ASD), including Asperger syndrome and autism, is a highly genetic neurodevelopmental disorder. There is a consensus that ASD has a biological basis, and it has been proposed that it is a "connectivity" disorder. Diffusion Tensor Magnetic Resonance Imaging

  18. Potential benefit of a simultaneous, side-by-side display of contrast MDCT and echocardiography over routine sequential imaging for assessment of adult congenital heart disease: A preliminary study.

    Science.gov (United States)

    Oe, Hiroki; Watanabe, Nobuhisa; Miyoshi, Toru; Osawa, Kazuhiro; Akagi, Teiji; Kanazawa, Susumu; Ito, Hiroshi

    2018-06-18

    Management of adult congenital heart disease (ACHD) patients requires understanding of its complex morphology and functional features. An innovative imaging technique has been developed to display a virtual multi-planar reconstruction obtained from contrast-enhanced multidetector-computed tomography (MDCT) corresponding to the same cross-sectional image from transthoracic echocardiography (TTE). The aim of this study is to assess the usefulness of this imaging technology in ACHD patients. This study consisted of 46 consecutive patients (30 women; mean age, 52±18 years old) with ACHD who had undergone contrast MDCT. All patients underwent TTE within a week of MDCT. An experienced sonographer who did not know the results of MDCT conducted a diagnosis using TTE and, then, using the new imaging technology. We studied whether this imaging technology provided additional or unexpected findings or makes more accurate diagnosis. In this imaging technology, MDCT cross-section provides higher-resolution image to the deep compared to corresponding TTE image. Depending on the MDCT section which can be arbitrarily set under the echo guide, we can diagnose unexpected or incremental lesions or more accurately assess the severity of the lesion in 27 patients (59%) compared to TTE study alone. This imaging technology was useful in the following situations: CONCLUSIONS: This integrated imaging technology provides incremental role over TTE in complex anatomy, and allows functional information in ACHD patients. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  19. Assessing internet addiction using the parsimonious internet addiction components model—A preliminary study.

    OpenAIRE

    Kuss, D.J.; Shorter, G.W.; Rooij, A.J. van; Griffiths, M.D.; Schoenmakers, T.M.

    2014-01-01

    Internet usage has grown exponentially over the last decade. Research indicates that excessive Internet use can lead to symptoms associated with addiction. To date, assessment of potential Internet addiction has varied regarding populations studied and instruments used, making reliable prevalence estimations difficult. To overcome the present problems a preliminary study was conducted testing a parsimonious Internet addiction components model based on Griffiths’ addiction components (Journal ...

  20. Preliminary results of a program of quality assurance applied to the image service of a public hospital

    International Nuclear Information System (INIS)

    Almeida, Claudio Domingues de; Ferreira, Rubemar de Souza; Marechal, Maria Helena H.; Milano, Nelly Ester

    2001-01-01

    Overall quality in radiological protection and medical image depend largely on keeping certain safety standards and technical procedures in good levels. In this way, in June 1998, the Ministry of Health published the document 453 - Guidelines of Radiological Protection to Medical and Dental Practices, defining different levels of actions and responsibility for radiological installation where the critical starting point was the necessity of a previous quality assurance program (QAP) into the radiological service. Preliminary results of a QAP realized in the Department of Radiology of a high complexity Hospital in Rio de Janeiro has showed that, although the importance of 453 Regulation be recognized, there is a few motivation for implementing it. Besides, during 1999 it was possible to identify film losses of 14,9 % related only to the repetition of exposures in the patients, reflecting in terms of cost about U$ 100,000 a year. Results suggest that losses of 64% of total film are due to under or over exposures and 15% are due to inadequate positioning of either film or patient, evidencing the need for training the technical and medical staff . (author)

  1. Serum Ionized Calcium Quantification for Staging Canine Periodontal Disease: A Preliminary Study.

    Science.gov (United States)

    Miguel Carreira, L; Daniela, Dias; Pedro, Azevedo

    2015-06-01

    Periodontal diseases (PD) are infectious, inflammatory, progressive diseases of the oral cavity affecting people and dogs. PD takes 2 forms: gingivitis and periodontitis. Diagnosing or staging PD can be achieved only with dental x-rays and periodontal probing, both of which require the use of general anesthesia in dogs. This study aimed to determine whether serum ionized calcium ([iCa(2+)]) levels can be useful in preliminary PD staging in dogs. A sample of 40 dogs (n = 40) was divided into 4 groups (n = 10 each) based on the following PD stages: G1 (gingivitis), G2 (initial periodontitis), G3 (moderate periodontitis), and G4 (severe periodontitis). The groups were then subjected to [iCa(2+)] quantification. Statistically significant differences were observed between PD stages and [iCa(2+)] for all stages except G3 and G4. Therefore, this parameter can be used as an additional tool to establish and monitor preliminary PD status. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A preliminary feasibility study on natural analogue in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chun Soo; Bae, Dae Seok; Kim, Kyung Su; Koh, Yong Kwon; Park, Byung Yun

    2000-03-01

    Preliminary study on the assessment of natural analogue study in Korea for the deep geological disposal of high-level radioactive waste was carried out. The project on natural analogue study in other countries are introduced. The uranium-bearing deposit in Okcheon belt are summarized, which reported to be uranium-bearing minerals in order to assess to feasibility for natural analogue study in Korea. Among the uranium-bearing deposits, the Deokpyeong area, reported to be the highest reservoir and grade, are selected as the study site, and the elementary investigation, including survey of radioactivity and geochemistry are carried out. According to the investigation of surface environment, the radioactivity and uranium content in the surface water and shallow groundwater does not show any anormal values. However, the radioactivity is expected to be increased in depth and the groundwater reacted with uranium-bearing graphite formation shows high unanium content, indicating the potential possibility for natural analogue study in Korea. In future, if more detail study are performed, the assessment of natural analogue study in Korea are expected.

  3. [Stress at work among military doctors: a preliminary study].

    Science.gov (United States)

    Knezević, Bojana; Belosević, Ljiljana

    2006-09-01

    This preliminary study examined the sources of work stress in military physicians. Forty-eight medical doctors (24 military and 24 civilian) completed a questionnaire on stressors at the work place. The participation in the study was anonymous and voluntary. Out of 24 military physicians, 14 were military general practitioners (mean age 40.5, 14 female), and 10 were consultants of different specialties (mean age 43.5, 7 male and 3 female). Civilian physicians included 13 general practitioners working at primary health care system (mean age 37, 3 male and 10 female), and 11 consultants of different specialties working at out of hospital practice (average age 37, 6 male and 5 female). The questionnaire included items aiming to obtain demographic characteristics (sex, age, marital status, children, academic degree, clinical specialty, work place, average time in practice, average time at current position) and 37 items to determine occupational stressors. The stressors were related to work management, professional demands, interpersonal and patient-doctor relationship. Differences in recognizing work stressors between the groups of civilian and military physicians were statistically analyzed by using chi-squared-test. The leading work stressors identified by military physicians were inadequate salary, being bypassed for promotion, inadequate continuous education, poor resources, poor communication with superiors, poor management, trouble with superiors, excessive paperwork, unpredictable situations, and 24-hour standby. Civilian physicians reported inadequate salary, poor resources, poor management, misinformed patients, lack of co-workers, lack of time, unpredictable situations, exposure to indictment, dealing with incurable patients and exposure to public criticism and judgment. In comparison with civilian physicians, military physicians significantly more frequently reported inadequate salary (pcommunication with superiors (pcommunication with superiors (12

  4. Preliminary studies of the biosynthesis of Austin

    International Nuclear Information System (INIS)

    Wicnienski, N.A.

    1979-01-01

    Aspergillus ustus is one of the most prevalent fungi in the soil. There are now two reports of the occurrence of toxin-producing strains of this fungus on stored foodstuffs. In addition, strains of A. ustus have been isolated along with Penicillium species from samples of South African cheeses. All A. ustus isolates tested were judged to be highly toxic to ducklings when grown on maize meal, however, the toxins involved were not isolated. Austin is the trivial name of one of the toxins made by the fungus found on stored food. Preliminary work to studying the biosynthesis of this compound using 13 C-labeled sodium acetate is reported here. The feasibility of the biosynthetic study was determined by feeding [1- 14 C]-sodium acetate to A. ustus cultures. The assignments made in the 13 C-nmr spectrum of Austin are shown. The lowest dilution factor obtained in [1- 14 C]-sodium acetate feeding experiments was 14. This dilution factor is sufficiently low to allow a successful feeding of [1,2- 13 C 2 ]-sodium acetate. A new metabolite of A. ustus, deacetylaustin, was isolated and identified. An alkaloid of unknown structure was also isolated from the fungus

  5. Mapped minerals at Questa, New Mexico, using airborne visible-infrared imaging spectrometer (AVIRIS) data -- Preliminary report

    Science.gov (United States)

    Livo, K. Eric; Clark, Roger N.

    2002-01-01

    This preliminary study for the First Quarterly Report has spectrally mapped hydrothermally altered minerals useful in assisting in assessment of water quality of the Red River. Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) data was analyzed to characterize mined and unmined ground at Questa, New Mexico. AVIRIS data covers the Red River drainage north of the river, from between the town of Questa on the west, to east of the town of Red River. The data was calibrated and analyzed using U.S. Geological Survey custom software and spectral mineral library. AVIRIS data was tested for spectral features that matched similar features in the spectral mineral library. Goodness-of-fit and band-depth were calculated for each comparison of spectral features and used to identify surface mineralogy. Mineral distribution, mineral associations, and AVIRIS pixel spectra were examined. Mineral maps show the distribution of iron hydroxides, iron sulfates, clays, micas, carbonates, and other minerals. Initial results show a system of alteration suites that overprint each other. Quartz-sericite-pyrite (QSP) alteration grading out to propylitic alteration (epidote and calcite) was identified at the Questa Mine (molybdenum porphyry) and a similar alteration pattern was mapped at the landslide (?scar?) areas. Supergene weathering overprints the altered rock, as shown by jarosite, kaolinite, and gypsum. In the spectral analysis, hydrothermally altered ground appears to be more extensive at the unmined Goat Hill Gulch and the mined ground, than the ?scars? to the east. Though the ?scars? have similar overall altered mineral suites, there are differences between the ?scars? in sericite, kaolinite, jarosite, gypsum, and calcite abundance. Fieldwork has verified the results at the central unmined ?scar? areas.

  6. Using chemical imaging to study bonding of dissimilar alloys

    International Nuclear Information System (INIS)

    Wuhrer, R.; Phillips, M.R.; Huggett, P.

    2002-01-01

    Full text: New welding techniques are currently being developed to bond very dissimilar materials such as cast irons or wear resistant steels welded to mild steel. X-ray mapping and chemical phase imaging provides useful information on the mass transport across the interface as well as phase segregation within the weld joint. Cast iron / steel and wear resistant steel / mild steel weld joints were mounted in a bakelite mount, cross-sectioned with a diamond wafering blade and polished to an optical finish using diamond abrasives. X-ray maps were collected at over a range of accelerating voltages using a Moran Scientific energy dispersive x-ray analysis and mapping system. These elemental x-ray maps were used to generate scatter plots, where pixel frequency versus element concentration profiles are plotted against each other in two or three dimensions for selected elements within the sample. The clusters observed in these plots correspond to different phases within the weld seam. The contributing pixels to each cluster can be used to reconstruct the spatial distribution of its associated phase in a chemical image of the specimen. Of particular interest to this study were the branches and links between clusters in each scatter plot and how these features correlate the chemical distribution of elements both in and around the bond region. Preliminary analysis indicated that these links and branches in the scatter plot correspond to solid solutions between chemical phases and diffusion gradients. Proper interpretation of these scatter plots will provide a better understanding of the chemical processes involved in welding dissimilar materials. Copyright (2002) Australian Society for Electron Microscopy Inc

  7. Fusing Panchromatic and SWIR Bands Based on Cnn - a Preliminary Study Over WORLDVIEW-3 Datasets

    Science.gov (United States)

    Guo, M.; Ma, H.; Bao, Y.; Wang, L.

    2018-04-01

    The traditional fusion methods are based on the fact that the spectral ranges of the Panchromatic (PAN) and multispectral bands (MS) are almost overlapping. In this paper, we propose a new pan-sharpening method for the fusion of PAN and SWIR (short-wave infrared) bands, whose spectral coverages are not overlapping. This problem is addressed with a convolutional neural network (CNN), which is trained by WorldView-3 dataset. CNN can learn the complex relationship among bands, and thus alleviate spectral distortion. Consequently, in our network, we use the simple three-layer basic architecture with 16 × 16 kernels to conduct the experiment. Every layer use different receptive field. The first two layers compute 512 feature maps by using the 16 × 16 and 1 × 1 receptive field respectively and the third layer with a 8 × 8 receptive field. The fusion results are optimized by continuous training. As for assessment, four evaluation indexes including Entropy, CC, SAM and UIQI are selected built on subjective visual effect and quantitative evaluation. The preliminary experimental results demonstrate that the fusion algorithms can effectively enhance the spatial information. Unfortunately, the fusion image has spectral distortion, it cannot maintain the spectral information of the SWIR image.

  8. Subseabed radionuclide migration studies and preliminary repository design concepts

    International Nuclear Information System (INIS)

    Brush, L.H.

    1982-01-01

    Geochemical research carried out by the US Subseabed Disposal Program is described. Data from studies of high-temperature interactions between sediments and pore water (seawater) and from studies of sorption and diffusion of radionuclides in oxidized, deep-sea sediments are used, along with results from heat transfer studies, to predict migration rates of raionuclides in a subseabed repository. Preliminary results for most radionuclides in oxidized sediments are very encouraging. Fission products with moderate K/sub D/ values (10 2 to 10 5 ml/g) and actinides with high K/sub D/ values (10 3 to 10 6 ml/g) would not migrate significant distances before decaying to innocuous concentrations. Among this group are 137 Cs, 90 Sr, and 239 Pu. The results for anionic species in oxidized sediments are less encouraging. Planning for field verification of these laboratory and modeling studies is currently under way. Conceptual repository designs and emplacement options are also described. 33 references, 15 figures, 1 table

  9. A Preliminary Study on Cathodic Prevention in Reinforced Mortar

    NARCIS (Netherlands)

    Koleva, D.A.; Van Breugel, K.; Mol, J.M.C.; De Wit, J.H.W.

    2010-01-01

    This work presents the preliminary tests on the performance of cathodic prevention (CPre) in reinforced mortar, subjected to aggressive (10% NaCl environment). Cathodic prevention is an electrochemical technique for minimizing, actually "preventing" any eventual corrosion of the steel bars in

  10. Evaluation of 3D modality-independent elastography for breast imaging: a simulation study

    International Nuclear Information System (INIS)

    Ou, J J; Ong, R E; Yankeelov, T E; Miga, M I

    2008-01-01

    This paper reports on the development and preliminary testing of a three-dimensional implementation of an inverse problem technique for extracting soft-tissue elasticity information via non-rigid model-based image registration. The modality-independent elastography (MIE) algorithm adjusts the elastic properties of a biomechanical model to achieve maximal similarity between images acquired under different states of static loading. A series of simulation experiments with clinical image sets of human breasts were performed to test the ability of the method to identify and characterize a radiographically occult stiff lesion. Because boundary conditions are a critical input to the algorithm, a comparison of three methods for semi-automated surface point correspondence was conducted in the context of systematic and randomized noise processes. The results illustrate that 3D MIE was able to successfully reconstruct elasticity images using data obtained from both magnetic resonance and x-ray computed tomography systems. The lesion was localized correctly in all cases and its relative elasticity found to be reasonably close to the true values (3.5% with the use of spatial priors and 11.6% without). In addition, the inaccuracies of surface registration performed with thin-plate spline interpolation did not exceed empiric thresholds of unacceptable boundary condition error

  11. The value of gadoxetate disodium-enhanced MR imaging for predicting posthepatectomy liver failure after major hepatic resection: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seung Hyun, E-mail: shcho2405@gmail.com [Department of Radiology, Daegu Fatima Hospital, 576-31 Sinam-dong, Dong-gu, Daegu 701-600 (Korea, Republic of); Kang, Ung Rae, E-mail: tadtail@hanmail.net [Department of Radiology, Catholic University of Daegu, School of Medicine, 3056-6 Daemyung-4-dong, Nam-gu, Daegu 705-718 (Korea, Republic of); Kim, Joo Dong, E-mail: milledr@naver.com [Department of Surgery, Catholic University of Daegu, School of Medicine, 3056-6 Daemyung-4-dong, Nam-gu, Daegu 705-718 (Korea, Republic of); Han, Young Seok, E-mail: gshyskhk@hanmail.net [Department of Surgery, Catholic University of Daegu, School of Medicine, 3056-6 Daemyung-4-dong, Nam-gu, Daegu 705-718 (Korea, Republic of); Choi, Dong Lak, E-mail: dnchoi@cu.ac.kr [Department of Surgery, Catholic University of Daegu, School of Medicine, 3056-6 Daemyung-4-dong, Nam-gu, Daegu 705-718 (Korea, Republic of)

    2011-11-15

    Purpose: To investigate whether preoperative gadoxetate-disodium-enhanced MR imaging predicts posthepatectomy liver failure (PHLF) in patients who underwent major hepatic resection. Materials and methods: Twenty nine patients who underwent preoperative gadoxetate-disodium-enhanced MR imaging and following major hepatic resection were enrolled. Hepatic parenchymal signal intensity (SI) on pre-contrast T1-weighted imaging and 20 min hepatocyte phase was measured at each of the four liver segments by two observers using region of interest measurements. The mean value was calculated and used at each phase. The relative contrast enhancement index (RCEI) was calculated: (20 min hepatocyte phase SI - pre-contrast SI)/pre-contrast SI. PHLF was determined by the International Study Group of Liver Surgery 2011 guidelines. Correlation analysis was performed between preoperative liver function test and RCEI. Diagnostic accuracy of RCEI for predicting PHLF was calculated with receiver operating characteristic curve analysis. The reproducibility of the RCEI measurement was evaluated. Results: There was a significant correlation between preoperative albumin (r = 0.496, P = 0.006), T-bilirubin (r = -0.383, P = 0.041), and RCEI. Seven patients (24%) experienced PHLF, and one of these patients (3%) died. The diagnostic accuracy of RCEI was 0.838 (sensitivity 85.7%, specificity 77.3%, cut-off value: 0.7508, 95% confidence interval: 0.654, 0.947). The 95% limits of agreement and ICC between repeated RCEI measurements were 18.4% of the mean and 0.94, respectively, and between RCEI measurements by the two observers were 21.7% and 0.929, respectively. Conclusion: Our results show that preoperative gadoxetate-disodium-enhanced MR imaging can predict PHLF in patients who underwent major hepatic resection.

  12. Basic setup for breast conductivity imaging using magnetic resonance electrical impedance tomography

    International Nuclear Information System (INIS)

    Lee, Byung Il; Oh, Suk Hoon; Kim, Tae-Seong; Woo, Eung Je; Lee, Soo Yeol; Kwon, Ohin; Seo, Jin Keun

    2006-01-01

    We present a new medical imaging technique for breast imaging, breast MREIT, in which magnetic resonance electrical impedance tomography (MREIT) is utilized to get high-resolution conductivity and current density images of the breast. In this work, we introduce the basic imaging setup of the breast MREIT technique with an investigation of four different imaging configurations of current-injection electrode positions and pathways through computer simulation studies. Utilizing the preliminary findings of a best breast MREIT configuration, additional numerical simulation studies have been carried out to validate breast MREIT at different levels of SNR. Finally, we have performed an experimental validation with a breast phantom on a 3.0 T MREIT system. The presented results strongly suggest that breast MREIT with careful imaging setups could be a potential imaging technique for human breast which may lead to early detection of breast cancer via improved differentiation of cancerous tissues in high-resolution conductivity images

  13. Work Experiences of People with Mental Illness in Malaysia: A Preliminary Qualitative Study

    Science.gov (United States)

    Boo, Su-Lyn; Loong, Jaymee; Ng, Wai-Sheng

    2011-01-01

    This is a preliminary qualitative study, using a basic interpretive approach, to investigate the work experiences of people with mental illness in Malaysia. Six females and four males (aged 30-70) from a residential home for the mentally ill participated in semi-structured interviews. Three inter-relating themes emerged, namely the experience of…

  14. Combining semantic technologies with a content-based image retrieval system - Preliminary considerations

    Science.gov (United States)

    Chmiel, P.; Ganzha, M.; Jaworska, T.; Paprzycki, M.

    2017-10-01

    Nowadays, as a part of systematic growth of volume, and variety, of information that can be found on the Internet, we observe also dramatic increase in sizes of available image collections. There are many ways to help users browsing / selecting images of interest. One of popular approaches are Content-Based Image Retrieval (CBIR) systems, which allow users to search for images that match their interests, expressed in the form of images (query by example). However, we believe that image search and retrieval could take advantage of semantic technologies. We have decided to test this hypothesis. Specifically, on the basis of knowledge captured in the CBIR, we have developed a domain ontology of residential real estate (detached houses, in particular). This allows us to semantically represent each image (and its constitutive architectural elements) represented within the CBIR. The proposed ontology was extended to capture not only the elements resulting from image segmentation, but also "spatial relations" between them. As a result, a new approach to querying the image database (semantic querying) has materialized, thus extending capabilities of the developed system.

  15. Multimodal navigated skull base tumor resection using image-based vascular and cranial nerve segmentation: A prospective pilot study.

    Science.gov (United States)

    Dolati, Parviz; Gokoglu, Abdulkerim; Eichberg, Daniel; Zamani, Amir; Golby, Alexandra; Al-Mefty, Ossama

    2015-01-01

    Skull base tumors frequently encase or invade adjacent normal neurovascular structures. For this reason, optimal tumor resection with incomplete knowledge of patient anatomy remains a challenge. To determine the accuracy and utility of image-based preoperative segmentation in skull base tumor resections, we performed a prospective study. Ten patients with skull base tumors underwent preoperative 3T magnetic resonance imaging, which included thin section three-dimensional (3D) space T2, 3D time of flight, and magnetization-prepared rapid acquisition gradient echo sequences. Imaging sequences were loaded in the neuronavigation system for segmentation and preoperative planning. Five different neurovascular landmarks were identified in each case and measured for accuracy using the neuronavigation system. Each segmented neurovascular element was validated by manual placement of the navigation probe, and errors of localization were measured. Strong correspondence between image-based segmentation and microscopic view was found at the surface of the tumor and tumor-normal brain interfaces in all cases. The accuracy of the measurements was 0.45 ± 0.21 mm (mean ± standard deviation). This information reassured the surgeon and prevented vascular injury intraoperatively. Preoperative segmentation of the related cranial nerves was possible in 80% of cases and helped the surgeon localize involved cranial nerves in all cases. Image-based preoperative vascular and neural element segmentation with 3D reconstruction is highly informative preoperatively and could increase the vigilance of neurosurgeons for preventing neurovascular injury during skull base surgeries. Additionally, the accuracy found in this study is superior to previously reported measurements. This novel preliminary study is encouraging for future validation with larger numbers of patients.

  16. Preliminary design study of a large scale graphite oxidation loop

    International Nuclear Information System (INIS)

    Epel, L.G.; Majeski, S.J.; Schweitzer, D.G.; Sheehan, T.V.

    1979-08-01

    A preliminary design study of a large scale graphite oxidation loop was performed in order to assess feasibility and to estimate capital costs. The nominal design operates at 50 atmospheres helium and 1800 F with a graphite specimen 30 inches long and 10 inches in diameter. It was determined that a simple single walled design was not practical at this time because of a lack of commercially available thick walled high temperature alloys. Two alternative concepts, at reduced operating pressure, were investigated. Both were found to be readily fabricable to operate at 1800 F and capital cost estimates for these are included. A design concept, which is outside the scope of this study, was briefly considered

  17. Compact Micro-Imaging Spectrometer (CMIS): Investigation of Imaging Spectroscopy and Its Application to Mars Geology and Astrobiology

    Science.gov (United States)

    Staten, Paul W.

    2005-01-01

    Future missions to Mars will attempt to answer questions about Mars' geological and biological history. The goal of the CMIS project is to design, construct, and test a capable, multi-spectral micro-imaging spectrometer use in such missions. A breadboard instrument has been constructed with a micro-imaging camera and Several multi-wavelength LED illumination rings. Test samples have been chosen for their interest to spectroscopists, geologists and astrobiologists. Preliminary analysis has demonstrated the advantages of isotropic illumination and micro-imaging spectroscopy over spot spectroscopy.

  18. Preliminary modulation transfer function study on amorphous silicon

    International Nuclear Information System (INIS)

    Khairul Anuar Mohd Salleh; Ab Razak Hamzah; Mohd Ashhar Khalid

    2006-01-01

    Modulation Transfer Function, (MTF) is the scientific means of evaluating the fundamental spatial resolution performance of an imaging system. In the study, the modulation transfer function of an amorphous silicon (aSi) sensor array is measured by using Edge Spread Function (ESF) Technique which is extracting a profile from the linearised image of the sharp edge. The Platinum foil is used to determine the ESF. The detector under study was a 2,304 (h) x 3,200 (v) total pixel matrix, 127 μm2 pixel pitch, 57% fill factor and using Gd2O2S:Tb Kodak Lanex Regular as the conversion screen. The ESF measurement is done by using 75 - 100 kV range of x-ray with constant mA. (Author)

  19. A functional magnetic resonance imaging study

    Indian Academy of Sciences (India)

    MADU

    systems and ultra fast imaging techniques, such as echo planar imaging (EPI ) ... is used to understand brain organization, assessing of neurological status, and ..... J C 1998 Functional MRI studies of motor recovery after stroke;. NeuroImage 7 ...

  20. [A preliminary research on multi-source medical image fusion].

    Science.gov (United States)

    Kang, Yuanyuan; Li, Bin; Tian, Lianfang; Mao, Zongyuan

    2009-04-01

    Multi-modal medical image fusion has important value in clinical diagnosis and treatment. In this paper, the multi-resolution analysis of Daubechies 9/7 Biorthogonal Wavelet Transform is introduced for anatomical and functional image fusion, then a new fusion algorithm with the combination of local standard deviation and energy as texture measurement is presented. At last, a set of quantitative evaluation criteria is given. Experiments show that both anatomical and metabolism information can be obtained effectively, and both the edge and texture features can be reserved successfully. The presented algorithm is more effective than the traditional algorithms.

  1. Quantifying the effects of iodine contrast media on standardised uptake values of FDG PET/CT images: an anthropomorphic phantom study.

    Science.gov (United States)

    Abdul Razak, Hairil Rashmizal; Nordin, Abdul Jalil; Ackerly, Trevor; Van Every, Bruce; Martin, Ruth; Geso, Moshi

    2011-09-01

    This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality.

  2. Preliminary Report: Analysis of the baseline study on the prevalence of Salmonella in laying hen flocks of Gallus gallus

    DEFF Research Database (Denmark)

    Hald, Tine

    This is a preliminary report on the analysis of the Community-wide baseline study to estimate the prevalence of Salmonella in laying hen flocks. It is being published pending the full analysis of the entire dataset from the baseline study. The report contains the elements necessary for the establ......This is a preliminary report on the analysis of the Community-wide baseline study to estimate the prevalence of Salmonella in laying hen flocks. It is being published pending the full analysis of the entire dataset from the baseline study. The report contains the elements necessary...

  3. Design and preliminary assessment of 99mTc-labeled ultrasmall superparamagnetic iron oxide-conjugated bevacizumab for single photon emission computed tomography/magnetic resonance imaging of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yanzhao Zhao; Hui Tan; Bing Wu; Pengcheng Hu; Pengyue Wu; Yushen Gu; Dengfeng Cheng; Hongcheng Shi; Qi Yao; Chunfu Zhang

    2014-01-01

    Hepatocellular carcinoma (HCC) has a very high incidence and mortality. Early diagnosis and timely treatments are therefore required to improve the quality of life and survival rate of HCC patients. Here, we developed a vascular endothelial growth factor (VEGF)-based multimodality imaging agent for single photon emission computed tomography (SPECT), computed tomography (CT) and magnetic resonance imaging (MRI) and used it to assess HCC mice and explore the combinative value of CT/MRI-based morphological imaging and SPECT functional imaging. HCC targeting with 125 I-labeled bevacizumab monoclonal antibody (mAb) was examined using SPECT/CT in HepG2 tumor-bearing mice after intravenous mAb injection. Based on this, an integrated, bimodal, VEGF-targeted, ultrasmall superparamagnetic iron oxide (USPIO)-conjugated 99m Tc-labeled bevacizumab mAb was synthesized to increase tumor penetration and accumulations. The in vivo pharmacokinetics and HepG2 tumor targeting were explored through in vivo planar imaging and SPECT/CT using a mouse model of HepG2 liver cancer. The specificity of the radiolabeled nanoparticles for HepG2 HCC was verified using in vitro immunohistochemistry and Prussian blue staining. With diethylenetriamine pentaacetic acid as a bifunctional chelating agent, USPIO-bevacizumab achieved a 99m Tc labeling efficiency of >90 %. The in vivo imaging results also exhibited the targeting of USPIO on HepG2 HCC. The specificity of these results was confirmed using in vitro immunohistochemistry and Prussian blue staining. Our preliminary findings showed the potential of USPIO as an imaging agent for the SPECT/MRI of HepG2 HCC. (author)

  4. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  5. Increased error rates in preliminary reports issued by radiology residents working more than 10 consecutive hours overnight.

    Science.gov (United States)

    Ruutiainen, Alexander T; Durand, Daniel J; Scanlon, Mary H; Itri, Jason N

    2013-03-01

    To determine if the rate of major discrepancies between resident preliminary reports and faculty final reports increases during the final hours of consecutive 12-hour overnight call shifts. Institutional review board exemption status was obtained for this study. All overnight radiology reports interpreted by residents on-call between January 2010 and June 2010 were reviewed by board-certified faculty and categorized as major discrepancies if they contained a change in interpretation with the potential to impact patient management or outcome. Initial determination of a major discrepancy was at the discretion of individual faculty radiologists based on this general definition. Studies categorized as major discrepancies were secondarily reviewed by the residency program director (M.H.S.) to ensure consistent application of the major discrepancy designation. Multiple variables associated with each report were collected and analyzed, including the time of preliminary interpretation, time into shift study was interpreted, volume of studies interpreted during each shift, day of the week, patient location (inpatient or emergency department), block of shift (2-hour blocks for 12-hour shifts), imaging modality, patient age and gender, resident identification, and faculty identification. Univariate risk factor analysis was performed to determine the optimal data format of each variable (ie, continuous versus categorical). A multivariate logistic regression model was then constructed to account for confounding between variables and identify independent risk factors for major discrepancies. We analyzed 8062 preliminary resident reports with 79 major discrepancies (1.0%). There was a statistically significant increase in major discrepancy rate during the final 2 hours of consecutive 12-hour call shifts. Multivariate analysis confirmed that interpretation during the last 2 hours of 12-hour call shifts (odds ratio (OR) 1.94, 95% confidence interval (CI) 1.18-3.21), cross

  6. Zero-gravity cloud physics laboratory: Experiment program definition and preliminary laboratory concept studies

    Science.gov (United States)

    Eaton, L. R.; Greco, E. V.

    1973-01-01

    The experiment program definition and preliminary laboratory concept studies on the zero G cloud physics laboratory are reported. This program involves the definition and development of an atmospheric cloud physics laboratory and the selection and delineations of a set of candidate experiments that must utilize the unique environment of zero gravity or near zero gravity.

  7. A Qualitative Study of Factors Influencing Racial Diversity in Environmental Education: Preliminary Results

    Science.gov (United States)

    Kathy James; Leo H. McAvoy

    1992-01-01

    This study presents preliminary result interviews with people of color working in environmental education and interpretation throughout the United States. The three primary questions asked were these? (1) What path led each individual to a career in environmental education; (2) How does each individual define environmentalism? and (3) What are the primary issues this...

  8. Preliminary economic feasibility study of MIP (Medical Isotopes Producer)

    International Nuclear Information System (INIS)

    Mon, G. H.; O, S. Y.

    2004-01-01

    Preliminary economic feasibility study of MIP (Medical Isotopes Producer), which is used liquid nuclear fuel to produce medical isotopes of Mo-99 and Sr-89, was performed. To do this, this study was estimated the IRR(Internal Rate of Return) and PBP(Pay-back Period) about optimistic and pessimistic cases for market penetration of Asia and U.S.A. isotope markets. And sensitivity analysis is also performed about capital cost and price of Mo-99 and Sr-89. According to the results, IRR was between 14.9% and 24.3%, and PBP was between 4.8 years and 7.8 years. These suggest that MIP has economic merits. MIP can produce other medical isotopes such as Sr-90, I-131, Xe-133, Cs-137. So, it is necessary to do cost-benefit analysis considering production of these other isotopes

  9. Pathologic conditions in pregnancy; Preliminary evaluation of MR efficacy. Condizioni patologiche nella gravidanza; Valutazioni preliminari sull'efficacia della Risonanza Magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Beomonte Zobel, B; Tella, S; Innacoli, M; D' Archivio, C; Cardone, G; Masciocchi, C; Gallucci, M; Passariello, R [L' Aquila Univ. (Italy). Cattedra di Radiologia; Cappa, F [L' Aquila Univ. (Italy). Clinica Ostetrica-Ginecologica

    1991-01-01

    Soma authors suggested that MR imaging could rapresent an effective diagnostic alternative in the study of pathologic conditions of mother and fetus during pregnancy. To verify the actual role of MR imaging, we examined 20 patients in the 2nd and 3rd trimester of gestation, after a preliminary US examination. Fifteen patients presented fetal or placental pathologies; in 4 patients the onset of the pathologic condition occurred during pregnancy; in 1 case of US diagnosis of fetal ascites, MR findings were nornal and the newborn was healty. As for placental pathologies, our series included a case of placental cyst, two hematomas between placenta and uterine wall, and two cases of partial placenta previa. As for fetal malformation, we evaluated a case of omphalocele, one of Prune-Belly syndrome, a case of femoral asimmetry, one of thanatophoric dwarfism, a case of thoracopagus twins with cardiovascular abnormalities, two fetal hydrocephali, and three cases of pyelo-ureteral stenosis. As for maternal pathologies during pregnancy, we observed a case of subserous uterine fibromyoma, one of of right hydronephrosis, one of protrusion of lumbar invertebral disk, and a large ovarian cyst. In our experience, MR imaging exhibited high sensitivity and a large field of view, which were both useful in the investigation of the different conditions occurring during pregnancy. In the evaluation of fetal and placental abnormalities, especially during the 3rd trimester, the diagnostic yieldof MR imaging suggested it as a complementary technique to US for the evaluation of fetal malformation and of intrauterine growth retardation.

  10. Fractal-Based Image Analysis In Radiological Applications

    Science.gov (United States)

    Dellepiane, S.; Serpico, S. B.; Vernazza, G.; Viviani, R.

    1987-10-01

    We present some preliminary results of a study aimed to assess the actual effectiveness of fractal theory and to define its limitations in the area of medical image analysis for texture description, in particular, in radiological applications. A general analysis to select appropriate parameters (mask size, tolerance on fractal dimension estimation, etc.) has been performed on synthetically generated images of known fractal dimensions. Moreover, we analyzed some radiological images of human organs in which pathological areas can be observed. Input images were subdivided into blocks of 6x6 pixels; then, for each block, the fractal dimension was computed in order to create fractal images whose intensity was related to the D value, i.e., texture behaviour. Results revealed that the fractal images could point out the differences between normal and pathological tissues. By applying histogram-splitting segmentation to the fractal images, pathological areas were isolated. Two different techniques (i.e., the method developed by Pentland and the "blanket" method) were employed to obtain fractal dimension values, and the results were compared; in both cases, the appropriateness of the fractal description of the original images was verified.

  11. Preliminary study on metallic inclusion in nuclear fuel

    International Nuclear Information System (INIS)

    Fukuzawa, Takashi; Tanaka, Masahiro; Tanabe, Tetsuo; Imoto, Shosuke

    1984-01-01

    In recent postirradiation tests, metallic fission products such as Mo, Ru, Rh and Pd are known to precipitate as metallic inclusions in the fuel. These inclusions remain as insoluble residues and provide various problems in different fields of the reprocessing. In this report are presented preliminary results of the study on the ternary phase diagram of Mo-Ru-Pd system and on their properties in nitric acid or various oxidative environments. It is concluded that (1) most of metallic inclusions which are insoluble in nitric acid show epsilon phase, Ru base hcp alloy, in which a large amount of Mo and Pd are soluble, (2) Pd, however, seems to deposit separately in the fuel pin because of its high vapor pressure, (3) Mo fraction in the inclusion would be highly dependent on oxygen potential in the fuel pin. (author)

  12. A preliminary feasibility study of passive in-core thermionic reactors for highly compact space nuclear power systems

    International Nuclear Information System (INIS)

    Parlos, A.G.; Khan, E.U.; Frymire, R.; Negron, S.; Thomas, J.K.; Peddicord, K.L.

    1991-01-01

    Results of a preliminary feasibility study on a new concept for a highly compact space reactor power systems are presented. Notwithstanding the preliminary nature of the present study, the results which include a new space reactor configuration and its associated technologies indicate promising avenues for the devleopment of highly compact space reactors. The calculations reported in this study include a neutronic design trade-off study using a two-dimensioinal neutron transport model, as well as a simplified one-dimensional thermal analysis of the reactor core. In arriving at the most desirable configuration, various options have been considered and analyzed, and their advantages/disadvantages have been compared. However, because of space limitation, only the most favorable reactor configuration is presented in this summary

  13. Developing a Physiotherapy-Specific Preliminary Clinical Decision-Making Tool for Oxygen Titration: A Modified Delphi Study

    Science.gov (United States)

    Duong, Michelle; Bertin, Kendra; Henry, Renee; Singh, Deepti; Timmins, Nolla; Brooks, Dina; Mathur, Sunita

    2014-01-01

    ABSTRACT Purpose: To develop and evaluate a preliminary clinical decision-making tool (CDMT) to assist physiotherapists in titrating oxygen for acutely ill adults in Ontario. Methods: A panel of 14 experienced cardiorespiratory physiotherapists was recruited. Factors relating to oxygen titration were identified using a modified Delphi technique. Four rounds of questionnaires were conducted, during which the goals were to (1) generate factors, (2) reduce factors and debate contentious factors, (3) finalize factors and develop the preliminary CDMT, and (4) evaluate the usability of the tool in a clinical context. Results: The panel reached consensus on a total of 89 factors, which were compiled to create the preliminary CDMT. The global tool reached consensus for sensibility, receiving a mean score of 6/7 on a 7-point Likert-type scale (1=unacceptable; 7=excellent). Five of the nine individual components of evaluation of the tool achieved scores ≥6.0; the remaining four had mean scores between 5.4 and 5.9. Conclusion: This study produced a preliminary CDMT for oxygen titration, which the panel agreed was highly comprehensible and globally sensible. Further research is necessary to evaluate the sensibility and applicability of the tool in a clinical setting. PMID:25125782

  14. Image fusion using MIM software via picture archiving and communication system

    International Nuclear Information System (INIS)

    Gu Zhaoxiang; Jiang Maosong

    2001-01-01

    The preliminary studies of the multimodality image registration and fusion were performed using an image fusion software and a picture archiving and communication system (PACS) to explore the methodology. Original image voluminal data were acquired with a CT scanner, MR and dual-head coincidence SPECT, respectively. The data sets from all imaging devices were queried, retrieved, transferred and accessed via DICOM PACS. The image fusion was performed at the SPECT ICON work-station, where the MIM (Medical Image Merge) fusion software was installed. The images were created by re-slicing original volume on the fly. The image volumes were aligned by translation and rotation of these view ports with respect to the original volume orientation. The transparency factor and contrast were adjusted in order that both volumes can be visualized in the merged images. The image volume data of CT, MR and nuclear medicine were transferred, accessed and loaded via PACS successfully. The perfect fused images of chest CT/ 18 F-FDG and brain MR/SPECT were obtained. These results showed that image fusion technique using PACS was feasible and practical. Further experimentation and larger validation studies were needed to explore the full potential of the clinical use

  15. Assessment of patient experience with unilateral vocal fold immobility: a preliminary study.

    Science.gov (United States)

    Francis, David O; McKiever, Monique E; Garrett, C Gaelyn; Jacobson, Barbara; Penson, David F

    2014-09-01

    Systematically moving toward patient-centered care for unilateral vocal fold immobility (UVFI) requires comprehensive understanding of the variability of actual patient experiences. This rigorous qualitative study assesses UVFI-related disability and proposes a preliminary taxonomy of UVFI patient experience. (1) Semistructured interviews and (2) taxonomy development. Consecutive UVFI patients presenting July to September, 2012, prospectively underwent open-ended interviews investigating how UVFI affected their quality of life (QOL) and had caused disability. Comments reported by >20% were synthesized into axes based on content similarity. Variables were arranged into a preliminary taxonomy of UVFI patient experience, which was evaluated for four attributes of face validity. The majority of 39 patients had "extensive" baseline voice use (56%) and an iatrogenic etiology (62%). Taxonomy of patient experience included three main axes of symptomatic classification: (1) voice, (2) swallowing, and (3) breathing-all with intrinsic (physical and emotional) and extrinsic (social) subaxes that describe major impacts on QOL. Voice complaints were 100% penetrant, whereas breathing and swallowing symptoms afflicted 76% and 66%, respectively, of interviewees. Of affected patients, solid and liquid dysphagia was experienced by 70% and 63%, respectively. Of dyspneic patients, shortness of breath existed with talking (97%) and exercise (72%). Persistent throat congestion (76%), weakened cough (62%), globus (62%), and dysfunctional valsalva (41%) were frequent. Patient experience with UVFI has been incompletely characterized. This qualitative assessment and preliminary taxonomy highlight several related patient experiences not well documented in the literature or incorporated into currently available metrics. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  16. Scope and purpose of the preliminary planning work

    International Nuclear Information System (INIS)

    Kalas, P.

    1976-01-01

    The results of preliminary planning work are usually expressed in a number of recommendations covering mainly: long-term national policy in the field of energy resources and selection of projects to be further studied at the feasibility level. Moreover, recommendations on further actions are made including: inventory of generation and transmission facilities recommended for the implementation in order to meet the load forecasted for medium-term period, preparation of a preliminary calender of decisions to be taken for the implementation of the projects recommended, preparation of a preliminary construction schedule, preparation of a preliminary investment program, preparation of a program of necessary engineering works, and performance of study on electricity rates which would adjust existing tariffs to proposed development program of the utility. (HP) [de

  17. Preliminary Study on Hybrid Computational Phantom for Radiation Dosimetry Based on Subdivision Surface

    International Nuclear Information System (INIS)

    Jeong, Jong Hwi; Choi, Sang Hyoun; Cho, Sung Koo; Kim, Chan Hyeong

    2007-01-01

    The anthropomorphic computational phantoms are classified into two groups. One group is the stylized phantoms, or MIRD phantoms, which are based on mathematical representations of the anatomical structures. The shapes and positions of the organs and tissues in these phantoms can be adjusted by changing the coefficients of the equations in use. The other group is the voxel phantoms, which are based on tomographic images of a real person such as CT, MR and serially sectioned color slice images from a cadaver. Obviously, the voxel phantoms represent the anatomical structures of a human body much more realistically than the stylized phantoms. A realistic representation of anatomical structure is very important for an accurate calculation of radiation dose in the human body. Consequently, the ICRP recently has decided to use the voxel phantoms for the forthcoming update of the dose conversion coefficients. However, the voxel phantoms also have some limitations: (1) The topology and dimensions of the organs and tissues in a voxel model are extremely difficult to change, and (2) The thin organs, such as oral mucosa and skin, cannot be realistically modeled unless the voxel resolution is prohibitively high. Recently, a new approach has been implemented by several investigators. The investigators converted their voxel phantoms to hybrid computational phantoms based on NURBS (Non-Uniform Rational B-Splines) surface, which is smooth and deformable. It is claimed that these new phantoms have the flexibility of the stylized phantom along with the realistic representations of the anatomical structures. The topology and dimensions of the anatomical structures can be easily changed as necessary. Thin organs can be modeled without affecting computational speed or memory requirement. The hybrid phantoms can be also used for 4-D Monte Carlo simulations. In this preliminary study, the external shape of a voxel phantom (i.e., skin), HDRK-Man, was converted to a hybrid computational

  18. Preliminary studies on the behavioural effects of the methanol ...

    African Journals Online (AJOL)

    The behavioural tests employed were diazepam-induced sleep onset and duration, hole board assay for exploratory activity, mouse beam walk assay for motor coordination, and the staircase test for the detection of anxiolytic compounds. Preliminary phytochemical screening was also carried out on the extract. Results: The ...

  19. Monte Carlo modeling of neutron imaging at the SINQ spallation source

    International Nuclear Information System (INIS)

    Lebenhaft, J.R.; Lehmann, E.H.; Pitcher, E.J.; McKinney, G.W.

    2003-01-01

    Modeling of the Swiss Spallation Neutron Source (SINQ) has been used to demonstrate the neutron radiography capability of the newly released MPI-version of the MCNPX Monte Carlo code. A detailed MCNPX model was developed of SINQ and its associated neutron transmission radiography (NEUTRA) facility. Preliminary validation of the model was performed by comparing the calculated and measured neutron fluxes in the NEUTRA beam line, and a simulated radiography image was generated for a sample consisting of steel tubes containing different materials. This paper describes the SINQ facility, provides details of the MCNPX model, and presents preliminary results of the neutron imaging. (authors)

  20. Use of thermographic imaging in clinical diagnosis of small animal: preliminary notes

    Directory of Open Access Journals (Sweden)

    Veronica Redaelli

    2014-06-01

    Full Text Available INTRODUCTION. The authors, after a description of the physics of infrared thermographic technique (IRT, analyze the reading of images and the main applications in the veterinary field, compared to the existing literature on the subject and to their experimental researches. IRT lends itself to countless applications in biology, thanks to its characteristics of versatility, lack of invasiveness and high sensitivity. Probably the major limitation to its application in the animal lies in the ease of use and in its extreme sensitivity. MATERIALS AND METHODS. From September 2009 to October 2010, the experimental investigation with the thermo camera took into consideration 110 animals (92 dogs and 18 cats, without any selection criteria. All patients were brought to the Faculty of Veterinary Medicine in Milan University by the owner, to be examined by a specialist, or to undergo one of the following diagnostic procedures: X-rays, computed tomography, or ultrasound examinations; finally some patients were brought in for surgical procedures. With the consent of the owner, 1 to 10 thermographic images were recorded from each clinical case. Results. In this first experimental investigation, thermography has shown a high sensitivity (100%, but a low specificity (44%. This figure excludes the use of thermal imaging technology to replace other imaging techniques such as radiography, computed tomography and magnetic resonance imaging. Furthermore, it does not show any ability to recognize the etiology of the disease, but only the thermal alteration, and this is restricting its use. However, this experimental study has demonstrated that thermography can be used in veterinary medicine, and specifically in dogs and cats. It is hoped that in the field of targeted diseases this technique will become an important tool for diagnostic purposes by using working protocols validated and repeatable.

  1. Gold nanoparticles : A novel application of spectral imaging in proteomics - preliminary results

    NARCIS (Netherlands)

    Dietrich, H.R.C.; Young, I.T.; Garini, Y.

    2005-01-01

    The intense research in proteomics is demanding for fast, reliable and easy-to-use methods in order to study the proteome. In this proceeding we report the development of such a novel research tool based on spectral imaging and Resonance Light Scattering gold particles. This method will allow the

  2. Preliminary design studies for the DESCARTES and CIDER codes

    International Nuclear Information System (INIS)

    Eslinger, P.W.; Miley, T.B.; Ouderkirk, S.J.; Nichols, W.E.

    1992-12-01

    The Hanford Environmental Dose Reconstruction (HEDR) project is developing several computer codes to model the release and transport of radionuclides into the environment. This preliminary design addresses two of these codes: Dynamic Estimates of Concentrations and Radionuclides in Terrestrial Environments (DESCARTES) and Calculation of Individual Doses from Environmental Radionuclides (CIDER). The DESCARTES code will be used to estimate the concentration of radionuclides in environmental pathways, given the output of the air transport code HATCHET. The CIDER code will use information provided by DESCARTES to estimate the dose received by an individual. This document reports on preliminary design work performed by the code development team to determine if the requirements could be met for Descartes and CIDER. The document contains three major sections: (i) a data flow diagram and discussion for DESCARTES, (ii) a data flow diagram and discussion for CIDER, and (iii) a series of brief statements regarding the design approach required to address each code requirement

  3. Improved cancer diagnostics by different image processing techniques on OCT images

    Science.gov (United States)

    Kanawade, Rajesh; Lengenfelder, Benjamin; Marini Menezes, Tassiana; Hohmann, Martin; Kopfinger, Stefan; Hohmann, Tim; Grabiec, Urszula; Klämpfl, Florian; Gonzales Menezes, Jean; Waldner, Maximilian; Schmidt, Michael

    2015-07-01

    Optical-coherence tomography (OCT) is a promising non-invasive, high-resolution imaging modality which can be used for cancer diagnosis and its therapeutic assessment. However, speckle noise makes detection of cancer boundaries and image segmentation problematic and unreliable. Therefore, to improve the image analysis for a precise cancer border detection, the performance of different image processing algorithms such as mean, median, hybrid median filter and rotational kernel transformation (RKT) for this task is investigated. This is done on OCT images acquired from an ex-vivo human cancerous mucosa and in vitro by using cultivated tumour applied on organotypical hippocampal slice cultures. The preliminary results confirm that the border between the healthy and the cancer lesions can be identified precisely. The obtained results are verified with fluorescence microscopy. This research can improve cancer diagnosis and the detection of borders between healthy and cancerous tissue. Thus, it could also reduce the number of biopsies required during screening endoscopy by providing better guidance to the physician.

  4. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  5. Influence of study satisfaction on academic procrastination in psychology students: a preliminary study

    Directory of Open Access Journals (Sweden)

    Sergio Alexis Dominguez-Lara

    2017-06-01

    Full Text Available The aim of this predictive study was to analyze the degree of influence of study satisfaction (SS on academic procrastination (AP. One hundred forty- eight (148 psychology students (111 women between 18 and 32 years old (M = 22.41 were evaluated using the Brief Scale of Study Satisfaction and the Academic Procrastination Scale. After preliminary analyses focused on the scores reliability (α > 0.70 and correlations between dimensions, a regression analysis was performed to determine how much of the variability in the AP dimensions’ scores is explained by the variations in the SS. For that purpose, a method that uses bivariate correlations corrected for attenuation and provides confidence intervals under a bootstrap approach of the associated statistics was applied. All analyses were assessed from an effect size approach. The results indicate that the influence of SS on AP was not significant. These findings provide new ways to implement studies in order to understand the procrastinating behavior in the university setting.

  6. Study, development and clinical evaluation of a per-operative γ imager

    International Nuclear Information System (INIS)

    Menard, Laurent

    1999-01-01

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author)

  7. Application of optical character recognition in thermal image processing

    Science.gov (United States)

    Chan, W. T.; Sim, K. S.; Tso, C. P.

    2011-07-01

    This paper presents the results of a study on the reliability of the thermal imager compared to other devices that are used in preventive maintenance. Several case studies are used to facilitate the comparisons. When any device is found to perform unsatisfactorily where there is a suspected fault, its short-fall is determined so that the other devices may compensate, if possible. This study discovered that the thermal imager is not suitable or efficient enough for systems that happen to have little contrast in temperature between its parts or small but important parts that have their heat signatures obscured by those from other parts. The thermal imager is also found to be useful for preliminary examinations of certain systems, after which other more economical devices are suitable substitutes for further examinations. The findings of this research will be useful to the design and planning of preventive maintenance routines for industrial benefits.

  8. Preliminary Study on Management of Agricultural Scientific Research Projects in the New Situation

    Institute of Scientific and Technical Information of China (English)

    Haiyan LUO; Qingqun YAO; Lizhen CHEN; Yu ZHENG

    2015-01-01

    Project management of agricultural scientific research institutions is an important section of agricultural scientific research plan management. It is of great significance for sustainable development of scientific research work of scientific research institutions. According to a series of opinions and notices about scientific and technological system reform issued by the state,and combining current situations of management of scientific research projects in scientific research institutions,this paper made a preliminary study on management of agricultural scientific research projects in the new trend. Finally,on the basis of the current situations of management of agricultural scientific research projects,it came up with pertinent recommendations,including strengthening communication and cooperation and actively declaring projects,strengthening preliminary planning of projects and establishing project information database,reinforcing project process management,ensuring on-time and high quality completion of projects,and strengthening learning and improving quality of management personnel.

  9. Preliminary study of normal changes in brain white matter during childhood with diffusion tensor imaging

    International Nuclear Information System (INIS)

    Xiao Jiangxi; Guo Xuemei; Xie Sheng; Wang Xiaoying; Jiang Xuexiang

    2005-01-01

    Objective: To study the normal changes in brain white matter during childhood by analyzing the anisotropy of different regions and different age groups with diffusion tensor imaging (DTI). Methods: DTI was performed in 89 children (age range from 2 days to 18 years) without brain abnormalities, and the data measured in fractional anisotropy (FA) maps were analyzed statistically. Children less than 6 months were ranged to group 1, 6-12 months to group 2, 1-3 years to group 3, 3-5 years to group 4, 5-8 years to group 5, 8-12 years to group 6, 12-18 years to group 7. Results: (1) There were significant differences in anisotropy (FA values) among different regions of white matter in brain. In group 7, the FA value of corpus callosum was 0.826 ± 0.039, middle cerebellar peduncle 0.678 ± 0.043, frontal white matter 0.489 ± 0.033. (2) The anisotropy among different age group was statistically different, P<0.05. (3) The anisotropy of white matter increased with the increasing of age, and FA values showed positively exponentially correlations with age. Conclusion: DTI shows the structure of white matters in vivo, with which normal changes in brain during childhood can be evaluated. (authors)

  10. High Frame-Rate Blood Vector Velocity Imaging Using Plane Waves: Simulations and Preliminary Experiments

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2008-01-01

    ) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program......, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common...... carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow...

  11. Voxel-based morphometry and diffusion tensor imaging of the optic pathway in primary open-angle glaucoma: a preliminary study.

    Science.gov (United States)

    Zikou, A K; Kitsos, G; Tzarouchi, L C; Astrakas, L; Alexiou, G A; Argyropoulou, M I

    2012-01-01

    Neuropathologic studies in experimental and human glaucoma have demonstrated degenerative changes in the optic pathway. The purpose of this study was to assess the optic pathway in POAG by using VBM and DTI. Eighteen patients 57.05 ± 11.38 years of age with POAG of 8.30 ± 5.14 years' duration and 18 control subjects underwent a complete ophthalmologic examination, including quantification of the RNFLT by using Stratus OCT 3, and brain imaging. The imaging protocol consisted of a T1-weighted high-resolution 3D spoiled gradient-echo sequence and a multisection spin-echo- planar diffusion-weighted sequence. Data preprocessing and analysis were performed by using Matlab 7.0 and SPM 5. Left temporal and right nasal RNFLTs were significantly thinner than right temporal and left nasal RNFLTs. In patients, VBM revealed a significant reduction in the left visual cortex volume, the left lateral geniculate nucleus, and the intracranial part of the ONs and the chiasma. In addition, a significant decrease of FA was observed in the inferior fronto-occipital fasciculus, the longitudinal and inferior frontal fasciculi, the putamen, the caudate nucleus, the anterior and posterior thalamic radiations, and the anterior and posterior limbs of the internal capsule of the left hemisphere (P < .05). Neurodegenerative changes of the optic pathway and several brain areas associated with the visual system can be observed by using VBM and DTI in patients with POAG, suggesting that glaucoma is a complex neurologic disease.

  12. Digital subtraction angiography of lower limb arteries using and automatic table translation. Feasibility. Preliminary results

    International Nuclear Information System (INIS)

    Seka, R.; Amiel, M.; Boller, A.; Chapelon, C.; Clermont, A.; Revel, D.; Pinet, F.

    1988-01-01

    Digital subtraction angiography (DSA) as a method of evaluating lower limb arteries required examination of one limb at a time up to now. Moreover repeated injections of contrast material were necessary. This problem was mainly due to the relative small image intensifier field available and to the difficulty of repositionning the patient between mask and image acquisition. The preliminary results obtained with 24 patients studied on angiographic unit equipped with: a DSA system (DG 300-CGR) using 512x512 matrix size, an angiographic table (Angix M 200) allowing an automatic sequantial translation, a removable image intensifier using a 16 inch field below the table, are reported. Thus, all those characteristics allow DSA of lower limb arteries. Only one injection of contrast material (Ioxaglate: 80 ml at 8-10 ml/second) was used per procedure. This, usually, allows good quality examination of lower limb arteries [fr

  13. Adult health study. Hiroshima preliminary report, 1958-1959

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, J W; Anderson, Jr, P S

    1961-06-28

    The first 4151 clinical examinations of radiation exposed and nonexposed persons in the Hiroshima Adult Health Study have been tabulated and reviewed. No evident differences in past history, medical symptoms, physical examination, laboratory findings, nor disease incidence could be related to the atomic radiation in 1945. The sample is small and represents only a portion of the first cycle of an examination procedure that is planned to continue indefinitely at approximately two year intervals. This report, consisting of a review of the program and the findings in this preliminary sample, includes extensive tabular data (Tables 28-65) from the coded medical information. It was not expected that radiation induced changes would be evident from this sample unless they were of unexpected prominence. The report was prepared primarily to describe the problems inherent in an epidemiologic medical study of this sort, and to review the type of data that can be obtained for future analyses. This analysis was conducted to pinpoint some of the problems; to assist others contemplating this type of medical study; to illuminate for ABCC the data that are being collected; and to suggest ways to use these data most effectively. 16 references, 1 figure, 65 tables.

  14. Gamma-ray imaging probes

    International Nuclear Information System (INIS)

    Wild, W.J.

    1988-01-01

    External nuclear medicine diagnostic imaging of early primary and metastatic lung cancer tumors is difficult due to the poor sensitivity and resolution of existing gamma cameras. Nonimaging counting detectors used for internal tumor detection give ambiguous results because distant background variations are difficult to discriminate from neighboring tumor sites. This suggests that an internal imaging nuclear medicine probe, particularly an esophageal probe, may be advantageously used to detect small tumors because of the ability to discriminate against background variations and the capability to get close to sites neighboring the esophagus. The design, theory of operation, preliminary bench tests, characterization of noise behavior and optimization of such an imaging probe is the central theme of this work

  15. Hypoallergenic properties of donkey's milk: a preliminary study

    Directory of Open Access Journals (Sweden)

    Silvia Vincenzetti

    2014-06-01

    Full Text Available Cow's milk protein allergy (CMPA is an abnormal immunological response to cow milk proteins, which results in IgE-mediated reactions. The therapeutic strategy to respond to CMPA envisages the total elimination of milk or the administration of cow's milk substitutes. For this reason the use of milk from other mammalian species was tested. Among them, donkey's milk proved to be the best alternative in feeding infants affected by CMPA, since its chemical composition is comparable to human milk. In this work an in vitro study was performed in order to analyze the IgE reactivity to milk protein allergens from cow, donkey and goat. In particular, immunoblotting experiments using sera from milk-allergic and non-allergic adult volunteers were conducted with the aim of verifying the hypoallergenic property of donkey's milk. This study provided a preliminary evidence of the hypoallergenicity of donkey's milk when compared to bovine and goat milk. Considering the obtained results, it would be possible to develop a sensitive diagnostic method for CMPA detection, based on chromatographic and immunoblotting analysis.

  16. Preliminary Slope Stability Study Using Slope/ W

    International Nuclear Information System (INIS)

    Nazran Harun; Mohd Abd Wahab Yusof; Kamarudin Samuding; Mohd Muzamil Mohd Hashim; Nurul Fairuz Diyana Bahrudin

    2014-01-01

    Analyzing the stability of earth structures is the oldest type of numerical analysis in geotechnical engineering. Limit equilibrium types of analyses for assessing the stability of earth slopes have been in use in geotechnical engineering for many decades. Modern limit equilibrium software is making it possible to handle ever-increasing complexity within an analysis. It is being considered as the potential method in dealing with complex stratigraphy, highly irregular pore-water pressure conditions, various linear and nonlinear shear strength models and almost any kind of slip surface shape. It allows rapid decision making by providing an early indication of the potential suitability of sites based on slope stability analysis. Hence, a preliminary slope stability study has been developed to improve the capacity of Malaysian Nuclear Agency (Nuclear Malaysia) in assessing potential sites for Borehole Disposal for Disused Sealed Radioactive Sources. The results showed that geometry of cross section A-A ' , B-B ' , C-C ' and D-D ' achieved the factor of safety not less than 1.4 and these are deemed acceptable. (author)

  17. Design of e-Science platform for biomedical imaging research cross multiple academic institutions and hospitals

    Science.gov (United States)

    Zhang, Jianguo; Zhang, Kai; Yang, Yuanyuan; Ling, Tonghui; Wang, Tusheng; Wang, Mingqing; Hu, Haibo; Xu, Xuemin

    2012-02-01

    More and more image informatics researchers and engineers are considering to re-construct imaging and informatics infrastructure or to build new framework to enable multiple disciplines of medical researchers, clinical physicians and biomedical engineers working together in a secured, efficient, and transparent cooperative environment. In this presentation, we show an outline and our preliminary design work of building an e-Science platform for biomedical imaging and informatics research and application in Shanghai. We will present our consideration and strategy on designing this platform, and preliminary results. We also will discuss some challenges and solutions in building this platform.

  18. Expression, crystallization and preliminary crystallographic study of GluB from Corynebacterium glutamicum

    International Nuclear Information System (INIS)

    Liu, Qingbo; Li, Defeng; Hu, Yonglin; Wang, Da-Cheng

    2013-01-01

    GluB, a substrate-binding protein from C. glutamicum, was expressed, purified and crystallized, followed by X-ray diffraction data collection and preliminary crystallographic analysis. GluB is a substrate-binding protein (SBP) which participates in the uptake of glutamic acid in Corynebacterium glutamicum, a Gram-positive bacterium. It is part of an ATP-binding cassette (ABC) transporter system. Together with the transmembrane proteins GluC and GluD and the cytoplasmic protein GluA, which couples the hydrolysis of ATP to the translocation of glutamate, they form a highly active glutamate-uptake system. As part of efforts to study the amino-acid metabolism, especially the metabolism of glutamic acid by C. glutamicum, a bacterium that is widely used in the industrial production of glutamic acid, the GluB protein was expressed, purified and crystallized, an X-ray diffraction data set was collected to a resolution of 1.9 Å and preliminary crystallographic analysis was performed. The crystal belonged to space group P3 1 21 or P3 2 21, with unit-cell parameters a = b = 82.50, c = 72.69 Å

  19. Imaging study on acupuncture points

    Science.gov (United States)

    Yan, X. H.; Zhang, X. Y.; Liu, C. L.; Dang, R. S.; Ando, M.; Sugiyama, H.; Chen, H. S.; Ding, G. H.

    2009-09-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  20. Imaging study on acupuncture points

    International Nuclear Information System (INIS)

    Yan, X H; Zhang, X Y; Liu, C L; Dang, R S; Ando, M; Sugiyama, H; Chen, H S; Ding, G H

    2009-01-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  1. The cost of child health inequalities in Aotearoa New Zealand: a preliminary scoping study.

    Science.gov (United States)

    Mills, Clair; Reid, Papaarangi; Vaithianathan, Rhema

    2012-05-28

    Health inequalities have been extensively documented, internationally and in New Zealand. The cost of reducing health inequities is often perceived as high; however, recent international studies suggest the cost of "doing nothing" is itself significant. This study aimed to develop a preliminary estimate of the economic cost of health inequities between Māori (indigenous) and non-Māori children in New Zealand. Standard quantitative epidemiological methods and "cost of illness" methodology were employed, within a Kaupapa Māori theoretical framework. Data were obtained from national data collections held by the New Zealand Health Information Service and other health sector agencies. Preliminary estimates suggest child health inequities between Māori and non-Māori in New Zealand are cost-saving to the health sector. However the societal costs are significant. A conservative "base case" scenario estimate is over $NZ62 million per year, while alternative costing methods yield larger costs of nearly $NZ200 million per annum. The total cost estimate is highly sensitive to the costing method used and Value of Statistical Life applied, as the cost of potentially avoidable deaths of Māori children is the major contributor to this estimate. This preliminary study suggests that health sector spending is skewed towards non-Māori children despite evidence of greater Māori need. Persistent child health inequities result in significant societal economic costs. Eliminating child health inequities, particularly in primary care access, could result in significant economic benefits for New Zealand. However, there are conceptual, ethical and methodological challenges in estimating the economic cost of child health inequities. Re-thinking of traditional economic frameworks and development of more appropriate methodologies is required.

  2. 99m Tc-tazobactam, a novel infection imaging agent: Radiosynthesis, quality control, biodistribution, and infection imaging studies.

    Science.gov (United States)

    Rasheed, Rashid; Naqvi, Syed Ali Raza; Gillani, Syed Jawad Hussain; Zahoor, Ameer Fawad; Jielani, Asif; Saeed, Nidda

    2017-05-15

    The radiolabeled drug 99m Tc-tazobactam ( 99m Tc-TZB) was developed and assessed as an infection imaging agent in Pseudomonas aeruginosa and Salmonella enterica infection-induced animal models by comparing with inflammation induced animal models. Radiosynthesis of 99m Tc-TZB was assessed while changing ligand concentration, reducing agent concentration, pH, and reaction time while keeping radioactivity constant (~370 MBq). Percent labeling of the resulting complex was measured using paper chromatography and instant thin layer chromatography. The analysis of the 99m Tc-TZB complex indicated >95% labeling yield and electrophoresis revealed complex is neutral in nature. The biodistribution study also showed predominantly renal excretion; however liver, stomach, and intestine also showed slight tracer agent uptake. The agent significantly accumulated in Pseudomonas aeruginosa and Salmonella enterica infection induced tissues 3.58 ± 0.26% and 2.43 ± 0.42% respectively at 1 hour postinjection. The inflamed tissue failed to uptake noticeable activity at 1 hour time point. The scintigraphic study results were found in accordance with biodistribution pattern. On the basis of our preliminary results, the newly developed 99m Tc-TZB can be used to diagnose bacterial infection and to discriminate between infected and inflamed tissues. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Effect of exhaustive exercise on the angular pedaling pattern: A preliminary study

    Directory of Open Access Journals (Sweden)

    Matheus Joner Wiest

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n4p386   Considering biomechanical aspects such as kinematics, fatigue can be characterized as a loss of efficiency in maintaining a movement pattern, such as pedaling technique, during exercise. The objective of this preliminary study was to investigate the effects of 1-h exhaustive cycling exercise at intensity of 80% VO2max on pedaling technique. The pedaling technique was evaluated in four skilled mountain-bike cyclists by 2D kinematics. The main hypothesis of this study was that angular changes in response to fatigue would occur mainly in the ankle joint. After achievement of maximal oxygen uptake (VO2max, the cyclists were submitted to a submaximal protocol at intensity corresponding to 80% VO2max for 1 h. The cyclists were filmed throughout 10 complete consecutive crank cycles at intervals of 10 min. Images were acquired from the right lower limb and the hip, knee and ankle joint angles were measured after kinematic processing. The Shapiro-Wilk test, ANOVA and post-hoc Tukey HSD test were used for statistical analysis, with the level of significance set at 0.05. Statistical analysis showed a significant difference only for ankle kinematics after 40 min of exercise, with an increase in the range of motion from 20° at the beginning of exercise to 35° at the end of exercise. This result confirms the hypothesis proposed and suggests that only the ankle joint was affected by the exercise. The characteristics of ankle movement suggest that this joint plays a compensatory role in an attempt to maintain the pedaling technique and to sustain the exercise workload.

  4. Preliminary studies of epoxidized palm oil as sizing chemical for carbon fibers

    International Nuclear Information System (INIS)

    Salleh, S.N.M.; Ubaidillah, E.A.E.; Abidin, M.F.Z.

    2010-01-01

    Epoxidized palm oil is derived from palm oil through chemical reaction with peracetic acid. Preliminary studies to coat carbon fibers have shown promising result towards applying natural product in carbon fibre composites. Mechanical studies of sized carbon fibers with epoxidized palm oil showed significant increase in tensile and interfacial shear strength. Surface morphology of sized or coated carbon fibers with epoxidized palm oil reveals clear increase in root means square-roughness (RMS). This indicates the change of the surface topography due to sized or coated carbon fibers with epoxidized palm oil. (author)

  5. The preliminary study of the quench protection of an MgB2

    Science.gov (United States)

    Juster, F. P.; Berriaud, C.; Bonelli, A.; Pasquet, R.; Przybilski, H.; Schild, T.; Scola, L.

    2014-01-01

    In the framework of general studies currently carried out at CEA/Saclay in collaboration with Sigmaphi Company on dry MgB2 magnet operating at 10 K and medium range field, 1 T up to 4 T., we plan to build a prototype-coil with a commercial MgB2 wire. This coil, the nominal axial magnetic field of which is 1 tesla, will be placed in a 3 teslas background field generated by a classical NbTi coil. This paper deals with the preliminary quench protection studies including stability and quench propagation modeling.

  6. Possession experiences in dissociative identity disorder: a preliminary study.

    Science.gov (United States)

    Ross, Colin A

    2011-01-01

    Dissociative trance disorder, which includes possession experiences, was introduced as a provisional diagnosis requiring further study in the Diagnostic and Statistical Manual of Mental Disorders (4th ed.). Consideration is now being given to including possession experiences within dissociative identity disorder (DID) in the Diagnostic and Statistical Manual of Mental Disorders (5th ed.), which is due to be published in 2013. In order to provide empirical data relevant to the relationship between DID and possession states, I analyzed data on the prevalence of trance, possession states, sleepwalking, and paranormal experiences in 3 large samples: patients with DID from North America; psychiatric outpatients from Shanghai, China; and a general population sample from Winnipeg, Canada. Trance, sleepwalking, paranormal, and possession experiences were much more common in the DID patients than in the 2 comparison samples. The study is preliminary and exploratory in nature because the samples were not matched in any way.

  7. Radiological follow-up of uncemented knee prostheses. Preliminary study

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gomez Barrena, E.; Marquez Moreno, I.; Calle Yuste, F.; Ordonez Parra, J.M.

    1993-01-01

    The preliminary results of a prospective study of 40 uncemented total knee prostheses (TKP) are presented following a radiological protocol with fluoroscopic control and follow-up of over 2 years. The prosthesis-bone interface and the components alignment were assessed. Several radiological signs were studied to assess this interface with respect to the fixing of the component, but they showed little clinical correlation. Statistical significance (p<0.05, chisquare) was found only in the observation of sclerosis in areas of support for the tibital tray as a reaction of the bone. This radiological follow-up is of interest to determine the evolution of the interface and position of the implant to prevent complications (especially loosening) in patients, particularly those under 60 years old, who represent the group that can most benefit from prosthetic systems with uncemented anchorage because of their life expectation and level of activity. Author

  8. Preliminary Study of RFID System for the LILW Transportation

    International Nuclear Information System (INIS)

    Kim, Dohyung; Lee, Unjang; Choi, Kyusup

    2008-01-01

    Radio-Frequency Identification (RFID) is an automatic identification method, relying on storing and remotely retrieving data using devices called RFID tags or transponders. In Korea, Low-to-Intermediate Level Radioactive Wastes (LILW) are planed to be disposed at Kyeonju disposal repository, and 100,000 LILW drums will be disposed for the first 10 years of disposal. Tracking of these LILW drums is one of the important parts for safe transportation. To track the LILW drums during the transport as well as storage and disposal, RFID can be the prospective method for tracking the LILW drums. In this report, RFID system is introduced to the LILW transport from the generation site to disposal site, and one possible RFID system is suggested as a preliminary study

  9. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  10. Robot assisted navigated drilling for percutaneous pedicle screw placement: A preliminary animal study

    Directory of Open Access Journals (Sweden)

    Hongwei Wang

    2015-01-01

    Conclusions: The preliminary study supports the view that computer assisted pedicle screw fixation using spinal robot is feasible and the robot can decrease the intraoperative fluoroscopy time during the minimally invasive pedicle screw fixation surgery. As spine robotic surgery is still in its infancy, further research in this field is worthwhile especially the accuracy of spine robot system should be improved.

  11. A device for multimodal imaging of skin

    Science.gov (United States)

    Spigulis, Janis; Garancis, Valerijs; Rubins, Uldis; Zaharans, Eriks; Zaharans, Janis; Elste, Liene

    2013-03-01

    A compact prototype device for diagnostic imaging of skin has been developed and tested. Polarized LED light at several spectral regions is used for illumination, and round skin spot of diameter 30mm is imaged by a CMOS sensor via crossoriented polarizing filter. Four consecutive imaging series are performed: (1) RGB image at white LED illumination for revealing subcutaneous structures; (2) four spectral images at narrowband LED illumination (450nm, 540nm, 660nm, 940nm) for mapping of the main skin chromophores; (3) video-imaging under green LED illumination for mapping of skin blood perfusion; (4) autofluorescence video-imaging under UV (365nm) LED irradiation for mapping of the skin fluorophores. Design details of the device as well as preliminary results of clinical tests are presented.

  12. Magnetic resonance elastography in normal human brain: preliminary study

    International Nuclear Information System (INIS)

    Xu Lei; Gao Peiyi; Lin Yan; Han Jiancheng; Xi Zhinong; Shen Hao

    2007-01-01

    Objective: To study the application of magnetic resonance elastography (MRE) in the human brain. Methods: An external force actuator was developed. The actuator was fixed to the head coil. During MRE scan, one side of the actuator was attached to the volunteers' head. Low frequency oscillation was produced by the actuator and generated shear waves propagating into brain tissue. The pulse sequence of MRE was designed. A modified gradient echo sequence was developed with motion sensitizing gradient (MSG) imposed along X, Y or Z direction. Cyclic displacement within brain tissue induced by shear waves caused a measurable phase shift in the received MR signal. From the measured phase shift, the displacement at each voxel could be calculated, and the shear waves within the brain were directly imaged. By adjusting the phase offset, the dynamic propagation of shear waves in a wave cycle was obtained. Phase images were processed with local frequency estimation (LFE) technique to obtain the elasticity images. Shear waves at 100 Hz, 150 Hz, and 200 Hz were applied. Results: The phase images of MRE directly imaged the propagating shear waves within the brain. The direction of the propagation was from surface of the brain to the center. The wavelength of shear waves varied with the change of actuating frequency. The change of wavelength of shear waves in gray and white matter of the brain was identified. The wavelength of shear waves in gray matter was shorter than that in white matter. The elasticity image of the brain revealed that the shear modulus of the white matter was higher than that of gray matter. Conclusion: The phase images of MRE can directly visualize the propagation of shear waves in the brain tissue. The elasticity image of the brain can demonstrate the change of elasticity between gray and white matter. (authors)

  13. Preliminary Understanding of Surface Plasmon-Enhanced Circular Dichroism Spectroscopy by Single Particle Imaging

    Science.gov (United States)

    Zhan, Kangshu

    Monitoring chiral optical signals of biomolecules as their conformation changes is an important means to study their structures, properties, and functions. Most measurements, however, are ensemble measurements because chiral optical signals from a single biomolecule is often too weak to be detected. In this dissertation, I present my early attempts to study conformational changes of adsorbed proteins by taking advantage of the enhanced electromagnetic (EM) field around a well-designed plasmonic nanofeature. In particular, I discuss the detection of protein adsorption and denaturation on metallic nanoparticles using single particle scattering and CD spectroscopic imaging. Particles of two distinctively different sizes were compared and two different sample protein molecules were studied. A combination of experimental and computational tools was used to simulate and interpret the collected scattering and CD results. The first chapter provides a brief overview of the state-of-art research in CD spectroscopic studies at the single particle level. Three different means to make particles capable of chiral detection are discussed. Various applications beyond single particle imaging are presented to showcase the potential of the described research project, beyond our immediate goals. The second chapter describes my initial characterization of large, metallic, anisotropic nanorods and the establishment of experimental procedures used later for spectrum reconstruction, data visualization and analysis. The physical shape and structure of the particles were imaged by scanning electron microscopy (SEM), the chemical composition by energy dispersive X-ray Spectroscopy (EDS), and the optical properties by darkfield microscopy. An experimental protocol was developed to connect information collected from separate techniques for the same particle, with the aims of discovering any possible structural-property correlation. The reproducibility of the single particle imaging method was

  14. Preliminary results of a feasibility study for a hard x-ray Kirkpatrick-Baez telescope

    DEFF Research Database (Denmark)

    Joensen, Karsten D.; Gorenstein, Paul; Wood, James L.

    1994-01-01

    the preliminary results of a feasibility study of a multifocus Kirkpatrick-Baez telescope. We conclude that high quality multilayers can be performed on relevant thin large flat substrate with adequate uniformity, and that existing deposition chambers can produce the multilayers at a rate of 0.42 m2 per day, so...

  15. Determination of the Earth's Plasmapause Location from the CE-3 EUVC Images

    Science.gov (United States)

    He, Fei; Zhang, Xiao-Xin; Chen, Bo; Fok, Mei-Ching; Nakano, Shinya

    2016-01-01

    The Moon-based Extreme Ultraviolet Camera (EUVC) aboard China's Chang'e-3 (CE-3) mission has successfully imaged the entire Earth's plasmasphere for the first time from the side views on lunar surface. An EUVC image on 21 April 2014 is used in this study to demonstrate the characteristics and configurations of the Moon-based EUV imaging and to illustrate the determination algorithm of the plasmapause locations on the magnetic equator. The plasmapause locations determined from all the available EUVC images with the Minimum L Algorithm are quantitatively compared with those extracted from insitu observations (Defense Meteorological Satellite Program, Time History of Events and Macroscale Interactions during Substorms, and Radiation Belt Storm Probes). Excellent agreement between the determined plasmapauses seen by EUVC and the extracted ones from other satellites indicates the reliability of the Moon-based EUVC images as well as the determination algorithm. This preliminary study provides an important basis for future investigation of the dynamics of the plasmasphere with the Moon-based EUVC imaging.

  16. Assessing Internet addiction using the parsimonious Internet addiction components model - a preliminary study [forthcoming

    OpenAIRE

    Kuss, DJ; Shorter, GW; Van Rooij, AJ; Griffiths, MD; Schoenmakers, T

    2014-01-01

    Internet usage has grown exponentially over the last decade. Research indicates that excessive Internet use can lead to symptoms associated with addiction. To date, assessment of potential Internet addiction has varied regarding populations studied and instruments used, making reliable prevalence estimations difficult. To overcome the present problems a preliminary study was conducted testing a parsimonious Internet addiction components model based on Griffiths’ addiction components (2005), i...

  17. A Planar-Fluorescence Imaging Technique for Studying Droplet-Turbulence Interactions in Vaporizing Sprays

    Science.gov (United States)

    Santavicca, Dom A.; Coy, E.

    1990-01-01

    Droplet turbulence interactions directly affect the vaporization and dispersion of droplets in liquid sprays and therefore play a major role in fuel oxidizer mixing in liquid fueled combustion systems. Proper characterization of droplet turbulence interactions in vaporizing sprays require measurement of droplet size velocity and size temperature correlations. A planar, fluorescence imaging technique is described which is being developed for simultaneously measuring the size, velocity, and temperature of individual droplets in vaporizing sprays. Preliminary droplet size velocity correlation measurements made with this technique are presented. These measurements are also compared to and show very good agreement with measurements made in the same spray using a phase Doppler particle analyzer.

  18. The preliminary results: Internal seismic velocity structure imaging beneath Mount Lokon

    Energy Technology Data Exchange (ETDEWEB)

    Firmansyah, Rizky, E-mail: rizkyfirmansyah@hotmail.com [Geophysical Engineering, Faculty of Mining and Petroleum Engineering, Institut Teknologi Bandung, Bandung, 40132 (Indonesia); Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id [Global Geophysical Group, Faculty of Mining and Petroleum Engineering, Institut Teknologi Bandung, Bandung, 40132 (Indonesia); Kristianto, E-mail: kris@vsi.esdm.go.id [Center for Volcanology and Geological Hazard Mitigation (CVGHM), Geological Agency, Bandung, 40122 (Indonesia)

    2015-04-24

    Historical records that before the 17{sup th} century, Mount Lokon had been dormant for approximately 400 years. In the years between 1350 and 1400, eruption ever recorded in Empung, came from Mount Lokon’s central crater. Subsequently, in 1750 to 1800, Mount Lokon continued to erupt again and caused soil damage and fall victim. After 1949, Mount Lokon dramatically increased in its frequency: the eruption interval varies between 1 – 5 years, with an average interval of 3 years and a rest interval ranged from 8 – 64 years. Then, on June 26{sup th}, 2011, standby alert set by the Center for Volcanology and Geological Hazard Mitigation. Peak activity happened on July 4{sup th}, 2011 that Mount Lokon erupted continuously until August 28{sup th}, 2011. In this study, we carefully analyzed micro-earthquakes waveform and determined hypocenter location of those events. We then conducted travel time seismic tomographic inversion using SIMULPS12 method to detemine Vp, Vs and Vp/Vs ratio structures beneath Lokon volcano in order to enhance our subsurface geological structure. During the tomographic inversion, we started from 1-D seismic velocities model obtained from VELEST33 method. Our preliminary results show low Vp, low Vs, and high Vp/Vs are observed beneath Mount Lokon-Empung which are may be associated with weak zone or hot material zones. However, in this study we used few station for recording of micro-earthquake events. So, we suggest in the future tomography study, the adding of some seismometers in order to improve ray coverage in the region is profoundly justified.

  19. A feasibility study of NIR fluorescent image-guided surgery in head and neck cancer based on the assessment of optimum surgical time as revealed through dynamic imaging

    Directory of Open Access Journals (Sweden)

    Yokoyama J

    2013-04-01

    Full Text Available Junkichi Yokoyama,* Mitsuhisa Fujimaki,* Shinichi Ohba, Takashi Anzai, Ryota Yoshii, Shin Ito, Masataka Kojima, Katsuhisa IkedaDepartment of Otolaryngology-Head and Neck Surgery, Juntendo University School of Medicine, Tokyo, Japan *These authors contributed equally to this study Background: In order to minimize surgical stress and preserve organs, endoscopic or robotic surgery is often performed when conducting head and neck surgery. However, it is impossible to physically touch tumors or to observe diffusely invaded deep organs through the procedure of endoscopic or robotic surgery. In order to visualize and safely resect tumors even in these cases, we propose using an indocyanine green (ICG fluorescence method for navigation surgery in head and neck cancer. Objective: To determine the optimum surgical time for tumor resection after the administration of ICG based on the investigation of dynamic ICG fluorescence imaging. Methods: Nine patients underwent dynamic ICG fluorescence imaging for 360 minutes, assessing tumor visibility at 10, 30, 60, 120, 180, and 360 minutes. All cases were scored according to near-infrared (NIR fluorescence imaging visibility scored from 0 to 5. Results: Dynamic NIR fluorescence imaging under the HyperEye Medical System indicated that the greatest contrast in fluorescent images between tumor and normal tissue could be observed from 30 minutes to 1 hour after the administration of ICG. The optimum surgical time was determined to be between 30 minutes to 2 hours after ICG injection. These findings are particularly useful for detection and safe resection of tumors invading the parapharyngeal space. Conclusion: ICG fluorescence imaging is effective for the detection of head and neck cancer. Preliminary findings suggest that the optimum timing for surgery is from 30 minutes to 2 hours after the ICG injection. Keywords: indocyanine green (ICG, navigation surgery, robotic surgery, endoscopic surgery, minimally invasive

  20. Preliminary study on enhancing waste management best practice model in Malaysia construction industry

    Science.gov (United States)

    Jamaludin, Amril Hadri; Karim, Nurulzatushima Abdul; Noor, Raja Nor Husna Raja Mohd; Othman, Nurulhidayah; Malik, Sulaiman Abdul

    2017-08-01

    Construction waste management (CWM) is the practice of minimizing and diverting construction waste, demolition debris, and land-clearing debris from disposal and redirecting recyclable resources back into the construction process. Best practice model means best choice from the collection of other practices that was built for purpose of construction waste management. The practice model can help the contractors in minimizing waste before the construction activities will be started. The importance of minimizing wastage will have direct impact on time, cost and quality of a construction project. This paper is focusing on the preliminary study to determine the factors of waste generation in the construction sites and identify the effectiveness of existing construction waste management practice conducted in Malaysia. The paper will also include the preliminary works of planned research location, data collection method, and analysis to be done by using the Analytical Hierarchy Process (AHP) to help in developing suitable waste management best practice model that can be used in the country.

  1. NICE guidelines for imaging studies in children with UTI adequate only in boys under the age of 6 months.

    Science.gov (United States)

    Ristola, Marko Tapani; Hurme, Timo

    2013-03-01

    The purpose of this study was to evaluate the applicability of the National Institute for Health and Clinical Excellence (NICE) guidelines for imaging studies in children under the age of three with first urinary tract infection (UTI). In our cohort of 112 patients, we gathered data regarding the occurrence of indications for ultrasonography (US) and voiding cystourethrography (VCUG) according to the NICE guidelines, dimercaptosuccinic acid (DMSA) scintigraphy examinations, UTI recurrence, antimicrobial prophylaxis (AMP), anti-reflux procedures, and other urological procedures. If the NICE guidelines had been applied, 13 of the 25 patients (52 %) with vesicoureteral reflux (VUR), including 6 of the 12 patients (50 %) with dilating VUR and 3 of the 4 patients who underwent endoscopic anti-reflux treatment, would have been missed, and a negative VCUG would have been avoided in 25 of the 42 patients (60 %) with no VUR. None of the missed diagnoses occurred in the younger boys' group. Based on these preliminary analyses, we feel that the NICE guidelines for imaging studies in children under 3 years old with UTI may be applicable to clinical use only in boys under 6 months of age. For other patients the guidelines were unsuccessful.

  2. Co-opting Science: A preliminary study of how students invoke science in value-laden discussions

    DEFF Research Database (Denmark)

    Nielsen, J. A.

    2012-01-01

    '. As a preliminary step, this study investigated how Danish upper secondary biology students actually interwove science facts and values in socio-scientific discussions. In particular, the focus was the argumentative effects of different ways of blurring the fact-value distinction. The data consisted...

  3. Weldon Spring, Missouri, Raffinate Pits 1, 2, 3, and 4: Preliminary grout development screening studies for in situ waste immobilization

    International Nuclear Information System (INIS)

    McDaniel, E.W.; Gilliam, T.M.; Dole, L.R.; West, G.A.

    1987-04-01

    Results of Oak Ridge National Laboratory's initial support program to develop a preliminary grout formula to solidify in situ the Weldon Spring waste are presented. The screening study developed preliminary formulas based on a simulated composite waste and then tested the formulas on actual waste samples. Future data needs are also discussed. 1 ref., 6 figs., 9 tabs

  4. Image denoising by exploring external and internal correlations.

    Science.gov (United States)

    Yue, Huanjing; Sun, Xiaoyan; Yang, Jingyu; Wu, Feng

    2015-06-01

    Single image denoising suffers from limited data collection within a noisy image. In this paper, we propose a novel image denoising scheme, which explores both internal and external correlations with the help of web images. For each noisy patch, we build internal and external data cubes by finding similar patches from the noisy and web images, respectively. We then propose reducing noise by a two-stage strategy using different filtering approaches. In the first stage, since the noisy patch may lead to inaccurate patch selection, we propose a graph based optimization method to improve patch matching accuracy in external denoising. The internal denoising is frequency truncation on internal cubes. By combining the internal and external denoising patches, we obtain a preliminary denoising result. In the second stage, we propose reducing noise by filtering of external and internal cubes, respectively, on transform domain. In this stage, the preliminary denoising result not only enhances the patch matching accuracy but also provides reliable estimates of filtering parameters. The final denoising image is obtained by fusing the external and internal filtering results. Experimental results show that our method constantly outperforms state-of-the-art denoising schemes in both subjective and objective quality measurements, e.g., it achieves >2 dB gain compared with BM3D at a wide range of noise levels.

  5. Multimodal Navigation in Endoscopic Transsphenoidal Resection of Pituitary Tumors Using Image-Based Vascular and Cranial Nerve Segmentation: A Prospective Validation Study.

    Science.gov (United States)

    Dolati, Parviz; Eichberg, Daniel; Golby, Alexandra; Zamani, Amir; Laws, Edward

    2016-11-01

    Transsphenoidal surgery (TSS) is the most common approach for the treatment of pituitary tumors. However, misdirection, vascular damage, intraoperative cerebrospinal fluid leakage, and optic nerve injuries are all well-known complications, and the risk of adverse events is more likely in less-experienced hands. This prospective study was conducted to validate the accuracy of image-based segmentation coupled with neuronavigation in localizing neurovascular structures during TSS. Twenty-five patients with a pituitary tumor underwent preoperative 3-T magnetic resonance imaging (MRI), and MRI images loaded into the navigation platform were used for segmentation and preoperative planning. After patient registration and subsequent surgical exposure, each segmented neural or vascular element was validated by manual placement of the navigation probe or Doppler probe on or as close as possible to the target. Preoperative segmentation of the internal carotid artery and cavernous sinus matched with the intraoperative endoscopic and micro-Doppler findings in all cases. Excellent correspondence between image-based segmentation and the endoscopic view was also evident at the surface of the tumor and at the tumor-normal gland interfaces. Image guidance assisted the surgeons in localizing the optic nerve and chiasm in 64% of cases. The mean accuracy of the measurements was 1.20 ± 0.21 mm. Image-based preoperative vascular and neural element segmentation, especially with 3-dimensional reconstruction, is highly informative preoperatively and potentially could assist less-experienced neurosurgeons in preventing vascular and neural injury during TSS. In addition, the accuracy found in this study is comparable to previously reported neuronavigation measurements. This preliminary study is encouraging for future prospective intraoperative validation with larger numbers of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Preliminary Context Analysis of Community Informatics Social ...

    African Journals Online (AJOL)

    Preliminary context analysis is always part of the feasibility study phase in the development of information system for Community Development (CD) purposes. In this paper, a context model and a preliminary context analysis are presented for Social Network Web Application (SNWA) for CD in the Niger Delta region of ...

  7. Nuclear magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Knaap, M.S. van der; Valk, J.

    1989-01-01

    In this article a review is given of the use of magnetic resonance imaging for the central nervous system. An example of the screening of the population for multiple scelerosis is given. A good preliminary examination and the supply of relevant information to the person which performs the imaging is necessary. (R.B.). 9 figs.; 4 tabs

  8. Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, B. J., E-mail: peterson@LHD.nifs.ac.jp; Mukai, K. [National Institute for Fusion Science, Toki 509-5292 (Japan); SOKENDAI (The Graduate University for Advance Studies), Toki 509-5292 (Japan); Sano, R. [National Institutes for Quantum and Radiological Science and Technology, Naka, Ibaraki 311-0193 (Japan); Reinke, M. L.; Canik, J. M.; Lore, J. D.; Gray, T. K. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Delgado-Aparicio, L. F.; Jaworski, M. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Eden, G. G. van [FOM Institute DIFFER, 5612 AJ Eindhoven (Netherlands)

    2016-11-15

    The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.

  9. Microangiographic study of the canine dental tissues: a preliminary report

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.

    1987-01-01

    A microangiographic study of the dental tissues was performed on one adult mongrel dog to examine the usefulness of the technique. This preliminary study used 30% wt/vol Micropaque suspension which was perfused into the common carotid arteries. After the complete perfusion, the specimen was fixed into a mixture of 10% buffered neutral formalin solution and 95% ethyl alcohol. The mandibular bone with teeth in situ was decalcified. The specimen was embedded in methyl methacrylate. One mm slab sections were made, and then the microangiographs were made. Adequate filling of arterioles was evident on the microangiographs. This technique is shown to be useful in characterizing the nature of the blood supply to the bone and teeth that might be involved in the pathogenesis of radiation-induced injury in the canine dental and periodontal tissues

  10. Evaluation of Liver Stiffness After Radioembolization by Real-Time ShearWave™ Elastography: Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Bas, Ahmet, E-mail: dr.ahmetbas@hotmail.com [Istanbul University, Department of Interventional Radiology, Cerrahpasa Faculty of Medicine (Turkey); Samanci, Cesur, E-mail: cesursamanci@gmail.com [Istanbul University, Department of Radiology, Cerrahpasa Faculty of Medicine (Turkey); Gulsen, Fatih, E-mail: drfgulsen@yahoo.com; Cantasdemir, Murat, E-mail: cantasdemir@yahoo.com [Istanbul University, Department of Interventional Radiology, Cerrahpasa Faculty of Medicine (Turkey); Kabasakal, Levent, E-mail: lkabasakal@tsnm.org [Istanbul University, Department of Nuclear Medicine, Cerrahpasa Faculty of Medicine (Turkey); Kantarci, Fatih, E-mail: fatihkan@yahoo.com [Istanbul University, Department of Radiology, Cerrahpasa Faculty of Medicine (Turkey); Numan, Furuzan, E-mail: f.numan@superonline.com [Istanbul University, Department of Interventional Radiology, Cerrahpasa Faculty of Medicine (Turkey)

    2015-08-15

    PurposeTo evaluate the effect of ShearWave™ elastography (SWE) for the assessment of liver fibrosis after radioembolization (RE) in patients with liver malignancies.Materials and MethodsWe prospectively examined the effects of SWE before and after RE in 17 adult patients, from June 2012 to September 2013. All patients underwent SWE within 1 month before and 3 months (96.3 ± 22.9 days) after RE. Measurements were taken in segments III, IV, V, and VI (lateral/medial left lobe and anterior/posterior right lobe, respectively). Liver stiffness was studied in the 39 treated segments.ResultsThe mean stiffness of liver tissue according to the pre-RE SWE measurements was not different from the post-RE SWE measurements in the segments that did not undergo RE. Conversely, segments treated with RE were significantly stiffer according to the post-RE SWE measurements (mean SWE 17.4 kPa) than according to the baseline measurements (7.0 kPa) (p < 0.001). Patients with hepatocellular carcinoma and preexisting infection with hepatitis B and C viruses had higher pre-embolization stiffness, and the post-embolization stiffness of the treated segments in these patients was higher than that in the remainder of the study population.ConclusionThese data suggest that SWE measurements of liver stiffness increase as early as the third month after RE. SWE could be used as a noninvasive complementary imaging method for preliminary assessment of liver fibrosis before and after RE.

  11. A preliminary study on titanium-clay interactions

    International Nuclear Information System (INIS)

    Wersin, P.; Grolimund, D.; Kumpulainen, S.; Brendle, J.; Snellman, M.

    2010-01-01

    bentonite, Opalinus Clay, Illite du Puy) were characterized by XAS. Preliminary results can be summarized as: (1) Natural clay materials contain significant but variable amounts of Ti. The standard purification procedure for bentonites to remove accessories does not or only barely removes Ti. (2) The Ti in the natural clays materials Rokle bentonite, Opalinus Clay, Illite du Puy occurs as microcrystalline TiO 2 (presumably as anatase). On the other hand, the Ti spectra in MX-80 suggest the presence of structural Ti in the smectite, but the evidence is not conclusive so far. (3) The exposure of purified MX-80 to titanium powder at room temperature within a period of five months did not lead to measurable additional Ti in the clay. This was even true for samples exposed to acidic or alkaline conditions where corrosion rates and solubility of Ti are known to be higher. Thereof, the following preliminary conclusions can be drawn: - The Ti content in natural bentonites is concentrated mainly in the so-called clay fraction. Ti occurs therein either as separate small TiO 2 particles (Rokle, Opalinus Clay, Illite du Puy) or as structural Ti. As indicated by the study of Karnland et al. (2006), the properties of natural bentonites are not affected by the presence of Ti. In that study, the bulk properties (swelling pressure, hydraulic conductivity) were very similar for the different bentonites containing variable Ti content, ranging from 0.1 to 4.8 weight % TiO 2 in the purified clay fractions. The transfer rates of Ti from the metallic source, even in reactive powder form, to the clay are very low and no enrichment above background concentrations after several months could be observed. In order to obtain measurable effects, both the corrosion process must be increased and the background concentration must be reduced. Tests with Ti-free clay material at increased temperature are still ongoing and will hopefully enable identification of reacted Ti species. (authors)

  12. Application of deep learning to the classification of images from colposcopy.

    Science.gov (United States)

    Sato, Masakazu; Horie, Koji; Hara, Aki; Miyamoto, Yuichiro; Kurihara, Kazuko; Tomio, Kensuke; Yokota, Harushige

    2018-03-01

    The objective of the present study was to investigate whether deep learning could be applied successfully to the classification of images from colposcopy. For this purpose, a total of 158 patients who underwent conization were enrolled, and medical records and data from the gynecological oncology database were retrospectively reviewed. Deep learning was performed with the Keras neural network and TensorFlow libraries. Using preoperative images from colposcopy as the input data and deep learning technology, the patients were classified into three groups [severe dysplasia, carcinoma in situ (CIS) and invasive cancer (IC)]. A total of 485 images were obtained for the analysis, of which 142 images were of severe dysplasia (2.9 images/patient), 257 were of CIS (3.3 images/patient), and 86 were of IC (4.1 images/patient). Of these, 233 images were captured with a green filter, and the remaining 252 were captured without a green filter. Following the application of L2 regularization, L1 regularization, dropout and data augmentation, the accuracy of the validation dataset was ~50%. Although the present study is preliminary, the results indicated that deep learning may be applied to classify colposcopy images.

  13. Preliminary study of the thermo-hydraulic behaviour of the binary breeder reactor

    International Nuclear Information System (INIS)

    Silveira Luz, M. da; Ferreira, W.J.

    1984-06-01

    Continuing the development of the Binary Breeder Reactor, its physical configuration and the advantages of differents types of spacers are analysed. In order to simulate the thermo-hydraulic behaviour and obtain data for a preliminary evaluation of the core geometry, the COBRA III C code was used to study the effects of the lenght and diameter of the fuel element, the coolant inlet temperature, the system pressure, helicoidal pitch and the pitch to diameter ratio. (Author) [pt

  14. Partitioning planning studies: Preliminary evaluation of metal and radionuclide partitioning the high-temperature thermal treatment systems

    International Nuclear Information System (INIS)

    Liekhus, K.; Grandy, J.; Chambers, A.

    1997-03-01

    A preliminary study of toxic metals and radionuclide partitioning during high-temperature processing of mixed waste has been conducted during Fiscal Year 1996 within the Environmental Management Technology Evaluation Project. The study included: (a) identification of relevant partitioning mechanisms that cause feed material to be distributed between the solid, molten, and gas phases within a thermal treatment system; (b) evaluations of existing test data from applicable demonstration test programs as a means to identify and understand elemental and species partitioning; and, (c) evaluation of theoretical or empirical partitioning models for use in predicting elemental or species partitioning in a thermal treatment system. This preliminary study was conducted to identify the need for and the viability of developing the tools capable of describing and predicting toxic metals and radionuclide partitioning in the most applicable mixed waste thermal treatment processes. This document presents the results and recommendations resulting from this study that may serve as an impetus for developing and implementing these predictive tools

  15. Partitioning planning studies: Preliminary evaluation of metal and radionuclide partitioning the high-temperature thermal treatment systems

    Energy Technology Data Exchange (ETDEWEB)

    Liekhus, K.; Grandy, J.; Chambers, A. [and others

    1997-03-01

    A preliminary study of toxic metals and radionuclide partitioning during high-temperature processing of mixed waste has been conducted during Fiscal Year 1996 within the Environmental Management Technology Evaluation Project. The study included: (a) identification of relevant partitioning mechanisms that cause feed material to be distributed between the solid, molten, and gas phases within a thermal treatment system; (b) evaluations of existing test data from applicable demonstration test programs as a means to identify and understand elemental and species partitioning; and, (c) evaluation of theoretical or empirical partitioning models for use in predicting elemental or species partitioning in a thermal treatment system. This preliminary study was conducted to identify the need for and the viability of developing the tools capable of describing and predicting toxic metals and radionuclide partitioning in the most applicable mixed waste thermal treatment processes. This document presents the results and recommendations resulting from this study that may serve as an impetus for developing and implementing these predictive tools.

  16. Preliminary Study of 20 MWth Experiment Power Reactor based on Pebble Bed Reactor

    Science.gov (United States)

    Irwanto, Dwi; Permana, Sidik; Pramuditya, Syeilendra

    2017-07-01

    In this study, preliminary design calculations for experimental small power reactor (20 MWt) based on Pebble Bed Reactor (PBR) are performed. PBR technology chosen due to its advantages in neutronic and safety aspects. Several important parameters, such as fissile enrichment, number of fuel passes, burnup and effective multiplication factor are taken into account in the calculation to find neutronic characteristics of the present reactor design.

  17. Reliability of the Filipino version of the Parent Satisfaction Scale: A preliminary study

    OpenAIRE

    Palad, Yves Y.; Madriaga, Gilbert O.

    2014-01-01

    Parent satisfaction is vital in improving the delivery of paediatric health care. However, there are no linguistically appropriate instruments that measure parent satisfaction among Filipino parents of children receiving occupational therapy, physical therapy, and speech pathology services. This study aimed to provide preliminary information about the reliability of the Filipino version of the Parent Satisfaction Scale (F-PSS). Research procedures included forward- and backward-translation of...

  18. Preliminary results from a study of the double beta decay of 150Nd

    International Nuclear Information System (INIS)

    Perillo, I.M.C.; Chan, Y.D.; Hurley, D.; Lesko, K.T.; McDonald, R.J.; Moorhead, M.E.; Norman, E.B.; Smith, A.R.; Stokstad, R.G.

    1996-01-01

    We report the preliminary results from a study of the double beta decay of 150 Nd to the first 0 + excited state of 150 Sm. Our data consists of 50 days of counting 5 kg of natural Nd 2 O 3 at the LBNL-Oroville low background facility. The deduced lower limit for the half life of this decay mode is 4.9.10 19 years. (orig.)

  19. Preliminaries on core image analysis using fault drilling samples; Core image kaiseki kotohajime (danso kussaku core kaisekirei)

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, T; Ito, H [Geological Survey of Japan, Tsukuba (Japan)

    1996-05-01

    This paper introduces examples of image data analysis on fault drilling samples. The paper describes the following matters: core samples used in the analysis are those obtained from wells drilled piercing the Nojima fault which has moved in the Hygoken-Nanbu Earthquake; the CORESCAN system made by DMT Corporation, Germany, used in acquiring the image data consists of a CCD camera, a light source and core rotation mechanism, and a personal computer, its resolution being about 5 pixels/mm in both axial and circumferential directions, and 24-bit full color; with respect to the opening fractures in core samples collected by using a constant azimuth coring, it was possible to derive values of the opening width, inclination angle, and travel from the image data by using a commercially available software for the personal computer; and comparison of this core image with the BHTV record and the hydrophone VSP record (travel and inclination obtained from the BHTV record agree well with those obtained from the core image). 4 refs., 4 figs.

  20. The near-infrared Tully-Fisher relation - A preliminary study of the Coma and Abell 400 clusters

    Science.gov (United States)

    Guhathakurta, Puragra; Bernstein, Gary; Raychaudhury, Somak; Haynes, Martha; Giovanelli, Riccardo; Herter, Terry; Vogt, Nicole

    1993-01-01

    We have started a large project to study the NIR Tully-Fisher (TF) relation using H- and I-band surface photometry of spiral galaxies. A preliminary study of 20 spirals in the Coma and Abell 400 clusters is presented. The NIR images have been used to derive accurate inclinations and total magnitudes, and rotational linewidths are measured from high-quality 21-cm Arecibo data. The scatter in the Coma TF plot is found to be 0.19 mag in the H band and 0.20 mag in the I band for a set of 13 galaxies, if we assume that they are all at the same distance. The deviation of the Coma galaxies from the best-fit Tully-Fisher relation is correlated with their redshift, indicating that some of the galaxies are not bound to the cluster. Indeed, if we treat all the galaxies in the Coma sample as undergoing free Hubble expansion, the TF scatter drops to 0.12 and 0.13 mag for the H- and I-band datasets, respectively. The Abell 400 sample is best fit by a common distance model, yielding a scatter of 0.12 mag for seven galaxies in H using a fixed TF slope. We are in the process of studying cluster and field spirals out to about 10,000 km/s in order to calibrate the NIR TF relation and will apply it to more nearby galaxies to measure the peculiar velocity field in the local universe.

  1. Crisis Response Strategy and Crisis Types Suitability: A Preliminary Study on MH370

    OpenAIRE

    Mohamad Ashari Noratikah; Abang Ahmad Dayang Aizza Maisha; Samani Mus Chairil

    2017-01-01

    In time of crisis, the organisation’s tactic in responding to the crisis according to its type/s may significantly affect the organisation’s effort to survive its reputational damages. The study of crisis response strategy (CRS) requires further exploration within the Malaysian context, moreso with the greater and apparent use of social media as a platform for the organisation in crisis to reach out to its stakeholders. This preliminary paper studies the MH370 crisis in light of Coombs [1] Si...

  2. Re-thinking the store image study approach

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2001-01-01

    Store image has traditionally been of interest in the Western markets. Studies of store image have also assessed the image of one or a few competing stores. This paper develops an approach to capture store images of an entire retail sector, an issue of importance when enter-ing the new emerging...

  3. Original article The risk of muscle dysmorphia and the perception of change in retrospective, current and ideal self-imagepreliminary study

    Directory of Open Access Journals (Sweden)

    Dorota Mącik

    2014-11-01

    Full Text Available Background A specific type of causes of extended training and gym exercises is muscle dysmorphia. People with this disorder think that their current appearance is not satisfactory, and the focus on the perceived defect is great. The perceived defect usually is connected with body and muscle mass and body shape. According to the conceptual model of dysmorphia proposed by Grieve (2007, the aim of the study was to verify the thesis that the risk of muscle dysmorphia is associated with the negative self-image generalized based on physical appearance. Participants and procedure Twelve women and 18 men, fulfilling the criteria of exercise addiction according to Pope, filled out the ACL scale, answering the questions concerning what kind of person they were before training, who they are now and what kind of person they would like to be. Also, they answered freely the questions concerning their feelings about training. Results A significant difference between perceived retrospective and current self-image was observed. The people examined became, in their opinion, more self-confident, more dominating and independent, and they described themselves in more positive categories. However, there still is relatively a lot of aggression and anxiety. The analysis of the ideal self-image indicates that the presented image performs – at least partly – the defence mechanism role. This is also confirmed by the analysis of the statements of the subjects examined, especially the question about the benefits resulting from the training. Conclusions The results confirm the role of the negative self-image in the risk of muscle dysmorphia. The exercises change self-assessment, but they do not solve the problems that were the reason for it. The characteristics of these problems in further research will facilitate therapy planning.

  4. The cost of child health inequalities in Aotearoa New Zealand: a preliminary scoping study

    Directory of Open Access Journals (Sweden)

    Mills Clair

    2012-05-01

    Full Text Available Abstract Background Health inequalities have been extensively documented, internationally and in New Zealand. The cost of reducing health inequities is often perceived as high; however, recent international studies suggest the cost of “doing nothing” is itself significant. This study aimed to develop a preliminary estimate of the economic cost of health inequities between Māori (indigenous and non-Māori children in New Zealand. Methods Standard quantitative epidemiological methods and “cost of illness” methodology were employed, within a Kaupapa Māori theoretical framework. Data were obtained from national data collections held by the New Zealand Health Information Service and other health sector agencies. Results Preliminary estimates suggest child health inequities between Māori and non-Māori in New Zealand are cost-saving to the health sector. However the societal costs are significant. A conservative “base case” scenario estimate is over $NZ62 million per year, while alternative costing methods yield larger costs of nearly $NZ200 million per annum. The total cost estimate is highly sensitive to the costing method used and Value of Statistical Life applied, as the cost of potentially avoidable deaths of Māori children is the major contributor to this estimate. Conclusions This preliminary study suggests that health sector spending is skewed towards non-Māori children despite evidence of greater Māori need. Persistent child health inequities result in significant societal economic costs. Eliminating child health inequities, particularly in primary care access, could result in significant economic benefits for New Zealand. However, there are conceptual, ethical and methodological challenges in estimating the economic cost of child health inequities. Re-thinking of traditional economic frameworks and development of more appropriate methodologies is required.

  5. Preliminary Study on the High Efficiency Supercritical Pressure Water-Cooled Reactor for Electricity Generation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yoon Yeong; Park, Jong Kyun; Cho, Bong Hyun and others

    2006-01-15

    This research has been performed to introduce a concept of supercritical pressure water cooled reactor(SCWR) in Korea The area of research includes core conceptual design, evaluation of candidate fuel, fluid systems conceptual design with mechanical consideration, preparation of safety analysis code, and construction of supercritical pressure heat transfer test facility, SPHINX, and preliminary test. As a result of the research, a set of tools for the reactor core design has been developed and the conceptual core design with solid moderator was proposed. The direct thermodynamic cycle has been studied to find a optimum design. The safety analysis code has also been adapted to supercritical pressure condition. A supercritical pressure CO2 heat transfer test facility has been constructed and preliminary test proved the facility works as expected. The result of this project will be good basis for the participation in the international collaboration under GIF GEN-IV program and next 5-year mid and long term nuclear research program of MOST. The heat transfer test loop, SPHINX, completed as a result of this project may be used for the power cycle study as well as further heat transfer study for the various geometries.

  6. A phase contrast imaging system for TEXT-U

    International Nuclear Information System (INIS)

    Chatterjee, R.; Hallock, G.A.; Gartman, M.L.

    1994-01-01

    A diagnostic to study plasma density fluctuations, Phase Contrast Imaging (PCI) has been developed for the Texas Experimental Tokamak-Upgrade. The diagnostic has a sensitivity of about 10 -4 n e0 and is capable of detecting a wide range of wavenumbers (0.5 cm -1 - 12 cm -1 ) with a bandwidth of 500 Khz. The design of the diagnostic, some results of acoustic calibration tests and preliminary results of simulation of expected spectra are presented

  7. Tissue characterization using magnetic resonance elastography: preliminary results

    International Nuclear Information System (INIS)

    Kruse, S.A.; Smith, J.A.; Lawrence, A.J.; Dresner, M.A.; Manduca, A.; Greenleaf, J.F.; Ehman, R.L.

    2000-01-01

    The well-documented effectiveness of palpation as a diagnostic technique for detecting cancer and other diseases has provided motivation for developing imaging techniques for non-invasively evaluating the mechanical properties of tissue. A recently described approach for elasticity imaging, using propagating acoustic shear waves and phase-contrast MRI, has been called magnetic resonance elastography (MRE). The purpose of this work was to conduct preliminary studies to define methods for using MRE as a tool for addressing the paucity of quantitative tissue mechanical property data in the literature. Fresh animal liver and kidney tissue specimens were evaluated with MRE at multiple shear wave frequencies. The influence of specimen temperature and orientation on measurements of stiffness was studied in skeletal muscle. The results demonstrated that all of the materials tested (liver, kidney, muscle and tissue-simulating gel) exhibit systematic dependence of shear stiffness on shear rate. These data are consistent with a viscoelastic model of tissue mechanical properties, allowing calculation of two independent tissue properties from multiple-frequency MRE data: shear modulus and shear viscosity. The shear stiffness of tissue can be substantially affected by specimen temperature. The results also demonstrated evidence of shear anisotropy in skeletal muscle but not liver tissue. The measured shear stiffness in skeletal muscle was found to depend on both the direction of propagation and polarization of the shear waves. (author)

  8. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  9. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  10. THE COMPATIBILITY STUDENT CHOICE OF UNIVERSITY MAJORING; A PRELIMINARY STUDIES

    Directory of Open Access Journals (Sweden)

    Daharnis Daharnis

    2016-06-01

    Full Text Available The continuous improvements in order to optimize the basic education to higher education are still running. Based on that purpose, there are many factors to supporting the students' learning activities success; one of the factors is suitability with majors in university. The purpose of this study is to reveal the condition of the compatibility of students majoring with their interest, then to describe the information when the student choose their majoring. Samples in this study were 122 peoples, taken by random sampling from the Padang State University. Data obtained by distributing questionnaires. The results showed that there are students that their major do not match with their interest (22.13%, only 3.28% of students who feel compatible with their major. This result should be a major concern, particularly for counselor in schools for design counseling services to solve these problems. The result of this study used as a grand tour or a preliminary study for further research.

  11. High-resolution flow imaging of the carotid arteries

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Modic, M.T.; Haacke, E.M.; Lenz, G.W.; Ross, J.S.

    1986-01-01

    Recently, high-contrast vascular images have been demonstrated using short TEs, gating and subtraction. However, to obtain short TE values, large gradients are required. This potentially limits the field of view, signal-to-noise- ratio, and resolution. Furthermore, gating in different parts of the cardiac cycle can lead to pixel misregistration. In this study, additional refocusing gradients were applied so that no velocity-dependent dephasing occurs at the echo restoring signal from moving blood. Two cardiac-gated sequences using the same trigger delay and one acquisition were obtained. Preliminary results indicate that good quality vascular images of the carotid bifurcation can be obtained with modifications of the spin-echo technique of with short TEs utilizing a gradient echo technique

  12. El prestigi empresarial: Anàlisi a través de les conselleries creuades The business prestige: A preliminary study based on interlocks within companies The business prestige: A preliminary study based on interlocks within companies

    Directory of Open Access Journals (Sweden)

    David Gonzalez-Prieto

    2011-11-01

    Full Text Available Purpose: The literature on interlocked directorate or interlocks has proposed the presence of cross-directors as an influential factor in the prestige of a firm (Mizruchi, 1996. This theory is based on the fact that, by having multiple companies with interlocks within them, major stakeholders of the company ought to have a higher perception of prestige. The aim of this preliminary study is to present an exploratory study and suggest future research lines on this issue. Design/methodology/approach: In a first preliminary study, we evaluate the interlocks network comprising companies belonging to the ranking established by the MERCO report in Spain for the year 2010. This is a well-known ranking of corporate reputation in Spain used in recent articles (Luna & Fernandez, 2010. For further analysis, other variables are considered as being quoted in the Spanish market benchmark index, IBEX 35, and the location of the headquarters.Findings: Significant positive relationship was obtained between the number of directorships shared with other public companies and the perceived prestige that stakeholders perceive from the firm. Similarly, we obtain significant positive correlation between the prestige and being listed on the IBEX 35. Finally, we identified banking, construction and energy sectors as the ones that use interlocking directorates more intensively.Research limitations: The results of this preliminary study show the viability of future studies about prestige and interlocks (Mizruchi, 1996. For the validation of the theory described in this study, it should be replicated in different regions and, with larger samples, to observe the effect that interlocks have on the perception of prestige of the company.Practical implications / Originality/value: This is among the first studies showing the existence of a relationship between interlocks and business prestige. It highlights the importance of the composition of the boards for the perceived prestige

  13. Preliminary study on detection of irradiated foodstuffs from the Romanian market

    International Nuclear Information System (INIS)

    Cutrubinis, Mihalis; Chirita, Daniel; Savu, Diana; Elisabeta Secu, Corina; Mihai, Radu; Secu, Mihai; Ponta, Corneliu

    2007-01-01

    In order to fulfil the European task for market survey in food irradiation the first Romanian laboratory for detection of irradiated foodstuffs was established at IRASM Irradiation Centre. In this preliminary study, a wide range of Romanian food samples (spices, vegetables and meat) gamma irradiated at IRASM have been studied using different detection methods: (1) DNA comet assay, (2) thermoluminescence (TL) and (3) electron spin resonance (ESR) for foodstuffs containing bone or cellulose. The results suggest that there is no general available detection method and there is no perfect detection method. In conclusion, in order to carry out a correct identification of radiation treatment of a food sample it is recommended to use at least two standardised detection methods

  14. Discriminating Yogurt Microstructure Using Diffuse Reflectance Images

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Møller, Flemming; Abildgaard, Otto Højager Attermann

    2015-01-01

    The protein microstructure of many dairy products is of great importance for the consumers’ experience when eating the product. However, studies concerning discrimination between protein microstructures are limited. This paper presents preliminary results for discriminating different yogurt...... microstructures using hyperspectral (500-900nm) diffuse reflectance images (DRIs) – a technique potentially well suited for inline process control. Comparisons are made to quantified measures of the yogurt microstructure observed through confocal scanning laser microscopy (CSLM). The output signal from both...... modalities is evaluated on a 24 factorial design covering four common production parameters, which significantly change the chemistry and the microstructure of the yogurt. It is found that the DRIs can be as discriminative as the CSLM images in certain cases, however the performance is highly governed...

  15. Dynamic motion analysis of fetuses with central nervous system disorders by cine magnetic resonance imaging using fast imaging employing steady-state acquisition and parallel imaging: a preliminary result.

    Science.gov (United States)

    Guo, Wan-Yuo; Ono, Shigeki; Oi, Shizuo; Shen, Shu-Huei; Wong, Tai-Tong; Chung, Hsiao-Wen; Hung, Jeng-Hsiu

    2006-08-01

    The authors present a novel cine magnetic resonance (MR) imaging, two-dimensional (2D) fast imaging employing steady-state acquisition (FIESTA) technique with parallel imaging. It achieves temporal resolution at less than half a second as well as high spatial resolution cine imaging free of motion artifacts for evaluating the dynamic motion of fetuses in utero. The information obtained is used to predict postnatal outcome. Twenty-five fetuses with anomalies were studied. Ultrasonography demonstrated severe abnormalities in five of the fetuses; the other 20 fetuses constituted a control group. The cine fetal MR imaging demonstrated fetal head, neck, trunk, extremity, and finger as well as swallowing motions. Imaging findings were evaluated and compared in fetuses with major central nervous system (CNS) anomalies in five cases and minor CNS, non-CNS, or no anomalies in 20 cases. Normal motility was observed in the latter group. For fetuses in the former group, those with abnormal motility failed to survive after delivery, whereas those with normal motility survived with functioning preserved. The power deposition of radiofrequency, presented as specific absorption rate (SAR), was calculated. The SAR of FIESTA was approximately 13 times lower than that of conventional MR imaging of fetuses obtained using single-shot fast spin echo sequences. The following conclusions are drawn: 1) Fetal motion is no longer a limitation for prenatal imaging after the implementation of parallel imaging with 2D FIESTA, 2) Cine MR imaging illustrates fetal motion in utero with high clinical reliability, 3) For cases involving major CNS anomalies, cine MR imaging provides information on extremity motility in fetuses and serves as a prognostic indicator of postnatal outcome, and 4) The cine MR used to observe fetal activity is technically 2D and conceptually three-dimensional. It provides four-dimensional information for making proper and timely obstetrical and/or postnatal management

  16. Combined optical and single photon emission imaging: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Boschi, Federico; Calderan, Laura; Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Spinelli, Antonello E [Medical Physics Department, San Raffaele Scientific Institute, Milan (Italy); D' Ambrosio, Daniela; Marengo, Mario [Medical Physics Department, S. Orsola Malpighi Hospital, Bologna (Italy)], E-mail: federico.boschi@univr.it

    2009-12-07

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument. (letter to the editor)

  17. (1'23I)DaTSCAN and SPET imaging of dopamine carrier in Parkinson's disease (preliminary report)

    International Nuclear Information System (INIS)

    Chmielowski, K.; Szalus, N.; Pakszys, W.; Kulinski, W.; Skrobowska, E.

    2003-01-01

    The authors present own experience in dopamine carrier imaging by means of SPET and ( 123I ) DaTSCAN in Parkinson's disease. The aim of study was an assessment of the functional status of presynaptic dopaminergic system. The material consisted of three patients including one with spontaneous tremor and two with Parkinson's disease. The study was conducted according to EANM quidelines. The thyroid was blocked with sodium perchlorate administered orally (400 mg). ( 123I )DaTSCAN was injected intravenously. After three hours cerebral SPET was carried out using Varicam gamma camera. Reconstruction of SPET images was performed by the method of filtered retrograde projection using a Butterworth filter. SPET images of the brain were assessed visually and semiquantitatively through fusion and superimposing of SPET and MRI images together with marked templates (ROIs) for the corpus striatum.The obtained cerebral SPET results in three patients confirmed the diagnosis of spontaneous tremor in one case and Parkinson's disease in the remaining two subject. No adverse effects of ( 123I )DaTSCAN administration were found. Cocaine analogue, (sI)DaTSCAN, is an easy, safe and useful diagnostic test in SPET imaging of dopamine carrier in Parkinson's diseases and in spontaneous tremor. (author)

  18. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  19. Human low vision image warping - Channel matching considerations

    Science.gov (United States)

    Juday, Richard D.; Smith, Alan T.; Loshin, David S.

    1992-01-01

    We are investigating the possibility that a video image may productively be warped prior to presentation to a low vision patient. This could form part of a prosthesis for certain field defects. We have done preliminary quantitative studies on some notions that may be valid in calculating the image warpings. We hope the results will help make best use of time to be spent with human subjects, by guiding the selection of parameters and their range to be investigated. We liken a warping optimization to opening the largest number of spatial channels between the pixels of an input imager and resolution cells in the visual system. Some important effects are not quantified that will require human evaluation, such as local 'squashing' of the image, taken as the ratio of eigenvalues of the Jacobian of the transformation. The results indicate that the method shows quantitative promise. These results have identified some geometric transformations to evaluate further with human subjects.

  20. Processing of space images and geologic interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Yudin, V S

    1981-01-01

    Using data for standard sections, a correlation was established between natural formations in geologic/geophysical dimensions and the form they take in the imaging. With computer processing, important data can be derived from the image. Use of the above correlations has allowed to make a number of preliminary classifications of tectonic structures, and to determine certain ongoing processes in the given section. The derived data may be used for search of useful minerals.