WorldWideScience

Sample records for preliminary experimental tests

  1. Preliminary CFD Assessment of an Experimental Test Facility Operating with Heavy Liquid Metals

    Directory of Open Access Journals (Sweden)

    Matteo Lizzoli

    2017-01-01

    Full Text Available The CFD analysis of a Venturi nozzle operating in LBE (key component of the CIRCE facility, owned by ENEA is presented in this paper. CIRCE is a facility developed to investigate in detail the fluid-dynamic behavior of ADS and/or LFR reactor plants. The initial CFD simulations have been developed hand in hand with the comparison with experimental data: the test results were used to confirm the reliability of the CFD model, which, in turn, was used to improve the interpretation of the experimental data. The Venturi nozzle is modeled with a 3D CFD code (STAR-CCM+. Later on, the CFD model has been used to assess the performance of the component in conditions different from the ones tested in CIRCE: the performance of the Venturi is presented, in terms of pressure drops, for various operating conditions. Finally, the CFD analysis has been focused on the evaluation of the effects of the injection of an inert gas in the flow of the liquid coolant on the performance of the Venturi nozzle.

  2. Construction of PREMUX and preliminary experimental results, as preparation for the HCPB breeder unit mock-up testing

    Energy Technology Data Exchange (ETDEWEB)

    Hernández, F., E-mail: francisco.hernandez@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Kolb, M. [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials (IAM-WPT) (Germany); Annabattula, R. [Indian Institute of Technology Madras (IITM), Department of Mechanical Engineering (India); Weth, A. von der [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany)

    2014-10-15

    Highlights: • PREMUX has been constructed as preparation for a future out-of-pile thermo-mechanical qualification of a HCPB breeder unit mock-up. • The rationale and constructive details of PREMUX are reported in this paper. • PREMUX serves as a test rig for the new heater system developed for the HCPB-BU mock-up. • PREMUX will be used as benchmark for the thermal and thermo-mechanical models developed in ANSYS for the pebble beds of the HCPB-BU. • Preliminary results show the functionality of PREMUX and the good agreement of the measured temperatures with the thermal model developed in ANSYS. - Abstract: One of the European blanket designs for ITER is the Helium Cooled Pebble Bed (HCPB) blanket. The core of the HCPB-TBM consists of so-called breeder units (BUs), which encloses beryllium as neutron multiplier and lithium orthosilicate (Li{sub 4}SiO{sub 4}) as tritium breeder in form of pebble beds. After the design phase of the HCPB-BU, a non-nuclear thermal and thermo-mechanical qualification program for this device is running at the Karlsruhe Institute of Technology. Before the complex full scale BU testing, a pre-test mock-up experiment (PREMUX) has been constructed, which consists of a slice of the BU containing the Li{sub 4}SiO{sub 4} pebble bed. PREMUX is going to be operated under highly ITER-relevant conditions and has the following goals: (1) as a testing rig of new heater concept based on a matrix of wire heaters, (2) as benchmark for the existing finite element method (FEM) codes used for the thermo-mechanical assessment of the Li{sub 4}SiO{sub 4} pebble bed, and (3) in situ measurement of thermal conductivity of the Li{sub 4}SiO{sub 4} pebble bed during the tests. This paper describes the construction of PREMUX, its rationale and the experimental campaign planned with the device. Preliminary results testing the algorithm used for the temperature reconstruction of the pebble bed are reported and compared qualitatively with first analyses

  3. Preliminary experimental results from the ICARUS test facility at INFN-LNL

    Energy Technology Data Exchange (ETDEWEB)

    Varanini, F. [Dept. of Physics and INFN, University of Padova, via Marzolo 8, 35100 Padova (Italy)

    2009-12-15

    A liquid Argon TPC with a sensitive volume of 27 l has been operated with cosmic rays in the INFN-LNL laboratories. This detector is used to test possible DAQ and trigger solutions for ICARUS and future liquid Argon TPCs.

  4. ANALYSIS OF THE FORCE DURING OVERCOMING THE ROADBLOCK – THE PRELIMINARY EXPERIMENTAL TESTS

    Directory of Open Access Journals (Sweden)

    Jakub POLASIK

    2016-03-01

    Full Text Available The paper applies to the issue of preservation of passenger vehicles during overcoming the roadblocks on a dry asphalt surface with the constant speed. The study aimed to estimate the forces which are affecting the suspension of the vehicle during the contact between a tyre and roadblock. Using the video recording it is possible to calculate the values of the tyre deflection and forces acting in the system. The obtained deflections of the tyres were compared to earlier laboratory test results and load-deflection characteristics of the tyres with the same size. The roadblock with the defined geometry causes a dynamic deflection of the tyre. During the study a significant change in the geometry of the suspension has not occurred. The paper presents the characteristics of the vehicles research with a particular regard to model and type of tyres. The determination of the exact dimensions of the roadblocks and application of the ADIS 16385 system for acquisition and archiving the features of the kinematic motion of the vehicle allowed to determine the speed at the moment of collision with the roadblock.

  5. Preliminary experimental results using the thermal-hydraulic integral test facility (VISTA) for the pilot plant of the system integrated modular advanced reactor, SMART-P

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Pak, Hyun Sik; Cho, Seok; Pak, Choon Kyung; Lee, Sung Jae; Song, Chul Hwa; Chung, Moon Ki [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    Preliminary experimental tests were carried out using the thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), which has been constructed to simulate the SMART-P. The VISTA facility is an integral test facility including the primary and secondary systems as well as safety-related Passive Residual heat removal (PRHR) systems. Its scaled ratio with respect to the SMART-P is 1/1 in height and 1/96 in volume and heater power. So far, several steady states and transient tests have been carried out to verify the overall thermal hydraulic primary and secondary characteristics in a range of 10% to 100% power operation. As results of preliminary results, the steady state conditions were found to coincide with the expected design values of the SMART-P. But the major thermal hydraulic parameters are greatly affected by the initial water level and the nitrogen pressure in the reactor upper annular cavity. In the PRHR transient tests, the steam inlet temperature of the PRHR system is found to drop suddenly from a superheated condition to a saturated condition at the end period of PRHR operation.

  6. Thermal Conductivity Measurements By Means of a New `Small Hot-Box' Apparatus: Manufacturing, Calibration and Preliminary Experimental Tests on Different Materials

    Science.gov (United States)

    Buratti, C.; Belloni, E.; Lunghi, L.; Barbanera, M.

    2016-05-01

    The evaluation of the thermal performance building components requires a high level of accuracy. Windows, doors and thermal bridges are not homogeneous, and their thermal transmittance can be evaluated by means of Hot-Box, used for full-scale elements. For homogeneous materials and one-dimensional heat flux, the thermal conductivity can be easily measured through other experimental apparatuses, such as the guarded hot plate and the heat flow meters. This study presents a new experimental apparatus named Small Hot-Box, built at the University of Perugia. No European standards are available for this innovative facility, but it takes into account some prescriptions of EN ISO 8990 and EN ISO 12567; it was built for the evaluation of the thermal properties of small specimens. The apparatus was designed, built, and calibrated by means of preliminary measurements. It is composed of a hot and a cold side, and the external walls are made of thick insulation. The thermal conductivity can be calculated by two different methodologies: the Hot-Box and the thermal flux meter method. Preliminary calibrations were carried out and different materials with known thermal transmittance were tested. The aim is the development of a new experimental apparatus; guidance documents could be defined for the measurements methodology requirements.

  7. Theoretical analyses and numerical simulations of the torsional mode for two acoustic viscometers with preliminary experimental tests.

    Science.gov (United States)

    Ai, Yuhui; Lange, Rebecca A

    2008-03-01

    A rigorous analysis of the torsional modes in both a cylindrical wave guide and the associated static viscous fluid field has been conducted from the solid and the fluid wave equations and the coupled boundary conditions. As a result, two acoustic viscometer models, along with four independent equations connecting the density and the viscosity of the fluid with the attenuation and the phase velocity of the torsional wave in the wave guide, have been developed. The analysis shows that the product of the viscosity and the density of the fluid can be measured from the end reflection coefficient of the torsional wave in the wave guide and that both the viscosity and the density can be determined simultaneously from either the phase velocity or the attenuation of the torsional wave in a single cylindrical wave guide. For the simultaneous measurements of the viscosity and the density, the independent equations have to be solved numerically, for example, using Matlab (The MathWorks, Natick, MA), given either the attenuation or the phase velocity in the wave guide that is surrounded by the fluid. To demonstrate the technical feasibility, numerical simulations have been conducted to discern viscosity, phase velocity, and density, all versus attenuation, at different frequencies, and with variable dimension of a molybdenum rod, so that both the advantages and the disadvantages of the simultaneous measurements can be explored. In the end, to test the two models, preliminary experiments on two viscous standards were conducted at 23 degrees C, and good agreements have been achieved between the viscosities measured from both models and for both standards.

  8. Preliminary study of the behavioral and biological effects of high intensity 60 Hz electric fields. Quarterly technical progress report, No. 1. [Development and testing of experimental protocols and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    The major objective of this preliminary study is to develop and thoroughly test the experimental protocols and apparatus, which are planned for a major study of the behavioral and biological effects of high intensity 60 Hz electric fields. The behavior of baboons will be observed before, during, and after exposure to 60 Hz electric fields at a maximum intensity of 60 kV/m. Both individual performance (operant conditioning) and social behavior will be examined. The preliminary study will differ from the planned major study as follows: subjects will be used as their own controls; a smaller number of subjects will be run; field intensity will not be varied; the electric field should be non-uniform; the preliminary study exposure facility will be basically an outdoor facility; to avoid deterioration of plastic materials, the high intensity fields will not be turned on during or just after rainfall; and in the preliminary study the biological work will be restricted to the clinical determination of the health of subjects before and after exposure. The present report is the first of three quarterly technical progress reports. It covers approximately the first two and one-half months of activity and, therefore, consists primarily of plans. The report addresses four major areas: the high intensity field exposure facility; the field measurement instrumentation; the operation conditioning equipment; and experimental methods including experimental design and data analysis.

  9. Experimental natural circulation circuit - preliminaries results; Circuito experimental de circulacao natural - resultados experimentais preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Faccini, Jose Luiz H.; Botelho, David A.; Soares, Milton; Coutinho, Jorge A.; Freitas, Sergio Carlos [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil). E-mail: faccini@cnen.gov.br

    2000-07-01

    These are the preliminaries results of the tests carried out at experimental natural circulation system of IEN/CNEN. The experimental system is a reduced scale similar model in power, pressure, and length of a passive residual heat removal prototype system. It enables studies of natural circulation phenomena in an advanced PWR. The experimental results refer to the steps of data acquisition system calibration, power control system calibration, and single-phase operational tests. The results of single-phase tests show temperature in time measured by the thermocouples placed along the natural circulation system. It is also presented a brief commentary on the experimental results, based on theory and preliminary computational simulations. (author)

  10. A preliminary experimental investigation into lateral pedestrian-structure interaction

    DEFF Research Database (Denmark)

    Ingólfsson, Einar Thór; Georgakis, Christos; Knudsen, Anders

    2008-01-01

    This paper presents results from a preliminary experimental study on lateral human-structure dynamic interaction on footbridges using an instrumented platform. The platform has a natural frequency within the range of an average pedestrian and consists of a suspended concrete girder. With a length...... of 17 m and weight of 19.6 ton, the platform provides a realistic comparison to an actual footbridge. Based on experiments with single pedestrians walking across the platform at resonance, the fundamental dynamic load factor is determined using only the recorded acceleration signal. Furthermore, tests...

  11. Nuclear test experimental science

    Energy Technology Data Exchange (ETDEWEB)

    Struble, G.L.; Middleton, C.; Bucciarelli, G.; Carter, J.; Cherniak, J.; Donohue, M.L.; Kirvel, R.D.; MacGregor, P.; Reid, S. (eds.)

    1989-01-01

    This report discusses research being conducted at Lawrence Livermore Laboratory under the following topics: prompt diagnostics; experimental modeling, design, and analysis; detector development; streak-camera data systems; weapons supporting research.

  12. Preliminary experimental study of liquid lithium water interaction

    Energy Technology Data Exchange (ETDEWEB)

    You, X.M.; Tong, L.L.; Cao, X.W., E-mail: caoxuewu@sjtu.edu.cn

    2015-10-15

    Highlights: • Explosive reaction occurs when lithium temperature is over 300 °C. • The violence of liquid lithium water interaction increases with the initial temperature of liquid lithium. • The interaction is suppressed when the initial water temperature is above 70 °C. • Steam explosion is not ignorable in the risk assessment of liquid lithium water interaction. • Explosion strength of liquid lithium water interaction is evaluated by explosive yield. - Abstract: Liquid lithium is the best candidate for a material with low Z and low activation, and is one of the important choices for plasma facing materials in magnetic fusion devices. However, liquid lithium reacts violently with water under the conditions of loss of coolant accidents. The release of large heats and hydrogen could result in the dramatic increase of temperature and pressure. The lithium–water explosion has large effect on the safety of fusion devices, which is an important content for the safety assessment of fusion devices. As a preliminary investigation of liquid lithium water interaction, the test facility has been built and experiments have been conducted under different conditions. The initial temperature of lithium droplet ranged from 200 °C to 600 °C and water temperature was varied between 20 °C and 90 °C. Lithium droplets were released into the test section with excess water. The shape of lithium droplet and steam generated around the lithium were observed by the high speed camera. At the same time, the pressure and temperature in the test section were recorded during the violent interactions. The preliminary experimental results indicate that the initial temperature of lithium and water has an effect on the violence of liquid lithium water interaction.

  13. Experimental interstellar organic chemistry - Preliminary findings

    Science.gov (United States)

    Khare, B. N.; Sagan, C.

    1973-01-01

    Review of the results of some explicit experimental simulation of interstellar organic chemistry consisting in low-temperature high-vacuum UV irradiation of condensed simple gases known or suspected to be present in the interstellar medium. The results include the finding that acetonitrile may be present in the interstellar medium. The implication of this and other findings are discussed.

  14. Experimental interstellar organic chemistry - Preliminary findings

    Science.gov (United States)

    Khare, B. N.; Sagan, C.

    1973-01-01

    Review of the results of some explicit experimental simulation of interstellar organic chemistry consisting in low-temperature high-vacuum UV irradiation of condensed simple gases known or suspected to be present in the interstellar medium. The results include the finding that acetonitrile may be present in the interstellar medium. The implication of this and other findings are discussed.

  15. Preliminary Results of Field Emission Cathode Tests

    Science.gov (United States)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  16. A new type mixture refrigeration auto-cascade cycle with partial condensation and separation reflux exchanger and its preliminary experimental test

    Science.gov (United States)

    Wu, J. F.; Gong, M. Q.; Liu, J. L.; Luo, E. C.; Qi, Y. F.; Hu, Q. G.

    2002-05-01

    A new type of mixture refrigeration cycle with reflux exchanger is presented in this paper. In this cycle, a new type of L-V separator with inner heat and mass transfer is employed to replace the combination of conventional L-V separator or complicated rectifier and succeeding heat exchanger used in traditional auto-cascade cycle or Kleemenko cycle. A prototype is developed based on this refrigeration cycle. The thermodynamic performance is discussed as well as some other specifications such as cost, reliability, etc. The experimental results show that this prototype can reach 74 W at 135 K and 265 W at 171 K with a nominal input power of 1.5 HP.

  17. Fuskite® preliminary experimental tests based on permeation against vacuum for hydrogen recovery as a potential application in Pb15.7Li loop systems.

    Energy Technology Data Exchange (ETDEWEB)

    Sacristán, R., E-mail: mrosa.sacristan@sener.es [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Veredas, G. [EURATOM-CIEMAT Fusion Assoc., Fusion Technology Division, Av. Complutense 40, 28040 Madrid (Spain); Bonjoch, I. [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Peñalva, I. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Calderón, E. [SENER Ingeniería y Sistemas, C/ Provença 392, 5a, 08025 Barcelona (Spain); Alberro, G. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Balart, D. [SENER Ingeniería y Sistemas, Avda. Zugazarte 56, 48930 Las Arenas, Vizcaya (Spain); Sarrionandia-Ibarra, A. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Pérez, V. [SENER Ingeniería y Sistemas, Avda. Zugazarte 56, 48930 Las Arenas, Vizcaya (Spain); Ibarra, A. [EURATOM-CIEMAT Fusion Assoc., Fusion Technology Division, Av. Complutense 40, 28040 Madrid (Spain); Legarda, F. [UPV/EHU, Departamento de Ingeniería Nuclear y Mecánica de Fluidos, Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2014-10-15

    Highlights: • Full material characterization as far as hydrogen transport properties are concern. • Quantification of permeator leaks and material degasification. • Analysis of H{sub 2} recovered by means of permeation against vacuum in different conditions. • Hydrogen recovery efficiencies determination. - Abstract: Tritium recovery in fusion reactors is one of the main goals in R and D, as a limited inventory is available and its uneconomic production. That is the reason why efficient technologies are indispensable to be developed in order to achieve fast tritium recovery and its subsequent reuse in the system for increasing its self-sufficiency. In this work a flexible tritium recovery demonstrator prototype based on permeation against vacuum concept has been designed and manufactured, as well as all necessary equipment for a Pb15.7Li loop implementation in order to test and demonstrate that an in-pipe integrated solution is possible, and at the same time, to validate the manufacturing process. Thus, efficient rates for more optimized future models could be then extrapolated. The aim of this paper is to show the different testing results that have been carried out in this research project. These results include permeation properties of the material considered for the permeator, as long as it has been manufactured with a novel technique, Selective Laser Melting. They also include vacuum tests on the permeator to quantify possible leakages and to set up and analyze the capability to generate vacuum inside the permeator, and finally, permeation tests with the prototype, in a first stage with a gas mixture of hydrogen and argon inside the loop instead of Pb15.7Li.

  18. Experimental tests of quantum chromodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Dorfan, J.

    1987-04-01

    Experimental tests of quantum chromodynamics are discussed in the e/sup +/e/sup -/ continuum, in pp and anti p p collisions, in measurements of ..cap alpha../sub s/ from UPSILON decays, in deep inelastic lepton scattering, and in the measurement of the photon structure function. A large body of data relating to the testing of quantum chromodynamics is reviewed, showing qualitative agreement between the data from a wide range of processes and QCD. 66 refs., 79 figs. (LEW)

  19. Chaotic principle an experimental test

    CERN Document Server

    Bonetto, F; Garrido, P L

    1996-01-01

    The chaotic hypothesis discussed in [GC1] is tested experimentally in a simple conduction model. Besides a confirmation of the hypothesis predictions the results suggest the validity of the hypothesis in the much wider context in which, as the forcing strength grows, the attractor ceases to be an Anosov system and becomes an Axiom A attractor. A first test of the new predictions is also attempted.

  20. Preliminary Design of a LSA Aircraft Using Wind Tunnel Tests

    Directory of Open Access Journals (Sweden)

    Norbert ANGI

    2015-12-01

    Full Text Available This paper presents preliminary results concerning the design and aerodynamic calculations of a light sport aircraft (LSA. These were performed for a new lightweight, low cost, low fuel consumption and long-range aircraft. The design process was based on specific software tools as Advanced Aircraft Analysis (AAA, XFlr 5 aerodynamic and dynamic stability analysis, and Catia design, according to CS-LSA requirements. The calculations were accomplished by a series of tests performed in the wind tunnel in order to assess experimentally the aerodynamic characteristics of the airplane.

  1. Preliminary dimensioning of the IFMIF Tritium Release Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Arbeiter, Frederik, E-mail: frederik.arbeiter@kit.edu; Abou-Sena, Ali; Chen, Yuming; Freund, Jana; Klix, Axel; Kondo, Keitaro; Vladimirov, Pavel

    2013-10-15

    Highlights: • The design of the IFMIF Tritium Release Test Module is explained. • Nuclear responses in the module and specimens are calculated. • Temperature fields during irradiation are calculated by 1D methods. • The tritium budget is calculated by 1D methods. -- Abstract: As part of the ongoing Engineering Validation and Engineering Design Activities for the International Fusion Materials Irradiation Facility (IFMIF), an experimental device suitable for the irradiation and online tritium release measurements of solid breeder ceramics and beryllium is investigated. This experimental device is called the Tritium Release Test Module (TRTM). In the preliminary design phase, the possible thermal conditions, the tritium diffusion budgets, and the mechanical loads have been studied by analytical calculations and numerical codes. The most important results concern the tritium production and nuclear heating induced in the structures, the temperature distribution in the specimen region and the structure, and the diffusion of tritium through the safety barriers.

  2. Preliminary test results for the SVX4

    Energy Technology Data Exchange (ETDEWEB)

    Christofek, L.; Hanagaki, K.; Rapidis, P.; Utes, M.; /Fermilab

    2005-06-01

    We present and summarize the preliminary test results for SVX4 chip testing. There are presently two versions of the SVX4. Version 2 has on-chip bypassing and Version 1 does not. The on-chip bypassing is a layer of transistors under the front-end analog pipeline that acts as a bypassing capacitor for the voltage supply. Its size is about a microfarad. We aggressively choose to test Version 2 because of this feature. The feature is advantageous for hybrid design because it eliminates the need for an additional passive component on the hybrid itself by placing it on the actual SVX4 die. Also, the SVX4 was designed to operate in two modes: D. and CDF. One can set which mode the chip will operate by placing a jumper in the proper position on the SVX4 chip carrier. In either mode, the chip can either use the operating parameters from the shift register or the shadow register. Similarly, this is selected by placing a jumper on the SVX4 chip carrier. This chip has this feature because it was unknown whether the new design of the shadow register would be operable. The shadow register is also call the SEU register or Single Event Upset register. An introduction into the functionality of the chip and an explanation on the difference between D. and CDF mode can be found in the SVX4 User's Manual [1].

  3. Preliminary experimental study of a carbon fiber array cathode

    Science.gov (United States)

    Li, An-kun; Fan, Yu-wei

    2016-08-01

    The preliminary experimental results of a carbon fiber array cathode for the magnetically insulated transmission line oscillator (MILO) operations are reported. When the diode voltage and diode current were 480 kV and 44 kA, respectively, high-power microwaves with a peak power of about 3 GW and a pulse duration of about 60 ns were obtained in a MILO device with the carbon fiber array cathode. The preliminary experimental results show that the shot-to-shot reproducibility of the diode current and the microwave power is stable until 700 shots. No obvious damage or deterioration can be observed in the carbon fiber surface morphology after 700 shots. Moreover, the cathode performance has no observable deterioration after 700 shots. In conclusion, the maintain-free lifetime of the carbon fiber array cathode is more than 700 shots. In this way, this carbon fiber array cathode offers a potential replacement for the existing velvet cathode.

  4. Preliminary results of steel containment vessel model test

    Energy Technology Data Exchange (ETDEWEB)

    Luk, V.K.; Hessheimer, M.F. [Sandia National Labs., Albuquerque, NM (United States); Matsumoto, T.; Komine, K.; Arai, S. [Nuclear Power Engineering Corp., Tokyo (Japan); Costello, J.F. [Nuclear Regulatory Commission, Washington, DC (United States)

    1998-04-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11--12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented.

  5. Experimental Use of Signed Presentations of the Verbal Scale of the WISC-R with Profoundly Deaf Children: A Preliminary Report of the Sign Selection Process and Experimental Test Procedures.

    Science.gov (United States)

    Miller, Margery Silberman

    The paper provides a theoretical framework for the inclusion of a verbal intelligence test as part of the psychodiagnostic assessment battery used with deaf children. Descriptions are provided for three selected sign language varieties being used in a study designed to examine performance of 30 deaf children (9-16 years old) on signed…

  6. Experimental Use of Signed Presentations of the Verbal Scale of the WISC-R with Profoundly Deaf Children: A Preliminary Report of the Sign Selection Process and Experimental Test Procedures.

    Science.gov (United States)

    Miller, Margery Silberman

    The paper provides a theoretical framework for the inclusion of a verbal intelligence test as part of the psychodiagnostic assessment battery used with deaf children. Descriptions are provided for three selected sign language varieties being used in a study designed to examine performance of 30 deaf children (9-16 years old) on signed…

  7. The freshwater snail lymnaea rubiginosa as an experimental host of Angiostrongylus malaysiensis: a preliminary report.

    Science.gov (United States)

    Dondero, T J; Lim, B L

    1976-03-01

    Preliminary studies have shown that Lymnaea rubiginosa, a common fresh-water snail in Peninsular Malaysia, which is easily colonized and reared in the laboratory, is a capable experimental intermediate host for Angiostrongylus malaysiensis. Overall 73% of the snails tested became infected following 6 hours exposure to infective rat faeces. Higher infection rates, up to 100%, and heavier worm loads, occurred among the larger sized snails. Snail attrition was low except when very heavy worm loads were acquired.

  8. Testing the Preliminary X-33 Navigation System

    Science.gov (United States)

    Lomas, James J.; Mitchell, Daniel W.; Freestone, Todd M.; Lee, Charles; Lessman, Craig; Foster, Lee D. (Technical Monitor)

    2001-01-01

    The X-33 Reusable Launch Vehicle (RLV) must meet the demanding requirements of landing autonomously on a narrow landing strip following a flight that reaches an altitude of up to 200,000 feet and a speed in excess of Mach 9 with significant in-flight energy bleed-off maneuvers. To execute this flight regimen a highly reliable avionics system has been designed that includes three LN-100G Inertial Navigation System/Global Positioning System (INS/GPS) units as the primary navigation system for the X-33. NASA's Marshall Space Flight Center (MSFC) tested an INS/GPS system in real-time simulations to determine the ability of this navigation suite to meet the in flight and autonomous landing requirements of the X-33 RLV. A total of sixty-one open loop tests were performed to characterize the navigation accuracy of the LN-100G. Twenty-seven closed-loop tests were also performed to evaluate the performance of the X-33 Guidance, Navigation and Control (GN&C) algorithms with the real navigation hardware. These closed-loop tests were also designed to expose any integration or operational issues with the real-time X-33 vehicle simulation. Dynamic road tests of the INS/GPS were conducted by Litton to assess the performance of differential and nondifferential INS/GPS hybrid navigation solutions. The results of the simulations and road testing demonstrate that this novel solution is capable of meeting the demanding requirements of take-off, in-flight navigation, and autonomous landing of the X-33 RLV. This paper describes the test environment developed to stimulate the LN-100G and discusses the results of this test effort. This paper also presents recommendations for a navigation system suitable to an operational RLV system.

  9. Platform for dynamic tests: preliminary studies, design and construction

    Directory of Open Access Journals (Sweden)

    J. E. Campuzano

    . The platform was built and has been done a preliminary experimental study to obtain the first natural frequencies.

  10. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2007-08-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  11. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2010-06-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  12. Experimental Tests Of Paleoclassical Transport

    Energy Technology Data Exchange (ETDEWEB)

    Callen, J D; Anderson, J K; Arlen, T C; Bateman, G; Budny, R V; Fujita, T; Greenfield, C M; Greenwald, M; Groebner, R J; Hill, D N; Hogeweij, G D; Kaye, S M; Kritz, A H; Lazarus, E A; Leonard, A C; Mahdavi, M A; McLean, H S; Osborne, T H; Pankin, A Y; Petty, C C; Sarff, J S; St. John, H E; Stacey, W M; Stutman, D; Synakowski, E J; Tritz, K

    2006-09-12

    Predictions of the recently developed paleoclassical transport model are compared with data from many toroidal plasma experiments: electron heat diffusivity in DIII-D, C-Mod and NSTX ohmic and near-ohmic plasmas; transport modeling of DIII-D ohmic-level discharges and of the RTP ECH 'stair-step' experiments with eITBs at low order rational surfaces; investigation of a strong eITB in JT-60U; H-mode Te edge pedestal properties in DIII-D; and electron heat diffusivities in non-tokamak experiments (NSTX/ST, MST/RFP, SSPX/spheromak). The radial electron heat transport predicted by the paleoclassical model is found to agree with a wide variety of ohmic-level experimental results and to set the lower limit (within a factor {approx} 2) for the radial electron heat transport in most resistive, current-carrying toroidal plasmas -- unless it is exceeded by fluctuation-induced transport, which often occurs in the edge of L-mode plasmas and when the electron temperature is high ({approx}>T{sub e}{sup crit} {approx}B{sup 2/3}{bar {alpha}}{sup 1/2} keV) because then paleoclassical transport becomes less than gyro-Bohm-level anomalous transport.

  13. Experimental test of nonlocal causality.

    Science.gov (United States)

    Ringbauer, Martin; Giarmatzi, Christina; Chaves, Rafael; Costa, Fabio; White, Andrew G; Fedrizzi, Alessandro

    2016-08-01

    Explaining observations in terms of causes and effects is central to empirical science. However, correlations between entangled quantum particles seem to defy such an explanation. This implies that some of the fundamental assumptions of causal explanations have to give way. We consider a relaxation of one of these assumptions, Bell's local causality, by allowing outcome dependence: a direct causal influence between the outcomes of measurements of remote parties. We use interventional data from a photonic experiment to bound the strength of this causal influence in a two-party Bell scenario, and observational data from a Bell-type inequality test for the considered models. Our results demonstrate the incompatibility of quantum mechanics with a broad class of nonlocal causal models, which includes Bell-local models as a special case. Recovering a classical causal picture of quantum correlations thus requires an even more radical modification of our classical notion of cause and effect.

  14. Experimental test of nonlocal causality

    Science.gov (United States)

    Ringbauer, Martin; Giarmatzi, Christina; Chaves, Rafael; Costa, Fabio; White, Andrew G.; Fedrizzi, Alessandro

    2016-01-01

    Explaining observations in terms of causes and effects is central to empirical science. However, correlations between entangled quantum particles seem to defy such an explanation. This implies that some of the fundamental assumptions of causal explanations have to give way. We consider a relaxation of one of these assumptions, Bell’s local causality, by allowing outcome dependence: a direct causal influence between the outcomes of measurements of remote parties. We use interventional data from a photonic experiment to bound the strength of this causal influence in a two-party Bell scenario, and observational data from a Bell-type inequality test for the considered models. Our results demonstrate the incompatibility of quantum mechanics with a broad class of nonlocal causal models, which includes Bell-local models as a special case. Recovering a classical causal picture of quantum correlations thus requires an even more radical modification of our classical notion of cause and effect. PMID:27532045

  15. Preliminary Test for Nonlinear Input Output Relations in SISO Systems

    DEFF Research Database (Denmark)

    Knudsen, Torben

    2000-01-01

    This paper discusses and develops preliminary statistical tests for detecting nonlinearities in the deterministic part of SISO systems with noise. The most referenced method is unreliable for common noise processes as e.g.\\ colored. Therefore two new methods based on superposition and sinus input...

  16. The picture test of separation and individuation - preliminary research

    OpenAIRE

    Gregor Žvelc; Maša Žvelc

    2000-01-01

    Authors introduce a new instrument, which they developed for measuring separation and individuation process and attachment in adolescence and adulthood. The Picture Test of Separation and Individuation (PTSI) is a semi–projective test. It consists of various pictures, which represent relationships with significant others. PTSI is divided into three subtests: Relationship with Mother, Relationship with Father and Attachment. In a preliminary research on a sample of college and university...

  17. The Experimental Design Ability Test (EDAT)

    Science.gov (United States)

    Sirum, Karen; Humburg, Jennifer

    2011-01-01

    Higher education goals include helping students develop evidence based reasoning skills; therefore, scientific thinking skills such as those required to understand the design of a basic experiment are important. The Experimental Design Ability Test (EDAT) measures students' understanding of the criteria for good experimental design through their…

  18. Adaptive structures - Test hardware and experimental results

    Science.gov (United States)

    Wada, Ben K.; Fanson, James L.; Chen, Gun-Shing; Kuo, Chin-Po

    1990-01-01

    The facilities and procedures used at JPL to test adaptive structures such as the large deployable reflector (LDR) are described and preliminary results are reported. The applications of adaptive structures in future NASA missions are outlined, and the techniques which are employed to modify damping, stiffness, and isolation characteristics, as well as geometric changes, are listed. The development of adaptive structures is shown to be effective as a result of new actuators and sensors, and examples are listed for categories such as fiber optics, shape-memory materials, piezoelectrics, and electrorheological fluids. Some ground test results are described for laboratory truss structures and truss test beds, which are shown to be efficient and easy to assemble in space. Adaptive structures are shown to be important for precision space structures such as the LDR, and can alleviate ground test requirements.

  19. Definition study for an extended manned test of a regenerative life support system, preliminary test plan

    Science.gov (United States)

    1971-01-01

    A preliminary plan and procedure are presented for conducting an extended manned test program for a regenerative life support system. Emphasis will be placed on elements associated with long-term system operation and long-term uninterrupted crew confinement.

  20. Preliminary experimental results on studying possibility of variable mass liner (VML) formation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The main objective of the present experiment was to study the formation process and initial stage of acceleration of a variable-mass plasma liner (VML). The method is based on magnetic acceleration of a liner with the mass reduced during such acceleration. The experiment was carried out on February 16 at VNIIEF. This report describes the results of measurements obtained in the experiment and preliminary analysis of the results characterizing operation of the test facility main units: helical EMG; 5-module disk EMG 400 mm in diameter (DEMG); ponderomotive unit (PU) with a cylindric condensed liner and a special tooth-cutoff. The first part of the report presents measurement results obtained on the VNIIEF`s diagnostic equipment that are compared with those obtained by American specialists on their diagnostic equipment. Information submitted by American specialists is included in part 2 of this report. The second part of the report presents preliminary computational-theoretic analysis of the main measured results describing operation of DEMG TL system in the experiment; experimental data are compared with theoretical ones obtained before and after the experiment. But more emphasis is placed on the data preliminary analysis indicating that in the experiment a variable mass liner is formed (VML or plasma bubble).

  1. Experimental characterization of composites. [load test methods

    Science.gov (United States)

    Bert, C. W.

    1975-01-01

    The experimental characterization for composite materials is generally more complicated than for ordinary homogeneous, isotropic materials because composites behave in a much more complex fashion, due to macroscopic anisotropic effects and lamination effects. Problems concerning the static uniaxial tension test for composite materials are considered along with approaches for conducting static uniaxial compression tests and static uniaxial bending tests. Studies of static shear properties are discussed, taking into account in-plane shear, twisting shear, and thickness shear. Attention is given to static multiaxial loading, systematized experimental programs for the complete characterization of static properties, and dynamic properties.

  2. The picture test of separation and individuation - preliminary research

    Directory of Open Access Journals (Sweden)

    Gregor Žvelc

    2000-06-01

    Full Text Available Authors introduce a new instrument, which they developed for measuring separation and individuation process and attachment in adolescence and adulthood. The Picture Test of Separation and Individuation (PTSI is a semi–projective test. It consists of various pictures, which represent relationships with significant others. PTSI is divided into three subtests: Relationship with Mother, Relationship with Father and Attachment. In a preliminary research on a sample of college and university students authors studied basic properties of the test. The results of the research indicate that PTSI is consistent with theoretical background, has good sensitivity and is economical. The Picture Test of Separation and Individuation enables quick but complex insight into individual's relationships with significant others as well as into his/her stage of separation and individuation process. Considering satisfying results of pilot study, authors suggest further research for validation of the test.

  3. Experimental test of airplane boarding methods

    CERN Document Server

    Steffen, Jason H

    2011-01-01

    We report the results of an experimental comparison of different airplane boarding methods. This test was conducted in a mock 757 fuselage, located on a Southern California soundstage, with 12 rows of six seats and a single aisle. Five methods were tested using 72 passengers of various ages. We found a significant reduction in the boarding times of optimized methods over traditional methods. These improved methods, if properly implemented, could result in a significant savings to airline companies.

  4. Modeling and Testing of EVs - Preliminary Study and Laboratory Development

    DEFF Research Database (Denmark)

    Yang, Guang-Ya; Marra, Francesco; Nielsen, Arne Hejde

    2010-01-01

    impact at different geographical areas, as well as driving and charging patterns. Electric circuit model is deployed in this work to represent the electrical properties of a lithium-ion battery. This paper reports the preliminary modeling and validation work based on manufacturer data sheet and realistic......Electric vehicles (EVs) are expected to play a key role in the future energy management system to stabilize both supply and consumption with the presence of high penetration of renewable generation. A reasonably accurate model of battery is a key element for the study of EVs behavior and the grid...... tests, followed by the suggestions towards a feasible battery model for further studies....

  5. Design and preliminary testing of the RIC hybrid knee prosthesis.

    Science.gov (United States)

    Lenzi, T; Sensinger, J; Lipsey, J; Hargrove, L; Kuiken, T

    2015-08-01

    We present a novel hybrid knee prosthesis that uses a motor, transmission and control system only for active dynamics tasks, while relying on a spring/damper system for passive dynamics activities. Active dynamics tasks require higher torque, lower speed, and occur less frequently than passive dynamic activities. By designing the actuation system around active tasks alone, we achieved a lightweight design (1.7 Kg w/o battery) without sacrificing peak torque (85Nm repetitive). Preliminary tests performed by an able-bodied person using a bypass orthosis show that the hybrid knee can support reciprocal stairs ambulation with low electrical energy consumption.

  6. Preliminary wind tunnel tests on the pedal wind turbine

    Science.gov (United States)

    Vinayagalingam, T.

    1980-06-01

    High solidity-low speed wind turbines are relatively simple to construct and can be used advantageously in many developing countries for such direct applications as water pumping. Established designs in this class, such as the Savonius and the American multiblade rotors, have the disadvantage that their moving surfaces require a rigid construction, thereby rendering large units uneconomical. In this respect, the pedal wind turbine recently reported by the author and which incorporates sail type rotors offers a number of advantages. This note reports preliminary results from a series of wind tunnel tests which were carried out to assess the aerodynamic torque and power characteristics of the turbine.

  7. Experimental Concepts for Testing Seismic Hazard Models

    Science.gov (United States)

    Marzocchi, W.; Jordan, T. H.

    2015-12-01

    Seismic hazard analysis is the primary interface through which useful information about earthquake rupture and wave propagation is delivered to society. To account for the randomness (aleatory variability) and limited knowledge (epistemic uncertainty) of these natural processes, seismologists must formulate and test hazard models using the concepts of probability. In this presentation, we will address the scientific objections that have been raised over the years against probabilistic seismic hazard analysis (PSHA). Owing to the paucity of observations, we must rely on expert opinion to quantify the epistemic uncertainties of PSHA models (e.g., in the weighting of individual models from logic-tree ensembles of plausible models). The main theoretical issue is a frequentist critique: subjectivity is immeasurable; ergo, PSHA models cannot be objectively tested against data; ergo, they are fundamentally unscientific. We have argued (PNAS, 111, 11973-11978) that the Bayesian subjectivity required for casting epistemic uncertainties can be bridged with the frequentist objectivity needed for pure significance testing through "experimental concepts." An experimental concept specifies collections of data, observed and not yet observed, that are judged to be exchangeable (i.e., with a joint distribution independent of the data ordering) when conditioned on a set of explanatory variables. We illustrate, through concrete examples, experimental concepts useful in the testing of PSHA models for ontological errors in the presence of aleatory variability and epistemic uncertainty. In particular, we describe experimental concepts that lead to exchangeable binary sequences that are statistically independent but not identically distributed, showing how the Bayesian concept of exchangeability generalizes the frequentist concept of experimental repeatability. We also address the issue of testing PSHA models using spatially correlated data.

  8. Preliminary Feasibility Testing of the BRIC Brine Water Recovery Concept

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Pickering, Karen D.

    2011-01-01

    The Brine Residual In-Containment (BRIC) concept was developed as a new technology to recover water from spacecraft wastewater brines. Such capability is considered critical to closing the water loop and achieving a sustained human presence in space. The intention of the BRIC concept is to increase the robustness and efficiency of the dewatering process by performing drying inside the container used for the final disposal of the residual brine solid. Recent efforts in the development of BRIC have focused on preliminary feasibility testing using a laboratory- assembled pre-prototype unit. Observations of the drying behavior of actual brine solutions processed under BRIC-like conditions has been of particular interest. To date, experiments conducted with three types of analogue spacecraft wastewater brines have confirmed the basic premise behind the proposed application of in-place drying for these solutions. Specifically, the dried residual mass from these solutions have tended to exhibit characteristics of adhesion and flow that are expected to continue to challenge process stream management in spacecraft brine dewatering system designs. Yet, these same characteristics may favor the development of capillary- and surface-tension-based approaches envisioned as part of an ultimate microgravity-compatible BRIC design. In addition, preliminary feasibility testing of the BRIC pre-prototype confirmed that high rates of water recovery, up to 98% of the available brine water, may be possible while still removing the majority of the brine contaminants from the influent brine stream. These and other observations from testing are reported.

  9. Solar Stirling power generation - Systems analysis and preliminary tests

    Science.gov (United States)

    Selcuk, M. K.; Wu, Y.-C.; Moynihan, P. I.; Day, F. D., III

    1977-01-01

    The feasibility of an electric power generation system utilizing a sun-tracking parabolic concentrator and a Stirling engine/linear alternator is being evaluated. Performance predictions and cost analysis of a proposed large distributed system are discussed. Design details and preliminary test results are presented for a 9.5 ft diameter parabolic dish at the Jet Propulsion Laboratory (Caltech) Table Mountain Test Facility. Low temperature calorimetric measurements were conducted to evaluate the concentrator performance, and a helium flow system is being used to test the solar receiver at anticipated working fluid temperatures (up to 650 or 1200 C) to evaluate the receiver thermal performance. The receiver body is designed to adapt to a free-piston Stirling engine which powers a linear alternator assembly for direct electric power generation. During the next phase of the program, experiments with an engine and receiver integrated into the concentrator assembly are planned.

  10. Experimental Tests of Local Cosmological Expansion Rates

    CERN Document Server

    Widom, A; Srivastava, Y

    2015-01-01

    Cosmological expansion on a local scale is usually neglected in part due to its smallness, and in part due to components of bound systems (especially those bound by non-gravitational forces such as atoms and nuclei) not following the geodesics of the cosmological metric. However, it is interesting to ask whether or not experimental tests of cosmological expansion on a local scale (well within our own galaxy) might be experimentally accessible in some manner. We point out, using the Pioneer satellites as an example, that current satellite technology allows for this possibility within time scales of less than one human lifetime.

  11. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  12. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  13. ADDITIVE TESTING FOR IMPROVED SULFUR RETENTION: PRELIMINARY REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Amoroso, J.; Fox, K.

    2011-09-07

    The Savannah River National Laboratory is collaborating with Alfred University to evaluate the potential for additives in borosilicate glass to improve sulfur retention. This preliminary report provides further background on the incorporation of sulfur in glass and outlines the experiments that are being performed by the collaborators. A simulated waste glass composition has been selected for the experimental studies. The first phase of experimental work will evaluate the impacts of BaO, PbO, and V{sub 2}O{sub 5} at concentrations of 1.0, 2.0, and 5.0 wt % on sulfate retention in simulated high level waste borosilicate glass. The second phase of experimental work will evaluate the effects of time at the melt temperature on sulfur retention. The resulting samples will be characterized to determine the amount of sulfur remaining as well as to identify the formation of any crystalline phases. The results will be used to guide the future selection of frits and glass forming chemicals in vitrifying Department of Energy wastes containing high sulfur concentrations.

  14. Design and preliminary test results of Daya Bay RPC modules*

    Energy Technology Data Exchange (ETDEWEB)

    Hackenburg, R.

    2011-09-01

    Resistive Plate Chamber (RPC) modules will be used as one part of the cosmic muon veto system in the Daya Bay reactor neutrino experiment. A total of 189 RPC modules will cover the three water pools in the experiment. To achieve track reconstruction and high efficiency, each module consists of 4 layers, each of which contains two sizes of bare chambers. The placement of bare chambers is reversed in different layers to reduce the overlapping dead areas. The module efficiency and patch efficiency were studied both in simulation and test of the data analysis. 143 modules have been constructed and tested. The preliminary study shows that the module and patch 3 out of 4 layers efficiency reaches about 98%.

  15. Design and preliminary test results of Daya Bay RPC modules

    Institute of Scientific and Technical Information of China (English)

    XU Ji-Lei; Logan Lebanowski; Cullen Newsom; Lin Shih-Kai; Jonathan Link; MA Lie-Hua; Viktor Pě(c); Vit Vorobel; CHEN Jin; LIU Jin-Chang; ZHOU Yong-Zhao; GUAN Meng-Yun; LIANG Hao; YANG Chang-Gen; WANG Yi-Fang; ZHANG Jia-Wen; LU Chang-Guo; Kirk McDonald; Robert Hackenburg; Kwong Lau

    2011-01-01

    Resistive Plate Chamber(RPC)modules will be used as one part of the cosmic muon veto system in the Days Bay reactor neutrino experiment.A total of 189 RPC modules will cover the three water pools in the experiment.To achieve track reconstruction and high efficiency,each module consists of 4 layers,each of which contains two sizes of bare chambers.The placement of bare chambers is reversed in different layers to reduce the overlapping dead areas.The module efficiency and patch efficiency were studied both in simulation and test of the data analysis.143 modules have been constructed and tested.The preliminary study shows that the module and patch 3 out of 4 layers efficiency reaches about 98%.

  16. Experimental testing of constructivism and related theories.

    Science.gov (United States)

    Fidelman, U

    1991-10-01

    The purpose of this article is to show that experimental scientific methods can be applied to explain how the analytic mechanism of the left cerebral hemisphere and the synthetic mechanism of the right one create complex cognitive constructions like ontology and mathematics. Nominalism and ordinal mathematical concepts are related to the analytic left hemisphere while Platonism and cardinal mathematical concepts are related to the synthetic right one. Thus persons with a dominant left hemisphere tend to prefer nominalist ontology and have more aptitude for ordinal mathematics than for cardinal mathematics, while persons with a dominant right hemisphere tend to prefer platonist ontology and have more aptitude for cardinal mathematics than for ordinal mathematics. It is further explained how the Kantism temporal mode of perceiving experience can be related to the left hemisphere while the Kantian spatial mode of perceiving experience can be related to the right hemisphere. This relation can be tested experimentally, thus the Kantian source of constructivism, and through it constructivism itself, can be tested experimentally.

  17. Results of Preliminary Tests of PAR Bunch Cleaning

    CERN Document Server

    Yao, Chihyuan; Grelick, Arthur; Lumpkin, Alex H; Sereno, Nicholas S

    2005-01-01

    A particle accumulator ring (PAR) is used at the Advanced Photon Source (APS) to collect multiple linac bunches and compress them into a 0.3-ns (rms) single bunch for booster injection. A 9.77-MHz fundamental rf system and a 117.3-MHz harmonic rf system are employed for initial beam capture and bunch length compression. Satellite bunches with very low charge form due to rf phase drifts or beam loading change. These satellites, when injected into the booster and then into the storage ring (SR), cause bunch impurity at three buckets from the target bucket. Storage ring and booster bunch cleaning was tried but proved to be difficult due to the top-up mode of operation in the storage ring and tune drift in the booster synchrotron. Recently we implemented a PAR bunch-cleaning system with tune-modulated harmonic rf knockout. Preliminary tests gave a measured SR bunch purity of better than 10

  18. Installation of ECR2 at LNS and Preliminary tests

    CERN Document Server

    Gammino, S; Ciavola, G; Castro, M; Chines, F; Marletta, S; Bieth, C; Sortais, P; Kantas, S

    1999-01-01

    The source ECR2 has been built in 1998 by Pantechnik, according to the design suggested by LNS Ion Source Group. This design entails some improvements with respect to a standard CAPRICE-type source: a) the magnetic field (up to 1.6 T axial, 1.1 T radial) allows to operate the source at 14 GHz in High B mode and at 18 GHz; b) two frequency heating can be used; c) an aluminum made plasma chamber is used in place of the stainless steel one. The main features of ECR2 along with a review of the preliminary tests will be outlined. Typical currents for fully stripped nitrogen are about 25 emA; for the heaviest ions, 1 emA of Kr28+ and 10 emA of Ta27+ have been measured. The installation at LNS has been completed recently and the details will be given.

  19. Preliminary experimental investigation of boundary layer in decelerating flow

    Directory of Open Access Journals (Sweden)

    Příhoda J.

    2013-04-01

    Full Text Available Investigations of characteristics of turbulence inside boundary layer under decelerating flow were studied by means of constant temperature anemometer. The decelerating flow was simulated in the closed circuit wind tunnel 0.9 m × 0.5 m at IT AS CR. The free stream turbulence was either natural o risen up by square mesh plane grid. The details of experimental settings and measurement procedures of the instantaneous longitudinal velocity component are described and the distributions of intensity, skewness and kurtosis of turbulent fluctuations are discussed in the contribution.

  20. Preliminary Experimental Investigation on MHD Power Generation Using Seeded Supersonic Argon Flow as Working Fluid

    Institute of Scientific and Technical Information of China (English)

    LI Yiwen; LI Yinghong; LU Haoyu; ZHU Tao; ZHANG Bailing; CHEN Feng; ZHAO Xiaohu

    2011-01-01

    This paper presents a preliminary experimental investigation on magnetohydrodynamic (MHD) power generation using seeded supersonic argon flow as working fluid.Helium and argon are used as driver and driven gas respectively in a shock tunnel.Equilibrium contact surface operating mode is used to obtain high temperature gas,and the conductivity is obtained by adding seed K2CO3 powder into the driven section.Under the conditions of nozzle inlet total pressure being 0.32 MPa,total temperature 6 504 K,magnetic field density about 0.5 T and nozzle outlet velocity 1 959 m/s,induction voltage and short-circuit current of the segmentation MHD power generation channel are measured,and the experimental results agree with theoretical calculations; the average conductivity is about 20 S/m calculated from characteristics of voltage and current.When load factor is 0.5,the maximum power density of the MHD power generation channel reaches 4.797 1 MW/m3,and the maximum enthalpy extraction rate is 0.34%.Finally,the principle and method of indirect testing for gas state parameters are derived and analyzed.

  1. Potential of preliminary test methods to predict biodegradation performance of petroleum hydrocarbons in soil.

    Science.gov (United States)

    Aichberger, H; Hasinger, Marion; Braun, Rudolf; Loibner, Andreas P

    2005-03-01

    Preliminary tests at different scales such as degradation experiments (laboratory) in shaking flasks, soil columns and lysimeters as well as in situ respiration tests (field) were performed with soil from two hydrocarbon contaminated sites. Tests have been evaluated in terms of their potential to provide information on feasibility, degradation rates and residual concentration of bioremediation in the vadose zone. Sample size, costs and duration increased with experimental scale in the order shaking flasks - soil columns - lysimeter - in situ respiration tests, only time demand of respiration tests was relatively low. First-order rate constants observed in degradation experiments exhibited significant differences between both, different experimental sizes and different soils. Rates were in line with type and history of contamination at the sites, but somewhat overestimated field rates particularly in small scale experiments. All laboratory experiments allowed an estimation of residual concentrations after remediation. In situ respiration tests were found to be an appropriate pre-testing and monitoring tool for bioventing although residual concentrations cannot be predicted from in situ respiration tests. Moreover, this method does not account for potential limitations that might hamper biodegradation in the longer term but only reflects the actual degradation potential when the test is performed.

  2. A preliminary experimental study on virtual sound barrier system

    Science.gov (United States)

    Zou, Haishan; Qiu, Xiaojun; Lu, Jing; Niu, Feng

    2007-10-01

    Virtual sound barrier (VSB) is an array of loudspeakers and microphones forming an acoustic barrier, which creates a quiet zone without blocking air and light. A 16-channel cylindrical VSB system has been developed and its feasibility is verified by both numerical simulations and experiments. Experimental results in a normal room show that it can create a quiet zone larger than the size of a human head in the low-middle frequency, with a total sound pressure level reduction of more than 10 dB in the quiet zone. The control performance of the system with respect to the frequency, the distribution of the error sensors and the control sources are discussed.

  3. Photon Detection with Cooled Avalanche Photodiodes: Theory and Preliminary Experimental Results

    Science.gov (United States)

    Robinson, D. L.; Hays, D. A.

    1985-01-01

    Avalanche photodiodes (APDs) can be operated in a geiger-tube mode so that they can respond to single electron events and thus be used as photon counting detectors. Operational characteristics and theory of APDs while used in this mode are analyzed and assessed. Preliminary experimental investigation of several commercially available APDs has commenced, and initial results for dark count statistics are presented.

  4. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  5. Preliminary experimental research for silver recovery from radiographic films

    Science.gov (United States)

    Cânda, L. R.; Ardelean, E.

    2017-01-01

    Global demand for silver remains steadily to about 1,000 million ounces (28349500 kg), of which around 600 million ounces (17009700 kg) are used in industrial applications. Extraction of silver from the ore is expensive and harmful to the environment and low efficiency. X-ray films represent an important worldwide consumer as research on recovery of silver from exposed radiographic films must be oriented to achieve a maximum recovery and a high purity silver, with methods through the by-products will be less polluting for the environment. The paper presents some laboratory tests referring to the recovery of silver from radiographic films by leaching with sodium hydroxide. Two series of experiments were performed with different amounts of used X-ray film.

  6. [Peritoneal equilibration test: Conventional versus adapted. Preliminary study].

    Science.gov (United States)

    Zaloszyc, Ariane; Schmitt, Claus Peter; Schaefer, Betti; Doutey, Armelle; Terzic, Joëlle; Menouer, Soraya; Higel, Laetitia; Fischbach, Michel

    2017-02-01

    Conventional automated peritoneal dialysis (APD) is prescribed as a repetition of cycles with the same dwell time and the same fill volume. Water and sodium balance remains a common problem among patients on peritoneal dialysis. More recently, adapted automated peritoneal dialysis was described, as a combination of short dwells with a low volume, in order to enhance ultrafiltration, followed by long dwells with a large fill volume to favor solute removal. We performed a preliminary crossover study on 4 patients. The total amount of dialysate was the same, i.e. 2L/m(2) as well as the total duration of the test, i.e. 150 minutes. The conventional test was made with two identical cycles, each cycle had a fill volume of 1L/m(2) and a duration of 75 minutes, while the adapted test was performed with one short cycle, i.e. 30 minutes with a low fill volume, i.e. 0.6L/m(2), followed by a long cycle, i.e. 120 minutes, with a large fill volume, i.e. 1.4L/m(2). Sodium extraction was improved by 29.3mmol/m(2) (169%) in the adapted test in comparison to the conventional test. Ultrafiltration was enhanced by 159mL/m(2) (128%) in the adapted test compared to the conventional one. Glucose absorption was decreased by 35% in the adapted test in comparison to the conventional test and osmotic conductance was also improved. In conclusion, adapted dialysis may allow for a better volume and sodium balance, since we observed an improvement in sodium extraction and ultrafiltration. This pre-study authorizes an improvement of the European Pediatric Study's protocol on Adapted APD, already started and which will continue in the next months. Copyright © 2016 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  7. Preliminary Design Report of Fluid System of PDRC Performance Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae-Ho; Eoh, Jae-Hyuk; Seong, Seung-Hwan; Han, Ji-Woong; Choi, Byoung-Hae; Kim, Seong-O

    2008-10-15

    PDRC (Passive Decay Heat Removal Circuit) is a safety grade passive residual heat removal system of KALIMER-600. In order to assess the long- and short-term cooling capabilities of PDRC and produce the experimental data for the verification of the performance and safety analysis codes, PDRC performance test was planned for. In this study, the overall design requirements and the preliminary design data for the fluid system of test facility are presented. The fluid system of the facility is composed of the primary heat transport system, the PDRC, the IHX air cooling system and the sodium supply/purification system. The preliminarily designed facility is scaled-down to 1/4 for length, 1/400 for volume from the primary heat transport system and the PDRC of KALIMER-600 based on a reliable scaling method. It can simulate the cooling of primary heat transport system for the full temperature condition in case of the reactor and pump trips. The produced preliminary design data will be used in the future as the basic information for a detailed design, an establishment of experimental requirement and an assessment of the appropriateness of facility design.

  8. Preliminary Design of Large Scale Sodium Thermal-Hydraulic Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Ho; Kim, Tae Joon; Eoh, Jae Hyuk; Lee, Hyeong Yeon; Lee, Jae Han; Jeong, Ji Young; Park, Su Ki; Han, Ji Woong; Yoo, Yong Hwan; Lee, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-10-15

    A large scale sodium thermal-hydraulic test facility is being designed for verification of the advanced design concept of the passive decay heat removal circuit (PDRC) in a medium- or large-sized pool-type SFR. In the test, its cooling capability during the long- and short-term periods after the reactor trip will be evaluated, and also the produced experimental data will be utilized for the assessment and verification of the safety and performance analysis codes. Starting with the preliminary design of the test facility this year using KALIMER-600 as a reference reactor, the basic and the detailed designs will be made through 2011-2012 based on the demonstration reactor which is intended to be constructed by 2028 according to a long-term national SFR development plan. The installation is scheduled to be completed by the end of 2013, and the main experiments will commence from 2015 after the startup test in 2014. This paper briefly introduces the preliminary design features which were produced as a first step to assess the appropriateness of the facility design methodology.

  9. Expanded microchannel heat exchanger: design, fabrication and preliminary experimental test

    CERN Document Server

    Denkenberger, David C; Pearce, Joshua M; Zhai, John; 10.1177/0957650912442781

    2012-01-01

    This paper first reviews non-traditional heat exchanger geometry, laser welding, practical issues with microchannel heat exchangers, and high effectiveness heat exchangers. Existing microchannel heat exchangers have low material costs, but high manufacturing costs. This paper presents a new expanded microchannel heat exchanger design and accompanying continuous manufacturing technique for potential low-cost production. Polymer heat exchangers have the potential for high effectiveness. The paper discusses one possible joining method - a new type of laser welding named "forward conduction welding," used to fabricate the prototype. The expanded heat exchanger has the potential to have counter-flow, cross-flow, or parallel-flow configurations, be used for all types of fluids, and be made of polymers, metals, or polymer-ceramic precursors. The cost and ineffectiveness reduction may be an order of magnitude or more, saving a large fraction of primary energy. The measured effectiveness of the prototype with 28 micro...

  10. Environmental Survey preliminary report, Nevada Test Site, Mercury, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Nevada Test Site (NTS), conducted June 22 through July 10, 1987. The Survey is being conducted by a multidisciplinary team of environmental specialists led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team members are outside experts being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the NTS. The Survey covers all environment media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations and activities performed at the NTS, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing certain environmental problems identified during its on-site activities. The Sampling and Analysis Plan is being executed by the Battelle Columbus Division under contract with DOE. When completed, the results will be incorporated into the NTS Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the NTS Survey. 165 refs., 42 figs., 52 tabs.

  11. Preliminary Tests Of The Decris-sc Ion Source

    CERN Document Server

    Efremov, A; Bechterev, V; Bogomolov, S L; Bondarenko, P G; Datskov, V I; Dmitriev, S; Drobin, V; Lebedev, A; Leporis, M; Malinowski, H; Nikiforov, A; Paschenko, S V; Seleznev, V; Shishov, Yu A; Smirnov, Yu; Tsvineva, G; Yakovlev, B; Yazvitsky, N Yu

    2004-01-01

    A new "liquid He-free" superconducting Electron Cyclotron Resonance Ion Source DECRIS-SC, to be used as injector for the IC-100 small cyclotron, has been designed by FLNR and LHE JINR. The main feature is that a compact refrigerator of Gifford-McMahon type is used to cool the solenoid coils. For the reason of very small cooling power at 4.2 K (about 1 W) our efforts were to optimize the magnetic structure and minimize an external heating of the coils. The maximum magnetic field strength is 3 T and 2 T in injection and extraction region respectively. For the radial plasma confinement a hexapole made of NdFeB permanent magnet is used. The source will be capable of ECR plasma heating using different frequencies (14 GHz or 18 GHz). To be able to deliver usable intensities of solids, the design is also allow axial access for evaporation oven and metal samples using the plasma sputtering technique. Very preliminary results of the source test are presented.

  12. Parallel Guided Local Search and Some Preliminary Experimental Results for Continuous Optimization

    Directory of Open Access Journals (Sweden)

    Nasser Tairan

    2014-02-01

    Full Text Available This paper proposes a Parallel Guided Local Search (PGLS framework for continuous optimization. In PGLS, several guided local search (GLS procedures (agents are run for solving the optimization problem. The agents exchan ge information for speeding up the search. For example, the information exchanged could be kno wledge about the landscape obtained by the agents. The proposed algorithm is applied to co ntinuous optimization problems. The preliminary experimental results show that the algo rithm is very promising .

  13. Accelerated stress testing of thin film solar cells: Development of test methods and preliminary results

    Science.gov (United States)

    Lathrop, J. W.

    1985-01-01

    If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.

  14. Characterizing the Experimental Procedure in Science Laboratories: A Preliminary Step towards Students Experimental Design

    Science.gov (United States)

    Girault, Isabelle; d'Ham, Cedric; Ney, Muriel; Sanchez, Eric; Wajeman, Claire

    2012-01-01

    Many studies have stressed students' lack of understanding of experiments in laboratories. Some researchers suggest that if students design all or parts of entire experiment, as part of an inquiry-based approach, it would overcome certain difficulties. It requires that a procedure be written for experimental design. The aim of this paper is to…

  15. Experimental Test Plan DOE Tidal and River Reference Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Neary, Vincent S [ORNL; Hill, Craig [St. Anthony Falls Laboratory, 2 Third Avenue SE, Minneapolis, MN 55414; Chamorro, Leonardo [St. Anthony Falls Laboratory, 2 Third Avenue SE, Minneapolis, MN 55414; Gunawan, Budi [ORNL

    2012-09-01

    Our aim is to provide details of the experimental test plan for scaled model studies in St. Anthony Falls Laboratory (SAFL) Main Channel at the University of Minnesota, including a review of study objectives, descriptions of the turbine models, the experimental set-up, instrumentation details, instrument measurement uncertainty, anticipated experimental test cases, post-processing methods, and data archiving for model developers.

  16. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  17. Hazards by shock waves during explosive eruptions: preliminary results of experimental investigations.

    Science.gov (United States)

    Scolamacchia, Teresa; Alatorre Ibarguengoïtia, Miguel; Spieler, Oliver; Dingwell, Donald B.

    2010-05-01

    A recent study (Scolamacchia and Shouwenaars, 2009) investigated the nature of microscopic craters on the steel surface of a basketball pole left standing in one of the villages destroyed by the 1982 eruption of El Chichón volcano. The craters were attributed to the impacts of ash particles (70-280 μm) accelerated by shock waves due to an efficient momentum coupling with a gas phase, such that a sudden expansion of the gas, caused by shock wave propagation, drag the particles up to speeds of 710 to 980 m/s. Several open questions existed on this kind of phenomena. Preliminary tests were performed to investigate the correlation between particle size and the high velocities calculated, based on inner deformation of the steel and crater geometry. We used a shock tube apparatus consisting of a high-pressure (HP) steel autoclave, pressurized with Ar gas, and a low pressure (LP) tank at atmospheric conditions. We used ash and lapilli bulk samples from El Chichón trachyandesites, and lapilli with random irregular shapes obtained by crushing and abrading dacitic blocks from pyroclastic flow deposits of Unzen volcano. The samples were placed inside an autoclave at ambient T and P, located between the HP autoclave and the LP tank. Steel plates (same type of the original impacted material), were fixed to the LP tank walls, 10 cm above the autoclave that contained the samples. Shock waves were generated by the sudden decompression of the Ar gas due to the systematical failure of a diaphragm (which separate the LP from the HP section). Air expansion accelerated the particles from below toward the steel plate. The speed of the particles was measured using a system of 4 copper wires conducting an electric signal. The signals dropped when the particles reached the wires. We used low pressure ranges (3.1 to 9.8 MPa) for all experimental runs, obtaining a range of particles velocities between 40 and 257 m/s. These velocities can be attained by pyroclastic density currents. Higher

  18. Take Home Tests: An Experimental Study.

    Science.gov (United States)

    Weber, Larry J.; And Others

    1983-01-01

    Data gathered on three kinds of tests (closed-book, open-book, and take-home) covered possible differential achievement on knowledge and cognitive-skill items, student attitudes, and cheating. On take-home tests, scores on knowledge items were found to higher, anxiety level was lower, and cheating was not a problem. (MSE)

  19. Preliminary test results from the CELSS Test Facility Engineering Development Unit

    Science.gov (United States)

    Kliss, Mark H.; Macelroy, R. D.; Blackwell, C. C.; Borchers, B. A.; Drews, M. E.; Longabaugh, J. R.; Yendler, B. S.; Zografos, A. I.

    1994-01-01

    As part of the NASA Controlled Ecological Life Support System (CELSS) Program, a CELSS Test Facility (CTF) is being planned for installation on the Space Station. The CTF will be used to provide data on the productivity and efficiency of a variety of CELSS higher plant crops grown in the microgravity environment of the Space Station. Tight environmental control will be maintained while data on gas exchange rates and biomass accumulation rates are collected. In order to obtain an early realistic determination of the subsystem and system requirements necessary to provide the environmental conditions specified for CTF crop productivity experiments, an Engineering Development Unit (EDU) has been designed, constructed and is in the process of subsystem and system testing at NASA Ames Research Center. The EDU is a ground test-bed which will be used to characterize the integrated performance of major subsystem technologies, to evaluate hardware candidates and control strategies required for the CTF, and to further define the ability to meet CTF requirements within present Space Station constraints. This paper reviews the functional requirements for the EDU, and focuses on the performance evaluation and test results of the various subsystems. Preliminary integrated performance results and control system operation are addressed, and plans for future science and technology testing are discussed.

  20. Preliminary Results on the Experimental Investigation of the Structure Functions of Bound Nucleons

    Energy Technology Data Exchange (ETDEWEB)

    Bodek, Arie [Univ. of Rochester, NY (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-08-01

    We present preliminary results on an experimental study of the nuclear modification of the longitudinal ($\\sigma_L$) and transverse ($\\sigma_T$) structure functions of nucleons bound in nuclear targets. The origin of these modifications (commonly referred as as the EMC effect) is not fully understood. Our measurements of R= $\\sigma_L / \\sigma_T$ for nuclei ($R_A$) and for deuterium ($R_D$) indicate that nuclear modifications of the structure functions of bound nucleons are different for the longitudinal and transverse structure functions, and that contrary to expectation from several theoretical models, $R_A< R_D$.

  1. Preliminary Results on the Experimental Investigation of the Structure Functions of Bound Nucleons

    CERN Document Server

    Bodek, A

    2015-01-01

    We present preliminary results on an experimental study of the nuclear modification of the longitudinal ($\\sigma_L$) and transverse ($\\sigma_T$) structure functions of nucleons bound in nuclear targets. The origin of these modifications (commonly referred as as the EMC effect) is not fully understood. Our measurements of R= $\\sigma_L / \\sigma_T$ for nuclei ($R_A$) and for deuterium ($R_D$) indicate that nuclear modifications of the structure functions of bound nucleons are different for the longitudinal and transverse structure functions, and that contrary to expectation from several theoretical models, $R_A< R_D$.

  2. Preliminary Experimental Results for Indirect Vector-Control of Induction Motor Drives with Forced Dynamics

    Directory of Open Access Journals (Sweden)

    Jan Vittek

    2003-01-01

    Full Text Available The contribution presents an extension of indirect vector control of electric drives employing induction motors to 'Forced Dynamic Control'. This method of control offers an accurate realisation of dynamic response profiles, which can be selected by the user. The developed system can be integrated into a drive with a shaft position encoder or a shaft sensoriess drive, in which only the stator currents are measured. The applied stator voltages are determined by a computed inverter switching algorithm. Simulation results and preliminary experimental results for indirect vector control of an idle running induction motor indicate good agreement with the theoretical predictions.

  3. Experimental artefacts in undrained triaxial testing

    CERN Document Server

    Ghabezloo, Siavash

    2010-01-01

    For evaluation of the undrained thermo-poro-elastic properties of saturated porous materials in conventional triaxial cells, it is important to take into account the effect of the dead volume of the drainage system. The compressibility and the thermal expansion of the drainage system along with the dead volume of the fluid filling this system, influence the measured pore pressure and volumetric strain during undrained thermal or mechanical loading in a triaxial cell. A correction method is presented in this paper to correct these effects during an undrained isotropic compression test or an undrained heating test. A parametric study has demonstrated that the porosity and the drained compressibility of the tested material and the ratio of the vol-ume of the drainage system to the one of the tested sample are the key parameters which influence the most the error induced on the measurements by the drainage system.

  4. Experimental Tests of Particle Flow Calorimetry

    CERN Document Server

    Sefkow, Felix; Kawagoe, Kiyotomo; Pöschl, Roman; Repond, José

    2015-01-01

    Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\\&D, mainly conducted within the CALICE collaboration, for this novel type of detector. The performance of large scale prototypes in beam tests validate the technical concept of particle flow calorimeters. The comparison of test beam data with simulation, of e.g.\\ hadronic showers, supports full detector studies and gives deeper insight into the structure of hadronic cascades than was possible previously.

  5. Experimental design for drifting buoy Lagrangian test

    Science.gov (United States)

    Saunders, P. M.

    1975-01-01

    A test of instrumentation fabricated to measure the performance of a free drifting buoy as a (Lagrangian) current meter is described. Specifically it is proposed to distinguish between the trajectory of a drogued buoy and the trajectory of the water at the level of the drogue by measuring the flow relative to the drogue.

  6. Career concerns incentives: An experimental test

    DEFF Research Database (Denmark)

    Koch, Alexander; Morgenstern, Albrecht; Raab, Philippe

    Holmström's (1982/99) career concerns model has become a workhorse for analyzing agency issues in many fields. The underlying signal jamming argument requires players to use information in a Bayesian way, which is difficult to directly test with field data: typically little is known about...

  7. Description and Preliminary Testing of the CDSN Seismic Sensor Systems

    Science.gov (United States)

    Peterson, Jon; Tilgner, Edwin E.

    1985-01-01

    INTRODUCTION The China Digital Seismograph Network (CDSN) is being designed and installed to provide the People's Republic of China with the facilities needed to create a national digital database for earthquake research. The CDSN, which is being developed jointly by the PRC State Seismological Bureau and the U.S. Geological Survey, will consist initially of nine digitally-recording seismograph stations, a data management system to be used for compiling network-day tapes, and a depot maintenance center. Data produced by the network will be shared with research scientists throughout the world. A national seismograph network must be designed to support a variety of research objectives. From this standpoint, the choices and tradeoffs involved in specifying signal bandwidth, resolution, and dynamic range are the most important decisions in system design. As in the case of the CDSN, these decisions are made during the selection and design of the seismic sensor system and encoder components. The purpose of this report is to describe the CDSN sensor systems, their important signal characteristics, and the results of preliminary tests that have been performed on the instruments. Four overlapping data bands will be recorded at each station: short period (SP), broadband (BB), long period (LP), and very long period (VLP). Amplitude response curves are illustrated in Figure I. Vertical and horizontal components will be recorded for each data band. The SP and LP channels will be recorded with sufficient sensitivities to resolve earth background noise at seismically quiet sites. The BB channels will have a lower sensitivity and are intended for broadband recording of moderate-to-large body-wave signals and for increasing the effective amplitude range in the short- and long-period bands. The VLP channel does not provide additional spectral coverage at long periods; its purpose is to make use of on-site filtration and decimation to reduce post processing requirements for VLP

  8. Career concerns incentives: An experimental test

    DEFF Research Database (Denmark)

    Koch, Alexander; Morgenstern, Albrecht; Raab, Philippe

    2009-01-01

    Holmström's (1982/99) career concerns model has become a workhorse for analyzing agency issues in many elds. The underlying signal jamming argument requires players to use information in a Bayesian way, which is difficult to directly test with eld data: typically little is known about the informa......Holmström's (1982/99) career concerns model has become a workhorse for analyzing agency issues in many elds. The underlying signal jamming argument requires players to use information in a Bayesian way, which is difficult to directly test with eld data: typically little is known about...... the information that individuals base their decisions on. Our laboratory experiment provides prima facie evidence: i) the signal jamming mechanism successfully creates incentives on the labor supply side; ii) decision errors take time to decrease; iii) while subjects’ average beliefs are remarkably consistent...

  9. Recent experimental progresses in testing Quantum Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Brida, Giorgio; Genovese, Marco; Piacentini, Fabrizio, E-mail: m.genovese@inrim.it [INRIM, strada delle Cacce 91, 10135 Torino (Italy)

    2011-07-08

    In this paper we will show some recent experiments performed in the 'Carlo Novero' labs of the Optics Division of the National Institute of Metrological Research (INRIM, Torino, Italy), in order to discriminate between Standard Quantum Mechanics and some specific, restricted class of Hidden Variable Theories (HVTs). The first experiment will be on the testing of two restricted Local Realistic Theories (LRTs), properly built to describe polarization entangled photons experiments, whose inequalities are not affected by the detection loophole. The second and third experiments instead will perform the Alicki - Van Ryn non-classicality test on single particles, by means of two different setups based on heralded single photon sources.

  10. Preliminary experimental investigation of an X-band Cerenkov-type high power microwave oscillator without guiding magnetic field

    Science.gov (United States)

    Guo, Liming; Shu, Ting; Li, Zhiqiang; Ju, Jinchuan; Fang, Xiaoting

    2017-02-01

    Among high power microwave (HPM) generators without guiding magnetic field, Cerenkov-type oscillator is expected to achieve a relatively high efficiency, which has already been realized in X-band in our previous simulation work. This paper presents the preliminary experimental investigations into an X-band Cerenkov-type HPM oscillator without guiding magnetic field. Based on the previous simulation structure, some modifications regarding diode structure were made. Different cathode structures and materials were tested in the experiments. By using a ring-shaped graphite cathode, microwave of about one hundred megawatt level was generated with a pure center frequency of 9.14 GHz, and an efficiency of about 1.3%. As analyzed in the paper, some practical issues reduce the efficiency in experiments, such as real features of the electron beam, probable breakdown regions on the cathode surface which can damage the diode, and so forth.

  11. Career concerns incentives: An experimental test

    DEFF Research Database (Denmark)

    Koch, Alexander; Morgenstern, Albrecht; Raab, Philippe

    Holmström's (1982/99) career concerns model has become a workhorse for analyzing agency issues in many fields. The underlying signal jamming argument requires players to use information in a Bayesian way, which is difficult to directly test with field data: typically little is known about...... the information that individuals base their decisions on. Our laboratory experiment provides prima facie evidence: i) the signal jamming mechanism successfully creates incentives on the labor supply side; ii) decision errors take time to decrease; iii) while subjects' average beliefs are remarkably consistent...

  12. Experimental testing of a new solar dryer

    Energy Technology Data Exchange (ETDEWEB)

    Tiris, Cigdem; Ozbalta, Necdet (Ege Univ., Izmir (Turkey). Solar Energy Inst.); Tiris, Mustafa; Dincer, Ibrahim (TUBITAK, Kocaeli (Turkey). Marmara Research Center)

    1994-06-01

    Drying of agricultural products is an energy-intensive operation. High prices and shortages in fossil fuels increase the emphasis on using solar energy as an alternative energy source, especially in developing countries. In this respect, a new solar dryer, which consisted of a solar air heater and a drying chamber, was developed and used for drying various fruits and vegetables, i.e. sultana grapes, green beans, sweet peppers and chili peppers and was successfully tested. In order to make a comparison, the traditional sun-drying experiments were employed. Results showed that the solar dryer reduced the drying time significantly and prevented mass losses, and essentially provided better product quality. (author)

  13. Experimentally testing the standard cosmological model

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, D.N. (Chicago Univ., IL (USA) Fermi National Accelerator Lab., Batavia, IL (USA))

    1990-11-01

    The standard model of cosmology, the big bang, is now being tested and confirmed to remarkable accuracy. Recent high precision measurements relate to the microwave background; and big bang nucleosynthesis. This paper focuses on the latter since that relates more directly to high energy experiments. In particular, the recent LEP (and SLC) results on the number of neutrinos are discussed as a positive laboratory test of the standard cosmology scenario. Discussion is presented on the improved light element observational data as well as the improved neutron lifetime data. alternate nucleosynthesis scenarios of decaying matter or of quark-hadron induced inhomogeneities are discussed. It is shown that when these scenarios are made to fit the observed abundances accurately, the resulting conclusions on the baryonic density relative to the critical density, {Omega}{sub b}, remain approximately the same as in the standard homogeneous case, thus, adding to the robustness of the standard model conclusion that {Omega}{sub b} {approximately} 0.06. This latter point is the deriving force behind the need for non-baryonic dark matter (assuming {Omega}{sub total} = 1) and the need for dark baryonic matter, since {Omega}{sub visible} < {Omega}{sub b}. Recent accelerator constraints on non-baryonic matter are discussed, showing that any massive cold dark matter candidate must now have a mass M{sub x} {approx gt} 20 GeV and an interaction weaker than the Z{sup 0} coupling to a neutrino. It is also noted that recent hints regarding the solar neutrino experiments coupled with the see-saw model for {nu}-masses may imply that the {nu}{sub {tau}} is a good hot dark matter candidate. 73 refs., 5 figs.

  14. Preliminary Test Estimators and Phi-divergence Measures in Pooling Binomial Data

    Directory of Open Access Journals (Sweden)

    N. Martin

    2012-07-01

    Full Text Available Two independent random samples are drawn from two Binomial populations with parameters theta1 and  theta2 respectively. Ahmed (1991 considered a preliminary test estimator based on maximum likelihood estimator for estimating theta1 when it is suspected that theta1=theta2.  In this paper we combine minimum phi-divergence estimators as well as phi-divergence test statistics in order to define a preliminary phi-divergence test estimators. These new estimators are compared with the classical estimator as well as the pooled estimator.

  15. Preliminary Options Assessment of Versatile Irradiation Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ramazan Sonat [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    The objective of this report is to summarize the work undertaken at INL from April 2016 to January 2017 and aimed at analyzing some options for designing and building a versatile test reactor; the scope of work was agreed upon with DOE-NE. Section 2 presents some results related to KNK II and PRISM Mod A. Section 3 presents some alternatives to the VCTR presented in [ ] as well as a neutronic parametric study to assess the minimum power requirement needed for a 235U metal fueled fast test reactor capable to generate a fast (>100 keV) flux of 4.0 x 1015 n /cm2-s at the test location. Section 4 presents some results regarding a fundamental characteristic of test reactors, namely displacement per atom (dpa) in test samples. Section 5 presents the INL assessment of the ANL fast test reactor design FASTER. Section 6 presents a summary.

  16. Study of fast reactor safety test facilities. Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Bell, G.I.; Boudreau, J.E.; McLaughlin, T.; Palmer, R.G.; Starkovich, V.; Stein, W.E.; Stevenson, M.G.; Yarnell, Y.L.

    1975-05-01

    Included are sections dealing with the following topics: (1) perspective and philosophy of fast reactor safety analysis; (2) status of accident analysis and experimental needs; (3) experiment and facility definitions; (4) existing in-pile facilities; (5) new facility options; and (6) data acquisition methods. (DG)

  17. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  18. China ADS sub-critical experimental assembly-Venus-1 and preliminary experiment

    Institute of Scientific and Technical Information of China (English)

    SHI Yongqian; ZHANG Wei; CAO Jian; QUAN Yanhui; LUO Huangda; WU Xiaofei; XIA Pu; LUO Zhanglin; ZHAO Zhixiang; DING Dazhao; LI Yiguo; ZHU Qinfu; XIA Haihong; LI Jien

    2007-01-01

    China's accelerator-driven sub-critical system (ADS) sub-critical experimental assembly--Venus-1 and the preliminary experiment is presented. The core of Venus-1 is a coupled one of a fast neutron zone and a thermal neutron zone. The fast neutron zone is at the centre of the core and formed by natural uranium fuel. A fast neutron spectrum field can be produced in the fast neutron zone and used for the transmutation of minor actinides (Mas). The thermal neutron zone surrounds the fast neutron zone and is formed by low-enriched uranium fuel. It is a fission zone. An epithermal neutron zone between the fast neutron zone and the thermal neutron zone can be established for the transmutation of longlived fission products (LLFP). On July 18, 2005, the first fuel element was loaded into the Venus-Ⅰ sub-critical assembly and some preliminary experiments about the subcritical neutronics were performed. The Venus-1 can be driven by an Am-Be source or other steady neutron source (Cf-252, D-D reaction and D-T reaction) to study the effect of the external neutron source with different energies or a D-T pulsed neutron source on the dynamic characteristics.

  19. Study on critical heat flux in narrow rectangular channel with repeated-rib roughness. 1. Experimental facility and preliminary experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Hidetaka; Terada, Atsuhiko; Kaminaga, Masanori; Hino, Ryutaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-10-01

    In the design of a spallation target system, the water cooling system, for example a proton beam window and a safety hull, is used with narrow channels, in order to remove high heat flux and prevent lowering of system performance by absorption of neutron. And in narrow channel, heat transfer enhancement using 2-D rib is considered for reduction the cost of cooling component and decrease inventory of water in the cooling system, that is, decrease of the amount of irradiated water. But few studies on CHF with rib have been carried out. Experimental and analytical studies with rib-roughened test section, in 10:1 ratio of pitch to height, are being carried out in order to clarify the CHF in rib-roughened channel. This paper presents the review of previous researches on heat transfer in channel with rib roughness, overview of the test facility and the preliminary experimental and analytical results. As a result, wall friction factors were about 3 times as large as that of smooth channel, and heat transfer coefficients are about 2 times as large as that of smooth channel. The obtained CHF was as same as previous mechanistic model by Sudo. (author)

  20. Interteaching and the Testing Effect: A Preliminary Analysis

    Science.gov (United States)

    Lambert, Tonya; Saville, Bryan K.

    2012-01-01

    In a number of studies, interteaching has produced better student-learning outcomes than traditional teaching methods. Little research, however, has examined ways to make interteaching more effective. Research on the testing effect suggests that frequent testing may improve performance. Thus, including postdiscussion quizzes as a part of…

  1. Preliminary Results on the Experimental Investigation of the Structure Functions of Bound Nucleons

    Energy Technology Data Exchange (ETDEWEB)

    Bodek, Arie [University of Rochester, Rochester, NY

    2015-09-01

    We present preliminary results on an experimental study of the nuclear modification of the longitudinal (σL) and transverse (σT) structure functions of nucleons bound in nuclear targets. The origin of these modifications (commonly referred as as the EMC effect) is not fully understood. Our measurements of R= σLT for nuclei (RA) and for deuterium (RD) indicate that nuclear modifications of the structure functions of bound nucleons are different for the longitudinal and transverse structure functions, and that contrary to expectation from several theoretical models, RA < RD.

  2. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová Lenka; Petrů, Jana; Ivo HLAVATÝ; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  3. Preliminary evaluation of an experimental clinical chemistry analyzer developed for space medicine.

    Science.gov (United States)

    Wu, A H; Gornet, T G; Schenkel, O; Smith-Cronin, L; Graham, G A; Tonnesen, A S; McKinley, B A

    1993-01-01

    An experimental clinical chemistry analyzer system was designed and built to demonstrate the feasibility of clinical chemistry as part of a medical-care system at NASA's planned space station Freedom. We report the performance of the experimental analyzer, called a medical development unit (MDU), for selected analytes in a laboratory setting in preparation for a preliminary clinical trial at patients' bedsides in an intensive-care unit. Within-run CVs ranged from 0.7% for sodium to 7.1% for phosphorus; day-to-day CVs ranged from 1.0% for chloride to 23.4% for calcium. Correlation of patients' blood sample analyses compared well with those by Ektachem E700 and other high-volume central laboratory analyzers (r ranged from 0.933 for creatine kinase MB isoenzyme to 0.997 for potassium), except for hemoglobin (r = 0.901) and calcium (r = 0.823). Although several CVs obtained in this study exceeded theoretical desired precision limits based on biological variations, performance was adequate for clinical laboratory diagnosis. We examined the effect of potentially interfering concentrations of hemoglobin, bilirubin, and lipids: the only effect was negative interference with calcium analyses by high concentrations of bilirubin. We also examined the effects of preanalytical variables and the performance of experimental sample-transfer cups designed to retain sample and reference liquid in microgravity. Continued development of the MDU system is recommended, especially automation of sample processing.

  4. Preliminary test of effects of cognitive ability, experience, and teaching methods on Verbal Analogy Test scores.

    Science.gov (United States)

    Rosenberg, D; Willson-Quayle, A; Pasnak, R

    2000-06-01

    The methods from which one can choose when preparing for the GRE Verbal Analogies include books, software, audiotapes, and formal classroom instruction. What teaching method will work best for a given individual? To begin the search for an answer, Gray's test of reasoning ability was given to 28 undergraduates who also answered a questionnaire detailing their experience with analogies. They were randomly assigned to teaching conditions ranging from self-directed workbook study to intensive interactive assistance. No teaching method was superior overall, but interactions showed that (1) students who scored worst on the pretest improved the most, (2) those higher in cognitive functioning and experience performed better after intensive interactive assistance, and (3) those lower in both cognitive functioning and experience did significantly better with self-paced workbooks. This preliminary work suggests that it may be profitable to assess the prior experience and reasoning of potential students and adopt the methods for teaching formal operational thought found empirically to be most suitable.

  5. Preliminary low temperature tests of a digital signal processor

    Science.gov (United States)

    Zebulum, Ricardo S.; Ramesham, Rajeshuni; Stoica, Adrian; Keymeulen, Didier; Daud, Taher; Sekanina, Lukas

    2005-01-01

    This paper describes an initial experiment performed to assess the electrical behavior of the Innovative Integration board containing a Digital Signal Processor (DSP) with its JTAG (Blackhawk) connector at low temperatures. The objective of the experiment is to determine the lowest temperature at which the DSP can operate. The DSP was tested at various low-temperatures and a Genetic Algorithm was used as the DSP test program.

  6. CHALLENGE TESTS WITH LISTERIA MONOCYTOGENES IN SALAMI: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    R. Mioni

    2013-02-01

    Full Text Available Challenge tests are the preferable methodology to study the behaviour of Listeria monocytogenes on ready to eat foods, according to Regulation (EC 2073/2005. Challenge testing using L. monocytogenes in seasoned salami from different food business operators showed, after seasoning of the product, a count reduction of the inoculated organisms without any further growth of the pathogen; however differences of L. monocytogenes behaviour could be observed according to different production protocols.

  7. Nuclear Test-Experimental Science: Annual report, fiscal year 1988

    Energy Technology Data Exchange (ETDEWEB)

    Struble, G.L.; Donohue, M.L.; Bucciarelli, G.; Hymer, J.D.; Kirvel, R.D.; Middleton, C.; Prono, J.; Reid, S.; Strack, B. (eds.)

    1988-01-01

    Fiscal year 1988 has been a significant, rewarding, and exciting period for Lawrence Livermore National Laboratory's nuclear testing program. It was significant in that the Laboratory's new director chose to focus strongly on the program's activities and to commit to a revitalized emphasis on testing and the experimental science that underlies it. It was rewarding in that revolutionary new measurement techniques were fielded on recent important and highly complicated underground nuclear tests with truly incredible results. And it was exciting in that the sophisticated and fundamental problems of weapons science that are now being addressed experimentally are yielding new challenges and understanding in ways that stimulate and reward the brightest and best of scientists. During FY88 the program was reorganized to emphasize our commitment to experimental science. The name of the program was changed to reflect this commitment, becoming the Nuclear Test-Experimental Science (NTES) Program.

  8. Numerical Modeling and Experimental Testing of a Wave Energy Converter

    DEFF Research Database (Denmark)

    Zurkinden, Andrew Stephen; Kramer, Morten; Ferri, Francesco;

    numerical values for comparison with the experimental test results which were carried out in the same time. It is for this reason why Chapter 4 does consist exclusively of numerical values. Experimental values and measured time series of wave elevations have been used throughout the report in order to a...

  9. Putting Google Scholar to the Test: A Preliminary Study

    Science.gov (United States)

    Robinson, Mary L.; Wusteman, Judith

    2007-01-01

    Purpose: To describe a small-scale quantitative evaluation of the scholarly information search engine, Google Scholar. Design/methodology/approach: Google Scholar's ability to retrieve scholarly information was compared to that of three popular search engines: Ask.com, Google and Yahoo! Test queries were presented to all four search engines and…

  10. On Designing Construct Driven Situational Judgment Tests: Some Preliminary Recommendations

    Science.gov (United States)

    Guenole, Nigel; Chernyshenko, Oleksandr S.; Weekly, Jeff

    2017-01-01

    Situational judgment tests (SJTs) are widely agreed to be a measurement technique. It is also widely agreed that SJTs are a questionable methodological choice for measurement of psychological constructs, such as behavioral competencies, due to a lack of evidence supporting appropriate factor structures and high internal consistencies.…

  11. Modeling and Testing of EVs - Preliminary Study and Laboratory Development

    DEFF Research Database (Denmark)

    Yang, Guang-Ya; Marra, Francesco; Nielsen, Arne Hejde;

    2010-01-01

    Electric vehicles (EVs) are expected to play a key role in the future energy management system to stabilize both supply and consumption with the presence of high penetration of renewable generation. A reasonably accurate model of battery is a key element for the study of EVs behavior and the grid...... tests, followed by the suggestions towards a feasible battery model for further studies....

  12. Preliminary tests of a damaged ship for CFD validation

    Directory of Open Access Journals (Sweden)

    Sungkyun Lee

    2012-06-01

    Full Text Available One of the most critical issues in naval architecture these days is the operational safety. Among many factors to be considered for higher safety level requirements, the hull stability in intact and damaged conditions is the first to ensure for both commercial and military vessels. Unlike the intact stability cases, the assessment of the damaged ship stability is very complicated physical phenomena. Therefore it is widely acknowledged that computational fluid dynamics (CFD methods are one of most feasible approaches. In order to develop better CFD methods for damaged ship stability assessment, it is essential to perform well-designed model tests and to build a database for CFD validation. In the present study, free roll decay tests in calm water with both intact and damaged ships were performed and six degree-of-freedom (6DOF motion responses of intact ship in regular waves were measured. Through the free roll decay tests, the effects of the flooding water on the roll decay motion of a ship were investigated. Through the model tests in regular waves, the database that provides 6DOF motion responses of intact ship was established.

  13. Study and Preliminary Analysis of Test of Aerosol Migration Mechanism

    Institute of Scientific and Technical Information of China (English)

    CHEN; Lin-lin; SUN; Xue-ting; WEI; Yan-song

    2015-01-01

    TAMM(test of aerosol migration mechanism)is one of the important aspects of Studies on Migration Mechanism of the Source Term under Severe Accident,which is a significant research of the National Large Advanced PWR Research Program.The main task researches the

  14. Preliminary Results of Breakwater Round-Head Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1995-01-01

    The rational design diagram for Dolos armour should incorporate both the hydraulic stability and the structural integrity. The previous tests performed by Aalborg University (AU) made available such design diagram for the trunk of Dolos breakwater without superstructures (Burcharth et al. 1992...

  15. In vitro tests to evaluate immunotoxicity: A preliminary study.

    NARCIS (Netherlands)

    Carfi', M; Gennari, A; Malerba, I; Corsini, E; Pallardy, M; Pieters, R; Loveren, Henk van; Vohr, H W; Hartung, T; Gribaldo, L

    2007-01-01

    The implementation of Registration, Evaluation and Authorisation of new and existing Chemicals (REACH) will increase the number of laboratory animals used, if alternative methods will not be available. In the meantime, REACH promotes the use of in vitro tests and, therefore, a set of appropriated al

  16. Semantic Verbal Fluency test in dementia: Preliminary retrospective analysis

    Directory of Open Access Journals (Sweden)

    Marcos Lopes

    Full Text Available Abstract The Semantic Verbal Fluency (SVF test entails the generation of words from a given category within a pre-set time of 60 seconds. Objectives: To verify whether socio-demographic and clinical data of individuals with dementia correlate with the performance on the SVF test and to ascertain whether differences among the criteria of number of answers, clusters and data spread over the intervals, predict clinical results. Methods: This was a retrospective study of 49 charts of demented patients classified according to the Clinical Dementia Rating (CDR scale. We correlated education, age and gender, as well as CDR and Mini-Mental State Exam (MMSE scores with the number of answers, clustering and switching distributed over four 15-second intervals on the SVF test. Results: The correlation between number of answers and quartiles was weak (r=0.407, p=0.004; r=0.484, p<0.001 but correlation between the number of clusters and responses was strong (r=0.883, p<0.001. The number of items on the SVF was statistically significant with MMSE score (p=0.01 and there was a tendency for significance on the CDR (p=0.06. The results indicated little activity regarding what we propose to call cluster recalling in the two groups. Discussion: The SVF test, using number of items generated, was found to be more effective than classic screening tests in terms of speed and ease of application in patients with CDR 2 and 3.

  17. A soft wearable robot for the shoulder: Design, characterization, and preliminary testing.

    Science.gov (United States)

    O'Neill, Ciaran T; Phipps, Nathan S; Cappello, Leonardo; Paganoni, Sabrina; Walsh, Conor J

    2017-07-01

    In this paper, we present a soft wearable robot for the shoulder which has the potential to assist individuals suffering from a range of neuromuscular conditions affecting the shoulder to perform activities of daily living. This wearable robot combines two types of soft textile pneumatic actuators which were custom developed for this particular application to support the upper arm through shoulder abduction and horizontal flexion/extension. The advantage of a textile-based approach is that the robot can be lightweight, low-profile, comfortable and non-restrictive to the wearer, and easy to don like an item of clothing. The actuator's ability to fold flat when not in use allows the robot to be almost invisible under clothing, potentially allowing the user to avoid any stigma associated with using assistive devices in public. To abduct the arm, a textilebased pneumatic actuator was developed to fit within the axilla to push the arm upwards, while a pair of smaller actuators pivot the abduction actuator to allow for horizontal extension and flexion. The individual textile actuators were experimentally evaluated before being integrated into a wearable garment. Human subject testing was performed to evaluate the ability of the robot to assist the arm by monitoring changes in biological muscle activity when comparing the robot powered on and off. Preliminary results show large reductions in muscular effort in targeted muscles, demonstrating the feasibility and promise of such a soft wearable robot for the shoulder.

  18. Flight Test 4 Preliminary Results: NASA Ames SSI

    Science.gov (United States)

    Isaacson, Doug; Gong, Chester; Reardon, Scott; Santiago, Confesor

    2016-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements as well as the safety substantiation and end-to-end assessment of DAA system performance. The Unmanned Aircraft System (UAS) Integration into the National Airspace System (NAS) Project conducted flight test program, referred to as Flight Test 4, at Armstrong Flight Research Center from April -June 2016. Part of the test flights were dedicated to the NASA Ames-developed Detect and Avoid (DAA) System referred to as JADEM (Java Architecture for DAA Extensibility and Modeling). The encounter scenarios, which involved NASA's Ikhana UAS and a manned intruder aircraft, were designed to collect data on DAA system performance in real-world conditions and uncertainties with four different surveillance sensor systems. Flight test 4 has four objectives: (1) validate DAA requirements in stressing cases that drive MOPS requirements, including: high-speed cooperative intruder, low-speed non-cooperative intruder, high vertical closure rate encounter, and Mode CS-only intruder (i.e. without ADS-B), (2) validate TCASDAA alerting and guidance interoperability concept in the presence of realistic sensor, tracking and navigational errors and in multiple-intruder encounters against both cooperative and non-cooperative intruders, (3) validate Well Clear Recovery guidance in the presence of realistic sensor, tracking and navigational errors, and (4) validate DAA alerting and guidance requirements in the presence of realistic sensor, tracking and navigational errors. The results will be

  19. Small-scale experimental tests of tandem mirror machines with thermal barriers

    Energy Technology Data Exchange (ETDEWEB)

    Drake, R.P.

    1979-09-01

    A summary is given of current physical understanding of tandem mirrors with thermal barriers. Physicists who understand tandem mirrors can use this document as a preliminary guide to the physical issues and experimental problems involved. This report will focus upon the issues that can be tested experimentally, and on the areas needing experimental and theoretical inventions. The next section discusses the plasma potentials and plasma confinement which correspond to a tandem mirror with thermal barriers, assuming the barriers exist in steady-state. The creation of a barrier is discussed, i.e., the natural tendency of the barrier cell to fill with plasma must be countered by pumping ions out of the barrier. The design of a barrier-pumping experiment for TMX is described.

  20. Preliminary Analysis of the Transient Reactor Test Facility (TREAT) with PROTEUS

    Energy Technology Data Exchange (ETDEWEB)

    Connaway, H. M. [Argonne National Lab. (ANL), Argonne, IL (United States); Lee, C. H. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-11-30

    The neutron transport code PROTEUS has been used to perform preliminary simulations of the Transient Reactor Test Facility (TREAT). TREAT is an experimental reactor designed for the testing of nuclear fuels and other materials under transient conditions. It operated from 1959 to 1994, when it was placed on non-operational standby. The restart of TREAT to support the U.S. Department of Energy’s resumption of transient testing is currently underway. Both single assembly and assembly-homogenized full core models have been evaluated. Simulations were performed using a historic set of WIMS-ANL-generated cross-sections as well as a new set of Serpent-generated cross-sections. To support this work, further analyses were also performed using additional codes in order to investigate particular aspects of TREAT modeling. DIF3D and the Monte-Carlo codes MCNP and Serpent were utilized in these studies. MCNP and Serpent were used to evaluate the effect of geometry homogenization on the simulation results and to support code-to-code comparisons. New meshes for the PROTEUS simulations were created using the CUBIT toolkit, with additional meshes generated via conversion of selected DIF3D models to support code-to-code verifications. All current analyses have focused on code-to-code verifications, with additional verification and validation studies planned. The analysis of TREAT with PROTEUS-SN is an ongoing project. This report documents the studies that have been performed thus far, and highlights key challenges to address in future work.

  1. Impulsivity in Multiplayer Online Battle Arena Gamers: Preliminary Results on Experimental and Self-Report Measures.

    Science.gov (United States)

    Nuyens, Filip; Deleuze, Jory; Maurage, Pierre; Griffiths, Mark D; Kuss, Daria J; Billieux, Joël

    2016-06-01

    Background and aims Multiplayer Online Battle Arena (MOBA) games have become the most popular type of video games played worldwide, superseding the playing of Massively Multiplayer Online Role-Playing Games and First-Person Shooter games. However, empirical studies focusing on the use and abuse of MOBA games are still very limited, particularly regarding impulsivity, which is an indicator of addictive states but has not yet been explored in MOBA games. In this context, the objective of the present study is to explore the associations between impulsivity and symptoms of addictive use of MOBA games in a sample of highly involved League of Legends (LoL, currently the most popular MOBA game) gamers. Methods Thirty-six LoL gamers were recruited and completed both experimental (Single Key Impulsivity Paradigm) and self-reported impulsivity assessments (s-UPPS-P Impulsive Behavior Scale, Barratt Impulsiveness Scale), in addition to an assessment of problematic video game use (Problematic Online Gaming Questionnaire). Results Results showed links between impulsivity-related constructs and signs of excessive MOBA game involvement. Findings indicated that impaired ability to postpone rewards in an experimental laboratory task was strongly related to problematic patterns of MOBA game involvement. Although less consistent, several associations were also found between self-reported impulsivity traits and signs of excessive MOBA game involvement. Conclusions Despite these results are preliminary and based upon a small (self-selected) sample, the present study highlights potential psychological factors related to the addictive use of MOBA games.

  2. Design concept and preliminary experimental demonstration of MEMS gyroscopes with 4-DOF master-slave architecture

    Science.gov (United States)

    Acar, Cenk; Shkel, Andrei M.

    2002-07-01

    This paper reports a design concept for MEMS gyroscopes that shifts the complexity of the design from control architecture to system dynamics, utilizing the passive disturbance rejection capability of the 4-DOF dynamical system. Specifically, a novel wide-bandwidth micromachined gyroscope design approach based on increasing the degrees-of-freedom of the oscillatory system by the use of two independently oscillating interconnected proof masses is presented along with preliminary experimental demonstration of implementation feasibility. With the concept of using a 4-DOF system, inherent disturbance rejection is achieved due to the wide operation frequency range of the dynamic system, providing reduced sensitivity to structural and thermal parameter fluctuations. Thus, less demanding active control strategies are required for operation under presence of perturbations. The fabricated prototype dual-mass gyroscopes successfully demonstrated a dramatically wide driving frequency range within where the drive direction oscillation amplitude varies insignificantly without any active control, in contrast to the conventional gyroscopes where the mass has to be sustained in constant amplitude oscillation in a very narrow frequency band. Mechanical amplification of driven mass oscillation by the sensing element was also experimentally demonstrated, providing large oscillation amplitudes, which is crucial for sensor performance.

  3. Experimental method and preliminary studies of the passive containment water film evaporation mass transfer

    Energy Technology Data Exchange (ETDEWEB)

    Li, Cheng [State Nuclear Power Technology Research, Beijing (China). Development Center; State Nuclear Power Research Institute, Beijing (China); Yang, Lin; Zhao, Wei; Zhou, Shan; Du, Wangfang; Gao, Zhan; Li, Honegsen [State Nuclear Power Technology Research, Beijing (China). Development Center

    2017-05-15

    For larger containments and higher operation parameters, characteristics of the outside cooling of the PCCS are very important for the analysis on the containment integrity. A preliminary analysis was made and a four-step experimental method was used to numerically analyze the falling water film evaporation for the advanced passive containment. Then, the water flow stability along the outside wall of the containment was studied. The results fit well with those correlations without airflow when the air velocity is less than 5.0 m/s. However, when the air velocity is larger than 5.0 m/s, the influence of the air velocity on the water film will appear and the mean water film thickness will be thicker. Based on the prototype operation parameters, experimental studies were carried and the results were compared with the Dittus-Boelter correlation within the operation ranges. A modification factor was proposed for the conservative application of this correlation for nuclear safety analysis.

  4. Numerical and experimental study of local heat transfer enhancement in helically coiled pipes. Preliminary results.

    Science.gov (United States)

    Bozzoli, F.; Cattani, L.; Rainieri, S.; Zachár, A.

    2015-11-01

    In the last years, the attention of heat transfer equipments manufacturers turned toward helically coiled-tube heat exchangers, especially with regards to applications for viscous and/or particulate products. The recent progress achieved in numerical simulation motivated many research groups to develop numerical models for this kind of apparatuses. These models, intended both to improve the knowledge of the fundamental heat transfer mechanisms in curved geometries and to support the industrial design of this kind of apparatuses, are usually validated throughout the comparison with either theoretical or experimental evidences by considering average heat transfer performances. However, this approach doesn't guarantee that the validated models are able to reproduce local effects in details, which are so important in this kind of non-standard geometries. In the present paper a numerical model of convective heat transfer in coiled tubes for laminar flow regime was formulated and discussed. Its goodness was checked throughout the comparison with the latest experimental outcomes of Bozzoli et al. [1] in terms of convective heat flux distribution along the boundary of the duct, by ensuring the effectiveness of the model also in the description of local behaviours. Although the present paper reports only preliminary results of this simulation/validation process, it could be of interest for the research community because it proposes a novel approach that could be useful to validate many numerical models for nonstandard geometries.

  5. Preliminary operational results of the industrial process heat field tests

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Davenport, R.

    1980-04-01

    There are currently six DOE-funded solar industrial process heat (IPH) field tests which have been operational for one year or longer. These are all low temperature first generation projects which supply heat at temperatures below 100/sup 0/C - three hot water and three hot air. During the 1979 calendar year, personnel from the Solar Energy Research Institute (SERI) visited all of these sites; the performance and cost results obtained for each project and the operational problems encountered at each site are discussed.

  6. EXPERIMENTAL METHODOLOGIES AND PRELIMINARY TRANSFER FACTOR DATA FOR ESTIMATION OF DERMAL EXPOSURES TO PARTICLES

    Science.gov (United States)

    Developmental efforts and experimental data are described that focused on quantifying the transfer of particles on a mass basis from indoor surfaces to human skin. Methods were developed that utilized a common fluorescein-tagged Arizona Test Dust (ATD) as a possible surrogate ...

  7. Preliminary results of the round-robin testing of F82H

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, K.; Yamanouchi, N.; Tohyama, A.

    1996-10-01

    Preliminary results of metallurgical, physical and mechanical properties of low activation ferritic steel F82H (IEA heat) were obtained in the round-robin test in Japan. The properties of IEA heat F82H were almost the same as the original F82H.

  8. Preliminary results of a proficiency testing of industrial CT scanners using small polymer items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Cantatore, Angela; De Chiffre, Leonardo

    2012-01-01

    This work presents preliminary results concerning a proficiency testing for intercomparison of industrial CT scanners. Two audit items, similar to common industrial parts, were selected for circulation. The two items were a single polymer complex geometry part and a simple geometry item made of two...

  9. Preliminary Investigation of the 1991 Medical College Admission Test Factor Structure.

    Science.gov (United States)

    Li, Weichang; Mitchell, Karen J.

    A substantially revised Medical College Admission Test (MCAT) was introduced in spring 1991. The new examination is designed to assess critical thinking skills, basic concepts and problem solving facility in science, and writing skills. This paper reports preliminary findings on the factor structure of the revised MCAT, which consists of four…

  10. Sizing and preliminary hardware testing of solar powered UAV

    Directory of Open Access Journals (Sweden)

    S. Jashnani

    2013-12-01

    Full Text Available Integrating solar energy into modern aircraft technology has been a topic of interest and has received a lot of attention from researchers over the last two decades. A few among the many potential applications of this technology are the possibility of continuous self sustained flight for purposes such as information relay, surveillance and monitoring. This paper discusses the altitude and payload mass, as independent parameters, and their influence on the size and design of the aircraft. To estimate available solar power, two different models have been presented; one for low altitudes and the other for high altitudes. An engineering ground model was built to simulate the power and propulsion system over 24 h of continuous operation. The paper presents data from tests performed till date and lessons learnt while dealing with the construction of the engineering ground model as well as changes that can be made to improve the design.

  11. Experimental Setup for Validation Tests in Arc-Heated Facilities

    OpenAIRE

    Esser, Burkard

    2015-01-01

    This document describes the experimental setup for the thermal verification tests in the frame of the EU FP7 Project THOR. It includes a description of the preparatory work in WP6, in particular the assembly of the test models as well as a detailed description of instrumentation and measurement techniques.

  12. Experimental Testing in the Future Internet PERIMETER Project

    Science.gov (United States)

    Dillon, Eileen; Power, Gemma; Grant, Frances Cleary

    The Future Internet faces many challenges for new Internet architectures, protocols and services requiring early experimentation and testing in large-scale environments. Furthermore, the complexity of the software and technologies running on the Future Internet will require more innovative and different approaches to the testing process. This paper examines these requirements and challenges and demonstrates how they are dealt with in the Telecommunications Software and Systems Group using a case study of the Future Internet project; PERIMETER. Details of the testing and experimental methodologies and the role of testbed activities involved in this Quality of Experience network mobility project to develop and adapt to the needs of the Future Internet are provided. The paper concludes with observations of the further developments and innovations required to achieve an end-to-end solution for experimental testing in PERIMETER, and more generally for other Future Internet projects.

  13. Preliminary Scaling Estimate for Select Small Scale Mixing Demonstration Tests

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.; Fort, James A.; Gauglitz, Phillip A.; Rector, David R.; Schonewill, Philip P.

    2013-09-12

    The Hanford Site double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions’ Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems.

  14. AeroValve Experimental Test Data Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, Mark W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-09-01

    This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

  15. Development of a fault test experimental facility model using Matlab

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Iraci Martinez; Moraes, Davi Almeida, E-mail: martinez@ipen.br, E-mail: dmoraes@dk8.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Fault Test Experimental Facility was developed to simulate a PWR nuclear power plant and is instrumented with temperature, level and pressure sensors. The Fault Test Experimental Facility can be operated to generate normal and fault data, and these failures can be added initially small, and their magnitude being increasing gradually. This work presents the Fault Test Experimental Facility model developed using the Matlab GUIDE (Graphical User Interface Development Environment) toolbox that consists of a set of functions designed to create interfaces in an easy and fast way. The system model is based on the mass and energy inventory balance equations. Physical as well as operational aspects are taken into consideration. The interface layout looks like a process flowchart and the user can set the input variables. Besides the normal operation conditions, there is the possibility to choose a faulty variable from a list. The program also allows the user to set the noise level for the input variables. Using the model, data were generated for different operational conditions, both under normal and fault conditions with different noise levels added to the input variables. Data generated by the model will be compared with Fault Test Experimental Facility data. The Fault Test Experimental Facility theoretical model results will be used for the development of a Monitoring and Fault Detection System. (author)

  16. Some effects of experimental error in fracture testing.

    Science.gov (United States)

    Orange, T. W.

    1973-01-01

    The purpose of this paper is to show the effects of experimental imprecision on the stress intensity factors calculated for various practical specimen types. A general form equation for the stress intensity factor is presented, and a general error equation is derived. The expected error in the stress intensity factor is given in terms of the precision levels of the basic experimental measurements and derivatives of the stress intensity calibration factor. Nine common fracture specimen types are considered, and the sensitivity of the various types to experimental error is illustrated. Some implications for fracture toughness testing and crack growth rate testing are discussed, and methods of analysis are proposed to compensate for the effects of experimental error.

  17. Experimentally measured susceptibility to peer influence and adolescent sexual behavior trajectories: A preliminary study.

    Science.gov (United States)

    Choukas-Bradley, Sophia; Giletta, Matteo; Widman, Laura; Cohen, Geoffrey L; Prinstein, Mitchell J

    2014-09-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat room" paradigm involving "e-confederates" who endorsed sexual risk behaviors. Changes in participants' responses to risk scenarios before versus during the "chat room" were used as a performance-based measure of peer influence susceptibility. Participants reported their perceptions of popular peers' number of sexual intercourse partners at baseline and self-reported their number of sexual intercourse partners at baseline and 6, 12, and 18 months later. Susceptibility was examined as a moderator of the longitudinal association between perceptions of popular peers' number of sexual intercourse partners and trajectories of adolescents' own numbers of partners. High perceptions of the number of popular peers' sexual intercourse partners combined with high peer influence susceptibility predicted steeper longitudinal trajectories of adolescents' number of partners. Results provide novel preliminary evidence regarding the importance of peer influence susceptibility in adolescents' development of sexual behaviors.

  18. [Information Concerning Mean Test Scores for the Graduate Management Admission Test (GMAT), Graduate Record Examinations (GRE), Law School Admission Test (LSAT), Preliminary Scholastic Aptitude Test (PSAT), and Scholastic Aptitude Test (SAT) for the National Commission on Excellence in Education.

    Science.gov (United States)

    Solomon, Robert J.

    Data are provided to the National Commission on Excellence in Education on the Graduate Management Admission Test (GMAT), Graduate Record Examinations (GRE), Law School Admission Test (LSAT), Preliminary Scholastic Aptitude Test (PSAT), and Scholastic Aptitude Test (SAT). Statistics are provided on the following: yearly GMAT mean scores 1965-1966…

  19. Preliminary experimental investigation of a complex dual-band high power microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaoping, E-mail: zhangxiaoping@nudt.edu.cn; Li, Yangmei; Li, Zhiqiang; Zhong, Huihuang; Qian, Baoliang [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

    2015-10-15

    In order to promote the power conversion efficiency of a magnetically insulated transmission line oscillator (MILO) and obtain microwaves in dual bands, an axially extracted C-band virtual cathode oscillator (VCO) with multiple resonant cavities is introduced to partially utilize the load current of an S-band MILO. The formed novel dual-band high power microwave source called MILO and VCO is investigated with simulation and experimentally. A dual-band radiation antenna is designed to effectively radiate microwaves generated by the MILO and the VCO, respectively, while avoiding them being influenced by the microwave reflection and diffraction. The preliminary experimental results measured by the dual-band diagnostic system show that both the MILO and the VCO operate normally under repeated shots. A microwave of 2.1 GHz, 1.70 GW is generated from the MILO and a 0.37 GW microwave at frequencies of 4.1 GHz and 3.8 GHz is generated from the VCO under the condition of about 440 kV and 35 kA. Compared with a single MILO (10.6%), a MILO and VCO achieves higher total power and efficiency (13.4%) in both S and C bands, indicating that the load current of the MILO partially couples into the beam-wave interaction in the VCO and then contributes to the output microwaves. However, more works are needed regarding the spectrum purification of the VCO and promotion of the output power of both the MILO and the VCO.

  20. Thermo-mechanical test rig for experimental evaluation of thermal conductivity of ceramic pebble beds

    Energy Technology Data Exchange (ETDEWEB)

    Lo Frano, Rosa, E-mail: rosa.lofrano@ing.unipi.it; Aquaro, Donato; Pupeschi, Simone; Moscardini, Marigrazia

    2014-10-15

    Highlights: • Thermal conductivity values of bed as function of a material of known conductivity. • Minimizing the error caused by radial heat transfer. • Experimental evaluation of thermal conductivity of alumina pebble at different temperatures. • Experimental test with/without compression load. - Abstract: The experimental determination of mechanical and thermal properties of ceramic pebble beds, such as the lithium orthosilicate or lithium metatitanate, is a key issue in the framework of fusion power technology, for the reason that they are possible candidates in the design of breeder blankets. The paper deals with an experimental method for the evaluation of the thermal conductivity of ceramic pebble beds versus the temperature and compressive strain, based on a steady state heat flux through a material (alumina) of known conductivity. The alumina thermal conductivity is determined by means of the hot wire method. To assess the experimental method, a thermo-mechanical characterization of alumina pebble beds (a material largely available), having different diameters, considering a wide range of temperatures and compression forces has been carried out. Moreover preliminary tests have been performed on lithium orthosilicate and lithium metatitanate pebble beds.

  1. A mechanical experimental setup to simulate vocal folds vibrations. Preliminary results

    CERN Document Server

    Ruty, Nicolas; Pelorson, Xavier; Lopez-Arteaga, Ines; Hirschberg, Avraham

    2005-01-01

    This paper contributes to the understanding of vocal folds oscillation during phonation. In order to test theoretical models of phonation, a new experimental set-up using a deformable vocal folds replica is presented. The replica is shown to be able to produce self sustained oscillations under controlled experimental conditions. Therefore different parameters, such as those related to elasticity, to acoustical coupling or to the subglottal pressure can be quantitatively studied. In this work we focused on the oscillation fundamental frequency and the upstream pressure in order to start (on-set threshold) either end (off-set threshold) oscillations in presence of a downstream acoustical resonator. As an example, it is shown how this data can be used in order to test the theoretical predictions of a simple one-mass model.

  2. Evaluating an experimental dentifrice containing chloramine-T: a preliminary study.

    Science.gov (United States)

    Tirapelli, Camila; Landi, Flávio; Ribas, José Paulo; Panzeri, Heitor; Lara, Elza Helena

    2010-01-01

    The aim of the present study was to evaluate the clinical efficacy of an experimental dentifrice (CH) containing an antimicrobial agent (1% chloramine-T). A clinical, fully randomised, double-blind comparative study was designed for 30 selected patients aged 15 to 50 years, with no periodontal disease, decay or other oral diseases, good general health and the presence of dental plaque and sulcus bleeding. Baseline Turesky modified plaque index (PI) and sulcus bleeding index (SBI) were scored for all patients. Volunteers randomly received the experimental dentifrice (CH) or a commercial-brand dentifrice containing triclosan (TR). Both dentifrices were provided in identical, number-labelled tubes, and the subjects were instructed to use the supplied dentifrice only for their usual oral hygiene, three times a day for a duration of 7 days. After 7-day use of dentifrices, the PI and SBI were assessed again. The data obtained were subjected to the Kruskal– Wallis test, followed by Dunn's post hoc test. After 7-day use of dentifrices, the PI scores diminished significantly for both evaluated dentifrices. The SBI values decreased significantly for both experimental and commercial-brand dentifrices. Both dentifrices reduced PI and SBI. By comparing the experimental and gold-standard dentifrice, it was found that there was no statistically significant difference between the PI and SBI scores after their use, suggesting that they exerted a similar effect on the oral health indexes.

  3. An Experimental Test of a Biodynamic Method of Weed Suppression: The Biodynamic Seed Peppers

    Directory of Open Access Journals (Sweden)

    Bruce Kenneth Kirchoff

    2016-04-01

    Full Text Available An experimental test of a biodynamic agriculture method of weed suppression was carried out in growth chambers to establish the feasibility of the method as a preliminary to field trials. Four generations of Brassica rapa plants were used in a randomized block design. Treated flats received ashed seeds prepared according to biodynamic indications. Seed weight and counts were measured at the end of each generation, and germination of the control and experimental seed was investigated at the end of generation four. The biodynamic seed peppers, created and applied as described here, had no effect on seed production or viability, and did not effectively inhibit reproduction of the targeted species over the course of four consecutive treatments.

  4. Numerical Simulation and Experimental Validation of Guided Ditching Tests

    OpenAIRE

    Siemann, Martin; Kohlgrüber, Dieter; Benítez Montañés, Luis; Iafrati, Alessandro

    2014-01-01

    The oblique water entry of structures with high horizontal speed is investigated in this work. First, the necessity of aircraft ditching analysis as well as the requirements for numerical tools to simulate aircraft ditching are described. The paper provides a brief explanation of an extensive experimental campaign of guided ditching tests carried out in the SMAES project. These tests are then simulated using a hybrid Smoothed Particle Hydrodynamics - Finite Elements modeling approach. Most re...

  5. Experimental tests for carbon nanomaterial synthesis using DC plasma jet

    Science.gov (United States)

    Lange, H.; Łabȩdź, O.; Tylska, I.; Huczko, A.; Bystrzejewski, M.

    2014-11-01

    In the frame of this work some experimental tests were performed in the plasma jet. Pure ethanol vapour alone or with the addition of fine iron powder were used to synthesize few-layer graphene or carbon-encapsulated iron nanoparticles, respectively.

  6. Preliminary report: in-plant safety/relief valve discharge load test, Monticello Plant

    Energy Technology Data Exchange (ETDEWEB)

    Chang, H.C. (comp.)

    1976-12-01

    This preliminary report covers the results of the test program of safety/relief valve (SRV) discharge load phenomena and the effects upon the Mark I primary containment torus structure of the Monticello Nuclear Power Plant. The objectives of the test were to provide a data base for verifying/improving analytical models and to measure the structural response of the torus to SRV discharges. Objectives, instrumentation, and test plan are described. Results of continuing data evaluation will be included in the final report scheduled for publication later in 1977.

  7. Preliminary environmental analysis of a geopressured-geothermal test well in Brazoria County, Texas

    Energy Technology Data Exchange (ETDEWEB)

    White, W.A.; McGraw, M.; Gustavson, T.C.; Meriwether, J.

    1977-11-16

    Preliminary environmental data, including current land use, substrate lithology, soils, natural hazards, water resources, biological assemblages, meteorological data, and regulatory considerations have been collected and analyzed for approximately 150 km/sup 2/ of land near Chocolate Bayou, Brazoria County, Texas, in which a geopressured-geothermal test well is to be drilled in the fall of 1977. The study was designed to establish an environmental data base and to determine, within spatial constraints set by subsurface reservoir conditions, environmentally suitable sites for the proposed well. Preliminary analyses of data revealed the eed for focusing on the following areas: potential for subsidence and fault activation, susceptibility of test well and support facilities to fresh- and salt-water flooding, possible effects of produced saline waters on biological assemblages and groundwaer resources, distribution of expansive soils, and effect of drilling and associated support activities on known archeological-cultural resources.

  8. Efficient preliminary floating offshore wind turbine design and testing methodologies and application to a concrete spar design.

    Science.gov (United States)

    Matha, Denis; Sandner, Frank; Molins, Climent; Campos, Alexis; Cheng, Po Wen

    2015-02-28

    The current key challenge in the floating offshore wind turbine industry and research is on designing economic floating systems that can compete with fixed-bottom offshore turbines in terms of levelized cost of energy. The preliminary platform design, as well as early experimental design assessments, are critical elements in the overall design process. In this contribution, a brief review of current floating offshore wind turbine platform pre-design and scaled testing methodologies is provided, with a focus on their ability to accommodate the coupled dynamic behaviour of floating offshore wind systems. The exemplary design and testing methodology for a monolithic concrete spar platform as performed within the European KIC AFOSP project is presented. Results from the experimental tests compared to numerical simulations are presented and analysed and show very good agreement for relevant basic dynamic platform properties. Extreme and fatigue loads and cost analysis of the AFOSP system confirm the viability of the presented design process. In summary, the exemplary application of the reduced design and testing methodology for AFOSP confirms that it represents a viable procedure during pre-design of floating offshore wind turbine platforms.

  9. Test for Nonlinear Input Output Relations in SISO Systems by Preliminary Data Analysis

    DEFF Research Database (Denmark)

    Knudsen, Torben

    2000-01-01

    This paper discusses and develops preliminary statistical tests for detecting nonlinearities in the deterministic part of SISO systems with noise. The most referenced method is unreliable for common noise processes as e.g.\\ colored. Therefore two new methods based on superposition and sinus input...... are developed. They are much more robust, especially the sinus method which is reliable also for colored, heavy tailed or skew distributed noise....

  10. Children’s Foreign Language Anxiety Scale: Preliminary Tests of Reliability and Validity

    OpenAIRE

    Aydın, Selami; Harputlu, Leyla; Güzel, Serhat; Uştuk, Özgehan; Savran Çelik, Şeyda; Genç, Deniz

    2016-01-01

    Foreign language anxiety (FLA), which constitutes a serious problem in the foreign language learning process, has been mainly seen as a research issue regarding adult language learners, while it has been overlooked in children. This is because there is a lack of appropriate tools to measure FLA among children, whereas there are many studies on the scales that aim to measure anxiety levels among adult learners. Thus, the current study aims to conduct the preliminary tests of reliability and va...

  11. Effect of Reinforcement on Early-Age Concrete Temperature Stress: Preliminary Experimental Investigation and Analytical Simulation

    Directory of Open Access Journals (Sweden)

    Jianda Xin

    2015-01-01

    Full Text Available For concrete under short-term loading, effect of reinforcement on concrete crack resistance capability is usually negligible; however, recent research results show that extension of this viewpoint to concrete under long-term loading (temperature variation may be unsuitable. In order to investigate this phenomenon, this paper presents the experimental and analytical results of early-age reinforced concrete temperature stress development under uniaxial restraint. The experiments were carried out on a temperature stress testing machine (TSTM. Experimental results show that the coupling of reinforcement and concrete creep behavior influenced the concrete temperature stress development, and nearly 16% of concrete stress was reduced in the current research. Moreover, the cracking time of reinforced concrete was also delayed. Finally, based on the principle of superposition, analytical simulations of effect of reinforcement on concrete temperature stress have been performed.

  12. The analysis of experimental data obtained from automotives tests

    Science.gov (United States)

    Stoica, R. M.; Radulescu, V. J.; Neagu, D.; Trocan, C.; Copae, I.

    2016-08-01

    The paper highlights the three important and inseparably aspects of the systemic approach of automotives dynamics: taking into account the human-vehicle-field interaction, dealing movement with algorithms specific to system theory and analysis of experimental data with algorithms specific to signals theory.Within the paper, the systemic approach regarding vehicles dynamics is based on experimental data obtained from tests, whereby it is analyzed the movement and there are obtained movement mathematical models through algorithms of systems identification.Likewise, there are shown main analysis methods for experimental data, which uses probability theory, information theory, correlation analysis and variance analysis;in addition, there are highlighted possibilities given by time analysis, frequency analysis and data time-frequency analysis. Identification algorithms and highlighted analysis procedures assure the study of automotives dynamics and fuel saving,by directly using experimental data, or by using mathematical models and applying concepts and algorithms specific to systems theory. Experimental data were obtained by testing automotives with electronic control devices and by using acquisition and storage equipmentsfor data given by the on-board computer and taken from embedded sensors.

  13. Beam Dynamics for the Preliminary Phase of the New CLIC Test Facility (CTF3)

    CERN Document Server

    Corsini, R; Rinolfi, Louis; Risselada, Thys; Royer, P; Tecker, F A

    2001-01-01

    In the framework of the CLIC (Compact Linear Collider) RF power source studies, the scheme of electron pulse compression and bunch frequency mulitiplication, using injection by RF deflectors into an isochronous ring, will be tested, at low charge, during the preliminary phase of the new CLIC Test Facility (CTF3) at CERN. In this paper, we describe the beam dynamics studies made in order to assess the feasibility of the bunch combination experiment, as well as the related beam measurements performed on the LEP Pre-Injector complex (LPI) before its transformation into CTF3

  14. Blade system design studies volume II : preliminary blade designs and recommended test matrix.

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Dayton A. (Global Energy Concepts, LLC, Kirkland, WA)

    2004-06-01

    As part of the U.S. Department of Energy's Wind Partnerships for Advanced Component Technologies (WindPACT) program, Global Energy Concepts, LLC is performing a Blade System Design Study (BSDS) concerning innovations in materials, processes and structural configurations for application to wind turbine blades in the multi-megawatt range. The BSDS Volume I project report addresses issues and constraints identified to scaling conventional blade designs to the megawatt size range, and evaluated candidate materials, manufacturing and design innovations for overcoming and improving large blade economics. The current report (Volume II), presents additional discussion of materials and manufacturing issues for large blades, including a summary of current trends in commercial blade manufacturing. Specifications are then developed to guide the preliminary design of MW-scale blades. Using preliminary design calculations for a 3.0 MW blade, parametric analyses are performed to quantify the potential benefits in stiffness and decreased gravity loading by replacement of a baseline fiberglass spar with carbon-fiberglass hybrid material. Complete preliminary designs are then presented for 3.0 MW and 5.0 MW blades that incorporate fiberglass-to-carbon transitions at mid-span. Based on analysis of these designs, technical issues are identified and discussed. Finally, recommendations are made for composites testing under Part I1 of the BSDS, and the initial planned test matrix for that program is presented.

  15. Characteristics, finite element analysis, test description, and preliminary test results of the STM4-120 kinematic Stirling engine

    Science.gov (United States)

    Linker, K. L.; Rawlinson, K. S.; Smith, G.

    1991-10-01

    The Department of Energy's Solar Thermal Program has, as one of its program elements, the development and evaluation of conversion device technologies applicable to dish-electric systems. The primary research and development combines a conversion device (heat engine), solar receiver, and generator mounted at the focus of a parabolic dish concentrator. The Stirling-cycle heat engine was identified as the conversion device for dish-electric with the most potential for meeting the program's goals for efficiency, reliability, and installed cost. To advance the technology toward commercialization, Sandia National Laboratories has acquired a Stirling Thermal Motors, Inc. kinematic Stirling engine, STM4-120, for evaluation. The engine is being bench-tested at Sandia's Engine Test Facility and will be combined later with a solar receiver for on-sun evaluation. This report presents the engine characteristics, finite element analyses of critical engine components, test system layout, instrumentation, and preliminary performance results from the bench test.

  16. Immune Biomarker Response Depends on Choice of Experimental Pain Stimulus in Healthy Adults: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Yenisel Cruz-Almeida

    2012-01-01

    Full Text Available Few studies in healthy subjects have examined the neuroimmune responses associated with specific experimental pain stimuli, while none has measured multiple biomarkers simultaneously. The aim of the present study was to compare the neuro-immune responses following two common experimental pain stimuli: cold pressor test (CPT and focal heat pain (FHP. Eight adults participated in two counterbalanced experimental sessions of FHP or CPT with continuous pain ratings and blood sampling before and 30 minutes after the sessions. Despite similar pain intensity ratings (FHP = 42.2±15.3; CPT = 44.5±34.1; P=0.871, CPT and FHP induced different neuro-immune biomarker responses. CPT was accompanied by significant increases in cortisol (P=0.046 and anti-inflammatory cytokine IL-10 (P=0.043 with significant decreases in several pro-inflammatory mediators (IL-1β (P=0.028, IL-12 (P=0.012, TNF-α (P=0.039, and MCP-1 (P=0.038. There were nonsignificant biomarker changes during the FHP session. There were close to significant differences between the sessions for IL-1β (P=0.081, IFN-γ (P=0.072, and IL-12 (P=0.053 with biomarkers decreasing after CPT and increasing after FHP. There were stronger associations between catastrophizing and most biomarkers after CPT compared to FHP. Our results suggest that CPT is a stressful and painful stimulus, while FHP is mostly a painful stimulus. Thus, each experimental pain stimulus can activate different neuro-immune cascades, which are likely relevant for the interpretation of studies in chronic pain conditions.

  17. Preliminary studies on the antinociceptive activity of Vaccinium ashei berry in experimental animal models.

    Science.gov (United States)

    Ramirez, Maria Rosana; Guterres, Leandra; Dickel, Odila E; de Castro, Micheli R; Henriques, Amelia T; de Souza, Márcia M; Barros, Daniela Martí

    2010-04-01

    The aim of this study was to carry out pharmacological screening in order to evaluate the potential effects of lyophilized fruits of different cultivars of Vaccinium ashei Reade (Family Ericaceae) berries, commonly known as rabbiteye blueberries, on nociception. This was achieved using the formalin, hot plate, tail-flick, and writhing tests in mice. During this experiment the mice consumed approximately 3.2-6.4 mg/kg/day (p.o.) of the anthocyanins. The extract was administered for 21 days or 60 minutes before test. Morphine and diclofenac (10 mg/kg, p.o.) as the standard drug (positive control) and water (via oral gavage) as the negative control were administered before all tests. The blueberry extract produced a significant decrease in constrictions induced by acetic acid and caused graded inhibition of the second phase of formalin-induced pain. Moreover, in both the hot plate and tail-flick tests, it significantly increased the threshold. These data suggest that the extract from V. ashei produced antinociceptive effects, as demonstrated in the experimental models of nociception in mice. Additional experiments are necessary in order to clarify the true target for the antinociceptive effects of rabbiteye blueberry extract.

  18. How can we test the neutrino mass seesaw mechanism experimentally?

    Science.gov (United States)

    Buckley, Matthew R; Murayama, Hitoshi

    2006-12-01

    The seesaw mechanism for the small neutrino mass has been a popular paradigm, yet it has been believed that there is no way to test it experimentally. We present a conceivable outcome from future experiments that would convince us of the seesaw mechanism. It would involve data from the CERN Large Hadron Collider, International Linear Collider, cosmology, underground, and low-energy flavor experiments to establish the case.

  19. Velocity Measurements in Nasal Cavities by Means of Stereoscopic Piv - Preliminary Tests

    Science.gov (United States)

    Cozzi, Fabio; Felisati, Giovanni; Quadrio, Maurizio

    2017-08-01

    The prediction of detailed flow patterns in human nasal cavities using computational fluid dynamics (CFD) can provide essential information on the potential relationship between patient-specific geometrical characteristics of the nasal anatomy and health problems, and ultimately led to improved surgery. The complex flow structure and the intricate geometry of the nasal cavities make achieving such goals a challenge for CFD specialists. The need for experimental data to validate and improve the numerical simulations is particularly crucial. To this aim an experimental set-up based on Stereo PIV and a silicon phantom of nasal cavities have been designed and realized at Politecnico di Milano. This work describes the main features and challenges of the set-up along with some preliminary results.

  20. A new extra-abdominal channel alternative to the mitrofanoff principle: experimental and preliminary clinical experience

    Directory of Open Access Journals (Sweden)

    Antonio Macedo Jr.

    2009-04-01

    Full Text Available INTRODUCTION: The appendix is the gold-standard channel for the Mitrofanoff principle in pediatric urology, but the search for alternatives is justified considering it may not be available or preferably used for colonic stomas (Malone antegrade continence enema. The aim of this study is to report on technical feasibility of a new approach for creating catheterizable channels in a rabbit model and to present our preliminary clinical experience. MATERIAL AND METHODS: We configured a tube from two rectangular skin flaps 1x4 cm opposite each other in the middle line of the lower inferior abdomen. The channel was anastomosed to the bladder dome with embedding sutures to create a valvular mechanism. The experimental study consisted of 12 rabbits, divided in 4 groups according to the sacrifice schedule at 2, 4, 8 and 12 weeks. At 30th postoperative day, an urodynamic evaluation was performed to record continence of the stoma. A histological analysis of the specimens stained with hematoxylin-eosin, Masson trichrome and Picrosirius red was also done in group 2 (sacrifice at 4 weeks postoperatively. We used this method in 3 patients with congenital non-neurogenic bladder disease presenting with massive residual volumes without compliance deficits. RESULT: The technique proved feasible in all animals, 9 of 12 could be easily catheterized and underwent urodynamic study. No stoma leakage was observed in 7 animals at high bladder pressures (> 50 cm H20 and only 2 animals had some leakage at 40 cm H20. Urodynamics performed through the stoma showed urethral leakage at 20 cm H20, therefore demonstrating the efficacy of the valvular mechanism. Histological analysis confirmed good integration between the tube and the bladder. Mean follow-up of the clinical series (3 patients was 7.2 months. Two patients remained continent up to 4 hours, whereas 1 patient had some leakage after 2 hours. CONCLUSION: We were able to confirm feasibility of a new extra

  1. Target Soil Impact Verification: Experimental Testing and Kayenta Constitutive Modeling.

    Energy Technology Data Exchange (ETDEWEB)

    Broome, Scott Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Flint, Gregory Mark [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Dewers, Thomas [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Newell, Pania [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    This report details experimental testing and constitutive modeling of sandy soil deformation under quasi - static conditions. This is driven by the need to understand constitutive response of soil to target/component behavior upon impact . An experimental and constitutive modeling program was followed to determine elastic - plastic properties and a compressional failure envelope of dry soil . One hydrostatic, one unconfined compressive stress (UCS), nine axisymmetric compression (ACS) , and one uniaxial strain (US) test were conducted at room temperature . Elastic moduli, assuming isotropy, are determined from unload/reload loops and final unloading for all tests pre - failure and increase monotonically with mean stress. Very little modulus degradation was discernable from elastic results even when exposed to mean stresses above 200 MPa . The failure envelope and initial yield surface were determined from peak stresses and observed onset of plastic yielding from all test results. Soil elasto - plastic behavior is described using the Brannon et al. (2009) Kayenta constitutive model. As a validation exercise, the ACS - parameterized Kayenta model is used to predict response of the soil material under uniaxial strain loading. The resulting parameterized and validated Kayenta model is of high quality and suitable for modeling sandy soil deformation under a range of conditions, including that for impact prediction.

  2. On the Force Drop Off Phenomenon in Shaker Testing in Experimental Modal Analysis

    Directory of Open Access Journals (Sweden)

    Paulo Sergio Varoto

    2002-01-01

    Full Text Available The Electrodynamic Vibration Exciter (shakers has been one of the most employed excitation sources in modal tests. The shaker is an electromechanical device that provides a mechanical motion due to the input signal sent to its coil. Despite being widely used, it is well known that the shaker interacts with the structure under test. In particular, when the structure passes through a given resonance, the force delivered by the shaker abruptly decreases, causing the so called drop off phenomenon. This paper aims to study this force drop off phenomenon in the single shaker modal testing. Analytical models are developed to help in understanding the physical principles involved in the interaction between the shaker and the structure under test. Experimental analyses are performed using different shakers as well as excitation signals, in order to evaluate the effects of the input signal, as well as the power amplifier operational modes, on the structure dynamics. Preliminary tests revealed that significant distortions might occur during vibration tests using shakers and these distortions significantly affect the determination of the structure response.

  3. Preliminary Test of Friction disk type turbine for S-CO{sub 2} cycle application

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Seungjoon; Kim, Hyeon Tae; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    Due to the relatively mild sodium-CO{sub 2} interaction, the S-CO{sub 2} Brayton cycle can reduce the accident consequence compared to the steam Rankine cycle. Also the S-CO{sub 2} power conversion cycle can achieve high efficiency for SFR core thermal condition. Moreover, the S-CO{sub 2} power cycle can reduce the total cycle footprint due to high density of the working fluid. However, the high pressure operating condition and low viscosity of the fluid cause difficulties in designing appropriate seals and multi-stage turbo machineries. To solve the problem for designing turbo machineries in a creative way, KAIST research team tested a friction disk type turbine concept for the S-CO{sub 2} cycle application. In this paper, the investigation of the Tesla turbine and preliminary test results with compressed air are covered. The KAIST research team investigated a friction disk type turbine, named as Tesla turbine, for the S-CO{sub 2} power cycle applications. Due to the robust design of the fiction disk type, the Tesla turbine technology can be utilized not only for S-CO{sub 2} turbo machinery but also for the multi-phase or sludge flow turbo machinery. The preliminary test of lab-scale Tesla turbine with compressed air was conducted. The high pressure vessel was manufactured for the S-CO{sub 2} operating condition. The test will be concentrated on the turbine efficiency measurement under various conditions and development of the design methodology.

  4. A Preliminary Analysis of Reactor Performance Test (LOEP) for a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeonil; Park, Su-Ki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The final phase of commissioning is reactor performance test, which is to prove the integrated performance and safety of the research reactor at full power with fuel loaded such as neutron power calibration, Control Absorber Rod/Second Shutdown Rod drop time, InC function test, Criticality, Rod worth, Core heat removal with natural mechanism, and so forth. The last test will be safety-related one to assure the result of the safety analysis of the research reactor is marginal enough to be sure about the nuclear safety by showing the reactor satisfies the acceptance criteria of the safety functions such as for reactivity control, maintenance of auxiliaries, reactor pool water inventory control, core heat removal, and confinement isolation. After all, the fuel integrity will be ensured by verifying there is no meaningful change in the radiation levels. To confirm the performance of safety equipment, loss of normal electric power (LOEP), possibly categorized as Anticipated Operational Occurrence (AOO), is selected as a key experiment to figure out how safe the research reactor is before turning over the research reactor to the owner. This paper presents a preliminary analysis of the reactor performance test (LOEP) for a research reactor. The results showed how different the transient between conservative estimate and best estimate will look. Preliminary analyses have shown all probable thermal-hydraulic transient behavior of importance as to opening of flap valve, minimum critical heat flux ratio, the change of flow direction, and important values of thermal-hydraulic parameters.

  5. Ossiculoplasty in Missing Malleus and Stapes Patients : Experimental and Preliminary Clinical Results With a New Malleus Replacement Prosthesis With the Otology-Neurotology Database

    NARCIS (Netherlands)

    Vincent, Robert; Bittermann, Arnold J. N.; Wenzel, Gentiana; Oates, John; Sperling, Neil; Lenarz, Thomas; Grolman, Wilko

    2013-01-01

    Objective: To present the preliminary results of new malleus replacement prosthesis combined with a total ossicular prosthesis in middle ear reconstruction in patients missing the malleus and stapes. Study Design: Prospective experimental and nonrandomized clinical study. Setting: Tertiary referral

  6. Experimental study on subaperture testing with iterative triangulation algorithm.

    Science.gov (United States)

    Yan, Lisong; Wang, Xiaokun; Zheng, Ligong; Zeng, Xuefeng; Hu, Haixiang; Zhang, Xuejun

    2013-09-23

    Applying the iterative triangulation stitching algorithm, we provide an experimental demonstration by testing a Φ120 mm flat mirror, a Φ1450 mm off-axis parabolic mirror and a convex hyperboloid mirror. By comparing the stitching results with the self-examine subaperture, it shows that the reconstruction results are in consistent with that of the subaperture testing. As all the experiments are conducted with a 5-dof adjustment platform with big adjustment errors, it proves that using the above mentioned algorithm, the subaperture stitching can be easily performed without a precise positioning system. In addition, with the algorithm, we accomplish the coordinate unification between the testing and processing that makes it possible to guide the processing by the stitching result.

  7. CSI Flight Computer System and experimental test results

    Science.gov (United States)

    Sparks, Dean W., Jr.; Peri, F., Jr.; Schuler, P.

    1993-01-01

    This paper describes the CSI Computer System (CCS) and the experimental tests performed to validate its functionality. This system is comprised of two major components: the space flight qualified Excitation and Damping Subsystem (EDS) which performs controls calculations; and the Remote Interface Unit (RIU) which is used for data acquisition, transmission, and filtering. The flight-like RIU is the interface between the EDS and the sensors and actuators positioned on the particular structure under control. The EDS and RIU communicate over the MIL-STD-1553B, a space flight qualified bus. To test the CCS under realistic conditions, it was connected to the Phase-0 CSI Evolutionary Model (CEM) at NASA Langley Research Center. The following schematic shows how the CCS is connected to the CEM. Various tests were performed which validated the ability of the system to perform control/structures experiments.

  8. MOTIVATION AND PERFORMANCE IN PHYSICAL EDUCATION: AN EXPERIMENTAL TEST

    Directory of Open Access Journals (Sweden)

    Juan A. Moreno

    2010-03-01

    Full Text Available The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls, aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance

  9. Pb-16Li/water interaction: Experimental results and preliminary modelling activities

    Energy Technology Data Exchange (ETDEWEB)

    Ciampichetti, Andrea, E-mail: andrea.ciampichetti@enea.it [ENEA C.R. Brasimone, 40032 Camugno (Italy); Ricapito, Italo [Fusion for Energy, 08019 Barcelona (Spain); Forgione, Nicola; Pesetti, Alessio [Università di Pisa, DIMNP, Largo Lucio Lazzarino 2, 56122 Pisa (Italy)

    2013-10-15

    Highlights: • We studied the interaction between pressurised water and liquid Pb16Li. • The free volume is more impacting than the water enthalpy in determining the pressure evolution of the system. • If a large quantity of water is injected in Pb16Li the temperature increase is very high. • The pressure trends computed by the SIMMER code show a quite good agreement with the experimental data. • From the results some recommendations about the WCLL blanket design can be derived. -- Abstract: The Water Cooled Lithium Lead (WCLL) blanket is based on the eutectic liquid alloy Pb16Li as breeder material and neutron multiplier, and pressurised water as coolant. The liquid breeder flows at few mm/s in the blanket module while the pressurised water is circulated inside double-wall tubes. In spite of the adoption of double-wall tubes for the coolant, the probability of a water large leak because of a tube rupture accident cannot be considered negligible. As a consequence, the Pb16Li/water interaction due to a large break in one or more cooling tubes still remains one of the biggest concerns for this blanket concept. This paper reports the results of three experimental tests on Pb16Li/water interaction carried out at ENEA-Brasimone operating the LIFUS 5 facility. Water was injected into the reaction tank, containing Pb16Li at 330 °C, at a pressure of 155 bar with different values of sub-cooling and with different free volumes in the reaction system. In addition, post test analyses with SIMMER III code are presented in order to compare the pressure evolution measured during the experiments with that calculated by the code.

  10. Furniture wood wastes: experimental property characterisation and burning tests.

    Science.gov (United States)

    Tatàno, Fabio; Barbadoro, Luca; Mangani, Giovanna; Pretelli, Silvia; Tombari, Lucia; Mangani, Filippo

    2009-10-01

    Referring to the industrial wood waste category (as dominant in the provincial district of Pesaro-Urbino, Marche Region, Italy), this paper deals with the experimental characterisation and the carrying out of non-controlled burning tests (at lab- and pilot-scale) for selected "raw" and primarily "engineered" ("composite") wood wastes. The property characterisation has primarily revealed the following aspects: potential influence on moisture content of local weather conditions at outdoor wood waste storage sites; generally, higher ash contents in "engineered" wood wastes as compared with "raw" wood wastes; and relatively high energy content values of "engineered" wood wastes (ranging on the whole from 3675 to 5105 kcal kg(-1) for HHV, and from 3304 to 4634 kcal kg(-1) for LHV). The smoke qualitative analysis of non-controlled lab-scale burning tests has primarily revealed: the presence of specific organic compounds indicative of incomplete wood combustion; the presence exclusively in "engineered" wood burning tests of pyrroles and amines, as well as the additional presence (as compared with "raw" wood burning) of further phenolic and containing nitrogen compounds; and the potential environmental impact of incomplete industrial wood burning on the photochemical smog phenomenon. Finally, non-controlled pilot-scale burning tests have primarily given the following findings: emission presence of carbon monoxide indicative of incomplete wood combustion; higher nitrogen oxide emission values detected in "engineered" wood burning tests as compared with "raw" wood burning test; and considerable generation of the respirable PM(1) fraction during incomplete industrial wood burning.

  11. Experimental test of Bohr's complementarity principle with single neutral atoms

    Science.gov (United States)

    Wang, Zhihui; Tian, Yali; Yang, Chen; Zhang, Pengfei; Li, Gang; Zhang, Tiancai

    2016-12-01

    An experimental test of the quantum complementarity principle based on single neutral atoms trapped in a blue detuned bottle trap was here performed. A Ramsey interferometer was used to assess the wavelike behavior or particlelike behavior with second π /2 rotation on or off. The wavelike behavior or particlelike behavior is characterized by the visibility V of the interference or the predictability P of which-path information, respectively. The measured results fulfill the complementarity relation P2+V2≤1 . Imbalance losses were deliberately introduced to the system and we find the complementarity relation is then formally "violated." All the experimental results can be completely explained theoretically by quantum mechanics without considering the interference between wave and particle behaviors. This observation complements existing information concerning Bohr's complementarity principle based on wave-particle duality of a massive quantum system.

  12. The LOBI Integral System Test Facility Experimental Programme

    Directory of Open Access Journals (Sweden)

    Carmelo Addabbo

    2012-01-01

    Full Text Available The LOBI project has been carried out in the framework of the European Commission Reactor Safety Research Programme in close collaboration with institutional and/or industrial research organizations of EC member countries. The primary objective of the research programme was the generation of an experimental data base for the assessment of the predictive capabilities of thermal-hydraulic system codes used in pressurised water reactor safety analysis. Within this context, experiments have been conducted in the LOBI integral system test facility designed, constructed, and operated (1979–1991 at the Ispra Site of the Joint Research Centre. This paper provides a historical perspective and summarizes major achievements of the research programme which has represented an effective approach to international collaboration in the field of reactor safety research and development. Emphasis is also placed on knowledge management aspects of the acquired experimental data base and on related online open access/retrieval user functionalities.

  13. Experimental device-independent tests of classical and quantum entropy

    Science.gov (United States)

    Zhu, Feng; Zhang, Wei; Chen, Sijing; You, Lixing; Wang, Zhen; Huang, Yidong

    2016-12-01

    In quantum information processing, it is important to witness the entropy of the message in the device-independent way which was proposed recently [R. Chaves, J. B. Brask, and N. Brunner, Phys. Rev. Lett. 115, 110501 (2015), 10.1103/PhysRevLett.115.110501]. In this paper, we theoretically obtain the minimal quantum entropy for three widely used linear dimension witnesses, which is considered "a difficult question." Then we experimentally test the classical and quantum entropy in a device-independent manner. The experimental results agree well with the theoretical analysis, demonstrating that entropy is needed in quantum systems that is lower than the entropy needed in classical systems with the given value of the dimension witness.

  14. Experimental Design for the INL Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G.; Piepel, Gregory F.; Matzke, Brett D.; Filliben, James J.; Jones, Barbara

    2007-12-13

    This document describes the test events and numbers of samples comprising the experimental design that was developed for the contamination, decontamination, and sampling of a building at the Idaho National Laboratory (INL). This study is referred to as the INL Sample Collection Operational Test. Specific objectives were developed to guide the construction of the experimental design. The main objective is to assess the relative abilities of judgmental and probabilistic sampling strategies to detect contamination in individual rooms or on a whole floor of the INL building. A second objective is to assess the use of probabilistic and Bayesian (judgmental + probabilistic) sampling strategies to make clearance statements of the form “X% confidence that at least Y% of a room (or floor of the building) is not contaminated. The experimental design described in this report includes five test events. The test events (i) vary the floor of the building on which the contaminant will be released, (ii) provide for varying or adjusting the concentration of contaminant released to obtain the ideal concentration gradient across a floor of the building, and (iii) investigate overt as well as covert release of contaminants. The ideal contaminant gradient would have high concentrations of contaminant in rooms near the release point, with concentrations decreasing to zero in rooms at the opposite end of the building floor. For each of the five test events, the specified floor of the INL building will be contaminated with BG, a stand-in for Bacillus anthracis. The BG contaminant will be disseminated from a point-release device located in the room specified in the experimental design for each test event. Then judgmental and probabilistic samples will be collected according to the pre-specified sampling plan. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples will be selected in sufficient numbers to provide desired confidence

  15. Preliminary test of the prototype modular cryostat for a 10 MW offshore superconducting wind turbine

    Science.gov (United States)

    Sun, Jiuce; Ramalingam, R.; Sanz, Santiago; Neumann, Holger

    2017-02-01

    The SUPerconducting Reliable lightweight And more POWERful offshore wind turbine (SUPRAPOWER), an EU FP7 funded research project, are under development for an innovative superconducting 10 MW class offshore wind turbine. Due to the requirements of handling, maintenance, reliability of long term and offshore operation, the cryostats are divided in two major parts: the modular cryostat able to accommodate a single coil and a thermal collector that links all the modules. The prototype modular cryostat was designed, manufactured and assembled in Karlsruhe Institute of Technology (KIT). The paper reports preliminary test results of proto-type modular cryostat with a two-stage Gifford-McMahon (GM) cryocooler.

  16. Analyses of the OSU-MASLWR Experimental Test Facility

    Directory of Open Access Journals (Sweden)

    F. Mascari

    2012-01-01

    Full Text Available Today, considering the sustainability of the nuclear technology in the energy mix policy of developing and developed countries, the international community starts the development of new advanced reactor designs. In this framework, Oregon State University (OSU has constructed, a system level test facility to examine natural circulation phenomena of importance to multi-application small light water reactor (MASLWR design, a small modular pressurized water reactor (PWR, relying on natural circulation during both steady-state and transient operation. The target of this paper is to give a review of the main characteristics of the experimental facility, to analyse the main phenomena characterizing the tests already performed, the potential transients that could be investigated in the facility, and to describe the current IAEA International Collaborative Standard Problem that is being hosted at OSU and the experimental data will be collected at the OSU-MASLWR test facility. A summary of the best estimate thermal hydraulic system code analyses, already performed, to analyze the codes capability in predicting the phenomena typical of the MASLWR prototype, thermal hydraulically characterized in the OSU-MASLWR facility, is presented as well.

  17. Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.

    2015-01-01

    A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.

  18. Turkish children's Bender-Gestalt Test performance: a pilot study and preliminary norms.

    Science.gov (United States)

    Ozer, Serap

    2007-12-01

    The present study was undertaken to provide preliminary data for norms on the Bender-Gestalt Test for 253 children ages 5 yr., 5 mo. to 11 yr., 10 mo. in Turkey. The Koppitz Developmental Scoring System gave mean error scores of 4.2 (SD = 3.3) for girls and 3.6 (SD = 3.0) for boys. The mean error scores obtained by all age groups are presented and compared with other cross-cultural data. These scores decreased across age groups, supporting Bender's maturational hypothesis of the test. The present sample performed at a higher developmental level than the Koppitz normative sample for the 5- and 6-year age groups, while means for other age groups were similar to the original U.S. norms. That this pattern is supported in other cross-cultural studies is discussed as well as the importance of developing local norms for visual spatial tests.

  19. Preliminary optical design of an Active Optics test bench for space applications.

    Science.gov (United States)

    Calcines, A.; Bitenc, U.; Rolt, S.; Reeves, S.; Doelman, N.; Human, J.; Morris, T.; Myers, R.; Talbot, G.

    2017-03-01

    This communication presents a preliminary optical design for a test bench conceived within the European Space Agency's TRP project (Active Optics Correction Chain (AOCC) for large monolithic mirrors) with the goal of designing and developing an Active Optics system able to correct in space on telescopes apertures larger than 3 meters. The test bench design uses two deformable mirrors of 37.5 mm and 116 mm, the smallest mirror to generate aberrations and the largest one to correct them. The system is configured as a multi-functional test bench capable of verifying the performance of a Shack-Hartmann wavefront sensor as well as of a Phase Diversity based wavefront sensor. A third optical path leads to a high-order Shack-Hartmann wavefront sensor to monitor the entire system performance.

  20. The NASA Juncture Flow Experiment: Goals, Progress, and Preliminary Testing (Invited)

    Science.gov (United States)

    Rumsey, Christopher L.; Neuhart, Danny H.; Kegerise, Michael A.

    2016-01-01

    NASA has been working toward designing and conducting a juncture flow experiment on a wing-body aircraft configuration. The experiment is planned to provide validation-quality data for CFD that focuses on the onset and progression of a separation bubble near the wing-body juncture trailing edge region. This paper describes the goals and purpose of the experiment. Although currently considered unreliable, preliminary CFD analyses of several different configurations are shown. These configurations have been subsequently tested in a series of "risk-reduction" wind tunnel tests, in order to help down-select to a final configuration that will attain the desired flow behavior. The risk-reduction testing at the higher Reynolds number has not yet been completed (at the time of this writing), but some results from one of the low-Reynolds-number experiments are shown.

  1. Experimental Test of Nonclassicality for a Single Particle

    Science.gov (United States)

    2008-08-01

    R. Y. Chiao, “Correlated two-photon interference in a dual-beam Michelson interferometer ,” Phys. Rev. A 41, 2910-2913 (1990). 9. T. E. Kiess, Y. H...M. D. Eisaman, E. A. Goldschmidt, J. Chen, J. Fan, and A. Migdall, “Experimental test of nonlocal realism using a fiber -based source of polarization...experiment, photons in the heralding arm are routed by a single-mode fiber (SMF) to a Si-single-photon Avalanche Diode (SPAD) operating in Geiger mode, while

  2. Integral Test Facility PKL: Experimental PWR Accident Investigation

    OpenAIRE

    2012-01-01

    Investigations of the thermal-hydraulic behavior of pressurized water reactors under accident conditions have been carried out in the PKL test facility at AREVA NP in Erlangen, Germany for many years. The PKL facility models the entire primary side and significant parts of the secondary side of a pressurized water reactor (PWR) at a height scale of 1 : 1. Volumes, power ratings and mass flows are scaled with a ratio of 1 : 145. The experimental facility consists of 4 primary loops with circul...

  3. Experimental Test of Quantum Contextuality in Neutron Interferometry

    Science.gov (United States)

    Bartosik, H.; Klepp, J.; Schmitzer, C.; Sponar, S.; Cabello, A.; Rauch, H.; Hasegawa, Y.

    2009-07-01

    We performed an experimental test of the Kochen-Specker theorem based on an inequality derived from the Peres-Mermin proof, using spin-path (momentum) entanglement in a single neutron system. Following the strategy proposed by Cabello et al. [Phys. Rev. Lett. 100, 130404 (2008)PRLTAO0031-900710.1103/PhysRevLett.100.130404], a Bell-like state was generated, and three expectation values were determined. The observed violation 2.291±0.008≰1 clearly shows that quantum mechanical predictions cannot be reproduced by noncontextual hidden-variable theories.

  4. A preliminary analysis of the data from an in vitro inflation-extension test can validate the assumption of arterial tissue elasticity.

    Science.gov (United States)

    Rachev, Alexander; Shazly, Tarek

    2013-08-01

    The objective of this study is to propose a method for preliminary processing of the experimental data from an inflation-extension test on tubular arterial specimens. The method is based on the condition for existence of a strain energy function (SEF) and can be used to verify whether the data from a certain experiment validate the assumption that the tissue can be considered as an elastic solid. As an illustrative example of the proposed method, experimental data for a porcine renal artery are used and the sources of the error in satisfying the condition of elasticity are analyzed. The results lead to the conclusion that the experimental data for a renal artery validate that the artery exhibits an elastic mechanical response and a constitutive formulation based on the existence of the SEF is justified. A modification of the proposed method for the case of an in-plane biaxial stretching test of mechanically isotropic and orthotropic tissues is considered.

  5. [Reduction of animal experiments in experimental drug testing].

    Science.gov (United States)

    Behrensdorf-Nicol, H; Krämer, B

    2014-10-01

    In order to ensure the quality of biomedical products, an experimental test for every single manufactured batch is required for many products. Especially in vaccine testing, animal experiments are traditionally used for this purpose. For example, efficacy is often determined via challenge experiments in laboratory animals. Safety tests of vaccine batches are also mostly performed using laboratory animals. However, many animal experiments have clear inherent disadvantages (low accuracy, questionable transferability to humans, unclear significance). Furthermore, for ethical reasons and animal welfare aspects animal experiments are also seen very critical by the public. Therefore, there is a strong trend towards replacing animal experiments with methods in which no animals are used ("replacement"). If a replacement is not possible, the required animal experiments should be improved in order to minimize the number of animals necessary ("reduction") and to reduce pain and suffering caused by the experiment to a minimum ("refinement"). This "3R concept" is meanwhile firmly established in legislature. In recent years many mandatory animal experiments have been replaced by alternative in vitro methods or improved according to the 3R principles; numerous alternative methods are currently under development. Nevertheless, the process from the development of a new method to its legal implementation takes a long time. Therefore, supplementary regulatory measures to facilitate validation and acceptance of new alternative methods could contribute to a faster and more consequent implementation of the 3R concept in the testing of biomedical products.

  6. The Cleveland Sorting Test: a preliminary study of an alternate form of the Wisconsin Card-Sorting Test.

    Science.gov (United States)

    Poreh, Amir; Pastel, Dan; Miller, Ashley; Levin, Jennifer

    2012-01-01

    During the past two decades, studies have repeatedly shown that the Wisconsin Card-Sorting Test (WCST) is not as sensitive to prefrontal-lobe functioning as was originally suspected. Specifically, both clinical and brain-imaging studies have shown that several distinct neural circuits contribute to one's ability to successfully complete different aspects of the test. Another limitation of the WCST is its length, which makes it difficult and frustrating for certain clinical populations. To address the above limitations, researchers have proposed the development of new indexes and the integration of an adaptive testing approach that will allow for the premature termination of the test. Unfortunately, given the proprietary nature of the WCST, none of the above recommendations have been adopted. The present preliminary study examined an alternate form of the 64-Item WCST (WCST-64), the Cleveland Sorting Test (CST-64). The normative data of the two measures as well as the total number of errors, perseverative responses, perseverative errors, and categories completed were compared using a repeated-measures design. Overall, the study supports psychometric approximation of the CST-64 and the WCST-64. Suggestions for future studies and modifications of the CST-64, including the use of recently proposed indexes and adaptive administration approaches, are provided.

  7. Preliminary Experimental Study on Pressure Loss Coefficients of Exhaust Manifold Junction

    Directory of Open Access Journals (Sweden)

    Xiao-lu Lu

    2014-01-01

    Full Text Available The flow characteristic of exhaust system has an important impact on inlet boundary of the turbine. In this paper, high speed flow in a diesel exhaust manifold junction was tested and simulated. The pressure loss coefficient of the junction flow was analyzed. The steady experimental results indicated that both of static pressure loss coefficients L13 and L23 first increased and then decreased with the increase of mass flow ratio of lateral branch and public manifold. The total pressure loss coefficient K13 always increased with the increase of mass flow ratio of junctions 1 and 3. The total pressure loss coefficient K23 first increased and then decreased with the increase of mass flow ratio of junctions 2 and 3. These pressure loss coefficients of the exhaust pipe junctions can be used in exhaust flow and turbine inlet boundary conditions analysis. In addition, simulating calculation was conducted to analyze the effect of branch angle on total pressure loss coefficient. According to the calculation results, total pressure loss coefficient was almost the same at low mass flow rate of branch manifold 1 but increased with lateral branch angle at high mass flow rate of branch manifold 1.

  8. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available.

  9. In vitro preliminary cytotoxicity testing of vegetal extracts, using colorimetric methods

    Directory of Open Access Journals (Sweden)

    Claudia Patricia Cordero Camacho

    2011-12-01

    Full Text Available To advance in the study of the Colombian vegetal biodiversity, considered as a potential source of pharmacologically active products, the establishment of biological activity evaluation systems is necessary, which allow the detection of active products against pathologies with high social and economical impact, such as cancer. This work describes the implementation of a preliminary in vitro methodology for the determination of potential anticancer activity in vegetal extracts, by cytotoxicity testing upon human tumor cell lines, measuring the cellular mass indirectly with the colorimetric assays of MTT (methyl tetrazolium tiazole reduction and SRB (sulforhodamine Bstaining. HT-29, MCF-7, SiHa and HEp-2 cell lines cultures were adapted, MTT concentration, cellular density and treatment period parameters for the cytotoxicity assay were selected. Cell lines sensitivity to the chemotherapeutic agent Doxorubicin HCl was determined. Colombian vegetal species extracts cytotoxicity was tested and usefulness of the assay as a tool to bioguide the search of active products was evidenced.

  10. Integral Test Facility PKL: Experimental PWR Accident Investigation

    Directory of Open Access Journals (Sweden)

    Klaus Umminger

    2012-01-01

    Full Text Available Investigations of the thermal-hydraulic behavior of pressurized water reactors under accident conditions have been carried out in the PKL test facility at AREVA NP in Erlangen, Germany for many years. The PKL facility models the entire primary side and significant parts of the secondary side of a pressurized water reactor (PWR at a height scale of 1 : 1. Volumes, power ratings and mass flows are scaled with a ratio of 1 : 145. The experimental facility consists of 4 primary loops with circulation pumps and steam generators (SGs arranged symmetrically around the reactor pressure vessel (RPV. The investigations carried out encompass a very broad spectrum from accident scenario simulations with large, medium, and small breaks, over the investigation of shutdown procedures after a wide variety of accidents, to the systematic investigation of complex thermal-hydraulic phenomena. This paper presents a survey of test objectives and programs carried out to date. It also describes the test facility in its present state. Some important results obtained over the years with focus on investigations carried out since the beginning of the international cooperation are exemplarily discussed.

  11. Extended testing of a general contextual classifier using the massively parallel processor - Preliminary results and test plans. [for thematic mapping

    Science.gov (United States)

    Tilton, J. C.

    1985-01-01

    Earlier encouraging test results of a contextual classifier that combines spatial and spectral information employing a general statistical approach are expanded. The earlier results were of limited meaning because they were produced from small (50-by-50 pixel) data sets. An implementation of the contextual classifier on NASA Goddard's Massively Parallel Processor (MPP) is presented; for the first time the MPP makes feasible the testing of the classifier on large data sets (a 12-hour test on a VAX-11/780 minicomputer now takes 5 minutes on the MPP). The MPP is a Single-Instruction, Multiple Data Stream computer, consisting of 16,384 bit serial microprocessors connected in a 128-by-128 mesh array with each element having data transfer connections with its four nearest neighbors so that the MPP is capable of billions of operations per second. Preliminary results are given (with more expected for the conference) and plans are mentioned for extended testing of the contextual classifier on Thematic Mapper data sets.

  12. Testing optimality with experimental evolution: lysis time in a bacteriophage.

    Science.gov (United States)

    Heineman, Richard H; Bull, James J

    2007-07-01

    Optimality models collapse the vagaries of genetics into simple trade-offs to calculate phenotypes expected to evolve by natural selection. Optimality approaches are commonly criticized for this neglect of genetic details, but resolution of this disagreement has been difficult. The importance of genetic details may be tested by experimental evolution of a trait for which an optimality model exists and in which genetic details can be studied. Here we evolved lysis time in bacteriophage T7, a virus of Escherichia coli. Lysis time is equivalent to the age of reproduction in an organism that reproduces once and then dies. Delaying lysis increases the number of offspring but slows generation time, and this trade-off renders the optimum sensitive to environmental conditions: earlier lysis is favored when bacterial hosts are dense, later lysis is favored when hosts are sparse. In experimental adaptations, T7 evolved close to the optimum in conditions favoring early lysis but not in conditions favoring late lysis. One of the late lysis adaptations exhibited no detectable phenotypic evolution despite genetic evolution; the other evolved only partly toward the expected optimum. Overall, the lysis time of the adapted phages remained closer to their starting values than predicted by the model. From the perspective of the optimality model, the experimental conditions were expected to select changes only along the postulated trade-off, but a trait outside the trade-off evolved as well. Evidence suggests that the model's failure ultimately stems from a violation of the trade-off, rather than a paucity of mutations.

  13. Experimental temperature measurements for the energy amplifier test

    Energy Technology Data Exchange (ETDEWEB)

    Calero, J. [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Madrid (Spain); Cennini, P. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland); Gallego, E. [Universidad Politecnica de Madrid (UPM), E-28040 Madrid (Spain); Galvez, J. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland)]|[Universidad Autonoma de Madrid (UAM), E-28049 Madrid (Spain); Garcia Tabares, L. [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Madrid (Spain); Gonzalez, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), E-28040 Madrid (Spain); Jaren, J. [Universidad Autonoma de Madrid (UAM), E-28049 Madrid (Spain); Lopez, C. [Universidad Autonoma de Madrid (UAM), E-28049 Madrid (Spain); Lorente, A. [Universidad Politecnica de Madrid (UPM), E-28040 Madrid (Spain); Martinez Val, J.M. [Universidad Politecnica de Madrid (UPM), E-28040 Madrid (Spain); Oropesa, J. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland); Rubbia, C. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland); Rubio, J.A. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland)]|[Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), E-28040 Madrid (Spain); Saldana, F. [European Laboratory for Particle Physics, CH-1211 Geneva 23 (Switzerland); Tamarit, J. [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Madrid (Spain); Vieira, S. [Universidad Autonoma de Madrid (UAM), E-28049 Madrid (Spain)

    1996-06-21

    A uranium thermometer has been designed and built in order to make local power measurements in the first energy amplifier test (FEAT). Due to the experimental conditions power measurements of tens to hundreds of nW were required, implying a sensitivity in the temperature change measurements of the order of 1 mK. A uranium thermometer accurate enough to match that sensitivity has been built. The thermometer is able to determine the absolute energetic gain obtained in a tiny subcritical uranium assembly exposed to a proton beam of kinetic energies between 600 MeV and 2.75 GeV. In addition, the thermometer measurements have provided information about the spatial power distribution and the shape of the neutron spallation cascade. (orig.).

  14. Testing experimental subunit furunculosis vaccines for rainbow trout

    DEFF Research Database (Denmark)

    Marana, Moonika H.; Chettri, Jiwan Kumar; Skov, Jakob

    2016-01-01

    Aeromonas salmonicida subsp. salmonicida (AS) is the etiological agent of typical furunculosis in salmonid fish. The disease causes bacterial septicemia and is a major fish health problem in salmonid aquaculture worldwide, inducing high morbidity and mortality. In this study we vaccinated rainbow...... trout with subunit vaccines containing protein antigens that were selected based on an in silico antigen discovery approach. Thus, the proteome of AS strain A449 was analyzed by an antigen discovery platform and its proteins consequently ranked by their predicted ability to evoke protective immune...... response against AS. Fourteen proteins were prepared in 3 different experimental subunit vaccine combinations and used to vaccinate rainbow trout by intraperitoneal (i.p.) injection. We tested the proteins for their ability to elicit antibody production and protection. Thus, fish were exposed to virulent...

  15. Experimental device-independent tests of classical and quantum dimensions

    Science.gov (United States)

    Ahrens, Johan; Badziag, Piotr; Cabello, Adán; Bourennane, Mohamed

    2012-08-01

    A fundamental resource in any communication and computation task is the amount of information that can be transmitted and processed. The classical information encoded in a set of states is limited by the number of distinguishable states or classical dimension dc of the set. The sets used in quantum communication and information processing contain states that are neither identical nor distinguishable, and the quantum dimension dq of the set is the dimension of the Hilbert space spanned by these states. An important challenge is to assess the (classical or quantum) dimension of a set of states in a device-independent way, that is, without referring to the internal working of the device generating the states. Here we experimentally test dimension witnesses designed to efficiently determine the minimum dimension of sets of (three or four) photonic states from the correlations originated from measurements on them, and distinguish between classical and quantum sets of states.

  16. Spatiotemporal properties of microsaccades: Model predictions and experimental tests

    Science.gov (United States)

    Zhou, Jian-Fang; Yuan, Wu-Jie; Zhou, Zhao

    2016-10-01

    Microsaccades are involuntary and very small eye movements during fixation. Recently, the microsaccade-related neural dynamics have been extensively investigated both in experiments and by constructing neural network models. Experimentally, microsaccades also exhibit many behavioral properties. It’s well known that the behavior properties imply the underlying neural dynamical mechanisms, and so are determined by neural dynamics. The behavioral properties resulted from neural responses to microsaccades, however, are not yet understood and are rarely studied theoretically. Linking neural dynamics to behavior is one of the central goals of neuroscience. In this paper, we provide behavior predictions on spatiotemporal properties of microsaccades according to microsaccade-induced neural dynamics in a cascading network model, which includes both retinal adaptation and short-term depression (STD) at thalamocortical synapses. We also successfully give experimental tests in the statistical sense. Our results provide the first behavior description of microsaccades based on neural dynamics induced by behaving activity, and so firstly link neural dynamics to behavior of microsaccades. These results indicate strongly that the cascading adaptations play an important role in the study of microsaccades. Our work may be useful for further investigations of the microsaccadic behavioral properties and of the underlying neural dynamical mechanisms responsible for the behavioral properties.

  17. The BNL Accelerator Test Facility and experimental program

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, I. (Brookhaven National Lab., Upton, NY (United States) State Univ. of New York, Stony Brook, NY (United States). Dept. of Physics)

    1991-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high power laser pulses synchronized to the electron beam, suitable for studies of new methods of high gradient acceleration and state of the art free electron lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 to 100 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps Nd:YAG laser and a 100 mJ, 10 ps CO{sub 2} laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various acceleration schemes, Free-Electron Laser experiments and a program on the development of high brightness electron beams. The AFT's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the High power laser will begin operation this year. 28 refs., 4 figs.

  18. The BNL Accelerator Test Facility and experimental program

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, I. [Brookhaven National Lab., Upton, NY (United States)]|[State Univ. of New York, Stony Brook, NY (United States). Dept. of Physics

    1992-09-01

    The Accelerator Test Facility (ATF) at BNL is a users` facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0{sub 2} laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF`s experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year.

  19. The BNL Accelerator Test Facility and experimental program

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, I. (Brookhaven National Lab., Upton, NY (United States) State Univ. of New York, Stony Brook, NY (United States). Dept. of Physics)

    1992-01-01

    The Accelerator Test Facility (ATF) at BNL is a users' facility for experiments in Accelerator and Beam Physics. The ATF provides high brightness electron beams and high-power laser pulses synchronized to the electron beam, suitable for studies of new methods of high-gradient acceleration and state-of-the-art Free-Electron Lasers. The electrons are produced by a laser photocathode rf gun and accelerated to 50 MeV by two traveling wave accelerator sections. The lasers include a 10 mJ, 10 ps ND:YAG laser and a 500 mJ, 10 to 100 ps C0{sub 2} laser. A number of users from National Laboratories, universities and industry take part in experiments at the ATF. The experimental program includes various laser acceleration schemes, Free-Electron Laser experiments and a program on the development of high-brightness electron beams. The ATF's experimental program commenced in early 1991 at an energy of about 4 MeV. The full program, with 50 MeV and the high-power laser will begin operation this year.

  20. Preliminary study of an immunochromatography test for serological diagnosis of canine brucellosis.

    Science.gov (United States)

    Wanke, M M; Cairó, F; Rossano, M; Laiño, M; Baldi, P C; Monachesi, N E; Comercio, E A; Vivot, M M

    2012-12-01

    The most widely used screening test for the diagnosis of brucellosis in the dog is the rapid slide agglutination test in the presence of 2-mercaptoethanol (2ME-RSAT). The diagnosis is partially confirmed by the agar gel immunodiffusion test (AGID) and definitively confirmed by bacteriological isolation. Some chronic cases not detected by these tests may be detected by ELISA tests. The use of 2ME-RSAT in routine clinical practice requires a microscope and an experienced operator. An immunochromatographic diagnostic test for canine brucellosis (FASTest(®) Brucella c., Megacor, Hörbranz, Austria) has been recently released. In this study, we compared the diagnostic performance of the FASTest with those of 2ME-RSAT, AGID and ELISAs. Sera from 17 healthy dogs used as negative controls yielded negative results by FASTest, indicating a 100% specificity in this sample. Among 27 sera of dogs with acute or subacute brucellosis confirmed by B. canis isolation, all of which were positive by RSAT and ELISAs, the FASTest was positive in 24 cases and AGID in 23. In acute and subacute cases, the sensitivity of FASTest was 89%. Sera from six dogs with bacteriologically confirmed chronic brucellosis, which were positive by ELISAs but negative by 2ME-RSAT, were also tested; 1 was positive by FASTest and 4 were positive by AGID. These preliminary results indicate a good specificity of the FASTest (100% in this sample) but an unacceptable sensitivity as a screening test. In cases with chronic brucellosis, the sensitivity of the FASTest was lower than that of ELISAs but this assay could make a good intermediate test to be run after a positive RSAT and before running an AGID.

  1. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    Science.gov (United States)

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  2. The Experimental Regional Ensemble Forecast System (ExREF): Its Use in NWS Forecast Operations and Preliminary Verification

    Science.gov (United States)

    Reynolds, David; Rasch, William; Kozlowski, Daniel; Burks, Jason; Zavodsky, Bradley; Bernardet, Ligia; Jankov, Isidora; Albers, Steve

    2014-01-01

    The Experimental Regional Ensemble Forecast (ExREF) system is a tool for the development and testing of new Numerical Weather Prediction (NWP) methodologies. ExREF is run in near-realtime by the Global Systems Division (GSD) of the NOAA Earth System Research Laboratory (ESRL) and its products are made available through a website, an ftp site, and via the Unidata Local Data Manager (LDM). The ExREF domain covers most of North America and has 9-km horizontal grid spacing. The ensemble has eight members, all employing WRF-ARW. The ensemble uses a variety of initial conditions from LAPS and the Global Forecasting System (GFS) and multiple boundary conditions from the GFS ensemble. Additionally, a diversity of physical parameterizations is used to increase ensemble spread and to account for the uncertainty in forecasting extreme precipitation events. ExREF has been a component of the Hydrometeorology Testbed (HMT) NWP suite in the 2012-2013 and 2013-2014 winters. A smaller domain covering just the West Coast was created to minimize band-width consumption for the NWS. This smaller domain has and is being distributed to the National Weather Service (NWS) Weather Forecast Office and California Nevada River Forecast Center in Sacramento, California, where it is ingested into the Advanced Weather Interactive Processing System (AWIPS I and II) to provide guidance on the forecasting of extreme precipitation events. This paper will review the cooperative effort employed by NOAA ESRL, NASA SPoRT (Short-term Prediction Research and Transition Center), and the NWS to facilitate the ingest and display of ExREF data utilizing the AWIPS I and II D2D and GFE (Graphical Software Editor) software. Within GFE is a very useful verification software package called BoiVer that allows the NWS to utilize the River Forecast Center's 4 km gridded QPE to compare with all operational NWP models 6-hr QPF along with the ExREF mean 6-hr QPF so the forecasters can build confidence in the use of the

  3. Preliminary study fo the interference of proteic compounds of radiopharmaceuticals in the test of lisadode amebocitos de limulus (LAL)

    CERN Document Server

    Aldana, C

    1997-01-01

    In this thesis the objective was evaluate the interference of proteic compounds of the radiopharmaceuticals in the test LAL (lisado of amebocitos de limulus) for this, macroagregates of albumina (MAA) was used with metilendifosfonato (MDP) as control that is the radiopharmaceutical more used in the nuclear medicine centers of the country. Initially preliminary test were carried out to assess if some of two radiopharmaceuticals would cause interference with LAL test, after the test was validated and finally routine tests were made. With the preliminary assays was concluded that proteic compounds did not cause interference (albumina with a concentration of 2 md/dl) with the MAA. However with the MDP cause interference with LAL test. The interference was eliminated with a dilution of 1:8 of the sample. Was concluded that the success of LAL test depends on conditions such as temperature, pH, constant incubation (no minimum variations) and that is a good test for quality control of the radiopharmaceuticals.

  4. Experimental impact testing and analysis of composite fan cases

    Science.gov (United States)

    Vander Klok, Andrew Joe

    For aircraft engine certification, one of the requirements is to demonstrate the ability of the engine to withstand a fan blade-out (FBO) event. A FBO event may be caused by fatigue failure of the fan blade itself or by impact damage of foreign objects such as bird strike. An un-contained blade can damage flight critical engine components or even the fuselage. The design of a containment structure is related to numerous parameters such as the blade tip speed; blade material, size and shape; hub/tip diameter; fan case material, configuration, rigidity, etc. To investigate all parameters by spin experiments with a full size rotor assembly can be prohibitively expensive. Gas gun experiments can generate useful data for the design of engine containment cases at much lower costs. To replicate the damage modes similar to that on a fan case in FBO testing, the gas gun experiment has to be carefully designed. To investigate the experimental procedure and data acquisition techniques for FBO test, a low cost, small spin rig was first constructed. FBO tests were carried out with the small rig. The observed blade-to-fan case interactions were similar to those reported using larger spin rigs. The small rig has the potential in a variety of applications from investigating FBO events, verifying concept designs of rotors, to developing spin testing techniques. This rig was used in the developments of the notched blade releasing mechanism, a wire trigger method for synchronized data acquisition, high speed video imaging and etc. A relationship between the notch depth and the release speed was developed and verified. Next, an original custom designed spin testing facility was constructed. Driven by a 40HP, 40,000rpm air turbine, the spin rig is housed in a vacuum chamber of phi72inx40in (1829mmx1016mm). The heavily armored chamber is furnished with 9 viewports. This facility enables unprecedented investigations of FBO events. In parallel, a 15.4ft (4.7m) long phi4.1inch (105mm

  5. Experimental Program for the CLIC test facility 3 test beam line

    CERN Document Server

    Adli, E; Dobert, S; Olvegaard, M; Schulte, D; Syratchev, I; Lillestol, Reidar

    2010-01-01

    The CLIC Test Facility 3 Test Beam Line is the first prototype for the CLIC drive beam decelerator. Stable transport of the drive beam under deceleration is a mandatory component in the CLIC two-beam scheme. In the Test Beam Line more than 50% of the total energy will be extracted from a 150 MeV, 28 A electron drive beam, by the use of 16 power extraction and transfer structures. A number of experiments are foreseen to investigate the drive beam characteristics under deceleration in the Test Beam Line, including beam stability, beam blow up and the efficiency of the power extraction. General benchmarking of decelerator simulation and theory studies will also be performed. Specially designed instrumentation including precision BPMs, loss monitors and a time-resolved spectrometer dump will be used for the experiments. This paper describes the experimental program foreseen for the Test Beam Line, including the relevance of the results for the CLIC decelerator studies.

  6. Comparison of different experimental techniques used for wax deposition testing

    Energy Technology Data Exchange (ETDEWEB)

    Allenson, Stephen; Johnston, Angela [Nalco Energy Services, Sugar Land, TX (United States)

    2008-07-01

    Crude oils consist of various fractions of hydrocarbons, including n-paraffins. The paraffins precipitate out of oil below the temperature called WAT (wax appearance temperature) and accumulate in flow lines and pipelines causing major transport problems. Prediction of paraffin deposition is, therefore, a key element of flow assurance programs. The purpose of this study was to develop a general and reliable approach to prediction of wax deposition based on a critical comparison of several practical lab techniques. Wax deposition study was conducted on five separate crude oils by using a varying protocols and equipment. One experimental technique was a cold stress test of wax deposition combined with ketone precipitation of waxy paraffin crystals. Another set of experiments were carried out for wax deposits formed on the surface of U-tubes and cold fingers of different designs. A comparison of the effectiveness of several wax inhibitors was conducted for these crude oils by using the selected deposition techniques. In each test method the amount of precipitated wax was recorded and compared. The deposits were characterized by melting point, qualitative and quantitative analysis of the wax components using DSC, SARA and HTGC analyses. Efficiency of paraffin inhibitors was correlated with a profile of n-paraffins distribution in the deposits. The limitations and advantages of different deposition techniques were analyzed and discussed. (author)

  7. Experimental facility for testing nuclear instruments for planetary landing missions

    Science.gov (United States)

    Golovin, Dmitry; Mitrofanov, Igor; Litvak, Maxim; Kozyrev, Alexander; Sanin, Anton; Vostrukhin, Andrey

    2017-04-01

    The experimental facility for testing and calibration of nuclear planetology instruments has been built in the frame of JINR and Space Research Institute (Moscow) cooperation. The Martian soil model from silicate glass with dimensions 3.82 x 3.21 m and total weight near 30 tons has been assembled in the facility. The glass material was chosen for imitation of dry Martian regolith. The heterogeneous model has been proposed and developed to achieve the most possible similarity with Martian soil in part of the average elemental composition by adding layers of necessary materials, such as iron, aluminum, and chlorine. The presence of subsurface water ice is simulated by adding layers of polyethylene at different depths inside glass model assembly. Neutron generator was used as a neutron source to induce characteristic gamma rays for testing active neutron and gamma spectrometers to define elements composition of the model. The instrumentation was able to detect gamma lines attributed to H, O, Na, Mg, Al, Si, Cl, K, Ca and Fe. The identified elements compose up to 95 wt % of total mass of the planetary soil model. This results will be used for designing scientific instruments to performing experiments of active neutron and gamma ray spectroscopy on the surface of the planets during Russian and international missions Luna-Glob, Luna-Resource and ExoMars-2020.

  8. Preliminary piping layout and integration of European test blanket modules subsystems in ITER CVCS area

    Energy Technology Data Exchange (ETDEWEB)

    Tarallo, Andrea, E-mail: andrea.tarallo@unina.it [CREATE, University of Naples Federico II, DII, P.le Tecchio, 80, 80125 Naples (Italy); Mozzillo, Rocco; Di Gironimo, Giuseppe [CREATE, University of Naples Federico II, DII, P.le Tecchio, 80, 80125 Naples (Italy); Aiello, Antonio; Utili, Marco [ENEA UTIS, C.R. Brasimone, Bacino del Brasimone, I-40032 Camugnano, BO (Italy); Ricapito, Italo [TBM& MD Project, Fusion for Energy, EU Commission, Carrer J. Pla, 2, Building B3, 08019 Barcelona (Spain)

    2015-04-15

    Highlights: • The use of human modeling tools for piping design in view of maintenance is discussed. • A possible preliminary layout for TBM subsystems in CVCS area has been designed with CATIA. • A DHM-based method to quickly check for maintainability of piping systems is suggested. - Abstract: This paper explores a possible integration of some ancillary systems of helium-cooled lithium lead (HCLL) and helium-cooled pebble-bed (HCPB) test blanket modules in ITER CVCS area. Computer-aided design and ergonomics simulation tools have been fundamental not only to define suitable routes for pipes, but also to quickly check for maintainability of equipment and in-line components. In particular, accessibility of equipment and systems has been investigated from the very first stages of the design using digital human models. In some cases, the digital simulations have resulted in changes in the initial space reservations.

  9. Preliminary safety evaluation (PSE) for Sodium Storage Facility at the Fast Flux Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, B.R.

    1994-09-30

    This evaluation was performed for the Sodium Storage Facility (SSF) which will be constructed at the Fast Flux Test Facility (FFTF) in the area adjacent to the South and West Dump Heat Exchanger (DHX) pits. The purpose of the facility is to allow unloading the sodium from the FFTF plant tanks and piping. The significant conclusion of this Preliminary Safety Evaluation (PSE) is that the only Safety Class 2 components are the four sodium storage tanks and their foundations. The building, because of its imminent risk to the tanks under an earthquake or high winds, will be Safety Class 3/2, which means the building has a Safety Class 3 function with the Safety Class 2 loads of seismic and wind factored into the design.

  10. The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2.

    Science.gov (United States)

    Efremov, A; Bekhterev, V; Bogomolov, S; Drobin, V; Loginov, V; Lebedev, A; Yazvitsky, N; Yakovlev, B

    2012-02-01

    A new compact version of the "liquid He-free" superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

  11. Test plan for preliminary study of inorganic contaminant removal from RMA groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, D.; Terkonda, P.; Weeks, N.

    1978-02-01

    This document consists of a major report on inorganic contaminant removal from ground water. In this plan, WES has been requested by the OPM-CDIR to conduct a literature review and preliminary laboratory treatability studies on various source waters at RMA. Recommendation is that the determination of suitable treatment processes be based on both engineering and economic analysis and that the processes be compatible with the organic contaminant treatment processes under study (activated carbon adsorption and ultraviolet/ozone oxidation). The amendment to the test plan presents the inorganic treatment processes found from the literature to be applicable to the inorganic contaminants in RMA ground water and outlines the bench scale study to be conducted at WES using the potential processes. The rest of the document is correspondence and reports on various water treatability.

  12. Developing the Psychological Strain Scales (PSS): Reliability, Validity, and Preliminary Hypothesis Tests.

    Science.gov (United States)

    Zhang, Jie; Lu, Juncheng; Zhao, Sibo; Lamis, Dorian A; Li, Ning; Kong, Yuanyuan; Jia, Cunxian; Zhou, Li; Ma, Zhenyu

    2014-01-01

    Since its inception, the Strain Theory of Suicide has been tested and supported in a number of empirical studies. This social psychological theory can be employed as a complementary conceptualization to account for suicidal behaviors as well as mental disorders. However, the lack of consistent measurements of the strains limits the application of the theory in scientific research. Our research team has developed such scales for future testing of the Strain Theory of Suicide in a more systematic approach. For the initial items to measure the four strains (value, aspiration, deprivation, and coping), we solicited approximately 40 items for each strain with high face validity by about 30 fellow researchers. A preliminary examination of about 160 items for consistency and validity, with a sample of about 300 college students, yielded 20 consistent items for each of the four strain scales. Then, a second study was conducted at a different university with approximately 500 students to further streamline each of the four strain scales and test the validity of each with corresponding established scales and variables. As a result, 15 items were selected for each of the four Psychological Strain Scales (PSS). In correlation and multiple regression analyses, we found support for the hypotheses regarding the positive associations between psychological strains measured by the PSS and psychopathology including suicidal ideation. Follow up research with the new scales needs to be carried out in order to test the effects of psychological strains on suicide and mental disorders for various populations.

  13. InChIKey collision resistance: an experimental testing

    Directory of Open Access Journals (Sweden)

    Pletnev Igor

    2012-12-01

    Full Text Available Abstract InChIKey is a 27-character compacted (hashed version of InChI which is intended for Internet and database searching/indexing and is based on an SHA-256 hash of the InChI character string. The first block of InChIKey encodes molecular skeleton while the second block represents various kinds of isomerism (stereo, tautomeric, etc.. InChIKey is designed to be a nearly unique substitute for the parent InChI. However, a single InChIKey may occasionally map to two or more InChI strings (collision. The appearance of collision itself does not compromise the signature as collision-free hashing is impossible; the only viable approach is to set and keep a reasonable level of collision resistance which is sufficient for typical applications. We tested, in computational experiments, how well the real-life InChIKey collision resistance corresponds to the theoretical estimates expected by design. For this purpose, we analyzed the statistical characteristics of InChIKey for datasets of variable size in comparison to the theoretical statistical frequencies. For the relatively short second block, an exhaustive direct testing was performed. We computed and compared to theory the numbers of collisions for the stereoisomers of Spongistatin I (using the whole set of 67,108,864 isomers and its subsets. For the longer first block, we generated, using custom-made software, InChIKeys for more than 3 × 1010 chemical structures. The statistical behavior of this block was tested by comparison of experimental and theoretical frequencies for the various four-letter sequences which may appear in the first block body. From the results of our computational experiments we conclude that the observed characteristics of InChIKey collision resistance are in good agreement with theoretical expectations.

  14. A hybrid passive localization method under strong interference with a preliminary experimental demonstration

    Science.gov (United States)

    Lei, Bo; Yang, Yixin; Yang, Kunde; Wang, Yong; Shi, Yang

    2016-12-01

    Strong interference exists in many passive localization problems and may lead to the inefficacy of traditional localization methods. In this study, a hybrid passive localization method is proposed to address strong interference. This method combines generalized cross-correlation and interference cancellation for time-difference-of-arrival (TDOA) measurement, followed by a time-delay-based iterative localization method. The proposed method is applied to a preliminary experiment using three hydrophones. The TDOAs estimated by the proposed method are compared with those obtained by the particle filtering method. Results show that the positions are in agreement when the TDOAs are accurately obtained. Furthermore, the proposed method is more capable of localization in the presence of a strong moving jamming source.

  15. Preliminary checklist of fungi of the Fernow Experimental Forest. Forest Service general technical report (Final)

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, S.L.; Kumar, A.; Bhatt, R.; Dubey, T.; Landolt, J.C.

    1994-01-01

    The report provides a checklist of fungi found on the Fernow Experimental Forest in West Virginia during 4 years of research and collecting by the authors. More than 500 fungi in seven major taxonomic groups (Acrasiomycetes, Myxomycetes, Chytridiomycetes, Oomycetes, Ascomycetes, Deuteromycetes, and Basidiomycetes) are listed alphabetically by genus and species. Also provided is a general description of the forest vegetation of the Fernow Experimental Forest.

  16. Thermodynamic testing of experimental hornfels formation in metapelites

    Science.gov (United States)

    Tropper, Peter

    2016-04-01

    pseudosection calculations. This discrepancy varies between 30°C and 110°C and could be due to minor F and/or Cl contents in the micas which we did not analyse. Major mineral chemical trends could also satisfactorely be reproduced except for Ti-contents in biotite. Overall the results indicate actually satisfactorial agreement between the observed and thermodynamically stable mineral assemblages but some discrepancies still occur which are mostly due to kinetical reasons (complete old garnet resorption did not take place, inhibited growth of andalusite). Nonetheless these whole-rock experiments provide valuable information concerning the textural evolution of the natural hornfelses and thermodynamic testing not only helps to constrain equilibrium assemblages but also helps identifying certain non-equilibrium features in the experiments otherwise not detected (e.g. garnet, muscovite stability). The ultimate goal in constraining the metamorphic evolution of these high-grade hornfelses is to reconcile the experimental- and thermodynamic data with field- and petrographic observations. Only this comprehensive approach allows then drawing firm conclusions about the evolution of these high-grade metamorphic rocks. De Capitani, C. & Petrakakis, K. (2010): American Mineralogist, 95, 1006-1016. Holland, T. J. B. & Powell, R. (1998): Journal of Metamorphic Geology, 8, 89-124. White, R.W., Powell, R. & Holland, T.J.B. (2007): Journal of Metamorphic Geology, 25, 511-527. White, R.W., Powell, R. & Holland, T.J.B. (2001): Journal of Metamorphic Geology, 19, 139-153. Wyhlidal, S. et al. (2012): Mineralogy and Petrology, 106, 173-191. Zöll, K. (2014): Unpublished M.Sc. Thesis, University of Innsbruck.

  17. Experimental design in phylogenetics: testing predictions from expected information.

    Science.gov (United States)

    San Mauro, Diego; Gower, David J; Cotton, James A; Zardoya, Rafael; Wilkinson, Mark; Massingham, Tim

    2012-07-01

    Taxon and character sampling are central to phylogenetic experimental design; yet, we lack general rules. Goldman introduced a method to construct efficient sampling designs in phylogenetics, based on the calculation of expected Fisher information given a probabilistic model of sequence evolution. The considerable potential of this approach remains largely unexplored. In an earlier study, we applied Goldman's method to a problem in the phylogenetics of caecilian amphibians and made an a priori evaluation and testable predictions of which taxon additions would increase information about a particular weakly supported branch of the caecilian phylogeny by the greatest amount. We have now gathered mitogenomic and rag1 sequences (some newly determined for this study) from additional caecilian species and studied how information (both expected and observed) and bootstrap support vary as each new taxon is individually added to our previous data set. This provides the first empirical test of specific predictions made using Goldman's method for phylogenetic experimental design. Our results empirically validate the top 3 (more intuitive) taxon addition predictions made in our previous study, but only information results validate unambiguously the 4th (less intuitive) prediction. This highlights a complex relationship between information and support, reflecting that each measures different things: Information is related to the ability to estimate branch length accurately and support to the ability to estimate the tree topology accurately. Thus, an increase in information may be correlated with but does not necessitate an increase in support. Our results also provide the first empirical validation of the widely held intuition that additional taxa that join the tree proximal to poorly supported internal branches are more informative and enhance support more than additional taxa that join the tree more distally. Our work supports the view that adding more data for a single (well

  18. An experimental test of whether habitat corridors affect pollen transfer.

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Patricia A.; Levey, Douglas J.

    2005-02-01

    Abstract. Negative effects of habitat fragmentation are thought to be diminished when habitat patches are joined by a corridor. A key assumption is that corridors facilitate exchange rates of organisms between otherwise isolated patches. If the organisms are pollinators, corridors may be important for maintaining genetically viable populations of the plants that they pollinate. We tested the hypothesis that corridors increase the movement of insect pollinators into patches of habitat and thereby increase pollen transfer for two species of plants, one pollinated by butterflies (Lantana camara) and the other by bees and wasps (Rudbeckia hirta). We worked in an experimental landscape consisting of 40 greater than or equal to 1-ha patches of early-successional habitat in a matrix of forest. Within each of eight experimental units, two patches were connected by a corridor (150 X 25 m), and three were not. Patch shape varied to control for the area added by the presence of a corridor. Differences in patch shape also allowed us to test alternative hypotheses of how corridors might function. The Traditional Corridor Hypothesis posits that corridors increase immigration and emigration by functioning as movement conduits between patches. The Drift Fence Hypothesis posits that corridors function by ‘‘capturing’’ organisms dispersing through the matrix, redirecting them into associated habitat patches. Using fluorescent powder to track pollen, we found that pollen transfer by butterflies between patches connected by a corridor was significantly higher than between unconnected patches (all values mean plus or minus 1 SE: 59% plus or minus 9.2% vs. 25% plus or minus 5.2% of flowers receiving pollen). Likewise, pollen transfer by bees and wasps was significantly higher between connected patches than between unconnected patches (30% plus or minus 4.2% vs. 14.5% plus or minus 2.2%). These results support the Traditional Corridor Hypothesis. There was little support, however

  19. Clinical evaluation of children testing positive in screening tests for attention-deficit/hyperactivity disorder: A preliminary report

    Directory of Open Access Journals (Sweden)

    Maria Skounti

    2009-06-01

    Full Text Available Background and Objectives: Screening tests are of great diagnostic value in attention-deficit/hyperactivity disorder (ADHD, however final diagnosis relies on a clinical examination by an expert. The objective of the present study was to clinically evaluate children who had been screened positive for ADHD through both a parent and a teacher questionnaire. Methods: Parent interview and child behavior checklist and clinical assessment were used to confirm the preliminary diagnosis in 42 children aged 8 years, who have been screened positive for ADHD out of 1,708 children, in a large, two-setting screening study conducted in Crete, Greece. Results: The diagnosis of ADHD was confirmed for 31 children (74%. In the remaining 11 children, ADHD manifestations were attributed to other primary disorders. None of the 42 children was classified as lacking symptoms suggesting ADHD. Among the 31 children with confirmed ADHD, only 2 had been diagnosed prior to the screening test. Conclusions: Although clinical evaluation is the golden standard for diagnosis of ADHD, two-setting screening questionnaires by parent and teacher are useful tools in identifying children who need further investigation and intervention.

  20. Cross-cultural effects on IQ test performance: a review and preliminary normative indications on WAIS-III test performance.

    Science.gov (United States)

    Shuttleworth-Edwards, Ann B; Kemp, Ryan D; Rust, Annegret L; Muirhead, Joanne G L; Hartman, Nigel P; Radloff, Sarah E

    2004-10-01

    This article presents a review of cross-cultural influences on Wechsler IQ tests, together with a preliminary investigation into WAIS-III test performance (English administration) for a southern African sample (age range 19-30) stratified for white English first language and black African first language, level and quality of education. ('African language' is the term used to denote the indigenous languages of black populations in southern Africa). A two-way ANOVA revealed highly significant effects for both level and quality of education within the black African first language group. Scores for the white English and black African first language groups with advantaged education were comparable with the US standardization, whereas scores for black African first language participants with disadvantaged education were significantly lower than this. Thus indications from this research are that normative studies should take account of the influential variable of quality of education, in addition to level of education. Alternatively faulty conclusions may be drawn about the effects of ethnicity, with the potential for neuropsychological misdiagnosis.

  1. Preliminary Tests Concerning Zero-Valent Iron Efficiency in Inorganic Pollutants Remediation

    Directory of Open Access Journals (Sweden)

    Silvia Fiore

    2009-01-01

    Full Text Available Problem statement: This study was aimed to a preliminary evaluation of the applicability of granular Zero-Valent Iron (ZVI to the on site remediation of groundwater polluted by inorganic contaminants by means of a Permeable Reactive Barrier (PRB. A particular interest was devoted to groundwater impacted by Acid Mine Drainage (AMD that was caused by the oxidation of metal sulphide minerals contained in mine wastes, especially iron disulphide pyrite. Although AMD consequences were particularly evident in surface waters, the percolation through mine wastes may heavily alter the groundwater quality, therefore is particularly important the development of a restrained cost remediation technique for groundwater polluted by AMDs. Approach: In this study the degradation efficiency of Brown size 8/50 ZVI (Peerless Powders and Abrasive Inc., Detroit, US was evaluated performing a leaching column test and analyzing the Oxidation Reduction Potential (ORP, metals, nitrates, chlorides and sulphates profiles along the column. Results: This test allowed simulating the solid-liquid contact characteristic of a real PRB behavior that proved to be a possible solution for the remediation of inorganic pollutants in groundwater. Conclusion: The considered material showed efficiency above 99% in metals removal, although further tests, involving biotic processes and more reducing conditions, are necessary to improve the degradation of sulphates and nitrates.

  2. VIP 2: Experimental tests of the Pauli Exclusion Principle for electrons

    CERN Document Server

    Pichler, A; Bazzi, M.; Bertolucci, S.; Berucci, C.; Bragadireanu, M.; Cargnelli, M.; Clozza, A.; Curceanu, C.; De Paolis, L.; Di Matteo, S.; D'Uffizi, A.; Egger, J.-P.; Guaraldo, C.; Iliescu, M.; Ishiwatari, T.; Laubenstein, M.; Marton, J.; Milotti, E.; Pietreanu, D.; Piscicchia, K.; Ponta, T.; Sbardella, E.; Scordo, A.; Shi, H.; Sirghi, D.; Sirghi, F.; Sperandio, L.; Vazquez-Doce, O.; Widmann, E.; Zmeskal, J.

    2015-01-01

    The Pauli Exclusion Principle (PEP) was famously discovered in 1925 by the austrian physicist Wolfgang Pauli. Since then, it underwent several experimental tests. Starting in 2006, the VIP (Violation of the Pauli Principle) experiment looked for 2p to 1s X-ray transitions in copper, where 2 electrons are present in the 1s state before the transition happens. These transitions violate the PEP, and the lack of detection of the corresponding X-ray photons lead to a preliminary upper limit for the violation of the PEP of 4.7 * 10^(-29). The follow-up experiment VIP 2 is currently in the testing phase and will be transported to its final destination, the underground laboratory of Gran Sasso in Italy, in autumn 2015. Several improvements compared to its predecessor like the use of new X-ray detectors and active shielding from background gives rise to a goal for the improvement of the upper limit of the probability for the violation of the Pauli Exclusion Principle of 2 orders of magnitude.

  3. Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Groza, Voicu; Isleifsson, Fridrik Rafn

    2012-01-01

    Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads......Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads...

  4. Environmental testing of an experimental digital safety channel

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Tanaka, T.J.; Wilson, T.L. Jr.; Wood, R.T.

    1996-09-01

    This document presents the results of environmental stress tests performed on an experimental digital safety channel (EDSC) assembled at the Oak Ridge National Laboratory (ORNL) as part of the NRC-sponsored Qualification of Advanced Instrumentation and Controls (W) System program. The objective of this study is to investigate failure modes and vulnerabilities of microprocessor-based technologies when subjected to environmental stressors. The study contributes to the technical basis for environmental qualification of safety-related digital I&C systems. The EDSC employs technologies and digital subsystems representative of those proposed for use in advanced light-water reactors (ALWRs) or for retrofits in existing plants. Subsystems include computers, electrical and optical serial communication links, fiber-optic network links, analog-to-digital and digital-to-analog converters, and multiplexers. The EDSC was subjected to selected stressors that are a potential risk to digital equipment in a mild environment. The selected stressors were electromagnetic and radio-frequency interference (EMYRFI), temperature, humidity, and smoke exposure. The stressors were applied over ranges that were considerably higher than what the channel is likely to experience in a normal nuclear power plant environment. Ranges of stress were selected at a sufficiently high level to induce errors so that failure modes that are characteristic of the technologies employed could be identified.

  5. The experimental test and analysis of 108 cases of patients with preliminary diagnosis of novel Influenza A H1N1%108例新型甲型H1N1流感患者初诊实验室检测结果分析

    Institute of Scientific and Technical Information of China (English)

    黄美群; 郑卫东; 方伟; 罗燕飞; 罗盈

    2011-01-01

    目的 探讨新型甲型H1N1 流感患者初诊实验室检测结果的特征.方法 收集该院2009年12月至2010年3月108例新型甲型H1N1 流感患者(核酸阳性)和34例季节性流感患者(核酸阴性)初诊实验室检测结果,并利用SPSS13.0软件对其进行统计分析.结果 108例新型甲型H1N1流感患者中,86.1%的患者外周血白细胞总数正常,11.1%的患者偏低,只有2.78%的患者偏高;36.1%的患者淋巴细胞计数低于正常值下限;7.4%的患者单核细胞、28.7%患者嗜碱性粒细胞计数值高于正常值上限.肝功酶类指标的检测结果分别为丙氨酸氨基转移酶(ALT)23.1%的患者、天门冬氨酸氨基转移酶(AST)20.3%的患者、γ-谷氨酰基转肽酶(GGT)22.2%的患者高于正常值上限.结论 分析新型甲型H1N1流感患者初诊时实验室检测结果的特征,有助于提高临床医生对本病流行特点以及首诊发热患者的监测和实验室检测结果特征的认识.%Objective To characterize the preliminary diagnosis of the patients are infected with influenza A ( H1N1) . Methods 108 patients with influenza A ( H1N1) (nucleic acid positive) and 34 patients with seasonal influenza (nucleic acid negative) by preliminary diagnosis were studied who were collected in our hospital during December of 2009 to March of 2010. SPSS13. 0 software were used to analyze the results. Results In 108 patients with influenza A (H1N1) .who had normal level of peripheral blood leucocytes accounted for 86. 1% (93/108) ,about 11. 1% (12/108) were lower and only 2. 78% (3/108) were higher. lyrnphocyte count below the lower limits of normal were about 36. 1% , 7. 4% of monocyte and 28. 7% of basophile granulocyte count were higher than the upper normal limit. 23. 1% (25/108) ALT,20. 3% (22/108) AST and 22. 2% (24/108) GGT were higher than the upper normal limit. Conclusion Compared with seasonal influenza patients,the group with influenza A (HINI) had lower lymphocyte

  6. Preliminary analysis of the Nocturnal Atmospheric Boundary Layer during the experimental campaign CIBA 2008

    Science.gov (United States)

    Yagüe, C.; Maqueda, G.; Ramos, D.; Sastre, M.; Viana, S.; Serrano, E.; Morales, G.; Ayarzagüena, B.; Viñas, C.; Sánchez, E.

    2009-04-01

    An Atmospheric Boundary Layer campaign was developed in Spain along June 2008 at the CIBA (Research Centre for the Lower Atmosphere) site which is placed on a fairly homogeneous terrain in the centre of an extensive plateau (41°49' N, 4°56' W). Different instrumentation at several levels was available on a new 10m meteorological mast, including temperature and humidity sensors, wind vanes and cup anemometers, as well as one sonic anemometer. Besides, two quartz-based microbarometers were installed at 50 and 100m on the main permanent 100m tower placed at CIBA. Three additional microbarometers were deployed on the surface on a triangular array of approximately 200 m side, and a tethered balloon was used in order to record vertical profiles of temperature, wind and humidity up to 1000m. Finally, a GRIMM particle monitor (MODEL 365), which can be used to continuously measure each six seconds simultaneously the PM10, PM2.5 and PM1 values, was deployed at 1.5m. This work will show some preliminary results from the campaign CIBA 2008, analysing the main physical processes present in the atmospheric Nocturnal Boundary Layer (NBL), the different stability periods observed and the corresponding turbulent parameters, as well as the coherent structures detected. The pressure perturbations measured from the surface and tower levels make possible to study the main wave parameters from wavelet transform, and compared the structures detected by the microbarometers with those detected in the wind and particles records.

  7. Chemopreventive Effects of Morindia Citrifolia Juice (noni on Experimental Breast Cancer in Rats: Preliminary Study

    Directory of Open Access Journals (Sweden)

    Ana Milena Serrano Contreras

    2014-06-01

    Full Text Available This study determines the effect of Morindia citrifolia juice (Tahitian Noni® in the development of breast cancer induced by carcinogen agent 7.12-dimethylbenzanthracene (DMBA in rats. For this purpose, the breast cancer induction model 1.7-DMBA was used on Spraguey Dawley nulliparous rats of 35 days of age, randomly divided into three groups: group 1 control, which received no treatment, and groups 2 and 3, induced with DMBA at a dose of 55 mg/kg. The latter received a dose of noni juice of 4 ml/kg per day for 90 days. The results showed that a significant percentage (83.33% of the rats from the group induced with DMBA not treated with noni juice developed palpable breast tumors ( ≤ 2 cm of the ductal carcinoma in situ type and atypical ductal hyperplasia, compared to the other groups that did not develop any kind of tumors. In addition, it was found that rats that developed breast cancer had a lower weight gain and significantly increased water consumption (p < 0.05 compared to the other two groups. The results of the hematological and biochemical parameters showed no significant changes between groups. Histopathological changes compatible with liver toxicity were found in rats treated with noni juice. In conclusion, it was found in this preliminary study that noni juice has positive effects in modulating the development of breast cancer induced by DMBA.

  8. AGR-1 Irradiated Test Train Preliminary Inspection and Disassembly First Look

    Energy Technology Data Exchange (ETDEWEB)

    Paul Demkowicz; Lance Cole; Scott Ploger; Philip Winston; Binh Pham; Michael Abbott

    2011-01-01

    The AGR-1 irradiation experiment ended on November 6, 2009, after 620 effective full power days in the Advanced Test Reactor, achieving a peak burnup of 19.6% FIMA. The test train was shipped to the Materials and Fuels Complex in March 2010 for post-irradiation examination. The first PIE activities included non-destructive examination of the test train, followed by disassembly of the test train and individual capsules and detailed inspection of the capsule contents, including the fuel compacts and the graphite fuel holders. Dimensional measurements of the compacts, graphite holders, and steel capsules shells were performed using a custom vision measurement system (for outer diameters and lengths) and conventional bore gauges (for inner diameters). Gamma spectrometry of the intact test train gave a preliminary look at the condition of the interior components. No evidence of damage to compacts or graphite components was evident from the isotopic and gross gamma scans. Neutron radiography of the intact Capsule 2 showed a high degree of detail of interior components and confirmed the observation that there was no major damage to the capsule. Disassembly of the capsules was initiated using procedures qualified during out-of-cell mockup testing. Difficulties were encountered during capsule disassembly due to irradiation-induced changes in some of the capsule components’ properties, including embrittled niobium and molybdenum parts that were susceptible to fracture and swelling of the graphite fuel holders that affected their removal from the capsule shells. This required various improvised modifications to the disassembly procedure to avoid damage to the fuel compacts. Ultimately the capsule disassembly was successful and only one compact from Capsule 4 (out of 72 total in the test train) sustained damage during the disassembly process, along with the associated graphite holder. The compacts were generally in very good condition upon removal. Only relatively minor

  9. Preliminary test of an imaging probe for nuclear medicine using hybrid pixel detectors

    CERN Document Server

    Bertolucci, Ennio; Mettivier, G; Montesi, M C; Russo, P

    2002-01-01

    We are investigating the feasibility of an intraoperative imaging probe for lymphoscintigraphy with Tc-99m tracer, for sentinel node radioguided surgery, using the Medipix series of hybrid detectors coupled to a collimator. These detectors are pixelated semiconductor detectors bump-bonded to the Medipix1 photon counting read-out chip (64x64 pixel, 170 mu m pitch) or to the Medipix2 chip (256x256 pixel, 55 mu m pitch), developed by the European Medipix collaboration. The pixel detector we plan to use in the final version of the probe is a semi-insulating GaAs detector or a 1-2 mm thick CdZnTe detector. For the preliminary tests presented here, we used 300-mu m thick silicon detectors, hybridized via bump-bonding to the Medipix1 chip. We used a tungsten parallel-hole collimator (7 mm thick, matrix array of 64x64 100 mu m circular holes with 170 mu m pitch), and a 22, 60 and 122 keV point-like (1 mm diameter) radioactive sources, placed at various distances from the detector. These tests were conducted in order ...

  10. Design and preliminary test of precision segment positioning actuator for the California Extremely Large Telescope

    Science.gov (United States)

    Lorell, Kenneth R.; Aubrun, Jean-Noel; Clappier, Robert R.; Shelef, Ben; Shelef, Gad

    2003-01-01

    In order for the California Extremely Large Telescope (CELT) to achieve the required optical performance, each of its 1000 primary mirror segments must be positioned relative to adjacent segments with nanometer-level accuracy. This can be accomplished using three actuators for each segment to actively control the segment in tip, tilt, and piston. The Keck telescopes utilize a segmented primary mirror similar to CELT employing a highly successful actuator design. However, because of its size and the shear number of actuators (3000 vs. 108 for Keck), CELT will require a different design. Sensitivity to wind loads and structural vibrations, the large dynamic range, low operating power, and extremely reliable operation, all achieved at an affordable unit cost, are the most demanding design requirements. This paper examines four actuator concepts and presents a trade-off between them. The concept that best met the CELT requirements is described along with an analysis of its performance. The concept is based on techniques that achieve the required accuracy while providing a substantial amount of vibration attenuation and damping. A prototype actuator has been built to validate this concept. Preliminary tests confirm predicted behavior and future tests will establish a sound baseline for final design and production.

  11. Preliminary failure modes and effects analysis on Korean HCCR TBS to be tested in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Mu-Young, E-mail: myahn74@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of); Jin, Hyung Gon; Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Yi-Hyun; Lee, Youngmin [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Highlights: • Postulated initiating events are identified through failure modes and effects analysis on the current HCCR TBS design. • A set of postulated initiating events are selected for consideration of deterministic analysis. • Accident evolutions on the selected postualted initiating events are qualitatively described for deterministic analysis. - Abstract: Korean Helium cooled ceramic reflector (HCCR) Test blanket system (TBS), which comprises Test blanket module (TBM) and ancillary systems in various locations of ITER building, is operated at high temperature and pressure with decay heat. Therefore, safety is utmost concern in design process and it is required to demonstrate that the HCCR TBS is designed to comply with the safety requirements and guidelines of ITER. Due to complexity of the system with many interfaces with ITER, a systematic approach is necessary for safety analysis. This paper presents preliminary failure modes and effects analysis (FMEA) study performed for the HCCR TBS. FMEA is a systematic methodology in which failure modes for components in the system and their consequences are studied from the bottom-up. Over eighty failure modes have been investigated on the HCCR TBS. The failure modes that have similar consequences are grouped as postulated initiating events (PIEs) and total seven reference accident scenarios are derived from FMEA study for deterministic accident analysis. Failure modes not covered here due to evolving design of the HCCR TBS and uncertainty in maintenance procedures will be studied further in near future.

  12. New rapid test for prenatal detection of trisomy 21 (Down's syndrome): preliminary report.

    Science.gov (United States)

    Bryndorf, T.; Christensen, B.; Philip, J.; Hansen, W.; Yokobata, K.; Bui, N.; Gaiser, C.

    1992-01-01

    OBJECTIVE--To devise and evaluate a rapid screening method for detecting trisomy 21 (Down's syndrome) in samples of uncultured amniotic fluid cells. DESIGN--Non-radioactive in situ hybridisation with HY128, a 500,000 base pair yeast artificial chromosome probe specific for chromosome 21. Blinded study of 12 karyotypically normal amniotic fluid samples and eight samples trisomic for chromosome 21. SETTING--Cytogenetic and obstetric services at a tertiary referral centre, Copenhagen. MAIN OUTCOME MEASURES--Time necessary to complete the test. Proportion of cell nuclei containing two and three hybridisation signals in karyotypically normal and abnormal amniotic fluid samples. RESULTS--The test could be completed within three to four days after amniocentesis. In the normal samples a mean of 73% (range 61-82%) of the amniotic cell nuclei showed two hybridisation signals and 6% (0-18%) showed three signals. By contrast, among the trisomic samples 29% (19-38%) of the nuclei exhibited two signals and 48% (31-60%) showed three signals. CONCLUSION--The technique clearly distinguished between normal and trisomic samples. Prenatal diagnosis with in situ hybridisation with chromosome specific probes was fast and may make it possible to screen for selected, aneuploidies. However, the technique is still at a preliminary stage and needs further evaluation and refinement. Images p1537-a PMID:1385745

  13. Individual differences in left parietal white matter predict math scores on the Preliminary Scholastic Aptitude Test.

    Science.gov (United States)

    Matejko, Anna A; Price, Gavin R; Mazzocco, Michèle M M; Ansari, Daniel

    2013-02-01

    Mathematical skills are of critical importance, both academically and in everyday life. Neuroimaging research has primarily focused on the relationship between mathematical skills and functional brain activity. Comparatively few studies have examined which white matter regions support mathematical abilities. The current study uses diffusion tensor imaging (DTI) to test whether individual differences in white matter predict performance on the math subtest of the Preliminary Scholastic Aptitude Test (PSAT). Grades 10 and 11 PSAT scores were obtained from 30 young adults (ages 17-18) with wide-ranging math achievement levels. Tract based spatial statistics was used to examine the correlation between PSAT math scores, fractional anisotropy (FA), radial diffusivity (RD) and axial diffusivity (AD). FA in left parietal white matter was positively correlated with math PSAT scores (specifically in the left superior longitudinal fasciculus, left superior corona radiata, and left corticospinal tract) after controlling for chronological age and same grade PSAT critical reading scores. Furthermore, RD, but not AD, was correlated with PSAT math scores in these white matter microstructures. The negative correlation with RD further suggests that participants with higher PSAT math scores have greater white matter integrity in this region. Individual differences in FA and RD may reflect variability in experience dependent plasticity over the course of learning and development. These results are the first to demonstrate that individual differences in white matter are associated with mathematical abilities on a nationally administered scholastic aptitude measure.

  14. Using a situational judgement test for selection into dental core training: a preliminary analysis.

    Science.gov (United States)

    Rowett, E; Patterson, F; Cousans, F; Elley, K

    2017-05-12

    Objective and setting This paper describes the evaluation of a pilot situational judgement test (SJT) for selection into UK Dental Core Training (DCT). The SJT's psychometric properties, group differences based on gender and ethnicity, and candidate reactions were assessed.Methods The SJT targets four non-academic attributes important for success in DCT. Data were collected alongside live selection processes from five Health Education England local teams in the UK (N = 386). Candidates completed the pilot SJT and an evaluation questionnaire to examine their reactions to the test.Results SJT scores were relatively normally distributed and showed acceptable levels of internal reliability (α = 0.68). Difficulty level and partial correlations between scenarios and SJT total score were in the expected ranges (64.61% to 90.03% and r = 0.06 to 0.41, respectively). No group differences were found for gender, and group differences between White and BME candidates were minimal. Most candidates perceived the SJT as relevant to the target role, appropriate and fair.Conclusions This study demonstrated the potential suitability of an SJT for use in DCT selection. Future research should replicate these preliminary findings in other cohorts, and assess the predictive validity of the SJT for predicting key training and practice-based outcomes.

  15. Comparison between a modified ethanol gelation test and protamine sulfate test. Experimental studies.

    Science.gov (United States)

    Zielinsky, A; Altman, R; Rouvier, J

    1976-08-31

    A comparative experimental study has been made to correlate the protamine sulfate test and a modified ethanol gelation test, based on clinical observations of the solubility of a gel formed at 20 degrees C (Godal and Abildgaard procedure) when it was transferred to a bath at 37 degrees C. Two different results were obtained: the gel remained insoluble at 37 degrees C or it became completely soluble, with intermediate degrees of partial solubility. Our studies indicate that this is due to the amount of fibrin monomers formed and the level of fibrinogen: the first are responsible for the insolubility of the gel and the second for its solubility. This furnishes us with useful information for diagnostic purposes. We found the protamine sulfate test more sensitive than the ethanol gelation test, and its sensitivity increased when fibrinogen level decreased. An insoluble gelation test is a sure indication of the presence of fibrin monomers, but a soluble gel calls for the protamine sulfate test to confirm this or the existence of high fibrinogen level.

  16. Deep Boreholes Seals Subjected to High P, T conditions – Preliminary Experimental Studies

    Energy Technology Data Exchange (ETDEWEB)

    Caporuscio, Florie Andre [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Norskog, Katherine Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Maner, James Lavada [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-18

    The objective of this planned experimental work is to evaluate physio-chemical processes for ‘seal’ components and materials relevant to deep borehole disposal. These evaluations will encompass multi-laboratory efforts for the development of seals concepts and application of Thermal-Mechanical-Chemical (TMC) modeling work to assess barrier material interactions with subsurface fluids, their stability at high temperatures, and the implications of these processes to the evaluation of thermal limits. Deep borehole experimental work will constrain the Pressure, Temperature (P, T) conditions which “seal” material will experience in deep borehole crystalline rock repositories. The rocks of interest to this study include the silicic (granitic gneiss) end members. The experiments will systematically add components to capture discrete changes in both water and EBS component chemistries.

  17. Wageningen Urban Rainfall Experiment 2014 (WURex14): Experimental setup and preliminary results

    Science.gov (United States)

    van Leth, Thomas C.; Uijlenhoet, Remko; Overeem, Aart; Leijnse, Hidde; Hazenberg, Pieter; Berne, Alexis

    2016-04-01

    the preliminary results.

  18. A test chamber for experimental hydrogen fluoride exposure in humans.

    Science.gov (United States)

    Søstrand, P; Kongerud, J; Eduard, W; Nilsen, T; Skogland, M; Boe, J

    1997-07-01

    An inhalation chamber was built to perform experimental studies with hydrogen fluoride (HF), other gases, and particulate matter. The present study sought to describe a new gas delivery system and the distribution and concentration of HF gas in the chamber. The aluminum chamber has a volume of 19.2 m3 and a variable ventilation rate of about 1 to 10 air changes per hour. The negative pressure difference between the chamber and outside air can be regulated from 0 to 300 Pa. HF was fed at concentrations of up to 4000 mg/m3 directly into the ventilation duct feeding the chamber through openings with diameters as small as 50 microns, oriented opposite to the airflow. Gas flow was varied from about 0.1 dm3/min at a pressure of 4 atm. The dilution factor of HF concentration from cylinder to chamber was on the order of 10(3) to 10(4). The standard deviation (SD) of the HF concentrations at a fixed measurement point during a 1-hour test was typically 0.05 mg/m3 at a time-weighted average (TWA) concentration of 2.66 mg/m3. The SD of the TWA HF concentrations at six locations in the chamber was typically 0.05 mg/m3 and 0.29 mg/m3 at 0.61 and 3.46 mg/m3, respectively. Human exposure could be predicted from calculations based on ventilation data, gas flow, and observed ratio between calculated and measured concentrations. When the target exposure concentration was 1.5 mg/m3, the measured mean exposure concentration was typically 1.54 mg/m3 (range: 1.4-1.7 mg/m3, SD 0.09 mg/m3, n = 8). The chamber is well-suited for inhalation studies in humans. Chamber atmosphere was controlled and has proved to be stable and homogeneous, even in tests with HF, a highly reactive gas in the class of superacids.

  19. A Job-Seeking Self-Efficacy Scale for People with Physical Disabilities: Preliminary Development and Psychometric Testing.

    Science.gov (United States)

    Barlow, Julie; Wright, Chris; Cullen, Lesley

    2002-01-01

    Study sought to develop and conduct preliminary testing of the psychometric properties of a job-seeking self-efficacy (JSS) scale that reflected the experiences of people with physical disabilities. Greater job seeking self-efficacy and perceived ability to manage disability at interview were associated with more positive psychological well-being.…

  20. Speech and Pause Characteristics in Multiple Sclerosis: A Preliminary Study of Speakers with High and Low Neuropsychological Test Performance

    Science.gov (United States)

    Feenaughty, Lynda; Tjaden, Kris; Benedict, Ralph H. B.; Weinstock-Guttman, Bianca

    2013-01-01

    This preliminary study investigated how cognitive-linguistic status in multiple sclerosis (MS) is reflected in two speech tasks (i.e. oral reading, narrative) that differ in cognitive-linguistic demand. Twenty individuals with MS were selected to comprise High and Low performance groups based on clinical tests of executive function and information…

  1. Design and preliminary test of a free-air ionization chamber for low-energy X-ray

    Institute of Scientific and Technical Information of China (English)

    吴金杰; 杨元第; 王培玮; 陈靖; 柳加成

    2011-01-01

    A free-air ionization chamber in low-energy X-ray has been designed and manufactured at the National Institute of Metrology (NIM, China) according to the defination of air-kerma. The results of a preliminary test show that the leakage current of ionizatio

  2. AGR-2 Irradiated Test Train Preliminary Inspection and Disassembly First Look

    Energy Technology Data Exchange (ETDEWEB)

    Ploger, Scott [Idaho National Lab. (INL), Idaho Falls, ID (United States); Demkowciz, Paul [Idaho National Lab. (INL), Idaho Falls, ID (United States); Harp, Jason [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    The AGR 2 irradiation experiment began in June 2010 and was completed in October 2013. The test train was shipped to the Materials and Fuels Complex in July 2014 for post-irradiation examination (PIE). The first PIE activities included nondestructive examination of the test train, followed by disassembly of the test train and individual capsules and detailed inspection of the capsule contents, including the fuel compacts and their graphite fuel holders. Dimensional metrology was then performed on the compacts, graphite holders, and steel capsule shells. AGR 2 disassembly and metrology were performed with the same equipment used successfully on AGR 1 test train components. Gamma spectrometry of the intact test train gave a preliminary look at the condition of the interior components. No evidence of damage to compacts or graphite components was evident from the isotopic and gross gamma scans. Disassembly of the AGR 2 test train and its capsules was conducted rapidly and efficiently by employing techniques refined during the AGR 1 disassembly campaign. Only one major difficulty was encountered while separating the test train into capsules when thermocouples (of larger diameter than used in AGR 1) and gas lines jammed inside the through tubes of the upper capsules, which required new tooling for extraction. Disassembly of individual capsules was straightforward with only a few minor complications. On the whole, AGR 2 capsule structural components appeared less embrittled than their AGR 1 counterparts. Compacts from AGR 2 Capsules 2, 3, 5, and 6 were in very good condition upon removal. Only relatively minor damage or markings were visible using high resolution photographic inspection. Compact dimensional measurements indicated radial shrinkage between 0.8 to 1.7%, with the greatest shrinkage observed on Capsule 2 compacts that were irradiated at higher temperature. Length shrinkage ranged from 0.1 to 0.9%, with by far the lowest axial shrinkage on Capsule 3 compacts

  3. [Anatomo-clinical and experimental studies on pneumocystis carinii. Preliminary note].

    Science.gov (United States)

    Christol, D; Bouton, C; Trihn, D H; Kernbaum, S

    1976-01-09

    The authors have been interested over the last year in the detection of pneumocystis carinii in patients with immune deficiencies, whether natural or artificial. After a brief historical and general introduction, they discuss their procedures, the pathological substances available, the staining techniques and the examination of autopsy specimens. They undertook experimental work on this micro-organism, e.g. the development of the germ in immuno-depressed rats and, from this material, numerous varied trials of culture and inoculation in new-born animals, chick embryos and cell cultures. Microphotographs illustrate this work which is still in progress.

  4. Experimental test of nuclear magnetization distribution and nuclear structure models

    Energy Technology Data Exchange (ETDEWEB)

    Beirsdorfer, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lopez-Urrutia, J Crespo R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Utter, S. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1999-02-26

    Models exist that ascribe the nuclear magnetic fields to the presence of a single nucleon whose spin is not neutralized by pairing it up with that of another nucleon; other models assume that the generation of the magnetic field is shared among some or all nucleons throughout the nucleus. All models predict the same magnetic field external to the nucleus since this is an anchor provided by experiments. The models differ, however, in their predictions of the magnetic field arrangement within the nucleus for which no data exist. The only way to distinguish which model gives the correct description of the nucleus would be to use a probe inserted into the nucleus. The goal of our project was to develop exactly such a probe and to use it to measure fundamental nuclear quantities that have eluded experimental scrutiny. The need for accurately knowing such quantities extends far beyond nuclear physics and has ramifications in parity violation experiments on atomic traps and the testing of the standard model in elementary particle physics. Unlike scattering experiments that employ streams of free particles, our technique to probe the internal magnetic field distribution of the nucleus rests on using a single bound electron. Quantum mechanics shows that an electron in the innermost orbital surrounding the nucleus constantly dives into the nucleus and thus samples the fields that exist inside. This sampling of the nucleus usually results in only minute shifts in the electron' s average orbital, which would be difficult to detect. By studying two particular energy states of the electron, we can, however, dramatically enhance the effects of the distribution of the magnetic fields in the nucleus. In fact about 2% of the energy difference between the two states, dubbed the hyperfine splitting, is determined by the effects related to the distribution of magnetic fields in the nucleus, A precise measurement of this energy difference (better than 0.01%) would then allow us to

  5. Experimentally Induced Pulpal Lesion and Substance P Expression: Effect of Ketoprofen—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Gian Marco Abbate

    2016-01-01

    Full Text Available Objectives. To evaluate substance P (SP and the effect of ketoprofen administration, a nonsteroidal anti-inflammatory drug (NSAID, on SP in the pulp of upper third molars with experimentally induced pulpal lesion. Materials and Methods. A sample of 20 young systemically healthy adults of both sexes, nonsmokers, with a healthy upper third molar to extract for orthodontic purposes, was selected. Prior to the procedure, an inflammatory process was generated by mechanical exposure of the pulp. After 15 minutes, the pulp was collected using a sterile barbed broach. SP levels were determined by using a commercially available enzyme immunoassay (ELISA kit. The subjects were randomly divided into two groups: group 1 received a dose of ketoprofen 30 minutes prior to the experimental procedure. The subjects of group 2 did not receive any kind of drug administration. The patients were asked to complete a diary on the postoperative pain. Results. No statistically significant difference could be detected in SP expression between the two groups. In group 1, pain manifestation was significantly delayed in comparison with group 2. Conclusions. Preventive administration of ketoprofen did not significantly affect the pulpal levels of SP but resulted in a significantly postponed manifestation of pain after extraction.

  6. Bridging the gap: Research and validation of the DST (Dynamic System Testing) performance test method for CE and ISO standards. Progress and preliminary results

    NARCIS (Netherlands)

    Naron, D.J.; Ree, B.G.C. van der; Rolloos, M.

    1998-01-01

    The Dynamic System Testing (DST) method is one of the methods chosen in the preliminary CEN/TC 312 European quality standards [1 ] to measure the energetic performance of Solar Domestic Hot Water (SDHW) systems. These European standards make a reference to the DST procedure as defined in the Draft I

  7. Hyperacuity test to evaluate vision through dense cataracts: research preliminary to a clinical study in India

    Science.gov (United States)

    Enoch, Jay M.; Giraldez, Maria J.; Huang, Doahua; Hirose, Hiroshi; Knowles, Richard A.; Namperumalsamy, P.; LaBree, Lauri; Azen, Stanley P.

    1995-03-01

    Using high luminance point-of-light stimuli, Vernier judgments can be made in the presence of markedly degraded retinal imagery. Without coaching, observers perform center-of-gravity assessments of relative locations of degraded point images. We seek to defined, presurgery, individuals who will derive the most benefit from advanced cataract removal (a form of triage), and to determine which of two cataractous eyes has the better postsurgical visual prognosis. There are incredible and growing backlogs of patients with severe cataracts (and other dense media opacities) in the developing world, and generally, limited resources are available for provision of health care. Postcataract surgical failure rates for good visual function are often high, and only one eye is operated on in over 95% of indigent patients treated. Prior to initiating advanced studies in the developing world, at Berkeley we conducted preliminary research on Vernier acuity test techniques on normal adult subjects. We sought to determine the number of repeat trials necessary; to compare a two-point and a three-point Vernier display; to determine the shape of the measured response function at large gap separations between test points (required when testing advanced cataract patients); to assess the effect(s) of a broad range of uncorrected refractive errors on outcomes; and to consider means to minimize refraction-based errors. From these and prior data and analyses, we defined a protocol for use in the developing world. Using a newly designed and rugged precision instrument, these tests were repeated on an advanced cataract population at Aravind Eye Hospital in Madurai, India. Although we had much prior experience in India, the initial protocol required major revision on site. Necessary changes in test methods and analytical approaches were made, and next stages in this program were planned. And a new and simple gap `visual acuity' (gap `VA') test was added to the protocol, which greatly facilitated

  8. Preliminary Flight Results of the Microelectronics and Photonics Test Bed: NASA DR1773 Fiber Optic Data Bus Experiment

    Science.gov (United States)

    Jackson, George L.; LaBel, Kenneth A.; Marshall, Cheryl; Barth, Janet; Seidleck, Christina; Marshall, Paul

    1998-01-01

    NASA Goddard Spare Flight Center's (GSFC) Dual Rate 1773 (DR1773) Experiment on the Microelectronic and Photonic Test Bed (MPTB) has provided valuable information on the performance of the AS 1773 fiber optic data bus in the space radiation environment. Correlation of preliminary experiment data to ground based radiation test results show the AS 1773 bus is employable in future spacecraft applications requiring radiation tolerant communication links.

  9. Experimentally Testing the Mulitverse/Many-Worlds Theory

    Science.gov (United States)

    Tipler, Frank

    2014-06-01

    Many-Worlds quantum mechanics is NOT experimentally equivalent to standard quantum mechanics. I shall demonstrate this fact and investigate its consequences. I first show the Schrödinger equation is a special case of the classical Hamilton-Jacobi equation, with |Ψ|2 being most naturally interpreted as a quantity proportional to the density of universes in the multiverse. I then show that with this interpretation for |Ψ|2, we can test the multiverse theory, because in the multiverse theory, the Born Interpretation is derived from this assumption, not merely assumed as in standard quantum theory, and the derivation gives us a means of computing how fast |Ψ|2 will build up from individual particles in an experiment, a computation I shall show cannot be done in standard quantum mechanics. In some types of experiments, the observed pattern will approach the final Born pattern as 1/N1/2, and in other types of experiments, the approach will be as 1/N, where N is the number of observed “particles.” The multiverse meaning of has other advantages over the standard probability amplitude meaning, because if is a universe density amplitude, need not be restricted to being a Hilbert space function. In particular, delta functions and plane waves are NOT functions in any Hilbert space, but they are both used extensively in quantum mechanics, though disallowed by the axioms of standard quantum mechanics. Finally, I shall show that multiverse experiments have important implications for cosmology. The Wheeler-DeWitt equation for quantum gravity, applied to a spatially closed Friedman radiation universe in conformal time, is mathematically the Schrödinger equation for a simple harmonic oscillator. I show that if the wave function of the universe were a delta function at the initial singularity — I show that the universes being exactly classical now implies such a universal wave function — then we are overwhelmingly likely to find ourselves in a closed universe that is

  10. Experimental Test for epsilon-Expansions with n=4

    DEFF Research Database (Denmark)

    Ott, H. R.; Kjems, Jørgen

    1980-01-01

    epsilon (Porson)-expansion calculations predict the magnetic phase transitions of the Ce monochalcogenides to be first order. We present experimental evidence that the transitions in CeSe and CeTe are continuous.......epsilon (Porson)-expansion calculations predict the magnetic phase transitions of the Ce monochalcogenides to be first order. We present experimental evidence that the transitions in CeSe and CeTe are continuous....

  11. A smartphone-based platform to test the performance of wireless mobile networks and preliminary findings

    Science.gov (United States)

    Geng, Xinli; Xu, Hao; Qin, Xiaowei

    2016-10-01

    During the last several years, the amount of wireless network traffic data increased fast and relative technologies evolved rapidly. In order to improve the performance and Quality of Experience (QoE) of wireless network services, the analysis of field network data and existing delivery mechanisms comes to be a promising research topic. In order to achieve this goal, a smartphone based platform named Monitor and Diagnosis of Mobile Applications (MDMA) was developed to collect field data. Based on this tool, the web browsing service of High Speed Downlink Packet Access (HSDPA) network was tested. The top 200 popular websites in China were selected and loaded on smartphone for thousands times automatically. Communication packets between the smartphone and the cell station were captured for various scenarios (e.g. residential area, urban roads, bus station etc.) in the selected city. A cross-layer database was constructed to support the off-line analysis. Based on the results of client-side experiments and analysis, the usability of proposed portable tool was verified. The preliminary findings and results for existing web browsing service were also presented.

  12. Augmented Reality Cubes for Cognitive Gaming: Preliminary Usability and Game Experience Testing

    Directory of Open Access Journals (Sweden)

    Costas Boletsis

    2016-03-01

    Full Text Available Early detection is important in dementia care; however, cognitive impairment is still under-recognised and under-diagnosed. Cognitive screening and training are two important preventative treatments, which can lead to early detection of cognitive decline. In this work, the “Cognitive Augmented Reality Cubes” (CogARC system is presented, i.e. a serious game for cognitive training and screening, utilising an interaction technique based on Augmented Reality and the manipulation of tangible, physical objects (cubes. The game is a collection of cognitive mini-games of preventative nature and is, primarily, targeting elderly players (≥60 years old. A preliminary testing was conducted focusing on the game experience that CogARC offers (utilising the In-Game Experience Questionnaire, the usability of the system (using the System Usability Scale, and the specific user observations and remarks, as documented by open, semi-structured interviews.  Overall, CogARC demonstrated satisfying positive responses, however, the negative reactions indicated that there are specific problems with aspects of the interaction technique and a number of mini-games. The open interview shed more light on the specific issues of each mini-game and further interpretation of user interactions. The current study managed to provide interesting insights into the game design elements, integration of Augmented Reality, tangible interaction of the system, and on how elderly players perceive and use those interaction components. 

  13. Soda-Anthraquinone Durian (Durio Zibethinus Murr.) Rind Linerboard and Corrugated Medium Paper: A Preliminary Test

    Science.gov (United States)

    Rizal Masrol, Shaiful; Irwan Ibrahim, Mohd Halim; Adnan, Sharmiza; Mubarak Sa'adon, Amir; Ika Sukarno, Khairil; Fadrol Hisham Yusoff, Mohd

    2017-08-01

    A preliminary test was conducted to investigate the characteristics of linerboard and corrugated medium paper made from durian rind waste. Naturally dried durian rinds were pulped according to Soda-Anthraquinone (Soda-AQ) pulping process with a condition of 20% active alkali, 0.1% AQ, 7:1 liquor to material ratio, 120 minutes cooking time and 170°C cooking temperature. The linerboard and corrugated medium paper with a basis weight of 120 gsm were prepared and evaluated according to Malaysian International Organization for Standardization (MS ISO) and Technical Association of the Pulp and Paper Industry (TAPPI). The results indicate that the characteristics of durian rind linerboard are comparable with other wood or non-wood based paper and current commercial paper. However, low CMT value for corrugated medium and water absorptiveness quality for linerboard could be improved in future. Based on the bulk density (0.672 g/cm3), burst index (3.12 kPa.m2/g) and RCT (2.00 N.m2/g), the durian rind has shown a good potential and suitable as an alternative raw material source for linerboard industry.

  14. Preliminary Tests of Cellular SiC/Iron Alloy Composite Produced by a Pressureless Infiltration Technique

    Directory of Open Access Journals (Sweden)

    Lipowska B.

    2017-03-01

    Full Text Available Preliminary tests aimed at obtaining a cellular SiC/iron alloy composite with a spatial structure of mutually intersecting skeletons, using a porous ceramic preform have been conducted. The possibility of obtaining such a composite joint using a SiC material with an oxynitride bonding and grey cast iron with flake graphite has been confirmed. Porous ceramic preforms were made by pouring the gelling ceramic suspension over a foamed polymer base which was next fired. The obtained samples of materials were subjected to macroscopic and microscopic observations as well as investigations into the chemical composition in microareas. It was found that the minimum width of a channel in the preform, which in the case of pressureless infiltration enables molten cast iron penetration, ranges from 0.10 to 0.17 mm. It was also found that the ceramic material applied was characterized by good metal wettability. The ceramics/metal contact area always has a transition zone (when the channel width is big enough, where mixing of the components of both composite elements takes place.

  15. Gold Nanoparticles as Probes for Nano-Raman Spectroscopy: Preliminary Experimental Results and Modeling

    Directory of Open Access Journals (Sweden)

    V. Le Nader

    2012-01-01

    Full Text Available This paper presents an effective Tip-Enhanced Raman Spectrometer (TERS in backscattering reflection configuration. It combines a tip-probe nanopositioning system with Raman spectroscope. Specific tips were processed by anchoring gold nanoparticles on the apex of tapered optical fibers, prepared by an improved chemical etching method. Hence, it is possible to expose a very small area of the sample (~20 nm2 to the very strong local electromagnetic field generated by the lightning rod effect. This experimental configuration was modelled and optimised using the finite element method, which takes into account electromagnetic effects as well as the plasmon resonance. Finally, TERS measurements on single-wall carbon nanotubes were successfully performed. These results confirm the high Raman scattering enhancement predicted by the modelling, induced by our new nano-Raman device.

  16. Preliminary Experimental Results of Deep Levels for Dielectronic Recombination in He-Like High-Z Ions at Heidelberg Electron Beam Ion Trap

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xue-Mei(张雪梅); GUO Pan-Lin(郭盘林); A.Gonzalez; J.CRESPO

    2003-01-01

    An experimental system for dielectronic recombination was set-up on H-EBIT in order to carry out dielectronic recombination study. Some preliminary results of He-like Ge32+ and Cu27+ are obtained. Space charge shift on determination of the resonance position for Ge32+ at 100mA is around 18% and that for Cu27+ is around 38%.Further analysis of experimental data is in progress.

  17. Preliminary experimental research on friction characteristics of a thick gravitational casted babbit layer on steel substrate

    Science.gov (United States)

    Paleu, V.; Georgescu, S.; Baciu, C.; Istrate, B.; Baciu, E. R.

    2016-08-01

    The ability of the antifriction materials to withstand with no lubrication for a while can be a solution for the catastrophic failure of automotive journal bearings from the internal combustion engines in accidental breakdown of the oil pump. A thick layer of antifriction material (babbit) was deposited by gravitational casting on a steel disk substrate. Four tribological disk samples coated with babbit are tested against a steel shoe on Amsler tribometer at different speeds and loads in dry friction. The values of the friction coefficient versus speed and load are presented, the obtained results indicating a mild wear regime, recommending the new babbit as a possible coating for the bushes of the journal bearings in automotive internal combustion engines. Further tests must be dedicated to the establishment of the wear intensity of the steel shoe - babbit disk tribological pair, both for motor oil lubricated and dry friction conditions.

  18. Shape Effect of Crushed Sand Filler on Rheology: A Preliminary Experimental and Numerical Study

    DEFF Research Database (Denmark)

    Spangenberg, Jon; Cepuritis, Rolands; Hovad, Emil

    2016-01-01

    was quantified with the slump flow test (i.e. mini cone). The shape effect was isolated in the experiments by the use of non overlapping bimodal particle distributions of cement particles with a number average diameter of approximate to 0.01 mm and filler particles with a number average diameter of approximate...... classification, and had length/thickness (L/T) aspect ratios of 2.00 and 1.82, respectively. The particles were characterized with X-ray micro-computed tomography, coupled with spherical harmonic analysis to mathematically describe the full 3-D shape of the particles, while the rheological performance...... to 0.1 mm. The two filler types were tested with a range of chi-values (volume of cement divided by total volume of solids). The flowability of the matrix increased with decreasing aspect ratios of the filler. However, the chi-value at which the maximum volume fraction threshold was obtained varied...

  19. Preliminary Beam Tests at REX for an Automatic Cavity Phasing Routine at HIE-ISOLDE

    CERN Document Server

    Fraser, M A; Broere, J; Lanaia, D; Valuch, D

    2013-01-01

    The HIE upgrade at ISOLDE will use 32 independently phased superconducting quarterwave cavities, which will impose new demands on the operation and set-up of the linac. The large range of different radioactive species and the broad experimental programme means that the same beam species and energy are rarely studied twice, and the accelerator must be re-tuned for each experimental run. In order to expedite machine set-up it is foreseen to calculate and set automatically the cavity phases when the operator inputs the desired beam energy and A/q of the beam species. In this note we explore our understanding of the REX rf system and test our beam dynamics calculations with two independently phased 7-gap split-ring cavities.

  20. Preliminary experimental results of radiofrequency-cement-augmented and cannulated pedicle screws

    Directory of Open Access Journals (Sweden)

    Goost H

    2011-01-01

    Full Text Available The risk of cut-out of a pedicle screw is high in the presence of osteoporotic bone. In cadaver studies it was found that cement augmentation of pedicle screws markedly increases pullout forces. However, the use of conventional low viscosity vertebroplasty or kyphoplasty cement is associated with the risk of cement extravasation. The risk might be reduced by using high viscosity, radiofrequency-activated bone cement. After performing DEXA scans, six fresh-frozen vertebral bodies of different bone densities were obtained from cadavers. Two pedicle screws (WSI Expertise-Inject, Peter Brehm, Germany were placed in the pedicles. About 3 ml of radiofrequency-activated, ultra-high viscosity cement (ER2 Bone Cement, DFine Europe GmbH, Germany was injected through the right pedicle. The left pedicle screw was left uncemented and served as control. Axial pullout tests were performed using a material testing device (Zwick/Roell Zmartpro, Ulm, Germany. The tests revealed that cementaugmented pedicle screws were able to withstand markedly higher pullout forces. Extravasation of cement did not occur. The value of the study is limited by the fact that only six samples were investigated. Further cadaver studies and clinical evaluation will be needed in the future. However, this pilot study showed that combining cannulated pedicle screws with ultra-high viscosity bone cement is a successful approach. Revision due to cut-out and complications secondary to cement extravasation can be reduced by this method.

  1. Experimental test plan: USDOE/JAERI collaborative program for the coated particle fuel performance test

    Energy Technology Data Exchange (ETDEWEB)

    Kania, M.J. [Oak Ridge National Lab., TN (United States); Fukuda, K. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1989-12-01

    This document describes the coated-particle fuel performance test agreed to under Annex 2 of the arrangement between the US Department of Energy and the Japan Atomic Energy Research Institute on cooperation in research and development regarding high-temperature gas-cooled reactors (HTGRs). The test will evaluate the behavior of reference fuel compacts containing coated-particle fuels fabricated according to the specifications for the US Modular HTGR and the Japanese High-Temperature Engineering Test Reactor (HTTR) concepts. Two experimental capsules, HRB-21 and HRB-22, are being tested. Capsule HRB-21 contains only US reference fuel, and HRB-22 contains only JAERI reference fuel. Both capsules will be irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). Capsule HRB-21 will be operated at a mean volumetric fuel temperature of 975{degrees}C and will achieve a peak fissile burnup of 26% fissions per initial metal atom (FIMA) and a fast fluence of {le}4.5 {times} 10{sup 25} neutrons/m{sup 2}. Capsule HRB-22 will be operated at a mean centerline fuel temperature of 1250 to 1300{degrees}C and will achieve a peak fissile burnup of 5.5% FIMA and a fast fluence of 1.7 {times} 10{sup 25} neutrons/m{sup 2}. Performance of the fuels during irradiation will be closely monitored using on-line fission gas surveillance. Following irradiation, both capsules will undergo detailed examinations and core heatup simulation testing. Results from in-reactor monitoring and postirradiation testing will be analyzed to comparatively assess US and Japanese coated-particle fuel performance. 3 refs., 9 figs., 10 tabs.

  2. Experimental Study on Excavation Characteristics of Rockmass by Triaxial Test

    Institute of Scientific and Technical Information of China (English)

    谢红强; 姚勇; 何川; 杨庆

    2004-01-01

    Applying MTS rock stiffness test machine, tests under triaxial condition were carried out for rockmass under loading and unloading. By measuring and analyzing such mechanical properties as stress, strain, elastic modulus, Poisson ratio and elastic wave velocity during the whole test process, the differences of mechanical characteristics under loading and unloading conditions were revealed, to provide some useful references for excavation.

  3. Patient empowerment in long-term conditions: development and preliminary testing of a new measure.

    Science.gov (United States)

    Small, Nicola; Bower, Peter; Chew-Graham, Carolyn A; Whalley, Diane; Protheroe, Joanne

    2013-07-08

    Patient empowerment is viewed by policy makers and health care practitioners as a mechanism to help patients with long-term conditions better manage their health and achieve better outcomes. However, assessing the role of empowerment is dependent on effective measures of empowerment. Although many measures of empowerment exist, no measure has been developed specifically for patients with long-term conditions in the primary care setting. This study presents preliminary data on the development and validation of such a measure. We conducted two empirical studies. Study one was an interview study to understand empowerment from the perspective of patients living with long-term conditions. Qualitative analysis identified dimensions of empowerment, and the qualitative data were used to generate items relating to these dimensions. Study two was a cross-sectional postal study involving patients with different types of long-term conditions recruited from general practices. The survey was conducted to test and validate our new measure of empowerment. Factor analysis and regression were performed to test scale structure, internal consistency and construct validity. Sixteen predominately elderly patients with different types of long-term conditions described empowerment in terms of 5 dimensions (identity, knowledge and understanding, personal control, personal decision-making, and enabling other patients). One hundred and ninety seven survey responses were received from mainly older white females, with relatively low levels of formal education, with the majority retired from paid work. Almost half of the sample reported cardiovascular, joint or diabetes long-term conditions. Factor analysis identified a three factor solution (positive attitude and sense of control, knowledge and confidence in decision making and enabling others), although the structure lacked clarity. A total empowerment score across all items showed acceptable levels of internal consistency and relationships

  4. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, T. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Mueller-Schauenburg, W. [Abt. Nuklearmedizin, Univ. Tuebingen (Germany); Goeke, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Luebeck, M. [Abt. Nuklearmedizin, Univ.-Krankenhaus Eppendorf, Hamburg (Germany); Gratz, K.F. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Meier, P. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Manns, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Hundeshagen, H. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany)

    1995-11-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  5. Development and verification test of integral reactor major components - Development of MCP impeller design, performance prediction code and experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Kyoon; Oh, Woo Hyoung; Song, Jae Wook [Korea Advanced Institute of Science and Technology, Taejon (Korea)

    1999-03-01

    The present study is aimed at developing a computational code for design and performance prediction of an axial-flow pump. The proposed performance prediction method is tested against a model axial-flow pump streamline curvature method. The preliminary design is made by using the ideal velocity triangles at inlet and exit and the three dimensional blade shape is calculated by employing the free vortex design method. Then the detailed blading design is carried out by using experimental database of double circular arc cambered hydrofoils. To computationally determine the design incidence, deviation, blade camber, solidity and stagger angle, a number of correlation equations are developed form the experimental database and a theorical formula for the lift coefficient is adopted. A total of 8 equations are solved iteratively using an under-relaxation factor. An experimental measurement is conducted under a non-cavitating condition to obtain the off-design performance curve and also a cavitation test is carried out by reducing the suction pressure. The experimental results are very satisfactorily compared with the predictions by the streamline curvature method. 28 refs., 26 figs., 11 tabs. (Author)

  6. Experimental Investigations of Ice Rubble: Shear Box and Pile Testing

    OpenAIRE

    Astrup, Oda Skog

    2012-01-01

    The largest part of an ice ridge consists of unconsolidated ice rubble, whose material properties decide the load from ridges on ships and structures. Material resistance is attributed to the initial freeze-bonds and the friction and interlocking between blocks. The objective of the thesis was to investigate rubble behaviour by two tests: shear box test at NTNU and pile test at HSVA. The shear box test was aimed at investigating freeze-bond mechanisms in rubble. The pile test was aimed at sug...

  7. Joint tests for quantitative trait loci in experimental crosses

    Science.gov (United States)

    Beasley, T Mark; Yang, Dongyan; Yi, Nengjun; Bullard, Daniel C; Travis, Elizabeth L; Amos, Christopher I; Xu, Shizhong; Allison, David B

    2004-01-01

    Selective genotyping is common because it can increase the expected correlation between QTL genotype and phenotype and thus increase the statistical power of linkage tests (i.e., regression-based tests). Linkage can also be tested by assessing whether the marginal genotypic distribution conforms to its expectation, a marginal-based test. We developed a class of joint tests that, by constraining intercepts in regression-based analyses, capitalize on the information available in both regression-based and marginal-based tests. We simulated data corresponding to the null hypothesis of no QTL effect and the alternative of some QTL effect at the locus for a backcross and an F2 intercross between inbred strains. Regression-based and marginal-based tests were compared to corresponding joint tests. We studied the effects of random sampling, selective sampling from a single tail of the phenotypic distribution, and selective sampling from both tails of the phenotypic distribution. Joint tests were nearly as powerful as all competing alternatives for random sampling and two-tailed selection under both backcross and F2 intercross situations. Joint tests were generally more powerful for one-tailed selection under both backcross and F2 intercross situations. However, joint tests cannot be recommended for one-tailed selective genotyping if segregation distortion is suspected. PMID:15496283

  8. Mobile Software Testing: Thoughts, Strategies, Challenges, and Experimental Study

    Directory of Open Access Journals (Sweden)

    Mohammed Akour

    2016-06-01

    Full Text Available Mobile devices have become more pervasive in our daily lives, and are gradually replacing regular computers to perform traditional processes like Internet browsing, editing photos, playing videos and sound track, and reading different files. The importance of mobile devices in our life necessitates more concerns of the reliability and compatibility of mobile applications, and thus, testing these applications arises as an important phase in mobile devices adaption process. This paper addressed various research directions on mobile applications testing by investigating essential concepts, scope, features and requirements for testing mobile application. We highlight the similarities and the differences between mobile APP testing and mobile web testing. Furthermore, we discuss and compare different mobile testing approaches and environments, and provide the challenges as emergent needs in test environments. As a case study, we compared the testing experience of hybrid application in an emulator and a real world device. The purpose of the experiment is to verify to which extent a virtual device can emulate a complete client experience. Set of experiments are conducted where five android mobile browsers are tested. Each browser will be on a real device as well as an emulated device with the same features (CPU used, memory size, etc. The application will be tested on the following metrics: Performance and function/behavior testing.

  9. Performance characteristics of DRI, CEDIA, and REMEDi systems for preliminary tests of amphetamines and opiates in human urine.

    Science.gov (United States)

    Huang, Min-Kun; Dai, Yu-Shan; Lee, Choung-Huei; Liu, Chiareiy; Tsay, Wen-Ing; Li, Jih-Heng

    2006-01-01

    Arrestee urine specimens (930) were tested with DRI, CEDIA, and REMEDi; those that tested positive for amphetamines and opiates (616 and 414, respectively) were then confirmed by gas chromatography-mass spectrometry. The performance characteristics of these three preliminary systems were evaluated using the following commonly used parameters: true positive, true negative, false positive, and false negative. The sensitivity, specificity, and efficiency of these methods were also calculated. Data derived from this study indicated DRI and CEDIA adapted by this study generated acceptable preliminary test results for amphetamine/methamphetamine and morphine/codeine, but not for MDA/MDMA and REMEDi has lower sensitivity than DRI and CEDIA, but with better specificity and efficiency, supporting its use under emergency room settings where drug concentrations in overdose cases are expectedly at high levels.

  10. Experimental testing of a SAG digital SILT application

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, P.; Maskuniitty, M.; Heikkinen, J.; Korhonen, J.

    1995-10-01

    A prototype dynamic testing harness for programmable automation systems has been specified and implemented at the Technical Research Centre of Finland (VTT). In order to get experience on the methodology and equipment for the testing of systems important to the safety of nuclear power plants, where the safety and reliability requirements often are very high, two different pilot systems have been tested. One system was an ABB Master application, which was loaned for testing from ABB Atom by Teollisuuden Voima Oy (TVO). Another system, loaned from Siemens AG(SAG) by IVO International Oy (IVO), was an application realized with SAG`s digital SILT technology. The report describes the testing of the SAG application. The purpose of the testing was not to assess the pilot system, but to get experience in the testing methodology and find out the further development needs and potentials of the test methodology and equipment. The experience show that dynamic testing is one feasible way to get more confidence about the safety and reliability of a programmable system that would be hard to achieve by other means. It also shows that more development of the test harness is still needed, especially concerning the comparison of the obtained test response to the expected response provided by the logical model of the system. Also the user interface of the on-line part of the test harness needs development. Methods for generation of the test cases also need further development eg. for achieving statistical significance for the reliability estimates. (10 refs., 90 figs., 9 tabs.).

  11. Zernike test. I - Analytical aspects. II - Experimental aspects. [interferometric phase error test

    Science.gov (United States)

    Golden, L. J.

    1977-01-01

    The Zernike phenomenon is interpreted in general interferometric terms to gain insight into the optimum design of disks suitable for a particular experimental situation. The design of Zernike disks for measuring small low-order aberrations is considered and evaluated; optimum parameters for disks 2, 3, 4, and 5 microns in radius are determined for an f/12 large-space-telescope system with an obscuration ratio of 0.4 at 0.6 micron. It is shown that optimization in this case provides sensitivities of better than one hundredth of a wavelength for the measurement of low-order aberrations. The procedure for manufacturing a Zernike disk is then described in detail, and results are reported for tests of a laboratory Zernike figure sensor containing a disk manufactured according to this procedure. In the tests, a laboratory wavefront-error simulator was used to introduce small aberration ranges, measurements of the changes in reimaged pupil intensity introduced by the disk were made for several aberration settings, and the measured changes were compared with the values predicted by the interferometric theory of Zernike tests. The results are found to agree within an error of one two-hundredth of a wavelength.

  12. Experimental Test of the Spin Mixing Interface Conductivity Concept

    NARCIS (Netherlands)

    Weiler, M.; Althammer, M.; Schreier, M.; Lotze, J.; Pernpeintner, M.; Meyer, S.; Huebl, H.; Gross, R.; Kamra, A.; Xiao, J.; Chen, Y.T.; Jiao, H.J.; Bauer, G.E.W.; Goennenwein, S.T.B.

    2013-01-01

    We perform a quantitative, comparative study of the spin pumping, spin Seebeck, and spin Hall magnetoresistance effects, all detected via the inverse spin Hall effect in a series of over 20  yttrium   iron garnet/Pt samples. Our experimental results fully support present, exclusively spin current-ba

  13. The quark gluon plasma: Lattice computations put to experimental test

    Indian Academy of Sciences (India)

    Sourendu Gupta

    2003-11-01

    I describe how lattice computations are being used to extract experimentally relevant features of the quark gluon plasma. I deal specifically with relaxation times, photon emissivity, strangeness yields, event-by-event fluctuations of conserved quantities and hydrodynamic flow. Finally I give evidence that the plasma is rather liquid-like in some ways.

  14. Simulations for the Test Flight of an Experimental HALE Aircraft

    Science.gov (United States)

    2011-06-01

    NASA Stress Analysis Program NPRF Navy Pacific Range Facility ONERA Office National d’Etudes et Recherches Aérospatiales SBC Single Board Computer...Dowell [34] experimentally validated an ONERA unsteady aerodynamic model using nonlinear structural modeling. Their results also validated their

  15. Engineering Tests of Experimental Ammonia Process Printer-Developer

    Science.gov (United States)

    1950-07-06

    up for an experimental am:tmoa process printer- developer to meet the military characteristics. Thlis machine was Krocurod under development contract ...over the top of the can. A small light on the front panel of the mucl -ine indicates when the level of the ammonia in the storage tank is such that

  16. Pyrolysis process for the treatment of scrap tyres: preliminary experimental results.

    Science.gov (United States)

    Galvagno, S; Casu, S; Casabianca, T; Calabrese, A; Cornacchia, G

    2002-01-01

    The aim of this work is the evaluation, on a pilot scale, of scrap tyre pyrolysis process performance and the characteristics of the products under different process parameters, such as temperature, residence time, pressure, etc. In this frame, a series of tests were carried out at varying process temperatures between 550 and 680 degrees C, other parameters being equal. Pyrolysis plant process data are collected by an acquisition system; scrap tyre samples used for the treatment, solid and liquid by-products and produced syngas were analysed through both on-line monitoring (for gas) and laboratory analyses. Results show that process temperature, in the explored range, does not seem to seriously influence the volatilisation reaction yield, at least from a quantitative point of view, while it observably influences the distribution of the volatile fraction (liquid and gas) and by-products characteristics.

  17. Experimental oral toxicity of domoic acid in cynomolgus monkeys (Macaca fascicularis) and rats. Preliminary investigations.

    Science.gov (United States)

    Tryphonas, L; Truelove, J; Todd, E; Nera, E; Iverson, F

    1990-10-01

    A recent outbreak of marine food poisoning in humans was attributed to the consumption of blue mussels (Mytilus edulis L.) contaminated with domoic acid (DA) that was produced by the diatom Nitzschia pungens. The clinical and morphological effects of single oral doses of extracts of mussels contaminated with DA or of DA isolated from toxic mussels were investigated in small groups (one to six) of cynomolgus monkeys (Macaca fascicularis; 0.5-10 mg DA/kg body weight) and of Sprague-Dawley rats (60 to 80 mg DA/kg body weight). Control animals were either given saline or were not treated. To test whether monosodium glutamate, present in the food consumed by some affected humans, and dimethylsulphoxide, suspected of being present in the plankton, enhanced the response, monosodium glutamate (at 0.25% of mussel extract bolus) or dimethylsulphoxide (at 1 g per bolus) were co-administered to two (one each) of the DA-treated monkeys. DA-treated monkeys developed transient excitation characterized by vomiting. DA-treated rats showed withdrawal followed by hyperexcitation and death (in one case). Mild to moderate central nervous system lesions consistent with neuroexcitation were present in both monkeys and rats. The addition of monosodium glutamate and dimethylsulphoxide had no significant effect on the appearance and severity of central nervous system clinical signs and lesions. The wide variations in the response of test animals to orally administered DA were attributed to the protective effect of vomiting, and to suspected incomplete or slow gastro-intestinal absorption of the toxic agent. The results reinforce the view that DA is an emetic and that under appropriate conditions may also inflict excitotoxic central nervous system damage.

  18. Preliminary aquatic risk assessment of imidacloprid after application in an experimental rice plot.

    Science.gov (United States)

    Daam, Michiel A; Santos Pereira, Ana C; Silva, Emília; Caetano, Lia; Cerejeira, Maria José

    2013-11-01

    The potential aquatic risk of application of the neonicotinoid insecticide imidacloprid for aphid control in rice was assessed. To this end, imidacloprid was applied as Confidor(®) 200 SC at the recommended field dose of 100g a.i./ha to a Portuguese rice plot. Subsequently, fate of the test compound in water and potential effects of water samples on a battery of test species were determined. As compared to the first-tier predicted environmental concentrations (PECs) calculated using MED-Rice (around 30µg/L depending on the scenario used) and US-EPA (78µg/L) simulations, the actual peak concentration measured in the paddy water (52µg/L) was higher and lower, respectively. As was anticipated based on 50% effect concentrations (EC50 values) for Daphnia magna published in the open literature and that calculated in the present study (48h-EC50 immobility=84mg/L), no effects were observed of field water samples on daphnids. The sediment-dwelling ostracod Heterocypris incongruens, however, appeared relatively sensitive towards imidacloprid (6d-EC50 growth inhibition=0.01-0.015mg/L) and a slight effect was indeed noted in field samples taken the first week after application. Species sensitivity distributions based on published EC50 and NOEC values also revealed that other species are likely to be affected at the peak and time-weighted average imidacloprid concentrations, respectively. By applying the relative tolerance approach (i.e. by dividing the EC50 value of a certain species with that of Daphnia magna), ostracods appear to contain the most sensitive taxa to imidacloprid, followed by EPT (Ephemeroptera, Plecoptera and Trichoptera) taxa. Future field studies into (higher-tier) fate modelling of pesticides in rice paddies and effect assessment on field communities are required to ensure protection of aquatic life and wildlife (e.g. birds) from pesticide stress.

  19. A preliminary neutronic evaluation of high temperature engineering test reactor using the SCALE6 code

    Science.gov (United States)

    Tanure, L. P. A. R.; Sousa, R. V.; Costa, D. F.; Cardoso, F.; Veloso, M. A. F.; Pereira, C.

    2014-02-01

    Neutronic parameters of some fourth generation nuclear reactors have been investigated at the Departamento de Engenharia Nuclear/UFMG. Previous studies show the possibility to increase the transmutation capabilities of these fourth generation systems to achieve significant reduction concerning transuranic elements in spent fuel. To validate the studies, a benchmark on core physics analysis, related to initial testing of the High Temperature Engineering Test Reactor and provided by International Atomic Energy Agency (IAEA) was simulated using the Standardized Computer Analysis for Licensing Evaluation (SCALE). The CSAS6/KENO-VI control sequence and the 44-group ENDF/B-V 0 cross-section neutron library were used to evaluate the keff (effective multiplication factor) and the result presents good agreement with experimental value.

  20. Experimental Applications of Automatic Test Markup Language (ATML)

    Science.gov (United States)

    Lansdowne, Chatwin A.; McCartney, Patrick; Gorringe, Chris

    2012-01-01

    The authors describe challenging use-cases for Automatic Test Markup Language (ATML), and evaluate solutions. The first case uses ATML Test Results to deliver active features to support test procedure development and test flow, and bridging mixed software development environments. The second case examines adding attributes to Systems Modelling Language (SysML) to create a linkage for deriving information from a model to fill in an ATML document set. Both cases are outside the original concept of operations for ATML but are typical when integrating large heterogeneous systems with modular contributions from multiple disciplines.

  1. Preliminary Experimental Examination Of Controls On Methane Expulsion During Melting Of Natural Gas Hydrate Systems

    Science.gov (United States)

    Kneafsey, T. J.; Flemings, P. B.; Bryant, S. L.; You, K.; Polito, P. J.

    2013-12-01

    Global climate change will cause warming of the oceans and land. This will affect the occurrence, behavior, and location of subseafloor and subterranean methane hydrate deposits. We suggest that in many natural systems local salinity, elevated by hydrate formation or freshened by hydrate dissociation, may control gas transport through the hydrate stability zone. We are performing experiments and modeling the experiments to explore this behavior for different warming scenarios. Initially, we are exploring hydrate association/dissociation in saline systems with constant water mass. We compare experiments run with saline (3.5 wt. %) water vs. distilled water in a sand mixture at an initial water saturation of ~0.5. We increase the pore fluid (methane) pressure to 1050 psig. We then stepwise cool the sample into the hydrate stability field (~3 degrees C), allowing methane gas to enter as hydrate forms. We measure resistivity and the mass of methane consumed. We are currently running these experiments and we predict our results from equilibrium thermodynamics. In the fresh water case, the modeled final hydrate saturation is 63% and all water is consumed. In the saline case, the modeled final hydrate saturation is 47%, the salinity is 12.4 wt. %, and final water saturation is 13%. The fresh water system is water-limited: all the water is converted to hydrate. In the saline system, pore water salinity is elevated and salt is excluded from the hydrate structure during hydrate formation until the salinity drives the system to three phase equilibrium (liquid, gas, hydrate) and no further hydrate forms. In our laboratory we can impose temperature gradients within the column, and we will use this to investigate equilibrium conditions in large samples subjected to temperature gradients and changing temperature. In these tests, we will quantify the hydrate saturation and salinity over our meter-long sample using spatially distributed temperature sensors, spatially distributed

  2. 78 FR 51678 - Market Tests of Experimental Postal Products

    Science.gov (United States)

    2013-08-21

    ... the label that includes a tracking number and a QR code. Id. This enables the mailer to check the... the QR code with a mobile device. Id. The market test began on December 10, 2011 with 50 test... amend chapter III of title 39 of the Code of Federal Regulations as follows: PART 3001--RULES...

  3. Testing Experimental Compounds against American Cutaneous and Mucocutaneous Leishmaniasis

    Science.gov (United States)

    1982-06-01

    neither of thiese imida - zoles shows promise for further development. They will not be tested further. C. Combination Chemotherapy Three types of...From 1980 - 1982, five 8-aminoquinolines, two imida - zoles, and the antimalarial primaquine phosphate were tested for efficacy as antileishmanial agents

  4. Preliminary Experimental Results of Integrated Gasification Fuel Cell Operation Using Hardware Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Traverso, Alberto; Tucker, David; Haynes, Comas L.

    2012-07-01

    A newly developed integrated gasification fuel cell (IGFC) hybrid system concept has been tested using the Hybrid Performance (Hyper) project hardware-based simulation facility at the U.S. Department of Energy, National Energy Technology Laboratory. The cathode-loop hardware facility, previously connected to the real-time fuel cell model, was integrated with a real-time model of a gasifier of solid (biomass and fossil) fuel. The fuel cells are operated at the compressor delivery pressure, and they are fueled by an updraft atmospheric gasifier, through the syngas conditioning train for tar removal and syngas compression. The system was brought to steady state; then several perturbations in open loop (variable speed) and closed loop (constant speed) were performed in order to characterize the IGFC behavior. Coupled experiments and computations have shown the feasibility of relatively fast control of the plant as well as a possible mitigation strategy to reduce the thermal stress on the fuel cells as a consequence of load variation and change in gasifier operating conditions. Results also provided an insight into the different features of variable versus constant speed operation of the gas turbine section.

  5. Subject-specific estimation of central aortic blood pressure via system identification: preliminary in-human experimental study.

    Science.gov (United States)

    Fazeli, Nima; Kim, Chang-Sei; Rashedi, Mohammad; Chappell, Alyssa; Wang, Shaohua; MacArthur, Roderick; McMurtry, M Sean; Finegan, Barry; Hahn, Jin-Oh

    2014-10-01

    This paper demonstrates preliminary in-human validity of a novel subject-specific approach to estimation of central aortic blood pressure (CABP) from peripheral circulatory waveforms. In this "Individualized Transfer Function" (ITF) approach, CABP is estimated in two steps. First, the circulatory dynamics of the cardiovascular system are determined via model-based system identification, in which an arterial tree model is characterized based on the circulatory waveform signals measured at the body's extremity locations. Second, CABP waveform is estimated by de-convolving peripheral circulatory waveforms from the arterial tree model. The validity of the ITF approach was demonstrated using experimental data collected from 13 cardiac surgery patients. Compared with the invasive peripheral blood pressure (BP) measurements, the ITF approach yielded significant reduction in errors associated with the estimation of CABP, including 1.9-2.6 mmHg (34-42 %) reduction in BP waveform errors (p < 0.05) as well as 5.8-9.1 mmHg (67-76 %) and 6.0-9.7 mmHg (78-85 %) reductions in systolic and pulse pressure (SP and PP) errors (p < 0.05). It also showed modest but significant improvement over the generalized transfer function approach, including 0.1 mmHg (2.6 %) reduction in BP waveform errors as well as 0.7 (20 %) and 5.0 mmHg (75 %) reductions in SP and PP errors (p < 0.05).

  6. Experimentally Switching from Factory Made to Self-Made Cigarettes: A Preliminary Study of Perceptions, Toxicant Exposure and Smoking Behavior.

    Science.gov (United States)

    Koszowski, Bartosz; Rosenberry, Zachary R; Strasser, Andrew A; Pickworth, Wallace B

    2014-04-01

    There is currently the potential for a great deal of transition and product switching among cigarette smokers. Studies on the transition when cigarette smokers switch from one type of nicotine delivery product to another are needed to understand subsequent toxicant exposure. A preliminary study was performed to determine the feasibility of experimentally replicating the transition from factory made (FM) to personal machine made (PMM) cigarette smoking. The adaptability and perceptions of the consumer and the consequent exposure to cigarette-delivered toxins were assessed. Six adults (4 men) were recruited for four laboratory visits (V1-V4) on study days 1, 5, 10 and 15, respectively. All of the participants agreed to switch from exclusive FM smoking to exclusive PMM cigarette smoking for the duration of the study. Compliance was very high among these participants. Participants progressively accepted the PMM cigarettes and became efficient producers of PMMs as evidenced in the reduced time to make 5 PMMs in the laboratory. Participants reported a preference for FM at visit 2 (V2), but had stated no preference by the fourth visit. Compared to the FMs, the PMMs at V3 (psmoking (for both FM and PMM) and 34.0±5.3 ng/mL after smoking; there were no significant differences in the plasma nicotine boost (average 17.7 and 15.4ng/ml after FM and PMM smoking, respectively). Although there were differences between individual subjects' filter butt levels of deposited solanesol the within-subject levels were remarkably similar. Puff topography measures did not vary across visits or cigarette type. Although interpretation of study results must be conservative because of the small sample size, this study demonstrates that experimentally-induced transition from FM to PMM smoking is feasible for laboratory study and the subsequent toxicant exposure is comparable for FM and PMM cigarettes.

  7. The role of testing realism on experimentally obtained stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Whitfield, Richard C

    2011-01-01

    It has been shown (Hoffmann 2009) that pencil-and-paper tests, when used to determine stereotype strength, may yield data quite different to that obtained from hardware tests. The purpose of this research was to determine the level of realism required in order to have stereotypes that are consistent with real-world values. It is surprising that there does not appear to be any published research addressing this problem; all previous researches have considered either paper/pencil or hardware tests or sometimes both, but no level of simulation in between these techniques. In order to determine the effect of level of testing realism, a specific example was chosen to test, that of water tap operation stereotypes. Tests used verbal questioning, photographs of tap arrangements, a partial hardware arrangement and finally a full hardware setup. The results of these four levels of realism were very different and illustrated that, only with a full realistic simulation, did participants respond as might be expected in a real-world environment, illustrating the importance of testing realism when determining population stereotypes. This result has strong implications for product designers when selecting appropriate layouts of displays and controls and the linkages relating these.

  8. Spalling of concrete: A synthesis of experimental tests on slabs

    Directory of Open Access Journals (Sweden)

    Taillefer Nicolas

    2013-09-01

    Full Text Available The article reviews the results of many commercial or research tests carried out in CSTB on middle size concrete slabs. They concern 22 concrete slabs, made of normal and high strength concrete, for a rather wide range of thickness and compressive strength classes. Test procedures and a synthesis of main results are presented in order to provide deeper understanding of near-reality conditions of concrete structures. The tests concerned both new and existing tunnels. Results are detailed in relation with main parameters that are identified as impacting spalling in previous studies, such as concrete composition, concrete properties and specimen size.

  9. Experimental Test Plan for Grouting H-3 Calcine

    Energy Technology Data Exchange (ETDEWEB)

    Alan K. Herbst

    2006-01-01

    Approximately 4400 cubic meters of solid high-level waste called calcine are stored at the Idaho Nuclear Technology and Engineering Center. Under the Idaho Cleanup Project, dual disposal paths are being investigated. The first path includes calcine retrieval, package "as-is", and ship to the Monitored Geological Repository (MGR). The second path involves treatment of the calcine with such methods as vitrification or grouting. This test plan outlines the hot bench scale tests to grout actual calcine and verify that the waste form properties meet the waste acceptance criteria. This is a necessary sequential step in the process of qualifying a new waste form for repository acceptance. The archive H-3 calcine samples at the Contaminated Equipment Maintenance Building attached to New Waste Calcining Facility will be used in these tests at the Remote Analytical Laboratory. The tests are scheduled for the second quarter of fiscal year 2007.

  10. Reliability of four experimental mechanical pain tests in children

    Directory of Open Access Journals (Sweden)

    Soee AL

    2013-02-01

    Full Text Available Ann-Britt L Soee,1 Lise L Thomsen,2 Birte Tornoe,1,3 Liselotte Skov11Department of Pediatrics, Children’s Headache Clinic, Copenhagen University Hospital Herlev, Copenhagen, Denmark; 2Department of Neuropediatrics, Juliane Marie Centre, Copenhagen University Hospital Rigshospitalet, København Ø, Denmark; 3Department of Physiotherapy, Medical Department O, Copenhagen University Hospital Herlev, Herlev, DenmarkPurpose: In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT in healthy children. Furthermore, the aim was also to study the intersession reliability of the following four tests: (1 Total Tenderness Score; (2 PPT; (3 Visual Analog Scale score at suprapressure pain threshold; and (4 area under the curve (stimulus–response functions for pressure versus pain.Participants and methods: Twenty-five healthy school children, 8–14 years of age, participated. Test 2, PPT, was repeated three times at 2 minute intervals on the same day to estimate PPT intrasession reliability using Cronbach’s alpha. Tests 1–4 were repeated after median 21 (interquartile range 10.5–22 days, and Pearson’s correlation coefficient was used to describe the intersession reliability.Results: The PPT test was precise and reliable (Cronbach’s alpha ≥ 0.92. All tests showed a good to excellent correlation between days (intersessions r = 0.66–0.81. There were no indications of significant systematic differences found in any of the four tests between days.Conclusion: All tests seemed to be reliable measurements in pain evaluation in healthy children aged 8–14 years. Given the small sample size, this conclusion needs to be confirmed in future studies.Keywords: repeatability, intraindividual reliability, pressure pain threshold, pain measurement, algometer

  11. [Animal experimental tests of a new filling material (Isocap)].

    Science.gov (United States)

    Riethe, P; Rotgans, J; Schmalz, G

    1978-09-01

    An experimental investigation with animals (Rhesus monkeys) concerning pulp tolerance to two premeasured dosages of calcium hydroxide cement (Reocap and Reocap-E) as well as a pre-measured dosage of filling material (Isocap) in an injection capsule was carried out (78 class V cavities). As with the negative controls, a very slight reaction, or none at all, developed in response to the two calcium hydroxide cements and the new filling material, with and without application of capping material. When five other accidentally exposed pulpae were dissected, direct capping under the corresponding preconditions (punctate exposed pulpa, longer storage period for calcium hydroxide cement) showed the characteristic formation of reparative dentin.

  12. Big Bounce Genesis and Possible Experimental Tests -- A Brief Review

    CERN Document Server

    Cheung, Yeuk-Kwan E; Vergados, J D

    2016-01-01

    We review the recent status of big bounce genesis as a new possibility of using dark matter particle's mass and interaction cross section to test the existence of a bounce universe at the early stage of evolution in our currently observed universe. To study the dark matter production and evolution inside the bounce universe, called big bounce genesis for short, we propose a model independent approach. We shall present the motivation for proposing big bounce as well the model independent predictions which can be tested by dark matter direct searches. A positive finding shall have profound impact on our understanding of the early universe physics.

  13. Big Bounce Genesis and Possible Experimental Tests: A Brief Review

    Directory of Open Access Journals (Sweden)

    Yeuk-Kwan Edna Cheung

    2016-11-01

    Full Text Available We review the recent status of big bounce genesis as a new possibility of using dark matter particles’ mass and interaction cross-section to test the existence of a bounce universe at the early stage of evolution in our currently-observed universe. To study the dark matter production and evolution inside the bounce universe, called big bounce genesis for short, we propose a model independent approach. We shall present the motivation for proposing big bounce, as well as the model independent predictions, which can be tested by dark matter direct searches. A positive finding shall have profound impact on our understanding of the early universe physics.

  14. Experimental testing of moorings for large floating wave energy converters

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Ferri, Francesco; Kofoed, Jens Peter

    2016-01-01

    This paper presents the outcome of a test campaign, which investigates the behaviour of a synthetic mooring system applied to the Floating Power Plant wave energy converter. The study investigates the motion and tension response under operational and extreme sea states expected at the deployment...

  15. Interlayer tunnelling mechanism : experimental test of single layer compounds

    NARCIS (Netherlands)

    Tsvetkov, AA; van der Marel, D; Dulic, D; Molegraaf, HJ; Kolesnikov, NN; Willemsen, B; Ren, ZF; Bozovic,; Pavuna, D

    1998-01-01

    The c-axis optical properties of cuprate superconductors have been studied by grazing angle reflectivity technique. We tested the interlayer tunnelling (ILT) model of high temperature superconductivity and showed that the basic relation between the condensation energy of the superconducting state

  16. Interlayer tunnelling mechanism : experimental test of single layer compounds

    NARCIS (Netherlands)

    Tsvetkov, AA; van der Marel, D; Dulic, D; Molegraaf, HJ; Kolesnikov, NN; Willemsen, B; Ren, ZF; Bozovic,; Pavuna, D

    1998-01-01

    The c-axis optical properties of cuprate superconductors have been studied by grazing angle reflectivity technique. We tested the interlayer tunnelling (ILT) model of high temperature superconductivity and showed that the basic relation between the condensation energy of the superconducting state an

  17. Experimental testing of moorings for large floating wave energy converters

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Ferri, Francesco; Kofoed, Jens Peter

    2016-01-01

    This paper presents the outcome of a test campaign, which investigates the behaviour of a synthetic mooring system applied to the Floating Power Plant wave energy converter. The study investigates the motion and tension response under operational and extreme sea states expected at the deployment ...

  18. Preliminary design of mesoscale turbocompressor and rotordynamics tests of rotor bearing system

    Science.gov (United States)

    Hossain, Md Saddam

    2011-12-01

    A mesoscale turbocompressor spinning above 500,000 RPM is evolutionary technology for micro turbochargers, turbo blowers, turbo compressors, micro-gas turbines, auxiliary power units, etc for automotive, aerospace, and fuel cell industries. Objectives of this work are: (1) to evaluate different air foil bearings designed for the intended applications, and (2) to design & perform CFD analysis of a micro-compressor. CFD analysis of shrouded 3-D micro compressor was conducted using Ansys Bladegen as blade generation tool, ICEM CFD as mesh generation tool, and CFX as main solver for different design and off design cases and also for different number of blades. Comprehensive experimental facilities for testing the turbocompressor system have been also designed and proposed for future work.

  19. Design and experimental tests of free electron laser wire scanners

    Science.gov (United States)

    Orlandi, G. L.; Heimgartner, P.; Ischebeck, R.; Loch, C. Ozkan; Trovati, S.; Valitutti, P.; Schlott, V.; Ferianis, M.; Penco, G.

    2016-09-01

    SwissFEL is a x-rays free electron laser (FEL) driven by a 5.8 GeV linac under construction at Paul Scherrer Institut. In SwissFEL, wire scanners (WSCs) will be complementary to view-screens for emittance measurements and routinely used to monitor the transverse profile of the electron beam during FEL operations. The SwissFEL WSC is composed of an in-vacuum beam-probe—motorized by a stepper motor—and an out-vacuum pick-up of the wire signal. The mechanical stability of the WSC in-vacuum hardware has been characterized on a test bench. In particular, the motor induced vibrations of the wire have been measured and mapped for different motor speeds. Electron-beam tests of the entire WSC setup together with different wire materials have been carried out at the 250 MeV SwissFEL Injector Test Facility (SITF, Paul Scherrer Institut, CH) and at FERMI (Elettra-Sincrotrone Trieste, Italy). In particular, a comparative study of the relative measurement accuracy and the radiation-dose release of Al (99 )∶Si (1 ) and tungsten (W) wires has been carried out. On the basis of the outcome of the bench and electron-beam tests, the SwissFEL WSC can be qualified as a high resolution and machine-saving diagnostic tool in consideration of the mechanical stability of the scanning wire at the micrometer level and the choice of the wire material ensuring a drastic reduction of the radiation-dose release with respect to conventional metallic wires. The main aspects of the design, laboratory characterization and electron beam tests of the SwissFEL WSCs are presented.

  20. Single Component Sorption-Desorption Test Experimental Design Approach Discussions

    Energy Technology Data Exchange (ETDEWEB)

    Phil WInston

    2011-09-01

    A task was identified within the fission-product-transport work package to develop a path forward for doing testing to determine behavior of volatile fission products behavior and to engage members of the NGNP community to advise and dissent on the approach. The following document is a summary of the discussions and the specific approaches suggested for components of the testing. Included in the summary isare the minutes of the conference call that was held with INL and external interested parties to elicit comments on the approaches brought forward by the INL participants. The conclusion was that an initial non-radioactive, single component test will be useful to establish the limits of currently available chemical detection methods, and to evaluated source-dispersion uniformity. In parallel, development of a real-time low-concentration monitoring method is believed to be useful in detecting rapid dispersion as well as desorption phenomena. Ultimately, the test cycle is expected to progress to the use of radio-traced species, simply because this method will allow the lowest possible detection limits. The consensus of the conference call was that there is no need for an in-core test because the duct and heat exchanger surfaces that will be the sorption target will be outside the main neutron flux and will not be affected by irradiation. Participants in the discussion and contributors to the INL approach were Jeffrey Berg, Pattrick Calderoni, Gary Groenewold, Paul Humrickhouse, Brad Merrill, and Phil Winston. Participants from outside the INL included David Hanson of General Atomics, Todd Allen, Tyler Gerczak, and Izabela Szlufarska of the University of Wisconsin, Gary Was, of the University of Michigan, Sudarshan Loyalka and Tushar Ghosh of the University of Missouri, and Robert Morris of Oak Ridge National Laboratory.

  1. Experimental Testing Of Partially Encased Composite Beam Columns

    Directory of Open Access Journals (Sweden)

    Ehab M. Hanna

    2016-01-01

    Full Text Available The past few decades have seen outstanding advances in the use of composite materials in structural applications. There can be little doubt that, within engineering circles, composites have revolutionized traditional design concepts and made possible an unparalleled range of new and exciting possibilities as viable materials for construction. In addition to the well-known advantages of composite columns, partially encased composite columns offered simplified beam-to-column connection as well as reduced or omitted shuttering thus achieved more cost effective construction. Some companies have patented these new types of partially encased composite column made of light welded steel shapes; moreover, the Canadian Institute of Steel construction CISC has recognized and codified this type of columns. In This paper, Partially Encased Composite Beam Columns is introduced; experimental studies are made on five partially encased beam columns to investigate the behavior of eccentrically loaded partially encased composite columns using different parameters.

  2. Mode i testing of adhesive joints: Experimental part

    Energy Technology Data Exchange (ETDEWEB)

    Noekkentved, A. [Risoe National Lab., Materials Research Dept., Roskilde (Denmark)

    2006-07-01

    The J integral approach for adhesive bonded joints is particularly attractive for modelling failure process zones. The J integral can be established by a general approach and experimental measurements. By this method, the cohesive law of the adhesive in question can be obtained. Polymer joints with different mechanical properties and geometries are considered in order to study the effect of plasticity within the bond of ductile adhesives, since this can enhance their fracture toughness. The cohesive laws established will be implemented in numerical models - more in part 2. The objective of the project is to establish and demonstrate methods for modelling the mechanical behaviour of adhesively bonded joints in polymer matrix composite materials. Fracture mechanics will assist to establish the relevant framework for their mechanical performance. The main results from this study are expected to be part in a set of recommendations regarding production parameters, design, inspection and control of adhesively bonded joints. (au)

  3. Experimental tests for characterization of GPR antenna patterns

    Directory of Open Access Journals (Sweden)

    L. Versino

    1994-06-01

    Full Text Available Detection and location of buried structures using the electromagnetic impulsive methodologies (GPR require the study of the spatial distribution of energy irradiated by an antenna into the ground and the mechanisms of wave propagation and scattering from relevant targets. Evaluation of the difference in wave field distribution in the ground with respect to free space can provide some useful indications on the propagation of the Geo-radar signal in the ground and the spatial resolution capability of the GPR method. For this reason, a research group, involving “La Sapienza” University, Rome and the National Research Council began, during 1992, to perform studies on antenna radiation pattern, the propagation and scattering phenomena of GPR. This paper presents the experimental set up and the obtained results on the antenna radiation pattern.

  4. PLANCK, the Satellite: a New Experimental Test of General Relativity

    Directory of Open Access Journals (Sweden)

    Borissova L.

    2008-04-01

    Full Text Available If the origin of a microwave background (EMB is the Earth, what would be its density and associated dipole anisotropy measured at different altitudes from the surface of the Earth? The mathematical methods of the General Theory of Relativity are applied herein to answer these questions. The density of the EMB is answered by means of Einstein’s equations for the electromagnetic field of the Earth. The dipole anisotropy, which is due to the rapid motion of the source (the Earth in the weak intergalactic field, is analysed by using the geodesic equations for light-like particles (photons, which are mediators for electromagnetic radiation. It is shown that the EMB decreases with altitude so that the density of its energy at the altitude of the COBE orbit (900km is 0.68 times less than that at the altitude of a U2 aeroplane (25 km. Furthermore, the density at the 2nd Lagrange point (1.5 million km, the position of the WMAP and PLANCK satellites should be only 1E-7 of the value detected by a U2 aeroplane or at the COBE orbit. The dipole anisotropy of the EMB doesn’t depend on altitude from the surface of the Earth, it should be the same irrespective of the altitude at which measurements are taken. This result is in support to the experimental and observational analysis conducted by P.-M. Robitaille, according to which the 2.7 K microwave background, first observed by Penzias and Wilson, is not of cosmic origin, but of the Earth, and is generated by the oceans. WMAP indicated the same anisotropy of the microwave background at the 2nd Lagrange point that near the Earth. Therefore when PLANCK, which is planned on July, 2008, will manifest the 2.7 K monopole microwave signal deceased at the 2nd Langrange point, it will be a new experimental verification of Einstein’s theory.

  5. High-resolution cross-borehole thermal tracer testing in granite: preliminary field results

    Science.gov (United States)

    Brixel, Bernard; Klepikova, Maria; Jalali, Mohammadreza; Amann, Florian; Loew, Simon

    2017-04-01

    Understanding how heat is transported, stored and exchanged across fractured media is becoming increasingly relevant in our society, as manifested from the growing popularity of modern technologies relying on the subsurface to either source or store heat. One good example is the utilization of heat from deep hydrothermal or petrothermal systems to generate electricity for base load power generation, a technology also known as deep geothermal energy (DGE). While very attractive in principle, the number of geothermal fields producing economical levels of electricity to this day is still very limited - largely due to the difficulty of either locating deep reservoirs that are both sufficiently hot and permeable or, in the absence of the latter, creating them. In this context, the Swiss Competence Center for Energy Research - Supply of Electricity (SCCER - SoE) is carrying out an in situ stimulation and circulation (ISC) experiment at the Grimsel Test Site (GTS), an underground rock lab located in the Aar massif, in the Swiss Alps. The circulation experiment planned for the post-stimulation phase represents one of the key components of this experimental research program, and the outcome of this test is expected to ultimately provide key insights in the factors controlling the performance of enhanced geothermal reservoirs. Therefore, to support the design of this experiment, short-term thermal tracer tests (TTT) were conducted with the objective to (i) assess the feasibility of conducting TTTs in a relatively intact granite (where fluid flow is controlled by a limited number of discrete fractures); (ii) determine optimal experimental setups; and to ultimately (iii) monitor thermal breakthroughs at high spatial and temporal resolution, providing insights on heat transport and complementing the characterization of hydrogeological conditions carried out through conventional means (e.g. hydraulic and/or solute tracer tests). Presented herein are the results of a 10-day

  6. An experimental test of filter-aided dichromatic color discrimination.

    Science.gov (United States)

    Richer, S; Adams, A J

    1984-04-01

    Using derived formulas for dichromat colorimetry and related computer graphic colorimetric tools, predictions of color discrimination performance are made for a deuteranope and protanope standard observer for each of three commercial color deficiency "treatment" filters. Five deuteranopes and five protanopes then participated in two experiments. They were asked to order the caps of the D-15 test, and in a second experiment arrange color pairs (from the D-15 test) in order of difference. Predictions and subject performance reveal that although X-Chrom aided dichromats gain both luminous and chromatic information, all dichromats used predominantly chromaticity information in discrimination tasks. The colorimetric tools correctly predicted that protanopes would derive less useful luminous information from the X-Chrom filter compared with deuteranopes , and correctly predicted an increase in discrimination of blues and purples for both classes of red-green color deficients .

  7. Software Considerations for Subscale Flight Testing of Experimental Control Laws

    Science.gov (United States)

    Murch, Austin M.; Cox, David E.; Cunningham, Kevin

    2009-01-01

    The NASA AirSTAR system has been designed to address the challenges associated with safe and efficient subscale flight testing of research control laws in adverse flight conditions. In this paper, software elements of this system are described, with an emphasis on components which allow for rapid prototyping and deployment of aircraft control laws. Through model-based design and automatic coding a common code-base is used for desktop analysis, piloted simulation and real-time flight control. The flight control system provides the ability to rapidly integrate and test multiple research control laws and to emulate component or sensor failures. Integrated integrity monitoring systems provide aircraft structural load protection, isolate the system from control algorithm failures, and monitor the health of telemetry streams. Finally, issues associated with software configuration management and code modularity are briefly discussed.

  8. Analyses of the OSU-MASLWR Experimental Test Facility

    OpenAIRE

    2012-01-01

    Today, considering the sustainability of the nuclear technology in the energy mix policy of developing and developed countries, the international community starts the development of new advanced reactor designs. In this framework, Oregon State University (OSU) has constructed, a system level test facility to examine natural circulation phenomena of importance to multi-application small light water reactor (MASLWR) design, a small modular pressurized water reactor (PWR), relying on natural cir...

  9. Preliminary Results from Second Phase Sea Testing of the Wave Dragon Prototype Wave Energy Converter

    DEFF Research Database (Denmark)

    Soerensen, Hans Chr.; Tedd, James; Friis-Madsen, Erik;

    2006-01-01

    In March 2006 the prototype Wave Dragon has been redeployed to a more energetic site in Nissum Bredning an inland sea in Western Denmark. This has followed a period of renovation of many aspects of the device which have resulted in 20% higher energy output. This paper describes the preliminary re...

  10. Preliminary Results from Second Phase Sea Testing of the Wave Dragon Prototype Wave Energy Converter

    DEFF Research Database (Denmark)

    Soerensen, Hans Chr.; Tedd, James; Friis-Madsen, Erik

    2006-01-01

    In March 2006 the prototype Wave Dragon has been redeployed to a more energetic site in Nissum Bredning an inland sea in Western Denmark. This has followed a period of renovation of many aspects of the device which have resulted in 20% higher energy output. This paper describes the preliminary...

  11. Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.

    Energy Technology Data Exchange (ETDEWEB)

    Sobolik, Steven Ronald; Bartel, Lewis Clark

    2010-11-01

    correctly image the tunnel. This report represents a preliminary step in the development of a methodology to convert numerical predictions of rock properties to an estimation of the extent of rock damage around an underground facility and its corresponding seismic velocity, and the corresponding application to design a testing methodology for tunnel detection.

  12. PRELIMINARY FRIT DEVELOPMENT AND MELT RATE TESTING FOR SLUDGE BATCH 6 (SB6)

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K.; Miller, D.; Edwards, T.

    2009-07-21

    The Liquid Waste Organization (LWO) provided the Savannah River National Laboratory (SRNL) with a Sludge Batch 6 (SB6) composition projection in March 2009. Based on this projection, frit development efforts were undertaken to gain insight into compositional effects on the predicted and measured properties of the glass waste form and to gain insight into frit components that may lead to improved melt rate for SB6-like compositions. A series of Sludge Batch 6 (SB6) based glasses was selected, fabricated and characterized in this study to better understand the ability of frit compositions to accommodate uncertainty in the projected SB6 composition. Acceptable glasses (compositions where the Product Composition Control System (PCCS) Measurement Acceptability Region (MAR) predicted acceptable properties, good chemical durability was measured, and no detrimental nepheline crystallization was observed) can be made using Frit 418 with SB6 over a range of Na{sub 2}O and Al{sub 2}O{sub 3} concentrations. However, the ability to accommodate variation in the sludge composition limits the ability to utilize alternative frits for potential improvements in melt rate. Frit 535, which may offer improvements in melt rate due to its increased B2O3 concentration, produced acceptable glasses with the baseline SB6 composition at waste loadings of 34 and 42%. However, the PCCS MAR results showed that it is not as robust as Frit 418 in accommodating variation in the sludge composition. Preliminary melt rate testing was completed in the Melt Rate Furnace (MRF) with four candidate frits for SB6. These four frits were selected to evaluate the impacts of B{sub 2}O{sub 3} and Na{sub 2}O concentrations in the frit relative to those of Frit 418, although they are not necessarily candidates for SB6 vitrification. Higher concentrations of B{sub 2}O{sub 3} in the frit relative to that of Frit 418 appeared to improve melt rate. However, when a higher concentration of B{sub 2}O{sub 3} was coupled

  13. Advantages of the experimental animal hollow organ mechanical testing system for the rat colon rupture pressure test

    National Research Council Canada - National Science Library

    Ji, Chengdong; Guo, Xuan; Li, Zhen; Qian, Shuwen; Zheng, Feng; Qin, Haiqing

    2013-01-01

    .... A task force developed the experimental animal hollow organ mechanical testing system to provide precise measurement of the maximum pressure that an anastomotic colon can withstand, and to compare...

  14. New lab-made coagulant based on Schinopsis balansae tannin extract: synthesis optimization and preliminary tests on refractory water pollutants

    Science.gov (United States)

    Sánchez-Martín, J.; Beltrán-Heredia, J.; Coco-Rivero, B.

    2014-09-01

    Quebracho colorado tannin extract was used as a coagulant raw material for water and wastewater treatment. The chemical synthesis follows a Mannich reaction mechanism and provides a fully working coagulant that can remove several pollutants from water. This paper addresses the optimization of such synthesis and confirms the feasibility of the coagulant by testing it in a preliminary screening for the elimination of dyes and detergents. The optimum combination of reagents was 6.81 g of diethanolamine (DEA) and 2.78 g of formaldehyde (F) per g of tannin extract. So obtained coagulant was succesfully tested on the removal of 9 dyes and 8 detergents.

  15. Comparing effects of tillage treatments performed with animal traction on soil physical properties and soil electrical resistivity: preliminary experimental results

    Directory of Open Access Journals (Sweden)

    García-Tomillo Aitor

    2017-02-01

    Full Text Available Soil Compaction results from compressive forces applied to compressible soil by machinery wheels, combined with tillage operations. Draft animal‐pulled equipment may also cause soil compaction, but a huge gap exists on experimental data to adequately assess their impacts and, actually, animal traction is an option seen with increasing potential to contribute to sustainable agriculture, especially in mountain areas. This study was conducted to assess the impacts on soil compaction of tillage operations with motor tractor and draft animals. In a farm plot (Vale de Frades, NE Portugal treatments were applied in sub‐plots (30 m × 3 m, consisting in a two way tillage with tractor (T, a pair of cows (C and a pair of donkeys (D. Undisturbed soil samples (120 were taken before and after operations for bulk density (BD and saturated hydraulic conductivity (Ks. The relative changes in BD observed after tillage in the 0-0.05 m soil depth increased after operations in all treatments. The increase was higher in the tractor sub-plot (15% than in those where animal traction was used (8%. Before operation Ks class was rapid and fast in all samples, and after operation this value was reduced to 33% in T, whereas it reached 83% in C. Electrical Resistivity Tomography (ERT was useful as a tool to identify the alterations caused by tillage operations on soil physical status. These preliminary results confirm the potential of animal traction as an option for mountain agri‐environments, yet it requires much wider research to soundly ground its assets.

  16. 76 FR 3679 - Market Test of Experimental Product: “Marketing Mail Made Easy”

    Science.gov (United States)

    2011-01-20

    ... of Experimental Product: ``Marketing Mail Made Easy'' AGENCY: Postal Service TM . ACTION: Notice. SUMMARY: The Postal Service gives notice of a market test of an experimental product in accordance with... 39 U.S.C. 3641(c)(1) that it will begin a market test of its ``Marketing Mail Made...

  17. Development and first experimental tests of Faraday cup array.

    Science.gov (United States)

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed.

  18. Experimental tests of a gas fired adsorption air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Poyelle, F.; Guilleminot, J.J.; Meunier, F. [C.N.R.S.-L.I.M.S.I., Orsay Cedex (France); Canal, P.; Soide, I.; Klemsdal, E. [Gaz de Francer Saint Denis La Plaine (France)

    1997-10-01

    Over recent years, there has been growing interest for air conditioning systems, for commercial and offices buildings, transport and residential houses. Gaz de France promote natural gas powered air conditioning systems through the installation of commercial absorption machines, producing chilled and/or hot water. These machines cover loads from 70 kW to 5 MW. Gaz de France`s purpose is to develop a small scale natural gas fueled air conditioning system for residential applications and small commercials (5-20 kW). In order to study the feasibility of a small scale adsorption machine, a prototype has been studied, designed, constructed and tested. (au) 11 refs.

  19. Reliability of four experimental mechanical pain tests in children

    DEFF Research Database (Denmark)

    Søe, Ann-Britt Langager; Thomsen, Lise L; Tornoe, Birte

    2013-01-01

    In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim...... was also to study the intersession reliability of the following four tests: (1) Total Tenderness Score; (2) PPT; (3) Visual Analog Scale score at suprapressure pain threshold; and (4) area under the curve (stimulus-response functions for pressure versus pain)....

  20. The CAST (Childhood Asperger Syndrome Test): preliminary development of a UK screen for mainstream primary-school-age children.

    Science.gov (United States)

    Scott, Fiona J; Baron-Cohen, Simon; Bolton, Patrick; Brayne, Carol

    2002-03-01

    The article describes a pilot and follow-up study of the preliminary development of a new tool to screen for Asperger syndrome (AS) and related social and communication conditions (the Childhood Asperger Syndrome Test, CAST) in children aged 4-11 years, in a non-clinical setting. In the pilot study, parents of 13 children with AS and of 37 typically developing children completed the CAST. There were significant differences between the AS and typical sample means. The pilot was used to establish preliminary cut-off scores for the CAST. In the main study, parents of 1150 primary-school-age children were sent the CAST, and 174 took part in the full data analysis. Results suggest that compared with other tools currently available, the CAST may be useful for identifying children at risk for AS and related conditions, in a mainstream non-clinical sample. Further research is ongoing.

  1. Using eDNA to experimentally test ungulate browsing preferences.

    Science.gov (United States)

    Nichols, Ruth V; Cromsigt, Joris P G M; Spong, Göran

    2015-01-01

    Large herbivores may affect ecosystem processes and states, but such effects can be difficult to quantify, especially within multispecies assemblages. To better understand such processes and improve our predictive ability of systems undergoing change, herbivore diets can be studied using controlled feeding trials (or cafeteria tests). With some wildlife, such as large herbivores, it is impractical to empirically verify these findings, because it requires visually observing animals in forested environments, which can disturb them from their natural behaviors. Yet, in field-based cafeteria trials it is nearly impossible to differentiate selection between herbivore species that forage on similar plants and make very similar bite marks. However, during browsing ungulates leave saliva residue which includes some buccal cells and DNA that can be extracted for species identification. Here we used a newly developed eDNA-based method (biteDNA) to test the browsing preferences of four sympatric ungulate species in the wild. Overall, food preferences varied between species, but all species strongly preferred deciduous over coniferous species. Our method allows the study of plant-animal interactions in multispecies assemblages at very fine detail.

  2. Calculation and experimental test of the cooling factor of tungsten

    Science.gov (United States)

    Pütterich, T.; Neu, R.; Dux, R.; Whiteford, A. D.; O'Mullane, M. G.; Summers, H. P.; ASDEX Upgrade Team

    2010-02-01

    The cooling factor of W is evaluated using state of the art data for line radiation and an ionization balance which has been benchmarked with experiment. For the calculation of line radiation, level-resolved calculations were performed with the Cowan code to obtain the electronic structure and excitation cross sections (plane-wave Born approximation). The data were processed by a collisional radiative model to obtain electron density dependent emissions. These data were then combined with the radiative power derived from recombination rates and bremsstrahlung to obtain the total cooling factor. The effect of uncertainties in the recombination rates on the cooling factor was studied and was identified to be of secondary importance. The new cooling factor is benchmarked, by comparisons of the line radiation with spectral measurements as well as with a direct measurement of the cooling factor. Additionally, a less detailed calculation using a configuration averaged model was performed. It was used to benchmark the level-resolved calculations and to improve the prediction on radiation power from line radiation for ionization stages which are computationally challenging. The obtained values for the cooling factor validate older predictions from the literature. Its ingredients and the absolute value are consistent with the existing experimental results regarding the value itself, the spectral distribution of emissions and the ionization equilibrium. A table of the cooling factor versus electron temperature is provided. Finally, the cooling factor is used to investigate the operational window of a fusion reactor with W as intrinsic impurity. The minimum value of nTτE, for which a thermonuclear burn is possible, is increased by 20% for a W concentration of 3.0 × 10-5 compared with a plasma without any impurities, except for the He ash which is considered in both cases.

  3. Preliminary Feasibility, Design, and Hazard Analysis of a Boiling Water Test Loop Within the Idaho National Laboratory Advanced Test Reactor National Scientific User Facility

    Energy Technology Data Exchange (ETDEWEB)

    Douglas M. Gerstner

    2009-05-01

    The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The ATR and its support facilities are located at the Idaho National Laboratory (INL). A Boiling Water Test Loop (BWTL) is being designed for one of the irradiation test positions within the. The objective of the new loop will be to simulate boiling water reactor (BWR) conditions to support clad corrosion and related reactor material testing. Further it will accommodate power ramping tests of candidate high burn-up fuels and fuel pins/rods for the commercial BWR utilities. The BWTL will be much like the pressurized water loops already in service in 5 of the 9 “flux traps” (region of enhanced neutron flux) in the ATR. The loop coolant will be isolated from the primary coolant system so that the loop’s temperature, pressure, flow rate, and water chemistry can be independently controlled. This paper presents the proposed general design of the in-core and auxiliary BWTL systems; the preliminary results of the neutronics and thermal hydraulics analyses; and the preliminary hazard analysis for safe normal and transient BWTL and ATR operation.

  4. Experimental Testing of the Langlee Wave Energy Converter

    DEFF Research Database (Denmark)

    Lavelle, John; Kofoed, Jens Peter

    2011-01-01

    arrangement, with the flaps placed symmetrically opposing each other on a floating reference structure. This minimises the net force on the reference frame and increases the stability of the reference frame under optimal wave conditions. This paper presents the results and analysis from the wave tanks, which...... addressed the following: The Power Take Offs (PTOs) were simulated using a motor to resist the motion of the wings, according to the damping profile. Torque and velocity measurements were used to predict the wave- to mechanical-power conversion efficiency of the device. A number of wing types...... and configurations were tested to compare their power conversion efficiency. The power production for five selected irregular wave states was used to estimate the power matrix of the full scale the device, by making certain assumptions about the power conversion efficiencies dependency on the peak wave height...

  5. Proposed experimental test of the theory of hole superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, J.E., E-mail: jhirsch@ucsd.edu

    2016-06-15

    Highlights: • The conventional theory of superconductivity predicts no charge flow when the normal-superconductor phase boundary moves. • The theory of hole superconductivity predicts flow and counterflow of charge. • An experiment to measure a voltage is proposed. • No voltage will be measured if the conventional theory is correct. • A voltage will be measured if the theory of hole superconductivity is correct. - Abstract: The theory of hole superconductivity predicts that in the reversible transition between normal and superconducting phases in the presence of a magnetic field there is charge flow in direction perpendicular to the normal-superconductor phase boundary. In contrast, the conventional BCS-London theory of superconductivity predicts no such charge flow. Here we discuss an experiment to test these predictions.

  6. Augmented dry cooling surface test program: analysis and experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Parry, H.L.; MacGowan, L.J.; Kreid, D.K.; Wiles, L.E.; Faletti, D.W.; Johnson, B.M.

    1979-09-01

    Experiments were performed to assess the operating characteristics and potential performance of water-augmented dry cooling systems. The work was aimed at evaluating a deluged air-cooled HOETERV plate fin heat exchanger surface proposed for integrated dry/wet cooling systems and using test results to guide the development of a predictive analytical model. In the process, all-dry performance data were obtained for the HOETERV surface as well as for two Curtiss-Wright chipped fin surfaces. The dry heat transfer data indicate that a slotted Curtiss-Wright surface slightly outperforms the HOETERV and nonslotted Curtiss-Wright surfaces based on heat rejection rate per unit of fan power. However, all three surfaces are so close in performance that other factors, such as surface cost and piping and mounting costs, will probably determine which surface is preferred at a given installation. Comparisons of deluged HOETERV performance with dry HOETERV and Curtiss-Wright performance under prototypic conditions have established that deluging can provide considerable heat rejection enhancement, particularly at low ITD and low air humidity. A deluged HOETERV core operating at a 115/sup 0/F primary fluid temperature in 105/sup 0/F air at 10% relative humidity can reject over 7 times as much heat as a dry HOETERV core operating under the same conditions at the same air-side pressure drop. Deluged tests were performed to evaluate the effect of airflow rate, deluge flow rate and core tilt angle on performance. Both increased airflow and increased deluge flow increase both heat rejection rate and required fan power. Optimal airflow rate will thus be determined for a given location by the competing costs of heat exchanger surface area versus fan operation. Changes in core tilt angle from vertical to 16/sup 0/ from vertical have a negligible effect on performance.

  7. Experimental toxoplasmosis and vaccine tests in Aotus monkeys.

    Science.gov (United States)

    Escajadillo, A; Frenkel, J K

    1991-04-01

    We studied Aotus lemurinus, Panamanian night monkeys, for susceptibility to Toxoplasma infection and for their capacity to develop immunity using either sufadiazine prophylaxis or the non-persistent ts-4 vaccine. The animals were highly susceptible to infection with a mouse pathogenic (T265) and a mouse nonpathogenic (T163) Toxoplasma isolate. A calculated single bradyzoite by mouth gave rise to infection which was fatal in nine to 12 days. Chemoprophylaxis with 60-300 of sulfadiazine mg per day for up to 40 days protected the animals; however this was followed by fatal reactivation of infection between 11 and 70 days after treatment was stopped. Vaccination was carried out in two or three doses subcutaneously. Challenge was performed in 26 animals using both Toxoplasma isolates. Five monkeys (19%) survived for over a year, 10 died after a prolonged illness, and 11 died as rapidly as the seven controls. Safety tests showed the vaccine to be nonpathogenic in 111 adults except for slight fever and local inflammation, although one of four juveniles died from disseminated infection. Vaccination of 25 pregnant monkeys was non-pathogenic; however two of 25 fetuses were aborted, one of which was infected and one newborn had microphthalmia, retinitis and a cataract; four of the offspring were not tested. When six lactating monkeys were vaccinated, Toxoplasma was not transmitted to the infants. The high susceptibility to Toxoplasma and the low immunizability was circumstantially attributed to absence of exposure and lack of selection by Toxoplasma of these arboreal monkeys even though about 50% of terrestrial animals from the same area were infected.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Proposed use of a digital signal processor in an experimental tactile hearing aid for the profoundly deaf: preliminary communication.

    Science.gov (United States)

    Mathijssen, R W; Leliveld, W H

    1989-01-01

    An experimental system for a tactile hearing aid using a digital signal processor (DSP) is being developed. This system can be used to test and evaluate not only the familiar techniques for a tactile hearing aid, such as energy level display, filterbank analysis, etc., but also novel techniques. The system is being developed especially to try out new recognition strategies, because the currently available strategies are not satisfactory. A portable tactile hearing aid that can recognize certain environmental sounds (alarm sounds) and certain features from the speech signal (such as pitch, voiced/voiceless, or even complete phonemes), being a good support for lipreading, should be the final result of the experiments.

  9. Experimental testing of flexible barriers for containment of debris flows

    Science.gov (United States)

    DeNatale, Jay S.; Iverson, Richard M.; Major, Jon J.; LaHusen, Richard G.; Fliegel, Gregg L.; Duffy, John D.

    1999-01-01

    In June 1996, six experiments conducted at the U.S. Geological Survey Debris Flow Flume demonstrated that flexible, vertical barriers constructed of wire rope netting can stop small debris flows. All experimental debris flows consisted of water-saturated gravelly sand with less than two percent finer sediment by weight. All debris flows had volumes of about 10 cubic meters, masses of about 20 metre tons, and impact velocities of 5 to 9 meters per second. In four experiments, the debris flow impacted pristine, unreformed barriers of varying design; in the other two experiments, the debris flow impacted barriers already loaded with sediment from a previous flow. Differences in barrier design led to differences in barrier performance. Experiments were conducted with barriers constructed of square-mesh wire-rope netting with 30centimeter, 20centimeter, and 15 centimeter mesh openings as well as 30centimeter diameter interlocking steel rings. In all cases, sediment cascading downslope at the leading edge of the debris flows tended to spray through the nets. Nets fitted with finer-mesh chain link or chicken wire liners contained more sediment than did unlined nets, and a ring net fitted with a synthetic silt screen liner contained nearly 100 percent of the sediment. Irreversible net displacements of up to 2 meters and friction brake engagement on the support and anchor cables dissipated some of the impact energy. However, substantial forces developed in the steel support columns and the lateral and tie-back anchor cables attached to these columns. As predicted by elementary mechanics, the anchor cables experienced larger tensile forces when the support columns were hinged at the base rather than bolted rigidly to the foundation. Measured loads in the lateral anchor cables exceeded those in the tie-back anchor cables and the load cell capacity of 45 kilo-Newtons. Measurements also indicated that the peak loads in the tie- back anchors were highly transient and occurred at

  10. Effects of palliative care training program on knowledge, attitudes, beliefs and experiences among student physiotherapists: A preliminary quasi-experimental study

    Directory of Open Access Journals (Sweden)

    Senthil P Kumar

    2011-01-01

    Full Text Available Background: Physiotherapists play an inherent role in the multidisciplinary palliative care team. Existing knowledge, attitudes, beliefs and experiences influence their team participation in palliative care. Aims: The objective of this study was to assess the changes in knowledge, attitudes, beliefs and experiences among student physiotherapists who attended a palliative care training program. Settings and Design: Preliminary quasi-experimental study design, conducted at an academic institution. Materials and Methods: Fifty-two student physiotherapists of either gender (12 male, 40 female of age (20.51±1.78 years who attended a palliative care training program which comprised lectures and case examples of six-hours duration participated in this study. The study was performed after getting institutional approval and obtaining participants′ written informed consent. The lecture content comprised WHO definition of palliative care, spiritual aspects of life, death and healing, principles, levels and models of palliative care, and role of physiotherapists in a palliative care team. The physical therapy in palliative care-knowledge, attitudes, beliefs and experiences scale (PTiPC-KABE Scale- modified from palliative care attitudes scale were used for assessing the participants before and after the program. Statistical Analysis: Paired t-test and Wilcoxon signed rank test at 95% confidence interval using SPSS 11.5 for Windows. Results: Statistically significant differences (P<0.05 were noted for all four subscales- knowledge (7.84±4.61 points, attitudes (9.46±8.06 points, beliefs (4.88±3.29 points and experiences (15.8±11.28 points out of a total score of 104 points. Conclusions: The focus-group training program produced a significant positive change about palliative care in knowledge, attitudes, beliefs and experiences among student physiotherapists.

  11. Experimental testing of spanwise morphing trailing edge concept

    Science.gov (United States)

    Pankonien, Alexander; Inman, Daniel J.

    2013-04-01

    Aircraft wings with smooth, hinge-less morphing ailerons exhibit increased chordwise aerodynamic efficiency over conventional hinged ailerons. Ideally, the wing would also use these morphing ailerons to smoothly vary its airfoil shape between spanwise stations to optimize the lift distribution and further increase aerodynamic efficiency. However, the mechanical complexity or added weight of achieving such a design has traditionally exceeded the potential aerodynamic gains. By expanding upon the previously developed cascading bimorph concept, this work uses embedded Macro-Fiber Composites and a flexure box mechanism, created using multi-material 3D printing, to achieve the Spanwise Morphing Trailing Edge (SMTE) concept. The morphing actuators are spaced spanwise along the wing with an elastomer spanning the gaps between them, which allows for optimization of the spanwise lift distribution while maintaining the continuity and efficiency of the morphing trailing edge. The concept is implemented in a representative section of a UAV wing with a 305 mm chord. A novel honeycomb skin is created from an elastomeric material using a 3D printer. The actuation capabilities of the concept are evaluated with and without spanning material on a test stand, free of aerodynamic loads. In addition, the actuation restrictions of the spanning elastomer, necessary in adapting the morphing concept from 2D to 3D, are characterized. Initial aerodynamic results from the 1'×1' wind-tunnel also show the effects of aerodynamic loading on the actuation range of the SMTE concept for uniform morphing.

  12. Experimental testing and evaluation of cracks defects in line pipe

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, Ali; Cronin, Duane; Plumtree, Alan [University of Waterloo, Waterloo, Ontario (Canada); Kania, Richard [TransCanada Pipelines, Calgary, AB (Canada)

    2010-07-01

    Aging pipelines may show environmental or stress-induced cracking or similar defects. Several assessment methods are currently used for crack-like defects, as well as numerical modeling approaches. All have been used successfully, but unknown factors are the degree of conservatism and sensitivity to the various input parameters. To fill this knowledge gap, a series of full-scale burst tests was undertaken and successfully completed on end-capped, seam-welded pipe specimens having a 20-inch diameter and 5.7-mm wall thickness. The purpose was to study the failure behaviour of axial surface crack flaws and determine if the Level 3 FAD approach, NG-18 method and CorLAS can be applied to predict failure. The aspect of the fracture surface showed that the cause of failure of the pipe sections was ductile tearing, as expected in view of the material and crack sizes. It was found that the most accurate predictions were obtained with Level 3 FAD (J approach, using the cylinder equations) and CorLAS.

  13. Nuclear maintenance strategy and first steps for preliminary maintenance plan of the EU HCLL & HCPB Test Blanket Systems

    Energy Technology Data Exchange (ETDEWEB)

    Galabert, Jose, E-mail: jose.galabert@f4e.europa.eu [F4E Fusion for Energy, EU Domestic Agency, c/Josep Pla, 2. B3, 08019, Barcelona (Spain); Hopper, Dave [AMEC Foster Wheeler, Faraday Street, Birchwood Park, WA3 6GN (United Kingdom); Neviere, Jean-Cristophe [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, 13067, St. Paul Lez Durance Cedex (France); Nodwell, David [CCFE, Culham Science Centre, Abingdon, OX14 3DB, Oxfordshire (United Kingdom); Pascal, Romain [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, 13067, St. Paul Lez Durance Cedex (France); Poitevin, Yves; Ricapito, Italo [F4E Fusion for Energy, EU Domestic Agency, c/Josep Pla, 2. B3, 08019, Barcelona (Spain); White, Gareth [AMEC Foster Wheeler, Faraday Street, Birchwood Park, WA3 6GN (United Kingdom)

    2017-03-15

    Highlights: • Nuclear maintenance strategy for the two European (EU) Test Blanket Systems (TBS): i/. Helium Cooled Lead Lithium (HCLL) and ii/. Helium Cooled Pebble Bed (HCPB). • Preliminary identification of maintenance tasks for most relevant components of the EU HCLL & HCPB TBS. • Preliminary feasibility analysis for hands-on maintenance tasks of some relevant components of the European Test Blanket Systems. • Design recommendations for enhancement of the European Test Blanket Systems maintainability. - Abstract: This paper gives an overview of nuclear maintenance strategy to be followed for the European HCLL & HCPB Test Blanket Systems (TBS) to be installed in ITER. One of the several core documents to prepare in view of their licensing is their respective ‘Maintenance Plan’. This document is fundamental for ensuring sound performance and safety of the TBS during ITER’s operational phase and shall include, amongst others, relevant information on: maintenance organization, preventive and corrective maintenance task procedures, condition monitoring for key components, maintenance work planning, and a spare parts plan, just to mention some of the key topics. In compliance with the ITER Plant Maintenance policy, first steps have been taken aimed at defining nuclear maintenance strategy for some of the most relevant HCLL & HCPB TBS components, conducted by F4E in collaboration with industry. After a brief recall of maintenance strategy of the TBM Program (PBS-56), this paper analyses main features of EU HCLL & HCPB TBS maintainability and identifies, at their conceptual design phase, a preliminary list of maintenance tasks to be developed for their most representative components. In addition, the paper also presents the first nuclear maintenance studies conducted for replacement of the Q{sub 2} Getter Beds, identifying some design recommendations for their sound maintainability.

  14. GUEST EDITORS' INTRODUCTION: Testing inversion algorithms against experimental data: inhomogeneous targets

    Science.gov (United States)

    Belkebir, Kamal; Saillard, Marc

    2005-12-01

    This special section deals with the reconstruction of scattering objects from experimental data. A few years ago, inspired by the Ipswich database [1 4], we started to build an experimental database in order to validate and test inversion algorithms against experimental data. In the special section entitled 'Testing inversion algorithms against experimental data' [5], preliminary results were reported through 11 contributions from several research teams. (The experimental data are free for scientific use and can be downloaded from the web site.) The success of this previous section has encouraged us to go further and to design new challenges for the inverse scattering community. Taking into account the remarks formulated by several colleagues, the new data sets deal with inhomogeneous cylindrical targets and transverse electric (TE) polarized incident fields have also been used. Among the four inhomogeneous targets, three are purely dielectric, while the last one is a `hybrid' target mixing dielectric and metallic cylinders. Data have been collected in the anechoic chamber of the Centre Commun de Ressources Micro-ondes in Marseille. The experimental setup as well as the layout of the files containing the measurements are presented in the contribution by J-M Geffrin, P Sabouroux and C Eyraud. The antennas did not change from the ones used previously [5], namely wide-band horn antennas. However, improvements have been achieved by refining the mechanical positioning devices. In order to enlarge the scope of applications, both TE and transverse magnetic (TM) polarizations have been carried out for all targets. Special care has been taken not to move the target under test when switching from TE to TM measurements, ensuring that TE and TM data are available for the same configuration. All data correspond to electric field measurements. In TE polarization the measured component is orthogonal to the axis of invariance. Contributions A Abubakar, P M van den Berg and T M

  15. Progeny test of tetraploid Betula platyphylla and preliminary selection of hybrid parents

    Institute of Scientific and Technical Information of China (English)

    Huanwen Xu; Yu Liu; Jing Jiang; Guifeng Liu; Xiyang Zhao

    2016-01-01

    Estimating genetic parameters of parental lines through progeny testing and choosing good hybrid parents are important for genetically improving seed orchard trees. In this study, 24 tetraploid progeny seedlings were used as experimental materials, which came from test cross design:six tetraploid Betula platyphylla lines (Q33, Q13, Q103, Q19, Q83 and Q14) as female parents and four individual B. platyphylla diploid lines (F3, F4, F9 and F11) as male parents were crossed. Variance analysis of height, diame-ter, height-to-diameter ratio, and internodal distance showed that the differences between hybrid combinations reached highly significant levels. Using multi-objective decisionmaking, we performed a comprehensive assess-ment of the various hybrid combinations. Using a selection rate of 20% of the standard, five hybrids were selected;their genetic gains in average height, diameter, height-to-diameter ratio, and internodal distance were 20.95, 6.07, 13.07 and 8.96%, respectively. We also analyzed the combining ability and genetic parameter effect values of parents and hybrid combinations. The combined analysis revealed that Q13, Q103, Q33 and Q83 were superior females; F3, F4, and F9 were superior males; and F3 9 Q13, F4 9 Q83 and F9 9 Q33 were superior hybrid combinations. The heights and diameters of these proge-nies were 22.49 and 11.48% greater than average, respectively.

  16. Experimental tests on a new harvesting system for Burley tobacco

    Directory of Open Access Journals (Sweden)

    Salvatore Faugno

    2013-09-01

    Full Text Available The globalization of the tobacco production has led to a drop in competitiveness of the Italian tobacco on the world market. Burley is the main variety of tobacco cropped in Campania region of Southern Italy. Its leaves have to be sewn, in the curing phase. Aim of this work is to show the results of the implementation of a new harvest machine prototype. Basically, the machine used for Bright tobacco, totally mechanical harvested, which doesn’t need to be sewn because it requires an indirect-fire treatment into the curing furnaces. The machine was modified in order to mechanize harvesting of Burley tobacco, and tested on four cultivars of Burley tobacco under three different planting layouts. The Burley tobacco leaves can be harvested mechanically by pulling individual leaves off the stalk; leaves are then sorted and tied in bundles prior to sewing. A mechanical burley tobacco harvesting system was evaluated. This machine consists in realizing a leaves orientation system based on the different weight between the leaf blade and the stalk enhanced by an air flow. The measurements taken were harvest timing, work capacity, and quality standards of the work carried out. The results, in terms of user time, range from 6.67 h/ha to 7.80 h/ha while in terms of operational efficiency are between 88% and 89%. The average user capacity recorded for the four cultivars is equal to 0.14 ha/h, a value far from the one recorded for the same harvesting machine used for Bright tobacco (0.25 ha/h. The harvest timing capacity, range from 0.51 t/h to 0.99 t/h. The work productivity goes from 0.17 t to 0.33 t per hour of human unit respectively. The average number of detached leaves, depending on the cultivar, has been between 523 and 744. Concerning the leaf orientation, a general percentage of 73% was achieved.

  17. User attitudes in analyzing digital slides in a quality control test bed: a preliminary study.

    Science.gov (United States)

    Della Mea, Vincenzo; Demichelis, Francesca; Viel, Federico; Dalla Palma, Paolo; Beltrami, Carlo Alberto

    2006-05-01

    The pathologist examines suitably stained glass slides through a bright field microscope in order to render histopathological or cytological diagnosis by looking at tissues and cells. Glass slides serve as a permanent record of the patient disease. Over the course of a patient's treatment slides may need to be reviewed at other institutions before treatment can commence. Due to their fragile nature a transportable permanent digital facsimile of the glass slide would be ideal. A digital slide is a set of digital images representing the whole slide normally used by the pathologist, or a significant part of it; it is usually made by a large amount of images, up to thousands, which makes its management difficult. The present paper provides a description of the requirements needed to reproduce glass slides and of the available technological equipment, then the features of the two systems we implemented on different hardware are described, together with those of the digital slide viewer. The viewer was evaluated in two experimental test phases, during which user behaviour and diagnostic reports were measured. Digital slides used in the two experiments were acquired with either system. Possible applications of digital slides are then discussed, including undergraduate and professional education, quality control, and image analysis on full samples as well as on tissue microarrays.

  18. Fish-Friendly Hydropower Turbine Development & Deployment: Alden Turbine Preliminary Engineering and Model Testing

    Energy Technology Data Exchange (ETDEWEB)

    Foust, J. [Voith Hydro, Inc., York, PA (USA); Hecker, G. [Alden Research Laboratory, Inc., Holden, MA (USA); Li, S. [Alden Research Laboratory, Inc., Holden, MA (USA); Allen, G. [Alden Research Laboratory, Inc., Holden, MA (USA)

    2011-10-01

    The Alden turbine was developed through the U.S. Department of Energy's (DOE's) former Advanced Hydro Turbine Systems Program (1994-2006) and, more recently, through the Electric Power Research Institute (EPRI) and the DOE's Wind & Water Power Program. The primary goal of the engineering study described here was to provide a commercially competitive turbine design that would yield fish passage survival rates comparable to or better than the survival rates of bypassing or spilling flow. Although the turbine design was performed for site conditions corresponding to 92 ft (28 m) net head and a discharge of 1500 cfs (42.5 cms), the design can be modified for additional sites with differing operating conditions. During the turbine development, design modifications were identified for the spiral case, distributor (stay vanes and wicket gates), runner, and draft tube to improve turbine performance while maintaining features for high fish passage survival. Computational results for pressure change rates and shear within the runner passage were similar in the original and final turbine geometries, while predicted minimum pressures were higher for the final turbine. The final turbine geometry and resulting flow environments are expected to further enhance the fish passage characteristics of the turbine. Computational results for the final design were shown to improve turbine efficiencies by over 6% at the selected operating condition when compared to the original concept. Prior to the release of the hydraulic components for model fabrication, finite element analysis calculations were conducted for the stay vanes, wicket gates, and runner to verify that structural design criteria for stress and deflections were met. A physical model of the turbine was manufactured and tested with data collected for power and efficiency, cavitation limits, runaway speed, axial and radial thrust, pressure pulsations, and wicket gate torque. All parameters were observed to fall

  19. Identification of problem Neisseria gonorrhoeae cultures by standard and experimental tests.

    Science.gov (United States)

    Arko, R J; Finley-Price, K G; Wong, K H; Johnson, S R; Reising, G

    1982-01-01

    Standard and experimental tests were used by a reference diagnostic laboratory to determine the identity of 182 "suspected" Neisseria gonorrhoeae isolates submitted by state health departments because of inconclusive laboratory results. More than 97% of these cultures were subsequently identified by a rapid microcarbohydrate test in conjunction with confirmatory immunological procedures. The experimental rapid slide agglutination test using rough-lipopolysaccharide antibody, the Phadebact co-agglutination test, and fluorescent antibody test identified 49.3 to 94.1% of these cultures. Because of frequent problems with carbohydrate utilization, Neisseria meningitidis and Branhamella catarrhalis were the two microorganisms most often confused with N. gonorrhoeae by submitting laboratories. PMID:6804485

  20. Design and preliminary test of a free-air ionization chamber for low-energy X-ray

    Institute of Scientific and Technical Information of China (English)

    WU Jin-Jie; YANG Yuan-Di; WANG Pei-Wei; CHEN Jing; LIU Jia-Cheng

    2011-01-01

    A free-air ionization chamber in low-energy X-ray has been designed and manufactured at theNational Institute of Metrology (NIM, China) according to the defination of alr-kerma. The results of a preliminary test show that the leakage current of ionization chamber is around 2×10A, and the correction factor of ion recombination for the ionization chamber is also obtained. The free-air ionization chamber is suitable for the primary standard in low-energy X-rays.

  1. Observing the Testing Effect using Coursera Video-Recorded Lectures: A Preliminary Study.

    Science.gov (United States)

    Yong, Paul Zhihao; Lim, Stephen Wee Hun

    2015-01-01

    We investigated the testing effect in Coursera video-based learning. One hundred and twenty-three participants either (a) studied an instructional video-recorded lecture four times, (b) studied the lecture three times and took one recall test, or (c) studied the lecture once and took three tests. They then took a final recall test, either immediately or a week later, through which their learning was assessed. Whereas repeated studying produced better recall performance than did repeated testing when the final test was administered immediately, testing produced better performance when the final test was delayed until a week after. The testing effect was observed using Coursera lectures. Future directions are documented.

  2. Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10

    Science.gov (United States)

    Wu, Ke; Li, Zhen-Dong; Zhao, Jian-Fu; Li, Hui-Xiong; Li, Kai

    2016-05-01

    Focusing on partial nucleate pool boiling at low heat flux, SOBER-SJ10, one of 27 experiments of the program SJ-10, has been proposed to study local convection and heat transfer around an isolated growing vapor bubble during nucleate pool boiling on a well characterized flat surface in microgravity. An integrated micro heater has been developed. By using a local pulse overheating method in the experimental mode of single bubble boiling, a bubble nucleus can be excited with accurate spatial and temporal positioning on the top-side of a quartz glass substrate with a thickness of 2 mm and an effective heating area of 4.5 mm in diameter, and then grows under an approximate constant heat input provided by the main heater on the back-side of the substrate. Ten thin film micro-RTDs are used for local temperature measurements on the heating surface underneath the growing bubble. Normal pool boiling experiments can also be carried out with step-by-step increase of heating voltage. A series of ground test of the flight module of SOBER-SJ10 have been conducted. Good agreement of the measured data of single phase natural convection with the common-used empirical correlation warrants reasonable confidence in the data. It is found that the values of the incipience superheat of pool boiling at different subcooling are consistent with each others, verifying that the influence of subcooling on boiling incipience can be neglected. Pool boiling curves are also obtained, which shows great influence of subcooling on heat transfer of partial nucleate pool boiling, particularly in lower heat flux.

  3. Composite Failures: A Comparison of Experimental Test Results and Computational Analysis Using XFEM

    Science.gov (United States)

    2016-09-30

    availability of measurement techniques, experimental testing of composite materials has largely outpaced the computational modeling ability, forcing...Reinforced Composites Finite-Element Method Fracture Mechanics Physics- Based Modeling Extended Finite-Element...7 PHYSICS- BASED MODELING

  4. ANALYS OF EXPERIMENTAL HYBRID CAR TESTING RESULTS ON URBAN DRIVING CYCLE

    Directory of Open Access Journals (Sweden)

    S. Serikov

    2014-02-01

    Full Text Available The experimental hybrid car testing results are presented. The estimation of hybrid car draft-speed characteristics, energy and ecological indicators on urban driving cycle are given.

  5. An Experimental Test of the Effects of Gender Constancy on Sex Typing

    Science.gov (United States)

    Arthur, Andrea E.; Bigler, Rebecca S.; Ruble, Diane N.

    2009-01-01

    This study provides an experimental test of the hypothesis that level of gender constancy understanding affects children's sex typing. Preschool-age children (N = 62, mean age = 47 months) were randomly assigned to experimental lessons that taught that biological traits (including gender) are either fixed (pro-constancy condition) or mutable…

  6. EXPERIMENTAL TESTING OF DRAW-BEAD RESTRAINING FORCE IN SHEET METAL FORMING

    Institute of Scientific and Technical Information of China (English)

    J.H. Yang; J. Chen; D.N. He; X. Y. Ruan

    2003-01-01

    Due to complexities of draw-bead restraining force calculated according to theory anddepending on sheet metal forming properties experiment testing system, a simplifiedmethod to calculate draw-bead restraining force is put forward by experimental methodin cup-shaped drawing process. The experimental results were compared with numer-ical results and proved agreement. It shows the method is effective.

  7. Topics on Test Methods for Space Systems and Operations Safety: Applicability of Experimental Data

    Science.gov (United States)

    Hirsch, David B.

    2009-01-01

    This viewgraph presentation reviews topics on test methods for space systems and operations safety through experimentation and analysis. The contents include: 1) Perception of reality through experimentation and analysis; 2) Measurements, methods, and correlations with real life; and 3) Correlating laboratory aerospace materials flammability data with data in spacecraft environments.

  8. An experimental test of the local fluctuation theorem in chains of weakly interacting Anosov systems

    CERN Document Server

    Gallavotti, G; Gallavotti, Giovanni; Perroni, Fabio

    1999-01-01

    An experimental test of a large fluctuation theorem is performed on a chain of coupled ``cat maps''. Our interest is focused on the behavior of a subsystem of this chain. A local entropy creation rate is defined and we show that the local fluctuation theorem derived in [G1] is experimentally observable already for small subsystems.

  9. Geomechanical properties of Topopah Spring Tuff at the 0.5-m scale: preliminary results of compression tests at elevated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Blair, S. C., LLNL

    1997-08-25

    This report presents preliminary results of laboratory testing of a small block sample of Topopah Spring Tuff. This is the first in a series of tests on small block samples. The purpose of these tests is to investigate the thermal-mechanical, thermal-hydrological, and thermal-chemical response of the rock to conditions similar to the near-field environment (NFE) of a potential nuclear waste repository. This report presents preliminary results of deformation and elastic- wave velocity measurements on a 0.5-m scale block of Topopah Spring tuff tested in uniaxial compression and at temperatures to 85{degrees}C.

  10. Preliminary test results from a free-piston Stirling engine technology demonstration program to support advanced radioisotope space power applications

    Science.gov (United States)

    White, Maurice A.; Qiu, Songgang; Augenblick, Jack E.

    2000-01-01

    Free-piston Stirling engines offer a relatively mature, proven, long-life technology that is well-suited for advanced, high-efficiency radioisotope space power systems. Contracts from DOE and NASA are being conducted by Stirling Technology Company (STC) for the purpose of demonstrating the Stirling technology in a configuration and power level that is representative of an eventual space power system. The long-term objective is to develop a power system with an efficiency exceeding 20% that can function with a high degree of reliability for up to 15 years on deep space missions. The current technology demonstration convertors (TDC's) are completing shakedown testing and have recently demonstrated performance levels that are virtually identical to projections made during the preliminary design phase. This paper describes preliminary test results for power output, efficiency, and vibration levels. These early results demonstrate the ability of the free-piston Stirling technology to exceed objectives by approximately quadrupling the efficiency of conventional radioisotope thermoelectric generators (RTG's). .

  11. Experimental evaluation of the Battelle accelerated test design for the solar array at Mead, Nebraska

    Science.gov (United States)

    Frickland, P. O.; Repar, J.

    1982-01-01

    A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.

  12. Experimental evaluation of the Battelle accelerated test design for the solar array at Mead, Nebraska

    Science.gov (United States)

    Frickland, P. O.; Repar, J.

    1982-04-01

    A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.

  13. Preliminary benefit-cost analysis of the Fast Flux Test Facility (FFTF) power addition

    Energy Technology Data Exchange (ETDEWEB)

    Callaway, J.M.; Lezberg, A.J.; Scott, M.J.; Tawil, J.J.

    1984-07-01

    The primary objective of this report is to conduct a preliminary benefit-cost study for the proposed power addition to FFTF to determine whether the project is cost-effective. If the project is authorized, construction will begin in 1986 and end in 1991. Full power operation is scheduled to begin in 1991 and a project life of 20 years is assumed. The undiscounted cost during the construction period of the FFTF power addition is estimated to be approximately $117 million over the construction period (1984 dollars). An additional $3 million is estimated as the opportunity cost - or value of these resources in their most favorable alternative use - of surplus FFTF equipment and unused CRBR equipment, including materials for steam generator fabrication. The annual operating and maintenance cost of the project is estimated to be about $2.1 million in 1984 dollars. 20 references.

  14. Preliminary tests for Salix sp. tolerance to heavy metals (Cd, Ni, Pb)

    Science.gov (United States)

    Corneanu, Mihaela; Hernea, Cornelia; Butnariu, Monica; Corneanu, Gabriel; Sărac, Ioan; Hollerbach, Wilhelm; Neţoiu, Constantin; Petcov, Andreea Adriana

    2014-05-01

    The species of Salix genus constitute potential sources of germplasm in the prevention of the environment degradation, and offer remedy for about two third from the all degradation types. The majority of the willow species, present a good adaptation to hypoxic conditions, feature which suggest that they manifest a preference for mineral nutrition in comparison with organic one. Thus, many of willow species can be developed on soils with a big amount of minerals and/or radionuclides, being both phytoremediatory species, as well as pioneer ones, contributing to the restoration of soil. Thus, the willow species, posses the capacity for development in degraded areas, natural or anthropic, as swamps, abandoning crops areas, sandy dune, riparian sandy areas, gravels, a.o. In this paper are present some laboratory comparative tests of heavy metals tolerance on four Salix sp. genotypes: clone 202 (Salix alba), hybrid 892 (Salix alba), Inger (Salix viminalis) and Gudrun (Salix viminalis). The genotypes of Salix alba are native from Romania, produced in the Forest Research and Management Institute Bucharest, while the genotypes of Salix viminalis are native from Sweden, but the plant material was produced under license in Romania by REBINA Agrar SRL. As plant material were used one-year-old cuttings (5-10 cm long), with 2-6 buds each. Per genotype, per heavy metal and each of three concentration five replication were used. There were ten experimental variants for each genotype: three concentrations for each of the heavy metals; concentrations selected, in the accordance SR ISO 11269-2/March 1999 and Control (tap water). The cuttings were maintained in metalic solutions for 15 days. In the days 7th and 15th, were performed biometrical observations on: the roots number and length, the shoots number and length, the leaves number/shoot, viability of the shoots. At the end of the experiment the content in heavy metals was determined in roots and shoots (by atomic absorption

  15. [Official experimental testing of biomedical products. Regulatory frame and importance of for quality, safety and efficacy].

    Science.gov (United States)

    Vieths, S; Seitz, R

    2014-10-01

    The official experimental testing of biomedicinal products provides a very significant contribution to ensuring quality, safety and efficacy of these indispensable medicines. Already in the prelicensing phase or to elucidate clusters of increased adverse effects, official medicinal control laboratories are committed to perform experimental testing. The official batch release can be seen as external quality control of the manufacturer's release testing. For proficient performance in these tasks, scientific research is required, in particular on the development and refinement of test methods, and considering the continuous development of innovative biomedicinal products. This article is aimed at introducing the present thematic issue and in particular the regulatory basis of experimental product testing, and illustrates by means of several examples its great importance for the sake of the patients.

  16. Observing the Testing Effect using Coursera Video-recorded Lectures: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Paul Zhihao eYONG

    2016-01-01

    Full Text Available We investigated the testing effect in Coursera video-based learning. One hundred and twenty-three participants either (a studied an instructional video-recorded lecture four times, (b studied the lecture three times and took one recall test, or (c studied the lecture once and took three tests. They then took a final recall test, either immediately or a week later, through which their learning was assessed. Whereas repeated studying produced better recall performance than did repeated testing when the final test was administered immediately, testing produced better performance when the final test was delayed until a week after. The testing effect was observed using Coursera lectures. Future directions are documented.

  17. Preliminary Computational Study for Future Tests in the NASA Ames 9 foot' x 7 foot Wind Tunnel

    Science.gov (United States)

    Pearl, Jason M.; Carter, Melissa B.; Elmiligui, Alaa A.; WInski, Courtney S.; Nayani, Sudheer N.

    2016-01-01

    The NASA Advanced Air Vehicles Program, Commercial Supersonics Technology Project seeks to advance tools and techniques to make over-land supersonic flight feasible. In this study, preliminary computational results are presented for future tests in the NASA Ames 9 foot x 7 foot supersonic wind tunnel to be conducted in early 2016. Shock-plume interactions and their effect on pressure signature are examined for six model geometries. Near- field pressure signatures are assessed using the CFD code USM3D to model the proposed test geometries in free-air. Additionally, results obtained using the commercial grid generation software Pointwise Reigistered Trademark are compared to results using VGRID, the NASA Langley Research Center in-house mesh generation program.

  18. Validation of the finite element simulation to estimate the rolling resistance of a non-driving wheel with experimental tests

    Directory of Open Access Journals (Sweden)

    N Dibagar

    2015-09-01

    rubber materials for the tire. Tire model consisted of three components: tread, rubber and ring. Using a soil bin and one wheel tester with their related equipment, experimental tests were carried out in the workstation of mechanics of bio system engineering department of the Urmia University. This system includes various sections such as soil storage in dimensions of 22×2×1 meter, tools carrier or tracker, soil processing equipment, dynamic system, evaluation tools and controlling systems. In order to launch the collection and supply required power for wheel carrier, an industrial three phase electromotor with 22 kW (30 hp was used. Both numerical and experimental tests were done at three levels of wheel dynamic load (1, 2, 3, 4 and 5 kN, tire inflation pressure (100, 200 and 300 kPa and four levels of speed (0.25, 0.45, 0.65, 0.9 and 1.15 m s-1 to obtain the rolling resistance of the tire. Results and discussion: In order to evaluate the performance of final non driving tire-soil model to estimate the rolling resistance, numerical results were compared with preliminary experimental data obtained from the soil-bin tests. The comparison showed reasonably good agreement between the computed and measured general pattern of the rolling resistance at the tire-soil interface under different speeds, vertical loads and inflation pressures. In both tests, a specified relation was not seen between tire velocity and its rolling resistance, as it was not seen in empirical models such as Wismar and Luce. Correlation coefficient between experimental and numerical data, in the minimum and maximum value of tire inflation pressure was computed to be 0.06 and 0.016 percent, respectively. The amount of tire rolling resistance significantly increased with increase of tire vertical load. Correlation coefficient between experimental and numerical data, in the minimum and maximum vertical loads was computed to be 80 and 87 percent, respectively. Gent and Walter obtained the same results

  19. Validation of the finite element simulation to estimate the rolling resistance of a non-driving wheel with experimental tests

    Directory of Open Access Journals (Sweden)

    N Dibagar

    2015-09-01

    rubber materials for the tire. Tire model consisted of three components: tread, rubber and ring. Using a soil bin and one wheel tester with their related equipment, experimental tests were carried out in the workstation of mechanics of bio system engineering department of the Urmia University. This system includes various sections such as soil storage in dimensions of 22×2×1 meter, tools carrier or tracker, soil processing equipment, dynamic system, evaluation tools and controlling systems. In order to launch the collection and supply required power for wheel carrier, an industrial three phase electromotor with 22 kW (30 hp was used. Both numerical and experimental tests were done at three levels of wheel dynamic load (1, 2, 3, 4 and 5 kN, tire inflation pressure (100, 200 and 300 kPa and four levels of speed (0.25, 0.45, 0.65, 0.9 and 1.15 m s-1 to obtain the rolling resistance of the tire. Results and discussion: In order to evaluate the performance of final non driving tire-soil model to estimate the rolling resistance, numerical results were compared with preliminary experimental data obtained from the soil-bin tests. The comparison showed reasonably good agreement between the computed and measured general pattern of the rolling resistance at the tire-soil interface under different speeds, vertical loads and inflation pressures. In both tests, a specified relation was not seen between tire velocity and its rolling resistance, as it was not seen in empirical models such as Wismar and Luce. Correlation coefficient between experimental and numerical data, in the minimum and maximum value of tire inflation pressure was computed to be 0.06 and 0.016 percent, respectively. The amount of tire rolling resistance significantly increased with increase of tire vertical load. Correlation coefficient between experimental and numerical data, in the minimum and maximum vertical loads was computed to be 80 and 87 percent, respectively. Gent and Walter obtained the same results

  20. Preliminary evaluation of a micro-based repeated measures testing system

    Science.gov (United States)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  1. Preliminary Research Employing the Watson-Barker Listening Test: A Validation of the Instrument.

    Science.gov (United States)

    Roberts, Charles V.

    A study was conducted to further validate the "Watson-Barker Listening Test." The subjects, 120 students enrolled in basic speech courses, completed the Receiver Apprehension Test (RAT) and the Watson-Barker Listening Test: Form A. Statistical analysis of the results revealed a significant correlation between the RAT scores and both the long term…

  2. Experimental design and analysis for accelerated degradation tests with Li-ion cells.

    Energy Technology Data Exchange (ETDEWEB)

    Doughty, Daniel Harvey; Thomas, Edward Victor; Jungst, Rudolph George; Roth, Emanuel Peter

    2003-08-01

    This document describes a general protocol (involving both experimental and data analytic aspects) that is designed to be a roadmap for rapidly obtaining a useful assessment of the average lifetime (at some specified use conditions) that might be expected from cells of a particular design. The proposed experimental protocol involves a series of accelerated degradation experiments. Through the acquisition of degradation data over time specified by the experimental protocol, an unambiguous assessment of the effects of accelerating factors (e.g., temperature and state of charge) on various measures of the health of a cell (e.g., power fade and capacity fade) will result. In order to assess cell lifetime, it is necessary to develop a model that accurately predicts degradation over a range of the experimental factors. In general, it is difficult to specify an appropriate model form without some preliminary analysis of the data. Nevertheless, assuming that the aging phenomenon relates to a chemical reaction with simple first-order rate kinetics, a data analysis protocol is also provided to construct a useful model that relates performance degradation to the levels of the accelerating factors. This model can then be used to make an accurate assessment of the average cell lifetime. The proposed experimental and data analysis protocols are illustrated with a case study involving the effects of accelerated aging on the power output from Gen-2 cells. For this case study, inadequacies of the simple first-order kinetics model were observed. However, a more complex model allowing for the effects of two concurrent mechanisms provided an accurate representation of the experimental data.

  3. Experimental Testing Procedures and Dynamic Model Validation for Vanadium Redox Flow Battery Storage System

    DEFF Research Database (Denmark)

    Baccino, Francesco; Marinelli, Mattia; Nørgård, Per Bromand

    2013-01-01

    The paper aims at characterizing the electrochemical and thermal parameters of a 15 kW/320 kWh vanadium redox flow battery (VRB) installed in the SYSLAB test facility of the DTU Risø Campus and experimentally validating the proposed dynamic model realized in Matlab-Simulink. The adopted testing...

  4. The Development of an Experimental Sensory-Motor and Movement Skills Test Battery.

    Science.gov (United States)

    Orpet, Russel E.

    An age-normed test battery was developed for use as a research instrument to assess strengths and weaknesses in the sensory-motor development of elementary school age children. The importance of sensory-motor functions for the child's total development and learning is noted. The experimental sensory-motor test battery consists of 12 subtests, and…

  5. Experimental Test of Bell inequalities with Six-Qubit Graph States

    CERN Document Server

    Gao, Wei-Bo; Xu, Ping; Gühne, Otfried; Cabello, Adán; Lu, Chao-Yang; Yang, Tao; Chen, Zeng-Bing; Pan, Jian-Wei

    2009-01-01

    We report on the experimental realization of two different Bell inequality tests based on six-qubit linear-type and Y-shape graph states. For each of these states, the Bell inequalities tested are optimal in the sense that they provide the maximum violation among all Bell inequalities with stabilizing observables and possess the maximum resistance to noise.

  6. Preliminary Multirod Burst Test Program results and implications of interest to reactor safety evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, R.H. (comp.)

    1978-01-01

    The Multirod Burst Test (MRBT) Program, in progress at Oak Ridge National Laboratory, is investigating LWR cladding deformation in single- and multirod test arrays under conditions representative of reflood and refill phases of a LOCA. In these tests internally pressurized, unirradiated Zircaloy-4 tubes containing electrically heated fuel simulators are tested to failure in a low-pressure, superheated-steam environment. The tubes are ''uniformly'' heated over a 915-mm length; the simulator pressure, due to the small enclosed gas volume, also varies with temperature (and deformation) during the test. Two 4 x 4 multirod tests (B-1 and B-2), one with and one without the shroud being heated, have been conducted with a bundle heating rate of approx. 29/sup 0/C/sec; initial pressure conditions for these tests were selected to cause failure at about 860/sup 0/C. An additional 4 x 4 array (B-3) was tested using a bundle heating rate of approx. 10/sup 0/C/sec; the shroud was also heated in this test. Initial conditions were adjusted to cause failure at approx. 760/sup 0/C. Posttest examination (including flow tests) of the B-1 and B-2 test arrays, is essentially complete, and pertinent data are included in this summary.

  7. Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

    Science.gov (United States)

    Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc

    2014-01-01

    In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a

  8. Preliminary study of novel, timed walking tests for children with spina bifida or cerebral palsy

    Science.gov (United States)

    Kane, Kyra J; Lanovaz, Joel; Bisaro, Derek; Oates, Alison; Musselman, Kristin E

    2016-01-01

    Objective: Walking assessment is an important aspect of rehabilitation practice; yet, clinicians have few psychometrically sound options for evaluating walking in highly ambulatory children. The purpose of this study was to evaluate the validity and reliability of two new measures of walking function—the Obstacles and Curb tests—relative to the 10-Meter Walk test and Timed Up and Go test in children with spina bifida or cerebral palsy. Methods: A total of 16 ambulatory children with spina bifida (n=9) or cerebral palsy (n=7) (9 boys; mean age 7years, 7months; standard deviation 3years, 4months) and 16 age- and gender-matched typically developing children participated. Children completed the walking tests, at both self-selected and fast speeds, twice. To evaluate discriminative validity, scores were compared between typically developing and spina bifida/cerebral palsy groups. Within the spina bifida/cerebral palsy group, inter-test correlations evaluated convergent validity and intraclass correlation coefficients evaluated within-session test–retest reliability. Results: At fast speeds, all tests showed discriminative validity (p<0.006 for typically developing and spina bifida/cerebral palsy comparisons) and convergent validity (rho=0.81–0.90, p⩽0.001, for inter-test correlations). At self-selected speeds, only the Obstacles test discriminated between groups (p=0.001). Moderately strong correlations (rho=0.73–0.78, p⩽0.001) were seen between the 10-Meter Walk test, Curb test, and Timed Up and Go test. Intraclass correlation coefficients ranged from 0.81 to 0.97, with higher test–retest reliability for tests performed at fast speeds rather than self-selected speeds. Conclusion: The Obstacles and Curb tests are promising measures for assessing walking in this population. Performing tests at fast walking speeds may improve their validity and test–retest reliability for children with spina bifida/cerebral palsy. PMID:27493754

  9. Air STAR Beyond Visual Range UAS Description and Preliminary Test Results

    Science.gov (United States)

    Cunningham, Kevin; Cox, David E.; Foster, John V.; Riddick, Stephen E.; Laughter, Sean A.

    2016-01-01

    The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.

  10. Preliminary test results in support of integrated EPP and SMT design methods development

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanli [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jetter, Robert I. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sham, T. -L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-02-09

    The proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology consists of incorporating a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid using the creep-fatigue interaction diagram (the D diagram) and to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed code rules and to verify their applicability, a series of thermomechanical tests have been initiated. One test concept, the Simplified Model Test (SMT), takes into account the stress and strain redistribution in real structures by including representative follow-up characteristics in the test specimen. The second test concept is the two-bar thermal ratcheting tests with cyclic loading at high temperatures using specimens representing key features of potential component designs. This report summaries the previous SMT results on Alloy 617, SS316H and SS304H and presents the recent development on SMT approach on Alloy 617. These SMT specimen data are also representative of component loading conditions and have been used as part of the verification of the proposed integrated EPP and SMT design methods development. The previous two-bar thermal ratcheting test results on Alloy 617 and SS316H are also summarized and the new results from two bar thermal ratcheting tests on SS316H at a lower temperature range are reported.

  11. Quantifying microwear on experimental Mistassini quartzite scrapers: preliminary results of exploratory research using LSCM and scale-sensitive fractal analysis.

    Science.gov (United States)

    Stemp, W James; Lerner, Harry J; Kristant, Elaine H

    2013-01-01

    Although previous use-wear studies involving quartz and quartzite have been undertaken by archaeologists, these are comparatively few in number. Moreover, there has been relatively little effort to quantify use-wear on stone tools made from quartzite. The purpose of this article is to determine the effectiveness of a measurement system, laser scanning confocal microscopy (LSCM), to document the surface roughness or texture of experimental Mistassini quartzite scrapers used on two different contact materials (fresh and dry deer hide). As in previous studies using LSCM on chert, flint, and obsidian, this exploratory study incorporates a mathematical algorithm that permits the discrimination of surface roughness based on comparisons at multiple scales. Specifically, we employ measures of relative area (RelA) coupled with the F-test to discriminate used from unused stone tool surfaces, as well as surfaces of quartzite scrapers used on dry and fresh deer hide. Our results further demonstrate the effect of raw material variation on use-wear formation and its documentation using LSCM and RelA. © Wiley Periodicals, Inc.

  12. Evaluation of photopatch test allergens for Indian patients of photodermatitis: Preliminary results

    Directory of Open Access Journals (Sweden)

    Nidhi Jindal

    2011-01-01

    Full Text Available Background: There is a strong need to develop a photopatch test tray suitable for Indian patients of photodermatitis as European/Scandinavian photopatch test trays may not be wholly relevant for them. Aim: We carried out this study using photoallergens relevant in the Indian context to determine their relevance in patients of photodermatitis. Methods: Thirty patients (M:F, 23:7 between 19 and 76 years of age of photodermatitis and 10 controls were patch- and photopatch tested with 20 common photoallergens. In addition, the patients were also (photo patch tested with articles of daily use as and when these were suspected to be the cause. Results: Forty-three positive reactions to one or more antigens were seen in 22 (74% patients. Fourteen positive photopatch tests to seven allergens were observed in 10 (33% patients, and nine (30% of them had a definite relevance. The most common contact allergen was fragrance mix (FM (30%, followed by p-phenylenediamine (20% and Parthenium hysterophorous (17%. The definite relevance of the patch- and photopatch tests could be correlated in 47% of these patients. Conclusions: FM is the most common contact and photocontact allergen among the various photopatch test antigens. Although differences in technique and evaluation make direct comparison between different centers difficult, still photopatch testing remains an integral part and gold standard for the work-up of the photosensitive patients.

  13. A Preliminary Analysis of the Linguistic Complexity of Numeracy Skills Test Items for Pre Service Teachers

    Science.gov (United States)

    O'Keeffe, Lisa

    2016-01-01

    Language is frequently discussed as barrier to mathematics word problems. Hence this paper presents the initial findings of a linguistic analysis of numeracy skills test sample items. The theoretical perspective of multi-modal text analysis underpinned this study, in which data was extracted from the ten sample numeracy test items released by the…

  14. The effects of experimenter gender on state social physique anxiety and strength in a testing environment.

    Science.gov (United States)

    Lamarche, Larkin; Gammage, Kimberley L; Gabriel, David A

    2011-02-01

    Social influences can impact self-presentational concerns such as social physique anxiety (SPA), concerns over one's body being evaluated by others. In addition, social influences may also impact performance on a physical test. In a physical testing environment, one social factor that influences SPA and which may also influence the outcomes of a physical test is experimenter gender. The present study examined the influence of experimenter gender on SPA and actual muscle strength in an experimental testing environment. Male (n = 50) and female (n = 50) university students were randomly assigned to either a male or female experimenter. Before strength testing, state SPA (SPA-S) was assessed. Actual strength was represented by the score obtained during the maximum voluntary contraction (MVC) test. Two 2 × 2 (participant gender × gender of the experimenter) analyses of variance were conducted with SPA-S and strength as the dependent variables. For SPA-S, a significant main effect was found only for participant gender (F(1,95) = 14.08, p < 0.01, η² = 0.13), with women scoring significantly higher than men. For MVC, there was a significant effect for participant gender (F(1,96) = 48.08, p < 0.001, η² = 0.33), with men, as expected, having significantly higher strength values than women. Although the gender of the experimenter did not influence SPA-S or muscle strength, other forms of anxiety (e.g., fitness anxiety) may be relevant in this setting. Future research should also investigate other factors in the testing environment (e.g., type of task) that may be more influential on psychological or performance outcomes.

  15. Field Test Report: Preliminary Aquifer Test Characterization Results for Well 299-W15-225: Supporting Phase I of the 200-ZP-1 Groundwater Operable Unit Remedial Design

    Energy Technology Data Exchange (ETDEWEB)

    Spane, Frank A.; Newcomer, Darrell R.

    2009-09-23

    This report examines the hydrologic test results for both local vertical profile characterization and large-scale hydrologic tests associated with a new extraction well (well 299-W15-225) that was constructed during FY2009 for inclusion within the future 200-West Area Groundwater Treatment System that is scheduled to go on-line at the end of FY2011. To facilitate the analysis of the large-scale hydrologic test performed at newly constructed extraction well 299-W15-225 (C7017; also referred to as EW-1 in some planning documents), the existing 200-ZP-1 interim pump-and-treat system was completely shut-down ~1 month before the performance of the large-scale hydrologic test. Specifically, this report 1) applies recently developed methods for removing barometric pressure fluctuations from well water-level measurements to enhance the detection of hydrologic test and pump-and-treat system effects at selected monitor wells, 2) analyzes the barometric-corrected well water-level responses for a preliminary determination of large-scale hydraulic properties, and 3) provides an assessment of the vertical distribution of hydraulic conductivity in the vicinity of newly constructed extraction well 299-W15-225. The hydrologic characterization approach presented in this report is expected to have universal application for meeting the characterization needs at other remedial action sites located within unconfined and confined aquifer systems.

  16. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Science.gov (United States)

    Chernyshova, M.; Malinowski, K.; Czarski, T.; Wojeński, A.; Vezinet, D.; Poźniak, K. T.; Kasprowicz, G.; Mazon, D.; Jardin, A.; Herrmann, A.; Kowalska-Strzeciwilk, E.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P.

    2016-11-01

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  17. PHOEBUS/UHTREX: a preliminary study of a low-cost facility for transient tests of LMFBR fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, W.L. (comp.)

    1976-08-01

    The results of a brief preliminary design study of a facility for transient nuclear tests of fast breeder reactor fuel are described. The study is based on the use of a reactor building originally built for the UHTREX reactor, and the use of some reactor hardware and reactor design and fabrication technology remaining from the Phoebus-2 reactor of the Rover nulcear rocket propulsion program. The facility is therefore currently identified as the PHOEBUS/UHTREX facility. This facility is believed capable of providing early information regarding fast reactor core accident energetics issues which will be very valuable to the overall LMFBR safety program. Facility performance in conjunction with a reference 127-fuel pin experiment is described. Low cost and early availability of the facility were emphasized in the selection of design features and parameters.

  18. Design and preliminary test results of the 40 MW power supply at the National High Magnetic Field Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Boenig, H.J. [Los Alamos National Lab., NM (United States); Bogdan, F.; Morris, G.C. [ABB Drives Inc., New Berlin, WI (United States); Ferner, J.A.; Schneider-Muntau, H.J. [National High Magnetic Field Lab., Tallahassee, FL (United States); Rumrill, R.H.; Rumrill, R.S. [Alpha Scientific Electronics Inc., Hayward, CA (United States)

    1993-11-01

    Four highly stabilized, steady-state, 10 MW power supplies have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL. Each supply consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors and freewheeling diodes, and a passive and an active filter. Two different transformer tap settings allow dc supply output voltages of 400 and 500 V. The rated current of a supply is 17 kA and each supply has a one hour overload capability of 20 kA. The power supply output bus system, including a reversing switch at the input and 2 {times} 16 disconnect switches at the output, connects each supply to 16 different magnet cells. The design of the power supply is described and preliminary test results with a supply feeding a 10 MW resistive load are presented.

  19. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl; Malinowski, K.; Czarski, T.; Kowalska-Strzęciwilk, E. [Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw (Poland); Wojeński, A.; Poźniak, K. T.; Kasprowicz, G.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P. [Institute of Electronic Systems, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland); Vezinet, D.; Herrmann, A. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Mazon, D.; Jardin, A. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2016-11-15

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  20. Successful micronucleus testing with the EPI/001 3D reconstructed epidermis model: preliminary findings.

    Science.gov (United States)

    Andres, E; Molinari, J; Remoué, N; Sá-Rocha, V M; Barrichello, C; Hurtado, S P

    2012-03-18

    Currently, the cosmetics industry relies on the results of in vitro genotoxicity tests to assess the safety of chemicals. Although the cytokinesis-block micronucleus (CBMN) test for the detection of cells that have divided once is routinely used and currently accepted by regulatory agencies, it has some limitations. Reconstituted human epidermis (RHE) is widely used in safety assessments because its physiological properties resemble those of the skin, and because it allows testing of substances such as hydrophobic compounds. Thus, the micronucleus test is being adapted for application in RHE-reconstructed tissues. Here we investigated whether two different reconstructed epidermis models (EPI/001 from Straticell, and RHE/S/17 from Skinethic) are suitable for application of the micronucleus test. We found that acetone does not modify micronucleus frequency, cell viability, and model structure, compared with non-treated RHE. Treatment of the EPI/001 model with mitomycin C and vinblastine resulted in a dose-dependent increase of micronucleus frequency as well as a decrease of tissue viability and of binucleated cell rate, while no changes of the epidermal structure were observed. The number of binucleated cells obtained with the RHE/S/17 model was too small to permit micronucleus testing. These results indicate that the proliferative rate of the tissue used is a critical parameter in performing the micronucleus test on a 3D model.

  1. EXPERIMENTAL TESTING OF DRAW—BEAD RESTRAINING FORCE IN SHEET METAL FORMING

    Institute of Scientific and Technical Information of China (English)

    J.H.Yang; J.Chen; 等

    2003-01-01

    Due to complexities of draw-bead restraining force calculated according to theory and depending on sheet metal forming properties experiment testing system,a simplified method to calculate draw-bead restraining force is put forward by experimental method in cup-shaped drawing process.The experimental results were compared with numer-ical results and proved agreement.It shows the method is effective.

  2. Development of a Synchronous-Generator Experimental Bench for Standstill Time-Domain Tests

    Directory of Open Access Journals (Sweden)

    M.A. Arjona

    2011-08-01

    Full Text Available This paper presents the development of an experimental bench for performing time-domain tests on synchronousmachines at standstill. The test bench allows the collection of experimental data which can then be used in theparameter estimation of mathematical models of synchronous motors and generators. The system development isbased on the LabVIEW programming language. It effortlessly allows the calibration of voltage and current sensors, thed-q magnetic axis positioning of the synchronous generator, and the spectral analysis from the collected data. Inaddition, the testing environment includes non-sophisticated instrumentation elements and a power amplifier. Thisexperimental bench has a friendly user interface which guides the user throughout a defined methodology to allow theachievement of the different time domain tests on synchronous machines. A 7kVA, 220V, 60Hz synchronousgenerator was used to show the functionality and usefulness of the test bench in research and teaching electricalmachine theory.

  3. Modeling and experimental testing activity of the Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Hu, Junjie; Marinelli, Mattia

    cost investments of to the system operator, thus a proactive tap algorithm is developed and tested in this project, relying on local measurements. In addition, we also compared the experimental result with the one simulated in the DigSilent PowerFactory software environment (the software used...... the voltage problems in presence of photovoltaic distributed generation, using Bistrup distribution grid (DONG Energy) as a test case. This second report presents the experimental results of the testing activity of the Voltage Optimization Unit (VOU), i.e., a distribution transformer with single-phase on......-load tap changers (OLTC) in an experimental low voltage grid. Both the transformer internal behavior and its effective operations under different unbalanced bidirectional power flow conditions have been investigated. Moreover, different control logics are analyzed based on their control objectives and control...

  4. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  5. Preliminary experimental characterization of the ambient humidity response of Bi{sub 3}TiNbO{sub 9}

    Energy Technology Data Exchange (ETDEWEB)

    Galuppo, E; Avila, R E [Departamento de Materiales Nucleares, Comision Chilena de EnergIa Nuclear, Cas. 188-D, Santiago (Chile); Serafini, D [Departamento de Fisica, Universidad de Santiago de Chile, Santiago (Chile); Dudik, L [Electronics Design Center, Case Western Reserve University, Cleveland, OH (United States); Cabrera, A L [Departamento de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile)], E-mail: ravila@cchen.cl

    2008-11-01

    A preliminary electrical characterization of Bi{sub 3}TiNb0{sub 9} pellets, prepared by mechanochemical activation shows a nearly exponential conductivity increase over 4 orders of magnitude from dry ambient to dew point of 10 deg. C, at 23 deg. C ambient temperature; or 5 order of magnitude in thick films over interdigitated electrodes. Relaxation currents, following bias stress, respond also, at a lower sensitivity level. Under different DP on either electrode, the lower DP value controls the overall current, which flows through the bulk, not through the mantle of the cylindrical pellets. Repetitive cycling does not deteriorate the response to the ambient humidity.

  6. Uniaxial strength testing of Calico Hills tuff, Yucca Mountain: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qizhi; Schultz, R.A. [Univ. of Nevada, Reno, NV (United States)

    1994-12-31

    A detailed investigation of the strength properties of Calico Hills tuff was undertaken to further characterize the behavior of this unit. Uniaxial compression test on 47 samples of massive and reworked tuff show a dependence of peak strength and Young`s modulus on the total porosity, and thus on the geologic history of the Calico Hills tuff. Controlled deformation of test specimens documents axial splitting and faulting as failure mechanisms in the post-peak region of these brittle tuffs.

  7. Impact of Emotional Intelligence Enhancement on Test Anxiety among EFL Learners: an Experimental Study

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Ebrahimi

    2016-03-01

    Full Text Available Emotional Intelligence (EI also EQ is an affective factor capable of being enhanced, (Test Anxiety is another affective factor capable of being reduced. The present study is based on examination of possible impact(s of enhancing Emotional Intelligence on the reduction of Test Anxiety among Iranian university students. For this purpose, 45 students in intervention and control conditions completed the "Emotional Intelligence Questionnaire" and filled Sarason Test Anxiety Scale; afterwards, they received instructions on EQ and strategies to enhance it. At the end of the course, the same Test Anxiety Questionnaire was administered to the participants. By the use of descriptive statistics and independent samples t-test the data were analyzed. The analysis of the data uncovered that there is a significant difference in the reduction of students' Test Anxiety in experimental group. The results can shed light on how students’ emotional intelligence enhancement influences Test Anxiety and also possibly in a broader scale, testing outcomes.

  8. Factors associated with medical student test anxiety in objective structured clinical examinations: a preliminary study

    Science.gov (United States)

    2016-01-01

    Objectives To investigate attributes of medical students associated with their test anxiety on Objective Structured Clinical Examinations (OSCEs). Methods A cross-sectional study using a self-administered questionnaire was conducted of all Year 3 and 4 students at a private medical school in South Korea in 2014. This 53-item questionnaire consisted of factors pertaining to test anxiety on the OSCE identified from a review of relevant literature, which included students’ motivational beliefs and achievement emotions, perceived values of the OSCE, and attitude and orientation towards patients. Participants’ test anxiety levels were measured using the Korean Achievement Emotions Questionnaire. Participants rated their responses using a five-point Likert-type scale. Univariate analysis was performed to examine relationships between the variables. Results A total of 94 students completed the questionnaire (a 93% response rate). No differences in the participants’ test anxiety scores were observed across genders, entry-levels, or years in medical school. Participants’ test anxiety on the OSCE showed moderate association with their class-related achievement emotions (i.e., anxiety and boredom), where r = 0.46 and 0.32, p OSCE (r = -0.21, p OSCE. These findings have implications for developing effective educational interventions for helping students cope with such a stress by enhancing our understanding of the various factors that influence their test anxiety in OSCEs. PMID:28035056

  9. Factors associated with medical student test anxiety in objective structured clinical examinations: a preliminary study.

    Science.gov (United States)

    Kim, Kyong-Jee

    2016-12-29

    To investigate attributes of medical students associated with their test anxiety on Objective Structured Clinical Examinations (OSCEs). A cross-sectional study using a self-administered questionnaire was conducted of all Year 3 and 4 students at a private medical school in South Korea in 2014. This 53-item questionnaire consisted of factors pertaining to test anxiety on the OSCE identified from a review of relevant literature, which included students' motivational beliefs and achievement emotions, perceived values of the OSCE, and attitude and orientation towards patients. Participants' test anxiety levels were measured using the Korean Achievement Emotions Questionnaire. Participants rated their responses using a five-point Likert-type scale. Univariate analysis was performed to examine relationships between the variables. A total of 94 students completed the questionnaire (a 93% response rate). No differences in the participants' test anxiety scores were observed across genders, entry-levels, or years in medical school. Participants' test anxiety on the OSCE showed moderate association with their class-related achievement emotions (i.e., anxiety and boredom), where r = 0.46 and 0.32, p anxiety on the OSCE. These findings have implications for developing effective educational interventions for helping students cope with such a stress by enhancing our understanding of the various factors that influence their test anxiety in OSCEs.

  10. Selecting appropriate animal models and experimental designs for endocrine disruptor research and testing studies.

    Science.gov (United States)

    Stokes, William S

    2004-01-01

    Evidence that chemicals in the environment may cause developmental and reproductive abnormalities in fish and wildlife by disrupting normal endocrine functions has increased concern about potential adverse human health effects from such chemicals. US laws have now been enacted that require the US Environmental Protection Agency (EPA) to develop and validate a screening program to identify chemicals in food and water with potential endocrine-disrupting activity. EPA subsequently proposed an Endocrine Disruptor Screening Program that uses in vitro and in vivo test systems to identify chemicals that may adversely affect humans and ecologically important animal species. However, the endocrine system can be readily modulated by many experimental factors, including diet and the genetic background of the selected animal strain or stock. It is therefore desirable to minimize or avoid factors that cause or contribute to experimental variation in endocrine disruptor research and testing studies. Standard laboratory animal diets contain high and variable levels of phytoestrogens, which can modulate physiologic and behavioral responses similar to both endogenous estrogen as well as exogenous estrogenic chemicals. Other studies have determined that some commonly used outbred mice and rats are less responsive to estrogenic substances than certain inbred mouse and rat strains for various estrogen-sensitive endpoints. It is therefore critical to select appropriate biological models and diets for endocrine disruptor studies that provide optimal sensitivity and specificity to accomplish the research or testing objectives. An introduction is provided to 11 other papers in this issue that review these and other important laboratory animal experimental design considerations in greater detail, and that review laboratory animal and in vitro models currently being used or evaluated for endocrine disruptor research and testing. Selection of appropriate animal models and experimental design

  11. Engineering, Manufacture and Preliminary Testing of the ITER Toroidal Field (TF) Magnet Helium Cold Circulator

    Science.gov (United States)

    Rista, P. E. C.; Shull, J.; Sargent, S.

    2015-12-01

    The ITER cryodistribution system provides the supercritical Helium (SHe) forced flow cooling to the magnet system using cold circulators. The cold circulators are located in each of five separate auxiliary cold boxes planned for use in the facility. Barber-Nichols Inc. has been awarded a contract from ITER-India for engineering, manufacture and testing of the Toroidal Field (TF) Magnet Helium Cold Circulator. The cold circulator will be extensively tested at Barber-Nichols’ facility prior to delivery for qualification testing at the Japan Atomic Energy Agency's (JAEA) test facility at Naka, Japan. The TF Cold Circulator integrates features and technical requirements which Barber-Nichols has utilized when supplying helium cold circulators worldwide over a period of 35 years. Features include a vacuum-jacketed hermetically sealed design with a very low helium leak rate, a heat shield for use with both nitrogen & helium cold sources, a broad operating range with a guaranteed isentropic efficiency over 70%, and impeller design features for high efficiency. The cold circulator will be designed to meet MTBM of 17,500 hours and MTBF of 36,000 hours. Vibration and speed monitoring are integrated into a compact package on the rotating assembly with operation and health monitoring in a multi-drop PROFIBUS communication environment using an electrical cabinet with critical features and full local and network PLC interface and control. For the testing in Japan and eventual installation in Europe, the cold circulator must be certified to the Japanese High Pressure Gas Safety Act (JHPGSA) and CE marked in compliance with the European Pressure Equipment Directive (PED) including Essential Safety Requirements (ESR). The test methodology utilized at Barber-Nichols’ facility and the resulting test data, validating the high efficiency of the TF Cold Circulator across a broad operating range, are important features of this paper.

  12. Advantages of the experimental animal hollow organ mechanical testing system for the rat colon rupture pressure test.

    Science.gov (United States)

    Ji, Chengdong; Guo, Xuan; Li, Zhen; Qian, Shuwen; Zheng, Feng; Qin, Haiqing

    2013-01-01

    Many studies have been conducted on colorectal anastomotic leakage to reduce the incidence of anastomotic leakage. However, how to precisely determine if the bowel can withstand the pressure of a colorectal anastomosis experiment, which is called anastomotic bursting pressure, has not been determined. A task force developed the experimental animal hollow organ mechanical testing system to provide precise measurement of the maximum pressure that an anastomotic colon can withstand, and to compare it with the commonly used method such as the mercury and air bag pressure manometer in a rat colon rupture pressure test. Forty-five male Sprague-Dawley rats were randomly divided into the manual ball manometry (H) group, the tracing machine manometry pressure gauge head (MP) group, and the experimental animal hollow organ mechanical testing system (ME) group. The rats in each group were subjected to a cut colon rupture pressure test after injecting anesthesia in the tail vein. Colonic end-to-end anastomosis was performed, and the rats were rested for 1 week before anastomotic bursting pressure was determined by one of the three methods. No differences were observed between the normal colon rupture pressure and colonic anastomotic bursting pressure, which were determined using the three manometry methods. However, several advantages, such as reduction in errors, were identified in the ME group. Different types of manometry methods can be applied to the normal rat colon, but the colonic anastomotic bursting pressure test using the experimental animal hollow organ mechanical testing system is superior to traditional methods. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Preliminary Feed Test Algorithm for the Hanford Waste Vitrification Plant product composition control system

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, M.F.; Piepel, G.F.

    1996-03-01

    The Feed Test Algorithm (FTA) will test the acceptability (conformance with requirements) of process batches in the Hanford Waste Vitrification Plant (HWVP). Although requirements and constraints will be imposed on properties of the material in the melter and the resulting glass, the FTA must test acceptability while the batch is still in the Slurry Mix Evaporator (SME), i.e., before material is transferred to the Melter Feed Tank. Hence, some properties upon which requirements will be imposed must be estimated from data available on the feed slurry. The major type of data to be used in this estimation is feed composition, usually expressed in terms of nine oxide mass fractions and a catchall tenth category, Others. Uncertainties are inherent in the HWVP process. The two major or types of uncertainty are composition uncertainty (that related to measurement and estimation of feed composition and other quantities) and model uncertainty (uncertainty inherent in the models developed to relate melt/glass properties to feed composition). Types of uncertainties, representation of uncertainty, and a method for combining uncertainties are discussed. The FTA must account for these uncertainties in testing acceptability; hence it must be statistical in nature. Three types of statistical intervals (confidence, prediction, and tolerance) are defined, and their roles in acceptance testing are discussed.

  14. Autologous serum skin test reactivity and basophil histamine release test in patients with nasal polyposis: preliminary results.

    Science.gov (United States)

    Zambetti, G; Ciofalo, A; Soldo, P; Fusconi, M; Romeo, R; Greco, A; Altissimi, G; Macri, G F; Marinelli, C; Pagliuca, G; De Vincentiis, M

    2010-01-01

    An eosinophilic inflammatory process is generally observed in patients suffering from nasal polyposis (NP), however its onset has not yet been defined. It has been suggested that immune activation of inflammatory cells may be the cause. The aim of this study is to verify whether autoantibodies and/or histamine-releasing factors are present in the serum of patients suffering from NP. In fact, we assume that autoantibodies and/or histamine-releasing factors, as already demonstrated in chronic idiopathic urticaria and asthma, may be involved in the pathogenesis of NP. In this case-control analytical study 40 patients with NP and 27 control subjects underwent the in vivo autologous serum skin test (ASST). The sera from 6 patients suffering from NP and 9 control group subjects, who had all been previously studied and randomly selected, underwent basophil histamine release assay from normal donor as a pilot study. The ASST showed positive results in 55% of patients suffering from NP versus 8% of the control group (p= .00006), the basophil histamine release test (BHRT) turned out positive in all patients tested and in 11% of the control group. We found a weak positive correlation between the percentage of histamine release and the wheal diameter. ASST reactivity is very frequent in patients suffering from NP, thus suggesting the presence of histamine-releasing factors in the blood stream. The BHRT was positive in the serum of all patients, thus suggesting the presence of anti-FcepsilonRI, anti-IgE autoantibodies and/or other histamine-releasing factors, the presence of which can play a role in triggering and maintaining the eosinophilic inflammatory process in NP.

  15. Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-28

    The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

  16. Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-28

    The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested amethod using commercial sorbents containing Aliquat® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

  17. PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    Yao, C.-Y.; Morrison, L.; Sun, X.; Wang, J.; Cours, A.; Westferro, F.; Xiao, A.; Clute, T.; Conway, Z.; Decker, G.; Lenkszus, F.; Carwardine, J.; Barcikowski, A.; Keane, R.; Brill, A.

    2017-06-25

    The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge, TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.

  18. Experimental comparison of different oscillation-based test techniques in an analog block

    Science.gov (United States)

    Suenaga, Kay; Picos, Rodrigo; Bota, Sebastia; Roca, Miquel; Garcia-Moreno, Eugeni

    2005-06-01

    This paper experimentally analyses the capabilities of an Oscillation-Based Test technique for diagnosis purposes. To evaluate the feasibility of this test strategy, the technique is applied to an Operational Transconductance Amplifier with fault injection capabilities. The application of this methodology has low impact on circuit performances. Voltage and current magnitude have been considered as test observables. The effects of catastrophic and parametric defects (bridges, opens and shorts) are analyzed in this work. Results show that by a right choice of the test observable, this technique provides high fault coverage levels even in the case of process variations.

  19. Development and flight test of an experimental maneuver autopilot for a highly maneuverable aircraft

    Science.gov (United States)

    Duke, Eugene L.; Jones, Frank P.; Roncoli, Ralph B.

    1986-01-01

    This report presents the development of an experimental flight test maneuver autopilot (FTMAP) for a highly maneuverable aircraft. The essence of this technique is the application of an autopilot to provide precise control during required flight test maneuvers. This newly developed flight test technique is being applied at the Dryden Flight Research Facility of NASA Ames Research Center. The FTMAP is designed to increase the quantity and quality of data obtained in test flight. The technique was developed and demonstrated on the highly maneuverable aircraft technology (HiMAT) vehicle. This report describes the HiMAT vehicle systems, maneuver requirements, FTMAP development process, and flight results.

  20. In Vitro Experimental Testing of the Human Knee: A Concise Review.

    Science.gov (United States)

    Maletsky, Lorin; Shalhoub, Sami; Fitzwater, Fallon; Eboch, William; Dickinson, Matthew; Akhbari, Bardiya; Louie, Ednah

    2016-02-01

    In vitro testing of the human knee provides valuable insight that contributes to further understanding knee biomechanics. Cadaveric testing correlates well with clinical trials because the tissue has similar properties to that of live subjects. In addition, in vitro testing allows studies to be performed that would otherwise be unethical to evaluate in vivo. Due to their many advantages, cadaveric testing has been utilized to evaluate many of medical devices and surgical techniques that have been developed in recent decades. This article aims to review the current technologies and methodologies utilized in experimental in vitro testing of the human knee. The article provides a summary of the different rigs and machines that are currently used to examine the biomechanics of the knee. It also highlights the variable experimental techniques and measurement systems that are used to collect the kinematics and kinetics of the knee joint. As technologies advance so do the measurement systems and equipment in the experimental biomechanics field. The influence of improvements to these testing equipment and measurement devices on in vitro testing of the knee will also be discussed in this review. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Preliminary laboratory testing on the sound absorption of coupled cavity sonic crystal

    Science.gov (United States)

    Kristiani, R.; Yahya, I.; Harjana; Suparmi

    2016-11-01

    This paper focuses on the sound absorption performance of coupled cavity sonic crystal. It constructed by a pair of a cylindrical tube with different values in diameters. A laboratory test procedure after ASTM E1050 has been conducted to measure the sound absorption of the sonic crystal elements. The test procedures were implemented to a single coupled scatterer and also to a pair of similar structure. The results showed that using the paired structure bring a better possibility for increase the sound absorption to a wider absorption range. It also bring a practical advantage for setting the local Helmholtz resonant frequency to certain intended frequency.

  2. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Tsuji, Kouichi; Fernández-Ruiz, Ramón; Margui, Eva; Streli, Christina; Pepponi, Giancarlo; Stosnach, Hagen; Yamada, Takashi; Vandenabeele, Peter; Maina, David M.; Gatari, Michael; Shepherd, Keith D.; Towett, Erick K.; Bennun, Leonardo; Custo, Graciela; Vasquez, Cristina; Depero, Laura E.

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique.

  3. Evaluation of experimental factors that influence the application and discrimination capability of the product consistency test

    Energy Technology Data Exchange (ETDEWEB)

    Shade, J.W.; Piepel, G.F.

    1991-06-01

    It is desirable to have a means of monitoring possible changes in waste glass durability during protection so that the product remains within acceptable limits. A leach test called the Product Consistency test (PCT) was developed by Savannah River Laboratory (SRL) as such a production test for the Defense Waste Processing Facility (DWPF). This report examines some of the experimental factors that may be used in the PCT that could influence test precision and its ability to function as intended. An experiment was performed to investigate the effects (on pH and elemental releases of Al, Fe, K, Na, Si, B, Li, and Mn) of modifications to the test conditions of the Product Consistency Test (PCT). The experiment was replicated three times; each replicate involved leach testing two glasses with each of 24 different sets of PCT conditions. 6 refs., 1 fig., 12 tabs.

  4. High Temperature Test Facility Preliminary RELAP5-3D Input Model Description

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, Paul David [Idaho National Laboratory

    2015-12-01

    A RELAP5-3D input model is being developed for the High Temperature Test Facility at Oregon State University. The current model is described in detail. Further refinements will be made to the model as final as-built drawings are released and when system characterization data are available for benchmarking the input model.

  5. High Temperature Steam Electrolysis Materials Degradation: Preliminary Results of Corrosion Tests on Ceramatec Electrolysis Cell Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul Demkowicz; Prateek Sachdev; Kevin DeWall; Pavel Medvedev

    2007-06-01

    Corrosion tests were performed on stainless steel and nickel alloy coupons in H2O/H2 mixtures and dry air to simulate conditions experienced in high temperature steam electrolysis systems. The stainless steel coupons were tested bare and with one of three different proprietary coatings applied. Specimens were corroded at 850°C for 500 h with weight gain data recorded at periodic intervals. Post-test characterization of the samples included surface and cross-section scanning electron microscopy, grazing incidence x-ray diffraction, and area-specific resistance measurements. The uncoated nickel alloy outperformed the ferritic stainless steel under all test conditions based on weight gain data. Parabolic rate constants for corrosion of these two uncoated alloys were consistent with values presented in the literature under similar conditions. The steel coatings reduced corrosion rates in H2O/H2 mixtures by as much as 50% compared to the untreated steel, but in most cases showed negligible corrosion improvement in air. The use of a rare-earth-based coating on stainless steel did not result in a significantly different area specific resistance values after corrosion compared to the untreated alloy. Characterization of the samples is still in progress and the findings will be revised when the complete data set is available.

  6. Preliminary report on engineering geology of thirteen tunnel sites, Nevada Test Site

    Science.gov (United States)

    Wilmarth, Verl Richard; McKeown, Francis Alexander; Dobrovolny, Ernest

    1958-01-01

    Reconnaissance of 13 areas in and adjacent to Nevada Test Site was completed. Of the 13 areas, Forty Mile Canyon, South-central Shoshone Mountain, and Southeast Shoshone Mountain named in order of preference, offer many advantages for carrying on future underground nuclear explosions.

  7. Experimental testing procedures and dynamic model validation for vanadium redox flow battery storage system

    Science.gov (United States)

    Baccino, Francesco; Marinelli, Mattia; Nørgård, Per; Silvestro, Federico

    2014-05-01

    The paper aims at characterizing the electrochemical and thermal parameters of a 15 kW/320 kWh vanadium redox flow battery (VRB) installed in the SYSLAB test facility of the DTU Risø Campus and experimentally validating the proposed dynamic model realized in Matlab-Simulink. The adopted testing procedure consists of analyzing the voltage and current values during a power reference step-response and evaluating the relevant electrochemical parameters such as the internal resistance. The results of different tests are presented and used to define the electrical characteristics and the overall efficiency of the battery system. The test procedure has general validity and could also be used for other storage technologies. The storage model proposed and described is suitable for electrical studies and can represent a general model in terms of validity. Finally, the model simulation outputs are compared with experimental measurements during a discharge-charge sequence.

  8. Optimization Design of a Double-Channel Pump by Means of Orthogonal Test, CFD, and Experimental Analysis

    Directory of Open Access Journals (Sweden)

    Binjuan Zhao

    2014-07-01

    Full Text Available A new approach to optimizing a double-channel pump was presented, based on combined use of orthogonal test, computational fluid dynamics (CFD, and experimental analysis. First, a preliminary pump was designed according to design specifications, implementing the traditional design method. Later, a standard L9 (34 orthogonal table including 9 representative design schemes was implemented to find the best parameter combination for the impeller of the pump. Reynolds averaged Navier-Stokes equations accompanied by Smith modified k-ε turbulence model were solved to obtain the inner flow fields of the pump as well as its hydraulic performance for each design scheme. The optimized design scheme was obtained after range analysis. Finally, CFD analyses and experiments were carried out to evaluate the optimized design. The results show that the characteristics of the optimized pump were obviously improved, and the simulated pump head and efficiency increased by 3.622% and 9.379%, respectively. This research not only provides an effective way to improve the hydraulic design of double-channel pumps, but also has certain reference value in multiobjectiveoptimization design of other pumps.

  9. Experimental Tests of the Astrometric Precision Obtainable with a Ten Micron Interferometer.

    Science.gov (United States)

    1982-01-18

    declination-dependent phase offset is caused by the failure of the axes of rotation of the heliostat mirrors to intersect precisely . The source...A-Ji>L __ _ _ _ _ _ 4. TITLE (and Subtitle) S. TYPE Of REPORT & PERIOD COVERED EXPERIMENTAL TESTS OF THE ASTROMETRIC PRECISION Final Contract...of tests successfully achieved its objective and demonstrated the usefulness of infrared spatial interferometry for very precise astrometric

  10. Preliminary results on performance testing of a turbocharged rotary combustion engine

    Science.gov (United States)

    Meng, P. R.; Rice, W. J.; Schock, H. J.; Pringle, D. P.

    1982-01-01

    The performance of a turbocharged rotary engine at power levels above 75 kW (100 hp) was studied. A twin rotor turbocharged Mazda engine was tested at speeds of 3000 to 6000 rpm and boost pressures to 7 psi. The NASA developed combustion diagnostic instrumentation was used to quantify indicated and pumping mean effect pressures, peak pressure, and face to face variability on a cycle by cycle basis. Results of this testing showed that a 5900 rpm a 36 percent increase in power was obtained by operating the engine in the turbocharged configuration. When operating with lean carburetor jets at 105 hp (78.3 kW) and 4000 rpm, a brake specific fuel consumption of 0.45 lbm/lb-hr was measured.

  11. Numerical and experimental direct shear tests for coarse-grained soils

    Institute of Scientific and Technical Information of China (English)

    Ahad Bagherzadeh-Khalkhali; Ali Asghar Mirghasemi

    2009-01-01

    The presence of particles larger than the permissible dimensions of conventional laboratory specimens causes difficulty in the determination of shear strength of coarse-grained soils. In this research, the influence of particle size on shear strength of coarse-grained soils was investigated by resorting to experimental tests in different scale and numerical simulations based on discrete element method (DEM). Experimental tests on such soil specimens were based on using the techniques designated as "parallel" and "scalping" to prepare gradation of samples in view of the limitation of laboratory specimen size. As a second approach, the direct shear test was numerically simulated on assemblies of elliptical particles. The behaviors of samples under experimental and numerical tests are presented and compared, indicating that the modification of sample gradation has a significant influence on the mechanical properties of coarse-grained soils. It is noted that the shear strengths of samples produced by the scalping method are higher than samples by the parallel method. The scalping method for preparing specimens for direct shear test is therefore recommended. The micromechanical behavior of assemblies under direct shear test is also discussed and the effects of stress level on sample behavior are investigated.

  12. F-111 Adhesively Bonded Repair Assessment Program (FABRAP) - Phase 1 Testing, Preliminary Results

    Science.gov (United States)

    2011-08-01

    UNCLASSIFIED 4 UNCLASSIFED DSTO-TN-1024  aircraft that have been reserved for other use such as museum displays. Negotiations are underway to test...additional hazards when used outside of a fume cupboard/booth. Citrasafe is a non-toxic low volatile plant extract solvent which has been shown to be...work during hayfever seasons may expose workers to pollen allergens. Staff with known allergies will be advised to prepare by using

  13. Mastitis diagnosis in dairy goats through somatic cell counts and California mastitis test. Preliminary results

    OpenAIRE

    Mendonça, Álvaro; Valentim, Ramiro; Nunes, Manuel; Correia, Teresa Montenegro; Trigo, Margarida; Maurício, Raimundo; Costa, Cristina; Coelho, Alípio

    2004-01-01

    The aim of this work was to evaluate somatic cell count (SCC) and Californian mastitis test (CMT) reliability as methods to survey mastitis in Serrana goats. Microbiological diagnosis, SCC and CTM were performed on 2028 samples, collected from individual glands during a lactation period. According to results CMT (predictive negative value = 69.5%) may be used as a cheap and practical method for sub clinical mastitis survey in Serrana goats. Decision on SCC use will depend on additional resear...

  14. [Preliminary Study on Error Control of Medical Devices Test Reports Based on the Analytic Hierarchy Process].

    Science.gov (United States)

    Huang, Yanhong; Xu, Honglei; Tu, Rong; Zhang, Xu; Huang, Min

    2016-01-01

    In this paper, the common errors in medical devices test reports are classified and analyzed. And then the main 11 influence factors for these inspection report errors are summarized. The hierarchy model was also developed and verified by presentation data using MATLAB. The feasibility of comprehensive weights quantitative comparison has been analyzed by using the analytic hierarchy process. In the end, this paper porspects the further research direction.

  15. Commissioning of the STAR test section for experimental simulation of loss of coolant accident using the EC-208 instrumented fuel assembly of the IEA-R1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maprelian, Eduardo; Torres, Walmir M.; Prado, Adelk C.; Umbehaun, Pedro E.; Franca, Renato L.; Santos, Samuel C.; Macedo, Luiz A.; Sabundjian, Gaiane, E-mail: emaprel@ipen.br, E-mail: wmtorres@ipen.br, E-mail: acprado@ipen.br, E-mail: umbehaun@ipen.br, E-mail: rlfranca@ipen.br, E-mail: samuelcs@ipen.br, E-mail: lamacedo@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SO (Brazil)

    2015-07-01

    The three basic safety functions of Research Reactors (RR) are the safe shutdown of the reactor, the proper cooling of the decay heat of the fuel elements and the confinement of radioactive materials. Compared to Nuclear Power Reactors, RR power release is small, yet its three safety functions must be met to ensure the integrity of the reactor. During a loss of coolant accident (LOCA) in pool type RR, partial or complete loss of pool water may occur, with consequent partial or complete uncovering of the fuel assemblies. In such an accident, the decay heat removal safety function must not be compromised. The Test Section for Experimental Simulation of Loss of Coolant Accident (STAR) is in commissioning phase. This test section will provide experimental data on partial and total uncovering of the EC-208 instrumented fuel assembly (IFA) irradiated in the IEA-R1. Experimental results will be useful in validation of computer codes for RR safety analysis, particularly on heat removal efficiency aspects (safety function) in accident conditions. STAR comprises a base on which is installed the IFA, the cylindrical stainless steel hull, the compressed air system for the test section emptying and refilling, and the instrumentation for temperature and level measurements. The commissioning tests or pre-operational check, consist of several preliminary tests to verify experimental procedures, the difficulties during assembling of STAR in the pool, the difficulties in control the emptying and refilling velocities, as well as, the repeatability capacity, tests of equipment, valves and systems and tests of instrumentation and data acquisition system. Safety, accuracy and easiness of operation will be checked. (author)

  16. New method for rapid Susceptibility Testing on blood culture with HB&L system: preliminary data

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2010-12-01

    Full Text Available Blood culture, although represents the gold standard in detecting the ethiological agent of sepsis, is rather rarely required in relation to the real diagnostic importance. The result of this test depends in fact on many factors (sample volume, time of collection, accuracy, antibiotic therapy, contamination, number of drawings, drawing site, interpretation difficulties, etc. that are often considered by many clinicians so limited as to doubt about their actual value. The disadvantages are therefore represented by the lack of standardization but also by the low sensitivity and above all by the technical times too long for the clinical needs. Blood culture begins with the drawing of samples from the “septic” patient followed incubation of the bottles in automatic thermostated systems. In case of positive result (36 hours, the culture is Gram stained and streaked on solid media in order to obtain isolated colonies for the identification and the susceptibility testing (48 hours from positive result. The long time required for pathogen identification and susceptibility testing involves empirical broad spectrum antibiotic therapy that can promote the increase of bacterial resistance but also patient management costs. A clinically useful report should be available on short notice in order to guide the clinician to choose the most appropriate antibiotic. The microbiologist has therefore the hard work of reviewing the organization and the management of the procedures.We have therefore started to consider the possibility of treating the blood as an biological liquid in order to quickly determine the susceptibility of bacteria to antibiotics.

  17. Preliminary Benchmark Evaluation of Japan’s High Temperature Engineering Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    John Darrell Bess

    2009-05-01

    A benchmark model of the initial fully-loaded start-up core critical of Japan’s High Temperature Engineering Test Reactor (HTTR) was developed to provide data in support of ongoing validation efforts of the Very High Temperature Reactor Program using publicly available resources. The HTTR is a 30 MWt test reactor utilizing graphite moderation, helium coolant, and prismatic TRISO fuel. The benchmark was modeled using MCNP5 with various neutron cross-section libraries. An uncertainty evaluation was performed by perturbing the benchmark model and comparing the resultant eigenvalues. The calculated eigenvalues are approximately 2-3% greater than expected with an uncertainty of ±0.70%. The primary sources of uncertainty are the impurities in the core and reflector graphite. The release of additional HTTR data could effectively reduce the benchmark model uncertainties and bias. Sensitivity of the results to the graphite impurity content might imply that further evaluation of the graphite content could significantly improve calculated results. Proper characterization of graphite for future Next Generation Nuclear Power reactor designs will improve computational modeling capabilities. Current benchmarking activities include evaluation of the annular HTTR cores and assessment of the remaining start-up core physics experiments, including reactivity effects, reactivity coefficient, and reaction-rate distribution measurements. Long term benchmarking goals might include analyses of the hot zero-power critical, rise-to-power tests, and other irradiation, safety, and technical evaluations performed with the HTTR.

  18. Preliminary study of Internet addiction and cognitive function in adolescents based on IQ tests.

    Science.gov (United States)

    Park, Min-Hyeon; Park, E-Jin; Choi, Jeewook; Chai, Sukhi; Lee, Ji-Han; Lee, Chul; Kim, Dai-Jin

    2011-12-30

    The potential relationship between Internet addiction and certain cognitive function problems has been suggested by several studies. However, few or no studies have examined the differences in cognitive functioning between persons addicted to the Internet and persons not addicted using a standard neuropsychological test. This study screened 253 middle school students and 389 high school students for Internet addiction and compared 59 Internet-addicted students with 43 non-addicted students using an IQ test. The Internet-addicted group had comprehension sub-item scores that were significantly lower than those of the non-addicted group. As the comprehension item reflects ethical judgement and reality testing, there may be a relationship between Internet addiction and weak social intelligence. Earlier onset of Internet addiction and longer addiction duration were associated with lower participant performance in areas related to attention. As this study is a cross-sectional study, it is not clear whether the persons who display weak cognitive functioning are susceptible to Internet addiction or if Internet addiction causes cognitive problems. However, as brain development remains active during adolescence, the possibility that Internet addiction adversely affects the cognitive functioning of adolescents cannot be ruled out.

  19. Establishment and Preliminary Application of a Rapid Fluorescent Focus Inhibition Test (RFFIT) for Rabies Virus

    Institute of Scientific and Technical Information of China (English)

    Pengcheng Yu; Xinjun Lv; Xinxin Shen; Qing Tang; Guodong Liang

    2013-01-01

    The World Health Organization (WHO) standard assay for determining levels of the rabies virus neutralization antibody (RVNA) is the rapid fluorescent focus inhibition test (RFFIT),which is used to evaluate the immunity effect after vaccination against rabies.For RFFIT,CVS-11 was used as the challenge virus,BSR cells as the adapted cells,and WHO rabies immunoglobulin (WHO STD) as the reference serum in this study.With reference to WHO and Pasteur RFFIT procedures,a micro-RFFIT procedure adapted to our laboratory was produced,and its specificity and reproducibility were tested.We tested levels of RVNA in human serum samples after immunization with different human rabies vaccines (domestic purified Vero cell rabies vaccine (PVRV) and imported purified chick embryo cell vaccine (PCECV)) using different regimens (Zagreb regimen and Essen regimen).We analyzed the levels of RVNA,and compared the immune efficacy of domestic PVRV and imported PCECV using different immunization regimens.The results showed that the immune efficacy of domestic PVRV using the Zagreb regimen was as good as that of the imported PCECV,but virus antibodies were generated more rapidly with the Zagreb regimen than with the Essen regimen.The RFFIT procedure established in our laboratory will enhance the comprehensive detection ability of institutions involved in rabies surveillance in China.

  20. New sonographically-guided test for anterior knee instability – preliminary report

    Directory of Open Access Journals (Sweden)

    Piotr Grzelak

    2014-09-01

    Full Text Available Aim of the study: Ultrasound examination is widely used in orthopedic diagnostics, however sonographic evaluation of traumatic anterior cruciate ligament insufficiency is still inadequate. Aim of this study is to evaluate diagnostic capability of a new sonographicallyguided test for diagnosing complete anterior cruciate ligament insufficiency. Material and methods: In 47 patients, with suspicion of unilateral anterior cruciate ligament injury (based on magnetic resonance imaging, the sonographically-guided test for anterior instability was performed. The translation of the intercondylar eminence against the patellar tendon was measured in both knees. Afterwards all patients underwent arthroscopy. Results: In 37 patients, with arthroscopically confirmed complete anterior cruciate ligament insufficiency, the mean anterior knee translation was 8.3 mm (SD = 2.8 in affected knee vs. 3 mm (SD = 1.1 in uninjured knee (p < 0.001. In 10 patients with no anterior cruciate ligament insufficiency the difference between body sides was not significant (2.6 mm, SD = 1.4 in injured knee vs. 2.5 mm, SD = 1.1 in uninjured joint; p < 0.7753. Conclusions: The proposed test supports the clinician with fast and noninvasive examination that can facilitate evaluation of anterior knee instability.

  1. Preliminary chemical analysis and biological testing of materials from the HRI catalytic two-stage liquefaction (CTSL) process. [Aliphatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Later, D.W.; Wilson, B.W.

    1985-01-01

    Coal-derived materials from experimental runs of Hydrocarbon Research Incorporated's (HRI) catalytic two-stage liquefaction (CTSL) process were chemically characterized and screened for microbial mutagenicity. This process differs from two-stage coal liquefaction processes in that catalyst is used in both stages. Samples from both the first and second stages were class-fractionated by alumina adsorption chromatography. The fractions were analyzed by capillary column gas chromatography; gas chromatography/mass spectrometry; direct probe, low voltage mass spectrometry; and proton nuclear magnetic resonance spectrometry. Mutagenicity assays were performed with the crude and class fractions in Salmonella typhimurium, TA98. Preliminary results of chemical analyses indicate that >80% CTSL materials from both process stages were aliphatic hydrocarbon and polynuclear aromatic hydrocarbon (PAH) compounds. Furthermore, the gross and specific chemical composition of process materials from the first stage were very similar to those of the second stage. In general, the unfractionated materials were only slightly active in the TA98 mutagenicity assay. Like other coal liquefaction materials investigated in this laboratory, the nitrogen-containing polycyclic aromatic compound (N-PAC) class fractions were responsible for the bulk of the mutagenic activity of the crudes. Finally, it was shown that this activity correlated with the presence of amino-PAH. 20 figures, 9 tables.

  2. Dy-IP characterization and its application for experimental neutron radiography tests under realistic conditions

    Science.gov (United States)

    Tamaki, Masayoshi; Iida, Kazuhiro; Mori, Noriaki; Lehmann, Eberhard H.; Vontobel, Peter; Estermann, Mirko

    2005-04-01

    Imaging plates containing Dy for neutron radiography have been designed, fabricated and tested experimentally. Using the imaging plates combined with the developed NR system and the honeycomb collimator, quantitative neutron radiograph, which is free from scattered neutron and γ-ray, has been obtained. Application has been conducted for the post-irradiation examination for the nuclear fuel pin.

  3. State-independent experimental test of quantum contextuality in an indivisible system.

    Science.gov (United States)

    Zu, C; Wang, Y-X; Deng, D-L; Chang, X-Y; Liu, K; Hou, P-Y; Yang, H-X; Duan, L-M

    2012-10-12

    We report the first state-independent experimental test of quantum contextuality on a single photonic qutrit (three-dimensional system), based on a recent theoretical proposal [Phys. Rev. Lett. 108, 030402 (2012)]. Our experiment spotlights quantum contextuality in its most basic form, in a way that is independent of either the state or the tensor product structure of the system.

  4. 78 FR 41129 - Market Test of Experimental Product - International Merchandise Return Service-Non-Published Rates

    Science.gov (United States)

    2013-07-09

    ... of Experimental Product -- International Merchandise Return Service--Non-Published Rates AGENCY: U.S... International Merchandise Return Service--Non-Published Rates in accordance with statutory requirements. DATES... will begin a market test of its International Merchandise Return Service (IMRS) Non-published Rate...

  5. Experimental test of error-disturbance uncertainty relations by weak measurement.

    Science.gov (United States)

    Kaneda, Fumihiro; Baek, So-Young; Ozawa, Masanao; Edamatsu, Keiichi

    2014-01-17

    We experimentally test the error-disturbance uncertainty relation (EDR) in generalized, strength-variable measurement of a single photon polarization qubit, making use of weak measurement that keeps the initial signal state practically unchanged. We demonstrate that the Heisenberg EDR is violated, yet the Ozawa and Branciard EDRs are valid throughout the range of our measurement strength.

  6. Tableau tool for testing satisfiability in LTL: Implementation and experimental analysis

    DEFF Research Database (Denmark)

    Goranko, Valentin; Kyrilov, Angelo; Shkatov, Dmitry

    2010-01-01

    We report on the implementation and experimental analysis of an incremental multi-pass tableau-based procedure `a la Wolper for testing satisfiability in the linear time temporal logic LTL, based on a breadthfirst search strategy. We describe the implementation and discuss the performance of the ...

  7. Experimental Aeroelastic Models Design and Wind Tunnel Testing for Correlation with New Theory

    Directory of Open Access Journals (Sweden)

    2016-04-01

    Full Text Available Several examples of experimental model designs, wind tunnel tests and correlation with new theory are presented in this paper. The goal is not only to evaluate a new theory, new computational method or new aeroelastic phonomenon, but also to provide new insights into nonlinear aeroelastic phenomena, flutter, limit cycle oscillation (LCO and gust response.

  8. Testing the theory of emissions trading : Experimental evidence on alternative mechanisms for global carbon trading

    NARCIS (Netherlands)

    Klaassen, Ger; Nentjes, Andries; Smith, Mark

    2005-01-01

    Simulation models and theory prove that emission trading converges to market equilibrium. This paper sets out to test these results using experimental economics. Three experiments are conducted for the six largest carbon emitting industrialized regions. Two experiments use auctions, the first a

  9. Predicting the Grouting Ability of Sandy Soils by Artificial Neural Networks Based On Experimental Tests

    Directory of Open Access Journals (Sweden)

    Mahmoud Hassanlourad

    2014-12-01

    Full Text Available In this paper, the grouting ability of sandy soils is investigated by artificial neural networks based on the results of chemical grout injection tests. In order to evaluate the soil grouting potential, experimental samples were prepared and then injected. The sand samples with three different particle sizes (medium, fine, and silty and three relative densities (%30, %50, and %90 were injected with the sodium silicate grout with three different concentrations (water to sodium silicate ratio of 0.33, 1, and 2. A multi-layer Perceptron type of the artificial neural network was trained and tested using the results of 138 experimental tests. The multi-layer Perceptron included one input layer, two hidden layers and one output layer. The input parameters consisted of initial relative densities of grouted samples, the average size of particles (D50, the ratio of the grout water to sodium silicate and the grout pressure. The output parameter was the grout injection radius. The results of the experimental tests showed that the radius of grout injection is a complicated function of the mentioned parameters. In addition, the results of the trained artificial neural network showed to be reasonably consistent with the experimental results.

  10. Does assessment of personal exposure matter during experimental neurocognitive testing in MRI-related magnetic fields?

    NARCIS (Netherlands)

    van Nierop, Lotte E; Christopher-de Vries, Y.; Slottje, Pauline; Kromhout, Hans

    2015-01-01

    PURPOSE: To determine whether the use of quantitative personal exposure measurements in experimental research would result in better estimates of the associations between static and time-varying magnetic field exposure and neurocognitive test performance than when exposure categories were based sole

  11. Validation of a Wave-Body Interaction Model by Experimental Tests

    DEFF Research Database (Denmark)

    Ferri, Francesco; Kramer, Morten; Pecher, Arthur

    2013-01-01

    Within the wave energy field, numerical simulation has recently acquired a worldwide consent as being a useful tool, besides physical model testing. The main goal of this work is the validation of a numerical model by experimental results. The numerical model is based on a linear wave-body intera...

  12. Testing the theory of emissions trading : Experimental evidence on alternative mechanisms for global carbon trading

    NARCIS (Netherlands)

    Klaassen, Ger; Nentjes, Andries; Smith, Mark

    2005-01-01

    Simulation models and theory prove that emission trading converges to market equilibrium. This paper sets out to test these results using experimental economics. Three experiments are conducted for the six largest carbon emitting industrialized regions. Two experiments use auctions, the first a sing

  13. An Automated, Experimenter-Free Method for the Standardised, Operant Cognitive Testing of Rats

    Science.gov (United States)

    Rivalan, Marion; Munawar, Humaira; Fuchs, Anna; Winter, York

    2017-01-01

    Animal models of human pathology are essential for biomedical research. However, a recurring issue in the use of animal models is the poor reproducibility of behavioural and physiological findings within and between laboratories. The most critical factor influencing this issue remains the experimenter themselves. One solution is the use of procedures devoid of human intervention. We present a novel approach to experimenter-free testing cognitive abilities in rats, by combining undisturbed group housing with automated, standardized and individual operant testing. This experimenter-free system consisted of an automated-operant system (Bussey-Saksida rat touch screen) connected to a home cage containing group living rats via an automated animal sorter (PhenoSys). The automated animal sorter, which is based on radio-frequency identification (RFID) technology, functioned as a mechanical replacement of the experimenter. Rats learnt to regularly and individually enter the operant chamber and remained there for the duration of the experimental session only. Self-motivated rats acquired the complex touch screen task of trial-unique non-matching to location (TUNL) in half the time reported for animals that were manually placed into the operant chamber. Rat performance was similar between the two groups within our laboratory, and comparable to previously published results obtained elsewhere. This reproducibility, both within and between laboratories, confirms the validity of this approach. In addition, automation reduced daily experimental time by 80%, eliminated animal handling, and reduced equipment cost. This automated, experimenter-free setup is a promising tool of great potential for testing a large variety of functions with full automation in future studies. PMID:28060883

  14. An irradiation test of heat-resistant ceramic composite materials. Interim report on post-irradiation examinations of the first preliminary irradiation test: 97M-13A

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Shin-ichi; Takahashi, Tsuneo; Ishihara, Masahiro; Hayashi, Kimio; Sozawa, Shizuo; Saito, Takashi [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Suzuki, Yoshio [Nuclear Engineering, Co. Ltd., Osaka (Japan); Saito, Tamotsu; Sekino, Hajime [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The Japan Atomic Energy Research Institute (JAERI) has been carrying out the research on radiation damage mechanism of heat-resistant ceramic composite materials, as one of the subjects of the innovative basic research on high temperature engineering using the High Temperature Engineering Test Reactor (HTTR). A series of preliminary irradiation tests is being made using the Japan Materials Testing Reactor (JMTR). The present report describes results of post-irradiation examinations (PIE) so far on specimens irradiated in the first capsule, designated 97M-13A, to fast neutron fluences of 1.2-1.8x10{sup 24} m{sup -2} (E>1 MeV) at temperatures of 573, 673 and 843 K. In the PIE, measurements were made on (1) dimensional changes, (2) thermal expansions, (3) X-ray parameters and (4) {gamma}-ray spectra. The results for the carbon/carbon and SiC/SiC composites were similar to those in existing literatures. The temperature monitor effect was observed both for SiC fiber- and particle-reinforced SiC composites as in the case of monolithic SiC. Namely, the curve of the coefficient of thermal expansion (CTE) of these specimens showed a rapid drop above a temperature around the irradiation temperature +100 K in the first ramp (ramp rate: 10 K/min), while in the second ramp the CTE curves were almost the same as those of un-irradiated SiC specimens. (author)

  15. ENGINEERING DESIGN OPTIMIZATION OF HEEL TESTING EQUIPMENT IN THE EXPERIMENTAL VALIDATION OF SAFE WALKING

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2017-06-01

    Full Text Available Experimental test methods for the evaluation of the resistance of heels of ladies' shoes in the case of impact loads are fully defined by International Organization for Standardization (ISO procedures that indicate all the conditions of experiment. A first Standard (ISO 19553 specifies the test method for determining the strength of the heels in the case of single impact. The result offers a valuation of the liability to fail under the sporadic heavy blows. A second Standard (ISO 19556 details a method for testing the capability of heels of women' shoes to survive to the repetition of small impacts provoked by normal walking. These Standards strictly define the features for two different testing devices (with specific materials, geometries, weights, etc. and all the experimental procedures to be followed during tests. On the contrary, this paper describes the technical solutions adopted to design one single experimental device able to perform impact testing of heels in both conditions. Joining the accuracy of mechanic movements with the speed of an electronic control system, a new and flexible equipment for the complete characterization of heels respect to (single or fatigue impacts was developed. Moreover a new level of performances in experimental validation of heel resistance was introduced by the versatility of the user-defined software control programs, able to encode every complex time-depending cycle of impact loads. Dynamic simulations permitted to investigate the impacts on heel in different conditions of testing, optimizing the machine design. The complexity of real stresses on shoes during an ordinary walk and in other common situations (as going up and downstairs was considered for a proper dimensioning.

  16. Jaw-opening force test to screen for Dysphagia: preliminary results.

    Science.gov (United States)

    Hara, Koji; Tohara, Haruka; Wada, Satoko; Iida, Takatoshi; Ueda, Koichiro; Ansai, Toshihiro

    2014-05-01

    To assess the jaw-opening force test (JOFT) for dysphagia screening. Criterion standard. University dental hospital. Patients complaining of dysphagia (N=95) and with symptoms of dysphagia with chronic underlying causes (mean age ± SD, 79.3±9.61y; range, 50-94y; men: n=49; mean age ± SD, 77.03±9.81y; range, 50-94y; women: n=46; mean age ± SD, 75.42±9.73y; range, 51-93y) admitted for treatment between May 2011 and December 2012 were included. None. All patients were administered the JOFT and underwent fiberoptic endoscopic evaluation of swallowing (FEES). The mean jaw-opening strength was compared with aspiration (ASP) and pharyngeal residue observations of the FEES, which was used as the criterion standard. A receiver operating characteristic (ROC) curve analysis was performed. Forces of ≤3.2kg for men and ≤4kg for women were appropriate cutoff values for predicting ASP with a sensitivity and specificity of .57 and .79 for men and .93 and .52 for women, respectively. Based on the ROC analyses for predicting pharyngeal residue, forces of ≤5.3kg in men and ≤3.9kg in women were appropriate cutoff values, with a sensitivity and specificity of .80 and .88 for men and .83 and .81 for women, respectively. The JOFT could be a useful screening tool for predicting pharyngeal residue and could provide useful information to aid in the referral of patients for further diagnostic imaging testing. However, given its low sensitivity to ASP the JOFT should be paired with other screening tests that predict ASP. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Preliminary Tests of Nose- and Side- Entrance Blower Cooling Systems for Radial Engines, Special Report

    Science.gov (United States)

    Biermann, David; Valentine, E. Floyd

    1939-01-01

    Two cowling systems intended to reduce the drag and improve the low-speed cooling characteristics of conventional radial engine cowlings were tested in model form to determine the practicability of the methods. One cowling included a blower mounted on the rear face of a large propeller spinner which drew cooling air in through side entrance ducts located behind the equivalent engine orifice plate. The air was passed through the equivalent engine orifice plate from rear to front and out through a slot between the spinner and the engine plate. The blower produced substantially all the power necessary to circulate the cooling air in some cases, so the quantity of air flowing was independent of the air speed, Two types of blowers were used, a centrifugal type and one using airfoil blades which forced the air outward from the center of rotation. The other cowling was similar to the conventional N.A.C.A. cowling except for the addition of a large propeller spinner nose. The spinner was provided with a hole in the nose to admit cooling air and blower blades to increase the pressure for cooling at low speeds. The tests show that with both cowling types the basic drag of the nacelle was reduced substantially below that for the N.A.C.A. cowling by virtue of the better nose shape made possible by the spinner . The drag due to the side-entrance ducts was nearly zero when the openings were closed or when the blower was drawing in a certain quantity of air in proportion to the air speed. The drag increased, however, when air mas allowed to spill from the openings. The nose-entrance blower showed considerable promise as a cooling means although the blower tested was relatively inefficient, owing to the fact that the blower compartments evidently were expanded too rapidly under the conditions imposed. by the design.

  18. A preliminary guidebook for identifying stratigraphic contacts at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Pawloski, G.A.; McKague, H.L.; Wagoner, J.L. [Lawrence Livermore National Lab., CA (United States); McKinnis, W.B. [Lawrence Livermore National Lab., Mercury, NV (United States)

    1992-01-01

    Lithologic variation, regional depositional trends, and the lack of written guidelines have resulted in inconsistencies in the recognition of stratigraphic contacts in drill holes at the Nevada Test Site (NTS). Stratigraphic identification, based on mineralogy of discrete samples, can be augmented by geophysical logs and downhole movies to more accurately and consistently locate contacts between units. Criteria are established for locating the base of the Pahute Mesa ash-flow tuff, the top of the Ammonia Tanks ash-flow tuff, the top of the Ammonia Tanks bedded tuff, and the top and the base of the Rainier Mesa Tuff.

  19. Blood splash in lambs-a preliminary study using the one-stage prothrombin time test.

    Science.gov (United States)

    Restall, D J

    1981-02-01

    Lambs from a flock in which a high incidence of blood splash had been detected were examined using the one-stage prothrombin test. For comparison lambs from a commercial slaughter line were also examined. All the affected lambs and 35·4% from the slaughter line had extended prothrombin times, and a relationship between extended prothrombin times and the occurrence of blood splash was established. Investigation of the pastures grazed by the affected flock showed the presence of coumarin producing plants and grasses. Some coumarin drugs prolong one-stage prothrombin times, and more importantly, induce capillary fragility, thus predisposing animals to blood splash.

  20. The Gaia-FUN-SSO observation campaign of 99942 Apophis: A preliminary test for the network

    CERN Document Server

    Bancelin, D; Ivantsov, A; Desmars, J; Assafin, M; Eggl, S; Hestroffer, D; Rocher, P; Carry, B; David, P

    2016-01-01

    In order to test the coordination and evaluate the overall performance of the Gaia-FUN-SSO, an observation campaign on the Potentially Hazardous Asteroid (99 942) Apophis was conducted from 12/21/2012 to 5/2/2013 providing 2732 high quality astrometric observations. We show that a consistent reduction of astrometric campaigns with reliable stellar catalogs substantially improves the quality of astrometric results. We present evidence that the new data will help to reduce the orbit uncertainty of Apophis during its close approach in 2029.

  1. Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

    Science.gov (United States)

    Diskin, Glenn S.; DiGangi, Joshua P.; Yang, Melissa; Slate, Thomas A.; Rana, Mario

    2015-01-01

    Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

  2. Skin Prick Test Analysis in Allergic Rhinitis Patients: A Preliminary Study in Abuja, Nigeria

    Directory of Open Access Journals (Sweden)

    P. U. Ibekwe

    2016-01-01

    Full Text Available Allergic rhinitis (AR is prevalent in Nigeria, though little information exists on the allergen. We assessed the clinical features of AR patients in our environment based on the allergic rhinitis impact on asthma (ARIA classification. Only patients with positive skin prick test (SPT were recruited. Seventy-four patients participated in the study. AR and asthma comorbidity were observed in 13.5%. The proportion of “sneezers-runners” was higher than “blockers” with significantly more “sneezers-runners” having persistent AR (P=0.007. No relationship was established between these predominant symptoms and the aeroallergens used in this study. Intermittent mild and moderate/severe AR were evident in 13.5% and 31.1%, while persistent mild and moderate/severe were seen in 20.3% and 35.1%, respectively. House dust mites allergen yielded the highest number of positive responses (22.6% followed by tree pollen (16.8%. No relationship was observed between the allergens tested and AR severity. Majority of patients were oligosensitive (33.8% and polysensitive (35.1% and were not significantly associated with AR severity (P=0.07. Most AR patients presenting for treatment in Abuja, Nigeria, had moderate-severe persistent AR and showed similar SPT sensitization pattern with countries having similar climatic conditions. Sensitization patterns were not related to ARIA classification or predominant AR symptoms.

  3. Word memory test performance in Canadian adolescents with learning disabilities: a preliminary study.

    Science.gov (United States)

    Larochette, Anne-Claire; Harrison, Allyson G

    2012-01-01

    The purpose of this study was to evaluate Word Memory Test (WMT) performances in students with identified learning disabilities (LDs) providing good effort to examine the influence of severe reading or learning problems on WMT performance. Participants were 63 students with LDs aged 11 to 14 years old (M = 12.19 years), who completed psychoeducational assessments as part of a transition program to secondary school. Participants were administered a battery of psychodiagnostic tests including the WMT. Results indicated that 9.5% of students with LD met Criterion A on the WMT (i.e., perform below cut-offs on any of the first three subtests of the WMT), but less than 1% met both criteria necessary for identification of low effort. Failure on the first three subtests of the WMT was associated with word reading at or below the 1st percentile and severely impaired phonetic decoding and phonological awareness skills. These results indicate that the majority of students with a history of LD are capable of passing the WMT, and use of profile analysis reduces the false-positive rate to below 1%.

  4. A Structured Clinical Interview for Kleptomania (SCI-K): preliminary validity and reliability testing.

    Science.gov (United States)

    Grant, Jon E; Kim, Suck Won; McCabe, James S

    2006-06-01

    Kleptomania presents difficulties in diagnosis for clinicians. This study aimed to develop and test a DSM-IV-based diagnostic instrument for kleptomania. To assess for current kleptomania the Structured Clinical Interview for Kleptomania (SCI-K) was administered to 112 consecutive subjects requesting psychiatric outpatient treatment for a variety of disorders. Reliability and validity were determined. Classification accuracy was examined using the longitudinal course of illness. The SCI-K demonstrated excellent test-retest (Phi coefficient = 0.956 (95% CI = 0.937, 0.970)) and inter-rater reliability (phi coefficient = 0.718 (95% CI = 0.506, 0.848)) in the diagnosis of kleptomania. Concurrent validity was observed with a self-report measure using DSM-IV kleptomania criteria (phi coefficient = 0.769 (95% CI = 0.653, 0.850)). Discriminant validity was observed with a measure of depression (point biserial coefficient = -0.020 (95% CI = -0.205, 0.166)). The SCI-K demonstrated both high sensitivity and specificity based on longitudinal assessment. The SCI-K demonstrated excellent reliability and validity in diagnosing kleptomania in subjects presenting with various psychiatric problems. These findings require replication in larger groups, including non-psychiatric populations, to examine their generalizability. Copyright (c) 2006 John Wiley & Sons, Ltd.

  5. Clinical utility of the Multiple Errands Test in schizophrenia: A preliminary assessment.

    Science.gov (United States)

    Bulzacka, Ewa; Delourme, Gwenaëlle; Hutin, Valérie; Burban, Nathalie; Méary, Alexandre; Lajnef, Mohamed; Leboyer, Marion; Schürhoff, Franck

    2016-06-30

    Schizophrenia (SZ) is a chronic, severe disease, which results in misperception of reality, major social withdrawal, and cognitive disturbances. One type of cognitive disturbance, known as executive dysfunction, is widely considered as a primary determinant of functional outcome. However, classic neuropsychological measures of executive functioning (EF) poorly represent patients' functional outcome, and thus seem inappropriate for evaluating the real-world functional impact of diseases such as SZ. We hypothesized that the Multiple Errands Test (MET), an ecological assessment of executive function would show greater ability to measure everyday adaptive functioning SZ, compared to conventional EF assessment methods. 100 clinically stable SZ patients were administered the MET, Wisconsin Card Sorting Test - 64 and a paper version of MET. Correlation analyses were performed between each EF measure and functional outcome, as measured by the Social Autonomy Scale (SAS). After adjusting for age, education, IQ and illness duration, SAS was significantly predicted by MET global score. No other EF measure correlated with SAS. Results from this study suggest that MET offers a valuable prediction of daily life functional outcome in this large sample of SZ patients. Therefore, it could be used as a complementary measure to improve the identification of executive dysfunctions prior to psychosocial interventions.

  6. Qualification of the radiation environment in the TCC2 experimental test area.

    CERN Document Server

    Fynbo, C A

    2000-01-01

    This report qualifies the radiation environment to be found in the area behind the beam dump in the TCC2 experimental hall where tests are being performed on the radiation hardness and sensitivity to Single Event Upsets of electronics to be installed near the LHC machine. A comparison is made with the radiation environment expected for the LHC, and we conclude that the environment found in the test area matches that of LHC such that tests performed here will provide a valid simulation of electronics performance under LHC running conditions.

  7. Experimental and numerical study of drill bit drop tests on Kuru granite

    Science.gov (United States)

    Fourmeau, Marion; Kane, Alexandre; Hokka, Mikko

    2017-01-01

    This paper presents an experimental and numerical study of Kuru grey granite impacted with a seven-buttons drill bit mounted on an instrumented drop test machine. The force versus displacement curves during the impact, so-called bit-rock interaction (BRI) curves, were obtained using strain gauge measurements for two levels of impact energy. Moreover, the volume of removed rock after each drop test was evaluated by stereo-lithography (three-dimensional surface reconstruction). A modified version of the Holmquist-Johnson-Cook (MHJC) material model was calibrated using Kuru granite test results available from the literature. Numerical simulations of the single drop tests were carried out using the MHJC model available in the LS-DYNA explicit finite-element solver. The influence of the impact energy and additional confining pressure on the BRI curves and the volume of the removed rock is discussed. In addition, the influence of the rock surface shape before impact was evaluated using two different mesh geometries: a flat surface and a hyperbolic surface. The experimental and numerical results are compared and discussed in terms of drilling efficiency through the mechanical specific energy. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  8. Preliminary tests of silicon carbide based concretes for hybrid rocket nozzles in a solar furnace

    Science.gov (United States)

    D'Elia, Raffaele; Bernhart, Gérard; Cutard, Thierry; Peraudeau, Gilles; Balat-Pichelin, Marianne

    2014-06-01

    This research is part of the PERSEUS project, a space program concerning hybrid propulsion and supported by CNES. The main goal of this study is to characterise silicon carbide based micro-concrete with a maximum aggregates size of 800 μm, in a hybrid propulsion environment. The nozzle throat has to resist to a highly oxidising polyethylene (PE)/N2O hybrid environment, under temperatures ranging up to 2980 K. The study is divided into two main parts: the first one deals with the thermo-mechanical characterisation of the material up to 1500 K and the second one with an investigation on the oxidation behaviour in a standard atmosphere, under a solar flux up to 13.5 MW/m2. Young's modulus was determined by resonant frequency method: results show an increase with the stabilisation temperature. Four point bending tests have shown a rupture tensile strength increasing with stabilisation temperature, up to 1473 K. Sintering and densification processes are primary causes of this phenomenon. Visco-plastic behaviour appears at 1373 K, due to the formation of liquid phases in cement ternary system. High-temperature oxidation in ambient air was carried out at PROMES-CNRS laboratory, on a 2 kW solar furnace, with a concentration factor of 15,000. A maximum 13.5 MW/m2 incident solar flux and a 7-90 s exposure times have been chosen. Optical microscopy, SEM, EDS analyses were used to determine the microstructure evolution and the mass loss kinetics. During these tests, silicon carbide undergoes active oxidation with production of SiO and CO smokes and ablation. A linear relation between mass loss and time is found. Oxidation tests performed at 13.5 MW/m2 solar flux have shown a mass loss of 10 mg/cm2 after 15 s. After 90 s, the mass loss reaches 60 mg/cm2. Surface temperature measurement is a main point in this study, because of necessity of a thermo-mechanical-ablative model for the material. Smokes appear at around 5.9 MW/m2, leading to the impossibility of useful temperature

  9. Preliminary Study on Mg content of hard part(Test) of a benthic foraminifer from the inner shelf, off West Coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Khare, N.; Nigam, R.; Iyer, S.D.

    A preliminary study has been made for trace element (Mg) in the test of benthic species Bulimina exilis from a shallow sediment core (at 22 m water depth) off west coast of India using Electron Probe Microanalyser (EPMA) The Mg content is selected...

  10. Preliminary testing of the role of exercise and predator recognition for bonytail and razorback sucker

    Science.gov (United States)

    Mueller, Gordon A.; Carpenter, Jeanette; Krapfel, Robert; Figiel, Chester

    2007-01-01

    Hatchery-reared juvenile, suckers appeared curious and showed no sign of predator avoidance when initially placed with large (>45-cm TL) flathead catfish. Predator-naïve juveniles (20- to 25-cm TL) exhibited no discernable preference when provided areas with and without (52 percent and 48 percent, n = 16 observations; 46 percent and 54 percent, n = 20 observations) large flathead catfish. However, once predation occurred, use of predator-free areas nearly doubled in two trials (36 percent and 64 percent, n = 50 observations; 33 percent and 67 percent, n = 12 observations). A more stringent test examining available area indicated predator-savvy razorback suckers used predator-free areas (88 percent, n = 21) illustrating predator avoidance was a learned behavior.

  11. Some Preliminary Notes on an Empirical Test of Freud’s Theory on Depression

    Directory of Open Access Journals (Sweden)

    Mattias eDesmet

    2013-05-01

    Full Text Available A review of the literature indicates that empirical researchers have difficulty translating Freud’s theory on depression into appropriate research questions and hypotheses. In their attempt to do so, the level of complexity in Freud’s work is often lost. As a result, what is empirically tested is no more than a caricature of the original theory. To help researchers avoid such problems, this study presents a conceptual analysis of Freud’s theory of depression as it is presented in Mourning and Melancholia (Freud, 1917. In analyzing Freud’s theory on the etiology of depression, it is essential to differentiate between (1 an identification with the satisfying and frustrating aspects of the love object, (2 the inter- and an intrapersonal loss of the love object, and (3 conscious and unconscious dynamics. A schematic representation of the mechanism of depression is put forward and a research design by which this schema can be empirically investigated is outlined.

  12. Preliminary indications for antibiotic susceptibility tests in less than six hour in positive blood cultures

    Directory of Open Access Journals (Sweden)

    Vesselina Kroumova

    2010-03-01

    Full Text Available A rapid determination of the antibiotic susceptibility patterns of pathogens responsible for sepsis represents a significant milestone for a timely correct antibiotic therapy.The system HB&L® (ALIFAX allows reduced time in the detection of bacterial growth and consequently is able to detect the growth or absence of certain microorganisms in the presence of a given antibiotic. In this study three system for rapid antibiotic susceptibility tests among bacteria isolated from blood were compared: HB&L® (ALIFAX,VITEK®2 (bioMérieux and essays Etest® (bioMérieux. Present findings indicate that HB&L® (ALIFAX is rapid reliable instrument that may support the clinician for a rapid and appropriate treatment, particularly in the critical patient.

  13. [Preliminary application of video head impulse test in the diagnosis of vertigo].

    Science.gov (United States)

    Zhang, Yanmei; Chen, Siqi; Zhong, Zhen; Chen, Li; Wu, Yuanding; Zhao, Guiping; Liu, Yuhe

    2015-06-01

    To investigate clinical application of head impulse test with video recording eye movements in the diagnosis of vertigo. The video head impulse test(vHIT) was used to measure the eye saccades and velocity gain in 95 patients with vertigo which were divided into two groups, peripheral vertigo (47 cases) and central vertigo(48 cases); the characteristics of eye saccades and velocity gain of six semicircular canals in different patients with vertigo were analyzed, and were compared between the two groups. The vHIT result in patients with peripheral vertigo: in 22 patients (23 affected ears) with Meniere's disease, 21 ears were abnormal (91. 3%); the vHIT results in 4 patients with vestibular schwannoma, 2 patients with vestibular neuritis, 5 patients with delayed endolymphatic hydrops, 6 patients with sudden hearing loss accompanied vertigo, and 8 patients with vestibular dysfunction, were abnormal with correct saccades and/or lower velocity gain of vHIT. The abnormal vHIT results were also found in 35 of 48 patients (72. 9%) with central vertigo, which including posterior cerebral circulation ischemia(7 patients), cerebral infarction/stroke(6 patients), and dizziness with vertigo(17 patients) and others(18 patients). Abnormal rate of vHIT in patients with peripheral vertigo was 95. 7% (45/47), which was significantly higher than that (72. 9%) in patients with central vertigo. It is easy to perform the vHIT which without adverse reactions. We can record high-frequency characteristics of vestibular-ocular reflex among six semicircular canals through vHIT. The vHIT results which show the function of vestibular ocular reflex in different diseases with vertigo, can help discriminate peripheral vertigo from central vertigo, and it is a practical assessment method for vertigo.

  14. [Development of external quality control protocol for CyberKnife beams dosimetry: preliminary tests multicentre].

    Science.gov (United States)

    Guinement, L; Marchesi, V; Veres, A; Lacornerie, T; Buchheit, I; Peiffert, D

    2013-01-01

    To develop an external quality control procedure for CyberKnife(®) beams. This work conducted in Nancy, has included a test protocol initially drawn by the medical physicist of Nancy and Lille in collaboration with Equal-Estro Laboratory. A head and neck anthropomorphic phantom and a water-equivalent homogeneous cubic plastic test-object, so-called "MiniCube", have been used. Powder and solid thermoluminescent dosimeters as well as radiochromic films have been used to perform absolute and relative dose studies, respectively. The comparison between doses calculated by Multiplan treatment planning system and measured doses have been studied in absolute dose. The dose distributions measured with films and treatment planning system calculations have been compared via the gamma function, configured with different tolerance criteria. This work allowed, via solid thermoluminescent dosimeter measurements, verifying the beam reliability with a reproducibility of 1.7 %. The absolute dose measured in the phantom irradiated by the seven participating centres has shown an error inferior to the standard tolerance limits (± 5 %), for most of participating centres. The relative dose measurements performed at Nancy and by the Equal-Estro laboratory allowed defining the most adequate parameters for gamma index (5 %/2mm--with at least 95 % of pixels satisfying acceptability criteria: γsoftware. This work allowed defining a dosimetric external quality control for CyberKnife(®) systems, based on a reproducible irradiation plan through measurements performed with thermoluminescent dosimeters and radiochromic films. This protocol should be validated by a new series of measurement and taking into account the lessons of this work. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  15. Protein folding: Defining a standard set of experimental conditions and a preliminary kinetic data set of two-state proteins

    DEFF Research Database (Denmark)

    Maxwell, Karen L.; Wildes, D.; Zarrine-Afsar, A.;

    2005-01-01

    constructs. The lack of a single approach to data analysis and error estimation, or even of a common set of units and reporting standards, further hinders comparative studies of folding. In an effort to overcome these problems, we define here a consensus set of experimental conditions (25°C at pH 7.0, 50 m...... rates, thermodynamics, and structure across diverse sets of proteins. These difficulties include the wide, potentially confounding range of experimental conditions and methods employed to date and the difficulty of obtaining correct and complete sequence and structural details for the characterized......M buffer), data analysis methods, and data reporting standards that we hope will provide a benchmark for experimental studies. We take the first step in this initiative by describing the folding kinetics of 30 apparently two-state proteins or protein domains under the consensus conditions. The goal of our...

  16. The impact of neurodynamic testing on the perception of experimentally induced muscle pain.

    Science.gov (United States)

    Coppieters, Michel W; Kurz, Kimberly; Mortensen, Thor Einar; Richards, Nicola L; Skaret, Ingrid A; McLaughlin, Laurie M; Hodges, Paul W

    2005-02-01

    Neurodynamic tests such as the straight leg raising (SLR) and slump test are frequently used for assessment of mechanosensitivity of neural tissues. However, there is ongoing debate in the literature regarding the contributions of neural and non-neural tissues to the elicited symptoms because many structures are affected by these tests. Sensitizing manoeuvres are limb or spinal movements added to neurodynamic tests, which aim to identify the origin of the symptoms by preferentially loading or unloading neural structures. A prerequisite for the use of sensitizing manoeuvres to identify neural involvement is that the addition of sensitizing manoeuvres has no impact on pain perception when the origin of the pain is non-neural. In this study, experimental muscle pain was induced by injection of hypertonic saline in tibialis anterior or soleus in 25 asymptomatic, naive volunteers. A first experiment investigated the impact of hip adduction, abduction, medial and lateral rotation in the SLR position. In a second experiment, the different stages of the slump test were examined. The intensity and area of experimentally induced muscle pain did not increase when sensitizing manoeuvres were added to the SLR or throughout the successive stages of the slump test. The findings of this study lend support to the validity of the use of sensitizing manoeuvres during neurodynamic testing.

  17. Treatment of mechanically sorted organic waste by bioreactor landfill: Experimental results and preliminary comparative impact assessment with biostabilization and conventional landfill.

    Science.gov (United States)

    Di Maria, Francesco; Micale, Caterina; Sisani, Luciano; Rotondi, Luca

    2016-09-01

    Treatment and disposal of the mechanically sorted organic fraction (MSOF) of municipal solid waste using a full-scale hybrid bioreactor landfill was experimentally analyzed. A preliminary life cycle assessment was used to compare the hybrid bioreactor landfill with the conventional scheme based on aerobic biostabilization plus landfill. The main findings showed that hybrid bioreactor landfill was able to achieve a dynamic respiration index (DRI)55% v/v started within 140days from MSOF disposal, allowing prompt energy recovery and higher collection efficiency. With the exception of fresh water eutrophication with the bioreactor scenario there was a reduction of the impact categories by about 30% compared to the conventional scheme. Such environmental improvement was mainly a consequence of the reduction of direct and indirect emissions from conventional aerobic biostabilization and of the lower amount of gaseous loses from the bioreactor landfill. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. COMMENT: Comment on 'Experimental realization of a first test of de Broglie Bohm theory'

    Science.gov (United States)

    Akhavan, O.; Golshani, M.

    2004-09-01

    In a recent paper, Brida et al (2002 J. Phys. B: At. Mol. Opt. Phys. 35 4751) reported the first experimental realization for testing of de Broglie-Bohm (dBB) theory against standard quantum mechanics (SQM), based on a suggested scheme presented in Golshani and Akhavan (2001 J. Phys. A: Math. Gen. 34 5259). However, some details of their experiment are not compatible with our suggestion. Therefore, their conclusion, in which the experimental data are in complete agreement with SQM but show some deviations from dBB predictions, cannot be considered as a final verdict.

  19. Experimental research on mercury emission from one-dimensional combustion test facility

    Institute of Scientific and Technical Information of China (English)

    WANG Quan-hai(王泉海); QIU Jian-rong(邱建荣); LIU Jing(刘晶); ZHANG Jun-ying(张军营)

    2004-01-01

    The research of mercury release from coal combustion and mercury speciation in flue gas was conducted in a one-dimensional combustion test facility. The experimental results indicated that combustion temperature was the primary factor in affecting mercury vaporization and release. Experimental measurements showed high mercury levels in the particulate phase. Hg(S) is enriched in fly ash and dispersed in bottom ash. Hg(B) content decreases and the Hg(F) content increases with higher furnace temperature. At 1 100℃, the levels of Hg2+(g) are 17%~48% for limited chemical kinetics .The mercury equilibrium in the flue-gas is frozen below some temperature.

  20. Experimental test of state-independent quantum contextuality of an indivisible quantum system

    Science.gov (United States)

    Huang, Yun-Feng; Li, Meng; Cao, Dong-Yang; Zhang, Chao; Zhang, Yong-Sheng; Liu, Bi-Heng; Li, Chuan-Feng; Guo, Guang-Can

    2013-05-01

    We report a state-independent experimental test of quantum contextuality of a single-photon qutrit. The experimental results demonstrate violations of an inequality originally formulated by Yu and Oh [Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.108.030402 108, 030402 (2012)] and further optimized by Cabello [Phys. Rev. APLRAAN1050-294710.1103/PhysRevA.85.032108 85, 032108 (2012)]; this inequality is satisfied by all noncontextual hidden variable models and is violated by all qutrit states. Our experiment shows quantum contextuality of this nature in a most fundamental way: A way that is independent of state and unrelated to entanglement.

  1. Preliminary Correlation Map of Geomorphic Surfaces in North-Central Frenchman Flat, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada

    2005-08-01

    This correlation map (scale = 1:12,000) presents the results of a mapping initiative that was part of the comprehensive site characterization required to operate the Area 5 Radioactive Waste Management Site, a low-level radioactive waste disposal facility located in northern Frenchman Flat at the Nevada Test Site. Eight primary map units are recognized for Quaternary surfaces: remnants of six alluvial fan or terrace surfaces, one unit that includes colluvial aprons associated with hill slopes, and one unit for anthropogenically disturbed surfaces. This surficial geology map provides fundamental data on natural processes for reconstruction of the Quaternary history of northern Frenchman Flat, which in turn will aid in the understanding of the natural processes that act to develop the landscape, and the time-frames involved in landscape development. The mapping was conducted using color and color-infrared aerial photographs and field verification of map unit composition and boundaries. Criteria for defining the map unit composition of geomorphic surface units are based on relative geomorphic position, landform morphology, and degree of preservation of surface morphology. The bedrock units identified on this map were derived from previous published mapping efforts and are included for completeness.

  2. Preliminary operational results of the low-temperature solar industrial process heat field tests

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.F.; Davenport, R.L.

    1980-06-01

    Six solar industrial process heat field tests have been in operation for a year or more - three are hot water systems and three are hot air systems. All are low-temperature projects (process heat at temperatures below 212/sup 0/F). Performance results gathered by each contractor's data acquisition system are presented and project costs and problems encountered are summarized. Flat-plate, evacuated-tube, and line-focus collectors are all represented in the program, with collector array areas ranging from 2500 to 21,000 ft/sup 2/. Collector array efficiencies ranged from 12% to 36% with net system efficiencies from 8% to 33%. Low efficiencies are attributable in some cases to high thermal losses and, for the two projects using air collectors, are due in part to high parasitic power consumption. Problems have included industrial effluents on collectors, glazing and absorber surface failures, excessive thermal losses, freezing and overheating, control problems, and data acquisition system failure. With design and data acquisition costs excluded costs of the projects ranged from $25/ft/sup 2/ to $87/ft/sup 2/ and $499/(MBtu/yr) to $1537/(MBtu/yr).

  3. Preliminary photovoltaic arc-fault prognostic tests using sacrificial fiber optic cabling.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Blemel, Kenneth D.; Peter, Francis

    2013-02-01

    Through the New Mexico Small Business Assistance Program, Sandia National Laboratories worked with Sentient Business Systems, Inc. to develop and test a novel photovoltaic (PV) arc-fault detection system. The system operates by pairing translucent polymeric fiber optic sensors with electrical circuitry so that any external abrasion to the system or internal heating causes the fiber optic connection to fail or detectably degrade. A periodic pulse of light is sent through the optical path using a transmitter-receiver pair. If the receiver does not detect the pulse, an alarm is sounded and the PV system can be de-energized. This technology has the unique ability to prognostically determine impending failures to the electrical system in two ways: (a) the optical connection is severed prior to physical abrasion or cutting of PV DC electrical conductors, and (b) the polymeric fiber optic cable melts via Joule heating before an arc-fault is established through corrosion. Three arc-faults were created in different configurations found in PV systems with the integrated fiber optic system to determine the feasibility of the technology. In each case, the fiber optic cable was broken and the system annunciated the fault.

  4. The physical education predisposition scale: Preliminary tests of reliability and validity in Australian students.

    Science.gov (United States)

    Hilland, Toni A; Brown, Trent D; Fairclough, Stuart J

    2017-03-30

    The main aim of this study was to psychometrically test the Physical Education Predisposition Scale (PEPS) with a cohort of Australian students, to assess secondary school students' perceived PE ability and PE worth. Secondary aims were to explore how the two variables were related and to investigate age and gender differences. Altogether, 266 Year 7, 8, 9 and 10 students (aged 12-16 years), from four schools within the South Eastern region of Melbourne, completed the PEPS at both time points. Principal components analysis revealed the presence of a simple two-factor structure explaining 66.9% of the variance. Factor 1 (labelled perceived PE worth) reflected enjoyment and attitude (α = .91), and factor 2 (labelled perceived PE ability) represented perceptions of competence and self-efficacy (α = .92). Significant positive correlations were observed between the two factors (r = .50-.82, P < .001). Boys scored significantly higher than girls on perceived PE ability (P = .01), and year 7 students scored significantly higher compared to Year 9 students (P = .002). Our results support the potential of the PEPS as a concise measurement tool for use in the PE setting, for both teachers and researchers.

  5. Medical chilling device designed for hypothermic hydration graft storage system: Design, thermohydrodynamic modeling, and preliminary testing

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Hwan [Hongik University, Seoul (Korea, Republic of)

    2015-02-15

    Hypothermic hydration graft storage is essential to reduce the metabolic demand of cells in vitro. The alleviated metabolic demands reduce the emergence rate of anaerobic metabolism generating adenosine triphosphate (ATP) energy that creates free radicals. The cessive free radicals can damage cells and tissues due to their highly oxidative power with molecules. Current cooling systems such as a conventional air cooling system and an ice pack system are inappropriate for chilling cell tissues in vitro because of inconvenience in use and inconsistent temperature sustainability caused by large size and progressive melting, respectively. Here, we develop a medical chilling device (MCD) for hypothermic hydration graft storage based on thermo-hydrodynamic modeling and thermal electric cooling technology. Our analysis of obtained hydrodynamic thermal behavior of the MCD revealed that the hypothermic condition of 4 .deg. C was continuously maintained, which increased the survival rates of cells in vitro test by reduced free radicals. The validated performance of the MCD promises future development of an optimal hypothermic hydration graft storage system designed for clinical use.

  6. The Dichotic Word Listening Test: preliminary observations in American and Canadian samples.

    Science.gov (United States)

    Roberts, M A; Persinger, M A; Grote, C; Evertowski, L M; Springer, J A; Tuten, T; Moulden, D; Franzen, K M; Roberts, R J; Baglio, C S

    1994-11-01

    The present article describes observations of 670 American and Canadian child and adult control subjects on the recently developed Dichotic Word Listening Test (DWLT). The task was also administered to a sample of American children with traumatic brain injuries (n=21) of varying severity and a sample of American adults with mild traumatic injuries (n=36). The conceptual focus in this line of research was on using normative observations to identify clinically defective channels of auditory processing among patients. The principal findings were as follow: 1) the DWLT was sensitive to the effects of cerebral dysfunction following traumatic brain injury; 2) differences among normal samples with different demographic backgrounds were frequently observed, arguing for the development of local norms; 3) a shorter form of the DWLT task (DWLT30) can be used for screening purposes with relatively little reduction in sensitivity to cerebral dysfunction; 4) there appeared to be considerable improvement of DWLT performance between the ages of five and seven, due largely to higher scores from the left auditory channel; and 5) there were indications that use of French (rather than English) as one's native language before age six can negatively influence performance in adulthood on an English version of the DWLT. In general, the present findings suggest that the DWLT is likely to have relatively broad applicability for neuropsychological assessment across the life-span.

  7. EBR-2 (Experimental Breeder Reactor-2), IFR (Integral Fast Reactor) prototype testing programs

    Energy Technology Data Exchange (ETDEWEB)

    Lehto, W.K.; Sackett, J.I.; Lindsay, R.W. (Argonne National Lab., Idaho Falls, ID (USA). EBR-II Div. Argonne National Lab., IL (USA)); Planchon, H.P.; Lambert, J.D.B. (Argonne National Lab., IL (USA))

    1990-01-01

    The Experimental Breeder Reactor-2 (EBR-2) is a sodium cooled power reactor supplying about 20 MWe to the Idaho National Engineering Laboratory (INEL) grid and, in addition, is the key component in the development of the Integral Fast Reactor (IFR). EBR-2's testing capability is extensive and has seen four major phases: (1) demonstration of LMFBR power plant feasibility, (2) irradiation testing for fuel and material development. (3) testing the off-normal performance of fuel and plant systems and (4) operation as the IFR prototype, developing and demonstrating the IFR technology associated with fuel and plant design. Specific programs being carried out in support of the IFR include advanced fuels and materials development and component testing. This paper discusses EBR-2 as the IFR prototype and the associated testing programs. 29 refs.

  8. Preliminary study towards a novel experimental model to study localized cutaneous leishmaniasis caused bY Leishmania (Leishmania mexicana

    Directory of Open Access Journals (Sweden)

    Erika Ivett Sosa-Bibiano

    2012-06-01

    Full Text Available There is not an experimental model of localized cutaneous leishmaniasis (LCL caused by Leishmania (Leishmania mexicana. The aim of the present study was to characterize the clinical and histological features of Peromyscus yucatanicus experimentally infected with L. (L. mexicana. A total of 54 P. yucatanicus (groups of 18 were inoculated with 1x10(6 promastigotes of L. (L. mexicana in the base of the tail. They were euthanized at three and six months post experimental infection. The control group was inoculated with RPMI-1640. The predominant clinical sign observed was a single ulcerated lesion in 27.77% (5/18 and in 11.11% (2/18 P. yucatanicus at three and six months respectively. The histological pattern described as chronic granulomatous inflammation with or without necrosis was found in 7/7 (100% biopsies of euthanized P. yucatanicus at three (n = 5 and six (n = 2 months, respectively. These results resembled clinical and histological features caused by L. (L. mexicana in humans, and support the possibility to employ P. yucatanicus as a novel experimental model to study LCL caused by this parasite.

  9. Preliminary fMRI findings in experimentally sleep-restricted adolescents engaged in a working memory task

    Directory of Open Access Journals (Sweden)

    Tlustos Sarah J

    2009-02-01

    Full Text Available Abstract Here we report preliminary findings from a small-sample functional magnetic resonance imaging (fMRI study of healthy adolescents who completed a working memory task in the context of a chronic sleep restriction experiment. Findings were consistent with those previously obtained on acutely sleep-deprived adults. Our data suggest that, when asked to maintain attention and burdened by chronic sleep restriction, the adolescent brain responds via compensatory mechanisms that accentuate the typical activation patterns of attention-relevant brain regions. Specifically, it appeared that regions that are normally active during an attention-demanding working memory task in the well-rested brain became even more active to maintain performance after chronic sleep restriction. In contrast, regions in which activity is normally suppressed during such a task in the well-rested brain showed even greater suppression to maintain performance after chronic sleep restriction. Although limited by the small sample, study results provide important evidence of feasibility, as well as guidance for future research into the functional neurological effects of chronic sleep restriction in general, the effects of sleep restriction in children and adolescents, and the neuroscience of attention and its disorders in children.

  10. Preliminary testing of a compact bone-attached robot for otologic surgery

    Science.gov (United States)

    Dillon, Neal P.; Balachandran, Ramya; Motte dit Falisse, Antoine; Wanna, George B.; Labadie, Robert F.; Withrow, Thomas J.; Fitzpatrick, J. Michael; Webster, Robert J.

    2014-03-01

    Otologic surgery often involves a mastoidectomy procedure, in which part of the temporal bone is milled away in order to visualize critical structures embedded in the bone and safely access the middle and inner ear. We propose to automate this portion of the surgery using a compact, bone-attached milling robot. A high level of accuracy is required t o avoid damage to vital anatomy along the surgical path, most notably the facial nerve, making this procedure well-suited for robotic intervention. In this study, several of the design considerations are discussed and a robot design and prototype are presented. The prototype is a 4 degrees-of-freedom robot similar to a four-axis milling machine that mounts to the patient's skull. A positioning frame, containing fiducial markers and attachment points for the robot, is rigidly attached to the skull of the patient, and a CT scan is acquired. The target bone volume is manually segmented in the CT by the surgeon and automatically converted to a milling path and robot trajectory. The robot is then attached to the positioning frame and is used to drill the desired volume. The accuracy of the entire system (image processing, planning, robot) was evaluated at several critical locations within or near the target bone volume with a mean free space accuracy result of 0.50 mm or less at all points. A milling test in a phantom material was then performed to evaluate the surgical workflow. The resulting milled volume did not violate any critical structures.

  11. Brazilian Portuguese adaptation of Dyslexia Early Screening Test - Second edition: preliminary findings.

    Science.gov (United States)

    Matta, Tatiana Ribeiro Gomes da; Befi-Lopes, Debora Maria

    2015-01-01

    The assessment of language skills in early childhood can provide important information about the future of literacy and academic performances. Children with reading difficulties should be identified early in their education, before they suffer from shortcomings and experience failures and feel discouraged at school. Considering the importance of early identification of language disorders and the shortage of standardized instruments for the Brazilian scenario, the overall objective of this study was to translate and adapt the Dyslexia Early Screening Test - Second Edition (DEST-2) to, subsequently, verify its applicability and efficacy in preschoolers who had Brazilian Portuguese as their native language. The study was composed of 20 children of both genders, regularly enrolled in a public school in the metropolitan region of São Paulo, none had any complaints related to learning and no indicators of sensory, neurological, cognitive, or behavioral disorders. It was observed that there was no need for significant changes to the original structure of the DEST-2 or in their administration instructions format. The performance of the children in the translated and in the national exams that were used as a benchmark was compatible, suggesting that the adjustments made met the equivalences needed to utilize this instrument with Brazilian children. A randomized study that will complement the preliminarily data obtained is in progress. Taking into consideration the linguistic and cultural diversity of Brazil, it is imperative that the translated version of the DEST-2 can be applied on a large scale and in several states of the country, in order to allow the use of this instrument as a language assessment tool in Brazil.

  12. Balance impairment in people with multiple sclerosis: preliminary evidence for the Balance Evaluation Systems Test.

    Science.gov (United States)

    Jacobs, Jesse V; Kasser, Susan L

    2012-07-01

    This study examined the validity of the Balance Evaluation Systems Test (BESTest) to identify balance impairments in people with multiple sclerosis (MS) by evaluating differences in BESTest performance between people with and without MS. We also assessed the BESTest's validity by correlation with objective measures of postural performance as well as with disease severity and fall status. Thirteen subjects with MS (Expanded Disability Status Scale; EDSS: 0-4.5) and 13 matched subjects without MS were evaluated on the BESTest, asked about fall history, and assessed by force plates and motion capture as they performed laboratory tasks of step initiation, forward leaning to the limits of stability, and postural responses to rotations of the support surface. Compared to subjects without MS, subjects with MS exhibited lower total BESTest scores (mean (95%) score for subjects with MS=91 (83-99); subjects without MS=105 (104-107)) as well as section scores pertaining to mechanical constraints, limits of stability, anticipatory postural adjustments, and gait. BESTest scores significantly correlated with objective laboratory measures of step velocity during step initiation (Pearson r(2)=0.48, P<0.01) as well as center-of-pressure displacements during both the leaning (Pearson r(2)=0.55, P<0.005) and postural-response tasks (Pearson r(2)=0.76, P<0.0001). BESTest total scores were 92% accurate to identify fallers and non-fallers, and BESTest scores significantly correlated with EDSS scores (Spearman's rho=0.85, P<0.0005). Thus, the BESTest provides a valid clinical assessment of balance impairments in people with MS.

  13. Experimental testing method for solar light simulator with an attached evacuated solar collector

    Directory of Open Access Journals (Sweden)

    Mahmoud Shatat, Saffa Riffat, Francis Agyenim

    2013-01-01

    Full Text Available This paper describes a novel solar simulator of high solar irradiation. It consists of an array of 30 halogen lamps of 400W each, covering a gross area of 2.32 m2. A standardized empirical method for solar simulator testing facility based on an experimental performance is presented. A uniform geometrical configuration design for a solar simulator was evaluated by its illuminance distribution to optimize the maximum source-to-target transfer efficiency of irradiative power. Experimental tests were carried out for various distances from the simulator surface. It was determined that the optimal distance between the light surface simulator and the solar collector is about 23 cm at different solar irradiance. The unevenness of solar radiation values were investigated at different points under the simulator facility and the maximum unevenness error percentage was found to be about 9.1%, which is well within the allowable limits of 15% set by British Standards for testing a solar simulator . The performance of an evacuated solar collector with an aperture area of 1.73 m2 to simulate solar insolation during March in the Middle East region was investigated and it was proved that the efficiency of the solar collector was closely correlated with the efficiency data provided by the manufacturer. The design of such a solar light simulator associated with the development of a standardized test procedure can be utilized as a reliable and efficient experimental platform to investigate various solar collectors and materials.

  14. SIRHEX—A new experimental facility for high heat flux testing of plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Kunze, André, E-mail: andre.kunze@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (Germany); Ghidersa, Bradut-Eugen [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (Germany); Bonelli, Flavia [Politecnico di Torino, Dipartimento Energia (Italy)

    2015-10-15

    Highlights: • Commercial infrared heaters have been qualified for future First Wall experiments. • In first tests surface heat flux densities up to 470 kW/m were achieved. • The homogeneity of the heat distribution stayed within ±5% of the nominal value. • With the heaters a typical ITER pulse can be reproduced. • An adequate testing strategy will be required to improve heater lifetime. - Abstract: SIRHEX (“Surface Infrared Radiation Heating Experiment”) is a small-scale experimental facility at KIT, which has been built for testing and qualifying high heat flux radiation heaters for blanket specific conditions using an instrumented water cooled target. This paper describes the SIRHEX facility and the experimental set-up for the heater tests. The results of a series of tests focused on reproducing homogeneous surface heat flux densities up to 500 kW/m{sup 2} will be presented and the impact of the heater performance on the design of the First Wall test rig will be discussed.

  15. Green-Kubo relation for viscosity tested using experimental data for a 2D dusty plasma

    CERN Document Server

    Feng, Yan; Liu, Bin; Cohen, E G D

    2011-01-01

    The theoretical Green-Kubo relation for viscosity is tested using experimentally obtained data. In a dusty plasma experiment, micron-size dust particles are introduced into a partially-ionized argon plasma, where they become negatively charged. They are electrically levitated to form a single-layer Wigner crystal, which is subsequently melted using laser heating. In the liquid phase, these dust particles experience interparticle electric repulsion, laser heating, and friction from the ambient neutral argon gas, and they can be considered to be in a nonequilibrium steady state. Direct measurements of the positions and velocities of individual dust particles are then used to obtain a time series for an off-diagonal element of the stress tensor and its time autocorrelation function. This calculation also requires the interparticle potential, which was not measured experimentally, but was obtained using a Debye-H\\"{u}ckel-type model with experimentally determined parameters. Integrating the autocorrelation functi...

  16. Facility for Advanced Accelerator Experimental Tests at SLAC (FACET) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.; Bane, K.; /SLAC

    2009-10-30

    This Conceptual Design Report (CDR) describes the design of FACET. It will be updated to stay current with the developing design of the facility. This CDR begins as the baseline conceptual design and will evolve into an 'as-built' manual for the completed facility. The Executive Summary, Chapter 1, gives an introduction to the FACET project and describes the salient features of its design. Chapter 2 gives an overview of FACET. It describes the general parameters of the machine and the basic approaches to implementation. The FACET project does not include the implementation of specific scientific experiments either for plasma wake-field acceleration for other applications. Nonetheless, enough work has been done to define potential experiments to assure that the facility can meet the requirements of the experimental community. Chapter 3, Scientific Case, describes the planned plasma wakefield and other experiments. Chapter 4, Technical Description of FACET, describes the parameters and design of all technical systems of FACET. FACET uses the first two thirds of the existing SLAC linac to accelerate the beam to about 20GeV, and compress it with the aid of two chicanes, located in Sector 10 and Sector 20. The Sector 20 area will include a focusing system, the generic experimental area and the beam dump. Chapter 5, Management of Scientific Program, describes the management of the scientific program at FACET. Chapter 6, Environment, Safety and Health and Quality Assurance, describes the existing programs at SLAC and their application to the FACET project. It includes a preliminary analysis of safety hazards and the planned mitigation. Chapter 7, Work Breakdown Structure, describes the structure used for developing the cost estimates, which will also be used to manage the project. The chapter defines the scope of work of each element down to level 3.

  17. Speech and pause characteristics in multiple sclerosis: A preliminary study of speakers with high and low neuropsychological test performance

    Science.gov (United States)

    FEENAUGHTY, LYNDA; TJADEN, KRIS; BENEDICT, RALPH H.B.; WEINSTOCK-GUTTMAN, BIANCA

    2017-01-01

    This preliminary study investigated how cognitive-linguistic status in multiple sclerosis (MS) is reflected in two speech tasks (i.e. oral reading, narrative) that differ in cognitive-linguistic demand. Twenty individuals with MS were selected to comprise High and Low performance groups based on clinical tests of executive function and information processing speed and efficiency. Ten healthy controls were included for comparison. Speech samples were audio-recorded and measures of global speech timing were obtained. Results indicated predicted differences in global speech timing (i.e. speech rate and pause characteristics) for speech tasks differing in cognitive-linguistic demand, but the magnitude of these task-related differences was similar for all speaker groups. Findings suggest that assumptions concerning the cognitive-linguistic demands of reading aloud as compared to spontaneous speech may need to be re-considered for individuals with cognitive impairment. Qualitative trends suggest that additional studies investigating the association between cognitive-linguistic and speech motor variables in MS are warranted. PMID:23294227

  18. A new airborne Polar Nephelometer for the measurement of optical and microphysical cloud properties. Part II: Preliminary tests

    Directory of Open Access Journals (Sweden)

    O. Crépel

    Full Text Available A new optical sensor, the airborne Polar Nephelometer, has been tested in an open wind tunnel. The wind tunnel was operated in cloudy conditions including either cloud water droplets or ice crystals, or a mixture of these particles. The sensor is designed to measure the optical and microphysical parameters of cloud particles sized from a few micrometers to about 500 µm diameter. Basically, the probe measures the scattering phase function of an ensemble of cloud particles which intersect a collimated laser beam near the focal point of a paraboloidal mirror. From the measured scattering phase function the retrieval of the droplet-size spectra and subsequent derived quantities such as liquid water content and size parameters can be calculated using an inversion method. The particle phase discrimination (water droplets/ice particles can be derived from the shape of the scattering phase function and the sensitivity of the probe allows the detection of small ice crystals (typically of 5 µm diameter. The paper describes the preliminary results obtained by the prototype version of the Polar Nephelometer in various cloudy conditions. These results are compared with direct microphysical measurements obtained by usual PMS probes also mounted in the wind tunnel. Complementary results obtained in a cold chamber are presented in order to illustrate the reliability of the Polar Nephelometer in the presence of small ice crystals.

  19. Performance characteristics of selected immunoassays for preliminary test of 3,4-methylenedioxymethamphetamine, methamphetamine, and related drugs in urine specimens.

    Science.gov (United States)

    Hsu, Jui; Liu, Chiareiy; Liu, C P; Tsay, Wen-Ing; Li, Jih-Heng; Lin, Dong-Liang; Liu, Ray H

    2003-10-01

    Eight commercially available immunoassays for amphetamines (DRI Amphetamines, CEDIA DAU Amphetamines-Semiquantitative, EMIT d.a.u. Monoclonal Amphetamine/Methamphetamine, Synchron CX Systems AMPH, TDx/TDxFLx Amphetamine/Methamphetamine II, CEDIA Amphetamines/Ecstasy, COBAS INTEGRA Amphetamines, and Abuscreen((R)) OnLine HS Amphetamine/MDMA) are evaluated for their effectiveness in serving as the preliminary test methodology for the analysis of 3,4-methylenedioxymethamphetamine/3,4-methylenedioxyamphetamine (MDMA/MDA) and methamphetamine/amphetamine (MA/AM). Standard solutions (in urine matrix) of MDMA, MDA, MA, and AM are used to determine these immunoassays' reactivities (or cross-reactivities) toward these compounds of interest. Case specimens containing MDMA/MDA and MA/AM are also used to study the correlations of the apparent immunoassay MDMA (or MA) concentrations and the gas chromatographic-mass spectrometric concentrations of these compounds. Data resulting from this study suggest that CEDIA Amphetamines/Ecstasy can best predict the concentrations of MDMA and MA in case specimens and can also detect the presence of MDMA at low levels, whereas Abuscreen OnLine HS Amphetamine/MDMA can detect both MDMA and MA at low concentrations.

  20. Preliminary Testing of a Patient-Reported Outcome Measure for Recurrent or Metastatic Head and Neck Cancer.

    Science.gov (United States)

    Jackson, Leanne K; Deng, Jie; Ridner, Sheila H; Gilbert, Jill; Dietrich, Mary S; Murphy, Barbara A

    2016-05-01

    We describe development and preliminary testing of Vanderbilt Head and Neck Symptom Survey-Recurrent/Metastatic (VHNSS-RM) to assess residual symptoms, tumor-related symptoms, and side effects from therapy. Items were identified through patient and provider interviews. Card sort selected high-yield and high-impact items. The VHNSS-RM was administered to 50 patients with recurrent/metastatic head and neck cancer (RMHNC). The VHNSS-RM includes 12 unique symptoms (diet change, tongue movement affecting speech/swallowing, face/neck swelling, neck/jaw cramping, bad breath, drooling, wound drainage/pain/odor, nasal congestion/drainage, eyes watering, face/tongue/ear/scalp numbness, headaches, and confusion) and 7 unique psychosocial issues (burden to family/friends, lost independence, fear, embarrassment, mood swings, stress, and boredom). The VHNSS-RM contains 35 physical and 12 psychosocial issues. The VHNSS-RM is feasible and not overly burdensome. Nineteen unique items may improve palliation to patients with RMHNC. © The Author(s) 2015.

  1. A Preliminary Test of the Interpersonal-Psychological Theory of Suicide in Women Seeking Shelter From Intimate Partner Violence.

    Science.gov (United States)

    Wolford-Clevenger, Caitlin; Smith, Phillip N; Kuhlman, Shane; D'Amato, Darcey

    2016-07-25

    Women seeking shelter from intimate partner violence (IPV) are at greater risk of suicide ideation and attempts compared with women in the general population. A theoretically grounded understanding of suicide risk in shelter-seeking women is critical to improve assessment and management of suicide risk in this population. The interpersonal-psychological theory of suicide (IPTS) proposes that suicide ideation results from hopelessness about thwarted belongingness and perceived burdensomeness. However, suicide ideation does not progress to death by suicide unless one has acquired the capability for suicide (i.e., pain tolerance and fearlessness about death) via repeated exposure to painful and fearsome events. The present study provides a preliminary test of the IPTS in a sample of 134 women seeking shelter from IPV. First, we examined factors theoretically related to suicide ideation, demonstrating that only at high levels of hopelessness was perceived burdensomeness associated with suicide ideation. The study also examined factors theoretically related to the acquired capability for suicide (ACS), indicating that physical partner violence perpetration was associated with ACS. These findings suggest that perceived burdensomeness, particularly in the context of increased hopelessness, is important in the assessment and treatment of suicide ideation. Furthermore, violence perpetration may indicate greater risk of the capability to die by suicide among women seeking shelter from IPV. © The Author(s) 2016.

  2. Preliminary PINC(Program for the Inspection of Nickel Alloy Components) RRT(Round Robin Test) - Pressurizer Dissimilar Metal Weld

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kang, Sung Sik; Shin, Ho Sang; Chung, Ku Kab; Song, Myung Ho; Chung, Hae Dong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2009-06-15

    After several damages by PWSCC were found in the world, USNRC and PNNL(Pacific Northwest National Laboratory) started the research on PWSCC under the project name of PINC. The aim of the project was 1) to fabricate representative NDE mock-ups with flaws to simulate PWSCCs, 2) to identify and quantitatively assess NDE methods for accurately detecting, sizing and characterizing PWSCCs, 3) to document the range of locations and morphologies of PWSCCs and 4) to incorporate results with other results of ongoing PWSCC research programs, as appropriate. Korea nuclear industries have also been participating in the project. Thermally and mechanically cracked-four mockups were prepared and phased array and manual ultrasonic testing(UT) techniques were applied. The results and lessons learned from the preliminary RRT are summarized as follows: 1) Korea RRT teams performed the RRT successfully. 2) Crack detection probability of the participating organizations was an average 87%, 80% and 80% respectively. 3) RMS error of the crack sizing showed comparatively good results. 4) The lessons learned may be helpful to perform the PINC RRT and PSI /ISI in Korea in the future.

  3. Preliminary assessment of existing experimental data for validation ofreactor physics codes and data for NGNP design and analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Terry, W. K.; Jewell, J. K.; Briggs, J. B.; Taiwo, T. A.; Park, W.S.; Khalil, H. S.

    2005-10-25

    The Next Generation Nuclear Plant (NGNP), a demonstration reactor and hydrogen production facility proposed for construction at the INEEL, is expected to be a high-temperature gas-cooled reactor (HTGR). Computer codes used in design and safety analysis for the NGNP must be benchmarked against experimental data. The INEEL and ANL have examined information about several past and present experimental and prototypical facilities based on HTGR concepts to assess the potential of these facilities for use in this benchmarking effort. Both reactors and critical facilities applicable to pebble-bed and prismatic block-type cores have been considered. Four facilities--HTR-PROTEUS, HTR-10, ASTRA, and AVR--appear to have the greatest potential for use in benchmarking codes for pebble-bed reactors. Similarly, for the prismatic block-type reactor design, two experiments have been ranked as having the highest priority--HTTR and VHTRC.

  4. Sodium alginate as an ideal submucosal injection material for endoscopic submucosal resection: preliminary experimental and clinical study.

    Science.gov (United States)

    Akagi, Tomonori; Yasuda, Kazuhiro; Tajima, Masaaki; Suzuki, Kosuke; Inomata, Masafumi; Shiraishi, Norio; Sato, Yuhki; Kitano, Seigo

    2011-11-01

    Sodium alginate is used clinically in the treatment of peptic ulcer disease. Because of its viscosity, sodium alginate could possibly become a new submucosal injection material for use in endoscopic resection. We evaluated the feasibility of endoscopic submucosal dissection (ESD) using sodium alginate. The lesion-lifting properties of sodium alginate were examined in porcine stomachs and were compared with those of normal saline solution and sodium hyaluronate solution. After confirming the proper concentration of sodium alginate, ESD using sodium alginate was performed in 11 patients with gastric mucosal cancer or adenoma. The lesion-lifting properties of sodium alginate and clinical outcomes were assessed. The thickness of the submucosal elevation created by 3% sodium alginate in porcine stomach was equivalent to that of sodium hyaluronate. ESD using sodium alginate was completed successfully in all patients without adverse effects except in 1 patient in whom transient shrinkage of the gastric wall disappeared spontaneously after approximately 30 minutes. The mean tumor size was 15.3 mm. En bloc resection and a negative resection margin were obtained in all. Histopathologic examination revealed that all tumors were confined to the mucosal layer except for 1 that was confined to the submucosal layer without lymphovascular invasion, and there were no adverse effects such as tissue damage. No patient required additional treatment, and none showed recurrence during a median follow-up period of 28 months. Small sample size. This preliminary study suggests that sodium alginate might be a novel, safe submucosal injection material for use in endoscopic resection. Further investigation of the properties of sodium alginate is warranted. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. Buckling Test Results and Preliminary Test and Analysis Correlation from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA02

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P

    2017-01-01

    Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.

  6. Hepatocyte metaplasia in experimental chagasic pancreatitis: preliminary report Metaplasia hepatocítica em pancreatite chagásica experimental: nota prévia

    Directory of Open Access Journals (Sweden)

    Vitorino Modesto dos Santos

    2001-06-01

    Full Text Available Beginning the study of chronic pathologic changes in pancreas of hamsters experimentally infected with Trypanosoma cruzi Vic strain, hepatocyte metaplasia was observed in one animal from infected group. This is the first report of oncocytes in Chagas' disease, which could be due to aberrant regenerative response to pancreas inflammatory process.Iniciando estudo de alterações patológicas crônicas no pâncreas de hamsters experimentalmente infectados com a cepa Vic de Trypanosoma cruzi, metaplasia oncocítica foi observada em um dos animais infectados. Este é o primeiro relato de oncocitos na doença de Chagas, que poderiam decorrer de resposta regenerativa aberrante ao processo inflamatório pancreático.

  7. [Experimental testing of Pflüger's reflex hypothesis of menstruation in late 19th century].

    Science.gov (United States)

    Simmer, H H

    1980-07-01

    Pflüger's hypothesis of a nerve reflex as the cause of menstruation published in 1865 and accepted by many, nonetheless did not lead to experimental investigations for 25 years. According to this hypothesis the nerve reflex starts in the ovary by an increase of the intraovarian pressure by the growing follicles. In 1884 Adolph Kehrer proposed a program to test the nerve reflex, but only in 1890, Cohnstein artificially increased the intraovarian pressure in women by bimanual compression from the outside and the vagina. His results were not convincing. Six years later, Strassmann injected fluids into ovaries of animals and obtained changes in the uterus resembling those of oestrus. His results seemed to verify a prognosis derived from Pflüger's hypothesis. Thus, after a long interval, that hypothesis had become a paradigma. Though reasons can be given for the delay, it is little understood, why experimental testing started so late.

  8. Direction and Integration of Experimental Ground Test Capabilities and Computational Methods

    Science.gov (United States)

    Dunn, Steven C.

    2016-01-01

    This paper groups and summarizes the salient points and findings from two AIAA conference panels targeted at defining the direction, with associated key issues and recommendations, for the integration of experimental ground testing and computational methods. Each panel session utilized rapporteurs to capture comments from both the panel members and the audience. Additionally, a virtual panel of several experts were consulted between the two sessions and their comments were also captured. The information is organized into three time-based groupings, as well as by subject area. These panel sessions were designed to provide guidance to both researchers/developers and experimental/computational service providers in defining the future of ground testing, which will be inextricably integrated with the advancement of computational tools.

  9. Experimental Test of an Event-Based Corpuscular Model Modification as an Alternative to Quantum Mechanics

    Science.gov (United States)

    Brida, Giorgio; Degiovanni, Ivo Pietro; Genovese, Marco; Migdall, Alan; Piacentini, Fabrizio; Polyakov, Sergey V.; Traina, Paolo

    2013-03-01

    We present the first experimental test that distinguishes between an event-based corpuscular model (EBCM) [H. De Raedt et al.: J. Comput. Theor. Nanosci. 8 (2011) 1052] of the interaction of photons with matter and quantum mechanics. The test looks at the interference that results as a single photon passes through a Mach--Zehnder interferometer [H. De Raedt et al.: J. Phys. Soc. Jpn. 74 (2005) 16]. The experimental results, obtained with a low-noise single-photon source [G. Brida et al.: Opt. Express 19 (2011) 1484], agree with the predictions of standard quantum mechanics with a reduced χ2 of 0.98 and falsify the EBCM with a reduced χ2 of greater than 20.

  10. Experimental Test of an Event-Based Corpuscular Model Modification as an Alternative to Quantum Mechanics

    CERN Document Server

    Brida, Giorgio; Genovese, Marco; Migdall, Alan; Piacentini, Fabrizio; Polyakov, Sergey V; Traina, Paolo

    2013-01-01

    We present the first experimental test that distinguishes between an event-based corpuscular model (EBCM) [H. De Raedt et al.: J. Comput. Theor. Nanosci. 8 (2011) 1052] of the interaction of photons with matter and quantum mechanics. The test looks at the interference that results as a single photon passes through a Mach-Zehnder interferometer [H. De Raedt et al.: J. Phys. Soc. Jpn. 74 (2005) 16]. The experimental results, obtained with a low-noise single-photon source [G. Brida et al.: Opt. Expr. 19 (2011) 1484], agree with the predictions of standard quantum mechanics with a reduced $\\chi^2$ of 0.98 and falsify the EBCM with a reduced $\\chi^2$ of greater than 20.

  11. Experimental modal tests applied to rotor balancing; Pruebas modales experimentales aplicadas al balanceo de rotores

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Solis, Jose Antonio; Munoz Quezada, Rodolfo; Franco Nava, Jose Manuel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1993-01-01

    At the Instituto de Investigaciones Electricas (IIE), the experimental modal tests were initiated in order to validate the numerical models used by computer programs for the study of the rotor dynamic behavior. In order to contribute to the application of the rotor balancing methods based in the calculation of their modal forms, currently the capacity to determine these modal forms and the natural frequencies of turbogenerator rotors, is being developed, through experimental modal tests. In this paper a short description is made of the technique and the results of its application in an experimental rotor and in one of the rotors of a turbogenerator, are presented. [Espanol] En el Instituto de Investigaciones Electricas (IIE), las pruebas modales experimentales se iniciaron con la finalidad de validar los modelos numericos empleados por programas de computo para el estudio del comportamiento dinamico de rotores. Con objeto de contribuir a la aplicacion de los metodos de balanceo de rotores basados en el calculo de sus formas modales, actualmente esta desarrollandose la capacidad para determinar esas formas modales y las frecuencias naturales de rotores de turbogeneradores, a traves de las pruebas modales experimentales. En este trabajo se describe brevemente la tecnica y se presentan los resultados de su aplicacion en un rotor experimental y en uno de los tres rotores de un turbogenerador.

  12. VIP 2: Experimental tests of the Pauli Exclusion Principle for electrons

    CERN Document Server

    Pichler, A; Bertolucci, S; Berucci, C; Bragadireanu, M; Cargnelli, M; Clozza, A; Curceanu, C; De Paolis, L; Di Matteo, S; D`Uffizi, A; Egger, J P; Guaraldo, C; Iliescu, M; Ishiwatari, T; Laubenstein, M; Marton, J; Milotti, E; Pietreanu, D; Piscicchia, K; Ponta, T; Sbardella, E; Scordo, A; Shi, H; Sirghi, D; Sirghi, F; Sperandio, L; Vazquez-Doce, O; Widmann, E; Zmeskal, J

    2015-01-01

    Many experiments investigated the violation of the Pauli Exclusion Principle (PEP) since its discovery in 1925. The VIP (VIolation of the Pauli Principle) experiment tested the PEP by measuring the probability for an external electron to be captured and undergo a 2p to 1s transition during its cascading process, where the 1s state is already occupied by two electrons. This transition is forbidden by the Pauli Exclusion Principle. The VIP experiment resulted in a preliminary upper limit for the probability of the violation of the PEP of 4.7 x 10^{-29}. Currently a setup for the follow-up experiment VIP 2 is under preparation. The goal of this experiment is to improve the upper limit for the violation of the PEP by two orders of magnitude, by different improvements like enhanced energy resolution of the X-ray detectors and by implementing an active shielding. Here we report currently ongoing performance tests of the new parts of the setup.

  13. Experimental tests for foot pressure analysis during orthostatic position and gait

    Directory of Open Access Journals (Sweden)

    Ganea Daniel

    2017-01-01

    Full Text Available Human body postural deviation during normal activities such as gait or orthostatic position can cause injuries. The paper presents an experimental study regarding the distribution of contact pressures during gait and orthostatic position, aiming to evaluate the load distribution between forefoot (FF and rear-foot (RF, the projection of center of gravity and the support area variation while conducting stability metering and feet load distribution tests.

  14. Experimental Test of Alternating-Current Zeeman Interference Effect in Ramsey Separated Oscillating Fields

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jun-Hai; WANG Feng-Zhi; YANG Dong-Hai

    2004-01-01

    An experimental test of ac Zeeman effect in an optically pumped caesium beam frequency standard is reported and analysed. An interference pattern of the atomic energy level shift as a function of the applied microwave field near the atomic transition frequency was observed. It was superimposed on the dispersion lineshape of a normal ac Zeeman effect. This effect was analysed with the atomic wavefunction phase analysing method.

  15. Experimental test of the Gallavotti-Cohen fluctuation theorem in turbulent flows

    Science.gov (United States)

    Ciliberto, S.; Garnier, N.; Hernandez, S.; Lacpatia, C.; Pinton, J.-F.; Ruiz Chavarria, G.

    2004-09-01

    We test the fluctuation theorem from measurements in turbulent flows. We study the time fluctuations of the force acting on an obstacle, and we consider two experimental situations: the case of a von Kármán swirling flow between counter-rotating disks and the case of a wind tunnel jet. We first study the symmetries implied by the Gallavotti-Cohen fluctuation theorem (FT) on the probability density distributions of the force fluctuations; we then test the Sinai scaling. We observe that in both experiments the symmetries implied by the FT are well verified, whereas the Sinai scaling is established, as expected, only for long times.

  16. The experimental determination of atmospheric absorption from aircraft acoustic flight tests

    Science.gov (United States)

    Miller, R. L.; Oncley, P. B.

    1971-01-01

    A method for determining atmospheric absorption coefficients from acoustic flight test data is presented. Measurements from five series of acoustic flight tests were included in the study. The number of individual flights totaled 24: six Boeing 707 flights performed in May 1969 in connection with the turbofan nacelle modification program, eight flights from Boeing tests conducted during the same period, and 10 flights of the Boeing 747 airplane. The effects of errors in acoustic, meteorological, and aircraft performance and position measurements are discussed. Tabular data of the estimated sample variance of the data for each test are given for source directivity angles from 75 deg to 120 deg and each 1/3-octave frequency band. Graphic comparisons are made of absorption coefficients derived from ARP 866, using atmospheric profile data, with absorption coefficients determined by the experimental method described in the report.

  17. Experimental study on the flight dynamics of a bioinspired ornithopter: free flight testing and wind tunnel testing

    Science.gov (United States)

    Lee, Jun-Seong; Han, Jae-Hung

    2012-09-01

    This study experimentally shows the flight dynamics of a bioinspired ornithopter using two different types of approach: (1) free flight testing, and (2) wind tunnel testing. An ornithopter is flown in straight and level flight with a fixed wingbeat frequency and tail elevation angle. A three-dimensional visual tracking system is applied to follow the retro-reflective markers on the ornithopter and record the flight trajectories. The unique oscillatory behavior of the body in the longitudinal plane is observed in the free flight testing and the detailed wing and tail deformations are also obtained. Based on the trim flight data, a specially devised tether device is designed and employed to emulate the free flight conditions in the wind tunnel. The tether device provides minimal mechanical interference and longitudinal flight dynamic characteristics similar to those of free flight. On introducing a pitching moment disturbance to the body, the oscillation recovered to the original trajectory turns out to be a stable limit-cycle oscillation (LCO). During the wind tunnel testing, the magnitude of LCO is effectively suppressed by active tail motion.

  18. Development of a Marslander with crushable shock absorber by virtual and experimental testing

    Science.gov (United States)

    Schröder, Silvio; Reinhardt, B.; Brauner, C.; Gebauer, I.; Buchwald, R.

    2017-05-01

    Since the beginning of space exploration, probes have been sent to other planets or moons with the associated challenge of landing on these bodies. For a soft landing several damping methods like landing legs or airbags have been used. A new and potentially less complex and lighter way to reduce the shock loads at touchdown is the use of a crushable shield underneath the lander platform. This crushable shield could be made for example out of an energy absorbing materials like an aluminum honeycomb core with a High Performance Polyethylene cover sheet. The design is particularly advantageous since no moving parts nor other mechanisms are required, thus making the shield very robust and fail safe. The only mission that has used this technique is the ESA/Roscosmos-mission ;ExoMars; which started in 2016. The development of such a crushable shock absorber implies and requires assessment of materials, manufacturing processes, the setup of a numerical simulation and the experimental validation in a test lab. In an independent research project (Marslander) a representative engineering mockup of the landing platform has been built and tested at the Landing & Mobility Test Facility (LAMA) to support the numerical simulation model with experimental data. This paper is focusing on the hardware tests. Results of the above stated development and testing processes will be presented and discussed.

  19. Experimental Test of Stainless Steel Wire Mesh and Aluminium Alloy With Glass Fiber Reinforcement Hybrid Composite

    Directory of Open Access Journals (Sweden)

    Ranga Raj R.,

    2015-05-01

    Full Text Available At present, composite materials are mostly used in aircraft structural components, because of their excellent properties like lightweight, high strength to weight ratio, high stiffness, and corrosion resistance and less expensive. In this experimental work, the mechanical properties of laminate, this is reinforced with stainless steel wire mesh, aluminum sheet metal, perforated aluminum sheet metal and glass fibers to be laminate and investigated. The stainless steel wire mesh and perforated aluminum metal were sequentially stacked to fabricate, hybrid composites. The aluminum metal sheet is also employed with that sequence to get maximum strength and less weight. The tensile, compressive and flexure tests carried out on the hybrid composite. To investigate the mechanical properties and elastic properties of the metal matrix composite laminate of a material we are using experimental test and theoretical calculation. The experimental work consists of Tensile, compressive and flexural test. The expectation of this project results in the tensile and compressive properties of this hybrid composite it is slightly lesser than carbon fibers but it could facilitate a weight reduction compared with CFRP panels. So this hybrid laminates composite material offering significant weight savings and maximum strength over some other GFRP conventional panels.

  20. Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests

    Directory of Open Access Journals (Sweden)

    Mariane Miyashiro

    2011-06-01

    Full Text Available OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5. RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20 for PU-1, 347.90 MPa (SD=109.54 for PU-2 and 304.64 MPa (SD=25.48 for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.